1
|
Mechanical characterization of soft-tissue stiffness during mandibular distraction. J Craniomaxillofac Surg 2024:S1010-5182(24)00163-X. [PMID: 38796333 DOI: 10.1016/j.jcms.2024.04.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 02/25/2024] [Accepted: 04/27/2024] [Indexed: 05/28/2024] Open
Abstract
The purpose of this study was to determine the stiffness of mandibular soft tissues during mandibular distraction, from the perspective of improving distraction devices such as automated continuous distractors. Uncompleted osteotomy was performed on 11 fresh human hemimandibles via a greenstick fracture, to preserve the uplift of the internal periosteum of the mandibular corpus. In order to replicate continuous distraction, direct measurements were performed through a uniaxial quasi-static tensile test. For all specimens, linear regression was applied to the force-displacement curve for a force region of 10-20 N, and the slope extracted. The mean stiffness was estimated to be 9.12 ± 3.56 N/mm. This study is the first to measure directly the stiffness of the surrounding tissues of the human mandibular corpus, and paves the way to the design of a new generation of distractor devices.
Collapse
|
2
|
Cardiovascular Fitness and Stride Acceleration in Race-Pace Workouts for the Prediction of Performance in Thoroughbreds. Animals (Basel) 2024; 14:1342. [PMID: 38731345 PMCID: PMC11083884 DOI: 10.3390/ani14091342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 05/13/2024] Open
Abstract
In-training racehorse physiological data can be leveraged to further explore race-day performance prediction. To date, no large retrospective, observational study has analysed whether in-training speed and heart rate recovery can predict racehorse success. Speed (categorised as 'slow' to 'fast' according to the time taken to cover the last 600 m from a virtual finish line) and heart rate recovery (from gallop to 1 min after exercise) of flat racehorses (n = 485) of varying age, sex and type according to distance (e.g., sprinter, miler and stayer) were obtained using a fitness tracker from a single racing yard in Australia. Race-pace training sessions on turf comprised 'fast gallop' (n = 3418 sessions) or 'jumpout' (n = 1419). A posteriori racing information (n = 3810 races) for all 485 racehorses was extracted and combined with training data. Race performance was categorised as win/not-win or podium or not, each analysed by logistic regression. Colts (p < 0.001), stayers (p < 0.001) and being relatively fast over the last 600 m of a benchmark test in training (p < 0.008) were all predictive of race performance. Heart rate recovery after exercise (p = 0.21) and speed recorded at 600 m of a 1 km benchmark test in training (p = 0.94) were not predictive. In-training physiological data analytics used along with subjective experience may help trainers identify promising horses and improve decision-making.
Collapse
|
3
|
[Improving the accuracy of the preoperative planning of mandibular osteogenic distraction by an external custom-made device]. ANN CHIR PLAST ESTH 2023; 68:113-122. [PMID: 36670044 DOI: 10.1016/j.anplas.2022.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 12/29/2022] [Indexed: 01/20/2023]
Abstract
PURPOSE The aim of this study was to analyze the predictability of virtual surgical planning of mandibular reconstruction by osteogenic distraction (OD) with a custom-made osteogenic distraction device (DEOS) after ballistic trauma and to make recommendations to mitigate potential sources of discrepancy. METHODS This retrospective study involved 12 patients who were victims of facial mandibular ballistic trauma and were reconstructed with osteogenic distraction with a DEOS device. Postoperative images were compared to the planned situation by means of several measures made in two plans : distraction plane and frontal plane. RESULTS The mean bone loss was 54.2mm. The anteroposterior difference was systematically inferior or equal postoperatively (10.8mm). The interrami angle difference in the frontal plane was positive, with an average of 4.8°. There was a significant negative correlation in univariate analysis between the antero-posterior difference measurement and the difference of the interrami angle in distraction. CONCLUSION A significant difference between the planning and postoperative results was shown, explained by the device being too adjustable leading to the loosening of the locking screws of the device. A static analysis showed that there are significant rotational forces at the carriages, which can lead to the loosening of the locking elements. It is then proposed that the device be optimized by customization of some elements.
Collapse
|
4
|
Locomotory Profiles in Thoroughbreds: Peak Stride Length and Frequency in Training and Association with Race Outcomes. Animals (Basel) 2022; 12:ani12233269. [PMID: 36496790 PMCID: PMC9741461 DOI: 10.3390/ani12233269] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/10/2022] [Accepted: 11/21/2022] [Indexed: 11/25/2022] Open
Abstract
Racehorses competing in short (i.e., ‘sprinters’), middle- or longer-distance (i.e., ‘stayers’) flat races are assumed to have natural variation in locomotion; sprinters having an innately shorter stride than stayers. No study has objectively tested this theory. Here, racehorses (n = 421) were categorised as sprinters, milers or stayers based on known race distance (n = 3269 races). Stride parameters (peak length and frequency) of those racehorses were collected from prior race-pace training sessions on turf (n = 2689; ‘jumpout’, n = 1013), using a locomotion monitoring device. Pedigree information for all 421 racehorses was extracted to three-generations. In training, sprinters had a shorter stride of higher frequency and covered consecutive furlongs faster than stayers (p < 0.001). Relatively short or longer stride did not predict race success, but stayers had greater race success than sprinters (p < 0.001). Peak stride length and frequency were moderately heritable (h2 = 0.15 and 0.20, respectively). In conclusion, differences in stride were apparent between sprinters and stayers (e.g., shorter stride in sprinters) during routine training, even after accounting for their pedigree. Objective data on stride characteristics could supplement other less objectively obtained parameters to benefit trainers in the appropriate selection of races for each individual racehorse.
