1
|
[Detection of Aspergillus antigen galactomannan using ELISA method: validation of the performances of the method for accreditation]. J Mycol Med 2013; 23:33-9. [PMID: 23375860 DOI: 10.1016/j.mycmed.2012.12.048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Revised: 12/13/2012] [Accepted: 12/17/2012] [Indexed: 10/27/2022]
Abstract
Diagnosis of invasive aspergillosis for patients with high risk of infection is based on the monitoring of Aspergillus antigenemia assessed by the detection of galactomannan in serum by a sandwich-type ELISA (Biorad(®)). The validation of the method was displayed according to the guide COFRAC SH GTA 04. The internal quality control system settled, involves two quality control samples made of pools of sera (negative and positive). The repeatability of the measurements, as estimated by the coefficients of variation (CV), obtained by two different technicians was found from 9 to 13.7% for the positive control. The CV of the negative control, for which the provider indicates it is not useful in the analytical process, was found from 7.1 to 30%. In our experience it could be an indicator of environmental contamination. The evaluation of the intermediary fidelity was 15.7% for the positive control and 22.5% for the negative one. In the lack of reference material (International Standard) and recommendation from scientific societies, performances obtained will be discussed according to the results reported in the technical form of the supplier and those obtained by 39 laboratories participating in the only available external quality assessment program organized in France by ProBioQual(®) where the CV of reproducibility are 44.7% of unit (mean index 0.131) for the negative control and 18% (mean index 1.089) for the positive one in 2011.
Collapse
|
2
|
Glycolytic profile in normal brain tissue and gliomas determined by a micro-method analysis. Oncol Rep 2012; 3:165-70. [PMID: 21594337 DOI: 10.3892/or.3.1.165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
High aerobic glycolysis is frequent in cancers. Glucose phosphorylation is under control of hexokinase which is found in the cytosol or bound to mitochondria. Glycolysis parameters (glucose, pyruvate and lactate) and hexokinase were evaluated in extracts of 15 human gliomas and of normal brain tissue. Extracts were run and analysed for glucose lactate and pyruvate content using a centrifugal automatic analyzer, Mitochondria fractions were separated from total extracts and hexokinase enzymatic activities were measured in both, using an original micro-method. Conditions of hexokinase assay were standardized in terms of substrate concentration and linearity. Mean hexokinase activity in gliomas was variable, 3 times lower than in normal tissues and mainly bound to mitochondria, although lactate/pyruvate ratios were found to be 3.5 to 5.4 times higher. Glycolytic profile of tumor tissues can be rapidly assayed and evalated glycolysis in tumors could constitute a basis for therapy using antiglycolytic strategies.
Collapse
|
3
|
[Medium-chain acyl-CoA-dehydrogenase (MCAD) deficiency: French consensus for neonatal screening, diagnosis, and management]. Arch Pediatr 2012; 19:184-93. [PMID: 22244319 DOI: 10.1016/j.arcped.2011.10.025] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2011] [Accepted: 10/28/2011] [Indexed: 12/30/2022]
Abstract
MCAD deficiency is the most common fatty acid oxidation disorder, with the prevalence varying from 1/10,000 to 1/27,000 in the countries adjacent to France. As the High Authority for Health has recently proposed including MCAD deficiency in the panel of diseases neonatally screened for in France, a consensus was written for the management of MCAD deficiency diagnosed either clinically or by neonatal screening. Patients may present acutely with hyperammonemia, hypoglycemia, encephalopathy, and hepatomegaly, mainly after a prolonged fast of intercurrent infection. Sudden death related to heartbeat disorders may also occur. The diagnosis of MCAD deficiency is suspected on the plasma acylcarnitine and/or the urinary organic acid profile. The diagnosis is confirmed by molecular biology and the enzymatic activity for patients who are not homozygous for the main mutation c.985A>G. However, some MCAD-deficient individuals may remain asymptomatic throughout life. The mainstay of treatment consists in avoiding prolonged fast and prescribing l-carnitine for patients who exhibit a deficiency in plasma carnitine. This management has radically modified the natural history of MCAD deficiency. This consensus will allow homogeneous management of these patients once the neonatal screening of MCAD deficiency has been introduced in France.
Collapse
|
4
|
[Interlaboratory comparison/external quality assessment]. Ann Biol Clin (Paris) 2010; 68 Spec No 1:227-236. [PMID: 23826616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
External quality assessment is an important issue in the demonstration of the quality of analytical process. The aim of this document is to help the laboratory in the choice, implementation and interpretation of external quality assessment schemes.
Collapse
|
5
|
[Recommendations for expressing uncertainty of measurement of quantitative results in laboratory medicine]. Ann Biol Clin (Paris) 2007; 65:185-200. [PMID: 17353174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
In laboratory medicine, the quantitative results of examinations are interpreted with regard to reference intervals, clinical decision limits or previous results of a patient, from which it is necessary to inform the clinician about the uncertainty of measurement linked to the value of the result. This document explains the problematic of the expression of the uncertainty of measurement. It proposes recommendations concerning a simple way to evaluate uncertainty of measurement using long term internal quality control data and the value of the uncertainty linked to the method calibration. It approaches the determination of analytical goals and the choice of methods and also the comments accompanying the record of results and a help to their interpretation.
Collapse
|
6
|
[Advances in clinical biology. Biological markers for assessment of liver fibrosis in chronic liver diseases]. Ann Biol Clin (Paris) 2006; 64:603-7. [PMID: 17256242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
|
7
|
[Recommendations for the installation in the laboratory of metrological functions and corresponding documentation (Document B)]. Ann Biol Clin (Paris) 2004; 62:479-86. [PMID: 15297246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
In order to ensure the quality of analytical results, clinical laboratories shall have a perfect control of process and equipments of measurement. Therefore is recommended individualisation of metrological function, generally entrusted the quality manager. This quality manager will draw up a metrological traceability, verifications and confirmations, control of non conformities, follow-up and evaluation of metrological function.
