1
|
18F-FDG PET/CT and radiolabeled leukocyte SPECT/CT imaging for the evaluation of cardiovascular infection in the multimodality context: ASNC Imaging Indications (ASNC I 2) Series Expert Consensus Recommendations from ASNC, AATS, ACC, AHA, ASE, EANM, HRS, IDSA, SCCT, SNMMI, and STS. Heart Rhythm 2024; 21:e1-e29. [PMID: 38466251 DOI: 10.1016/j.hrthm.2024.01.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.
Collapse
|
2
|
18F-FDG PET/CT and radiolabeled leukocyte SPECT/CT imaging for the evaluation of cardiovascular infection in the multimodality context: ASNC Imaging Indications (ASNC I 2) Series Expert Consensus Recommendations from ASNC, AATS, ACC, AHA, ASE, EANM, HRS, IDSA, SCCT, SNMMI, and STS. J Nucl Cardiol 2024; 34:101786. [PMID: 38472038 DOI: 10.1016/j.nuclcard.2023.101786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.
Collapse
|
3
|
18F-FDG PET/CT and radiolabeled leukocyte SPECT/CT imaging for the evaluation of cardiovascular infection in the multimodality context: ASNC Imaging Indications (ASNC I2) Series Expert Consensus Recommendations from ASNC, AATS, ACC, AHA, ASE, EANM, HRS, IDSA, SCCT, SNMMI, and STS. Clin Infect Dis 2024:ciae046. [PMID: 38466039 DOI: 10.1093/cid/ciae046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024] Open
Abstract
This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.
Collapse
|
4
|
18F-FDG PET/CT and Radiolabeled Leukocyte SPECT/CT Imaging for the Evaluation of Cardiovascular Infection in the Multimodality Context: ASNC Imaging Indications (ASNC I 2) Series Expert Consensus Recommendations From ASNC, AATS, ACC, AHA, ASE, EANM, HRS, IDSA, SCCT, SNMMI, and STS. JACC Cardiovasc Imaging 2024:S1936-878X(24)00036-6. [PMID: 38466252 DOI: 10.1016/j.jcmg.2024.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.
Collapse
|
5
|
Mortality Benefit Among Primary Prevention Implantable Cardioverter Defibrillator Recipients on Contemporary Heart Failure Treatment. JACC Clin Electrophysiol 2024:S2405-500X(24)00090-2. [PMID: 38520434 DOI: 10.1016/j.jacep.2024.102334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/19/2024] [Accepted: 01/20/2024] [Indexed: 03/25/2024]
Abstract
BACKGROUND Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.
Collapse
|
6
|
Extraction outcomes of implantable cardioverter-defibrillator leads vary by manufacturer and model family. Europace 2023; 25:euad345. [PMID: 38000893 PMCID: PMC10751850 DOI: 10.1093/europace/euad345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023] Open
Abstract
AIMS Transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads is considered challenging. The structure of each ICD leads is variable between manufacturer and model families. The net impact of lead family on the safety and effectiveness of TLE is poorly characterized. We assessed the safety and efficacy of ICD TLE and the impact of manufacturer ICD model family on the outcomes. METHODS AND RESULTS The study cohort included all consecutive patients with ICD who underwent TLE between 2013 and 2022 and are enrolled in the Cleveland Clinic Prospective TLE Registry. A total of 885 ICD leads (median implant duration 8 years) in 810 patients were included. Complete ICD TLE success was achieved in 97.2% of the leads (n = 860) and in 98.0% of the patients (n = 794). Major complications occurred in 22 patients (2.7%). Complete procedural success rate varied by manufacturer and lead family; Medtronic 98.9%, Abbott 95.9%, Boston Scientific 95.0%, Biotronik 91.2%, P = 0.03, and Linox family leads had the lowest, 89.7% P = 0.02. Multivariable predictors of incomplete ICD lead removal included ICD lead age > 10 years and Linox family lead. Multivariable predictors of major complications included ICD lead age > 15 years and longer lead extraction time, and predictors of all-cause mortality within 30 days included lead extraction for infection, end-stage renal disease, and higher New York Heart Association functional class. CONCLUSION Complete and safe ICD lead removal rate by TLE is extremely high but varied by manufacturer and lead family. Linox family lead and >10 years lead age were independent predictors of incomplete lead removal.
Collapse
|
7
|
Lead Extraction and Mortality Among Patients With Cardiac Implanted Electronic Device Infection. JAMA Cardiol 2023; 8:1165-1173. [PMID: 37851461 PMCID: PMC10585491 DOI: 10.1001/jamacardio.2023.3379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/05/2023] [Indexed: 10/19/2023]
Abstract
Importance Complete hardware removal is a class I recommendation for cardiovascular implantable electronic device (CIED) infection, but practice patterns and outcomes remain unknown. Objective To quantify the number of Medicare patients with CIED infections who underwent implantation from 2006 to 2019 and lead extraction from 2007 to 2019 to analyze the outcomes in these patients in a nationwide clinical practice cohort. Design, Setting, and Participants This cohort study included fee-for-service Medicare Part D beneficiaries from January 1, 2006, to December 31, 2019, who had a de novo CIED implantation and a CIED infection more than 1 year after implantation. Data were analyzed from January 1, 2005, to December 31, 2019. Exposure A CIED infection, defined as (1) endocarditis or infection of a device implant and (2) documented antibiotic therapy. Main Outcomes and Measures The primary outcomes of interest were device infection, device extraction, and all-cause mortality. Time-varying multivariable Cox proportional hazards regression models were used to evaluate the association between extraction and survival. Results Among 1 065 549 patients (median age, 78.0 years [IQR, 72.0-84.0 years]; 50.9% male), mean (SD) follow-up was 4.6 (2.9) years after implantation. There were 11 304 patients (1.1%) with CIED infection (median age, 75.0 years [IQR, 67.0-82.0 years]); 60.1% were male, and 7724 (68.3%) had diabetes. A total of 2102 patients with CIED infection (18.6%) underwent extraction within 30 days of diagnosis. Infection occurred a mean (SD) of 3.7 (2.4) years after implantation, and 1-year survival was 68.3%. There was evidence of highly selective treatment, as most patients did not have extraction within 30 days of diagnosed infection (9202 [81.4%]), while 1511 (13.4%) had extraction within 6 days of diagnosis and 591 (5.2%) had extraction between days 7 and 30. Any extraction was associated with lower mortality compared with no extraction (adjusted hazard ratio [AHR], 0.82; 95% CI, 0.74-0.90; P < .001). Extraction within 6 days was associated with even lower risk of mortality (AHR, 0.69; 95% CI, 0.61-0.78; P < .001). Conclusions and Relevance In this study, a minority of patients with CIED infection underwent extraction. Extraction was associated with a lower risk of death compared with no extraction. The findings suggest a need to improve adherence to guideline-directed care among patients with CIED infection.
