1
|
Westhölter D, Haubold J, Welsner M, Salhöfer L, Wienker J, Sutharsan S, Straßburg S, Taube C, Umutlu L, Schaarschmidt BM, Koitka S, Zensen S, Forsting M, Nensa F, Hosch R, Opitz M. Elexacaftor/tezacaftor/ivacaftor influences body composition in adults with cystic fibrosis: a fully automated CT-based analysis. Sci Rep 2024; 14:9465. [PMID: 38658613 PMCID: PMC11043331 DOI: 10.1038/s41598-024-59622-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Accepted: 04/11/2024] [Indexed: 04/26/2024] Open
Abstract
A poor nutritional status is associated with worse pulmonary function and survival in people with cystic fibrosis (pwCF). CF transmembrane conductance regulator modulators can improve pulmonary function and body weight, but more data is needed to evaluate its effects on body composition. In this retrospective study, a pre-trained deep-learning network was used to perform a fully automated body composition analysis on chest CTs from 66 adult pwCF before and after receiving elexacaftor/tezacaftor/ivacaftor (ETI) therapy. Muscle and adipose tissues were quantified and divided by bone volume to obtain body size-adjusted ratios. After receiving ETI therapy, marked increases were observed in all adipose tissue ratios among pwCF, including the total adipose tissue ratio (+ 46.21%, p < 0.001). In contrast, only small, but statistically significant increases of the muscle ratio were measured in the overall study population (+ 1.63%, p = 0.008). Study participants who were initially categorized as underweight experienced more pronounced effects on total adipose tissue ratio (p = 0.002), while gains in muscle ratio were equally distributed across BMI categories (p = 0.832). Our findings suggest that ETI therapy primarily affects adipose tissues, not muscle tissue, in adults with CF. These effects are primarily observed among pwCF who were initially underweight. Our findings may have implications for the future nutritional management of pwCF.
Collapse
Affiliation(s)
- Dirk Westhölter
- Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
| | - Johannes Haubold
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Matthias Welsner
- Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
- Adult Cystic Fibrosis Center, Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
| | - Luca Salhöfer
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Johannes Wienker
- Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
| | - Sivagurunathan Sutharsan
- Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
- Adult Cystic Fibrosis Center, Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
| | - Svenja Straßburg
- Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
- Adult Cystic Fibrosis Center, Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
| | - Christian Taube
- Department of Pulmonary Medicine, University Hospital Essen-Ruhrlandklinik, Essen, Germany
| | - Lale Umutlu
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Benedikt M Schaarschmidt
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sven Koitka
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Felix Nensa
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - René Hosch
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Marcel Opitz
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany.
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
| |
Collapse
|
2
|
Wienker J, Darwiche K, Rüsche N, Büscher E, Karpf-Wissel R, Winantea J, Özkan F, Westhölter D, Taube C, Kersting D, Hautzel H, Salhöfer L, Hosch R, Nensa F, Forsting M, Schaarschmidt BM, Zensen S, Theysohn J, Umutlu L, Haubold J, Opitz M. Body composition impacts outcome of bronchoscopic lung volume reduction in patients with severe emphysema: a fully automated CT-based analysis. Sci Rep 2024; 14:8718. [PMID: 38622275 PMCID: PMC11018765 DOI: 10.1038/s41598-024-58628-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 04/01/2024] [Indexed: 04/17/2024] Open
Abstract
Chronic Obstructive Pulmonary Disease (COPD) is characterized by progressive and irreversible airflow limitation, with individual body composition influencing disease severity. Severe emphysema worsens symptoms through hyperinflation, which can be relieved by bronchoscopic lung volume reduction (BLVR). To investigate how body composition, assessed through CT scans, impacts outcomes in emphysema patients undergoing BLVR. Fully automated CT-based body composition analysis (BCA) was performed in patients with end-stage emphysema receiving BLVR with valves. Post-interventional muscle and adipose tissues were quantified, body size-adjusted, and compared to baseline parameters. Between January 2015 and December 2022, 300 patients with severe emphysema underwent endobronchial valve treatment. Significant improvements were seen in outcome parameters, which were defined as changes in pulmonary function, physical performance, and quality of life (QoL) post-treatment. Muscle volume remained stable (1.632 vs. 1.635 for muscle bone adjusted ratio (BAR) at baseline and after 6 months respectively), while bone adjusted adipose tissue volumes, especially total and pericardial adipose tissue, showed significant increase (2.86 vs. 3.00 and 0.16 vs. 0.17, respectively). Moderate to strong correlations between bone adjusted muscle volume and weaker correlations between adipose tissue volumes and outcome parameters (pulmonary function, QoL and physical performance) were observed. Particularly after 6-month, bone adjusted muscle volume changes positively corresponded to improved outcomes (ΔForced expiratory volume in 1 s [FEV1], r = 0.440; ΔInspiratory vital capacity [IVC], r = 0.397; Δ6Minute walking distance [6MWD], r = 0.509 and ΔCOPD assessment test [CAT], r = -0.324; all p < 0.001). Group stratification by bone adjusted muscle volume changes revealed that groups with substantial muscle gain experienced a greater clinical benefit in pulmonary function improvements, QoL and physical performance (ΔFEV1%, 5.5 vs. 39.5; ΔIVC%, 4.3 vs. 28.4; Δ6MWDm, 14 vs. 110; ΔCATpts, -2 vs. -3.5 for groups with ΔMuscle, BAR% < -10 vs. > 10, respectively). BCA results among patients divided by the minimal clinically important difference for forced expiratory volume of the first second (FEV1) showed significant differences in bone-adjusted muscle and intramuscular adipose tissue (IMAT) volumes and their respective changes after 6 months (ΔMuscle, BAR% -5 vs. 3.4 and ΔIMAT, BAR% -0.62 vs. 0.60 for groups with ΔFEV1 ≤ 100 mL vs > 100 mL). Altered body composition, especially increased muscle volume, is associated with functional improvements in BLVR-treated patients.
Collapse
Affiliation(s)
- Johannes Wienker
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany.
| | - Kaid Darwiche
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany
| | - Nele Rüsche
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany
| | - Erik Büscher
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany
| | - Rüdiger Karpf-Wissel
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany
| | - Jane Winantea
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany
| | - Filiz Özkan
- Division of Interventional Pneumology, Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Tüschener Weg 40, 45239, Essen, Germany
| | - Dirk Westhölter
- Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Essen, Germany
| | - Christian Taube
- Department of Pulmonary Medicine, University Medicine Essen-Ruhrlandklinik, Essen, Germany
| | - David Kersting
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Hubertus Hautzel
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Luca Salhöfer
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - René Hosch
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
| | - Felix Nensa
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Benedikt M Schaarschmidt
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Jens Theysohn
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Lale Umutlu
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Johannes Haubold
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Marcel Opitz
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| |
Collapse
|
3
|
Kroll L, Schlosser T, Zensen S. [Unveiling Hidden Dangers: A Case of Retained Surgical Foreign Body after David's Procedure and the Quest for Automated Detection]. ROFO-FORTSCHR RONTG 2024. [PMID: 38395053 DOI: 10.1055/a-2254-5602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Affiliation(s)
- Lennard Kroll
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Thomas Schlosser
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| |
Collapse
|
4
|
Hlouschek J, König B, Bos D, Santiago A, Zensen S, Haubold J, Pöttgen C, Herz A, Opitz M, Wetter A, Guberina M, Stuschke M, Zylka W, Kühl H, Guberina N. Experimental Examination of Conventional, Semi-Automatic, and Automatic Volumetry Tools for Segmentation of Pulmonary Nodules in a Phantom Study. Diagnostics (Basel) 2023; 14:28. [PMID: 38201337 PMCID: PMC10804383 DOI: 10.3390/diagnostics14010028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 12/10/2023] [Accepted: 12/17/2023] [Indexed: 01/12/2024] Open
Abstract
The aim of this study is to examine the precision of semi-automatic, conventional and automatic volumetry tools for pulmonary nodules in chest CT with phantom N1 LUNGMAN. The phantom is a life-size anatomical chest model with pulmonary nodules representing solid and subsolid metastases. Gross tumor volumes (GTVis) were contoured using various approaches: manually (0); as a means of semi-automated, conventional contouring with (I) adaptive-brush function; (II) flood-fill function; and (III) image-thresholding function. Furthermore, a deep-learning algorithm for automatic contouring was applied (IV). An intermodality comparison of the above-mentioned strategies for contouring GTVis was performed. For the mean GTVref (standard deviation (SD)), the interquartile range (IQR)) was 0.68 mL (0.33; 0.34-1.1). GTV segmentation was distributed as follows: (I) 0.61 mL (0.27; 0.36-0.92); (II) 0.41 mL (0.28; 0.23-0.63); (III) 0.65 mL (0.35; 0.32-0.90); and (IV) 0.61 mL (0.29; 0.33-0.95). GTVref was found to be significantly correlated with GTVis (I) p < 0.001, r = 0.989 (III) p = 0.001, r = 0.916, and (IV) p < 0.001, r = 0.986, but not with (II) p = 0.091, r = 0.595. The Sørensen-Dice indices for the semi-automatic tools were 0.74 (I), 0.57 (II) and 0.71 (III). For the semi-automatic, conventional segmentation tools evaluated, the adaptive-brush function (I) performed closest to the reference standard (0). The automatic deep learning tool (IV) showed high performance for auto-segmentation and was close to the reference standard. For high precision radiation therapy, visual control, and, where necessary, manual correction, are mandatory for all evaluated tools.