Collapse
|
8
|
[Presentation for the use of a clinical laboratories of standards of metrology (Document A)]. Ann Biol Clin (Paris) 2004; 62:121-5. [PMID: 15047503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/29/2023]
Abstract
Clinical laboratories shall have a perfect control of "in vitro diagnostic medical devices" to ensure the quality of their analytical results. This introductory presentation to a serie of documents of recommendations tackles the different standards of metrology concerning the requirements to reference materials, metrological traceability, metrological confirmation, management of measurement as well as uncertainty of measurement. The standards concerning clinical laboratories are then succinctly described.
Collapse
|
9
|
[Internal quality audit questionnaire in the LABM of health facilities]. Ann Biol Clin (Paris) 2002; 60:111-22. [PMID: 11830403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
|
10
|
[Control of the quality of drug doses in the framework of therapeutic surveillance: Asqualab program 1997-1999]. Ann Biol Clin (Paris) 2000; 58:630-6. [PMID: 11022111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
|
11
|
|
12
|
[Quality specifications and allowable standards for validation of methods used in clinical biochemistry]. Ann Biol Clin (Paris) 1999; 57:685-95. [PMID: 10572217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
The purpose of this work is to provide, for a large number of analysis in the field of clinical biochemistry, appropriate criteria for the evaluation of the performance of in vitro diagnostic methods. Based on a first set of data established in 1986 and the experience cumulated by organisers in charge of internal and external quality assessment surveys, an expert group has proposed acceptable limits for a large list of analysis (n = 116). Data are reported and presented in tables divided into 7 chapters including: general biochemistry, enzymes, proteins, tumour markers, hormones, drugs (and toxic), and urinary analysis. For each analysis are given: analytical and reference ranges, three concentration levels for control specimens to be used during evaluations and the range of values within which they can be chosen, reproducibility and repeatability limits expressed as CV%. Maximal tolerable systematic error and inaccuracy are given for control and biological specimens and compared to those obtained using a reference or validated method. These data are essential for evaluations using the protocol designed by the SFBC and can serve as quality criteria for the choice and validation of in vitro diagnostic systems.
Collapse
|
13
|
[Biological examination in the diagnosis and monitoring of liver disease. Algorithms to aid the decision]. PATHOLOGIE-BIOLOGIE 1999; 47:1016-32. [PMID: 10609282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
The goal of this article is to describe a rational step-wise strategy for using standard laboratory tests to obtain diagnostic orientation for a liver disorder; establish, support, or rule out a liver disorder; and monitor the course of treated and untreated patients with liver disorders.
Collapse
|
14
|
[Alcohol and liver]. PATHOLOGIE-BIOLOGIE 1999; 47:945-57. [PMID: 10609275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
The first part of this article is devoted to the metabolism of alcohol and the mechanisms underlying its hepatotoxicity. The second part describes the clinical features of the various patterns of alcohol-related liver disease (ARLD). The third part focuses on the characteristics, semiological value, and limitations of serum markers used in ARLD. Tests used to screen for alcohol abuse (blood alcohol, MCV, GGT, CDT, and FAEE) differ from those used to monitor alcohol withdrawal and to detect early-stage liver disease (ALT, AST, ASTm, alphaGST, and redox status).
Collapse
|
15
|
A new approach for clinical biological assay comparison and standardization: application of principal component analysis to a multicenter study of twenty-one carcinoembryonic antigen immunoassay kits. Clin Chem 1999; 45:869-81. [PMID: 10351997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
BACKGROUND Principal component analysis (PCA) is a powerful mathematical method able to analyze data sets containing a large number of variables. To our knowledge, this method is applied here for the first time in the field of medical laboratory analysis. METHODS PCA was used to evaluate the results of a blind comparative study of 21 carcinoembryonic antigen (CEA) reagent kits used to determine CEA concentration in a panel of sera from 80 patients. RESULTS The mathematical technique first eliminated the variations attributable to the use of different calibrators. The PCA representation then gave a global view of the dispersion of the kits and allowed the identification of a main homogeneous group and of some discrepant kits. CONCLUSIONS PCA applied to the in vitro diagnostic reagent field could contribute to the standardization process and improve the quality of medical laboratory analyses. A standardization method using a panel of patient sera is proposed.
Collapse
|
16
|
[Program of external quality control in cyclosporine dosage: summary and analysis from French laboratories]. Ann Biol Clin (Paris) 1999; 57:360-3. [PMID: 10377491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
17
|
Interassay calibration as a major contribution to the comparability of results in clinical enzymology. Clin Biochem 1998; 31:489-94. [PMID: 9740971 DOI: 10.1016/s0009-9120(98)00038-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Factors contributing to the applicability of interassay calibration of methods measuring enzyme catalytic activities are described. Also discussed are the properties essential for such a material. Similarity of specificity for the methods to be calibrated as well as commutability between the material(s) intended to be used as calibrator are the main criteria to be satisfied. RESULT Several examples demonstrated that interassay calibration is feasible but a multi-enzyme calibrator with a wide commutability for the most popular methods remains to be developed. This is the project of the IFCC Working Group on Calibrators in Clinical Enzymology (WG-CCE). Several experimental data are also presented that indicate that the temperature at which the reaction is carried out is not a limiting factor in the implementation of interassay calibration in clinical enzymology.
