1
|
Evolution of the throwing shoulder: why apes don't throw well and how that applies to throwing athletes. J Shoulder Elbow Surg 2024; 33:1404-1417. [PMID: 38316235 DOI: 10.1016/j.jse.2023.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 12/04/2023] [Accepted: 12/17/2023] [Indexed: 02/07/2024]
Abstract
BACKGROUND Humans have unique characteristics making us the only primate that can throw well while most other primates throw predominately underhand with poor speed and accuracy. The purpose of this study is to illuminate the uniquely human characteristics that allow us to throw so well. When treating an injury such as a labral tear or capsule tear, this study hopes the reader can gain a better understanding of the issues that lead to the tear and those that may determine the success of treatment besides the actual repair. METHODS In addition to a review of scientific and medical literature, information was obtained from interviews and experience with primate veterinarians, anthropologists, archeologists, and professional baseball players. These sources were used to study the connection between evolutionary throwing activities and current sports medicine issues. RESULTS Arm acceleration requires a functional kinetic chain, rapid motor sequences, and the ability to absorb elastic energy in the shoulder. Successful treatment of the throwing shoulder requires awareness of the shoulder's position in the kinetic chain and correction of defects in the ability to execute the kinetic chain. Some problems in the shoulder could reflect regression to a more primitive anatomy or dyskinesis. Return of performance requires regaining the elasticity in the tissues of the shoulder to temporarily store kinetic energy. For example, tissue remodeling after rotator cuff repair continues for months to years; however, the newly formed tissue lacks the same elasticity of the native tendon. This suggests why throwing performance typically does not return for 7 or more months after repair even though there may be structural integrity at 3-4 months. CONCLUSION The shoulder has developed uniquely in modern man for the act of throwing. The anatomic deficiencies in primates for throwing provide an illustration of the more subtle changes that a throwing athlete might have that are detrimental to throwing. Nonhuman primates have been unable to demonstrate the kinetic chain sequence for throwing secondary to the lack of neurologic pathways required. Humans are more sophisticated and precise in their movements but lack robusticity in their bone and muscle architecture, seen especially in the human rotator cuff. Successful treatment of a throwing injury requires familiarity with the conditions that cause the injury or affect the rehabilitation process. The return of performance following injury or surgery requires regaining the elasticity in the tissues of the shoulder to temporarily store kinetic energy from the kinetic chain.
Collapse
|
2
|
A Network Meta-Analysis of Randomized Controlled Trials Assessing Intraoperative Anesthetic Therapies for Analgesic Efficacy and Morphine Consumption Following Total Knee Arthroplasty. J Arthroplasty 2024; 39:1361-1373. [PMID: 37952743 DOI: 10.1016/j.arth.2023.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/03/2023] [Accepted: 11/07/2023] [Indexed: 11/14/2023] Open
Abstract
BACKGROUND The purpose of this study was to compare intraoperative anesthetic therapies for total knee arthroplasty (TKA) regarding postoperative analgesic efficacy and morphine consumption by conducting a systematic literature search. METHODS Randomized controlled trials of TKA using various anesthetic therapies were identified from various databases from conception through December 31, 2021. A network meta-analysis of relevant literature was performed to investigate which treatment showed better outcomes. In total, 40 trials were included in this study. RESULTS Surface under the cumulative ranking curve showed local infiltration anesthesia (LIA) with saphenous nerve block (SNB) to produce the best pain relief on postoperative days (PODs) 1 and 2 and the best reduction of morphine consumption on PODs 1 and 3. However, femoral nerve block showed the largest effect on pain relief on POD 3, and liposomal bupivacaine showed the largest effect on reduction of morphine consumption on POD 2. CONCLUSIONS According to this network meta-analysis, surface under the cumulative ranking curve percentage showed that LIA with SNB provided the best analgesic effect after TKA. Furthermore, patients receiving LIA with SNB had the lowest consumption of morphine. Although femoral nerve block resulted in better pain relief on POD 3, LIA with SNB could be selected first when trying to reduce morphine consumption or increase early ambulation.
Collapse
|
3
|
Effect of Meniscal Tear Patterns and Preoperative Cartilage Status on Joint Space Width After Medial Opening-Wedge High Tibial Osteotomy. Am J Sports Med 2024; 52:1535-1542. [PMID: 38623875 DOI: 10.1177/03635465241239327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
BACKGROUND Medial opening-wedge high tibial osteotomy (MOWHTO) is performed to treat young adults with medial compartment knee osteoarthritis associated with varus deformity. However, factors influencing joint space width (JSW) vary according to the type of medial meniscal tear and have not yet been completely elucidated. PURPOSE To examine changes in JSW according to the type of medial meniscal tear after MOWHTO and analyze the influencing factors. STUDY DESIGN Cohort study; Level of evidence, 3. METHODS This study was conducted on 134 patients who underwent MOWHTO for medial osteoarthritis and were followed up for >2 years. The patients were classified into 3 groups based on medial meniscal status: intact, nonroot tear, and root tear. The authors then measured the JSW preoperatively and at 3 months, 6 months, 1 year, and >2 years postoperatively; analyzed whether the change in JSW varied according to meniscal status; and determined the association of these changes with the preoperative cartilage grade of the medial femoral condyle (MFC) and medial tibial plateau (MTP). International Knee Documentation Committee (IKDC) scores were used to evaluate clinical function. RESULTS Of the 134 patients, the medial meniscus was intact in 29 patients, a nonroot tear was observed in 58 patients, and a root tear was observed in 47 patients. Postoperatively, JSW increased for all groups, but the timing of the increase varied between the groups (P < .001). JSW increased the most 6 months postoperatively in the intact group and 3 months postoperatively in the nonroot tear and root tear groups (P < .001). Additionally, the increase in JSW was the greatest in the root tear group. Preoperatively, MFC and MTP cartilage status differed among the groups; MTP status did not affect the JSW, but MFC status did (P < .001). The IKDC score increased from the preoperative to postoperative time point in all groups, but there was no significant difference between groups. CONCLUSION The authors observed that the amount and timing of increase in JSW were dependent on the pattern of medial meniscal tear observed when MOWHTO was performed. In addition, the cartilage grade of MFC before surgery was associated with changes in JSW. The IKDC score was not significantly different between groups. However, a longer follow-up period is needed to analyze the correlation with the meniscal tear pattern and JSW.
Collapse
|
4
|
In Vivo Kinematics and Cruciate Ligament Tension Are Not Restored to Normal After Bicruciate-Preserving Arthroplasty. J Arthroplasty 2024:S0883-5403(24)00300-0. [PMID: 38552864 DOI: 10.1016/j.arth.2024.03.060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 03/19/2024] [Accepted: 03/21/2024] [Indexed: 04/23/2024] Open
Abstract
BACKGROUND Whether cruciate ligament forces in cruciate-preserving designs, such as unicompartmental knee arthroplasty (UKA) or bi-cruciate-retaining total knee arthroplasty (BCR-TKA), differ from those in normal knees remains unknown. The purpose of this study was to compare the in vivo kinematics and cruciate ligament force in knees before and after UKA or BCR-TKA to those in normal knees during high-flexion activity. METHODS Overall, twenty normal knees, 17 knees with medial UKA, and 15 knees with BCR-TKA were fluoroscopically examined while performing a squatting activity. A 2-dimensional or 3-dimensional registration technique was employed to measure tibio-femoral kinematics. Ligament strains and tensions in the anteromedial bundle of the anterior cruciate ligament and posterolateral bundle of the anterior cruciate ligament and the anterolateral bundle of the posterior cruciate ligament (aPCL) and posteromedial bundle of the posterior cruciate ligament (pPCL) during knee flexion were analyzed. RESULTS Tension in both bundles of the anterior cruciate ligament decreased with flexion. At 60° of flexion, anteromedial bundle of the anterior cruciate ligament tension in postoperative UKA knees was greater than that in normal knees. At 30° of flexion, posterolateral bundle of the anterior cruciate ligament tension in postoperative UKA knees was greater than that in normal knees. On the other hand, aPCL and pPCL tensions increased with flexion. From 40 to 110° of flexion, the postoperative aPCL tension in UKA knees was greater than that in normal knees. At 110° of flexion, the preoperative pPCL tension in UKA knees was greater than that in normal knees. In addition, the postoperative pPCL tension in UKA knees was larger than that in normal knees beyond 20° of flexion. Furthermore, the pPCL tension of postoperative BCR-TKA knees was larger than that in normal knees from 20 to 50° and beyond 90° of flexion. CONCLUSIONS The cruciate ligament tensions, especially posterior cruciate ligament tension in knees after UKA, were greater than those in the normal knees. Surgeons performing bi-cruciat-preserving knee arthroplasties should therefore balance cruciate ligament tension more carefully in flexion and extension.
Collapse
|
5
|
Repair of medial meniscus posterior root tear is effective for root healing and cartilage regeneration in opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 2023; 31:5799-5811. [PMID: 37940662 DOI: 10.1007/s00167-023-07637-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Accepted: 10/13/2023] [Indexed: 11/10/2023]
Abstract
PURPOSE This study aimed to determine whether the repair of a medial meniscus posterior root tear (MMPRT) is effective for MMPRT healing, cartilage regeneration, and clinical outcomes in opening wedge high tibial osteotomy (OWHTO). METHODS This retrospective study included 80 patients who underwent OWHTO and subsequent second-look arthroscopy. The patients were divided into OWHTO-with-MMPRT-repair (n = 40) and OWHTO alone (n = 40) groups, and the healing rates (complete/partial/failure) were compared. Each group was further divided into over- and under-corrected subgroups to compare healing rates. The International Cartilage Repair Society (ICRS) grade, cartilage defect size, Koshino stage, ICRS cartilage repair assessment score of the medial femoral condyle (MFC), and International Knee Documentation Committee (IKDC) scores between the OWHTO-with-MMPRT-repair and OWHTO alone groups were compared according to whether microfracture was performed on the MFC. RESULTS The overall healing rate of the MMPRT was higher in the OWHTO-with-MMPRT-repair group than that in the OWHTO alone group (P < 0.001). In addition, in the subgroup analysis, no difference in the MMPRT healing rate between the over-correction and under-correction groups when MMPRT repair was performed (n.s). In contrast, without MMPRT repair, the healing rate was lower in the under-correction group than that in the over-correction group (P = 0.03). Cartilage regeneration of the OWHTO-with-MMPRT-repair group was superior to that of the OWHTO alone group (P < 0.05). The IKDC subjective scores of the OWHTO-with-MMPRT-repair and OWHTO alone groups were 34.5 and 33.1 before surgery (n.s) and 50 and 47.2 at one year after surgery, respectively (n.s). These differences between the two groups for cartilage regeneration and IKDC subjective scores showed the same pattern regardless of microfractures. CONCLUSIONS MMPRT repair during OWHTO might improve MMPRT healing, even with under-correction, and cartilage regeneration of MFC, regardless of microfracture. However, OWHTO with MMPRT repair might not improve short-term clinical outcomes compared to OWHTO alone. Further randomized clinical trials are necessary. LEVEL OF EVIDENCE III, Retrospective cohort study.
