1
|
Effect of sequential release of sirolimus and rosuvastatin using silk fibroin microneedle to prevent intimal hyperplasia. Biomed Pharmacother 2023; 168:115702. [PMID: 37837879 DOI: 10.1016/j.biopha.2023.115702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/03/2023] [Accepted: 10/10/2023] [Indexed: 10/16/2023] Open
Abstract
Intimal hyperplasia (IH) is a major cause of vascular restenosis after bypass surgery, which progresses as a series of processes from the acute to chronic stage in response to endothelial damage during bypass grafting. A strategic localized drug delivery system that reflects the pathophysiology of IH and minimizes systemic side effects is necessary. In this study, the sequential release of sirolimus, a mechanistic target of rapamycin (mTOR) inhibitor, and statin, an HMG-COA inhibitor, was realized as a silk fibroin-based microneedle device in vivo. The released sirolimus in the acute stage reduced neointima (NI) and vascular fibrosis through mTOR inhibition. Furthermore, rosuvastatin, which was continuously released from the acute to chronic stage, reduced vascular stiffness and apoptosis through the inactivation of Yes-associated protein (YAP). The sequential release of sirolimus and rosuvastatin confirmed the synergistic treatment effects on vascular inflammation, VSMC proliferation, and ECM degradation remodeling through the inhibition of transforming growth factor (TGF)-beta/NF-κB pathway. These results demonstrate the therapeutic effect on preventing restenosis with sufficient vascular elasticity and significantly reduced IH in response to endothelial damage. Therefore, this study suggests a promising strategy for treating coronary artery disease through localized drug delivery of customized drug combinations.
Collapse
|
2
|
Prolonged hydrogen production by engineered green algae photovoltaic power stations. Nat Commun 2023; 14:6768. [PMID: 37880242 PMCID: PMC10600337 DOI: 10.1038/s41467-023-42529-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 10/13/2023] [Indexed: 10/27/2023] Open
Abstract
Interest in securing energy production channels from renewable sources is higher than ever due to the daily observation of the impacts of climate change. A key renewable energy harvesting strategy achieving carbon neutral cycles is artificial photosynthesis. Solar-to-fuel routes thus far relied on elaborately crafted semiconductors, undermining the cost-efficiency of the system. Furthermore, fuels produced required separation prior to utilization. As an artificial photosynthesis design, here we demonstrate the conversion of swimming green algae into photovoltaic power stations. The engineered algae exhibit bioelectrogenesis, en route to energy storage in hydrogen. Notably, fuel formation requires no additives or external bias other than CO2 and sunlight. The cellular power stations autoregulate the oxygen level during artificial photosynthesis, granting immediate utility of the photosynthetic hydrogen without separation. The fuel production scales linearly with the reactor volume, which is a necessary trait for contributing to the large-scale renewable energy portfolio.
Collapse
|
3
|
Balloon Catheter-Integrated Piezoelectric Micropyramid Arrays for Measuring Vascular Stiffness. ACS APPLIED MATERIALS & INTERFACES 2023; 15:17653-17663. [PMID: 37010291 DOI: 10.1021/acsami.3c00700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Atherosclerosis is one of the severe cardiovascular diseases in which blood vessels lose elasticity and the lumen narrows. If atherosclerosis worsens, it commonly leads to acute coronary syndrome (ACS) due to the rupture of vulnerable plaque or aortic aneurysm. As the mechanical properties of vascular tissues vary from their conditions, measuring the vascular stiffness of an inner blood vessel wall may be applied to the accurate diagnosis of atherosclerotic symptoms. Therefore, early mechanical detection of vascular stiffness is highly needed for immediate medical attention for ACS. Even with conventional examination methods such as intravascular ultrasonography and optical coherence tomography, several limitations still remain that make it difficult to directly determine the mechanical properties of the vascular tissue. As piezoelectric materials convert mechanical energy to electricity without an external power source, a piezoelectric nanocomposite could be utilized as a balloon catheter-integrated mechanical sensor on its surface. Here, we present piezoelectric nanocomposite micropyramid balloon catheter (p-MPB) arrays for measuring vascular stiffness. We study the structural characterization and feasibility of p-MPB as endovascular sensors by conducting finite element method analyses. Also, multifaceted piezoelectric voltages are measured by compression/release tests, in vitro vascular phantom tests, and ex vivo porcine heart tests to confirm that the p-MPB sensor properly operates in blood vessels.
Collapse
|
4
|
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensor. Biosens Bioelectron 2022; 220:114912. [DOI: 10.1016/j.bios.2022.114912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 10/30/2022] [Accepted: 11/10/2022] [Indexed: 11/16/2022]
|
5
|
Research progress on detachable microneedles for advanced applications. Expert Opin Drug Deliv 2022; 19:1115-1131. [PMID: 36062366 DOI: 10.1080/17425247.2022.2121388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Microneedles (MNs) have undergone great advances in transdermal drug delivery, and commercialized MN applications are currently available in vaccination and cosmetic products. Despite the development of MN technologies, common limitations of MN products still exist. Typical MN patches are applied to target tissues, where the substrate of an MN patch must remain until the drug is delivered, which reduces patients' compliance and hinders the applicability of the MN technique to many diseases in various tissues. MN research is ongoing to solve this issue. AREAS COVERED Most recent MNs developed by combining various biomaterials with appropriate fabrication processes are detachable MNs (DeMNs). Because of advances in biomaterials and fabrication techniques, various DeMNs have been rapidly developed. In this review, we discuss four types of DeMN: substrate-separable, multi-layered, crack-inducing, and shell DeMN. These DeMNs deliver various therapeutic agents ranging from small- and large-molecular-weight drugs to proteins and even stem cells for regeneration therapy. Furthermore, DeMNs are applied to skin as well as non-transdermal tissues. EXPERT OPINION It has become increasingly evident that novel MN technologies can be expected in terms of designs, fabrication methods, materials, and even possible application sites given the recent advances in DeMNs.
Collapse
|
6
|
Self‐Plugging Microneedle (SPM) for Intravitreal Drug Delivery (Adv. Healthcare Mater. 12/2022). Adv Healthc Mater 2022. [DOI: 10.1002/adhm.202270068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
7
|
Self-Plugging Microneedle (SPM) for Intravitreal Drug Delivery. Adv Healthc Mater 2022; 11:e2102599. [PMID: 35192734 DOI: 10.1002/adhm.202102599] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/09/2022] [Indexed: 01/26/2023]
Abstract
Intravitreal injection (IVI) is a common technology which is used to treat ophthalmic diseases inside eyeballs by delivering various drugs into the vitreous cavity using hypodermic needles. However, in some cases, there are possible side effects such as ocular tissue damage due to repeated injection or eyeball infection through the hole created during the needle retraction process. The best scenario of IVI is a one-time injection of drugs without needle retraction, keeping the system of the eyeball closed. Microneedles (MNs) have been applied to ocular tissues over 10 years, and no serious side effects on ocular tissue due to MN injection have been reported. Therefore, a self-plugging MN (SPM) is developed to perform intraocular drug delivery and to seal the scleral puncture simultaneously. The SPMs are fabricated by a thermal drawing process and then coated with a polymeric carrier of drugs and a hydrogel-based scleral plugging component. Each coated functional layer is characterized and demonstrated by in vitro and ex vivo experiments. Finally, in vivo tests using a porcine model confirms prompt sealing of SPM and sustained intraocular drug delivery.
