1
|
Optical coherence tomography-guided Brillouin microscopy highlights regional tissue stiffness differences during anterior neural tube closure in the Mthfd1l murine mutant. Development 2024; 151:dev202475. [PMID: 38682273 DOI: 10.1242/dev.202475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 04/18/2024] [Indexed: 05/01/2024]
Abstract
Neurulation is a highly synchronized biomechanical process leading to the formation of the brain and spinal cord, and its failure leads to neural tube defects (NTDs). Although we are rapidly learning the genetic mechanisms underlying NTDs, the biomechanical aspects are largely unknown. To understand the correlation between NTDs and tissue stiffness during neural tube closure (NTC), we imaged an NTD murine model using optical coherence tomography (OCT), Brillouin microscopy and confocal fluorescence microscopy. Here, we associate structural information from OCT with local stiffness from the Brillouin signal of embryos undergoing neurulation. The stiffness of neuroepithelial tissues in Mthfd1l null embryos was significantly lower than that of wild-type embryos. Additionally, exogenous formate supplementation improved tissue stiffness and gross embryonic morphology in nullizygous and heterozygous embryos. Our results demonstrate the significance of proper tissue stiffness in normal NTC and pave the way for future studies on the mechanobiology of normal and abnormal embryonic development.
Collapse
|
2
|
Tunable Macroscopic Alignment of Self-Assembling Peptide Nanofibers. ACS NANO 2024; 18:12477-12488. [PMID: 38699877 DOI: 10.1021/acsnano.4c02030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
Progress in the design and synthesis of nanostructured self-assembling systems has facilitated the realization of numerous nanoscale geometries, including fibers, ribbons, and sheets. A key challenge has been achieving control across multiple length scales and creating macroscopic structures with nanoscale organization. Here, we present a facile extrusion-based fabrication method to produce anisotropic, nanofibrous hydrogels using self-assembling peptides. The application of shear force coinciding with ion-triggered gelation is used to kinetically trap supramolecular nanofibers into aligned, hierarchical macrostructures. Further, we demonstrate the ability to tune the nanostructure of macroscopic hydrogels through modulating phosphate buffer concentration during peptide self-assembly. In addition, increases in the nanostructural anisotropy of fabricated hydrogels are found to enhance their strength and stiffness under hydrated conditions. To demonstrate their utility as an extracellular matrix-mimetic biomaterial, aligned nanofibrous hydrogels are used to guide directional spreading of multiple cell types, but strikingly, increased matrix alignment is not always correlated with increased cellular alignment. Nanoscale observations reveal differences in cell-matrix interactions between variably aligned scaffolds and implicate the need for mechanical coupling for cells to understand nanofibrous alignment cues. In total, innovations in the supramolecular engineering of self-assembling peptides allow us to decouple nanostructure from macrostructure and generate a gradient of anisotropic nanofibrous hydrogels. We anticipate that control of architecture at multiple length scales will be critical for a variety of applications, including the bottom-up tissue engineering explored here.
Collapse
|
3
|
Acute alcohol consumption modulates corneal biomechanical properties as revealed by optical coherence elastography. J Biomech 2024; 169:112155. [PMID: 38761746 DOI: 10.1016/j.jbiomech.2024.112155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 05/03/2024] [Accepted: 05/14/2024] [Indexed: 05/20/2024]
Abstract
Acute alcohol ingestion has been found to impact visual functions, including eye movement, but its effects on corneal biomechanical properties remain unclear. This study aimed to investigate the influence of acute alcohol consumption on corneal biomechanical properties using optical coherence elastography (OCE). An air-coupled ultrasound transducer induced elastic waves in mice corneas in vivo, and a high-resolution phase-sensitive optical coherence tomography (OCT) system tracked the mechanical waves to quantify the elastic wave speed. In vivo measurements were performed on three groups of age- and gender-matched mice: control, placebo (administered saline), and alcohol (administered ethanol) groups. Longitudinal measurements were conducted over a one-hour period to assess acute temporal changes in wave speeds, which are associated with inherent biomechanical properties of the cornea. The results showed a significant decrease in wave speed for the alcohol group after 10 min of ingestion in comparison to pre-ingestion values (p = 0.0096), whereas the temporal wave speed changes for the placebo group were statistically insignificant (p = 0.076). In contrast, the control group showed no significant changes in elastic wave speed and corneal thickness. Furthermore, a significant difference was observed between the wave speeds of the placebo and alcohol groups at each measurement time point between 10 and 50 min (p < 0.05), though both groups exhibited a similar trend in corneal thickness change. The findings of this study have important implications for clinical assessments and research in corneal disorders, highlighting the potential of OCE as a valuable tool for evaluating such changes.
Collapse
|
4
|
Noninvasive Tracking of Embryonic Cardiac Dynamics and Development with Volumetric Optoacoustic Spectroscopy. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2400089. [PMID: 38526147 DOI: 10.1002/advs.202400089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/29/2024] [Indexed: 03/26/2024]
Abstract
Noninvasive monitoring of cardiac development can potentially prevent cardiac anomalies in adulthood. Mouse models provide unique opportunities to study cardiac development and disease in mammals. However, high-resolution noninvasive functional analyses of murine embryonic cardiac models are challenging because of the small size and fast volumetric motion of the embryonic heart, which is deeply embedded inside the uterus. In this study, a real time volumetric optoacoustic spectroscopy (VOS) platform for whole-heart visualization with high spatial (100 µm) and temporal (10 ms) resolutions is developed. Embryonic heart development on gestational days (GDs) 14.5-17.5 and quantify cardiac dynamics using time-lapse-4D image data of the heart is followed. Additionally, spectroscopic recordings enable the quantification of the blood oxygenation status in heart chambers in a label-free and noninvasive manner. This technology introduces new possibilities for high-resolution quantification of embryonic heart function at different gestational stages in mammalian models, offering an invaluable noninvasive method for developmental biology.
Collapse
|
5
|
Disruption of Fuz in mouse embryos generates hypoplastic hindbrain development and reduced cranial nerve ganglia. Dev Dyn 2024. [PMID: 38501709 DOI: 10.1002/dvdy.702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/07/2024] [Accepted: 02/20/2024] [Indexed: 03/20/2024] Open
Abstract
BACKGROUND The brain and spinal cord formation is initiated in the earliest stages of mammalian pregnancy in a highly organized process known as neurulation. Environmental or genetic interferences can impair neurulation, resulting in clinically significant birth defects known collectively as neural tube defects. The Fuz gene encodes a subunit of the CPLANE complex, a macromolecular planar polarity effector required for ciliogenesis. Ablation of Fuz in mouse embryos results in exencephaly and spina bifida, including dysmorphic craniofacial structures due to defective cilia formation and impaired Sonic Hedgehog signaling. RESULTS We demonstrate that knocking Fuz out during embryonic mouse development results in a hypoplastic hindbrain phenotype, displaying abnormal rhombomeres with reduced length and width. This phenotype is associated with persistent reduction of ventral neuroepithelial stiffness in a notochord adjacent area at the level of the rhombomere 5. The formation of cranial and paravertebral ganglia is also impaired in these embryos. CONCLUSIONS This study reveals that hypoplastic hindbrain development, identified by abnormal rhombomere morphology and persistent loss of ventral neuroepithelial stiffness, precedes exencephaly in Fuz ablated murine mutants, indicating that the gene Fuz has a critical function sustaining normal neural tube development and neuronal differentiation.
Collapse
|
6
|
Tunable Macroscopic Alignment of Self-Assembling Peptide Nanofibers. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.02.02.578651. [PMID: 38352501 PMCID: PMC10862821 DOI: 10.1101/2024.02.02.578651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Fibrous proteins that comprise the extracellular matrix (ECM) guide cellular growth and tissue organization. A lack of synthetic strategies able to generate aligned, ECM-mimetic biomaterials has hampered bottom-up tissue engineering of anisotropic tissues and led to a limited understanding of cell-matrix interactions. Here, we present a facile extrusion-based fabrication method to produce anisotropic, nanofibrous hydrogels using self-assembling peptides. The application of shear force coinciding with ion-triggered gelation is used to kinetically trap supramolecular nanofibers into aligned, hierarchical structures. We establish how modest changes in phosphate buffer concentration during peptide self-assembly can be used to tune their alignment and packing. In addition, increases in the nanostructural anisotropy of fabricated hydrogels are found to enhance their strength and stiffness under hydrated conditions. To demonstrate their utility as an ECM-mimetic biomaterial, aligned nanofibrous hydrogels are used to guide directional spreading of multiple cell types, but strikingly, increased matrix alignment is not always correlated with increased cellular alignment. Nanoscale observations reveal differences in cell-matrix interactions between variably aligned scaffolds and implicate the need for mechanical coupling for cells to understand nanofibrous alignment cues. In total, innovations in the supramolecular engineering of self-assembling peptides allow us to generate a gradient of anisotropic nanofibrous hydrogels, which are used to better understand directed cell growth.
