1
|
Pradhan T, Chelike DK, Roy D, Pramanik T, Dolui S. Stimuli-Responsive Multiacceptor Conjugated Polymers: Recent Trend and Future Direction. ACS POLYMERS AU 2025; 5:62-79. [PMID: 40226348 PMCID: PMC11986728 DOI: 10.1021/acspolymersau.4c00082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2024] [Revised: 12/09/2024] [Accepted: 01/03/2025] [Indexed: 04/15/2025]
Abstract
Apart from the visual effects, geometric shapes of materials play an important role in their engineering and biomedical applications. Responsive materials-based patient-specific anatomical models provide better insights into the structure and pathology. Polymers are by far the most utilized class of materials for advanced science and technology. Because of these properties, these polymers have been used as functional coatings, thermoplastics, biomedical materials, separators, and binders for Li-ion batteries, fuel cell membranes, piezoelectric devices, high-quality wires and cables, and so on. Reactive to stimuli because of their unusual electrical characteristics and adaptability, stimuli-responsive multiacceptor conjugated polymers have been a prominent focus of materials science study. These polymers combine several electron-accepting units inside their conjugated backbone, resulting in increased functionality and responsiveness to a variety of stimuli. The production, workings, and wide range of applications of stimuli-responsive multiacceptor conjugated polymers are the focus of this review.
Collapse
Affiliation(s)
- Tamanna Pradhan
- Department
of Chemistry, Indian Institute of Technology
Kharagpur, Kharagpur, West Bengal 721302, India
| | - Dinesh Kumar Chelike
- Department
of Chemistry, Rungta College of Engineering
& Technology Bhilai, Kohka, Durg, Chhattisgarh 490024, India
| | - Debarshi Roy
- Jay
FineChem Pvt. Ltd., Vapi, Gujarat 396191, India
| | - Tanay Pramanik
- Department
of Chemistry, Institute of Engineering and Management, University of Engineering and Management Kolkata, University Area, Action area 3,
Newtown, Kolkata 700160, India
| | - Subrata Dolui
- Graduate
School of Advanced Science and Engineering, Hiroshima University, Kagamiyama 1-4-1, Higashihiroshima 739-8527, Japan
| |
Collapse
|
2
|
Hachim D, Hernández‐Cruz O, Foote JEJ, Wang R, Delahaye MW, Stuckey DJ, Feng Z, Wojciechowski JP, Salter LCB, Lin J, Harding SE, Stevens MM. Self-Doped and Biodegradable Glycosaminoglycan-PEDOT Conductive Hydrogels Facilitate Electrical Pacing of iPSC-Derived Cardiomyocytes. Adv Healthc Mater 2025; 14:e2403995. [PMID: 40018808 PMCID: PMC11973950 DOI: 10.1002/adhm.202403995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Revised: 02/04/2025] [Indexed: 03/01/2025]
Abstract
Conductive polymers hold promise in biomedical applications owing to their distinct conductivity characteristics and unique properties. However, incorporating these polymers into biomaterials poses challenges related to mechanical performance, electrical stability, and biodegradation. This study proposes an injectable hydrogel scaffold composed of a self-doped conductive polymer, constituted of a sulfated glycosaminoglycan (GAG) with side chains of PEDOT (poly 3,4-ethylenedioxythiophene). This brush copolymer is synthesized via oxidative polymerization from an EDOT monomer grafted onto the backbone of the sulfated GAG. The GAG backbone offers biodegradability, while sulfate groups act as acidic self-doping agents. Conductive hydrogels form through oxime crosslinking, initially existing as a liquid mixture that undergoes gelation within the tissue, allowing for injectability. The conductive hydrogels show tunable stiffness and gelation kinetics influenced by both concentration and pH, and exhibit adhesive properties. They showcase dual ionic and electronic conductivity, where sulfate groups in the GAG backbone act as doping moieties, enhancing conductivity and electrical stability. These properties of conductive hydrogels are associated with the facilitation of electrical pacing of iPSC-cardiomyocytes. Furthermore, hydrogels exhibit biodegradation and show evidence of biocompatibility, highlighting their potential for diverse biomedical applications.
Collapse
Affiliation(s)
- Daniel Hachim
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
- School of PharmacyFaculty of Chemistry and PharmacyPontifical Catholic University of ChileAV. VICUNA MACKENNA 4860Santiago7820436Chile
| | - Olivia Hernández‐Cruz
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
- National Heart and Lung InstituteImperial College LondonDu Cane RoadLondonW12 0NNUK
| | - James E. J. Foote
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
| | - Richard Wang
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
| | - Matthew W. Delahaye
- National Heart and Lung InstituteImperial College LondonDu Cane RoadLondonW12 0NNUK
| | - Daniel J. Stuckey
- Centre for Advanced Biomedical ImagingUniversity College London72 Huntley StreetLondonWC1E 6DDUK
| | - Zhiping Feng
- Centre for Advanced Biomedical ImagingUniversity College London72 Huntley StreetLondonWC1E 6DDUK
| | - Jonathan P. Wojciechowski
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
- Department of PhysiologyAnatomy and GeneticsDepartment of Engineering ScienceKavli Institute for Nanoscience DiscoveryUniversity of OxfordSherrington RoadOxfordOX1 3QUUK
| | - Luke C. B. Salter
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
| | - Junliang Lin
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
- Department of PhysiologyAnatomy and GeneticsDepartment of Engineering ScienceKavli Institute for Nanoscience DiscoveryUniversity of OxfordSherrington RoadOxfordOX1 3QUUK
| | - Sian E. Harding
- National Heart and Lung InstituteImperial College LondonDu Cane RoadLondonW12 0NNUK
| | - Molly M. Stevens
- Department of MaterialsDepartment of Bioengineering and Institute of Biomedical EngineeringImperial College LondonExhibition RoadLondonSW7 2AZUK
- Department of PhysiologyAnatomy and GeneticsDepartment of Engineering ScienceKavli Institute for Nanoscience DiscoveryUniversity of OxfordSherrington RoadOxfordOX1 3QUUK
| |
Collapse
|
3
|
Robinson KJ, Voelcker NH, Thissen H. Clinical challenges and opportunities related to the biological responses experienced by indwelling and implantable bioelectronic medical devices. Acta Biomater 2025; 193:49-64. [PMID: 39675496 DOI: 10.1016/j.actbio.2024.12.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 12/10/2024] [Accepted: 12/12/2024] [Indexed: 12/17/2024]
Abstract
Implantable electrodes have been utilized for decades to stimulate, sense, or monitor a broad range of biological processes, with examples ranging from glucose monitoring devices to cochlear implants. While the underlying science related to the application of electrodes is a mature field, preclinical and clinical studies have demonstrated that there are still significant challenges in vivo associated with a lack of control over tissue-material interfacial interactions, especially over longer time frames. Herein we discuss the current challenges and opportunities for implantable electrodes and the associated bioelectronic interfaces across the clinical landscape with a focus on emerging technologies and the obstacles of biofouling, microbial colonization, and the foreign body response. Overcoming these challenges is predicted to open the door for a new generation of implantable medical devices and significant associated clinical impact. STATEMENT OF SIGNIFICANCE: Implantable electrodes have been utilised for decades to stimulate, sense, or monitor a broad range of biological processes, with examples ranging from glucose monitoring devices to cochlear implants. Next-generation bioelectronic implantable medical devices promise an explosion of new applications that have until this point in time been impossible to achieve. However, there are several persistent biological challenges hindering the realisation of these new applications. We present a clinical perspective on how these biological challenges have shaped the device market and clinical trial landscape. Specifically, we present statistical breakdowns of current device applications and discuss biofouling, the foreign body response, and microbial colonisation as the main factors that need to be addressed before a new generation of devices can be explored.
Collapse
Affiliation(s)
- Kye J Robinson
- CSIRO Manufacturing, Research Way, Clayton, Victoria 3168, Australia.
| | - Nicolas H Voelcker
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia
| | - Helmut Thissen
- CSIRO Manufacturing, Research Way, Clayton, Victoria 3168, Australia
| |
Collapse
|
4
|
Zhou X, Liu X, Gu Z. Photoresist Development for 3D Printing of Conductive Microstructures via Two-Photon Polymerization. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2409326. [PMID: 39397334 DOI: 10.1002/adma.202409326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Revised: 09/04/2024] [Indexed: 10/15/2024]
Abstract
The advancement of electronic devices necessitates the development of three-dimensional (3D) high-precision conductive microstructures, which have extensive applications in bio-electronic interfaces, soft robots, and electronic skins. Two-photon polymerization (TPP) based 3D printing is a critical technique that offers unparalleled fabrication resolution in 3D space for intricate conductive structures. While substantial progress has been made in this field, this review summarizes recent advances in the 3D printing of conductive microstructures via TPP, mainly focusing on the essential criteria of photoresist resins suitable for TPP. Further preparation strategies of these photoresists and methods for constructing 3D conductive microstructures via TPP are discussed. The application prospects of 3D conductive microstructures in various fields are discussed, highlighting the imperative to advance their additive manufacturing technology. Finally, strategic recommendations are offered to enhance the construction of 3D conductive microstructures using TPP, addressing prevailing challenges and fostering significant advancements in manufacturing technology.
