Arjmandi MK, Jahn KN, Hem CB, Arenberg JG. Relationship Between Psychophysical Tuning Curves and Vowel Identification in Noise in Children and Adults With Cochlear Implants. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2025; 68:2623-2633. [PMID: 40268737 DOI: 10.1044/2025_jslhr-24-00270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2025]
Abstract
PURPOSE Perceptual outcomes in cochlear implant (CI) listeners are influenced by the quality of the interface between individual CI electrodes and their target auditory neurons (i.e., electrode-neuron interface [ENI]). Poor ENI increases the likelihood of CI channel interaction, which may lead to the smearing of sound frequency information, reduced spectral resolution, and, thus, errors in identifying speech sounds, particularly when there is background noise. This research note aims to present preliminary data on whether psychophysical tuning curves (PTCs), as a measure of channel interaction and an indirect measure of ENI, relate to vowel identification in noise in children and adults with CIs. METHOD PTCs and medial vowel identification in four-talker babble noise were obtained for eight children (12 ears) and eight adults (eight ears) with CIs. PTCs were measured for one electrode in the middle of the array using direct stimulation and a standard two-interval, two-alternative forced choice procedure. RESULTS Adults and children with sharper PTCs performed better on vowel identification in noise (F = 6.63, p = .02), demonstrating an association between less channel interaction and better vowel identification in noise in CI listeners irrespective of age. Although no statistically significant difference was found between children and adults in their PTC sharpness, children performed better than adults on vowel identification in noise (F = 5.38, p = .034). CONCLUSIONS The findings provide evidence that the sharpness of the PTC on a mid-array electrode is related to vowel identification in noise for CI listeners. Vowel identification in noise and PTC sharpness could be further investigated for use in developing personalized programming strategies that enhance the transmission of spectral cues crucial for recognizing vowel sounds.
Collapse
Affiliation(s)
- Meisam K Arjmandi
- Department of Communication Sciences and Disorders, University of South Carolina, Columbia
- Institute for Mind and Brain, University of South Carolina, Columbia
| | - Kelly N Jahn
- Department of Speech, Language, and Hearing, The University of Texas at Dallas, Richardson
- Callier Center for Communication Disorders, The University of Texas at Dallas, Richardson
| | - Charles B Hem
- Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston
| | - Julie G Arenberg
- Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston
| |
Collapse
|
2
|
Mohan P, Sinkkonen ST, Sivonen V. The association of intraoperative electric field and neural excitation patterns of the cochlear implant with patient-related factors of age, gender, cochlear diameter, and postoperative speech measures. Hear Res 2024; 453:109131. [PMID: 39454419 DOI: 10.1016/j.heares.2024.109131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 09/27/2024] [Accepted: 10/14/2024] [Indexed: 10/28/2024]
Abstract
PURPOSE To assess the relationships between the electric field (EF) and neural excitation patterns in cochlear implants (CIs) and explore their associations with the cochlear diameter, patient age and gender, and postoperative speech recognition. METHOD The intraoperative transimpedance matrix (TIM) and spread of excitation (SOE) measures were computed to obtain their 50 % widths corresponding to six electrode contacts of a lateral-wall electrode array. The measures were then analyzed for intercorrelations, associations with the cochlear diameter, as well as age and gender-related differences. The relationships between the computed intraoperative measures and postimplant speech recognition were also studied. RESULTS The TIM and SOE 50 % widths present moderate correlations and exhibit differences between adults and children. The TIM 50 % widths show additional associations with the cochlear diameter and partly vary with the implantee's gender. Speech recognition was found to have a significant relationship with the exponential spread coefficients (ESCs) obtained for individual electrode contacts. CONCLUSION Although interrelated, the EF and neural excitation measures of the CI are associated with different variables. The ESC, derived from computations of the TIM, is the only measure linked to postoperative speech recognition.
Collapse
Affiliation(s)
- Priyanka Mohan
- Department of Otorhinolaryngology-Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
| | - Saku T Sinkkonen
- Department of Otorhinolaryngology-Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Ville Sivonen
- Department of Otorhinolaryngology-Head and Neck Surgery and Tauno Palva Laboratory, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| |
Collapse
|
3
|
Farrar R, Ashjaei S, Arjmandi MK. Speech-evoked cortical activities and speech recognition in adult cochlear implant listeners: a review of functional near-infrared spectroscopy studies. Exp Brain Res 2024; 242:2509-2530. [PMID: 39305309 PMCID: PMC11527908 DOI: 10.1007/s00221-024-06921-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 09/04/2024] [Indexed: 11/01/2024]
Abstract
Cochlear implants (CIs) are the most successful neural prostheses, enabling individuals with severe to profound hearing loss to access sounds and understand speech. While CI has demonstrated success, speech perception outcomes vary largely among CI listeners, with significantly reduced performance in noise. This review paper summarizes prior findings on speech-evoked cortical activities in adult CI listeners using functional near-infrared spectroscopy (fNIRS) to understand (a) speech-evoked cortical processing in CI listeners compared to normal-hearing (NH) individuals, (b) the relationship between these activities and behavioral speech recognition scores, (c) the extent to which current fNIRS-measured speech-evoked cortical activities in CI listeners account for their differences in speech perception, and (d) challenges in using fNIRS for CI research. Compared to NH listeners, CI listeners had diminished speech-evoked activation in the middle temporal gyrus (MTG) and in the superior temporal gyrus (STG), except one study reporting an opposite pattern for STG. NH listeners exhibited higher inferior frontal gyrus (IFG) activity when listening to CI-simulated speech compared to natural speech. Among CI listeners, higher speech recognition scores correlated with lower speech-evoked activation in the STG, higher activation in the left IFG and left fusiform gyrus, with mixed findings in the MTG. fNIRS shows promise for enhancing our understanding of cortical processing of speech in CI listeners, though findings are mixed. Challenges include test-retest reliability, managing noise, replicating natural conditions, optimizing montage design, and standardizing methods to establish a strong predictive relationship between fNIRS-based cortical activities and speech perception in CI listeners.
Collapse
Affiliation(s)
- Reed Farrar
- Department of Psychology, University of South Carolina, 1512 Pendleton Street, Columbia, SC, 29208, USA
| | - Samin Ashjaei
- Department of Communication Sciences and Disorders, University of South Carolina, 1705 College Street, Columbia, SC, 29208, USA
| | - Meisam K Arjmandi
- Department of Communication Sciences and Disorders, University of South Carolina, 1705 College Street, Columbia, SC, 29208, USA.
- Institute for Mind and Brain, University of South Carolina, Barnwell Street, Columbia, SC, 29208, USA.
| |
Collapse
|
4
|
Adenis V, Partouche E, Stahl P, Gnansia D, Huetz C, Edeline JM. Asymmetric pulses delivered by a cochlear implant allow a reduction in evoked firing rate and in spatial activation in the guinea pig auditory cortex. Hear Res 2024; 447:109027. [PMID: 38723386 DOI: 10.1016/j.heares.2024.109027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 04/30/2024] [Accepted: 05/02/2024] [Indexed: 05/25/2024]
Abstract
Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong "polarity-order" effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.
Collapse
Affiliation(s)
- V Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - E Partouche
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - P Stahl
- Oticon Medical, Vallauris, France
| | | | - C Huetz
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - J-M Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France.
| |
Collapse
|
5
|
Rader T, Nachtigäller P, Linke T, Weißgerber T, Baumann U. Exponential fitting of spread of excitation response measurements in cochlear implants. J Neurosci Methods 2023; 391:109854. [PMID: 37031765 DOI: 10.1016/j.jneumeth.2023.109854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 03/31/2023] [Accepted: 04/06/2023] [Indexed: 04/11/2023]
Abstract
BACKGROUND Hearing performance in cochlear implant (CI) users is variable. An objective measure which can allow a prediction of this performance is desirable. Spread of neural excitation (SoE) curves are an objective measure that can be obtained using the fitting software of cochlear implants and might be able to be used as a predictor. A novel method to interpret SoE curves is presented. New Method Spread of excitation measurements for three recording sites were fitted using two exponential functions. An asymmetric width measure was developed, defined as the distance in mm to the point, where 25% or 50% of peak normalized amplitude was reached, for each half of the SoE separately. Also, a novel population of subjects with MED-EL CIs is used. Furthermore, speech perception (speech reception threshold, SRT) was evaluated using a matrix sentence test in a multi-source noise field. RESULTS SoE width was narrowest for the basal recording site and widest for the apical recording site. Fitted SoE exponential functions were most asymmetric for the apical recording site. A significant positive correlation between sentence test SRT and SoE width at the apical recording site was found. Comparison with Existing Methods The use of an asymmetric width measure correlated strongly and positively with speech perception for apical recording sites, unlike the symmetric width measure used in previous studies. Presumably, longer electrodes allow stimulation of a more apical part of the cochlear. At the apical part of the cochlea, dendrites from a large region of the basilar membrane map to a narrow portion on the spiral ganglion, which might explain the observed asymmetry. CONCLUSIONS For subjects implanted with long electrode arrays, an asymmetric width measure correlates positively with apical SoE distance. However, due to lack of a sufficient amount of data, the results are currently less conclusive and need to be consolidated in a larger cohort of subjects.
Collapse
Affiliation(s)
- Tobias Rader
- Division of Audiology, Department for Otorhinolaryngology, University Hospital, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Pascal Nachtigäller
- Division of Audiology, Department for Otorhinolaryngology, University Hospital, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Theresa Linke
- Dermatology Bad Soden, Bad Soden, Germany; Division of Audiological Acoustics, Department for Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| | - Tobias Weißgerber
- Division of Audiological Acoustics, Department for Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany.
| | - Uwe Baumann
- Division of Audiological Acoustics, Department for Otorhinolaryngology, University Hospital Frankfurt, Frankfurt, Germany
| |
Collapse
|
6
|
Guevara N, Truy E, Hoen M, Hermann R, Vandersteen C, Gallego S. Electrical Field Interactions during Adjacent Electrode Stimulations: eABR Evaluation in Cochlear Implant Users. J Clin Med 2023; 12:jcm12020605. [PMID: 36675534 PMCID: PMC9865217 DOI: 10.3390/jcm12020605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 01/15/2023] Open
Abstract
The present study investigates how electrically evoked Auditory Brainstem Responses (eABRs) can be used to measure local channel interactions along cochlear implant (CI) electrode arrays. eABRs were recorded from 16 experienced CI patients in response to electrical pulse trains delivered using three stimulation configurations: (1) single electrode stimulations (E11 or E13); (2) simultaneous stimulation from two electrodes separated by one (En and En+2, E11 and E13); and (3) stimulations from three consecutive electrodes (E11, E12, and E13). Stimulation level was kept constant at 70% electrical dynamic range (EDR) on the two flanking electrodes (E11 and E13) and was varied from 0 to 100% EDR on the middle electrode (E12). We hypothesized that increasing the middle electrode stimulation level would cause increasing local electrical interactions, reflected in characteristics of the evoked compound eABR. Results show that group averaged eABR wave III and V latency and amplitude were reduced when stimulation level at the middle electrode was increased, in particular when stimulation level on E12 reached 40, 70, and 100% EDR. Compound eABRs can provide a detailed individual quantification of electrical interactions occurring at specific electrodes along the CI electrode array. This approach allows a fine determination of interactions at the single electrode level potentially informing audiological decisions regarding mapping of CI systems.