Collapse
|
5
|
Does sex of the jockey influence racehorse physiology and performance. PLoS One 2022; 17:e0273310. [PMID: 36044425 PMCID: PMC9432741 DOI: 10.1371/journal.pone.0273310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 08/07/2022] [Indexed: 11/18/2022] Open
Abstract
The racing industry is supported by a predominance of female stablehands and work riders, but few become professional jockeys. Female jockeys have recently had notable race success. No study has assessed whether the sex of the rider may subtly influence racehorse physiology to affect performance. Here, using a validated exercise tracking system (the ‘Equimetre’™) that records many physiological parameters simultaneously, this study characterised racehorse cardiovascular (heart rate, heart rate recovery) and biomechanical (stride length and frequency) parameters at various exercise intensities (slow canter to hard gallop) to address the question whether any parameter varied according to sex of the rider. A total of 530 Thoroughbreds, varying in age (2–7 years old) and sex (including geldings), from one racing yard in Australia, completed a total of 3,568 exercise sessions, monitored by a single trainer, on varying track surfaces (sand, turf, or fibre). Different work riders,103 in total (male, n = 66; female, n = 37) of which n = 43 were current or past registered professional jockeys, participated in the study. Data were analysed using analysis of variation (ANOVA) or mixed-effect models, as appropriate. Sex of the rider did not influence (P > 0.05) racehorse speed nor stride length at any training intensity. Racehorse heart rate and peak heart rate increased with training intensity (P < .001), with no difference according to sex of rider (P > 0.05). Racehorse heart rate recovery was influenced by sex of the rider, but only at the extremes of the reversed, usual training intensity on each surface (e.g. heart rate after galloping on sand was significantly lower with male riders, P = 0.03). Finally, analysis of 52,464 race results indicated a similar chance of a top-three placing for male and female jockeys. In conclusion, this study, using objectively obtained data, demonstrates for the first time no overt effect of the rider’s sex on racehorse physiology in training and performance in racing. Such data could encourage greater female participation in racing and improve access of female jockeys to better quality mounts in racing events.
Collapse
|
6
|
Repeated-Dose Toxicity, Biodistribution, and Shedding Assessments With a ChAd155 Respiratory Syncytial Virus Vaccine Candidate Evaluated in Rabbits and Rats. Int J Toxicol 2022; 41:263-275. [PMID: 35653115 DOI: 10.1177/10915818221101788] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Respiratory syncytial virus (RSV) is a leading cause of acute lower respiratory tract infections (LRTI) in infants, and toddlers and vaccines are not yet available. A pediatric RSV vaccine (ChAd155-RSV) is being developed to protect infants against RSV disease. The ChAd155-RSV vaccine consists of a recombinant replication-deficient chimpanzee-derived adenovirus (ChAd) group C vector engineered to express the RSV antigens F, N, and M2-1. The local and systemic effects of three bi-weekly intramuscular injections of the ChAd155-RSV vaccine was tested in a repeated-dose toxicity study in rabbits. After three intramuscular doses, the ChAd155-RSV vaccine was considered well-tolerated. Changes due to the vaccine-elicited inflammatory reaction/immune response were observed along with transient decreases in platelet count without physiological consequences, already reported for other adenovirus-based vaccines. In addition, the biodistribution and shedding of ChAd155-RSV were also characterized in two studies in rats. The distribution and persistence of the ChAd155-RSV vaccine candidate was consistent with other similar adenovector-based vaccines, with quantifiable levels of ChAd155-RSV observed at the injection site (muscle) and the draining lymph nodes up to 69 days post administration. The shedding results demonstrated that ChAd155-RSV was generally not detectable in any secretions or excreta samples. In conclusion, the ChAd155-RSV vaccine was well-tolerated locally and systemically.