Collapse
Affiliation(s)
- Xin Zhou
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, China
| | - Xiaojiang Liu
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, China
| | - Zhongze Gu
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, China
| |
Collapse
|
5
|
Ershad-Langroudi A, Babazadeh N, Alizadegan F, Mehdi Mousaei S, Moradi G. Polymers for implantable devices. J IND ENG CHEM 2024; 137:61-86. [DOI: 10.1016/j.jiec.2024.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
|
6
|
Fidanovski K, Gu M, Travaglini L, Lauto A, Mawad D. Self-Doping and Self-Acid-Doping of Conjugated Polymer Bioelectronics: The Case for Accuracy in Nomenclature. Adv Healthc Mater 2024; 13:e2302354. [PMID: 37883783 DOI: 10.1002/adhm.202302354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/16/2023] [Indexed: 10/28/2023]
Abstract
Conjugated polymers are enabling the development of flexible bioelectronics, largely driven by their organic nature which facilitates modification and tuning to suit a variety of applications. As organic semiconductors, conjugated polymers require a dopant to exhibit electrical conductivity, which in physiological conditions can result in dopant loss and thereby deterioration in electronic properties. To overcome this challenge, "self-doped" and self-acid-doped conjugated polymers having ionized pendant groups covalently bound to their backbone are being developed. The ionized group in a "self-doped" polymer behaves as the counterion that maintains electroneutrality, while an external dopant is required to induce charge transfer. The ionized group in a self-acid-doped polymer induces charge transfer and behaves as the counterion balancing the charges. Despite their doping processes being different, the two terms, self-doped and self-acid-doped, are often used interchangeably in the literature. Here, the differences are highlighted in the doping mechanisms of self-doped and self-acid-doped polymers, and it is proposed that the term "self-doped" should be replaced by "self-compensated," while reserving the term self-acid-doped for polymers that are intrinsically doped without the need of an external dopant. This is followed by a summary of examples of self-acid-doping in bioelectronics, highlighting their stability in the conductive state under physiological conditions.
Collapse
Affiliation(s)
- Kristina Fidanovski
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Modi Gu
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Lorenzo Travaglini
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Antonio Lauto
- School of Science, Western Sydney University, Locked Bag 1797, Penrith, New South Wales, 2751, Australia
| | - Damia Mawad
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Australian Centre for NanoMedicine, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| |
Collapse
|
7
|
Babangida AA, Uddin A, Stephen KT, Yusuf BA, Zhang L, Ge D. A Roadmap from Functional Materials to Plant Health Monitoring (PHM). Macromol Biosci 2024; 24:e2300283. [PMID: 37815087 DOI: 10.1002/mabi.202300283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 10/05/2023] [Indexed: 10/11/2023]
Abstract
Soft bioelectronics have great potential for the early diagnosis of plant diseases and the mitigation of adverse outcomes such as reduced crop yields and stunted growth. Over the past decade, bioelectronic interfaces have evolved into miniaturized conformal electronic devices that integrate flexible monitoring systems with advanced electronic functionality. This development is largely attributable to advances in materials science, and micro/nanofabrication technology. The approach uses the mechanical and electronic properties of functional materials (polymer substrates and sensing elements) to create interfaces for plant monitoring. In addition to ensuring biocompatibility, several other factors need to be considered when developing these interfaces. These include the choice of materials, fabrication techniques, precision, electrical performance, and mechanical stability. In this review, some of the benefits plants can derive from several of the materials used to develop soft bioelectronic interfaces are discussed. The article describes how they can be used to create biocompatible monitoring devices that can enhance plant growth and health. Evaluation of these devices also takes into account features that ensure their long-term durability, sensitivity, and reliability. This article concludes with a discussion of the development of reliable soft bioelectronic systems for plants, which has the potential to advance the field of bioelectronics.
Collapse
Affiliation(s)
- Abubakar A Babangida
- Institute of Intelligent Flexible Mechatronics, School of Mechanical Engineering, Jiangsu University, Zhenjiang, 212013, P. R. China
| | - Azim Uddin
- Institute for Composites Science Innovation (InCSI), School of Materials Science and Engineering, Zhejiang University, 38 Zheda Road, Hangzhou, 310027, P. R. China
| | - Kukwi Tissan Stephen
- School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, P. R. China
| | - Bashir Adegbemiga Yusuf
- Institute of Intelligent Flexible Mechatronics, School of Mechanical Engineering, Jiangsu University, Zhenjiang, 212013, P. R. China
| | - Liqiang Zhang
- Institute of Intelligent Flexible Mechatronics, School of Mechanical Engineering, Jiangsu University, Zhenjiang, 212013, P. R. China
- Center of Energy Storage Materials & Technology, College of Engineering and Applied Sciences, Jiangsu Key Laboratory of Artificial Functional Materials, National Laboratory of Solid-State Microstructures, and Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing, Jiangsu, 210093, China
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, Jiangnan University, Wuxi, Jiangsu, 214126, China
| | - Daohan Ge
- Institute of Intelligent Flexible Mechatronics, School of Mechanical Engineering, Jiangsu University, Zhenjiang, 212013, P. R. China
| |
Collapse
|
8
|
Zhang X, Zhou C, Hou J, Feng G, Xu Z, Shao Y, Yang C, Xu G. Conjugated Oligoelectrolyte with DNA Affinity for Enhanced Nuclear Imaging and Precise DNA Quantification. BIOSENSORS 2024; 14:105. [PMID: 38392025 PMCID: PMC10887168 DOI: 10.3390/bios14020105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/05/2024] [Accepted: 02/10/2024] [Indexed: 02/24/2024]
Abstract
Precise DNA quantification and nuclear imaging are pivotal for clinical testing, pathological diagnosis, and drug development. The detection and localization of mitochondrial DNA serve as crucial indicators of cellular health. We introduce a novel conjugated oligoelectrolyte (COE) molecule, COE-S3, featuring a planar backbone composed of three benzene rings and terminal side chains. This unique amphiphilic structure endows COE-S3 with exceptional water solubility, a high quantum yield of 0.79, and a significant fluorescence Stokes shift (λex = 366 nm, λem = 476 nm), alongside a specific fluorescence response to DNA. The fluorescence intensity correlates proportionally with DNA concentration. COE-S3 interacts with double-stranded DNA (dsDNA) through an intercalation binding mode, exhibiting a binding constant (K) of 1.32 × 106 M-1. Its amphiphilic nature and strong DNA affinity facilitate its localization within mitochondria in living cells and nuclei in apoptotic cells. Remarkably, within 30 min of COE-S3 staining, cell vitality can be discerned through real-time nuclear fluorescence imaging of apoptotic cells. COE-S3's high DNA selectivity enables quantitative intracellular DNA analysis, providing insights into cell proliferation, differentiation, and growth. Our findings underscore COE-S3, with its strategically designed, shortened planar backbone, as a promising intercalative probe for DNA quantification and nuclear imaging.
Collapse
Affiliation(s)
- Xinmeng Zhang
- Shenzhen Testing Center of Medical Devices, Shenzhen Institute for Drug Control, Shenzhen 518057, China
- College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Cheng Zhou
- Institute of Polymer Optoelectronic Materials and Devices, State Key Laboratory of Luminescent Materials and Devices, South China University of Technology, Guangzhou 510640, China
| | - Jianxun Hou
- Shenzhen Testing Center of Medical Devices, Shenzhen Institute for Drug Control, Shenzhen 518057, China
| | - Gang Feng
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| | - Zhourui Xu
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| | - Yonghong Shao
- College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
| | - Chengbin Yang
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| | - Gaixia Xu
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
9
|
Zhang P, Zhu B, Du P, Travas-Sejdic J. Electrochemical and Electrical Biosensors for Wearable and Implantable Electronics Based on Conducting Polymers and Carbon-Based Materials. Chem Rev 2024; 124:722-767. [PMID: 38157565 DOI: 10.1021/acs.chemrev.3c00392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Bioelectronic devices are designed to translate biological information into electrical signals and vice versa, thereby bridging the gap between the living biological world and electronic systems. Among different types of bioelectronics devices, wearable and implantable biosensors are particularly important as they offer access to the physiological and biochemical activities of tissues and organs, which is significant in diagnosing and researching various medical conditions. Organic conducting and semiconducting materials, including conducting polymers (CPs) and graphene and carbon nanotubes (CNTs), are some of the most promising candidates for wearable and implantable biosensors. Their unique electrical, electrochemical, and mechanical properties bring new possibilities to bioelectronics that could not be realized by utilizing metals- or silicon-based analogues. The use of organic- and carbon-based conductors in the development of wearable and implantable biosensors has emerged as a rapidly growing research field, with remarkable progress being made in recent years. The use of such materials addresses the issue of mismatched properties between biological tissues and electronic devices, as well as the improvement in the accuracy and fidelity of the transferred information. In this review, we highlight the most recent advances in this field and provide insights into organic and carbon-based (semi)conducting materials' properties and relate these to their applications in wearable/implantable biosensors. We also provide a perspective on the promising potential and exciting future developments of wearable/implantable biosensors.