Collapse
Affiliation(s)
- Nicolas Guevara
- Institut Universitaire de la Face et du Cou, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Eric Truy
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, Lyon 1 University, 69437 Lyon, France
| | - Michel Hoen
- Clinical Evidence Department, Oticon Medical, 06220 Vallauris, France
- Correspondence:
| | - Ruben Hermann
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, Lyon 1 University, 69437 Lyon, France
| | - Clair Vandersteen
- Institut Universitaire de la Face et du Cou, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Stéphane Gallego
- Institute for Readaptation Sciences and Techniques, Lyon 1 University, 69373 Lyon, France
| |
Collapse
|
7
|
Söderqvist S, Lamminmäki S, Aarnisalo A, Hirvonen T, Sinkkonen ST, Sivonen V. Intraoperative transimpedance and spread of excitation profile correlations with a lateral-wall cochlear implant electrode array. Hear Res 2021; 405:108235. [PMID: 33901994 DOI: 10.1016/j.heares.2021.108235] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 03/21/2021] [Accepted: 03/25/2021] [Indexed: 01/18/2023]
Abstract
A limiting factor of cochlear implant technology is the spread of electrode-generated intracochlear electrical field (EF) leading to spread of neural excitation (SOE). In this study, we investigated the relation of the spread of the intracochlear EF, assessed via transimpedance matrix (TIM), and SOE. A total of 43 consecutive patients (ages 0.7-82 years; 31.0 ± 25.7 years, mean ± SD) implanted with a Cochlear Nucleus CI522 or CI622 cochlear implant with Slim Straight electrode array (altogether 51 ears) were included in the study. Cochlear nerve was visualized for all patients in preoperative imaging and there were no cochlear anomalies in the study sample. The stimulated electrodes were in the basal, middle, and apical parts of the electrode array (electrode numbers 6, 11, and 19, respectively). The stimulation level was 210 CL on average for the TIM measurement and always 230 CL for the SOE measurement. Approximately 90% of the individual TIM and SOE profiles correlated with each other (p < .05; r = 0.61-0.99). Also, the widths of the TIM and SOE peaks, computed at 50% of the maximum height, exhibited a weak correlation (r = 0.39, p = .007). The 50% widths of TIM and SOE were the same only in the apical part of the electrode array; in the basal part SOE was wider than TIM, and in the middle part TIM was wider than SOE (p < .01 and p = .048, respectively). Within each measurement, TIM 50% widths were different between all three parts of the electrode array, while for SOE, only the basal electrode differed from the middle electrode. Finally, the size of the cochlea and the 50% widths of TIM and SOE had the strongest correlation in the middle part of the electrode array (r = -0.63, and -0.37, respectively). Our results suggest that there is a correlation between the spread of intracochlear EF and neural SOE at least in the apical part of the electrode array used in this study, and that larger cochleae are associated with more focused TIM and SOE.
Collapse
Affiliation(s)
- Samuel Söderqvist
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland.
| | - Satu Lamminmäki
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Antti Aarnisalo
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Timo Hirvonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Saku T Sinkkonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| | - Ville Sivonen
- Department of Otorhinolaryngology - Head and Neck Surgery, Head and Neck Center, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland
| |
Collapse
|
8
|
Cucis PA, Berger-Vachon C, Thaï-Van H, Hermann R, Gallego S, Truy E. Word Recognition and Frequency Selectivity in Cochlear Implant Simulation: Effect of Channel Interaction. J Clin Med 2021; 10:jcm10040679. [PMID: 33578696 PMCID: PMC7916371 DOI: 10.3390/jcm10040679] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 02/02/2021] [Accepted: 02/05/2021] [Indexed: 11/16/2022] Open
Abstract
In cochlear implants (CI), spread of neural excitation may produce channel interaction. Channel interaction disturbs the spectral resolution and, among other factors, seems to impair speech recognition, especially in noise. In this study, two tests were performed with 20 adult normal-hearing (NH) subjects under different vocoded simulations. First, there was a measurement of word recognition in noise while varying the number of selected channels (4, 8, 12 or 16 maxima out of 20) and the degree of simulated channel interaction (“Low”, “Medium” and “High”). Then, there was an evaluation of spectral resolution function of the degree of simulated channel interaction, reflected by the sharpness (Q10dB) of psychophysical tuning curves (PTCs). The results showed a significant effect of the simulated channel interaction on word recognition but did not find an effect of the number of selected channels. The intelligibility decreased significantly for the highest degree of channel interaction. Similarly, the highest simulated channel interaction impaired significantly the Q10dB. Additionally, a strong intra-individual correlation between frequency selectivity and word recognition in noise was observed. Lastly, the individual changes in frequency selectivity were positively correlated with the changes in word recognition when the degree of interaction went from “Low” to “High”. To conclude, the degradation seen for the highest degree of channel interaction suggests a threshold effect on frequency selectivity and word recognition. The correlation between frequency selectivity and intelligibility in noise supports the hypothesis that PTCs Q10dB can account for word recognition in certain conditions. Moreover, the individual variations of performances observed among subjects suggest that channel interaction does not have the same effect on each individual. Finally, these results highlight the importance of taking into account subjects’ individuality and to evaluate channel interaction through the speech processor.
Collapse
Affiliation(s)
- Pierre-Antoine Cucis
- Integrative, Multisensory, Perception, Action and Cognition Team (IMPACT), Lyon Neuroscience Research Center, CRNL Inserm U1028, CNRS UMR5292, 69675 Bron, France; (R.H.); (E.T.)
- Claude Bernard Lyon 1 University, 69100 Villeurbanne, France; (C.B.-V.); (H.T.-V.); (S.G.)
- ENT and Cervico-Facial Surgery Department, Edouard Herriot Hospital, Hospices Civils de Lyon, 69003 Lyon, France
- Correspondence: ; Tel.: +33-472-110-0518
| | - Christian Berger-Vachon
- Claude Bernard Lyon 1 University, 69100 Villeurbanne, France; (C.B.-V.); (H.T.-V.); (S.G.)
- Brain Dynamics and Cognition Team (DYCOG), Lyon Neuroscience Research Center, CRNL Inserm U1028, CNRS UMR5292, 69675 Bron, France
- Biomechanics and Impact Mechanics Laboratory (LBMC), French Institute of Science and Technology for Transport, Development and Networks (IFSTTAR), Gustave Eiffel University, 69675 Bron, France
| | - Hung Thaï-Van
- Claude Bernard Lyon 1 University, 69100 Villeurbanne, France; (C.B.-V.); (H.T.-V.); (S.G.)
- Paris Hearing Institute, Institut Pasteur, Inserm U1120, 75015 Paris, France
- Department of Audiology and Otoneurological Evaluation, Edouard Herriot Hospital, Hospices Civils de Lyon, 69003 Lyon, France
| | - Ruben Hermann
- Integrative, Multisensory, Perception, Action and Cognition Team (IMPACT), Lyon Neuroscience Research Center, CRNL Inserm U1028, CNRS UMR5292, 69675 Bron, France; (R.H.); (E.T.)
- Claude Bernard Lyon 1 University, 69100 Villeurbanne, France; (C.B.-V.); (H.T.-V.); (S.G.)
- ENT and Cervico-Facial Surgery Department, Edouard Herriot Hospital, Hospices Civils de Lyon, 69003 Lyon, France
| | - Stéphane Gallego
- Claude Bernard Lyon 1 University, 69100 Villeurbanne, France; (C.B.-V.); (H.T.-V.); (S.G.)
- Neuronal Dynamics and Audition Team (DNA), Laboratory of Cognitive Neuroscience (LNSC), CNRS UMR 7291, Aix-Marseille University, CEDEX 3, 13331 Marseille, France
| | - Eric Truy
- Integrative, Multisensory, Perception, Action and Cognition Team (IMPACT), Lyon Neuroscience Research Center, CRNL Inserm U1028, CNRS UMR5292, 69675 Bron, France; (R.H.); (E.T.)
- Claude Bernard Lyon 1 University, 69100 Villeurbanne, France; (C.B.-V.); (H.T.-V.); (S.G.)
- ENT and Cervico-Facial Surgery Department, Edouard Herriot Hospital, Hospices Civils de Lyon, 69003 Lyon, France
| |
Collapse
|
9
|
Canfarotta MW, Dillon MT, Buchman CA, Buss E, O'Connell BP, Rooth MA, King ER, Pillsbury HC, Adunka OF, Brown KD. Long-Term Influence of Electrode Array Length on Speech Recognition in Cochlear Implant Users. Laryngoscope 2020; 131:892-897. [PMID: 32738069 DOI: 10.1002/lary.28949] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 06/17/2020] [Accepted: 06/30/2020] [Indexed: 01/06/2023]
Abstract
OBJECTIVES/HYPOTHESIS Results from a prospective trial demonstrated better speech recognition for cochlear implant (CI) recipients implanted with a long lateral wall electrode array compared to subjects with a short array after 1 year of listening experience. As short array recipients may require an extended adaptation period, this study investigated whether differences in speech recognition continued through 4 years of CI use. STUDY DESIGN Long-term follow-up of a prospective randomized trial. METHODS Subjects were randomized to receive a MED-EL medium (24 mm) or standard (31.5 mm) array. Linear mixed models compared speech recognition between cohorts with word recognition in quiet and sentence recognition in noise at 1, 3, 6, 12, 24, and 48 months postactivation. Postoperative imaging and electric frequency filters were reviewed to assess the influence of frequency-to-place mismatch and angular separation between neighboring contacts, a metric associated with peripheral spectral selectivity. RESULTS Long (31.5 mm) array recipients demonstrated superior speech recognition out to 4 years postactivation. There was a significant effect of angular separation between contacts, with more closely spaced contacts associated with poorer speech recognition. There was no significant effect of mismatch, yet this may have been obscured by changes in frequency filters over time. CONCLUSIONS Conventional MED-EL CI recipients implanted with 31.5-mm arrays experience better speech recognition than 24-mm array recipients, initially and with long-term listening experience. The benefit conferred by longer arrays in the present cohort can be partially attributed to more widely spaced electrode contacts, presumably a result of reduced channel interaction. LEVEL OF EVIDENCE 2 Laryngoscope, 131:892-897, 2021.
Collapse
Affiliation(s)
- Michael W Canfarotta
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Margaret T Dillon
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Craig A Buchman
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine, St. Louis, Missouri, U.S.A
| | - Emily Buss
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Brendan P O'Connell
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Meredith A Rooth
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - English R King
- Department of Audiology, University of North Carolina Health Care, Chapel Hill, North Carolina, U.S.A
| | - Harold C Pillsbury
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Oliver F Adunka
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, U.S.A
| | - Kevin D Brown
- Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| |
Collapse
|
10
|
Auditory performance of post-lingually deafened adult cochlear implant recipients using electrode deactivation based on postoperative cone beam CT images. Eur Arch Otorhinolaryngol 2020; 278:977-986. [PMID: 32588169 DOI: 10.1007/s00405-020-06156-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 06/18/2020] [Indexed: 01/04/2023]
Abstract
PURPOSE The use of image processing techniques to estimate the position of intra-cochlear electrodes has enabled the creation of personalized maps to meet the individual stimulation needs of cochlear implant (CI) recipients. The aim of this study was to evaluate a novel technique of electrode deactivation based on postoperative cone beam computed tomography (CBCT) images in post-lingually deafened adult CI recipients. METHODS Based on postoperative CBCT images, the positioning of the electrodes was estimated in relation to the modiolus in 14 ears of 13 post-lingually deafened adult CI recipients. The electrodes sub-optimally positioned or involved in kinking and tip fold-over were deactivated. Speech perception scores in silence and in noise were obtained from subjects using the standard map and were followed up 4 weeks after image-based electrode deactivation reprogramming technique (IBEDRT). The participants selected their preferred map after 4 weeks of IBEDRT use. RESULTS There were statistically significant improvements in the speech recognition tests in silence and noise when comparing IBEDRT performance to the standard map. All participants elected the IBEDRT as their new preferred map. CONCLUSIONS IBEDRT is a promising technique for fitting CI recipients and minimizing channel interaction increased by the positioning of the electrodes sub-optimally placed, thereby improving their auditory performance. We propose a novel electrode deactivation technique based on postoperative CBCT imaging, with a limited number of deactivated electrodes and a low-dosing scanning which could be applied for clinical routine.
