1
|
Development of A Lateral Flow Highway: Ultra-Rapid Multitracking Immunosensor for Cardiac Markers. SENSORS 2019; 19:s19245494. [PMID: 31842479 PMCID: PMC6970229 DOI: 10.3390/s19245494] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 12/07/2019] [Accepted: 12/10/2019] [Indexed: 01/03/2023]
Abstract
The integration of several controlled parameters within a single test system is experiencing increased demand. However, multiplexed test systems typically require complex manufacturing. Here, we describe a multiplexed immunochromatographic assay that incorporates a conventional nitrocellulose membrane, which is used together with microspot printing, to construct adjacent microfluidic "tracks" for multiplexed detection. The 1 mm distance between tracks allows for the detection of up to four different analytes. The following reagents are applied in separate zones: (a) gold nanoparticle conjugates with antibodies against each analyte, (b) other antibodies against each analyte, and (c) antispecies antibodies. The immersion of the test strip in the sample initiates the lateral flow, during which reagents of different specificities move along their tracks without track erosion or reagent mixing. An essential advantage of the proposed assay is its extreme rapidity (1-1.5 min compared with 10 min for common test strips). This assay format was applied to the detection of cardiac and inflammatory markers (myoglobin, D-dimer, and C-reactive protein) in human blood, and was characterized by high reproducibility (8%-15% coefficient of variation) with stored working ranges of conventional tests. The universal character of the proposed approach will facilitate its use for various analytes.
Collapse
|
2
|
Muskox myoglobin: purification, characterization and kinetics studies compared with cattle and water buffalo myoglobins. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2019; 99:6278-6286. [PMID: 31259416 DOI: 10.1002/jsfa.9901] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 06/21/2019] [Accepted: 06/26/2019] [Indexed: 06/09/2023]
Abstract
BACKGROUND The Arctic muskox has economic potential as an alternative meat species and is becoming increasingly popular. The present study aimed to determine the primary structure and pseudoperoxidase activity of muskox myoglobin (Mb) compared to cattle and water buffalo myoglobins. RESULTS The primary structure of muskox Mb was determined via a matrix-assisted laser desorption ionization-time of flight mass spectrometry-based mapping approach using the sheep Mb as a reference sequence. The muskox Mb consists of 153 amino acid residues and shows 100% identity with sheep Mb, whereas 98.69% and 97.38% identity is found with cattle and water buffalo Mbs, respectively. Muskox Mb has an autoxidation rate (MetMb formation) higher than both cattle and water buffalo Mbs at pH 7.2 (37 °C). Moreover, its pseudoperoxidase activity is higher than both cattle and water buffalo Mbs at pH 7.4 (physiological pH), whereas it is slightly lower than cattle Mb and higher than water buffalo at a lower pH (5.8), corresponding to the conditions in meat. CONCLUSION For the first time, the present study reports the purification of myoglobin from muskoxen and, furthermore, a comparative study is conducted on autoxidation and pseudoperoxidase activity with respect to cattle and water buffalo Mbs at both physiological and acid pH. Overall, the results of the current research provide novel information for future studies useful to the meat industry when considering the importance of myoglobin as a principal pigment in meat colour stability. © 2019 Society of Chemical Industry.
Collapse
|
3
|
A Multi-Region Magnetoimpedance-Based Bio-Analytical System for Ultrasensitive Simultaneous Determination of Cardiac Biomarkers Myoglobin and C-Reactive Protein. SENSORS (BASEL, SWITZERLAND) 2018; 18:E1765. [PMID: 29857573 PMCID: PMC6022111 DOI: 10.3390/s18061765] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 05/26/2018] [Accepted: 05/28/2018] [Indexed: 12/12/2022]
Abstract
Cardiac biomarkers (CBs) are substances that appear in the blood when the heart is damaged or stressed. Measurements of the level of CBs can be used in course of diagnostics or monitoring the state of the health of group risk persons. A multi-region bio-analytical system (MRBAS) based on magnetoimpedance (MI) changes was proposed for ultrasensitive simultaneous detection of CBs myoglobin (Mb) and C-reactive protein (CRP). The microfluidic device was designed and developed using standard microfabrication techniques for their usage in different regions, which were pre-modified with specific antibody for specified detection. Mb and CRP antigens labels attached to commercial Dynabeads with selected concentrations were trapped in different detection regions. The MI response of the triple sensitive element was carefully evaluated in initial state and in the presence of biomarkers. The results showed that the MI-based bio-sensing system had high selectivity and sensitivity for detection of CBs. Compared with the control region, ultrasensitive detections of CRP and Mb were accomplished with the detection limits of 1.0 pg/mL and 0.1 pg/mL, respectively. The linear detection range contained low concentration detection area and high concentration detection area, which were 1 pg/mL⁻10 ng/mL, 10⁻100 ng/mL for CRP, and 0.1 pg/mL⁻1 ng/mL, 1 n/mL⁻80 ng/mL for Mb. The measurement technique presented here provides a new methodology for multi-target biomolecules rapid testing.
Collapse
|
4
|
Using an FPLC to promote active learning of the principles of protein structure and purification. BIOCHEMISTRY AND MOLECULAR BIOLOGY EDUCATION : A BIMONTHLY PUBLICATION OF THE INTERNATIONAL UNION OF BIOCHEMISTRY AND MOLECULAR BIOLOGY 2017; 45:60-68. [PMID: 27229266 DOI: 10.1002/bmb.20980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Revised: 03/23/2016] [Accepted: 04/12/2016] [Indexed: 06/05/2023]
Abstract
The concepts of protein purification are often taught in undergraduate biology and biochemistry lectures and reinforced during laboratory exercises; however, very few reported activities allow students to directly gain experience using modern protein purification instruments, such as Fast Protein Liquid Chromatography (FPLC). This laboratory exercise uses size exclusion chromatography (SEC) and ion exchange (IEX) chromatography to separate a mixture of four different proteins. Students use an SEC chromatogram and corresponding SDS-PAGE gel to understand how protein conformations change under different conditions (i.e. native and non-native). Students explore strategies to separate co-eluting proteins by IEX chromatography. Using either cation or anion exchange, one protein is bound to the column while the other is collected in the flow-through. In this exercise, undergraduate students gain hands-on experience with experimental design, buffer and sample preparation, and implementation of instrumentation that is commonly used by experienced researchers while learning and applying the fundamental concepts of protein structure, protein purification, and SDS-PAGE. © 2016 by The International Union of Biochemistry and Molecular Biology, 45(1):60-68, 2017.
Collapse
|
5
|
Myoglobin structure and function: A multiweek biochemistry laboratory project. BIOCHEMISTRY AND MOLECULAR BIOLOGY EDUCATION : A BIMONTHLY PUBLICATION OF THE INTERNATIONAL UNION OF BIOCHEMISTRY AND MOLECULAR BIOLOGY 2015; 43:181-8. [PMID: 25726810 DOI: 10.1002/bmb.20845] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Accepted: 11/02/2014] [Indexed: 05/25/2023]
Abstract
We have developed a multiweek laboratory project in which students isolate myoglobin and characterize its structure, function, and redox state. The important laboratory techniques covered in this project include size-exclusion chromatography, electrophoresis, spectrophotometric titration, and FTIR spectroscopy. Regarding protein structure, students work with computer modeling and visualization of myoglobin and its homologues, after which they spectroscopically characterize its thermal denaturation. Students also study protein function (ligand binding equilibrium) and are instructed on topics in data analysis (calibration curves, nonlinear vs. linear regression). This upper division biochemistry laboratory project is a challenging and rewarding one that not only exposes students to a wide variety of important biochemical laboratory techniques but also ties those techniques together to work with a single readily available and easily characterized protein, myoglobin.