Collapse
Affiliation(s)
- Peikai Zhang
- Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand
| | - Bicheng Zhu
- Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand
| | - Jadranka Travas-Sejdic
- Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand
| |
Collapse
|
10
|
Wu W, Yu S, Forbes DS, Jiang H, Ahmed M, Mei J. Efficient and Modular Biofunctionalization of Thiophene-Based Conjugated Polymers through Embedded Latent Disulfide. J Am Chem Soc 2024; 146:578-585. [PMID: 38157440 DOI: 10.1021/jacs.3c10321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Biofunctionalized conjugated polymers (i.e., carrying enzymes, antibodies, and nucleic acids) are of great interest for many biological applications, yet efficient biofunctionalization of conjugated polymers under biocompatible conditions is challenging. We report a facile strategy to make biofunctionalized conjugated polymers through thiol-ene chemistry with embedded latent disulfide functional groups. This is made possible through the design of a cyclic disulfide-containing dioxythiophene, which can be integrated into a series of conjugated polymers via acid-catalyzed chain-growth polymerization. The utility of such a biofunctionalized polymer with glucose oxidase has been examined in organic electrochemical transistors for the selective sensing of glucose. This work provides a venue for the creation of biofunctional organic semiconductors.
Collapse
Affiliation(s)
- Wenting Wu
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Songyan Yu
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Dylan S Forbes
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Hanning Jiang
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Mustafa Ahmed
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jianguo Mei
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
11
|
Almasri RM, Ladouceur F, Mawad D, Esrafilzadeh D, Firth J, Lehmann T, Poole-Warren LA, Lovell NH, Al Abed A. Emerging trends in the development of flexible optrode arrays for electrophysiology. APL Bioeng 2023; 7:031503. [PMID: 37692375 PMCID: PMC10491464 DOI: 10.1063/5.0153753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 08/08/2023] [Indexed: 09/12/2023] Open
Abstract
Optical-electrode (optrode) arrays use light to modulate excitable biological tissues and/or transduce bioelectrical signals into the optical domain. Light offers several advantages over electrical wiring, including the ability to encode multiple data channels within a single beam. This approach is at the forefront of innovation aimed at increasing spatial resolution and channel count in multichannel electrophysiology systems. This review presents an overview of devices and material systems that utilize light for electrophysiology recording and stimulation. The work focuses on the current and emerging methods and their applications, and provides a detailed discussion of the design and fabrication of flexible arrayed devices. Optrode arrays feature components non-existent in conventional multi-electrode arrays, such as waveguides, optical circuitry, light-emitting diodes, and optoelectronic and light-sensitive functional materials, packaged in planar, penetrating, or endoscopic forms. Often these are combined with dielectric and conductive structures and, less frequently, with multi-functional sensors. While creating flexible optrode arrays is feasible and necessary to minimize tissue-device mechanical mismatch, key factors must be considered for regulatory approval and clinical use. These include the biocompatibility of optical and photonic components. Additionally, material selection should match the operating wavelength of the specific electrophysiology application, minimizing light scattering and optical losses under physiologically induced stresses and strains. Flexible and soft variants of traditionally rigid photonic circuitry for passive optical multiplexing should be developed to advance the field. We evaluate fabrication techniques against these requirements. We foresee a future whereby established telecommunications techniques are engineered into flexible optrode arrays to enable unprecedented large-scale high-resolution electrophysiology systems.
Collapse
Affiliation(s)
- Reem M. Almasri
- Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia
| | | | - Damia Mawad
- School of Materials Science and Engineering, UNSW, Sydney, NSW 2052, Australia
| | - Dorna Esrafilzadeh
- Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia
| | - Josiah Firth
- Australian National Fabrication Facility, UNSW, Sydney, NSW 2052, Australia
| | - Torsten Lehmann
- School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052, Australia
| | | | | | - Amr Al Abed
- Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia
| |
Collapse
|
12
|
Sun F, Jiang H, Wang H, Zhong Y, Xu Y, Xing Y, Yu M, Feng LW, Tang Z, Liu J, Sun H, Wang H, Wang G, Zhu M. Soft Fiber Electronics Based on Semiconducting Polymer. Chem Rev 2023; 123:4693-4763. [PMID: 36753731 DOI: 10.1021/acs.chemrev.2c00720] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
Abstract
Fibers, originating from nature and mastered by human, have woven their way throughout the entire history of human civilization. Recent developments in semiconducting polymer materials have further endowed fibers and textiles with various electronic functions, which are attractive in applications such as information interfacing, personalized medicine, and clean energy. Owing to their ability to be easily integrated into daily life, soft fiber electronics based on semiconducting polymers have gained popularity recently for wearable and implantable applications. Herein, we present a review of the previous and current progress in semiconducting polymer-based fiber electronics, particularly focusing on smart-wearable and implantable areas. First, we provide a brief overview of semiconducting polymers from the viewpoint of materials based on the basic concepts and functionality requirements of different devices. Then we analyze the existing applications and associated devices such as information interfaces, healthcare and medicine, and energy conversion and storage. The working principle and performance of semiconducting polymer-based fiber devices are summarized. Furthermore, we focus on the fabrication techniques of fiber devices. Based on the continuous fabrication of one-dimensional fiber and yarn, we introduce two- and three-dimensional fabric fabricating methods. Finally, we review challenges and relevant perspectives and potential solutions to address the related problems.
Collapse
Affiliation(s)
- Fengqiang Sun
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
- Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
| | - Hao Jiang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Haoyu Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Yueheng Zhong
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Yiman Xu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Yi Xing
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Muhuo Yu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
- Shanghai Key Laboratory of Lightweight Structural Composites, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Liang-Wen Feng
- Key Laboratory of Green Chemistry & Technology, Ministry of Education, College of Chemistry, Sichuan University, Chengdu 610065, China
| | - Zheng Tang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
- Center for Advanced Low-dimension Materials, Donghua University, Shanghai 201620, China
| | - Jun Liu
- National Key Laboratory on Electromagnetic Environment Effects and Electro-Optical Engineering, Nanjing 210007, China
| | - Hengda Sun
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Hongzhi Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Gang Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Meifang Zhu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| |
Collapse
|
13
|
DiTullio BT, Savagian LR, Bardagot O, De Keersmaecker M, Österholm AM, Banerji N, Reynolds JR. Effects of Side-Chain Length and Functionality on Polar Poly(dioxythiophene)s for Saline-Based Organic Electrochemical Transistors. J Am Chem Soc 2023; 145:122-134. [PMID: 36563183 DOI: 10.1021/jacs.2c08850] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Understanding the impact of side chains on the aqueous redox properties of conjugated polymers is crucial to unlocking their potential in bioelectrochemical devices, such as organic electrochemical transistors (OECTs). Here, we report a series of polar propylenedioxythiophene-based copolymers functionalized with glyme side chains of varying lengths as well as an analogue with short hydroxyl side chains. We show that long polar side chains are not required for achieving high volumetric capacitance (C*), as short hydroxy substituents can afford facile doping and high C* in saline-based electrolytes. Furthermore, we demonstrate that varying the length of the polar glyme chains leads to subtle changes in material properties. Increasing the length of glyme side chain is generally associated with an enhancement in OECT performance, doping kinetics, and stability, with the polymer bearing the longest side chains exhibiting the highest performance ([μC*]OECT = 200 ± 8 F cm-1 V-1 s-1). The origin of this performance enhancement is investigated in different device configurations using in situ techniques (e.g., time-resolved spectroelectrochemistry and chronoamperometry). These studies suggest that the performance improvement is not due to significant changes in C* but rather due to variations in the inferred mobility. Through a thorough comparison of two different architectures, we demonstrate that device geometry can obfuscate the benchmarking of OECT active channel materials, likely due to contact resistance effects. By complementing all electrochemical and spectroscopic experiments with in situ measurements performed within a planar OECT device configuration, this work seeks to unambiguously assign material design principles to fine-tune the properties of poly(dioxythiophene)s relevant for application in OECTs.
