1
|
Determinants of first trimester combined test participation within the central region of the Netherlands. Prenat Diagn 2016; 35:486-92. [PMID: 25613681 DOI: 10.1002/pd.4564] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2014] [Revised: 01/15/2015] [Accepted: 01/18/2015] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Our objective is to study the association between potentially influential determinants and first-trimester combined test (FCT) uptake rates in the central region of the Netherlands. METHODS Data were extracted from the national prenatal screening database Peridos and the Netherlands Perinatal Registry and compared at the level of the health care provider. Univariable and multivariable linear regression analysis was used to determine the effect of determinants (maternal age, parity, socio-economic status (SES), mode of conception, ethnicity and urbanisation) on uptake. RESULTS Prenatal screening data were available for 24 657 women and overall uptake rate was 25.7%. The strongest association with FCT uptake was found for advanced maternal age (β 2.2; 95% CI [1.7, 2.8]). Grand multiparity had a significantly negative association with FCT uptake (β -4.3; 95% CI [-5.9, -2.7]). Positive associations were found for very high urbanisation (β 0.3; 95% CI [0.1, 0.4]) and high SES (β 0.2; 95% CI [0.0, 0.3]). CONCLUSION Advanced maternal age is strongly associated with participation in prenatal testing. The role of age related risk perception should be incorporated in future policy making to support women in informed and autonomous decision making. The negative association of grand multiparity and FCT might be religion based but requires further research. © 2015 John Wiley & Sons, Ltd.
Collapse
|
2
|
Modeling Down syndrome screening performance using first-trimester serum markers. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 38:134-139. [PMID: 21800388 DOI: 10.1002/uog.8881] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVE To evaluate the modeled predictive value of three current screening markers (pregnancy-associated plasma protein-A (PAPP-A), free β-human chorionic gonadotropin (free β-hCG), and nuchal translucency (NT)) and four potential screening markers (a disintegrin and metalloprotease 12 (ADAM12), total hCG, placental protein 13 (PP13), and placental growth factor (PlGF)) for Down syndrome using different screening strategies. METHODS All markers were measured in stored first-trimester serum of 151 Down syndrome cases and 847 controls. All marker levels were expressed as gestational age-specific multiples of the median (MoMs) and comparisons were made using the Mann-Whitney U-test. Detection rates (DRs) for fixed false-positive rates (FPRs) were modeled using different screening strategies. RESULTS Significantly different median MoMs for Down syndrome cases compared to controls were found for PAPP-A (0.49 vs. 1.00; P < 0.0001), free β-hCG (1.70 vs. 1.01; P < 0.0001), ADAM12 (0.89 vs. 1.00; P < 0.0001), total hCG (1.28 vs. 1.00; P < 0.0001), PlGF (0.80 vs. 1.00; P < 0.0001) and NT (1.74 vs. 1.01; P < 0.0001). The lower PP13 MoM in Down syndrome cases (0.91 vs. 1.00) was not statistically significant (P = 0.061). Adding the four new markers to the current screening strategy (i.e. first-trimester combined test) led to an increase in DR from 77% to 80% at a 5% FPR. The modeled application of a two-sample screening strategy (with some markers assessed early and others later in the first trimester) increased the DR to 89%. In a two-step contingent screening model, using an intermediate risk range of 1 in 100 to 1 in 2000 at biochemical screening (using all markers), the overall DR was 77%, but it was predicted that only 33% of women would require referral for NT measurement. CONCLUSIONS First-trimester Down syndrome screening may be improved by adding new markers to the current screening test and by applying different screening strategies. The application of a two-sample screening model resulted in the highest predicted DR, but this should be confirmed in population-based prospective studies.
Collapse
|
3
|
Trends in the utilization of invasive prenatal diagnosis in The Netherlands during 2000-2009. Prenat Diagn 2011; 31:765-72. [PMID: 21692084 DOI: 10.1002/pd.2764] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 03/22/2011] [Accepted: 03/24/2011] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To analyze trends in the number and type of invasive procedure, reasons for referral, maternal age and chromosomal abnormalities over a 10-year period and correlate the trends to changes in the national prenatal screening policy. METHODS Data from 10 706 invasive prenatal procedures yielding a full karyotype, performed between 2000 and 2009 were extracted from the cytogenetic database in the central region of The Netherlands. Trends were analyzed. RESULTS Over a 10-year period, the number of invasive procedures halved and the percentage of chromosomal abnormalities detected, increased from 5.5 to 9.4%. After 2007, however, 5.7% of karyotypes in women over 36 years were found to be abnormal, versus 18.1% in women below 36 years. In 2009, 71.5% of women over 36 are still referred for invasive prenatal diagnosis on the indication advanced maternal age. CONCLUSIONS Changes in prenatal screening policy significantly increased referral after screening and improved the efficacy of invasive prenatal diagnosis. We show the continuing effect of the different policies applied in the past to women below and above the age of 36. To further improve efficacy of invasive prenatal diagnosis, first trimester combination screening should be actively offered to women of all ages.
Collapse
|
4
|
Grade and symmetry of normal fetal cortical development: a longitudinal two- and three-dimensional ultrasound study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 36:700-708. [PMID: 20521241 DOI: 10.1002/uog.7705] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/20/2010] [Indexed: 05/29/2023]
Abstract
OBJECTIVES Recent studies have shown the capability of ultrasound to demonstrate fetal cortical development. For practical application, it would be useful to have more insight into the physiological progress of cortical folding. A longitudinal study was undertaken to grade fetal cortical development and to study physiological asymmetry by means of a simple scoring system. The reproducibility of the scoring system and the differences between two-dimensional (2D) and three-dimensional (3D) ultrasound were also examined. METHODS A cohort of 28 patients was examined by 2D and 3D ultrasound from 20 to 40 weeks of gestation. The development of selected fissures, sulci and cortical areas were graded from 0 to 5. One examination per week of gestation was randomly selected for evaluation of intraobserver and interobserver variation. RESULTS Two-hundred and fifteen ultrasound examinations were performed in 28 patients. The development of the different cortical areas is presented. The intraobserver and interobserver agreement for assessment of grade was good. Asymmetry was common between 24 and 28 weeks, especially in female fetuses. The right parieto-occipital fissure tended to be more advanced and the left calcarine and cingulate sulci tended to be more advanced. No clinically or statistically significant differences were found between 2D and 3D ultrasound. CONCLUSIONS Evaluation of cortical development by means of a simple scoring system is feasible and reproducible. Asymmetrical development of sulci, previously only described in vitro, has now also been demonstrated in vivo. 3D ultrasound was equally accurate and repeatable and no more time consuming than 2D ultrasound.
