1
|
Beyond life: Exploring hemodynamic patterns in postmortem mice brains. JOURNAL OF BIOPHOTONICS 2024:e202400017. [PMID: 38714530 DOI: 10.1002/jbio.202400017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/14/2024] [Accepted: 04/09/2024] [Indexed: 05/10/2024]
Abstract
We utilize Laser Speckle Contrast Imaging (LSCI) for visualizing cerebral blood flow in mice during and post-cardiac arrest. Analyzing LSCI images, we noted temporal blood flow variations across the brain surface for hours postmortem. Fast Fourier Transform (FFT) analysis depicted blood flow and microcirculation decay post-death. Continuous Wavelet Transform (CWT) identified potential cerebral hemodynamic synchronization patterns. Additionally, non-negative matrix factorization (NMF) with four components segmented LSCI images, revealing structural subcomponent alterations over time. This integrated approach of LSCI, FFT, CWT, and NMF offers a comprehensive tool for studying cerebral blood flow dynamics, metaphorically capturing the 'end of the tunnel' experience. Results showed primary postmortem hemodynamic activity in the olfactory bulbs, followed by blood microflow relocations between somatosensory and visual cortical regions via the superior sagittal sinus. This method opens new avenues for exploring these phenomena, potentially linking neuroscientific insights with mysteries surrounding consciousness and perception at life's end.
Collapse
|
2
|
Incremental residual polarization caused by aging in human skin. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:052912. [PMID: 38077500 PMCID: PMC10704186 DOI: 10.1117/1.jbo.29.5.052912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 09/01/2023] [Accepted: 10/19/2023] [Indexed: 12/18/2023]
Abstract
Significance The study of the effect of aging on the optical properties of biological tissues, in particular polarization, is important in the development of new diagnostic approaches. Aim This work aims to provide a comprehensive analysis of the factors and mechanisms that contribute to the alteration of skin polarization properties caused by aging, using polarization-sensitive hyperspectral imaging measurements and Monte Carlo simulation. Approach Our investigation involved both experimental studies of in vivo human skin of volunteers of different ages and computational modeling that accounted for changes in the absorption and scattering properties of the skin model. Specifically, we analyzed alterations in the degree of linear polarization (DOLP) to better understand the impact of aging on skin polarization properties. Results A statistically significant increase in the DOLP was found for the elderly group. At the same time, there was no correlation between changes in polarization and the calculated blood volume fraction parameter for different ages. According to the simulation results, it was also found that a change in the scattering properties of biological tissues has a more significant effect on the change in polarizing light compared to the change in absorption. Conclusions The results of the work prove that the sensitivity of polarization imaging to age- or pathological-related skin changes may be primarily due to changes in scattering, which in turn is associated with changes in the collagen fibers of the dermis. The proposed technique shows promise for in vivo non-invasive real-time assessment of age-associated skin changes and can also be extended to monitor changes associated with the development of age-related pathologies.
Collapse
|
3
|
Exploring the evolution of circular polarized light backscattered from turbid tissue-like disperse medium utilizing generalized Monte Carlo modeling approach with a combined use of Jones and Stokes-Mueller formalisms. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:052913. [PMID: 38089555 PMCID: PMC10715447 DOI: 10.1117/1.jbo.29.5.052913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 10/24/2023] [Accepted: 10/26/2023] [Indexed: 12/18/2023]
Abstract
Significance Phase retardation of circularly polarized light (CPL), backscattered by biological tissue, is used extensively for quantitative evaluation of cervical intraepithelial neoplasia, presence of senile Alzheimer's plaques, and characterization of biotissues with optical anisotropy. The Stokes polarimetry and Mueller matrix approaches demonstrate high potential in definitive non-invasive cancer diagnosis and tissue characterization. The ultimate understanding of CPL interaction with tissues is essential for advancing medical diagnostics, optical imaging, therapeutic applications, and the development of optical instruments and devices. Aim We investigate propagation of CPL within turbid tissue-like scattering medium utilizing a combination of Jones and Stokes-Mueller formalisms in a Monte Carlo (MC) modeling approach. We explore the fundamentals of CPL memory effect and depolarization formation. Approach The generalized MC computational approach developed for polarization tracking within turbid tissue-like scattering medium is based on the iterative solution of the Bethe-Salpeter equation. The approach handles helicity response of CPL scattered in turbid medium and provides explicit expressions for assessment of its polarization state. Results Evolution of CPL backscattered by tissue-like medium at different conditions of observation in terms of source-detector configuration is assessed quantitatively. The depolarization of light is presented in terms of the coherence matrix and Stokes-Mueller formalism. The obtained results reveal the origins of the helicity flip of CPL depending on the source-detector configuration and the properties of the medium and are in a good agreement with the experiment. Conclusions By integrating Jones and Stokes-Mueller formalisms, the combined MC approach allows for a more complete representation of polarization effects in complex optical systems. The developed model is suitable to imitate propagation of the light beams of different shape and profile, including Gaussian, Bessel, Hermite-Gaussian, and Laguerre-Gaussian beams, within tissue-like medium. Diverse configuration of the experimental conditions, coherent properties of light, and peculiarities of polarization can be also taken into account.
Collapse
|
4
|
Mueller-matrix imaging polarimetry elevated by wavelet decomposition and polarization-singular processing for analysis of specific cancerous tissue pathology. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:102903. [PMID: 37425430 PMCID: PMC10329407 DOI: 10.1117/1.jbo.28.10.102903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 06/12/2023] [Accepted: 06/14/2023] [Indexed: 07/11/2023]
Abstract
Significance Mueller-matrix polarimetry is a powerful method allowing for the visualization of malformations in biological tissues and quantitative evaluation of alterations associated with the progression of various diseases. This approach, in fact, is limited in observation of spatial localization and scale-selective changes in the poly-crystalline compound of tissue samples. Aim We aimed to improve the Mueller-matrix polarimetry approach by implementing the wavelet decomposition accompanied with the polarization-singular processing for express differential diagnosis of local changes in the poly-crystalline structure of tissue samples with various pathology. Approach Mueller-matrix maps obtained experimentally in transmitted mode are processed utilizing a combination of a topological singular polarization approach and scale-selective wavelet analysis for quantitative assessment of the adenoma and carcinoma histological sections of the prostate tissues. Results A relationship between the characteristic values of the Mueller-matrix elements and singular states of linear and circular polarization is established within the framework of the phase anisotropy phenomenological model in terms of linear birefringence. A robust method for expedited (up to ∼15 min) polarimetric-based differential diagnosis of local variations in the poly-crystalline structure of tissue samples containing various pathology abnormalities is introduced. Conclusions The benign and malignant states of the prostate tissue are identified and assessed quantitatively with a superior accuracy provided by the developed Mueller-matrix polarimetry approach.
Collapse
|
5
|
Impact of Plasmonic Nanoparticles on Poikilocytosis and Microrheological Properties of Erythrocytes. Pharmaceutics 2023; 15:pharmaceutics15041046. [PMID: 37111532 PMCID: PMC10143243 DOI: 10.3390/pharmaceutics15041046] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/03/2023] [Accepted: 03/17/2023] [Indexed: 04/29/2023] Open
Abstract
Plasmonic nanoparticles (NP) possess great potential in photothermal therapy and diagnostics. However, novel NP require a detailed examination for potential toxicity and peculiarities of interaction with cells. Red blood cells (RBC) are important for NP distribution and the development of hybrid RBC-NP delivery systems. This research explored RBC alterations induced by noble (Au and Ag) and nitride-based (TiN and ZrN) laser-synthesized plasmonic NP. Optical tweezers and conventional microscopy modalities indicated the effects arising at non-hemolytic levels, such as RBC poikilocytosis, and alterations in RBC microrheological parameters, elasticity and intercellular interactions. Aggregation and deformability significantly decreased for echinocytes independently of NP type, while for intact RBC, all NP except Ag NP increased the interaction forces but had no effect on RBC deformability. RBC poikilocytosis promoted by NP at concentration 50 μg mL-1 was more pronounced for Au and Ag NP, compared to TiN and ZrN NP. Nitride-based NP demonstrated better biocompatibility towards RBC and higher photothermal efficiency than their noble metal counterparts.