Collapse
|
7
|
Optical coherence elastography measures the biomechanical properties of the ex vivo porcine cornea after LASIK. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:016002. [PMID: 38223300 PMCID: PMC10787573 DOI: 10.1117/1.jbo.29.1.016002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/29/2023] [Accepted: 12/26/2023] [Indexed: 01/16/2024]
Abstract
Significance The biomechanical impact of refractive surgery has long been an area of investigation. Changes to the cornea structure cause alterations to its mechanical integrity, but few studies have examined its specific mechanical impact. Aim To quantify how the biomechanical properties of the cornea are altered by laser assisted in situ keratomileusis (LASIK) using optical coherence elastography (OCE) in ex vivo porcine corneas. Approach Three OCE techniques, wave-based air-coupled ultrasound (ACUS) OCE, heartbeat (Hb) OCE, and compression OCE were used to measure the mechanical properties of paired porcine corneas, where one eye of the pair was left untreated, and the fellow eye underwent LASIK. Changes in stiffness as a function of intraocular pressure (IOP) before and after LASIK were measured using each technique. Results ACUS-OCE showed that corneal stiffness changed as a function of IOP for both the untreated and the treated groups. The elastic wave speed after LASIK was lower than before LASIK. Hb-OCE and compression OCE showed regional changes in corneal strain after LASIK, where the absolute strain difference between the cornea anterior and posterior increased after LASIK. Conclusions The results of this study suggest that LASIK may soften the cornea and that these changes are largely localized to the region where the surgery was performed.
Collapse
|
8
|
Maternal circulating miRNAs contribute to negative pregnancy outcomes by altering placental transcriptome and fetal vascular dynamics. PLoS One 2023; 18:e0290720. [PMID: 37930978 PMCID: PMC10627460 DOI: 10.1371/journal.pone.0290720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 08/11/2023] [Indexed: 11/08/2023] Open
Abstract
Circulating miRNAs the in blood are promising biomarkers for predicting pregnancy complications and adverse birth outcomes. Previous work identified 11 gestationally elevated maternal circulating miRNAs (HEamiRNAs) that predicted infant growth deficits following prenatal alcohol exposure and regulated epithelial-mesenchymal transition in the placenta. Here we show that a single intravascular administration of pooled murine-conserved HEamiRNAs to pregnant mice on gestational day 10 (GD10) attenuates umbilical cord blood flow during gestation, explaining the observed intrauterine growth restriction (IUGR), specifically decreased fetal weight, and morphometric indices of cranial growth. Moreover, RNAseq of the fetal portion of the placenta demonstrated that this single exposure has lasting transcriptomic changes, including upregulation of members of the Notch pathway (Dll4, Rfng, Hey1), which is a pathway important for trophoblast migration and differentiation. Weighted gene co-expression network analysis also identified chemokine signaling, which is responsible for regulating immune cell-mediated angiogenesis in the placenta, as an important predictor of fetal growth and head size. Our data suggest that HEamiRNAs perturb the expression of placental genes relevant for angiogenesis, resulting in impaired umbilical cord blood flow and subsequently, IUGR.
Collapse
|
9
|
Nanobomb optical coherence elastography in multilayered phantoms. BIOMEDICAL OPTICS EXPRESS 2023; 14:5670-5681. [PMID: 38021113 PMCID: PMC10659790 DOI: 10.1364/boe.502576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/23/2023] [Accepted: 10/03/2023] [Indexed: 12/01/2023]
Abstract
Many tissues are composed of layered structures, and a better understanding of the changes in the layered tissue biomechanics can enable advanced guidance and monitoring of therapy. The advent of elastography using longitudinally propagating shear waves (LSWs) has created the prospect of a high-resolution assessment of depth-dependent tissue elasticity. Laser activation of liquid-to-gas phase transition of dye-loaded perfluorocarbon (PFC) nanodroplets (a.k.a., nanobombs) can produce highly localized LSWs. This study aims to leverage the potential of photoactivation of nanobombs to incudce LSWs with very high-frequency content in wave-based optical coherence elastography (OCE) to estimate the elasticity gradient with high resolution. In this work, we used multilayered tissue-mimicking phantoms to demonstrate that highly localized nanobomb (NB)-induced LSWs can discriminate depth-wise tissue elasticity gradients. The results show that the NB-induced LSWs rapidly change speed when transitioning between layers with different mechanical properties, resulting in an elasticity resolution of ∼65 µm. These results show promise for characterizing the elasticity of multilayer tissue with a fine resolution.
Collapse
|
10
|
Multifocal acoustic radiation force-based reverberant optical coherence elastography for evaluation of ocular globe biomechanical properties. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:095001. [PMID: 37701876 PMCID: PMC10494982 DOI: 10.1117/1.jbo.28.9.095001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 08/01/2023] [Accepted: 08/28/2023] [Indexed: 09/14/2023]
Abstract
Significance Quantifying the biomechanical properties of the whole eye globe can provide a comprehensive understanding of the interactions among interconnected ocular components during dynamic physiological processes. By doing so, clinicians and researchers can gain valuable insights into the mechanisms underlying ocular diseases, such as glaucoma, and design interventions tailored to each patient's unique needs. Aim The aim of this study was to evaluate the feasibility and effectiveness of a multifocal acoustic radiation force (ARF) based reverberant optical coherence elastography (RevOCE) technique for quantifying shear wave speeds in different ocular components simultaneously. Approach We implemented a multifocal ARF technique to generate reverberant shear wave fields, which were then detected using phase-sensitive optical coherence tomography. A 3D-printed acoustic lens array was employed to manipulate a collimated ARF beam generated by an ultrasound transducer, producing multiple focused ARF beams on mouse eye globes ex vivo. RevOCE measurements were conducted using an excitation pulse train consisting of 10 cycles at 3 kHz, followed by data processing to produce a volumetric map of the shear wave speed. Results The results show that the system can successfully generate reverberant shear wave fields in the eye globe, allowing for simultaneous estimation of shear wave speeds in various ocular components, including cornea, iris, lens, sclera, and retina. A comparative analysis revealed notable differences in wave speeds between different parts of the eye, for example, between the apical region of the cornea and the pupillary zone of the iris (p = 0.003 ). Moreover, the study also revealed regional variations in the biomechanical properties of ocular components as evidenced by greater wave speeds near the apex of the cornea compared to its periphery. Conclusions The study demonstrated the effectiveness of RevOCE based on a non-invasive multifocal ARF for assessing the biomechanical properties of the whole eyeball. The findings indicate the potential to provide a comprehensive understanding of the mechanical behavior of the whole eye, which could lead to improved diagnosis and treatment of ocular diseases.
Collapse
|
11
|
Disruption of Fuz in mouse embryos generates hypoplastic hindbrain development and reduced cranial nerve ganglia. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.08.04.552068. [PMID: 37577618 PMCID: PMC10418252 DOI: 10.1101/2023.08.04.552068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
The formation of the brain and spinal cord is initiated in the earliest stages of mammalian pregnancy in a highly organized process known as neurulation. Convergent and extension movements transforms a flat sheet of ectodermal cells into a narrow and elongated line of neuroepithelia, while a major source of Sonic Hedgehog signaling from the notochord induces the overlying neuroepithelial cells to form two apposed neural folds. Afterward, neural tube closure occurs by synchronized coordination of the surface ectoderm and adjacent neuroepithelial walls at specific axial regions known as neuropores. Environmental or genetic interferences can impair neurulation resulting in neural tube defects. The Fuz gene encodes a subunit of the CPLANE complex, which is a macromolecular planar polarity effector required for ciliogenesis. Ablation of Fuz in mouse embryos results in exencephaly and spina bifida, including dysmorphic craniofacial structures due to defective cilia formation and impaired Sonic Hedgehog signaling. In this work, we demonstrate that knocking Fuz out during embryonic mouse development results in a hypoplastic hindbrain phenotype, displaying abnormal rhombomeres with reduced length and width. This phenotype is associated with persistent loss of ventral neuroepithelial stiffness, in a notochord adjacent area at the level of the rhombomere 5, preceding the development of exencephaly in Fuz ablated mutants. The formation of cranial and paravertebral ganglia is also impaired in these embryos, indicating that Fuz has a critical function sustaining normal neural tube development and neuronal differentiation. SIGNIFICANCE STATEMENT Neural tube defects (NTDs) are a common cause of disability in children, representing the second most common congenital structural malformation in humans following only congenital cardiovascular malformations. NTDs affect approximately 1 to 2 pregnancies per 1000 births every year worldwide, when the mechanical forces folding the neural plate fails to close at specific neuropores located anteriorly (cranial) or posteriorly (caudal) along the neural tube, in a process known as neurulation, which happens throughout the third and fourth weeks of human pregnancy.