Collapse
|
6
|
Synthesis and characterization of reduced graphene oxide supported gold nanoparticles-poly(pyrrole-co-pyrrolepropylic acid) nanocomposite-based electrochemical biosensor. Appl Biochem Biotechnol 2014; 174:911-25. [PMID: 24928550 DOI: 10.1007/s12010-014-0997-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Accepted: 05/22/2014] [Indexed: 11/26/2022]
Abstract
A conducting poly(pyrrole-co-pyrrolepropylic acid) copolymer nanocomposite film (AuNP-PPy-PPa) incorporating gold nanoparticles (AuNP) was electrochemically grown using a single step procedure over electrochemically reduced graphene oxide (RGO) flakes deposited on a silane-modified indium-tin-oxide (ITO) glass plate. The RGO support base provided excellent mechanical and chemical stability to the polymer nanocomposite matrix. The porous nanostructure of AuNP-PPy-PPa/RGO provided a huge accessible area to disperse AuNP, and it avoided metallic agglomeration within the polymer matrix. The AuNP-PPy-PPa/RGO was characterized by high-resolution transmission electron microscopy (HRTEM), contact angle measurements, Fourier transform infrared spectroscopy (FTIR), and electrochemical techniques. The pendant carboxyl group of AuNP-PPy-PPa/RGO was covalently bonded with myoglobin protein antibody, Ab-Mb, for the construction of a bioelectrode. Electrochemical impedance spectroscopy technique was used for the characterization of the bioelectrode and as an impedimetric biosensor for the detection of human cardiac biomarker, Ag-cMb. The bioelectrode exhibited a linear impedimetric response to Ag-cMb in the range of 10 ng mL(-1) to 1 μg mL(-1), in phosphate-buffered solution (PBS) (pH 7.4, 0.1 M KCl) with a sensitivity of 92.13 Ω cm(2) per decade.
Collapse
|
7
|
Kinetic modelling of haemodialysis removal of myoglobin in rhabdomyolysis patients. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2014; 114:e29-e38. [PMID: 24008249 DOI: 10.1016/j.cmpb.2013.07.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 07/09/2013] [Accepted: 07/22/2013] [Indexed: 06/02/2023]
Abstract
An extended two compartment model is proposed to describe the dynamics of myoglobin in rhabdomyolysis patients undergoing dialysis. Before using clinical data to estimate the model's unknown parameters, structural identifiability analysis was performed to determine the parameters uniqueness given certain clinical observations. A Taylor series expansion method was implemented which found that the model was structurally globally/uniquely identifiable for both on- and off-dialysis phases. The fitted model was then used in a predictive capacity showing that the use of Theralite high cut-off (HCO) or HCO 1100 dialyser gave a significant reduction in myoglobin renal exposure compared to standard haemodialysis (HD).
Collapse
|
8
|
Modulation of the intermolecular interaction of myoglobin by removal of the heme. JOURNAL OF SYNCHROTRON RADIATION 2013; 20:919-22. [PMID: 24121340 PMCID: PMC3795556 DOI: 10.1107/s0909049513022772] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 08/13/2013] [Indexed: 06/02/2023]
Abstract
Toward understanding intermolecular interactions governing self-association of proteins, the present study investigated a model protein, myoglobin, using a small-angle X-ray scattering technique. It has been known that removal of the heme makes myoglobin aggregation-prone. The interparticle interferences of the holomyoglobin and the apomyoglobin were compared in terms of the structure factor. Analysis of the structure factor using a model potential of Derjaguin-Laudau-Verwey-Overbeek (DLVO) suggests that the intermolecular interaction potential of apomyoglobin is more attractive than that of holomyoglobin at short range from the protein molecule.
Collapse
|
9
|
A multifunctional microfluidic droplet-array chip for analysis by electrospray ionization mass spectrometry. LAB ON A CHIP 2013; 13:1876-1882. [PMID: 23525283 DOI: 10.1039/c3lc00063j] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper describes a multifunctional semi-closed droplet-array chip coupled with electrospray ionization mass spectrometry (ESI-MS) detection for multiple sample pretreatment and analysis. A novel interfacing method for coupling droplet system with ESI-MS was proposed using a sampling probe-two-dimensional (2D) droplet-array strategy. The 2D droplet-array system was composed of an 8 × 8 microwell array chip for droplet storage and a layer of oil covering the droplets served as a "virtual wall" to avoid droplet evaporation or cross-contamination. An L-shaped capillary was adopted as the interface of the droplet array and ESI-MS, using its inlet end as a sampling probe for droplets and its outlet with a tip size of ~20 μm as an electrospray emitter, without the need for any droplet extraction device. The droplet analysis was performed by moving the droplet-array chip to allow the capillary sampling probe to sequentially enter into the droplets through the oil and introduce the sample solution into the capillary emitter for MS detection. The MS analysis time for each droplet sample was 40 s with a sample consumption of ca. 13 nL. A good repeatability of 5.7% (RSD, n = 9) was obtained for 10(-6) M reserpine droplet analysis. The uses of the semi-closed 2D droplet array and off-line interfacing mode provide the system with the substantial flexibility and controllability in droplet indexing, multi-step manipulating, and on-demand sampling for MS analysis. We applied the present system in multi-step pretreatment and identification of small amounts of proteomic samples of myoglobin and cytochrome C, including in-droplet protein reduction, alkylation, digestion, and purification based on solid-phase extraction, matrix modification, sample droplet introduction under flow injection mode, and ESI-MS detection.
Collapse
|
10
|
Proteolysis in microfluidic droplets: an approach to interface protein separation and peptide mass spectrometry. LAB ON A CHIP 2012; 12:2625-9. [PMID: 22695710 DOI: 10.1039/c2lc40206h] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
A versatile microreactor protocol based on microfluidic droplets has been developed for on-line protein digestion. Proteins separated by liquid chromatography are fractionated in water-in-oil droplets and digested in sequence. The microfluidic reactor acts also as an electrospray ionization emitter for mass spectrometry analysis of the peptides produced in the individual droplets. Each droplet is an enzymatic micro-reaction unit with efficient proteolysis due to rapid mixing, enhanced mass transfer and automated handling. This droplet approach eliminates sample loss, cross-contamination, non-specific absorption and memory effect. A protein mixture was successfully identified using the droplet-based micro-reactor as interface between reverse phase liquid chromatography and mass spectrometry.
Collapse
|
11
|
Toroidal coil chromatography: the effect of scale-up and "g" field on stage efficiency. J Chromatogr A 2011; 1218:6144-7. [PMID: 21227439 PMCID: PMC3223526 DOI: 10.1016/j.chroma.2010.12.090] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2010] [Revised: 12/17/2010] [Accepted: 12/21/2010] [Indexed: 12/04/2022]
Abstract
Selected test results have been taken from various publications and resolution and stage efficiency measured using an established model. All experiments used the same sample and, where possible, the same sample loading. The results show that stage mixing efficiencies have increased from 1.1% in 1998 to greater than 25% in the latest scaled-up version of a Toroidal coil chromatography (TCC) instrument working at 240 g.