Collapse
|
18
|
Validation of an enzyme calibrator--an IFCC guideline. International Federation of Clinical Chemistry. Clin Biochem 1998; 31:495-500. [PMID: 9740972 DOI: 10.1016/s0009-9120(98)00039-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The objective of this guideline is to improve standardization in clinical enzymology in order to improve intermethod comparability of patients' results. DESIGN AND METHODS The reference system, combination of the reference method and the reference material, is used to produce a reference value for a given catalytic activity. Sets of methods are formed of methods exhibiting the same analytical specificity. Materials intended to be used as enzyme calibrators are experimentally checked for their commutability. RESULTS The transfer of accuracy from the reference value to patients' results is dependent on methods (analytical specificity) and on materials (experimentally assessed commutability). The feasibility of this approach was demonstrated with materials of high level for several enzymes and for each of them for several routine methods. CONCLUSION Expected advantages of this approach in clinical enzymology are presented.
Collapse
|
19
|
[Daily practice in clinical enzymology: the danger of utilizing conversion factors tied to measured temperature]. Ann Biol Clin (Paris) 1998; 56:359-61. [PMID: 9754271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
20
|
Abstract
OBJECTIVE To evaluate the state of the art concerning GHb assays through analysis of a large-scale quality control survey and to compare the results with those of previous surveys. RESEARCH DESIGN AND METHODS A lyophilized hemolyzate prepared from human erythrocytes containing a physiological HbA1c level (5.5%) was sent to 3,500 French laboratories in February of 1995 and assayed as a patient's sample under routine conditions. Distribution of values was analyzed from the reported results for each method. The results were compared with the assigned value (acceptable range: +/- 20%) and with the upper value of the reference range currently used. RESULTS Results were obtained from 2,674 laboratories, among which 39% used cation-exchange chromatography methods, 37.5% affinity chromatography, 16% immunological methods, and 7.5% electrophoresis. The number of laboratories using immunological methods increased from 100 to 400 between 1993 and 1995. The overall interlaboratory coefficient of variation (CV) was 20.2%, with within-method CVs ranging between 3.2 and 29.5%. Method-to-method accuracy varied dramatically, with mean HbA1c values ranging from 4.4 to 8.2%. Results from 75% of the laboratories were comprised in the acceptable range; 88% of them reported a value within the normal range of the method used. CONCLUSIONS The interlaboratory variability of results illustrates the difficulties encountered by diabetologists in the follow-up of diabetic patients using results obtained from different laboratories. It demonstrates the usefulness of the internationally developed standardization process of GHb measurements and points out the need for laboratories to fulfill good practices.
Collapse
|
21
|
Abstract
OBJECTIVE To evaluate the efficiency and tolerance of venovenous hemofiltration, hemodiafiltration, and hemodialysis with a two-pump system in a neonatal animal model of acute renal failure. DESIGN Prospective trial. SETTING Animal laboratory at a large university-affiliated medical center. SUBJECTS New Zealand white rabbits, weighing 3325 +/- 380 g. INTERVENTIONS Venovenous hemofiltration, hemodiafiltration, and hemodialysis were performed in anesthetized rabbits with previous bilateral ureteral ligation. MEASUREMENTS AND MAIN RESULTS At a blood flow rate of 19 +/- 0.5 mL/min, we determined hematocrit, urea, creatinine, and electrolyte values in blood, at the inlet and outlet of the hemofilter, and in ultrafiltrate at the start and after 15, 30, 60, 90, 120, and 180 mins of hemofiltration (ultrafiltrate flow rate of 1.9 +/- 0.2 mL/min), hemodiafiltration (dialysate plus ultrafiltrate flow rate of 16.9 +/- 0.8 mL/min), and hemodialysis (dialysate flow rate of 15.7 +/- 1.1 mL/min). Arterial blood pressure, heart rate, and body temperature were monitored during the procedures. Urea and creatinine instantaneous clearances were higher with hemodiafiltration (8.0 +/- 0.7 and 6.2 +/- 0.7, respectively, n = 29) and hemodialysis (6.8 +/- 1.1 and 4.8 +/- 0.9, respectively, n = 31) than with hemofiltration (1.8 +/- 0.6 and 1.9 +/- 0.4, respectively, n = 16). Initial and final weights, temperatures, and hematocrit, sodium, and protein blood concentrations of each 180-min procedure were similar. CONCLUSIONS Hemodiafiltration had a higher urea removal rate than hemodialysis but the management of hemodiafiltration was more cumbersome and time consuming in the absence of a flow equalizer device. As a result, we recommend continuous venovenous hemodialysis as the therapy of choice.
Collapse
|
22
|
Tolerance to starvation in children on long-term total parenteral nutrition. Clin Nutr 1997; 16:113-7. [PMID: 16844582 DOI: 10.1016/s0261-5614(97)80236-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/10/1997] [Indexed: 10/26/2022]
Abstract
To evaluate the consequences of long-term cyclic total parenteral nutrition (TPN) on metabolic pathways which contribute to energy metabolism, adaptation to starvation was studied in a group of seven children 2-7 years old, on long-term cyclic TPN. In addition to clinical monitoring, the following biological parameters were measured: blood levels of glucose, free fatty acids, ketone bodies and carnitine, and urinary excretion of dicarboxylic acids. Five of the seven children had good clinical tolerance up to 30 h of fasting. This indicated that metabolic changes arising from prolonged cyclic TPN are easily reversed when such children are fasting. The other two children had to be refed after 22 and 24 h, respectively. Both had metabolic signs of impaired hepatic fatty acid oxidation or ketogenesis. These metabolic changes might reflect the liver failure caused by TPN in these children, and stresses the fact that prolonged starvation has to be carefully monitored in patients with liver dysfunction secondary to TPN.
Collapse
|
23
|
[Improvements from the reference material CRM 470 in the standardization of the determination of serum proteins]. Ann Biol Clin (Paris) 1997; 55:37-40. [PMID: 9099250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The introduction of the CRM 470 in 1993 (certified reference material for 14 serum proteins) and its utilization by industrial companies for cross-calibrating their commercial standards has been an important break-through in protein standardization. This improvement has been clearly illustrated by the last national quality control survey performed in France in may 1995. At this time, about 60% of the 1,870 participants have already adopted the new standardization. The between-run precision (interlaboratory and intertechnique) has been considerably improved by the use of the new international standard (5.8 to 12.2% versus 10 to 24.1% before standardization); the same is true for accuracy. These results should convince the last reluctant laboratories to adopt the new standardization. Thus, it seems now possible to define reference ranges for serum proteins: this is the new task assigned to the Committee for Plasma Protein Standardization of the IFCC.
