251
|
Richardson K, Langridge D, Dixit SM, Ruotolo BT. An Improved Calibration Approach for Traveling Wave Ion Mobility Spectrometry: Robust, High-Precision Collision Cross Sections. Anal Chem 2021; 93:3542-3550. [PMID: 33555172 DOI: 10.1021/acs.analchem.0c04948] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The combination of ion-mobility (IM) separation with mass spectrometry (MS) has impacted global measurement efforts in areas ranging from food analysis to drug discovery. Reasons for the broad adoption of IM-MS include its significantly increased peak capacity, duty-cycle, and ability to reconstruct fragmentation data in parallel, all of which greatly enable the analyses of complex mixtures. More fundamentally, however, measurements of ion-gas molecule collision cross sections (CCSs) are used to support compound identification and quantitation efforts as well as study the structures of large biomolecules. As the first commercialized form of IM-MS, Traveling Wave Ion Mobility (TWIM) devices are operated at low pressures (∼3 mbar) and voltages, are relatively short (∼25 cm), and separate ions on a timescale of tens of milliseconds. These qualities make TWIM ideally suited for hybridization with MS. Owing to the complicated motion of ions in TWIM devices, however, IM transit times must be calibrated to enable CCS measurements. Applicability of these calibrations has hitherto been restricted to primarily singly charged small molecules and some classes of large, multiply charged ions under a significantly narrower range of instrument conditions. Here, we introduce and extensively characterize a dramatically improved TWIM calibration methodology. Using over 2500 experimental TWIM data sets, covering ions that span over 3.5 orders of magnitude of molecular mass, we demonstrate robust calibrations for a significantly expanded range of instrument conditions, thereby opening up new analytical application areas and enabling the expansion of high-precision CCS measurements for both existing and next-generation TWIM instrumentation.
Collapse
Affiliation(s)
- K Richardson
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, United Kingdom
| | - D Langridge
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, United Kingdom
| | - S M Dixit
- Department of Chemistry, University of Michigan, University Ave., Ann Arbor, Michigan 48109, United States
| | - B T Ruotolo
- Department of Chemistry, University of Michigan, University Ave., Ann Arbor, Michigan 48109, United States
| |
Collapse
|
252
|
Mitra R, Gadkari VV, Meinen BA, van Mierlo CPM, Ruotolo BT, Bardwell JCA. Mechanism of the small ATP-independent chaperone Spy is substrate specific. Nat Commun 2021; 12:851. [PMID: 33558474 PMCID: PMC7870927 DOI: 10.1038/s41467-021-21120-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 01/08/2021] [Indexed: 11/17/2022] Open
Abstract
ATP-independent chaperones are usually considered to be holdases that rapidly bind to non-native states of substrate proteins and prevent their aggregation. These chaperones are thought to release their substrate proteins prior to their folding. Spy is an ATP-independent chaperone that acts as an aggregation inhibiting holdase but does so by allowing its substrate proteins to fold while they remain continuously chaperone bound, thus acting as a foldase as well. The attributes that allow such dual chaperoning behavior are unclear. Here, we used the topologically complex protein apoflavodoxin to show that the outcome of Spy's action is substrate specific and depends on its relative affinity for different folding states. Tighter binding of Spy to partially unfolded states of apoflavodoxin limits the possibility of folding while bound, converting Spy to a holdase chaperone. Our results highlight the central role of the substrate in determining the mechanism of chaperone action.
Collapse
Affiliation(s)
- Rishav Mitra
- Howard Hughes Medical Institute, University of Michigan, Ann Arbor, MI, USA
- Department of Molecular, Cellular, and Developmental Biology, University of Michigan, Ann Arbor, MI, USA
| | - Varun V Gadkari
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
| | - Ben A Meinen
- Howard Hughes Medical Institute, University of Michigan, Ann Arbor, MI, USA
- Department of Molecular, Cellular, and Developmental Biology, University of Michigan, Ann Arbor, MI, USA
| | | | | | - James C A Bardwell
- Howard Hughes Medical Institute, University of Michigan, Ann Arbor, MI, USA.
- Department of Molecular, Cellular, and Developmental Biology, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|
253
|
Ross DH, Xu L. Determination of drugs and drug metabolites by ion mobility-mass spectrometry: A review. Anal Chim Acta 2021; 1154:338270. [PMID: 33736803 DOI: 10.1016/j.aca.2021.338270] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 01/25/2021] [Accepted: 01/27/2021] [Indexed: 01/04/2023]
Abstract
Ion mobility-mass spectrometry (IM-MS) has gained increased applications in the characterization and identification of drugs and drug metabolites, largely owning to the complementary separation of analyte ions based on their gas-phase size and shape in the IM dimension in addition to their mass-to-charge ratios. In this review, we discuss recent advances in such applications. We first introduce various types of IM techniques, focusing on those that allow the measurement of collision cross section (CCS), the physical property of an ion that reflects its gas-phase size and shape. Next, we discuss the IM-MS landscape of the large chemical space of drugs and multimodal distributions of certain drugs in IM separation due to the presence of protomers. We then review drug metabolism reactions and discuss the application of IM-MS in separation and identification of isomeric drug metabolites. Subsequently, we discuss various approaches to generate theoretical and predicted CCS data, including theory-based calculation methods and data-driven prediction models, and currently available resources on these approaches. Finally, current limitations and future directions of application of IM-MS are discussed.
Collapse
Affiliation(s)
- Dylan H Ross
- Department of Medicinal Chemistry, University of Washington, 1959, NE Pacific Street, HSB H-172, Seattle, WA, USA
| | - Libin Xu
- Department of Medicinal Chemistry, University of Washington, 1959, NE Pacific Street, HSB H-172, Seattle, WA, USA.
| |
Collapse
|
254
|
Mlynek F, Himmelsbach M, Buchberger W, Klampfl CW. A fast-screening approach for the tentative identification of drug-related metabolites from three non-steroidal anti-inflammatory drugs in hydroponically grown edible plants by HPLC-drift-tube-ion-mobility quadrupole time-of-flight mass spectrometry. Electrophoresis 2021; 42:482-489. [PMID: 33274757 PMCID: PMC7898722 DOI: 10.1002/elps.202000292] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 11/30/2020] [Accepted: 12/01/2020] [Indexed: 01/15/2023]
Abstract
The (tentative) identification of unknown drug-related phase II metabolites in plants upon drug uptake remains a challenging task despite improved analytical instrument performance. To broaden the knowledge of possible drug metabolization, a fast-screening approach for the tentative identification of drug-related phase II metabolites is presented in this work. Therefore, an in silico database for the three non-steroidal anti-inflammatory drugs (ketoprofen, mefenamic acid, and naproxen) and a sub-group of their theoretical phase II metabolites (based on combinations with glucose, glucuronic acid, and malonic acid) was created. Next, the theoretical exact masses (protonated species and ammonia adducts) were calculated and used as precursor ions in an autoMS/MS measurement method. The applicability of this workflow was tested on the example of eleven edible plants, which were hydroponically grown in solutions containing the respective drug at a concentration level of 20 mg/L. For the three drugs investigated this led to the tentative identification of 41 metabolites (some of them so far not described in this context), such as combinations of hydroxylated mefenamic acid with up to four glucose units or hydroxylated mefenamic acid with two glucose and three malonic acid units.
Collapse
Affiliation(s)
- Franz Mlynek
- Institute of Analytical ChemistryJohannes Kepler UniversityLinzAustria
| | | | | | | |
Collapse
|
255
|
Sastre Toraño J, Aizpurua‐Olaizola O, Wei N, Li T, Unione L, Jiménez‐Osés G, Corzana F, Somovilla VJ, Falcon‐Perez JM, Boons G. Identification of Isomeric N-Glycans by Conformer Distribution Fingerprinting using Ion Mobility Mass Spectrometry. Chemistry 2021; 27:2149-2154. [PMID: 33047840 PMCID: PMC7898647 DOI: 10.1002/chem.202004522] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Indexed: 12/14/2022]
Abstract
Glycans possess unparalleled structural complexity arising from chemically similar monosaccharide building blocks, configurations of anomeric linkages and different branching patterns, potentially giving rise to many isomers. This level of complexity is one of the main reasons that identification of exact glycan structures in biological samples still lags behind that of other biomolecules. Here, we introduce a methodology to identify isomeric N-glycans by determining gas phase conformer distributions (CDs) by measuring arrival time distributions (ATDs) using drift-tube ion mobility spectrometry-mass spectrometry. Key to the approach is the use of a range of well-defined synthetic glycans that made it possible to investigate conformer distributions in the gas phase of isomeric glycans in a systematic manner. In addition, we have computed CD fingerprints by molecular dynamics (MD) simulation, which compared well with experimentally determined CDs. It supports that ATDs resemble conformational populations in the gas phase and offer the prospect that such an approach can contribute to generating a library of CCS distributions (CCSDs) for structure identification.
Collapse
Affiliation(s)
- Javier Sastre Toraño
- Department of Chemical Biology and Drug DiscoveryUtrecht Institute for Pharmaceutical SciencesUtrecht UniversityUtrechtThe Netherlands
| | - Oier Aizpurua‐Olaizola
- Department of Chemical Biology and Drug DiscoveryUtrecht Institute for Pharmaceutical SciencesUtrecht UniversityUtrechtThe Netherlands
- Exosomes LabCIC bioGUNE, CIBERehdDerioSpain
| | - Na Wei
- The University of GeorgiaComplex Carbohydrate Research CenterAthensGAUSA
| | - Tiehai Li
- The University of GeorgiaComplex Carbohydrate Research CenterAthensGAUSA
| | - Luca Unione
- Department of Chemical Biology and Drug DiscoveryUtrecht Institute for Pharmaceutical SciencesUtrecht UniversityUtrechtThe Netherlands
| | - Gonzalo Jiménez‐Osés
- Center for Cooperative Research in Biosciences (CIC bioGUNEBasque Research and Technology Alliance (BRTA)Bizkaia Technology Park, Building 801A48160DerioSpain
| | - Francisco Corzana
- Departamento de Química, Centro de Investigación en Síntesis QuímicaUniversidad de La Rioja26006LogroñoSpain
| | - Victor J. Somovilla
- Department of Chemical Biology and Drug DiscoveryUtrecht Institute for Pharmaceutical SciencesUtrecht UniversityUtrechtThe Netherlands
| | | | - Geert‐Jan Boons
- Department of Chemical Biology and Drug DiscoveryUtrecht Institute for Pharmaceutical SciencesUtrecht UniversityUtrechtThe Netherlands
- The University of GeorgiaComplex Carbohydrate Research CenterAthensGAUSA
| |
Collapse
|
256
|
Norman C, McKirdy B, Walker G, Dugard P, NicDaéid N, McKenzie C. Large-scale evaluation of ion mobility spectrometry for the rapid detection of synthetic cannabinoid receptor agonists in infused papers in prisons. Drug Test Anal 2021; 13:644-663. [PMID: 33058556 DOI: 10.1002/dta.2945] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/08/2020] [Accepted: 10/09/2020] [Indexed: 11/10/2022]
Abstract
Synthetic cannabinoid receptor agonists (SCRAs), colloquially known as "spice," are commonly used in prisons and enter establishments via the mail in the form of infused papers. Many prisons use benchtop ion mobility spectroscopy (IMS) instruments to screen mail and seized materials for the presence of SCRAs and other controlled substances. The selectivity and sensitivity of Rapiscan Itemiser® 3E and Itemiser® 4DN Ion Trap Mobility Spectroscopy™ (ITMS™) systems were evaluated using 21 SCRA reference standards. Some differences in the SCRA reduced mobility (K0 ) values were observed between this study and those reported previously using IMS detection systems, particularly for cumyl and quinolinyl SCRAs (e.g., 5F-PB-22, Cumyl-4CN-BINACA, and 5F-Cumyl-PEGACLONE), although this was found to have little effect at an operational level. Operational reliability of the systems was evaluated by analyzing 392 paper and card samples with known drug content. ITMS™ system results (e.g., detect or nondetect) were in agreement with gas chromatography-mass spectrometry (GC-MS) analysis in up to 95% of samples tested. Overall, this study found the ITMS™ systems tested to be effective instruments when deployed for the rapid detection of SCRA-infused papers. Used effectively and with up-to-date substance libraries, they will help reduce the supply of SCRAs into prisons and identify emerging threats as they arise. Several emerging SCRAs (5F-MPP-PICA, 5F-EMB-PICA, and 4F-MDMB-BICA) were detected for the first time in Scottish prisons between May and August 2020 as a result of routine monitoring, and all were detected using the ITMS™ systems tested.