Collapse
|
6
|
Bicruciate-retaining total knee arthroplasty procedure reduced tensile force in the middle and posterior components of lateral collateral ligament during deep knee flexion activities with no effect on tensile force of the medial collateral ligament. Knee Surg Sports Traumatol Arthrosc 2023; 31:3889-3897. [PMID: 36928366 DOI: 10.1007/s00167-023-07342-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 02/05/2023] [Indexed: 03/18/2023]
Abstract
PURPOSE To analyse the effects of bicruciate-retaining total knee arthroplasty (BCR-TKA) on the tensile force of the collateral ligaments during two deep knee flexion activities, cross-leg sitting and squatting. METHODS Thirteen patients (15 knees) treated using bicruciate-retaining total knee arthroplasty (BCR-TKA) for knee joint osteoarthritis were analysed. Knee joint kinematics during cross-leg sitting (open-chain flexion) and squatting (closed-chain flexion) were evaluated through fluoroscopy. The tensile force was calculated in vivo based on the change in the distance between the femoral and tibial attachment areas for the anterior, middle, and posterior components of the superficial (sMCL) and deep (dMCL) medial collateral ligament and the lateral collateral ligament (LCL). Differences in the calculated tensile forces of the collateral ligaments were evaluated using repeated measures of analysis of variance, with post hoc pairwise comparison (Bonferroni test). Statistical significance was set at P ≤ 0.05. RESULTS The correction of the coronal alignment was related to the surgical technique, not to the implant design. No significant change in the tensile force in all three components of the sMCL from pre- to post-TKA (n.s.) was observed. For dMCL, a pre- to post-TKA change in the tensile force was observed only for the anterior dMCL component (p = 0.03). No change was observed in the tensile force of the anterior LCL with increasing flexion, with no difference in pre- to post-TKA and between activities (n.s.). In contrast, tensile force in the middle LCL slightly decreased with increasing flexion during squatting, pre- and post-TKA. After surgery, lower forces were generated at 40° of flexion (p = 0.04). Tensile force in the posterior LCL was higher in extension than flexion, which remained high in the extension post-TKA. However, after surgery, lower tensile forces were generated at 10° (p = 0.04) and 40° (p = 0.04) of flexion. CONCLUSIONS The in vivo change in tensile forces of the collateral ligaments of the knee before and after BCR-TKA can inform the development of appropriate ligament balancing strategies to facilitate recovery of deep knee flexion activities after TKA, as well as for continued improvement of BCR-TKA designs. LEVEL OF EVIDENCE III.
Collapse
|
7
|
ALK-5 Inhibitors for Efficient Derivation of Mesenchymal Stem Cells from Human Embryonic Stem Cells. Tissue Eng Part A 2023; 29:127-140. [PMID: 36458467 DOI: 10.1089/ten.tea.2022.0164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Objectives: Successful tissue regeneration requires a clinically viable source of mesenchymal stem cells (MSCs). We explored activin receptor-like kinase (ALK)-5 inhibitors to rapidly derive an MSC-like phenotype with high cartilage forming capacity from a xeno-free human embryonic cell line. Methods: Embryonic stem cell (ESC) lines (H9 and HADC100) were treated with the ALK-5 inhibitor SB431542; HADC100 cells were additionally treated with ALK-5 inhibitors SB525334 or GW788388. Cells were then seeded upon human fibronectin in the presence of fibroblast growth factor 2 (FGF2) in a serum-free medium. Flow cytometry was used to assess MSC markers (positive for CD73, CD90, and CD105; negative for CD34 and CD45). Differentiation status was assessed through quantitative polymerase chain reaction. Cartilage forming capacity was determined in high-density pellet cultures, in fibrin gels containing extracellular matrix (fibrin-ECM), and after implantation in ex vivo human osteoarthritic cartilage. Gene expression, histology, and immunostaining were used to assess cartilage phenotype, tissue regeneration, and integration. Results: Exposure to all three ALK-5 inhibitors lead to expression of mesodermal gene markers and differentiation into MSC-like cells (embryonic stem cell-derived mesenchymal stem cells [ES-MSCs]) based on surface marker expression. ES-MSC in pellet cultures or in fibrin-ECM gels expressed high levels of chondrogenic genes: COL2A1, ACAN, and COMP; and low levels of COL1A1 and RUNX2. Cell pellets or fibrin constructs implanted into ex vivo human osteoarthritic cartilage defects produced GAG-rich (safranin O positive) and collagen type II-positive neocartilage tissues that integrated well with native diseased tissue. Conclusions: We developed a protocol for rapid differentiation of xeno-free ESC into MSC-like cells with high cartilage forming capacity with potential for clinical applications. Impact statement Osteoarthritis (OA) is a common disease resulting in significant disability and no approved disease modifying treatment (other than total joint replacement). Embryonic stem cell-derived cell therapy has the potential to benefit patients with cartilage lesions leading to OA and may prevent or delay the need for total joint replacement.
Collapse
|
8
|
Senescent cell population with ZEB1 transcription factor as its main regulator promotes osteoarthritis in cartilage and meniscus. Ann Rheum Dis 2023; 82:403-415. [PMID: 36564153 PMCID: PMC10076001 DOI: 10.1136/ard-2022-223227] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 11/08/2022] [Indexed: 12/25/2022]
Abstract
OBJECTIVES Single-cell level analysis of articular cartilage and meniscus tissues from human healthy and osteoarthritis (OA) knees. METHODS Single-cell RNA sequencing (scRNA-seq) analyses were performed on articular cartilage and meniscus tissues from healthy (n=6, n=7) and OA (n=6, n=6) knees. Expression of genes of interest was validated using immunohistochemistry and RNA-seq and function was analysed by gene overexpression and depletion. RESULTS scRNA-seq analyses of human knee articular cartilage (70 972 cells) and meniscus (78 017 cells) identified a pathogenic subset that is shared between both tissues. This cell population is expanded in OA and has strong OA and senescence gene signatures. Further, this subset has critical roles in extracellular matrix (ECM) and tenascin signalling and is the dominant sender of signals to all other cartilage and meniscus clusters and a receiver of TGFβ signalling. Fibroblast activating protein (FAP) is also a dysregulated gene in this cluster and promotes ECM degradation. Regulons that are controlled by transcription factor ZEB1 are shared between the pathogenic subset in articular cartilage and meniscus. In meniscus and cartilage cells, FAP and ZEB1 promote expression of genes that contribute to OA pathogenesis, including senescence. CONCLUSIONS These single-cell studies identified a senescent pathogenic cell cluster that is present in cartilage and meniscus and has FAP and ZEB1 as main regulators which are novel and promising therapeutic targets for OA-associated pathways in both tissues.
Collapse
|
9
|
Tibial sagittal and rotational alignment reduce patellofemoral stresses in posterior stabilized total knee arthroplasty. Sci Rep 2022; 12:12319. [PMID: 35854017 PMCID: PMC9296446 DOI: 10.1038/s41598-022-15759-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 06/29/2022] [Indexed: 11/09/2022] Open
Abstract
Patellofemoral joint complications remain an important issue in total knee arthroplasty. We compared the patellofemoral contact status between cruciate-retaining and posterior-stabilized designs with varying degrees of tibial sagittal and rotational alignment using a computer simulation to ensure proper alignments in total knee arthroplasty. Knee kinematics, patellofemoral contact force and quadriceps force were computed using a musculoskeletal modeling program (LifeMOD/KneeSIM 2010; LifeModeler, Inc., San Clemente, California) during a weight-bearing deep knee bend. Two different posterior tibial slope (PTS)s (3° and 7°) and five different tibial tray rotational alignments (neutral, internal 5° and 10°, and external 5° and 10°) were simulated. Patellofemoral contact area and stresses were next computed using finite element analysis. The patellofemoral contact force for the posterior-stabilized design was substantially lower than the cruciate-retaining design after post-cam contact because of increasing femoral roll-back. Neutral rotational alignment of the tibial component resulted in smaller differences in patellofemoral contact stresses between cruciate-retaining and posterior-stabilized designs for PTSs of 3° or 7°. However, the patellar contact stresses in the cruciate-retaining design were greater than those in posterior-stabilized design at 120° of knee flexion with PTS of 3° combined with internal rotation of the tibial component. Our study provides biomechanical evidence implicating lower PTSs combined with internal malrotation of the tibial component and the resultant increase in patellofemoral stresses as a potential source of anterior knee pain in cruciate-retaining design.
Collapse
|
10
|
Intraoperative knee kinematics measured by computer-assisted navigation and intraoperative ligament balance have the potential to predict postoperative knee kinematics. J Orthop Res 2022; 40:1538-1546. [PMID: 34559437 DOI: 10.1002/jor.25182] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 08/28/2021] [Accepted: 09/07/2021] [Indexed: 02/04/2023]
Abstract
This study was designed to analyze the effects of type of activity and cruciate ligament resection on knee kinematics and ligament balance after total knee arthroplasty (TKA), and to determine if intraoperative passive kinematics are associated with active kinematics. Fresh-frozen human cadaveric knees were examined. The knees were mounted on a quadriceps-driven simulator. Cruciate-retaining (CR-TKA) and posterior-substituting (PS-TKA) TKA was performed using a contemporary knee system. Active flexion (closed-kinetic chain [CKC] and open-kinetic-chain [OKC]) and passive flexion were analyzed by recording the knee kinematics using a specifically developed application of an imageless navigation system. An electronic ligament balancer was used to measure the tibiofemoral gap under constant distraction pressure. The femur rotated externally relative to the tibia during passive and active CKC flexion. The femur translated anteriorly from 10° to 50° of flexion after TKA. Beyond 50° of flexion, the femur translated posteriorly in all surgical conditions. The femoral location during active CKC flexion was posterior relative to that during active OKC. Femoral rotation and translation during passive knee flexion correlated significantly with that during active knee flexion. Posterior tilt of the electronic ligament balancer was greater with CR-TKA than with PS-TKA and correlated significantly with the anteroposterior position of the femur. Statement of Clinical Significance: Intraoperative knee kinematics measured by computer-assisted navigation and intraoperative ligament balance have the potential to predict postoperative knee kinematics.