Collapse
|
6
|
Terahertz-to-infrared converters for imaging the human skin cancer: challenges and feasibility. J Med Imaging (Bellingham) 2023; 10:023501. [PMID: 36925632 PMCID: PMC10012600 DOI: 10.1117/1.jmi.10.2.023501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Accepted: 02/06/2023] [Indexed: 03/16/2023] Open
Abstract
Purpose Terahertz (THz) medical imaging is a promising noninvasive technique for monitoring the skin's conditions, early detection of the human skin cancer, and recovery from burns and wounds. It can be applied for visualization of the healing process directly through clinical dressings and restorative ointments, minimizing the frequency of dressing changes. The THz imaging technique is cost effective, as compared to the magnetic resonance method. Our aim was to develop an approach capable of providing better image resolution than the commercially available THz imaging cameras. Approach The terahertz-to-infrared (THz-to-IR) converters can visualize the human skin cancer by converting the latter's specific contrast patterns recognizable in THz radiation range into IR patterns, detectable by a standard IR imaging camera. At the core of suggested THz-to-IR converters are flat matrices transparent both in the THz range to be visualized and in the operating range of the IR camera, these matrices contain embedded metal nanoparticles (NPs), which, when irradiated with THz rays, convert the energy of THz photons into heat and become nanosources of IR radiation detectable by an IR camera. Results The ways of creating the simplest converter, as well as a more complex converter with wider capabilities, are considered. The first converter is a gelatin matrix with gold 8.5-nm diameter NPs, and the second is a polystyrene matrix with 2-nm diameter NPs from copper-nickel MONEL® alloy 404. Conclusions An approach with a THz-to-IR converter equipped with an IR camera is promising in that it could provide a better image of oncological pathology than the commercially available THz imaging cameras do.
Collapse
|
7
|
Brillouin Interaction between Two Optical Modes Selectively Excited in Weakly Guiding Multimode Optical Fibers. SENSORS (BASEL, SWITZERLAND) 2023; 23:1715. [PMID: 36772756 PMCID: PMC9919090 DOI: 10.3390/s23031715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 01/29/2023] [Accepted: 01/31/2023] [Indexed: 06/18/2023]
Abstract
A multimode optical fiber supports excitation and propagation of a pure single optical mode, i.e., the field pattern that satisfies the boundary conditions and does not change along the fiber. When two counterpropagating pure optical modes are excited, they could interact through the stimulated Brillouin scattering (SBS) process. Here, we present a simple theoretical formalism describing SBS interaction between two individual optical modes selectively excited in an acoustically isotropic multimode optical fiber. Employing a weakly guiding step-index fiber approach, we have built an analytical expression for the spatial distribution of the sound field amplitude in the fiber core and explored the features of SBS gain spectra, describing the interaction between modes of different orders. In this way, we give a clear insight into the sound propagation effects accompanying SBS in multimode optical fibers, and demonstrate their specific contributions to the SBS gain spectrum.
Collapse
|
8
|
Diagnosis of Skin Vascular Complications Revealed by Time-Frequency Analysis and Laser Doppler Spectrum Decomposition. IEEE Trans Biomed Eng 2023; 70:3-14. [PMID: 35679373 DOI: 10.1109/tbme.2022.3181126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Nowadays, photonics-based techniques are used extensively in various applications, including functional clinical diagnosis, progress monitoring in treatment, and provision of metrological control. In fact, in the frame of practical implementation of optical methods, such as laser Doppler flowmetry (LDF), the qualitative interpretation and quantitative assessment of the detected signal remains vital and urgently required. In the conventional LDF approach, the key measured parameters, index of microcirculation and perfusion rate, are proportional to an averaged concentration of red blood cells (RBC) and their average velocity within a diagnostic volume. These quantities compose mixed signals from different vascular beds with a range of blood flow velocities and are typically expressed in relative units. In the current paper we introduce a new signal processing approach for the decomposition of LDF power spectra in terms of ranging blood flow distribution by frequency series. The developed approach was validated in standard occlusion tests conducted on healthy volunteers, and applied to investigate the influence of local pressure rendered by a probe on the surface of the skin. Finally, in limited clinical trials, we demonstrate that the approach can significantly improve the diagnostic accuracy of detection of microvascular changes in the skin of the feet in patients with Diabetes Mellitus type 2, as well as age-specific changes. The results obtained show that the developed approach of LDF signal decomposition provides essential new information about blood flow and blood microcirculation and has great potential in the diagnosis of vascular complications associated with various diseases.
Collapse
|
9
|
Optical anisotropy composition of benign and malignant prostate tissues revealed by Mueller-matrix imaging. BIOMEDICAL OPTICS EXPRESS 2022; 13:6019-6034. [PMID: 36733722 PMCID: PMC9872883 DOI: 10.1364/boe.464420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 09/07/2022] [Accepted: 09/18/2022] [Indexed: 06/18/2023]
Abstract
A Mueller matrix imaging approach is employed to disclose the three-dimensional composition framework of optical anisotropy within cancerous biotissues. Visualized by the Mueller matrix technique spatial architecture of optical anisotropy of tissues is characterised by high-order statistical moments. Thus, quantitative analysis of the spatial distribution of optical anisotropy, such as linear and circular birefringence and dichroism, is revealed by using high-order statistical moments, enabling definitively discriminate prostate adenoma and carcinoma. The developed approach provides greater (>90%) accuracy of diagnostic achieved by using either the 3-rd or 4-th order statistical moments of the linear anisotropy parameters. Noticeable difference is observed between prostate adenoma and carcinoma tissue samples in terms of the extinction coefficient and the degree of depolarisation. Juxtaposition to other optical diagnostic modalities demonstrates the greater accuracy of the approach described herein, paving the way for its wider application in cancer diagnosis and tissue characterization.
Collapse
|
10
|
Abstract
In optogenetics, as in nature, sensory photoreceptors serve to control cellular processes by light. Bacteriophytochrome (BphP) photoreceptors sense red and far-red light via a biliverdin chromophore and, in response, cycle between the spectroscopically, structurally, and functionally distinct Pr and Pfr states. BphPs commonly belong to two-component systems that control the phosphorylation of cognate response regulators and downstream gene expression through histidine kinase modules. We recently demonstrated that the paradigm BphP from Deinococcus radiodurans exclusively acts as a phosphatase but that its photosensory module can control the histidine kinase activity of homologous receptors. Here, we apply this insight to reprogram two widely used setups for bacterial gene expression from blue-light to red-light control. The resultant pREDusk and pREDawn systems allow gene expression to be regulated down and up, respectively, uniformly under red light by 100-fold or more. Both setups are realized as portable, single plasmids that encode all necessary components including the biliverdin-producing machinery. The triggering by red light affords high spatial resolution down to the single-cell level. As pREDusk and pREDawn respond sensitively to red light, they support multiplexing with optogenetic systems sensitive to other light colors. Owing to the superior tissue penetration of red light, the pREDawn system can be triggered at therapeutically safe light intensities through material layers, replicating the optical properties of the skin and skull. Given these advantages, pREDusk and pREDawn enable red-light-regulated expression for diverse use cases in bacteria.
Collapse
|
11
|
Multiplexed spatially-focused localization of light in adipose biological tissues. Sci Rep 2022; 12:9711. [PMID: 35690671 PMCID: PMC9188595 DOI: 10.1038/s41598-022-14350-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 06/06/2022] [Indexed: 11/22/2022] Open
Abstract
Last decades the effects of localization and focusing of light in turbid randomly inhomogeneous tissue-like scattering medium have been attracting a particular attention. Weak localization of light in disordered and weakly ordered biological tissue, polarization memory effect, correlations in transmission matrices, focusing light by wavefronts shaping have been widely exploited. Here, we represent an experimentally observed and theoretically confirmed new type of spatial localization of light within biological tissues. General description of the observed phenomenon based on Monte Carlo ray tracing model is provided. We find that innate body arrangements of individual adipocytes can act as a cascade of quasi-ordered microscale lenses confining propagation of light within adipose tissues similar to lens lightguides. The observed spatially-resolved longitudinal multi-focusing of light within disordered adipose biological tissues can naturally lead greater spatial control and enhance light-tissue interactions.
Collapse
|
12
|
Hemorheological alterations of red blood cells induced by 450-nm and 520-nm laser radiation. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2022; 230:112438. [PMID: 35405617 DOI: 10.1016/j.jphotobiol.2022.112438] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 03/21/2022] [Accepted: 03/25/2022] [Indexed: 06/14/2023]
Abstract
Proper rheological properties of red blood cells (RBC) including flexibility and aggregability are essential for healthy blood microcirculation. Excessive RBC aggregation has been observed to be associated with many pathological conditions and is crucial in acute circulatory problems. Low-level laser radiation (LLLR) has been found to have positive effects on the rheology of human blood, however, the detailed mechanisms of blood photobiomodulation remains unclear. In this study, utilizing the single-cell technique optical tweezers (OT) and traditional light microscopy, the influence of photobiomodulation of human RBC was examined under different conditions of laser irradiation. The results revealed that high radiant exposure (over 170.5 J/cm2 radiant fluence) caused enhanced RBC aggregation and cell shape transformation while the aggregation force between single RBC remained unchanged. LLLR with radiant fluence below 9.5 J/cm2 by 450 nm wavelength improved the RBC deformability, weakened the strength of cell-cell interaction in the RBC disaggregation process, and showed rejuvenating effects on RBC suspended in a harsh cell environment.