Collapse
Affiliation(s)
- Caitlyn Norman
- Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK
| | - Brian McKirdy
- HMP Inverness, Scottish Prison Service, Inverness, UK
| | - Gillian Walker
- Public Protection Unit, Scottish Prison Service, Edinburgh, UK
| | - Pat Dugard
- Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK
| | - Niamh NicDaéid
- Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK
| | - Craig McKenzie
- Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK
| |
Collapse
|
257
|
Rampler E, Abiead YE, Schoeny H, Rusz M, Hildebrand F, Fitz V, Koellensperger G. Recurrent Topics in Mass Spectrometry-Based Metabolomics and Lipidomics-Standardization, Coverage, and Throughput. Anal Chem 2021; 93:519-545. [PMID: 33249827 PMCID: PMC7807424 DOI: 10.1021/acs.analchem.0c04698] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Evelyn Rampler
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
- Vienna Metabolomics Center (VIME), University of Vienna, Althanstraße 14, 1090 Vienna, Austria
- University of Vienna, Althanstraße 14, 1090 Vienna, Austria
| | - Yasin El Abiead
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
| | - Harald Schoeny
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
| | - Mate Rusz
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
- Institute of Inorganic
Chemistry, University of Vienna, Währinger Straße 42, 1090 Vienna, Austria
| | - Felina Hildebrand
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
| | - Veronika Fitz
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
| | - Gunda Koellensperger
- Department of Analytical
Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria
- Vienna Metabolomics Center (VIME), University of Vienna, Althanstraße 14, 1090 Vienna, Austria
- University of Vienna, Althanstraße 14, 1090 Vienna, Austria
| |
Collapse
|
258
|
Masike K, Stander MA, de Villiers A. Recent applications of ion mobility spectrometry in natural product research. J Pharm Biomed Anal 2021; 195:113846. [PMID: 33422832 DOI: 10.1016/j.jpba.2020.113846] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 12/08/2020] [Accepted: 12/08/2020] [Indexed: 12/15/2022]
Abstract
Ion mobility spectrometry (IMS) is a rapid separation technique capable of extracting complementary structural information to chromatography and mass spectrometry (MS). IMS, especially in combination with MS, has experienced inordinate growth in recent years as an analytical technique, and elicited intense interest in many research fields. In natural product analysis, IMS shows promise as an additional tool to enhance the performance of analytical methods used to identify promising drug candidates. Potential benefits of the incorporation of IMS into analytical workflows currently used in natural product analysis include the discrimination of structurally similar secondary metabolites, improving the quality of mass spectral data, and the use of mobility-derived collision cross-section (CCS) values as an additional identification criterion in targeted and untargeted analyses. This review aims to provide an overview of the application of IMS to natural product analysis over the last six years. Instrumental aspects and the fundamental background of IMS will be briefly covered, and recent applications of the technique for natural product analysis will be discussed to demonstrate the utility of the technique in this field.
Collapse
Affiliation(s)
- Keabetswe Masike
- Department of Biochemistry, Stellenbosch University, Private Bag X1, Matieland, 7602, South Africa
| | - Maria A Stander
- Department of Biochemistry, Stellenbosch University, Private Bag X1, Matieland, 7602, South Africa; Central Analytical Facility, Stellenbosch University, Private Bag X1, Matieland, 7602, South Africa
| | - André de Villiers
- Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland, 7602, South Africa.
| |
Collapse
|
259
|
Conant CR, Attah IK, Garimella SVB, Nagy G, Bilbao A, Smith RD, Ibrahim YM. Evaluation of Waveform Profiles for Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:225-236. [PMID: 33126794 PMCID: PMC8170696 DOI: 10.1021/jasms.0c00282] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Structures for lossless ion manipulations (SLIM) have recently enabled a powerful implementation of traveling wave ion mobility spectrometry (TWIMS) for ultrahigh resolution separations; however, experimental parameters have not been optimized, and potential significant gains may be feasible. Most TWIMS separations have utilized square-shaped waveforms applied by time-dependent voltage stepping across repeating sets of electrodes, but alternative waveforms may provide further improvements to resolution. Here, we characterize five waveforms (including square and sine) in terms of their transmission efficiency, IMS resolution, and resolving power, and explore the effects of TW amplitude and speed on the performance of each. We found, consistent with previous work, separations were generally improved with higher TW amplitudes, moderately improved by lower speeds (limited by ion "surfing" with the waves), and found decreases in signal intensity at the extremes of operating conditions. The triangle and asymmetric "ramp forward" shaped profiles were found to provide modestly greater resolution and resolving power, an observation we tentatively attribute to their relatively uniform fields and minimal low-field regions.
Collapse
Affiliation(s)
- Christopher R Conant
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Isaac K Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Gabe Nagy
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Aivett Bilbao
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| |
Collapse
|
260
|
Rose BS, Leaptrot KL, Harris RA, Sherrod SD, May JC, McLean JA. High Confidence Shotgun Lipidomics Using Structurally Selective Ion Mobility-Mass Spectrometry. Methods Mol Biol 2021; 2306:11-37. [PMID: 33954937 PMCID: PMC10127451 DOI: 10.1007/978-1-0716-1410-5_2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Ion mobility (IM) is a gas phase separation strategy that can either supplement or serve as a high-throughput alternative to liquid chromatography (LC) in shotgun lipidomics. Incorporating the IM dimension in untargeted lipidomics workflows can help resolve isomeric lipids, and the collision cross section (CCS) values obtained from the IM measurements can provide an additional molecular descriptor to increase lipid identification confidence. This chapter provides a broad overview of an untargeted ion mobility-mass spectrometry (IM-MS) workflow using a commercial drift tube ion mobility-quadrupole-time-of-flight mass spectrometer (IM-QTOF) for high confidence lipidomics.
Collapse
Affiliation(s)
- Bailey S Rose
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Katrina L Leaptrot
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Rachel A Harris
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Stacy D Sherrod
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Jody C May
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - John A McLean
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA.
- Department of Chemistry, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
261
|
Maillard JF, Le Maître J, Rüger CP, Ridgeway M, Thompson CJ, Paupy B, Hubert-Roux M, Park M, Afonso C, Giusti P. Structural analysis of petroporphyrins from asphaltene by trapped ion mobility coupled with Fourier transform ion cyclotron resonance mass spectrometry. Analyst 2021; 146:4161-4171. [PMID: 34047731 DOI: 10.1039/d1an00140j] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Molecular characterization of compounds present in highly complex mixtures such as petroleum is proving to be one of the main analytical challenges. Heavy fractions, such as asphaltenes, exhibit immense molecular and isomeric complexity. Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) with its unequalled resolving power, mass accuracy and dynamic range can address the isobaric complexity. Nevertheless, isomers remain largely inaccessible. Therefore, another dimension of separation is required. Recently, ion mobility mass spectrometry has revealed great potential for isomer description. In this study, the combination of trapped ion mobility and Fourier transform ion cyclotron resonance mass spectrometry (TIMS-FTICR) is used to obtain information on the structural features and isomeric diversity of vanadium petroporphyrins present in heavy petroleum fractions. The ion mobility spectra provided information on the isomeric diversity of the different classes of porphyrins. The determination of the collision cross section (CCS) from the peak apex allows us to hypothesize about the structural aspects of the petroleum molecules. In addition, the ion mobility signal full width at half maximum (FWHM) was used as a measure for isomeric diversity. Finally, theoretical CCS determinations were conducted first on core structures and then on alkylated petroporphyrins taking advantage of the linear correlation between the CCS and the alkylation level. This allowed the proposal of putative structures in agreement with the experimental results. The authors believe that the presented workflow will be useful for the structural prediction of real unknowns in highly complex mixtures.
Collapse
Affiliation(s)
- Julien F Maillard
- Normandie Université, COBRA, UMR 6014 et FR 3038, Université de Rouen, INSA de Rouen-Normandie, CNRS, IRCOF, Mont Saint Aignan Cedex, France. and International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France
| | - Johann Le Maître
- Normandie Université, COBRA, UMR 6014 et FR 3038, Université de Rouen, INSA de Rouen-Normandie, CNRS, IRCOF, Mont Saint Aignan Cedex, France. and TOTAL Refining & Chemicals, Total Research & Technology Gonfreville, BP 27, 76700 Harfleur, France and International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France
| | - Christopher P Rüger
- International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France and Joint Mass Spectrometry Centre/Chair of Analytical Chemistry, University of Rostock, 18059 Rostock, Germany and Department Life, Light & Matter (LLM), University of Rostock, 18051 Rostock, Germany
| | | | | | - Benoit Paupy
- TOTAL Refining & Chemicals, Total Research & Technology Gonfreville, BP 27, 76700 Harfleur, France and International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France
| | - Marie Hubert-Roux
- Normandie Université, COBRA, UMR 6014 et FR 3038, Université de Rouen, INSA de Rouen-Normandie, CNRS, IRCOF, Mont Saint Aignan Cedex, France. and International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France
| | | | - Carlos Afonso
- Normandie Université, COBRA, UMR 6014 et FR 3038, Université de Rouen, INSA de Rouen-Normandie, CNRS, IRCOF, Mont Saint Aignan Cedex, France. and International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France
| | - Pierre Giusti
- Normandie Université, COBRA, UMR 6014 et FR 3038, Université de Rouen, INSA de Rouen-Normandie, CNRS, IRCOF, Mont Saint Aignan Cedex, France. and TOTAL Refining & Chemicals, Total Research & Technology Gonfreville, BP 27, 76700 Harfleur, France and International Joint Laboratory - iC2MC: Complex Matrices Molecular Characterization, TRTG, BP 27, 76700 Harfleur, France
| |
Collapse
|
262
|
|
263
|
Delgado-Povedano MDM, de Villiers A, Hann S, Causon T. Identity confirmation of anthocyanins in berries by LC-DAD-IM-QTOFMS. Electrophoresis 2020; 42:473-481. [PMID: 33188545 PMCID: PMC7898798 DOI: 10.1002/elps.202000274] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 10/26/2020] [Accepted: 10/30/2020] [Indexed: 12/11/2022]
Abstract
Rugged analytical methods for the screening and identity confirmation of anthocyanins require a dedicated sample preparation, chromatographic setup, and the reliable generation of multiple identification points to confirm identity against the wide range of phenolic compounds typically present in food, beverage, and plant material samples. To this end, combinations of spectroscopic and mass spectrometric detection are frequently employed for this application to provide higher confidence in the absence of authentic standards. In the present work, low‐field drift tube ion mobility (DTIM) separation is evaluated for this task using a LC–DAD–DTIM–QTOFMS method. DTIM‐MS allows accurate determination of collision cross sections (DTCCS) for all analysed compounds as well as a precise alignment tool for reconciling fragment and precursor ions in data independent acquisition mode. The presented approach thereby allows for an anthocyanin screening method taking true advantage of all dimensions of the analytical platform: relative retention (RPLC), UV/VIS absorption spectrum, accurate mass, DTCCSN2, and confirmed high‐resolution fragment ions. From the analysis of authentic standards and several berry samples primarily from the Vaccinium genus, Level 1 confirmation data for six anthocyanins from the cyanidin family, and Level 2 confirmation for a further 29 anthocyanins confirmed in berry samples is provided. The method and accompanying dataset provided as part of this work provides a means to develop anthocyanin screening methods using the ion mobility dimension as an additional alignment and filtering parameter in data independent analysis acquisition across any LC–IM–MS platform.