Collapse
|
11
|
Outcomes for a clinically representative cohort of hearing-impaired adults using the Nucleus® CI532 cochlear implant. Eur Arch Otorhinolaryngol 2020; 277:1625-1635. [PMID: 32140773 PMCID: PMC7198645 DOI: 10.1007/s00405-020-05893-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Accepted: 02/17/2020] [Indexed: 11/03/2022]
Abstract
PURPOSE Hearing performance data was collected from a large heterogeneous group of subjects implanted with the Cochlear™ Nucleus® CI532 with Slim Modiolar Electrode, for the purposes of postmarket clinical follow-up. Data was analysed for factors which may predict postoperative speech recognition scores. METHODS Data was collected retrospectively from five German clinics for 159 subjects from March 2017 to August 2018. Hearing thresholds and recognition scores for monosyllabic words in quiet and sentences in noise were measured preoperatively and at 3 and 6 months postoperatively. RESULTS There was a mean gain of 44% points (95% CI 39-49%) at 6 months in monosyllable scores in quiet for implanted ears. Preoperative hearing thresholds in implant ears increased systematically with decreasing age; however, younger subjects had better baseline monosyllable scores with hearing aids compared with older subjects. Baseline performance alone explained 14% of the variation in postoperative scores. Residual hearing was preserved on average to within 22 dB at 250 Hz and 30 dB at 500 Hz of preoperative levels. CONCLUSIONS In a large and varied cohort of routinely treated hearing-impaired adults, speech recognition with the CI532 for German monosyllabic words in quiet at 6 months was equivalent to performance reported at one year or more in other published studies. Although younger subjects had poorer preoperative pure-tone thresholds, they had better preoperative word recognition scores compared with older subjects, and also had higher post implant scores. Further research is required to identify if this phenomenon is just applicable to German health system assessment and referral practices.
Collapse
|
12
|
Hey M, Wesarg T, Mewes A, Helbig S, Hornung J, Lenarz T, Briggs R, Marx M, Ramos A, Stöver T, Escudé B, James CJ, Aschendorff A. Objective, audiological and quality of life measures with the CI532 slim modiolar electrode. Cochlear Implants Int 2018; 20:80-90. [DOI: 10.1080/14670100.2018.1544684] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Matthias Hey
- Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | | | | | - Silke Helbig
- Klinikum der J. W. Goethe-Universität, Frankfurt, Germany
| | | | | | | | - Mathieu Marx
- Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Angel Ramos
- Complejo Hospitalario Universitario Insular Materno Infantil, Las Palmas, Spain
| | - Timo Stöver
- Klinikum der J. W. Goethe-Universität, Frankfurt, Germany
| | | | - Chris J. James
- Centre Hospitalier Universitaire de Toulouse, Toulouse, France
- Cochlear France SAS, Toulouse, France
| | | |
Collapse
|
13
|
Feng L, Oxenham AJ. Auditory enhancement and the role of spectral resolution in normal-hearing listeners and cochlear-implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:552. [PMID: 30180692 PMCID: PMC6072550 DOI: 10.1121/1.5048414] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 06/25/2018] [Accepted: 07/11/2018] [Indexed: 05/17/2023]
Abstract
Detection of a target tone in a simultaneous multi-tone masker can be improved by preceding the stimulus with the masker alone. The mechanisms underlying this auditory enhancement effect may enable the efficient detection of new acoustic events and may help to produce perceptual constancy under varying acoustic conditions. Previous work in cochlear-implant (CI) users has suggested reduced or absent enhancement, due perhaps to poor spatial resolution in the cochlea. This study used a supra-threshold enhancement paradigm that in normal-hearing listeners results in large enhancement effects, exceeding 20 dB. Results from vocoder simulations using normal-hearing listeners showed that near-normal enhancement was observed if the simulated spread of excitation was limited to spectral slopes no shallower than 24 dB/oct. No significant enhancement was observed on average in CI users with their clinical monopolar stimulation strategy. The variability in enhancement between CI users, and between electrodes in a single CI user, could not be explained by the spread of excitation, as estimated from auditory nerve evoked potentials. Enhancement remained small, but did reach statistical significance, under the narrower partial-tripolar stimulation strategy. The results suggest that enhancement may be at least partially restored by improvements in the spatial resolution of current CIs.
Collapse
Affiliation(s)
- Lei Feng
- Department of Psychology, University of Minnesota, N218 Elliott Hall, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| | - Andrew J Oxenham
- Department of Psychology, University of Minnesota, N218 Elliott Hall, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| |
Collapse
|
14
|
DeVries L, Arenberg JG. Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners. J Assoc Res Otolaryngol 2018; 19:571-587. [PMID: 29869047 DOI: 10.1007/s10162-018-0678-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 05/23/2018] [Indexed: 01/04/2023] Open
Abstract
Speech understanding abilities vary widely among cochlear implant (CI) listeners. A potential source of this variability is the electrode-neuron interface (ENI), which includes peripheral factors such as electrode position and integrity of remaining spiral ganglion neurons. Suboptimal positioning of the electrode array has been associated with poorer speech outcomes; however, postoperative computerized tomography (CT) scans are often not available to clinicians. CT-estimated electrode-to-modiolus distance (distance from the inner wall of the cochlea) has been shown to account for some variability in behavioral thresholds. However, psychophysical tuning curves (PTCs) may provide additional insight into site-specific variation in channel interaction. Thirteen unilaterally implanted adults with the Advanced Bionics HiRes90K device participated. Behavioral thresholds and PTCs were collected for all available electrodes with steered quadrupolar (sQP) configuration, using a modified threshold sweep procedure, used in Bierer et al. (Trends Hear 19:1-12, 2015). PTC bandwidths were quantified to characterize channel interaction across the electrode array, and tip shifts were assessed to identify possible contributions of neural dead regions. Broader PTC bandwidths were correlated with electrodes farther from the modiolus, but not correlated with sQP threshold, though a trend was observed. Both measures were affected by scalar location, and PTC tip shifts were observed for electrodes farther from the modiolus. sQP threshold was the only variable correlated with word recognition. These results suggest PTCs may be used as a site-specific measure of channel interaction that correlates with electrode position in some CI listeners.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98106, USA.
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98106, USA
| |
Collapse
|
15
|
Jürgens T, Hohmann V, Büchner A, Nogueira W. The effects of electrical field spatial spread and some cognitive factors on speech-in-noise performance of individual cochlear implant users-A computer model study. PLoS One 2018; 13:e0193842. [PMID: 29652892 PMCID: PMC5898708 DOI: 10.1371/journal.pone.0193842] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 02/19/2018] [Indexed: 11/18/2022] Open
Abstract
The relation of the individual speech-in-noise performance differences in cochlear implant (CI) users to underlying physiological factors is currently poorly understood. This study approached this research question by a step-wise individualization of a computer model of speech intelligibility mimicking the details of CI signal processing and some details of the physiology present in CI users. Two factors, the electrical field spatial spread and internal noise (as a coarse model of the individual cognitive performance) were incorporated. Internal representations of speech-in-noise mixtures calculated by the model were classified using an automatic speech recognizer backend employing Hidden Markov Models with a Gaussian probability distribution. One-dimensional electric field spatial spread functions were inferred from electrical field imaging data of 14 CI users. Simplified assumptions of homogenously distributed auditory nerve fibers along the cochlear array and equal distance between electrode array and nerve tissue were assumed in the model. Internal noise, whose standard deviation was adjusted based on either anamnesis data, or text-reception-threshold data, or a combination thereof, was applied to the internal representations before classification. A systematic model evaluation showed that predicted speech-reception-thresholds (SRTs) in stationary noise improved (decreased) with decreasing internal noise standard deviation and with narrower electric field spatial spreads. The model version that was individualized to actual listeners using internal noise alone (containing average spatial spread) showed significant correlations to measured SRTs, reflecting the high correlation of the text-reception threshold data with SRTs. However, neither individualization to spatial spread functions alone, nor a combined individualization based on spatial spread functions and internal noise standard deviation did produce significant correlations with measured SRTs.
Collapse
Affiliation(s)
- Tim Jürgens
- Medizinische Physik, Cluster of Excellence “Hearing4all” and Forschungszentrum Neurosensorik, Carl-von-Ossietzky Universität Oldenburg, Germany
- * E-mail:
| | - Volker Hohmann
- Medizinische Physik, Cluster of Excellence “Hearing4all” and Forschungszentrum Neurosensorik, Carl-von-Ossietzky Universität Oldenburg, Germany
| | - Andreas Büchner
- Medical University Hannover, Cluster of Excellence “Hearing4all”, Hannover, Germany
| | - Waldo Nogueira
- Medical University Hannover, Cluster of Excellence “Hearing4all”, Hannover, Germany
| |
Collapse
|
16
|
Imsiecke M, Krüger B, Büchner A, Lenarz T, Nogueira W. Electric-acoustic forward masking in cochlear implant users with ipsilateral residual hearing. Hear Res 2018; 364:25-37. [PMID: 29673567 DOI: 10.1016/j.heares.2018.04.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 03/07/2018] [Accepted: 04/02/2018] [Indexed: 11/16/2022]
Abstract
In order to investigate the temporal mechanisms of the auditory system, psychophysical forward masking experiments were conducted in cochlear implant users who had preserved acoustic hearing in the ipsilateral ear. This unique electric-acoustic stimulation (EAS) population allowed the measurement of threshold recovery functions for acoustic or electric probes in the presence of electric or acoustic maskers, respectively. In the electric masking experiment, the forward masked threshold elevation of acoustic probes was measured as a function of the time interval after the offset of the electric masker, i.e. the masker-to-probe interval (MPI). In the acoustic masking experiment, the forward masked threshold elevation of electric probe stimuli was investigated under the influence of a preceding acoustic masker. Since electric pulse trains directly stimulate the auditory nerve, this novel experimental setup allowed the acoustic adaptation properties (attributed to the physiology of the hair cells) to be differentiated from the subsequent processing by more central mechanisms along the auditory pathway. For instance, forward electric masking patterns should result more from the auditory-nerve response to electrical stimulation, while forward acoustic masking patterns should primarily be the result of the recovery from adaptation at the hair-cell neuron interface. Electric masking showed prolonged threshold elevation of acoustic probes, which depended significantly on the masker-to-probe interval. Additionally, threshold elevation was significantly dependent on the similarity between acoustic stimulus frequency and electric place frequency, the electric-acoustic frequency difference (EAFD). Acoustic masking showed a reduced, but statistically significant effect of electric threshold elevation, which did not significantly depend on MPI. Lastly, acoustic masking showed longer decay times than electric masking and a reduced dependency on EAFD. In conclusion, the forward masking patterns observed for combined electric-acoustic stimulation provide further insights into the temporal mechanisms of the auditory system. For instance, the asymmetry in the amount of threshold elevation, the dependency on EAFD and the time constants for the recovery functions of acoustic and electric masking all indicate that there must be several processes with different latencies (e.g. neural adaptation, depression of spontaneous activity, efferent systems) that are involved in forward masking recovery functions.