Collapse
|
11
|
Postoperative Valgus Laxity and Medial Pivot Kinematics Are Significantly Associated With Better Clinical Outcomes. J Arthroplasty 2022; 37:S187-S192. [PMID: 35231562 DOI: 10.1016/j.arth.2022.02.088] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 02/15/2022] [Accepted: 02/18/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The relative impact of soft tissue balance and knee laxity on clinical outcomes after total knee arthroplasty (TKA) is not fully understood. We analyzed associations among knee laxity, kinematics, and patient-reported outcomes. METHODS Knee Society Scores were recorded in 67 patients before and after primary TKA for osteoarthritis with varus deformity (N = 78). Varus and valgus laxity was measured in 78 knees using stress radiographs. Knee kinematics were measured fluoroscopically during stair ascent in 16 knees. RESULTS On average, varus laxity decreased significantly, and valgus laxity increased significantly after TKA, although the net combined varus-valgus laxity did not change significantly. Postoperatively, the magnitude of valgus laxity correlated significantly with greater patient symptoms and satisfaction scores. Patients with medial pivot kinematics scored higher on patient satisfaction and standard activities. CONCLUSION We found that postoperative valgus laxity and medial pivot kinematics were significantly associated with better clinical outcomes. These results emphasize the importance of careful preoperative planning and attention to intraoperative alignment and ligament balancing.
Collapse
|
12
|
Collagen fibrous scaffolds for sustained delivery of growth factors for meniscal tissue engineering. Nanomedicine (Lond) 2022; 17:77-93. [PMID: 34991339 PMCID: PMC8765117 DOI: 10.2217/nnm-2021-0313] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Aim: To mimic the ultrastructural morphology of the meniscus with nanofiber scaffolds coupled with controlled growth factor delivery to modulate cellular performance for tissue engineering of menisci. Methods: The authors functionalized collagen nanofibers by conjugating heparin to the following growth factors for sustained release: PDGF-BB, TGF-β1 and CTGF. Results: Incorporating growth factors increased human meniscal and synovial cell viability, proliferation and infiltration in vitro, ex vivo and in vivo; upregulated key genes involved in meniscal extracellular matrix synthesis and enhanced generation of meniscus-like tissue. Conclusion: The authors' results indicate that functionalizing collagen nanofibers can create a cell-favorable micro- and nanoenvironment and can serve as a system for sustained release of bioactive factors.
Collapse
|
13
|
Subcutaneous toxicity of a dual ionically cross-linked atelocollagen and sodium hyaluronate gel: Rat in vivo study for biological safety evaluation of the injectable hydrogel. Toxicol Rep 2021; 8:1651-1656. [PMID: 34567979 PMCID: PMC8449164 DOI: 10.1016/j.toxrep.2021.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 08/29/2021] [Accepted: 09/12/2021] [Indexed: 11/30/2022] Open
Abstract
Hydrogel wound dressings are commonly used to stop bleeding and enhance healing. Hyaluronic acid and collagen are beneficial for wound healing, however, each polymer has limitations. A dual hydrogel combining the benefits of both biopolymers can be more effective for the treatment of various wound types. A composite of collagen and sodium hyaluronate did not generate significant subacute toxicity or reactivity in vivo.
Hydrogels are commonly used in wound dressing, as they retain moisture, accelerate healing, and break down necrotic tissue. This process enhances patient comfort levels while simultaneously reducing pain caused by dead tissue. The purpose of this study was to investigate the in vivo toxicity of a dual hydrogel consisting of type I atelocollagen cross-linked with sodium hyaluronate hydrogel used for wound dressing. Porcine type I atelocollagen was cross-linked with sodium hyaluronate to form the hydrogel. For subcutaneous implantation, 0.5 ml of dual hydrogel was injected into two different sites of twenty rats per group. High density polyethylene rods were implanted subcutaneously to serve as a control material. Hematological assessment, blood biochemistry, histopathological, and histological evaluations were scored and graded after 4 weeks. A bioreactivity rating was used for evaluation of subacute toxicity. Differences observed in blood chemical analysis and hematological analysis between control and test groups were within normal variations and considered unrelated to the test article implantation. No significant implantation-related lesions were observed in any of the major organs of all test animals. The overall histopathological index of the test article implantation sites was evaluated as 0. The bioreactivity rating was evaluated as non-irritant after 4-week subcutaneous implantation. Overall, these results indicate that the dual hydrogel of type I atelocollagen and sodium hyaluronate is biologically and chemically safe for clinical application as a wound dressing.
Collapse
|
14
|
Cruciate ligament force of knees following mobile-bearing unicompartmental knee arthroplasty is larger than the preoperative value. Sci Rep 2021; 11:18233. [PMID: 34521921 PMCID: PMC8440682 DOI: 10.1038/s41598-021-97655-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 08/20/2021] [Indexed: 11/29/2022] Open
Abstract
We analyzed the implantation effects on cruciate ligament force in unicompartmental knee arthroplasty (UKA) and determined whether kinematics is associated with the cruciate ligament force. We examined 16 patients (17 knees) undergoing medial UKA. Under fluoroscopy, each participant performed a deep knee bend before and after UKA. A two-dimensional/three-dimensional registration technique was employed to measure tibiofemoral kinematics. Forces in the anteromedial and posterolateral bundles of both the anterior cruciate ligament (aACL and pACL) and the anterolateral and posteromedial bundles of the posterior cruciate ligament (aPCL and pPCL) during knee flexion were analyzed pre- and post-UKA. Correlations between changes in kinematics and ligament forces post-UKA were also analyzed. Preoperatively, the aACL forces were highly correlated with anteroposterior (AP) translation of the lateral condyles (Correlation coefficient [r] = 0.59). The pPCL forces were highly correlated with the varus–valgus angulation (r = − 0.57). However, postoperatively, the PCL forces in both bundles were highly correlated with the AP translation of the medial femoral condyle (aPCL: r = 0.62, pPCL: r = 0.60). The ACL and PCL forces of the knees post-UKA were larger than those of the knees pre-UKA. Kinematic changes were significantly correlated with the cruciate ligament force changes.
Collapse
|
15
|
Mohawk is a transcription factor that promotes meniscus cell phenotype and tissue repair and reduces osteoarthritis severity. Sci Transl Med 2021; 12:12/567/eaan7967. [PMID: 33115953 DOI: 10.1126/scitranslmed.aan7967] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 02/06/2020] [Accepted: 09/21/2020] [Indexed: 12/13/2022]
Abstract
Meniscus tears are common knee injuries and a major osteoarthritis (OA) risk factor. Knowledge gaps that limit the development of therapies for meniscus injury and degeneration concern transcription factors that control the meniscus cell phenotype. Analysis of RNA sequencing data from 37 human tissues in the Genotype-Tissue Expression database and RNA sequencing data from meniscus and articular cartilage showed that transcription factor Mohawk (MKX) is highly enriched in meniscus. In human meniscus cells, MKX regulates the expression of meniscus marker genes, OA-related genes, and other transcription factors, including Scleraxis (SCX), SRY Box 5 (SOX5), and Runt domain-related transcription factor 2 (RUNX2). In mesenchymal stem cells (MSCs), the combination of adenoviral MKX (Ad-MKX) and transforming growth factor-β3 (TGF-β3) induced a meniscus cell phenotype. When Ad-MKX-transduced MSCs were seeded on TGF-β3-conjugated decellularized meniscus scaffold (DMS) and inserted into experimental tears in meniscus explants, they increased glycosaminoglycan content, extracellular matrix interconnectivity, cell infiltration into the DMS, and improved biomechanical properties. Ad-MKX injection into mouse knee joints with experimental OA induced by surgical destabilization of the meniscus suppressed meniscus and cartilage damage, reducing OA severity. Ad-MKX injection into human OA meniscus tissue explants corrected pathogenic gene expression. These results identify MKX as a previously unidentified key transcription factor that regulates the meniscus cell phenotype. The combination of Ad-MKX with TGF-β3 is effective for differentiation of MSCs to a meniscus cell phenotype and useful for meniscus repair. MKX is a promising therapeutic target for meniscus tissue engineering, repair, and prevention of OA.
Collapse
|
16
|
Patellar resurfacing has minimal impact on in vitro tibiofemoral kinematics during deep knee flexion in total knee arthroplasty. Knee 2021; 30:163-169. [PMID: 33932828 DOI: 10.1016/j.knee.2021.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/22/2021] [Accepted: 04/05/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND While patellar resurfacing can affect patellofemoral kinematics, the effect on tibiofemoral kinematics is unknown. We hypothesized that patellar resurfacing would affect tibiofemoral kinematics during deep knee flexion due to biomechanical alteration of the extensor mechanism. METHODS We performed cruciate-retaining TKA in fresh-frozen human cadaveric knees (N = 5) and recorded fluoroscopic kinematics during deep knee flexion before and after the patellar resurfacing. To simulate deep knee flexion, cadaver knees were tested on a dynamic, quadriceps-driven, closed-kinetic chain simulator based on the Oxford knee rig design under loads equivalent to stair climbing. To measure knee kinematics, a 2-dimensional to 3-dimensional fluoroscopic registration technique was used. Component rotation, varus-valgus angle, and anteroposterior translation of medial and lateral contact points of the femoral component relative to the tibial component were calculated over the range of flexion. RESULTS There were no significant differences in femoral component external rotation (before patellar resurfacing: 6.6 ± 2.3°, after patellar resurfacing: 7.2 ± 1.8°, p = 0.36), and less than 1° difference in femorotibial varus-valgus angle between patellar resurfacing and non-resurfacing (p = 0.01). For both conditions, the medial and lateral femorotibial contact points moved posteriorly from 0° to 30° of flexion, but not beyond 30° of flexion. At 10° of flexion, after patellar resurfacing, the medial contact point was more anteriorly located than before patellar resurfacing. CONCLUSION Despite the potential for alteration of the knee extensor biomechanics, patellar resurfacing had minimal effect on tibiofemoral kinematics. Patellar resurfacing, if performed adequately, is unlikely to affect postoperative knee function.
Collapse
|
17
|
Nanofiber Scaffolds by Electrospinning for Rotator Cuff Tissue Engineering. Chonnam Med J 2021; 57:13-26. [PMID: 33537215 PMCID: PMC7840345 DOI: 10.4068/cmj.2021.57.1.13] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 12/21/2020] [Accepted: 12/22/2020] [Indexed: 12/11/2022] Open
Abstract
Rotator cuff tears continue to be at risk of retear or failure to heal after surgical repair, despite the use of various surgical techniques, which stimulate development of novel scaffolding strategies. They should be able to address the known causes of failure after the conventional rotator cuff repair: (1) failure to reproduce the normal tendon healing process, (2) resultant failure to reproduce four zones of the enthesis, and (3) failure to attain sufficient mechanical strength after repair. Nanofiber scaffolds are suited for this application because they can be engineered to mimic the ultrastructure and properties of the native rotator cuff tendon. Among various methods for tissue-engineered nanofibers, electrospinning has recently been highlighted in the rotator cuff field. Electrospinning can create fibrous and porous structures that resemble natural tendon's extracellular matrix. Other advantages include the ability to create relatively large surface-to-volume ratios, the ability to control fiber size from the micro to the nano scale, and the flexibility of material choices. In this review, we will discuss the anatomical and mechanical features of the rotator cuff tendon, their potential impacts on improper healing after repair, and the current knowledge of the use of electrospinning for rotator cuff tissue engineering.