Collapse
Affiliation(s)
- Julian Hlouschek
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Britta König
- Department of Radiology, University Hospital Muenster (UKM), Albert-Schweitzer-Campus 1, Gebäude A1, 48149 Muenster, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Alina Santiago
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Christoph Pöttgen
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Andreas Herz
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Axel Wetter
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Eißendorfer Pferdeweg 52, 21075 Hamburg, Germany
| | - Maja Guberina
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Martin Stuschke
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Waldemar Zylka
- Westphalian University, Campus Gelsenkirchen, Neidenburger Str. 43, 45897 Gelsenkirchen, Germany
| | - Hilmar Kühl
- Department of Radiology, St. Bernhard-Hospital Kamp-Lintfort, Bürgermeister-Schmelzing-Str. 90, 47475 Kamp-Lintfort, Germany
| | - Nika Guberina
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| |
Collapse
|
5
|
Zensen S, Bücker A, Meetschen M, Haubold J, Opitz M, Theysohn JM, Schramm S, Jochheim L, Kasper S, Forsting M, Schaarschmidt BM. Current use of percutaneous image-guided tumor ablation for the therapy of liver tumors: lessons learned from the registry of the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) 2018-2022. Eur Radiol 2023:10.1007/s00330-023-10412-w. [PMID: 37935847 DOI: 10.1007/s00330-023-10412-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 08/31/2023] [Accepted: 10/05/2023] [Indexed: 11/09/2023]
Abstract
OBJECTIVES Percutaneous image-guided tumor ablation of liver malignancies has become an indispensable therapeutic procedure. The aim of this evaluation of the prospectively managed multinational registry of the voluntary German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) was to analyze its use, technical success, and complications in clinical practice. MATERIALS AND METHODS All liver tumor ablations from 2018 to 2022 were included. Technical success was defined as complete ablation of the tumor with an ablative margin. RESULTS A total of 7228 liver tumor ablations from 136 centers in Germany and Austria were analyzed. In total, 31.4% (2268/7228) of patients were female. Median age was 67 years (IQR 58-74 years). Microwave ablation (MWA) was performed in 65.1% (4703/7228), and radiofrequency ablation (RFA) in 32.7% (2361/7228). Of 5229 cases with reported tumor etiology, 60.3% (3152/5229) of ablations were performed for liver metastases and 37.3% (1950/5229) for hepatocellular carcinoma. The median lesion diameter was 19 mm (IQR 12-27 mm). In total, 91.8% (6636/7228) of ablations were technically successful. The rate of technically successful ablations was significantly higher in MWA (93.9%, 4417/4703) than in RFA (87.3%, 2061/2361) (p < 0.0001). The total complication rate was 3.0% (214/7228) and was significantly higher in MWA (4.0%, 189/4703) than in RFA (0.9%, 21/2361, p < 0.0001). Additional needle track ablation did not increase the rate of major complications significantly (24.8% (33/133) vs. 28.4% (23/81), p = 0.56)). CONCLUSION MWA is the most frequent ablation method. Percutaneous image-guided liver tumor ablations have a high technical success rate, which is higher for MWA than RFA. The complication rate is generally low but is higher for MWA than RFA. CLINICAL RELEVANCE STATEMENT Percutaneous image-guided liver ablation using microwave ablation and radiofrequency ablation are effective therapeutic procedures with low complication rates for the treatment of primary and secondary liver malignancies. KEY POINTS • Percutaneous image-guided liver tumor ablations have a high technical success rate, which is higher for microwave ablation than radiofrequency ablation. • Microwave ablation is the most frequent ablation method ahead of radiofrequency ablation. • The complication rate is generally low but is higher for microwave ablation than radiofrequency ablation.
Collapse
Affiliation(s)
- Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
| | - Arno Bücker
- Department of Diagnostic and Interventional Radiology, University Hospital Homburg/Saar, Homburg, Germany
| | - Mathias Meetschen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Jens M Theysohn
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sara Schramm
- Institute for Medical Informatics, Biometry, and Epidemiology, University Hospital Essen, Essen, Germany
| | - Leonie Jochheim
- Department of Gastroenterology and Hepatology, University Hospital Essen, Essen, Germany
| | - Stefan Kasper
- West German Cancer Center, Department of Medical Oncology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | | |
Collapse
|
6
|
Meetschen M, Bücker A, Nikolaou K, Salhöfer L, Zensen S, Schaarschmidt BM, Wetter A, Haubold J. Complications Of Image-Guided Drainage. Dtsch Arztebl Int 2023; 120:553-554. [PMID: 37732592 PMCID: PMC10546882 DOI: 10.3238/arztebl.m2023.0140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 05/23/2023] [Accepted: 05/23/2023] [Indexed: 09/22/2023]
Affiliation(s)
- Mathias Meetschen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Arno Bücker
- Department of Diagnostic and Interventional Radiology, Saarland University Hospital, Homburg, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Luca Salhöfer
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Benedikt M. Schaarschmidt
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Axel Wetter
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Hamburg, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| |
Collapse
|
7
|
Haubold J, Zensen S, Hosch R, Schaarschmidt BM, Bos D, Schmidt B, Flohr T, Li Y, Forsting M, Pietsch H, Nensa F, Jost G. Individualized scan protocols for CT angiography: an animal study for contrast media or radiation dose optimization. Eur Radiol Exp 2023; 7:24. [PMID: 37185930 PMCID: PMC10130261 DOI: 10.1186/s41747-023-00332-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 02/16/2023] [Indexed: 05/17/2023] Open
Abstract
BACKGROUND We investigated about optimization of contrast media (CM) dose or radiation dose in thoracoabdominal computed tomography angiography (CTA) by automated tube voltage selection (ATVS) system configuration and CM protocol adaption. METHODS In six minipigs, CTA-optimized protocols were evaluated regarding objective (contrast-to-noise ratio, CNR) and subjective (6 criteria assessed by Likert scale) image quality. Scan parameters were automatically adapted by the ATVS system operating at 90-kV semi-mode and configured for standard, CM saving, or radiation dose saving (image task, quality settings). Injection protocols (dose, flow rate) were adapted manually. This approach was tested for normal and simulated obese conditions. RESULTS Radiation exposure (volume-weighted CT dose index) for normal (obese) conditions was 2.4 ± 0.7 (5.0 ± 0.7) mGy (standard), 4.3 ± 1.1 (9.0 ± 1.3) mGy (CM reduced), and 1.7 ± 0.5 (3.5 ± 0.5) mGy (radiation reduced). The respective CM doses for normal (obese) settings were 210 (240) mgI/kg, 155 (177) mgI/kg, and 252 (288) mgI/kg. No significant differences in CNR (normal; obese) were observed between standard (17.8 ± 3.0; 19.2 ± 4.0), CM-reduced (18.2 ± 3.3; 20.5 ± 4.9), and radiation-saving CTAs (16.0 ± 3.4; 18.4 ± 4.1). Subjective analysis showed similar values for optimized and standard CTAs. Only the parameter diagnostic acceptability was significantly lower for radiation-saving CTA compared to the standard CTA. CONCLUSIONS The CM dose (-26%) or radiation dose (-30%) for thoracoabdominal CTA can be reduced while maintaining objective and subjective image quality, demonstrating the feasibility of the personalization of CTA scan protocols. KEY POINTS • Computed tomography angiography protocols could be adapted to individual patient requirements using an automated tube voltage selection system combined with adjusted contrast media injection. • Using an adapted automated tube voltage selection system, a contrast media dose reduction (-26%) or radiation dose reduction (-30%) could be possible.