Collapse
|
8
|
Algorithms and programming matters: implantable cardioverter defibrillator therapy in Biotronik and Abbott devices. J Interv Card Electrophysiol 2023; 66:1553-1554. [PMID: 36892801 DOI: 10.1007/s10840-023-01518-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 02/26/2023] [Indexed: 03/10/2023]
|
9
|
Images in Vascular Medicine: Valsalva purpura secondary to balloon occlusion of the cavoatrial junction during intervention for lead-induced SVC syndrome. Vasc Med 2023; 28:479-480. [PMID: 37650456 DOI: 10.1177/1358863x231191902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
10
|
Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial. Lancet 2023; 402:1147-1157. [PMID: 37634520 DOI: 10.1016/s0140-6736(23)00912-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/01/2023] [Accepted: 05/04/2023] [Indexed: 08/29/2023]
Abstract
BACKGROUND Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING Medtronic.
Collapse
|
11
|
The Challenge of Minimizing Unnecessary ICD Shocks While Also Preventing Syncope. JACC Clin Electrophysiol 2023; 9:2004. [PMID: 37758372 DOI: 10.1016/j.jacep.2023.06.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 06/08/2023] [Accepted: 06/09/2023] [Indexed: 10/03/2023]
|
12
|
Initial heart rate score predicts new-onset atrial tachyarrhythmias in pacemaker patients. Europace 2023; 25:euad242. [PMID: 37552791 PMCID: PMC10440628 DOI: 10.1093/europace/euad242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/01/2023] [Indexed: 08/10/2023] Open
Abstract
AIMS Heart rate score (HRSc), the per cent of atrial paced and sensed event in the largest 10 b.p.m. rate histogram bin of a pacemaker, predicts survival in patients with cardiac devices. No correlation between HRSc and development of atrial fibrillation (AF) has been reported. In this study, we evaluated the relationship between pacemaker post-implantation HRSc and the incidence of newly developed atrial tachyarrhythmias (ATAs). METHODS AND RESULTS Patients with dual-chamber pacemakers, implanted 2013-17, with the LATITUDE remote monitoring data with ≥600 000 beats of histogram data collected at baseline were included (N = 34 543). Heart rate score was determined from the initial 3-month post-implantation histogram data. Patients were excluded if they had ATAs, defined as atrial high-rate episodes >5 min or >1% of right atrial beats >170 b.p.m. during the initial 3 months post-implantation. New ATAs, after the baseline period, were defined by each of the following: >1, >10, or >25% of atrial beats >170 b.p.m. or atrial tachycardia response (ATR) events >24 h. Patients were followed a median of 2.8 (1.0-4.0) years. The incidence of ATAs increased in proportion to HRSc (log-rank P-value <0.001), and the initial HRSc ≥70% was associated with increased ATAs by all definitions. Patients with initial HRSc ≥70% were older, had a higher percentage of right atrium pacing (%RA pacing), had a lower percentage of right ventricular pacing (%RV pacing), and were more likely programmed with rate-response vs. subjects with HRSc <70%. Initial HRSc (hazard ratio: 1.07, 95% confidence interval: 1.05-1.09; P < 0.0001) independently predicted ATAs after adjusting for age, gender, %RV pacing, and rate-response programming. The %RA pacing and initial HRSc were correlated. CONCLUSION Heart rate score independently predicts any subsequent duration of ATAs in pacemaker patients.
Collapse
|
13
|
In Memoriam: Patrick Tchou, February 24, 1950, to April 18, 2023. Heart Rhythm 2023; 20:1078. [PMID: 37393097 DOI: 10.1016/j.hrthm.2023.05.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/10/2023] [Accepted: 05/10/2023] [Indexed: 07/03/2023]
|
14
|
Extraction of a 5-year-old leadless pacemaker using a competing manufacturer's removal tool. HeartRhythm Case Rep 2023; 9:441-444. [PMID: 37492061 PMCID: PMC10363471 DOI: 10.1016/j.hrcr.2023.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/27/2023] Open
|
15
|
Implantable Cardioverter-Defibrillator for Primary Prevention in Asia. JACC. ASIA 2023; 3:321-334. [PMID: 37323870 PMCID: PMC10261897 DOI: 10.1016/j.jacasi.2022.11.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 11/16/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
In a contemporary setting, where the risk of sudden cardiac death (SCD) is low, heart failure management is improved, and technology is advanced, identifying the patients who would benefit the most from an implantable cardioverter-defibrillator (ICD) treatment for primary prevention remains a challenge. The prevalence of SCD is lower in Asia when compared with the United States/Europe (35-45 per 100,000 person-years vs 55-100 per 100,000 person-years, respectively). Nevertheless, this should not explain the enormous gap in ICD's utilization among eligible candidates (∼12% in Asia vs ∼45% in the United States/Europe). The disparity between Asia and Western countries, together with significant variation among the Asian population and the previously mentioned challenges, requires an individualized approach and specific regional recommendation, especially in countries with limited resources where ICDs are being extremely underutilized This review focuses on the current knowledge of ICD therapy for SCD prevention and how to improve patient and device selection.
Collapse
|
16
|
Cardiac Implantable Electronic Devices and Infective Endocarditis: A Call to Arms…. J Am Coll Cardiol 2023; 81:1726-1728. [PMID: 37100489 DOI: 10.1016/j.jacc.2023.02.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 02/27/2023] [Indexed: 04/28/2023]
|
17
|
Clinical Predictors of Incomplete CS Lead Removal during Transvenous Lead Extraction in the Patients with Cardiac Resynchronization Therapy. Heart Rhythm 2023; 20:872-878. [PMID: 36933853 DOI: 10.1016/j.hrthm.2023.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/24/2023] [Accepted: 03/13/2023] [Indexed: 03/20/2023]
Abstract
BACKGROUND Reports of coronary sinus (CS) lead removal include small studies with short implant durations. Procedural outcomes for mature CS leads removed with long duration implantation are unavailable. OBJECTIVE To examine the safety, efficacy, and clinical predictors for incomplete CS lead removal by Transvenous Lead Extraction (TLE) in a large, long implant duration cardiac resynchronization therapy (CRT) patient cohort. METHODS Consecutive patients with CRT devices in the Cleveland Clinic Prospective TLE Registry who had TLE between 2013 and 2022. RESULTS CS leads, n=231, implant duration = 6.1±4.0 years, removed from 226 patients were included, employing powered sheaths for 137 leads (59.3%). Complete CS lead success was achieved in 95.2% of leads (n=220) and in 95.6% of patients (n=216). Major complications occurred in 5 patients (2.2%). Patients who had the CS lead extracted 1st had significantly higher incomplete removal rates than when the other leads were 1st removed. Multivariable analysis showed that older CS lead age (OR 1.35, 95% CI 1.01-1.82; P = 0.03), and removing the CS lead 1st (OR 7.48, 95% CI 1.02-54.95; P = 0.045) were independent predictors of incomplete CS lead removal. CONCLUSION Complete and safe lead removal rate of long implant duration CS leads by TLE was 95%. However, CS lead age and the order that leads were extracted were the independent predictors of incomplete CS lead removal. Therefore, before the CS lead is extracted, physicians should first extract the leads from the other chambers and employ powered sheaths.