Collapse
Affiliation(s)
- Brandon T DiTullio
- School of Chemistry and Biochemistry, Center for Organic Photonics and Electronics, Georgia Tech Polymer Network, Georgia Institute of Technology, Atlanta, Georgia30332, United States
| | - Lisa R Savagian
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia30332, United States
| | - Olivier Bardagot
- Department of Chemistry, Biochemistry and Pharmaceutical Sciences (DCBP), University of Bern, Bern3012, Switzerland
| | - Michel De Keersmaecker
- School of Chemistry and Biochemistry, Center for Organic Photonics and Electronics, Georgia Tech Polymer Network, Georgia Institute of Technology, Atlanta, Georgia30332, United States
| | - Anna M Österholm
- School of Chemistry and Biochemistry, Center for Organic Photonics and Electronics, Georgia Tech Polymer Network, Georgia Institute of Technology, Atlanta, Georgia30332, United States
| | - Natalie Banerji
- Department of Chemistry, Biochemistry and Pharmaceutical Sciences (DCBP), University of Bern, Bern3012, Switzerland
| | - John R Reynolds
- School of Chemistry and Biochemistry, Center for Organic Photonics and Electronics, Georgia Tech Polymer Network, Georgia Institute of Technology, Atlanta, Georgia30332, United States.,School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia30332, United States
| |
Collapse
|
14
|
Shafique H, de Vries J, Strauss J, Khorrami Jahromi A, Siavash Moakhar R, Mahshid S. Advances in the Translation of Electrochemical Hydrogel-Based Sensors. Adv Healthc Mater 2023; 12:e2201501. [PMID: 36300601 DOI: 10.1002/adhm.202201501] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 09/26/2022] [Indexed: 02/03/2023]
Abstract
Novel biomaterials for bio- and chemical sensing applications have gained considerable traction in the diagnostic community with rising trends of using biocompatible and lowly cytotoxic material. Hydrogel-based electrochemical sensors have become a promising candidate for their swellable, nano-/microporous, and aqueous 3D structures capable of immobilizing catalytic enzymes, electroactive species, whole cells, and complex tissue models, while maintaining tunable mechanical properties in wearable and implantable applications. With advances in highly controllable fabrication and processability of these novel biomaterials, the possibility of bio-nanocomposite hydrogel-based electrochemical sensing presents a paradigm shift in the development of biocompatible, "smart," and sensitive health monitoring point-of-care devices. Here, recent advances in electrochemical hydrogels for the detection of biomarkers in vitro, in situ, and in vivo are briefly reviewed to demonstrate their applicability in ideal conditions, in complex cellular environments, and in live animal models, respectively, to provide a comprehensive assessment of whether these biomaterials are ready for point-of-care translation and biointegration. Sensors based on conductive and nonconductive polymers are presented, with highlights of nano-/microstructured electrodes that provide enhanced sensitivity and selectivity in biocompatible matrices. An outlook on current challenges that shall be addressed for the realization of truly continuous real-time sensing platforms is also presented.
Collapse
Affiliation(s)
- Houda Shafique
- Department of Bioengineering, McGill University, Montreal, QC, H3A 0E9, Canada
| | - Justin de Vries
- Department of Bioengineering, McGill University, Montreal, QC, H3A 0E9, Canada
| | - Julia Strauss
- Department of Bioengineering, McGill University, Montreal, QC, H3A 0E9, Canada
| | | | | | - Sara Mahshid
- Department of Bioengineering, McGill University, Montreal, QC, H3A 0E9, Canada
| |
Collapse
|
15
|
Fassina D, Costa CM, Longobardi S, Karabelas E, Plank G, Harding SE, Niederer SA. Modelling the interaction between stem cells derived cardiomyocytes patches and host myocardium to aid non-arrhythmic engineered heart tissue design. PLoS Comput Biol 2022; 18:e1010030. [PMID: 35363778 PMCID: PMC9007348 DOI: 10.1371/journal.pcbi.1010030] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 04/13/2022] [Accepted: 03/17/2022] [Indexed: 11/18/2022] Open
Abstract
Application of epicardial patches constructed from human-induced pluripotent stem cell- derived cardiomyocytes (hiPSC-CMs) has been proposed as a long-term therapy to treat scarred hearts post myocardial infarction (MI). Understanding electrical interaction between engineered heart tissue patches (EHT) and host myocardium represents a key step toward a successful patch engraftment. EHT retain different electrical properties with respect to the host heart tissue due to the hiPSC-CMs immature phenotype, which may lead to increased arrhythmia risk. We developed a modelling framework to examine the influence of patch design on electrical activation at the engraftment site. We performed an in silico investigation of different patch design approaches to restore pre-MI activation properties and evaluated the associated arrhythmic risk. We developed an in silico cardiac electrophysiology model of a transmural cross section of host myocardium. The model featured an infarct region, an epicardial patch spanning the infarct region and a bath region. The patch is modelled as a layer of hiPSC-CM, combined with a layer of conductive polymer (CP). Tissue and patch geometrical dimensions and conductivities were incorporated through 10 modifiable model parameters. We validated our model against 4 independent experimental studies and showed that it can qualitatively reproduce their findings. We performed a global sensitivity analysis (GSA) to isolate the most important parameters, showing that the stimulus propagation is mainly governed by the scar depth, radius and conductivity when the scar is not transmural, and by the EHT patch conductivity when the scar is transmural. We assessed the relevance of small animal studies to humans by comparing simulations of rat, rabbit and human myocardium. We found that stimulus propagation paths and GSA sensitivity indices are consistent across species. We explored which EHT design variables have the potential to restore physiological propagation. Simulations predict that increasing EHT conductivity from 0.28 to 1-1.1 S/m recovered physiological activation in rat, rabbit and human. Finally, we assessed arrhythmia risk related to increasing EHT conductivity and tested increasing the EHT Na+ channel density as an alternative strategy to match healthy activation. Our results revealed a greater arrhythmia risk linked to increased EHT conductivity compared to increased Na+ channel density. We demonstrated that our modeling framework could capture the interaction between host and EHT patches observed in in vitro experiments. We showed that large (patch and tissue dimensions) and small (cardiac myocyte electrophysiology) scale differences between small animals and humans do not alter EHT patch effect on infarcted tissue. Our model revealed that only when the scar is transmural do EHT properties impact activation times and isolated the EHT conductivity as the main parameter influencing propagation. We predicted that restoring physiological activation by tuning EHT conductivity is possible but may promote arrhythmic behavior. Finally, our model suggests that acting on hiPSC-CMs low action potential upstroke velocity and lack of IK1 may restore pre-MI activation while not promoting arrhythmia.
Collapse
Affiliation(s)
- Damiano Fassina
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Caroline M. Costa
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Stefano Longobardi
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Elias Karabelas
- Institute of Mathematics & Scientific Computing, University of Graz, Graz, Austria
| | - Gernot Plank
- Gottfried Schatz Research Center (for Cell Signaling, Metabolism and Aging), Division Biophysics, Medical University of Graz, Graz, Austria
| | - Sian E. Harding
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Steven A. Niederer
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| |
Collapse
|
16
|
Peng Z, Ye L, Ade H. Understanding, quantifying, and controlling the molecular ordering of semiconducting polymers: from novices to experts and amorphous to perfect crystals. MATERIALS HORIZONS 2022; 9:577-606. [PMID: 34878458 DOI: 10.1039/d0mh00837k] [Citation(s) in RCA: 50] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Molecular packing and texture of semiconducting polymers are often critical to the performance of devices using these materials. Although frameworks exist to quantify the ordering, interpretations are often just qualitative, resulting in imprecise use of terminology. Here, we reemphasize the significance of quantifying molecular ordering in terms of degree of crystallinity (volume fractions that are ordered) and quality of ordering and their relation to the size scale of an ordered region. We are motivated in part by our own imprecise and inconsistent use of terminology in the past, as well as the need to have a primer or tutorial reference to teach new group members. We strive to develop and use consistent terminology with regards to crystallinity, semicrystallinity, paracrystallinity, and related characteristics. To account for vastly different quality of ordering along different directions, we classify paracrystals into 2D and 3D paracrystals and use paracrystallite to describe the spatial extent of molecular ordering in 1-10 nm. We show that a deeper understanding of molecular ordering can be achieved by combining grazing-incidence wide-angle X-ray scattering and differential scanning calorimetry, even though not all aspects of these measurements are consistent, and some classification appears to be method dependent. We classify a broad range of representative polymers under common processing conditions into five categories based on the quantitative analysis of the paracrystalline disorder parameter (g) and thermal transitions. A small database is presented for 13 representative conjugated and insulating polymers ranging from amorphous to semi-paracrystalline. Finally, we outline the challenges to rationally design more perfect polymer crystals and propose a new molecular design approach that envisions conceptual molecular grafting that is akin to strained and unstrained hetero-epitaxy in classic (compound) semiconductors thin film growth.