Collapse
|
24
|
Validation protocol of analytical hemostasis systems: measurement of anti-Xa activity of low-molecular-weight heparins. Clin Chem 1996. [DOI: 10.1093/clinchem/42.8.1223] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
A standard validation protocol adapted to the chromogenic assay of anti-Xa activity of low-molecular-weight heparins was used in a multicenter study to assess its suitability for comparing and evaluating analytical hemostasis systems. The protocol included: familiarization with the system (repeatability); assessment of limits of linearity, detection limits, and cross-contamination; and validation (reproducibility and accuracy of measurements of treated patients' plasmas). We calibrated the systems with the same range of lyophilized plasmas daily and evaluated repeatability and reproducibility by using a single batch of lyophilized plasmas at three anti-Xa activities. The two automated systems tested [SB 300 (Gilford) and ACL (IL)] and the two semiautomated systems [ST 888 (D. Stago) and Chromotimer (Behring)] gave similar mean values. Dispersion of results was lower with the automated systems than with the semiautomated ones, especially at low anti-Xa activities, a tendency that also was observed for reproducibility. Because each analytical system gave linear results for activities as great as 1000 IU/L, suitable sample dilution is advisable for higher anti-Xa activities. Accuracy was greater in the automated systems. We conclude that this protocol is feasible and is applicable to validation of other analytical hemostasis instruments, in particular the latest generation of fully automated instruments.
Collapse
|
25
|
Validation protocol of analytical hemostasis systems: measurement of anti-Xa activity of low-molecular-weight heparins. Clin Chem 1996; 42:1223-30. [PMID: 8697581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
A standard validation protocol adapted to the chromogenic assay of anti-Xa activity of low-molecular-weight heparins was used in a multicenter study to assess its suitability for comparing and evaluating analytical hemostasis systems. The protocol included: familiarization with the system (repeatability); assessment of limits of linearity, detection limits, and cross-contamination; and validation (reproducibility and accuracy of measurements of treated patients' plasmas). We calibrated the systems with the same range of lyophilized plasmas daily and evaluated repeatability and reproducibility by using a single batch of lyophilized plasmas at three anti-Xa activities. The two automated systems tested [SB 300 (Gilford) and ACL (IL)] and the two semiautomated systems [ST 888 (D. Stago) and Chromotimer (Behring)] gave similar mean values. Dispersion of results was lower with the automated systems than with the semiautomated ones, especially at low anti-Xa activities, a tendency that also was observed for reproducibility. Because each analytical system gave linear results for activities as great as 1000 IU/L, suitable sample dilution is advisable for higher anti-Xa activities. Accuracy was greater in the automated systems. We conclude that this protocol is feasible and is applicable to validation of other analytical hemostasis instruments, in particular the latest generation of fully automated instruments.
Collapse
|
26
|
Production and certification of an enzyme reference material for pancreatic alpha-amylase (CRM 476). Clin Chim Acta 1996; 251:145-62. [PMID: 8862470 DOI: 10.1016/0009-8981(96)06302-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We describe the preparation of a lyophilized material containing purified human pancreatic alpha-amylase and the certification of its catalytic concentration. The enzyme was purified from human pancreas by ammonium sulphate precipitation and chromatography successively on DEAE-Sephacel, CM-Sepharose and Sephadex G-75. The purified enzyme had a specific activity of 52.9 kU/g protein and was > 99% pure on polyacrylamide gel electrophoresis. Only trace amounts of lipase and lactate dehydrogenase were detected in the purified fraction. The purified pancreatic alpha-amylase had a molar mass of 57,500 g/mol and an isoelectric point at 7.1. The material was prepared by diluting the purified alpha-amylase in a matrix containing PIPES buffer 25 mmol/l, pH 7.0, sodium chloride 50 mmol/l, calcium chloride 1.5 mmol/l, EDTA 0.5 mmol/l and human serum albumin 30 g/l, dispensing in ampoules and freeze-drying. The ampoules were homogeneous and the yearly loss of activity on the basis of accelerated degradation studies was less than 0.01% at -20 degrees C. The certified value for alpha-amylase catalytic concentration in the reconstituted reference material is 555 U/l +/- 11 U/l when measured by the specified method at 37 degrees C. The material can be used to verify the comparability of results from laboratories, for intra-laboratory quality control or for calibration of alpha-amylase catalytic concentration measurements.
Collapse
|
27
|
Abstract
A number of acquired conditions including infections, severe catabolic states, tissue anoxia, severe dehydration and poisoning can give rise to hyperlactacidaemia. All these causes should be ruled out before considering inborn errors of metabolism. Carefully collected samples are necessary if artefacts that result in spuriously increased lactate/pyruvate (L/P) and 3-hydroxybutyrate/acetoacetate (B/A) ratios are to be avoided. When properly performed, 24-h studies of L/P and B/A ratios provide a useful tool in making a diagnosis. A few metabolic profiles when present are specific or highly suggestive of a given disorder. When the L/P ratio is normal or low, pyruvate dehydrogenase (PDH) deficiency is highly probable whatever the lactate concentration, which is often only moderately elevated after meal, may be. When the L/P ratio is very high in association with post-prandial hyperketonaemia and in contrast to a normal or low B/A ratio, pyruvate carboxylase (PC) deficiency and alpha-ketoglutarate dehydrogenase (KGDH) deficiency are the most likely diagnoses. The distinction between the two disorders relies upon amino acid and organic acid profiles (glutamate and alpha-ketoglutarate accumulations in KGDH deficiency and hyperammonaemia and hypercitrullinaemia in PC deficiency). When both L/P and B/A ratios are elevated and associated with significant post-prandial hyperketonaemia, respiratory-chain disorders should first be suspected. All other profiles, especially a high L/P ratio without hyperketonaemia, are compatible with respiratory-chain disorders but are not specific; all acquired anoxic conditions should also be ruled out. Clearly, the clinical utility of these profiles needs to be interpreted cautiously in very ill patients in relation to the cardiocirculatory condition and to therapy. Finally, a normal profile, even after stress and loading, does not rule out an inborn error of lactate/pyruvate oxidation.