Collapse
Affiliation(s)
- María Del Mar Delgado-Povedano
- Department of Analytical Chemistry, University of Córdoba, Córdoba, Spain.,Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences, Vienna, Austria
| | - André de Villiers
- Department of Chemistry and Polymer Science, Stellenbosch University, Stellenbosch, South Africa
| | - Stephan Hann
- Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences, Vienna, Austria
| | - Tim Causon
- Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences, Vienna, Austria
| |
Collapse
|
264
|
Gadkari VV, Ramírez CR, Vallejo DD, Kurulugama RT, Fjeldsted JC, Ruotolo BT. Enhanced Collision Induced Unfolding and Electron Capture Dissociation of Native-like Protein Ions. Anal Chem 2020; 92:15489-15496. [PMID: 33166123 PMCID: PMC7861131 DOI: 10.1021/acs.analchem.0c03372] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Native ion mobility-mass spectrometry (IM-MS) is capable of revealing much that remains unknown within the structural proteome, promising such information on refractory protein targets. Here, we report the development of a unique drift tube IM-MS (DTIM-MS) platform, which combines high-energy source optics for improved collision induced unfolding (CIU) experiments and an electromagnetostatic cell for electron capture dissociation (ECD). We measured a series of high precision collision cross section (CCS) values for protein and protein complex ions ranging from 6-1600 kDa, exhibiting an average relative standard deviation (RSD) of 0.43 ± 0.20%. Furthermore, we compare our CCS results to previously reported DTIM values, finding strong agreement across similarly configured instrumentation (average RSD of 0.82 ± 0.73%), and systematic differences for DTIM CCS values commonly used to calibrate traveling-wave IM separators (-3% average RSD). Our CIU experiments reveal that the modified DTIM-MS instrument described here achieves enhanced levels of ion activation when compared with any previously reported IM-MS platforms, allowing for comprehensive unfolding of large multiprotein complex ions as well as interplatform CIU comparisons. Using our modified DTIM instrument, we studied two protein complexes. The enhanced CIU capabilities enable us to study the gas phase stability of the GroEL 7-mer and 14-mer complexes. Finally, we report CIU-ECD experiments for the alcohol dehydrogenase tetramer, demonstrating improved sequence coverage by combining ECD fragmentation integrated over multiple CIU intermediates. Further improvements for such native top-down sequencing experiments were possible by leveraging IM separation, which enabled us to separate and analyze CID and ECD fragmentation simultaneously.
Collapse
Affiliation(s)
- Varun V Gadkari
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, Michigan 48109, United States
| | - Carolina Rojas Ramírez
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, Michigan 48109, United States
| | - Daniel D Vallejo
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, Michigan 48109, United States
| | - Ruwan T Kurulugama
- Agilent Technologies, 5301 Stevens Creek Blvd, Santa Clara, California 98051, United States
| | - John C Fjeldsted
- Agilent Technologies, 5301 Stevens Creek Blvd, Santa Clara, California 98051, United States
| | - Brandon T Ruotolo
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
265
|
Rivera ES, Djambazova KV, Neumann EK, Caprioli RM, Spraggins JM. Integrating ion mobility and imaging mass spectrometry for comprehensive analysis of biological tissues: A brief review and perspective. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4614. [PMID: 32955134 PMCID: PMC8211109 DOI: 10.1002/jms.4614] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 06/27/2020] [Accepted: 07/02/2020] [Indexed: 05/02/2023]
Abstract
Imaging mass spectrometry (IMS) technologies are capable of mapping a wide array of biomolecules in diverse cellular and tissue environments. IMS has emerged as an essential tool for providing spatially targeted molecular information due to its high sensitivity, wide molecular coverage, and chemical specificity. One of the major challenges for mapping the complex cellular milieu is the presence of many isomers and isobars in these samples. This challenge is traditionally addressed using orthogonal liquid chromatography (LC)-based analysis, though, common approaches such as chromatography and electrophoresis are not able to be performed at timescales that are compatible with most imaging applications. Ion mobility offers rapid, gas-phase separations that are readily integrated with IMS workflows in order to provide additional data dimensionality that can improve signal-to-noise, dynamic range, and specificity. Here, we highlight recent examples of ion mobility coupled to IMS and highlight their importance to the field.
Collapse
Key Words
- IMS
- desorption electrospray ionization, DESI
- drift tube ion mobility spectrometry, DTIMS
- high-field asymmetric waveform ion mobility, FAIMS
- imaging mass spectrometry
- infrared matrix-assisted laser desorption electrospray ionization, IR-MALDESI
- ion mobility
- laser ablation electrospray ionization, LAESI
- lipids
- liquid extraction surface analysis, LESA
- liquid microjunction, (LMJ)
- matrix-assisted laser desorption electrospray ionization, MALDI
- metabolites
- proteins
- tissue analysis
- trapped ion mobility spectrometry, TIMS
- travelling wave ion mobility spectrometry, TWIMS
Collapse
Affiliation(s)
- Emilio S. Rivera
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
| | - Katerina V. Djambazova
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN 37235, USA
| | - Elizabeth K. Neumann
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
| | - Richard M. Caprioli
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN 37235, USA
- Department of Pharmacology, Vanderbilt University, 2220 Pierce Avenue, Nashville, TN 37232, USA
- Department of Medicine, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
| | - Jeffrey M. Spraggins
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, TN 37205, USA
- Mass Spectrometry Research Center, Vanderbilt University, 465 21 Ave S #9160, Nashville, TN 37235, USA
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, TN 37235, USA
| |
Collapse
|
266
|
Chen C, Tabrizchi M, Li H. Ion gating in ion mobility spectrometry: Principles and advances. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116100] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
267
|
Luo YS, Aly NA, McCord J, Strynar MJ, Chiu WA, Dodds JN, Baker ES, Rusyn I. Rapid Characterization of Emerging Per- and Polyfluoroalkyl Substances in Aqueous Film-Forming Foams Using Ion Mobility Spectrometry-Mass Spectrometry. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:15024-15034. [PMID: 33176098 PMCID: PMC7719402 DOI: 10.1021/acs.est.0c04798] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Aqueous film-forming foams (AFFF) are mixtures formulated with numerous hydrocarbon- and fluoro-containing surfactants. AFFF use leads to environmental releases of unknown per- and polyfluoroalkyl substances (PFAS). AFFF composition is seldom disclosed, and their use elicits concerns from both regulatory agencies and the public because PFAS are persistent in the environment and potentially associated with adverse health effects. In this study, we demonstrate the use of coupled liquid chromatography, ion mobility spectrometry, and mass spectrometry (LC-IMS-MS) to rapidly characterize both known and unknown PFAS in AFFF. Ten AFFF formulations from seven brands were analyzed using LC-IMS-MS in both negative and positive ion modes. Untargeted analysis of the formulations was followed by feature identification of PFAS-like features utilizing database matching, mass defect and homologous series evaluation, and MS/MS fragmentation experiments. Across the tested AFFF formulations, we identified 33 homologous series; only ten of these homologous series have been previously reported. Among tested AFFF, the FireStopper (n = 85) contained the greatest number of PFAS-like features and Phos-Check contained zero. This work demonstrates that LC-IMS-MS-enabled untargeted analysis of complex formulations, followed by feature identification using data-processing algorithms, can be used for rapid exposure characterization of known and putative PFAS during fire suppression-related contamination events.
Collapse
Affiliation(s)
- Yu-Syuan Luo
- Department of Veterinary Integrative Biosciences, Texas A&M University, College Station, Texas 77845-3424, United States
| | - Noor A Aly
- Department of Veterinary Integrative Biosciences, Texas A&M University, College Station, Texas 77845-3424, United States
| | - James McCord
- Center for Environmental Measurement and Modeling, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711, United States
| | - Mark J Strynar
- Center for Environmental Measurement and Modeling, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711, United States
| | - Weihsueh A Chiu
- Department of Veterinary Integrative Biosciences, Texas A&M University, College Station, Texas 77845-3424, United States
| | - James N Dodds
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695,United States
| | - Erin S Baker
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695,United States
| | - Ivan Rusyn
- Department of Veterinary Integrative Biosciences, Texas A&M University, College Station, Texas 77845-3424, United States
| |
Collapse
|
268
|
Baksi A, Schneider EK, Weis P, Chakraborty I, Fuhr O, Lebedkin S, Parak WJ, Kappes MM. Linear Size Contraction of Ligand Protected Ag 29 Clusters by Substituting Ag with Cu. ACS NANO 2020; 14:15064-15070. [PMID: 33089986 DOI: 10.1021/acsnano.0c05082] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
There are only a few examples of atomically precise, ligand protected, bimetallic coinage metal clusters in which molecular structure remains essentially unchanged over a wide composition range starting from the corresponding homometallic species. Such model systems are particularly useful to study the dynamics of alloy formation on the nanoscale. Here we demonstrate the unusual reactivity of solvated metalloid-superatom Ag29(BDT)12(PPh3)4 (BDT = 1,3 benzenedithiol) clusters toward semiconducting Cu12S6(DPPPT)4 (DPPPT = bis(diphenylphosphino)pentane) clusters as an efficient way to exchange multiple copper atoms into the atomically precise silver clusters without changing overall the structure type. Concentration-dependent UV-vis absorption and online mass spectrometry shows that 14 Cu atoms can be exchanged into the silver cluster. Beyond the 14 Cu atom exchange, the cluster degrades to smaller thiolates. Information on cluster structures is obtained from high-resolution ion mobility mass spectrometry, which shows a linear decrease in collision cross section (CCS) with each Ag/Cu exchanged. Several isomeric structures are calculated by density functional theory (DFT), and their calculated collision cross sections are used to identify the most stable isomers for each Ag/Cu exchange product. Ag/Cu exchange is essentially limited to the cluster surface/shell. The core appears not to be involved.
Collapse
Affiliation(s)
- Ananya Baksi
- Institute of Nanotechnology, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen, Germany
- Institute of Physical Chemistry, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Erik Karsten Schneider
- Institute of Physical Chemistry, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Patrick Weis
- Institute of Physical Chemistry, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Indranath Chakraborty
- Center for Hybrid Nanostructures (CHyN), University of Hamburg, 22761 Hamburg, Germany
| | - Olaf Fuhr
- Institute of Nanotechnology, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen, Germany
- Karlsruher Nano-Micro-Facility (KNMF), Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen, Germany
| | - Sergei Lebedkin
- Institute of Nanotechnology, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen, Germany
- Institute of Physical Chemistry, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Wolfgang J Parak
- Center for Hybrid Nanostructures (CHyN), University of Hamburg, 22761 Hamburg, Germany
| | - Manfred M Kappes
- Institute of Nanotechnology, Karlsruhe Institute of Technology, 76344 Eggenstein-Leopoldshafen, Germany
- Institute of Physical Chemistry, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| |
Collapse
|
269
|
Li A, Conant CR, Zheng X, Bloodsworth KJ, Orton DJ, Garimella SVB, Attah IK, Nagy G, Smith RD, Ibrahim YM. Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations. Anal Chem 2020; 92:14976-14982. [PMID: 33136380 DOI: 10.1021/acs.analchem.0c02829] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling wave ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20, 25, and 30 V0-p). The calibration errors for the three calibrant sets (Agilent tuning mixture, polyalanine, and one assembled in-house) showed negligible differences using a sine-shaped TW waveform. Calibration errors were all within 1-2% of the drift tube ion mobility spectrometry (DTIMS) measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh-resolution multipass (long path length) SLIM TWIMS separations demonstrated improved CCS calibration for phospholipid and bile acid isomers.
Collapse
Affiliation(s)
- Ailin Li
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Christopher R Conant
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Xueyun Zheng
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Kent J Bloodsworth
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Daniel J Orton
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Isaac K Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Gabe Nagy
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| |
Collapse
|
270
|
Lieblein T, Zangl R, Martin J, Hoffmann J, Hutchison MJ, Stark T, Stirnal E, Schrader T, Schwalbe H, Morgner N. Structural rearrangement of amyloid-β upon inhibitor binding suppresses formation of Alzheimer's disease related oligomers. eLife 2020; 9:59306. [PMID: 33095161 PMCID: PMC7682991 DOI: 10.7554/elife.59306] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 10/22/2020] [Indexed: 01/24/2023] Open
Abstract
The formation of oligomers of the amyloid-β peptide plays a key role in the onset of Alzheimer's disease. We describe herein the investigation of disease-relevant small amyloid-β oligomers by mass spectrometry and ion mobility spectrometry, revealing functionally relevant structural attributes. In particular, we can show that amyloid-β oligomers develop in two distinct arrangements leading to either neurotoxic oligomers and fibrils or non-toxic amorphous aggregates. Comprehending the key-attributes responsible for those pathways on a molecular level is a pre-requisite to specifically target the peptide's tertiary structure with the aim to promote the emergence of non-toxic aggregates. Here, we show for two fibril inhibiting ligands, an ionic molecular tweezer and a hydrophobic peptide that despite their different interaction mechanisms, the suppression of the fibril pathway can be deduced from the disappearance of the corresponding structure of the first amyloid-β oligomers.