Collapse
|
12
|
Assessing the effects of prenatal poly-drug exposure on fetal brain vasculature using optical coherence angiography. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:076002. [PMID: 37469831 PMCID: PMC10353480 DOI: 10.1117/1.jbo.28.7.076002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 06/28/2023] [Accepted: 07/05/2023] [Indexed: 07/21/2023]
Abstract
Significance Maternal exposure to drugs during pregnancy is known to have detrimental effects on the fetus. Alcohol (ethanol) and nicotine are two of the most commonly co-abused substances during pregnancy, and prenatal poly-drug exposure is common due, in part, to the prevalence of unplanned pregnancies. The second trimester is a critical period for fetal neurogenesis and angiogenesis. When drug exposure occurs during this time, fetal brain development is affected. Several behavioral, morphological, and functional studies have evaluated the changes in fetal brain development due to exposure to these drugs individually. However, research on the combined effects of ethanol and nicotine is far more limited, specifically on fetal vasculature changes and development. Aim We use correlation mapping optical coherence angiography (cm-OCA) to evaluate acute changes in fetal brain vasculature caused by maternal exposure to a combination of ethanol and nicotine. Approach Ethanol (16.6% v/v, at a dose of 0.75g/kg) and nicotine (at a dose of 0.1 mg/kg) were administered to pregnant mice after initial cm-OCA measurements in utero. Subsequent measurements were taken at 5-min intervals for a total period of 45 min. Results from these experiments were compared to results from our previous studies in which the mother was exposed to only ethanol (dose: 0.75 g/kg) or nicotine (dose: 0.1 mg/kg). Results While results from exposure to ethanol or nicotine independently showed vasoconstriction, no significant change in vasculature was observed with combined exposure. Conclusion Results suggested antagonistic effects of ethanol and nicotine on fetal brain vasculature.
Collapse
|
13
|
Reverberant optical coherence elastography using multifocal acoustic radiation force. OPTICS LETTERS 2023; 48:2773-2776. [PMID: 37262207 DOI: 10.1364/ol.482201] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 04/15/2023] [Indexed: 06/03/2023]
Abstract
In this study, we introduce a multifocal acoustic radiation force source that combines an ultrasound transducer and a 3D-printed acoustic lens for application in reverberant optical coherence elastography (Rev-OCE). An array of plano-concave acoustic lenses, each with an 11.8 mm aperture diameter, were used to spatially distribute the acoustic energy generated by a 1 MHz planar ultrasound transducer, producing multiple focal spots on a target plane. These focal spots generate reverberant shear wave fields detected by the optical coherence tomography (OCT) system. The effectiveness of the multifocal Rev-OCE system in probing mechanical properties with high resolution is demonstrated in layered gelatin phantoms.
Collapse
|
14
|
The lens capsule significantly affects the viscoelastic properties of the lens as quantified by optical coherence elastography. Front Bioeng Biotechnol 2023; 11:1134086. [PMID: 36970614 PMCID: PMC10034121 DOI: 10.3389/fbioe.2023.1134086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Accepted: 02/21/2023] [Indexed: 03/11/2023] Open
Abstract
The crystalline lens is a transparent, biconvex structure that has its curvature and refractive power modulated to focus light onto the retina. This intrinsic morphological adjustment of the lens to fulfill changing visual demands is achieved by the coordinated interaction between the lens and its suspension system, which includes the lens capsule. Thus, characterizing the influence of the lens capsule on the whole lens’s biomechanical properties is important for understanding the physiological process of accommodation and early diagnosis and treatment of lenticular diseases. In this study, we assessed the viscoelastic properties of the lens using phase-sensitive optical coherence elastography (PhS-OCE) coupled with acoustic radiation force (ARF) excitation. The elastic wave propagation induced by ARF excitation, which was focused on the surface of the lens, was tracked with phase-sensitive optical coherence tomography. Experiments were conducted on eight freshly excised porcine lenses before and after the capsular bag was dissected away. Results showed that the group velocity of the surface elastic wave, V, in the lens with the capsule intact (V=2.55±0.23 m/s) was significantly higher (p < 0.001) than after the capsule was removed (V=1.19±0.25 m/s). Similarly, the viscoelastic assessment using a model that utilizes the dispersion of a surface wave showed that both Young’s modulus, E, and shear viscosity coefficient, η, of the encapsulated lens (E=8.14±1.10 kPa,η=0.89±0.093 Pa∙s) were significantly higher than that of the decapsulated lens (E=3.10±0.43 kPa,η=0.28±0.021 Pa∙s). These findings, together with the geometrical change upon removal of the capsule, indicate that the capsule plays a critical role in determining the viscoelastic properties of the crystalline lens.
Collapse
|
15
|
Alcohol & cannabinoid co-use: Implications for impaired fetal brain development following gestational exposure. Exp Neurol 2023; 361:114318. [PMID: 36627039 PMCID: PMC9892278 DOI: 10.1016/j.expneurol.2023.114318] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/31/2022] [Accepted: 01/06/2023] [Indexed: 01/09/2023]
Abstract
Alcohol and marijuana are two of the most consumed psychoactive substances by pregnant people, and independently, both substances have been associated with lifelong impacts on fetal neurodevelopment. Importantly, individuals of child-bearing age are increasingly engaging in simultaneous alcohol and cannabinoid (SAC) use, which amplifies each drug's pharmacodynamic effects and increases craving for both substances. However, to date, investigations of prenatal polysubstance use are notably limited in both human and non-human populations. In this review paper, we will address what is currently known about combined exposure to these substances, both directly and prenatally, and identify shared prenatal targets from single-exposure paradigms that may highlight susceptible neurobiological mechanisms for future investigation and therapeutic intervention. Finally, we conclude this manuscript by discussing factors that we feel are essential in the consideration and experimental design of future preclinical SAC studies.
Collapse
|
16
|
Abstract
Purpose Hyaluronan (HA) is a major constituent of the extracellular matrix (ECM) that has high viscosity and is essential for maintaining tissue hydration. In the cornea, HA is enriched in the limbal region and is a key component of the limbal epithelial stem cell niche. HA is upregulated after injury participating in the formation of the provisional matrix, and has a key role in regulating the wound healing process. This study investigated whether changes in the distribution of HA before and after injury affects the biomechanical properties of the cornea in vivo. Methods Corneas of wild-type (wt) mice and mice lacking enzymes involved in the biosynthesis of HA were analyzed before, immediately after, and 7 and 14 days after a corneal alkali burn (AB). The corneas were evaluated using both a ring light and fluorescein stain by in vivo confocal microscopy, optical coherence elastography (OCE), and immunostaining of corneal whole mounts. Results Our results show that wt mice and mice lacking HA synthase (Has)1 and 3 present an increase in corneal stiffness 7 and 14 days after AB without a significant increase in HA expression and absence of scarring at 14 days after AB. In contrast, mice lacking Has2 present a significant decrease in corneal stiffness, with a significant increase in HA expression and scarring at 14 days after AB. Conclusions Our findings show that the mechanical properties of the cornea are significantly modulated by changes in HA distribution following alkali burn.
Collapse
|
17
|
Multiple Optical Elastography Techniques Reveal the Regulation of Corneal Stiffness by Collagen XII. Invest Ophthalmol Vis Sci 2022; 63:24. [DOI: 10.1167/iovs.63.12.24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
18
|
Correction: NADPH oxidase mediates microtubule alterations and diaphragm dysfunction in dystrophic mice. eLife 2022; 11:84169. [PMID: 36250696 PMCID: PMC9576267 DOI: 10.7554/elife.84169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
19
|
Longitudinal assessment of the effect of alkali burns on corneal biomechanical properties using optical coherence elastography. JOURNAL OF BIOPHOTONICS 2022; 15:e202200022. [PMID: 35460537 PMCID: PMC11057918 DOI: 10.1002/jbio.202200022] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 03/29/2022] [Accepted: 04/22/2022] [Indexed: 06/14/2023]
Abstract
Eye injury due to alkali burn is a severe ocular trauma that can profoundly affect corneal structure and function, including its biomechanical properties. Here, we assess the changes in the mechanical behavior of mouse corneas in response to alkali-induced injury by conducting longitudinal measurements using optical coherence elastography (OCE). A non-contact air-coupled ultrasound transducer was used to induce elastic waves in control and alkali-injured mouse corneas in vivo, which were imaged with phase-sensitive optical coherence tomography. Corneal mechanical properties were estimated using a modified Rayleigh-Lamb wave model, and results show that Young's modulus of alkali-burned corneas were significantly greater than that of their healthy counterparts on days 7 (p = 0.029) and 14 (p = 0.026) after injury. These findings, together with the changes in the shear viscosity coefficient postburn, indicate that the mechanical properties of the alkali-burned cornea are significantly modulated during the wound healing process.