Collapse
|
12
|
The effect of different atmospheric conditions on the changes in myoglobin and colour of refrigerated Eastern little tuna (Euthynnus affinis) muscle. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2011; 91:1103-1110. [PMID: 21328356 DOI: 10.1002/jsfa.4290] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2010] [Revised: 10/01/2010] [Accepted: 11/26/2010] [Indexed: 05/30/2023]
Abstract
BACKGROUND Oxidation of myoglobin is responsible for the undesirable appearance and loss in acceptability of fish and fish products. The retardation of such a change by a modification of the surrounding atmosphere would be a means to maintain the quality of fish during the refrigerated storage. RESULTS The changes in oxymyoglobin and metmyoglobin from dark muscle of Eastern little tuna (Euthynnus affinis) as affected by different atmospheric systems (closed system, opened system and flushed oxygen system) were determined. A saturated oxygen atmosphere more likely weakened the haem-globin complex, especially as the exposure time increased. Autoxidation of the oxy form proceeded rapidly in the presence of oxygen with the concomitant formation of the met form. When the oxygen was excluded, oxidation of oxymyoglobin was retarded. With flushed oxygen and increasing exposure time, conformational changes of globin occurred, mainly associated with protein oxidation. Generally, oxymyoglobin was more susceptible to oxidation and conformational change than did metmyoglobin. After keeping the samples at 4 °C for 3 days, dark muscle of tuna fillet kept in vacuum packaging had a slight decrease in redness and it was still acceptable. The fillets stored in exposed air or packed in 100% O(2) atmosphere turned brown, most likely due to myoglobin oxidation. CONCLUSION The oxygen level of the packaging atmosphere had a profound impact on myoglobin alteration, which was governed by the forms of myoglobin.
Collapse
|
13
|
Abstract
A novel approach to molecular separations is investigated using a technique termed droplet-based isoelectric focusing. Drops are manipulated discretely on a superhydrophobic surface, subjected to low voltages for isoelectric focusing, and split-resulting in a preparative separation. A universal indicator dye demonstrates the generation of stable, reversible pH gradients (3-10) in ampholyte buffers, and these gradients lead to protein focusing within the drop length. Focusing was visually characterized, spectroscopically verified, and assessed quantitatively by noninvasive light scattering measurements. It was found to correlate with a quantitative model based on 1D steady-state theory. This work illustrates that molecular separations can be deployed within a single open drop, and the differential fractions can be separated into new discrete liquid elements.
Collapse
|
14
|
Surfactant-bound monolithic columns for separation of proteins in capillary high performance liquid chromatography. J Chromatogr A 2010; 1217:530-9. [PMID: 20031139 PMCID: PMC3098612 DOI: 10.1016/j.chroma.2009.11.082] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2009] [Accepted: 11/25/2009] [Indexed: 10/20/2022]
Abstract
A surfactant-bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA-EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e., morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase.
Collapse
|
15
|
Direct analysis of reversed-phase high-performance thin layer chromatography separated tryptic protein digests using a liquid microjunction surface sampling probe/electrospray ionization mass spectrometry system. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2010; 16:21-33. [PMID: 20065522 DOI: 10.1255/ejms.1041] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The sampling, ionization and detection of tryptic peptides separated in one-dimension on reversed-phase high-performance thin layer chromatography (HPTLC) plates was performed using liquid microjunction surface sampling probe electrospray ionization mass spectrometry. Tryptic digests of five proteins [cytochrome c, myoglobin, beta-casein, lysozyme and bovine serum albumin (BSA)] were spotted on reversed phase HPTLC RP-8 F254s and HPTLC RP-18 F254s plates. The plates were then developed using 70/30 methanol/water with 0.1M ammonium acetate. A dual purpose extraction/electrospray solution containing 70/30/0.1 water/methanol/formic acid was infused through the sampling probe during analysis of the developed lanes. Both full scan mass spectra and data dependent tandem mass spectra were acquired for each development lane to detect and verify the peptide distributions. Data dependent tandem mass spectra provided both protein identification and sequence coverage information. Highest sequence coverages were achieved for cytochrome c and myoglobin (62.5% and 58.3%, respectively) on reversed phase RP-8 plates. While the tryptic peptides were separated enough for identification, the peptide bands did show some overlap with most peptides located in the lower half of the development lane. Proteins whose peptides were more separated gave higher sequence coverage. Larger proteins such as beta-casein and BSA which were spotted in lower relative amounts gave much lower sequence coverage than the smaller proteins.
Collapse
MESH Headings
- Amino Acid Sequence
- Animals
- Caseins/analysis
- Caseins/isolation & purification
- Cattle
- Chickens
- Chromatography, High Pressure Liquid/instrumentation
- Chromatography, High Pressure Liquid/methods
- Chromatography, Reverse-Phase/instrumentation
- Chromatography, Reverse-Phase/methods
- Chromatography, Thin Layer/instrumentation
- Chromatography, Thin Layer/methods
- Cytochromes c/analysis
- Cytochromes c/isolation & purification
- Equipment Design
- Horses
- Molecular Sequence Data
- Muramidase/analysis
- Muramidase/isolation & purification
- Myoglobin/analysis
- Myoglobin/isolation & purification
- Proteins/analysis
- Proteins/isolation & purification
- Serum Albumin, Bovine/analysis
- Serum Albumin, Bovine/isolation & purification
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
Collapse
|
16
|
Mass spectrometric characterization and redox instability of turkey and chicken myoglobins as induced by unsaturated aldehydes. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2009; 57:8668-8676. [PMID: 19711951 DOI: 10.1021/jf902705q] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Turkey and chicken myoglobins (Mbs) were isolated, purified, and characterized using electrospray ionization mass spectrometry (ESI-MS), and the effect of unsaturated aldehydes (nonenal and hexenal) on their redox stability was investigated in vitro. The deconvoluted spectra from ESI-MS exhibited a molecular mass of 17291 Da for both turkey and chicken Mbs. Significant homogeneity in the fragmentation pattern of both Mbs was indicated by ESI-MS/MS. Both turkey and chicken oxymyoglobins (OxyMbs) were more prone to oxidation at pH 5.8 than at pH 7.4. Metmyoglobin formation was greater in the presence of unsaturated aldehydes than controls (P < 0.05). The results demonstrated that both turkey and chicken Mbs have identical molecular mass and that the effects of alpha,beta-unsaturated aldehydes on their redox stability are consistent with those of mammalian livestock Mbs.
Collapse
|
17
|
Abstract
The removal of product variants that form during downstream processing remains a challenge in the purification of recombinant therapeutic proteins. We examined the feasibility of separating variants with slightly different net charge using high-performance membrane ultrafiltration. A myoglobin variant was formed by reaction of the lysine epsilon-amino group with succinic anhydride. Sieving data were obtained over a range of solution conditions using commercial polyethersulfone ultrafiltration membranes. Maximum selectivity of about 7-fold was obtained at very low conductivity due to the strong electrostatic repulsion of the more negatively charged variant. Protein separations were performed by diafiltration. A two-stage process generated solutions of the normal myoglobin (in the permeate) and the charge variant (in the retentate), both at greater than 9-fold purification and 90% yield. These results provide the first demonstration that membrane systems can be used to separate proteins that differ by only a single charged amino acid residue.
Collapse
|
18
|
In-line system containing porous polymer monoliths for protein digestion with immobilized pepsin, peptide preconcentration and nano-liquid chromatography separation coupled to electrospray ionization mass spectroscopy. J Chromatogr A 2008; 1188:88-96. [PMID: 18342870 PMCID: PMC2435401 DOI: 10.1016/j.chroma.2008.02.075] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2007] [Revised: 02/10/2008] [Accepted: 02/15/2008] [Indexed: 10/22/2022]
Abstract
The use of two different monoliths located in capillaries for on-line protein digestion, preconcentration of peptides and their separation has been demonstrated. The first monolith was used as support for covalent immobilization of pepsin. This monolith with well-defined porous properties was prepared by in situ copolymerization of 2-vinyl-4,4-dimethylazlactone and ethylene dimethacrylate. The second, poly(lauryl methacrylate-co-ethylene dimethacrylate) monolith with a different porous structure served for the preconcentration of peptides from the digest and their separation in reversed-phase liquid chromatography mode. The top of the separation capillary was used as a preconcentrator, thus enabling the digestion of very dilute solutions of proteins in the bioreactor and increasing the sensitivity of the mass spectrometric detection of the peptides using a time-of-flight mass spectrometer with electrospray ionization. Myoglobin, albumin, and hemoglobin were digested to demonstrate feasibility of the concept of using the two monoliths in-line. Successive protein injections confirmed both the repeatability of the results and the ability to reuse the bioreactor for at least 20 digestions.
