1
|
Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements. Anal Chim Acta 2024; 1305:342587. [PMID: 38677841 DOI: 10.1016/j.aca.2024.342587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 03/07/2024] [Accepted: 04/07/2024] [Indexed: 04/29/2024]
Abstract
Tetrahedral DNA nanostructure (TDN) is highly promising in developing electrochemical aptamer-based (E-AB) sensors for biomolecular detection, owing to its inherit programmability, spatial orientation and structural robustness. However, current interrogation strategies applied for TDN-based E-AB sensors, including enzyme-based amperometry, voltammetry, and electrochemical impedance spectroscopy, either require complicated probe design or suffer from limited applicability or selectivity. In this study, a TDN pendulum-empowered E-AB sensor interrogated by chronoamperometry for reagent-free and continuous monitoring of a blood clotting enzyme, thrombin, was developed. TDN pendulums with extended aptamer sequences at three vertices were immobilized on a gold electrode via a thiolated double-stranded DNA (dsDNA) at the fourth vertex, and their motion is modulated by the bonding of target thrombin to aptamers. We observed a significantly amplified signalling output on our sensor based on the TDN pendulum compared to E-AB sensors modified with linear pendulums. Moreover, our sensor achieved highly selective and rapidly responsive measurement of thrombin in both PBS and artificial urine, with a wide dynamic range from 1 pM to 10 nM. This study shows chronoamperometry-enabled continuous biomarker monitoring on a sub-second timescale with a drift-free baseline, demonstrating a novel approach to accurately detect molecular dynamics in real time.
Collapse
|
2
|
Enhanced CRISPR/Cas12a-based quantitative detection of nucleic acids using double emulsion droplets. Biosens Bioelectron 2024; 257:116339. [PMID: 38688231 DOI: 10.1016/j.bios.2024.116339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 04/05/2024] [Accepted: 04/24/2024] [Indexed: 05/02/2024]
Abstract
Pairing droplet microfluidics and CRISPR/Cas12a techniques creates a powerful solution for the detection and quantification of nucleic acids at the single-molecule level, due to its specificity, sensitivity, and simplicity. However, traditional water-in-oil (W/O) single emulsion (SE) droplets often present stability issues, affecting the accuracy and reproducibility of assay results. As an alternative, water-in-oil-in-water (W/O/W) double emulsion (DE) droplets offer superior stability and uniformity for droplet digital assays. Moreover, unlike SE droplets, DE droplets are compatible with commercially available flow cytometry instruments for high-throughput analysis. Despite these advantages, no study has demonstrated the use of DE droplets for CRISPR-based nucleic acid detection. In our study, we conducted a comparative analysis to assess the performance of SE and DE droplets in quantitative detection of human papillomavirus type 18 (HPV18) DNA based on CRISPR/Cas12a. We evaluated the stability of SEs and DEs by examining size variation, merging extent, and content interaction before and after incubation at different temperatures and time points. By integrating DE droplets with flow cytometry, we achieved high-throughput and high-accuracy CRISPR/Cas12a-based quantification of target HPV18 DNA. The DE platform, when paired with CRISPR/Cas12a and flow cytometry techniques, emerges as a reliable tool for absolute quantification of nucleic acid biomarkers.
Collapse
|
3
|
Passive microfluidic devices for cell separation. Biotechnol Adv 2024; 71:108317. [PMID: 38220118 DOI: 10.1016/j.biotechadv.2024.108317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/27/2023] [Accepted: 01/06/2024] [Indexed: 01/16/2024]
Abstract
The separation of specific cell populations is instrumental in gaining insights into cellular processes, elucidating disease mechanisms, and advancing applications in tissue engineering, regenerative medicine, diagnostics, and cell therapies. Microfluidic methods for cell separation have propelled the field forward, benefitting from miniaturization, advanced fabrication technologies, a profound understanding of fluid dynamics governing particle separation mechanisms, and a surge in interdisciplinary investigations focused on diverse applications. Cell separation methodologies can be categorized according to their underlying separation mechanisms. Passive microfluidic separation systems rely on channel structures and fluidic rheology, obviating the necessity for external force fields to facilitate label-free cell separation. These passive approaches offer a compelling combination of cost-effectiveness and scalability when compared to active methods that depend on external fields to manipulate cells. This review delves into the extensive utilization of passive microfluidic techniques for cell separation, encompassing various strategies such as filtration, sedimentation, adhesion-based techniques, pinched flow fractionation (PFF), deterministic lateral displacement (DLD), inertial microfluidics, hydrophoresis, viscoelastic microfluidics, and hybrid microfluidics. Besides, the review provides an in-depth discussion concerning cell types, separation markers, and the commercialization of these technologies. Subsequently, it outlines the current challenges faced in the field and presents a forward-looking perspective on potential future developments. This work hopes to aid in facilitating the dissemination of knowledge in cell separation, guiding future research, and informing practical applications across diverse scientific disciplines.
Collapse
|
4
|
Guided axon outgrowth of neurons by molecular gradients generated from femtosecond laser-fabricated micro-holes. Talanta 2024; 267:125200. [PMID: 37738745 DOI: 10.1016/j.talanta.2023.125200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 09/04/2023] [Accepted: 09/11/2023] [Indexed: 09/24/2023]
Abstract
OBJECTIVE Transplantation of scaffold-embedded guided neurons has been reported to increase neuronal regeneration following brain injury. However, precise axonal integration between host and transplant neurons to form functional synapses remains a major problem. Thus, a high-precision tool to actuate neuronal axon outgrowth in real-time conditions is required to attain robust axon regeneration. This study aims to establish a microfluidic platform for precise and real-time axon outgrowth guidance. METHODS A microfluidic device with a 4 μm thick thin-glass sheet as the neuron culture substrate is fabricated. Surface of the glass sheet is chemically modified to facilitate neuron attachment. Femtosecond (fs) laser is used to engrave the glass sheet to achieve micro-holes, where netrin-1 is released for directing the movement of the neuronal axon. RESULTS Numerical simulation and experimental data demonstrate that netrin-1 gradient is formed after it passes through the micro-hole. The neuronal response results show the outgrowth rate of the axon is significantly increased by netrin-1 gradient. Furthermore, a majority of neuronal axons exhibit guided outgrowth characterized by positive turning angles of axon displacement in the direction of netrin-1 gradients. CONCLUSION Integrating fs laser and microfluidic device facilitates controlled and instantaneous axon outgrowth in a non-invasive manner. SIGNIFICANCE The developed real-time microfluidic platform shows potential in the application for on-site neuronal transplantation, which is significant for the treatment of a range of neurological disorders and injuries.