Collapse
Affiliation(s)
- Johannes Haubold
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany.
| | - Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
| | - René Hosch
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
- Institute of Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
| | - Benedikt Michael Schaarschmidt
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
| | - Denise Bos
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
| | | | | | - Yan Li
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
| | - Michael Forsting
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
| | | | - Felix Nensa
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147, Essen, Germany
- Institute of Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany
| | - Gregor Jost
- MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| |
Collapse
|
8
|
Haubold J, Zeng K, Farhand S, Stalke S, Steinberg H, Bos D, Meetschen M, Kureishi A, Zensen S, Goeser T, Maier S, Forsting M, Nensa F. AI co-pilot: content-based image retrieval for the reading of rare diseases in chest CT. Sci Rep 2023; 13:4336. [PMID: 36928759 PMCID: PMC10020154 DOI: 10.1038/s41598-023-29949-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 02/13/2023] [Indexed: 03/18/2023] Open
Abstract
The aim of the study was to evaluate the impact of the newly developed Similar patient search (SPS) Web Service, which supports reading complex lung diseases in computed tomography (CT), on the diagnostic accuracy of residents. SPS is an image-based search engine for pre-diagnosed cases along with related clinical reference content ( https://eref.thieme.de ). The reference database was constructed using 13,658 annotated regions of interest (ROIs) from 621 patients, comprising 69 lung diseases. For validation, 50 CT scans were evaluated by five radiology residents without SPS, and three months later with SPS. The residents could give a maximum of three diagnoses per case. A maximum of 3 points was achieved if the correct diagnosis without any additional diagnoses was provided. The residents achieved an average score of 17.6 ± 5.0 points without SPS. By using SPS, the residents increased their score by 81.8% to 32.0 ± 9.5 points. The improvement of the score per case was highly significant (p = 0.0001). The residents required an average of 205.9 ± 350.6 s per case (21.9% increase) when SPS was used. However, in the second half of the cases, after the residents became more familiar with SPS, this increase dropped to 7%. Residents' average score in reading complex chest CT scans improved by 81.8% when the AI-driven SPS with integrated clinical reference content was used. The increase in time per case due to the use of the SPS was minimal.
Collapse
Affiliation(s)
- Johannes Haubold
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.
- Institute of Artificial Intelligence in Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.
| | - Ke Zeng
- Siemens Medical Solutions Inc., Malvern, PA, USA
| | | | | | - Hannah Steinberg
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Denise Bos
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Mathias Meetschen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Anisa Kureishi
- Institute of Artificial Intelligence in Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Tim Goeser
- Department of Radiology and Neuroradiology, Kliniken Maria Hilf, Viersener Str. 450, 41063, Mönchengladbach, NRW, Germany
| | - Sandra Maier
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Michael Forsting
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Felix Nensa
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
- Institute of Artificial Intelligence in Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| |
Collapse
|
9
|
Bos D, Guberina N, Zensen S, Opitz M, Forsting M, Wetter A. Radiation Exposure in Computed Tomography. Dtsch Arztebl Int 2023; 120:135-141. [PMID: 36633449 DOI: 10.3238/arztebl.m2022.0395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 04/13/2022] [Accepted: 12/05/2022] [Indexed: 01/13/2023]
Abstract
BACKGROUND Computed tomography (CT) studies are requested by specialists from most medical disciplines and play a vital role in the diagnosis and treatment of patients. It follows that physicians of all specialties should possess basic knowledge of computed tomography, its proper use, and the radiation exposure associated with it. METHODS This review is based on publications retrieved by a selective search of the literature. RESULTS Approximately 12 million CT studies are carried out in Germany each year, and the trend is rising. Approximately 9% of all diagnostic studies involving ionizing radiation are CT studies. On average, more than 60% of the collective effective dose due to medical radiation exposure is attributable to CT. There are two types of radiation effects caused by ionizing radiation: stochastic and deterministic. The additional, individual relative lifetime cancer mortality risk due to ionizing radiation with whole-body exposure at a low single dose is estimated at 5% per sievert. Radiation exposure from CT studies of the head and trunk, e.g. of a patient with polytrauma, corresponds to an additional lifetime cancer mortality risk of approximately 0.1% at an effective dose of approximately 20 millisievert. CONCLUSION The radiation exposure due to CT, and the risks to which patients are subjected by it, have become more important with greater use of CT. Technical advances, targeted dose monitoring, and analyses of dose data can help identify areas where improvement is necessary, in furtherance of the overriding goal of lowering patients' radiation exposure while preserving adequate image quality.
Collapse
|
10
|
Opitz M, Zensen S, Ludwig JM, Weber M, Alatzides G, Seifert R, Grüneisen J, Theysohn JM, Bos D, Schaarschmidt BM. Radiation dose aspects and establishment of diagnostic reference levels for 90Y radioembolisation during angiographic procedure. J Radiol Prot 2022; 42:031518. [PMID: 36067741 DOI: 10.1088/1361-6498/ac8f9e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 09/06/2022] [Indexed: 06/15/2023]
Abstract
90Y radioembolisation (RE) is an angiographic procedure used in patients with both primary and secondary hepatic malignancies. Local tumour control can be achieved by short range tumour irradiation by the regional intra-arterial administration of glass or resin microspheres loaded with 90yttrium that accumulate in the tumorous tissue. The aim of this study was to investigate the radiation exposure of RE and to establish a local diagnostic reference level (DRL). In this retrospective study, dose data from 397 procedures in 306 patients (mean age 67.4 ± 10.6 years, 82 female) who underwent RE between 06/2017 and 01/2022 using one of two different angiography systems were analysed. DRL was set as the 75th percentile of the dose distribution. In the overall population, dose area product (DAP) (median (interquartile range, IQR)) was 26 Gy cm2(IQR 12-50) with a median fluoroscopy time (FT) of 4.5 min (IQR 2.9-8.0). FT and DAP increased significantly with the number of infusion positions (median, IQR): one position 23 Gy cm2(12-46), two positions 33 Gy cm2(14-60), three positions 50 Gy cm2(24-82) (p< 0.0001). Local DRL is 47 Gy cm2for RE and 111 Gy cm2for RE with additional embolisation. Radiation exposure and FT are significantly higher with increasing number of infusion positions as well as additional embolisation. Our established DRLs for RE may serve as a benchmark for dose optimisation.