Collapse
|
13
|
Screening of Alzheimer's Disease With Multiwavelength Stokes Polarimetry in a Mouse Model. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:977-982. [PMID: 34807820 DOI: 10.1109/tmi.2021.3129700] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The minimum histological criterion for the diagnostics of Alzheimer's disease (AD) in tissue is the presence of senile plaques and neurofibrillary tangles in specific brain locations. The routine procedure of morphological analysis implies time-consuming and laborious steps including sectioning and staining of formalin-fixed paraffin-embedded (FFPE) tissue. We developed a multispectral Stokes polarimetric imaging approach that allows characterization of FFPE brain tissue samples to discern the stages of AD progression without sectioning and staining the tissue. The Stokes polarimetry approach is highly sensitive to structural alterations of brain tissue, particularly to the changes in light scattering and birefringence. We present the results of the label-free non-destructive screening of FFPE mouse brain tissue and show several polarization metrics that demonstrate statistically significant differences for tissues at different stages of AD.
Collapse
|
14
|
A review of career devoted to Biophotonics – In memoriam to Ekaterina Borisova (1978–2021). JOURNAL OF BIOMEDICAL PHOTONICS & ENGINEERING 2021; 7:040101. [DOI: 10.18287/jbpe21.07.040101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
|
15
|
Impairments of cerebral blood flow microcirculation in rats brought on by cardiac cessation and respiratory arrest. JOURNAL OF BIOPHOTONICS 2021; 14:e202100216. [PMID: 34534405 DOI: 10.1002/jbio.202100216] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/06/2021] [Accepted: 09/09/2021] [Indexed: 05/21/2023]
Abstract
The impairments of cerebral blood flow microcirculation brought on by cardiac and respiratory arrest were assessed with multi-modal diagnostic facilities, utilising laser speckle contrast imaging, fluorescence spectroscopy and diffuse reflectance spectroscopy. The results of laser speckle contrast imaging show a notable reduction of cerebral blood flow in small and medium size vessels during a few minutes of respiratory arrest, while the same effect was observed in large sinuses and their branches during the circulatory cessation. Concurrently, the redox ratio assessed with fluorescence spectroscopy indicates progressing hypoxia, NADH accumulation and increase of FAD consumption. The results of diffuse reflectance spectra measurements display a more rapid grow of the perfusion of deoxygenated blood in case of circulatory impairment. In addition, consequent histopathological analysis performed by using new tissue staining procedure developed in-house. It shows notably higher reduction of size of the neurons due to their wrinkling within brain tissues influenced by circulation impair. Whereas, the brain tissues altered with the respiratory arrest demonstrate focal perivascular oedema and mild hypoxic changes of neuronal morphology. Thus, the study suggests that consequences of a cessation of cerebral blood flow become more dramatic and dangerous compare to respiratory arrest.
Collapse
|
16
|
Polarization and depolarization metrics as optical markers in support to histopathology of ex vivo colon tissue. BIOMEDICAL OPTICS EXPRESS 2021; 12:4560-4572. [PMID: 34457432 PMCID: PMC8367259 DOI: 10.1364/boe.426713] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 05/27/2021] [Accepted: 05/29/2021] [Indexed: 05/08/2023]
Abstract
Tissue polarimetry holds great promise to improve the effectiveness of conventional cancer diagnostics and staging, being a fast, minimally invasive, and low-cost optical technique. We introduce an enhanced diagnostic method for ex vivo colon specimens assessment by utilizing Stokes and Mueller matrix polarimetry. The proposed method makes use of experimental Mueller matrices, measured from healthy and tumor zones of a colon specimen, as input data for post-processing algorithms that include physical realisability filtering, symmetric decomposition and estimation of various polarization and depolarization metrics for colon specimen diagnostics. We validated our results with the gold standard histological diagnostics provided by pathologists. It was found that the Stokes-Mueller matrix polarimetry, combined with the appropriate filtering, decomposition algorithms and polarization/depolarization metrics calculations provides relevant optical markers of the colon tissue pathological conditions (healthy versus cancer), as confirmed by histopathology analysis. This approach potentially provides physicians with valuable and complementary information that holds promises in helping with the diagnostics of colon tissue specimens.
Collapse
|
17
|
Evolution of raw meat polarization-based properties by means of Mueller matrix imaging. JOURNAL OF BIOPHOTONICS 2021; 14:e202000376. [PMID: 33220020 DOI: 10.1002/jbio.202000376] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 11/03/2020] [Accepted: 11/18/2020] [Indexed: 05/06/2023]
Abstract
The possibilities of using Mueller matrix (MM) imaging polarimetry to assess meat quality have not yet been sufficiently explored. In the current study, the fresh porcine muscles are imaged at room temperature with a wide-field MM imaging polarimeter over 26 hours to visualize dynamics of tissue optical properties through applying Lu-Chipman decomposition. The frequency distribution histograms (FDHs) and statistical analysis of the MM elements show prominent changes over time. The wavelength spectra of both total depolarization and scalar retardance have dips at 550 nm whereas their values continuously increase with time; the former is referred to the increase of number of scattering events and decrease of myoglobin absorption in the red part of visible spectra related to meat color and freshness, while the latter is associated with the increase in birefringence and meat tenderness. The obtained results are promising to develop a novel fast noncontact optical technique for monitoring of meat quality.
Collapse
|
18
|
Skin Complications of Diabetes Mellitus Revealed by Polarized Hyperspectral Imaging and Machine Learning. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:1207-1216. [PMID: 33406038 DOI: 10.1109/tmi.2021.3049591] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Aging and diabetes lead to protein glycation and cause dysfunction of collagen-containing tissues. The accompanying structural and functional changes of collagen significantly contribute to the development of various pathological malformations affecting the skin, blood vessels, and nerves, causing a number of complications, increasing disability risks and threat to life. In fact, no methods of non-invasive assessment of glycation and associated metabolic processes in biotissues or prediction of possible skin complications, e.g., ulcers, currently exist for endocrinologists and clinical diagnosis. In this publication, utilizing emerging photonics-based technology, innovative solutions in machine learning, and definitive physiological characteristics, we introduce a diagnostic approach capable of evaluating the skin complications of diabetes mellitus at the very earlier stage. The results of the feasibility studies, as well as the actual tests on patients with diabetes and healthy volunteers, clearly show the ability of the approach to differentiate diabetic and control groups. Furthermore, the developed in-house polarization-based hyperspectral imaging technique accomplished with the implementation of the artificial neural network provides new horizons in the study and diagnosis of age-related diseases.
Collapse
|
19
|
3D Mueller matrix mapping of layered distributions of depolarisation degree for analysis of prostate adenoma and carcinoma diffuse tissues. Sci Rep 2021; 11:5162. [PMID: 33664274 PMCID: PMC7933337 DOI: 10.1038/s41598-021-83986-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 02/10/2021] [Indexed: 11/17/2022] Open
Abstract
Prostate cancer is the second most common cancer globally in men, and in some countries is now the most diagnosed form of cancer. It is necessary to differentiate between benign and malignant prostate conditions to give accurate diagnoses. We aim to demonstrate the use of a 3D Mueller matrix method to allow quick and easy clinical differentiation between prostate adenoma and carcinoma tissues with different grades and Gleason scores. Histological sections of benign and malignant prostate tumours, obtained by radical prostatectomy, were investigated. We map the degree of depolarisation in the different prostate tumour tissues using a Mueller matrix polarimeter set-up, based on the superposition of a reference laser beam with the interference pattern of the sample in the image plane. The depolarisation distributions can be directly related to the morphology of the biological tissues. The dependences of the magnitude of the 1st to 4th order statistical moments of the depolarisation distribution are determined, which characterise the distributions of the depolarisation values. To determine the diagnostic potential of the method three groups of histological sections of prostate tumour biopsies were formed. The first group contained 36 adenoma tissue samples, while the second contained 36 carcinoma tissue samples of a high grade (grade 4: poorly differentiated-4 + 4 Gleason score), and the third group contained 36 carcinoma tissue samples of a low grade (grade 1: moderately differentiated-3 + 3 Gleason score). Using the calculated values of the statistical moments, tumour tissues are categorised as either adenoma or carcinoma. A high level (> 90%) accuracy of differentiation between adenoma and carcinoma samples was achieved for each group. Differentiation between the high-grade and low-grade carcinoma samples was achieved with an accuracy of 87.5%. The results demonstrate that Mueller matrix mapping of the depolarisation distribution of prostate tumour tissues can accurately differentiate between adenoma and carcinoma, and between different grades of carcinoma. This represents a first step towards the implementation of 3D Mueller matrix mapping for clinical analysis and diagnosis of prostate tumours.