Collapse
|
8
|
Photosynthetic Nanomaterial Hybrids for Bioelectricity and Renewable Energy Systems. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2005919. [PMID: 33236450 DOI: 10.1002/adma.202005919] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/08/2020] [Indexed: 06/11/2023]
Abstract
Harvesting solar energy in the form of electricity from the photosynthesis of plants, algal cells, and bacteria has been researched as the most environment-friendly renewable energy technology in the last decade. The primary challenge has been the engineering of electrochemical interfacing with photosynthetic apparatuses, organelles, or whole cells. However, with the aid of low-dimensional nanomaterials, there have been many advances, including enhanced photon absorption, increased generation of photosynthetic electrons (PEs), and more efficient transfer of PEs to electrodes. These advances have demonstrated the possibility for the technology to advance to a new level. In this article, the fundamentals of photosynthesis are introduced. How PE harvesting systems have improved concerning solar energy absorption, PE production, and PE collection by electrodes is discussed. The review focuses on how different kinds of nanomaterials are applied and function in interfacing with photosynthetic materials for enhanced PE harvesting. Finally, the review analyzes how the performance of PE harvesting and stand-alone systems have evolved so far and its future prospects.
Collapse
|
9
|
Highly flexible and porous silk fibroin microneedle wraps for perivascular drug delivery. J Control Release 2021; 340:125-135. [PMID: 34688718 DOI: 10.1016/j.jconrel.2021.10.024] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 10/17/2021] [Accepted: 10/19/2021] [Indexed: 12/29/2022]
Abstract
Various perivascular drug delivery techniques have been demonstrated for localized post-treatment of intimal hyperplasia: a vascular inflammatory response caused by endothelial damages. Although most perivascular devices have focused on controlling the delivery duration of anti-proliferation drug, the confined and unidirectional delivery of the drug to the target tissue has become increasingly important. In addition, careful attention should also be paid to the luminal stability and the adequate exchange of vascular protein or cell between the blood vessel and extravascular tissue to avoid any side effect from the long-term application of any perivascular device. Here, a highly flexible and porous silk fibroin microneedle wrap (Silk MN wrap) is proposed to directly inject antiproliferative drug to the anastomosis sites while ensuring sufficient vascular exchanges. Drug-embedded silk MNs were transfer-molded on a highly flexible and porous silk wrap. The enhanced cell compatibility, molecular permeability, and flexibility of silk MN wrap guaranteed the structural integrity of blood vessels. Silk wrap successfully supported the silk MNs and induced multiple MN penetration to the target tissue. Over 28 days, silk MN wrap significantly inhibited intimal hyperplasia with a 62.1% reduction in neointimal formation.
Collapse
|
10
|
Corneal Microneedles: Single Administration of a Biodegradable, Separable Microneedle Can Substitute for Repeated Application of Eyedrops in the Treatment of Infectious Keratitis (Adv. Healthcare Mater. 11/2021). Adv Healthc Mater 2021. [DOI: 10.1002/adhm.202170054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
11
|
Single Administration of a Biodegradable, Separable Microneedle Can Substitute for Repeated Application of Eyedrops in the Treatment of Infectious Keratitis. Adv Healthc Mater 2021; 10:e2002287. [PMID: 33930253 DOI: 10.1002/adhm.202002287] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 03/22/2021] [Indexed: 11/07/2022]
Abstract
Infectious keratitis is mainly treated with topical antibiotics. To achieve and maintain the required therapeutic concentration in the cornea where the tear fluid continuously rinses the surface, the antibiotics must be frequently applied, even while the patient is sleeping, and oral medication is sometimes required. However, the inevitably poor compliance and avascular nature of the cornea decrease drug bioavailability. In this study, a single microneedle (MN) is injected into the cornea to substitute for the repeated application of eyedrops in the treatment of infectious keratitis. After comparing the mechanical integrity and drug release profiles of three different drug-tips, the drug-tip with the "high" drug concentration that releases 12.5 ng drug within 3 days is applied to a cornea to evaluate the transferability and in vivo drug release. In the treatment of infectious keratitis with repeated application of eyedrops for six consecutive days, a single MN injection is substituted for the initial 3 days of eyedrop applications. The progression remains similarly attenuated after 3 days without eyedrops, and comparable efficacy is achieved on day 6 when combined with delayed eyedrop treatment from day 3. Thus, the single administration of a biodegradable MN can substitute for the repeated application of eyedrops in the treatment of infectious keratitis.
Collapse
|
12
|
Enhanced interfacial electron transfer between thylakoids and RuO 2 nanosheets for photosynthetic energy harvesting. SCIENCE ADVANCES 2021; 7:7/20/eabf2543. [PMID: 33980487 PMCID: PMC8115919 DOI: 10.1126/sciadv.abf2543] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 03/29/2021] [Indexed: 06/12/2023]
Abstract
The harvesting of photosynthetic electrons (PEs) directly from photosynthetic complexes has been demonstrated over the past decade. However, their limited efficiency and stability have hampered further practical development. For example, despite its importance, the interfacial electron transfer between the photosynthetic apparatus and the electrode has received little attention. In this study, we modified electrodes with RuO2 nanosheets to enhance the extraction of PEs from thylakoids, and the PE transfer was promoted by proton adsorption and surface polarity characteristics. The adsorbed protons maintained the potential of an electrode more positive, and the surface polarity enhanced thylakoid attachment to the electrode in addition to promoting ensemble docking between the redox species and the electrode. The RuO2 bioanode exhibited a five times larger current density and a four times larger power density than the Au bioanode. Last, the electric calculators were successfully powered by photosynthetic energy using a RuO2 bioanode.