Collapse
|
5
|
Trisomy 18 and 13 screening: consequences for the Dutch Down syndrome screening programme. Prenat Diagn 2010; 30:287-9. [PMID: 20112231 DOI: 10.1002/pd.2467] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Abstract
OBJECTIVE To evaluate the potential of maternal serum A Disintegrin And Metalloprotease 12-S (ADAM12s) as an additional marker for the combined test in the Dutch first-trimester national Down syndrome (DS) screening program. METHODS Serum samples were collected between 2004 and 2007 as part of the national program. A total of 218 singleton cases of trisomy 21 (DS), 62 trisomy 18 (Edwards syndrome) and 29 trisomy 13 (Patau syndrome) were identified. All cases were matched with controls for gestation, maternal weight and maternal age. The serum concentration of ADAM12s was determined 'blind' to outcome and expressed in multiples of the gestation-specific median for controls (MoM). RESULTS The median ADAM12s was 1.00 MoM in controls and in the DS cases at 8, 9, 10, 11, 12, 13 weeks it was 0.45 (n = 3), 0.73 (22), 0.74 (53), 0.85 (37), 0.92 (71), 1.06 (32) MoM, respectively. The median for trisomy 18 was 0.85 MoM and for trisomy 13 0.63 MoM. CONCLUSION The ADAM12s MoM values were clearly reduced in early first-trimester for all trisomies. However, the screening performance for DS did not greatly improve adding ADAM12s. ADAM12s could be an additional biochemical marker for first-trimester screening for trisomies other than DS.
Collapse
|
7
|
First trimester neurosonoembryology with automated follicle tracking: Preliminary findings. J Matern Fetal Neonatal Med 2009; 22:949-51. [DOI: 10.1080/14767050902929388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
8
|
Role of prenatal ultrasound in predicting survival and mental and motor functioning in children with spina bifida. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2009; 34:253-258. [PMID: 19670337 DOI: 10.1002/uog.6423] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVE To determine which prenatal ultrasound findings can predict survival and mental and motor functioning in children with spina bifida. METHODS Prenatal ultrasound examinations of all liveborn children who were prenatally diagnosed with spina bifida between 1997 and 2002 at the University Medical Centre, Utrecht (n = 41) were retrospectively reviewed for lesion level, head circumference, ventriculomegaly, scoliosis and talipes. These measures were correlated with postnatal anatomical (as assessed by magnetic resonance imaging (MRI)) and functional lesion levels, survival and motor and mental outcome at 5 years of age. The capacity of prenatal ultrasonography to determine lesion level was also assessed in all fetuses diagnosed with spina bifida from 2006-2007 (n = 18). RESULTS Nineteen infants died before the age of 5 years. Multivariate regression analysis showed that higher lesion level and head circumference > or = the 90th percentile on prenatal ultrasound examination were independent predictors of demise (P < 0.05 and P = 0.01, respectively). None of the ultrasound features was a predictor of motor or mental functioning. Ultrasound predicted anatomical lesion level within one level of the postnatal findings in 50% of the first cohort and 89% of the second cohort (P < 0.01). The level of the anatomical lesion as assessed by postnatal MRI differed from the functional lesion by as many as six vertebral levels. CONCLUSIONS Lesion level and head circumference on prenatal ultrasound are predictive of survival in children with spina bifida. No predictors were found for mental or motor function at the age of 5 years.
Collapse
|
9
|
Abstract
OBJECTIVE Our objective was to investigate the outcome of neonates with idiopathic polyhydramnios in the first year after birth. METHODS All patients diagnosed in the Erasmus Medical Centre Rotterdam and the University Medical Centre Utrecht between January 2000 and April 2005 with idiopathic polyhydramnios were studied. The outcome variables included mode of delivery, pre-term delivery, birth weight, macrosomia, large-for-gestational-age (weight > p90), neonatal or infant mortality and infant morbidity at 1 year after delivery. These were related to antenatal findings, including the onset of polyhydramnios and ultrasonographic evidence of macrosomia (estimated fetal weight > p90). RESULTS Polyhydramnios was diagnosed at a mean gestational age (+/- s.d.) of 31.0 +/- 4.9 weeks. The mean gestational age at birth (+/- s.d.) was 37.9 +/- 3.7 weeks. Macrosomia at birth was present in 25.3% (22/88). Sixty-three of 88 infants were in good health 1 year after birth; 20 infants had an abnormality and 5 children had died. Macrosomia and detection of polyhydramnios in the third trimester was associated significantly with a good outcome. CONCLUSION In neonates with idiopathic polyhydramnios, abnormalities were detected during the first year of life in 28.4%. Detection of polyhydramnios in the second trimester and low or normal birth weight are risk factors for associated abnormalities.
Collapse
|
10
|
Methods of sonographic cervical length measurement in pregnancy: A review of the literature. J Matern Fetal Neonatal Med 2009; 19:755-62. [PMID: 17190685 DOI: 10.1080/14767050600852601] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
In this review we give an overview of the methods and pitfalls in cervical length measurements. We compared the different techniques and investigated factors that influence visualization of the cervix. The data in this overview may be used to establish guidelines in clinical practice.
Collapse
|
11
|
Dynamic cervical length changes: Preliminary observations from 30-minute transvaginal ultrasound recordings. J Matern Fetal Neonatal Med 2009; 20:481-6. [PMID: 17674259 DOI: 10.1080/14767050701288267] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE The purpose of this study was to visualize and quantify dynamic changes in the cervix and to study factors influencing cervical length. METHODS Eighteen women with a gestational age between 23 and 40 weeks were examined by transvaginal ultrasound during a continuous observation period of 30 minutes. RESULTS All women delivered at >34 weeks of gestation, fourteen at term. The overall mean difference between the shortest and longest cervical length during the 30-minute recordings (cervical length variation) was 10.9 mm (range 1.6-26.7 mm). In the presence of fetal movements directed at the cervix, peristaltic movement of the bowel or contractions, cervical length variation was larger than in the absence of these conditions (mean 12.7 mm, range 5.2-26.7 mm and mean 6.1 mm, range 1.6-9.4 mm, respectively; p = 0.03). CONCLUSIONS Dynamic changes in cervical length are present at early gestation and long before delivery and can be observed either spontaneously or associated with contractions, fetal movements or peristalsis. These conditions must be considered as pitfalls in cervical length measurement. In critical cases, such as early threatened preterm labor, increases in the frequency and duration of sonographic ultrasound measurements may be helpful to obtain a more reliable estimation of the cervical status.