Collapse
|
20
|
In vivo nano-biosensing element of red blood cell-mediated delivery. Biosens Bioelectron 2020; 175:112845. [PMID: 33262059 DOI: 10.1016/j.bios.2020.112845] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 11/12/2020] [Accepted: 11/20/2020] [Indexed: 12/27/2022]
Abstract
Biosensors based on nanotechnology are developing rapidly and are widely applied in many fields including biomedicine, environmental monitoring, national defense and analytical chemistry, and have achieved vital positions in these fields. Novel nano-materials are intensively developed and manufactured for potential biosensing and theranostic applications while lacking comprehensive assessment of their potential health risks. The integration of diagnostic in vivo biosensors and the DDSs for delivery of therapeutic drugs holds an enormous potential in next-generation theranostic platforms. Controllable, precise, and safe delivery of diagnostic biosensing devices and therapeutic agents to the target tissues, organs, or cells is an important determinant in developing advanced nanobiosensor-based theranostic platforms. Particularly, inspired by the comprehensive biological investigations on the red blood cells (RBCs), advanced strategies of RBC-mediated in vivo delivery have been developed rapidly and are currently in different stages of transforming from research and design to pre-clinical and clinical investigations. In this review, the RBC-mediated delivery of in vivo nanobiosensors for applications of bio-imaging at the single-cell level, advanced medical diagnostics, and analytical detection of biomolecules and cellular activities are presented. A comprehensive perspective of the technical framework of the state-of-the-art RBC-mediated delivery systems is explained in detail to inspire the design and implementation of advanced nanobiosensor-based theranostic platforms taking advantage of RBC-delivery modalities.
Collapse
|
21
|
Evaluating β-amyloidosis progression in Alzheimer's disease with Mueller polarimetry. BIOMEDICAL OPTICS EXPRESS 2020; 11:4509-4519. [PMID: 32923060 PMCID: PMC7449745 DOI: 10.1364/boe.396294] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 07/01/2020] [Accepted: 07/06/2020] [Indexed: 05/02/2023]
Abstract
We applied the wide-field Mueller imaging polarimetry for the screening of formalin-fixed paraffin-embedded samples of mouse brain tissue at different stages of brain β-amyloidosis in Alzheimer's disease (AD). The accumulation of amyloid-beta (Aβ) deposits throughout the brain tissue is one of the key pathological hallmarks observed with the AD progression. We demonstrate that the presence of Aβ plaques influences the properties of backscattered polarized light, in particular, its degree of depolarization. By means of statistical analysis, we demonstrate that the high-order statistical moments of depolarization distributions, acquired with the multi-spectral Mueller imaging polarimetry, can be used as sensitive markers of the growing presence of Aβ plaques. The introduced label-free polarimetric approach has a potential to facilitate the current practice of the histopathology screening in terms of diagnosis accuracy, time and cost efficiency.
Collapse
|
22
|
Colon cancer detection by using Poincaré sphere and 2D polarimetric mapping of ex vivo colon samples. JOURNAL OF BIOPHOTONICS 2020; 13:e202000082. [PMID: 32390327 DOI: 10.1002/jbio.202000082] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/21/2020] [Accepted: 05/06/2020] [Indexed: 05/02/2023]
Abstract
This work is dedicated to the diagnosis and grading of colon cancer by a combined use of Poincaré sphere and 2D Stokes vector polarimetry mapping approaches. The major challenge consists in exploring the applicability of polarized light for noninvasive screening of the histological abnormalities within the samples of biological tissues. Experimental studies were conducted in ex vivo colon sample, excised after surgical procedure for colon tumor removal of G2-adenocarcinoma lesion. Polarimetric measurements in linear and circular regime were carried via personally developed polarimetric, optical set-up, using supercontinuous fiber laser with irradiation fixed at 635 nm. We apply the Poincaré sphere and two-dimensional Stokes vector scanning approach for screening the corresponding tissue samples. A comparison between linear and circular polarization states is made both for quantitative and qualitative evaluations. It is shown that circular polarization has better diagnostic capabilities than linear polarization, with higher dynamic ranges of the polarimetric parameters and better values of the diagnostic quantities. In addition to the standard polarimetry parameters, utilized as essential diagnostic markers, we apply statistical analysis to obtain more detailed information in frame of the applied diagnostic approach.
Collapse
|
23
|
A NON-ALCOHOLIC BEVERAGE FOR PREVENTION AND COMPREHENSIVE TREATMENT OF POST-TRAUMATIC OSTEOARTHRITIS IN PROFESSIONAL AND AMATEUR SPORT. HUMAN SPORT MEDICINE 2020. [DOI: 10.14529/hsm200214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Aim. The article aims to develop a non-alcoholic beverage for post-traumatic recovery of the structure and functions of cartilage tissue in professional and amateur athletes. Materials and methods. The materials used were a premix containing aquamin soluble (a natural source of calcium), glucosamine sulfate (a chondroprotector) and herbal components, as well as laboratory and industrial samples of a sports beverage. To assess the quality of the flavor syrup and the finished drink, generally accepted and special research methods were used including spectrophotometry, high performance liquid chromatography, and inverse voltammetry. Results. Beverage composition is scientifically substantiated based on the characteristics and functional properties of the ingredient composition. The main components of the formulation are premix 124-19, “Eleutherococcus” flavor and “Ginseng with herbs” flavor concentrated bases along with extracts of plant materials with synergistic properties for correcting metabolic processes in post-traumatic osteoarthritis. The novelty of the formulation is confirmed by the patent of the Russian Federation. There are evidence-based medical studies on the effectiveness and functional orientation of calcium and glucosamine in dietary supplements. A technology was developed for the extraction of plant materials, the innovativeness of which is the use of high pressure (100–200 MPA) for a short period of time (60–600 s). The formulation and technology of the beverage are tested in production conditions and are recommended for implementation. Conclusion. Sports beverages based on natural biological complexes can be effective for correcting metabolic disorders and maintaining health in post-traumatic osteoarthritis in professional and amateur sports.
Collapse
|
24
|
Role of scattering and birefringence in phase retardation revealed by locus of Stokes vector on Poincaré sphere. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-13. [PMID: 32436372 PMCID: PMC7238295 DOI: 10.1117/1.jbo.25.5.057001] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Accepted: 04/27/2020] [Indexed: 05/02/2023]
Abstract
SIGNIFICANCE Biological tissues are typically characterized by high anisotropic scattering and may also exhibit linear form birefringence. Both scattering and birefringence bias the phase shift between transverse electric field components of polarized light. These phase alterations are associated with particular structural malformations in the tissue. In fact, the majority of polarization-based techniques are unable to distinguish the nature of the phase shift induced by birefringence or scattering of light. AIM We explore the distinct contributions of scattering and birefringence in the phase retardation of circularly polarized light propagated in turbid tissue-like scattering medium. APPROACH The circularly polarized light in frame of Stokes polarimetry approach is used for the screening of biotissue phantoms and chicken skin samples. The change of optical properties in chicken skin is accomplished by optical clearing, which reduces scattering, and mechanical stretch, which induces birefringence. The change of optical properties of skin tissue is confirmed by spectrophotometric measurements and second-harmonic generation imaging. RESULTS The contributions of scattering and birefringence in the phase retardation of circularly polarized light propagated in biological tissues are distinguished by the locus of the Stokes vector mapped on the Poincaré sphere. The phase retardation of circularly polarized light due to scattering alterations is assessed. The value of birefringence in chicken skin is estimated as 0.3 × 10-3, which agrees with alternative studies. The change of birefringence of skin tissue due to mechanical stretch in the order of 10-6 is detected. CONCLUSIONS While the polarimetric parameters on their own do not allow distinguishing the contributions of scattering and birefringence, the resultant Stokes vector trajectory on the Poincaré sphere reveals the role of scattering and birefringence in the total phase retardation. The described approach, applied independently or in combination with Mueller polarimetry, can be beneficial for the advanced characterization of various types of malformations within biological tissues.
Collapse
|
25
|
Impact of Nanocapsules on Red Blood Cells Interplay Jointly Assessed by Optical Tweezers and Microscopy. MICROMACHINES 2019; 11:E19. [PMID: 31878030 PMCID: PMC7020003 DOI: 10.3390/mi11010019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2019] [Revised: 12/11/2019] [Accepted: 12/17/2019] [Indexed: 12/23/2022]
Abstract
In the framework of novel medical paradigm the red blood cells (RBCs) have a great potential to be used as drug delivery carriers. This approach requires an ultimate understanding of the peculiarities of mutual interaction of RBC influenced by nano-materials composed the drugs. Optical tweezers (OT) is widely used to explore mechanisms of cells' interaction with the ability to trap non-invasively, manipulate and displace living cells with a notably high accuracy. In the current study, the mutual interaction of RBC with polymeric nano-capsules (NCs) is investigated utilizing a two-channel OT system. The obtained results suggest that, in the presence of NCs, the RBC aggregation in plasma satisfies the 'cross-bridges' model. Complementarily, the allocation of NCs on the RBC membrane was observed by scanning electron microscopy (SEM), while for assessment of NCs-induced morphological changes the tests with the human mesenchymal stem cells (hMSC) was performed. The combined application of OT and advanced microscopy approaches brings new insights into the conception of direct observation of cells interaction influenced by NCs for the estimation of possible cytotoxic effects.
Collapse
|
26
|
Influence of blood pulsation on diagnostic volume in pulse oximetry and photoplethysmography measurements: publisher's note. APPLIED OPTICS 2019; 58:9688. [PMID: 31873569 DOI: 10.1364/ao.58.009688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Indexed: 06/10/2023]
Abstract
This publisher's note corrects several errors in Appl. Opt.58, 9398 (2019).APOPAI0003-693510.1364/AO.58.009398.