Collapse
|
13
|
Optimal Voltage and Electrical Pulse Conditions for Electrical Ablation to Induce Immunogenic Cell Death (ICD). J IND ENG CHEM 2021. [DOI: 10.1016/j.jiec.2020.10.038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
14
|
Electrosprayed Thylakoid-Alginate Film on a Micro-Pillar Electrode for Scalable Photosynthetic Energy Harvesting. ACS APPLIED MATERIALS & INTERFACES 2020; 12:54683-54693. [PMID: 33226773 DOI: 10.1021/acsami.0c15993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Direct harvesting of electricity from photosynthesis is highly desired as an eco-friendly and sustainable energy harvesting technology. Photosynthetic apparatuses isolated from plants, such as thylakoid membranes (TMs), are deposited on an electrode by which photosynthetic electrons (PEs) are collected from water splitting. To enhance PE collection efficiency, it is critical to increase the electrochemical interfaces between TMs and the electrode. Considering the size of TMs to be around a few hundred nanometer, we hypothesize that an array of micropillar-shaped (MP) electrode can maximize the TM/electrode interface area. Thus, we developed MP electrodes with different heights and investigated the electrospraying of TM-alginate mixtures to fill the gaps between MPs uniformly and conformally. The uniformity of the TM-alginate film and the interaction between the TM and the MP electrode were evaluated to understand how the MP heights and film quality influenced the magnitude of the PE currents. PE currents increased up to 2.4 times for an MP electrode with an A/R of 1.8 compared to a flat electrode, indicating increased direct contact interface between TMs and the electrode. Furthermore, to demonstrate the scalability of this approach, an array of replicated SU-8 MP electrodes was prepared and PE currents of up to 3.2 μA were monitored without a mediator under 68 mW/cm2. Finally, the PE current harvesting was sustained for 14 days without decay, demonstrating the long-term stability of the TM-alginate biophotoanodes.
Collapse
|
15
|
Combination of Irreversible Electroporation and STING Agonist for Effective Cancer Immunotherapy. Cancers (Basel) 2020; 12:cancers12113123. [PMID: 33114476 PMCID: PMC7693597 DOI: 10.3390/cancers12113123] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 10/15/2020] [Accepted: 10/19/2020] [Indexed: 02/07/2023] Open
Abstract
Recently, cancer immunotherapy has received attention as a viable solution for the treatment of refractory tumors. However, it still has clinical limitations in its treatment efficacy due to inter-patient tumor heterogeneity and immunosuppressive tumor microenvironment (TME). In this study, we demonstrated the triggering of anti-cancer immune responses by a combination of irreversible electroporation (IRE) and a stimulator of interferon genes (STING) agonist. Optimal electrical conditions inducing damage-associated molecular patterns (DAMPs) by immunogenic cell death (ICD) were determined through in vitro 2D and 3D cell experiments. In the in vivo syngeneic lung cancer model, the combination of IRE and STING agonists demonstrated significant tumor growth inhibition. We believe that the combination strategy of IRE and STING agonists has potential for effective cancer immunotherapy.
Collapse
|
16
|
Photoelectric Silk via Genetic Encoding and Bioassisted Plasmonics. ADVANCED BIOSYSTEMS 2020; 4:e2000040. [PMID: 32462817 DOI: 10.1002/adbi.202000040] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/22/2020] [Indexed: 01/11/2023]
Abstract
Genetically encoded photoelectric silk that can convert photons to electrons (light to electricity) over a wide visible range in a self-power mode is reported. As silk is a versatile host material with electrical conductivity, biocompatibility, and processability, a photoelectric protein is genetically fused with silk by silkworm transgenesis. Specifically, mKate2, which is conventionally known as a far-red fluorescent protein, is used as a photoelectric protein. Characterization of the electrochemical and optical properties of mKate2 silk allows designing a photoelectric measurement system. A series of in situ photocurrent experiments support the sensitive and stable performance of photoelectric conversion. In addition, as a plasmonic nanomaterial with a broad spectral resonance, titanium nitride (TiN) nanoparticles are biologically hybridized into the silk glands, taking full advantage of the silkworms' open circulatory system as well as the absorption band of mKate2 silk. This biological hybridization via direct feeding of TiN nanoparticles further enhances the overall photoelectric conversion ability of mKate2 silk. It is envisioned that the biologically derived photoelectric protein, its ecofriendly scalable production by transgenic silkworms, and the bioassisted plasmonic hybridization can potentially broaden the biomaterial choices for developing next-generation biosensing, retina prosthesis, and neurostimulation applications.
Collapse
|
17
|
Microneedle drug eluting balloon for enhanced drug delivery to vascular tissue. J Control Release 2020; 321:174-183. [DOI: 10.1016/j.jconrel.2020.02.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 02/03/2020] [Accepted: 02/05/2020] [Indexed: 10/25/2022]
|
18
|
Non-transdermal microneedles for advanced drug delivery. Adv Drug Deliv Rev 2019; 165-166:41-59. [PMID: 31837356 PMCID: PMC7295684 DOI: 10.1016/j.addr.2019.11.010] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Revised: 11/21/2019] [Accepted: 11/25/2019] [Indexed: 12/21/2022]
Abstract
Microneedles (MNs) have been used to deliver drugs for over two decades. These platforms have been proven to increase transdermal drug delivery efficiency dramatically by penetrating restrictive tissue barriers in a minimally invasive manner. While much of the early development of MNs focused on transdermal drug delivery, this technology can be applied to a variety of other non-transdermal biomedical applications. Several variations, such as multi-layer or hollow MNs, have been developed to cater to the needs of specific applications. The heterogeneity in the design of MNs has demanded similar variety in their fabrication methods; the most common methods include micromolding and drawing lithography. Numerous materials have been explored for MN fabrication which range from biocompatible ceramics and metals to natural and synthetic biodegradable polymers. Recent advances in MN engineering have diversified MNs to include unique shapes, materials, and mechanical properties that can be tailored for organ-specific applications. In this review, we discuss the design and creation of modern MNs that aim to surpass the biological barriers of non-transdermal drug delivery in ocular, vascular, oral, and mucosal tissue.
Collapse
|
19
|
Three-Step Thermal Drawing for Rapid Prototyping of Highly Customizable Microneedles for Vascular Tissue Insertion. Pharmaceutics 2019; 11:pharmaceutics11030100. [PMID: 30813634 PMCID: PMC6470662 DOI: 10.3390/pharmaceutics11030100] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Revised: 02/20/2019] [Accepted: 02/21/2019] [Indexed: 01/24/2023] Open
Abstract
Microneedles (MNs) have been extensively developed over the last two decades, and highly efficient drug delivery was demonstrated with their minimal invasiveness via a transdermal route. Recently, MNs have not only been applied to the skin but also to other tissues such as blood vessels, scleral tissue, and corneal tissue. In addition, the objective of the MN application has been diversified, ranging from drug delivery to wound closure and biosensing. However, since most MN fabrication methods are expensive and time-consuming, they are inappropriate to prototype MNs for various tissues that have different and complex anatomies. Although several drawing-based techniques have been introduced for rapid MN production, they fabricated MNs with limited shapes, such as thin MNs with wide bases. In this study, we propose a three-step thermal drawing for rapid, prototyping MNs that can have a variety of shapes and can be fabricated on curved surfaces. Based on the temperature control of polymer bridge formation during thermal drawing, the body profile and aspect ratios of MNs were conveniently controlled, and the effect of temperature control on the body profile of MNs was explained. Thermally drawn MNs with different shapes were fabricated both on flat and curved surfaces, and they were characterized in terms of their mechanical properties and insertion into vascular tissue to find an optimal shape for vascular tissue insertion.