Collapse
|
18
|
Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing. Heart Rhythm 2023; 20:902-909. [PMID: 36868544 DOI: 10.1016/j.hrthm.2023.02.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 02/17/2023] [Accepted: 02/24/2023] [Indexed: 03/04/2023]
Abstract
BACKGROUND With the advent of conduction system pacing, use of the Medtronic SelectSecure Model 3830 lead has increased substantially. However, with this increased use, the potential need for lead extraction also will increase. Lumenless lead construction requires an understanding of both applicable tensile forces as well as lead preparation techniques that can influence consistent extraction. OBJECTIVE The purpose of this study was to use bench testing methodologies to characterize the physical properties of lumenless leads and to describe related lead preparation methods that support known extraction techniques. METHODS Multiple 3830 lead preparation techniques, commonly used in extraction practices, were compared on the bench to assess rail strength (RS) in simple traction and use conditions with simulated scar. Retention of the IS1 connector vs severing the lead body preparation techniques were compared. Distal snare and rotational extraction tools were evaluated. RESULTS The retained connector method provided higher RS compared to the modified cut lead method: mean 11.42 lbf (9.85-12.73 lbf) vs 8.51 lbf (1.66-14.32 lbf), respectively. Snare use distally did not significantly affect RS: mean 11.05 lbf (8.58-13.95 lbf). Lead damage occurred with the TightRail extraction tool at angles ≥90°, which could occur with right-sided implants. CONCLUSIONS When extracting SelectSecure leads, the retained connector method to maintain cable engagement benefits preservation of the extraction RS. Limiting traction force to <10 lbf (4.5 kgf) and avoiding poor lead preparation methods are critical to consistent extraction. Femoral snaring does not change RS when needed and offers a method to regain lead rail in cases of distal cable fracture.
Collapse
|
19
|
Leadless pacing in patients undergoing transvenous lead extraction due to infection: A small step in a long journey. Heart Rhythm 2023; 20:861-862. [PMID: 36858160 DOI: 10.1016/j.hrthm.2023.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 03/02/2023]
|
20
|
Long-term outcomes in nonprogressors to cardiac resynchronization therapy. Heart Rhythm 2023; 20:165-170. [PMID: 36356725 DOI: 10.1016/j.hrthm.2022.10.029] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 10/22/2022] [Accepted: 10/31/2022] [Indexed: 11/09/2022]
Abstract
BACKGROUND Among patients with heart failure undergoing cardiac resynchronization therapy (CRT), patients with a minimal change in left ventricular ejection fraction (LVEF) have recently been defined as "nonprogressors" rather than as "nonresponders." Little is known regarding long-term outcomes of nonprogressors. OBJECTIVE We sought to evaluate outcomes in patients undergoing CRT on the basis of echocardiographically determined response status. METHODS We reviewed the medical charts of patients with an LVEF of ≤35% and a QRS duration of ≥120 ms undergoing CRT at the Cleveland Clinic, Johns Hopkins Hospital, and Johns Hopkins Bayview Medical Center between 2003 and 2014. Response to CRT was defined on the basis of LVEF change as follows: super-responders ≥20%, responders 6%-19%, nonprogressors 0%-5%, and progressors <0%. Survival free of left ventricular assist device (LVAD) implantation and heart transplantation was compared on the basis of response classification. RESULTS A total of 1058 patients were included and had a mean follow-up 8.7 ± 5.4 years, over which time there were 606 end points (37 LVAD implants, 32 heart transplants, and 537 deaths). Survival free of LVAD and heart transplant differed significantly between response groups after CRT both in the mid-term (4 years) and in the long-term (8.7 ± 5.4 years), with super-responders achieving the best outcomes and progressors the worst (P < .001). In multivariate analysis, nonprogressors had superior outcomes to progressors (P = .02) at 4 years of follow-up. Over the duration of follow-up (8.7 ± 5.4 years), there was no significant difference in survival between those 2 groups (P = .18). CONCLUSION Nonprogressors to CRT have superior medium-term outcomes but similar long-term outcomes to progressors and inferior outcomes to responders and super-responders.
Collapse
|
21
|
New atrial arrhythmia occurrence in single chamber implantable cardioverter defibrillator patients: A real-world investigation. J Cardiovasc Electrophysiol 2023; 34:438-444. [PMID: 36579406 PMCID: PMC10108104 DOI: 10.1111/jce.15790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 11/08/2022] [Accepted: 11/22/2022] [Indexed: 12/30/2022]
Abstract
INTRODUCTION A current limitation of single chamber implantable cardioverter defibrillators (ICDs) is the lack of an atrial lead to reliably detect atrial fibrillation (AF) episodes. A novel ventricular based atrial fibrillation (VBAF) detection algorithm was created for single chamber ICDs to assess R-R variability for detection of AF. METHODS Patients implanted with Visia AF™ ICDs were prospectively enrolled in the Medtronic Product Surveillance Registry from December 15, 2015 to January 23, 2019 and followed with at least 30 days of monitoring with the algorithm. Time to device-detected daily burden of AF ≥ 6 min, ≥6 h, and ≥23 h were reported. Clinical actions after device-detected AF were recorded. RESULTS A total of 291 patients were enrolled with a mean follow-up of 22.5 ± 7.9 months. Of these, 212 (73%) had no prior history of AF at device implant. However, 38% of these individuals had AF detected with the VBAF algorithm with daily burden of ≥6 min within two years of implant. In these 80 patients with newly detected AF by their ICD, 23 (29%) had a confirmed clinical diagnosis of AF by their provider. Of patients with a clinical diagnosis of AF, nine (39%) were newly placed on anticoagulation, including five of five (100%) patients having a burden >23 h. CONCLUSIONS Continuous AF monitoring with the new VBAF algorithm permits early identification and actionable treatment for patients with undiagnosed AF that may improve patient outcomes.