Collapse
Affiliation(s)
- Marina Imsiecke
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany.
| | - Benjamin Krüger
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany; Cluster of Excellence 'Hearing4All', Hanover, Germany.
| | - Andreas Büchner
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany; Cluster of Excellence 'Hearing4All', Hanover, Germany.
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany; Cluster of Excellence 'Hearing4All', Hanover, Germany.
| | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany; Cluster of Excellence 'Hearing4All', Hanover, Germany.
| |
Collapse
|
17
|
He S, Teagle HFB, Buchman CA. The Electrically Evoked Compound Action Potential: From Laboratory to Clinic. Front Neurosci 2017; 11:339. [PMID: 28690494 PMCID: PMC5481377 DOI: 10.3389/fnins.2017.00339] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Accepted: 05/30/2017] [Indexed: 11/13/2022] Open
Abstract
The electrically evoked compound action potential (eCAP) represents the synchronous firing of a population of electrically stimulated auditory nerve fibers. It can be directly recorded on a surgically exposed nerve trunk in animals or from an intra-cochlear electrode of a cochlear implant. In the past two decades, the eCAP has been widely recorded in both animals and clinical patient populations using different testing paradigms. This paper provides an overview of recording methodologies and response characteristics of the eCAP, as well as its potential applications in research and clinical situations. Relevant studies are reviewed and implications for clinicians are discussed.
Collapse
Affiliation(s)
- Shuman He
- Center for Hearing Research, Boys Town National Research HospitalOmaha, NE, United States
| | - Holly F. B. Teagle
- Department of Otolaryngology—Head and Neck Surgery, University of North Carolina at Chapel HillChapel Hill, NC, United States
| | - Craig A. Buchman
- Department of Otolaryngology—Head and Neck Surgery, Washington UniversitySt. Louis, MO, United States
| |
Collapse
|
18
|
Scheperle RA. Suprathreshold compound action potential amplitude as a measure of auditory function in cochlear implant users. J Otol 2017; 12:18-28. [PMID: 29937833 PMCID: PMC6011805 DOI: 10.1016/j.joto.2017.01.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Revised: 01/02/2017] [Accepted: 01/04/2017] [Indexed: 10/28/2022] Open
Abstract
Electrically evoked compound action potential (eCAP) amplitudes elicited at suprathreshold levels were assessed as a measure of the effectiveness of cochlear implant (CI) stimulation. Twenty-one individuals participated; one was excluded due to facial stimulation during eCAP testing. For each participant, eCAPs were elicited with stimulation from seven electrodes near the upper limit of the individual's electrical dynamic range. A reduced-channel CI program was created using those same seven electrodes, and participants performed a vowel discrimination task. Consistent with previous reports, eCAP amplitudes varied across tested electrodes; the profiles were unique to each individual. In 6 subjects (30%), eCAP amplitude variability was partially explained by the impedance of the recording electrode. The remaining amplitude variability within subjects, and the variability observed across subjects could not be explained by recording electrode impedance. This implies that other underlying factors, such as variations in neural status across the array, are responsible. Across-site mean eCAP amplitude was significantly correlated with vowel discrimination scores (r2 = 0.56). A single eCAP amplitude measured from the middle of the array was also significantly correlated with vowel discrimination, but the correlation was weaker (r2 = 0.37), though not statistically different from the across-site mean. Normalizing each eCAP amplitude by its associated recording electrode impedance did not improve the correlation with vowel discrimination (r2 = 0.52). Further work is needed to assess whether combining eCAP amplitude with other measures of the electrode-neural interface and/or with more central measures of auditory function provides a more complete picture of auditory function in CI recipients.
Collapse
|
19
|
Li H, Edin F, Hayashi H, Gudjonsson O, Danckwardt-Lillieström N, Engqvist H, Rask-Andersen H, Xia W. Guided growth of auditory neurons: Bioactive particles towards gapless neural - electrode interface. Biomaterials 2016; 122:1-9. [PMID: 28107660 DOI: 10.1016/j.biomaterials.2016.12.020] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Revised: 11/30/2016] [Accepted: 12/16/2016] [Indexed: 01/26/2023]
Abstract
Cochlear implant (CI) is a successful device to restore hearing. Despite continuous development, frequency discrimination is poor in CI users due to an anatomical gap between the auditory neurons and CI electrode causing current spread and unspecific neural stimulation. One strategy to close this anatomical gap is guiding the growth of neuron dendrites closer to CI electrodes through targeted slow release of neurotrophins. Biodegradable calcium phosphate hollow nanospheres (CPHSs) were produced and their capacity for uptake and release of neurotrophins investigated using 125I-conjugated glia cell line-derived neurotrophic factor (GDNF). The CPHSs were coated onto CI electrodes and loaded with neurotrophins. Axon guidance effect of slow-released neurotrophins from the CPHSs was studied in an in vitro 3D culture model. CPHS coating bound and released GDNF with an association rate constant 6.3 × 103 M-1s-1 and dissociation rate 2.6 × 10-5 s-1, respectively. Neurites from human vestibulocochlear ganglion explants found and established physical contact with the GDNF-loaded CPHS coating on the CI electrodes placed 0.7 mm away. Our results suggest that neurotrophin delivery through CPHS coating is a plausible way to close the anatomical gap between auditory neurons and electrodes. By overcoming this gap, selective neural activation and the fine hearing for CI users become possible.
Collapse
Affiliation(s)
- Hao Li
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Fredrik Edin
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | | | - Olafur Gudjonsson
- Neurosurgery, Department of Neuroscience, Uppsala University, Uppsala, Sweden
| | | | - Håkan Engqvist
- Applied Material Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | - Helge Rask-Andersen
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
| | - Wei Xia
- Applied Material Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
20
|
van Eijl RHM, Buitenhuis PJ, Stegeman I, Klis SFL, Grolman W. Systematic review of compound action potentials as predictors for cochlear implant performance. Laryngoscope 2016; 127:476-487. [PMID: 27804133 DOI: 10.1002/lary.26154] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 05/07/2016] [Accepted: 05/31/2016] [Indexed: 11/10/2022]
Abstract
OBJECTIVES/HYPOTHESIS The variability in speech perception between cochlear implant users is thought to result from the degeneration of the auditory nerve. Degeneration of the auditory nerve, histologically assessed, correlates with electrophysiologically acquired measures, such as electrically evoked compound action potentials (eCAPs) in experimental animals. To predict degeneration of the auditory nerve in humans, where histology is impossible, this paper reviews the correlation between speech perception and eCAP recordings in cochlear implant patients. DATA SOURCES PubMed and Embase. REVIEW METHODS We performed a systematic search for articles containing the following major themes: cochlear implants, evoked potentials, and speech perception. Two investigators independently conducted title-abstract screening, full-text screening, and critical appraisal. Data were extracted from the remaining articles. RESULTS Twenty-five of 1,429 identified articles described a correlation between speech perception and eCAP attributes. Due to study heterogeneity, a meta-analysis was not feasible, and studies were descriptively analyzed. Several studies investigating presence of the eCAP, recovery time constant, slope of the amplitude growth function, and spatial selectivity showed significant correlations with speech perception. In contrast, neural adaptation, eCAP threshold, and change with varying interphase gap did not significantly correlate with speech perception in any of the identified studies. CONCLUSIONS Significant correlations between speech perception and parameters obtained through eCAP recordings have been documented in literature; however, reporting was ambiguous. There is insufficient evidence for eCAPs as a predictive factor for speech perception. More research is needed to further investigate this relation. Laryngoscope, 2016 127:476-487, 2017.
Collapse
Affiliation(s)
- Ruben H M van Eijl
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, the Netherlands.,Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Patrick J Buitenhuis
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Inge Stegeman
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, the Netherlands.,Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Sjaak F L Klis
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, the Netherlands.,Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Wilko Grolman
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, the Netherlands.,Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
21
|
Bosen AK, Chatterjee M. Band importance functions of listeners with cochlear implants using clinical maps. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:3718. [PMID: 27908046 PMCID: PMC5392084 DOI: 10.1121/1.4967298] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Band importance functions estimate the relative contribution of individual acoustic frequency bands to speech intelligibility. Previous studies of band importance in listeners with cochlear implants have used experimental maps and direct stimulation. Here, band importance was estimated for clinical maps with acoustic stimulation. Listeners with cochlear implants had band importance functions that relied more heavily on lower frequencies and showed less cross-listener consistency than in listeners with normal hearing. The intersubject variability observed here indicates that averaging band importance functions across listeners with cochlear implants, as has been done in previous studies, may not be meaningful. Additionally, band importance functions of listeners with normal hearing for vocoded speech that either did or did not simulate spread of excitation were not different from one another, suggesting that additional factors beyond spread of excitation are necessary to account for changes in band importance in listeners with cochlear implants.
Collapse
Affiliation(s)
- Adam K Bosen
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Monita Chatterjee
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
22
|
Zhou N. Monopolar Detection Thresholds Predict Spatial Selectivity of Neural Excitation in Cochlear Implants: Implications for Speech Recognition. PLoS One 2016; 11:e0165476. [PMID: 27798658 PMCID: PMC5087957 DOI: 10.1371/journal.pone.0165476] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Accepted: 10/12/2016] [Indexed: 12/12/2022] Open
Abstract
The objectives of the study were to (1) investigate the potential of using monopolar psychophysical detection thresholds for estimating spatial selectivity of neural excitation with cochlear implants and to (2) examine the effect of site removal on speech recognition based on the threshold measure. Detection thresholds were measured in Cochlear Nucleus® device users using monopolar stimulation for pulse trains that were of (a) low rate and long duration, (b) high rate and short duration, and (c) high rate and long duration. Spatial selectivity of neural excitation was estimated by a forward-masking paradigm, where the probe threshold elevation in the presence of a forward masker was measured as a function of masker-probe separation. The strength of the correlation between the monopolar thresholds and the slopes of the masking patterns systematically reduced as neural response of the threshold stimulus involved interpulse interactions (refractoriness and sub-threshold adaptation), and spike-rate adaptation. Detection threshold for the low-rate stimulus most strongly correlated with the spread of forward masking patterns and the correlation reduced for long and high rate pulse trains. The low-rate thresholds were then measured for all electrodes across the array for each subject. Subsequently, speech recognition was tested with experimental maps that deactivated five stimulation sites with the highest thresholds and five randomly chosen ones. Performance with deactivating the high-threshold sites was better than performance with the subjects' clinical map used every day with all electrodes active, in both quiet and background noise. Performance with random deactivation was on average poorer than that with the clinical map but the difference was not significant. These results suggested that the monopolar low-rate thresholds are related to the spatial neural excitation patterns in cochlear implant users and can be used to select sites for more optimal speech recognition performance.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, United States of America
- * E-mail:
| |
Collapse
|
23
|
Hughes ML, Goehring JL, Baudhuin JL, Schmid KK. Effects of stimulus level and rate on psychophysical thresholds for interleaved pulse trains in cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:2297. [PMID: 27794318 PMCID: PMC6910005 DOI: 10.1121/1.4963903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 09/09/2016] [Accepted: 09/14/2016] [Indexed: 06/06/2023]
Abstract
This study examined channel interactions using interleaved pulse trains to assess masking and potential facilitative effects in cochlear-implant recipients using clinically relevant stimuli. Psychophysical thresholds were measured for two adjacent mid-array electrodes; one served as the masker and the other as the probe. Two rates representative of those found in present-day strategies were tested: 1700 and 3400 pulses per second per channel. Four masker levels ranging from sub-threshold to loud-but-comfortable were tested. It was hypothesized that low-level maskers would produce facilitative effects, shifting to masking effects at high levels, and that faster rates would yield smaller masking effects due to greater stochastic neural firing patterns. Twenty-nine ears with Cochlear or Advanced Bionics devices were tested. High-level maskers produced more masking than low-level maskers, as expected. Facilitation was not observed for sub-threshold or threshold-level maskers in most cases. High masker levels yielded reduced probe thresholds for two Advanced Bionics subjects. This was partly eliminated with a longer temporal offset between each masker-probe pulse pair, as was used with Cochlear subjects. These findings support the use of temporal gaps between stimulation of subsequent electrodes to reduce channel interactions.