Collapse
|
7
|
La santé, une affaire d’État. BULLETIN DE L'ACADÉMIE NATIONALE DE MÉDECINE 2022; 206:477-478. [PMID: 35233107 PMCID: PMC8872702 DOI: 10.1016/j.banm.2022.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
8
|
Cardiovascular and locomotory parameters during training in Thoroughbred racehorses: a multi-national study. COMPARATIVE EXERCISE PHYSIOLOGY 2022. [DOI: 10.3920/cep210037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Studies assessing concurrent speed, cardiovascular physiology and biomechanical parameters in racehorses during training have been rarely reported, mostly due to a lack of available comprehensive technology. Here, using a validated device (the ‘Equimetre’™) that records all parameters simultaneously, we report the effect of increased training speed and thus intensity, from slow canter to hard gallop, on racehorse heart rate, heart rate recovery and on biomechanical parameters, such as stride length and frequency. We also demonstrate the effects of varying track surface, horse age and sex. Cohorts comprised a total of 509 Thoroughbred racehorses in-training in either Australia or France, completing a total of 1,124 and 6,016 training sessions, respectively. Horses varied by age (2-9 years old) and sex (including geldings) and were trained by either a single trainer (Australia) or two trainers (France); both using multiple training centres that varied by track surface (sand, turf or fibre). Data were analysed using Analysis of Variation (ANOVA) or linear mixed-effect models as appropriate. Racehorses increased speed predominantly by an increment in stride length, then frequency, both of which varied according to track surface (shorter stride on sand; P<0.001). Cardiovascular parameters (peak, and recovery of, heart rate) increased with training intensity, but not linearly (Ptrend<0.001). Older horses recorded lower heart rate at 15 mins after training (P=0.002), often due to lower achieved peak heart rate at most training intensities (P<0.001 for the cohort in Australia). In conclusion, this immersive field study demonstrates the value of technology for recording physiological and biomechanical parameters of racehorses-in-training. The data could inform trainers, jockeys and owners on aspects of individual racehorse health, welfare and suitability for certain races.
Collapse
|
9
|
Validation of an equine fitness tracker: ECG quality and arrhythmia detection. Equine Vet J 2022; 55:336-343. [PMID: 35138653 PMCID: PMC10078706 DOI: 10.1111/evj.13565] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 01/16/2022] [Accepted: 02/02/2022] [Indexed: 12/01/2022]
Abstract
BACKGROUND Cardiac arrhythmias in exercising horses are the focus of much interest, both in terms of what is considered normal and potential associations with poor performance and sudden cardiac death. One barrier to performing large-scale studies is the lack of an easily applicable device, to allow recording of large numbers of high-quality exercising electrocardiograms (ECGs). The EquimetreTM is a new wearable device which records a single lead ECG, amongst other parameters. Validation of such wearable devices is essential before further studies are undertaken. OBJECTIVES To evaluate the quality of ECG using the EquimetreTM and compare arrhythmia detection during exercise with the reference TelevetTM system. STUDY DESIGN Prospective blinded clinical study. METHODS Simultaneous ECGs were recorded with both systems in 49 healthy horses during exercise. High intensity exercise (>40km/h) was performed by 29 racehorses, and lower intensity exercise for the remainder of the racehorses and show jumpers. Tracings were excluded if >10% artefact was present (duration of artefact relative to duration of exercise). For included ECGs, the duration of artefact was recorded and compared. ECGs were evaluated using Kubios premium software. Arrhythmia detection (yes/no) and arrhythmia classification (sinus arrhythmia, narrow complex of similar morphology to the sinus complexes or wide complex with a different morphology) were compared using Cohen's Kappa coefficient. RESULTS Nine TelevetTM ECGs and 3 EquimetreTM ECGs were excluded due to artefact >10%. TelevetTM ECGs included significantly more artefact during exercise than EquimetreTM ECGs (5% vs. 0.25% p<0.001). Arrhythmia analysis was performed on 38 horses' paired ECGs. The Kappa coefficient was excellent for arrhythmia detection (K=0.97) and arrhythmia classification (K=0.93). MAIN LIMITATIONS Relatively low numbers of horses with arrhythmias (n=21) were included. The ECG recordings only provided one lead, making arrhythmia classification challenging in some cases. CONCLUSIONS The Equimetre device provides a reliable ECG for arrhythmia detection during exercise. This system may be useful clinically and for future large-scale investigations into the occurrence and significance of exercising arrhythmias.
Collapse
|
10
|
Fully automatic segmentation of craniomaxillofacial CT scans for computer-assisted orthognathic surgery planning using the nnU-Net framework. Eur Radiol 2022; 32:3639-3648. [PMID: 35037088 DOI: 10.1007/s00330-021-08455-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 09/27/2021] [Accepted: 11/01/2021] [Indexed: 01/06/2023]
Abstract
OBJECTIVES To evaluate the performance of the nnU-Net open-source deep learning framework for automatic multi-task segmentation of craniomaxillofacial (CMF) structures in CT scans obtained for computer-assisted orthognathic surgery. METHODS Four hundred and fifty-three consecutive patients having undergone high-resolution CT scans before orthognathic surgery were randomly distributed among a training/validation cohort (n = 300) and a testing cohort (n = 153). The ground truth segmentations were generated by 2 operators following an industry-certified procedure for use in computer-assisted surgical planning and personalized implant manufacturing. Model performance was assessed by comparing model predictions with ground truth segmentations. Examination of 45 CT scans by an industry expert provided additional evaluation. The model's generalizability was tested on a publicly available dataset of 10 CT scans with ground truth segmentation of the mandible. RESULTS In the test cohort, mean volumetric Dice similarity coefficient (vDSC) and surface Dice similarity coefficient at 1 mm (sDSC) were 0.96 and 0.97 for the upper skull, 0.94 and 0.98 for the mandible, 0.95 and 0.99 for the upper teeth, 0.94 and 0.99 for the lower teeth, and 0.82 and 0.98 for the mandibular canal. Industry expert segmentation approval rates were 93% for the mandible, 89% for the mandibular canal, 82% for the upper skull, 69% for the upper teeth, and 58% for the lower teeth. CONCLUSION While additional efforts are required for the segmentation of dental apices, our results demonstrated the model's reliability in terms of fully automatic segmentation of preoperative orthognathic CT scans. KEY POINTS • The nnU-Net deep learning framework can be trained out-of-the-box to provide robust fully automatic multi-task segmentation of CT scans performed for computer-assisted orthognathic surgery planning. • The clinical viability of the trained nnU-Net model is shown on a challenging test dataset of 153 CT scans randomly selected from clinical practice, showing metallic artifacts and diverse anatomical deformities. • Commonly used biomedical segmentation evaluation metrics (volumetric and surface Dice similarity coefficient) do not always match industry expert evaluation in the case of more demanding clinical applications.
