1
|
Translucency of Lithium-Based Silicate Glass-Ceramics Blocks for CAD/CAM Procedures: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6441. [PMID: 37834578 PMCID: PMC10573117 DOI: 10.3390/ma16196441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/20/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023]
Abstract
Amid chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) has been steadily increasing. This review aims to report on the translucency of these materials and the variables used to measure it. An electronic search was performed within the PubMed database within the period between 2 June 2011 and 11 September 2022. English-language papers investigating the translucency of IPS e.max CAD, Celtra Duo, Suprinity PC, Initial LiSi Block, Amber Mill, N!ce, and CEREC Tessera LSGC CAD/blocks were included in the search strategy. After an initial retrieval of 160 papers, the application of exclusion criteria, and the screening of abstracts and then of full texts, 33 papers were included in the study. The retrieved materials, with different degrees of translucency (LT, HT), were IPS e.max CAD (n = 33), Suprinity PC (n = 8), and Celtra Duo (n = 1). Concerning the examined colors, the most used was A2 (n = 20), followed by A1 (n = 8) and A3 (n = 2). The translucency parameter (TP) was the most used method (n = 30) with respect to the contrast ratio (CR) (n = 11) to assess translucency. Five papers measured both. Several specimens' thicknesses (0.5-4 mm) were investigated, with 1 mm (n = 23) being the most frequently analyzed. While a general tendency could be identified, conflicting results among different papers were reported.
Collapse
|
2
|
Flexural Strength of CAD/CAM Lithium-Based Silicate Glass-Ceramics: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4398. [PMID: 37374581 DOI: 10.3390/ma16124398] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 06/01/2023] [Accepted: 06/09/2023] [Indexed: 06/29/2023]
Abstract
Amongst chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) for indirect restorations has recently been increasing. Flexural strength is one of the most important parameters to consider in the clinical selection of materials. The aim of this paper is to review the flexural strength of LSGC and the methods used to measure it. METHODS The electronic search was completed within PubMed database from 2 June 2011 to 2 June 2022. English-language papers investigating the flexural strength of IPS e.max CAD, Celtra Duo, Suprinity PC, and n!ce CAD/CAM blocks were included in the search strategy. RESULTS From 211 potential articles, a total of 26 were identified for a comprehensive analysis. Categorization per material was carried out as follows: IPS e.max CAD (n = 27), Suprinity PC (n = 8), Celtra Duo (n = 6), and n!ce (n = 1). The three-point bending test (3-PBT) was used in 18 articles, followed by biaxial flexural test (BFT) in 10 articles, with one of these using the four-point bending test (4-PBT) as well. The most common specimen dimension was 14 × 4 × 1.2 mm (plates) for the 3-PBT and 12 × 1.2 mm (discs) for BFT. The flexural strength values for LSGC materials varied widely between the studies. SIGNIFICANCE As new LSGC materials are launched on the market, clinicians need to be aware of their flexural strength differences, which could influence the clinical performance of restorations.
Collapse
|
3
|
Effect of Different Artificial Staining Procedures on the Color Stability and Translucency of a Nano-Hybrid Resin-Based Composite. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2336. [PMID: 36984216 PMCID: PMC10058860 DOI: 10.3390/ma16062336] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/07/2023] [Accepted: 03/13/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND To evaluate the effect of different experimental staining procedures on color stability and translucency of a nano-hybrid resin-based composite (RBC). METHODS Forty-eight cylindrical-shaped specimens (10 × 2 mm) were prepared with a nano-hybrid RBC (Clearfil Majesty ES-2) and randomly divided in four groups according to the experimental staining procedure: G1) static immersion in a staining solution (coffee) (44 ± 1 °C); G2) staining cycling between coffee (44 ± 1°C) and distilled water (37 ± 1°C) with an experimental staining machine based on Arduino, an Open Source hardware development platform; G3) staining cycles as in G2 + brushing with a low abrasive toothpaste (Relative Dentin Abrasion RDA = 30) (Elmex Sensitive Professional); G4) staining cycles as in G3, with brushing performed with a very strong abrasive toothpaste (RDA = 90) (Lacult Active). Color parameters were recorded at the baseline (T0) after staining procedures (T1) and repolishing (T2) using a spectrophotometer. Color change (∆E00) and translucency (TP, CR) were evaluated. Data were statistically analyzed (p < 0.05). RESULTS For ∆E00 after staining, Group 1 showed the highest color change and Group 3 the lowest. All groups were significantly different (p < 0.001) except for Group 2 vs. Group 4; after repolishing, Group 1 was significantly higher than Group 3 (p < 0.001), Group 2 (p < 0.001), and Group 4 (p = 0.003); Group 2 was higher than Group 3 (p < 0.001). For TP variable, after staining procedures, Group 2 was significantly higher than all other groups (p < 0.001), and Group 1 was significantly higher than Group 3 (p < 0.001) and Group 4 (p = 0.007). After repolishing, Group 4 was significantly lower than Group 3 (p = 0.008) and Group 2 (p = 0.027). Repolishing procedure significantly reduced color parameters. CONCLUSIONS The investigated staining procedure induced significant differences in color stability and translucency. The use of a very strong abrasive toothpaste (RDA = 90) induced higher color change than a low abrasive one (RDA = 30). Repolishing procedures are able to partially reduce color change induced by artificial staining procedures.
Collapse
|
4
|
Clinically Relevant Properties of 3D Printable Materials for Intraoral Use in Orthodontics: A Critical Review of the Literature. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16062166. [PMID: 36984045 PMCID: PMC10058724 DOI: 10.3390/ma16062166] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 03/01/2023] [Accepted: 03/07/2023] [Indexed: 06/05/2023]
Abstract
The review aimed at analyzing the evidence available on 3D printable materials and techniques used for the fabrication of orthodontic appliances, focusing on materials properties that are clinically relevant. MEDLINE/PubMed, Scopus, and Cochrane Library databases were searched. Starting from an initial retrieval of 669 citations, 47 articles were finally included in the qualitative review. Several articles presented proof-of-concept clinical cases describing the digital workflow to manufacture a variety of appliances. Clinical studies other than these case reports are not available. The fabrication of aligners is the most investigated application of 3D printing in orthodontics, and, among materials, Dental LT Clear Resin (Formlabs) has been tested in several studies, although Tera Harz TC-85 (Graphy) is currently the only material specifically marketed for direct printing of aligners. Tests of the mechanical properties of aligners materials lacked homogeneity in the protocols, while biocompatibility tests failed to assess the influence of intraoral conditions on eluents release. The aesthetic properties of 3D-printed appliances are largely unexplored. The evidence on 3D-printed metallic appliances is also limited. The scientific evidence on 3D printable orthodontic materials and techniques should be strengthened by defining international standards for laboratory testing and by starting the necessary clinical trials.
Collapse
|
5
|
Color stability of resin-based composites exposed to smoke. A systematic review. J ESTHET RESTOR DENT 2023; 35:309-321. [PMID: 36602255 DOI: 10.1111/jerd.13009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/06/2022] [Accepted: 12/23/2022] [Indexed: 01/06/2023]
Abstract
OBJECTIVE To conduct a systematic review on color stability of dental resin-based composites (RBC) exposed to conventional and electronic cigarettes. MATERIALS AND METHODS In vitro studies reporting on the color stability of RBC exposed to conventional cigarettes or to e-cigarettes: both Tobacco Heating Systems (THS) and Electronic Nicotine Delivery Systems (ENDS). The quality of the included studies was assessed with the QUIN tool (risk-of-bias tool for assessing in vitro studies conducted in dentistry). A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) was performed on four (n = 4) databases (Embase, Medline, Scopus, Web of Science) for articles published until March 28th, 2022. RESULTS Of the 365 screened articles, 13 were included in this review. All the included articles analyzed conventional cigarette smoke (CS), four analyzed Electronic Nicotine Delivery Systems (ENDS) and two Tobacco Heating Systems (THS). In terms of study design, smoke exposure time, smoke flow, type and number of cigarettes a high variability was reported. CONCLUSIONS The available evidence suggests that CS smoke significantly affects color stability. Electronic cigarettes show less color change that seems to be easily recovered under clinical acceptability thresholds, although evidence is scarce. CLINICAL SIGNIFICANCE Clinicians should be aware, and should therefore warn their patients, that RBCs are subjected to irreversible color change if exposed to smoke. Electronic cigarettes (both ENDS and THS) induce less color change that can be recovered with repolishing or whitening procedures.