Collapse
|
20
|
A 0.9m Long 0.5gf Resolution Catheter-based Force Sensor for Real-Time Force Monitoring of Cardiovascular Surgery. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:3338-3341. [PMID: 30441103 DOI: 10.1109/embc.2018.8512951] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This paper presents a 0.9m long capacitive force sensor for a catheter integration, which measures a contact force to inner vessel wall or organs with a resolution of 0.5gf. The force sensor is implemented with a thin flexible printed circuit board (FPCB) encapsulated by a force sensitive medium, multilayer polydimethylsiloxane (PDMS). The parasitic capacitance $( \mathrm {C}_{P})$ inherent in long catheters significantly degrades the sensing accuracy of capacitive force sensors. To account for this, this work proposes a sensor interface with $\mathrm {C}_{P}$ canceller. By removing the 348pF (91.5%) of $\mathrm {C}_{\mathrm{P}}$with the $\mathrm {C}_{\mathrm{P}}$ canceller, the capacitive force sensor achieves a capacitance resolution of 16aF equivalent to a force error of 0.5gf, which is a $10 \times $ improvement compared to the conventional sensor interface. The proposed force sensor offers great potential for real-time force monitoring of cardiovascular surgery.
Collapse
|
21
|
Intracorneal injection of a detachable hybrid microneedle for sustained drug delivery. Acta Biomater 2018; 80:48-57. [PMID: 30267886 DOI: 10.1016/j.actbio.2018.09.039] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Revised: 09/10/2018] [Accepted: 09/24/2018] [Indexed: 12/31/2022]
Abstract
There are increasing demands for long-term and controlled corneal drug delivery to treat various ocular diseases. Although biodegradable ocular inserts or contact lenses have been developed, the invasiveness and inefficiency of the approaches still need to be improved. Microneedle (MN) technology can deliver therapeutic molecules to the eye in a minimally invasive manner. However, the current ocular MN technology is limited to either short-term corneal drug delivery or retinal drug delivery by suprachoroidal injection. For long-term and minimally invasive corneal drug delivery, we have developed a detachable biodegradable MN that can be delivered to the inside of the cornea for sustained drug release. The detachable and biodegradable MN is a hybrid MN consisting of a drug-loaded biodegradable tip and a supporting base. The hybrid MN can be applied to the cornea by impact insertion, and it leaves only the drug-loaded biodegradable tip within the corneal tissue so that it can release the drug for a certain period. By concentration-controlled molding, the dimension of drug-loaded MN tips was precisely controlled and their detachability was optimized. The detachable tip and a supporting base were assembled to form a hybrid MN by pressure-assisted transfer molding. We carefully optimized the dimension of the drug-tip, injection dwell time, and insertion depth to achieve effective intracorneal injection of the drug-tip. The detachable hybrid MN was applied to an Acanthamoeba keratitis model wherein a biodegradable drug-tip was successfully delivered to the inside of the mouse cornea in vivo. Follow-up of the MN-treated cases for 7 days confirmed the therapeutic efficacy of the detachable biodegradable MN tips. STATEMENT OF SIGNIFICANCE: For the treatment of infectious diseases in the cornea, such as keratitis, eye drops need to be applied topically every hour for a couple of days. This is extremely uncomfortable, and poor compliance to such tightly scheduled drug administration can result in permanent scar formation in the cornea. In this work, we demonstrate a simple and rapid injection of biodegradable microneedle tips in the corneal tissue wherein the tips can deliver antibacterial drugs for 4 days to treat keratitis. Unlike other patch-style microneedle technologies, this approach allows for insertion depth-controlled and highly localized injection of detachable individual microneedle tips to the diseased tissue for sustained drug delivery. This overcomes the limitations of patch-style microneedles such as short-term drug delivery and unnecessary blockage of tissue.
Collapse
|
22
|
A Parasitic Insensitive Catheter-Based Capacitive Force Sensor for Cardiovascular Diagnosis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:812-823. [PMID: 29994663 DOI: 10.1109/tbcas.2018.2832172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This paper presents a catheter-based capacitive force sensor interface for cardiovascular diagnosis. The force sensor is implemented on a flexible printed circuit board (FPCB) substrate with a force-sensitive polydimethylsiloxane (PDMS), and a force-induced change in a capacitance of the sensor is measured by a precision capacitive sensor interface. To recover the performance degradation caused by the large parasitic capacitance ${\rm C}_{\rm P}$ of a long catheter, we present a parasitic insensitive analog front-end (AFE) with active ${\rm C}_{\rm P}$ cancellation, which employs a charge amplifier and a negative capacitor at the virtual ground of the charge amplifier. The prototype sensor was measured with a force loader in whole blood. The proposed AFE successfully cancels ${\rm C}_{\rm P}$ of 348 pF in a 0.9-m-long sensor and measurement results show the SNR of 53.8 dB and the capacitance resolution of 16 aF, a 19.6 dB improvement by canceling nonideal effect of ${\rm C}_{\rm P}$ . This corresponds to a force resolution of 2.22 gf, which is 9.29 $\times$ reduction compared to the work without the ${\rm C}_{\rm P}$ cancellation. The proposed sensor interface is insensitive to ${\rm C}_{\rm P}$ from hundreds to 1-nF level, and the force-dependent stiffness of two different tissues has been successfully distinguished with an ex-vivo experiment. The proposed sensor interface enables the integration of capacitive force sensors in a smart catheter.
Collapse
|
23
|
Electrospun Silk Fibroin Nanofibrous Scaffolds with Two-Stage Hydroxyapatite Functionalization for Enhancing the Osteogenic Differentiation of Human Adipose-Derived Mesenchymal Stem Cells. ACS APPLIED MATERIALS & INTERFACES 2018; 10:7614-7625. [PMID: 28475306 DOI: 10.1021/acsami.7b03328] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The development of functional scaffolds with improved osteogenic potential is important for successful bone formation and mineralization in bone tissue engineering. In this study, we developed a functional electrospun silk fibroin (SF) nanofibrous scaffold functionalized with two-stage hydroxyapatite (HAp) particles, using mussel adhesive-inspired polydopamine (PDA) chemistry. HAp particles were first incorporated into SF scaffolds during the electrospinning process, and then immobilized onto the electrospun SF nanofibrous scaffolds containing HAp via PDA-mediated adhesive chemistry. We obtained two-stage HAp-functionalized SF nanofibrous scaffolds with improved mechanical properties and capable of providing a bone-specific physiological microenvironment. The developed scaffolds were tested for their ability to enhance the osteogenic differentiation of human adipose-derived mesenchymal stem cells (hADMSCs) in vitro and repair bone defect in vivo. To boost their ability for bone repair, we genetically modified hADMSCs with the transcriptional coactivator with PDZ-binding motif (TAZ) via polymer nanoparticle-mediated gene delivery. TAZ is a well-known transcriptional modulator that activates the osteogenic differentiation of mesenchymal stem cells (MSCs). Two-stage HAp-functionalized SF scaffolds significantly promoted the osteogenic differentiation of TAZ-transfected hADMSCs in vitro and enhanced mineralized bone formation in a critical-sized calvarial bone defect model. Our study shows the potential utility of SF scaffolds with nanofibrous structures and enriched inorganic components in bone tissue engineering.