Collapse
|
22
|
Inappropriate mode switch and unwarranted right ventricular pacing during atrial fibrillation: Paradoxical atrial undersensing. J Arrhythm 2022; 38:1102-1105. [PMCID: PMC9745553 DOI: 10.1002/joa3.12791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/20/2022] [Accepted: 10/10/2022] [Indexed: 12/15/2022] Open
|
23
|
Prospective Evaluation of the Correlation Between Gated Cardiac Computed Tomography Detected Vascular Fibrosis and Ease of Transvenous Lead Extraction. Circ Arrhythm Electrophysiol 2022; 15:e010779. [PMID: 36306341 PMCID: PMC10503543 DOI: 10.1161/circep.121.010779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 09/30/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND Difficulty of lead extraction does not track well with procedural complications, but several small retrospective studies have lead fibrosis on computed tomography as an important indicator of difficult lead extraction. The purpose of the present study was to apply a standardized gated cardiac computed tomography (CT) protocol to assess fibrosis and study it prospectively to examine the need for powered sheaths and risk outcomes. METHODS We performed a prospective, blinded, multicenter, international study at high-volume lead extraction centers and included patients referred for transvenous lead extraction with at least one lead with a dwell time >1 year and ability to receive a cardiac CT. The degree of fibrosis (as measured by amount of lead adherence to vessel wall) was graded on a scale of 1 to 4 by dedicated CT readers in 3 zones (vein entry to superior vena cava, superior vena cava, and right atrium to lead tip). The primary outcome of the study was number of extractions requiring powered sheaths at zone 2 for each fibrosis group. RESULTS A total of 200 patients were enrolled in the trial with 196 completing full gated CT and lead extraction analysis. The primary endpoint of powered sheath (laser and mechanical) sheath use was significantly higher in patients with higher fibrosis seen on CT (scores 3+4; 67.8%) at the zone 2 compared to patients with lower fibrosis (scores 1+2; 38.6%; P<0.001). There were 5 major complications with 3 vascular lacerations all occurring in zone 2 in the study. CONCLUSIONS Gated, contrasted CT can predict the need for powered sheaths by identification of fibrosis but did not identify an absolute low-risk cohort who would not need powered sheaths. REGISTRATION URL: https://www. CLINICALTRIALS gov; Unique identifier: NCT03772704.
Collapse
|
24
|
Transvenous lead extraction in conduction system pacing. Front Physiol 2022; 13:993604. [PMID: 36035491 PMCID: PMC9410714 DOI: 10.3389/fphys.2022.993604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 07/22/2022] [Indexed: 12/02/2022] Open
Abstract
Conduction System Pacing (CSP) delivered by His Bundle Pacing (HBP) or Left Bundle Pacing (LBP) are exciting novel interventions in the field of Cardiac Resynchronization Therapy (CRT). As the evidence base for CSP grows, the volume of implants worldwide is projected to rise significantly in the coming years. As such, physicians will be confronted with increasingly prevalent and vital issues arising in long-term follow up, including the management of infected, malfunctioning, or redundant CSP leads. Transvenous lead extraction (TLE) is the first-line option for removal of pacing leads when indicated in these circumstances. The evidence base for TLE in the context of CSP is still in its infancy. In this article, we first provide a brief overview of TLE. We then examine the data on the long-term performance of HBP leads. Next, we describe the features of the Medtronic Select Secure 3,830 lead, and how experience of TLE of this lead in the paediatric population has informed our practice. Finally, we review the current evidence for TLE in HBP and LBP, and discuss how future studies can address gaps in our current knowledge.
Collapse
|
25
|
Successful defibrillation by modifying from fixed-tilt to tuned-duration defibrillation waveform: When less is more? HeartRhythm Case Rep 2022; 8:702-706. [PMID: 36310725 PMCID: PMC9596389 DOI: 10.1016/j.hrcr.2022.07.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
26
|
Risk factors for hematoma in patients undergoing cardiac device procedures: A WRAP-IT trial analysis. Heart Rhythm O2 2022; 3:466-473. [PMID: 36340491 PMCID: PMC9626743 DOI: 10.1016/j.hroo.2022.05.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 05/30/2022] [Indexed: 11/25/2022] Open
Abstract
Background Implant site hematoma is a known complication of cardiac device procedures and can lead to major consequences. Objectives To evaluate risk factors for hematoma and further understand the relationship between anticoagulant (AC), antiplatelet (AP) use, and hematoma development. Methods We included 6800 patients from the WRAP-IT trial. To assess baseline and procedural characteristics associated with hematoma within the first 30 days postprocedure, a stepwise Cox regression model was implemented with minimal Akaike information criterion. Cox regressions were also used to evaluate AC/AP use and hematoma risk. Results The overall rate of hematoma was 2.2%. The model identified 11 baseline and procedural characteristics associated with hematoma risk. AC use (hazard ratio [HR]: 2.44, P < .001), lower body mass index (HR: 1.06, P < .001), and history of valve surgery (HR: 2.11, P < .001) were associated with the highest risk. AP use, male sex, history of coronary artery disease, existing pocket, history of nonischemic cardiomyopathy, number of previous cardiac implantable electronic device (CIED) procedures, procedure time, and lead revision were associated with moderate risk. Antithrombotic use was high overall (86%) and AC+AP use was highly predictive of hematoma risk. Regardless of AC status, AP use was associated with an almost doubling of risk vs no AP (HR = 1.85, P = .0006) in the general cohort. Interruption of AC was associated with the lowest hematoma risk (HR = 2.35) while heparin bridging (HR = 4.98) and AP use vs no AP use (HR = 1.85) was associated with the highest hematoma risk. Conclusion The results of this analysis highlight risk factors associated with the development of hematoma in patients undergoing CIED procedures and can inform antithrombotic management.
Collapse
|
27
|
Erratum for "Influence of "high" defibrillation thresholds on patient survival and impact of system modification". J Cardiovasc Electrophysiol. 2022;33: 234-240. J Cardiovasc Electrophysiol 2022; 33:1349. [PMID: 35397132 DOI: 10.1111/jce.15460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
28
|
Influence of "high" defibrillation thresholds on patient survival and impact of system modification. J Cardiovasc Electrophysiol 2021; 33:234-240. [PMID: 34911148 DOI: 10.1111/jce.15326] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 08/20/2021] [Accepted: 10/20/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To test whether a high defibrillation threshold (DFT) marks patients with poor outcomes which are improved when DFT is decreased by system modification (subcutaneous coil implant; SM). BACKGROUND The electrical substrate generating fast ventricular arrhythmias may generate poor outcomes among patients treated with implantable cardioverter-defibrillators (ICDs), even when arrhythmias are treated successfully. Since patients with high DFTs have increased mortality, we contrasted survival among patients with high DFT treated with and without SM. METHODS We studied consecutive patients undergoing ICD implantation and DFT testing at Cleveland Clinic over a 14-year period. High DFT was defined as successful defibrillation by shock strength >25 J or ≤10 J of maximal device output. Mortality was recorded using the Social Security Death Index. Survival was compared among those high DFT patients receiving SM versus the remainder. RESULTS Out of 6353 patients tested, 191 (3%) had high DFT (32.1 ± 3.7 J) versus 13.9 ± 4.9 J in the remainder ("acceptable DFT," p < .001). One hundred twenty-one high DFT patients (63%; 33.3 ± 3.4 J) underwent SM, which significantly decreased DFT (24.8 ± 5.9 J; p < .001). Seventy patients (37%; 30.3 ± 3.3 J) did not undergo SM. During follow-up, 38% (2363/6162; 7.8 yrs) patients with acceptable DFT died versus 48% high DFT patients (91/191; 5.6 yrs.; p < .001). Concomitantly, 48% patients with SM (58/121) died, as compared to 47% patients (33/70) without SM (p = .91); median follow-up 4.9 yrs). CONCLUSION Patients with high DFT have a higher mortality than those with acceptable DFT. The additional subcutaneous coil implant decreases DFT to an acceptable range but does not appear to improve survival. The electrical substrate underlying high DFT appears to determine survival.