Collapse
Affiliation(s)
- Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Johannes Maximilian Ludwig
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Manuel Weber
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
- West German Cancer Center, University Hospital Essen, Essen, Germany
- German Cancer Consortium (DKTK), University Hospital Essen, Essen, Germany
| | - Georgios Alatzides
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Robert Seifert
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
- West German Cancer Center, University Hospital Essen, Essen, Germany
- German Cancer Consortium (DKTK), University Hospital Essen, Essen, Germany
| | - Johannes Grüneisen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Jens Matthias Theysohn
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| | - Benedikt Michael Schaarschmidt
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147 Essen, Germany
| |
Collapse
|
11
|
Bos D, Zensen S, Opitz M, Nassenstein K, Kinner S, Schweiger B, Forsting M, Wetter A, Guberina N, Haubold J. Diagnostische Referenzwerte von Computertomographien des Thorax bei Kindern in Abhängigkeit von Patientengröße und Alter. ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- D Bos
- Universitätsklinikum Essen, Institut f. Diagn. u. Interv. Radiologie u. Neuroradiologie, Essen
| | - S Zensen
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - M Opitz
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - K Nassenstein
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - S Kinner
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - B Schweiger
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - M Forsting
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - A Wetter
- Klinik für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Asklepios Klinikum Harburg, Hamburg
| | - N Guberina
- Klinik für Strahlentherapie, Universitätsklinikum Essen, Essen
| | - J Haubold
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| |
Collapse
|
12
|
Meetschen M, Haubold J, Zeng K, Farhand S, Stalke S, Steinberg H, Bos D, Kureishi A, Zensen S, Goeser T, Maier S, Forsting M, Umutlu L, Nensa F. KI als Co-Pilot: Inhaltsbasierte Bildsuche zur Erkennung seltener Krankheiten in der Thorax-CT. ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- M Meetschen
- Uniklinik Essen, Institut für Diagnostische und Interventionelle Radiologie u, Essen
| | - J Haubold
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - K Zeng
- Siemens Medical Solutions Inc., Malvern, PA
| | - S Farhand
- Siemens Medical Solutions Inc., Malvern, PA
| | - S Stalke
- Georg Thieme Verlag KG, Stuttgart
| | - H Steinberg
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Essen, Universitätsklinikum Essen, Essen
| | - D Bos
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - A Kureishi
- Institut für Künstliche Intelligenz in der Medizin, Universitätsklinikum Essen, Essen
| | - S Zensen
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - T Goeser
- Radiologie und Neuroradiologie, Kliniken Maria Hilf GmbH, Mönchengladbach
| | - S Maier
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - M Forsting
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - L Umutlu
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen, Essen
| | - F Nensa
- Institut für Künstliche Intelligenz in der Medizin, Universitätsklinikum Essen, Essen
| |
Collapse
|
13
|
Zensen S, Opitz MK, Grueneisen JS, Li Y, Haubold J, Steinberg HL, Forsting M, Theysohn JM, Bos D, Schaarschmidt BM. Radiation exposure, organ and effective dose of CT-guided liver biopsy as a function of lesion depth and size. J Radiol Prot 2022; 42:031505. [PMID: 35790148 DOI: 10.1088/1361-6498/ac7e80] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
Computed tomography (CT)-guided percutaneous biopsies play an important role in the diagnostic workup of liver lesions. Because radiation dose accumulates rapidly due to repeated image acquisition in a relatively small scan area, analysing radiation exposure is critical for improving radiation protection of CT-guided interventions. The aim of this study was to assess the radiation dose of CT-guided liver biopsies and the influence of lesion parameters, and to establish a local diagnostic reference level (DRL). In this observational retrospective cohort study, dose data of 60 CT-guided liver biopsies between September 2016 and July 2017 were analysed. Radiation exposure was reported for volume-weighted CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose-length product (DLP) and effective dose (ED). Radiation dose of CT-guided liver biopsy was (median (interquartile range)): CTDIvol9.91 mGy (8.33-11.45 mGy), SSDE 10.42 mGy (9.39-11.70 mGy), DLP 542 mGy cm (410-733 mGy cm), ED 8.52 mSv (7.17-13.25 mSv). Radiation exposure was significantly higher in biopsies of deep liver lesions compared to superficial lesions (DLP 679 ± 285 mGy cm vs. 497 ± 167 mGy cm,p= 0.0046). No significant dose differences were observed for differences in lesion or needle size. With helical CT spirals additional to the biopsy-guiding axial CT scans, radiation exposure was significantly increased: 797 ± 287 mGy cm vs. 495 ± 162 mGy cm,p< 0.0001. The local DRL is CTDIvol9.91 mGy, DLP 542 mGy cm. Radiation dose is significantly increased in biopsies of deeper liver lesions compared with superficial lesions. Interventions with additional biopsy-guiding CT spirals lead to higher radiation doses. This study provides a detailed analysis of local radiation doses for CT-guided liver biopsies and provides a benchmark for optimising radiation protection in interventional radiology.
Collapse
Affiliation(s)
- Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Marcel Klaus Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Johannes Stefan Grueneisen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Yan Li
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Hannah Louisa Steinberg
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Jens Matthias Theysohn
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| | - Benedikt Michael Schaarschmidt
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, Essen, 45147, Germany
| |
Collapse
|
14
|
Zensen S, Nassenstein K, Horn D. Liver Laceration Secondary to Resuscitation. Dtsch Arztebl Int 2022; 119:417. [PMID: 36106875 PMCID: PMC9533705 DOI: 10.3238/arztebl.m2022.0018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Affiliation(s)
- Sebastian Zensen
- *Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen,
| | - Kai Nassenstein
- *Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen,
| | - Detlef Horn
- **Klinik für Allgemein-, Viszeral- und Unfallchirurgie, Elisabeth-Krankenhaus Essen
| |
Collapse
|
15
|
Zensen S, Opitz MK, Ludwig JM, Haubold J, Richly H, Siveke JT, Theysohn JM, Forsting M, Bos D, Schaarschmidt BM. Radiation Dose Aspects of Hepatic Artery Infusion Chemotherapy in Uveal Melanoma Patients with Liver Metastases. Cardiovasc Intervent Radiol 2022; 45:841-845. [PMID: 35437708 PMCID: PMC9117360 DOI: 10.1007/s00270-022-03130-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 03/19/2022] [Indexed: 12/03/2022]
Abstract
Purpose In uveal melanoma patients, liver metastases can be treated by hepatic artery infusion chemotherapy (HAIC). During this procedure, melphalan or, less frequently, fotemustine is infused into the hepatic artery or the hepatic lobe arteries in regularly repeated interventions to achieve local tumor control. The aim of this study was to investigate the radiation exposure of HAIC. Material and methods In this retrospective study, dose data from 841 procedures in 140 patients (mean age 65.3 ± 9.9 years, 74 female) who underwent HAIC between 06/2017 and 10/2021 at one of three different angiography systems were analyzed. Results In the overall population, dose area product (DAP) (median (IQR)) was 1773 cGy·cm2 (884–3688). DAP was significantly higher in the first intervention, where a complete diagnostic workup of the vasculature was performed, than in follow-up interventions: 5765 cGy·cm2 (3160–8804) versus 1502 cGy·cm2 (807–2712) (p < 0.0001). DAP also increased significantly with the number of infusion positions (median, (IQR)): one position 1301 cGy·cm2 (633–2717), two positions 1985 cGy·cm2 (1118–4074), three positions 6407 cGy·cm2 (2616–11590) (p < 0.0001). Conclusion In uveal melanoma patients with liver metastases undergoing HAIC, radiation exposure is significantly higher both at the first intervention compared to follow-up interventions, but also with increasing number of infusion positions. Level of evidence: 3
Collapse
Affiliation(s)
- Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.
| | - Marcel K Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Johannes M Ludwig
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Heike Richly
- Department of Medical Oncology, West German Cancer Center, University of Duisburg-Essen, Essen, Germany
| | - Jens T Siveke
- Bridge Institute of Experimental Tumor Therapy, West German Cancer Center, University Medicine Essen, Essen, Germany.,Division of Solid Tumor Translational Oncology, German Cancer Research Center (DKFZ) and German Cancer Consortium (DKTK), Partner Site Essen, Heidelberg, Germany
| | - Jens M Theysohn
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Benedikt M Schaarschmidt
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| |
Collapse
|
16
|
Zensen S, Bos D, Opitz M, Haubold J, Forsting M, Guberina N, Wetter A. Radiation exposure and establishment of diagnostic reference levels of whole-body low-dose CT for the assessment of multiple myeloma with second- and third-generation dual-source CT. Acta Radiol 2022; 63:527-535. [PMID: 33745295 DOI: 10.1177/02841851211003287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND In the assessment of diseases causing skeletal lesions such as multiple myeloma (MM), whole-body low-dose computed tomography (WBLDCT) is a sensitive diagnostic imaging modality, which has the potential to replace the conventional radiographic survey. PURPOSE To optimize radiation protection and examine radiation exposure, and effective and organ doses of WBLDCT using different modern dual-source CT (DSCT) devices, and to establish local diagnostic reference levels (DRL). MATERIAL AND METHODS In this retrospective study, 281 WBLDCT scans of 232 patients performed between January 2017 and April 2020 either on a second- (A) or third-generation (B) DSCT device could be included. Radiation exposure indices and organ and effective doses were calculated using a commercially available automated dose-tracking software based on Monte-Carlo simulation techniques. RESULTS The radiation exposure indices and effective doses were distributed as follows (median, interquartile range): (A) second-generation DSCT: volume-weighted CT dose index (CTDIvol) 1.78 mGy (1.47-2.17 mGy); dose length product (DLP) 282.8 mGy·cm (224.6-319.4 mGy·cm), effective dose (ED) 1.87 mSv (1.61-2.17 mSv) and (B) third-generation DSCT: CTDIvol 0.56 mGy (0.47-0.67 mGy), DLP 92.0 mGy·cm (73.7-107.6 mGy·cm), ED 0.61 mSv (0.52-0.69 mSv). Radiation exposure indices and effective and organ doses were significantly lower with third-generation DSCT (P < 0.001). Local DRLs could be set for CTDIvol at 0.75 mGy and DLP at 120 mGy·cm. CONCLUSION Third-generation DSCT requires significantly lower radiation dose for WBLDCT than second-generation DSCT and has an effective dose below reported doses for radiographic skeletal surveys. To ensure radiation protection, DRLs regarding WBLDCT are required, where our locally determined values may help as benchmarks.