Collapse
|
20
|
Prenatal alcohol exposure contributes to negative pregnancy outcomes by altering fetal vascular dynamics and the placental transcriptome. Alcohol Clin Exp Res 2022; 46:1036-1049. [PMID: 35474222 PMCID: PMC9325399 DOI: 10.1111/acer.14846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/17/2022] [Accepted: 04/18/2022] [Indexed: 11/28/2022]
Abstract
Background Prenatal alcohol exposure (PAE) has been shown to alter fetal blood flow in utero and is also associated with placental insufficiency and intrauterine growth restriction (IUGR), suggesting an underlying connection between perturbed circulation and pregnancy outcomes. Methods Timed‐pregnant C57/BL6NHsd mice, bred in‐house, were exposed by gavage on gestational day 10 (GD10) to ethanol (3 g/kg) or purified water, as a control. Pulse‐wave Doppler ultrasound measurements for umbilical arteries and ascending aorta were obtained post‐gavage (GD12, GD14, GD18) on 2 fetuses/litter. RNA from the non‐decidual (labyrinthine and junctional zone) portion of placentas was isolated and processed for RNA‐seq and subsequent bioinformatic analyses, and the association between transcriptomic changes and fetal phenotypes assessed. Results Exposure to ethanol in pregnant mice on GD10 attenuates umbilical cord blood flow transiently during gestation, and is associated with indices of IUGR, specifically decreased fetal weight and morphometric indices of cranial growth. Moreover, RNA‐seq of the fetal portion of the placenta demonstrated that this single exposure has lasting transcriptomic changes, including upregulation of Tet3, which is associated with spontaneous abortion. Weighted gene co‐expression network analysis (WGCNA) identified erythrocyte differentiation and homeostasis as important pathways associated with improved umbilical cord blood flow as gestation progresses. WGCNA also identified sensory perception of chemical stimulus/odorant and receptor activity as important pathways associated with cranial growth. Conclusion Our data suggest that PAE perturbs the expression of placental genes relevant for placental hematopoiesis and environmental sensing, resulting in transient impairment of umbilical cord blood flow and, subsequently, IUGR.
Collapse
|
21
|
Micron-scale hysteresis measurement using dynamic optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2022; 13:3021-3041. [PMID: 35774312 PMCID: PMC9203113 DOI: 10.1364/boe.457617] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 04/11/2022] [Accepted: 04/14/2022] [Indexed: 05/28/2023]
Abstract
We present a novel optical coherence elastography (OCE) method to characterize mechanical hysteresis of soft tissues based on transient (milliseconds), low-pressure (<20 Pa) non-contact microliter air-pulse stimulation and micrometer-scale sample displacements. The energy dissipation rate (sample hysteresis) was quantified for soft-tissue phantoms (0.8% to 2.0% agar) and beef shank samples under different loading forces and displacement amplitudes. Sample hysteresis was defined as the loss ratio (hysteresis loop area divided by the total loading energy). The loss ratio was primarily driven by the sample unloading response which decreased as loading energy increased. Samples were distinguishable based on their loss ratio responses as a function loading energy or displacement amplitude. Finite element analysis and mechanical testing methods were used to validate these observations. We further performed the OCE measurements on a beef shank tissue sample to distinguish the muscle and connective tissue components based on the displacement and hysteresis features. This novel, noninvasive OCE approach has the potential to differentiate soft tissues by quantifying their viscoelasticity using micron-scale transient tissue displacement dynamics. Focal tissue hysteresis measurements could provide additional clinically useful metrics for guiding disease diagnosis and tissue treatment responses.
Collapse
|
22
|
In vivo assessment of corneal biomechanics under a localized cross-linking treatment using confocal air-coupled optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2022; 13:2644-2654. [PMID: 35774330 PMCID: PMC9203097 DOI: 10.1364/boe.456186] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/19/2022] [Accepted: 03/20/2022] [Indexed: 05/25/2023]
Abstract
The localized application of the riboflavin/UV-A collagen cross-linking (UV-CXL) corneal treatment has been proposed to concentrate the stiffening process only in the compromised regions of the cornea by limiting the epithelium removal and irradiation area. However, current clinical screening devices dedicated to measuring corneal biomechanics cannot provide maps nor spatial-dependent changes of elasticity in corneas when treated locally with UV-CXL. In this study, we leverage our previously reported confocal air-coupled ultrasonic optical coherence elastography (ACUS-OCE) probe to study local changes of corneal elasticity in three cases: untreated, half-CXL-treated, and full-CXL-treated in vivo rabbit corneas (n = 8). We found a significant increase of the shear modulus in the half-treated (>450%) and full-treated (>650%) corneal regions when compared to the non-treated cases. Therefore, the ACUS-OCE technology possesses a great potential in detecting spatially-dependent mechanical properties of the cornea at multiple meridians and generating elastography maps that are clinically relevant for patient-specific treatment planning and monitoring of UV-CXL procedures.
Collapse
|
23
|
Multimodal Heartbeat and Compression Optical Coherence Elastography for Mapping Corneal Biomechanics. Front Med (Lausanne) 2022; 9:833597. [PMID: 35479957 PMCID: PMC9037093 DOI: 10.3389/fmed.2022.833597] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 02/28/2022] [Indexed: 11/13/2022] Open
Abstract
The biomechanical properties of the cornea have a profound influence on the health, structural integrity, and function of the eye. Understanding these properties may be critical for diagnosis and identifying disease pathogenesis. This work demonstrates how two different elastography techniques can be combined for a multimodal approach to measuring corneal biomechanical properties. Heartbeat optical coherence elastography (Hb-OCE) and compression OCE were performed simultaneously to measure the stiffness of the cornea in an in vivo rabbit model. Measurements were further performed after collagen crosslinking to demonstrate how the combined technique can be used to measure changes in corneal stiffness and map mechanical contrast. The results of this work further suggest that measurements from Hb-OCE and compression OCE are comparable, meaning that Hb-OCE and compression OCE may be used interchangeably despite distinct differences in both techniques.
Collapse
|
24
|
Multimodal imaging system combining optical coherence tomography and Brillouin microscopy for neural tube imaging. OPTICS LETTERS 2022; 47:1347-1350. [PMID: 35290310 PMCID: PMC9088521 DOI: 10.1364/ol.453996] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 02/03/2022] [Indexed: 06/14/2023]
Abstract
To understand the dynamics of tissue stiffness during neural tube formation and closure in a murine model, we have developed a multimodal, coaligned imaging system combining optical coherence tomography (OCT) and Brillouin microscopy. Brillouin microscopy can map the longitudinal modulus of tissue but cannot provide structural images. Thus, it is limited for imaging dynamic processes such as neural tube formation and closure. To overcome this limitation, we have combined Brillouin microscopy and OCT in one coaligned instrument. OCT provided depth-resolved structural imaging with a micrometer-scale spatial resolution to guide stiffness mapping by Brillouin modality. 2D structural and Brillouin frequency shift maps were acquired of mouse embryos at gestational day (GD) 8.5, 9.5, and 10.5 with the multimodal system. The results demonstrate the capability of the system to obtain structural and stiffness information simultaneously.
Collapse
|
25
|
Introduction to optical coherence elastography: tutorial. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:418-430. [PMID: 35297425 PMCID: PMC10052825 DOI: 10.1364/josaa.444808] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 01/25/2022] [Indexed: 06/03/2023]
Abstract
Optical coherence elastography (OCE) has seen rapid growth since its introduction in 1998. The past few decades have seen tremendous advancements in the development of OCE technology and a wide range of applications, including the first clinical applications. This tutorial introduces the basics of solid mechanics, which form the foundation of all elastography methods. We then describe how OCE measurements of tissue motion can be used to quantify tissue biomechanical parameters. We also detail various types of excitation methods, imaging systems, acquisition schemes, and data processing algorithms and how various parameters associated with each step of OCE imaging can affect the final quantitation of biomechanical properties. Finally, we discuss the future of OCE, its potential, and the next steps required for OCE to become an established medical imaging technology.