Collapse
|
5
|
A pendulum-type electrochemical aptamer-based sensor for continuous, real-time and stable detection of proteins. Talanta 2024; 266:125026. [PMID: 37544252 DOI: 10.1016/j.talanta.2023.125026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 07/27/2023] [Accepted: 08/01/2023] [Indexed: 08/08/2023]
Abstract
Continuous detection of proteins is crucial for health management and biomedical research. Electrochemical aptamer-based (E-AB) sensor that relies on binding affinity between a recognition oligonucleotide and its specific target is a versatile platform to fulfill this purpose. Yet, the vast majority of E-AB sensors are characterized by voltammetric methods, which suffer from signal drifts and low-frequency data acquisition during continuous operations. To overcome these limitations, we developed a novel E-AB sensor empowered by Gold nanoparticle-DNA Pendulum (GDP). Using chronoamperometric interrogation, the developed sensor enabled drift-resistant, high-frequency, and real-time monitoring of vascular endothelial growth factor (VEGF), a vital signaling protein that regulates angiogenesis, endothelial cell proliferation and vasculogenesis. We assembled VEGF aptamer-anchored GDP probes to a reduced graphene modified electrode, where a fast chronoamperometric current transient occurs as the GDP rapidly transport to the electrode surface. In the presence of target molecules, longer and concentration-dependent time decays were observed because of slower motion of the GDP in its bound state. After optimizing several decisive parameters, including composition ratios of GDP, probe density, and incubation time, the GDP empowered E-AB sensor achieves continuous, selective, and reversible monitoring of VEGF in both phosphate buffered saline (PBS) solutions and artificial urine with a wide detection range from 13 fM to 130 nM. Moreover, the developed sensor acquires signals on a millisecond timescale, and remains resistant to signal degradation during operation. This study offers a new approach to designing E-AB architectures for continuous biomolecular monitoring.
Collapse
|
6
|
Machine learning implementation strategy in imaging and impedance flow cytometry. BIOMICROFLUIDICS 2023; 17:051506. [PMID: 37900052 PMCID: PMC10613093 DOI: 10.1063/5.0166595] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 10/06/2023] [Indexed: 10/31/2023]
Abstract
Imaging and impedance flow cytometry is a label-free technique that has shown promise as a potential replacement for standard flow cytometry. This is due to its ability to provide rich information and archive high-throughput analysis. Recently, significant efforts have been made to leverage machine learning for processing the abundant data generated by those techniques, enabling rapid and accurate analysis. Harnessing the power of machine learning, imaging and impedance flow cytometry has demonstrated its capability to address various complex phenotyping scenarios. Herein, we present a comprehensive overview of the detailed strategies for implementing machine learning in imaging and impedance flow cytometry. We initiate the discussion by outlining the commonly employed setup to acquire the data (i.e., image or signal) from the cell. Subsequently, we delve into the necessary processes for extracting features from the acquired image or signal data. Finally, we discuss how these features can be utilized for cell phenotyping through the application of machine learning algorithms. Furthermore, we discuss the existing challenges and provide insights for future perspectives of intelligent imaging and impedance flow cytometry.
Collapse
|
7
|
A review on intelligent impedance cytometry systems: Development, applications and advances. Anal Chim Acta 2023; 1269:341424. [PMID: 37290859 DOI: 10.1016/j.aca.2023.341424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 05/22/2023] [Accepted: 05/23/2023] [Indexed: 06/10/2023]
Abstract
Impedance cytometry is a well-established technique for counting and analyzing single cells, with several advantages, such as convenience, high throughput, and no labeling required. A typical experiment consists of the following steps: single-cell measurement, signal processing, data calibration, and particle subtype identification. At the beginning of this article, we compared commercial and self-developed options extensively and provided references for developing reliable detection systems, which are necessary for cell measurement. Then, a number of typical impedance metrics and their relationships to biophysical properties of cells were analyzed with respect to the impedance signal analysis. Given the rapid advances of intelligent impedance cytometry in the past decade, this article also discussed the development of representative machine learning-based approaches and systems, and their applications in data calibration and particle identification. Finally, the remaining challenges facing the field were summarized, and potential future directions for each step of impedance detection were discussed.
Collapse
|
8
|
An optimized PDMS microfluidic device for ultra-fast and high-throughput imaging flow cytometry. LAB ON A CHIP 2023; 23:3571-3580. [PMID: 37401791 DOI: 10.1039/d3lc00237c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/05/2023]
Abstract
Imaging flow cytometry (IFC) is a powerful tool for cell detection and analysis due to its high throughput and compatibility in image acquisition. Optical time-stretch (OTS) imaging is considered as one of the most promising imaging techniques for IFC because it can realize cell imaging at a flow speed of around 60 m s-1. However, existing PDMS-based microchannels cannot function at flow velocities higher than 10 m s-1; thus the capability of OTS-based IFC is significantly limited. To overcome the velocity barrier for PDMS-based microchannels, we proposed an optimized design of PDMS-based microchannels with reduced hydraulic resistance and 3D hydrodynamic focusing capability, which can drive fluids at an ultra-high flow velocity (of up to 40 m s-1) by using common syringe pumps. To verify the feasibility of our design, we fabricated and installed the microchannel in an OTS IFC system. The experimental results first proved that the proposed microchannel can support a stable flow velocity of up to 40 m s-1 without any leakage or damage. Then, we demonstrated that the OTS IFC is capable of imaging cells at a velocity of up to 40 m s-1 with good quality. To the best of our knowledge, it is the first time that IFC has achieved such a high flow velocity just by using a PDMS-glass chip. Moreover, high velocity can enhance the focusing of cells on the optical focal plane, increasing the number of detected cells and the throughput. This work provides a promising solution for IFC to fully release its capability of advanced imaging techniques by operating at an extremely high screening throughput.
Collapse
|
9
|
10 μm thick ultrathin glass sheet to realize a highly sensitive cantilever for precise cell stiffness measurement. LAB ON A CHIP 2023; 23:3651-3661. [PMID: 37449439 DOI: 10.1039/d3lc00113j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/18/2023]
Abstract
The micro-cantilever-based sensor platform has become a promising technique in the sensing area for physical, chemical and biological detection due to its portability, small size, label-free characteristics and good compatibility with "lab-on-a-chip" devices. However, traditional micro-cantilever methods are limited by their complicated fabrication, manipulation and detection, and low sensitivity. In this research, we proposed a 10 μm thick ultrathin, highly sensitive, and flexible glass cantilever integrated with a strain gauge sensor and presented its application for the measurement of single-cell mechanical properties. Compared to conventional methods, the proposed ultrathin glass sheet (UTGS)-based cantilever is easier to fabricate, has better physical and chemical properties, and shows a high linear relationship between resistance change and applied small force or displacement. The sensitivity of the cantilever is 15 μN μm-1 and the minimum detectable displacement at the current development stage is 500 nm, which is sufficient for cell stiffness measurement. The cantilever also possesses excellent optical transparency that supports real-time observation during measurement. We first calibrated the cantilever by measuring the Young's modulus of PDMS with known specific stiffness, and then we demonstrated the measurement of Xenopus oocytes and fertilized eggs in different statuses. By further optimizing the UTGS-based cantilever, we can extend its applicability to various measurements of different cells.