Collapse
|
19
|
Gel-free sample preparation for the nanoscale LC-MS/MS analysis and identification of low-nanogram protein samples. J Sep Sci 2007; 30:2210-6. [PMID: 17763504 DOI: 10.1002/jssc.200700192] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Protein identification at the low nanogram level could in principle be obtained by most nanoscale LC-MS/MS systems. Nevertheless, the complex sample preparation procedures generally required in biological applications, and the consequent high risk of sample losses, very often hamper practical achievement of such low levels. In fact, the minimal amount of protein required for the identification from a gel band or spot, in general, largely exceeds the theoretical limit of identification reachable by nanoscale LC-MS/MS systems. A method for the identification of low levels of purified proteins, allowing limits of identification down to 1 ng when using standard bore, 75 microm id nanoscale LC-MS/MS systems is here reported. The method comprises an offline two-step sample cleanup, subsequent to protein digestion, which is designed to minimize sample losses, allows high flexibility in the choice of digestion conditions and delivers a highly purified peptide mixture even from "real world" digestion conditions, thus allowing the subsequent nanoscale LC-MS/MS analysis to be performed in automated, unattended operation for long series. The method can be applied to the characterization of low levels of affinity purified proteins.
Collapse
|
20
|
Gradient elution separation and peak capacity of columns packed with porous shell particles. J Chromatogr A 2007; 1163:203-11. [PMID: 17632112 DOI: 10.1016/j.chroma.2007.06.046] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2007] [Revised: 06/13/2007] [Accepted: 06/18/2007] [Indexed: 10/23/2022]
Abstract
The separation of the tryptic digests of myoglobin and bovine serum albumin were carried out in the gradient elution mode, using water, acetonitrile and TFA as the mobile phase components and columns packed with a new type of shell particles, Halo C(18). These particles give very high efficiencies, characterized with an unusually low eddy diffusion contribution and a small mass transfer contribution. However, because the molecular diffusivities of the peptides in the digest are small, the mobile phase velocity corresponding to the optimum velocity for maximum efficiency is also small, of the order of 0.3 mm/s. The gradient slopes also must be small. Peak capacities of 400 were achieved, with analysis time of the order of an hour.
Collapse
|
21
|
Capillary Electrophoresis as a Second Dimension to Isoelectric Focusing for Peptide Separation. Anal Chem 2007; 79:5949-55. [PMID: 17583968 DOI: 10.1021/ac070493r] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Capillary zone electrophoresis and carrier ampholytes based capillary electrophoresis have been used as a second separation step to Off-Gel isoelectric focusing for the analysis of complex peptide mixtures. A tryptic digest of four proteins (bovine serum albumin, beta-lactoglobulin, horse myoglobin, cytochrome c) has been chosen as a peptide test mixture. After assessment of different modes of capillary electrophoresis as a second dimension to Off-Gel isoelectric focusing, the optimized two-dimensional platforms provide a degree of orthogonality comparable to state-of-the-art multidimensional liquid chromatography systems as well as a practical peak capacity above 700.
Collapse
|
22
|
Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures. Anal Chem 2007; 78:1697-706. [PMID: 16503625 DOI: 10.1021/ac0518304] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The effect that elevated pressure used in ultrahigh-pressure liquid chromatography (UHPLC) has on protein recovery was investigated. Specifically, protein carryover ("ghosting") and recovery were examined. Four model proteins (ribonuclease A, ovalbumin, myoglobin, BSA) were separated by gradient RPLC at both conventional (160 bar) and ultrahigh pressures (>1500 bar). A custom gradient UHPLC system was used to generate conventional pressures on 5-microm diameter reversed-phase supports and ultrahigh pressures on identical 1.4-microm supports. The results indicate that, by increasing the pressure, protein carryover from run to run is reduced and in some cases eliminated above a certain threshold pressure for the model proteins studied. Further work indicates that recovery was enhanced for each of the proteins studied, even approaching 100% for certain proteins.
Collapse
|
23
|
Dynamics of equilibrium structural fluctuations of apomyoglobin measured by fluorescence correlation spectroscopy. Proc Natl Acad Sci U S A 2007; 104:10459-64. [PMID: 17556539 PMCID: PMC1965535 DOI: 10.1073/pnas.0704073104] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
The spectra of equilibrium chain conformation fluctuations of apomyoglobin (apoMb) as a function of folding, from the acid-denatured state at pH 2.6 through the stable molten globule state pH approximately 4.1 to the folded state at pH 6.3, are reported, as measured by fluorescence correlation spectroscopy. The conformational fluctuations, which are detected by quenching of an N-terminal fluorescent label by contact with various amino acids, can be represented by superpositions of decaying exponentials with time scales ranging from approximately 3 to approximately 200 micros. Both the time scales and amplitudes of the fluctuations increase with the degree of acid denaturation, with principal shifts associated with the transition across the molten globule state. Measurements of the diffusion of apoMb confirm theoretical values showing a approximately 40% increase in the hydrodynamic radius upon acid denaturation. This study uses the model protein apoMb to illustrate the complex scope of folding associated structural dynamics.
Collapse
|
24
|
Protein separation and enrichment by counter-current chromatography using reverse micelle solvent systems. J Chromatogr A 2007; 1151:164-8. [PMID: 17289061 DOI: 10.1016/j.chroma.2007.01.079] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2006] [Revised: 01/10/2007] [Accepted: 01/19/2007] [Indexed: 11/20/2022]
Abstract
A protein mixture consisting of myoglobin, cytochrome c, and lysozyme was separated by high-speed counter-current chromatography using a two-phase aqueous/reverse micelle-containing organic solvent system. About 50% stationary phase retention ratio was obtained in most chromatographic experiments. Separations were manipulated mainly by pH gradients that controlled the electrostatic interactions between the protein molecules and reverse micelles. Separations were further improved by incorporating an ionic strength gradient along with the pH gradient. Control of ionic strength in the aqueous solution helped fine-tune protein partitioning between the stationary and mobile phases. Although non-specific protein interactions affected baseline resolution, recovery of cytochrome c and lysozyme reached 90% and 82%. Furthermore, concentration or enrichment of these two proteins was achieved from a large-volume sample load. This technique can potentially be employed in the recovery and enrichment of proteins from large-volume aqueous solutions.
Collapse
|
25
|
Diffusive motions control the folding and unfolding kinetics of the apomyoglobin pH 4 molten globule intermediate. Biochemistry 2007; 46:4379-89. [PMID: 17367166 DOI: 10.1021/bi602574x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The sperm whale apomyoglobin pH 4 folding intermediate exists in two forms, Ia and Ib, that mimic transient kinetic intermediates in the folding of the native protein at pH 6. To characterize the nature of the kinetic barrier that controls the formation of the earliest intermediate Ia, we have investigated the effects of small viscogenic cosolvents on its folding and unfolding kinetics. The kinetics are measurable by stopped-flow fluorescence and follow a cooperative two-state model in the absence and presence of cosolvents. Small cosolvents stabilize Ia, but, by applying the isostability test to separate the viscogenic effect of the cosolvent from its stabilizing effect, we found that, in both folding and unfolding conditions, the apparent rate constant decreases when solvent viscosity increases. The unitary inverse dependence of the apparent rate constant on solvent viscosity indicates a diffusion-controlled reaction. This result is consistent with the hypothesis that folding of the apomyoglobin pH 4 intermediate obeys a diffusion-collision model. Additionally, the temperature dependence of the reaction rate at constant viscosity indicates that the formation of Ia is also controlled by an energy barrier. Linear free energy relationships show that the transition state of the U <==> Ia reaction is compact and buries 45% of the surface area that is buried in native apomyoglobin. We conclude that the transition state of the U <==> Ia reaction resembles that for the formation of native proteins; namely, it is dry and its compactness is closer to that of the folded (Ia) form than of the unfolded form.