Collapse
|
26
|
Wave-based optical coherence elastography: The 10-year perspective. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2022; 4:012007. [PMID: 35187403 PMCID: PMC8856668 DOI: 10.1088/2516-1091/ac4512] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
After 10 years of progress and innovation, optical coherence elastography (OCE) based on the propagation of mechanical waves has become one of the major and the most studied OCE branches, producing a fundamental impact in the quantitative and nondestructive biomechanical characterization of tissues. Preceding previous progress made in ultrasound and magnetic resonance elastography; wave-based OCE has pushed to the limit the advance of three major pillars: (1) implementation of novel wave excitation methods in tissues, (2) understanding new types of mechanical waves in complex boundary conditions by proposing advance analytical and numerical models, and (3) the development of novel estimators capable of retrieving quantitative 2D/3D biomechanical information of tissues. This remarkable progress promoted a major advance in answering basic science questions and the improvement of medical disease diagnosis and treatment monitoring in several types of tissues leading, ultimately, to the first attempts of clinical trials and translational research aiming to have wave-based OCE working in clinical environments. This paper summarizes the fundamental up-to-date principles and categories of wave-based OCE, revises the timeline and the state-of-the-art techniques and applications lying in those categories, and concludes with a discussion on the current challenges and future directions, including clinical translation research.
Collapse
|
27
|
Ultra-fast dynamic line-field optical coherence elastography. OPTICS LETTERS 2021; 46:4742-4744. [PMID: 34598188 PMCID: PMC9121022 DOI: 10.1364/ol.435278] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 08/20/2021] [Indexed: 05/12/2023]
Abstract
In this work, we present an ultra-fast line-field optical coherence elastography system (LF-OCE) with an 11.5 MHz equivalent A-line rate. The system was composed of a line-field spectral domain optical coherence tomography system based on a supercontinuum light source, Michelson-type interferometer, and a high-speed 2D spectrometer. The system performed ultra-fast imaging of elastic waves in tissue-mimicking phantoms of various elasticities. The results corroborated well with mechanical testing. Following validation, LF-OCE measurements were made in in situ and in in vivo rabbit corneas under various conditions. The results show the capability of the system to rapidly image elastic waves in tissues.
Collapse
|
28
|
Accuracy of Common Motion Estimators in Wave-Based Optical Coherence Elastography. JOURNAL OF BIOMEDICAL PHOTONICS & ENGINEERING 2021. [DOI: 10.18287/jbpe21.07.040303] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
29
|
Multimodal high-resolution embryonic imaging with light sheet fluorescence microscopy and optical coherence tomography. OPTICS LETTERS 2021; 46:4180-4183. [PMID: 34469969 PMCID: PMC8903154 DOI: 10.1364/ol.430202] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 07/16/2021] [Indexed: 06/13/2023]
Abstract
A high-resolution imaging system combining optical coherence tomography (OCT) and light sheet fluorescence microscopy (LSFM) was developed. LSFM confined the excitation to only the focal plane, removing the out of plane fluorescence. This enabled imaging a murine embryo with higher speed and specificity than traditional fluorescence microscopy. OCT gives information about the structure of the embryo from the same plane illuminated by LSFM. The co-planar OCT and LSFM instrument was capable of performing co-registered functional and structural imaging of mouse embryos simultaneously.
Collapse
|
30
|
Neural network-based image reconstruction in swept-source optical coherence tomography using undersampled spectral data. LIGHT, SCIENCE & APPLICATIONS 2021; 10:155. [PMID: 34326306 PMCID: PMC8322159 DOI: 10.1038/s41377-021-00594-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 07/02/2021] [Accepted: 07/06/2021] [Indexed: 05/13/2023]
Abstract
Optical coherence tomography (OCT) is a widely used non-invasive biomedical imaging modality that can rapidly provide volumetric images of samples. Here, we present a deep learning-based image reconstruction framework that can generate swept-source OCT (SS-OCT) images using undersampled spectral data, without any spatial aliasing artifacts. This neural network-based image reconstruction does not require any hardware changes to the optical setup and can be easily integrated with existing swept-source or spectral-domain OCT systems to reduce the amount of raw spectral data to be acquired. To show the efficacy of this framework, we trained and blindly tested a deep neural network using mouse embryo samples imaged by an SS-OCT system. Using 2-fold undersampled spectral data (i.e., 640 spectral points per A-line), the trained neural network can blindly reconstruct 512 A-lines in 0.59 ms using multiple graphics-processing units (GPUs), removing spatial aliasing artifacts due to spectral undersampling, also presenting a very good match to the images of the same samples, reconstructed using the full spectral OCT data (i.e., 1280 spectral points per A-line). We also successfully demonstrate that this framework can be further extended to process 3× undersampled spectral data per A-line, with some performance degradation in the reconstructed image quality compared to 2× spectral undersampling. Furthermore, an A-line-optimized undersampling method is presented by jointly optimizing the spectral sampling locations and the corresponding image reconstruction network, which improved the overall imaging performance using less spectral data points per A-line compared to 2× or 3× spectral undersampling results. This deep learning-enabled image reconstruction approach can be broadly used in various forms of spectral-domain OCT systems, helping to increase their imaging speed without sacrificing image resolution and signal-to-noise ratio.
Collapse
|
31
|
Micro Air-Pulse Spatial Deformation Spreading Characterizes Degree of Anisotropy in Tissues. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2021; 27:6800810. [PMID: 33994766 PMCID: PMC8117953 DOI: 10.1109/jstqe.2020.3038633] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In optical coherence elastography (OCE), air-pulse stimulation has been widely used to produce propagation of mechanical waves for elastic characterization of tissues. In this paper, we propose the use of spatial deformation spreading (SDS) on the surface of samples produced by air-pulse stimulation for the OCE of transverse isotropic tissues. Experiments in isotropic tissue-mimicking phantoms and anisotropic chicken tibialis muscle were conducted using a spectral-domain optical coherence tomography system synchronized with a confocal air-pulse stimulation. SDS measurements were compared with wave speeds values calculated at different propagation angles. We found an approximately linear relationship between shear wave speed and SDS in isotropic phantoms, which was confirmed with predictions made by the numerical integration of a wave propagation model. Experimental measurements in chicken muscle show a good agreement between SDS and surface wave speed taken along and across the axis of symmetry of the tissues, also called degree of anisotropy. In summary, these results demonstrated the capabilities of SDS produced by the air-pulse technique in measuring the shear elastic anisotropy of transverse isotropic tissues.
Collapse
|
32
|
Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2021; 2:179-186. [PMID: 34179823 PMCID: PMC8224461 DOI: 10.1109/ojemb.2021.3075569] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Objective: We compare the repeatability and accuracy of ultrasound shear wave elastography (USE) and transient optical coherence elastography (OCE). Methods: Elastic wave speed in gelatin phantoms and chicken breast was measured with USE and OCE and compared with uniaxial mechanical compression testing. Intra- and Inter-repeatability were analyzed using Bland-Altman plots and intraclass correlation coefficients (ICC). Results: OCE and USE differed from uniaxial testing by a mean absolute percent error of 8.92% and 16.9%, respectively, across eight phantoms of varying stiffness. Upper and lower limits of agreement for intrasample repeatability for USE and OCE were ±0.075 m/s and −0.14 m/s and 0.13 m/s, respectively. OCE and USE both had ICCs of 0.9991. In chicken breast, ICC for USE was 0.9385 and for OCE was 0.9924. Conclusion: OCE and USE can detect small speed changes and give comparable measurements. These measurements correspond well with uniaxial testing.
Collapse
|
33
|
In vivo human corneal natural frequency quantification using dynamic optical coherence elastography: Repeatability and reproducibility. J Biomech 2021; 121:110427. [PMID: 33873114 DOI: 10.1016/j.jbiomech.2021.110427] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 03/20/2021] [Accepted: 03/29/2021] [Indexed: 12/14/2022]
Abstract
Reliable and quantitative assessment of corneal biomechanics is important for the detection and treatment of corneal disease. The present study evaluates the repeatability and reproducibility of a novel optical coherence tomography (OCT)-based elastography (OCE) method for in vivo quantification of corneal natural frequency in 20 normal human eyes. Sub-micron corneal oscillations were induced by repeated low-force (13 Pa) microliter air pulses at the corneal apex and were observed by common-path phase-sensitive OCT imaging adjacent to a measurement region of 1-6.25 mm2. Corneal natural frequencies were quantified using a single degree of freedom model based on the corneal oscillations. Corneal natural frequencies ranged from 234 to 277 Hz (coefficient of variation: 3.2%; n = 286 for a 2.5 × 2.5 mm2 area; time: 28.6 s). The same natural frequencies can be acquired using a smaller sampling size (n = 9 for 1 mm2) and a shorter time (0.9 s). Spatial distribution and local changes in natural frequencies can be distinguished using denser sampling (e.g., 26 × 41 points for 2.5 × 5 mm2). This novel optical method demonstrates highly repeatable and reliable in vivo measurements of human corneal natural frequencies. While further studies are required to fully characterize anatomical and structural dependencies, this method may be complementary to the current OCE methods used to estimate Young's modulus from strain- or shear-wave-based measurements for the quantitative determination of corneal biomechanics.