Collapse
|
24
|
Microchannel system for rate-controlled, sequential, and pH-responsive drug delivery. Acta Biomater 2018; 68:249-260. [PMID: 29269333 DOI: 10.1016/j.actbio.2017.12.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 11/22/2017] [Accepted: 12/11/2017] [Indexed: 01/06/2023]
Abstract
Controlled delivery of drug at a constant rate, in a sequential order, or responsive to environment conditions has been pursued for a long time to enhance the efficacy of therapeutic molecules and to minimize side effects of highly potent drugs. However, achieving such delicately-controlled delivery of a drug molecule is non-trivial and still remains a challenge. We propose the use of microchannels to control the rate, sequence, and pH-responsiveness of drug delivery for high precision and predictability. In this study, we introduce elementary drug delivery units consisting of micro-reservoirs and microchannels that have variations in their lengths, widths, numbers, and straightness. The release study demonstrates that the release rates of model drugs can be modulated by the design of microchannels. Finite element modeling of drug release predicts the performance of the drug delivery units with high accuracy. The possibility of sequential drug delivery is also demonstrated using biodegradable polymer plug in microchannels. Finally, pH-responsive delivery of drugs in microfluidic units is also discussed and demonstrated via cell viability tests. STATEMENT OF SIGNIFICANCE In this work, we developed microchannel-based drug delivery devices whose release rate could be accurately calculated and controlled by design of microchannel geometry. Although there have been many advances in microfabricated drug delivery systems, in particular, reservoir-based systems, no systematic investigation has been made to utilize the release channels. In our work, an equivalent electrical circuit concept was applied to the microfluidic systems for more detailed design and analysis. A microfluidic channel was regarded as an electrical resistor; their diffusion/electrical flux could be tuned with geometric factors such as length, width, a number of channel/resistor and their connections. Furthermore, from delivery rate control using channel geometry, multifunctional channel-based release systems for sequential and pH-responsive were demonstrated.
Collapse
|
25
|
|
26
|
Transfer-molded wrappable microneedle meshes for perivascular drug delivery. J Control Release 2017; 268:237-246. [PMID: 29030224 DOI: 10.1016/j.jconrel.2017.10.007] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 09/11/2017] [Accepted: 10/06/2017] [Indexed: 12/27/2022]
Abstract
After surgical procedures such as coronary/peripheral bypass grafting or endarterectomy for the treatment of organ ischemia derived from atherosclerosis, intimal hyperplasia (IH) which leads to restenosis or occlusion at the site of graft anastomosis frequently occurs. In order to inhibit IH caused by abnormal growth of smooth muscle cells (SMCs) in tunica media, various perivascular drug delivery devices are reported for delivery of anti-proliferation drugs into vascular tissue. However, there still remain conflicting requirements such as local and unidirectional delivery vs device porosity, and conformal tight device installation vs pulsatile expansion and constriction of blood vessels. In this study, a biodegradable microneedle (MN) array is developed on a flexible woven surgical mesh using a transfer molding method. Mechanical properties of 'wrappable' MN meshes are investigated and compared to the properties of blood vessels. Ex vivo and in vivo animal studies demonstrate enhanced drug delivery efficiency, efficacy for IH reduction, and safety of MN mesh. In particular, MN mesh showed significantly reduced neointiamal formation (11.1%) compared to other competitive groups (23.7 and 22.2%) after 4-week in vivo animal study. Additionally, wrappable MN meshes effectively suppressed side effects such as IH due to mechanical constriction, loss of toxic drug to the surroundings, and cell death that were frequently observed with other previous perivascular drug delivery devices.
Collapse
|
27
|
Random lasing from structurally-modulated silk fibroin nanofibers. Sci Rep 2017; 7:4506. [PMID: 28674433 PMCID: PMC5495807 DOI: 10.1038/s41598-017-04881-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 05/22/2017] [Indexed: 02/01/2023] Open
Abstract
Structural arrangement and dimension play vital roles in wave transport and amplification as they can restrict the volume explored by the waves. However, it is challenging to systematically investigate the interplay among structural, optical, and mechanical properties, in part because of limited experimental platforms that modulate the structural arrangement in a continuous manner. We present light amplification action in Rhodamine B doped silk fibroin (SF) nanofibrous scaffolds and its modulation via the control of the alignment or directionality of SF nanofibers through an electrospinning procedure. Random lasing features of such scaffolds are examined as a function of structural arrangement of the SF nanofibers, and optical-structural-mechanical relationships of the SF-based structures are examined. As SF nanofibers are aligned parallel undergoing a transition from three to quasi-two dimension, light amplification features (e.g., lasing threshold and output power) enhanced, which also strongly correlated with mechanical characteristics (i.e., Young’s moduli) of the scaffolds. We confirm such optical characteristics using quasi-mode analyses based on the finite element method. We further demonstrate non-contact, in situ measurement of alternations in lasing features of the scaffolds while the specimens are under tensile loads. These results may highlight potential utility of the scaffolds as a flexible and biocompatible sensor.
Collapse
|
28
|
Microneedle-based minimally-invasive measurement of puncture resistance and fracture toughness of sclera. Acta Biomater 2016; 44:286-94. [PMID: 27521493 DOI: 10.1016/j.actbio.2016.08.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 07/27/2016] [Accepted: 08/09/2016] [Indexed: 11/16/2022]
Abstract
UNLABELLED The sclera provides the structural support of the eye and protects the intraocular contents. Since it covers a large portion of the eye surface and has relatively high permeability for most drugs, the sclera has been used as a major pathway for drug administration. Recently, microneedle (MN) technology has shown the possibility of highly local and minimally-invasive drug delivery to the eye by MN insertion through the sclera or the suprachoroidal space. Although ocular MN needs to be inserted through the sclera, there has been no systematic study to understand the mechanical properties of the sclera, which are important to design ocular MNs. In this study, we investigated a MN-based method to measure the puncture resistance and fracture toughness of the sclera. To reflect the conditions of MN insertion into the sclera, force-displacement curves obtained from MN-insertion tests were used to estimate the puncture resistance and fracture toughness of sclera tissue. To understand the effect of the insertion conditions, dependency of the mechanical properties on insertion speeds, pre-strain of the sclera, and MN sizes were analyzed and discussed. STATEMENT OF SIGNIFICANCE Measurement of mechanical property of soft biological tissue is challenging due to variations between tissue samples or lack of well-defined measurement techniques. Although non-invasive measurement techniques such as nano/micro indentation were employed to locally measure the elastic modulus of soft biological materials, mechanical properties such as puncture resistance or fracture toughness, which requires "invasive" measurement and is important for the application of "microneedles or hypodermic needles", has not been well studied. In this work, we report minimally-invasive measurement of puncture resistance and fracture toughness of sclera using a double MN insertion method. Parametric studies showed that use of MN proved to be advantageous because of minimally-invasive insertion into tissue as well as higher sensitivity to sub-tissue architecture during the measurement.