Collapse
|
18
|
Abstract
The knee menisci are critical to the long-term health of the knee joint. Because of the high incidence of injury and degeneration, replacing damaged or lost meniscal tissue is extremely clinically relevant. The multiscale architecture of the meniscus results in unique biomechanical properties. Nanofibrous scaffolds are extremely attractive to replicate the biochemical composition and ultrastructural features in engineered meniscus tissue. We review recent advances in electrospinning to generate nanofibrous scaffolds and the current state-of-the-art of electrospun materials for meniscal regeneration. We discuss the importance of cellular function for meniscal tissue engineering and the application of cells derived from multiple sources. We compare experimental models necessary for proof of concept and to support translation. Finally, we discuss future directions and potential for technological innovations.
Collapse
|
19
|
Abstract
AIMS The extensive variation in axial rotation of tibial components can lead to coronal plane malalignment. We analyzed the change in coronal alignment induced by tray malrotation. METHODS We constructed a computer model of knee arthroplasty and used a virtual cutting guide to cut the tibia at 90° to the coronal plane. The virtual guide was rotated axially (15° medial to 15° lateral) and with posterior slopes (0° to 7°). To assess the effect of axial malrotation, we measured the coronal plane alignment of a tibial tray that was axially rotated (25° internal to 15° external), as viewed on a standard anteroposterior (AP) radiograph. RESULTS Axial rotation of the cutting guide induced a varus-valgus malalignment up to 1.8° (for 15° of axial rotation combined with 7° of posterior slope). Axial malrotation of tibial tray induced a substantially higher risk of coronal plane malalignment ranging from 1.9° valgus with 15° external rotation, to over 3° varus with 25° of internal rotation. Coronal alignment of the tibial cut changed by 0.07° per degree of axial rotation and 0.22° per degree of posterior slope (linear regression, R2 > 0.99). CONCLUSION While the effect of axial malalignment has been studied, the impact on coronal alignment is not known. Our results indicate that the direction of the cutting guide and malalignment in axial rotation alter coronal plane alignment and can increase the incidence of outliers. Cite this article: Bone Joint J 2020;102-B(6 Supple A):43-48.
Collapse
|
20
|
Huge intrameniscal cyst successfully treated by open debridement and combined arthroscopic and open repair: a case report. BMC Musculoskelet Disord 2020; 21:190. [PMID: 32220248 PMCID: PMC7102424 DOI: 10.1186/s12891-020-03218-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 03/17/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Meniscal cysts are not uncommon in clinical practice, with reported incidence rates varying from 1 to 22%. Most meniscal cysts are parameniscal cysts, which are created by extravasation of synovial fluid through the meniscal tear into the adjacent soft tissue. In contrast, intrameniscal cysts in which the fluid collects in the meniscus are very rare. We encountered a teenager with a huge intrameniscal cyst accompanied by a small vertical meniscal tear in the red-white zone of the upper surface of the medial meniscus. A literature search revealed no information regarding the appropriate treatment methods and results for this type of lesion. CASE PRESENTATION A 14-year-old boy presented to our outpatient clinic because of right knee pain that had been present for the previous 2 months. The patient participated in Hapkido, but had no specific trauma history. Magnetic resonance imaging revealed a huge intrameniscal cyst located in the central parenchyma of the posteromedial corner of the medial meniscus. In addition, one sagittal slice on MRI revealed a vertical tear in the red-white zone of the upper surface of the medial meniscus. The presence of such a tear accompanied by a huge intrameniscal cyst is very unusual. The patient was treated via arthroscopic inside-out meniscal suture repair and open cystic debridement with additional meniscocapsular suturing. During 4 years of magnetic resonance imaging follow-up, the lesion has completely disappeared and the meniscus has successfully recovered its normal form. CONCLUSIONS Our treatment method may be considered as the first choice for young patients who require surgical treatment for large intrameniscal cysts with accompanying small vertical meniscal tears.
Collapse
|
21
|
Minimising tibial fracture after unicompartmental knee replacement: A probabilistic finite element study. Clin Biomech (Bristol, Avon) 2020; 73:46-54. [PMID: 31935599 PMCID: PMC10135372 DOI: 10.1016/j.clinbiomech.2019.12.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 12/11/2019] [Accepted: 12/16/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Periprosthetic tibial fracture after unicompartmental knee replacement is a challenging post-operative complication. Patients have an increased risk of mortality after fracture, the majority undergo further surgery, and the revision operations are less successful. Inappropriate surgical technique increases the risk of fracture, but it is unclear which technical aspects of the surgery are most problematic and no research has been performed on how surgical factors interact. METHODS Firstly, this study quantified the typical variance in surgical cuts made during unicompartmental knee replacement (determined from bones prepared by surgeons during an instructional course). Secondly, these measured distributions were used to create a probabilistic finite element model of the tibia after replacement. A thousand finite element models were created using the Monte Carlo method, representing 1000 virtual operations, and the risk of tibial fracture was assessed. FINDINGS Multivariate linear regression of the results showed that excessive resection depth and making the vertical cut too deep posteriorly increased the risk of fracture. These two parameters also had high variability in the prepared synthetic bones. The regression equation calculated the risk of fracture from three cut parameters (resection depth, vertical and horizonal posterior cuts) and fit the model results with 90% correlation. INTERPRETATION This study introduces for the first time the application of a probabilistic approach to predict the aetiology of fracture after unicompartmental knee replacement, providing unique insight into the relative importance of surgical saw cut variations. Targeted changes to operative technique can now be considered to seek to reduce the risk of periprosthetic fracture.
Collapse
|
22
|
Abstract
Purpose: Scaffold-free cartilage tissue engineering circumvents issues with scaffold seeding, potential toxicity response, and impaired host integration. However, precisely controlling and maintaining a scaffold-free construct shape have been challenging. We explored the feasibility of microneedle arrays to print tissue using cellular microspheroids as building blocks.Materials and Methods: Human embryonic-derived mesenchymal stem cells or infrapatellar fat pad mesenchymal stem cells were used to create microspheroids of 500 µm in diameter, which were assembled on microneedle arrays in a predefined arrangement using a robotic system under computer vision. Microspheroids on microneedles were cultured to permit fusion into a tissue construct. Infrapatellar fat pad mesenchymal stem cell constructs were either implanted into chondral defects created in human osteoarthritic cartilage explants or maintained on the microneedle array for 3 weeks. Embryonic-derived mesenchymal stem cell constructs were designed to be press-fit into 3 mm subchondral defects in New Zealand White rabbits and maintained for up to 8 weeks to assess retention, early tissue repair, and more mature cartilage regeneration.Results: Microspheroids of both cell types fused together in culture to form neotissues of predefined shape and size. Infrapatellar fat pad mesenchymal stem cell neotissues expressed high levels of chondrogenic genes and integrated with the surrounding osteoarthritic host cartilage. Embryonic-derived mesenchymal stem cell constructs generated chondrogenic neotissue in vivo as early as 2 weeks and more mature tissue by 8 weeks with increased glycosaminoglycan deposition.Conclusions: We constructed defined scaffold-free shapes by bioprinting and fusing microspheroids. Proof of concept was shown in the repair of ex vivo osteoarthritic human cartilage and in vivo rabbit osteochondral (OC) defects.
Collapse
|
23
|
FOXO1 and FOXO3 transcription factors have unique functions in meniscus development and homeostasis during aging and osteoarthritis. Proc Natl Acad Sci U S A 2020; 117:3135-3143. [PMID: 31980519 PMCID: PMC7022148 DOI: 10.1073/pnas.1918673117] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
The objective of this study was to examine FoxO expression and FoxO function in meniscus. In menisci from human knee joints with osteoarthritis (OA), FoxO1 and 3 expression were significantly reduced compared with normal menisci from young and old normal donors. The expression of FoxO1 and 3 was also significantly reduced in mouse menisci during aging and OA induced by surgical meniscus destabilization or mechanical overuse. Deletion of FoxO1 and combined FoxO1, 3, and 4 deletions induced abnormal postnatal meniscus development in mice and these mutant mice spontaneously displayed meniscus pathology at 6 mo. Mice with Col2Cre-mediated deletion of FoxO3 or FoxO4 had normal meniscus development but had more severe aging-related damage. In mature AcanCreERT2 mice, the deletion of FoxO1, 3, and 4 aggravated meniscus lesions in all experimental OA models. FoxO deletion suppressed autophagy and antioxidant defense genes and altered several meniscus-specific genes. Expression of these genes was modulated by adenoviral FoxO1 in cultured human meniscus cells. These results suggest that FoxO1 plays a key role in meniscus development and maturation, and both FoxO1 and 3 support homeostasis and protect against meniscus damage in response to mechanical overuse and during aging and OA.
Collapse
|
24
|
Bioactive proteins delivery through core-shell nanofibers for meniscal tissue regeneration. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2019; 23:102090. [PMID: 31493556 DOI: 10.1016/j.nano.2019.102090] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Revised: 08/07/2019] [Accepted: 08/27/2019] [Indexed: 12/29/2022]
Abstract
Mimicking the ultrastructural morphology of the meniscus with nanofiber scaffolds, coupled with controlled growth-factor delivery to the appropriate cells, can help engineer tissue with the potential to grow, mature, and regenerate after in vivo implantation. We electrospun nanofibers encapsulating platelet-derived growth factor (PDGF-BB), which is a potent mitogen and chemoattractant in a core of serum albumin contained within a shell of polylactic acid. We controlled the local PDGF-BB release by adding water-soluble polyethylene glycol to the polylactic acid shell to serve as a porogen. The novel core-shell nanofibers generated 3D scaffolds with an interconnected macroporous structure, with appropriate mechanical properties and with high cell compatibility. Incorporating PDGF-BB increased cell viability, proliferation, and infiltration, and upregulated key genes involved in meniscal extracellular matrix synthesis in human meniscal and synovial cells. Our results support proof of concept that these core-shell nanofibers can create a cell-favorable nanoenvironment and can serve as a system for sustained release of bioactive factors.
Collapse
|
25
|
Abstract
Electrospinning is an attractive method of fabricating nanofibers that replicate the ultrastructure of the human meniscus. However, it is challenging to approximate the mechanical properties of meniscal tissue while maintaining the biocompatibility of collagen fibers. Our objective was to determine if functionalizing polylactic acid (PLA) nanofibers with collagen would enhance their biocompatibility. We therefore used coaxial electrospinning to generate core-shell nanofibers with a core of PLA for mechanical strength and a shell of collagen to enhance cell attachment and matrix synthesis. We characterized the nanostructure of the engineered scaffolds and measured the hydrophilic and mechanical properties. We assessed the performance of human meniscal cells seeded on coaxial electrospun scaffolds to produce meniscal tissue by gene expression and histology. Finally, we investigated whether these cell-seeded scaffolds could repair surgical tears created ex vivo in avascular meniscal explants. Histology, immunohistochemistry, and mechanical testing of ex vivo repair provided evidence of neotissue that was significantly better integrated with the native tissue than with the acellular coaxial electrospun scaffolds. Human meniscal cell-seeded coaxial electrospun scaffolds may have potential in enhancing repair of avascular meniscus tears. Impact Statement The success of any tissue-engineered meniscus graft relies on its ability to mimic native three-dimensional microstructure, support cell growth, produce tissue-specific matrix, and enhance graft integration into the repair site. Polylactic acid scaffolds possess the desired mechanical properties, whereas collagen scaffolds induce better cell attachment and enhanced tissue regeneration. We therefore fabricated nanofibrous scaffolds that combined the properties of two biomaterials. These novel coaxial scaffolds more closely emulated the structure, mechanical properties, and biochemical composition of native meniscal tissue. Our findings of meniscogenic tissue generation and integration in meniscus defects have the potential to be translated to clinical use.