Collapse
Affiliation(s)
- Michelle L Hughes
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Jenny L Goehring
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Jacquelyn L Baudhuin
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Kendra K Schmid
- Department of Biostatistics, 984375 University of Nebraska Medical Center, Omaha, Nebraska 68198-4375, USA
| |
Collapse
|
24
|
Reynolds S, Miller Kuhaneck H, Pfeiffer B. Systematic Review of the Effectiveness of Frequency Modulation Devices in Improving Academic Outcomes in Children With Auditory Processing Difficulties. Am J Occup Ther 2016; 70:7001220030p1-7001220030p11. [PMID: 26709423 DOI: 10.5014/ajot.2016.016832] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
This systematic review describes the published evidence related to the effectiveness of frequency modulation (FM) devices in improving academic outcomes in children with auditory processing difficulties. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses standards were used to identify articles published between January 2003 and March 2014. The Cochrane Population, Intervention, Control, Outcome, Study Design approach and the American Occupational Therapy Association process forms were used to guide the article selection and evaluation process. Of the 83 articles screened, 7 matched the systematic review inclusion criteria. Findings were consistently positive, although limitations were identified. Results of this review indicate moderate support for the use of FM devices to improve children's ability to listen and attend in the classroom and mixed evidence to improve specific academic performance areas. FM technology should be considered for school-age children with auditory processing impairments who are receiving occupational therapy services to improve functioning in the school setting.
Collapse
Affiliation(s)
- Stacey Reynolds
- Stacey Reynolds, PhD, OTR/L, is Associate Professor, Department of Occupational Therapy, Virginia Commonwealth University, Richmond;
| | - Heather Miller Kuhaneck
- Heather Miller Kuhaneck, PhD, OTR/L, FAOTA, is Associate Professor, Department of Occupational Therapy, Sacred Heart University, Fairfield, CT
| | - Beth Pfeiffer
- Beth Pfeiffer, PhD, OTR/L, BCP, is Associate Professor, Department of Rehabilitation Sciences, Temple University, Philadelphia, PA
| |
Collapse
|
25
|
DeVries L, Scheperle R, Bierer JA. Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds. J Assoc Res Otolaryngol 2016; 17:237-52. [PMID: 26926152 DOI: 10.1007/s10162-016-0557-9] [Citation(s) in RCA: 106] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Accepted: 02/04/2016] [Indexed: 11/26/2022] Open
Abstract
Variability in speech perception scores among cochlear implant listeners may largely reflect the variable efficacy of implant electrodes to convey stimulus information to the auditory nerve. In the present study, three metrics were applied to assess the quality of the electrode-neuron interface of individual cochlear implant channels: the electrically evoked compound action potential (ECAP), the estimation of electrode position using computerized tomography (CT), and behavioral thresholds using focused stimulation. The primary motivation of this approach is to evaluate the ECAP as a site-specific measure of the electrode-neuron interface in the context of two peripheral factors that likely contribute to degraded perception: large electrode-to-modiolus distance and reduced neural density. Ten unilaterally implanted adults with Advanced Bionics HiRes90k devices participated. ECAPs were elicited with monopolar stimulation within a forward-masking paradigm to construct channel interaction functions (CIF), behavioral thresholds were obtained with quadrupolar (sQP) stimulation, and data from imaging provided estimates of electrode-to-modiolus distance and scalar location (scala tympani (ST), intermediate, or scala vestibuli (SV)) for each electrode. The width of the ECAP CIF was positively correlated with electrode-to-modiolus distance; both of these measures were also influenced by scalar position. The ECAP peak amplitude was negatively correlated with behavioral thresholds. Moreover, subjects with low behavioral thresholds and large ECAP amplitudes, averaged across electrodes, tended to have higher speech perception scores. These results suggest a potential clinical role for the ECAP in the objective assessment of individual cochlear implant channels, with the potential to improve speech perception outcomes.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98105, USA.
| | - Rachel Scheperle
- Department of Communication Sciences and Disorders, Wendell Johnson Speech and Hearing Center, University of Iowa, Iowa City, Iowa, 52242, USA
| | - Julie Arenberg Bierer
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98105, USA
| |
Collapse
|
26
|
Cai Y, Edin F, Jin Z, Alexsson A, Gudjonsson O, Liu W, Rask-Andersen H, Karlsson M, Li H. Strategy towards independent electrical stimulation from cochlear implants: Guided auditory neuron growth on topographically modified nanocrystalline diamond. Acta Biomater 2016; 31:211-220. [PMID: 26593784 DOI: 10.1016/j.actbio.2015.11.021] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Revised: 11/10/2015] [Accepted: 11/14/2015] [Indexed: 12/14/2022]
Abstract
Cochlear implants (CI) have been used for several decades to treat patients with profound hearing loss. Nevertheless, results vary between individuals, and fine hearing is generally poor due to the lack of discrete neural stimulation from the individual receptor hair cells. A major problem is the deliverance of independent stimulation signals to individual auditory neurons. Fine hearing requires significantly more stimulation contacts with intimate neuron/electrode interphases from ordered axonal re-growth, something current CI technology cannot provide. Here, we demonstrate the potential application of micro-textured nanocrystalline diamond (NCD) surfaces on CI electrode arrays. Such textured NCD surfaces consist of micrometer-sized nail-head-shaped pillars (size 5×5μm(2)) made with sequences of micro/nano-fabrication processes, including sputtering, photolithography and plasma etching. The results show that human and murine inner-ear ganglion neurites and, potentially, neural progenitor cells can attach to patterned NCD surfaces without an extracellular matrix coating. Microscopic methods revealed adhesion and neural growth, specifically along the nail-head-shaped NCD pillars in an ordered manner, rather than in non-textured areas. This pattern was established when the inter-NCD pillar distance varied between 4 and 9μm. The findings demonstrate that regenerating auditory neurons show a strong affinity to the NCD pillars, and the technique could be used for neural guidance and the creation of new neural networks. Together with the NCD's unique anti-bacterial and electrical properties, patterned NCD surfaces could provide designed neural/electrode interfaces to create independent electrical stimulation signals in CI electrode arrays for the neural population. STATEMENT OF SIGNIFICANCE Cochlear implant is currently a successful way to treat sensorineural hearing loss and deafness especially in children. Although clinically successful, patients' fine hearing cannot be completely restored. One problem is the amount of the electrodes; 12-20 electrodes are used to replace the function of 3400 inner hair cells. Intense research is ongoing aiming to increase the number of electrodes. This study demonstrates the use of nanocrystalline diamond as a potential nerve-electrode interface. Micrometer-sized nanocrystalline diamond pillars showed high affinity to regenerated human neurons, which grew into a pre-defined network based on the pillar design. Our findings are of particular interest since they can be applied on any silicon-based implant to increase electrode count and to achieve individual neuron stimulation patterns.
Collapse
Affiliation(s)
- Yixiao Cai
- Department of Engineering Sciences, Ångström Laboratory, Uppsala University, Uppsala, Sweden
| | - Fredrik Edin
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Zhe Jin
- Physiology; Molecular Physiology and Neuroscience, Department of Neuroscience, Uppsala University, Uppsala, Sweden
| | - Andrei Alexsson
- Rheumatology, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
| | - Olafur Gudjonsson
- Neurosurgery, Department of Neuroscience, Uppsala University, Uppsala, Sweden
| | - Wei Liu
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Helge Rask-Andersen
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Mikael Karlsson
- Department of Engineering Sciences, Ångström Laboratory, Uppsala University, Uppsala, Sweden.
| | - Hao Li
- Otolaryngology and Head & Neck Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
27
|
Ballestero J, Recugnat M, Laudanski J, Smith KE, Jagger DJ, Gnansia D, McAlpine D. Reducing Current Spread by Use of a Novel Pulse Shape for Electrical Stimulation of the Auditory Nerve. Trends Hear 2015; 19:19/0/2331216515619763. [PMID: 26721928 PMCID: PMC4771040 DOI: 10.1177/2331216515619763] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Improving the electrode-neuron interface to reduce current spread between individual electrodes has been identified as one of the main objectives in the search for future improvements in cochlear-implant performance. Here, we address this problem by presenting a novel stimulation strategy that takes account of the biophysical properties of the auditory neurons (spiral ganglion neurons, SGNs) stimulated in electrical hearing. This new strategy employs a ramped pulse shape, where the maximum amplitude is achieved through a linear slope in the injected current. We present the theoretical framework that supports this new strategy and that suggests it will improve the modulation of SGNs’ activity by exploiting their sensitivity to the rising slope of current pulses. The theoretical consequence of this sensitivity to the slope is a reduction in the spread of excitation within the cochlea and, consequently, an increase in the neural dynamic range. To explore the impact of the novel stimulation method on neural activity, we performed in vitro recordings of SGNs in culture. We show that the stimulus efficacy required to evoke action potentials in SGNs falls as the stimulus slope decreases. This work lays the foundation for a novel, and more biomimetic, stimulation strategy with considerable potential for implementation in cochlear-implant technology.
Collapse
Affiliation(s)
| | | | | | - Katie E Smith
- Ear Institute, University College London, London, UK
| | | | | | | |
Collapse
|
28
|
Jorgensen LE, Messersmith JJ. Impact of Aging and Cognition on Hearing Assistive Technology Use. Semin Hear 2015; 36:162-74. [PMID: 27516716 PMCID: PMC4906296 DOI: 10.1055/s-0035-1555119] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Many factors go into appropriate recommendation and use of hearing assistive technology (HAT). The aging auditory system presents with its own complications and intricacies; there are many types of age-related hearing loss, and it is possible that the underlying cause of hearing loss can significantly impact the recommendations and performance with HATs. The audiologist should take into consideration peripheral and central auditory function when selecting HATs for the aging adult population as well as when selecting appropriate types of technology including personal sound amplification products, hearing aids, cochlear implants, and other assistive technology. The cognitive ability of the patient plays a central role in the recommendations of HAT. It is possible that the use of HATs could mitigate some of the effects of cognitive decline and thus should be considered as early as possible. Assessment of ability and appropriate recommendations are crucial to consistent use of HAT devices.