Collapse
|
11
|
Validation of an equine fitness tracker: heart rate and heart rate variability. COMPARATIVE EXERCISE PHYSIOLOGY 2021. [DOI: 10.3920/cep200028] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The adoption of fitness tracker devices to monitor training in the equine market is in full expansion. However, the validity of most of these devices has not been assessed. The aim of this study was to examine the validity of heart rate (HR) and heart rate variability (HRV) measurements during high-intensity exercise by an integrated equine fitness tracker with an electrocardiogram (ECG) (Equimetre) in comparison to an ECG device (Televet). Twenty Thoroughbred racehorses were equipped with the two devices and completed a training session at the track. Data from 18 horses was readable to be analysed. Equimetre HR was compared to Televet HR derived from the corrected Televet ECG. HRV parameters were computed in a dedicated software (Kubios) on uncorrected and manually corrected ECG from both devices, and compared to the Televet corrected data. The HR was recorded on the entire training session and HRV parameters were calculated during the exercise and recovery periods. A strong correlation between the Equimetre HR and Televet HR on corrected data was found (Pearson correlation: r=0.992, P<0.001; root mean square error = 4.06 bpm). For HRV, the correlation was good for all parameters when comparing corrected Equimetre to corrected Televet data (Lin’s coefficient = 0.998). When comparing data obtained from uncorrected Equimetre data to the corrected Televet data, the correlation for HR was still good (Lin’s coefficient = 0.995) but the correlation for all HRV parameters was poor, except for the triangular index (Lin’s coefficient = 0.995). However, correlation between the uncorrected Televet HRV data and the corrected Televet data was equally poor (Lin’s coefficient <0.9). In conclusion, the integrated equine fitness tracker Equimetre satisfies validity criteria for HR monitoring in horses during high intensity exercise. When using corrected ECG data, it provides accurate HRV parameters as well.
Collapse
|
12
|
Repair of sinus venosus defects with partial anomalous pulmonary venous connection in adult: Four surgical procedures for a large armamentarium. ARCHIVES OF CARDIOVASCULAR DISEASES SUPPLEMENTS 2021. [DOI: 10.1016/j.acvdsp.2020.10.300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
13
|
Confinée mais mobilisée, l’Académie nationale de médecine au temps de la Covid-19. BULLETIN DE L'ACADÉMIE NATIONALE DE MÉDECINE 2020; 204:634-635. [PMID: 32834022 PMCID: PMC7271851 DOI: 10.1016/j.banm.2020.05.109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Accepted: 05/30/2020] [Indexed: 12/02/2022]
|
14
|
Nonclinical safety assessment of repeated administration and biodistribution of a novel rabies self-amplifying mRNA vaccine in rats. Regul Toxicol Pharmacol 2020; 113:104648. [PMID: 32240713 DOI: 10.1016/j.yrtph.2020.104648] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 03/09/2020] [Accepted: 03/23/2020] [Indexed: 11/25/2022]
Abstract
The novel self-amplifying mRNA (SAM) technology for vaccines consists of an engineered replication-deficient alphavirus genome encoding an RNA-dependent RNA polymerase and the gene of the target antigen. To validate the concept, the rabies glycoprotein G was chosen as antigen. The delivery system for this vaccine was a cationic nanoemulsion. To characterize the local tolerance, potential systemic toxicity and biodistribution of this vaccine, two nonclinical studies were performed. In the repeated dose toxicity study, the SAM vaccine was administered intramuscularly to rats on four occasions at two-week intervals followed by a four-week recovery period. SAM-related changes consisted of a transient increase in neutrophil count, alpha-2-macroglobulin and fibrinogen levels. Transient aspartate aminotransferase and alanine aminotransferase increases were also noted in females only. At necropsy, observations related to the elicited inflammatory reaction, such as enlargement of the draining lymph nodes were observed that were almost fully reversible by the end of the recovery period. In the biodistribution study, rats received a single intramuscular injection of SAM vaccine and then were followed until Day 60. Rabies RNA was found at the injection sites and in the draining lymph nodes one day after administration, then generally decreased in these tissues but remained detectable up to Day 60. Rabies RNA was also transiently found in blood, lungs, spleen and liver. No microscopic changes in the brain and spinal cord were recorded. In conclusion, these results showed that the rabies SAM vaccine was well-tolerated by the animals and supported the clinical development program.