Collapse
Affiliation(s)
- Zhengxing Peng
- Department of Physics and Organic and Carbon Electronics Laboratories (ORaCEL), North Carolina State University, Raleigh, North Carolina 27695, USA.
| | - Long Ye
- Department of Physics and Organic and Carbon Electronics Laboratories (ORaCEL), North Carolina State University, Raleigh, North Carolina 27695, USA.
| | - Harald Ade
- Department of Physics and Organic and Carbon Electronics Laboratories (ORaCEL), North Carolina State University, Raleigh, North Carolina 27695, USA.
| |
Collapse
|
17
|
Balancing the biocompatibility and bacterial resistance of polypyrrole by optimized silver incorporation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2022; 134:112701. [DOI: 10.1016/j.msec.2022.112701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 01/21/2022] [Accepted: 02/04/2022] [Indexed: 11/19/2022]
|
18
|
Su X, Liu R, Li Y, Han T, Zhang Z, Niu N, Kang M, Fu S, Wang D, Wang D, Tang BZ. Aggregation-Induced Emission-Active Poly(phenyleneethynylene)s for Fluorescence and Raman Dual-Modal Imaging and Drug-Resistant Bacteria Killing. Adv Healthc Mater 2021; 10:e2101167. [PMID: 34606177 DOI: 10.1002/adhm.202101167] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 09/14/2021] [Indexed: 12/14/2022]
Abstract
Poly(phenyleneethynylene) (PPE) is a widely used functional conjugated polymer with applications ranging from organic optoelectronics and fluorescence sensors to optical imaging and theranostics. However, the fluorescence efficiency of PPE in aggregate states is generally not as good as their solution states, which greatly compromises their performance in fluorescence-related applications. Herein, a series of PPE derivatives with typical aggregation-induced emission (AIE) properties is designed and synthesized. In these PPEs, the diethylamino-substituted tetraphenylethene units function as the long-wavelength AIE source and the alkyl side chains serve as the functionalization site. The obtained AIE-active PPEs with large π-conjugation show strong aggregate-state fluorescence, interesting self-assembly behaviors, inherently enhanced alkyne vibrations in the Raman-silent region of cells, and efficient antibacterial activities. The PPE nanoparticles with good cellular uptake capability can clearly and sensitively visualize the tumor region and residual tumors via their fluorescence and Raman signals, respectively, to benefit the precise tumor resection surgery. After post-functionalization, the obtained PPE-based polyelectrolyte can preferentially image bacteria over mammalian cells and possesses efficient photodynamic killing capability against Gram-positive and drug-resistant bacteria. This work provides a feasible design strategy for developing functional conjugated polymers with multimodal imaging capability as well as photodynamic antimicrobial ability.
Collapse
Affiliation(s)
- Xiang Su
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
- Department of Chemistry Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction The Hong Kong University of Science and Technology Clear Water Bay Kowloon Hong Kong 999077 China
| | - Ruihua Liu
- State Key Laboratory of Medicinal Chemical Biology and College of Life Sciences Nankai University Tianjin 300071 China
| | - Ying Li
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
| | - Ting Han
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
| | - Zhijun Zhang
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
| | - Niu Niu
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
| | - Miaomiao Kang
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
| | - Shuang Fu
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
| | - Deliang Wang
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 China
| | - Dong Wang
- Center for AIE Research Shenzhen Key Laboratory of Polymer Science and Technology Guangdong Research Center for Interfacial Engineering of Functional Materials College of Materials Science and Engineering Shenzhen University Shenzhen 518060 China
| | - Ben Zhong Tang
- Department of Chemistry Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction The Hong Kong University of Science and Technology Clear Water Bay Kowloon Hong Kong 999077 China
- Shenzhen Institute of Aggregate Science and Technology School of Science and Engineering The Chinese University of Hong Kong Shenzhen Guangdong 518172 China
| |
Collapse
|
19
|
Qi J, Su G, Li Z. Gel-Based Luminescent Conductive Materials and Their Applications in Biosensors and Bioelectronics. MATERIALS (BASEL, SWITZERLAND) 2021; 14:6759. [PMID: 34832161 PMCID: PMC8621303 DOI: 10.3390/ma14226759] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 10/31/2021] [Accepted: 11/04/2021] [Indexed: 12/27/2022]
Abstract
The gel is an ideal platform for fabricating materials for bio-related applications due to its good biocompatibility, adjustable mechanical strength, and flexible and diversified functionalization. In recent decades, gel-based luminescent conductive materials that possess additional luminescence and conductivity simultaneously advanced applications in biosensors and bioelectronics. Herein, a comprehensive overview of gel-based luminescent conductive materials is summarized in this review. Gel-based luminescent conductive materials are firstly outlined, highlighting their fabrication methods, network structures, and functions. Then, their applications in biosensors and bioelectronics fields are illustrated. Finally, challenges and future perspectives of this emerging field are discussed with the hope of inspire additional ideas.
Collapse
Affiliation(s)
- Jiajin Qi
- Institute of Engineering Medicine, Beijing Institute of Technology, Beijing 100081, China; (J.Q.); (G.S.)
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, Beijing Institute of Technology, Beijing 100081, China
| | - Gongmeiyue Su
- Institute of Engineering Medicine, Beijing Institute of Technology, Beijing 100081, China; (J.Q.); (G.S.)
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, Beijing Institute of Technology, Beijing 100081, China
| | - Zhao Li
- Institute of Engineering Medicine, Beijing Institute of Technology, Beijing 100081, China; (J.Q.); (G.S.)
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
20
|
Wolf CM, Guio L, Scheiwiller S, Pakhnyuk V, Luscombe C, Pozzo LD. Strategies for the Development of Conjugated Polymer Molecular Dynamics Force Fields Validated with Neutron and X-ray Scattering. ACS POLYMERS AU 2021; 1:134-152. [PMID: 36855657 PMCID: PMC9954299 DOI: 10.1021/acspolymersau.1c00027] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Conjugated polymers (CPs) enable a wide range of lightweight, lower cost, and flexible organic electronic devices, but a thorough understanding of relationships between molecular structure and dynamics and electronic performance is critical for improved device efficiencies and for new technologies. Molecular dynamics (MD) simulations offer in silico insight into this relationship, but their accuracy relies on the approach used to develop the model's parameters or force field (FF). In this Perspective, we first review current FFs for CPs and find that most of the models implement an arduous reparameterization of inter-ring torsion potentials and partial charges of classical FFs. However, there are few FFs outside of simple CP molecules, e.g., polythiophenes, that have been developed over the last two decades. There is also limited reparameterization of other parameters, such as nonbonded Lennard-Jones interactions, which we find to be directly influenced by conjugation in these materials. We further provide a discussion on experimental validation of MD FFs, with emphasis on neutron and X-ray scattering. We define multiple ways in which various scattering methods can be directly compared to results of MD simulations, providing a powerful experimental validation metric of local structure and dynamics at relevant length and time scales to charge transport mechanisms in CPs. Finally, we offer a perspective on the use of neutron scattering with machine learning to enable high-throughput parametrization of accurate and experimentally validated CP FFs enabled not only by the ongoing advancements in computational chemistry, data science, and high-performance computing but also using oligomers as proxies for longer polymer chains during FF development.