Collapse
|
27
|
Influence of blood pulsation on diagnostic volume in pulse oximetry and photoplethysmography measurements. APPLIED OPTICS 2019; 58:9398-9405. [PMID: 31873531 DOI: 10.1364/ao.58.009398] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 10/25/2019] [Indexed: 05/27/2023]
Abstract
Recent advances in the development of ultra-compact semiconductor lasers and technology of printed flexible hybrid electronics have opened broad perspectives for the design of new pulse oximetry and photoplethysmography devices. Conceptual design of optical diagnostic devices requires careful selection of various technical parameters, including spectral range; polarization and intensity of incident light; actual size, geometry, and sensitivity of the detector; and mutual position of the source and detector on the surface of skin. In the current study utilizing a unified Monte Carlo computational tool, we explore the variations in diagnostic volume due to arterial blood pulsation for typical transmitted and back-scattered probing configurations in a human finger. The results of computational studies show that the variations in diagnostic volumes due to arterial pulse wave are notably (up to 45%) different in visible and near-infrared spectral ranges in both transmitted and back-scattered probing geometries. While these variations are acceptable for relative measurements in pulse oximetry and/or photoplethysmography, for absolute measurements, an alignment normalization of diagnostic volume is required and can be done by a computational approach utilized in the framework of the current study.
Collapse
|
28
|
Hyperspectral imaging of human skin aided by artificial neural networks. BIOMEDICAL OPTICS EXPRESS 2019; 10:3545-3559. [PMID: 31467793 PMCID: PMC6706048 DOI: 10.1364/boe.10.003545] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 06/06/2019] [Accepted: 06/11/2019] [Indexed: 05/06/2023]
Abstract
We developed a compact, hand-held hyperspectral imaging system for 2D neural network-based visualization of skin chromophores and blood oxygenation. State-of-the-art micro-optic multichannel matrix sensor combined with the tunable Fabry-Perot micro interferometer enables a portable diagnostic device sensitive to the changes of the oxygen saturation as well as the variations of blood volume fraction of human skin. Generalized object-oriented Monte Carlo model is used extensively for the training of an artificial neural network utilized for the hyperspectral image processing. In addition, the results are verified and validated via actual experiments with tissue phantoms and human skin in vivo. The proposed approach enables a tool combining both the speed of an artificial neural network processing and the accuracy and flexibility of advanced Monte Carlo modeling. Finally, the results of the feasibility studies and the experimental tests on biotissue phantoms and healthy volunteers are presented.
Collapse
|
29
|
Abstract
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.
Collapse
|
30
|
NUTRITION FOR CORRECTING METABOLISM DISORDERS OF THE JOINT-LIGAMENT SYSTEM IN PHYSICALLY ACTIVE PEOPLE. HUMAN SPORT MEDICINE 2019. [DOI: 10.14529/hsm190115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Aim. The article deals with developing and assessing the efficiency of a complex nutritional support program for the joint-ligament system in athletes and physically active people. Materials and methods. The clinical evidence of biologically active substance (BAS) efficiency and functional orientation was obtained from the representative group of people with knee-joint osteoarthrosis. The main group of participants received a BAS complex with synergistic properties in terms of metabolism correction during osteoarthrosis: BAS 1 – 2 pills, BAS 2 – 1 capsule (2 times per day, 12 weeks), and BAS 3 – 1 capsule (2 times per day, 8 weeks). Nonsteroidal anti-inflammatory drugs were also prescribed to participants from the main and control groups. We used the general and special methods for assessing the quality and functional properties of specialized products. Knee joints were studied by using the Lequesne index (scores) characterizing pain syndrome, maximal distance, and daily movement activity. The intensity of pain syndrome was assessed with the visual analog scale (VAS, in mm). Results. We provided a scientific justification for the qualitative and quantitative content of BAS recipes for complex nutritional support of the joint-ligament system: BAS 1 – chondroprotective orientation; BAS 2 – an optimal source of minerals and vitamins; BAS 3 – polyunsaturated fatty acids. The results obtained revealed that specialized products improve the movement activity of participants with osteoarthrosis and significantly decrease pain syndrome (36 %). Apart from a chondroprotective effect such nutrition provides an anti-inflammatory effect and allows decreasing the intake of Nonsteroidal anti-inflammatory drugs in the absence of side effects. We revealed an insignificant number of disease recurrence – 6.7% (in the control group – 36.5 %) and established the mechanisms of such an influence. Conclusion. The application of biologically active complexes could serve as a reliable means of preventing and treating the diseases of the joint-ligament system, providing physical performance, and preserving health in athletes and physically active people.
Collapse
|
31
|
Mueller-matrix-based polarization imaging and quantitative assessment of optically anisotropic polycrystalline networks. PLoS One 2019; 14:e0214494. [PMID: 31095594 PMCID: PMC6522018 DOI: 10.1371/journal.pone.0214494] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 03/15/2019] [Indexed: 11/18/2022] Open
Abstract
We introduce a Mueller-matrix imaging polarization-based approach for the quantitative digital screening of the polycrystalline structure of fibrillary-based biological tissues in vitro. The morphometric evaluation of histological sections of myocardium was performed utilizing the high-order statistical moments calculated based on the spatial distribution of linear and circular birefringence and dichroism obtained experimentally. We demonstrate that spatial distributions of phase of light and optical anisotropy of scattering inherent to fibrillar networks of myocardium at different necrotic stages can be effectively used as a quantitative marker of stages of myosin fibril degradation. Processing the images of phase of light scattered in biological tissues with high order statistical analysis provides a functional tool for the quantitative characterization of necrotic conditions of the myocardium.
Collapse
|
32
|
Abstract
Despite extensive studies on different types of nanoparticles as potential drug carriers, the application of red blood cells (RBCs) as natural transport agents for systemic drug delivery is considered a new paradigm in modern medicine and possesses great potential. There is a lack of studies on the influence of drug carriers of different compositions on RBCs, especially regarding their potential impact on human health. Here, we apply conventional microscopy to observe the formation of RBC aggregates and optical tweezers to quantitatively assess the mutual interaction of RBCs incubated with inorganic and polymeric nanoparticles. Scanning electron microscopy is utilized for direct observation of nanoparticle localization on RBC membranes. The experiments are performed in a platelet-free blood plasma mimicking the RBC natural environment. We show that nanodiamonds influence mutual RBC interactions more antagonistically than other nanoparticles, resulting in higher aggregation forces and the formation of larger cell aggregates. In contrast, polymeric particles do not cause anomalous RBC aggregation. The results emphasize the application of optical tweezers for the direct quantitative assessment of the mutual interaction of RBCs influenced by nanomaterials.
Collapse
|
33
|
Mutual interaction of red blood cells assessed by optical tweezers and scanning electron microscopy imaging. OPTICS LETTERS 2018; 43:3921-3924. [PMID: 30106917 DOI: 10.1364/ol.43.003921] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Accepted: 07/12/2018] [Indexed: 05/20/2023]
Abstract
The adhesion of red blood cells (RBC) has been studied extensively in frame of cell-to-cell interaction induced by dextran macromolecules, whereas the data are lacking for native plasma solution. We apply optical tweezers to investigate the induced adhesion of RBC in plasma and in dextran solution. Two hypotheses, cross-bridges and depletion layer, are typically used to describe the mechanism of cell interaction; however, both mechanisms need to be confirmed experimentally. These interactions in fact are very much dependent on the size and concentration of dextran and proteins in plasma. The results show that in different dextran solutions, the interaction of adhering RBC agrees well with the quantitative predictions obtained based on the depletion-induced cells adhesion model, whereas the migrating cross-bridges model is more appropriate for plasma. Despite the different mechanisms of RBC interaction in a mixture of dextran with the size ranges and volume fraction proportional to plasma proteins, the dependence of RBC adhering tends to be close to the cross-bridges model. The induced aggregation of RBC in the dextran solutions and in native plasma are observed by direct visualization utilizing scanning electron microscopy.
Collapse
|
34
|
Assessment of the dynamics of human glymphatic system by near-infrared spectroscopy. JOURNAL OF BIOPHOTONICS 2018; 11:e201700123. [PMID: 28802090 DOI: 10.1002/jbio.201700123] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2017] [Revised: 07/25/2017] [Accepted: 08/10/2017] [Indexed: 06/07/2023]
Abstract
Fluctuations in brain water content has attracted increasing interest, particularly as regards studies of the glymphatic system, which is connected with the complex organization of dural lymphatic vessels, responsible for cleaning tissue. Disturbances of glymphatic circulation are associated with several brain disorders, including dementia. This article introduces an approach to noninvasive measurement of water dynamics in the human brain utilizing near-infrared spectroscopy (NIRS). We demonstrate the possibility to sense dynamic variations of water content between the skull and grey matter, for instance, in the subarachnoid space. Measured fluctuations in water content, especially in the cerebrospinal fluid (CSF), are assumed to be correlated with the dynamics of glymphatic circulation. The sampling volume for the NIRS optode was estimated by Monte Carlo modelling for the wavelengths of 660, 740, 830 and 980 nm. In addition, using combinations of these wavelengths, this article presents the calculation models for quantifying water and haemodynamics. The presented NIRS technique allows long-term functional brain monitoring, including sleeping time. Furthermore, it is used in combination with different magnetic neuroimaging techniques, particularly magnetic resonance encephalography. Using the combined setup, we report the preliminary results on the interaction between CSF and blood oxygen level-dependent fluctuations.