Collapse
|
15
|
Towards an osteogenic periosteal free flap for mandibular radionecrosis. Int J Oral Maxillofac Surg 2019. [DOI: 10.1016/j.ijom.2019.03.436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
16
|
Importantes disparités entre les méthodes de mesure de la testostérone par spectrométrie de masse et par immunodosage en électrochemiluminescence chez les patients castrés atteints d’un cancer de la prostate : implications cliniques. Prog Urol 2018. [DOI: 10.1016/j.purol.2018.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
17
|
Comparative finite element analysis of skull mechanical properties following parietal bone graft harvesting in adults. J Craniomaxillofac Surg 2018; 46:329-337. [DOI: 10.1016/j.jcms.2017.11.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Revised: 10/29/2017] [Accepted: 11/20/2017] [Indexed: 10/18/2022] Open
|
18
|
The OC43 human coronavirus envelope protein is critical for infectious virus production and propagation in neuronal cells and is a determinant of neurovirulence and CNS pathology. Virology 2018; 515:134-149. [PMID: 29287230 PMCID: PMC7118982 DOI: 10.1016/j.virol.2017.12.023] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 12/08/2017] [Accepted: 12/20/2017] [Indexed: 12/19/2022]
Abstract
The OC43 strain of human coronavirus (HCoV-OC43) is an ubiquitous respiratory tract pathogen possessing neurotropic capacities. Coronavirus structural envelope (E) protein possesses specific motifs involved in protein-protein interaction or in homo-oligomeric ion channel formation, which are known to play various roles including in virion morphology/assembly and in cell response to infection and/or virulence. Making use of recombinant viruses either devoid of the E protein or harboring mutations either in putative transmembrane domain or PDZ-binding motif, we demonstrated that a fully functional HCoV-OC43 E protein is first needed for optimal production of recombinant infectious viruses. Furthermore, HCoV-OC43 infection of human epithelial and neuronal cell lines, of mixed murine primary cultures from the central nervous system and of mouse central nervous system showed that the E protein is critical for efficient and optimal virus replication and propagation, and thereby for neurovirulence.
Collapse
|
19
|
|
20
|
Bezafibrate Improves Insulin Sensitivity and Metabolic Flexibility in STZ-Induced Diabetic Mice. Diabetes 2016; 65:2540-52. [PMID: 27284107 DOI: 10.2337/db15-1670] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 05/25/2016] [Indexed: 11/13/2022]
Abstract
Bezafibrate (BEZ), a pan activator of peroxisome proliferator-activated receptors (PPARs), has been generally used to treat hyperlipidemia for decades. Clinical trials with type 2 diabetes patients indicated that BEZ also has beneficial effects on glucose metabolism, although the underlying mechanisms of these effects remain elusive. Even less is known about a potential role for BEZ in treating type 1 diabetes. Here we show that BEZ markedly improves hyperglycemia and glucose and insulin tolerance in mice with streptozotocin (STZ)-induced diabetes, an insulin-deficient mouse model of type 1 diabetes. BEZ treatment of STZ mice significantly suppressed the hepatic expression of genes that are annotated in inflammatory processes, whereas the expression of PPAR and insulin target gene transcripts was increased. Furthermore, BEZ-treated mice also exhibited improved metabolic flexibility as well as an enhanced mitochondrial mass and function in the liver. Finally, we show that the number of pancreatic islets and the area of insulin-positive cells tended to be higher in BEZ-treated mice. Our data suggest that BEZ may improve impaired glucose metabolism by augmenting hepatic mitochondrial performance, suppressing hepatic inflammatory pathways, and improving insulin sensitivity and metabolic flexibility. Thus, BEZ treatment might also be useful for patients with impaired glucose tolerance or diabetes.
Collapse
|
21
|
Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep. J Mech Behav Biomed Mater 2016; 59:484-496. [DOI: 10.1016/j.jmbbm.2016.02.036] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2015] [Revised: 02/21/2016] [Accepted: 02/28/2016] [Indexed: 11/30/2022]
|
22
|
Abstract
The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Resonance Images, which provide a personalized model in lying position. This study proposed an original two steps method to access a subject-specific musculo-skeletal model in 30 min, which is based solely on biplanar X-Rays. First, the subject-specific 3D geometry of bones and skin envelopes were reconstructed from biplanar X-Rays radiography. Then, 2200 corresponding control points were identified between a reference model and the subject-specific X-Rays model. Finally, the shape of 21 lower limb muscles was estimated using a non-linear transformation between the control points in order to fit the muscle shape of the reference model to the X-Rays model. Twelfth musculo-skeletal models were reconstructed and compared to their reference. The muscle volume was not accurately estimated with a standard deviation (SD) ranging from 10 to 68%. However, this method provided an accurate estimation the muscle line of action with a SD of the length difference lower than 2% and a positioning error lower than 20 mm. The moment arm was also well estimated with SD lower than 15% for most muscle, which was significantly better than scaled-generic model for most muscle. This method open the way to a quick modeling method for gait analysis based on biplanar radiography.