Collapse
|
10
|
Inertial Separation of Particles Assisted by Symmetrical Sheath Flows in a Straight Microchannel. Anal Chem 2023. [PMID: 37455389 DOI: 10.1021/acs.analchem.3c02089] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2023]
Abstract
Over the past two decades, inertial microfluidics, which works at an intermediate range of Reynolds number (∼1 < Re < ∼100), has been widely used for particle separation due to its high-throughput and label-free features. This work proposes a novel method for continuous separation of particles by size using inertial microfluidics, with the assistance of symmetrical sheath flows in a straight microchannel. Here, larger particles (>3 μm) are arranged close to the channel sidewalls, while smaller particles (<2 μm) remain flowing along the channel centerline. This conclusion is supported by experimental data with particles of different sizes ranging from 0.79 to 10.5 μm. Symmetrical Newtonian sheath flows are injected on both sides of particle mixtures into a straight rectangular microchannel with an aspect ratio (AR = height/width) of 2.5. Results show that the separation performance of the developed microfluidic device is affected by three main factors: channel length, total flow rate, and flow rate ratio of sheath to sample. Besides, separation of platelets from whole blood is demonstrated. The developed microfluidic platform owns the advantages of low fabrication cost, simple experiment setup, versatile selections of particle candidates, and stable operations. This systematic study provides a new perspective for particle separation, which is expected to find applications across various fields spanning physics, biology, biomedicine, and industry.
Collapse
|
11
|
Microfluidic Separation and Enrichment of Escherichia coli by Size Using Viscoelastic Flows. Anal Chem 2023; 95:2561-2569. [PMID: 36656064 DOI: 10.1021/acs.analchem.2c05084] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Here, we achieve the separation and enrichment of Escherichia coli clusters from its singlets in a viscoelastic microfluidic device. E. coli, an important prokaryotic model organism and a widely used microbial factory, can aggregate in clusters, leading to biofilm development that can be detrimental to human health and industrial processes. The ability to obtain high-purity populations of E. coli clusters is of significance for biological, biomedical, and industrial applications. In this study, polystyrene particles of two different sizes, 1 and 4.8 μm, are used to mimic E. coli singlets and clusters, respectively. Experimental results show that particles migrate toward the channel center in a size-dependent manner, due to the combined effects of inertial and elastic forces; 4.8 and 1 μm particles are found to have lateral equilibrium positions closer to the channel centerline and sidewalls, respectively. The size-dependent separation performance of the microdevice is demonstrated to be affected by three main factors: channel length, the ratio of sheath to sample flow rate, and poly(ethylene oxide) (PEO) concentration. Further, the separation of E. coli singlets and clusters is achieved at the outlets, and the separation efficiency is evaluated in terms of purity and enrichment factor.
Collapse
|
12
|
Parallel Impedance Cytometry for Real-Time Screening of Bacterial Single Cells from Nano- to Microscale. ACS Sens 2022; 7:3700-3709. [PMID: 36203240 DOI: 10.1021/acssensors.2c01351] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The benefits of impedance cytometry include high-throughput and label-free detection, while long-term calibration is required to remove the effects of the detection circuits. This study presents a novel impedance cytometry system, called parallel impedance cytometry, to simplify the calibration and analysis of the impedance signals. Furthermore, target objects can be detected even when benchmarked against similar objects. Parallel dual microchannels allow the simultaneous detection of reference and target particles in two separate microchannels, without the premixing of reference and target suspensions. The impedance pulses of both can appear separately on the opposite sides of the same time series, which have been verified via simulation and experimental results. Raw impedance signals can easily distinguish target particles from reference ones. Polystyrene beads with different sizes ranging from nano- to microscale (e.g., 500, 750 nm, 1, 2, 3, and 4.5 μm) confirm the nanosensitivity of the system. In addition, the detection of antibiotic-treated Escherichia coli cells demonstrates that our system can be used for the quantitative assessment of the dielectric properties of individual cells, as well as for the proportion of susceptible cells. Through benchmarking against untreated E. coli cells in the other channel, our method enables the discrimination of susceptible cells from others and the comparison of susceptible and insusceptible cells in the target suspension. Those findings indicate that the parallel impedance cytometry can greatly facilitate the measurement and calibration of the impedances of various particles or cells and provide a means to compare their dielectric properties.
Collapse
|
13
|
Microenvironmental Analysis and Control for Local Cells under Confluent Conditions via a Capillary-Based Microfluidic Device. Anal Chem 2022; 94:16299-16307. [DOI: 10.1021/acs.analchem.2c02815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
14
|
Identification of Single Yeast Budding Using Impedance Cytometry with a Narrow Electrode Span. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22207743. [PMID: 36298094 PMCID: PMC9609181 DOI: 10.3390/s22207743] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 10/10/2022] [Accepted: 10/11/2022] [Indexed: 06/10/2023]
Abstract
Impedance cytometry is wildly used in single-cell detection, and its sensitivity is essential for determining the status of single cells. In this work, we focus on the effect of electrode gap on detection sensitivity. Through comparing the electrode span of 1 µm and 5 µm, our work shows that narrowing the electrode span could greatly improve detection sensitivity. The mechanism underlying the sensitivity improvement was analyzed via numerical simulation. The small electrode gap (1 µm) allows the electric field to concentrate near the detection area, resulting in a high sensitivity for tiny particles. This finding is also verified with the mixture suspension of 1 µm and 3 µm polystyrene beads. As a result, the electrodes with 1 µm gap can detect more 1 µm beads in the suspension than electrodes with 5 µm gap. Additionally, for single yeast cells analysis, it is found that impedance cytometry with 1 µm electrodes gap can easily distinguish budding yeast cells, which cannot be realized by the impedance cytometry with 5 µm electrodes gap. All experimental results support that narrowing the electrode gap is necessary for tiny particle detection, which is an important step in the development of submicron and nanoscale impedance cytometry.