Collapse
|
6
|
Influence of Thickness of Opaque Porcelain and Alloy Color on the Final Color of Porcelain-Fused-to-Metal Restorations. MATERIALS (BASEL, SWITZERLAND) 2023; 16:457. [PMID: 36614796 PMCID: PMC9821996 DOI: 10.3390/ma16010457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 12/14/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
Despite the advent of metal-free solutions, porcelain-fused-to-metal restorations (PFM) are still widely used. Particularly for the latest ceramic systems, scarce information is present in the scientific literature about the ideal opaque layer thickness and the alloy color impact to achieve the desired final color of PFM restorations. This study aimed to evaluate the influence of opaque thickness variation layered on different metal alloys on the final color of PFM restorations. Opaque porcelain of one metal−ceramic system (VITA VM13) was layered in four different thicknesses (0.10 mm, 0.15 mm, 0.20 mm, and 0.25 mm) on three differently colored dental alloys: a gold−platinum alloy (yellowish), a gold−palladium alloy (light grayish), and a nickel−chromium alloy (dark grayish). The veneering porcelain layered over the opaque was kept constant (Base Dentine 0.45 mm, Transpa Dentine 0.50 mm, and Enamel 0.20 mm). Sixty specimens were fabricated, five samples for each combination of alloy/opaque thickness. The color difference (ΔE) between specimen and reference was measured using a clinical spectrophotometer. The two-way ANOVA revealed that the thickness of both the opaque (p < 0.001) and the metal alloy (p < 0.001) significantly influenced the ΔE values. Gray-colored alloys covered by a 0.10 mm thick opaque layer enabled the closest color match, whereas this occurred for yellow-color alloys covered by a 0.15 mm thick opaque layer. In contrast, the samples covered by a 0.25 mm thick opaque layer obtained the worst ΔE.
Collapse
|
7
|
Factory Crystallized Silicates for Monolithic Metal-Free Restorations: A Flexural Strength and Translucency Comparison Test. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7834. [PMID: 36363425 PMCID: PMC9657079 DOI: 10.3390/ma15217834] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/14/2022] [Accepted: 10/26/2022] [Indexed: 06/16/2023]
Abstract
Flexural strength (FS) and translucency (Contrast Ratio-CR) of three different factory crystallized silica-based glass ceramics, Celtra Duo (CD), N!ce (NI) and Li-Si Block, a lithium disilicate, IPS e.max CAD (LD), and a leucite-reinforced feldspathic ceramic, Empress CAD (EM), in two different translucencies (HT and LT) for use in chairside dental restorations have been compared. CAD blocks of the materials were cut into beams and tiles and processed following manufacturers’ instructions. The beams were tested (3-PBT) to determine flexural strength, Weibull characteristic strength, and Weibull modulus; and tiles were tested to determine CR. All data were statistically analyzed. In addition, SEM analysis of the materials was performed. Differences in flexural strength (FS) and translucency (CR) between the materials were found to be statistically significant. FS decreased as follows (MPa): LDHT 350.88 ± 19.77 (a) = LDLT 343.57 ± 18.48 (a) > LSLT 202.15 ± 17.41 (b) = LSHT 196.93 ± 8.87 > NIHT 186.69 ± 13.06 (c) = CDLT 184.73 ± 13.63 (c) = CDHT 174.15 ± 21.76 (c) = NILT 172.12 ± 11.98 (c) > EMHT 131.16 ± 13.33 (e) = EMLT 127.65 ± 11.09. CR decreased as follows (mean ± sd): CDLT 74.1 ± 1.1 (a); LSLT 74.0 ± 1.1 (ab); NILT 73.3 ± 0.8 (ab); EMLT 73.0 ± 1.5 (ab); NIHT 72.4 ± 1.0 (bc); LDLT 71.3 ± 1.1 (bc); LTHT 65.2 ± 0.9 (de); LSHT 63.8 ± 1.1 (def); EMHT 636 ± 1.2 (ef); CDHT 62.2 ± 0.8 (f). Our findings show that factory-crystallized lithium silicate glass ceramics fulfill ISO standards for Classes 1 and 2. Therefore, they can be considered viable alternatives to produce single-unit restorations with a chairside procedure not requiring thermal treatment.
Collapse
|
8
|
In vitro procedures for color stability evaluation of dental resin-based composites exposed to smoke: A scoping review. Dent Mater J 2022; 41:791-799. [PMID: 36070929 DOI: 10.4012/dmj.2022-106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The objective of this study was to review the experimental in vitro procedures employed to assess the color stability of resin-based composites exposed to smoke. A literature search was performed on four databases (Pubmed, Scopus, Embase, and Web of Science). The quality of the included papers was assessed with the Cochrane risk-of-bias tool (RoB 2). In total, 25 studies were selected for full-text reading, from which 12 were included in the review. The assessed variables were: dimensions, shape, time before exposure, finishing, smoke-type, exposure time, brushing simulation, color, measuring system, repolishing. A disk-shaped specimen was used in most studies (n=10) with a 2 mm thickness (n=7) in custom made devices equipped with vacuum pumps or in Vitrocell systems. Spectrophotometers were the most used devices (n=11). Color differences were quantified with ΔE (n=12), ΔE00 (n=1). The large variety of staining procedures suggests the need for standardization.
Collapse
|
9
|
Effects of Substrate and Cement Shade on the Translucency and Color of CAD/CAM Lithium-Disilicate and Zirconia Ceramic Materials. Polymers (Basel) 2022; 14:1778. [PMID: 35566944 PMCID: PMC9101095 DOI: 10.3390/polym14091778] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 04/12/2022] [Accepted: 04/12/2022] [Indexed: 01/27/2023] Open
Abstract
The aim of this in vitro study was to evaluate the effects of substrate and cement shades on the translucency and color of lithium-disilicate and zirconia CAD/CAM materials. Two light-cured resin cements (RelyX Veneer Cement; 3M; Choice 2 Veneer Cement; Bisco Dental) with a standardized thickness (0.1 mm) were tested in combination with two different monolithic CAD/CAM materials (E-Max CAD (LI2SI2O5); Ivoclar Vivadent; Katana (ZrO2); Kuraray-Noritake Dental) on two different colored composite substrates used as a dentin (Filtek Supreme XTE; 3M); for a total of 12 combinations (n = 10). The specimens’ color was measured with a spectrophotometer (Spectroshade; MHT). Measurements were taken using the CIELAB color coordinate system (L*a*b*) against black and white backgrounds. L*a*b* values were statistically analyzed for the variables Substrate, Ceramic, and Cement by applying a Three-Way ANOVA followed by the Tukey Test for post-hoc comparison (p < 0.05). Translucency Parameter (TP) and Constant Ratio (CR) were assessed to evaluate translucency; acceptability and perceptibility thresholds (ΔE00 1.8 and 0.8) were used. Statistically significant influence was found for factors ceramic material, cement shade, and substrate color (p < 0.05). Unacceptable color differences were reported for Li2Si2O5. Opacity was significantly higher when white opaque cement shade was employed. Ceramic type and cement shade significantly influenced L*a*b* color coordinates. The final translucency and color of ceramic restorations can, therefore, be influenced by ceramic material, cement shade, and substrate color.
Collapse
|
10
|
Color stability of resin-based composites: Staining procedures with liquids-A narrative review. J ESTHET RESTOR DENT 2022; 34:865-887. [PMID: 35396818 DOI: 10.1111/jerd.12912] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Revised: 01/30/2022] [Accepted: 03/24/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE The objective of this study was to review the experimental staining procedures performed in in-vitro studies for evaluating color stability of resin-based composites used for direct restorations. OVERVIEW A review was performed with the purpose to identify in vitro procedures carried out to establish staining and color stability of resin-based composites used for direct restorations. A literature search was performed on four online databases (PubMed, Scopus, Embase and Web of Science) for articles published from January 1st 2001 till March 20th 2021, using a combination of free words and Medical Subject Headings (MESH) terms: "Composite Resins" AND "Color Stability" OR "Staining." Two reviewers screened titles and/or abstracts of 1728 unique studies. In total, 208 studies were selected for full-text reading, from which 178 were included in the review. The assessed variables were specimen dimensions, shape, and surface finishing; time before immersion; staining media type, dwell time, temperature and renewal interval; type of composite; color and translucency assessment parameters and measuring system. One hundred and seventy-eight articles analyzed color stability with staining liquids. Coffee was the most used staining medium (n = 102), followed by tea (n = 61), and red wine (n = 55). A disc-shaped specimen was used in most studies (n = 170) with a 2 mm thickness (n = 116). Spectrophotometers were the most used color assessment devices (n = 154), followed by colorimeters (n = 17). Color differences were quantified with ΔE (n = 154), ΔE00 (n = 23). Acceptability and or perceptibility thresholds were also taken into consideration (n = 126). CONCLUSIONS The large variety of staining procedure suggests the need for standardization. CLINICAL SIGNIFICANCE Aesthetic failure due to discoloration is a relevant clinical problem. Evaluating benefits and drawbacks of resin based composites artificial staining procedures will improve to predict materials clinical performances.