Collapse
|
34
|
Abstract
Assessing the biomechanical properties of the cornea is crucial for detecting the onset and progression of eye diseases. In this work, we demonstrate the application of compression-based optical coherence elastography (OCE) to measure the biomechanical properties of the cornea under various conditions, including validation in an in situ rabbit model and a demonstration of feasibility for in vivo measurements. Our results show a stark increase in the stiffness of the corneas as IOP was increased. Moreover, UV-A/riboflavin corneal collagen crosslinking (CXL) also dramatically increased the stiffness of the corneas. The results were consistent across 4 different scenarios (whole CXL in situ, partial CXL in situ, whole CXL in vivo, and partial CXL in vivo), emphasizing the reliability of compression OCE to measure corneal biomechanical properties and its potential for clinical applications.
Collapse
|
35
|
Heartbeat optical coherence elastography: corneal biomechanics in vivo. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200338LR. [PMID: 33624461 PMCID: PMC7901857 DOI: 10.1117/1.jbo.26.2.020502] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 01/19/2021] [Indexed: 05/02/2023]
Abstract
SIGNIFICANCE Mechanical assessment of the cornea can provide important structural and functional information regarding its health. Current clinically available tools are limited in their efficacy at measuring corneal mechanical properties. Elastography allows for the direct estimation of mechanical properties of tissues in vivo but is generally performed using external excitation force. AIM To show that heartbeat optical coherence elastography (Hb-OCE) can be used to assess the mechanical properties of the cornea in vivo. APPROACH Hb-OCE was utilized to detect Hb-induced deformations in the rabbit cornea in vivo without the need for external excitation. Furthermore, we demonstrate how this technique can distinguish corneal stiffness between untreated (UT) and crosslinked (CXL) tissue. RESULTS Our results demonstrate that stiffness changes in the cornea can be detected using only the Hb-induced deformations in the cornea. Additionally, we demonstrate a statistically significant difference in strain between the UT and CXL corneas. CONCLUSIONS Hb-OCE may be an effective tool for assessing the mechanical properties of the cornea in vivo without the need for external excitation. This tool may be effective for clinical assessment of corneal mechanical properties because it only requires optical coherence tomography imaging and data processing.
Collapse
|
36
|
Abstract
SIGNIFICANCE A novel imaging technology, dynamic optical coherence elastography (OCE), was adapted for clinical noninvasive measurements of corneal biomechanics. PURPOSE Determining corneal biomechanical properties is a long-standing challenge. Elasticity imaging methods have recently been developed and applied for clinical evaluation of soft tissues in cancer detection, atherosclerotic plaque evaluation, surgical guidance, and more. Here, we describe the use of dynamic OCE to characterize mechanical wave propagation in the human cornea in vivo, thus providing a method for clinical determination of corneal biomechanical properties. METHODS High-resolution phase-sensitive optical coherence tomography imaging was combined with microliter air-pulse tissue stimulation to perform dynamic elasticity measurements in 18 eyes of nine participants. Low-pressure (0.1 mmHg), spatiotemporally discreet (150 μm, 800 μs) tissue stimulation produced submicron-scale tissue deformations that were measured at multiple positions over a 1-mm2 area. Surface wave velocity was measured and used to determine tissue stiffness. Elastic wave propagation velocity was measured and evaluated as a function of IOP and central corneal thickness. RESULTS Submicron corneal surface displacement amplitude (range, 0.005 to 0.5 μm) responses were measured with high sensitivity (0.24 nm). Corneal elastic wave velocity ranged from 2.4 to 4.2 m/s (mean, 3.5; 95% confidence interval, 3.2 to 3.8 m/s) and was correlated with central corneal thickness (r = 0.64, P < .001) and IOP (r = 0.52, P = .02). CONCLUSIONS Phase-sensitive optical coherence tomography imaging combined with microliter air-pulse mechanical tissue stimulation has sufficient detection sensitivity to observe submicron elastic wave propagation in corneal tissue. These measurements enable in vivo corneal stiffness determinations that will be further studied for use with disease detection and for monitoring clinical interventions.
Collapse
|
37
|
Confocal air-coupled ultrasonic optical coherence elastography probe for quantitative biomechanics. OPTICS LETTERS 2020; 45:6567-6570. [PMID: 33258863 PMCID: PMC10041740 DOI: 10.1364/ol.410593] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We present an air-coupled ultrasonic radiation force probe co-focused with a phase-sensitive optical coherence tomography (OCT) system for quantitative wave-based elastography. A custom-made 1 MHz spherically focused piezoelectric transducer with a concentric 10 mm wide circular opening allowed for confocal micro-excitation of waves and phase-sensitive OCT imaging. Phantom studies demonstrated the capabilities of this probe to produce quasi-harmonic excitation up to 4 kHz for generation of elastic waves. Experimental results in ocular tissues showed highly detailed 2D and 3D elasticity mapping using this approach with great potential for clinical translation.
Collapse
|
38
|
Dynamic Optical Coherence Elastography of the Anterior Eye: Understanding the Biomechanics of the Limbus. Invest Ophthalmol Vis Sci 2020; 61:7. [PMID: 33141893 PMCID: PMC7645208 DOI: 10.1167/iovs.61.13.7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Purpose Currently, the biomechanical properties of the corneo-scleral limbus when the eye-globe deforms are largely unknown. The purpose of this study is to evaluate changes in elasticity of the cornea, sclera, and limbus when subjected to different intraocular pressures (IOP) using wave-based optical coherence elastography (OCE). Special attention was given to the elasticity changes of the limbal region with respect to the elasticity variations in the neighboring corneal and scleral regions. Methods Continuous harmonic elastic waves (800 Hz) were mechanically induced in the sclera near the corneo-sclera limbus of in situ porcine eye-globes (n = 8). Wave propagation was imaged using a phase-sensitive optical coherence tomography system (PhS-OCT). The eyes were subjected to five different IOP-levels (10, 15, 20, 30, and 40 mm Hg), and spatially distributed propagation velocities were calculated along corneal, limbal, and scleral regions. Finite element analysis (FEA) of the same regions under the same excitation conditions were conducted for further validation of results. Results FEA demonstrated that the stiffness of the heterogeneous cornea-limbus-sclera transition can be characterized by phase velocity measurements of the elastic waves produced at 800 Hz in the anterior eye. Experimental results revealed that the wave speed in the limbus (cL = 6.5 m/s) is between the cornea (cc = 2.9 m/s) and sclera (cs = 10.0 m/s) at a physiological IOP level (15 mm Hg) and rapidly increases as the IOP level is increased, even surpassing the wave speed in the sclera. Finally, the change in elastic wave speed in the limbus (ΔcL∼18.5 m/s) was greater than in the cornea (Δcc ∼12.6 m/s) and sclera (Δcs∼8.1 m/s) for the same change in IOP. Conclusions We demonstrated that wave-based OCE can be utilized to assess limbus biomechanical properties. Moreover, experimental evidence showed that the corneo-scleral limbus is highly nonlinear compared to the cornea and sclera when the eye-globe is deformed by an increase of IOP. This may suggest that the limbus has enough structural flexibility to stabilize anterior eye shape during IOP changes.