Collapse
|
15
|
Anhydrobiotic chironomid larval motion-based multi-sensing microdevice for the exploration of survivable locations. iScience 2022; 25:104639. [PMID: 36039361 PMCID: PMC9418600 DOI: 10.1016/j.isci.2022.104639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 05/31/2022] [Accepted: 06/14/2022] [Indexed: 11/30/2022] Open
Abstract
African chironomid (Polypedilum vanderplanki) larvae can suspend their metabolism by undergoing severe desiccation and then resume this activity by simple rehydration. We present a microdevice using interdigital comb electrodes to detect the larval motion using the natural surface charge of the living larvae in water. The larvae were most active 2 h after soaking them in water at 30°C; they exhibited motions with 2 Hz frequency. This was comparable to the signal obtained from the microdevice via fast Fourier transform (FFT) processing. The amplitude of the voltage and current were 0.11 mV and 730 nA, respectively. They would be enough to be detected by a low power consumption microcomputer. Temperature and pH sensing were demonstrated by detecting the vital motions of the revived larvae under different conditions. This multi-functional biosensor will be a useful microdevice to search for survivable locations under extreme environmental conditions like those on other planets. A biosensor using anhydrobiotic chironomid larva was created Interdigital comb electrodes were fabricated to detect the larvae motion Multi-parameters such as temperature or pH can be detected The device can search survivable locations under extreme environmental conditions
Collapse
|
16
|
Recent advances in microfluidic devices for single-cell cultivation: methods and applications. LAB ON A CHIP 2022; 22:1438-1468. [PMID: 35274649 DOI: 10.1039/d1lc01030a] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Single-cell analysis is essential to improve our understanding of cell functionality from cellular and subcellular aspects for diagnosis and therapy. Single-cell cultivation is one of the most important processes in single-cell analysis, which allows the monitoring of actual information of individual cells and provides sufficient single-cell clones and cell-derived products for further analysis. The microfluidic device is a fast-rising system that offers efficient, effective, and sensitive single-cell cultivation and real-time single-cell analysis conducted either on-chip or off-chip. Here, we introduce the importance of single-cell cultivation from the aspects of cellular and subcellular studies. We highlight the materials and structures utilized in microfluidic devices for single-cell cultivation. We further discuss biological applications utilizing single-cell cultivation-based microfluidics, such as cellular phenotyping, cell-cell interactions, and omics profiling. Finally, present limitations and future prospects of microfluidics for single-cell cultivation are also discussed.
Collapse
|
17
|
Dual-frequency impedance assays for intracellular components in microalgal cells. LAB ON A CHIP 2022; 22:550-559. [PMID: 35072196 DOI: 10.1039/d1lc00721a] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Intracellular components (including organelles and biomolecules) at the submicron level are typically analyzed in situ by special preparation or expensive setups. Here, a label-free and cost-effective approach of screening microalgal single-cells at a subcellular resolution is available based on impedance cytometry. To the best of our knowledge, it is the first time that the relationships between impedance signals and submicron intracellular organelles and biomolecules are shown. Experiments were performed on Euglena gracilis (E. gracilis) cells incubated under different incubation conditions (i.e., aerobic and anaerobic) and 15 μm polystyrene beads (reference) at two distinct stimulation frequencies (i.e., 500 kHz and 6 MHz). Based on the impedance detection of tens of thousands of samples at a throughput of about 900 cells per second, three metrics were used to track the changes in biophysical properties of samples. As a result, the electrical diameters of cells showed a clear shrinkage in cell volume and intracellular components, as observed under a microscope. The morphology metric of impedance pulses (i.e., tilt index) successfully characterized the changes in cell shape and intracellular composition distribution. Besides, the electrical opacity showed a stable ratio of the intracellular components to cell volume under the cellular self-regulation. Additionally, simulations were used to support these findings and to elucidate how submicron intracellular components and cell morphology affect impedance signals, providing a basis for future improvements. This work opens up a label-free and high-throughput way to analyze single-cell intracellular components by impedance cytometry.
Collapse
|
18
|
Assessment of the electrical penetration of cell membranes using four-frequency impedance cytometry. MICROSYSTEMS & NANOENGINEERING 2022; 8:68. [PMID: 35757522 PMCID: PMC9226050 DOI: 10.1038/s41378-022-00405-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 05/16/2022] [Accepted: 05/30/2022] [Indexed: 05/02/2023]
Abstract
The electrical penetration of the cell membrane is vital for determining the cell interior via impedance cytometry. Herein, we propose a method for determining the conductivity of the cell membrane through the tilting levels of impedance pulses. When electrical penetration occurs, a high-frequency current freely passes through the cell membrane; thus, the intracellular distribution can directly act on the high-frequency impedance pulses. Numerical simulation shows that an uneven intracellular component distribution can affect the tilting levels of impedance pulses, and the tilting levels start increasing when the cell membrane is electrically penetrated. Experimental evidence shows that higher detection frequencies (>7 MHz) lead to a wider distribution of the tilting levels of impedance pulses when measuring cell populations with four-frequency impedance cytometry. This finding allows us to determine that a detection frequency of 7 MHz is able to pass through the membrane of Euglena gracilis (E. gracilis) cells. Additionally, we provide a possible application of four-frequency impedance cytometry in the biomass monitoring of single E. gracilis cells. High-frequency impedance (≥7 MHz) can be applied to monitor these biomass changes, and low-frequency impedance (<7 MHz) can be applied to track the corresponding biovolume changes. Overall, this work demonstrates an easy determination method for the electrical penetration of the cell membrane, and the proposed platform is applicable for the multiparameter assessment of the cell state during cultivation.
Collapse
|
19
|
Specific capture and intact release of breast cancer cells using a twin-layer vein-shaped microchip with a self-assembled surface. NANOSCALE 2021; 13:17765-17774. [PMID: 34558589 DOI: 10.1039/d1nr04018a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Breast cancer is the most fatal disease among female cancers yet its detection still relies on needle biopsy. The unique physical and immune characteristics of breast cancer cells different from blood cells make them suitable to be employed as excellent biomarkers in liquid biopsy, through which breast cancer cells are collected from peripheral blood for further cancer diagnosis, medical treatment monitoring, and drug screening. Although the separation and enrichment of breast cancer cells from peripheral blood have been studied for years, there are still two problems to be solved in these methods: the low efficiency of on-chip immunologic capture in the flow state and the influence of the conjugated antibodies for the following analyses during cell release. In this paper, a vein-shaped microchip with self-assembled surface was developed for the specific and robust capture (91.2%) of breast cancer cells in the flow state. A protein-recovery process was proposed, in which trypsin served as a mild release reagent, releasing 92% of cells with high viability (96%), normal adherent proliferation, and complete proteins on the cell membrane, avoiding disturbance of the conjugated chemical molecules in the following clinical study. The excellent performance demonstrated in isolating free breast cancer cells from real peripheral blood sample, originating from the orthotopic 4T1 breast cancer metastatic models, suggest the microchip could be utilized as a multiple circulating tumor cell capture and release platform that could allow providing more reliable information in liquid biopsies.
Collapse
|
20
|
Microscopic impedance cytometry for quantifying single cell shape. Biosens Bioelectron 2021; 193:113521. [PMID: 34380102 DOI: 10.1016/j.bios.2021.113521] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/22/2021] [Accepted: 07/15/2021] [Indexed: 02/02/2023]
Abstract
In this work, we investigated the ability of impedance flow cytometry to measure the shape of single cells/particles. We found that the impedance pulses triggered by micro-objects that are asymmetric in morphology show a tilting trend, and there is no such a tilting trend for symmetric ones. Therefore, we proposed a new metric, tilt index, to quantify the tilt level of the impedance pulses. Through simulation, we found that the value of tilt index tends to be zero for perfectly symmetrical objects, while the value is greater than zero for asymmetrical ones. Also, this metric was found to be independent on the trajectories (i.e., lateral, and z-direction shift) of the target micro-object. In experiments, we adopted a home-made lock-in amplifier and performed experiments on 10 μm polystyrene beads and Euglena gracilis (E. gracilis) cells with varying shapes. The experimental results coincided with the simulation results and demonstrated that the new metric (tilt index) enables the impedance cytometry to characterize the shape single cells/particles without microscopy or other optical setups.