Collapse
Affiliation(s)
- Lindsey E. Jorgensen
- Department of Communication Sciences and Disorders, University of South Dakota, Vermillion, South Dakota
| | - Jessica J. Messersmith
- Department of Communication Sciences and Disorders, University of South Dakota, Vermillion, South Dakota
| |
Collapse
|
29
|
Scheperle RA, Abbas PJ. Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users. Ear Hear 2015; 36:441-53. [PMID: 25658746 PMCID: PMC4478147 DOI: 10.1097/aud.0000000000000144] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The ability to perceive speech is related to the listener's ability to differentiate among frequencies (i.e., spectral resolution). Cochlear implant (CI) users exhibit variable speech-perception and spectral-resolution abilities, which can be attributed in part to the extent of electrode interactions at the periphery (i.e., spatial selectivity). However, electrophysiological measures of peripheral spatial selectivity have not been found to correlate with speech perception. The purpose of this study was to evaluate auditory processing at the periphery and cortex using both simple and spectrally complex stimuli to better understand the stages of neural processing underlying speech perception. The hypotheses were that (1) by more completely characterizing peripheral excitation patterns than in previous studies, significant correlations with measures of spectral selectivity and speech perception would be observed, (2) adding information about processing at a level central to the auditory nerve would account for additional variability in speech perception, and (3) responses elicited with spectrally complex stimuli would be more strongly correlated with speech perception than responses elicited with spectrally simple stimuli. DESIGN Eleven adult CI users participated. Three experimental processor programs (MAPs) were created to vary the likelihood of electrode interactions within each participant. For each MAP, a subset of 7 of 22 intracochlear electrodes was activated: adjacent (MAP 1), every other (MAP 2), or every third (MAP 3). Peripheral spatial selectivity was assessed using the electrically evoked compound action potential (ECAP) to obtain channel-interaction functions for all activated electrodes (13 functions total). Central processing was assessed by eliciting the auditory change complex with both spatial (electrode pairs) and spectral (rippled noise) stimulus changes. Speech-perception measures included vowel discrimination and the Bamford-Kowal-Bench Speech-in-Noise test. Spatial and spectral selectivity and speech perception were expected to be poorest with MAP 1 (closest electrode spacing) and best with MAP 3 (widest electrode spacing). Relationships among the electrophysiological and speech-perception measures were evaluated using mixed-model and simple linear regression analyses. RESULTS All electrophysiological measures were significantly correlated with each other and with speech scores for the mixed-model analysis, which takes into account multiple measures per person (i.e., experimental MAPs). The ECAP measures were the best predictor. In the simple linear regression analysis on MAP 3 data, only the cortical measures were significantly correlated with speech scores; spectral auditory change complex amplitude was the strongest predictor. CONCLUSIONS The results suggest that both peripheral and central electrophysiological measures of spatial and spectral selectivity provide valuable information about speech perception. Clinically, it is often desirable to optimize performance for individual CI users. These results suggest that ECAP measures may be most useful for within-subject applications when multiple measures are performed to make decisions about processor options. They also suggest that if the goal is to compare performance across individuals based on a single measure, then processing central to the auditory nerve (specifically, cortical measures of discriminability) should be considered.
Collapse
Affiliation(s)
- Rachel A. Scheperle
- Department of Communication Sciences and Disorders, University of Iowa, Iowa
City, IA, USA
| | - Paul J. Abbas
- Department of Communication Sciences and Disorders, University of Iowa, Iowa
City, IA, USA
- Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, IA,
USA
| |
Collapse
|
30
|
Abstract
OBJECTIVES The primary goal of this study was to describe relationships between peripheral and central electrophysiologic measures of auditory processing within individual cochlear implant (CI) users. The distinctiveness of neural excitation patterns resulting from the stimulation of different electrodes, referred to as 'spatial selectivity,' was evaluated. The hypothesis was that if central representations of spatial interactions differed across participants semi-independently of peripheral input, then the within-subject relationships between peripheral and central electrophysiologic measures of spatial selectivity would reflect those differences. Cross-subject differences attributable to processing central to the auditory nerve may help explain why peripheral electrophysiologic measures of spatial selectivity have not been found to correlate with speech perception. DESIGN Eleven adults participated in this and a companion study. All were peri- or post-lingually deafened with more than 1 year of CI experience. Peripheral spatial selectivity was evaluated at 13 cochlear locations using 13 electrodes as probes to elicit electrically evoked compound action potentials (ECAPs). Masker electrodes were varied across the array for each probe electrode to derive channel-interaction functions. The same 13 electrodes were used to evaluate spatial selectivity represented at a cortical level. Electrode pairs were stimulated sequentially to elicit the auditory change complex (ACC), an obligatory cortical potential suggestive of discrimination. For each participant, the relationship between ECAP channel-interaction functions (quantified as channel-separation indices) and ACC N1-P2 amplitudes was modeled using the saturating exponential function y = a * (1-e). Both a and b coefficients were varied using a least-squares approach to optimize the fits. RESULTS Electrophysiologic measures of spatial selectivity assessed at peripheral (ECAP) and central (ACC) levels varied across participants. The results indicate that differences in ACC amplitudes observed across participants for the same stimulus conditions were not solely the result of differences in peripheral excitation patterns. This finding supports the view that processing at multiple points along the auditory neural pathway from the periphery to the cortex may vary across individuals with different etiologies and auditory experiences. CONCLUSIONS The distinctiveness of neural excitation resulting from electrical stimulation varies across CI recipients, and this variability was observed in both peripheral and cortical electrophysiologic measures. The ACC amplitude differences observed across participants were partially independent from differences in peripheral neural spatial selectivity. These findings are clinically relevant because they imply that there may be limits (1) to the predictive ability of peripheral measures and (2) in the extent to which improving the selectivity of electrical stimulation via programming options (e.g., current focusing/steering) will result in more specific central neural excitation patterns or will improve speech perception.
Collapse
Affiliation(s)
- Rachel A. Scheperle
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, IA, USA
| | - Paul J. Abbas
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, IA, USA
- Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, IA, USA
| |
Collapse
|
31
|
Pfingst BE, Zhou N, Colesa DJ, Watts MM, Strahl SB, Garadat SN, Schvartz-Leyzac KC, Budenz CL, Raphael Y, Zwolan TA. Importance of cochlear health for implant function. Hear Res 2015; 322:77-88. [PMID: 25261772 PMCID: PMC4377117 DOI: 10.1016/j.heares.2014.09.009] [Citation(s) in RCA: 102] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Revised: 08/14/2014] [Accepted: 09/16/2014] [Indexed: 01/17/2023]
Abstract
Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled .
Collapse
Affiliation(s)
- Bryan E Pfingst
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA.
| | - Ning Zhou
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA; East Carolina University, Greenville, NC, USA
| | - Deborah J Colesa
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA
| | - Melissa M Watts
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA
| | | | - Soha N Garadat
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA; The University of Jordan, Amman, Jordan
| | | | - Cameron L Budenz
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA
| | - Yehoash Raphael
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA
| | - Teresa A Zwolan
- Department of Otolaryngology, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
32
|
Cosentino S, Gaudrain E, Deeks J, Carlyon R. Multistage nonlinear optimization to recover neural activation patterns from evoked compound action potentials of cochlear implant users. IEEE Trans Biomed Eng 2015; 63:833-40. [DOI: 10.1109/tbme.2015.2476373] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
33
|
Goehring JL, Neff DL, Baudhuin JL, Hughes ML. Pitch ranking, electrode discrimination, and physiological spread of excitation using current steering in cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 136:3159. [PMID: 25480063 PMCID: PMC4257956 DOI: 10.1121/1.4900634] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Revised: 10/07/2014] [Accepted: 10/08/2014] [Indexed: 06/04/2023]
Abstract
The first objective of this study was to determine whether adaptive pitch-ranking and electrode-discrimination tasks with cochlear-implant (CI) recipients produce similar results for perceiving intermediate "virtual-channel" pitch percepts using current steering. Previous studies have not examined both behavioral tasks in the same subjects with current steering. A second objective was to determine whether a physiological metric of spatial separation using the electrically evoked compound action potential spread-of-excitation (ECAP SOE) function could predict performance in the behavioral tasks. The metric was the separation index (Σ), defined as the difference in normalized amplitudes between two adjacent ECAP SOE functions, summed across all masker electrodes. Eleven CII or 90 K Advanced Bionics (Valencia, CA) recipients were tested using pairs of electrodes from the basal, middle, and apical portions of the electrode array. The behavioral results, expressed as d', showed no significant differences across tasks. There was also no significant effect of electrode region for either task. ECAP Σ was not significantly correlated with pitch ranking or electrode discrimination for any of the electrode regions. Therefore, the ECAP separation index is not sensitive enough to predict perceptual resolution of virtual channels.
Collapse
Affiliation(s)
- Jenny L Goehring
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| | - Donna L Neff
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| | - Jacquelyn L Baudhuin
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| | - Michelle L Hughes
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| |
Collapse
|
34
|
Abbas PJ, Brown CJ. Assessment of responses to cochlear implant stimulation at different levels of the auditory pathway. Hear Res 2014; 322:67-76. [PMID: 25445817 DOI: 10.1016/j.heares.2014.10.011] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Revised: 09/22/2014] [Accepted: 10/21/2014] [Indexed: 11/30/2022]
Abstract
This paper reviews characteristics of both the electrically evoked compound action potential (ECAP) and analogous measures of cortically evoked responses (CAEP) to electrical stimulation in cochlear implant users. Specific comparisons are made between the two levels of processing for measures of threshold, growth of responses with increasing stimulus level, changes in stimulation electrode and, finally, in temporal response properties. The results are interpreted in a context that ECAPs primarily reflect the characteristics of the electrode-neural interface for an individual ear. CAEPs clearly are dependent on those peripheral responses but also reflect differences in central processing among individual implant users. The potential applicability of combined measures in clinical situations is discussed. This article is part of a Special Issue entitled <Lasker Award>.
Collapse
Affiliation(s)
- Paul J Abbas
- Department of Communication Sciences and Disorders, Department of Otolaryngology, Head and Neck Surgery, University of Iowa, Iowa City, I A, USA.
| | - Carolyn J Brown
- Department of Communication Sciences and Disorders, Department of Otolaryngology, Head and Neck Surgery, University of Iowa, Iowa City, I A, USA
| |
Collapse
|
35
|
Won JH, Humphrey EL, Yeager KR, Martinez AA, Robinson CH, Mills KE, Johnstone PM, Moon IJ, Woo J. Relationship among the physiologic channel interactions, spectral-ripple discrimination, and vowel identification in cochlear implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 136:2714-25. [PMID: 25373971 DOI: 10.1121/1.4895702] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The hypothesis of this study was that broader patterns of physiological channel interactions in the local region of the cochlea are associated with poorer spectral resolution in the same region. Electrically evoked compound action potentials (ECAPs) were measured for three to six probe electrodes per subject to examine the channel interactions in different regions across the electrode array. To evaluate spectral resolution at a confined location within the cochlea, spectral-ripple discrimination (SRD) was measured using narrowband ripple stimuli with the bandwidth spanning five electrodes: Two electrodes apical and basal to the ECAP probe electrode. The relationship between the physiological channel interactions, spectral resolution in the local cochlear region, and vowel identification was evaluated. Results showed that (1) there was within- and across-subject variability in the widths of ECAP channel interaction functions and in narrowband SRD performance, (2) significant correlations were found between the widths of the ECAP functions and narrowband SRD thresholds, and between mean bandwidths of ECAP functions averaged across multiple probe electrodes and broadband SRD performance across subjects, and (3) the global spectral resolution reflecting the entire electrode array, not the local region, predicts vowel identification.