Collapse
|
26
|
Experimental characterization and modelling of analytical monolithic column. ACTA ACUST UNITED AC 2007; 70:95-105. [PMID: 17123626 DOI: 10.1016/j.jbbm.2006.10.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2006] [Revised: 09/21/2006] [Accepted: 10/10/2006] [Indexed: 11/28/2022]
Abstract
Hydrodynamics, equilibrium and kinetics of adsorption in a silica-based monolithic column Chromolith Performance RP-18e (Merck KgaA, Germany) have been studied. The column permeability was calculated according to the Darcy law for laminar flow. The efficiency of the monolithic column was characterized through the height equivalent to a theoretical plate (HETP) for myoglobin, phenol and progesterone. The 2-D single channel mathematical model has been applied to describe the adsorption dynamics. Parabolic velocity profile, axial and radial diffusion in the monolith channel, linear driving force model for the mass transfer in the monolith channel skeleton wall and linear adsorption equilibrium were assumed. The mathematical model gives good prediction of the experimental elution peaks.
Collapse
|
27
|
Application of central composite design to the optimisation of aqueous two-phase extraction of human antibodies. J Chromatogr A 2007; 1141:50-60. [PMID: 17196214 DOI: 10.1016/j.chroma.2006.11.075] [Citation(s) in RCA: 164] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2006] [Revised: 11/20/2006] [Accepted: 11/24/2006] [Indexed: 11/24/2022]
Abstract
The partition of human antibodies in aqueous two-phase systems (ATPSs) of polyethylene glycol (PEG) and phosphate was systematically studied using first pure proteins systems and then an artificial mixture of proteins containing 1mg/ml human immunoglobulin G (IgG), 10mg/ml serum albumin and 2mg/ml myoglobin. Preliminary results obtained using pure proteins systems indicated that the PEG molecular weight and concentration, the pH value and the salts concentration had a pronounced effect on the partitioning behaviour of all proteins. For high ionic strengths and pH values higher than the isoelectric point (pI) of the contaminant proteins, IgG could be selectively recovered on the top phase. According to these results, a face centred composite design was performed in order to optimise the purification of IgG from the mixture of proteins. The optimal conditions for the isolation of IgG were observed for high concentrations of NaCl and low concentrations of both phase forming components. The best purification was achieved using an ATPS containing 8% (w/w) PEG 3350, 10% (w/w) phosphate pH 6 and 15% (w/w) NaCl. A recovery yield of 101+/-7%, a purity of 99+/-0% and a yield of native IgG of 97+/-4% were obtained. Back extraction studies of IgG to a new phosphate phase were performed and higher yields were obtained using 10% phosphate buffer at pH 6. The total extraction yield was 76% and the purity 100%.
Collapse
|
28
|
Stability and repeatability of capillary columns based on porous monoliths of poly(butyl methacrylate-co-ethylene dimethacrylate). J Chromatogr A 2007; 1140:140-6. [PMID: 17182044 PMCID: PMC2680358 DOI: 10.1016/j.chroma.2006.11.079] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2006] [Revised: 11/17/2006] [Accepted: 11/24/2006] [Indexed: 10/23/2022]
Abstract
Monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) capillary columns have been prepared via either thermally or photochemically initiated polymerization of the corresponding monomers and the repeatability of their preparation has been explored. Three separate batches of 5 columns each were prepared using thermal and photochemical initiation for a total of 30 columns. All 30 capillary columns were tested in liquid chromatography-electrospray ionisation mass spectrometry mode for the separation of a model mixture of three proteins--ribonuclease A, cytochrome c and myoglobin. Excellent repeatability of retention times was observed for the proteins as evidenced by relative standard deviation (RSD) values of less than 1.5%. Somewhat broader variations with RSD values of up to 10% were observed for the pressure drop in the columns. The stability of retention times was also monitored using a single monolithic column and no significant shifts in either retention times or back pressure was observed in a series of almost 2200 consecutive protein separations.
Collapse
|
29
|
Characterization and kinetics studies of water buffalo (Bubalus bubalis) myoglobin. Comp Biochem Physiol B Biochem Mol Biol 2006; 145:230-8. [PMID: 16959515 DOI: 10.1016/j.cbpb.2006.07.006] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2006] [Revised: 07/18/2006] [Accepted: 07/20/2006] [Indexed: 10/24/2022]
Abstract
The colour of buffalo (Bubalus bubalis L.) meat is darker than bovine meat. Since meat colour depends on the concentration of myoglobin (Mb) and its oxidation state, we have determined the main structural and functional properties of buffalo Mb. Buffalo Mb was purified from longissimus dorsi muscles and its molecular mass determined by ESI Q-TOF mass spectrometry. The molecular mass 17,034.50 was 86.20 Da higher than the bovine Mb. This was confirmed by analysing its primary structure, using a combined approach based on Edman degradation and MALDI-TOF mass spectrometry. Comparing the amino acid sequences of both Mbs, we found three amino acid differences out of 153 amino acid residues. One is a conservative substitution (D(bov)141E(buf)), and the other two (A(bov)19T(buf) and A(bov)117D(buf)) are nonconservative. These amino acid substitutions are unlikely to cause structural changes because they are located far from the heme binding pocket, as revealed by the 3D structure of buffalo Mb elaborated by homology modelling. Stability analyses show no difference with the bovine Mb for helix E and only minor differences in the stability values for helices A and G. Moreover, autoxidation rates of purified buffalo and bovine myoglobins at 37 degrees C, pH 7.2, were almost identical, 0.052+/-0.001 h(-1) and 0.054+/-0.002 h(-1), respectively, as were their oxygen-binding Kd values, 3.7+/-0.1 microM and 3.5+/-0.1 microM, respectively. The percent of MetMb values were almost identical. The results presented here suggest that the darker buffalo meat depends on factors other than the oxidation rate of its Mb, as, for example, the Mb content (0.393+/-0.005 g/100 g of tissue) and consequently MetMb, which are almost twice as high as bovine meat (Mb: 0.209+/-0.003 g/100 g of tissue).
Collapse
|
30
|
Capillary electrophoresis with a UV light-emitting diode source for chemical monitoring of native and derivatized fluorescent compounds. Electrophoresis 2006; 27:4052-9. [PMID: 16983640 DOI: 10.1002/elps.200600232] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We report the utilization of a high power UV light-emitting diode for fluorescence detection (UV-LED-IF) in CE separations. CE-UV-LED-IF allows analysis of a range of environmentally and biologically important compounds, including PAHs and biogenic amines, including neurotransmitters, amino acids, proteins, and peptides, that have been derivatized with UV-excited fluorogenic labels, e.g., o-phthalic dicarboxaldehyde/beta-mercaptoethanol (OPA/beta-ME). The 365 nm UV-LED was used as a stable, low cost source for detection of UV-excited fluorescent compounds. UV-LED-IF was used with both zonal CE separations and MEKC. Native fluorescence detection of PAHs was accomplished with detection limits ranging from 10 nM to 1.3 microM. Detection limits for OPA/beta-ME-labeled glutamic acid and aspartic acid were 11 and 10 nM, respectively, for off-line labeling, and 47 and 47 nM, respectively, for on-line labeling, comparable to UV-laser-based systems. Analysis of OPA/beta-ME-labeled proteins and peptides was performed with 28 and 47 nM detection limits for BSA and myoglobin, respectively.