Collapse
Affiliation(s)
- Tobias Lieblein
- JW Goethe-University, Institute of Physical and Theoretical Chemistry, Frankfurt, Germany
| | - Rene Zangl
- JW Goethe-University, Institute of Physical and Theoretical Chemistry, Frankfurt, Germany
| | - Janosch Martin
- JW Goethe-University, Institute of Physical and Theoretical Chemistry, Frankfurt, Germany
| | - Jan Hoffmann
- JW Goethe-University, Institute of Physical and Theoretical Chemistry, Frankfurt, Germany
| | - Marie J Hutchison
- JW Goethe-University, Institute for Organic Chemistry and Chemical Biology and Center for Biomolecular Magnetic Resonance, Frankfurt am Main, Germany
| | - Tina Stark
- JW Goethe-University, Institute for Organic Chemistry and Chemical Biology and Center for Biomolecular Magnetic Resonance, Frankfurt am Main, Germany
| | - Elke Stirnal
- JW Goethe-University, Institute for Organic Chemistry and Chemical Biology and Center for Biomolecular Magnetic Resonance, Frankfurt am Main, Germany
| | - Thomas Schrader
- University of Duisburg-Essen, Institute of Organic Chemistry, Essen, Germany
| | - Harald Schwalbe
- JW Goethe-University, Institute for Organic Chemistry and Chemical Biology and Center for Biomolecular Magnetic Resonance, Frankfurt am Main, Germany
| | - Nina Morgner
- JW Goethe-University, Institute of Physical and Theoretical Chemistry, Frankfurt, Germany
| |
Collapse
|
271
|
Drouin N, van Mever M, Zhang W, Tobolkina E, Ferre S, Servais AC, Gou MJ, Nyssen L, Fillet M, Lageveen-Kammeijer GS, Nouta J, Chetwynd AJ, Lynch I, Thorn JA, Meixner J, Lößner C, Taverna M, Liu S, Tran NT, Francois Y, Lechner A, Nehmé R, Al Hamoui Dit Banni G, Nasreddine R, Colas C, Lindner HH, Faserl K, Neusüß C, Nelke M, Lämmerer S, Perrin C, Bich-Muracciole C, Barbas C, Gonzálvez Á, Guttman A, Szigeti M, Britz-McKibbin P, Kroezen Z, Shanmuganathan M, Nemes P, Portero EP, Hankemeier T, Codesido S, González-Ruiz V, Rudaz S, Ramautar R. Capillary Electrophoresis-Mass Spectrometry at Trial by Metabo-Ring: Effective Electrophoretic Mobility for Reproducible and Robust Compound Annotation. Anal Chem 2020; 92:14103-14112. [PMID: 32961048 PMCID: PMC7581015 DOI: 10.1021/acs.analchem.0c03129] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/22/2020] [Indexed: 12/15/2022]
Abstract
Capillary zone electrophoresis-mass spectrometry (CE-MS) is a mature analytical tool for the efficient profiling of (highly) polar and ionizable compounds. However, the use of CE-MS in comparison to other separation techniques remains underrepresented in metabolomics, as this analytical approach is still perceived as technically challenging and less reproducible, notably for migration time. The latter is key for a reliable comparison of metabolic profiles and for unknown biomarker identification that is complementary to high resolution MS/MS. In this work, we present the results of a Metabo-ring trial involving 16 CE-MS platforms among 13 different laboratories spanning two continents. The goal was to assess the reproducibility and identification capability of CE-MS by employing effective electrophoretic mobility (μeff) as the key parameter in comparison to the relative migration time (RMT) approach. For this purpose, a representative cationic metabolite mixture in water, pretreated human plasma, and urine samples spiked with the same metabolite mixture were used and distributed for analysis by all laboratories. The μeff was determined for all metabolites spiked into each sample. The background electrolyte (BGE) was prepared and employed by each participating lab following the same protocol. All other parameters (capillary, interface, injection volume, voltage ramp, temperature, capillary conditioning, and rinsing procedure, etc.) were left to the discretion of the contributing laboratories. The results revealed that the reproducibility of the μeff for 20 out of the 21 model compounds was below 3.1% vs 10.9% for RMT, regardless of the huge heterogeneity in experimental conditions and platforms across the 13 laboratories. Overall, this Metabo-ring trial demonstrated that CE-MS is a viable and reproducible approach for metabolomics.
Collapse
Affiliation(s)
- Nicolas Drouin
- Division
of Systems Biomedicine and Pharmacology, Leiden Academic Centre for
Drug Research, Leiden University, 2311 G Leiden, The Netherlands
| | - Marlien van Mever
- Division
of Systems Biomedicine and Pharmacology, Leiden Academic Centre for
Drug Research, Leiden University, 2311 G Leiden, The Netherlands
| | - Wei Zhang
- Division
of Systems Biomedicine and Pharmacology, Leiden Academic Centre for
Drug Research, Leiden University, 2311 G Leiden, The Netherlands
| | - Elena Tobolkina
- School
of Pharmaceutical Sciences, University of
Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Institute
of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
| | - Sabrina Ferre
- School
of Pharmaceutical Sciences, University of
Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Institute
of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
| | - Anne-Catherine Servais
- Laboratory
for the Analysis of Medicines, Center for Interdisciplinary Research
on Medicines (CIRM), University of Liège, Avenue Hippocrate 15, B-4000 Liège, Belgium
| | - Marie-Jia Gou
- Laboratory
for the Analysis of Medicines, Center for Interdisciplinary Research
on Medicines (CIRM), University of Liège, Avenue Hippocrate 15, B-4000 Liège, Belgium
| | - Laurent Nyssen
- Laboratory
for the Analysis of Medicines, Center for Interdisciplinary Research
on Medicines (CIRM), University of Liège, Avenue Hippocrate 15, B-4000 Liège, Belgium
- Department
of Clinical Chemistry, Center for Interdisciplinary Research on Medicines
(CIRM), University of Liège, Avenue Hippocrate 15, B-4000 Liège, Belgium
| | - Marianne Fillet
- Laboratory
for the Analysis of Medicines, Center for Interdisciplinary Research
on Medicines (CIRM), University of Liège, Avenue Hippocrate 15, B-4000 Liège, Belgium
| | | | - Jan Nouta
- Leiden University
Medical Center, Center for Proteomics
and Metabolomics, 2300 RC Leiden, The Netherlands
| | - Andrew J. Chetwynd
- School
of Geography Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, U.K.
| | - Iseult Lynch
- School
of Geography Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, U.K.
| | - James A. Thorn
- AB
Sciex UK Ltd, Phoenix House, Lakeside Drive, Warrington, Cheshire WA1 1RX, U.K.
| | - Jens Meixner
- Agilent
Technologies R&D and Marketing GmbH & Co. KG, Hewlett-Packard-Straße 8, 76337 Waldbronn, Germany
| | | | - Myriam Taverna
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 92296 Châtenay-Malabry, France
- Institut Universitaire de France, 1 Rue Descartes, 75231 CEDEX 05 Paris, France
| | - Sylvie Liu
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 92296 Châtenay-Malabry, France
| | - N. Thuy Tran
- Université Paris-Saclay, CNRS, Institut Galien Paris-Saclay, 92296 Châtenay-Malabry, France
| | - Yannis Francois
- Laboratoire
de Spectromètrie de Masse des Interactions et des Systémes
(LSMIS) UMR 7140 (Unistra-CNRS), Université
de Strasbourg, 4 Rue Blaise Pascal, 67081 CEDEX Strasbourg, France
| | - Antony Lechner
- Laboratoire
de Spectromètrie de Masse des Interactions et des Systémes
(LSMIS) UMR 7140 (Unistra-CNRS), Université
de Strasbourg, 4 Rue Blaise Pascal, 67081 CEDEX Strasbourg, France
| | - Reine Nehmé
- Institut
de Chimie Organique et Analytique (ICOA), CNRS FR 2708 - UMR 7311, Université d’Orléans, 45067 Orléans, France
| | - Ghassan Al Hamoui Dit Banni
- Institut
de Chimie Organique et Analytique (ICOA), CNRS FR 2708 - UMR 7311, Université d’Orléans, 45067 Orléans, France
| | - Rouba Nasreddine
- Institut
de Chimie Organique et Analytique (ICOA), CNRS FR 2708 - UMR 7311, Université d’Orléans, 45067 Orléans, France
| | - Cyril Colas
- Institut
de Chimie Organique et Analytique (ICOA), CNRS FR 2708 - UMR 7311, Université d’Orléans, 45067 Orléans, France
- Centre de Biophysique Moléculaire,
CNRS-Université
d’Orléans, UPR 4311, 45071 CEDEX 2 Orléans, France
| | - Herbert H. Lindner
- Institute
of Clinical Biochemistry, Innsbruck Medical
University, Innrain 80-82, A-6020 Innsbruck, Austria
| | - Klaus Faserl
- Institute
of Clinical Biochemistry, Innsbruck Medical
University, Innrain 80-82, A-6020 Innsbruck, Austria
| | - Christian Neusüß
- Faculty
of Chemistry, Aalen University, Beethovenstraße 1, 73430 Aalen, Germany
| | - Manuel Nelke
- Faculty
of Chemistry, Aalen University, Beethovenstraße 1, 73430 Aalen, Germany
| | - Stefan Lämmerer
- Faculty
of Chemistry, Aalen University, Beethovenstraße 1, 73430 Aalen, Germany
| | - Catherine Perrin
- Institut
des Biomolécules Max Mousseron (IBMM), UMR 5247-CNRS-UM-ENSCM, Université de Montpellier, 34093 CEDEX 5 Montpellier, France
| | - Claudia Bich-Muracciole
- Institut
des Biomolécules Max Mousseron (IBMM), UMR 5247-CNRS-UM-ENSCM, Université de Montpellier, 34093 CEDEX 5 Montpellier, France
| | - Coral Barbas
- Centre
for Metabolomics and Bioanalysis (CEMBIO), Department of Chemistry
and Biochemistry, Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización
Montepríncipe, Boadilladel
Monte 28660, Madrid, Spain
| | - Ángeles
López Gonzálvez
- Centre
for Metabolomics and Bioanalysis (CEMBIO), Department of Chemistry
and Biochemistry, Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización
Montepríncipe, Boadilladel
Monte 28660, Madrid, Spain
| | - Andras Guttman
- Horváth
Csaba Memorial Laboratory of Bioseparation Sciences, Research Center
for Molecular Medicine, Faculty of Medicine, Doctoral School of Molecular
Medicine, University of Debrecen, 98 Nagyerdei Road, H-4032 Debrecen, Hungary
- Translation
Glycomics Group, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, 10 Egyetem Street, Veszprem H-8200, Hungary
- Sciex, 250 South Kraemer Boulevard, Brea, California 92821, United States
| | - Marton Szigeti
- Horváth
Csaba Memorial Laboratory of Bioseparation Sciences, Research Center
for Molecular Medicine, Faculty of Medicine, Doctoral School of Molecular
Medicine, University of Debrecen, 98 Nagyerdei Road, H-4032 Debrecen, Hungary
- Translation
Glycomics Group, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, 10 Egyetem Street, Veszprem H-8200, Hungary
| | - Philip Britz-McKibbin
- Department
of Chemistry and Chemical Biology, McMaster
University, 1280 Main St. W., Hamilton, Ontario L8S 4M1, Canada
| | - Zachary Kroezen
- Department
of Chemistry and Chemical Biology, McMaster
University, 1280 Main St. W., Hamilton, Ontario L8S 4M1, Canada
| | - Meera Shanmuganathan
- Department
of Chemistry and Chemical Biology, McMaster
University, 1280 Main St. W., Hamilton, Ontario L8S 4M1, Canada
| | - Peter Nemes
- Department
of Chemistry & Biochemistry, University
of Maryland, College
Park, Maryland 20742, United States
| | - Erika P. Portero
- Department
of Chemistry & Biochemistry, University
of Maryland, College
Park, Maryland 20742, United States
| | - Thomas Hankemeier
- Division
of Systems Biomedicine and Pharmacology, Leiden Academic Centre for
Drug Research, Leiden University, 2311 G Leiden, The Netherlands
| | - Santiago Codesido
- School
of Pharmaceutical Sciences, University of
Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Institute
of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
| | - Víctor González-Ruiz
- School
of Pharmaceutical Sciences, University of
Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Institute
of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Swiss Centre for Applied Human Toxicology
(SCAHT), Missionsstrasse
64, 4055 Bâle, Switzerland
| | - Serge Rudaz
- School
of Pharmaceutical Sciences, University of
Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Institute
of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Rue Michel Servet 1, 1211 4 Geneva, Switzerland
- Swiss Centre for Applied Human Toxicology
(SCAHT), Missionsstrasse
64, 4055 Bâle, Switzerland
| | - Rawi Ramautar
- Division
of Systems Biomedicine and Pharmacology, Leiden Academic Centre for
Drug Research, Leiden University, 2311 G Leiden, The Netherlands
| |
Collapse
|
272
|
Larriba-Andaluz C, Prell JS. Fundamentals of ion mobility in the free molecular regime. Interlacing the past, present and future of ion mobility calculations. INT REV PHYS CHEM 2020. [DOI: 10.1080/0144235x.2020.1826708] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Carlos Larriba-Andaluz
- Department of Mechanical Engineering, Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA
| | - James S. Prell
- Department of Chemistry and Biochemistry, University of Oregon, Eugene, OR, USA
| |
Collapse
|
273
|
Zheng H, Zhen XT, Chen Y, Zhu SC, Ye LH, Yang SW, Wang QY, Cao J. In situ antioxidation-assisted matrix solid-phase dispersion microextraction and discrimination of chiral flavonoids from citrus fruit via ion mobility quadrupole time-of-flight high-resolution mass spectrometry. Food Chem 2020; 343:128422. [PMID: 33143965 DOI: 10.1016/j.foodchem.2020.128422] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 10/11/2020] [Accepted: 10/14/2020] [Indexed: 02/07/2023]
Abstract
A simple and sensitive in situ antioxidation process assisted with a matrix solid-phase dispersion method for extracting chiral flavonoids in citrus fruit was established, and samples were further analyzed using ion mobility quadrupole time-of-flight high-resolution mass spectrometry. The collision cross-sections of the target compounds were studied using single-field and stepped-field methods. The optimal conditions were obtained using 30 mg of C18 as a dispersant, methanol as an elution solvent and 0.6 mM 1,1-diphenyl-2-picrylhydrazyl (DPPH) as a radical solution. Additionally, the method showed satisfactory limits of detection (3.70-6.52 ng/mL) and good recoveries (96.78-104.67%) for four flavonoids in citrus fruit. The IC50 values of DPPH radical-scavenging activities ranged from 817.8 to 981.55 μg/mL for tested samples. The method was a good alternative for the microextraction and determination of antioxidant capacity and chiral differentiation of narirutin, naringin, hesperidin and neohesperidin in citrus fruit.