Collapse
|
11
|
External Marginal Gap Variation and Residual Fracture Resistance of Composite and Lithium-Silicate CAD/CAM Overlays after Cyclic Fatigue over Endodontically-Treated Molars. Polymers (Basel) 2021; 13:polym13173002. [PMID: 34503042 PMCID: PMC8434150 DOI: 10.3390/polym13173002] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 08/27/2021] [Accepted: 08/28/2021] [Indexed: 11/16/2022] Open
Abstract
The purpose of this in vitro study was to evaluate the external marginal gap variation with a 3D quantitative method and the residual fracture resistance after cyclic fatigue in endodontically treated molars restored with overlays of different materials, with and without fiber posts-supported buildups. Forty-eight human maxillary molars were selected, endodontically treated, prepared with standardized MOD cavities and randomly allocated into 6 study groups considering the "core strategy" (build-up with composite resin; build-up with composite resin supported by a fiber post); and the "restorative material" of the indirect adhesive overlay (GrandioBlocks, Voco; Cerasmart, GC; CeltraDuo, Dentsply). All procedures were executed according with manufacturers guidelines. Micro-CT analysis prior and after cyclic fatigue were executed, followed by scanning electron microscope analysis and fracture resistance test. The Two-Way ANOVA analysis showed that interfacial gap progression was significantly influenced by the "core strategy" (p < 0.01) but not of "restorative material" (p = 0.59). Concerning fracture resistance, "restorative material" was statistically significant (p < 0.01), while "core strategy" (p = 0.63) and the interaction (p = 0.84) were not. In conclusion, the fiber post presence within the build-up promoted a lower interfacial gap opening after fatigue, evaluated through micro-CT scans. In terms of fracture resistance, teeth restored with Cerasmart and Celtra Duo were statistically similar, but superior to GrandioBlocks.
Collapse
|
12
|
Effect of Finishing Systems on Surface Roughness and Gloss of Full-Body Bulk-Fill Resin Composites. MATERIALS 2020; 13:ma13245657. [PMID: 33322405 PMCID: PMC7763061 DOI: 10.3390/ma13245657] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/03/2020] [Accepted: 12/07/2020] [Indexed: 11/16/2022]
Abstract
Background: In this study, we assess the effect produced on roughness and gloss of full-body bulk-fill materials by different finishing and polishing systems. Methods: Four full-body bulk-fill materials were tested: SonicFill2 (SF), Filtek Bulk Fill Posterior Restorative (FB), Tetric EvoCeram bulk-fill (EC), and Fill-Up! (FU). Sixty discs per material (2 mm in thickness and 7 mm in diameter) were obtained and randomly assigned (n = 15) to four finishing and polishing methods: Sof-Lex Spiral Wheels (SW), HiLusterPLUS (HL), Astropol (AP), and Opti1Step (OS). Surface roughness and gloss were then measured. Results: For roughness, material and surface treatment were significant factors (p < 0.001) with SF = FB = EC < FU and AP < SW < HL = OS. Material and surface treatment had a significant effect also on gloss (p < 0.001), with SF > FB = EC > FU and SW > AP > HL > OS. Conclusions: The tested combinations of bulk-fill and polishing systems provided clinically acceptable results with regard to roughness, while the outcome was poor for gloss. Multistep finishing/polishing systems were able to produce smoother surfaces on full-body bulk-fill materials compared to simplified ones.
Collapse
|
13
|
Flexural resistance of CAD-CAM blocks. Part 3: Polymer-based restorative materials for permanent restorations. AMERICAN JOURNAL OF DENTISTRY 2020; 33:243-247. [PMID: 33017526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
PURPOSE Concurrently with the growing interest in CAD-CAM systems, several new materials of different chemical nature have become available. As an alternative to ceramics, numerous polymer-based materials have recently been proposed for permanent prosthetic restorations. Aim of this study was to test the CAD-CAM polymer-based materials available on the market, comparing mean flexural strength, Weibull characteristic strength and Weibull modulus. METHODS Seven types of polymer-based blocks were tested: Lava Ultimate, 3M; Brilliant Crios, Coltene; Cerasmart, GC; Block HC, Shofu; Katana Avencia, Noritake; Grandio Blocs, Voco; Tetric CAD, and Ivoclar-Vivadent. Specimens were cut out from blocks, finished, polished, and tested in a three-point bending test apparatus until failure (n=30). Flexural strength, Weibull characteristic strength, and Weibull modulus were calculated. Flexural strength data were statistically analyzed. ANOVA on Ranks was applied, followed by the Dunn's test for post hoc comparisons (P= 0.05). RESULTS Flexural strength values (MPa) were measured (mean±standard deviation). Different letters in parentheses label statistically significant differences: Grandio Blocs 266±24(a), Brilliant Crios 259±21(ab); Tetric CAD 254±15(ab); Katana Avencia 241±29(bc); Cerasmart 221±24(cd); Lava Ultimate 196±23(de); Block HC 139±10(e). All the tested materials had flexural strengths greater than 100 MPa, thereby satisfying the requirements of ISO standards for polymer-based materials. For all the tested materials the Weibull characteristic strength was greater than 100 MPa. Weibull modulus ranged between 21.20 (Tetric CAD) and 9.09 (Katana Avencia). CLINICAL SIGNIFICANCE Even though all the CAD-CAM polymer-based materials marketed in blocks tested in the present study satisfy the requirements of ISO standard for polymer-based materials, their flexural resistance differs significantly. The data presented in the study may be helpful to clinicians for selecting the most appropriate materials for each clinical case.
Collapse
|
14
|
Influence of Acid Concentration and Etching Time on Composite Cement Adhesion to Lithium-silicate Glass Ceramics. THE JOURNAL OF ADHESIVE DENTISTRY 2020; 22:175-182. [PMID: 32322838 DOI: 10.3290/j.jad.a44282] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the influence of hydrofluoric acid (HF) concentration and etching time on the microshear bond strength (µSBS) of RelyX Unicem 2 (3M Oral Care) to VITA Suprinity (Vita Zahnfabrik; zirconia-reinforced lithium-silicate glass ceramic: ZLS) and IPS e.max CAD (Ivoclar Vivadent; lithium-disilicate glass ceramic: LD). MATERIALS AND METHODS Forty-eight bars each were fabricated of ZLS and LD with Cerec InLab MC-XL. For each material, 8 groups were formed with respect to etching time (20, 40, 60, 120 s) and HF concentration (4.9% and 9.5%). In each group, after etching and silanization, 15 cylindrical specimens of RelyX Unicem 2 were built up for µSBS testing with a special device. Data were analyzed using three-way ANOVA. Failure modes were assessed using an optical stereomicroscope, classified as adhesive, cohesive in resin or ceramic, or mixed. Failure modes were statistically analyzed using Fisher's Exact Test. One bar per group was prepared for SEM observation of the etched surface. RESULTS ZLS showed significantly higher bond strengths than LD (p < 0.001). Etchant concentration was an influential factor with superior strengths after 4.9% HF etching (p = 0.009). Etching time did not significantly affect adhesion (p = 0.066). The material-etching interaction was statistically significant (p = 0.004). Particularly for ZLS, 4.9% HF etching obtained significantly higher bond strengths than did 9.5%. By using 4.9% HF, adhesion was significantly higher on ZLS than on LD. CONCLUSION Material and HF concentration influenced the adhesion between RelyX Unicem 2 composite cement and lithium-silicate glass ceramics. Etching time was not an influential factor. The use of 4.9% HF for 20 s proved to be the most effective etching treatment of the intaglio surface.
Collapse
|
15
|
Cement opacity and color as influencing factors on the final shade of metal-free ceramic restorations. J ESTHET RESTOR DENT 2020; 34:423-429. [PMID: 32282998 DOI: 10.1111/jerd.12587] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 03/10/2020] [Accepted: 03/26/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate the influence of opacity and color of luting cements on the final shade of metal-free restorations. MATERIALS AND METHODS Five resin cement colors in combination with four different thicknesses of CAD/CAM ceramic materials were tested, and a composite substrate was used as dentin color reference (n = 3). Specimen color was measured with a spectrophotometer equipped with an integrating sphere before and after cementation (CIELAB). Cement and ceramic color and opacity (TP) were assessed by measuring the tested ceramic thickness as a 1-mm thick disk for each of the cement shades. The differences in color were evaluated (ΔE00 ). Data were statistically analyzed by a Two-Way ANOVA followed by the Tukey Test for post-hoc comparison (P < .05) and multiple comparison Pearson's test (P < .05); the acceptability and perceptibility threshold were evaluated. RESULTS Statistically significant influence was found for factors ceramic thickness and cement shade (P < .001). Perceptible and unacceptable color changes were induced on the final restoration by resin cements (ranging from ΔE00 = 0.69 ± 0.54 to ΔE00 = 5.53 ± 0.46), the correlation between factors became strong (r2 > 0.6) in case of mismatch between color and translucency of cement and ceramic. Only the clear shade in combination with the thickest ceramic, resulted in an imperceptible color change (ΔE00 = 0.69 ± 0.54). CONCLUSIONS The final shade of ceramic restorations can be influenced by resin cements; the magnitude of influence is related to the cement optical properties. CLINICAL SIGNIFICANCE In order to influence the final shade of a ceramic restoration, a cement more opaque than the restorative material should be used. Conversely, in the case of a fitting shade of the restoration, a cement more translucent than the restoration should be used to avoid undesired changes.