Collapse
Affiliation(s)
- Caitlyn M. Wolf
- Department
of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States,Center
for Neutron Research, Stop 6102, National
Institute of Standards and Technology, Gaithersburg, Maryland 20889-6102, United States,
| | - Lorenzo Guio
- Department
of Material Science and Engineering, University
of Washington, Box 352120, Seattle, Washington 98195-2120, United States
| | - Sage Scheiwiller
- Department
of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States
| | - Viktoria Pakhnyuk
- Department
of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, United States
| | - Christine Luscombe
- Department
of Material Science and Engineering, University
of Washington, Box 352120, Seattle, Washington 98195-2120, United States,Department
of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, United States
| | - Lilo D. Pozzo
- Department
of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States,
| |
Collapse
|
21
|
Samal S, Thompson BC. Influence of Alkyl Chain Spacer Length on the Charge Carrier Mobility of Isotactic Poly( N-carbazolylalkyl acrylates). ACS Macro Lett 2021; 10:720-726. [PMID: 35549095 DOI: 10.1021/acsmacrolett.1c00249] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In the search for semiconducting polymer alternatives to conjugated polymers, stereoregular nonconjugated pendant electroactive polymers (NCPEPs) have recently shown competitive hole mobilities with conjugated polymers and a dramatic increase in mobility relative to atactic analogues. Here we investigate one of the key structural variables of NCPEPs: the flexible alkyl spacer that separates the electroactive pendant from the backbone. We investigate a straightforward postpolymerization functionalization synthetic method to synthesize such polymers with high isotacticity using poly(N-carbazolylalkyl acrylate) as a model system, where the alkyl chain spacer in the NCPEPs is varied from 2 to 12 carbons. We observed that the hole mobility increased from the two-carbon spacer, resulting in the highest mobility upon thermal annealing with a four-carbon spacer for 75% isotactic polymers and with a six-carbon spacer for 87% isotactic polymers. As such, we have demonstrated an important role of the spacer chain in influencing mobility. For all spacer lengths, higher mobilities were measured with the more isotactic polymer. While physical characterization of the largely amorphous polymers yielded little insight into the structure-function relationships, DFT and MD simulations indicated helical structures for the polymers where intermolecular short-range π-stacking is observed and is affected by spacer chain length. This work demonstrates that both the degree of stereoregularity and the spacer chain length play a role in determining the hole mobility in NCPEPs.
Collapse
Affiliation(s)
- Sanket Samal
- Department of Chemistry, Loker Hydrocarbon Research Institute, University of Southern California, Los Angeles, California 90089-1661, United States
| | - Barry C Thompson
- Department of Chemistry, Loker Hydrocarbon Research Institute, University of Southern California, Los Angeles, California 90089-1661, United States
| |
Collapse
|
22
|
Abstract
Flexible bioelectronics have promising applications in electronic skin, wearable devices, biomedical electronics, etc. Hydrogels have unique advantages for bioelectronics due to their tissue-like mechanical properties and excellent biocompatibility. Particularly, conductive and tissue adhesive hydrogels can self-adhere to bio-tissues and have great potential in implantable wearable bioelectronics. This review focuses on the recent progress in tissue adhesive hydrogel bioelectronics, including the mechanism and preparation of tissue adhesive hydrogels, the fabrication strategies of conductive hydrogels, and tissue adhesive hydrogel bioelectronics and applications. Some perspectives on tissue adhesive hydrogel bioelectronics are provided at the end of the review.
Collapse
Affiliation(s)
- Shengnan Li
- Key Laboratory of Polymeric Composite and Functional Materials of Ministry of Education, Guangdong Functional Biomaterials Engineering Technology Research Center, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, School of Materials Science and Engineering, Sun Yat-sen University, 135 Xingang Road West, Guangzhou 510275, China.
| | - Yang Cong
- College of Materials Science and Chemical Engineering, Ningbo University of Technology, Ningbo 315201, China
| | - Jun Fu
- Key Laboratory of Polymeric Composite and Functional Materials of Ministry of Education, Guangdong Functional Biomaterials Engineering Technology Research Center, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, School of Materials Science and Engineering, Sun Yat-sen University, 135 Xingang Road West, Guangzhou 510275, China.
| |
Collapse
|
23
|
Electroactive Polymeric Composites to Mimic the Electromechanical Properties of Myocardium in Cardiac Tissue Repair. Gels 2021; 7:gels7020053. [PMID: 34062741 PMCID: PMC8162334 DOI: 10.3390/gels7020053] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/26/2021] [Accepted: 04/28/2021] [Indexed: 12/12/2022] Open
Abstract
Due to the limited regenerative capabilities of cardiomyocytes, incidents of myocardial infarction can cause permanent damage to native myocardium through the formation of acellular, non-conductive scar tissue during wound repair. The generation of scar tissue in the myocardium compromises the biomechanical and electrical properties of the heart which can lead to further cardiac problems including heart failure. Currently, patients suffering from cardiac failure due to scarring undergo transplantation but limited donor availability and complications (i.e., rejection or infectious pathogens) exclude many individuals from successful transplant. Polymeric tissue engineering scaffolds provide an alternative approach to restore normal myocardium structure and function after damage by acting as a provisional matrix to support cell attachment, infiltration and stem cell delivery. However, issues associated with mechanical property mismatch and the limited electrical conductivity of these constructs when compared to native myocardium reduces their clinical applicability. Therefore, composite polymeric scaffolds with conductive reinforcement components (i.e., metal, carbon, or conductive polymers) provide tunable mechanical and electroactive properties to mimic the structure and function of natural myocardium in force transmission and electrical stimulation. This review summarizes recent advancements in the design, synthesis, and implementation of electroactive polymeric composites to better match the biomechanical and electrical properties of myocardial tissue.
Collapse
|
24
|
Wolf CM, Guio L, Scheiwiller SC, O’Hara RP, Luscombe CK, Pozzo LD. Blend Morphology in Polythiophene–Polystyrene Composites from Neutron and X-ray Scattering. Macromolecules 2021. [DOI: 10.1021/acs.macromol.0c02512] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Caitlyn M. Wolf
- Department of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States
| | - Lorenzo Guio
- Department of Material Science and Engineering, University of Washington, Box 352120, Seattle, Washington 98195-2120, United States
| | - Sage C. Scheiwiller
- Department of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States
| | - Ryan P. O’Hara
- Department of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States
| | - Christine K. Luscombe
- Department of Material Science and Engineering, University of Washington, Box 352120, Seattle, Washington 98195-2120, United States
| | - Lilo D. Pozzo
- Department of Chemical Engineering, University of Washington, Box 351750, Seattle, Washington 98195-1750, United States
| |
Collapse
|
25
|
Collier GS, Wilkins R, Tomlinson AL, Reynolds JR. Exploring Isomeric Effects on Optical and Electrochemical Properties of Red/Orange Electrochromic Polymers. Macromolecules 2021. [DOI: 10.1021/acs.macromol.0c02719] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Graham S. Collier
- School of Chemistry and Biochemistry, School of Materials Science and Engineering, Center for Organic Photonics and Electronics, Georgia Tech Polymer Network, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
- Department of Chemistry and Biochemistry, Kennesaw State University, Kennesaw, Georgia 30144, United States
| | - Riley Wilkins
- Department of Chemistry and Biochemistry, University of North Georgia, Dahlonega, Georgia 30597, United States
| | - Aimée L. Tomlinson
- Department of Chemistry and Biochemistry, University of North Georgia, Dahlonega, Georgia 30597, United States
| | - John R. Reynolds
- School of Chemistry and Biochemistry, School of Materials Science and Engineering, Center for Organic Photonics and Electronics, Georgia Tech Polymer Network, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
26
|
Puiggalí-Jou A, Ordoño J, Del Valle LJ, Pérez-Amodio S, Engel E, Alemán C. Tuning multilayered polymeric self-standing films for controlled release of L-lactate by electrical stimulation. J Control Release 2021; 330:669-683. [PMID: 33388340 DOI: 10.1016/j.jconrel.2020.12.049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/22/2020] [Accepted: 12/24/2020] [Indexed: 12/30/2022]
Abstract
We examine different approaches for the controlled release of L-lactate, which is a signaling molecule that participates in tissue remodeling and regeneration, such as cardiac and muscle tissue. Robust, flexible, and self-supported 3-layers films made of two spin-coated poly(lactic acid) (PLA) layers separated by an electropolymerized poly(3,4-ethylenedioxythiophene) (PEDOT) layer, are used as loading and delivery systems. Films with outer layers prepared using homochiral PLA and with nanoperforations of diameter 146 ± 70 experience more bulk erosion, which also contributes to the release of L-lactic acid, than those obtained using heterochiral PLA and with nanoperforations of diameter 66 ± 24. Moreover, the release of L-lactic acid as degradation product is accelerated by applying biphasic electrical pulses. The four approaches used for loading extra L-lactate in the 3-layered films were: incorporation of L-lactate at the intermediate PEDOT layer as primary dopant agent using (1) organic or (2) basic water solutions as reaction media; (3) substitution at the PEDOT layer of the ClO4- dopant by L-lactate using de-doping and re-doping processes; and (4) loading of L-lactate at the outer PLA layers during the spin-coating process. Electrical stimuli were applied considering biphasic voltage pulses and constant voltages (both negative and positive). Results indicate that the approach used to load the L-lactate has a very significant influence in the release regulation process, affecting the concentration of released L-lactate up to two orders of magnitude. Among the tested approaches, the one based on the utilization of the outer layers for loading, approach (4), can be proposed for situations requiring prolonged and sustained L-lactate release over time. The biocompatibility and suitability of the engineered films for cardiac tissue engineering has also been confirmed using cardiac cells.