Collapse
Affiliation(s)
- Hui Zheng
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China.
| | - Xiao-Ting Zhen
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China
| | - Yan Chen
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China
| | - Si-Chen Zhu
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China
| | - Li-Hong Ye
- Department of Traditional Chinese Medicine, Hangzhou Red Cross Hospital, Hangzhou 310003, China.
| | - Si-Wei Yang
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China
| | - Qiu-Yan Wang
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China
| | - Jun Cao
- College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou 311121, China.
| |
Collapse
|
274
|
Davis DE, Sherrod SD, Gant-Branum RL, Colby JM, McLean JA. Targeted Strategy to Analyze Antiepileptic Drugs in Human Serum by LC-MS/MS and LC-Ion Mobility-MS. Anal Chem 2020; 92:14648-14656. [PMID: 33047601 PMCID: PMC10103591 DOI: 10.1021/acs.analchem.0c03172] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Routine small-molecule analysis is challenging owing to the need for high selectivity and/or low limits of quantification. This work reports a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify 14 antiepileptic drugs (AEDs) in human serum. For the optimized LC-MS/MS method described herein, we applied the guidelines outlined in the Clinical and Laboratory Standards Institute (CLSI) LC-MS C62-A document and the U.S. Food and Drug Administration (FDA) Bioanalytical Method Validation Guidance for Industry to evaluate the quality of the assay. In these studies, AED linearity, analyte recovery, matrix effects, precision, and accuracy were assessed. Using liquid chromatography-drift tube ion mobility-mass spectrometry (LC-DTIM-MS), a qualitative method was also used to increase confidence in AED identification using accurate mass and collision cross section (CCS) measurements. The LC-DTIM-MS method was also used to assess the ability of drift tube CCS measurements to aid in the separation and identification of AED structural isomers and other AEDs. These data show that another dimension of information, namely CCS measurements, provides an orthogonal dimension of structural information needed for AED analysis. Multiplexed AED measurements using LC-MS/MS and LC-DTIM-MS have the potential to enable better optimization of dosing owing to the high precision capabilities available in these types of analytical studies. Taken together, these data also show the ability to increase confidence in small-molecule identification and quantification using these analytical technologies.
Collapse
Affiliation(s)
- Don E Davis
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Stacy D Sherrod
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Randi L Gant-Branum
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Jennifer M Colby
- Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee 37235, United States
| | - John A McLean
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| |
Collapse
|
275
|
Causon TJ, Hann S. Uncertainty Estimations for Collision Cross Section Determination via Uniform Field Drift Tube-Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2102-2110. [PMID: 32812758 DOI: 10.1021/jasms.0c00233] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Uniform field drift tube ion mobility-mass spectrometry (DTIM-MS) has emerged as a valuable tool for a range of analytical applications. In focus here are standardized collisional cross section values from DTIM-MS (DTCCS) as a candidate identification point for various analytical workflows. Of critical importance in establishing this parameter as a valid identification point is a rugged estimation of uncertainties according to the procedures used for their derivation. Relying on the assumption of the zero-field limit, the primary method of measurement for DTCCS values involves experimental determination of arrival times of an ion measured at several different field strengths transiting a drift tube filled with high purity drift gas, while a method using measurements of external calibrants at a single field strength is employed to allow for online measurements of transient signals (e.g., chromatographic peaks). Both approaches are here considered with respect to the uncertainty of input experimental variables (temperature, pressure, voltages, physical constants) and the steps of the calibration function employed. Estimations of uncertainty were performed according to EURACHEM with Monte Carlo simulations and reveal that existing consensus calibration standards from experimental stepped-field IM-MS determinations have estimated expanded uncertainties in the range of 2.7 to 4.6% (k = 2). Application of these standards for calibration considering these input uncertainties reveals uncertainty estimates of 4.7-9.1% (k = 2) for measured values using an established single-field calibration approach. Finally, directions for improving this situation via new experimental efforts toward standard reference and calibration materials are presented.
Collapse
Affiliation(s)
- Tim J Causon
- Institute of Analytical Chemistry, Department of Chemistry, University of Natural Resources and Life Sciences, Vienna, Muthgasse 18, Vienna 1190, Austria
| | - Stephan Hann
- Institute of Analytical Chemistry, Department of Chemistry, University of Natural Resources and Life Sciences, Vienna, Muthgasse 18, Vienna 1190, Austria
| |
Collapse
|
276
|
Righetti L, Dreolin N, Celma A, McCullagh M, Barknowitz G, Sancho JV, Dall’Asta C. Travelling Wave Ion Mobility-Derived Collision Cross Section for Mycotoxins: Investigating Interlaboratory and Interplatform Reproducibility. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2020; 68:10937-10943. [PMID: 32870673 PMCID: PMC8154562 DOI: 10.1021/acs.jafc.0c04498] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/20/2020] [Accepted: 09/01/2020] [Indexed: 05/24/2023]
Abstract
Parent and modified mycotoxin analysis remains a challenge because of their chemical diversity, the presence of isomeric forms, and the lack of analytical standards. The creation and application of a collision cross section (CCS) database for mycotoxins may bring new opportunities to overcome these analytical challenges. However, it is still an open question whether common CCS databases can be used independently from the instrument type and ion mobility mass spectrometry (IM-MS) technologies, which utilize different methodologies for determining the gas-phase mobility. Here, we demonstrated the reproducibility of CCS measurements for mycotoxins in an interlaboratory study (average RSD 0.14% ± 0.079) and across different traveling wave IM-MS (TWIMS) systems commercially available (ΔCCS% < 2). The separation in the drift time dimension of critical pairs of isomers for modified mycotoxins was also achieved. In addition, the comparison of measured and predicted CCS values, including regulated and emerging mycotoxins, was addressed.
Collapse
Affiliation(s)
- Laura Righetti
- Department
of Food and Drug, University of Parma, Viale Delle Scienze 17/A, I-43124 Parma, Italy
| | - Nicola Dreolin
- Waters
Corporation, Altrincham
Road, SK9 4AX Wilmslow, United Kingdom
| | - Alberto Celma
- Environmental
and Public Health Analytical Chemistry, Research Institute for Pesticides
and Water, University Jaume I, Avda. Sos Baynat s/n, E-12071 Castellón, Spain
| | - Mike McCullagh
- Waters
Corporation, Altrincham
Road, SK9 4AX Wilmslow, United Kingdom
| | - Gitte Barknowitz
- Waters
Corporation, Altrincham
Road, SK9 4AX Wilmslow, United Kingdom
| | - Juan V. Sancho
- Environmental
and Public Health Analytical Chemistry, Research Institute for Pesticides
and Water, University Jaume I, Avda. Sos Baynat s/n, E-12071 Castellón, Spain
| | - Chiara Dall’Asta
- Department
of Food and Drug, University of Parma, Viale Delle Scienze 17/A, I-43124 Parma, Italy
| |
Collapse
|
277
|
Wei J, Tang Y, Ridgeway ME, Park MA, Costello CE, Lin C. Accurate Identification of Isomeric Glycans by Trapped Ion Mobility Spectrometry-Electronic Excitation Dissociation Tandem Mass Spectrometry. Anal Chem 2020; 92:13211-13220. [PMID: 32865981 DOI: 10.1021/acs.analchem.0c02374] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Ion mobility-mass spectrometry (IM-MS) has become a powerful tool for glycan structural characterization due to its ability to separate isomers and provide collision cross section (CCS) values that facilitate structural assignment. However, IM-based isomer analysis may be complicated by the presence of multiple gas-phase conformations of a single structure that not only increases difficulty in isomer separation but can also introduce the possibility for misinterpretation of conformers as isomers. Here, the ion mobility behavior of several sets of isomeric glycans, analyzed as their permethylated derivatives, in both nonreduced and reduced forms, was investigated by gated-trapped ion mobility spectrometry (G-TIMS). Notably, reducing-end reduction, commonly performed to remove anomerism-induced chromatographic peak splitting, did not eliminate the conformational heterogeneity of permethylated glycans in the gas phase. At a mobility resolving power of ∼100, 14 out of 22 structures showed more than one conformation. These results highlight the need to use IMS devices with high mobility resolving power for better separation of isomers and to acquire additional structural information that can differentiate isomers from conformers. Online electronic excitation dissociation (EED) MS/MS analysis of isomeric glycan mixtures following G-TIMS separation showed that EED can generate isomer-specific fragments while producing nearly identical tandem mass spectra for conformers, thus allowing confident identification of isomers with minimal evidence of any ambiguity resulting from the presence of conformers. G-TIMS EED MS/MS analysis of N-linked glycans released from ovalbumin revealed that several mobility features previously thought to arise from isomeric structures were conformers of a single structure. Finally, analysis of ovalbumin N-glycans from different sources showed that the G-TIMS EED MS/MS approach can accurately determine the batch-to-batch variations in glycosylation profiles at the isomer level, with confident assignment of each isomeric structure.