Collapse
|
35
|
Assisted Medication Management in Elderly Care Using Miniaturised Near-Infrared Spectroscopy. ACTA ACUST UNITED AC 2018. [DOI: 10.1145/3214272] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Near-infrared spectroscopy (NIRS) measures the light reflected from objects to infer highly detailed information about their molecular composition. Traditionally, NIRS has been an instrument reserved for laboratory usage, but recently affordable and smaller devices for NIRS have proliferated. Pairing this technology with the ubiquitous smartphone opens up a plethora of new use cases. In this paper, we explore one such use case, namely medication management in a nursing home/elderly care centre. First, we conducted a qualitative user study with nurses working in an elderly care centre to examine the protocols and workflows involved in administering medication, and the nurses' perceptions on using this technology. Based on our findings, we identify the main impact areas that would benefit from introducing miniaturised NIRS. Finally, we demonstrate via a user study in a realistic scenario that miniaturised NIRS can be effectively used for medication management when leveraging appropriate machine learning techniques. Specifically, we assess the performance of multiple pre-processing and classification algorithms for a selected set of pharmaceuticals. In addition, we compare our solution with currently used methods for pharmaceutical identification in a local care centre. We hope that our reflection on the multiple aspects associated with the introduction of this device in an elderly care setting can help both academics and practitioners working on related problems.
Collapse
|
36
|
Random networks of core-shell-like Cu-Cu 2O/CuO nanowires as surface plasmon resonance-enhanced sensors. Sci Rep 2018; 8:4708. [PMID: 29549337 PMCID: PMC5856813 DOI: 10.1038/s41598-018-23119-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Accepted: 03/01/2018] [Indexed: 12/20/2022] Open
Abstract
The rapid oxide formation on pristine unprotected copper surfaces limits the direct application of Cu nanomaterials in electronics and sensor assemblies with physical contacts. However, it is not clear whether the growing cuprous (Cu2O) and cupric oxides (CuO) and the formation of core-shell-like Cu-Cu2O/CuO nanowires would cause any compromise for non-contact optical measurements, where light absorption and subsequent charge oscillation and separation take place such as those in surface plasmon-assisted and photocatalytic processes, respectively. Therefore, we analyze how the surface potential of hydrothermally synthetized copper nanowires changes as a function of time in ambient conditions using Kelvin probe force microscopy in dark and under light illumination to reveal charge accumulation on the nanowires and on the supporting gold substrate. Further, we perform finite element modeling of the optical absorption to predict plasmonic behavior of the nanostructures. The results suggest that the core-shell-like Cu-Cu2O/CuO nanowires may be useful both in photocatalytic and in surface plasmon-enhanced processes. Here, by exploiting the latter, we show that regardless of the native surface oxide formation, random networks of the nanowires on gold substrates work as excellent amplification media for surface-enhanced Raman spectroscopy as demonstrated in sensing of Rhodamine 6G dye molecules.
Collapse
|
37
|
|
38
|
Smartphone snapshot mapping of skin chromophores under triple-wavelength laser illumination. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:91508. [PMID: 28253387 DOI: 10.1117/1.jbo.22.9.091508] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Accepted: 02/10/2017] [Indexed: 05/12/2023]
Abstract
Chromophore distribution maps are useful tools for skin malformation severity assessment and for monitoring of skin recovery after burns, surgeries, and other interactions. The chromophore maps can be obtained by processing several spectral images of skin, e.g., captured by hyperspectral or multispectral cameras during seconds or even minutes. To avoid motion artifacts and simplify the procedure, a single-snapshot technique for mapping melanin, oxyhemoglobin, and deoxyhemoglobin of in-vivo skin by a smartphone under simultaneous three-wavelength (448–532–659 nm) laser illumination is proposed and examined. Three monochromatic spectral images related to the illumination wavelengths were extracted from the smartphone camera RGB image data set with respect to crosstalk between the RGB detection bands. Spectral images were further processed accordingly to Beer’s law in a three chromophore approximation. Photon absorption path lengths in skin at the exploited wavelengths were estimated by means of Monte Carlo simulations. The technique was validated clinically on three kinds of skin lesions: nevi, hemangiomas, and seborrheic keratosis. Design of the developed add-on laser illumination system, image-processing details, and the results of clinical measurements are presented and discussed.
Collapse
|
39
|
Combined use of laser Doppler flowmetry and skin thermometry for functional diagnostics of intradermal finger vessels. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:40502. [PMID: 28399196 DOI: 10.1117/1.jbo.22.4.040502] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2016] [Accepted: 03/22/2017] [Indexed: 05/22/2023]
Abstract
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
Collapse
|
40
|
Finite difference methods for solving the transport equation in the problems of optical biomedical diagnostics. JOURNAL OF BIOMEDICAL PHOTONICS & ENGINEERING 2017. [DOI: 10.18287/jbpe17.03.010311] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
41
|
Poster session 2Morphogenetic mechanisms290MiR-133 regulates retinoic acid pathway during early cardiac chamber specification291Bmp2 regulates atrial differentiation through miR-130 during early heart looping formationDevelopmental genetics294Association of deletion allele of insertion/deletion polymorphism in alpha 2B adrenoceptor gene and hypertension with or without type 2 diabetes mellitus295Association of G1359A polymorphism of the endocannabinoid type 1 receptor (CNR1) with coronary artery disease (CAD) with type 2 diabetes mellitusCell growth, differentiation and stem cells - Vascular298Gamma-secretase inhibitor prevents proliferation and migration of ductus arteriosus smooth muscle cells: a role of Notch signaling in postnatal closure of ductus arteriosus299Mesenchymal stromal-like cells (MLCs) derived from induced pluripotent stem (iPS) cells: a promising therapeutic option to promote neovascularization300Sonic Hedgehog promotes mesenchymal stem cell differentiation to vascular smooth muscle cells in cardiovacsular disease301Proinflammatory cytokine secretion and epigenetic modification in endothelial cells treated LPS-GinfivalisCell death and apoptosis - Vascular304Mitophagy acts as a safeguard mechanism against human vascular smooth muscle cell apoptosis induced by atherogenic lipidsTranscriptional control and RNA species - Vascular307MicroRNA-34a role in vascular calcification308Local delivery of a miR-146a inhibitor utilizing a clinically applicable approach attenuates neointima formation after vascular injury309Long noncoding RNA landscape of hypoxic endothelial cells310Specific circulating microRNAs levels associate with hypertension, hyperglycemia and dysfunctional HDL in acute coronary syndrome patientsCytokines and cellular inflammation - Vascular313Phosphodiesterase5A up-regulation in vascular endothelium under pro-inflammatory conditions: a newly disclosed anti-inflammatory activity for the omega-3polyunsaturated aatty acid docosahexaenoic acid314Cardiovascular risk modifying with extra-low dose anticytokine drugs in rhematoid arthritis315Conversion of human M-CSF macrophages into foam cells reduces their proinflammatory responses to classical M1-polarizing activation316Lymphocytic myocarditis coincides with increased plaque inflammation and plaque hemorrhage in coronary arteries, facilitating myocardial infarction317Serum osteoprotegerin level predictsdeclined numerous of circulating endothelial- derived and mononuclear-derived progenitor cells in patients with metabolic syndromeGrowth factors and neurohormones - Vascular320Effect of gastrin-releasing peptide (GRP) on vascular inflammationSignal transduction - Heart323A new synthetic peptide regulates hypertrophy in vitro through means of the inhibition of nfkb324Inducible fibroblast-specific knockout of p38 alpha map kinase is cardioprotective in a mouse model of isoproterenol-induced cardiac hypertrophy325Regulation of beta-adrenoceptor-evoked inotropic responses by inhibitory G protein, adenylyl cyclase isoforms 5 and 6 and phosphodiesterases326Binding to RGS3 and stimulation of M2 muscarinic acetylcholine receptors modulates the substrate specificity of p190RhoGAP in cardiac myocytes327Cardiac regulation of post-translational modifications, parylation and deacetylation in LMNA dilated cardiomyopathy mouse model328Beta-adrenergic regulation of the b56delta/pp2a holoenzyme in cardiac myocytes through b56delta phosphorylation at serine 573Nitric oxide and reactive oxygen species - Vascular331Oxidative stress-induced miR-200c disrupts the regulatory loop among SIRT1, FOXO1 and eNOS332Antioxidant therapy prevents oxidative stress-induced endothelial dysfunction and Enhances Wound Healing333Morphological and biochemical characterization of red blood cell in coronary artery diseaseCytoskeleton and mechanotransduction - Heart336Novel myosin activator, JSH compounds, increased myocardial contractility without chronotropic effect in ratsExtracellular matrix and fibrosis - Vascular339Ablation of Toll-like receptor 9 causes cardiac rupture after myocardial infarction by attenuating proliferation and differentiation of cardiac fibroblasts340Altered vascular remodeling in the mouse hind limb ischemia model in Factor VII activating protease (FSAP) deficiencyVasculogenesis, angiogenesis and arteriogenesis343Pro-angiogenic effects of proly-hydroxylase inhibitors and their potential for use in a novel strategy of therapeutic angiogenesis for coronary total occlusion344Nrf2 drives angiogenesis in transcription-independent manner: new function of the master regulator of oxidative stress response345Angiogenic gene therapy, despite efficient vascular growth, is not able to improve muscle function in normoxic or chronically ischemic