Collapse
Affiliation(s)
- Anna Puiggalí-Jou
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany 10-14, Ed. I2, 08019 Barcelona, Spain; Barcelona Research Center for Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Eduard Maristany 10-14, Ed. C, 08019 Barcelona, Spain.
| | - Jesús Ordoño
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain; CIBER en Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, Zaragoza 50018, Spain
| | - Luis J Del Valle
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany 10-14, Ed. I2, 08019 Barcelona, Spain; Barcelona Research Center for Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Eduard Maristany 10-14, Ed. C, 08019 Barcelona, Spain
| | - Soledad Pérez-Amodio
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain; CIBER en Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, Zaragoza 50018, Spain; Materials Science and Metallurgical Engineering, EEBE, Universitat Politècnica de Catalunya (UPC), C/Eduard Maristany 10-14, 08019 Barcelona, Spain
| | - Elisabeth Engel
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain; CIBER en Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, Zaragoza 50018, Spain; Materials Science and Metallurgical Engineering, EEBE, Universitat Politècnica de Catalunya (UPC), C/Eduard Maristany 10-14, 08019 Barcelona, Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany 10-14, Ed. I2, 08019 Barcelona, Spain; Barcelona Research Center for Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Eduard Maristany 10-14, Ed. C, 08019 Barcelona, Spain; Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain.
| |
Collapse
|
27
|
Gibney S, Hicks JM, Robinson A, Jain A, Sanjuan-Alberte P, Rawson FJ. Toward nanobioelectronic medicine: Unlocking new applications using nanotechnology. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 13:e1693. [PMID: 33442962 DOI: 10.1002/wnan.1693] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 11/29/2020] [Accepted: 12/14/2020] [Indexed: 12/11/2022]
Abstract
Bioelectronic medicine aims to interface electronic technology with biological components and design more effective therapeutic and diagnostic tools. Advances in nanotechnology have moved the field forward improving the seamless interaction between biological and electronic components. In the lab many of these nanobioelectronic devices have the potential to improve current treatment approaches, including those for cancer, cardiovascular disorders, and disease underpinned by malfunctions in neuronal electrical communication. While promising, many of these devices and technologies require further development before they can be successfully applied in a clinical setting. Here, we highlight recent work which is close to achieving this goal, including discussion of nanoparticles, carbon nanotubes, and nanowires for medical applications. We also look forward toward the next decade to determine how current developments in nanotechnology could shape the growing field of bioelectronic medicine. This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Nanotechnology Approaches to Biology > Nanoscale Systems in Biology Diagnostic Tools > Biosensing.
Collapse
Affiliation(s)
- Steven Gibney
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Jacqueline M Hicks
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Andie Robinson
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Akhil Jain
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Paola Sanjuan-Alberte
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.,Department of Bioengineering and iBB-Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| | - Frankie J Rawson
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| |
Collapse
|
28
|
Baker C, Wagner K, Wagner P, Officer DL, Mawad D. Biofunctional conducting polymers: synthetic advances, challenges, and perspectives towards their use in implantable bioelectronic devices. ADVANCES IN PHYSICS: X 2021. [DOI: 10.1080/23746149.2021.1899850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Affiliation(s)
- Carly Baker
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - Klaudia Wagner
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - Pawel Wagner
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - David L. Officer
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - Damia Mawad
- School of Materials Science and Engineering, UNSW Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
29
|
A conjugated polymer‐liposome complex: A contiguous water‐stable, electronic, and optical interface. VIEW 2020. [DOI: 10.1002/viw.20200081] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
|
30
|
Fang Y, Meng L, Prominski A, Schaumann E, Seebald M, Tian B. Recent advances in bioelectronics chemistry. Chem Soc Rev 2020; 49:7978-8035. [PMID: 32672777 PMCID: PMC7674226 DOI: 10.1039/d0cs00333f] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Research in bioelectronics is highly interdisciplinary, with many new developments being based on techniques from across the physical and life sciences. Advances in our understanding of the fundamental chemistry underlying the materials used in bioelectronic applications have been a crucial component of many recent discoveries. In this review, we highlight ways in which a chemistry-oriented perspective may facilitate novel and deep insights into both the fundamental scientific understanding and the design of materials, which can in turn tune the functionality and biocompatibility of bioelectronic devices. We provide an in-depth examination of several developments in the field, organized by the chemical properties of the materials. We conclude by surveying how some of the latest major topics of chemical research may be further integrated with bioelectronics.
Collapse
Affiliation(s)
- Yin Fang
- The James Franck Institute, University of Chicago, Chicago, IL 60637, USA
| | - Lingyuan Meng
- Pritzker School of Molecular Engineering, University of Chicago, Chicago, IL 60637, USA
| | | | - Erik Schaumann
- Department of Chemistry, University of Chicago, Chicago, IL 60637, USA
| | - Matthew Seebald
- Department of Chemistry, University of Chicago, Chicago, IL 60637, USA
| | - Bozhi Tian
- The James Franck Institute, University of Chicago, Chicago, IL 60637, USA
- Department of Chemistry, University of Chicago, Chicago, IL 60637, USA
- The Institute for Biophysical Dynamics, University of Chicago, Chicago, IL 60637, USA
| |
Collapse
|
31
|
Eslami M, Zeglio E, Alosaimi G, Yan Y, Ruprai H, Macmillan A, Seidel J, Lauto A, Joukhdar H, Rnjak-Kovacina J, Mawad D. A One Step Procedure toward Conductive Suspensions of Liposome-Polyaniline Complexes. Macromol Biosci 2020; 20:e2000103. [PMID: 32537900 DOI: 10.1002/mabi.202000103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 05/21/2020] [Indexed: 11/07/2022]
Abstract
Interaction of conjugated polymers with liposomes is an attractive approach that benefits from both systems' characteristics such as electroactivity and enhanced interaction with cells. Conjugated polymer-liposome complexes have been investigated for bioimaging, drug delivery, and photothermal therapy. Their fabrication has largely been achieved by multistep procedures that require first the synthesis and processing of the conjugated polymer. Here, a new one step fabrication approach is reported based on in situ polymerization of a conjugated monomer precursor around liposomes. Polyaniline (PANI) doped with phytic acid is synthesized via oxidative polymerization in the presence of 1,2-dioleoyl-sn-glycero-3-phosphatidylcholine (DOPC) vesicles to produce a conductive aqueous suspension of Liposome-PANI complexes. PANI interacts with liposomes without disrupting the bilayer as shown using differential scanning calorimetry and fluorescence quenching studies of the hydrophobic Nile red probe. The electronic conductivity of the Liposome-PANI complexes, which stems from the doped PANI accessible on the liposome surface, is confirmed using conductive atomic force microscopy and electrochemical impedance spectroscopy. Further, short-term in vitro cell studies show that the complexes colocalize with the cell membrane without reducing cell proliferation. This study presents a novel fabrication route to conductive suspensions of conjugated polymer-liposome complexes suitable for potential applications at the biointerface.