Collapse
|
23
|
Reliable femoral frame construction based on MRI dedicated to muscles position follow-up. Med Biol Eng Comput 2015; 53:921-8. [DOI: 10.1007/s11517-015-1302-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Accepted: 04/27/2015] [Indexed: 11/30/2022]
|
24
|
Health co-benefits and household preferences for reducing greenhouse gas emission in Europe. Eur J Public Health 2015. [DOI: 10.1093/eurpub/ckv171.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
25
|
Alcohol, cigarette, and illegal substance consumption among medical students: a cross-sectional survey. Workplace Health Saf 2015; 63:54-63. [PMID: 25881656 DOI: 10.1177/2165079915570917] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study investigated addictive substance use by French medical students. A cross-sectional survey was distributed to 255 participants randomly selected from 1,021 second- to sixth-year medical students. Questionnaires were self-administered and included questions on sociodemographic characteristics, mental health, and alcohol (The Alcohol Use Disorders Identification Test [AUDIT test]), tobacco (Fagerstrom test), and illegal substance consumption (Cannabis Abuse Screening Test [CAST test]). The AUDIT scores indicated that 11% of the study participants were at risk for addiction and 21% were high-risk users. Tobacco dependence was strong or very strong for 12% of the participants. The CAST score showed that 5% of cannabis users needed health care services. Cannabis users were also more likely than non-users to fail their medical school examinations (89% vs. 39%, p<.01). One quarter of medical student participants (n=41) had used other illegal drugs, and 10% of study participants had considered committing suicide during the previous 12 months. Psychoactive substance consumption by French medical students requires preventive measures, screening, and health care services.
Collapse
|
26
|
Reliable protocol for shear wave elastography of lower limb muscles at rest and during passive stretching. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2284-2291. [PMID: 26129731 DOI: 10.1016/j.ultrasmedbio.2015.04.020] [Citation(s) in RCA: 86] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 01/26/2015] [Accepted: 04/27/2015] [Indexed: 06/04/2023]
Abstract
Development of shear wave elastography gave access to non-invasive muscle stiffness assessment in vivo. The aim of the present study was to define a measurement protocol to be used in clinical routine for quantifying the shear modulus of lower limb muscles. Four positions were defined to evaluate shear modulus in 10 healthy subjects: parallel to the fibers, in the anterior and posterior aspects of the lower limb, at rest and during passive stretching. Reliability was first evaluated on two muscles by three operators; these measurements were repeated six times. Then, measurement reliability was compared in 11 muscles by two operators; these measurements were repeated three times. Reproducibility of shear modulus was 0.48 kPa and repeatability was 0.41 kPa, with all muscles pooled. Position did not significantly influence reliability. Shear wave elastography appeared to be an appropriate and reliable tool to evaluate the shear modulus of lower limb muscles with the proposed protocol.
Collapse
|
27
|
Co-occurrence and reproductive synchrony do not ensure hybridization between an alien tunicate and its interfertile native congener. Evol Ecol 2015. [DOI: 10.1007/s10682-015-9788-1] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
28
|
What is the recommended size of a Volume of Interest for cancellous bone? A skeleton-based study. Comput Methods Biomech Biomed Engin 2015; 18 Suppl 1:1932-3. [DOI: 10.1080/10255842.2015.1069574] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
29
|
Fracture characterization in cancellous bone specimens via surface difference evaluation of 3D registered pre- and post-compression micro-CT scans. Comput Methods Biomech Biomed Engin 2015; 18 Suppl 1:2030-1. [DOI: 10.1080/10255842.2015.1069608] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
30
|
Lumbar annulus fibrosus biomechanical characterization in healthy children by ultrasound shear wave elastography. Eur Radiol 2015. [PMID: 26198667 DOI: 10.1007/s00330-015-3911-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVES Intervertebral disc (IVD) is key to spine biomechanics, and it is often involved in the cascade leading to spinal deformities such as idiopathic scoliosis, especially during the growth spurt. Recent progress in elastography techniques allows access to non-invasive measurement of cervical IVD in adults; the aim of this study was to determine the feasibility and reliability of shear wave elastography in healthy children lumbar IVD. METHODS Elastography measurements were performed in 31 healthy children (6-17 years old), in the annulus fibrosus and in the transverse plane of L5-S1 or L4-L5 IVD. Reliability was determined by three experienced operators repeating measurements. RESULTS Average shear wave speed in IVD was 2.9 ± 0.5 m/s; no significant correlations were observed with sex, age or body morphology. Intra-operator repeatability was 5.0 % while inter-operator reproducibility was 6.2 %. Intraclass correlation coefficient was higher than 0.9 for each operator. CONCLUSIONS Feasibility and reliability of IVD shear wave elastography were demonstrated. The measurement protocol is compatible with clinical routine and the results show the method's potential to give an insight into spine deformity progression and early detection. KEY POINTS • Intervertebral disc mechanical properties are key to spine biomechanics • Feasibility of shear wave elastography in children lumbar disc was assessed • Measurement was fast and reliable • Elastography could represent a novel biomarker for spine pathologies.