Collapse
Affiliation(s)
- Juan Wei
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, 670 Albany Street, Room 508, Boston, Massachusetts 02118, United States
| | - Yang Tang
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, 670 Albany Street, Room 508, Boston, Massachusetts 02118, United States.,Department of Chemistry, Boston University, Boston, Massachusetts 02215, United States
| | - Mark E Ridgeway
- Bruker Daltonics, Billerica, Massachusetts 01821, United States
| | - Melvin A Park
- Bruker Daltonics, Billerica, Massachusetts 01821, United States
| | - Catherine E Costello
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, 670 Albany Street, Room 508, Boston, Massachusetts 02118, United States.,Department of Chemistry, Boston University, Boston, Massachusetts 02215, United States
| | - Cheng Lin
- Center for Biomedical Mass Spectrometry, Boston University School of Medicine, 670 Albany Street, Room 508, Boston, Massachusetts 02118, United States
| |
Collapse
|
278
|
Drouin N, Mielcarek A, Wenz C, Rudaz S. Evaluation of ion mobility in capillary electrophoresis coupled to mass spectrometry for the identification in metabolomics. Electrophoresis 2020; 42:342-349. [PMID: 32744343 DOI: 10.1002/elps.202000120] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 07/16/2020] [Accepted: 07/20/2020] [Indexed: 01/21/2023]
Abstract
Currently, feature annotation remains one of the main challenges in untargeted metabolomics. In this context, the information provided by high-resolution mass spectrometry (HRMS) in addition to accurate mass can improve the quality of metabolite annotation, and MS/MS fragmentation patterns are widely used. Accurate mass and a separation index, such as retention time or effective mobility (μeff ), in chromatographic and electrophoretic approaches, respectively, must be used for unequivocal metabolite identification. The possibility of measuring collision cross-section (CCS) values by using ion mobility (IM) is becoming increasingly popular in metabolomic studies thanks to the new generation of IM mass spectrometers. Based on their similar separation mechanisms involving electric field and the size of the compounds, the complementarity of DT CCSN2 and μeff needs to be evaluated. In this study, a comparison of DT CCSN2 and μeff was achieved in the context of feature identification ability in untargeted metabolomics by capillary zone electrophoresis (CZE) coupled with HRMS. This study confirms the high correlation of DT CCSN2 with the mass of the studied metabolites as well as the orthogonality between accurate mass and μeff , making this combination particularly interesting for the identification of several endogenous metabolites. The use of IM-MS remains of great interest for facilitating the annotation of neutral metabolites present in the electroosmotic flow (EOF) that are poorly or not separated by CZE.
Collapse
Affiliation(s)
- Nicolas Drouin
- Division of Systems Biomedicine and Pharmacology, Leiden Academic Center for Drug Research, Leiden University, The Netherlands.,Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Geneva, Switzerland
| | | | - Christian Wenz
- Agilent Technologies, Hewlett-Packard, Waldbronn, Germany
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Geneva, Switzerland
| |
Collapse
|
279
|
Kwantwi-Barima P, Hogan CJ, Clowers BH. Probing Gas-Phase-Clustering Thermodynamics with Ion Mobility-Mass Spectrometry: Association Energies of Phenylalanine Ions with Gas-Phase Alcohols. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1803-1814. [PMID: 32687705 DOI: 10.1021/jasms.0c00020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Vapor assisted mobility shift measurements were made with atmospheric pressure drift-tube ion mobility-mass spectrometry (IM-MS) to determine the thermodynamic properties of weakly bound ion-molecule clusters formed from protonated phenylalanine and neutral vapor molecules with hydroxyl functional groups. Relative binding energies and gas-phase association energies of amino acid ions clustered with small organic molecules have been established previously using high-pressure mass spectrometry. However, the issue of volatility largely prohibits the use of high-pressure mass spectrometry for the determination of gas-phase associations of amino acid ions clustered with neutral vapor molecules in many instances. In contrast, ion mobility measurements can be made at atmospheric pressure with volatile vapor additives near and above their boiling points, providing access to clustering equilibria not possible using high-vacuum techniques. In this study, we report the gas-phase association energies, enthalpies, and entropies for a protonated phenylalanine ion clustered with three neutral vapor molecules: 2-propanol, 1-butanol, and 2-pentanol based upon measurements at temperatures ranging from 120 to 180 °C. The gas-phase enthalpy and entropy changes ranged between -4 to -7 kcal/mol and -3 to 6 cal/(mol K), respectively. We found enthalpically favored ion-neutral cluster reactions for phenylalanine with entropic barriers for the formation of phenylalanine-1-butanol and phenylalanine-2-pentanol cluster ions, while phenylalanine-2-propanol cluster ion formation is both enthalpically and (weakly) entropically favorable. Under the measurement conditions examined, phenylalanine-vapor modifier cluster ion formation is clearly observed via shifts in the drift time for the three test vapor molecules. In comparison, negligible shifts in mobility are observed for protonated arginine exposed to the same vapor modifiers.
Collapse
Affiliation(s)
- Pearl Kwantwi-Barima
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| | - Christopher J Hogan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
280
|
Gerner C, Costigliola V, Golubnitschaja O. MULTIOMIC PATTERNS IN BODY FLUIDS: TECHNOLOGICAL CHALLENGE WITH A GREAT POTENTIAL TO IMPLEMENT THE ADVANCED PARADIGM OF 3P MEDICINE. MASS SPECTROMETRY REVIEWS 2020; 39:442-451. [PMID: 31737933 DOI: 10.1002/mas.21612] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Accepted: 10/15/2019] [Indexed: 06/10/2023]
Abstract
Liquid biopsy (LB) is defined as a sample of any of body fluids (blood, saliva, tear fluid, urine, sweat, amniotic, cerebrospinal and pleural fluids, cervicovaginal secretion, and wound efflux, amongst others), which can be ex vivo analysed to detect and quantity the target(s) of interest. LB represents diagnostic approach relevant for organ-specific changes and systemic health conditions including both manifested diseases and their prestages such as suboptimal health. Further, experts emphasise that DNA-based analysis alone does not provide sufficient information for optimal diagnostics and effective treatments. Consequently, of great scientific and clinical utility are molecular patterns detected by hybrid technologies such as metabolomic tools and molecular imaging. Future proposed strategies utilise multiomic pillars (generally genome, tanscriptome, proteome, metabolome, epigenome, radiome, and microbiome), system-biological approach, and multivariable algorithms for diagnostic, prognostic, and therapeutic purposes. Current article analyses pros and cons of the mass spectrometry-based technologies, provides eminent examples of a success story "from discovery to clinical application," and demonstrates a "road-map" for the technology-driven paradigm change from reactive to predictive, preventive and personalised medical services as the medicine of the future benefiting the patient and healthcare at large. © 2019 The Authors. Mass Spectrometry Reviews published by John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Christopher Gerner
- Department of Analytical Chemistry, Faculty of Chemistry and Joint Metabolome Facility, University of Vienna, Vienna, Austria
- European Association for Predictive, Preventive and Personalised Medicine (EPMA), Brussels, Belgium
| | - Vincenzo Costigliola
- European Association for Predictive, Preventive and Personalised Medicine (EPMA), Brussels, Belgium
- European Medical Association (EMA), Brussels, Belgium
| | - Olga Golubnitschaja
- European Association for Predictive, Preventive and Personalised Medicine (EPMA), Brussels, Belgium
- Radiological Clinic, UKB, Excellence Friedrich-Wilhelms-University Bonn, Bonn, Germany
- Breast Cancer Research Centre, UKB, Excellence Friedrich-Wilhelms-University Bonn, Bonn, Germany
- Centre for Integrated Oncology, Cologne-Bonn, Excellence Friedrich-Wilhelms-University Bonn, Bonn, Germany
| |
Collapse
|
281
|
Leyva D, Jaffe R, Fernandez-Lima F. Structural Characterization of Dissolved Organic Matter at the Chemical Formula Level Using TIMS-FT-ICR MS/MS. Anal Chem 2020; 92:11960-11966. [PMID: 32786462 DOI: 10.1021/acs.analchem.0c02347] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
TIMS-FT-ICR MS is an important alternative to study the isomeric diversity and elemental composition of complex mixtures. While the chemical structure of many compounds in the dissolved organic matter (DOM) remains largely unknown, the high structural diversity has been described at the molecular level using chemical formulas. In this study, we further push the boundaries of TIMS-FT-ICR MS by performing chemical formula-based ion mobility and tandem MS analysis for the structural characterization of DOM. The workflow described is capable to mobility select (R ∼ 100) and isolate molecular ion signals (Δm/z = 0.036) in the ICR cell, using single-shot ejections after broadband ejections and MS/MS based on sustained off-resonance irradiation collision-induced dissociation (SORI-CID). The workflow results are compared to alternative TIMS-q-FT-ICR MS/MS experiments with quadrupole isolation at nominal mass (∼1 Da). The technology is demonstrated with isomeric and isobaric mixtures (e.g., 4-methoxy-1-naphthoic acid, 2-methoxy-1-naphthoic acid, decanedioic acid) and applied to the characterization of DOM. The application of this new methodology to the analysis of a DOM is illustrated by the isolation of the molecular ion [C18H18O10-H]- in the presence of other isobars at nominal mass 393. Five IMS bands were assigned to the heterogeneous ion mobility profile of [C18H18O10-H]-, and candidate structures from the PubChem database were screened based on their ion mobility and the MS/MS matching score. This approach overcomes traditional challenges associated with the similarity of fragmentation patterns of DOM samples (e.g., common neutral losses of H2O, CO2, and CH2-H2O) by narrowing down the isomeric candidate structures using the mobility domain.
Collapse
|
282
|
McCabe JW, Mallis CS, Kocurek KI, Poltash ML, Shirzadeh M, Hebert MJ, Fan L, Walker TE, Zheng X, Jiang T, Dong S, Lin CW, Laganowsky A, Russell DH. First-Principles Collision Cross Section Measurements of Large Proteins and Protein Complexes. Anal Chem 2020; 92:11155-11163. [PMID: 32662991 PMCID: PMC7967297 DOI: 10.1021/acs.analchem.0c01285] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Rotationally averaged collision cross section (CCS) values for a series of proteins and protein complexes ranging in size from 8.6 to 810 kDa are reported. The CCSs were obtained using a native electrospray ionization drift tube ion mobility-Orbitrap mass spectrometer specifically designed to enhance sensitivity while having high-resolution ion mobility and mass capabilities. Periodic focusing (PF)-drift tube (DT)-ion mobility (IM) provides first-principles determination of the CCS of large biomolecules that can then be used as CCS calibrants. The experimental, first-principles CCS values are compared to previously reported experimentally determined and computationally calculated CCS using projected superposition approximation (PSA), the Ion Mobility Projection Approximation Calculation Tool (IMPACT), and Collidoscope. Experimental CCS values are generally in agreement with previously reported CCSs, with values falling within ∼5.5%. In addition, an ion mobility resolution (CCS centroid divided by CCS fwhm) of ∼60 is obtained for pyruvate kinase (MW ∼ 233 kDa); however, ion mobility resolution for bovine serum albumin (MW ∼ 68 kDa) is less than ∼20, which arises from sample impurities and underscores the importance of sample quality. The high resolution afforded by the ion mobility-Orbitrap mass analyzer provides new opportunities to understand the intricate details of protein complexes such as the impact of post-translational modifications (PTMs), stoichiometry, and conformational changes induced by ligand binding.
Collapse
Affiliation(s)
- Jacob W McCabe
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Christopher S Mallis
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Klaudia I Kocurek
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Michael L Poltash
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Mehdi Shirzadeh
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Michael J Hebert
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Liqi Fan
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Thomas E Walker
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Xueyun Zheng
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Ting Jiang
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Shiyu Dong
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Cheng-Wei Lin
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - Arthur Laganowsky
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| | - David H Russell
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
283
|
Harris RA, Picache JA, Tomlinson ID, Zlibut E, Ellis BM, May JC, McLean JA, Hercules DM. Mass spectrometry and ion mobility study of poly(ethylene glycol)-based polyurethane oligomers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8662. [PMID: 31731326 DOI: 10.1002/rcm.8662] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Revised: 11/07/2019] [Accepted: 11/13/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Commercial-grade polymer synthesis is performed via melt polymerization, which leads to polydispersion. The work reported herein provides a synthetic strategy to produce mono-dispersive polyurethane oligomers and an analytical strategy to distinguish these oligomers, providing chemists with the tools necessary to synthesize and identify specific polymer structures that exhibit a desired property. METHODS Three isomeric poly(ethylene glycol)-polyurethane (PEG-PUR) oligomers were synthesized and analyzed via flow-injection ion mobility mass spectrometry (IM-MS). Each polymer oligomer was injected and run independently via flow injection at 100 μL•min-1 and analyzed in positive ion mode on a drift tube quadrupole time-of-flight (QTOF) instrument. Mobility measurements were determined using a single-field approach. For tandem mass spectrometry (MS/MS) experiments, the sodium-adducted singly charged precursor ion was isolated in the quadrupole and subjected to a range of collision energies. RESULTS In MS experiments, both +1 and +2 sodium-adducted species were observed for each oligomer at m/z 837.4 and 430.2, respectively. When isolated and fragmented via MS/MS, the +1 precursor yielded distinct product ions for each of the three isomeric oligomers. Fragmentation generally occurred at urethane linkages via 1,3- and 1,5-H shift mechanisms. IM was also used to distinguish the three isomers, with greater IM separation observed for the +2 versus the +1 species. CONCLUSIONS Mono-disperse PEG-PUR oligomers were synthesized and analyzed. Although the polymeric oligomers analyzed in this study are quite small and structurally simple, this work serves as a model system for the synthesis and structural characterization of larger, more complex block copolymers.