Collapse
Affiliation(s)
- Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Denise Bos
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Marcel Opitz
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Johannes Haubold
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Michael Forsting
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Nika Guberina
- Department of Radiotherapy, University Hospital Essen, Essen, Germany
| | - Axel Wetter
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| |
Collapse
|
17
|
Müller L, Hahn F, Auer TA, Fehrenbach U, Gebauer B, Haubold J, Zensen S, Kim MS, Eisenblätter M, Diallo TD, Bettinger D, Steinle V, Chang DH, Zopfs D, Pinto Dos Santos D, Kloeckner R. Tumor Burden in Patients With Hepatocellular Carcinoma Undergoing Transarterial Chemoembolization: Head-to-Head Comparison of Current Scoring Systems. Front Oncol 2022; 12:850454. [PMID: 35280804 PMCID: PMC8904349 DOI: 10.3389/fonc.2022.850454] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 01/28/2022] [Indexed: 12/13/2022] Open
Abstract
Objectives Recently, several scoring systems for prognosis prediction based on tumor burden have been promoted for patients with hepatocellular carcinoma (HCC) undergoing transarterial chemoembolization (TACE). This multicenter study aimed to perform the first head-to-head comparison of three scoring systems. Methods We retrospectively enrolled 849 treatment-naïve patients with HCC undergoing TACE at six tertiary care centers between 2010 and 2020. The tumor burden score (TBS), the Six-and-Twelve score (SAT), and the Seven-Eleven criteria (SEC) were calculated based on the maximum lesion size and the number of tumor nodes. All scores were compared in univariate and multivariate regression analyses, adjusted for established risk factors. Results The median overall survival (OS) times were 33.0, 18.3, and 12.8 months for patients with low, medium, and high TBS, respectively (p<0.001). The median OS times were 30.0, 16.9, and 10.2 months for patients with low, medium, and high SAT, respectively (p<0.001). The median OS times were 27.0, 16.7, and 10.5 for patients with low, medium, and high SEC, respectively (p<0.001). In a multivariate analysis, only the SAT remained an independent prognostic factor. The C-Indexes were 0.54 for the TBS, 0.59 for the SAT, and 0.58 for the SEC. Conclusion In a direct head-to-head comparison, the SAT was superior to the TBS and SEC in survival stratification and predictive ability. Therefore, the SAT can be considered when estimating the tumor burden. However, all three scores showed only moderate predictive power. Therefore, tumor burden should only be one component among many in treatment decision making.
Collapse
Affiliation(s)
- Lukas Müller
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Felix Hahn
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Timo Alexander Auer
- Department of Radiology, Charité - University Medicine Berlin, Berlin, Germany
| | - Uli Fehrenbach
- Department of Radiology, Charité - University Medicine Berlin, Berlin, Germany
| | - Bernhard Gebauer
- Department of Radiology, Charité - University Medicine Berlin, Berlin, Germany
| | - Johannes Haubold
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Moon-Sung Kim
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Michel Eisenblätter
- Department of Diagnostic and Interventional Radiology, Freiburg University Hospital, Freiburg, Germany
| | - Thierno D Diallo
- Department of Diagnostic and Interventional Radiology, Freiburg University Hospital, Freiburg, Germany
| | - Dominik Bettinger
- Department of Medicine II, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Verena Steinle
- Department of Diagnostic and Interventional Radiology, University Medical Center Heidelberg, Heidelberg, Germany
| | - De-Hua Chang
- Department of Diagnostic and Interventional Radiology, University Medical Center Heidelberg, Heidelberg, Germany
| | - David Zopfs
- Department of Radiology, University Hospital Cologne, Cologne, Germany
| | | | - Roman Kloeckner
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| |
Collapse
|
18
|
Opitz M, Zensen S, Bos D, Li Y, Styczen H, Wetter A, Guberina N, Jabbarli R, Sure U, Forsting M, Wanke I, Deuschl C. Radiation exposure in the endovascular therapy of cranial and spinal dural arteriovenous fistula in the last decade: a retrospective, single-center observational study. Neuroradiology 2022; 64:587-595. [PMID: 34570252 PMCID: PMC8850286 DOI: 10.1007/s00234-021-02816-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 09/08/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE This study aims to determine local diagnostic reference levels (DRLs) in the endovascular therapy (EVT) of patients with cranial and spinal dural arteriovenous fistula (dAVF). METHODS In a retrospective study design, DRLs and achievable dose (AD) were assessed for all patients with cranial and spinal dAVF undergoing EVT (I) or diagnostic angiography (II). All procedures were performed at the flat-panel angiography-system Allura Xper (Philips Healthcare). Interventional procedures were differentiated according to the region of fistula and the type of procedure. RESULTS In total, 264 neurointerventional procedures of 131 patients with dAVF (94 cranial, 37 spinal) were executed between 02/2010 and 12/2020. The following DRLs, AD, and mean values could be determined: for cranial dAVF (I) DRL 507.33 Gy cm2, AD 369.79 Gy cm2, mean 396.51 Gy cm2; (II) DRL 256.65 Gy cm2, AD 214.19 Gy cm2, mean 211.80 Gy cm2; for spinal dAVF (I) DRL 482.72 Gy cm2, AD 275.98 Gy cm2, mean 347.12 Gy cm2; (II) DRL 396.39 Gy cm2, AD 210.57 Gy cm2, mean 299.55 Gy cm2. Dose levels of EVT were significantly higher compared to diagnostic angiographies (p < 0.001). No statistical difference in dose levels regarding the localization of dAVF was found. CONCLUSION Our results could be used for establishing DRLs in the EVT of cranial and spinal dAVF. Because radiation exposure to comparably complex interventions such as AVM embolization is similar, it may be useful to determine general DRLs for both entities together.
Collapse
Affiliation(s)
- Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany.