Collapse
|
31
|
Effects of increased voltage on resolution in preparative isoelectric focusing of myoglobin varia. Electrophoresis 2006; 27:3325-31. [PMID: 16944464 DOI: 10.1002/elps.200500939] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
IEF is a powerful technique which separates proteins and other amphoteric solutes in a pH gradient according to their pI's. The current work evaluates the effect on resolution of increasing electric fields in a novel preparative, vortex-stabilized electrophoresis device. In shallow gradients spanning one pH unit, the variants of myoglobin were separated at applied voltages from 10 to 15 kV. Digital imaging of these separations indicated a 20% reduction in bandwidth and a 60% increase in resolution as the electric field strength is varied across this range. These results were confirmed by IEF-PAGE and ion-exchange chromatography.
Collapse
|
32
|
Two-dimensional capillary liquid chromatography: pH Gradient ion exchange and reversed phase chromatography for rapid separation of proteins. J Chromatogr A 2006; 1120:132-41. [PMID: 16516903 DOI: 10.1016/j.chroma.2006.02.031] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2005] [Revised: 01/24/2006] [Accepted: 02/14/2006] [Indexed: 11/18/2022]
Abstract
In the present work, an orthogonal two-dimensional (2D) capillary liquid chromatography (LC) method for fractionation and separation of proteins using wide range pH gradient ion exchange chromatography (IEC) in the first dimension and reversed phase (RP) in the second dimension, is demonstrated. In the first dimension a strong anion exchange (SAX) column subjected to a wide range (10.5-3.5) descending pH gradient was employed, while in the second dimension, a large pore (4,000 A) polystyrene-divinylbenzene (PS-DVB) RP analytical column was used for separation of the protein pH-fractions from the first dimension. The separation power of the off-line 2D method was demonstrated by fractionation and separation of human plasma proteins. Seventeen pH-fractions were manually collected and immediately separated in the second dimension using a column switching capillary RP-LC system. Totally, more than 200 protein peaks were observed in the RP chromatograms of the pH-fractions. On-line 2D analysis was performed for fractionation and separation of ten standard proteins. Two pH-fractions (basic and acidic) from the first dimension were trapped on PS-DVB RP trap columns prior to back-flushed elution onto the analytical RP column for fast separation of the proteins with UV/MS detection.
Collapse
|
33
|
Plastic microchip liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometry using monolithic columns. J Chromatogr A 2006; 1111:40-7. [PMID: 16480733 DOI: 10.1016/j.chroma.2006.01.105] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2005] [Revised: 01/10/2006] [Accepted: 01/24/2006] [Indexed: 10/25/2022]
Abstract
A prototype array of monolithic liquid chromatography (LC) columns was prepared in a plastic microfluidic device for the off-line interface with matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The microfluidic channels were fabricated on a cyclic olefin copolymer (COC) plate by hot embossing. An array of methacrylate monolithic columns was prepared in the microfluidic channels by UV-initiated polymerization. The deposition system employed a pulsed electric field to transfer the effluents from multiple columns directly onto MALDI targets with a non-contact deposition method reported by Ericson et al. [C. Ericson, Q.T. Phung, D.M. Horn, E.C. Peters, J.R. Fitchett, S.B. Ficarro, A.R. Salmon, L.M. Brill, A. Brock, Anal. Chem. 75 (2003) 2309]. To characterize the off-line interface of the multiple-channel microchip LC and the MALDI-MS for the analysis of peptide mixtures, the separation efficiency and reproducibility tests in each column were carried out by separating a peptide mixture from tryptic digested proteins and depositing the multiple effluents simultaneously on the MALDI target plate. Using a MALDI-TOF mass spectrometer with a mass accuracy of +/-1 Da for peptide assignments of digested bovine serum albumin (BSA), amino acid sequence coverage of around 59% was obtained for the microchip LC-MALDI-MS compared to 23% obtained by the MALDI-MS method without LC separation. In sensitivity tests for the detection of low abundance proteins in the presence of high concentration protein mixtures, as low as 10 fmol/mul (S/N = 10) of a spiked peptide in 1 microg of digested BSA could be detected. In the analysis of a mixture of three digested proteins (BSA, myoglobin, and cytochrome c), more than twice the amino acid sequence coverage was obtained for the microchip LC-MALDI-MS compared to MALDI-MS alone.
Collapse
|
34
|
In vitro expression and characterization of native apomyoglobin under low molecular crowding conditions. Protein Expr Purif 2006; 45:381-92. [PMID: 16169747 DOI: 10.1016/j.pep.2005.08.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2005] [Revised: 07/29/2005] [Accepted: 08/01/2005] [Indexed: 10/25/2022]
Abstract
The labile nature of membranes and organelles poses serious challenges to in situ biomolecule characterization in intact cells. Cell-free in vitro systems provide an alternative promising medium for the expression and characterization of protein conformation and function in a biochemical context that bears several similarities to the cellular environment. In addition, cell-free transcription-translation has recently emerged as a convenient method for protein selective isotope labeling, providing significant advantages for detailed NMR analysis. We report the cell-free expression of the model protein apomyoglobin (apoMb) in an Escherichia coli cell-free system and the effect of polyethylene glycol (PEG) on the expression yields. In contrast with in vivo protein production under control of the strong T7 promoter, apoMb is expressed in vitro in 100% soluble form. In-gel tryptic digestion followed by mass spectrometry were performed to confirm the protein identity. In order to probe the conformation of the newly expressed protein and investigate the feasibility of in situ structural analysis, high resolution protein characterization was carried out by 2D NMR spectroscopy. In vitro apoMb expression in a PEG-free environment is a convenient method for the production of soluble native-like protein under conditions amenable to selective isotopic labeling. Yields can be easily scaled-up by dialysis-assisted cell-free expression.
Collapse
|
35
|
Expanded bed adsorption/desorption of proteins with Streamline Direct CST I adsorbent. Biotechnol Bioeng 2006; 94:1155-63. [PMID: 16572450 DOI: 10.1002/bit.20952] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Streamline Direct CST I is a new type of ion exchanger with multi-modal functional groups, specially designed for an expanded bed adsorption (EBA) process, which can capture directly the proteins from the high ionic strength feedstocks with a high binding capacity. In this study, an experimental study is carried out for two-component proteins (BSA and myoglobin) competitive adsorption and desorption in an expanded bed packed with Streamline Direct CST I. Based on the measurements of the single- and two-component bovine serum albumin (BSA)/myoglobin adsorption isotherm on Streamline Direct CST I, the binding and elution conditions for the whole EBA process are selected; and then frontal analysis for a longer timescale and column displacement experiments in a fixed bed (XK16/20 column) are carried out to evaluate the two-component proteins (BSA and myoglobin) competitive adsorption and displacement on Streamline Direct CST I. Finally, the feasibility of capturing both BSA and myoglobin by an expanded bed packed with Streamline Direct CST I is addressed in a Streamline 50 column packed with 300 mL Streamline Direct CST I.