Collapse
|
16
|
Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives. Korean J Orthod 2019; 49:404-412. [PMID: 31815108 PMCID: PMC6883210 DOI: 10.4041/kjod.2019.49.6.404] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 09/03/2019] [Accepted: 09/09/2019] [Indexed: 11/10/2022] Open
Abstract
Objective To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. Methods Two types of PMMA blocks were tested: CAD-Temp® (VITA) and Telio® CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) CADTemp®/SU; (2) CAD-Temp®/AP; (3) CAD-Temp®/XTP; (4) Telio® CAD/SU; (5) Telio® CAD/AP; (6) Telio® CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit (100 mm) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. Results On CAD-Temp® significantly higher bracket bond strengths than on Telio® CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. Conclusions Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.
Collapse
|
17
|
Abstract
This study assessed push-out strength, cement layer thickness, and interfacial nanoleakage of luted fiber posts fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology after use of 1 of 3 scanning techniques, namely, direct scanning of the post space (DS), scanning of a polyether impression of the post space (IS), and scanning of a plaster model of the post space (MS). Thirty premolars were randomly assigned to three groups corresponding to the scanning technique. Posts were computer-designed and milled from experimental fiber-reinforced composite blocks. The mean (±SD) values for push-out strength and cement thickness were 17.1 ± 7.7 MPa and 162 ± 24 μm, respectively, for DS, 10.7 ± 4.6 MPa and 187 ± 50 μm for IS, and 12.0 ± 7.2 MPa and 258 ± 78 μm for MS specimens. Median (interquartile range) interfacial nanoleakage scores were 3 (2-4) for DS, 2.5 (2-4) for IS, and 3 (2-4) for MS. Post retention was better for fiber posts fabricated by DS technique than for those fabricated by IS and MS. Cement thickness did not differ between DS and IS specimens, but the cement layer was significantly thicker in the MS group than in the other two groups. Scanning technique did not affect sealing ability, as the three groups had comparable nanoleakage values.
Collapse
|
18
|
Effect of Finishing and Polishing on Roughness and Gloss of Lithium Disilicate and Lithium Silicate Zirconia Reinforced Glass Ceramic for CAD/CAM Systems. Oper Dent 2018; 43:90-100. [DOI: 10.2341/16-381-l] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
To assess the efficacy of dedicated finishing/polishing systems on roughness and gloss of VITA Suprinity and IPS e.max CAD.
Method:
A total of 24 blocks of Suprinity and 24 of e.max were cut into a wedge shape using an InLab MC-XL milling unit. After crystallization, the 24 Suprinity wedges were divided into four subgroups: group A.1: Suprinity Polishing Set Clinical used for 30 seconds and group A.2: for 60 seconds; group A.3: VITA Akzent Plus Paste; and group A.4: spray. The 24 e.max wedges (group B) were divided into four subgroups according to the finishing procedure: group B.1: Optrafine Ceramic Polishing System for 30 seconds and group B.2: for 60 seconds; group B.3: IPS e.max CAD Crystall/Glaze paste; and group B.4: spray. After finishing/polishing, gloss was assessed with a glossmeter and roughness evaluated with a profilometer. Results were analyzed by applying a two-way analysis of variance for gloss and another for roughness (α=0.05). One specimen per each subgroup was observed with a scanning electron microscope.
Results:
For roughness, materials and surface were significant factors (p<0.001). Suprinity exhibited significantly lower roughness than e.max. Also the Material-Surface Treatment interaction was statistically significant (p=0.026). For gloss, both material and surface treatment were significant factors (p<0.001). VITA Suprinity showed significantly higher gloss than e.max. Also the Material-Surface Treatment interaction was statistically significant (p<0.001).
Conclusions:
Manual finishing/polishing for 60 seconds and glazing paste are the most effective procedures in lowering the roughness of CAD/CAM silica-based glass ceramics. Manual finishing/polishing for 60 seconds allows milled silica-based glass ceramics to yield a higher gloss. VITA Suprinity displayed higher polishability than IPS e.max CAD.
Collapse
|
19
|
Performance of CAD/CAM fabricated fiber posts in oval-shaped root canals: An in vitro study. AMERICAN JOURNAL OF DENTISTRY 2017; 30:248-254. [PMID: 29178727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
PURPOSE To assess the push-out strength, the cement layer thickness and the interfacial nanoleakage of prefabricated fiber posts, CAD/CAM fiber posts and metal cast posts cemented into oval-shaped root canals. METHODS Oval-shaped post spaces were prepared in 30 single-rooted premolars. Roots were randomly assigned to three groups (n=10), according to the post type to be inserted: Group 1: Prefabricated fiber post (D.T. Light-Post X-RO Illusion); Group 2: Cast metal post; Group 3: CAD/CAM-fabricated fiber post (experimental fiber blocks). In Group 3, post spaces were sprayed with scan powder (VITA), scanned with an inEos 4.2 scanner, and fiber posts were milled using an inLab MC XL CAD/CAM milling unit. All posts were cemented using Gradia Core dual-cure resin cement in combination with Gradia core self-etching bond (GC). After 24 hours, the specimens were sectioned perpendicular to the long axis into six 1 mm-thick sections, which were differentiated by the root level. Sections from six roots per group were used to measure the cement thickness and subsequently for the thin-slice push-out test, whereas the sections from the remaining four teeth were assigned to interfacial nanoleakage test. The cement thickness around the posts was measured in micrometers (µm) on the digital images acquired with a digital microscope using the Digimizer software. Thin-slice push-out test was conducted using a universal testing machine at the crosshead speed of 0.5 mm/minute and the bond strength was expressed in megaPascals (MPa). The interfacial nanoleakage was observed under light microscope and quantified by scoring the depth of silver nitrate penetration along the post-cement-dentin interfaces. The obtained results were statistically analyzed by Kruskal-Wallis ANOVA, followed by the Dunn's Multiple Range test for post hoc comparisons. The level of significance was set at P< 0.05. RESULTS Statistically significant differences were found among the groups in push-out bond strength, cement thickness and interfacial nanoleakage (P< 0.05). CAD/CAM-fabricated fiber posts achieved retention that was comparable to that of cast metal posts and significantly higher than that of prefabricated fiber posts. The cement layer thickness around CAD/CAM-fabricated fiber posts was significantly lower than around prefabricated fiber posts, but higher than that around cast metal posts. Root level was not a significant factor for push-out strength in any of the groups, whereas it significantly affected cement layer thickness only in the prefabricated fiber post group. No differences were observed in interfacial nanoleakage between CAD/CAM fabricated and prefabricated fiber posts, while nanoleakage recorded in cast metal posts was significantly lower. CLINICAL SIGNIFICANCE CAD/CAM fabricated fiber posts could represent a valid alternative to traditionally used posts in the restoration of endodontically-treated teeth with oval or wide root canals, offering the advantages of better esthetics, retention, and cement thickness values that are comparable to cast post and cores.
Collapse
|
20
|
Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics. J Adv Prosthodont 2017; 9:257-264. [PMID: 28874992 PMCID: PMC5582091 DOI: 10.4047/jap.2017.9.4.257] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Revised: 12/19/2016] [Accepted: 01/10/2017] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher's Exact Test was applied to the failure analysis data. RESULTS The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.
Collapse
|
21
|
ADM guidance-Ceramics: guidance to the use of fractography in failure analysis of brittle materials. Dent Mater 2017; 33:599-620. [PMID: 28400062 DOI: 10.1016/j.dental.2017.03.004] [Citation(s) in RCA: 105] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 03/09/2017] [Indexed: 11/16/2022]
Abstract
OBJECTIVES To provide background information and guidance as to how to use fractography accurately, a powerful tool for failure analysis of dental ceramic structures. METHODS An extended palette of qualitative and quantitative fractography is provided, both for in vivo and in vitro fracture surface analyses. As visual support, this guidance document will provide micrographs of typical critical ceramic processing flaws, differentiating between pre- versus post sintering cracks, grinding damage related failures and occlusal contact wear origins and of failures due to surface degradation. RESULTS The documentation emphasizes good labeling of crack features, precise indication of the direction of crack propagation (dcp), identification of the fracture origin, the use of fractographic photomontage of critical flaws or flaw labeling on strength data graphics. A compilation of recommendations for specific applications of fractography in Dentistry is also provided. SIGNIFICANCE This guidance document will contribute to a more accurate use of fractography and help researchers to better identify, describe and understand the causes of failure, for both clinical and laboratory-scale situations. If adequately performed at a large scale, fractography will assist in optimizing the methods of processing and designing of restorative materials and components. Clinical failures may be better understood and consequently reduced by sending out the correct message regarding the fracture origin in clinical trials.