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Yan Li
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Hanna Styczen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Hamburg, Germany
| | - Nika Guberina
- Department of Radiotion Therapy, University Hospital Essen, West German Cancer Center, Essen, Germany
| | - Ramazan Jabbarli
- Department of Neurosurgery, University Hospital Essen, Essen, Germany
| | - Ulrich Sure
- Department of Neurosurgery, University Hospital Essen, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Isabel Wanke
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
- Department of Neuroradiology, Clinic Hirslanden, Zurich, Switzerland
| | - Cornelius Deuschl
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| |
Collapse
|
19
|
Opitz M, Zensen S, Breuckmann K, Bos D, Forsting M, Hoffmann O, Stuschke M, Wetter A, Guberina N. Breast Radiation Exposure of 3D Digital Breast Tomosynthesis Compared to Full-Field Digital Mammography in a Clinical Follow-Up Setting. Diagnostics (Basel) 2022; 12:diagnostics12020456. [PMID: 35204547 PMCID: PMC8871344 DOI: 10.3390/diagnostics12020456] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/30/2022] [Accepted: 02/03/2022] [Indexed: 02/04/2023] Open
Abstract
According to a position paper of the European Commission Initiative on Breast Cancer (ECIBC), DBT is close to being introduced in European breast cancer screening programmes. Our study aimed to examine radiation dose delivered by digital breast tomosynthesis (DBT) and digital mammography (FFDM) in comparison to sole FFDM in a clinical follow-up setting and in an identical patient cohort. Retrospectively, 768 breast examinations of 96 patients were included. Patients received both DBT and FFDM between May 2015 and July 2019: (I) FFDM in cranio-caudal (CC) and DBT in mediolateral oblique (MLO) view, as well as a (II) follow-up examination with FFDM in CC and MLO view. The mean glandular dose (MGD) was determined by the mammography system according to Dance’s model. The MGD (standard deviation (SD), interquartile range (IQR)) was distributed as follows: (I) (CCFFDM+MLODBT) (a) left FFDMCC 1.40 mGy (0.36 mGy, 1.13–1.59 mGy), left DBTMLO 1.62 mGy (0.51 mGy, 1.27–1.82 mGy); (b) right FFDMCC 1.36 mGy (0.34 mGy, 1.14–1.51 mGy), right DBTMLO 1.59 mGy (0.52 mGy, 1.27–1.62 mGy). (II) (CCFFDM+MLOFFDM) (a) left FFDMCC 1.35 mGy (0.35 mGy, 1.10–1.60 mGy), left FFDMMLO 1.40 mGy (0.39 mGy, 1.12–1.59 mGy), (b) right FFDMCC 1.35 mGy (0.33 mGy, 1.12–1.48 mGy), right FFDMMLO 1.40 mGy (0.36 mGy, 1.14–1.58 mGy). MGD was significantly higher for DBT mlo views compared to FFDM (p < 0.001). Radiation dose was significantly higher for DBT in MLO views compared to FFDM. However, the MGD of DBT MLO lies below the national diagnostic reference level of 2 mGy for an FFDM view. Hence, our results support the use of either DBT or FFDM as suggested in the ECIBC’s Guidelines.
Collapse
Affiliation(s)
- Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
- Correspondence: (M.O.); (S.Z.)
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
- Correspondence: (M.O.); (S.Z.)
| | - Katharina Breuckmann
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
| | - Oliver Hoffmann
- Department of Obstetrics and Gynecology, University Hospital Essen, 45147 Essen, Germany;
| | - Martin Stuschke
- West German Cancer Center, Department of Radiotherapy, University Hospital Essen, 45147 Essen, Germany;
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, 21075 Hamburg, Germany
| | - Nika Guberina
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, 45147 Essen, Germany; (K.B.); (D.B.); (M.F.); (A.W.); (N.G.)
- West German Cancer Center, Department of Radiotherapy, University Hospital Essen, 45147 Essen, Germany;
| |
Collapse
|
20
|
Opitz M, Zensen S, Bos D, Wetter A, Kleinschnitz C, Uslar E, Jabbarli R, Sure U, Radbruch A, Li Y, Dörner N, Forsting M, Deuschl C, Guberina N. Radiation exposure in the intra-arterial nimodipine therapy of subarachnoid hemorrhage related cerebral vasospasm. J Radiol Prot 2022; 42:011513. [PMID: 34678799 DOI: 10.1088/1361-6498/ac32a2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Accepted: 10/22/2021] [Indexed: 06/13/2023]
Abstract
The selective intra-arterial nimodipine application for the treatment of cerebral vasospasm (CVS) in patients after spontaneous subarachnoid hemorrhage (sSAH) is widely employed. The purpose of this study is to examine the radiation exposure and to determine local diagnostic reference levels (DRLs) of intra-arterial nimodipine therapy. In a retrospective study design, DRLs and achievable dose (AD) were assessed for all patients undergoing (I) selective intra-arterial nimodipine application or (II) additional mechanical angioplasty for CVS treatment. Interventional procedures were differentiated according to the type of procedure and the number of probed vessels. Altogether 494 neurointerventional procedures of 121 patients with CVS due to sSAH could be included. The radiation exposure indices were distributed as follows: (I) DRL 74.3 Gy·cm2, AD 59.8 Gy·cm2; (II) DRL 128.3 Gy·cm2, AD 94.5 Gy·cm2. Kruskal-Wallis test confirmed significant dose difference considering the number of probed vessels (p< 0.001). The mean cumulative dose per patient was 254.9 Gy·cm2(interquartile range 88.6-315.6 Gy·cm2). The DRLs of intra-arterial nimodipine therapy are substantially lower compared with DRLs proposed for other therapeutic interventions, such as thrombectomy or aneurysm coiling. However, repeated therapy sessions are often required, bearing the potential risk of a cumulatively higher radiation exposure.
Collapse
Affiliation(s)
- Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Hamburg, Germany
| | | | - Ellen Uslar
- Department of Neurology, University Hospital Essen, Essen, Germany
| | - Ramazan Jabbarli
- Department of Neurosurgery, University Hospital Essen, Essen, Germany
| | - Ulrich Sure
- Department of Neurosurgery, University Hospital Essen, Essen, Germany
| | | | - Yan Li
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Nils Dörner
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Cornelius Deuschl
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
| | - Nika Guberina
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine University Hospital Essen, Essen, Germany
- Department of Radiation Therapy, University Hospital Essen, West German Cancer Center, Essen, Germany
| |
Collapse
|
21
|
Bos D, Zensen S, Opitz MK, Haubold J, Nassenstein K, Kinner S, Schweiger B, Forsting M, Wetter A, Guberina N. Diagnostic reference levels for chest computed tomography in children as a function of patient size. Pediatr Radiol 2022; 52:1446-1455. [PMID: 35378606 PMCID: PMC9271112 DOI: 10.1007/s00247-022-05340-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 02/11/2022] [Accepted: 02/25/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND Radiation exposures from computed tomography (CT) in children are inadequately studied. Diagnostic reference levels (DRLs) can help optimise radiation doses. OBJECTIVE To determine local DRLs for paediatric chest CT performed mainly on modern dual-source, multi-slice CT scanners as a function of patient size. MATERIALS AND METHODS Five hundred thirty-eight chest CT scans in 345 children under 15 years (y) of age (median age: 8 y, interquartile range [IQR]: 4-13 y) performed on four different CT scanners (38% on third-generation and 43% on second-generation dual-source CT) between November 2013 and December 2020 were retrospectively analysed. Examinations were grouped by water-equivalent diameter as a measure of patient size. DRLs for volume CT dose index (CTDIvol) and dose-length product (DLP) were determined for six different patient sizes and compared to national and European DRLs. RESULTS The DRLs for CTDIvol and DLP are determined for each patient size group as a function of water-equivalent diameter as follows: (I) < 13 cm (n = 22; median: age 7 months): 0.4 mGy, 7 mGy·cm; (II) 13 cm to less than 17 cm (n = 151; median: age 3 y): 1.2 mGy, 25 mGy·cm; (III) 17 cm to less than 21 cm (n = 211; median: age 8 y): 1.7 mGy, 44 mGy·cm; (IV) 21 cm to less than 25 cm (n = 97; median: age 14 y): 3.0 mGy, 88 mGy·cm; (V) 25 cm to less than 29 cm (n = 42; median: age 14 y): 4.5 mGy, 135 mGy·cm; (VI) ≥ 29 cm (n = 15; median: age 14 y): 8.0 mGy, 241 mGy·cm. Compared with corresponding age and weight groups, our size-based DRLs for DLP are 54% to 71% lower than national and 23% to 85% lower than European DRLs. CONCLUSION We developed DRLs for paediatric chest CT as a function of patient size with substantially lower values than national and European DRLs. Precise knowledge of size-based DRLs may assist other institutions in further dose optimisation in children.
Collapse
Affiliation(s)
- Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany.