Collapse
|
36
|
Negatively charged sol-gel column with stable electroosmotic flow for online preconcentration of zwitterionic biomolecules in capillary electromigration separations. J Sep Sci 2005; 28:2153-64. [PMID: 16318212 DOI: 10.1002/jssc.200500172] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A negatively charged sol-gel coating was developed for on-line preconcentration of zwitterionic biomolecules in capillary electrophoresis (CE), using asparagine and myoglobin as representative zwitterionic bioanalytes. The sol-gel coating was created by using a solution containing three precursors: mercaptopropyltrimethoxysilane (MPTMS), tetramethoxysilane (TMOS), and n-octadecyltriethoxysilane (C18-TEOS). The resulting sol-gel coating contained chemically bonded mercaptopropyl functional groups that were further oxidized by hydrogen peroxide to the corresponding sulfonic acid moieties. Such a surface-bonded sol-gel coating can carry a negative charge over a wide range of pH due to the presence of deprotonated sulfonic acid groups. Under favorable pH conditions, the negatively charged sol-gel coating can facilitate the extraction of positively charged analytes from a zwitterionic sample through electrostatic interaction. This principle was employed to extract myoglobin and asparagine by passing aqueous samples of these zwitterionic analytes through a negatively charged sol-gel column. The extracted analytes were then desorbed and focused via local pH change and stacking. The local pH change was accomplished by passing a buffer solution with a pH above the solute p/ value, while a dynamic pH junction between the sample solution and the background electrolyte was utilized to facilitate solute focusing. The sorption/desorption phenomena could, perhaps, also be explained on the basis of ion-exchange and local pH junction effects. On-line preconcentration and analysis results obtained on sulfonated sol-gel columns were compared with those obtained on an uncoated fused silica capillary of identical dimensions using conventional sample injections. Using UV detection, the presented sample preconcentration technique provided a sensitivity enhancement factor (SEF) on the order of 3 x 10(3) for myoglobin, and 7 x 10(3) for asparagine.
Collapse
|
37
|
High-efficiency protein extraction from polyacrylamide gels for molecular mass measurement by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry. Electrophoresis 2005; 26:1019-28. [PMID: 15765489 DOI: 10.1002/elps.200410187] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A simple and fast method of protein extraction from Coomassie Brilliant Blue (CBB)-stained polyacrylamide gels suited for molecular mass measurement of proteins by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) is reported. Proteins in CBB-stained gel pieces were extracted by a 10-min soaking in 0.1 M NaOH at 25 degrees C. The recovery of this one-step extraction method was 34-73% for proteins <67 kDa. CBB adduction to proteins during mass spectrometric analysis was avoided by a destaining step before the alkaline extraction. The molecular mass values of the extracted proteins coincided with those of purified proteins within +/-0.01-0.10% deviation for all the proteins <36 kDa. Because of the high extraction recovery, mass measurement was possible for the proteins extracted from CBB-stained gels with loaded protein quantities as little as 34 ng for cytochrome c, alpha-lactalbumin, myoglobin, beta-lactoglobulin, trypsinogen, and carbonic anhydrase (12.4-29.0 kDa), 340 ng for glyceraldehyde-3-phosphate dehydrogenase (35.6 kDa) and albumin (66.3 kDa). This method provides a highly efficient approach to utilize CBB-stained one- or two-dimensional gels for whole protein analysis using MALDI-TOF-MS.
Collapse
|
38
|
Retention behavior of proteins in size-exclusion electrochromatography with a low-voltage electric field perpendicular to the liquid phase streamline. Electrophoresis 2005; 26:3084-93. [PMID: 16041710 DOI: 10.1002/elps.200500058] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A novel preparative size-exclusion electrochromatography with an oscillatory low-voltage electric field perpendicular to the liquid phase streamline (pSEEC) was proposed with a column design of rectangular cross-section. The column of 12 cm length was packed with Sephadex G-75, and the retention behavior of bovine serum albumin (BSA) and myoglobin (Myo) was extensively investigated under various conditions. The results indicated that the partition coefficient of a charged protein increased significantly on increasing the current strength as well as the difference between its pI and pH. The partition coefficient also increased on decreasing the mobile phase conductivity. For the gel-excluded protein like BSA, the concentration polarization (CP) on the gel surface induced by the protein electromigration was the main reason for the increased retention. For a gel-permeable protein like Myo, both the CP and electrophoretic migration in the solid phase contributed to its increased retention. Further results exhibited that the polarization would be offset by diffusion, because the accumulated protein would flux back to the bulk liquid phase. Therefore, when the electrically induced mass flux was equal to the diffusion flux, the partition coefficient did not change with a further increase of the oscillatory current cycle. Finally, pSEEC was compared with SEC in the separation of protein mixtures of BSA/Myo as well as BSA/Myo/lysozyme. The results showed much better resolutions of the protein mixtures in pSEEC with the column as short as 12 cm. The potential of pSEEC for preparative protein separation was therefore demonstrated.
Collapse
|
39
|
Functional and structural characterization of the myoglobin from the polychaete Ophelia bicornis. Biochem J 2005; 389:497-505. [PMID: 15796716 PMCID: PMC1175128 DOI: 10.1042/bj20050267] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The myoglobin of the polychaete annelid Ophelia bicornis was isolated, purified to homogeneity and characterized. The primary structure, obtained from cDNA and protein sequencing, consists of 139 amino acid residues. The alignment with other globin sequences showed that O. bicornis myoglobin misses the pre-A helix and the first six residues of the A helix. The presence of a PheB10-GlnE7 haem distal residue pair is in agreement with the measured oxygen affinity (P50=0.85 mmHg; 1 mmHg=0.133 kPa) and the only slightly higher autoxidation rate constant (0.28 h(-1)) with respect to that of the sperm whale myoglobin mutant E7 His-->Gln (0.21 h(-1)) and to elephant myoglobin (0.1 h(-1)). Oxygen-binding co-operativity was found to be absent under all the examined experimental conditions. The resistance of O. bicornis myoglobin towards autoxidation seems to confirm the important role of part of the A helix in the stability of the globin. The higher pKa of the acid-alkaline ferric transition of O. bicornis with respect to Asian elephant myoglobin, as well as the higher absorbance ratio of its ferric form to the oxy form measured in the Soret region (gammamet/gammaoxy) with respect to that of the African elephant myoglobin, suggested a stronger interaction between the distal glutamine and the water molecule at the sixth co-ordinate position.
Collapse
|
40
|
Polymer-supported scavengers for purification of labeled proteins. Anal Biochem 2005; 341:379-81. [PMID: 15907887 DOI: 10.1016/j.ab.2005.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2004] [Indexed: 11/22/2022]
|
41
|
Abstract
The model proteins cytochrome c, myoglobin, ovalbumin, and beta-lactoglobulin were investigated with regard to their adsorption properties on capillaries for electrophoresis. The model compounds were selected to cover a wide range of properties. Cytochrome c is a basic protein (isoelectric point (pI): 9.6; M(r): 11.7 kDa), beta-lactoglobulin is rather acidic (pI: 5.4, M(r): 18.4 kDa), myoglobin was chosen as a neutral reference protein (pI: 6.8-7.4, M(r): 17.8 kDa), and ovalbumin (pI: 5.1, M(r): 45.0 kDa) was selected as a relatively larger analyte. First, the pH dependence of adsorption was investigated for the bare fused silica. A clear correlation to the respective pIs was noted. For myoglobin and ovalbumin, none or negligible adsorption was found above the pI, whereas strong adsorption was noted just below this parameter. Cytochrome c and beta-lactoglobulin already showed distinct adsorption above their pIs. However, none of the proteins showed any significant adsorption more than one pH unit above the pIs. For linear polyacrylamide-coated capillaries, a decreased but not a complete lack of adsorption was observed. Here, pH-dependent adsorption was noted as well. Regeneration of the capillaries by rinsing with buffers containing 200 mM SDS was also investigated. This method was completely successful for myoglobin, but that too for only freshly-adsorbed protein. After a storage time of 24 h and due to the aging of the adsorbate, a sufficient regeneration was no longer possible.