Collapse
|
12
|
Hydropic placenta as a first manifestation of twin-twin transfusion in a monochorionic diamniotic twin pregnancy. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2009; 28:375-378. [PMID: 19244075 DOI: 10.7863/jum.2009.28.3.375] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
13
|
Transvaginal ultrasound measurement of cervical length in the supine and upright positions versus Bishop score in predicting successful induction of labor at term. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2009; 33:213-220. [PMID: 19173229 DOI: 10.1002/uog.6219] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
OBJECTIVES To examine the predictive value of cervical length as measured by transvaginal sonography (TVS) in supine and upright maternal positions for the mode of delivery and induction-to-delivery interval after induction of labor at term, and to compare these measurements with the Bishop score and its predictive value. METHODS TVS for cervical length measurement in the supine and upright positions and digital examination of the cervix were performed in 68 nulliparous and 34 parous women before induction of labor at term. In assessing the predictive value of the Bishop score and TVS parameters for a vaginal delivery after labor induction only nulliparous women were included in the analysis, since all the parous women delivered vaginally. Both nulliparous and parous women were included in the analysis of the induction-to-delivery interval. The method of labor induction, oxytocin or prostaglandin, was determined on the basis of the pre-induction Bishop score. RESULTS Logistic regression analysis showed in nulliparous women that only the cervical length measured in the upright position was a significant predictor of the need for Cesarean section (odds ratio 1.14; 95% CI, 1.02-1.27). The areas under the receiver-operating characteristics curve in predicting the need for Cesarean section because of failure to progress were higher for the cervical length, both in supine and upright positions, than for the Bishop score (0.66, 0.68 and 0.46, respectively). Only the Bishop score correlated significantly with the induction-to-delivery interval in both nulliparous and parous women. However, this may have been due to a selection bias, as no significant correlation with Bishop score was found when the oxytocin and prostaglandin induction-to-delivery intervals were analyzed separately. CONCLUSION Our results suggest that maternal postural change might improve the accuracy of sonographically-measured cervical length for predicting a vaginal delivery after induction of labor at term. However, our results need to be confirmed in a larger and more homogeneous population.
Collapse
|
14
|
Isolated congenital atrioventricular block diagnosed in utero: natural history and outcome. J Matern Fetal Neonatal Med 2008; 21:469-76. [PMID: 18570127 DOI: 10.1080/14767050802052786] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Isolated congenital atrioventricular block (CAVB) diagnosed in utero is associated with a high morbidity and mortality. Prognosis is especially poor when heart rate drops below 55 beats per minute (bpm) and when fetal hydrops develops. We describe the natural history and outcome of 24 infants with isolated CAVB diagnosed in utero, review the literature, and assess the risk factors that could predict outcome. METHODS This was a retrospective multicenter study of 24 patients with isolated CAVB diagnosed in utero. RESULTS CAVB was detected at a mean gestational age (GA) of 24.7 +/- 5.1 weeks. Ten fetuses initially presented with complete heart block. Low heart rate or incomplete heart block was the first documentation of bradyarrhythmia in the other 14 fetuses. In 11 of them, CAVB developed during pregnancy after a median time of 3 (range 1-16) weeks. Fetal hydrops developed in 10 of 24 (42%) fetuses at a mean GA of 27.6 +/- 5.1 weeks. Hydropic fetuses showed lower heart rates during pregnancy (47 +/- 10 bpm) than non-hydropic fetuses (57 +/- 10 bpm). There were three intrauterine deaths; all were hydropic and female. Nine viable females and 12 males were born at a mean GA of 37.1 +/- 6.1 weeks with an average birth weight of 3097 +/- 852 g. Fifteen CAVB patients required pacemaker (PM) intervention, 10 of them immediately after birth. Dilated cardiomyopathy (DCM) developed in three infants of whom two died of congestive heart failure, shortly after the diagnosis was made; one is still alive. Mortality before or after birth was 21%, and was associated with heart rates below 50 bpm and development of fetal hydrops. Poor outcome, defined as death, PM implantation, or development of DCM, occurred in 83% of cases and was associated with heart rates below 60 bpm during pregnancy. CONCLUSIONS Isolated CAVB diagnosed in utero is associated with high morbidity and mortality. Patients who develop fetal hydrops show lower heart rates during pregnancy than patients who do not. A fetal heart rate below 50 bpm and development of fetal hydrops is associated with increased mortality. Rates below 60 bpm are associated with PM requirement and/or DCM.
Collapse
|
15
|
Transperineal versus transvaginal sonographic cervical length measurement in second- and third-trimester pregnancies. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 32:657-662. [PMID: 18816491 DOI: 10.1002/uog.4093] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE To investigate the reliability of, and patient satisfaction with, transperineal cervical length measurement during the third trimester of pregnancy and to compare these with measurement during the mid-trimester, using transvaginal sonographic imaging of the cervix as a reference. METHODS Women attending an outpatient clinic for cervical length measurement before 29 weeks or after 35 weeks of gestation were examined by transvaginal and transperineal ultrasound and the results compared. Preference for either method was indicated by both sonographers and patients. RESULTS Seventy-one patients participated in the study, 23 in the second and 48 in the third trimester of pregnancy. There was failure to obtain a clear image on transperineal ultrasound in 30% of mid-trimester pregnancies, and in 19% of third-trimester cases. Elevation of the patient's hips improved the image in five out of 10 women in whom the scan was repeated following a postural change. Transvaginal cervical length measurements could be obtained in all cases. There was a strong correlation between transvaginal and transperineal measured cervical length (Pearson's correlation coefficient = 0.85). Sonographers preferred transvaginal images of the cervix irrespective of whether they were obtained in the second or third trimester. Transperineal ultrasound was judged as not or mildly painful by most women, but transvaginal ultrasound was preferred. CONCLUSIONS Transvaginal ultrasound is the least painful, most feasible, and probably most accurate method with which to measure cervical length in the third trimester of pregnancy. Transperineal ultrasound is a feasible alternative, although its application in clinical practice is restricted by the need for an experienced sonographer.
Collapse
|
16
|
Lack of standardization in determining gestational age for prenatal screening. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 32:607-611. [PMID: 18720453 DOI: 10.1002/uog.5347] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVES To determine whether estimation of gestational age (GA) in the context of first-trimester Down syndrome screening is standardized in the Netherlands. METHODS This was a retrospective study, carried out between January 2005 and December 2006, of women who underwent first-trimester Down syndrome screening (n = 40,730) based on GA, maternal serum analysis and nuchal translucency (NT) measurement. Date of the last menstrual period (LMP), dating scan information including measurement of crown-rump length (CRL), NT thickness and name of the sonographer were recorded for all pregnancies. The accuracy of estimation of GA was evaluated by comparing the GA based on the LMP with that estimated from the CRL, using relevant subsets of the database. A survey of 104 sonographers was performed to further investigate the findings of the preceding analysis. RESULTS In 44% of all first-trimester combined tests the estimation of GA was based on the dating scan; the method of determination of GA was unknown in 23%. In 15% of all cases a dating scan was recorded but was not used to provide the estimation of GA at blood sampling. Detailed analysis showed that a consistent methodology for the estimation of GA from CRL was not maintained within hospitals and obstetric practices. For a single CRL, the reported GA differed by up to 10 days. Finally, it was demonstrated that individual sonographers reported different GAs for a given CRL. CONCLUSIONS Currently, estimation of GA in the first trimester in the Netherlands is not standardized. To improve the performance of prenatal screening for Down syndrome, estimation of GA should be based on ultrasound examination, with one nationally accepted CRL curve.