Collapse
|
28
|
[Method selected for the determination of creatinine in plasma or serum. Choice of optimal conditions of measurement]. Ann Biol Clin (Paris) 1996; 54:285-98. [PMID: 9092308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The method selected by the SFBC (Société française de biologie clinique) is derived from the colorimetric reaction of creatinine with alkaline picrate, measured kinetically, without any pretreatment step. The key parameters of the reaction determining the quality of the results are studied, with special regard to samples including known interferents. The aims of the study were to gain an optimal analytical sensitivity and to reduce main interferences (acetoacetate, bilirubine, glucose, protein) which plague the Jaffé reaction, through a comprehensive study of the reagents, of their concentrations and of the analytical procedures. The selected concentrations (in the test) are: 150 mmol/L sodium hydroxide, 10 mmol/L picric acid and 2 g/L sodium dodecyl sulfate. Ten millilitres of a BRIJ solution (30% volvol) are added to the reagent. The operating procedures are as follow: sample ratio 0.07 to 0.08; wavelength 505 to 510 nm; temperature 37 degrees C; incubation of the specimen with the alkaline reagent 5 mn (at least), before starting the reaction with picric acid. A seric calibrator is recommended. The first measurement is taken 20 to 40 s after starting the reaction. Total measurement time is 120 to 150 seconds.
Collapse
|
29
|
[Validation and study of the transferability of the selected technique by SFBC for the determination of creatinine in plasma]. Ann Biol Clin (Paris) 1996; 54:299-308. [PMID: 9092309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A selected method for the determination of creatinine in plasma, using the reaction with alkaline picrate without prior pretreatment has been proposed by the Commission 'Validation de techniques' in the SFBC (Société Française de biologie clinique). The transferability step was conducted in seven laboratories, equipped with different automatic analyzers, using analytical procedures derived from the recommended method. Its goal was to test whether the original analytical performances could be maintained and consistent results obtained. The validation step was designed to evaluate the linearity limits of the analytical range, the detection limit, to assess accuracy as compared to a high performance liquid chromatography and to investigate the effect of the main interferents. Linearity limits are 15 and 2000 mumol/L. The detection limit is 3 to 8 mumol/L according to the analytical systems. The selected method can fulfil the set imprecision goals: intralaboratory CV minus than 2% (within-run), minus than 4% (run-to-run), interlaboratory CV minus than 5% (for 100 mumol/L creatinine). Inaccuracy evaluated for the chosen control sera is 1 to 15% as compared to the chromatographic method, according to the sera and to the analytical systems. The results obtained with the selected method are more consistent with the HPLC than are those obtained with an alkaline picrate method without SDS or with an enzymatic method. No interference could be demonstrated for acetoacetate (up to 8 mmol/L), hemoglobin (up to 210 mumol/L), unconjugated bilirubin (up to 250 mumol/L), glucose (up to 30 mmol/L), IgG (up to 45 g/L), albumin (up to 60 g/L). The effect of cephalosporins depends on the molecule. The reagents are stable for at least 6 months when stored in closed vials at +20 degrees C. The alkaline reagent is stable 30 days at +4 degrees C. Reference limits (0.025 and 0.975 fractiles) have been established for healthy adults. They are respectively 73 to 126 mumol/L for men and 59 to 100 mumol/L for females.
Collapse
|
30
|
Abstract
Abstract
We report the results of a national quality-control survey on glycohemoglobin (GHb), monitored in France by the Société Française de Biologie Clinique on behalf of the authority of the "Agence du Médicament." A sample of lyophilized hemolysate was sent to 3109 laboratories. Results were obtained from 2770 laboratories. HbA1C, HbA1, and total GHb were measured by 50%, 24%, and 26% of the participants, respectively. Of these measurements, 79% of the HbA1C results and 76% of the total GHb results, but only 48% of the HbA1 results, were within the +/- 20% limits of the indicated target values. Mean values for the hemolysate ranged from 8% to 11% for HbA1C, from 7% to 12% for HbA1, and from 11% to 13% for total GHb. The interlaboratory CVs ranged from 3% to 20%, according to method used. So, methods used for GHb assay, which are based on various principles, exhibit very different analytical performances. Nonetheless, this large-scale study indicates that some techniques can support transferability of results from laboratory to laboratory.
Collapse
|
31
|
Glycohemoglobin assays evaluated in a large-scale quality-control survey. Clin Chem 1995; 41:1644-8. [PMID: 7586556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We report the results of a national quality-control survey on glycohemoglobin (GHb), monitored in France by the Société Française de Biologie Clinique on behalf of the authority of the "Agence du Médicament." A sample of lyophilized hemolysate was sent to 3109 laboratories. Results were obtained from 2770 laboratories. HbA1C, HbA1, and total GHb were measured by 50%, 24%, and 26% of the participants, respectively. Of these measurements, 79% of the HbA1C results and 76% of the total GHb results, but only 48% of the HbA1 results, were within the +/- 20% limits of the indicated target values. Mean values for the hemolysate ranged from 8% to 11% for HbA1C, from 7% to 12% for HbA1, and from 11% to 13% for total GHb. The interlaboratory CVs ranged from 3% to 20%, according to method used. So, methods used for GHb assay, which are based on various principles, exhibit very different analytical performances. Nonetheless, this large-scale study indicates that some techniques can support transferability of results from laboratory to laboratory.