Collapse
|
31
|
Three-dimensional parabolic equation model for low frequency sound propagation in irregular urban canyons. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:310-320. [PMID: 25618062 DOI: 10.1121/1.4904700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A three-dimensional wide-angle parabolic equation (3DPE) is used to model low frequency sound propagation in irregular urban canyons at low computational cost. This one-way wave equation is solved using the Alternating Direction Implicit method. A finite difference scheme adapted to the geometry of the urban environment is then developed. Abrupt variations of the street width are treated as a single scattering problem using the Kirchhoff approximation. Numerical results are compared with experimental data obtained on a scale model of a street. Comparisons show the ability of the 3DPE model to provide reliable transmitted fields even for large irregularities.
Collapse
|
32
|
In vivo cervical intervertebral disc characterisation by elastography. Comput Methods Biomech Biomed Engin 2014; 17 Suppl 1:120-1. [PMID: 25074194 DOI: 10.1080/10255842.2014.931515] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
33
|
Comparison of two MRI sequences for subject-specific 3D thigh muscle reconstruction. Comput Methods Biomech Biomed Engin 2014; 17 Suppl 1:136-7. [DOI: 10.1080/10255842.2014.931546] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
34
|
Intervertebral disc characterization by shear wave elastography: An in vitro preliminary study. Proc Inst Mech Eng H 2014; 228:607-615. [DOI: 10.1177/0954411914540279] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Patient-specific numerical simulation of the spine is a useful tool both in clinic and research. While geometrical personalization of the spine is no more an issue, thanks to recent technological advances, non-invasive personalization of soft tissue’s mechanical properties remains a challenge. Ultrasound elastography is a relatively recent measurement technique allowing the evaluation of soft tissue’s elastic modulus through the measurement of shear wave speed. The aim of this study was to determine the feasibility of elastographic measurements in intervertebral disc. An in vitro approach was chosen to test the hypothesis that shear wave speed can be used to evaluate intervertebral disc mechanical properties and to assess measurement repeatability. In total, 11 oxtail intervertebral discs were tested in compression to determine their stiffness and apparent elastic modulus at rest and at 400 N. Elastographic measurements were performed in these two conditions and compared to these mechanical parameters. The protocol was repeated six times to determine elastographic measurement repeatability. Average shear wave speed over all samples was 5.3 ± 1.0 m/s, with a repeatability of 7% at rest and 4.6% at 400 N; stiffness and apparent elastic modulus were 266.3 ± 70.5 N/mm and 5.4 ± 1.1 MPa at rest, respectively, while at 400 N they were 781.0 ± 153.8 N/mm and 13.2 ± 2.4 MPa, respectively. Correlations were found between elastographic measurements and intervertebral disc mechanical properties; these preliminary results are promising for further in vivo application.
Collapse
|
35
|
Reduced Modal Modelling of Time-Domain Propagation in Complex Waveguide Networks. ACTA ACUST UNITED AC 2014. [DOI: 10.3813/aaa.918718] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
36
|
Skeletal muscle segmentation from MRI dataset using a model-based approach. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION 2014. [DOI: 10.1080/21681163.2013.855146] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
37
|
|
38
|
Reliable femoral frame construction on MRI images. Comput Methods Biomech Biomed Engin 2013; 16 Suppl 1:228-30. [DOI: 10.1080/10255842.2013.815891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
39
|
[Clinical case of the month. An unusual sepsis]. REVUE MEDICALE DE LIEGE 2013; 68:387-390. [PMID: 24053095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Lemierre's syndrome is a rare, but significant pathology to recognize. It most often affects young patients in good health; a late diagnosis can be fatal. It consists in an anaerobic septicemia (usually, Fusobacterium necrophorum) originating from a suppurative thrombophlebitis of the internal jugular vein. Infection occurs during a common sore throat and spreads by contiguity. The clinical presentation is a sepsis with pulmonary embolisations, but other sites of dissemination can also occur. Treatment consists of prolonged intravenous antibiotherapy associated with supportive therapy, if needed. Anticoagulation remains controversial. The outcome is favorable in most cases provided diagnosis and treatment are early; mortality however remains significant, around 5%.
Collapse
|
40
|
Intervertebral disc characterisation by elastography: a preliminary study. Comput Methods Biomech Biomed Engin 2013; 16 Suppl 1:275-7. [DOI: 10.1080/10255842.2013.815853] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
41
|
|
42
|
In vivo study of human mandibular distraction osteogenesis. Part II: Determination of callus mechanical properties. Acta Bioeng Biomech 2013; 15:11-18. [PMID: 23957392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Distraction Osteogenesis (DO) is a surgical technique used to reconstruct bone defects. To improve the current treatment protocols, the knowledge of the mechanical properties of the bone regenerate is of major interest. The aim of this study, constituting the second part of our paper previously published in Acta of Bioengineering and Biomechanics, was to identify the elastic and viscous properties of bone callus. This is done in the case of a mandibular DO by analyzing the experimental measurements of the forces imposed on bone regenerate by a distraction device. The bone transport forces were evaluated thanks to strain gauges glued on the distraction device. A rheological model describing the callus constitutive behavior was developed and the material constants involved were identified. The time-dependent character of the bone regenerate mechanical behavior was confirmed. The viscous response of the mesenchymal tissue was described by two characteristic times. The first one describing the viscoelastic callus behavior was estimated to be 140 seconds and the second one representing the permanent bone callus lengthening was evaluated to be 5646 seconds. An average value of 0.35 MPa for the regenerate Young's modulus was deduced. The elastic properties of mesenchymal tissue found are in agreement with the rare data available in the literature.