rabbit hindlimbs -role of capillary arterialization and shunting346Effect of PAR-1 inhibition on collateral vessel growth in the murine hind limb model347Quaking is a key regulator of endothelial cell differentiation, neovascularization and angiogenesis348"Emerging angiogenesis" in the chick chorioallantoic membrane (CAM). An in vivo study349Exosomes from cardiomyocyte progenitor cells and mesenchymal stem cells stimulate angiogenesis in vitro and in vivo via EMMPRINEndothelium352Reciprocal regulation of GRK2 and bradykinin receptor stimulation modulate Ca2+ intracellular level in endothelial cells353The roles of bone morphogenetic proteins 9 and 10 in endothelial inflammation and atherosclerosis354The contribution of GPR55 to the L-alpha-lysophosphatidylinositol-induced vasorelaxation in isolated human pulmonary arteries355The endothelial protective ACE inhibitor Zofenoprilat exerts anti-inflammatory activities through H2S production356A new class of glycomimetic drugs to prevent free fatty acid-induced endothelial dysfunction357Endothelial progenitor cells to apoptotic endothelial cell-derived microparticles ration differentiatesas preserved from reduced ejection fractionheart failure358Proosteogenic genes are activated in endothelial cells of patients with thoracic aortic aneurysm359Endothelin ETB receptors mediate relaxing responses to insulin in pericardial resistance arteries from patients with cardiovascular disease (CVD)Smooth muscle and pericytes362CX3CR1 positive myeloid cells regulate vascular smooth muscle tone by inducing calcium oscillations via activation of IP3 receptors363A novel function of PI3Kg on cAMP regulation, role in arterial wall hyperplasia through modulation of smooth muscle cells proliferation364NRP1 and NRP2 play important roles in the development of neointimal hyperplasia in vivo365Azithromycin induces autophagy in aortic smooth muscle cellsCoagulation, thrombosis and platelets368The real time in vivo evaluation of platelet-dependent aldosterone prothrombotic action in mice369Development of a method for in vivo detection of active thrombi in mice370The antiplatelet effects of structural analogs of the taurine chloramine371The influence of heparin anticoagulant drugs on functional state of human platelets372Regulation of platelet aggregation and adenosine diphosphate release by d dimer in acute coronary syndrome (in vitro study)Oxygen sensing, ischaemia and reperfusion375Sirtuin 5 mediates brain injury in a mouse model of cerebral ischemia-reperfusion376Abscisic acid: a new player in cardiomyocyte protection from ischaemia?377Protective effects of ultramicronized palmitoylethanolamide (PEA-um) in myocardial ischaemia and reperfusion injury in vivo378Identification of stem cell-derived cardiomyocytes using cardiac specific markers and additional testing of these cells in simulated ischemia/reperfusion system379Single-dose intravenous metformin treatment could afford significant protection of the injured rat kidney in an experimental model of ischemia-reperfusion380Cardiotoxicity of long acting muscarinic receptor antagonists used for chronic obstructive pulmonary disease381Dependence antioxidant potential on the concentration of amino acids382The impact of ischemia-reperfusion on physiological parameters,apoptosis and ultrastructure of rabbit myocardium with experimental aterosclerosisMitochondria and energetics385MicroRNA-1 dependent regulation of mitochondrial calcium uniporter (MCU) in normal and hypertrophied hearts386Mitochondrial homeostasis and cardioprotection: common targets for desmin and aB-crystallin387Overexpression of mitofusin-2 (Mfn2) and associated mitochondrial dysfunction in the diabetic heart388NO-dependent prevention of permeability transition pore (MPTP) opening by H2S and its regulation of Ca2+ accumulation in rat heart mitochondria389G protein coupled receptor kinase 2 (GRK2) is fundamental in recovering mitochondrial morphology and function after exposure to ionizing radiation (IR)Gender issues392Sex differences in pulmonary vascular control; focus on the nitric oxide pathwayAging395Heart failure with preserved ejection fraction develops when feeding western diet to senescence-accelerated mice396Cardiovascular markers as predictors of cognitive decline in elderly hypertensive patients397Changes in connexin43 in old rats with volume overload chronic heart failureGenetics and epigenetics400Calcium content in the aortic valve is associated with 1G>2G matrix metalloproteinase 1 polymorphism401Neuropeptide receptor gene s (NPSR1) polymorphism and sleep disturbances402Endothelin-1 gene Lys198Asn polymorphism in men with essential hypertension complicated and uncomplicated with chronic heart failure403Association of common polymorphisms of the lipoprotein lipase and pon1 genes with the metabolic syndrome in a sample of community participantsGenomics, proteomics, metabolomics, lipidomics and glycomics405Gene expression quantification using multiplexed color-coded probe pairs to determine RNA content in sporadic cardiac myxoma406Large-scale phosphorylation study of the type 2 diabetic heart subjected to ischemia / reperfusion injury407Transcriptome-based identification of new anti-inflammatory properties of the olive oil hydroxytyrosol in vascular endothelial cell under basal and proinflammatory conditions408Gene polymorphisms combinations and risk of myocardial infarctionComputer modelling, bioinformatics and big data411Comparison of the repolarization reserve in three state-of-the-art models of the human ventricular action potentialMetabolism, diabetes mellitus and obesity414Endothelial monocyte-activating polypeptide-II improves heart function in type -I Diabetes mellitus415Admission glucose level is independent predictor of impaired left ventricular function in patients with acute myocardial infarction: a two dimensional speckle-tracking echocardiography study416Association between biochemical markers of lipid profile and inflammatory reaction and stiffness of the vascular wall in hypertensive patients with abdominal obesity417Multiple common co-morbidities produce left ventricular diastolic dysfunction associated with coronary microvascular dysfunction, oxidative stress and myocardial stiffening418Investigating the cardiovascular effects of antiretroviral drugs in a lean and high fat/sucrose diet rat model of obesity419Statins in the treatment of non-alcoholic steatohepatitis (NASH). Our experience from a 2-year prospective study in Constanta County, Romania420Epicardial adipose tissue as a predictor of cardiovascular outcome in patients with ACS undergoing PCI?Arterial and pulmonary hypertension423Dependence between heart rhythm disorers and ID polymorphism of ACE gene in hypertensive patients424Molecular mechanisms underlying the beneficial effects of Urocortin 2 in pulmonary arterial hypertension425Inhibition of TGf-b axis and action of renin-angiotensin system in human ascending aorta aneurysms426Early signs of microcirculation and macrocirculation abnormalities in prehypertension427Vascular smooth muscle cell-expressed Tie-2 controls vascular tone428Cardiac and vascular remodelling in the development of chronic thrombo-embolic pulmonary hypertension in a novel swine modelBiomarkers431Arrhythmogenic cardiomyopathy: a new, non invasive biomarker432Can circulating microRNAs distinguish type 1 and type 2 myocardial infarction?433Design of a high-throughput multiplex proteomics assay to identify left ventricular diastolic dysfunction in diabetes434Monocyte-derived and P-selectin-carrying microparticles are differently modified by a low fat diet in patients with cardiovascular risk factors who will and who will not develop a cardiovascular event435Red blood cell distribution width assessment by polychromatic interference microscopy of thin films in chronic heart failure436Invasive and noninvasive evaluation of quality of radiofrequency-induced cardiac denervation in patients with atrial fibrillation437The effect of therapeutic hypothermia on the level of brain derived neurotrophic factor (BDNF) in sera following cardiopulmonary resustitation438Novel biomarkers to predict outcome in patients with heart failure and severe aortic stenosis439Biological factors linking depression and anxiety to cardiovascular disease440Troponins and myoglobin dynamic at coronary arteries graftingInvasive, non-invasive and molecular imaging443Diet composition effects on the genetic typing of the mouse ob mutation: a micro-ultrasound characterization of cardiac function, macro and micro circulation and liver steatosis444Characterization of pig coronary and rabbit aortic lesions using IV-OCT quantitative analysis: correlations with histologyGene therapy and cell therapy447Enhancing the survival and angiogenic potential of mouse atrial mesenchymal cells448VCAM-1 expression in experimental myocardial infarction and its relation to bone marrow-derived mononuclear cell retentionTissue engineering451Advanced multi layered scaffold that increases the maturity of stem cell-derived human cardiomyocytes452Response of engineered heart tissue to simulated ischemia/reperfusion in the presence of acute hyperglycemic conditions453Serum albumin hydrogels prevent de-differentiation of neonatal cardiomyocytes454A novel paintbrush technique for transfer of low viscosity ultraviolet light curable cyan methacrylate on saline immersed in-vitro sheep heart. Cardiovasc Res 2016. [DOI: 10.1093/cvr/cvw149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
42
|
Quantification of cell-free layer thickness and cell distribution of blood by optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:40501. [PMID: 27071412 DOI: 10.1117/1.jbo.21.4.040501] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Accepted: 03/22/2016] [Indexed: 05/25/2023]
Abstract
A high-speed optical coherence tomography (OCT) with 1-μm 1-μm axial resolution was applied to assess the thickness of a cell-free layer (CFL) and a spatial distribution of red blood cells (RBC) next to the microchannel wall. The experiments were performed in vitro in a plain glass microchannel with a width of 2 mm and height of 0.2 mm. RBCs were suspended in phosphate buffered saline solution at the hematocrit level of 45%. Flow rates of 0.1 to 0.5 ml/h 0.5 ml/h were used to compensate gravity induced CFL. The results indicate that OCT can be efficiently used for the quantification of CFL thickness and spatial distribution of RBCs in microcirculatory blood flow.