Collapse
|
29
|
Bradyarrhythmias detected by extended rhythm recording in patients undergoing transcatheter aortic valve replacement (Brady-TAVR Study). Heart Rhythm 2021; 19:381-388. [PMID: 34801735 DOI: 10.1016/j.hrthm.2021.11.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/31/2021] [Accepted: 11/14/2021] [Indexed: 12/29/2022]
Abstract
BACKGROUND Bradyarrhythmias leading to permanent pacemaker (PPM) implantation continue to be a complication after transcatheter aortic valve replacement (TAVR). OBJECTIVE The purpose of this study was to assess the prevalence of bradyarrhythmias using an electrocardiographic (ECG) extended rhythm recording in patients pre- and post-TAVR and whether they can predict the need for PPM. METHODS This was a prospective single-center study in patients undergoing TAVR. Patients received an ECG patch for 2 weeks pre-, immediately post-, and 2-3 months post-TAVR. Caring physicians were blinded to the results of the patch except when predefined urgent arrhythmias were detected. The main outcome was the need for PPM implantation after TAVR. RESULTS We enrolled 110 patients, of whom 96 underwent TAVR and were included in the final analysis. Bradyarrhythmias, defined as a pause of 3 seconds or more, occurred in 5.2%, 12.7%, and 7% of patients pre-, immediately post-, and 2-3 months post-TAVR, respectively. PPM implantation occurred in 12 patients (12.5%), of whom 9 (9.4%) underwent implantation during their index hospitalization while 3 (3.1%) required implantation postdischarge for indications other than heart block. No patients required PPM after receiving an ECG patch 2-3 months post-TAVR. Significant baseline predictors for the need for PPM included the presence of right bundle branch block and increased QRS duration. Bradyarrhythmias detected by the ECG patch did not predict the need for PPM at either the index hospitalization or the follow-up period. CONCLUSION Bradyarrhythmias are common and can be detected with extended ECG monitoring before and after TAVR; however, in our study they did not predict the need for PPM after TAVR (ClinicalTrials.gov identifier: NCT03180073).
Collapse
|
30
|
Clinical performance of implantable cardioverter-defibrillator lead monitoring diagnostics. Heart Rhythm 2021; 19:363-371. [PMID: 34767985 DOI: 10.1016/j.hrthm.2021.10.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 10/18/2021] [Accepted: 10/29/2021] [Indexed: 11/17/2022]
Abstract
BACKGROUND Implantable cardioverter-defibrillator (ICD) lead monitoring diagnostic alerts facilitate the diagnosis of structural lead failure. OBJECTIVE The purpose of this study was to prospectively study the performance of Medtronic ICD lead monitoring alerts. METHODS A prespecified ancillary substudy, World-Wide Randomized Antibiotic Envelope Infection Prevention Trial, was conducted in patients with an ICD with all available alerts enabled. The investigators reported possible lead system events (LSEs), with or without an alert. An independent committee reviewed all data and classified events as lead failure, other LSE, or nonlead system events (NLEs). RESULTS In 4942 patients who were followed for 19.4 ± 8.7 months, there were 124 alerts (65 LSEs, 59 NLEs) and 19 LSEs without an alert. Lead monitoring alerts had 100% sensitivity for the 48 adjudicated lead failures (95% confidence interval 92.6%-100%) and for 10 events adjudicated as either lead failure or connection issue. The positive predictive value of alerts for lead failure was 38.7% (48 of 124). For 34 pace-sense lead failures, an alert that incorporated oversensing was more sensitive than the pacing impedance threshold alert (33 patients [97.1%] vs 9 patients [26.5%]; P < .0001). However, the sensitivity was only 13.6% for lead dislodgments or perforations. Inappropriate shocks occurred in 2 patients with pace-sense lead failure (5.9%). No patient had unnecessary lead replacement for any of the NLEs. CONCLUSION In this first real-world prospective study, lead monitoring alerts had 100% sensitivity for identifying lead failures. Although their positive predictive value was modest, no false-positive alerts resulted in an unnecessary lead replacement. For the diagnosis of pace-sense lead failure, an alert for oversensing was more sensitive than a pacing impedance threshold alert. TRIAL REGISTRATION ClinicalTrials.gov identifier: NCT02277990.
Collapse
|
31
|
Novel ventricular tachyarrhythmia detection enhancement detects undertreated life-threatening arrhythmias. Heart Rhythm O2 2021; 3:70-78. [PMID: 35243438 PMCID: PMC8859789 DOI: 10.1016/j.hroo.2021.11.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
32
|
Risk Factors for CIED Infection After Secondary Procedures: Insights From the WRAP-IT Trial. JACC Clin Electrophysiol 2021; 8:101-111. [PMID: 34600848 DOI: 10.1016/j.jacep.2021.08.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/11/2021] [Accepted: 08/14/2021] [Indexed: 01/28/2023]
Abstract
OBJECTIVES This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures.
Collapse
|
33
|
Cardiac resynchronisation therapy in anthracycline-induced cardiomyopathy. Heart 2021; 108:274-278. [PMID: 34489312 DOI: 10.1136/heartjnl-2020-318333] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 03/31/2021] [Accepted: 04/04/2021] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Chemotherapy-induced cardiomyopathy has been increasingly recognised as patients are living longer with more effective treatments for their malignancies. Anthracyclines are known to cause left ventricular (LV) dysfunction. While heart failure medications are frequently used, some patients may need consideration for device-based therapies such as cardiac resynchronisation therapy (CRT). However, the role of CRT in anthracycline-induced cardiomyopathy (AIC) is not well understood. METHODS We performed a retrospective review of all patients undergoing CRT implantation at our centre from 2003 to 2019 with a diagnosis of AIC. The LV remodelling and survival outcomes of this population were obtained and then compared with consecutive patients with other aetiologies of non-ischaemic cardiomyopathy (NICM). RESULTS A total of 34 patients underwent CRT implantation with a diagnosis of AIC with a mean age of 60.5±12.7 years, left ventricular ejection fraction (LVEF) of 21.7%±7.4%, and 11.3±7.5 years and 10.2±7.4 years from cancer diagnosis and last anthracycline exposure, respectively. At 9.6±8.1 months after CRT implantation, there was an increase of LVEF from 21.8%±7.6% to 30.4%±13.0% (p<0.001). Patients whose LVEF increased by at least 10% post-CRT implant (42.5% of cohort) survived significantly longer than patients who failed to improve their LVEF by that amount (p=0.01). A propensity matched analysis between patients with AIC and 369 consecutive patients with other aetiologies of NICM who underwent CRT implantation during the same period revealed no significant differences in improvement in LVEF or long-term survival. CONCLUSIONS Patients with AIC undergo LV remodelling with CRT at rates similar to other aetiologies of NICM. Furthermore, AIC post-CRT responders have a favourable long-term mortality compared with non-responders.