Collapse
|
17
|
Sonographic longitudinal cervical length measurements in nulliparous women at term: prediction of spontaneous onset of labor. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 32:652-656. [PMID: 18702094 DOI: 10.1002/uog.5291] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE The aim of this study was to predict spontaneous onset of labor by serial transvaginal ultrasound measurement of cervical length (CL) in a homogeneous population of nulliparous women at term. METHODS 162 nulliparous women with singleton fetuses in cephalic presentation were examined at weekly intervals from 36 weeks' gestation to delivery. CL was measured by transvaginal ultrasound in the supine and upright positions. RESULTS There was a significant decrease in CL in the last 12 days prior to delivery. However, this decrease was small with substantial variation between individuals. Women with spontaneous onset of labor could be divided into three different groups: those with unchanged CL before delivery; those with a fall in CL in the last 2 weeks prior to delivery; and those with a gradual change in CL starting before the last 2 weeks prior to delivery. A single CL measurement below 30 mm between 37 and 38 weeks of gestation predicted spontaneous onset of labor before 41 weeks' gestation with a sensitivity of 46%, specificity of 78%, positive predictive value (PPV) of 82%, negative predictive value (NPV) of 40% in the supine position; and sensitivity of 53%, specificity of 72%, PPV of 81%, NPV of 40% in the upright position. CONCLUSION Between 37 and 38 weeks' gestation, spontaneous onset of labor before 41 weeks can be predicted by a CL measurement, but with low sensitivity and NPV. Inter-individual variations in CL and in CL changes are large, which hampers the value of single and repeated CL measurements for the prediction of spontaneous onset of labor at term.
Collapse
|
18
|
'Tobacco pipe' sign in the fetus: patent left superior vena cava with absent right superior vena cava. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 32:593-594. [PMID: 18690613 DOI: 10.1002/uog.5392] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
19
|
Neurological outcome in isolated congenital heart block and hydrops fetalis. Fetal Diagn Ther 2007; 22:457-61. [PMID: 17652937 DOI: 10.1159/000106355] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2006] [Accepted: 09/13/2006] [Indexed: 11/19/2022]
Abstract
OBJECTIVE Isolated fetal heart block (HB), a condition associated with fetal hydrops, carries a high mortality rate and may result in neurodevelopmental sequelae. To the best of our knowledge, no data exist regarding the long-term outcome of such hydropic fetuses. We reviewed our experience with this condition to determine the neurodevelopmental outcome of prenatally diagnosed cases with isolated HB complicated by hydrops fetalis. METHODS Neurodevelopmental assessment of 5 children presented prenatally with isolated HB associated with hydrops fetalis. RESULTS During the last 18 years, 10 cases were detected prenatally with isolated HB and hydrops fetalis. 3 of the 10 fetuses died in utero, and 2 died postnatally, due to a dilated cardiomyopathy, at the age of 9 months and 4 years, respectively. Neurodevelopmental studies done on the 5 remaining children were normal. CONCLUSION Long-term neurodevelopmental assessments of 5 surviving cases presented prenatally with isolated HB and hydrops fetalis are reassuring.
Collapse
|
20
|
Aortico-Right Ventricular Tunnel: Prenatal Diagnosis Leading to Neonatal Survival. Fetal Diagn Ther 2007; 22:335-8. [DOI: 10.1159/000103291] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2006] [Accepted: 07/14/2006] [Indexed: 11/19/2022]
|
21
|
Sonographic longitudinal cervical length measurements in nulliparous women at term; prediction of spontaneous onset of labour. Z Geburtshilfe Neonatol 2007. [DOI: 10.1055/s-2007-1002958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
22
|
Prediction of the outcome of labour induction at term by transvaginal ultrasound in supine and upright position. Z Geburtshilfe Neonatol 2007. [DOI: 10.1055/s-2007-1002959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
23
|
|
24
|
Transient Non-Autoimmune Fetal Heart Block. Fetal Diagn Ther 2005; 20:81-5. [PMID: 15692198 DOI: 10.1159/000082427] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2003] [Accepted: 01/07/2004] [Indexed: 11/19/2022]
Abstract
OBJECTIVES Fetal heart block is a rare and irreversible condition associated with structural heart defects or maternal autoantibodies (SS-A/Ro and SS-B/La) resulting in permanent damage of the atrioventricular (AV) node. This is the first report of 4 cases with a transient fetal heart block in structurally normal hearts without maternal autoantibodies. METHODS A report on 4 patients seen within a 14-year period at one center with fetal heart block without intracardiac abnormalities or maternal autoantibodies. RESULTS Three patients were referred to our center with a fetal bradycardia (heart rate 70-85 bpm), between 20 and 33 weeks' gestational age, and 1 for a 'triple' test at 16 weeks' gestational age. Echocardiography showed a complete heart block in 2 fetuses, and a second-degree AV block in the other 2. Heart block had completely resolved at all following visits. Postnatal ECG recordings showed normal sinus rhythm in all patients. Echocardiographic evaluation at presentation and follow-up showed normal cardiac anatomy, without signs of hydrops or cardiac decompensation in all patients. All mothers tested negative on SS-A/Ro and SS-B/La autoantibodies. CONCLUSIONS Fetal heart block can occur in the absence of structural heart defects and maternal autoantibodies to SS-A/Ro and SS-B/La. The origin of such heart block is unknown, but its course seems benign: none of the patients ever showed ventricular heart rates <55 bpm, signs of congestive heart failure or fetal hydrops. Heart block resolved spontaneously in all patients.
Collapse
|
25
|
Abstract
BACKGROUND AND METHODS In six hydrocephalic foetuses (gestational age 29-38 wk), proton MR spectroscopy (1H-MRS) was performed in the basal ganglia for detection of lactate in vivo. RESULTS Lactate was present in two foetal brains, absent in two and not detectable because of movement in two. CONCLUSION With adequate immobilization of the foetus, 1H-MRS can be used for detection of foetal brain lactate.
Collapse
|
26
|
Treatment of fetal heart block with maternal steroid therapy: case report and review of the literature. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2004; 24:467-472. [PMID: 15343606 DOI: 10.1002/uog.1713] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The presence of maternal autoantibodies to SS-A/Ro and/or SS-B/La is associated with the development of fetal heart block. There are data suggesting that maternal treatment with steroids might reverse heart block. We report on a pregnancy in a mother with secondary Sjögren syndrome and systemic lupus erythematosus with presence of autoantibodies to SS-A/Ro and SS-B/La, which was complicated by the development of incomplete fetal heart block. Oral dexamethasone treatment could not prevent progression to complete heart block and was associated with a number of complications.A review of the literature revealed 19 studies (including ours) in which 93 cases of fetal heart block were treated with maternal steroid therapy. Complete heart block proved irreversible in all cases; and of 13 fetuses with incomplete heart block which received maternal steroid therapy, three had a reduction in their degree of block and one reverted to sinus rhythm. Maternal steroid therapy, initiated early in pregnancy and potentially preventing the onset of heart block, did not decrease the incidence of heart block in nine studies with 43 cases. Furthermore, the literature review revealed numerous serious side effects of maternal steroid administration during pregnancy. Data on these potential side effects are lacking in the 28 studies discussed in this review. Maternal dexamethasone therapy to prevent or treat fetal heart block remains, in our opinion, a questionable intervention and can as yet not be recommended in the clinical situation.