Collapse
|
21
|
Hydrodynamic particle focusing enhanced by femtosecond laser deep grooving at low Reynolds numbers. Sci Rep 2021; 11:1652. [PMID: 33462348 PMCID: PMC7813873 DOI: 10.1038/s41598-021-81190-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 01/04/2021] [Indexed: 02/08/2023] Open
Abstract
Microfluidic focusing of particles (both synthetic and biological), which enables precise control over the positions of particles in a tightly focused stream, is a prerequisite step for the downstream processing, such as detection, trapping and separation. In this study, we propose a novel hydrodynamic focusing method by taking advantage of open v-shaped microstructures on a glass substrate engraved by femtosecond pulse (fs) laser. The fs laser engraved microstructures were capable of focusing polystyrene particles and live cells in rectangular microchannels at relatively low Reynolds numbers (Re). Numerical simulations were performed to explain the mechanisms of particle focusing and experiments were carried out to investigate the effects of groove depth, groove number and flow rate on the performance of the groove-embedded microchannel for particle focusing. We found out that 10-µm polystyrene particles are directed toward the channel center under the effects of the groove-induced secondary flows in low-Re flows, e.g. Re < 1. Moreover, we achieved continuous focusing of live cells with different sizes ranging from 10 to 15 µm, i.e. human T-cell lymphoma Jurkat cells, rat adrenal pheochromocytoma PC12 cells and dog kidney MDCK cells. The glass grooves fabricated by fs laser are expected to be integrated with on-chip detection components, such as contact imaging and fluorescence lifetime-resolved imaging, for various biological and biomedical applications, where particle focusing at a relatively low flow rate is desirable.
Collapse
|
22
|
In situ measurement of cell stiffness of Arabidopsis roots growing on a glass micropillar support by atomic force microscopy. PLANT BIOTECHNOLOGY (TOKYO, JAPAN) 2020; 37:417-422. [PMID: 33850428 PMCID: PMC8034704 DOI: 10.5511/plantbiotechnology.20.1016a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 10/16/2020] [Indexed: 05/25/2023]
Abstract
Atomic force microscopy (AFM) can measure the mechanical properties of plant tissue at the cellular level, but for in situ observations, the sample must be held in place on a rigid support and it is difficult to obtain accurate data for living plants without inhibiting their growth. To investigate the dynamics of root cell stiffness during seedling growth, we circumvented these problems by using an array of glass micropillars as a support to hold an Arabidopsis thaliana root for AFM measurements without inhibiting root growth. The root elongated in the gaps between the pillars and was supported by the pillars. The AFM cantilever could contact the root for repeated measurements over the course of root growth. The elasticity of the root epidermal cells was used as an index of the stiffness. By contrast, we were not able to reliably observe roots on a smooth glass substrate because it was difficult to retain contact between the root and the cantilever without the support of the pillars. Using adhesive to fix the root on the smooth glass plane overcame this issue, but prevented root growth. The glass micropillar support allowed reproducible measurement of the spatial and temporal changes in root cell elasticity, making it possible to perform detailed AFM observations of the dynamics of root cell stiffness.
Collapse
|
23
|
Mechanical properties of single cells: Measurement methods and applications. Biotechnol Adv 2020; 45:107648. [DOI: 10.1016/j.biotechadv.2020.107648] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/11/2020] [Accepted: 10/12/2020] [Indexed: 12/22/2022]
|
24
|
Establishment of a heart-on-a-chip microdevice based on human iPS cells for the evaluation of human heart tissue function. Sci Rep 2020. [DOI: 10.1201/9781420010138] [Citation(s) in RCA: 1419] [Impact Index Per Article: 354.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Abstract
Human iPS cell (iPSC)-derived cardiomyocytes (CMs) hold promise for drug discovery for heart diseases and cardiac toxicity tests. To utilize human iPSC-derived CMs, the establishment of three-dimensional (3D) heart tissues from iPSC-derived CMs and other heart cells, and a sensitive bioassay system to depict physiological heart function are anticipated. We have developed a heart-on-a-chip microdevice (HMD) as a novel system consisting of dynamic culture-based 3D cardiac microtissues derived from human iPSCs and microelectromechanical system (MEMS)-based microfluidic chips. The HMDs could visualize the kinetics of cardiac microtissue pulsations by monitoring particle displacement, which enabled us to quantify the physiological parameters, including fluidic output, pressure, and force. The HMDs demonstrated a strong correlation between particle displacement and the frequency of external electrical stimulation. The transition patterns were validated by a previously reported versatile video-based system to evaluate contractile function. The patterns are also consistent with oscillations of intracellular calcium ion concentration of CMs, which is a fundamental biological component of CM contraction. The HMDs showed a pharmacological response to isoproterenol, a β-adrenoceptor agonist, that resulted in a strong correlation between beating rate and particle displacement. Thus, we have validated the basic performance of HMDs as a resource for human iPSC-based pharmacological investigations.
Collapse
|
25
|
Establishment of a heart-on-a-chip microdevice based on human iPS cells for the evaluation of human heart tissue function. Sci Rep 2020; 10:19201. [PMID: 33154509 PMCID: PMC7645446 DOI: 10.1038/s41598-020-76062-w] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 10/23/2020] [Indexed: 12/04/2022] Open
Abstract
Human iPS cell (iPSC)-derived cardiomyocytes (CMs) hold promise for drug discovery for heart diseases and cardiac toxicity tests. To utilize human iPSC-derived CMs, the establishment of three-dimensional (3D) heart tissues from iPSC-derived CMs and other heart cells, and a sensitive bioassay system to depict physiological heart function are anticipated. We have developed a heart-on-a-chip microdevice (HMD) as a novel system consisting of dynamic culture-based 3D cardiac microtissues derived from human iPSCs and microelectromechanical system (MEMS)-based microfluidic chips. The HMDs could visualize the kinetics of cardiac microtissue pulsations by monitoring particle displacement, which enabled us to quantify the physiological parameters, including fluidic output, pressure, and force. The HMDs demonstrated a strong correlation between particle displacement and the frequency of external electrical stimulation. The transition patterns were validated by a previously reported versatile video-based system to evaluate contractile function. The patterns are also consistent with oscillations of intracellular calcium ion concentration of CMs, which is a fundamental biological component of CM contraction. The HMDs showed a pharmacological response to isoproterenol, a β-adrenoceptor agonist, that resulted in a strong correlation between beating rate and particle displacement. Thus, we have validated the basic performance of HMDs as a resource for human iPSC-based pharmacological investigations.