Collapse
|
32
|
Usefulness of reference materials in calibration of enzyme activities. EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY : JOURNAL OF THE FORUM OF EUROPEAN CLINICAL CHEMISTRY SOCIETIES 1995; 33:859-64. [PMID: 8620064 DOI: 10.1515/cclm.1995.33.11.859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
alpha-Amylase, alkaline phosphatase and gamma-glutamyltransferase were studied in a multicentre evaluation. Analyses were performed on different patient samples. Each enzyme was assayed in two different laboratories at both 30 and 37 degrees C, with widely used reagent kits and with the IFCC reference method (if in existence). Results differed considerably according to the measurement procedure. Data also showed that it was not possible to employ a constant conversion factor for one enzyme and different techniques between 30 and 37 degrees C. Calibration with three reference materials extensively improved the intermethod consistency for most of the tested measurement procedures. It was possible to transfer accuracy from the method used for the certification of the reference material to routine procedures, by using the reference material as calibrator. Temperature did not seem to be a crucial variable for the implement of the enzyme calibrator approach.
Collapse
|
33
|
Abstract
Hexokinase plays an important role in glucose-utilizing tissues like normal brain and cancers. In these tissues, hexokinase (HK) is mainly bound to mitochondria (mHK). Our objectives were to evaluate total HK (tHK) activity and mHK fraction in gliomas and to determine whether mHK binding could be targeted for therapy. Tumors were obtained from 26 patients and 13 were xenografted. HK, lactate and ATP were measured in cytosol and mitochondria extracts. The tHK expressed in mU/mg protein were 147 +/- 19 and 78 +/- 12, in fresh gliomas and xenografts, respectively, and of 489 in the normal brain. The mHK fraction was 76% in normal brain, 74 +/- 4% in fresh tumors and 53 +/- 6% in xenografts. Lactate/mHK ratios were higher in gliomas than in normal brain. The ATP was 10, 52 +/- 31 and 19 +/- 8 nmol/mg protein in normal brain, xenografts and fresh gliomas respectively. Loss of one copy of chromosome 10 which carries the HK1 gene, was evidenced in 11 of the 13 xenografted gliomas. The anti-tumor effect of lonidamine (LND), which affects glycolysis in interfering with mHK activity, was tested in nude mice bearing 4 gliomas. LND (125 mg/kg, given i.p., twice daily for 5 days) led to a growth inhibition of TG-7-RO of 72%, with 2-fold growth retardation, and had no effect for TG-8-OZ. Intermediate LND-sensitivities for TG-11-DU and TG-10-PY were noted. The LND-sensitivity was correlated with the mHK activity (R2 = 0.73) and mHK fraction (R2 = 0.88). HK binding to mitochondria is a key of glycolysis in malignant gliomas, and targetting this binding with appropriate agents could be an effective therapeutic approach.
Collapse
|
34
|
Transplantation intrasplénique d'hépatocytes daas le déficit en ornithine transcarbamylase. Arch Pediatr 1995. [DOI: 10.1016/0929-693x(95)90194-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
35
|
Abstract
Early recognition of infantile asthma in wheezing infants is a major problem for physicians. We investigated whether detection of early sensitization to inhalant allergens would be useful to identify those wheezing infants who are likely to develop asthma. A total of 67 infants (aged 1-25 months) hospitalized for a wheezing episode were initially tested for reactivity to inhalant allergens by both skin prick test and in vitro measurement of specific IgE antibodies (Phadiatop). Thirty-seven of the infants were already considered to have infantile asthma, and 30 presented only their first or second wheezing episode when included in the study. All infants were followed for a mean period of 18 months. Seventeen (25%) infants, including seven infants initially not asthmatic, had positive prick test to Dermatophagoides pteronyssinus or to cat fur. All of these children were diagnosed as suffering from infantile asthma at the end of the follow-up. Thus, skin test positivity to inhalant allergens was significantly associated with the diagnosis of infantile asthma (P < 0.05) and could be considered to be predictive of the development of infantile asthma (P < 0.03). In contrast, Phadiatop was less sensitive than skin prick tests, and only five children had positive in vitro test results, suggesting that specific IgE may primarily bind to tissue mast cells before being detectable in serum. We concluded that sensitization to inhalant allergens may distinguish wheezing infants who develop asthma from those who do not, and that skin testing may assist the early diagnosis of asthma in wheezing infants.
Collapse
|
36
|
[Protocol of metabolic investigations in hereditary metabolic diseases]. Arch Pediatr 1994; 1:667-73. [PMID: 7987467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The authors describe a laboratory investigations protocol to be used by pediatricians facing conditions suggestive of inherited metabolic disorders. This protocol includes: 1) an emergency screening to be systematically performed during the acute clinical phase; 2) samplings to be kept frozen for possible secondary specific investigations according to the results of the emergency screening. In addition a perimortem protocol is also presented, to be applied in every lethal situations in which an inherited metabolic disorder is suspected. The equipment required in order for the clinician to properly perform the different investigations is also described.