Collapse
|
27
|
Neurological outcome of children who were treated for fetal tachycardia complicated by hydrops. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2004; 24:154-158. [PMID: 15287052 DOI: 10.1002/uog.1106] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
OBJECTIVE Fetal tachycardia is a condition associated with congestive heart failure and development of fetal hydrops, which may result in neurological morbidity and mortality. The aim of this study was to investigate the long-term outcome of hydropic fetuses. METHODS This was a retrospective study on cognitive and neurological functioning of 11 infants, aged 6 months to 12 years, who experienced fetal tachycardia complicated by hydrops. RESULTS Seven fetuses had supraventricular tachycardia (SVT), three had atrial flutter (AF) and one had ventricular tachycardia (VT). Nine fetuses converted to sinus rhythm within a mean time of 8.2 days of presentation; resolution of hydrops was achieved in six of these patients in a mean time of 8.8 days. Mean gestational age (GA) at birth was 35 + 4 weeks. Neonatal cranial ultrasound was normal in seven infants and all but one of these were normal at follow-up: one infant who initially had no abnormalities developed multiple cerebral lesions as a result of a malignant long QT syndrome (LQTS) and died at the age of 2 years. Three infants had periventricular echogenicity (PVE) on neonatal cranial ultrasound, associated with a pseudocyst in one infant. The remaining infant showed a parenchymal hemorrhage of antenatal onset, seen as a porencephalic cyst at birth. One of these infants was normal at follow-up, one died 2 days after birth and two infants had neurological abnormalities at follow-up, consisting of mild hemiplegia with normal cognitive function in one, and a cognitive developmental delay in the other. CONCLUSIONS In this study, neurological outcome was good in eight out of 11 infants. Initiation of therapy should not be withheld or delayed on the assumption of poor neurological outcome.
Collapse
|
28
|
1171-199 Neurological outcome of fetal arrhythmias complicated by hydrops. J Am Coll Cardiol 2004. [DOI: 10.1016/s0735-1097(04)91661-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
29
|
Abstract
OBJECTIVES The aim of this study was to investigate the pharmacokinetics and pharmacodynamics of sotalol in the treatment of fetal tachycardia. BACKGROUND Maternally administered, intrauterine therapy of fetal tachycardia is dependent on the transplacental passage of the antiarrhythmic agent. METHODS In a prospective study of patients treated for fetal tachycardia with sotalol, concentrations of sotalol were determined in maternal and umbilical blood and in amniotic fluid, and the relationship between these concentrations and the occurrence of conversion to sinus rhythm was investigated. RESULTS Eighteen fetal patients were studied, nine with atrial flutter and nine with supraventricular tachycardia. Fourteen were treated with sotalol; 13 converted to sinus rhythm, of whom 2 relapsed. There was one intrauterine death. Four patients were treated with sotalol and digoxin, of whom two were treated successfully. Mean birth weight was 3,266 g. The daily maternal sotalol dose was linearly related to the maternal plasma concentration. The mean fetal/maternal sotalol plasma concentration was 1.1 (range 0.67 to 2.87, SD 0.63), and the mean amniotic fluid/fetal blood ratio of sotalol was 3.2 (range 1.28 to 5.8, SD 1.4). The effectiveness of sotalol therapy could not be extrapolated from maternal blood levels. CONCLUSIONS Sotalol is a potent antiarrhythmic agent in the treatment of fetal tachycardia. The placental transfer is excellent. Sotalol accumulates in amniotic fluid but not in the fetus itself. Therefore it seems that renal excretion in the fetus is efficient and greater than the oral absorption by fetal swallowing. The maternal blood level is not a reliable predictor of the chances of success of therapy. Sotalol is not associated with fetal growth restriction.
Collapse
|
30
|
Abstract
OBJECTIVES To review our 13-year experience with prenatally detected hypoplastic left heart syndrome (HLHS) of which management remains controversial. MATERIAL AND METHODS Retrospective study of the management and outcome in all cases of HLHS diagnosed prenatally in a tertiary referral center for pediatric cardiology and cardiac surgery between January 1988 and July 2001. RESULTS The diagnosis of HLHS was made in 32 fetuses. One mother had two pregnancies associated with HLHS. In 16 cases parents opted for termination of pregnancy and in five for compassionate care. Four fetuses died in utero, and seven patients received a palliative reconstructive Norwood procedure. In seven fetuses, associated anomalies were detected: three chromosomal and structural and four only structural. In six fetuses, other associated intracardiac anomalies were detected. Of seven infants operated, six had no associated anomalies and only one is alive at an age of 17 months. CONCLUSION The low percentage of intention to treat among patients in our center (34%) is in accordance with the percentage found in another study from the UK (36.2%), but differs significantly from reported series across the Atlantic (67%). Prenatal diagnosis of the HLHS provides opportunities not only for getting patients in optimal preoperative condition when surgery is offered, but also for in-depth counseling of the parents on this severe malformation. A minority of parents faced with the difficult decision of possible termination of pregnancy, compassionate care or the Norwood strategy, choose surgical treatment which might be based on socioreligious differences and the interpretation of the long-term quality of life.
Collapse
|
31
|
Abstract
BACKGROUND Persistent junctional reciprocating tachycardia (PJRT) tends to be a persistent arrhythmia and requires aggressive therapeutic management. Diagnosis and management of this infrequently occurring tachycardia in the fetus at an early stage is of importance for the prevention of congestive heart failure (CHF). METHODS A retrospective study of four fetuses with supraventricular tachycardia (SVT) of the PJRT type was performed. RESULTS All had sustained SVT (mean of 228 beats/min) at a mean gestational age of 34 + 5 weeks, with CHF present in two. Three fetuses had prenatal characteristics of PJRT on M-mode echocardiography with a ventriculoatrial (VA)/atrioventricular ratio of > 1 on M-mode echocardiography suggesting a slow conducting accessory pathway. All four fetuses had postnatal confirmation of the diagnosis. Transplacental treatment with flecainide was effective in one patient; sotalol as a single drug or in combination with digoxin was partially effective in the remaining three. Two developed sinus rhythm, with short intermittent periods of tachycardia and decreasing signs of CHF; one case showed a minimal decrease in heart rate. Oral propranolol therapy converted two patients postnatally; in the remaining two patients radiofrequency ablation was performed at the age of 5 months and 6 years. CONCLUSIONS The characteristics of our prenatal PJRT cases included a sustained heart rate not exceeding 240 beats/min with a long VA interval, the presence of CHF and therapy resistance. Transplacental treatment should be initiated, possibly with a combination of sotalol and digoxin in non-hydropic cases, or flecainide, especially in case of fetal hydrops. Pharmacological therapy is to be preferred postnatally, but radiofrequency ablation seems to be indicated in therapy-resistant cases with CHF, even in the first months of life.