Collapse
|
34
|
Antibiotic eluting envelopes: evidence, technology, and defining high-risk populations. Europace 2021; 23:iv28-iv32. [PMID: 34160597 PMCID: PMC8221048 DOI: 10.1093/europace/euab019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 01/08/2021] [Indexed: 12/20/2022] Open
Abstract
Cardiovascular implantable electronic devices (CIED) are effective and important components of modern cardiovascular care. Despite the dramatic improvements in the functionality and reliability of these devices, over time patients are at risk for developing several morbidities, the most feared of which are local and systemic infections. Despite significant financial investment and aggressive therapy with hospitalization, intravenous antibiotics, and transvenous lead extraction, the outcomes include a 1-year mortality rate as high as 25%. This risk of infection has increased over time, likely due to the increased complexity of the surgical interventions required to insert and replace these devices. The only way to reduce this morbidity and mortality is to prevent these infections, and other than preoperative antibiotics, there were little data supporting effective therapy until the WRAP-IT trial provided randomized data showing that pocket infections can be reduced by 60% at 12 months and major CIED infections reduced by 40% at 1 year with the use of the absorbable antibiotic eluting envelope in patient CIED procedures at high risk of infection. Not all CIED procedures are at high risk of infection and justify the use of the envelope, but cost-effectiveness data support the use of the antibiotic envelope particularly in patients with defibrillator replacements, revisions, and upgrades, such as to a resynchronization device and in patients with prior CIED infection, history of immunocompromise, two or more prior procedures, or a history of renal dysfunction.
Collapse
|
35
|
Lower rate limit for pacing by cardiac resynchronization defibrillators: Should lower rate programming be reconsidered? Heart Rhythm 2021; 18:2087-2093. [PMID: 34371194 DOI: 10.1016/j.hrthm.2021.07.068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/30/2021] [Accepted: 07/30/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND No real-world large database associates lower rate limit (LRL) programming and survival of subjects with cardiac resynchronization therapy-defibrillators (CRT-Ds). OBJECTIVE The purpose of this study was to test the hypothesis that lower LRL programming is independently associated with survival, and that LRL and heart rate score (HrSc) are associated. METHODS All dual-chamber CRT-D devices in the Remote Patient Monitoring (RPM) ALTITUDE database (2006-2011) were queried. Baseline HrSc was defined as the percentage of all atrial sensed and paced beats in the tallest 10-beat histogram bin postimplant. LRL was assessed during repeated RPM uploads. Using a Cox model multivariable analysis, relationships between LRL, survival, HrSc, and other variables were evaluated. Survival was determined by query of death indices. RESULTS Data analyzed included 61,881 subjects (mean follow-up 2.9 years). LRL ranged from 40 to 85 bpm. Baseline lower LRL was associated with younger age, less atrial fibrillation, female sex, and lower HrSc (P <.001 for all covariates). Lower LRL was associated with improved survival, with LRL 40 associated with the largest survival benefit. This was significant for all 3 HrSc subgroups (P <.001). An interaction between HrSc and LRL was observed, with the largest survival difference between HrSc groups observed at LRL-40 (P <.001). CONCLUSION LRL programming and HrSc were associated, and lower values of both were associated with improved survival in a large database of CRT-D subjects. Relationships between survival, LRL programming, and HrSc merit further study.
Collapse
|
36
|
B-PO01-034 CLINICAL PERFORMANCE OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD MONITORING FEATURES. Heart Rhythm 2021. [DOI: 10.1016/j.hrthm.2021.06.180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
37
|
Infectious consequences of hematoma from cardiac implantable electronic device procedures and the role of the antibiotic envelope: A WRAP-IT trial analysis. Heart Rhythm 2021; 18:2080-2086. [PMID: 34280568 DOI: 10.1016/j.hrthm.2021.07.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 07/07/2021] [Accepted: 07/11/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND Hematoma is a complication of cardiac implantable electronic device (CIED) procedures and may lead to device infection. The TYRX antibacterial envelope reduced major CIED infection by 40% in the randomized WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention Trial) study, but its effectiveness in the presence of hematoma is not well understood. OBJECTIVE The purpose of this study was to evaluate the incidence and infectious consequences of hematoma and the association between envelope use, hematomas, and major CIED infection among WRAP-IT patients. METHODS All 6800 study patients were included in this analysis (control 3429; envelope 3371). Hematomas occurring within 30 days postprocedure (acute) were characterized and grouped by study treatment and evaluated for subsequent infection risk. Data were analyzed using Cox proportional hazard regression modeling. RESULTS Acute hematoma incidence was 2.2% at 30 days, with no significant difference between treatment groups (envelope vs control hazard ratio [HR] 1.15; 95% confidence interval [CI] 0.84-1.58; P = .39). Through all follow-up, the risk of major infection was significantly higher among control patients with hematoma vs those without (13.1% vs 1.6%; HR 11.3; 95% CI 5.5-23.2; P <.001). The risk of major infection was significantly lower in the envelope vs control patients with hematoma (2.5% vs 13.1%; HR 0.18; 95% CI 0.04-0.85; P = .03). CONCLUSION The risk of hematoma was 2.2% among WRAP-IT patients. Among control patients, hematoma carried a >11-fold risk of developing a major CIED infection. This risk was significantly mitigated with antibacterial envelope use, with an 82% reduction in major CIED infection among envelope patients who developed hematoma compared to control.
Collapse
|
38
|
Cost-Effectiveness Analyses of an Absorbable Antibacterial Envelope for Use in Patients at Increased Risk of Cardiac Implantable Electronic Device Infection in Germany, Italy, and England. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2021; 24:930-938. [PMID: 34243836 DOI: 10.1016/j.jval.2020.12.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 12/02/2020] [Accepted: 12/14/2020] [Indexed: 06/13/2023]
Abstract
OBJECTIVES To model the cost-effectiveness of the TYRX Absorbable Antibacterial Envelope when used in patients at increased risk of cardiac implantable electronic device (CIED) infection in the context of 3 European healthcare systems: Germany, Italy, and England. METHODS A decision tree model with a lifetime horizon was populated using data from the Worldwide Randomized Antibiotic Envelope Infection Prevention Trial, a large multicenter randomized controlled trial. Use of the antibacterial envelope adjunctive to standard of care was compared to standard of care infection prevention alone. Patients in the model were divided into subgroups based on presence of factors known to increase infection risk. RESULTS The antibacterial envelope had the most favorable cost-effectiveness profile when patients had previously experienced CIED infection, had a history of immunosuppressive therapy, or had a Prevention of Arrhythmia Device Infection Trial (PADIT) score indicating high risk of infection (scores ≥6) at cost-effectiveness thresholds of €50 000 in Germany (assumed in the absence of an official threshold), €40 000 in Italy, and £30 000 in England. Probabilistic sensitivity analysis indicated that the antibacterial envelope was likely to be cost-effective in patients with other risk factors (including replacement of high power CIEDs, generator replacement with lead modification, and PADIT scores indicating intermediate risk of infection) when used with some device types and in some countries. CONCLUSIONS The absorbable antibacterial envelope was associated with cost-effectiveness ratios below European benchmarks in selected patients at increased risk of infection, suggesting the envelope provides value for European healthcare systems by reducing CIED infections.