Collapse
|
29
|
A novel low-profile thin-film nitinol/silk endograft for treating small vascular diseases. J Biomed Mater Res B Appl Biomater 2015; 105:575-584. [PMID: 26663772 DOI: 10.1002/jbm.b.33548] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2015] [Revised: 09/20/2015] [Accepted: 09/27/2015] [Indexed: 11/08/2022]
Abstract
Since the introduction of various endovascular graft materials such as expanded polytetrafluoroethylene (e-PTFE) and Dacron® polyester, they have been rapidly applied in endovascular devices for treating a variety of clinical situations. While present endovascular grafts have been successful in treating large blood vessels, there are still significant challenges and limitations for small and tortuous vessels to their use. Recently, our group has demonstrated the potential to use thin-film nitinol (TFN) as a novel material to develop endografts used in the treatment of a wide range of small vascular diseases because TFN is ultralow profile (that is, a few micrometers thick), relatively thromboresistant, and superelastic. While TFN has shown superior thromboresistance, its surface endothelialization is not rapid and sufficient. Therefore, our laboratory has been exploring the feasibility of using thin-film silk as a novel coating for facilitating rapid and confluent endothelial cell growth. The purpose of this study is to fabricate a low-profile composite endograft using thin layers of nitinol and silk, and to evaluate both thrombogenicity as well as endothelial cell and smooth muscle cell responses. This study also evaluates the functionality of the composite endograft using an in vitro blood circulation model. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 575-584, 2017.
Collapse
|
30
|
Three-Dimensional Rapid Prototyping of Multidirectional Polymer Nanoprobes for Single Cell Insertion. ACS APPLIED MATERIALS & INTERFACES 2015; 7:16873-16880. [PMID: 26144221 DOI: 10.1021/acsami.5b05254] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Three-dimensional (3D) thermal drawing at nanoscale as a novel rapid prototyping method was demonstrated to create multidirectional polymer nanoprobes for single cell analysis. This 3D drawing enables simple and rapid fabrication of polymeric nanostructures with high aspect ratio. The effect of thermal drawing parameters, such as drawing speeds, dipping depths, and contact duration on the final geometry of polymer nanostructures was investigated. Vertically aligned and L-shaped nanoprobes were fabricated and their insertion into living single cells such as algal cells and human neural stem cells was demonstrated. This technique can be extended to create more complex 3D structures by controlling drawing steps and directions on any surface.
Collapse
|
31
|
Rapid and repeatable fabrication of high A/R silk fibroin microneedles using thermally-drawn micromolds. Eur J Pharm Biopharm 2015; 94:11-9. [DOI: 10.1016/j.ejpb.2015.04.024] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2014] [Revised: 04/19/2015] [Accepted: 04/20/2015] [Indexed: 11/26/2022]
|
32
|
Impact insertion of transfer-molded microneedle for localized and minimally invasive ocular drug delivery. J Control Release 2015; 209:272-9. [DOI: 10.1016/j.jconrel.2015.04.041] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2014] [Revised: 03/26/2015] [Accepted: 04/28/2015] [Indexed: 10/23/2022]
|
33
|
Membrane-reinforced three-dimensional electrospun silk fibroin scaffolds for bone tissue engineering. Biomed Mater 2015; 10:035011. [DOI: 10.1088/1748-6041/10/3/035011] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
34
|
Biodegradation-tunable mesoporous silica nanorods for controlled drug delivery. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 50:64-73. [DOI: 10.1016/j.msec.2015.01.073] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 12/26/2014] [Accepted: 01/23/2015] [Indexed: 10/24/2022]
|
35
|
Perivascular biodegradable microneedle cuff for reduction of neointima formation after vascular injury. J Control Release 2014; 192:174-81. [PMID: 25025286 DOI: 10.1016/j.jconrel.2014.07.007] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2014] [Revised: 06/30/2014] [Accepted: 07/06/2014] [Indexed: 11/28/2022]
Abstract
Restenosis often occurs at the site of vascular grafting and may become fatal for patients. Restenosis at anastomosis sites is due to neointimal hyperplasia (NH) and difficult to treat with conventional treatments. Such abnormal growth of smooth muscle cells in tunica media of vascular tissue can be reduced by delivering anti-proliferation drugs such as paclitaxel (PTX) to the inner vascular layer. Drug eluting stents (DES) or drug eluting balloon (DEB) have been developed to treat such vascular diseases. However, they are less efficient in drug delivery due to the drug loss to blood stream and inadequate to be applied to re-stenotic area in the presence of stent or anastomosis sites. Recently, we have introduced microneedle cuff (MNC) as perivascular delivery devices to achieve high delivery efficiency to tunica media. In this study, we investigated in vivo microneedle insertion and efficacy in treating NH using a rabbit balloon injury model. Microneedle shape was optimized for reliable insertion into tunica media layer. Uniform distribution of PTX in tunica media delivered by MNC devices was also confirmed. Animal study demonstrated significant NH reduction by MNC treatments and much higher delivery efficiency than flat type devices.
Collapse
|
36
|
Abstract
Wet tapping of nanoparticles for precisely-patterned nanoprobe arrays was developed to fabricate cell insertion tools for parallel multiple cell probing.
Collapse
|
37
|
Nanoprobe arrays for multiple single cell insertion using heterogeneous nanosphere lithography (HNSL). NANOSCALE 2013; 5:7809-7813. [PMID: 23868390 DOI: 10.1039/c3nr01890c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Nanoprobe arrays for multiple single cell insertion were developed using heterogeneous nanosphere lithography. Using two heterogeneous nanoparticles as sacrificial and masking particles, high aspect ratio Si nanoprobes were fabricated in an array with spacing between the nanoprobes ranging from a few to tens of micrometers. For registered single cell analysis, multiple and precise insertion of nanoprobes into multiple single cells in a parallel fashion was demonstrated using micropipette suction and micromanipulators.