Collapse
|
32
|
[Correlation between prenatal ultrasound diagnosis and findings from autopsies or neonatal operations due to structural congenital heart defects; a retrospective analysis]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2002; 146:2297-302. [PMID: 12497759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/28/2023]
Abstract
OBJECTIVE To determine the contribution of the prenatal ultrasound diagnosis of structural congenital heart defects to the care of patients requiring surgery for their condition in the neonatal period. DESIGN Retrospective. METHOD During the period January 1991-June 1999, data were collected from two groups of children. One group had a structural heart defect diagnosed prenatally and the other underwent a neonatal operation due to a heart defect. In the prenatal group, the management and follow-up were analysed, whilst in the surgery group, the extent to which ultrasound investigation had been performed and whether there was a relationship between prenatal diagnosis and the severity of acidosis were analysed. RESULTS A structural heart defect was found through prenatal ultrasound in 170 children and 64% of these prenatally diagnosed patients died before or immediately after birth, or the pregnancy was aborted. 14% underwent surgery within 31 days post partum. This last category formed an overlap with the surgery group. The surgery group contained 191 patients, who required surgery in the neonatal period, including 24 from the prenatal group. In total, 87% had no prenatal diagnosis. In the group with a prenatal diagnosis pre-operative lactate values were significantly lower. CONCLUSION The heart defect was only diagnosed prenatally in 13% of the patients from the surgery group, although this would have been technically feasible in 46%. Better prenatal diagnosis of heart disease could contribute to a better counselling of parents in their choice between abortion, conservative treatment or emergency surgery. In the case of emergency surgery, prenatal detection might lead to a decrease in morbidity and mortality.
Collapse
|
33
|
Abstract
The pharmacological treatment of fetal tachycardia (FT) has been described in various publications. We present a study reviewing the necessity for treatment of FT, the regimens of drugs used in the last two decades and their mode of administration. The absence of reliable predictors of fetal hydrops (FH) has led most centers to initiate treatment as soon as the diagnosis of FT has been established, although a small minority advocate nonintervention. As the primary form of pharmacological intervention, oral maternal transplacental therapy is generally preferred. Digoxin is the most common drug used to treat FT; however, effectiveness remains a point of discussion. After digoxin, sotalol seems to be the most promising agent, specifically in atrial flutter and nonhydropic supraventricular tachycardia (SVT). Flecainide is a very effective drug in the treatment of fetal SVT, although concerns about possible pro-arrhythmic effects have limited its use. Amiodarone has been described favorably, but is frequently excluded due to its poor tolerability. Verapamil is contraindicated as it may increase mortality. Conclusions on other less frequently used drugs cannot be drawn. In severely hydropic fetuses and/or therapy-resistant FT, direct fetal therapy is sometimes initiated. To minimize the number of invasive procedures, fetal intramuscular or intraperitoneal injections that provide a more sustained release are preferred. Based on these data we propose a drug protocol of sotalol 160 mg twice daily orally, increased to a maximum of 480 mg daily. Whenever sinus rhythm is not achieved, the addition of digoxin 0.25 mg three times daily is recommended, increased to a maximum of 0.5 mg three times daily. Only in SVT complicated by FH, either maternal digoxin 1 to 2mg IV in 24 hours, and subsequently 0.5 to 1 mg/day IV, or flecainide 200 to 400 mg/day orally is proposed. Initiating direct fetal therapy may follow failure of transplacental therapy.
Collapse
|
34
|
Lactacidosis in the neonate is minimized by prenatal detection of congenital heart disease. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2002; 19:552-555. [PMID: 12047532 DOI: 10.1046/j.1469-0705.2002.00714.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVES To investigate the impact of prenatal detection of congenital heart disease on preventing severe preoperative lactacidosis. DESIGN Patients operated upon for congenital heart disease during the first 31 days of life (n = 209) were studied retrospectively, 21 were diagnosed prenatally and 188 patients had not been diagnosed prenatally. Preoperative lactate, pH and base excess were evaluated. RESULTS Differences were noted in preoperative pH (7.28 +/- 0.03 vs. 7.24 +/- 0.01, P = 0.29), base excess (-5.83 +/- 0.64 vs. -6.93 +/- 0.46 mmol/L, P = 0.10) and lactate (3.05 +/- 0.35 vs. 6.08 +/- 0.45 mmol/L, P < 0.001), indicating a significant difference in blood lactate values in favor of the prenatally diagnosed group. CONCLUSIONS Prenatal diagnosis of congenital heart disease and the resulting immediate postnatal care prevent lactate increase in the preoperative period of these patients. This may decrease the risk of cerebral damage and result in the patient being in better condition at surgery.
Collapse
|
35
|
Eyes on the Lab. Lab Med 2001. [DOI: 10.1309/ptd3-rr2l-8wbq-7ddv] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
36
|
[Aneurysm of the V. magna cerebri (vein of Galen), a cause of congestive heart failure in five neonates]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2001; 145:1602-5. [PMID: 11534379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
In five neonates (4 girls and 1 boy) with aneurysm of the V. magna cerebri, clinical signs of congestive heart failure were encountered. In three of the neonates the symptoms were detected postnatally and in two prenatally. In one of the prenatally detected cases the aneurysm was treated by embolisation during the first week of life. Upon follow-up at six years of age, this patient's situation was stable but hydrocephalus had led to poor visuomotor development, mild motor retardation and mental retardation. In the other infants, medicinal treatment of the congestive heart failure was discontinued in view of ischaemic brain damage, and these patients subsequently died. Congestive heart failure often develops in neonates with an aneurysm of the V. magna cerebri due to low cerebrovascular resistance. A continuous murmur over the skull is pathognomonic for this condition.
Collapse
|
37
|
Abstract
We report three siblings from consecutive pregnancies affected with restrictive dermopathy (RD). During the second pregnancy, fetal behavioural development and growth were studied extensively using ultrasound at 1-4 week intervals. Dramatic and sudden changes occurred in fetal body movements and growth but not until the end of the second trimester of pregnancy. Prominent at that time were prolonged periods of fetal quiescence and very low heart rate variability, together with abnormally executed body movements of short duration. Retarded femoral development and jerky abrupt fetal body movements (abnormal movement quality) were already present in the early second trimester of pregnancy. Facial anomalies emerged despite the presence of fetal mouth movements. The clinical features of RD were only partly explained by present knowledge of skin development and the fetal akinesia deformation sequence hypothesis. Quantitative assessment of fetal movements proved to be a poor early marker for antenatal diagnosis of this disorder.
Collapse
|
38
|
[Protocols for the treatment of supraventricular tachycardias in the fetus]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2001; 145:1218-9. [PMID: 11447879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
The protocols mentioned are used by Utrecht University Hospital for the treatment of foetal supraventricular tachycardias. In the case of atrial flutters the pregnant woman is treated with sotalol administered orally and, if no sinus rhythm is obtained nor a reduced ventricular rhythm occurs, subsequently with digoxin. If there is no hydrops foetalis then this is also the treatment regimen for other forms of foetal supraventricular tachycardia. In the case of hydrops foetalis the treatment is more aggressive: digoxin intravenously or flecanide orally; if the rhythm does not convert into a sinus rhythm nor a reduced ventricular rhythm occurs then both of these medications are administered; if that also proves to be insufficient then direct foetal therapy can be considered.