Collapse
|
37
|
Abstract
A high-sucrose (S) diet accentuates anorexia and stunts growth in uremic (U) rats, and an oral S load induces a greater hyperfructosemia in U rats than in control (C) rats. Four studies were performed to determine the roles of S feeding and an acute S load on liver carbohydrate (CHO) metabolism in U and C rats (eight to 10 rats per group). We also examined the plasma responses to either water or a S load. Levels of the main metabolites of glycolysis, gluconeogenesis, and glycogenesis were measured under basal conditions (7 hours' postmeal) in U and C rats fed either a cornstarch diet (study I) or S diet (study II) and at 30 and 60 minutes after an intragastric S load (studies III and IV) in s-fed U and C rats. The weight gain, food intake, and plasma creatinine and urea levels of the rats in the four studies were comparable. Weight gain and liver weight (g/100 g body weight) were lower in U than in C rats. In the plasma, baseline levels of lactate were decreased by uremia and S feeding and those of glucose (G) were increased by S feeding. The increases in plasma G and fructose (F) levels after a S load were greater in U rats than in C rats, whereas those of plasma lactate were comparable. In the liver under basal conditions, uremia markedly decreased levels of glycogen, F-1,6-diphosphate (F-1,6-diP), F-2,6-diP, 3-glycero-phosphate (3-glycero-P), dihydroxyacetone phosphate (DHAP), pyruvate, lactate, and adenosine triphosphate (ATP), and the phosphorylation state (ATP/adenosine diphosphate [ADP] x inorganic phosphorus [PI]), increased phosphoenolpyruvate (PEP), ADP, and Pi levels, but did not affect the cytosolic redox state (pyruvate/lactate). In addition to uremia, S feeding further decreased levels of glycogen, F-2,6-diP, 3-glycero-P, and ATP. After S loading, liver F levels increased more in U than in C rats, but glycogen and 3-glycero-P levels increased less in U than in C rats. Liver lactate and pyruvate levels increased more in U than in C rats, and the pyruvate/lactate and DHAP/3-glycero-P ratios were higher in U than in C rats after a S load. The ATP level and the phosphorylation state in U rats increased 30 minutes later in U than in C rats. Our findings indicate that uremia causes a depletion in liver glycogen, which is enhanced by S feeding and could be partially attributed to decreased glycogen synthesis.(ABSTRACT TRUNCATED AT 400 WORDS)
Collapse
|
38
|
Serum creatinine concentration in chronic hemodialysis patients: higher predialytic levels in black males. Clin Nephrol 1993; 40:118-9. [PMID: 8222368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
|
39
|
Between-country comparability of clinical chemistry results: an international quality assessment survey of 17 analytes in six European countries through existing national schemes. Ann Clin Biochem 1993; 30 ( Pt 3):304-14. [PMID: 8517614 DOI: 10.1177/000456329303000313] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Two lyophilized control sera were distributed through seven national external quality assessment schemes in six European countries--Belgium, Switzerland, France, The Netherlands, Sweden and the United Kingdom--participated in the study. The results for 17 routine analytes were obtained from almost 5000 laboratories for the two sera. The organizers of the schemes were asked to process the results according to a common outlier removal procedure, and submit method-related data if available. The two sera were also distributed through the external/internal scheme of The Netherlands, and the within-laboratory standard deviations calculated in this scheme have been used in a scaling procedure for the external mean values and between-laboratory standard deviations of the participating countries. The results show remarkable agreement in the national mean values for practically all analytes, but considerable differences in the between-laboratory variation. Data from comparable method groups was obtained for 12 analytes from Belgium, France, The Netherlands and the UK. Though revealing some specific differences between methods and countries, the method-related data are generally in agreement with the all-method data. In this study reference method values were only available for cholesterol. The high degree of agreement found suggests, however, that mutual recognition of all-method mean values in national schemes could be acceptable, especially for analytes for which reliable reference methods are not available. The major element of variation is between-laboratory rather than between-country.
Collapse
|
40
|
Abstract
We report an inborn error of the tricarboxylic acid cycle, alpha-ketoglutarate dehydrogenase deficiency, in three siblings with hypotonia, metabolic acidosis, and hyperlactatemia immediately after birth. Neurologic deterioration resulted in death at about 30 months of age. We propose low molar ratios of ketone bodies in plasma of neonates with congenital lactic acidosis as an indication of dysfunction of the tricarboxylic acid cycle.
Collapse
|
41
|
|
42
|
Direct methods vs blanking methods for iron-determination: effect of serum turbidity. Clin Chem 1992; 38:782-3. [PMID: 1582036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
43
|
Abstract
Mitochondrial disorders have long been regarded as neuromuscular diseases only. In fact, owing to the ubiquitous nature of the oxidative phosphorylation, a broad spectrum of clinical features should be expected in mitochondrial disorders. Here, we present eight puzzling observations which give support to the view that a disorder of oxidative phosphorylation can give rise to any symptom in any organ or tissue with any apparent mode of inheritance. Consequently, we suggest giving consideration to the diagnosis of a mitochondrial disorder when dealing with an unexplained association of symptoms, with an early onset and a rapidly progressive course involving seemingly unrelated organs. Determination of lactate/pyruvate and ketone body molar ratios in plasma can help to select patients at risk for this condition.
Collapse
|
44
|
|
45
|
Hepatic activity and mRNA expression of aspartate aminotransferase isoenzymes in alcoholic and nonalcoholic liver disease. Hepatology 1991. [PMID: 1916663 DOI: 10.1002/hep.1840140408] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
|
46
|
Hepatic activity and mRNA expression of aspartate aminotransferase isoenzymes in alcoholic and nonalcoholic liver disease. Hepatology 1991; 14:620-5. [PMID: 1916663 DOI: 10.1016/0270-9139(91)90048-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
In liver and serum, AST activity is dependent on two isoenzymes, which are mitochondrial and cytosolic in nature. In an attempt to explain the well-known increase of serum mitochondrial AST-to-total AST ratio in chronic alcoholism (which is due to a specific increase of the mitochondrial isoenzyme), we analyzed: (a) liver and serum AST, ALT and glutamate dehydrogenase activities in 23 active drinkers with minimal liver changes, 11 alcoholic patients with cirrhosis who had stopped drinking, 18 nonalcoholic patients with viral chronic hepatitis and 11 subjects with normal livers; and (b) the expression of messenger RNAs for AST isoenzymes in the corresponding liver samples. Enzymatic activities were decreased in the liver irrespective of the origin of the liver disease. In patients with viral chronic hepatitis (or in those with alcoholic cirrhosis when abstinent), variations in liver proteins and messenger RNAs paralleled significant decreases in mitochondrial AST, ALT and glutamate dehydrogenase and a nonsignificant decrease of cytosolic AST. In alcoholic patients with minimal liver changes, the significant decrease of hepatic cytosolic AST, ALT and glutamate dehydrogenase activities contrasted with a close-to-normal liver mitochondrial AST activity; the increased amounts of mitochondrial AST messenger RNA give evidence for a pretranslational mechanism of regulation, indicating a possible increase in the total production of mitochondrial AST in the liver. The decrease of hepatic cytosolic AST activity was statistically significant only in alcoholic patients without cirrhosis who had a normal cytosolic AST mRNA level, thus suggesting a contributory role of translational or posttranslational regulation. In conclusion, regulation of AST isozymes during liver disease is complex, including differential, pretranslational and translational or posttranslational mechanisms.