Collapse
|
43
|
The microphysics of collisionless shock waves. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2016; 79:046901. [PMID: 27007555 DOI: 10.1088/0034-4885/79/4/046901] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Collisionless shocks, that is shocks mediated by electromagnetic processes, are customary in space physics and in astrophysics. They are to be found in a great variety of objects and environments: magnetospheric and heliospheric shocks, supernova remnants, pulsar winds and their nebulæ, active galactic nuclei, gamma-ray bursts and clusters of galaxies shock waves. Collisionless shock microphysics enters at different stages of shock formation, shock dynamics and particle energization and/or acceleration. It turns out that the shock phenomenon is a multi-scale non-linear problem in time and space. It is complexified by the impact due to high-energy cosmic rays in astrophysical environments. This review adresses the physics of shock formation, shock dynamics and particle acceleration based on a close examination of available multi-wavelength or in situ observations, analytical and numerical developments. A particular emphasis is made on the different instabilities triggered during the shock formation and in association with particle acceleration processes with regards to the properties of the background upstream medium. It appears that among the most important parameters the background magnetic field through the magnetization and its obliquity is the dominant one. The shock velocity that can reach relativistic speeds has also a strong impact over the development of the micro-instabilities and the fate of particle acceleration. Recent developments of laboratory shock experiments has started to bring some new insights in the physics of space plasma and astrophysical shock waves. A special section is dedicated to new laser plasma experiments probing shock physics.
Collapse
|
44
|
Imaging of subchondral bone by optical coherence tomography upon optical clearing of articular cartilage. JOURNAL OF BIOPHOTONICS 2016; 9:270-5. [PMID: 26097171 DOI: 10.1002/jbio.201500130] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 05/01/2015] [Accepted: 05/19/2015] [Indexed: 05/10/2023]
Abstract
Optical clearing is an effective method to reduce light scattering of biological tissues that provides significant enhancement of light penetration into the biological tissues making non-invasive diagnosis more feasible. In current report Optical Coherence Tomography (OCT) in conjunction with optical clearing is applied for assessment of deep cartilage layers and cartilage-bone interface. The solution of Iohexol in water has been used as an optical clearing agent. The cartilage-bone boundary becomes visible after 15 min of optical clearing that enabling non-invasive estimation of its roughness: Sa = 10 ± 1 µm. The results show that for 0.9 mm thick cartilage optical clearing is stopped after 50 min with an increase of refractive index from 1.386 ± 0.008 to 1.510 ± 0.009. Current approach enables more reliable detection of arthroscopically inaccessible regions, including cartilage-bone boundary and subchondral bone, and potentially improves accuracy of the osteoarthritis diagnosis.
Collapse
|
45
|
Imaging of subchondral bone by optical coherence tomography upon optical clearing of articular cartilage. JOURNAL OF BIOPHOTONICS 2016; 9:270-275. [PMID: 26097171 DOI: 10.1002/jbio.v9.3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 05/01/2015] [Accepted: 05/19/2015] [Indexed: 05/26/2023]
Abstract
Optical clearing is an effective method to reduce light scattering of biological tissues that provides significant enhancement of light penetration into the biological tissues making non-invasive diagnosis more feasible. In current report Optical Coherence Tomography (OCT) in conjunction with optical clearing is applied for assessment of deep cartilage layers and cartilage-bone interface. The solution of Iohexol in water has been used as an optical clearing agent. The cartilage-bone boundary becomes visible after 15 min of optical clearing that enabling non-invasive estimation of its roughness: Sa = 10 ± 1 µm. The results show that for 0.9 mm thick cartilage optical clearing is stopped after 50 min with an increase of refractive index from 1.386 ± 0.008 to 1.510 ± 0.009. Current approach enables more reliable detection of arthroscopically inaccessible regions, including cartilage-bone boundary and subchondral bone, and potentially improves accuracy of the osteoarthritis diagnosis.
Collapse
|
46
|
Spatial evolution of depolarization in homogeneous turbid media within the differential Mueller matrix formalism. OPTICS LETTERS 2015; 40:5634-7. [PMID: 26625069 DOI: 10.1364/ol.40.005634] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
We show, through visible-range Mueller polarimetry, as well as numerical simulations, that the depolarization in a homogeneous turbid medium consisting of submicron spherical particles follows a parabolic law with the path-length traveled by light through the medium. This result is in full agreement with the phenomenological theory of the fluctuating medium within the framework of the differential Mueller matrix formalism. We further found that the standard deviations of the fluctuating elementary polarization properties of the medium depend linearly on the concentration of particles. These findings are believed to be useful for the phenomenological interpretation of polarimetric experiments, with special emphasis on biomedical applications.
Collapse
|
47
|
Depletion of carbon nanotube depositions and tube realignment in the spreading of sessile drops. Colloids Surf A Physicochem Eng Asp 2015. [DOI: 10.1016/j.colsurfa.2015.06.055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
48
|
Optical properties of plasmon-resonant bare and silica-coated nanostars used for cell imaging. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:76017. [PMID: 26230637 DOI: 10.1117/1.jbo.20.7.076017] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Accepted: 06/26/2015] [Indexed: 05/11/2023]
Abstract
We synthesized and characterized gold nanostars and their silica-coated derivatives with 7- to 50-nm shell thicknesses as contrast agents for optical imaging. The scattering and absorption coefficients of the nanoparticles (NPs) were estimated by means of collimated transmittance and diffuse reflectance/transmittance analyses. The contrasting properties of the nanostructures were studied in optical coherence tomography glass capillary imaging. The silica-coated nanostars with the thickest shell have higher scattering ability in comparison with bare nanostars. Viability assays confirmed weak in vitro toxicity of nanostructures at up to ∼200-μg/mL concentrations. We showed real-time visualization of nanostars in both agarose and cultured cells by analyzing the backscattering signal using a conventional laser confocal microscope. The signal intensity detected from the silica-coated NPs was almost 1.5 times higher in comparison with bare nanostars. To the best of our knowledge, this is the first time that conventional laser confocal microscopy was applied in combined scattering and transmitted light modes to detect the backscattered signal of gold nanostars, which is useful for direct monitoring of the uptake, translocation, and accumulation of NPs in living cells.
Collapse
|
49
|
Evaluation of Freshness of Soft Tissue Samples with Optical Coherence Tomography Assisted by Low Frequency Electric Field. Sovrem Tekhnologii Med 2015. [DOI: 10.17691/stm2015.7.1.09] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
50
|
Formate supplementation can increase nickel recovery by Halothiobacillus halophilus. World J Microbiol Biotechnol 2015; 31:535-7. [PMID: 25613548 DOI: 10.1007/s11274-015-1805-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Accepted: 01/16/2015] [Indexed: 10/24/2022]
Abstract
Acidophilic thiobacilli are traditional biotechnological agents for metal recovery from sulfide ores. Major industrial strains belong to autotrophic bacteria which are used without any organic supplements to stimulate the process. The autotrophic strain Acidithiobacillus ferrooxidans ATCC 21834 is known to use formate as a source of energy under special laboratory conditions. We showed the presence of formate dehydrogenase in the type strain of another autotrophic species Halothiobacillus halophilus representing another genus of thiobacilli. This finding prompted studies of bioleaching stimulation by formate. Canadian sulfide nickel ore was chosen for model investigation as leached substrate and the moderate acidophilic strain H. halophilus DSM 6132 was used as the leaching agent. In bench-scale bioleaching experiments, inoculation of the ore with H. halophilus supplemented with 0.3 % formate increased the recovery of nickel 70-fold as compared with formate-free inoculation (1008.0 vs. 13.8 mg Ni/L per 34 days). Bacteria H. halophilus belong to moderate acidophilic microorganisms; thus, the results were obtained with initial pH 7.4 and final pH 5.4. The mechanism of formate stimulation is under discussion.
Collapse
|