Collapse
Affiliation(s)
- Minoo Eslami
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Centre for Advanced Macromolecular Design, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Erica Zeglio
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Centre for Advanced Macromolecular Design, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Division of Micro and Nanosystems, KTH Royal Institute of Technology, Stockholm, 10044, Sweden
| | - Ghaida Alosaimi
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- School of Chemistry, Taif University, Taif, 26571, Kingdom of Saudi Arabia
| | - Yihan Yan
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Centre for Advanced Macromolecular Design, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Herleen Ruprai
- School of Science, Western Sydney University, Locked Bag 1797, Penrith, NSW, 2751, Australia
| | - Alexander Macmillan
- Biomedical Imaging Facility, Mark Wainwright Analytical Centre, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Jan Seidel
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Antonio Lauto
- School of Science, Western Sydney University, Locked Bag 1797, Penrith, NSW, 2751, Australia
| | - Habib Joukhdar
- Graduate School of Biomedical Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Jelena Rnjak-Kovacina
- Graduate School of Biomedical Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| | - Damia Mawad
- School of Materials Science and Engineering, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Centre for Advanced Macromolecular Design, UNSW Sydney, Sydney, New South Wales, 2052, Australia
- Australian Centre for Nano Medicine and ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, UNSW Sydney, Sydney, New South Wales, 2052, Australia
| |
Collapse
|
32
|
Geng S, Zhao H, Zhan G, Zhao Y, Yang X. Injectable in Situ Forming Hydrogels of Thermosensitive Polypyrrole Nanoplatforms for Precisely Synergistic Photothermo-Chemotherapy. ACS APPLIED MATERIALS & INTERFACES 2020; 12:7995-8005. [PMID: 32013384 DOI: 10.1021/acsami.9b22654] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The combination of photothermal therapy (PTT) with chemotherapy has great potential to maximize the synergistic effect of thermo-induced chemosensitization and improve treatment performance. To achieve high drug-loading capacity as well as precise synchronization between the controllable release of chemotherapeutics and the duration of near-infrared PTT, in this work, a facile one-step method was first developed to fabricate a novel injectable in situ forming photothermal modulated hydrogel drug delivery platform (D-PPy@PNAs), in which a PNIPAM-based temperature-sensitive acidic triblock polymer [poly(acrylic acid-b-N-isopropylamide-b-acrylic acid (PNA)] was utilized as the stabilizing agent in the polymerization of polypyrrole (PPy). The in situ forming hydrogels showed a sensitive temperature-responsive sol-gel phase-transition behavior, as well as an excellent photothermal property. The strong interaction of ionic bonds together with π-π stacking interactions resulted in high doxorubicin (DOX) loading capacity and controlled/sustained drug release behavior. In addition, D-PPy@PNAs also displayed enhanced cellular uptake and promoted intratumoral penetration of DOX upon NIR laser irradiation. The synergistic photothermal therapy-chemotherapy of D-PPy@PNA hydrogels greatly improved the antitumor efficacy in vivo. Therefore, thermosensitive polypyrrole-based D-PPy@PNA hydrogels may be powerful drug delivery nanoplatforms for precisely synergistic photothermo-chemotherapy of tumors.
Collapse
Affiliation(s)
- Shinan Geng
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology , Huazhong University of Science and Technology , 430074 , Wuhan , China
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica , Huazhong University of Science and Technology , 430074 Wuhan , China
| | - Hao Zhao
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology , Huazhong University of Science and Technology , 430074 , Wuhan , China
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica , Huazhong University of Science and Technology , 430074 Wuhan , China
| | - Guiting Zhan
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology , Huazhong University of Science and Technology , 430074 , Wuhan , China
| | - Yanbing Zhao
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology , Huazhong University of Science and Technology , 430074 , Wuhan , China
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica , Huazhong University of Science and Technology , 430074 Wuhan , China
| | - Xiangliang Yang
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology , Huazhong University of Science and Technology , 430074 , Wuhan , China
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica , Huazhong University of Science and Technology , 430074 Wuhan , China
| |
Collapse
|
33
|
Hai W, Pu S, Wang X, Bao L, Han N, Duan L, Liu J, Goda T, Wu W. Poly(3,4-ethylenedioxythiophene) Bearing Pyridylboronic Acid Group for Specific Recognition of Sialic Acid. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:546-553. [PMID: 31849232 DOI: 10.1021/acs.langmuir.9b03442] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Conducting polymers tethered with molecular recognition elements are good candidates for biosensing applications such as detecting a target molecule with selectivity. We develop a new monomer, namely, 3,4-ethylenedioxythiophene bearing a pyridylboronic acid moiety (EDOT-PyBA), for label-free detection of sialic acid as a cancer biomarker. PyBA, which is known to show specific binding to sialic acid in acid conditions is used as a synthetic ligand instead of lectins. PyBA confirms the enhanced binding affinity for sialic acid at pH 5.0-6.0 compared with traditional phenylboronic acid. Poly(EDOT-PyBA) is electrodeposited on a planar glassy carbon electrode and the obtained film is successfully characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy, water contact angle measurements, and electrochemical impedance spectroscopy. The specific interaction of PyBA with sialic acid at the solution/electrode interface is detected by differential pulse voltammetry in a dynamic range 0.1-3.0 mM with a detection limit of 0.1 mM for a detection time of 3 min. The sensitivity covers the total level of free sialic acid in human serum and the assay time is the shorter than that of other methods. The poly(EDOT-PyBA) electrode successfully detects spiked sialic acid in human serum samples. Owing to its processability, mass productivity, and robustness, polythiophene conjugated with "boronolectin" is a candidate material for developing point-of-care and wearable biosensors.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Tatsuro Goda
- Institute of Biomaterials and Bioengineering , Tokyo Medical and Dental University (TMDU) , 2-3-10 Kanda-Surugadai, Chiyoda , Tokyo 101-0062 , Japan
| | - Wenming Wu
- State Key Laboratory of Applied Optics, Chuangchun Institute of Optics, Fine Mechanics and Physics , Chinese Academy of Sciences , Changchun 130033 , China
| |
Collapse
|
34
|
Hopkins J, Fidanovski K, Lauto A, Mawad D. All-Organic Semiconductors for Electrochemical Biosensors: An Overview of Recent Progress in Material Design. Front Bioeng Biotechnol 2019; 7:237. [PMID: 31608275 PMCID: PMC6773807 DOI: 10.3389/fbioe.2019.00237] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Accepted: 09/11/2019] [Indexed: 12/20/2022] Open
Abstract
Organic semiconductors remain of major interest in the field of bioelectrochemistry for their versatility in chemical and electrochemical behavior. These materials have been tailored using organic synthesis for use in cell stimulation, sustainable energy production, and in biosensors. Recent progress in the field of fully organic semiconductor biosensors is outlined in this review, with a particular emphasis on the synthetic tailoring of these semiconductors for their intended application. Biosensors ultimately function on the basis of a physical, optical or electrochemical change which occurs in the active material when it encounters the target analyte. Electrochemical biosensors are becoming increasingly popular among organic semiconductor biosensors, owing to their good detection performances, and simple operation. The analyte either interacts directly with the semiconductor material in a redox process or undergoes a redox process with a moiety such as an enzyme attached to the semiconductor material. The electrochemical signal is then transduced through the semiconductor material. The most recent examples of organic semiconductor biosensors are discussed here with reference to the material design of polymers with semiconducting backbones, specifically conjugated polymers, and polymer semiconducting dyes. We conclude that direct interaction between the analyte and the semiconducting material is generally more sensitive and cost effective, despite being currently limited by the need to identify, and synthesize selective sensing functionalities. It is also worth noting the potential roles of highly-sensitive, organic transistor devices and small molecule semiconductors, such as the photochromic and redox active molecule spiropyran, as polymer pendant groups in future biosensor designs.
Collapse
Affiliation(s)
- Jonathan Hopkins
- School of Materials Science and Engineering, University of New South Wales Sydney, Sydney, NSW, Australia.,Centre for Advanced Macromolecular Design, University of New South Wales Sydney, Sydney, NSW, Australia
| | - Kristina Fidanovski
- School of Materials Science and Engineering, University of New South Wales Sydney, Sydney, NSW, Australia.,Centre for Advanced Macromolecular Design, University of New South Wales Sydney, Sydney, NSW, Australia
| | - Antonio Lauto
- School of Science, Western Sydney University, Penrith, NSW, Australia
| | - Damia Mawad
- School of Materials Science and Engineering, University of New South Wales Sydney, Sydney, NSW, Australia.,Centre for Advanced Macromolecular Design, University of New South Wales Sydney, Sydney, NSW, Australia.,Australian Centre for NanoMedicine, ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales Sydney, Sydney, NSW, Australia
| |
Collapse
|
35
|
Bai L, Elósegui CG, Li W, Yu P, Fei J, Mao L. Biological Applications of Organic Electrochemical Transistors: Electrochemical Biosensors and Electrophysiology Recording. Front Chem 2019; 7:313. [PMID: 31134185 PMCID: PMC6514146 DOI: 10.3389/fchem.2019.00313] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 04/18/2019] [Indexed: 12/21/2022] Open
Abstract
Organic electrochemical transistors (OECTs) are recently developed high-efficient transducers not only for electrochemical biosensor but also for cell electrophysiological recording due to the separation of gate electrode from the transistor device. The efficient integration of OECTs with electrochemical gate electrode makes the as-prepared sensors with improved performance, such as sensitivity, limit of detection, and selectivity. We herein reviewed the recent progress of OECTs-based biosensors and cell electrophysiology recording, mainly focusing on the principle and chemical design of gate electrode and the channel. First, the configuration, work principle, semiconductor of OECT are briefly introduced. Then different kinds of sensing modes are reviewed, especially for the biosensing and electrophysiological recording. Finally, the challenges and opportunities of this research field are discussed.
Collapse
Affiliation(s)
- Liming Bai
- Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan, China
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
| | - Cristina García Elósegui
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| | - Weiqi Li
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| | - Junjie Fei
- Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan, China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|