Collapse
|
47
|
[Prostatic specific antigen (PSA). Interpretation of results as a function of the assay method]. Prog Urol 1991; 1:413-8. [PMID: 1726942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The authors compare the two PSA assay methods most widely used in France. The first method (RIA Baxter) uses an isotope marker (Iodine 125), the other (EIA Biotrol) uses an enzymatic marker (alkaline phosphatase). PSA was assayed by means of these two techniques in 2 groups of patients: one group of 49 men considered to be free of any prostatic disease, recruited from blood donors; another group of 87 male patients in whom a PSA assay was performed prospectively at the first urology outpatients visit. The two PSA assay techniques gave different results, but the values obtained by these two methods were not discordant. It is therefore possible to define a coefficient of proportionality of 1.47 regardless of the PSA concentration or the urological disease considered (EIA Biotrol x 1.47 = RIA Baxter).
Collapse
|
48
|
The fasting test in paediatrics: application to the diagnosis of pathological hypo- and hyperketotic states. Eur J Pediatr 1990; 150:80-5. [PMID: 2279514 DOI: 10.1007/bf02072043] [Citation(s) in RCA: 133] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
A 24-h fasting test was performed in 48 control children, in 9 hypoketotic patients with inherited defects of fatty acid oxidation and in 2 hyperketotic patients with inherited defects of ketolysis. The control group was then divided into three age groups on the basis of different adaptation to fasting. Concentrations of blood glucose, lactate, free fatty acids (FFA), 3-hydroxybutyrate, acetoacetate and carnitine were measured after 15 h, 20 h and 24 h of fasting. Significant negative correlations were found in the control group between plasma total ketone bodies (KB) and plasma glucose (P less than 0.001), plasma carnitine (P less than 0.005) and the amplitude of glycaemic response to glucagon at the end of the fast (P less than 0.01). FFA/KB ratio and the product of final fasting values of glucose and ketones were useful to differentiate between hypoketotic or hyperketotic patients and normal subjects. In children with a suspected or definite hyperketotic or hypoketotic disorder, a fasting test must only be performed in healthy patients, in good nutritional condition with non-diagnostic basal biochemical investigations. Carefully supervised fasting should be continued sufficiently to allow ketogenesis and ketolysis to become activated.
Collapse
|
49
|
European Multicentre Evaluation of the ESAT 6660. JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY. ZEITSCHRIFT FUR KLINISCHE CHEMIE UND KLINISCHE BIOCHEMIE 1990; 28:435-43. [PMID: 2212961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The analytical performance of the glucose analyser ESAT 6660 from Eppendorf was studied according to the ECCLS guidelines and partly according the SFBC protocol in a multicentre evaluation involving laboratories from three European countries. The glucose determination in serum and in haemolysate was studied. The following results were obtained. 1. The precision was as good as or better than the precision of the comparison instruments. The coefficients of variation were between 1.1 and 3.4% for the between-days imprecision and between 0.35 and 1.45% for the within-run imprecision experiment. 2. The recovery of control sera values compared with the hexokinase method was between 94.3 and 102.6%. 3. With patient specimens as good agreement was found between the results obtained with the ESAT 6660 and the different comparison instruments (ASTRA, Hitachi 737 and ACP 5040). 4. A drift effect of 1.1-2.3% occurred in 5 of 21 experiments, depending on the individual enzyme membrane. 5. Sample carry-over was not observed. 6. A linearity between 0.5 and 50 mmol/l was found, exceeding the manufacturer's claims. 7. Several different endogenous and exogenous interferences were investigated. No interfering effect was detected for endogenous substances. A positive interference was observed by ascorbic acid at a concentration above 350 mg/l. 8. The practicability of the instrument was judged as very good. It was considered as a disadvantage that the instrument is not capable of piercing sample lids. Also the numeration of samples is not very convenient.
Collapse
|
50
|
Multicentre evaluation of the Boehringer Mannheim/Hitachi 717 analysis system. JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY. ZEITSCHRIFT FUR KLINISCHE CHEMIE UND KLINISCHE BIOCHEMIE 1990; 28:261-9. [PMID: 2193104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
We conducted an European multicentre trial to assess the performance of the new Boehringer Mannheim/Hitachi 717 analysis system. The photometer response was linear up to an absorbance of 2.8. The maximal CV of photometric imprecision was 0.5% for the wavelength pair 340/405 nm within the absorbance range 0.9 to 2.4. For the 13 analytes in our study, mean within-run imprecision was less than 2%, and mean between-day imprecision less than 2.5%. The results obtained with the Hitachi 717 instrument correlated closely with those of comparison instruments. Linearity for the various tests was high and exceeded the manufacturer's claims. No drift was detected during an 8-hour work period; carry over could not be detected under the chosen experimental conditions. The new instrument was readily accepted by the evaluators because of its ease of handling and simple daily maintenance.
Collapse
|