Collapse
Affiliation(s)
- Rachel A Harris
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, 37235, USA
| | - Jaqueline A Picache
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, 37235, USA
| | - Ian D Tomlinson
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Vanderbilt Institute of Nanoscale Science and Engineering, Vanderbilt University, Nashville, TN, 37235, USA
| | - Emanuel Zlibut
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, 37235, USA
| | - Berkley M Ellis
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, 37235, USA
| | - Jody C May
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, 37235, USA
| | - John A McLean
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
- Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, 37235, USA
| | - David M Hercules
- Department of Chemistry, Vanderbilt University, Nashville, TN, 37235, USA
| |
Collapse
|
284
|
Mullin L, Jobst K, DiLorenzo RA, Plumb R, Reiner EJ, Yeung LW, Jogsten IE. Liquid chromatography-ion mobility-high resolution mass spectrometry for analysis of pollutants in indoor dust: Identification and predictive capabilities. Anal Chim Acta 2020; 1125:29-40. [DOI: 10.1016/j.aca.2020.05.052] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 05/16/2020] [Accepted: 05/21/2020] [Indexed: 01/01/2023]
|
285
|
Couvillion SP, Agrawal N, Colby SM, Brandvold KR, Metz TO. Who Is Metabolizing What? Discovering Novel Biomolecules in the Microbiome and the Organisms Who Make Them. Front Cell Infect Microbiol 2020; 10:388. [PMID: 32850487 PMCID: PMC7410922 DOI: 10.3389/fcimb.2020.00388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Accepted: 06/25/2020] [Indexed: 12/14/2022] Open
Abstract
Even as the field of microbiome research has made huge strides in mapping microbial community composition in a variety of environments and organisms, explaining the phenotypic influences on the host by microbial taxa-both known and unknown-and their specific functions still remain major challenges. A pressing need is the ability to assign specific functions in terms of enzymes and small molecules to specific taxa or groups of taxa in the community. This knowledge will be crucial for advancing personalized therapies based on the targeted modulation of microbes or metabolites that have predictable outcomes to benefit the human host. This perspective article advocates for the combined use of standards-free metabolomics and activity-based protein profiling strategies to address this gap in functional knowledge in microbiome research via the identification of novel biomolecules and the attribution of their production to specific microbial taxa.
Collapse
Affiliation(s)
- Sneha P. Couvillion
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States
| | - Neha Agrawal
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States
| | - Sean M. Colby
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States
| | - Kristoffer R. Brandvold
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States
- Elson S. Floyd College of Medicine, Washington State University, Spokane, WA, United States
| | - Thomas O. Metz
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States
| |
Collapse
|
286
|
Picache JA, May JC, McLean JA. Chemical Class Prediction of Unknown Biomolecules Using Ion Mobility-Mass Spectrometry and Machine Learning: Supervised Inference of Feature Taxonomy from Ensemble Randomization. Anal Chem 2020; 92:10759-10767. [DOI: 10.1021/acs.analchem.0c02137] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Jaqueline A. Picache
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Jody C. May
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - John A. McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| |
Collapse
|
287
|
May JC, Knochenmuss R, Fjeldsted JC, McLean JA. Resolution of Isomeric Mixtures in Ion Mobility Using a Combined Demultiplexing and Peak Deconvolution Technique. Anal Chem 2020; 92:9482-9492. [DOI: 10.1021/acs.analchem.9b05718] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Jody C. May
- Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37235, United States
| | | | | | - John A. McLean
- Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37235, United States
| |
Collapse
|
288
|
Naylor CN, Ridgeway ME, Park MA, Clowers BH. Evaluation of Trapped Ion Mobility Spectrometry Source Conditions Using Benzylammonium Thermometer Ions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1593-1602. [PMID: 32510214 DOI: 10.1021/jasms.0c00151] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A key aspect of reduced pressure ion mobility spectrometry (IMS) experiments is to identify experimental conditions that minimize the role of collisional energy transfer that allows for assessing effective ion-neutral collision cross sections of metabolites, peptides, and proteins in "native-like" or compact states. Across two separate experimental campaigns using a prototype trapped ion mobility spectrometer (TIMS) coupled to a time-of-flight mass spectrometer, we present independent findings that support the results recently published by Morsa et al. using a different set of thermometer ions (Morsa et al. Anal. Chem. 2020, 92 (6), 4573-4582). First, using five para-substituted benzylammonium ions, we conducted survival yield experiments to assess ion internal energy across different experimental settings. Results from the present set of experiments illustrate that greater ion heating occurs at lower pressures and higher voltage settings applied to the TIMS. At the "softest" settings where the benzylammonium thermometer ions have an effective average energy of 1.73 eV, we observe the majority of bradykinin in the compact state. Under more extreme operating conditions where the energy of the benzylammonium ions varies from 1.83 to 1.86 eV, the bradykinin transitions from the compact to the elongated state. In addition to independently confirming the findings of Morsa et al., we also report the mobilities for the benzylammonium parent and fragment ions using the tandem drift-tube-TIMS calibration procedure described by Naylor et al. ( J. Am. Soc. Mass Spectrom. 2019, 30 (10), 2152-2162).
Collapse
Affiliation(s)
- Cameron N Naylor
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - Mark E Ridgeway
- Bruker Daltonics Inc., Billerica, Massachusetts 01821, United States
| | - Melvin A Park
- Bruker Daltonics Inc., Billerica, Massachusetts 01821, United States
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| |
Collapse
|
289
|
Radchenko T, Kochansky CJ, Cancilla M, Wrona MD, Mortishire-Smith RJ, Kirk J, Murray G, Fontaine F, Zamora I. Metabolite identification using an ion mobility enhanced data-independent acquisition strategy and automated data processing. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8792. [PMID: 32208529 DOI: 10.1002/rcm.8792] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Revised: 03/20/2020] [Accepted: 03/21/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE Liquid chromatography/mass spectrometry is an essential tool for efficient and reliable quantitative and qualitative analysis and underpins much of contemporary drug metabolism and pharmacokinetics. Data-independent acquisition methods such as MSE have reduced the potential to miss metabolites, but do not formally generate quadrupole-resolved product ion spectra. The addition of ion mobility separation to these approaches, for example, in High-Definition MSE (HDMSE ) has the potential to reduce the time needed to set up an experiment and maximize the chance that all metabolites present can be resolved and characterized. We compared High-Definition Data-Dependent Acquisition (HD-DDA), MSE and HDMSE approaches using automated software processing with Mass-MetaSite and WebMetabase. METHODS Metabolite identification was performed on incubations of glucagon-like peptide-1 (7-37) (GLP-1) and verapamil hydrochloride. The HD-DDA, MSE and HDMSE experiments were conducted on a Waters ACQUITY UPLC I-Class LC system with a VION IMS quadrupole time-of-flight (QTOF) mass spectrometer operating under UNIFI control. All acquired data were processed using MassMetaSite able to read data from UNIFI 1.9.4. WebMetabase was used to review the detected chromatographic peaks and the spectral data interpretations. RESULTS A comparison of outcomes obtained for MSE and HDMSE data demonstrated that the same structures were proposed for metabolites of both verapamil and GLP-1. The ratio of structurally matched to mismatched product ions found by MassMetaSite was slightly greater for HDMSE than for MSE , and HD-DDA, thus improving confidence in the structures proposed through the addition of ion mobility based data acquisitions. CONCLUSIONS: HDMSE data acquisition is an effective approach for the elucidation of metabolite structures for both small molecules and peptides, with excellent accuracy and quality, requiring minimal tailoring for the compound under investigation.
Collapse
Affiliation(s)
- Tatiana Radchenko
- Lead Molecular Design, S.L., Sant Cugat Del Valles, Spain
- Universitat Pompeu Fabra, Pl. de la Merce, 10-12, Barcelona, Spain
| | | | | | | | | | | | | | | | - Ismael Zamora
- Lead Molecular Design, S.L., Sant Cugat Del Valles, Spain
- Molecular Discovery Ltd, London, UK
| |
Collapse
|
290
|
Poland JC, Leaptrot KL, Sherrod SD, Flynn CR, McLean JA. Collision Cross Section Conformational Analyses of Bile Acids via Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:10.1021/jasms.0c00015. [PMID: 32525305 PMCID: PMC8059067 DOI: 10.1021/jasms.0c00015] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Bile acids serve as one of the most important classes of biological molecules in the gastrointestinal system. Due to their structural similarity, bile acids have historically been difficult to accurately annotate in complex biological matrices using mass spectrometry. They often have identical or nominally similar mass-to-charge ratios and similar fragmentation patterns that make identification by mass spectrometry arduous, normally involving chemical derivatization and separation via liquid chromatography. Here, we demonstrate the use of drift tube ion mobility (DTIM) to derive collision cross section (CCS) values in nitrogen drift gas (DTCCSN2) for use as an additional descriptor to facilitate expedited bile acid identification. We also explore trends in DTIM measurements and detail structural characteristics for differences in DTCCSN2 values between subclasses of bile acid molecules.
Collapse
Affiliation(s)
- James C Poland
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Katrina L Leaptrot
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Stacy D Sherrod
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Charles Robb Flynn
- Department of Surgery, Vanderbilt University Medical Center, Nashville, Tennessee 37235, United States
| | - John A McLean
- Center for Innovative Technology, Department of Chemistry, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| |
Collapse
|
291
|
Soper-Hopper MT, Vandegrift J, Baker ES, Fernández FM. Metabolite collision cross section prediction without energy-minimized structures. Analyst 2020; 145:5414-5418. [PMID: 32583823 DOI: 10.1039/d0an00198h] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Matching experimental ion mobility-mass spectrometry data to computationally-generated collision cross section (CCS) values enables more confident metabolite identifications. Here, we show for the first time that accurately predicting CCS values with simple models for the largest library of metabolite cross sections is indeed possible, achieving a root mean square error of 7.0 Å2 (median error of ∼2%) using linear methods accesible to most researchers. A comparison on the performance of 2D vs. 3D molecular descriptors for the purposes of CCS prediction is also presented for the first time, enabling CCS prediction without a priori knowledge of the metabolite's energy-minimized structure.
Collapse
Affiliation(s)
- M T Soper-Hopper
- Northern Kentucky University, Department of Chemistry and Biochemistry, 1 Nunn Drive, Highland Heights, KY 41099, USA
| | | | | | | |
Collapse
|
292
|
Chatterjee P, Dutta SS, Chakraborty T. Isomers and Rotamers of DCM in Methanol and in Gas Phase Probed by Ion Mobility Mass Spectrometry in Combination with High Performance Liquid Chromatography. J Phys Chem B 2020; 124:4498-4511. [PMID: 32380830 DOI: 10.1021/acs.jpcb.0c00097] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
An integrated method of ion mobility mass spectrometry and high-performance liquid chromatography (HPLC) has been used to investigate the isomeric distribution of a popular fluorescent dye DCM (4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran) in methanol solution. Chromatographic separation of DCM isomers in methanol has been performed by probing the molecular mass (DCMH+), and two distinctly separated peaks are observed at retention times 3.73 (peak-I) and 3.87 (peak-II) min, where the latter one appears nearly twice as intense as the former. However, peak-I appears much weaker compared to peak-II if the chromatogram is recorded by optical probing at the absorption maximum of this dye (467 nm). The ion mobility (IM) spectra of DCMH+ ions corresponding to each of the LC-separated factions show three common peaks A, B, and C, with collision cross-section (CCS) values of 174, 185, and 197 Å2, respectively, but their relative intensities in the two IM spectra appear in opposite sequences. The three IM peaks have been assigned by considering the theoretically calculated CCS values of 13 possible isomers of DCMH+ ions. The IM spectral features also reveal that isomeric interconversions occur during the ESI process. Electronic structure calculations have been used to optimize the geometries of the four isomers of solvated DCM and the corresponding protomeric structures of DCMH+. The isomerization pathways and associated energy barriers have also been calculated. The gas-phase protomers are found to follow a completely different sequence of stability as compared to the neutral isomers. The analysis reveals that peak-I corresponds to one of the cis isomers, whereas peak-II arises due to cumulative contributions of the other three isomers. The absorption spectrum of DCM in methanol is simulated from the computed spectral profiles of the isomers which indicates a distribution of trans1, trans2, cis1, and cis2 isomers as 33.5, 61.5, 2.0, and 3.0%, respectively. The fragmentation behavior of DCMH+ ions in a collision-induced dissociation experiment has been found to be isomer dependent.