Collapse
|
26
|
Abstract
Hypothesis Musculoskeletal computer models provide valuable insights into shoulder biomechanics. The shoulder is a complex joint composed of glenohumeral, scapulothoracic, acromioclavicular, and sternoclavicular articulations, whose function is largely dependent on the many muscles spanning these joints. However, the range of patient-to-patient variability in shoulder function is largely unknown. We therefore assessed the sensitivity of glenohumeral forces to population-based model input parameters that were likely to influence shoulder function. Methods We constructed musculoskeletal models of the shoulder in the AnyBody Modeling System (AnyBody Technology, Aalborg, Denmark). We used inverse dynamics and static optimization to solve for glenohumeral joint forces during a simulated shoulder elevation. We generated 1000 AnyBody models by uniformly distributing the following input parameters: subject height, scapulohumeral rhythm, humeral head radius, and acromiohumeral interval. Results Increasing body height increased glenohumeral joint forces. Increasing the ratio of scapulothoracic to glenohumeral elevation also increased forces. Increasing humeral head radius and acromiohumeral interval decreased forces. The relative sensitivity of glenohumeral joint forces to input parameters was dependent on the angle of shoulder elevation. We developed an efficient method of generating and simulating musculoskeletal models representing a large population of shoulder arthroplasty patients. We found that scapulohumeral rhythm had a significant influence on glenohumeral joint force. Conclusions This finding underscores the importance of more accurately measuring and simulating scapulothoracic motion rather than using fixed ratios or average scapulothoracic motion. This modeling approach can be used to generate virtual populations for conducting efficient simulations and generating statistical conclusions.
Collapse
|
27
|
Clinical and radiographic results of partial versus total meniscectomy in patients with symptomatic discoid lateral meniscus: A systematic review and meta-analysis. Orthop Traumatol Surg Res 2019; 105:669-675. [PMID: 31027980 DOI: 10.1016/j.otsr.2019.02.023] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 01/24/2019] [Accepted: 02/14/2019] [Indexed: 02/02/2023]
Abstract
PURPOSE Some reports have noted favorable long-term clinical results with milder postoperative arthritic changes after total meniscectomy in symptomatic patients with torn discoid lateral meniscus (DLM). This meta-analysis was conducted to compare the clinical and radiographic results between partial and total meniscectomy in patients with symptomatic DLM. METHODS Studies were included in the meta-analysis if (1) they analysed patients who underwent arthroscopic surgeries for DLMs, (2) they directly compared clinical outcomes in patients treated with partial and total meniscectomies, (3) they analysed at least one parameter related to postoperative outcomes, including the Ikeuchi scale, and/or radiographic results including the Tapper and Hoover classification. RESULTS Eight studies were finally included. The proportion of the knees with excellent or good grade appeared to be higher in partial than in total meniscectomy group, but this difference did not reach statistical significance [128/158 (81.0%) vs. 87/131 (66.4%); OR 1.62; p=0.10; I2=0%]. The pooled results of the proportion of normal cartilage status or mild chondral wear (grade 0 or 1 of the Tapper and Hoover classification) were significantly much higher with partial than with total meniscectomy [228/261 (87.4%) vs. 94/169 (55.6%); OR 9.08; p<0.001; I2=57%]. CONCLUSION This meta-analysis showed that the radiographic outcomes of DLM were better with partial meniscectomy with or without repair than with total meniscectomy, but their clinical outcomes were similar. The findings thus suggest that meniscal preservation would be a better option than total meniscectomy for symptomatic DLM. LEVEL OF EVIDENCE II, Systematic review and Meta-analysis.
Collapse
|
28
|
In Vitro and In Vivo Performance of Tissue-Engineered Tendons for Anterior Cruciate Ligament Reconstruction: Response. Am J Sports Med 2018; 46:NP61-NP63. [PMID: 30280931 DOI: 10.1177/0363546518800696] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
29
|
Platelet-derived growth factor-coated decellularized meniscus scaffold for integrative healing of meniscus tears. Acta Biomater 2018; 76:126-134. [PMID: 29908335 DOI: 10.1016/j.actbio.2018.06.021] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 06/11/2018] [Accepted: 06/12/2018] [Indexed: 11/30/2022]
Abstract
The aim of this study was to examine the potential of platelet-derived growth factor (PDGF)-coated decellularized meniscus scaffold in mediating integrative healing of meniscus tears by inducing endogenous cell migration. Fresh bovine meniscus was chemically decellularized and covalently conjugated with heparin and PDGF-BB. In vitro PDGF release kinetics was measured. The scaffold was transplanted into experimental tears in avascular bovine meniscus explants and cultured for 2 and 4 weeks. The number migrating and proliferating cells at the borderline between the scaffold and injured explant and PDGF receptor-β (PDGFRβ) expressing cells were counted. The alignment of the newly produced ECM and collagen was analyzed by Safranin-O, picrosirius red staining, and differential interference contrast (DIC). Tensile testing of the explants was performed after culture for 2 and 4 weeks. Heparin conjugated scaffold showed immobilization of high levels of PDGF-BB, with sustained release over 2 weeks. Insertion of the PDGF-BB treated scaffold in defects in avascular meniscus led to increased PDGFRβ expression, cell migration and proliferation into the defect zone. Safranin-O, picrosirius red staining and DIC showed tissue integration between the scaffold and injured explants. Tensile properties of injured explants treated with PDGF-BB coated scaffold were significantly higher than in the scaffold without PDGF. In conclusion, PDGF-BB-coated scaffold increased PDGFRβ expression and promoted migration of endogenous meniscus cells to the defect area. New matrix was formed that bridged the space between the native meniscus and the scaffold and this was associated with improved biomechanical properties. The PDGF-BB-coated scaffold will be promising for clinical translation to healing of meniscus tears. STATEMENT OF SIGNIFICANCE Meniscus tears are the most common injury of the knee joint. The most prevalent forms that occur in the inner third typically do not spontaneously heal and represent a major risk factor for the development of knee osteoarthritis. The goal of this project was to develop an approach that is readily applicable for clinical use. We selected a natural and readily available decellularized meniscus scaffold and conjugated it with PDGF, which we had previously found to have strong chemotactic activity for chondrocytes and progenitor cells. The present results show that insertion of the PDGF-conjugated scaffold in defects in avascular meniscus led to endogenous cell migration and proliferation into the defect zone with tissue integration between the scaffold and injured explants and improved tensile properties. This PDGF-conjugated scaffold will be promising for a translational approach to healing of meniscus tears.
Collapse
|
30
|
Second-Generation Electronic Ligament Balancing for Knee Arthroplasty: A Cadaver Study. J Arthroplasty 2018; 33:2293-2300. [PMID: 29555494 DOI: 10.1016/j.arth.2018.02.057] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 02/12/2018] [Accepted: 02/13/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Knee instability is emerging as a major complication after total knee arthroplasty (TKA), with ligament laxity and component alignment listed as important contributory factors. Knee balancing remains an art and is largely dependent on the surgeon's subjective "feel." The objectives were to measure the accuracy of an electronic balancing device to document the magnitude of correction in knee balance after soft-tissue releases and measure change in knee laxity after medial release. METHODS The accuracy of a second-generation electronic ligament-balancing device was compared with that of 2 mechanical balancing instruments. TKA was performed in 12 cadaver knees. Soft-tissue balance was measured sequentially before TKA, after mounting a trial femoral component, after medial release, and after resecting the posterior cruciate ligament. Coronal laxity of the knee under a 10 Nm valgus moment was measured before and after medial release. RESULTS The electronic balancing instrument was more accurate than mechanical instruments in measuring distracted gap and distraction force. On average, before TKA, the flexion gap was wider than the extension gap, and the medial gap was tighter than the lateral gap. Medial release increased the medial gap in flexion and increased passive knee valgus laxity. Posterior cruciate ligament release increased the tibiofemoral gap in both flexion and extension with a greater increase in the lateral gap. CONCLUSION The second-generation electronic balancing device was significantly more accurate than mechanical instruments and could record knee balance over the entire range of flexion. More accurate soft-tissue balance may enhance outcomes after TKA.
Collapse
|
31
|
In Vitro and In Vivo Performance of Tissue-Engineered Tendons for Anterior Cruciate Ligament Reconstruction. Am J Sports Med 2018; 46:1641-1649. [PMID: 29578751 DOI: 10.1177/0363546518759729] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Anterior cruciate ligament (ACL) reconstruction is the current standard of care for ACL tears. However, the results are not consistently successful; autografts or allografts have certain disadvantages; and synthetic grafts have had poor clinical results. PURPOSE To determine if recellularization of decellularized tendons combined with mechanical stimulation in a bioreactor could replicate the mechanical properties of the native ACL and be successfully used for ACL reconstruction in vivo. STUDY DESIGN Controlled laboratory study. METHODS Porcine tibialis tendons were decellularized and then recellularized with human adult bone marrow-derived stem cells. Tendons were cultured in a tissue bioreactor that provided biaxial cyclic loading for up to 7 days. To reproduce mechanical stresses similar to those experienced by the ACL within the knee joint, the tendons were subjected to simultaneous tension and torsion in the bioreactor. Expression of tendon-specific genes and newly synthesized collagen and glycosaminoglycan were used to quantify the efficacy of recellularization and dynamic bioreactor culture. The ultimate tensile load to failure and stiffness of recellularized constructs were measured after dynamic stimulation. Finally, the tissue-engineered tendons were used to reconstruct the ACL in 24 pigs, and ultimate tensile load to failure and stiffness were assessed after 3 months. RESULTS Dynamic bioreactor culture significantly increased the expression of tendon-specific genes, the quantity of newly synthesized collagen and glycosaminoglycan, and the ultimate tensile load and stiffness of recellularized tendons. After in vivo reconstruction, the ultimate tensile load and stiffness of the tissue-engineered tendons increased significantly up to 3 months after surgery and were within 80% of the ultimate tensile load of the natural ACL. CONCLUSION This translational study indicates that recellularization and dynamic mechanical stimuli can significantly enhance matrix synthesis and ultimate tensile load of decellularized porcine tibialis tendons. This approach to tissue engineering can be very useful for ACL reconstruction and may overcome some of the disadvantages of autografts and allografts. CLINICAL RELEVANCE Dynamic bioreactor cultivation of tissue-engineered tendons may overcome the limitations of autografts and allografts.