Collapse
|
39
|
Infections associated with cardiac electronic implantable devices: economic perspectives and impact of the TYRX™ antibacterial envelope. Europace 2021; 23:iv33-iv44. [PMID: 34160600 PMCID: PMC8221050 DOI: 10.1093/europace/euab126] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 04/20/2021] [Indexed: 01/02/2023] Open
Abstract
The occurrence of cardiac implantable electronic devices (CIED) infections and related adverse outcomes have an important financial impact on the healthcare system, with hospitalization length of stay (2-3 weeks on average) being the largest cost driver, including the cost of device system extraction and device replacement accounting for more than half of total costs. In the recent literature, the economic profile of the TYRX™ absorbable antibacterial envelope was analysed taking into account both randomized and non-randomized trial data. Economic analysis found that the envelope is associated with cost-effectiveness ratios below USA and European benchmarks in selected patients at increased risk of infection. Therefore, the TYRX™ envelope, by effectively reducing CIED infections, provides value according to the criteria of affordability currently adopted by USA and European healthcare systems.
Collapse
|
40
|
Cardiac Resynchronization Therapy With or Without Defibrillation in Patients With Nonischemic Cardiomyopathy: A Systematic Review and Meta-Analysis. Circ Arrhythm Electrophysiol 2021; 14:e008991. [PMID: 33999647 DOI: 10.1161/circep.120.008991] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
[Figure: see text].
Collapse
|
41
|
In vitro modeling accurately predicts cardiac lead fracture at 10 years. Heart Rhythm 2021; 18:1605-1612. [PMID: 33992730 DOI: 10.1016/j.hrthm.2021.05.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 05/02/2021] [Accepted: 05/10/2021] [Indexed: 11/17/2022]
Abstract
BACKGROUND Development of a cardiac lead fracture model has the potential to differentiate well-performing lead designs from poor performing ones and could aid in future lead development. OBJECTIVE The purpose of this study was to demonstrate a predictive model for lead fracture and validate the results generated by the model by comparing them to observed 10-year implantable cardioverter-defibrillator lead fracture-free survival. METHODS The model presented here uses a combination of in vivo patient data, in vitro conductor fatigue test data, and statistical simulation to predict the fracture-free survival of cardiac leads. The model was validated by comparing the results to human clinical performance data from the Medtronic Sprint Fidelis (Minneapolis, MN) models 6931 (single coil, active fixation) and 6949 (dual coil, active fixation), as well as the Quattro model 6947 (dual coil, active fixation). RESULTS Median patient age in the single coil Fidelis 6931 population (64 years) was less than in the dual coil Fidelis 6949 and Quattro populations (68 years). Modeled and observed fracture-free survival for Quattro (>97%) was superior to that for Fidelis (<94%). The modeled survival agreed with the observed fracture-free survival data. The average model error was 0.3% (SD 1.2%). CONCLUSION This model for cardiac lead fracture-free survival using in vivo lead bending measurements and in vitro bench testing can be used to predict lead performance as observed by alignment with field survival data.
Collapse
|
42
|
Entrapped Leads After Transcatheter Tricuspid Valve Replacement. JACC Cardiovasc Interv 2021; 13:2815. [PMID: 33303121 DOI: 10.1016/j.jcin.2020.09.038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 09/22/2020] [Indexed: 10/22/2022]
|
43
|
Abstract
BACKGROUND Heart rate score (HrSc) ≥70% in cardiac resynchronization therapy defibrillator and implantable cardioverter-defibrillator subjects predicts 5-year mortality risk. A high HrSc suggests few sensed cardiac cycles above the programmed lower rate. OBJECTIVE To determine if HrSc is related to chronotropic incompetence (CI) in pacemaker (PM) subjects. METHODS HrSc is the percentage of all atrial-paced and sensed events in the single tallest 10 beats/min histogram bin programmed to DDD 60/min. The prospective LIFE study of PM subjects examined multiple treadmill-based measures of CI. The 1-month postimplant DDD 60/min PM rate histogram prior to treadmill was retrospectively analyzed for HrSc. Measures of CI were applied to submaximal treadmill data in the DDD mode. HrSc was compared to these CI measures and to clinical indications for PM. RESULTS The 1-month histogram demonstrated HrSc ≥70% in 43% of subjects. HrSc ≥70% correlated with a clinical diagnosis of sick sinus syndrome (P < .001). CI was present in 34%-88% of subjects by treadmill-based measures. Agreement between treadmill-based measures for CI was poor and varied from 39% to 83%. HrSc ≥70%, as a measure of CI, was most highly correlated with unpaced heart rate <70% of age-predicted maximum heart rate (67%) (odds ratio 3.7, P < .001). CONCLUSIONS HrSc ≥70% correlates with treadmill measures of CI and clinical sick sinus syndrome. HrSc ≥70% is a measure of CI in PM subjects that is inexpensive, repeatable, and quantitative.
Collapse
|
44
|
|
45
|
Exercise Ventricular Rates, Cardiopulmonary Exercise Performance, and Mortality in Patients With Heart Failure With Atrial Fibrillation. Circ Heart Fail 2021; 14:e007451. [PMID: 33478244 DOI: 10.1161/circheartfailure.120.007451] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
BACKGROUND In heart failure (HF) with sinus rhythm, resting and exercise heart rates correlate with exercise capacity and mortality. However, in HF with atrial fibrillation (AF), this correlation is unknown. Our aim is to investigate the association of resting and exercise ventricular rates (VRs) with exercise capacity and mortality in HF with AF. METHODS We identified 903 patients with HF and AF referred for cardiopulmonary stress testing. AF was defined as history of AF and AF during cardiopulmonary stress testing. We constructed multivariable models to evaluate the association of resting VR, peak exercise VR, VR reserve (peak VR-resting VR), and chronotropic index with (1) peak oxygen consumption (PVO2) ≤18 mL/kg per minute, (2) continuous PVO2, and (3) 10-year all-cause mortality. RESULTS Median (25th-75th percentile) age was 60 (52-67) years, left ventricular ejection fraction was 25 (15-50)%, and 76.1% were males. Patients with lower (quartile 1) compared with higher (quartile 4) peak VR, VR reserve, and chronotropic index were more likely to have PVO2 ≤18 mL/kg per min (adjusted odds ratio [95% CI]: 14.92 [8.07-27.58], 24.60 [12.36-48.98], and 22.31 [11.24-44.27], respectively), and higher all-cause mortality (adjusted hazard ratio [95% CI]: 2.56 [1.62-4.04], 2.29 [1.47-3.59], and 2.30 [1.51-3.49], respectively). For every 10 beats per minute increase in VR reserve, PVO2 increased by 1.05 mL/kg per minute (B-coefficient [95% CI]: 1.05 [0.94-1.15]) and mortality decreased by 12% (adjusted hazard ratio [95% CI]: 0.88 [0.83-0.94]). Resting VR was associated with PVO2 (B-coefficient [95% CI]: -0.46 [-0.70 to -0.23]) but not mortality (adjusted hazard ratio [95% CI]: 0.97 [0.88-1.06]). CONCLUSIONS In patients with HF and AF, higher resting VR and lower peak exercise VR, VR reserve, and chronotropic index were all associated with worse peak exercise capacity, but only lower exercise VR parameters were associated with higher mortality. Dedicated studies are needed to gauge whether modulating exercise VR enhances exercise performance and outcomes.