Collapse
|
39
|
Prenatal diagnosis of congenital heart disease affects preoperative acidosis in the newborn patient. J Thorac Cardiovasc Surg 2001; 121:798-803. [PMID: 11279423 DOI: 10.1067/mtc.2001.112825] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVES Congenital heart disease is the leading cause of death in the first year after birth. Prenatal diagnosis of the disease can optimize the preoperative condition of the patient and may help in the prevention of acidosis. In this retrospective study we compared the occurrence of metabolic acidosis in patients with and without prenatal diagnosis of a congenital heart disease. METHODS Data of 408 patients who needed an operation for congenital heart disease within 31 days of life were analyzed retrospectively. Arterial blood gases at fixed time intervals and worst blood gas of 81 patients with and 327 patients without a prenatal diagnosis were compared, categorizing the patients on ductus dependency, anticipated univentricular or biventricular repair, and left-sided, right-sided, or no heart obstruction. RESULTS In the overall group significant differences in lowest pH, lowest base excess, and highest lactate level were found, with metabolic acidosis more common among the patients with a postnatal diagnosis. In the group of patients with ductus-dependent congenital heart disease, the difference between patients receiving a prenatal and those receiving a postnatal diagnosis was more significant than in the group with non-ductus-dependent lesions. Analyzing patients with right-sided, left-sided, and no obstruction separately, significant differences were found in the group with left-sided heart obstruction for lowest pH and base excess and in the group with right-sided heart obstruction for lowest base excess. CONCLUSIONS Prenatal diagnosis of congenital heart disease minimizes metabolic acidosis in patients with congenital heart disease and may be associated with improved long-term outcome and prevention of cerebral damage among this fragile group of patients, although no significant effect on direct surgical outcome was encountered.
Collapse
|
40
|
[Diagnostic value of prenatal MRI in fetus with intracranial anomalies diagnosed by ultrasonography]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2001; 145:179-84. [PMID: 11213565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
OBJECTIVE To determine the value of prenatal MRI in the third trimester in the foetus with intracranial lesions established by ultrasonography. DESIGN Descriptive. METHOD During a period of one year, prenatal MRI was performed in 12 patients after ultrasonography had revealed intracranial lesions in the foetus. Postnatally, ultrasonography, MRI or postmortem examination of the brain was performed in 11 children. The MRI examination was carried out in a 1.5 Tesla field. Rapid, T2-weighted images were obtained. To immobilize the child, the pregnant women were sedated. RESULTS In 5 cases, prenatal ultrasonography and prenatal MRI resulted in the same diagnosis. In seven cases, MRI provided more information. Postnatal examination confirmed the prenatal diagnosis in 10 of the 11 cases. In one case, maceration rendered supplementary examination impossible. CONCLUSION MRI may be regarded as a valuable alternative diagnostic aid if prenatal ultrasonography is incomplete or the findings are uncertain or limited.
Collapse
|
41
|
[Congenital infection: diagnostic serology of the mother not always definitive]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2001; 145:153-6. [PMID: 11213556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
In 2 infants, a girl and a boy, congenital viral infection was diagnosed in the neonatal period. The prenatal examination (serologic investigation for Toxoplasma gondii, rubella virus, cytomegalovirus, herpes simplex virus and syphilis (TORCHES)) was negative. In both cases prenatal ultrasonography was abnormal and suggested intrauterine infection. The infants were born with typical symptoms of multisystem disease, known as symptomatic congenital cytomegalovirus infection (jaundice, petechiae, hepatosplenomegaly, intrauterine growth retardation, microcephaly and cerebral calcifications) and congenital rubella syndrome (intrauterine growth retardation, congenital heart disease, cataract, hepatosplenomegaly and cerebral calcifications), respectively. Both had severe cerebral damage. To diagnose severe congenital infection in the first trimester of pregnancy in presence of congenital anomalies in utero there are other possible methods than TORCHES investigation, such as polymerase chain reaction and virus culture in amniotic fluid or in foetal blood obtained by cord puncture.
Collapse
|
42
|
Abstract
BACKGROUND Fetal tachycardia may cause hydrops fetalis and lead to fetal death. No unanimity of opinion exists regarding the optimum treatment. This study evaluates our experience with transplacental sotalol therapy to treat fetal tachycardias in terms of safety and efficacy. METHODS AND RESULTS The charts of 21 patients who were treated with sotalol for fetal tachycardia were reviewed. Ten fetuses had atrial flutter (AF), 10 had supraventricular tachycardia (SVT), and 1 had VT. Hydrops fetalis was present in 9 fetuses. Drug treatment was successful in establishing sinus rhythm in 8 of 10 fetuses with AF and in 6 of 10 fetuses with SVT. The mortality rate in this study was 19% (4 of 21 fetuses; 3 had SVT and 1 had AF); 3 deaths occurred just days after the initiation of sotalol therapy, and 1 occurred after a dosage increase. At birth, tachycardia was present in 6 infants. Two patients who converted to sinus rhythm in utero suffered from neurologic pathology postnatally. CONCLUSIONS Fetal tachycardia is a serious condition in which treatment should be initiated, especially in the presence of hydrops fetalis. The high success rate in fetuses with AF suggests that sotalol should be considered a drug of first choice to treat fetal AF. The low conversion rate and the fact that 3 of the 4 deaths in this study occurred in fetuses with SVT indicate that the risks of sotalol therapy outweigh the benefits in this group and that sotalol should, therefore, be limited in the treatment of fetal SVT.
Collapse
|
43
|
First trimester nuchal anomalies as a prenatal sign of Zellweger syndrome. Prenat Diagn 2000; 20:520-1. [PMID: 10861722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
44
|
Abstract
OBJECTIVES The aim of this retrospective study was to evaluate perinatal atrial flutter (AF) and the efficacy of maternally administered antiarrhythmic agents, postpartum management and outcome. BACKGROUND Perinatal AF is a potentially lethal arrhythmia, and management of this disorder is difficult and controversial. METHODS Forty-five patients with documented AF were studied retrospectively. RESULTS Atrial flutter was diagnosed prenatally in 44 fetuses and immediately postnatally in 1 neonate. Fetal hydrops was seen in 20 patients; 17 received maternal therapy, 2 were delivered and 1 was not treated because it had a severe nontreatable cardiac malformation. In the nonhydropic group of 24 patients, 18 were treated and the remaining 6 were delivered immediately. In the hydropic group, 10 received single-drug therapy (digoxin or sotalol) and 7 received multidrug therapy. In the nonhydropic group, 13 received a single drug (digoxin or sotalol) and 5 received multiple drugs. One patient with rapid 1:1 atrioventricular conduction (heart rate 480 beats/min) died in utero and another died due to a combination of severe hydrops because of the AF, sotalol medication, stenosis of the venous duct and hypoplastic placenta. Of the 43 live-born infants, 12 were in AF at birth. Electrical cardioversion was successful in eight of nine patients. No recurrences in AF have occurred beyond the neonatal period. Four patients with fetal flutter and hydrops showed significant neurological pathology immediately after birth. CONCLUSIONS Fetal AF is a serious and threatening rhythm disorder, particularly when it causes hydrops, it may be associated with fetal death or neurological damage. Treatment is required and primarily aimed at reaching an adequate ventricular rate and preferably conversion to sinus rhythm. Digoxin failed in prevention of recurrence at time of delivery in a quarter of our patients, whereas with sotalol no recurrence of AF has been reported, suggesting that class III agents may be the future therapy. Once fetuses with AF survive without neurological pathology, their future is good and prophylaxis beyond the neonatal period is unnecessary.