Collapse
|
39
|
Repetitive optical coherence elastography measurements with blinking nanobombs. BIOMEDICAL OPTICS EXPRESS 2020; 11:6659-6673. [PMID: 33282515 PMCID: PMC7687956 DOI: 10.1364/boe.401734] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 09/19/2020] [Accepted: 10/06/2020] [Indexed: 05/04/2023]
Abstract
Excitation of dye-loaded perfluorocarbon nanoparticles (nanobombs) can generate highly localized axially propagating longitudinal shear waves (LSW) that can be used to quantify tissue mechanical properties without transversal scanning of the imaging beam. In this study, we used repetitive excitations of dodecafluoropentane (C5) and tetradecafluorohexane (C6) nanobombs by a nanosecond-pulsed laser to produce multiple LSWs from a single spot in a phantom. A 1.5 MHz Fourier-domain mode-locked laser in combination with a phase correction algorithm was used to perform elastography. Multiple nanobomb activations were also monitored by detecting photoacoustic signals. Our results demonstrate that C6 nanobombs can be used for repetitive generation of LSW from a single spot for the purpose of material elasticity assessment. This study opens new avenues for continuous quantification of tissue mechanical properties using single delivery of the nanoparticles.
Collapse
|
40
|
Dose-response analysis of microvasculature changes in the murine fetal brain and the maternal extremities due to prenatal ethanol exposure. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:JBO-200176RR. [PMID: 33244919 PMCID: PMC7689263 DOI: 10.1117/1.jbo.25.12.126001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Accepted: 11/06/2020] [Indexed: 05/29/2023]
Abstract
SIGNIFICANCE Prenatal exposure to ethanol causes several morphological and neurobehavioral deficits. While there are some studies on the effects of ethanol exposure on blood flow, research focusing on acute changes in the microvasculature is limited. AIM The first aim of this study was to assess the dose-dependent changes in murine fetal brain microvasculature of developing fetuses in response to maternal alcohol consumption. The second aim was to quantify changes in vasculature occurring concurrently in the mother's hindlimb and the fetus's brain after maternal exposure to alcohol. APPROACH Correlation mapping optical coherence angiography was used to evaluate the effects of prenatal exposure to different doses of ethanol (3, 1.5, and 0.75 g / kg) on murine fetal brain vasculature in utero. Additionally, simultaneous imaging of maternal peripheral vessels and the fetal brain vasculature was performed to assess changes of the vasculature occurring concurrently in response to ethanol consumption. RESULTS The fetal brain vessel diameters (VDs) decreased by ∼47 % , 30%, and 14% in response to ethanol doses of 3, 1.5, and 0.75 g / kg, respectively. However, the mother's hindlimb VD increased by 63% in response to ethanol at a dose of 3 g / kg. CONCLUSIONS Results showed a dose-dependent reduction in vascular blood flow in fetal brain vessels when the mother was exposed to ethanol, whereas vessels in the maternal hindlimb exhibited concurrent vasodilation.
Collapse
|
41
|
Characterization of retinal biomechanical properties using Brillouin microscopy. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:JBO-200208LR. [PMID: 32981240 PMCID: PMC7519206 DOI: 10.1117/1.jbo.25.9.090502] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 09/04/2020] [Indexed: 05/03/2023]
Abstract
SIGNIFICANCE The retina is critical for vision, and several diseases may alter its biomechanical properties. However, assessing the biomechanical properties of the retina nondestructively is a challenge due to its fragile nature and location within the eye globe. Advancements in Brillouin spectroscopy have provided the means for nondestructive investigations of retina biomechanical properties. AIM We assessed the biomechanical properties of mouse retinas using Brillouin microscopy noninvasively and showed the potential of Brillouin microscopy to differentiate the type and layers of retinas based on stiffness. APPROACH We used Brillouin microscopy to quantify stiffness of fresh and paraformaldehyde (PFA)-fixed retinas. As further proof-of-concept, we demonstrated a change in the stiffness of a retina with N-methyl-D-aspartate (NMDA)-induced damage, compared to an undamaged sample. RESULTS We found that the retina layers with higher cell body density had higher Brillouin modulus compared to less cell-dense layers. We have also demonstrated that PFA-fixed retina samples were stiffer compared with fresh samples. Further, NMDA-induced neurotoxicity leads to retinal ganglion cell (RGC) death and reactive gliosis, increasing the stiffness of the RGC layer. CONCLUSION Brillouin microscopy can be used to characterize the stiffness distribution of the layers of the retina and can be used to differentiate tissue at different conditions based on biomechanical properties.
Collapse
|
42
|
Optical coherence tomography angiography to evaluate murine fetal brain vasculature changes caused by prenatal exposure to nicotine. BIOMEDICAL OPTICS EXPRESS 2020; 11:3618-3632. [PMID: 33014555 PMCID: PMC7510910 DOI: 10.1364/boe.394905] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 06/01/2020] [Accepted: 06/02/2020] [Indexed: 05/03/2023]
Abstract
Maternal smoking causes several defects ranging from intrauterine growth restriction to sudden infant death syndrome and spontaneous abortion. While several studies have documented the effects of prenatal nicotine exposure in development and behavior, acute vasculature changes in the fetal brain due to prenatal nicotine exposure have not been evaluated yet. This study uses correlation mapping optical coherence angiography to evaluate changes in fetal brain vasculature flow caused by maternal exposure to nicotine during the second trimester-equivalent of gestation in a mouse model. The effects of two different doses of nicotine were evaluated. Results showed a decrease in the vasculature for both doses of nicotine, which was not seen in the case of the sham group.
Collapse
|
43
|
Longitudinal elastic wave imaging using nanobomb optical coherence elastography: erratum. OPTICS LETTERS 2020; 45:3296. [PMID: 32538966 DOI: 10.1364/ol.398141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Indexed: 06/11/2023]
Abstract
We present an erratum to correct an inadvertent error made during the calculations of the in-focus fluence of pulsed laser used to excite nanoparticles [Opt. Lett.44, 3162 (2019)OPLEDP0146-959210.1364/OL.44.003162] and to update the conclusion regarding laser safety limits achieved with this type of excitation.
Collapse
|
44
|
Characterization of natural frequencies from nanoscale tissue oscillations using dynamic optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2020; 11:3301-3318. [PMID: 32637256 PMCID: PMC7316029 DOI: 10.1364/boe.391324] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 05/01/2020] [Accepted: 05/12/2020] [Indexed: 05/09/2023]
Abstract
We demonstrate the use of OCT-based elastography for soft-tissue characterization using natural frequency oscillations. Sub-micrometer to sub-nanometer oscillations were induced in tissue phantoms and human cornea in vivo by perpendicular air-pulse stimulation and observed by common-path OCT imaging (sensitivity: 0.24 nm). Natural frequency and damping ratio were acquired in temporal and frequency domains using a single degree of freedom method. The dominant natural frequency was constant for different stimulation pressures (4-32 Pa) and measured distances (0.3-5.3 mm), and decreased as the sample thickness increased. The dominant natural frequencies of 0.75-2% agar phantoms were 127-774 Hz (mean coefficient of variation [CV]: 0.9%), and correlated with the square root of Young's moduli (16.5-117.8 kPa, mean CV: 5.8%). These preliminary studies show repeatable in vivo corneal natural frequency measurements (259 Hz, CV: 1.9%). This novel OCE approach can distinguish tissues and materials with different mechanical properties using the small-amplitude tissue oscillation features, and is suitable for characterizing delicate tissues in vivo such as the eye.
Collapse
|
45
|
Heartbeat OCE: corneal biomechanical response to simulated heartbeat pulsation measured by optical coherence elastography. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-9. [PMID: 32372574 PMCID: PMC7199791 DOI: 10.1117/1.jbo.25.5.055001] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Accepted: 04/24/2020] [Indexed: 05/04/2023]
Abstract
SIGNIFICANCE It is generally agreed that the corneal mechanical properties are strongly linked to many eye diseases and could be used to assess disease progression and response to therapies. Elastography is the most notable method of assessing corneal mechanical properties, but it generally requires some type of external excitation to induce a measurable displacement in the tissue. AIM We present Heartbeat Optical Coherence Elastography (Hb-OCE), a truly passive method that can measure the elasticity of the cornea based on intrinsic corneal displacements induced by the heartbeat. APPROACH Hb-OCE measurements were performed in untreated and UV-A/riboflavin cross-linked porcine corneas ex vivo, and a distinct difference in strain was detected. Furthermore, a partially cross-linked cornea was also assessed, and the treated and untreated areas were similarly distinguished. RESULTS Our results suggest that Hb-OCE can spatially map displacements in the cornea induced by small fluctuations in intraocular pressure, similar to what is induced by the heartbeat. CONCLUSIONS The described technique opens the possibility for completely passive and noncontact in vivo assessment of corneal stiffness.