Collapse
|
42
|
Determination of picomolar concentrations of proteins using novel amino reactive chameleon labels and capillary electrophoresis laser-induced fluorescence detection. Electrophoresis 2005; 26:2208-13. [PMID: 15880625 DOI: 10.1002/elps.200410332] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Py-1 and Py-6 are novel amino-reactive fluorescent reagents. The names given to them reflect that they consist of a pyrylium group attached to small aromatic moieties. Upon reaction with a primary amine there is a large spectral shift in the reagent, rendering them effectively fluorogenic. In this study, these reagents were used to label a test protein, (human serum albumin), and the sample was analyzed by capillary electrophoresis and laser-induced fluorescence detection. Detection limits after a 60 min labeling reaction at 22 degrees C (Py-1) and 50 degrees C (Py-6) were 6.5 ng/mL (98 pM) for Py-1 and 1.2 ng/mL (18 pM) for Py-6. Separation of immunoglobulin G (IgG), human serum albumin, lipase, and myoglobin after labeling with Py-6 were performed. The method was further modified to make it amenable to automation. Unlike many other amino reactive reagents used to label protein amino groups, reaction with Py-1 and Py-6 do not alter the charge of the protein and the advantage of this with respect to electrophoretic separations is discussed.
Collapse
|
43
|
Abstract
Capillary isoelectric focusing (CIEF) is an important tool for the quality assurance of biotechnologically maintained drugs and for proteome analysis. The critical performance parameters of this technique are the precisions of isoelectric point (pI) values and peak areas. Compared to capillary zone electrophoresis (CZE), where precise results can be obtained (e.g., 0.5% relative standard deviation (RSD) for peak areas, n = 60), only few data are available for CIEF experiments. So far, reproducible data of pI values (RSD = 0.5%) have been acquired, but peak areas show inferior results (about 3-15% RSD). Nonstable capillary coatings and protein adsorption have been discussed as possible reasons. Recent work of Righetti et al. [25, 27] has proven that the use of coated capillaries can reduce the adsorption of proteins by 50% but cannot prevent it. In our CIEF experiments irregular and poorly reproducible peak patterns have been observed. In a long-time experiment of 106 repeated runs, an overall RSD of 10% was obtained for peak areas, RSD of 2% only in series of about 10 consecutive replicates. Especially at higher concentrations the reproducibility deteriorates. This seems to be the result of a self-amplifying process, induced by adsorbed protein molecules, leading to further agglomerations. CZE control experiments in linear polyacrylamide (LPA)-coated capillaries proved a strong pH dependency of these effects within a small range. Compared to bare fused-silica surfaces, adsorption effects are reduced but not inhibited. An enhancement of reproducibility in CIEF experiments can be achieved only by controlling the interactions of proteins and capillary walls.
Collapse
|
44
|
Application of dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium in wall modification for capillary electrophoresis separation of proteins. Electrophoresis 2005; 26:586-92. [PMID: 15690431 DOI: 10.1002/elps.200410273] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3-), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3-12. At high DSB concentration, the EOF was suppressed by more than 8.8 times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl-, Br-, I-, SO4(2-), CO3(2-), and ClO4-, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2 min with the efficiencies from 24,000 to 1,310,000 plates/m. In the presence of ClO4- as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and myoglobin) yielded efficiencies of 204,000-896,000 plates/m and recoveries of 88%-98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation.
Collapse
|
45
|
High-Throughput Mass Spectrometer Using Atmospheric Pressure Ionization and a Cylindrical Ion Trap Array. Anal Chem 2004; 77:459-70. [PMID: 15649041 DOI: 10.1021/ac048983w] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.
Collapse
|
46
|
Abstract
Separation and detection of proteins have been realized on nonionic surfactant-modified poly(dimethylsiloxane) (PDMS) microfabricated devices with end-column amperometric detection. The hydrophobic PDMS channels are turned into hydrophilic ones after being modified with Brij35 and facilitate the separation of proteins. The coating can remarkably reduce the adsorption of large protein molecules and is stable in the range of pH 6-12. The detection of proteins in such channels needs less rinsing time and thus efficiency is raised. Even large molecules of proteins can also be detected with better reproducibility and enhanced plate numbers. The relative standard deviation (RSD) of the migration time for glucose oxidase (GOD) is 2.2% (n = 19). Separation of GOD and myoglobin has been developed in modified channels. Predominant operational variables, such as the coating conditions, the concentration of surfactant and buffer, are studied in detail.
Collapse
|
47
|
Identification of 4-hydroxy-2-nonenal-modified peptides within unfractionated digests using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Anal Chem 2004; 76:867-73. [PMID: 14961714 DOI: 10.1021/ac0303822] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The lipid peroxidation product 4-hydroxy-2-nonenal (HNE) is generated as a consequence of oxidative stress and can readily react with nucleophilic sites of proteins (e.g., histidine residues), mainly via a Michael addition. The formation of such lipid-protein conjugates can alter protein properties and biological functions, thus leading to highly deleterious effects. The present work describes a rapid (very limited sample preparation) and sensitive (low-femtomole range) procedure to identify HNE-modified peptides (Michael adducts) within unfractionated tryptic digests. The protocol involves the formation of dinitrophenylhydrazones of the Michael adducts, when using 2,4-dinitrophenylhydrazine as reactive matrix, followed by analysis using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The hydrazone derivatives present high desorption/ionization yield and can thus be preferentially detected compared to unmodified peptides. The MALDI mass spectrum obtained is therefore drastically different from the one obtained with the classical 4-hydroxy-alpha-cyanocinnamic acid matrix. Moreover, the presence of HNE, or more generally speaking carbonylated peptides, could be highlighted by 180 mass units differences (corresponding to the dinitrophenylhydrazone moiety) between these two MALDI mass spectra. Further information (e.g., localization/identification of the modified residues, peptide sequences) could be obtained by performing MALDI postsource decay (or electrospray) MS/MS experiments on the ions of interest.
Collapse
|
48
|
Abstract
The flexibility and selectivity of size exclusion chromatography (SEC) for protein purification can be modified by adding non-ionic micelle-forming surfactants to the mobile phase. The micelles exclude proteins from a liquid phase similar to the exclusion effect of the polymer fibers of the size exclusion resin. This surfactant-aided size exclusion chromatography technology (SASEC) is demonstrated on the separation of two model proteins; bovine serum albumin (BSA) and myoglobin (Myo). The effect of the added surfactants on the distribution behavior of the proteins is predicted adequately by a size exclusion model presented in this paper.
Collapse
|
49
|
Origin of the anomalous circular dichroism spectra of many apomyoglobin mutants. Anal Biochem 2004; 329:300-6. [PMID: 15158491 DOI: 10.1016/j.ab.2004.01.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2003] [Indexed: 11/22/2022]
Abstract
Several authors have reported that many sperm whale apomyoglobin mutants show anomalous circular dichroism spectra. These mutants have a low molar ellipticity compared to the wild-type protein but in several cases have the same stability of unfolding. A model in which native apomyoglobin is not folded in the same manner as that in other proteins and in which mutants show progressive reductions in their degree of folding has been suggested to explain this phenomenon. However, nuclear magnetic resonance of the native apomyoglobin conformation has shown that this state is folded and compact, raising the possibility that the anomalous circular dichroism spectra could have another explanation. We studied several mutants with anomalous circular dichroism spectra and found that these proteins were all contaminated with nucleic acid that contributed to the ultraviolet absorption and caused uncertainty in the determination of protein concentration. The resulting overestimation of the concentration of apomyoglobin explains the phenomenon of anomalous circular dichroism spectra. We describe a procedure to remove the contaminant nucleic acid which yields accurate protein concentration measurements and provides the normal circular dichroism spectra. Our findings support a well-structured native conformation for apomyoglobin and may also be of the interest to scientists working with the purification of recombinant proteins.
Collapse
|
50
|
[The solute clearance of dialyzer depends partly on its membrane material]. NIHON RINSHO. JAPANESE JOURNAL OF CLINICAL MEDICINE 2004; 62 Suppl 5:72-7. [PMID: 15197890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/29/2023]
|