Collapse
|
22
|
ADM guidance-Ceramics: Fracture toughness testing and method selection. Dent Mater 2017; 33:575-584. [PMID: 28392020 DOI: 10.1016/j.dental.2017.03.006] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2017] [Accepted: 03/09/2017] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The objective is within the scope of the Academy of Dental Materials Guidance Project, which is to provide dental materials researchers with a critical analysis of fracture toughness (FT) tests such that the assessment of the FT of dental ceramics is conducted in a reliable, repeatable and reproducible way. METHODS Fracture mechanics theory and FT methodologies were critically reviewed to introduce basic fracture principles and determine the main advantages and disadvantages of existing FT methods from the standpoint of the dental researcher. RESULTS The recommended methods for FT determination of dental ceramics were the Single Edge "V" Notch Beam (SEVNB), Single Edge Precracked Beam (SEPB), Chevron Notch Beam (CNB), and Surface Crack in Flexure (SCF). SEVNB's main advantage is the ease of producing the notch via a cutting disk, SEPB allows for production of an atomically sharp crack generated by a specific precracking device, CNB is technically difficult, but based on solid fracture mechanics solutions, and SCF involves fracture from a clinically sized precrack. The IF test should be avoided due to heavy criticism that has arisen in the engineering field regarding the empirical nature of the calculations used for FT determination. SIGNIFICANCE Dental researchers interested in FT measurement of dental ceramics should start with a broad review of fracture mechanics theory to understand the underlying principles involved in fast fracture of ceramics. The choice of FT methodology should be based on the pros and cons of each test, as described in this literature review.
Collapse
|
23
|
Translucent zirconia in the ceramic scenario for monolithic restorations: A flexural strength and translucency comparison test. J Dent 2017; 60:70-76. [PMID: 28274651 DOI: 10.1016/j.jdent.2017.03.002] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2016] [Revised: 02/05/2017] [Accepted: 03/02/2017] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE To compare three different compositions of Yttria-Tetragonal Zirconia Polycrystal (Y-TZP) ceramic and a lithium disilicate ceramic in terms of flexural strength and translucency. METHODS Three zirconia materials of different composition and translucency, Aadva ST [ST], Aadva EI [EI] and Aadva NT [NT](GC Tech, Leuven, Belgium) were cut with a slow speed diamond saw into beams and tabs in order to obtain, after sintering, dimensions of 1.2×4.0×15.0mm and 15.0×15.0×1.0mm respectively. Blocks of IPS e.max CAD LT were cut and crystallized in the same shapes and dimensions and used as a reference group [LD]. Beams (n=15) were tested in a universal testing machine for three-point bending strength. Critical fracture load was recorded in N, flexural strength (σ in MPa), Weibull modulus (m) and Weibull characteristic strength (σ0 in MPa) were then calculated. Tabs (n=10) were measured with a spectrophotometer equipped with an integrating sphere. Contrast Ratios were calculated as CR=Yb/Yw. SEM of thermally etched samples coupled with lineal line analysis (n=6) was used to measure the tested zirconia grain size. Data were statistically analyzed. RESULTS Differences in translucency, flexural strength and grain size were found to be statistically significant. CR increased and flexural strength decreased in the following order ST(σ 1215±190MPa, CR 0.74±0.01)>EI(σ 983±182MPa, CR 0.69±0.01)>NT(σ 539±66MPa, CR 0.65±0.01)>LD (σ 377±39Mpa, CR 0.56±0.02). The average grain size was different for the three zirconia samples with NT(558±38nm)>ST(445±34nm)>EI(284±11nm). CONCLUSIONS The zirconia composition heavily influenced both the flexural strength and the translucency. Different percentages of Yittria and Alumina result in new materials with intermediate properties in between the conventional zirconia and lithium disilicate. Clinical indications for Zirconia Aadva NT should be limited up to three-unit span bridges.
Collapse
|
24
|
Flexural resistance of heat-pressed and CAD-CAM lithium disilicate with different translucencies. Dent Mater 2017; 33:63-70. [DOI: 10.1016/j.dental.2016.10.005] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2016] [Revised: 10/11/2016] [Accepted: 10/24/2016] [Indexed: 11/16/2022]
|
25
|
Effect of Finishing and Polishing on the Surface Roughness and Gloss of Feldspathic Ceramic for Chairside CAD/CAM Systems. Oper Dent 2016; 42:175-184. [PMID: 27723423 DOI: 10.2341/15-174-l] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To evaluate surface roughness and gloss of feldspathic ceramic blocks for chairside CAD/CAM systems before and after finishing and polishing. METHODS VITA Mark II ceramic blocks for the CEREC CAD/CAM system were cut perpendicularly in order to obtain a total of 70 specimens (14 × 18 × 3 mm). The flat surface was roughened using a grinder/polisher with dry 120-grit silicone-carbide paper. Surface roughness and gloss were measured using a digital profilometer (Ra) and a glossmeter (GU), respectively. Specimens were randomly divided into seven groups (n=10) based on the finishing/polishing system as follows: 1) Identoflex NGPorcelain Polisher (INP), 2) Identoflex Diamond Ceramic Polisher (IDP), 3) Hiluster Polishing System (HPS), 4) OptraFine (OF), 5) Identoflex Lucent (IL), 6) VITA Akzent Glaze Spray (AGS), and 7) VITA Shading Paste and Liquid (SPL). Surface analysis was repeated after the finishing/polishing treatment, and the obtained data were compared to the baseline in order to evaluate the ΔRa and ΔGU. Results were statistically analyzed. The surface morphology was observed by scanning electron microscopy. RESULTS The mean surface roughness of polished systems increased in the order (statistical groups designated) SPLa < ILa < OFab < IDPbc < AGSbc < INPbc < HPSc and mean gloss decreased in the order AGSa > SPLa > OFab > ILabc > HPSbcd > INPcd > IDPd. CONCLUSIONS The smoothest surface of CAD/CAM feldspathic ceramic blocks was achieved using the furnace-based glaze systems VITA Akzent Glaze Spray and VITA Shading Paste and Liquid and manual systems Identoflex Lucent and OptraFine.
Collapse
|
26
|
Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color. Int J Oral Maxillofac Implants 2016; 32:393–399. [PMID: 27525517 DOI: 10.11607/jomi.4794] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. MATERIALS AND METHODS Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (≥ 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO₂. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l'Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. RESULTS Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO₂ group. All the patients with thin soft tissues reported color changes that exceeded the critical threshold. CONCLUSION The different abutment materials showed comparable results in terms of influence on soft tissue color. Regarding peri-implant soft tissue thickness, the influence of the tested abutments on soft tissue color became clinically relevant for values ≤ 2 mm.
Collapse
|
27
|
3-Year Randomized Controlled Prospective Clinical Trial on Different CAD-CAM Implant Abutments. Clin Implant Dent Relat Res 2016; 18:1134-1141. [PMID: 26988025 DOI: 10.1111/cid.12418] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 02/08/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND Zirconia abutments were introduced to restore esthetic regions and showed sufficient stability to support implant restorations. Nonetheless, to date the observation periods are shorter than those of titanium abutments. PURPOSE To assess the survival of implant crowns supported by computer aided design-computer aided manufacturing (CAD-CAM) abutments after 3 years. MATERIALS AND METHODS Fifty-six patients were selected for this prospective clinical study. Each patient received at least 1 titanium implant for a total of 89 fixtures. A two-stage surgical technique and no additional soft or hard tissue graft were used. The implants were randomly divided into 3 groups receiving different CAD-CAM abutments: titanium, titanium nitride, and zirconia. Zirconia or metal-ceramic crowns were used as final restorations. Cementation was the baseline and the restorations were checked after 6 months, 1, 2, and 3 years, assessing any mechanical complication. Statistical analyses were performed to evaluate the 3-year success rates. RESULTS Five failures were reported in the zirconia group; all the failed restorations showed fractures of the abutment connection. Four failures occurred in posterior regions and one more occurred while screwing the abutment. Titanium and titanium nitride abutments had significantly higher 3-year success rates than zirconia abutments (p < .05). CONCLUSIONS Atlantis titanium and titanium nitride abutments showed optimal clinical performances after 3 years. Conversely, Atlantis zirconia abutments should be avoided to restore posterior regions.