Collapse
|
32
|
Translation of the humeral head scale is associated with success of rotator cuff repair for large-massive tears. BMC Musculoskelet Disord 2017; 18:511. [PMID: 29202746 PMCID: PMC5715556 DOI: 10.1186/s12891-017-1874-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Accepted: 11/24/2017] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Although a loss of rotator cuff integrity leads to the superior migration of the humeral head, the parameters that characterize the anterolateral migration of the humeral head have not been established. The purpose of this study was to investigate the correlation between the translation of the humeral head scale (T-scale) and clinical outcomes of rotator cuff repair, as well as the correlation between the T-scale and radiologic parameters. METHODS One hundred thirty-five consecutive patients with full-thickness rotator cuff tears underwent primary rotator cuff repair. The T-scale, which indicates the distance from the center of the humeral head to the lateral coracoacromial arch, was measured on axial computed tomography scans, and the acromiohumeral interval (AHI) was measured radiographically. The correlation of the two parameters with the clinical scores of the Japanese Orthopaedic Association and University of California-Los Angeles scores and active forward elevation (FE) were evaluated at the preoperative and postoperative stages, respectively. RESULTS The postoperative T-scale and AHI correlated well with the postoperative FE and clinical scores in the patients with large-massive tears but not in those patients with small-medium tears and preoperative large-massive tears. A significant correlation was observed between the postoperative T-scale and AHI. The T-scale was subject to cuff repair integrity. CONCLUSIONS We demonstrated that the postoperative T-scale was well correlated with the clinical results and postoperative AHI after rotator cuff repair for large-massive tears, indicating that poor outcomes are associated with combined superior and anterolateral migration of the humeral head following retears.
Collapse
|
33
|
Compromised autophagy precedes meniscus degeneration and cartilage damage in mice. Osteoarthritis Cartilage 2017; 25:1880-1889. [PMID: 28801209 PMCID: PMC5650923 DOI: 10.1016/j.joca.2017.07.023] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 07/18/2017] [Accepted: 07/31/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Autophagy is a cellular homeostasis mechanism that facilitates normal cell function and survival. Objectives of this study were to determine associations between autophagic responses with meniscus injury, joint aging, and osteoarthritis (OA), and to establish the temporal relationship with structural changes in menisci and cartilage. METHODS Constitutive activation of autophagy during aging was measured in GFP-LC3 transgenic reporter mice between 6 and 30 months. Meniscus injury was created by surgically destabilizing the medial meniscus (DMM) to induce posttraumatic OA in C57BL/6J mice. Levels of autophagy proteins and activation were analyzed by confocal microscopy and immunohistochemistry. Associated histopathological changes, such as cellularity, matrix staining, and structural damage, were graded in the meniscus and compared to changes in articular cartilage. RESULTS In C57BL/6J mice, basal autophagy was lower in the meniscus than in articular cartilage. With increasing age, expression of the autophagy proteins ATG5 and LC3 was significantly reduced by 24 months. Age-related changes included abnormal Safranin-O staining and reduced cellularity, which preceded structural damage in the meniscus and articular cartilage. In mice with DMM, autophagy was induced in the meniscus while it was suppressed in cartilage. Articular cartilage exhibited the most profound changes in autophagy and structure that preceded meniscus degeneration. Systemic administration of rapamycin to mice with DMM induced autophagy activation in cartilage and reduced degenerative changes in both meniscus and cartilage. CONCLUSION Autophagy is significantly affected in the meniscus during aging and injury and precedes structural damage. Maintenance of autophagic activity appears critical for meniscus and cartilage integrity.
Collapse
MESH Headings
- Aging/metabolism
- Animals
- Autophagy/drug effects
- Autophagy/physiology
- Autophagy-Related Protein 5/metabolism
- Cartilage, Articular/drug effects
- Cartilage, Articular/pathology
- Green Fluorescent Proteins/genetics
- Immunosuppressive Agents/pharmacology
- Menisci, Tibial/pathology
- Menisci, Tibial/surgery
- Mice
- Mice, Inbred C57BL
- Mice, Transgenic
- Microscopy, Confocal
- Microtubule-Associated Proteins/metabolism
- Osteoarthritis, Knee/etiology
- Osteoarthritis, Knee/pathology
- Osteoarthritis, Knee/physiopathology
- Sirolimus/pharmacology
- Tibial Meniscus Injuries/complications
Collapse
|
34
|
Meniscal Tissue Engineering Using Aligned Collagen Fibrous Scaffolds: Comparison of Different Human Cell Sources. Tissue Eng Part A 2017; 24:81-93. [PMID: 28463545 DOI: 10.1089/ten.tea.2016.0205] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Hydrogel and electrospun scaffold materials support cell attachment and neotissue development and can be tuned to structurally and mechanically resemble native extracellular matrix by altering either electrospun fiber or hydrogel properties. In this study, we examined meniscus tissue generation from different human cell sources including meniscus cells derived from vascular and avascular regions, human bone marrow-derived mesenchymal stem cells, synovial cells, and cells from the infrapatellar fat pad (IPFP). All cells were seeded onto aligned electrospun collagen type I scaffolds and were optionally encapsulated in a tricomponent hydrogel. Single or multilayered constructs were generated and cultivated in defined medium with selected growth factors for 2 weeks. Cell viability, cell morphology, and gene-expression profiles were monitored using confocal microscopy, scanning electron microscopy, and quantitative polymerase chain reaction (qPCR), respectively. Multilayered constructs were examined with histology, immunohistochemistry, qPCR, and for tensile mechanical properties. For all cell types, TGFβ1 and TGFβ3 treatment increased COL1A1, COMP, Tenascin C (TNC), and Scleraxis (SCX) gene expression and deposition of collagen type I protein. IPFP cells generated meniscus-like tissues with higher meniscogenic gene expression, mechanical properties, and better cell distribution compared to other cell types studied. We show proof of concept that electrospun collagen scaffolds support neotissue formation and IPFP cells have potential for use in cell-based meniscus regeneration strategies.
Collapse
|
35
|
Use of an Anti-Gravity Treadmill for Early Postoperative Rehabilitation After Total Knee Replacement: A Pilot Study to Determine Safety and Feasibility. AMERICAN JOURNAL OF ORTHOPEDICS (BELLE MEAD, N.J.) 2016; 45:E167-E173. [PMID: 27327921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The objective was to determine the safety, feasibility, and effects of anti-gravity gait training on functional outcomes (Knee Injury and Osteoarthritis Outcome Score [KOOS], the Timed Up and Go test [TUG], Numerical Rating Scale [NRS] for pain) with the AlterG® Anti-Gravity Treadmill® device for total knee arthroplasty (TKA) rehabilitation. Subjects (N = 30) were randomized to land-based vs anti-gravity gait training over 4 weeks of physical therapy after TKA. Adverse events, complications, and therapist satisfaction were recorded. All patients completed rehabilitation protocols without adverse events. KOOS, TUG, and NRS scores improved in both groups with no significant differences between groups. For the AlterG group, Sports/Recreation and Quality of Life subscales of the KOOS had the most improvement. At the end of physical therapy, TUG and NRS pain scores improved from 14 seconds to 8 seconds and from 2.8 to 1.1, respectively. Subjectively, therapists reported 100% satisfaction with the AlterG. This initial pilot study demonstrated that the AlterG Anti-Gravity Treadmill device was safe and feasible. While functional outcomes improved over time with use of the anti-gravity gait training, further studies are needed to define the role of this device as an alternative or adjunct to established rehabilitation protocols.
Collapse
|
36
|
Posterior augmented glenoid implants require less bone removal and generate lower stresses: a finite element analysis. J Shoulder Elbow Surg 2016; 25:823-30. [PMID: 26775743 DOI: 10.1016/j.jse.2015.10.003] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Revised: 10/09/2015] [Accepted: 10/18/2015] [Indexed: 02/01/2023]
Abstract
HYPOTHESIS Glenoid retroversion can be corrected with standard glenoid implants after anterior-side asymmetric reaming or by using posterior augmented glenoid implants with built-in corrections. The purpose of this study was to compare 2 augmented glenoid designs with a standard glenoid design, measure the amount of bone removed, and compute the stresses generated in the cement and bone. METHODS Finite element models of 3 arthritic scapulae with varying severities of posterior glenoid wear were each implanted with 4 different implant configurations: standard glenoid implant in neutral alignment with asymmetric reaming, standard glenoid implant in retroversion, glenoid implant augmented with a posterior wedge in neutral alignment, and glenoid implant augmented with a posterior step in neutral alignment. The volume of cortical and cancellous bone removed and the percentage of implant back surface supported by cortical bone were measured. Stresses and strains in the implant, cement, and glenoid bone were computed. RESULTS Asymmetric reaming for the standard implant in neutral version required the most bone removal, resulted in the lowest percentage of back surface supported by cortical bone, and generated strain levels that risked damage to the most bone volume. The wedged implant removed less bone, had a significantly greater percentage of the back surface supported by cortical bone, and generated strain levels that risked damage to significantly less bone volume. CONCLUSIONS The wedged glenoid implants appear to have various advantages over the standard implant for the correction of retroversion. LEVEL OF EVIDENCE Basic Science Study; Computer Modeling.
Collapse
|
37
|
Repair of Avascular Meniscus Tears with Electrospun Collagen Scaffolds Seeded with Human Cells. Tissue Eng Part A 2016; 22:436-48. [PMID: 26842062 PMCID: PMC4800276 DOI: 10.1089/ten.tea.2015.0284] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The self-healing capacity of an injured meniscus is limited to the vascularized regions and is especially challenging in the inner avascular regions. As such, we investigated the use of human meniscus cell-seeded electrospun (ES) collagen type I scaffolds to produce meniscal tissue and explored whether these cell-seeded scaffolds can be implanted to repair defects created in meniscal avascular tissue explants. Human meniscal cells (derived from vascular and avascular meniscal tissue) were seeded on ES scaffolds and cultured. Constructs were evaluated for cell viability, gene expression, and mechanical properties. To determine potential for repair of meniscal defects, human meniscus avascular cells were seeded and cultured on aligned ES collagen scaffolds for 4 weeks before implantation. Surgical defects resembling "longitudinal tears" were created in the avascular zone of bovine meniscus and implanted with cell-seeded collagen scaffolds and cultured for 3 weeks. Tissue regeneration and integration were evaluated by histology, immunohistochemistry, mechanical testing, and magentic resonance imaging. Ex vivo implantation with cell-seeded collagen scaffolds resulted in neotissue that was significantly better integrated with the native tissue than acellular collagen scaffolds or untreated defects. Human meniscal cell-seeded ES collagen scaffolds may therefore be useful in facilitating meniscal repair of avascular meniscus tears.