Collapse
Affiliation(s)
- Piyali Chatterjee
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A Raja S C Mullick Road, Jadavpur, Kolkata 700032, India
| | - Subhra Sankar Dutta
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A Raja S C Mullick Road, Jadavpur, Kolkata 700032, India
| | - Tapas Chakraborty
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A Raja S C Mullick Road, Jadavpur, Kolkata 700032, India
| |
Collapse
|
293
|
Nys G, Nix C, Cobraiville G, Servais AC, Fillet M. Enhancing protein discoverability by data independent acquisition assisted by ion mobility mass spectrometry. Talanta 2020; 213:120812. [DOI: 10.1016/j.talanta.2020.120812] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 02/01/2020] [Accepted: 02/07/2020] [Indexed: 11/28/2022]
|
294
|
Luo MD, Zhou ZW, Zhu ZJ. The Application of Ion Mobility-Mass Spectrometry in Untargeted Metabolomics: from Separation to Identification. JOURNAL OF ANALYSIS AND TESTING 2020. [DOI: 10.1007/s41664-020-00133-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
295
|
Hollerbach AL, Li A, Prabhakaran A, Nagy G, Harrilal CP, Conant CR, Norheim RV, Schimelfenig CE, Anderson GA, Garimella SVB, Smith RD, Ibrahim YM. Ultra-High-Resolution Ion Mobility Separations Over Extended Path Lengths and Mobility Ranges Achieved using a Multilevel Structures for Lossless Ion Manipulations Module. Anal Chem 2020; 92:7972-7979. [PMID: 32383592 DOI: 10.1021/acs.analchem.0c01397] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Over the past few years, structures for lossless ion manipulations (SLIM) have used traveling waves (TWs) to move ions over long serpentine paths that can be further lengthened by routing the ions through multiple passages of the same path. Such SLIM "multipass" separations provide unprecedentedly high ion mobility resolving powers but are ultimately limited in their ion mobility range because of the range of mobilities spanned in a single pass; that is, higher mobility ions ultimately "overtake" and "lap" lower mobility ions that have experienced fewer passes, convoluting their arrival time distribution at the detector. To achieve ultrahigh resolution separations over broader mobility ranges, we have developed a new multilevel SLIM possessing multiple stacked serpentine paths. Ions are transferred between SLIM levels through apertures (or ion escalators) in the SLIM surfaces. The initial multilevel SLIM module incorporates four levels and three interlevel ion escalator passages, providing a total path length of 43.2 m. Using the full path length and helium buffer gas, high resolution separations were achieved for Agilent tuning mixture phosphazene ions over a broad mobility range (K0 ≈ 3.0 to 1.2 cm2/(V*s)). High sensitivity was achieved using "in-SLIM" ion accumulation over an extended trapping region of the first SLIM level. High transmission efficiency of ions over a broad mobility range (e.g., K0 ≈ 3.0 to 1.67 cm2/(V*s)) was achieved, with transmission efficiency rolling off for the lower mobility ions (e.g., K0 ≈ 1.2 cm2/(V*s)). Resolving powers of up to ∼560 were achieved using all four ion levels to separate reverse peptides (SDGRG1+ and GRGDS1+). A complex mixture of phosphopeptides showed similar coverage could be achieved using one or all four SLIM levels, and doubly charged phosphosite isomers not significantly separated using one SLIM level were well resolved when four levels were used. The new multilevel SLIM technology thus enables wider mobility range ultrahigh-resolution ion mobility separations and expands on the ability of SLIM to obtain improved separations of complex mixtures with high sensitivity.
Collapse
Affiliation(s)
- Adam L Hollerbach
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Ailin Li
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Aneesh Prabhakaran
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Gabe Nagy
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Christopher P Harrilal
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Christopher R Conant
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Randolph V Norheim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Colby E Schimelfenig
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Gordon A Anderson
- GAA Custom Engineering, LLC, P.O. Box 335, Benton City, Washington 99320, United States
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99354, United States
| |
Collapse
|
296
|
Wang K, Qiu R, Zhang X, Gillig KJ, Sun W. U-Shaped Mobility Analyzer: A Compact and High-Resolution Counter-Flow Ion Mobility Spectrometer. Anal Chem 2020; 92:8356-8363. [DOI: 10.1021/acs.analchem.0c00868] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Keke Wang
- Shimadzu Research Laboratory (Shanghai) Co. Ltd., Shanghai 201206, People’s Republic of China
| | - Ran Qiu
- Shimadzu Research Laboratory (Shanghai) Co. Ltd., Shanghai 201206, People’s Republic of China
| | - Xiaoqiang Zhang
- Shimadzu Research Laboratory (Shanghai) Co. Ltd., Shanghai 201206, People’s Republic of China
| | - Kent J. Gillig
- Genomics Research Center, Academia Sinica, Taipei 115, Taiwan
| | - Wenjian Sun
- Shimadzu Research Laboratory (Shanghai) Co. Ltd., Shanghai 201206, People’s Republic of China
| |
Collapse
|
297
|
Xie C, Wu Q, Zhang S, Wang C, Gao W, Yu J, Tang K. Improving glycan isomeric separation via metal ion incorporation for drift tube ion mobility-mass spectrometry. Talanta 2020; 211:120719. [DOI: 10.1016/j.talanta.2020.120719] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 12/29/2019] [Accepted: 01/03/2020] [Indexed: 11/30/2022]
|
298
|
Calabrese V, Lavanant H, Rosu F, Gabelica V, Afonso C. Collision Cross Sections of Phosphoric Acid Cluster Anions in Helium Measured by Drift Tube Ion Mobility Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:969-981. [PMID: 32153193 DOI: 10.1021/jasms.0c00034] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In the last years, ion mobility mass spectrometry (IMS-MS) has improved structural analysis and compound identification by giving access to the collision cross section (CCS). An increasingly wide and accurate database of CCS values is now available but often without assessment of the influence of different instrumental settings on CCS values. Here, we present 75 CCS values in helium (DTCCSHe) for phosphoric acid cluster anions [(H3PO4)n - zH]z- with charge state (z) up to 4-. The CCS values, noted DTCCSHe, were obtained with a commercial drift tube ion mobility mass spectrometer, in helium, by applying a classic multifield approach. Phosphoric acid clusters are fragile structures that allow to evaluate the effect of different experimental conditions on the retention of weak bonds and their effect on CCS values. We probed harsh and soft voltage gradients in the electrospray (ESI) source before the IMS and two different voltage gradients in the post-IMS region. The variations in the ion mobility and mass spectra consisted in a change in the distribution of the cluster anions aggregation numbers (n) and charge states (z), with a higher amount of multiply charged species for the soft pre-IMS voltage gradient and a lower proportion of cluster dissociation for soft post-IMS conditions. However, the CCS values did not change with experimental conditions for a given cluster, as long as it stays intact from the IMS to the mass analyzer. The DTCCSHe were found in good agreement among 3 to 10 replicated values, with a relative standard deviation between 0.1 and 1.7%.
Collapse
Affiliation(s)
- Valentina Calabrese
- Normandie University, UNIROUEN, INSA Rouen, CNRS, COBRA, 76000 Rouen, France
| | - Hélène Lavanant
- Normandie University, UNIROUEN, INSA Rouen, CNRS, COBRA, 76000 Rouen, France
| | - Frédéric Rosu
- CNRS, University of Bordeaux and INSERM, Institut Européen de Chimie et Biologie (IECB, UMS3033, US001), 2 Rue Robert Escarpit, 33600 Pessac, France
| | - Valérie Gabelica
- University of Bordeaux, INSERM and CNRS, Laboratoire Acides Nucléiques: Régulations Naturelle et Artificielle (ARNA, U1212, UMR5320), Site IECB, 2 Rue Robert Escarpit, 33600 Pessac, France
| | - Carlos Afonso
- Normandie University, UNIROUEN, INSA Rouen, CNRS, COBRA, 76000 Rouen, France
| |
Collapse
|
299
|
Graton J, Hernández-Mesa M, Normand S, Dervilly G, Le Questel JY, Le Bizec B. Characterization of Steroids through Collision Cross Sections: Contribution of Quantum Chemistry Calculations. Anal Chem 2020; 92:6034-6042. [DOI: 10.1021/acs.analchem.0c00357] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Jérôme Graton
- CNRS, CEISAM, UMR 6230, Université de Nantes, Nantes F-44000, France
| | - Maykel Hernández-Mesa
- Laboratoire d’Etude des Résidus et Contaminants dans les Aliments (LABERCA), INRAE, Oniris, Nantes F-44307, France
| | - Samuel Normand
- CNRS, CEISAM, UMR 6230, Université de Nantes, Nantes F-44000, France
| | - Gaud Dervilly
- Laboratoire d’Etude des Résidus et Contaminants dans les Aliments (LABERCA), INRAE, Oniris, Nantes F-44307, France
| | | | - Bruno Le Bizec
- Laboratoire d’Etude des Résidus et Contaminants dans les Aliments (LABERCA), INRAE, Oniris, Nantes F-44307, France
| |
Collapse
|
300
|
Hernández-Mesa M, D'Atri V, Barknowitz G, Fanuel M, Pezzatti J, Dreolin N, Ropartz D, Monteau F, Vigneau E, Rudaz S, Stead S, Rogniaux H, Guillarme D, Dervilly G, Le Bizec B. Interlaboratory and Interplatform Study of Steroids Collision Cross Section by Traveling Wave Ion Mobility Spectrometry. Anal Chem 2020; 92:5013-5022. [PMID: 32167758 DOI: 10.1021/acs.analchem.9b05247] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Collision cross section (CCS) databases based on single-laboratory measurements must be cross-validated to extend their use in peak annotation. This work addresses the validation of the first comprehensive TWCCSN2 database for steroids. First, its long-term robustness was evaluated (i.e., a year and a half after database generation; Synapt G2-S instrument; bias within ±1.0% for 157 ions, 95.7% of the total ions). It was further cross-validated by three external laboratories, including two different TWIMS platforms (i.e., Synapt G2-Si and two Vion IMS QToF; bias within the threshold of ±2.0% for 98.8, 79.9, and 94.0% of the total ions detected by each instrument, respectively). Finally, a cross-laboratory TWCCSN2 database was built for 87 steroids (142 ions). The cross-laboratory database consists of average TWCCSN2 values obtained by the four TWIMS instruments in triplicate measurements. In general, lower deviations were observed between TWCCSN2 measurements and reference values when the cross-laboratory database was applied as a reference instead of the single-laboratory database. Relative standard deviations below 1.5% were observed for interlaboratory measurements (<1.0% for 85.2% of ions) and bias between average values and TWCCSN2 measurements was within the range of ±1.5% for 96.8% of all cases. In the context of this interlaboratory study, this threshold was also suitable for TWCCSN2 measurements of steroid metabolites in calf urine. Greater deviations were observed for steroid sulfates in complex urine samples of adult bovines, showing a slight matrix effect. The implementation of a scoring system for the application of the CCS descriptor in peak annotation is also discussed.
Collapse
Affiliation(s)
| | - Valentina D'Atri
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Gitte Barknowitz
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, U.K
| | - Mathieu Fanuel
- INRAE, UR1268 Biopolymers Interactions Assemblies (BIA), Rue de la Géraudière B.P. 71627, F-44316 Nantes, France
| | - Julian Pezzatti
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Nicola Dreolin
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, U.K
| | - David Ropartz
- INRAE, UR1268 Biopolymers Interactions Assemblies (BIA), Rue de la Géraudière B.P. 71627, F-44316 Nantes, France
| | | | | | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Sara Stead
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, U.K
| | - Hélène Rogniaux
- INRAE, UR1268 Biopolymers Interactions Assemblies (BIA), Rue de la Géraudière B.P. 71627, F-44316 Nantes, France
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | | | | |
Collapse
|