Collapse
|
26
|
Area cooling enables thermal positioning and manipulation of single cells. LAB ON A CHIP 2020; 20:3733-3743. [PMID: 33000103 DOI: 10.1039/d0lc00523a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Contactless particle manipulation based on a thermal field has shown great potential for biological, medical, and materials science applications. However, thermal diffusion from a high-temperature area causes thermal damage to bio-samples. Besides, the permanent bonding of a sample chamber onto microheater substrates requires that the thermal field devices be non-disposable. These limitations impede use of the thermal manipulation approach. Here, a novel manipulation platform is proposed that combines microheaters and an area cooling system to produce enough force to steer sedimentary particles or cells and to limit the thermal diffusion. It uses the one-time fabricated motherboard and an exchangeable sample chamber that provides disposable use. Sedimentary objects can be steered to the bottom center of the thermal field by combined thermal convection and thermophoresis. Single particle or cell manipulation is realized by applying multiple microheaters in the platform. Results of a cell viability test confirmed the method's compatibility in biology fields. With its advantages of biocompatibility for live cells, operability for different sizes of particles and flexibility of platform fabrication, this novel manipulation platform has a high potential to become a powerful tool for biology research.
Collapse
|
27
|
Abstract
Sub-micrometer particles (0.10-1.0 μm) are of great significance to study, e.g., microvesicles and protein aggregates are targets for therapeutic intervention, and sub-micrometer fluorescent polystyrene (PS) particles are used as probes for diagnostic imaging. Focusing of sub-micrometer particles - precisely control over the position of sub-micrometer particles in a tightly focused stream - has a wide range of applications in the field of biology, chemistry and environment, by acting as a prerequisite step for downstream detection, manipulation and quantification. Microfluidic devices have been attracting great attention as desirable tools for sub-micrometer particle focusing, due to their small size, low reagent consumption, fast analysis and low cost. Recent advancements in fundamental knowledge and fabrication technologies have enabled microfluidic focusing of particles at sub-micrometer scale in a continuous, label-free and high-throughput manner. Microfluidic methods for the focusing of sub-micrometer particles can be classified into two main groups depending on whether an external field is applied: 1) passive methods, which utilize intrinsic fluidic properties without the need of external actuation, such as inertial, deterministic lateral displacement (DLD), viscoelastic and hydrophoretic focusing; and 2) active methods, where external fields are used, such as dielectrophoretic, thermophoretic, acoustophoretic and optical focusing. This article mainly reviews the studies on the focusing of sub-micrometer particles in microfluidic devices over the past 10 years. It aims to bridge the gap between the focusing of micrometer and nanometer scale (1.0-100 nm) particles and to improve the understanding of development progress, current advances and future prospects in microfluidic focusing techniques.
Collapse
|
28
|
Sheathless Inertial Focusing Chip Combining a Spiral Channel with Periodic Expansion Structures for Efficient and Stable Particle Sorting. Anal Chem 2020; 92:1833-1841. [PMID: 31858787 DOI: 10.1021/acs.analchem.9b03692] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Efficient and reliable manipulation of biological particles is crucial in medical diagnosis and chemical synthesis. Inertial microfluidic devices utilizing passive hydrodynamic forces in the secondary flow have drawn considerable attention for their high throughputs, low costs, and harmless particle manipulation. However, as the dominant mechanism, the inertial lift force is difficult to quantitatively analyze because of the uncertainties of its magnitude and direction. The equilibrium position of particles varies along the migration process, thus inducing the instabilities of particle separation. Herein, we present a designable inertial microfluidic chip combining a spiral channel with periodic expansion structures for the sheathless separation of particles with different sizes. The stable vortex-induced lift force arising from the periodic expansion and the Dean drag force significantly enhanced the focusing process and determined the final equilibrium position. The experimental results showed that over 99% of target particles could be isolated with the high target sample purity of 86.12%. In the biological experiment, 93.5% of the MCF-7, 89.5% of the Hela, and 88.6% of the A549 cells were steadily recovered with excellent viabilities to verify the potential of the device in dealing with biological particles over a broad range of throughputs. The device presented in this study can further serve as a lab-on-chip platform for liquid biopsy and diagnostic analysis.
Collapse
|
29
|
Effects of Flow‐Induced Microfluidic Chip Wall Deformation on Imaging Flow Cytometry. Cytometry A 2019; 97:909-920. [DOI: 10.1002/cyto.a.23944] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 11/04/2019] [Accepted: 11/20/2019] [Indexed: 12/19/2022]
|
30
|
Intelligent whole-blood imaging flow cytometry for simple, rapid, and cost-effective drug-susceptibility testing of leukemia. LAB ON A CHIP 2019; 19:2688-2698. [PMID: 31287108 DOI: 10.1039/c8lc01370e] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Drug susceptibility (also called chemosensitivity) is an important criterion for developing a therapeutic strategy for various cancer types such as breast cancer and leukemia. Recently, functional assays such as high-content screening together with genomic analysis have been shown to be effective for predicting drug susceptibility, but their clinical applicability is poor since they are time-consuming (several days long), labor-intensive, and costly. Here we present a highly simple, rapid, and cost-effective liquid biopsy for ex vivo drug-susceptibility testing of leukemia. The method is based on an extreme-throughput (>1 million cells per second), label-free, whole-blood imaging flow cytometer with a deep convolutional autoencoder, enabling image-based identification of the drug susceptibility of every single white blood cell in whole blood within 24 hours by simply flowing a drug-treated whole blood sample as little as 500 μL into the imaging flow cytometer without labeling. Our results show that the method accurately evaluates the drug susceptibility of white blood cells from untreated patients with acute lymphoblastic leukemia. Our method holds promise for affordable precision medicine.
Collapse
|
31
|
Isolating Single Euglena gracilis Cells by Glass Microfluidics for Raman Analysis of Paramylon Biogenesis. Anal Chem 2019; 91:9631-9639. [DOI: 10.1021/acs.analchem.9b01007] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
32
|
A valve powered by earthworm muscle with both electrical and 100% chemical control. Sci Rep 2019; 9:8042. [PMID: 31285453 PMCID: PMC6614428 DOI: 10.1038/s41598-019-44116-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 05/07/2019] [Indexed: 01/09/2023] Open
Abstract
Development of bio-microactuators combining microdevices and cellular mechanical functions has been an active research field owing to their desirable properties including high mechanical integrity and biocompatibility. Although various types of devices were reported, the use of as-is natural muscle tissue should be more effective. An earthworm muscle-driven valve has been created. Long-time (more than 2 min) and repeatable displacement was observed by chemical (acetylcholine) stimulation. The generated force of the muscle (1 cm × 3 cm) was 1.57 mN on average for 2 min by the acetylcholine solution (100 mM) stimulation. We demonstrated an on-chip valve that stopped the constant pressure flow by the muscle contraction. For electrical control, short pulse stimulation was used for the continuous and repeatable muscle contraction. The response time was 3 s, and the pressure resistance was 3.0 kPa. Chemical stimulation was then used for continuous muscle contraction. The response time was 42 s, and the pressure resistance was 1.5 kPa. The ON (closed) state was kept for at least 2 min. An on-chip valve was demonstrated that stopped the constant pressure flow by the muscle contraction. This is the first demonstration of the muscle-based valve that is 100% chemically actuated and controlled.