Collapse
Affiliation(s)
- Jong Ho Won
- University of Tennessee Health Science Center, Knoxville, Tennessee 37996
| | | | - Kelly R Yeager
- University of Tennessee Health Science Center, Knoxville, Tennessee 37996
| | - Alexis A Martinez
- University of Tennessee Health Science Center, Knoxville, Tennessee 37996
| | - Camryn H Robinson
- University of Tennessee Health Science Center, Knoxville, Tennessee 37996
| | - Kristen E Mills
- University of Tennessee Health Science Center, Knoxville, Tennessee 37996
| | - Patti M Johnstone
- University of Tennessee Health Science Center, Knoxville, Tennessee 37996
| | - Il Joon Moon
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, 135-710, South Korea
| | - Jihwan Woo
- Department of Biomedical Engineering, University of Ulsan, Ulsan, 680-749, South Korea
| |
Collapse
|
36
|
|
37
|
Goehring JL, Neff DL, Baudhuin JL, Hughes ML. Pitch ranking, electrode discrimination, and physiological spread-of-excitation using Cochlear's dual-electrode mode. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 136:715-727. [PMID: 25096106 PMCID: PMC4144258 DOI: 10.1121/1.4884881] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2013] [Revised: 06/10/2014] [Accepted: 06/12/2014] [Indexed: 06/03/2023]
Abstract
This study compared pitch ranking, electrode discrimination, and electrically evoked compound action potential (ECAP) spatial excitation patterns for adjacent physical electrodes (PEs) and the corresponding dual electrodes (DEs) for newer-generation Cochlear devices (Cochlear Ltd., Macquarie, New South Wales, Australia). The first goal was to determine whether pitch ranking and electrode discrimination yield similar outcomes for PEs and DEs. The second goal was to determine if the amount of spatial separation among ECAP excitation patterns (separation index, Σ) between adjacent PEs and the PE-DE pairs can predict performance on the psychophysical tasks. Using non-adaptive procedures, 13 subjects completed pitch ranking and electrode discrimination for adjacent PEs and the corresponding PE-DE pairs (DE versus each flanking PE) from the basal, middle, and apical electrode regions. Analysis of d' scores indicated that pitch-ranking and electrode-discrimination scores were not significantly different, but rather produced similar levels of performance. As expected, accuracy was significantly better for the PE-PE comparison than either PE-DE comparison. Correlations of the psychophysical versus ECAP Σ measures were positive; however, not all test/region correlations were significant across the array. Thus, the ECAP separation index is not sensitive enough to predict performance on behavioral tasks of pitch ranking or electrode discrimination for adjacent PEs or corresponding DEs.
Collapse
Affiliation(s)
- Jenny L Goehring
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| | - Donna L Neff
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| | - Jacquelyn L Baudhuin
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| | - Michelle L Hughes
- Boys Town National Research Hospital, Lied Learning and Technology Center, 425 North 30th Street, Omaha, Nebraska 68131
| |
Collapse
|
38
|
Fielden CA, Kluk K, McKay CM. Place specificity of monopolar and tripolar stimuli in cochlear implants: the influence of residual masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:4109-4123. [PMID: 23742363 DOI: 10.1121/1.4803909] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This experiment investigated whether place specificity of neural activity evoked by cochlear implant stimulation is improved in tripolar compared to monopolar mode using a forward masking protocol addressing some limitations of previous methods of measurement and analysis. The amount of residual masking (masking remaining at long masker-probe delays) was also measured, and its potential influence on the specificity measures was evaluated. The masker stimulus comprised equally loud interleaved mono- or tripolar stimulation on two electrodes equidistant from a central probe electrode in an apical and basal direction, reducing the influence of off-site listening. The effect of masker-probe distance on the threshold shift of the tripolar probe was analyzed to derive a measure of place specificity. On average, tripolar maskers were more place specific than monopolar maskers, although the mean effect was small. There was no significant effect of masker level on specificity or on the differences observed between modes. The mean influence of residual masking on normalized masking functions was similar for the two modes and, therefore, did not influence the comparison of specificity between the modes. However, variability in amount of residual masking was observed between subjects, and therefore should be considered in forward masking studies that compare place specificity across subjects.
Collapse
Affiliation(s)
- Claire A Fielden
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom.
| | | | | |
Collapse
|
39
|
Current steering with partial tripolar stimulation mode in cochlear implants. J Assoc Res Otolaryngol 2012; 14:213-31. [PMID: 23250685 DOI: 10.1007/s10162-012-0366-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2012] [Accepted: 12/02/2012] [Indexed: 11/27/2022] Open
Abstract
The large spread of excitation is a major cause of poor spectral resolution for cochlear implant (CI) users. Partial tripolar (pTP) mode has been proposed to reduce current spread by returning an equally distributed fraction (0.5 × σ) of current to two flanking electrodes and the rest to an extra-cochlear ground. This study tested the efficacy of incorporating current steering into pTP mode to add spectral channels. Different proportions of current [α × σ and (1 - α) × σ] were returned to the basal and apical flanking electrodes respectively to shape the electric field. Loudness and pitch perception with α from 0 to 1 in steps of 0.1 was simulated with a computational model of CI stimulation and tested on the apical, middle, and basal electrodes of six CI subjects. The highest σ allowing for full loudness growth within the implant compliance limit was chosen for each main electrode. Pitch ranking was measured between pairs of loudness-balanced steered pTP stimuli with an α interval of 0.1 at the most comfortable level. Results demonstrated that steered pTP stimuli with α around 0.5 required more current to achieve equal loudness than those with α around 0 or 1, maybe due to more focused excitation patterns. Subjects usually perceived decreasing pitches as α increased from 0 to 1, somewhat consistent with the apical shift of the center of gravity of excitation pattern in the model. Pitch discrimination was not better with α around 0.5 than with α around 0 or 1, except for some subjects and electrodes. For three subjects with better pitch discrimination, about half of the pitch ranges of two adjacent main electrodes overlapped with each other in steered pTP mode. These results suggest that current steering with focused pTP mode may improve spectral resolution and pitch perception with CIs.
Collapse
|
40
|
Spread of excitation and channel interaction in single- and dual-electrode cochlear implant stimulation. Ear Hear 2012; 33:367-76. [PMID: 22048258 DOI: 10.1097/aud.0b013e318234efd5] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To determine how simultaneous dual-electrode stimulation (DES) can be optimized for the individual patient to deliver better sound quality and speech recognition. DES was compared with single-electrode stimulation (SES) with respect to the site of stimulation (X) in the cochlea, the spread of excitation (SOE), and channel interaction. Second, it was investigated whether the number of intermediate pitches created with DES can be predicted from SOE, channel interaction measures, current distribution in the cochlea, or distance of the electrode to the medial wall. DESIGN Twelve users of the HiRes90K cochlear implant with HiFocus1J electrode were randomly selected to participate in this study. Electrode contacts were selected based on their location in the cochlea as determined by multislice computed tomography, viz. 120 degrees (basal), 240 degrees (middle), and 360 degrees (apical) from the round window. The number of intermediate pitches with simultaneous DES was assessed with a three-alternative forced choice pitch discrimination experiment. The channel interactions between two single-electrode contacts and two DES pairs were determined with a threshold detection experiment (three-alternative forced choice). The eCAP-based SOE method with fixed probe and variable masker was used to determine the location of the neurons responding to a single-electrode contact or dual-electrode contact stimulus. Furthermore, the intracochlear electrical fields were determined with the Electrical Field Imaging tool kit. RESULTS DES was not different from SES in terms of channel interaction and SOE. The X of DES was 0.54 electrode contacts more basal compared with SES stimulation, which was not different from the predicted shift of 0.5. SOE and current distribution were significantly different for the three locations in the cochlea but showed no correlation with the number of perceivable pitches. A correlation was found between channel interaction and the number of intermediate pitches along the array within a patient, not between patients. CONCLUSION SES and DES are equivalent with regard to SOE and channel interaction. The excitation site of DES has the predicted displacement compared with the excitation region induced by the neighboring single-electrode contact. Unfortunately, no predictor for the number of intermediate pitches was found.
Collapse
|
41
|
Preliminary results of the relationship between the binaural interaction component of the electrically evoked auditory brainstem response and interaural pitch comparisons in bilateral cochlear implant recipients. Ear Hear 2012; 33:57-68. [PMID: 21730858 DOI: 10.1097/aud.0b013e31822519ef] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE : The purpose of this study was to investigate the relationship between electrophysiologic measures of the binaural interaction component (BIC) of the electrically evoked auditory brainstem response and psychophysical measures of interaural pitch comparisons in Nucleus bilateral cochlear implant users. DESIGN : Data were collected for 10 postlingually deafened adult cochlear implant users. Each subject conducted an interaural pitch-comparison task using a biphasic pulse train with a pulse rate of 1000 pulses per second (pps) at high stimulation levels. Stimuli were presented in a two-interval, two-alternative forced-choice procedure with roving current variations. A subgroup of four subjects repeated the task at low stimulation levels. BICs were measured using loudness balanced, biphasic current pulses presented at a rate of 19.9 pps for each subject by pairing the electrode 12 (out of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The BIC was measured at high stimulation levels in 10 subjects and at low stimulation levels in 7 subjects. Because of differences in stimulation rate used in BIC measures and interaural pitch comparisons, the actual stimulation levels were different in these two measures. The relationship between BIC responses and results of interaural pitch comparisons was evaluated for each of the individual subjects and at the group level. Evaluation was carried out separately for results obtained at high and low stimulation levels. RESULTS : There was no significant correlation between results of BIC measures and interaural pitch comparisons on either the individual or group levels. Lower stimulation level did not improve the relationship between these two measures. CONCLUSIONS : No significant correlations between psychophysical measures of interaural pitch comparisons and electrophysiologic measures of the BIC of the electrically evoked auditory brainstem response were found. The lack of correlation may be attributed to methods used to quantify the data, small number of subjects retested at low stimulation levels, and central processing components involved in the interaural pitch-comparison task.
Collapse
|
42
|
McKay CM. Forward masking as a method of measuring place specificity of neural excitation in cochlear implants: a review of methods and interpretation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 131:2209-24. [PMID: 22423717 DOI: 10.1121/1.3683248] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
This paper reviews the psychophysical forward masking methods that have been used to investigate place specificity in cochlear implantees. These experiments are relevant for investigating whether the individual variability in outcomes for people using the same device can be explained by individual variations in frequency resolution or whether place specificity is affected by different modes of stimulation (such as bipolar, monopolar or tripolar) in the same person. Unfortunately, there has been no consensus about the methods used to derive electrical forward masking functions, or in the way that they are interpreted in relation to place specificity. Here, the different methods are critically examined to provide insight into the optimal methods that should be used to measure and interpret spatial forward masking functions in electric hearing. It is shown that, in order to separate the temporal effects of masking decay from the place-specificity information, different analyses of the functions are needed depending on whether a fixed-probe or fixed-masker method is employed. The effects of unit of measurement on specificity measures and the effects of subject listening strategy on the forward masked functions are also discussed.
Collapse
Affiliation(s)
- Colette M McKay
- School of Psychological Sciences, University of Manchester, Oxford Road, Manchester, M33 3GH, United Kingdom.
| |
Collapse
|
43
|
van der Beek FB, Briaire JJ, Frijns JH. Effects of parameter manipulations on spread of excitation measured with electrically-evoked compound action potentials. Int J Audiol 2012; 51:465-74. [DOI: 10.3109/14992027.2011.653446] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
44
|
Zhu Z, Tang Q, Zeng FG, Guan T, Ye D. Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation. Hear Res 2012; 283:45-58. [PMID: 22138630 PMCID: PMC3277661 DOI: 10.1016/j.heares.2011.11.005] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Revised: 10/28/2011] [Accepted: 11/08/2011] [Indexed: 11/21/2022]
Abstract
Sharp spatial selectivity is critical to auditory performance, particularly in pitch-related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear-implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear-implant performance.