Collapse
|
28
|
Flexural strength and contrast ratio comparison for translucent zirconia. Dent Mater 2016. [DOI: 10.1016/j.dental.2016.08.093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
29
|
|
30
|
Comparison of Contrast Ratio, Translucency Parameter, and Flexural Strength of Traditional and "Augmented Translucency" Zirconia for CEREC CAD/CAM System. J ESTHET RESTOR DENT 2015; 28 Suppl 1:S32-9. [PMID: 27113296 DOI: 10.1111/jerd.12172] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE Tetragonal zirconia polycrystals (TZP) can be used via CAD/CAM technique as metal replacement for fixed partial dentures. However, its intense white color and high opacity may represent an aesthetic limit. New TZPs with a claimed higher degree of translucency were recently marketed. The aim of the study was to investigate contrast ratio (CR), translucency parameter (TP), flexural strength (σ), Weibull characteristic strength (σ0 ), and Weibull modulus (m) of three "traditional" (IPS e.max Zir-CAD, inCoris ZI, VITA In-Ceram YZ) and two "increased translucency" (inCoris TZI, VITA In-Ceram YZ HT) Y-TZPs. METHODS For flexural strength, ISO 6872:2008 was followed. Bars (N = 40) were cut from pre-sintered blocks. Dense-sintering, finishing, and polishing were performed in order to obtain specimens of 15 × 4 × 1.2 mm. Samples were tested with three-point bending setup in a universal testing machine. For CR and TP, specimens (N = 10) were cut perpendicularly to the long axis from pre-sintered blocks. After the dense-sintering, specimens were finished and polished in order to obtain tiles of 12 × 15 × 1 mm. CR and TP were measured with a spectrophotometer equipped with an integrating sphere. RESULTS No significant difference was found regarding flexural strength. A significant difference was found both for CR and TP among tested groups. VITA In-Ceram YZ HT and inCoris TZI showed the higher translucency. The difference was not statistically significant when compared with VITA In-Ceram YZ, and statistically significant when compared with IPS e.max Zir-CAD and inCoris ZI. CONCLUSION The new "augmented translucency" TZPs showed higher translucency and similar flexural strength than "traditional" TZPs. CLINICAL SIGNIFICANCE Monolithic zirconia use is partially restricted due to the zirconia low translucency. The new "augmented translucency" zirconia showed a modest but perceptible increase in translucency and a similar flexural resistance, thus increasing the clinically suitable thickness range with optimized aesthetic and resistance. (J Esthet RestorDent 28:S32-S39, 2016).
Collapse
|
31
|
Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence. Eur J Orthod 2015; 38:422-8. [DOI: 10.1093/ejo/cjv077] [Citation(s) in RCA: 98] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
32
|
Short-term clinical performance of zirconia single crowns with different framework designs: 3-year clinical trial. AMERICAN JOURNAL OF DENTISTRY 2015; 28:235-240. [PMID: 26437506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
PURPOSE The present prospective clinical study evaluated the influence of coping design on the fracture resistance of CAD/CAM zirconia single crowns layered with dedicated ceramics. METHODS 56 subjects were provided with 90 zirconia single crowns in posterior regions. Tooth preparations were standardized and the abutment teeth were randomly distributed into three groups, according to three different coping designs (flat design, FD; porcelain-fused-to-metal-like crowns, PFM; anatomically-guided, AG). The zirconia cores were produced using a CAD/CAM software and then were hand-layered with dedicated ceramics. All crowns were cemented with a self-adhesive resin luting agent and the patients were recalled for follow-up visits after 1 month, 6 months, 1, 2 and 3 years of clinical service. The function, esthetics and marginal adaptation of the restorations were evaluated. Statistical analyses were performed to evaluate survival and success of the restorations. RESULTS Success rates of 100% were reported in Group 2 and Group 3 while the percentage was 80% in Group 1. Three chippings were noticed in Group 1 (FD) and two crowns needed to be replaced after 3 years, resulting in a survival rate of 93.3%. Group 2 and Group 3 had significantly higher 3-year success rates than Group 1 (P < 0.05). Based on the present clinical results, the following conclusions were drawn: the porcelain-fused-to-metal-like and the anatomically-guided frameworks for zirconia single crowns performed better clinically than the flat designed cores in posterior regions after 3 years; standardized tooth preparations achieved even thicknesses of the bilayered restorations; the proper support given to the veneering ceramic by the correct design of the zirconia framework could significantly reduce the risk of chipping during function.
Collapse
|
33
|
Effect of repeated firings on flexural strength of veneered zirconia. Dent Mater 2015; 31:e151-6. [PMID: 26008238 DOI: 10.1016/j.dental.2015.04.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Revised: 01/16/2015] [Accepted: 04/24/2015] [Indexed: 12/29/2022]
Abstract
OBJECTIVE Chipping and/or delamination represent a clinical failure of porcelain fused to zirconia (PFZ) prostheses. Causes and solutions have not been completely clarified. The present study was aimed at evaluating the effects of number of firings on the flexural strength of PFZ specimen. METHODS Forty-five zirconia specimens in shape of bars were cut, sintered and divided in 3 groups (n=15). Group 1: veneering ceramic was layered "in bulk" and fired. Group 2: veneering ceramic was layered in three layers, individually fired. Group 3: veneering ceramic was layered in five layers, individually fired. Each layer thickness was controlled by the use of calibrated molds. The total veneering ceramic thickness for all the specimens was 1.2mm, and the total thickness of the specimen of 2.0mm. Three-point bending test was performed. Fracture load was recorded in Newton and MPa value was calculated taking into account the bi-layered nature of the specimen. Data were statistically analyzed. RESULTS Specimens obtained with on single firing cycle obtained a statistically significant (p<0.001) lower flexural strength (54.61±8.98MPa) than specimens veneered with 3 or 5 firing cycles. The last two obtained very similar results (77.63±13.17MPa and 73.62±12.38MPa respectively) and the differences was not statistically significant. SIGNIFICANCE In bi-layered PFZ specimen, three to five layers and firings determine higher flexural resistance when compared to a single firing. Thus, a 3-layers veneering procedure is recommended to increase flexural resistance. If a 5-layer procedure is necessary to improve esthetics, it does not decrease flexural resistance.
Collapse
|
34
|
Influence of coloring procedure on flexural resistance of zirconia blocks. J Prosthet Dent 2015; 114:98-102. [PMID: 25858219 DOI: 10.1016/j.prosdent.2015.02.001] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 02/07/2015] [Accepted: 02/09/2015] [Indexed: 10/23/2022]
Abstract
STATEMENT OF PROBLEM The white color of zirconia limits the possibility of a natural-looking restoration. Industrially precolored blocks and green-stage coloring liquids are used to obtain shaded zirconia. Several authors have reported that pigments may negatively affect the mechanical characteristics of the material. PURPOSE The purpose of this in vitro study was to investigate the effect of a recently marketed coloring system on the flexural strength (σ), Weibull characteristic strength (σ0), and Weibull modulus (m) of a zirconia for computer-aided design/computer-aided manufacturing (CAD/CAM) systems. MATERIAL AND METHODS Noncolored white blocks (In-Ceram YZ), industrially precolored blocks (In-Ceram YZ col. LL1p), and green-stage infiltration-shaded blocks in 4 colors (In-Ceram YZ Coloring Liquids) were tested. Industrially precolored specimens (n = 30) were assigned to the PREC group. Noncolored specimens were divided into 5 groups (n = 30). Group CNTR was not treated (control). Groups INF-N, INF-L, INF-M, and INF-I were subject to green-stage infiltration (neutral, light, medium, and intense, respectively). Specimens were tested in a 3-point bending apparatus following ISO 6872:2008 specifications. Data were analyzed by 1-way ANOVA. RESULTS The calculated flexural strengths (MPa) were CNTR 1232.56 ± 103.91; PREC 1215.16 ± 141.42; INF-N 1280.72 ± 160.10; INF-L 1218.92 ± 78.63; INF-M 1153.71 ± 176.80; and INF-I 1248.46 ± 111.73. No statistically significant differences were found among the tested groups (P = .195). CONCLUSIONS Unlike what has been reported for other combinations of zirconia and coloring liquids, the coloring technique tested in the present study did not negatively influence the flexural characteristics of the tested zirconia.
Collapse
|
35
|
Zirconia abutments and restorations: From laboratory to clinical investigations. Dent Mater 2015; 31:e63-76. [DOI: 10.1016/j.dental.2014.11.015] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 11/19/2014] [Accepted: 11/21/2014] [Indexed: 10/24/2022]
|
36
|
Influence of luting agent translucency on fiber post retention. Eur J Oral Sci 2015; 123:116-21. [PMID: 25683864 DOI: 10.1111/eos.12174] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/19/2015] [Indexed: 11/28/2022]
Abstract
The aim was to assess the influence of cement translucency on the retentive strength of luted fiber posts. Twenty extracted human premolars were randomly divided into four equal groups, based on the combinations of materials to be tested. Two post types of the same size, shape, and chemical composition, but different light-transmission properties [Translucent post (TP) and Opaque post (OP)] were selected. The two post types were luted using the etch-and-rinse, light-curing adhesive in combination with two shades of the same resin cement of markedly different light-transmitting ability [Transparent shade (TS) and Opaque shade (OS)]. Early post retention was assessed using the thin-slice push-out test. Post type did not significantly influence post retention; however, cement translucency emerged as a relevant factor in intraradicular cementation, with the TS achieving higher push-out strengths. The between-factor interaction was also statistically significant; specifically, OP-OS yielded significantly lower retentive strengths than all the other groups. Post translucency did not influence post retention, provided that a highly translucent cement was utilized for luting.