Collapse
|
38
|
Abstract
When micro-reservoir-type drug delivery systems are fabricated, loading solid drugs in drug reservoirs at microscale is often a non-trivial task. This paper presents a simple and effective solution to load a small amount of drug solution at microscale using 'wet' microcontact printing (µCP). In this wet µCP, a liquid solution containing drug molecules (methylene blue and tetracycline HCl) dissolved in a carrier solvent was transferred to a target surface (drug reservoir) by contact printing process. In particular, we have investigated the dependence of the quantity and morphology of transferred drug molecules on the stamp size, concentration, printing times, solvent types and surfactant concentration. It was also found that the repetition of printing using a non-volatile solvent such as polyethylene glycol (PEG) as a drug carrier material actually increased the transferred amount of drug molecules in proportion to the printing times based on asymmetric liquid bridge formation. Utilizing this wet µCP, drug delivery devices containing different quantity of drugs in micro-reservoirs were fabricated and their performance as controlled drug delivery devices was demonstrated.
Collapse
|
39
|
Spatially discrete thermal drawing of biodegradable microneedles for vascular drug delivery. Eur J Pharm Biopharm 2013. [DOI: 10.1016/j.ejpb.2012.10.020] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
40
|
Controlled release of bupivacaine HCl through microchannels of biodegradable drug delivery device. Biomed Microdevices 2012; 14:583-93. [PMID: 22374474 DOI: 10.1007/s10544-012-9637-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Local and prolonged delivery of local analgesics is much desired for post-operative pain management. For delivery of local analgesics at a constant rate over couple of days, a microfluidic device comprised of a drug reservoir and microchannels for drug release was developed using a biodegradable polymer, 85/15 poly(lactic-co-glycolic acid). Unlike conventional methods relying on material property, this device enables convenient modulation of the release speed of drugs by a simple change of the channel geometry such as the length and cross-sectional area. Bupivacaine was selected as our model local analgesic drug and its diffusional transport through microchannels was studied using the microfluidic devices. However, since the salt form of bupivacaine, bupivacaine hydrochloride, has pH-dependent solubility, its precipitation in microchannels had an adverse impact on the release performance of the microfluidic drug delivery devices. Thus, in this investigation, the diffusional transport and precipitation of bupivacaine hydrochloride in microfluidic channels were studied using in vitro release experiments and optical analysis. Furthermore, a concept of co-delivery of bupivacaine hydrochloride together with acidic additives was demonstrated to achieve a zero-order delivery of bupivacaine hydrochloride without the clogging of microchannels by its precipitation.
Collapse
|
41
|
Direct extraction of photosynthetic electrons from single algal cells by nanoprobing system. NANO LETTERS 2010; 10:1137-1143. [PMID: 20201533 DOI: 10.1021/nl903141j] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
There are numerous sources of bioenergy that are generated by photosynthetic processes, for example, lipids, alcohols, hydrogen, and polysaccharides. However, generally only a small fraction of solar energy absorbed by photosynthetic organisms is converted to a form of energy that can be readily exploited. To more efficiently use the solar energy harvested by photosynthetic organisms, we evaluated the feasibility of generating bioelectricity by directly extracting electrons from the photosynthetic electron transport chain before they are used to fix CO(2) into sugars and polysaccharides. From a living algal cell, Chlamydomonas reinhardtii, photosynthetic electrons (1.2 pA at 6000 mA/m(2)) were directly extracted without a mediator electron carrier by inserting a nanoelectrode into the algal chloroplast and applying an overvoltage. This result may represent an initial step in generating "high efficiency" bioelectricity by directly harvesting high energy photosynthetic electrons.
Collapse
|
42
|
Lympho-Vascular Invasion by Detecting D2-40 Was the Potent Prognostic Predictor in Breast Cancer Patients. Cancer Res 2009. [DOI: 10.1158/0008-5472.sabcs-09-6171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
(Introduction) Distant metastasis and recurrence are the major factors of prognosis in breast cancer patients. Both of lymphovascular invasion (LVI) and blood vascular invasion (BVI) are known to be the important route for metastasis to regional lymph nodes and systemic metastasis. Despite the importance of vascular invasion as a prognostic factor, the application of vascular invasion as a histopathologic criterion is controversial. The aims of this study were to distinguish between LVI and BVI for the role of prognosis and recurrence in breast cancer patients by using an endothelial subtype specific immunohitochemical stain (podoplanin, D2-40 and CD31)Methods) Sections from 80 paraffin-embedded archival specimens of invasive breast cancer were stained for expression of podoplanin, D2-40, and CD31. The results of immunohistochemical staining were correlated with clinicopathologic features, such as tumor size, the status of lymph node metastases, estrogen receptor status, progesterone receptor status and HER2 expression, and recurrence. The patients with ductal carcinoma in situ and stage 4 breast cancer were excluded.Results) A significant correlation was found in the higher expression of D2-40, and lymph node metastasis. (P=0.02) We found a significant correlation between the expression of D2-40 and the recurrence of breast cancer. (P=0.04) However, there was no significant correlation between BVI and recurrence. A poorer disease free survival was shown in the higher expression of D2-40. (P<0.01) In multivariate analysis, the higher expression of D2-40 revealed a significant association with decreased disease-free survival.Conclusion) The higher expression of D2-40 was the more prognostic predictor than blood vascular invasion in breast cancer patients.
Citation Information: Cancer Res 2009;69(24 Suppl):Abstract nr 6171.
Collapse
|
43
|
Infiltration of intratumoral T cells and regulatory T cells are associated with p53 expression and ER status in early breast cancer: a Korean breast cancer study. Cancer Res 2009. [DOI: 10.1158/0008-5472.sabcs-5049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Abstract #5049
Background: Immune responses, such as rich lymphocyte infiltrate, have shown associated with improved clinical outcomes in patients with breast cancer. Recently, number of tumor-infiltrating regulatory T cell has been identified as a poor prognostic marker. There is, however, not enough data evaluating the associations between the clinicopathologic factors and quantity or quality of TILs in Asian breast cancer patients.
 Material and methods: CD4-, CD8-, and Foxp3-positive tumor-infiltrating lymphocytes (TILs) were detected by immunohistochemistry using the paraffin-embedded samples from the 40 patients with early stage (I-III) breast cancer. Expression status of ER, PR, HER-2, p53, and Ki-67 were also evaluated by immunohistochemistry. Clinical data, such as pathologic stage, patient's age, were available for statistical analysis.
 Results: Statistically significant correlation between ER expression and CD8/CD4 ratio of the TILs (Spearman r=0.447, p=0.024) was observed. Other clinicopathlogical factors, such as PR, tumor size, nodal metastasis, tumor grade, did not show significant correlation with ratio of the TILs. Additionally, tumors with more dense accumulation of p53 protein were associated with recruitment of higher number of Foxp3-positive regulatory T cells (Spearman r=0.52, p=0.0002). Ki-67, a proliferation index of the tumor cells, was also statistically significantly associated with infiltration of regulatory T cells (Spearman r=0.46, p=0.019).