Collapse
|
45
|
Isochromosome 1q as the sole chromosomal abnormality in two fetal teratomas. Possible trisomic or tetrasomic zygote rescue in fetal teratoma with an additional isochromosome 1q. CANCER GENETICS AND CYTOGENETICS 1999; 115:1-10. [PMID: 10565292 DOI: 10.1016/s0165-4608(99)00049-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
An isochromosome of the long arm of chromosome 1 leading to tetrasomy 1q was detected as the sole chromosomal aberration in two cases of fetal teratoma arising from the oral cavity. This type of teratoma is extremely rare and has seldom been investigated cytogenetically. Studies of DNA markers in the tumor, normal fetal skin, and parental cells demonstrated that in both cases the additional 1q material was of maternal origin. In one of the patients, the teratoma had maternal 1q marker alleles that were not found in the fetal body cells. This implies that the tumor was not derived in a direct way from the fetal body tissue; instead, the chromosomally-normal fetus might be the result of some trisomic or tetrasomic zygote rescue mechanism.
Collapse
|
46
|
[Discordant fetal growth in multiple pregnancy: intervention should be based on chorionicity]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 1999; 143:1889-90. [PMID: 10526604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
|
47
|
[Third circulation: twin transfusion syndrome]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 1999; 143:1022-7. [PMID: 10368727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
The estimated incidence in the Netherlands of serious previable twin-to-twin transfusion syndrome is 50-100 cases per year. The polyhydramnion-oligohydramnion sequence is the most prominent feature. Prognosis without treatment is dismal: previable preterm birth. Risk of serious morbidity in the surviving twin in case of foetal demise of the other is impressive. Once the diagnosis of monochorionicity has been made in the first trimester, detailed ultrasound examination is mandatory for early recognition of the development of the syndrome, as therapeutic options exist. Therapeutic options include piercing of the intertwin membrane, repeated amniocenteses or laser occlusion of the chorionic vasculature. In seven Dutch centres over three years time 61 cases were identified: 36 needed intervention; 63 (of the 122) children survived, 10 with longterm morbidity.
Collapse
|
48
|
Neurological morbidity after fetal supraventricular tachyarrhythmia. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 1999; 13:43-47. [PMID: 10201085 DOI: 10.1046/j.1469-0705.1999.13010043.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
BACKGROUND Fetal tachyarrhythmia is a well-documented entity which, in the absence of pharmacological intervention, may lead to congestive heart failure, fetal hydrops and eventually fetal demise. The success rate of the implemented treatment is generally measured by survival and achievement of control of the arrhythmia. We report on the occurrence of associated cerebral damage in three patients with fetal tachycardia. METHODS We describe three patients with a history of fetal supraventricular tachyarrhythmia who developed cerebral complications in utero. RESULTS Two patients had cerebral hypoxic-ischemic lesions and one had hemorrhagic lesions present at birth. They had developed severe congestive heart failure and fetal hydrops secondary to fetal tachyarrhythmia, and there were no other obvious causes for the cerebral pathology. Two of these patients were referred to us antenatally. Therapy was instituted and resulted in control of the tachycardia and resolution of hydrops. The third patient was referred to our clinic shortly after birth because of severe circulatory problems secondary to fetal tachyarrhythmia. CONCLUSION From these observations, we believe that a fetus with tachyarrhythmia and subsequent hydrops is at increased risk for the development of cerebral complications, due to the circulatory disturbances and sudden changes in heart rate which may lead to fluctuations in cerebral perfusion. This would imply that it is of the utmost importance to aim at immediate and complete control of the heart rate in the treatment of fetal tachyarrhythmia.
Collapse
|
49
|
Prenatal and postnatal investigation of a case with Miller-Dieker syndrome due to a familial cryptic translocation t(17;20) (p13.3;q13.3) detected by fluorescence in situ hybridization. Prenat Diagn 1997; 17:173-9. [PMID: 9061768 DOI: 10.1002/(sici)1097-0223(199702)17:2<173::aid-pd30>3.0.co;2-v] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We present here a case report of a fetus with a kidney anomaly and dilated occipital horns, detected initially by echoscopy at 29 weeks' amenorrhoea. After 31 weeks of gestation, the proband was born with clinical symptoms of Miller-Dieker syndrome. This was subsequently confirmed by fluorescence in situ hybridization (FISH), but not by conventional cytogenetic analysis. FISH using a cocktail of cosmids (c197-2, c197-4, c197-9) from the Miller-Dieker critical region showed a deletion of 17p13.3 in one homologue of chromosome 17. Additional FISH studies revealed a subtle 17p;20q translocation in the father, his sister, and the paternal grandmother. Hence, our patient is a carrier of an unbalanced 17;20 translocation resulting in a partial deletion of 17p and a partial trisomy 20q. Whenever kidney anomalies and dilated occipital horns are observed together with polyhydramnios during prenatal ultrasound examination, the possibility of Miller-Dieker syndrome should be suspected. In such cases, prenatal and/or postnatal chromosome studies should also include FISH analysis with the appropriate probes.
Collapse
MESH Headings
- Abnormalities, Multiple/diagnostic imaging
- Abnormalities, Multiple/genetics
- Brain/abnormalities
- Chromosomes, Human, Pair 17
- Chromosomes, Human, Pair 20
- Female
- Gene Deletion
- Gestational Age
- Humans
- In Situ Hybridization, Fluorescence
- Infant, Newborn
- Kidney/abnormalities
- Kidney/diagnostic imaging
- Male
- Occipital Lobe/abnormalities
- Occipital Lobe/diagnostic imaging
- Pedigree
- Pregnancy
- Syndrome
- Translocation, Genetic
- Trisomy
- Ultrasonography, Prenatal
Collapse
|
50
|
Abstract
We report on a case of generalized mosaicism for trisomy 22. At chorionic villus sampling (CVS) in the 37th week of pregnancy, a 47,XX,+22 karyotype was detected in all cells. The indication for CVS was severe unexplained symmetrical intrauterine growth retardation (IUGR) and a ventricular septal defect (VSD) was noted. In cultured cells from amniotic fluid taken simultaneously, only two out of ten clones were trisomic. At term, a growth-retarded girl with mild dysmorphic features was born. Lymphocytes showed a normal 46,XX[50] karyotype; both chromosomes 22 were maternal in origin (maternal uniparental disomy). Investigation of the placenta post-delivery using fluorescence in situ hybridization showed a low presence of trisomy 22 cells in only one out of 14 biopsies. In cultured fibroblasts of skin tissue, a mosaic 47,XX,+22[7]/46,XX[25] was observed. Clinical follow-up is given up to 19 months.
Collapse
|