Collapse
|
37
|
Fracture resistance of three porcelain-layered CAD/CAM zirconia frame designs. Dent Mater 2014; 30:e163-8. [DOI: 10.1016/j.dental.2014.02.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Accepted: 02/09/2014] [Indexed: 11/30/2022]
|
38
|
Abstract
OBJECTIVES To compare translucency of the ceramic materials (CEREC CAD/CAM). MATERIALS AND METHODS Fifteen ceramic materials for CEREC CAD/CAM system were evaluated: IPS e.max HT/LT/MO, ZirCAD, Empress HT/LT; VITA Mark II, VITA AL; VITA YZ, VITA In-Ceram Spinell/Alumina/Zirconia; and Sirona InCoris AL; Sirona InCoris ZI/TZI. Specimens (0.5-mm and 1.0-mm thick; n = 10 each material) were cut from commercial blocks using a water-cooled diamond saw. Contrast ratio (CR = YB /YW ) was measured using a spectrophotometer with an integrating sphere. Kruskal-Wallis one way analysis of variance was performed followed by Dunn's multiple test for post-hoc. RESULTS CR varied from 0.35 to 1.00 and from 0.48 to 1.00 for 0.5 mm and 1.0 mm thicknesses, respectively. CR increased in the following order: IPS e.max HT (most translucent-least opaque), IPS Empress HT, VITA Mark II, IPS Empress LT, IPS e.max LT, In-Ceram Spinell, IPS e.max MO, VITA YZ, InCoris TZI, IPS e.max ZirCAD, InCoris ZI, In-Ceram Alumina, VITA AL, InCoris AL, and In-Ceram Zirconia (least translucent-most opaque). CONCLUSIONS The null hypothesis has been rejected because tested materials exhibited a wide range of CR. Translucency needs to be taken into account in different clinical situations, including considerations associated with thickness of restoration and/or particular layers. CLINICAL SIGNIFICANCE A wide range of translucency was identified for the ceramic materials tested. This variability has to be taken into account for the selection of the materials in different clinical situations also related to the thickness clinically required.
Collapse
|
39
|
Conformal field theories in fractional dimensions. PHYSICAL REVIEW LETTERS 2014; 112:141601. [PMID: 24765941 DOI: 10.1103/physrevlett.112.141601] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Indexed: 06/03/2023]
Abstract
We study the conformal bootstrap in fractional space-time dimensions, obtaining rigorous bounds on operator dimensions. Our results show strong evidence that there is a family of unitary conformal field theories connecting the 2D Ising model, the 3D Ising model, and the free scalar theory in 4D. We give numerical predictions for the leading operator dimensions and central charge in this family at different values of D and compare these to calculations of ϕ4 theory in the ϵ expansion.
Collapse
|
40
|
The influence of cement filler load on the radiopacity of various fibre posts ex vivo. Int Endod J 2014; 48:60-7. [PMID: 24611944 DOI: 10.1111/iej.12275] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 02/22/2014] [Indexed: 11/28/2022]
Abstract
AIM To verify whether the filler load of luting agents influences the radiopacity of intraradicularly placed posts. METHODOLOGY Digital radiographs of the following posts were taken: RelyX Fiber Post (3M ESPE), GC Fiber Post (GC Corporation), DT Light Post Illusion (RTD), DT Light SL Post (RTD), Endo-Composipost (RTD), FibreKleer Parallel Post (Jeneric Pentron Incorporated), FRC Postec (Ivoclar Vivadent), Parapost Taper Lux (Còltene/Whaledent AG), Radix Fiber Post (Dentsply Maillefer), EverStick Post (Stick Tech Ltd), Dentin Post X (Komet), Tech 21 X-op (Isasan), ENA Post (Micerium). Post radiopacity was measured in millimetres of aluminium (mmAl) with reference to an aluminium step wedge. Two extracted contralateral premolars were root filled. After post space preparation, taking the midpoint of the post hole as a reference, each tooth was cut longitudinally into two halves in a mesiodistal direction. On each half, the exposed root dentine was ground flat to the deepest point of the post space, and an even layer of cement was placed and light-cured. To obtain a clinically relevant layer of cement, the material thickness was reduced to 75 μm by grinding with wet abrasive paper. A cement formulation with 30 wt% of filler was tested in one premolar, whilst a formulation with 70 wt% of filler was utilized in the contralateral tooth. Posts were then placed between the two facing root halves of each premolar, and radiopacity was measured in mmAl. Data were analysed using t-test for paired samples (P < 0.05). RESULTS Radiopacity of posts ranged between 1.44 (ENA Post) and 5.78 mmAl (FibreKleer). In the presence of the more heavily filled cement, significantly higher values of post radiopacity were measured (P < 0.001). CONCLUSION The radiopacity of the luting agent contributed to the overall post radiovisibility within the root. Even when the cement with lower filler content was used in combination with the least radiodense dowels, the post was detectable within the root.
Collapse
|
41
|
Flexural resistance of Cerec CAD/CAM system ceramic blocks. Part 2: Outsourcing materials. AMERICAN JOURNAL OF DENTISTRY 2014; 27:17-22. [PMID: 24902400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
PURPOSE To test different Cerec CAD/CAM system ceramic blocks, comparing mean flexural strength (sigma), Weibull modulus (m), and Weibull characteristic strength (sigma0) in an ISO standardized set-up. METHODS Following the recent ISO Standard (ISO 6872:2008), 11 types of ceramic blocks were tested: IPS e.max CAD MO, IPS e.max CAD LT and IPS e.max CAD HT (lithium disilicate glass-ceramic); In-Ceram SPINELL, In-Ceram Alumina and In-Ceram Zirconia (glass-infiltrated materials); inCoris AL and In-Ceram AL (densely sintered alumina); In-Ceram YZ, IPS e.max Zir-CAD and inCoris ZI (densely sintered zirconia). Specimens were cut out from ceramic blocks, finished, crystallized/infiltrated/sintered, polished, and tested in a three-point bending test apparatus. Flexural strength, Weibull characteristic strength, and Weibull modulus were obtained. RESULTS A statistically significant difference was found (P < 0.001) among lithium disilicate glass-ceramic (sigma = 272.6 +/- 376.8 MPa, m = 6.2 +/- 11.3, sigma0 = 294.0 +/- 394.1 MPa) and densely sintered alumina (sigma = 441.8 +/- 541.6 MPa, m = 11.9 +/- 19.0, sigma0 = 454.2 +/- 565.2 MPa). No statistically significant difference was found (P = 0.254) in glass infiltrated materials (sigma = 376.9 +/- 405.5 MPa, m = 7.5 +/- 11.5, sigma0 = 393.7 +/- 427.0 MPa). No statistically significant difference was found (P = 0.160) in densely sintered zirconia (sigma = 1,060.8 +/- 1,227.8 MPa, m = 5.8 +/- 7.4, sigma0 = 1,002.4 +/- 1,171.0 MPa). Not all the materials tested fulfilled the requirements for the clinical indications recommended by the manufacturer.
Collapse
|
42
|
|
43
|
Roughness of lithium-silicate and lithium-disilicate ceramics after HF etching. Dent Mater 2014. [DOI: 10.1016/j.dental.2014.08.064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
44
|
Post-retentive ability of new flowable resin composites. AMERICAN JOURNAL OF DENTISTRY 2013; 26:324-328. [PMID: 24640436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
PURPOSE To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts. METHODS 36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05). RESULTS The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 +/- 2.17 MPa) performed similarly to the control group NX3 (7.15 +/- 1.74 MPa), while VF (4.81 +/- 1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.
Collapse
|
45
|
Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites. AMERICAN JOURNAL OF DENTISTRY 2013; 26:271-277. [PMID: 24479279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
PURPOSE To evaluate the microleakage of Class II cavities restored with experimental low-shrinking resin composites proposed for bulk filling and to measure their microtensile bond strength (microTBS) to dentin and compare to those of previously marketed low-shrinkage composites. METHODS Class II cavities (7 mm occluso-gingival height, 2 mm mesio-distal depth of the box, 4 mm occlusal depth, 4 mm bucco-lingual width) were prepared in 50 molars and randomly divided into five groups (n = 10), according to the material: SureFil SDR flow (SDR), Filtek Silorane (FS) and experimental materials (G-aenial Flo bulk fill, GF; G-aenial Universal Flo bulk fill, GUF; GC Kalore bulk fill, GK). Microleakage was separately assessed at enamel and dentin margins by scoring the depth of silver-nitrate penetration. Twenty teeth divided into five groups (n = 4) were selected for microTBS testing. The same materials as for microleakage assessment were placed in bulk to mid-coronal dentin. Microtensile beams were loaded in tension, and microTBS at failure was calculated in MPa. Microleakage and microTBS data were analyzed by ANOVA on ranks, followed Dunn's post hoc test (P< 0.05). RESULTS Microleakage was not observed at the enamel interface in any of the groups. At the dentin interface, SDR recorded significantly higher microleakage than the other materials. microTBS of GF, GUF and GK did not differ among each other (33 +/- 12 MPa, 31 +/- 11 MPa, 30 +/- 9 MPa, respectively), while SDR (63 +/- 17 MPa) and FS (55 +/- 17MPa) achieved significantly higher microTBS values. No direct association between the sealing properties and the bond strength values was observed.