Collapse
|
46
|
Clinical Corneal Optical Coherence Elastography Measurement Precision: Effect of Heartbeat and Respiration. Transl Vis Sci Technol 2020; 9:3. [PMID: 32821475 PMCID: PMC7401940 DOI: 10.1167/tvst.9.5.3] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 11/30/2019] [Indexed: 01/29/2023] Open
Abstract
Purpose Normal physiological movements (e.g., respiration and heartbeat) induce eye motions during clinical measurements of human corneal biomechanical properties using optical coherence elastography (OCE). We quantified the effects of respiratory and cardiac-induced eye motions on clinical corneal OCE measurement precision and repeatability. Methods Corneal OCE was performed using low-force, micro-air-pulse tissue stimulation and high-resolution phase-sensitive optical coherence tomography (OCT) imaging. Axial surface displacements of the corneal apex were measured (M-mode) at a 70-kHz sampling rate and three different stimulation pressures (20-60 Pa). Simultaneously, the axial corneal position was tracked with structural OCT imaging, while the heartrate and respiration were monitored over a 90 second period. Results Respiratory- and cardiac-induced eye motions have distinctly lower frequency (0.1-1 Hz) and much greater amplitude (up to ± 50 µm movements) than air-pulse-induced corneal tissue deformations (∼250 Hz, <1 µm). The corneal displacements induced during OCE measurements in vivo were -0.41 ± 0.06 µm (n = 22 measurements, coefficient of variation [CV]: 14.6%) and -0.44 ± 0.07 µm (n = 50 measurements, CV: 15.9%), respectively, from two human subjects at 40 Pa stimulation pressure. Observed variation in corneal tissue displacements were not associated with tissue stimulation magnitude, or the amplitude of physiologically induced axial eye motion. Conclusions The microsecond timescale and submicron tissue displacements observed during corneal OCE measurements are separable from normal involuntary physiological movements, such as the oculocardiac pulse and respiratory movements. Translational Relevance This work advances innovations in biomedical imaging and engineering for clinical diagnostic applications for soft-tissue biomechanical testing.
Collapse
|
47
|
Label-free optical imaging in developmental biology [Invited]. BIOMEDICAL OPTICS EXPRESS 2020; 11:2017-2040. [PMID: 32341864 PMCID: PMC7173889 DOI: 10.1364/boe.381359] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 01/30/2020] [Accepted: 02/25/2020] [Indexed: 05/03/2023]
Abstract
Application of optical imaging in developmental biology marks an exciting frontier in biomedical optics. Optical resolution and imaging depth allow for investigation of growing embryos at subcellular, cellular, and whole organism levels, while the complexity and variety of embryonic processes set multiple challenges stimulating the development of various live dynamic embryonic imaging approaches. Among other optical methods, label-free optical techniques attract an increasing interest as they allow investigation of developmental mechanisms without application of exogenous markers or fluorescent reporters. There has been a boost in development of label-free optical imaging techniques for studying embryonic development in animal models over the last decade, which revealed new information about early development and created new areas for investigation. Here, we review the recent progress in label-free optical embryonic imaging, discuss specific applications, and comment on future developments at the interface of photonics, engineering, and developmental biology.
Collapse
|
48
|
Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:2041-2051. [PMID: 32341865 PMCID: PMC7173892 DOI: 10.1364/boe.387361] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 02/27/2020] [Accepted: 03/05/2020] [Indexed: 05/03/2023]
Abstract
Assessing the biomechanical properties of the crystalline lens can provide crucial information for diagnosing disease and guiding precision therapeutic interventions. Existing noninvasive methods have been limited to global measurements. Here, we demonstrate the quantitative assessment of the elasticity of crystalline lens with a multimodal optical elastography technique, which combines dynamic wave-based optical coherence elastography (OCE) and Brillouin microscopy to overcome the drawbacks of individual modalities. OCE can provide direct measurements of tissue elasticity rapidly and quantitatively, but it is a challenge to image transparent samples such as the lens because this technique relies on backscattered light. On the other hand, Brillouin microscopy can map the longitudinal modulus with micro-scale resolution in transparent samples. However, the relationship between Brillouin-deduced modulus and Young's modulus is not straightforward and sample dependent. By combining these two techniques, we can calibrate Brillouin measurements with OCE, based on the same sample, allowing us to completely map the Young's modulus of the crystalline lens. The combined system was first validated with tissue-mimicking gelatin phantoms of varying elasticities (N = 9). The OCE data was used to calibrate the Brillouin shift measurements and subsequently map the Young's modulus of the phantoms. After validation, OCE and Brillouin measurements were performed on ex-vivo porcine lenses (N = 6), and the Young's modulus of the lenses was spatially mapped. The results show a strong correlation between Young's moduli measured by OCE and longitudinal moduli measured by Brillouin microscopy. The correlation coefficient R was 0.98 for the phantoms and 0.94 for the lenses, respectively. The mean Young's modulus of the anterior and posterior lens was 1.98 ± 0.74 kPa and 2.93 ± 1.13 kPa, respectively, and the Young's modulus of the lens nucleus was 11.90 ± 2.94 kPa. The results presented in this manuscript open a new way for truly quantitative biomechanical mapping of optically transparent (or low scattering) tissues in 3D.
Collapse
|
49
|
Laser-induced elastic wave classification: thermoelastic versus ablative regimes for all-optical elastography applications. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-13. [PMID: 32189479 PMCID: PMC7080210 DOI: 10.1117/1.jbo.25.3.035004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 03/04/2020] [Indexed: 05/03/2023]
Abstract
SIGNIFICANCE Shear wave optical coherence elastography is an emerging technique for characterizing tissue biomechanics that relies on the generation of elastic waves to obtain the mechanical contrast. Various techniques, such as contact, acoustic, and pneumatic methods, have been used to induce elastic waves. However, the lack of higher-frequency components within the elastic wave restricts their use in thin samples. The methods also require moving parts and/or tubing, which therefore limits the extent to which they can be miniaturized. AIM To overcome these limitations, we propose an all-optical approach using photothermal excitation. Depending on the absorption coefficient of the sample and the laser pulse energy, elastic waves are generated either through a thermoelastic or an ablative process. Our study aimed to experimentally determine the boundary between the thermoelastic and the ablative regimes for safe all-optical elastography applications. APPROACH Tissue-mimicking graphite-doped phantoms and chicken liver samples were used to investigate the boundary between thermoelastic and ablative regimes. A pulsed laser at 532 nm was used to induce elastic waves in the samples. Laser-induced elastic waves were detected using a line field low coherence holography instrument. The shape of the elastic wave amplitude was analyzed and used to determine the transition point between thermoelastic and ablative regimes. RESULTS The transition from the thermoelastic to the ablative regime is accompanied by the nonlinear increase in surface wave amplitude as well as the transformation of the wave shape. Correlation between the absorption coefficient and the transition point energy was experimentally determined using graphite-doped phantoms and applied to biological samples ex vivo. CONCLUSIONS Our study described a methodology for determining the boundary region between thermoelastic and ablative regimes of elastic wave generation. These can be used for the development of a safe method for completely noncontact, all-optical microscale assessment of tissue biomechanics using laser-induced elastic waves.
Collapse
|
50
|
Translational optical coherence elastography for assessment of systemic sclerosis. JOURNAL OF BIOPHOTONICS 2019; 12:e201900236. [PMID: 31343837 PMCID: PMC7184265 DOI: 10.1002/jbio.201900236] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Revised: 07/21/2019] [Accepted: 07/22/2019] [Indexed: 05/26/2023]
Abstract
Systemic sclerosis (SSc-scleroderma) is an autoimmune disorder with high mortality rate that results in excessive accumulation of collagen in the skin and internal organs. Currently, the modified Rodnan Skin Score (mRSS) is the gold standard for evaluating the dermal thickening due to SSc. However, mRSS has noticeable inter- and intra-observer variabilities as quantified by the interclass correlation coefficient (ICC: 0.6-0.75). In this work, optical coherence elastography (OCE) combined with structural optical coherence tomography (OCT) image analysis was used to assess skin thickness in 12 SSc patients and healthy volunteers. Inter- (ICC: 0.62-0.99) and intra-observer (ICC > 0.90) assessment of OCT/OCE showed excellent reliability. Clinical assessments, including histologically assessed dermal thickness (DT), mRSS, and site-specific mRSS (SMRSS) were also performed for further validation. The OCE and OCT results from the forearm demonstrated the highest correlation (OCE: 0.78, OCT: 0.65) with SMRSS. Importantly, OCE and OCT had stronger correlations with the histological DT (OCT: r = .78 and OCE: r = .74) than SMRSS (r = .57), indicating the OCT/OCE could outperform semi-quantitative clinical assessments such as SMRSS. Overall, these results demonstrate that OCT/OCE could be useful for rapid, noninvasive and objective assessments of SSc onset and monitoring skin disease progression and treatment response.
Collapse
|