Collapse
|
33
|
Enhancement in acoustic focusing of micro and nanoparticles by thinning a microfluidic device. ROYAL SOCIETY OPEN SCIENCE 2019; 6:181776. [PMID: 30891287 PMCID: PMC6408367 DOI: 10.1098/rsos.181776] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 01/23/2019] [Indexed: 05/04/2023]
Abstract
The manipulation of micro/nanoparticles has become increasingly important in biological and industrial fields. As a non-contact method for particle manipulation, acoustic focusing has been applied in sorting, enrichment and analysis of particles with microfluidic devices. Although the frequency and amplitude of acoustic waves and the dimensions of microchannels have been recognized as important parameters for acoustic focusing, the thickness of microfluidic devices has not been considered so far. Here, we report that thin glass microfluidic devices enhance acoustic focusing of micro/nanoparticles. It was found that the thickness of a microfluidic device strongly influences its ability to focus particles via acoustic radiation, because the energy propagation of acoustic waves is affected by the total mass of the device. Acoustic focusing of submicrometre polystyrene beads and Escherichia coli as well as enrichment of polystyrene beads were achieved in glass microfluidic devices as thin as 0.4 mm. Modifying the thickness of a microfluidic device can thus serve as a critical parameter for acoustic focusing when conventional parameters to achieve this effect are kept unchanged. Thus, our findings enable new approaches to the design of novel microfluidic devices.
Collapse
|
34
|
Time Sequential Single-Cell Patterning with High Efficiency and High Density. SENSORS 2018; 18:s18113672. [PMID: 30380644 PMCID: PMC6264106 DOI: 10.3390/s18113672] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Revised: 10/24/2018] [Accepted: 10/25/2018] [Indexed: 12/24/2022]
Abstract
Single-cell capture plays an important role in single-cell manipulation and analysis. This paper presents a microfluidic device for deterministic single-cell trapping based on the hydrodynamic trapping mechanism. The device is composed of an S-shaped loop channel and thousands of aligned trap units. This arrayed structure enables each row of the device to be treated equally and independently, as it has row periodicity. A theoretical model was established and a simulation was conducted to optimize the key geometric parameters, and the performance was evaluated by conducting experiments on MCF-7 and Jurkat cells. The results showed improvements in single-cell trapping ability, including loading efficiency, capture speed, and the density of the patterned cells. The optimized device can achieve a capture efficiency of up to 100% and single-cell capture efficiency of up to 95%. This device offers 200 trap units in an area of 1 mm2, which enables 100 single cells to be observed simultaneously using a microscope with a 20× objective lens. One thousand cells can be trapped sequentially within 2 min; this is faster than the values obtained with previously reported devices. Furthermore, the cells can also be recovered by reversely infusing solutions. The structure can be easily extended to a large scale, and a patterned array with 32,000 trap sites was accomplished on a single chip. This device can be a powerful tool for high-throughput single-cell analysis, cell heterogeneity investigation, and drug screening.
Collapse
|
35
|
Intelligent Image-Activated Cell Sorting. Cell 2018; 175:266-276.e13. [DOI: 10.1016/j.cell.2018.08.028] [Citation(s) in RCA: 298] [Impact Index Per Article: 49.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 08/09/2018] [Accepted: 08/15/2018] [Indexed: 11/27/2022]
|
36
|
Ultrasensitive detection of nucleic acids based on dually enhanced fluorescence polarization. Analyst 2018; 143:3560-3569. [DOI: 10.1039/c8an00952j] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Increase of the molecular volume and quenching effect induced by AuNP conjugation can both enhance the fluorescence polarization of Alexa488.
Collapse
|
37
|
Optofluidic time-stretch quantitative phase microscopy. Methods 2017; 136:116-125. [PMID: 29031836 DOI: 10.1016/j.ymeth.2017.10.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 10/02/2017] [Accepted: 10/04/2017] [Indexed: 11/18/2022] Open
Abstract
Innovations in optical microscopy have opened new windows onto scientific research, industrial quality control, and medical practice over the last few decades. One of such innovations is optofluidic time-stretch quantitative phase microscopy - an emerging method for high-throughput quantitative phase imaging that builds on the interference between temporally stretched signal and reference pulses by using dispersive properties of light in both spatial and temporal domains in an interferometric configuration on a microfluidic platform. It achieves the continuous acquisition of both intensity and phase images with a high throughput of more than 10,000 particles or cells per second by overcoming speed limitations that exist in conventional quantitative phase imaging methods. Applications enabled by such capabilities are versatile and include characterization of cancer cells and microalgal cultures. In this paper, we review the principles and applications of optofluidic time-stretch quantitative phase microscopy and discuss its future perspective.
Collapse
|
38
|
Embryonic body culturing in an all-glass microfluidic device with laser-processed 4 μm thick ultra-thin glass sheet filter. Biomed Microdevices 2017; 19:85. [PMID: 28929304 DOI: 10.1007/s10544-017-0227-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
In this paper, we report the development and demonstration of a method to fabricate an all-glass microfluidic cell culturing device without circulation flow. On-chip microfluidic cell culturing is an indispensable technique for cellular replacement therapies and experimental cell biology. Polydimethylsiloxane (PDMS) have become a popular material for fabricating microfluidic cell culture devices because it is a transparent, biocompatible, deformable, easy-to-mold, and gas-permeable. However, PDMS is also a chemically and physically unstable material. For example, PDMS undergoes aging easily even in room temperature conditions. Therefore, it is difficult to control long term experimental culturing conditions. On the other hand, glass is expected to be stable not only in physically but also chemically even in the presence of organic solvents. However, cell culturing still requires substance exchanges such as gases and nutrients, and so on, which cannot be done in a closed space of a glass device without circulation flow that may influence cell behavior. Thus, we introduce a filter structure with micropores onto a glass device to improve permeability to the cell culture space. Normally, it is extremely difficult to fabricate a filter structure on a normal glass plate by using a conventional fabrication method. Here, we demonstrated a method for fabricating an all-glass microfluidic cell culturing device having filters structure. The function of this all-glass culturing device was confirmed by culturing HeLa, fibroblast and ES cells. Compared with the closed glass devices without a filter structure, the numbers of cells in our device increased and embryonic bodies (EBs) were formed. This method offers a new tool in microfluidic cell culture technology for biological analysis and it expands the field of microfluidic cell culture.