Collapse
|
46
|
Flexural resistance of Cerec CAD/CAM system ceramic blocks. Part 1: Chairside materials. AMERICAN JOURNAL OF DENTISTRY 2013; 26:255-259. [PMID: 24479276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
PURPOSE This study tested the materials available on the market for Cerec CAD/CAM, comparing the mean flexural strength in an ISO standardized set-up, since the ISO standard for testing such materials was issued later than the marketing of the materials tested. METHODS Following the recent Standard ISO 6872:2008, eight types of ceramic blocks were tested: Paradigm C, IPS Empress CAD LT, IPS Empress CAD Multi, Cerec Blocs, Cerec Blocs PC, Triluxe, Triluxe Forte, Mark II. Specimens were cut out from ceramic blocks, finished, polished, and tested in a three-point bending test apparatus until failure. Flexural strength, Weibull characteristic strength, and Weibull modulus, were calculated. RESULTS The results obtained from the materials for flexural strength were IPS Empress CAD (125.10 +/- 13.05), Cerec Blocs (112.68 +/- 7.97), Paradigm C (109.14 +/- 10.10), Cerec Blocs PC (105.40 +/- 5.39), Triluxe Forte (105.06 +/- 4.93), Mark II (102.77 +/- 3.60), Triluxe (101.95 +/- 7.28) and IPS Empress CAD Multi (100.86 +/- 15.82). All the tested materials had a flexural strength greater than 100 MPa, thereby satisfying the requirements of the ISO standard for the clinical indications of the materials tested. In all tested materials the Weibull characteristic strength was greater than 100 MPa.
Collapse
|
47
|
Influence of selective enamel etching on the bonding effectiveness of a new "all-in-one" adhesive. AMERICAN JOURNAL OF DENTISTRY 2013; 26:99-104. [PMID: 24073533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
PURPOSE To evaluate in vitro the all-in-one adhesive G-Bond Plus/G-aenial Bond (GBP), used according to the selective enamel etching (SEE) technique, compared to Optibond FL, an etch-and-rinse adhesive tested as control (C). METHODS 133 molars provided specimens for enamel and dentin shear bond strength (SBS) testing, microleakage measurements in class 5 restorations, and scanning electron microscope observations of demineralization patterns produced by GBP and 37% phosphoric acid (PA). RESULTS On enamel: C displayed the highest SBS. PA etching significantly increased enamel SBS of GBP. No statistically significant difference in SBS was noted among the bonding procedures on dentin. On both substrates, C revealed the most satisfactory seal. PA pre-etching did not significantly affect the sealing ability of GBP on either substrate.
Collapse
|
48
|
Shear bond strength to enamel and flexural strength of different fiber-reinforced composites. THE JOURNAL OF ADHESIVE DENTISTRY 2013; 15:123-30. [PMID: 23534006 DOI: 10.3290/j.jad.a28362] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To assess the shear bond strength to unground human enamel (ESBS) and flexural strength (FS) of different reinforcing fibers used in combination with a flowable composite resin. MATERIALS AND METHODS For ESBS testing, 90 human molars were selected and randomly divided into 9 groups (n = 10) according to the reinforcing fiber to be tested: 1. RTD Quartz Splint additionally impregnated at chairside with Quartz Splint Resin (RTD); 2. RTD Quartz Splint without additional impregnation; 3. Ribbond-THM (Ribbond) impregnated with OptiBond FL Adhesive; 4: Ribbond Triaxial (Ribbond) impregnated with OptiBond FL Adhesive; 5. Connect (Kerr) impregnated with OptiBond FL Adhesive; 6. Construct (Kerr) impregnated with Opti- Bond FL Adhesive; 7. everStick PERIO (Stick Tech); 8. everStick C&B (Stick Tech); 9. nonreinforced composite Premise flowable (Kerr). Cylinders of flowable composite reinforced with the fibers were bonded to the intact buccal surface of the teeth. After 24 h of storage, shear loading was performed until failure occurred. FS was assessed performing three-point bending test according to ISO Standard 4049/2000. ESBS and FS data were analyzed using one-way ANOVA, followed by Tukey's HSD test for post-hoc comparisons (p < 0.05). RESULTS For each group, the ESBS and FS, respectively, in MPa were: 1. 17.07 ± 4.52 and 472.69 ± 30.49; 2. 14.98 ± 3.92 and 441.77 ± 61.43; 3. 18.59 ± 5.67 and 186.89 ± 43.89; 4. 16.74 ± 6.27 and 314.41 ± 148.52; 5. 14.38 ± 4.14 and 223.80 ± 77.35; 6. 16.00 ± 5.55 and 287.62 ± 85.91; 7. 16.42 ± 3.67 and 285.35 ± 39.68; 8. 23.24 ± 5.81 and 370.46 ± 29.26; 9. 12.58 ± 4.76 and 87.75 ± 22.87. For most fibers, no significant difference in ESBS was found compared to the control group, except for everStick C&B, which yielded higher ESBS. Nonreinforced composite exhibited the lowest FS, while all fibers positively affected the FS. CONCLUSIONS Fiber reinforcement of flowable composite does not affect its ESBS. The flexural strength of FRCs is significantly influenced by fiber composition and pattern.
Collapse
|
49
|
Spectrophotometric evaluation of color match of three different porcelain systems for all-ceramic zirconia-based restorations. AMERICAN JOURNAL OF DENTISTRY 2012; 25:191-194. [PMID: 23082380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
PURPOSE To determine by a spectrophotometric analysis the variations in color between the intended and the fabricated shades of three different porcelain systems when applied in a standardized thickness on a zirconia core. METHODS Three porcelain systems for zirconia based restorations, Ivoclar IPS e.max Ceram, VITA VM9, and Creation Zi-F were tested. Nine disc-shaped (15 mm diameter, 0.5 mm thickness) specimens of VITA YZ zirconia core per group were made comprising a total of 27 discs. Three different shades (A2, A3, A4) of the Vitapan Classical shade guide were investigated. The porcelain veneer total thickness was set at 1.0 mm in all groups. The porcelain stratification was made by applying calibrated layers of porcelain. Thicknesses of single porcelain layers were calculated from drawings retrieved from the manufacturers' instructions. Color parameters (L*, a*, b*) of veneered specimens were measured by a clinical spectrophotometer. Color differences (deltaE) were calculated using a color difference formula. Two-way ANOVA and Tukey's test were used to analyze the data. RESULTS The mean color differences for the three ceramic systems, Ivoclar IPS e.max Ceram, VITA VM9 and Creation Zi-F were respectively 4.1, 2.7 and 3.2, regardless of the shades. VITA VM9 resulted in the best average shade matching among the porcelain systems, even if results with shade A3 were considerably worse than shades with A2 and A4 (P<0.05). Color matching appeared not to be shade dependent (P>0.05) among the tested shades.
Collapse
|
50
|
Enamel and dentin bond strength of new simplified adhesive materials with and without preliminary phosphoric acid-etching. AMERICAN JOURNAL OF DENTISTRY 2012; 25:239-243. [PMID: 23082390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
PURPOSE To assess the influence of preliminary phosphoric acid-etching on shear bond strength (SBS) to enamel and dentin of a self-adhering restorative composite and of a new self-etch adhesive used in combination with the proprietary flowable composite. METHODS 100 human molars were selected. SBS was assessed on flat buccal enamel surfaces and mid-coronal dentin. Teeth from each group were divided into five subgroups (n=10): (1) FL: etch-and-rinse adhesive OptiBond FL/Premise flowable; (2) XTR: 2-step self-etch adhesive OptiBond XTR/Premise flowable; (3) eXTR: OptiBond XTR on etched substrates/Premise flowable; (4) VF: self-adhering flowable composite Vertise Flow; (5) eVF: Vertise Flow on etched substrates. Specimens were stressed in shear until failure. Failure modes were evaluated under a stereomicroscope. Data were analyzed by two-way ANOVA and Fisher's exact test (P< 0.05). RESULTS Dental substrate, material and between-factor interaction significantly influenced SBS (MPa). In FL group (16.83 +/- 2.93) significantly higher SBS to enamel than in the other groups (XTR 8.59 +/- 4.39; eXTR 7.04 +/- 3.63; VF 6.61 +/- 2,41; eVF 9.87 +/- 4.24) was measured. On dentin FL (8.15 +/- 3.88) performed similarly to XTR (10.60 +/- 5.0), eXTR (9.60 +/- 4.91) and eVF (5.48 +/- 4.94); VF recorded significantly lower SBS (2.94 +/- 2.79 MPa). Failure modes differed significantly among groups.
Collapse
|