Collapse
Affiliation(s)
- Ziyan Zhu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | | | | | | | | |
Collapse
|
45
|
Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration. Ear Hear 2011; 32:436-44. [PMID: 21178633 DOI: 10.1097/aud.0b013e3181ff33ab] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVES The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. DESIGN Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. RESULTS Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial tripolar configurations. The Wave V amplitude growth functions with increasing stimulus level showed the predicted effect of shallower growth for the partial tripolar than for the monopolar configuration, but this was observed only for the low-threshold channels. In contrast, high-threshold channels showed the opposite effect; steeper growth functions were seen for the partial tripolar configuration. CONCLUSIONS These results suggest that behavioral thresholds or EABRs measured with a restricted stimulus can be used to identify potentially impaired cochlear implant channels. Channels having high thresholds and steep growth functions would likely not activate the appropriate spatially restricted region of the cochlea, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.
Collapse
|
46
|
Azadpour M, McKay CM. A psychophysical method for measuring spatial resolution in cochlear implants. J Assoc Res Otolaryngol 2011; 13:145-57. [PMID: 22002609 DOI: 10.1007/s10162-011-0294-z] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2011] [Accepted: 09/14/2011] [Indexed: 11/28/2022] Open
Abstract
A novel psychophysical method was developed for assessing spatial resolution in cochlear implants. Spectrally flat and spectrally peaked pulse train stimuli were generated by interleaving pulses on 11 electrodes. Spectrally flat stimuli used loudness-balanced currents and the spectrally peaked stimuli had a single spatial ripple with the current of the middle electrode raised to create a peak while the currents on two electrodes equally spaced at variable distance from the peak electrode were reduced to create valleys. The currents on peak and valley electrodes were adjusted to balance the overall loudness with the spectrally flat stimulus, while keeping the currents on flanking electrodes fixed. The psychometric functions obtained from percent correct discrimination of peaked and flat stimuli versus the distance between peak and valley electrodes were used to quantify spatial resolution for each of the eight subjects. The ability to resolve the spatial ripple correlated strongly with current level difference limens measured on the peak electrode. The results were consistent with a hypothesis that a factor other than spread of excitation (such as neural response variance) might underlie much of the variability in spatial resolution. Resolution ability was not correlated with phoneme recognition in quiet or sentence recognition in quiet and background noise, consistent with a hypothesis that implantees rely on cues other than fine spectral detail to identify speech, perhaps because this detail is poorly accessible or unreliable.
Collapse
Affiliation(s)
- Mahan Azadpour
- Audiology & Deafness Research Group, School of Psychological Sciences, University of Manchester, Manchester, M13 9PL, UK.
| | | |
Collapse
|
47
|
Electrically evoked compound action potential measures for virtual channels versus physical electrodes. Ear Hear 2011; 32:323-30. [PMID: 21187752 DOI: 10.1097/aud.0b013e3182008c56] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The number of distinct pitch percepts for cochlear implant (CI) listeners is somewhat limited by the number of physical electrodes in the array. Newer-generation CIs have the capability to potentially increase this number by stimulating areas of the cochlea between the physical electrodes. Currently, this is achieved by electrically coupling adjacent electrodes or by simultaneously activating two electrodes with independent current sources (i.e., current steering). Presumably, either type of dual-electrode stimulation will generate neural excitation patterns that are intermediate to those generated by either physical electrode alone (henceforth termed virtual channel). However, it is not clear whether virtual-channel stimulation yields neural recruitment patterns with similar shapes and rates of growth as compared with each physical electrode alone. The purpose of this study was to compare basic electrically evoked compound action potential (ECAP) measures for physical electrodes and virtual channels to determine whether properties of the respective excitation patterns were similar. DESIGN Data were collected for 12 adult CI recipients (six Nucleus Freedom CI24RE, two Advanced Bionics HiResolution 90K, and four Advanced Bionics CII). ECAP responses were measured for a set of three adjacent physical electrodes and two corresponding intermediate virtual channels (e.g., physical electrodes 4, 5, and 6 and virtual channels 4 + 5 and 5 + 6) at three positions along the electrode array (basal, middle, and apical). Virtual channels for Nucleus subjects were produced via electrical coupling of adjacent electrode pairs (dual-electrode mode). For Advanced Bionics subjects, virtual channels were produced via simultaneous, in-phase stimulation of adjacent electrode pairs with 50% of the total current delivered to each electrode in the pair. Specific ECAP measures were as follows: (1) threshold and slope of the input/output functions, (2) amplitude for a masker-probe interval of 1500 μsecs (measure of refractory recovery), and (3) relative location of spread of excitation (SOE) functions among virtual channels and adjacent physical electrodes. Measures for virtual channels were compared with those for the flanking physical electrodes using a multivariate analysis of variance. RESULTS There were no statistically significant differences between physical electrodes and virtual channels for ECAP thresholds, slope of the input/output function, or refractory recovery. On average, SOE functions for the virtual channels were spatially located approximately halfway between SOE functions for the adjacent physical electrodes. CONCLUSIONS Results from this study suggest that virtual channels produce neural recruitment patterns with properties similar to those elicited by the adjacent physical electrodes.
Collapse
|
48
|
Effect of stimulus and recording parameters on spatial spread of excitation and masking patterns obtained with the electrically evoked compound action potential in cochlear implants. Ear Hear 2011; 31:679-92. [PMID: 20505513 DOI: 10.1097/aud.0b013e3181e1d19e] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Spread of excitation within the cochlea in response to electrical stimulation can be measured with the electrically evoked compound action potential (ECAP). Different spread of excitation measurement techniques have been reported in the literature. One method uses a fixed stimulus location while varying the recording electrode along the length of the implanted array. This results in a relatively coarse estimate of spatial spread (SS) along the cochlea. Another method uses a forward-masking paradigm to evaluate the relative overlap of stimulated neural populations between electrodes. Both the probe and recording electrodes are fixed in location while a masker stimulus is systematically applied across electrodes. This method, which yields a more precise estimate of spatial excitation patterns, is termed spatial masking (SM). Five experiments were conducted to examine potential effects of stimulus and/or recording parameters on SS and SM patterns. Experiment 1 examined whether SS patterns were systematically broader than SM patterns across electrodes and subjects. Experiments 2 and 3 evaluated the effects of stimulus level on SS and SM patterns, respectively, to determine whether increased stimulus level systematically resulted in broader patterns. Experiment 4 evaluated whether recording electrode location affected SM patterns, and Experiment 5 evaluated whether SM patterns varied significantly across repeated trials within a test session. DESIGN Data were collected for 27 ears in 26 adult and teenage subjects (N = 6 ears with Advanced Bionics CII, N = 8 ears with Advanced Bionics HiRes 90K, N = 10 ears with Nucleus 24R[CS], N = 3 ears with Nucleus 24RE[CA] Freedom). A standard forward-masking subtraction paradigm was used for all ECAP measures. For SS patterns, the masker and probe were fixed on the same electrode at the same level while the recording electrode varied across the remaining electrodes in the array. For SM patterns, the probe and recording locations were fixed while the masker location varied across all electrodes except the recording electrode. RESULTS In experiment 1, SS patterns were broader than SM patterns. Subjects with Advanced Bionics devices exhibited relatively broad patterns for both measures, whereas Nucleus subjects typically exhibited narrower SM functions relative to SS functions. In experiments 2 and 3, there was a significant effect of stimulus level on the spread of both SS and SM patterns in roughly one-third of measures in each experiment. In experiment 4, there was a significant effect of recording electrode location on the width/spread of SM patterns for only 11.5% of comparisons. In experiment 5, there were no significant differences in SM amplitudes across repeated trials for 94% of comparisons, which suggests that ECAP measures are highly robust within a test session. CONCLUSIONS Results showed that SS functions were generally broader than SM functions, which suggests that SS measures reflect volume conduction of the ECAP response along the length of the cochlea. Differences in the spread of SM functions across devices are likely due to differences in modiolar proximity between the respective electrode array designs. Stimulus level had a more significant effect on the spread of SM functions than recording electrode location. Finally, ECAP measures were shown to be highly stable across repeated measurements within a test session; however, repeatability was not assessed across sessions or over extended time intervals.
Collapse
|
49
|
Effects of stimulation level and electrode pairing on the binaural interaction component of the electrically evoked auditory brain stem response. Ear Hear 2010; 31:457-70. [PMID: 20418771 DOI: 10.1097/aud.0b013e3181d5d9bf] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The purpose of this study was to investigate the effects of stimulation level and electrode pairing on the binaural interaction component (BIC) of the electrically evoked auditory brain stem response (EABR) in Nucleus cochlear implant (CI) users. DESIGN Ten postlingually deafened adult CI users participated in this study. EABRs were measured using loudness balanced, biphasic current pulses presented in the left monaural, right monaural, and bilateral stimulation conditions. BICs were computed based on measures of the EABR obtained for each subject by pairing the electrode 12 (of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The effect of stimulation level on the amplitude of the BIC was investigated by measuring growth functions of the BIC from six subjects. The effect of electrode pairing on the amplitude of the BIC was studied at high stimulation levels in 10 subjects and at low stimulation levels in seven subjects. The high stimulation level was chosen as the 90% point of the subject's dynamic range (DR) or the highest stimulation level in which the electrophysiologic recordings were not contaminated by muscle artifacts. The low stimulation level was chosen as a level that was 10% point of subject's DR higher than the BIC threshold for six of these seven subjects. For one subject, BIC thresholds were not available and the low stimulation level was referred to the 70% point of subject's DR. RESULTS BICs were successfully recorded from all 11 interaural electrode pairs for a majority of subjects tested at both stimulation levels. BIC amplitudes increased with stimulation level. The effect of stimulation level on latencies of the BIC was less robust. At high stimulation levels, BIC amplitudes did not change significantly as the stimulating electrode used in the left ear was systematically varied. When low stimulation levels were used, BIC amplitude was maximal for interaural electrode pairs with similar intracochlear positions and decreased when the offset between interaural electrodes increased. CONCLUSIONS This study demonstrates that stimulation level affects amplitudes of the BIC response. It is possible to record the BIC of the EABR in bilateral CI users even from interaural electrode pairs that have large interaural offsets. This finding suggests that when high-level stimuli are used, there is a broad pattern of current spread within the two cochleae. At lower stimulation levels, the spread of excitation within the cochlea is reduced making the effect of electrode pairing on the amplitude of the BIC more pronounced.
Collapse
|
50
|
Srinivasan AG, Landsberger DM, Shannon RV. Current focusing sharpens local peaks of excitation in cochlear implant stimulation. Hear Res 2010; 270:89-100. [PMID: 20850513 DOI: 10.1016/j.heares.2010.09.004] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2010] [Revised: 08/19/2010] [Accepted: 09/08/2010] [Indexed: 10/19/2022]
Abstract
Cochlear implant (CI) users' spectral resolution is limited by the number of implanted electrodes, interactions between the electrodes, and the underlying neural population. Current steering has been proposed to increase the number of spectral channels beyond the number of physical electrodes, however, electric field interactions may limit CI users' access to current-steered virtual channels (VCs). Current focusing (e.g tripolar stimulation) has been proposed to reduce current spread and thereby reduce interactions. In this study, current steering and current focusing were combined in a four-electrode stimulation pattern, i.e quadrupolar virtual channels (QPVCs). The spread of excitation was measured and compared between QPVC and Monopolar VC (MPVC) stimuli using a forward masking task. Results showed a sharper peak in the excitation pattern and reduced spread of masking for QPVC stimuli. Results from the forward masking study were compared with a previous study measuring VC discrimination ability and showed a weak relationship between spread of excitation and VC discriminability. The results suggest that CI signal processing strategies that utilize both current steering and current focusing might increase CI users' functional spectral resolution by transmitting more channels and reducing channel interactions.
Collapse
Affiliation(s)
- Arthi G Srinivasan
- Department of Communication and Auditory Neuroscience, House Ear Institute, Los Angeles, CA 90057, USA.
| | | | | |
Collapse
|