 Discussion: Our data showed that ER-positive tumors had higher ratio of CD8/CD4 TILs, which is opposite result from the previous studies. In addition, p53 overexpression and high proliferation index of the breast cancer were associated with high regulatory T cell infiltration, but not with total TIL. The role of the p53 overexpression of the tumor cells in determining immune balance and its prognostic implication will be evaluated in the future study.
Citation Information: Cancer Res 2009;69(2 Suppl):Abstract nr 5049.
Collapse
|
44
|
Controlled release of growth factors on allograft bone in vitro. Clin Orthop Relat Res 2008; 466:1905-11. [PMID: 18509711 PMCID: PMC2584275 DOI: 10.1007/s11999-008-0290-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2007] [Accepted: 04/23/2008] [Indexed: 01/31/2023]
Abstract
Allografts are important alternatives to autografts for treating defects after major bone loss. Bone growth factors have both local autocrine and paracrine effects and regulate the growth, proliferation, and differentiation of osteoprogenitor cells. To study the effects of prolonged, continuous, local delivery of growth factors on bone growth, we developed a new microelectromechanical system (MEMS) drug delivery device. Bone marrow cells from mice were seeded on mouse allograft discs and cultured in osteogenic media with osteogenic protein 1 (OP-1) and/or basic fibroblast growth factor (FGF-2) delivered from MEMS devices for 6 weeks. We monitored bone formation by changes of bone volume using micro-CT scanning and release of osteocalcin using ELISA. The data suggest the MEMS devices delivered constant concentrations of OP-1 and FGF-2 to the media. Bone marrow cells grew on the allografts and increased bone volume. Addition of OP-1 increased bone formation whereas FGF-2 decreased bone formation. Local delivery of growth factors over a prolonged period modulated the differentiation of osteoprogenitor cells on allograft bone.
Collapse
|
45
|
|
46
|
LONGITUDINAL FOLLOW-UP STUDY FOR CHANGES IN LIPIDS AND LIPOPROTEINS DURING THE PERIMENOPAUSE. ATHEROSCLEROSIS SUPP 2008. [DOI: 10.1016/s1567-5688(08)70390-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
47
|
Biodegradable micro-osmotic pump for long-term and controlled release of basic fibroblast growth factor. J Control Release 2007; 124:98-105. [PMID: 17904240 DOI: 10.1016/j.jconrel.2007.08.024] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2007] [Revised: 08/15/2007] [Accepted: 08/17/2007] [Indexed: 10/22/2022]
Abstract
Microelectromechanical system (MEMS) technology not only provides the possibility of integration of multiple functions but also enables more precise control of dosing of therapeutic agents when the therapeutic window is very limited. Local delivery of basic fibroblast growth factor (bFGF) over a specific dose and time course is critical for mesenchymal tissue regeneration. However, bFGF is degraded quickly in vivo and difficulty of controlling the dose level impedes its effective use in angiogenesis and tissue regeneration. We constructed biodegradable micro-osmotic pumps based on MEMS technology for long-term controlled release of bFGF. The devices were constructed by micro-molding and thermal assembly of 85/15 poly(L-lactide-co-glycolide) sheets. The release of bFGF was regulated at 40 ng/day for four weeks; bioactivity was assessed by monitoring the growth of 3T3 fibroblasts. The proposed devices can be further miniaturized and used for the delivery of multiple therapeutic agents at the individual releasing schedules.
Collapse
|
48
|
The construction of three-dimensional micro-fluidic scaffolds of biodegradable polymers by solvent vapor based bonding of micro-molded layers. Biomaterials 2007; 28:1174-84. [PMID: 17126395 DOI: 10.1016/j.biomaterials.2006.11.002] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2006] [Accepted: 11/02/2006] [Indexed: 11/28/2022]
Abstract
It is increasingly important to control cell growth into and within artificial scaffolds. Tissues such as skin, blood vessels, and cartilage have multi-layer structures with different cells in each layer. With the aid of micro-fabrication technology, a novel scaffolding method for biodegradable polymers such as polylactic acid (PLA), polyglycolic acid (PGA), and the copolymers poly(lactide-co-glycolide)(PLGA), was developed to construct three-dimensional multi-layer micro-fluidic tissue scaffolds. The method emphasizes micro-fluidic interconnections between layers within the scaffolds and maintenance of high-resolution geometries during the bonding process for the creation of multi-layered scaffolds. Micro-holes (10-100 microm), micro-channels, and micro-cavities were all created by micro-molding. Solvent-vapor based bonding of micro-molded layers preserved 20 microm sized structures. Sample scaffolds were constructed for purposes such as channel-directed cell growth and size-based cell sorting. Further extension of these techniques to create a micro-vascular network within or between layers is possible. Culturing of human coronary artery endothelial cells (HCAECs) on the sample scaffolds demonstrated the biocompatibility of the developed process and the strong influence of high-resolution micro-geometries on HCAEC growth.
Collapse
|
49
|
Effects of mixing on fed-batch fermentation of L-ornithine. J Biosci Bioeng 2005; 89:539-44. [PMID: 16232794 DOI: 10.1016/s1389-1723(00)80053-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/1999] [Accepted: 02/28/2000] [Indexed: 11/17/2022]
Abstract
The effects of mixing on L-ornithine fermentation were studied using an L-arginine auxotrophic mutant of Brevibacterium ketoglutamicum ATCC 21092. Three different modes of fed-batch culture using two different impeller types were studied in a 7 l fermentor. The first two modes of fed-batch culture were carried out in a fermentor equipped with six-flat-blade disk-turbine impellers with top and bottom feeding. The third mode of fed batch culture was carried out using pitched-six-flat-blade disk-turbine impellers with top feeding. The titre of L-ornithine increased up to 1.8 fold with bottom-feeding or when the pitched-six-flat-blade disk-turbine impellers were used compared to when the six-flat-blade disk-turbine impellers with top-feeding were used. It was observed that the mixing time of the limiting nutrients varied significantly depending on both the direction of feeding and the impeller type. Since the profiles of the specific rates of CO2 evolution, oxygen and glucose uptakes were very similar for the three culture modes, it could be reasonably assumed that the microorganism exhibited similar growth rates for each mode used. However, different amino acid producing activities were observed in the three culture modes. From these results it is concluded that the productivity of L-ornithine fermentation is significantly improved by shortening the mixing time of the limiting nutrient in the fermentor.
Collapse
|
50
|
3P-0802 Effect of fibrate on lipoprotein (a) level in hypertriglyceridemic patients. ATHEROSCLEROSIS SUPP 2003. [DOI: 10.1016/s1567-5688(03)91020-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|