Collapse
|
38
|
Hyaluronan concentration and size distribution in human knee synovial fluid: variations with age and cartilage degeneration. Arthritis Res Ther 2016; 18:18. [PMID: 26792492 PMCID: PMC4721052 DOI: 10.1186/s13075-016-0922-4] [Citation(s) in RCA: 71] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 01/05/2016] [Indexed: 12/04/2022] Open
Abstract
Background One potential mechanism for early superficial cartilage wear in normal joints is alteration of the lubricant content and quality of synovial fluid. The purpose of this study was to determine if the concentration and quality of the lubricant, hyaluronan, in synovial fluid: (1) was similar in left and right knees; (2) exhibited similar age-associated trends, whether collected postmortem or antemortem; and (3) varied with age and grade of joint degeneration. Methods Human synovial fluid of donors (23–91 years) without osteoarthritis was analyzed for the concentrations of protein, hyaluronan, and hyaluronan in the molecular weight ranges of 2.5–7 MDa, 1–2.5 MDa, 0.5–1 MDa, and 0.03–0.5 MDa. Similarity of data between left and right knees was assessed by reduced major axis regression, paired t-test, and Bland-Altman analysis. The effect of antemortem versus postmortem collection on biochemical properties was assessed for age-matched samples by unpaired t-test. The relationships between age, joint grade, and each biochemical component were assessed by regression analysis. Results Joint grade and the concentrations of protein, hyaluronan, and hyaluronan in the molecular weight ranges of 2.5–7 MDa, 1–2.5 MDa, and 0.5–1 MDa in human synovial fluid showed good agreement between left and right knees and were similar between age-matched patient and cadaver knee joints. There was an age-associated decrease in overall joint grade (–15 %/decade) and concentrations of hyaluronan (–10.5 %/decade), and hyaluronan in the molecular weight ranges of 2.5–7 MDa (–9.4 %/decade), 1–2.5 MDa (–11.3 %/decade), 0.5–1 MDa (–12.5 %/decade), and 0.03–0.5 MDa (–13.0 %/decade). Hyaluronan concentration and quality was more strongly associated with age than with joint grade. Conclusions The age-related increase in cartilage wear in non-osteoarthritic joints may be related to the altered hyaluronan content and quality of synovial fluid.
Collapse
|
39
|
Patient-specific implants with custom cutting blocks better approximate natural knee kinematics than standard TKA without custom cutting blocks. Knee 2015; 22:624-9. [PMID: 27092379 DOI: 10.1016/j.knee.2015.08.002] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND Nearly 14% to 39% TKA patients report dissatisfaction causing incomplete return of function. We proposed that the kinematics of knees implanted with patient-specific prostheses using patient-specific cutting guides would be closer to normal. METHODS Eighteen matched cadaver lower limbs were randomly assigned to two groups: group A was implanted with patient-specific implants using patient-specific cutting guides; group B, the contralateral knee, was implanted with a standard design using intramedullary alignment cutting guides. Knee kinematics were measured on a dynamic closed-kinetic-chain Oxford knee rig, simulating a deep knee bend and in a passive rig testing varus-valgus laxity. RESULTS The difference from normal kinematics was lower for group A compared to group B for active femoral rollback, active tibiofemoral adduction, and for passive varus-valgus laxity. CONCLUSIONS Our results support the hypothesis that knees with patient-specific implants generate kinematics more closely resembling normal knee kinematics than standard knee designs. CLINICAL RELEVANCE Restoring normal kinematics may improve function and patient satisfaction after total knee arthroplasty.
Collapse
|
40
|
Muscle synergies may improve optimization prediction of knee contact forces during walking. J Biomech Eng 2014; 136:021031. [PMID: 24402438 DOI: 10.1115/1.4026428] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Accepted: 01/07/2014] [Indexed: 11/08/2022]
Abstract
The ability to predict patient-specific joint contact and muscle forces accurately could improve the treatment of walking-related disorders. Muscle synergy analysis, which decomposes a large number of muscle electromyographic (EMG) signals into a small number of synergy control signals, could reduce the dimensionality and thus redundancy of the muscle and contact force prediction process. This study investigated whether use of subject-specific synergy controls can improve optimization prediction of knee contact forces during walking. To generate the predictions, we performed mixed dynamic muscle force optimizations (i.e., inverse skeletal dynamics with forward muscle activation and contraction dynamics) using data collected from a subject implanted with a force-measuring knee replacement. Twelve optimization problems (three cases with four subcases each) that minimized the sum of squares of muscle excitations were formulated to investigate how synergy controls affect knee contact force predictions. The three cases were: (1) Calibrate+Match where muscle model parameter values were calibrated and experimental knee contact forces were simultaneously matched, (2) Precalibrate+Predict where experimental knee contact forces were predicted using precalibrated muscle model parameters values from the first case, and (3) Calibrate+Predict where muscle model parameter values were calibrated and experimental knee contact forces were simultaneously predicted, all while matching inverse dynamic loads at the hip, knee, and ankle. The four subcases used either 44 independent controls or five synergy controls with and without EMG shape tracking. For the Calibrate+Match case, all four subcases closely reproduced the measured medial and lateral knee contact forces (R2 ≥ 0.94, root-mean-square (RMS) error < 66 N), indicating sufficient model fidelity for contact force prediction. For the Precalibrate+Predict and Calibrate+Predict cases, synergy controls yielded better contact force predictions (0.61 < R2 < 0.90, 83 N < RMS error < 161 N) than did independent controls (-0.15 < R2 < 0.79, 124 N < RMS error < 343 N) for corresponding subcases. For independent controls, contact force predictions improved when precalibrated model parameter values or EMG shape tracking was used. For synergy controls, contact force predictions were relatively insensitive to how model parameter values were calibrated, while EMG shape tracking made lateral (but not medial) contact force predictions worse. For the subject and optimization cost function analyzed in this study, use of subject-specific synergy controls improved the accuracy of knee contact force predictions, especially for lateral contact force when EMG shape tracking was omitted, and reduced prediction sensitivity to uncertainties in muscle model parameter values.
Collapse
|
41
|
Abstract
Background: Injuries to the glenoid labrum frequently require repair with anchors. Placing anchor devices arthroscopically can be challenging, and anchor malpositioning can complicate surgical outcomes. Purpose: To determine the safe insertion range and optimal insertion angle of glenoid labral anchors at various positions on the glenoid rim and to establish surgical guidelines that minimize risk of anchor perforation. Study Design: Descriptive laboratory study. Methods: Three-dimensional computed tomography scans of 30 normal cadaveric specimens were obtained. A virtual model of a generic labral anchor was inserted into the rim of the glenoid at the clockface positions represented by 12:00, 1:30, 3:00, 4:30, 6:00, 7:30, 9:00, and 10:30. At each position, the safe insertion range was the maximal range measured, and the optimal insertion angle was identified as the angle between the bisector of the safe insertion range and the glenoid face. Results: Progressing in the clockwise direction, beginning at the 12:00 position, the safe insertion ranges (mean ± SD ) were 55.9° ± 10.6°, 63.6° ± 17.6°, 47.7° ± 9.1°, 46.1° ± 8°, 73.9° ± 9.7°, 40.9° ± 6.5°, 40.4° ± 7.4°, and 39.9° ± 7.1°, respectively. The optimal insertion angles were 47.9° ± 7.6°, 53.1° ± 10.9°, 35.0° ± 4.4°, 42.4° ± 4.9°, 60.9° ± 8.4°, 36.6° ± 5.9°, 31.2° ± 4.9°, 34.8° ± 4.6°, respectively. Conclusion: Optimal insertion angles and safe insertion ranges varied significantly with respect to the position on the glenoid face. The safe insertion range and optimal insertion angle were found to be wider at the anterior glenoid as compared with the posterior glenoid. A posterolateral insertion angle was safer than an anterior insertion angle at the 10:30 position. Clinical Relevance: Proper arthroscopic technique resulting in anchor insertion at the correct angle, depth, and location will prevent anchor-related glenohumeral complications such as glenoid perforation, cartilage damage, persistent pain, decreased range of motion, and failure of the reconstruction.
Collapse
|
42
|
Effect of head diameter on passive and active dynamic hip dislocation. J Orthop Res 2014; 32:1525-31. [PMID: 24961686 DOI: 10.1002/jor.22659] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Accepted: 05/13/2014] [Indexed: 02/04/2023]
Abstract
Hip dislocation is a major short-term complication after total hip arthroplasty (THA). One factor thought to reduce the risk for dislocation is head size. We constructed subject-specific computer models to study the effect of head size on risk for postoperative dislocation. Femoral and acetabular geometry was constructed after segmenting CT scans of nine hips. CAD models of THA components with four head diameters (28, 32, 36, and 44 mm) were virtually implanted. Hip capsular ligaments were simulated using rigid-body ellipsoids connected by non-linear springs. Posterior dislocation was simulated during a rise from a low chair; anterior dislocation was simulated during a pivot activity. Intraoperative stability tests were simulated for anterior or posterior dislocation. While rising from a low chair (posterior dislocation) and during the pivot activity (anterior dislocation), increasing head size significantly increased hip flexion angle at dislocation and generated higher dislocation moments. Larger heads reduced the risk for dislocation. Intraoperative stability tests detected the relative increased resistance to dislocation despite differences in the absolute magnitude of moments. This model can be useful preclinical tool for assessing design changes, the effect of component placement, and the activity-based risk for dislocation.
Collapse
|
43
|
Effect of microseparation and third-body particles on dual-mobility crosslinked hip liner wear. J Arthroplasty 2014; 29:1849-53. [PMID: 24891003 DOI: 10.1016/j.arth.2014.04.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 03/25/2014] [Accepted: 04/08/2014] [Indexed: 02/01/2023] Open
Abstract
Large heads have been recommended to reduce the risk of dislocation after total hip arthroplasty. One of the issues with larger heads is the risk of increased wear and damage in thin polyethylene liners. Dual-mobility liners have been proposed as an alternative to large heads. We tested the wear performance of highly crosslinked dual-mobility liners under adverse conditions simulating microseparation and third-body wear. No measurable increase in polyethylene wear rate was found in the presence of third-body particles. Microseparation induced a small increase in wear rate (2.9mm(3)/million cycles). A finite element model simulating microseparation in dual-mobility liners was validated using these experimental results. The results of our study indicate that highly crosslinked dual-mobility liners have high tolerance for third-body particles and microseparation.