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Marcel K Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Kai Nassenstein
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Sonja Kinner
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Bernd Schweiger
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Eißendorfer Pferdeweg 52, 21075, Hamburg, Germany
| | - Nika Guberina
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| |
Collapse
|
22
|
Haubold J, Zensen S, Erfanian Y, Guberina N, Opitz M, Sawicki LM, Forsting M, Umutlu L, Theysohn JM. ULTRA-LOW-DOSE COMPUTED TOMOGRAPHY IN UROLITHIASIS-EFFECT OF AN ADDITIONAL TIN FILTER ON IMAGE QUALITY AND RADIATION DOSE. Radiat Prot Dosimetry 2021; 197:146-153. [PMID: 34952539 DOI: 10.1093/rpd/ncab180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 11/12/2021] [Accepted: 12/01/2021] [Indexed: 06/14/2023]
Abstract
To compare radiation dose and image quality of three CT-scanners using optimal dose protocols in patients with suspected urolithiasis regarding additional hardware (tin filter) and software (iterative reconstruction). Examinations from a single-source CT-scanner (A2) and a dual-source CT-scanner (DSCT) (A1) were compared to a tin filter DSCT (B) regarding dose-length product (DLP) and volume-weighted CT dose-index (CTDIvol). DLP of B was 51 and 53% lower in comparison to A1 and A2 (78.62, 159.20 and 165.80 mGy·cm, respectively; P < 0.0001). CTDIvol of B was 53% and 56% significantly lower compared to A1 and A2, respectively (1.52 vs. 3.22 vs. 3.46 mGy; P < 0.0001). Image quality in B proved to be similar to A1 and A2 (3.57, 3.51 and 3.60, respectively; P > 0.05). Inter-rater agreement regarding image quality was good for all CT-scanners (κ = 0.62). Modern CTs with a built-in tin filter allow a significant reduction of radiation exposure in patients with suspected urolithiasis by optimizing the X-ray spectrum.
Collapse
|
23
|
Opitz M, Alatzides G, Zensen S, Bos D, Wetter A, Guberina N, Darkwah Oppong M, Wrede KH, Hagenacker T, Li Y, Wanke I, Forsting M, Deuschl C. Radiation Exposure During Diagnostic and Therapeutic Angiography of Carotid-cavernous Fistula : A Retrospective Single Center Observational Study. Clin Neuroradiol 2021; 32:117-122. [PMID: 34932132 PMCID: PMC8894175 DOI: 10.1007/s00062-021-01126-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 11/17/2021] [Indexed: 11/28/2022]
Abstract
Purpose The aim of this study was to determine local diagnostic reference levels (DRLs) during endovascular diagnostics and therapy of carotid-cavernous fistulas (CCF). Methods In a retrospective study design, DRLs, achievable dose (AD) and mean values were assessed for all patients with CCF undergoing diagnostic angiography (I) or embolization (II). All procedures were performed with the flat-panel angiography system Allura Xper (Philips Healthcare). Interventional procedures were differentiated according to the type of CCF and the type of procedure. Results In total, 86 neurointerventional procedures of 48 patients with CCF were executed between February 2010 and July 2021. The following DRLs, AD and mean values could be determined: (I) DRL 215 Gy ∙ cm2, AD 169 Gy ∙ cm2, mean 165 Gy ∙ cm2; (II) DRL 350 Gy ∙ cm2, AD 226 Gy ∙ cm2, mean 266 Gy ∙ cm2. Dose levels of embolization were significantly higher compared to diagnostic angiography (p < 0.001). No significant dose difference was observed with respect to the type of fistula or the embolization method. Conclusion This article reports on diagnostic and therapeutic DRLs in the management of CCF that could serve as a benchmark for the national radiation protection authorities. Differentiation by fistula type or embolization method does not seem to be useful.
Collapse
Affiliation(s)
- Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.
| | - Georgios Alatzides
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.,Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Hamburg, Germany
| | - Nika Guberina
- Department of Radiation Therapy, University Hospital Essen, West German Cancer Center, Essen, Germany
| | - Marvin Darkwah Oppong
- Department of Neurosurgery and Spine Surgery, University Hospital Essen, Essen, Germany
| | - Karsten H Wrede
- Department of Neurosurgery and Spine Surgery, University Hospital Essen, Essen, Germany
| | - Tim Hagenacker
- Department of Neurology and Center for Translational Neuro- and Behavioral Science (C-TNBS), University Hospital Essen, Essen, Germany
| | - Yan Li
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Isabel Wanke
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.,Department of Neuroradiology, Clinic Hirslanden, Zurich, Switzerland
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Cornelius Deuschl
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, Faculty of Medicine, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany
| |
Collapse
|
24
|
Bos D, Zensen S, Opitz M, Haubold J, Forsting M, Nassenstein K, Guberina N, Wetter A. IMAGE QUALITY STUDY OF RADIATION-REDUCED COMBINED CHEST AND ABDOMEN/PELVIS CT COMPARED WITH A STANDARD PROTOCOL. Radiat Prot Dosimetry 2021; 196:190-198. [PMID: 34635920 DOI: 10.1093/rpd/ncab147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 09/10/2021] [Accepted: 09/15/2021] [Indexed: 06/13/2023]
Abstract
The purpose of this study is to examine radiation doses and image quality of a low-dose (LD) protocol for chest and abdomen/pelvis (CAP) CT compared with a standard (STD) protocol. A total of 361 patients were included between October 2019 and April 2020; 104 patients with LD-protocol (100 kV, ref mAs 80 (chest)/145 (abdomen/pelvis)) and 257 patients with STD-protocol (100 kV, ref mAs 100 (chest)/180 (abdomen/pelvis)) at second-generation dual-source CT. Radiation doses for CTDIvol and DLP, and objective and subjective image qualities of 50 examinations from each group were evaluated. The LD-protocol applied significantly lower radiation doses compared with the STD-protocol (p < 0.001), achieving a dose reduction by 37% for the median DLP in chest, 19% in abdomen/pelvis and 22% in total. Median total DLP was 342 mGy·cm (LD) vs. 436 mGy·cm (STD). The LD-CAP CT protocol achieved a significant dose reduction far below national diagnostic reference levels, ensuring acceptable and good image quality.
Collapse
Affiliation(s)
- Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Kai Nassenstein
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Nika Guberina
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Eißendorfer Pferdeweg 52, 21075 Hamburg, Germany
| |
Collapse
|
25
|
Zensen S, Schlosser T. Gedeckte Ventrikelruptur bei Herzspitzenaneurysma. ROFO-FORTSCHR RONTG 2021; 194:421-422. [PMID: 34736283 DOI: 10.1055/a-1647-3410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany
| | - Thomas Schlosser
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany
| |
Collapse
|
26
|
Bos D, König B, Blex S, Zensen S, Opitz M, Maier S, Forsting M, Zylka W, Kühl H, Wetter A, Guberina N. Experimental examination of radiation doses from cardiac and liver CT perfusion in a phantom study as a function of organ, age and sex. J Radiol Prot 2021; 41:512-525. [PMID: 34406127 DOI: 10.1088/1361-6498/abf71f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Accepted: 04/12/2021] [Indexed: 06/13/2023]
Abstract
Cardiac and liver computed tomography (CT) perfusion has not been routinely implemented in the clinic and requires high radiation doses. The purpose of this study is to examine the radiation exposure and technical settings for cardiac and liver CT perfusion scans at different CT scanners. Two cardiac and three liver CT perfusion protocols were examined with the N1 LUNGMAN phantom at three multi-slice CT scanners: a single-source (I) and second- (II) and third-generation (III) dual-source CT scanners. Radiation doses were reported for the CT dose index (CTDIvol) and dose-length product (DLP) and a standardised DLP (DLP10cm) for cardiac and liver perfusion. The effective dose (ED10cm) for a standardised scan length of 10 cm was estimated using conversion factors based on the International Commission on Radiological Protection (ICRP) 110 phantoms and tissue-weighting factors from ICRP 103. The proposed total lifetime attributable risk of developing cancer was determined as a function of organ, age and sex for adults. Radiation exposure for CTDIvol, DLP/DLP10 cmand ED10 cmduring CT perfusion was distributed as follows: for cardiac perfusion (II) 144 mGy, 1036 mGy·cm/1440 mGy·cm and 39 mSv, and (III) 28 mGy, 295 mGy·cm/279 mGy·cm and 8 mSv; for liver perfusion (I) 225 mGy, 3360 mGy·cm/2249 mGy·cm and 54 mSv, (II) 94 mGy, 1451 mGy·cm/937 mGy·cm and 22 mSv, and (III) 74 mGy, 1096 mGy·cm/739 mGy·cm and 18 mSv. The third-generation dual-source CT scanner applied the lowest doses. Proposed total lifetime attributable risk increased with decreasing age. Even though CT perfusion is a high-dose examination, we observed that new-generation CT scanners could achieve lower doses. There is a strong impact of organ, age and sex on lifetime attributable risk. Further investigations of the feasibility of these perfusion scans are required for clinical implementation.