Collapse
|
46
|
Economic implications of adding a novel algorithm to optimize cardiac resynchronization therapy: rationale and design of economic analysis for the AdaptResponse trial. J Med Econ 2020; 23:1401-1408. [PMID: 33043737 DOI: 10.1080/13696998.2020.1835333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
AIMS Although cardiac resynchronization therapy (CRT) has proven beneficial in several randomized trials, a subset of patients have limited clinical improvement. The AdaptivCRT algorithm provides automated selection between synchronized left ventricular or biventricular pacing with optimization of atrioventricular delays. The rationale and design of the economic analysis of the AdaptResponse clinical trial are described. RATIONALE The costs associated with HF hospitalization are substantial and are compounded by a high rate of readmission. HF hospitalization payments range from $1,001 for Greece to $12,235 for US private insurance. When examining the breakdown of HF-related costs, it is clear that approximately 55% of the hospitalization costs are directly attributable to length of stay. Notably, the mean costs of a CRT patient in need of a HF-related hospitalization are currently estimated to be an average of $10,679. METHODS The economic analysis of the AdaptResponse trial has two main objectives. The hospital provider objective seeks to test the hypothesis that AdaptivCRT reduces the incidence of all-cause re-admissions after a heart failure admission within 30 days of the index event. A negative binomial regression model will be used to estimate and compare the number of readmissions after an index HF hospitalization. The payer economic objective will assess cost-effectiveness of CRT devices with the AdaptivCRT algorithm relative to traditional CRT programming. This analysis will be conducted from a U.S. payer perspective. A decision analytic model comprised of a 6-month decision tree and a Markov model for long term extrapolation will be used to evaluate lifetime costs and benefits. CONCLUSION AdaptivCRT may offer improvements over traditional device programming in patient outcomes. How the data from AdaptResponse will be used to demonstrate if these clinical benefits translate into substantial economic gains is herein described.
Collapse
|
47
|
Clinical Presentation, Timing, and Microbiology of CIED Infections: An Analysis of the WRAP-IT Trial. JACC Clin Electrophysiol 2020; 7:50-61. [PMID: 33478712 DOI: 10.1016/j.jacep.2020.07.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/14/2020] [Accepted: 07/29/2020] [Indexed: 12/15/2022]
Abstract
OBJECTIVES This study characterized the microbiology of major cardiac implantable electronic device (CIED) infections that occurred during the WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) study. BACKGROUND The WRAP-IT study offers a unique opportunity for further understanding of the pathogens involved in major CIED infections in a prospective dataset, with implications for clinical practice and infection management. METHODS A total of 6,800 patients randomized 1:1 to receive an antibacterial envelope or not (control subjects) were included in this analysis. Patient characteristics, infection manifestation (pocket vs. systemic), and infection microbiology were evaluated through all follow-up (36 months). Data were analyzed using Cox proportional hazards regression. RESULTS A total of 3,371 patients received an envelope, and 3,429 patients were control subjects. Major CIED infection occurred in 32 patients who received an envelope and 51 control subjects (36-month Kaplan-Meier estimated event rate, 1.3% and 1.9%, respectively; p = 0.046). A 61% reduction in major pocket infection was observed within 12 months of the procedure in the envelope group (hazard ratio: 0.39, 95% confidence interval: 0.21 to 0.73; p = 0.003). Among 76 patients with major infections who had a sample taken, causative pathogens were identified in 47 patients. Staphylococcus species were the predominate pathogen (n = 31) and envelope use resulted in a 76% reduction in Staphylococcus-related pocket infections (n = 4 vs. 17; p = 0.010). Envelope use was not associated with delayed onset of pocket infections and did not affect the presentation of infections. CONCLUSIONS Antibacterial envelope use resulted in a significant reduction of major CIED pocket infections and was particularly effective against Staphylococcus species, the predominant cause of pocket infections. (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial [WRAP-IT]; NCT02277990).
Collapse
|
48
|
Long-Term Outcomes in Patients With a Left Ejection Fraction ≤15% Undergoing Cardiac Resynchronization Therapy. JACC Clin Electrophysiol 2020; 7:36-46. [PMID: 33478710 DOI: 10.1016/j.jacep.2020.07.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 07/27/2020] [Accepted: 07/27/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES This study aimed to determine the long-term outcomes and predictors of left ventricular (LV) ejection fraction (LVEF) improvement in patients with severe cardiomyopathies undergoing cardiac resynchronization therapy (CRT). BACKGROUND Whether patients with severe LV dysfunction benefit from CRT or have reached a point in disease severity past the point at which CRT is beneficial is unknown. METHODS We collected clinical and echocardiographic data on 420 patients with an LVEF of ≤15% and a QRS duration of ≥120 ms undergoing CRT at the Cleveland Clinic and 2 hospitals in the Johns Hopkins Health System between April 2003 and May 2014. Multivariate models were created to determine factors associated with response to CRT, defined as an absolute improvement in LVEF of >5% and survival free of LVAD and heart transplant. Procedure-related deaths were also collected. RESULTS A total of 298 patients had pre- and appropriately timed post-CRT echocardiograms, of whom 145 (48.7%) met the criteria for response. In multivariate analysis, LV size and left bundle branch block (LBBB) were associated with response. Among the most dilated quintile (LV end-diastolic diameter [LVEDD] of >7.8 cm), 30.4% met the criteria for response. In multivariate analysis, smaller LV end-diastolic dysfunction and presence of LBBB were associated with improved survival free of heart failure and LVAD over a mean follow-up period of 5.2 years. There were no procedure-related deaths. CONCLUSIONS Patients with severe LV dysfunction respond to CRT, although at a lower rate compared to traditional CRT candidates. Smaller LV size and LBBB are important predictors of positive outcomes in this population. Even among the most dilated patients, 30.4% realized a meaningful improvement in LVEF with CRT. The CRT implant procedure itself appears well tolerated.
Collapse
|
49
|
Obesity Predicts Survival After Cardiac Resynchronization Therapy Independent of Effect on Left Ventricular Ejection Fraction. Circ Heart Fail 2020; 13:e007424. [PMID: 33054346 DOI: 10.1161/circheartfailure.120.007424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
50
|
Cost-Effectiveness of an Antibacterial Envelope for Cardiac Implantable Electronic Device Infection Prevention in the US Healthcare System From the WRAP-IT Trial. Circ Arrhythm Electrophysiol 2020; 13:e008503. [PMID: 32915063 PMCID: PMC7566304 DOI: 10.1161/circep.120.008503] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Supplemental Digital Content is available in the text. In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system.
Collapse
|