Collapse
|
44
|
Magnetic resonance imaging assessed cortical porosity is highly correlated with μCT porosity. Bone 2014; 66:56-61. [PMID: 24928498 PMCID: PMC4125420 DOI: 10.1016/j.bone.2014.06.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2013] [Revised: 05/29/2014] [Accepted: 06/02/2014] [Indexed: 12/29/2022]
Abstract
Cortical bone is typically regarded as "MR invisible" with conventional clinical magnetic resonance imaging (MRI) pulse sequences. However, recent studies have demonstrated that free water in the microscopic pores of cortical bone has a short T2* but a relatively long T2, and may be detectable with conventional clinical spin echo (SE) or fast spin echo (FSE) sequences. In this study we describe the use of a conventional two-dimensional (2D) FSE sequence to assess cortical bone microstructure and measure cortical porosity using a clinical 3T scanner. Twelve cadaveric human cortical bone samples were studied with MRI and microcomputed tomography (μCT) (downsampled to the same spatial resolution). Preliminary results show that FSE-determined porosity is highly correlated (R(2)=0.83; P<0.0001) with μCT porosity. Bland-Altman analysis suggested a good agreement between FSE and μCT with tight limit of agreement at around 3%. There is also a small bias of -2% for the FSE data, which suggested that the FSE approach slightly underestimated μCT porosity. The results demonstrate that cortical porosity can be directly assessed using conventional clinical FSE sequences. The clinical feasibility of this approach was also demonstrated on six healthy volunteers using 2D FSE sequences as well as 2D ultrashort echo time (UTE) sequences with a minimal echo time (TE) of 8μs, which provide high contrast imaging of cortical bone in vivo.
Collapse
|
45
|
Reverse total shoulder arthroplasty component center of rotation affects muscle function. J Shoulder Elbow Surg 2014; 23:1128-35. [PMID: 24613182 DOI: 10.1016/j.jse.2013.11.025] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2013] [Revised: 11/18/2013] [Accepted: 11/22/2013] [Indexed: 02/01/2023]
Abstract
BACKGROUND Medialization of the glenohumeral center of rotation alters the moment arm of the deltoid, can affect muscle function, and increases the risk for scapular notching due to impingement. The objective of this study was to determine the effect of position of the glenosphere on deltoid efficiency and the range of glenohumeral adduction. METHODS Scapulohumeral bone models were reconstructed from computed tomography scans and virtually implanted with primary or reverse total shoulder arthroplasty implants. The placement of the glenosphere was varied to simulate differing degrees of "medialization" and inferior placement relative to the glenoid. Muscle and joint forces were computed during shoulder abduction in OpenSim musculoskeletal modeling software. RESULTS The average glenohumeral joint reaction forces for the primary total shoulder arthroplasty were within 5% of those previously reported in vivo. Superior placement or full lateralization of the glenosphere increased glenohumeral joint reaction forces by 10% and 18%, respectively, relative to the recommended reverse total shoulder arthroplasty position. The moment arm of the deltoid muscle was the highest at the recommended baseline surgical position. The baseline glenosphere position resulted in a glenohumeral adduction deficit averaging more than 10° that increased to more than 25° when the glenosphere was placed superiorly. Only with full lateralization was glenohumeral adduction unaffected by superoinferior placement. DISCUSSION/CONCLUSION Selecting optimum placement of the glenosphere involves tradeoffs in bending moment at the implant-bone interface, risk for impingement, and deltoid efficiency. A viable option is partially medializing the glenosphere, which retains most of the benefits of deltoid efficiency and reduces the risk for scapular notching.
Collapse
|
46
|
Augmented wedge-shaped glenoid component for the correction of glenoid retroversion: a finite element analysis. J Shoulder Elbow Surg 2014; 23:347-54. [PMID: 24007648 DOI: 10.1016/j.jse.2013.06.008] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Revised: 05/29/2013] [Accepted: 06/01/2013] [Indexed: 02/01/2023]
Abstract
BACKGROUND This study undertook a computational analysis of a wedged glenoid component for correction of retroverted glenoid arthritic deformity to determine whether a wedge-shaped glenoid component design with a built-in correction for version reduces excessive stresses in the implant, cement, and glenoid bone. Recommendations for correcting retroversion deformity are asymmetric reaming of the anterior glenoid, bone grafting of the posterior glenoid, or a glenoid component with posterior augmentation. Eccentric reaming has the disadvantages of removing normal bone, reducing structural support for the glenoid component, and increasing the risk of bone perforation by the fixation pegs. Bone grafting to correct retroverted deformity does not consistently generate successful results. METHODS Finite element models of 2 scapulae models representing a normal and an arthritic retroverted glenoid were implanted with a standard glenoid component (in retroversion or neutral alignment) or a wedged component. Glenohumeral forces representing in vivo loading were applied and stresses and strains computed in the bone, cement, and glenoid component. RESULTS The retroverted glenoid components generated the highest compressive stresses and decreased cyclic fatigue life predictions for trabecular bone. Correction of retroversion by the wedged glenoid component significantly decreased stresses and predicted greater bone fatigue life. The cement volume estimated to survive 10 million cycles was the lowest for the retroverted components and the highest for neutrally implanted glenoid components and for wedged components. CONCLUSION A wedged glenoid implant is a viable option to correct severe arthritic retroversion, reducing the need for eccentric reaming and the risk for implant failure.
Collapse
|
47
|
Comparative biomechanical analysis of human and caprine knee articular cartilage. Knee 2014; 21:119-25. [PMID: 23583005 DOI: 10.1016/j.knee.2013.03.009] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2012] [Revised: 10/19/2012] [Accepted: 03/14/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND The goat is one of the most commonly used preclinical models for focal defect repair and regeneration. While the biomechanics of the human knee has been studied extensively, less is known about the biomechanics of the caprine knee. Differences between human and caprine knees have not been quantified and their significance is largely unknown. METHODS We conducted a biomechanical analysis of the differences in goat and human knees to assess the validity of these preclinical in vivo models. RESULTS CT and MRI scans revealed several differences in articular geometry: the caprine tibial plateaux were more convex and the menisci were significantly thicker and covered a larger proportion of the tibial articular surface. Caprine cartilage thickness was consistently thinner, while elastic modulus on indentation testing was consistently stiffer than human cartilage measured at eight different articular locations. Contact area and pressure were measured with electronic pressure sensors under loads normalized by multiples of body weight and at knee flexion angles reported for walking. The highest peaks in contact pressure were measured in the patellofemoral joint in goat and human knees. Peak contact pressure measured at 2 times body weight at the goat tibiofemoral joint at 70° flexion was significantly higher than for any other condition at the human tibiofemoral joint. CONCLUSION These differences in contact conditions might explain the lower quality of local repair reported for caprine femoral condylar defects relative to trochlear defects. Further comparative analysis, including biologic response, is necessary to determine the extent to which the goat knee reproduces clinical conditions.
Collapse
|
48
|
Repair of cartilage defects in arthritic tissue with differentiated human embryonic stem cells. Tissue Eng Part A 2013; 20:683-92. [PMID: 24028447 DOI: 10.1089/ten.tea.2012.0751] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Chondrocytes have been generated in vitro from a range of progenitor cell types and by a number of strategies. However, achieving reconstitution of actual physiologically relevant, appropriately-laminated cartilage in situ that would be applicable to conditions, such as arthritis and cartilage degeneration remains elusive. This lack of success is multifactorial and includes limited cell source, decreased proliferation rate of mature chondrocytes, lack of maintenance of phenotype, reduced matrix synthesis, and poor integration with host tissue. We report an efficient approach for deriving mesenchymal chondroprogenitor cells from human embryonic stem cells. These cells generated tissue containing cartilage-specific matrix proteins that integrated in situ in a partial-thickness defect in ex vivo articular cartilage harvested from human arthritic joints. Given that stem cells provide a virtually inexhaustible supply of starting material and that our technique is easily scalable, cartilaginous tissue primed and grafted in this manner could be suitable for clinical translation.
Collapse
|
49
|
Influence of cartilage extracellular matrix molecules on cell phenotype and neocartilage formation. Tissue Eng Part A 2013; 20:264-74. [PMID: 23962090 DOI: 10.1089/ten.tea.2012.0618] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Interaction between chondrocytes and the cartilage extracellular matrix (ECM) is essential for maintaining the cartilage's role as a low-friction and load-bearing tissue. In this study, we examined the influence of cartilage zone-specific ECM on human articular chondrocytes (HAC) in two-dimensional and three-dimensional (3D) environments. Two culture systems were used. SYSTEM 1: HAC were cultured on cell-culture plates that had been precoated with the following ECM molecules for 7 days: decorin, biglycan, tenascin C (superficial zone), collagen type II, hyaluronan (HA) (middle and deep zones), and osteopontin (deep zone). Uncoated standard culture plates were used as controls. Expanded cells were examined for phenotypic changes using real-time polymerase chain reaction. In addition, expanded cells were placed into high-density pellet cultures for 14 days. Neocartilage formation was assessed via gene expression and histology evaluations. SYSTEM 2: HAC that were cultured on untreated plates and encapsulated in a 3D alginate scaffold were mixed with one of the zone-specific ECM molecules. Cell viability, gene expression, and histology assessments were conducted on 14-day-old tissues. In HAC monolayer culture, exposure to decorin, HA, and osteopontin increased COL2A1 and aggrecan messenger RNA (mRNA) levels compared with controls. Biglycan up-regulated aggrecan without a significant impact on COL2A1 expression; Tenascin C reduced COL2A1 expression. Neocartilage formed after preculture on tenascin C and collagen type II expressed higher COL2A1 mRNA compared with control pellets. Preculture of HAC on HA decreased both COL2A1 and aggrecan expression levels compared with controls, which was consistent with histology. Reduced proteoglycan 4 (PRG4) mRNA levels were observed in HAC pellets that had been precultured with biglycan and collagen type II. Exposing HAC to HA directly in 3D-alginate culture most effectively induced neocartilage formation, showing increased COL2A1 and aggrecan, and reduced COL1A1 compared with controls. Decorin treatments increased HAC COL2A1 mRNA levels. These data indicate that an appropriate exposure to cartilage-specific ECM proteins could be used to enhance cartilage formation and to even induce the formation of zone-specific phenotypes to improve cartilage regeneration.
Collapse
|
50
|
Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces. J Biomech 2013; 46:2778-86. [PMID: 24074941 DOI: 10.1016/j.jbiomech.2013.09.005] [Citation(s) in RCA: 167] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Revised: 07/25/2013] [Accepted: 09/05/2013] [Indexed: 11/19/2022]
Abstract
Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the prediction of tibiofemoral contact forces using a calibrated EMG-driven neuromusculoskeletal model of the knee. One participant fitted with an instrumented total knee replacement walked at a self-selected speed while medial and lateral tibiofemoral contact forces, ground reaction forces, whole-body kinematics, and lower-limb muscle activity were simultaneously measured. The combination of generic and subject-specific knee joint geometry and kinematics resulted in four different OpenSim models used to estimate muscle-tendon lengths and moment arms. The subject-specific geometric model was created from CT scans and the subject-specific knee joint kinematics representing the translation of the tibia relative to the femur was obtained from fluoroscopy. The EMG-driven model was calibrated using one walking trial, but with three different cost functions that tracked the knee flexion/extension moments with and without constraint over the estimated joint contact forces. The calibrated models then predicted the medial and lateral tibiofemoral contact forces for five other different walking trials. The use of subject-specific models with minimization of the peak tibiofemoral contact forces improved the accuracy of medial contact forces by 47% and lateral contact forces by 7%, respectively compared with the use of generic musculoskeletal model.
Collapse
|