Collapse
|
43
|
CCL28 induces mucosal homing of HIV-1-specific IgA-secreting plasma cells in mice immunized with HIV-1 Virus-like Particles. Retrovirology 2012. [PMCID: PMC3441582 DOI: 10.1186/1742-4690-9-s2-p19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
|
44
|
The framework convention on tobacco control's original sin. Public Health 2012; 126:904; author reply 905. [PMID: 22770739 DOI: 10.1016/j.puhe.2012.02.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2012] [Accepted: 02/15/2012] [Indexed: 10/28/2022]
|
45
|
IMPROVED METHOD FOR SEGMENTATION OF MUSCLES FROM MRI IMAGES. J Biomech 2012. [DOI: 10.1016/s0021-9290(12)70500-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
46
|
Development and mechanical characterization of porous titanium bone substitutes. J Mech Behav Biomed Mater 2012; 9:34-44. [DOI: 10.1016/j.jmbbm.2012.01.008] [Citation(s) in RCA: 124] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2011] [Revised: 01/03/2012] [Accepted: 01/14/2012] [Indexed: 11/27/2022]
|
47
|
Moisture-insensitive polycarbosilane films with superior mechanical properties. ACS APPLIED MATERIALS & INTERFACES 2012; 4:2659-2663. [PMID: 22500550 DOI: 10.1021/am300312y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report cross-linked polycarbosilane (CLPCS) films with superior mechanical properties and insensitivity to moisture. CLPCS are prepared by spin-coating and thermal curing of hexylene-bridged disilacyclobutane (DSCB) rings. The resulting films are siloxane-free and hydrophobic, and present good thermal stability and a low dielectric constant of k = 2.5 without the presence of supermicropores and mesopores. The elastic stiffness and fracture resistance of the films substantially exceed those of traditional porous organosilicate glasses because of their unique molecular structure. Moreover, the films show a remarkable insensitivity to moisture attack, which cannot be achieved by traditional organosilicate glasses containing siloxane bonds. These advantages make the films promising candidates for replacing traditional organosilicate glasses currently used in numerous applications, and for use in emerging nanoscience and energy applications that need protection from moisture and harsh environments.
Collapse
|
48
|
Re: Prostate Cancer Screening in the Randomized Prostate, Lung, Colorectal, and Ovarian Cancer Screening Trial: Mortality Results after 13 Years of Follow-up. J Natl Cancer Inst 2012; 104:793; author reply 793-4. [DOI: 10.1093/jnci/djs205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
49
|
In vivo study of human mandibular distraction osteogenesis. Part I: bone transport force determination. Acta Bioeng Biomech 2012; 14:3-14. [PMID: 23394065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Distraction Osteogenesis (DO) is a surgical technique used to reconstruct bone defects. The evolution of forces acting during DO is known to be strongly influencing the clinical issue of the treatment. The aim of this study was to determine experimentally the time-dependent forces imposed on bone regenerate by a distraction device in the case of a mandibular DO consecutive to a gunshot wound. To evaluate the bone transport forces, some fixing pins of the distraction device were equipped with strain gauges. Measurements were done during the first weeks of the treatment. An equilibrium analysis was achieved to determine the forces acting in bone regenerate from strains in the pins. Those quantities evolved during the records approximately from 5 N to 3-4 N and 2 N to 0-0.3 N for the tension and shear forces, respectively, depending on the record duration. For the longest record, the callus lengthening reached 0.17 mm during 75 minutes. This decrease of force and simultaneous callus extension can be attributed to the viscosity of regenerate and the elastic energy release of the device. Essential data were obtained concerning forces, extension and their evolution during mandibular DO. The low force level obtained was attributed to the absence of resistance of the soft tissues in the case of ballistic trauma restoration.
Collapse
|
50
|
[Autologous tissue engineering by means of distraction osteogenesis: Biomechanical considerations]. ACTA ACUST UNITED AC 2011; 112:222-8. [PMID: 21794888 DOI: 10.1016/j.stomax.2011.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Tissue engineering consists in producing functional replacement tissue. Distraction osteogenesis is a tissue engineering technique that uses the mechanical environment of cells to induce tissue regeneration, without need for exogenous biochemical factors. A better understanding of the optimal mechanical conditions of distraction callus stretching may reduce the duration, discomfort, and even social impact of distraction protocols, and complications and failures. We present the current state of knowledge in this field by addressing the fundamentals of elongating bone tissue biomechanics, the influence of rhythm and rate of distraction, and that of vectors and stability. Finally, we present the innovations currently studied, which may modify our clinical protocol in the short term.
Collapse
|