Collapse
Affiliation(s)
- Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Britta König
- Faculty of Physical Engineering, Westphalian University, Campus Gelsenkirchen, Neidenburger Str. 43, Gelsenkirchen 45897, Germany
| | - Sebastian Blex
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Sandra Maier
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| | - Waldemar Zylka
- Faculty of Physical Engineering, Westphalian University, Campus Gelsenkirchen, Neidenburger Str. 43, Gelsenkirchen 45897, Germany
| | - Hilmar Kühl
- Department of Radiology, St Bernhard-Hospital Kamp-Lintfort GmbH, Bürgermeister-Schmelzing-Str. 90, Kamp-Lintfort 47475, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, 21075 Hamburg, Germany
| | - Nika Guberina
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, 45147 Essen, Germany
| |
Collapse
|
27
|
Bos D, König B, Blex S, Zensen S, Opitz M, Maier S, Forsting M, Zylka W, Kühl H, Wetter A, Guberina N. EXPERIMENTAL EXAMINATION OF RADIATION DOSES OF DUAL- AND SINGLE-ENERGY COMPUTED TOMOGRAPHY IN CHEST AND UPPER ABDOMEN IN A PHANTOM STUDY. Radiat Prot Dosimetry 2021; 193:237-246. [PMID: 33893506 DOI: 10.1093/rpd/ncab052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 03/09/2021] [Accepted: 03/25/2021] [Indexed: 06/12/2023]
Abstract
The aim of this phantom study is to examine radiation doses of dual- and single-energy computed tomography (DECT and SECT) in the chest and upper abdomen for three different multi-slice CT scanners. A total of 34 CT protocols were examined with the phantom N1 LUNGMAN. Four different CT examination types of different anatomic regions were performed both in single- and dual-energy technique: chest, aorta, pulmonary arteries for suspected pulmonary embolism and liver. Radiation doses were examined for the CT dose index CTDIvol and dose-length product (DLP). Radiation doses of DECT were significantly higher than doses for SECT. In terms of CTDIvol, radiation doses were 1.1-3.2 times higher, and in terms of DLP, these were 1.1-3.8 times higher for DECT compared with SECT. The third-generation dual-source CT applied the lowest dose in 7 of 15 different examination types of different anatomic regions.
Collapse
Affiliation(s)
- Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| | - Britta König
- Faculty of Physical Engineering, Westphalian University, Campus Gelsenkirchen, Neidenburger Str. 43, Gelsenkirchen 45897, Germany
| | - Sebastian Blex
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| | - Marcel Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| | - Sandra Maier
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| | - Waldemar Zylka
- Faculty of Physical Engineering, Westphalian University, Campus Gelsenkirchen, Neidenburger Str. 43, Gelsenkirchen 45897, Germany
| | - Hilmar Kühl
- Department of Radiology, St. Bernhard-Hospital Kamp-Lintfort GmbH, Bürgermeister-Schmelzing-Str. 90, Kamp-Lintfort 47475, Germany
| | - Axel Wetter
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
- Department of Diagnostic and Interventional Radiology, Neuroradiology, Asklepios Klinikum Harburg, Eißendorfer Pferdeweg 52, Hamburg 21075, Germany
| | - Nika Guberina
- Department of Radiotherapy, West German Cancer Center, University Hospital Essen, Hufelandstrasse 55, Essen 45147, Germany
| |
Collapse
|
28
|
Zensen S, Wetter A, Tsagakis K, Schlosser T. Aneurysma einer aberranten rechten Arteria subclavia (Arteria lusoria) als seltene Komplikation einer meist asymptomatischen Gefäßanomalie. ROFO-FORTSCHR RONTG 2020; 193:713-715. [PMID: 33003247 DOI: 10.1055/a-1250-8676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany
| | - Axel Wetter
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany
| | - Konstantinos Tsagakis
- Department of Thoracic and Cardiovascular Surgery, University Hospital Essen, Germany
| | - Thomas Schlosser
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany
| |
Collapse
|
29
|
Opitz M, Bos D, Deuschl C, Radbruch A, Zensen S, Sirin S, Forsting M, Bechrakis N, Biewald E, Bornfeld N, Ketteler P, Timmermann B, Stuschke M, Guberina M, Wetter A, Göricke S, Guberina N. Estimation of radiation exposure of children undergoing superselective intra-arterial chemotherapy for retinoblastoma treatment: assessment of local diagnostic reference levels as a function of age, sex, and interventional success. Neuroradiology 2020; 63:391-398. [PMID: 32862237 PMCID: PMC7880957 DOI: 10.1007/s00234-020-02540-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 08/23/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE This study aims to determine local diagnostic reference levels (LDRLs) of intra-arterial chemotherapy (IAC) procedures of pediatric patients with retinoblastoma (RB) to provide data for establishing diagnostic reference levels (DRLs) in pediatric interventional radiology (IR). METHODS In a retrospective study design, LDRLs and achievable dose (AD) were assessed for children undergoing superselective IAC for RB treatment. All procedures were performed at the flat-panel angiography systems (I) ArtisQ biplane (Siemens Healthineers) and (II) Allura Xper (Philips Healthcare). Patients were differentiated according to age (A1: 1-3 months; A2: 4-12 months; A3: 13-72 months; A4: 73 months-10 years; A5: > 10 years), sex, conducted or not-conducted chemotherapy. RESULTS 248 neurointerventional procedures of 130 pediatric patients (median age 14.5 months, range 5-127 months) with RB (68 unilateral, 62 bilateral) could be included between January 2010 and March 2020. The following diagnostic reference values, AD, and mean values could be determined: (A2) DRL 3.9 Gy cm2, AD 2.9 Gy cm2, mean 3.5 Gy cm2; (A3) DRL 7.0 Gy cm2, AD 4.3 Gy cm2, mean 6.0 Gy cm2; (A4) DRL 14.5 Gy cm2, AD 10.7 Gy cm2, mean 10.8 Gy cm2; (A5) AD 8.8 Gy cm2, mean 8.8 Gy cm2. Kruskal-Wallis-test confirmed a significant dose difference between the examined age groups (A2-A5) (p < 0.001). There was no statistical difference considering sex (p = 0.076) and conducted or not-conducted chemotherapy (p = 0.627). A successful procedure was achieved in 207/248 cases. CONCLUSION We report on radiation exposure during superselective IAC of a pediatric cohort at the German Retinoblastoma Referral Centre. Although an IAC formally represents a therapeutic procedure, our results confirm that radiation exposure lies within the exposure of a diagnostic interventional procedure. DRLs for superselective IAC are substantially lower compared with DRLs of more complex endovascular interventions.
Collapse
Affiliation(s)
- Marcel Opitz
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany.
| | - Denise Bos
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Cornelius Deuschl
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Alexander Radbruch
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Sebastian Zensen
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Selma Sirin
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Michael Forsting
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Nikolaos Bechrakis
- Department of Ophthalmology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Eva Biewald
- Department of Ophthalmology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Norbert Bornfeld
- Department of Ophthalmology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Petra Ketteler
- Department of Pediatric Hematology and Oncology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Beate Timmermann
- Department of Particle Therapy, University Hospital Essen, West German Cancer Center, German Cancer Consortium (DKTK), Hufelandstrasse 55, 45147, Essen, Germany
| | - Martin Stuschke
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, Hufelandstrasse 55, 45147, Essen, Germany
| | - Maja Guberina
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, Hufelandstrasse 55, 45147, Essen, Germany
| | - Axel Wetter
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Sophia Göricke
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
| | - Nika Guberina
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany
- Department of Radiotherapy, University Hospital Essen, West German Cancer Center, Hufelandstrasse 55, 45147, Essen, Germany
| |
Collapse
|