Collapse
|
39
|
High-throughput, label-free, single-cell, microalgal lipid screening by machine-learning-equipped optofluidic time-stretch quantitative phase microscopy. Cytometry A 2017; 91:494-502. [PMID: 28399328 DOI: 10.1002/cyto.a.23084] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 01/19/2017] [Accepted: 01/23/2017] [Indexed: 12/16/2022]
Abstract
The development of reliable, sustainable, and economical sources of alternative fuels to petroleum is required to tackle the global energy crisis. One such alternative is microalgal biofuel, which is expected to play a key role in reducing the detrimental effects of global warming as microalgae absorb atmospheric CO2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid amounts and fail to characterize a diverse population of microalgal cells with single-cell resolution in a non-invasive and interference-free manner. Here high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy was demonstrated. In particular, Euglena gracilis, an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement), within lipid droplets was investigated. The optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch quantitative phase microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase maps of every single cell at a high throughput of 10,000 cells/s, enabling accurate cell classification without the need for fluorescent staining. Specifically, the dataset was used to characterize heterogeneous populations of E. gracilis cells under two different culture conditions (nitrogen-sufficient and nitrogen-deficient) and achieve the cell classification with an error rate of only 2.15%. The method holds promise as an effective analytical tool for microalgae-based biofuel production. © 2017 International Society for Advancement of Cytometry.
Collapse
|
40
|
A Method of Three-Dimensional Micro-Rotational Flow Generation for Biological Applications. MICROMACHINES 2016; 7:E140. [PMID: 30404312 PMCID: PMC6190094 DOI: 10.3390/mi7080140] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 06/28/2016] [Accepted: 07/29/2016] [Indexed: 01/01/2023]
Abstract
We report a convenient method to create a three-dimensional micro-rotational fluidic platform for biological applications in the direction of a vertical plane (out-of-plane) without contact in an open space. Unlike our previous complex fluidic manipulation system, this method uses a micro-rotational flow generated near a single orifice when the solution is pushed from the orifice by using a single pump. The three-dimensional fluidic platform shows good potential for fluidic biological applications such as culturing, stimulating, sorting, and manipulating cells. The pattern and velocity of the micro-rotational flow can be controlled by tuning the parameters such as the flow rate and the liquid-air interface height. We found that bio-objects captured by the micro-rotational flow showed self-rotational motion and orbital motion. Furthermore, the path length and position, velocity, and pattern of the orbital motion of the bio-object could be controlled. To demonstrate our method, we used embryoid body cells. As a result, the orbital motion had a maximum length of 2.4 mm, a maximum acceleration of 0.63 m/s², a frequency of approximately 0.45 Hz, a maximum velocity of 15.4 mm/s, and a maximum rotation speed of 600 rpm. The capability to have bio-objects rotate or move orbitally in three dimensions without contact opens up new research opportunities in three-dimensional microfluidic technology.
Collapse
|
41
|
An all-glass 12 μm ultra-thin and flexible micro-fluidic chip fabricated by femtosecond laser processing. LAB ON A CHIP 2016; 16:2427-33. [PMID: 27225521 DOI: 10.1039/c6lc00132g] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This study investigated and established a method, using femtosecond laser processing, to fabricate a 100%-glass-based 12 μm ultra-thin and flexible micro-fluidic chip. First we investigated the suitable pulse energy of the laser to fabricate ultra-thin glass sheets and then we fabricated a prototype glass micro-fluidic chip. Two 1 mm-in-diameter orifices for facilitating alignment in the bonding step and one channel with a width of 20 μm and a length of 25 mm were fabricated in a 4 μm thickness ultra-thin glass sheet using the femtosecond laser; this forms layer 2 in the completed device. Next, the glass sheet with the channel was sandwiched between another glass sheet having an inlet hole and an outlet hole (layer 1) and a base glass sheet (layer 3); the three sheets were bonded to each other, resulting in a flexible, 100%-glass micro-fluidic chip with a thickness of approximately 12 μm and a weight of 3.6 mg. The basic function of the glass micro-fluidic chip was confirmed by flowing 1 and 2 μm in-diameter bead particles through the channel. The fabrication method clearly scales down the thickness limitation of flexible glass devices and offers a possible element technology for fabricating ultra-thin glass devices that can be applied to convection-enhanced delivery, implantable medical devices, wearable devices, and high-resolution imaging of small biological objects such as bacteria and proteins in the channel.
Collapse
|
42
|
Large-Scale Integration of All-Glass Valves on a Microfluidic Device. MICROMACHINES 2016; 7:mi7050083. [PMID: 30404259 PMCID: PMC6190260 DOI: 10.3390/mi7050083] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2016] [Revised: 04/22/2016] [Accepted: 04/26/2016] [Indexed: 11/17/2022]
Abstract
In this study, we developed a method for fabricating a microfluidic device with integrated large-scale all-glass valves and constructed an actuator system to control each of the valves on the device. Such a microfluidic device has advantages that allow its use in various fields, including physical, chemical, and biochemical analyses and syntheses. However, it is inefficient and difficult to integrate the large-scale all-glass valves in a microfluidic device using conventional glass fabrication methods, especially for the through-hole fabrication step. Therefore, we have developed a fabrication method for the large-scale integration of all-glass valves in a microfluidic device that contains 110 individually controllable diaphragm valve units on a 30 mm × 70 mm glass slide. This prototype device was fabricated by first sandwiching a 0.4-mm-thick glass slide that contained 110 1.5-mm-diameter shallow chambers, each with two 50-μm-diameter through-holes, between an ultra-thin glass sheet (4 μm thick) and another 0.7-mm-thick glass slide that contained etched channels. After the fusion bonding of these three layers, the large-scale microfluidic device was obtained with integrated all-glass valves consisting of 110 individual diaphragm valve units. We demonstrated its use as a pump capable of generating a flow rate of approximately 0.06–5.33 μL/min. The maximum frequency of flow switching was approximately 12 Hz.
Collapse
|
43
|
A Bio-Manipulation Method Based on the Hydrodynamic Force of Multiple Microfluidic Streams. JOURNAL OF ROBOTICS AND MECHATRONICS 2013. [DOI: 10.20965/jrm.2013.p0611] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper proposes a multiple microfluidic streambased manipulation (MMSM) system for bio-objects. It uses micro hydrodynamics and lab on chip (LOC) technology. Our method can implement the functions of micro manipulation and micro assembly of bio-objects in an open space without contact. Compared to other conventional bio-micro-manipulation and assembly methods, this system manipulates micro objects by controlling multiple microfluidic streams onto them from various directions. The advantages of this method are that it performs open space, multifunction, multi-scale, multi-degree-of-freedom, and non-invasive 3D manipulation. These microfluidic streams are generated simultaneously from multiple orifices. By regulating the parameters of the microfluidic stream, such as the position and number of operating orifices and the flow rate, the direction and velocity of the object can be controlled. To verify this principle, we design an open-space fluidic system for on-chip manipulation and calculated velocity and direction of the microfluidic stream using CFD simulation. Then the prototype microchip with an array of nine orifices is fabricated from glass. In experiments, demonstrations of rectilinear motion of a single cell andmicro particle are observed. The results presented in this paper show that this MMSM is capable of biomicromanipulation and micro assembly of bio-objects.
Collapse
|