1
|
Luo C, Ma X, Zhang Y, Peng Y, Zhou Y, Zhao X, Zhang F. Multiscale Synergistic Gecko-Inspired Adhesive for Stable Adhesion under Varying Preload and Surface Roughness. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:9957-9964. [PMID: 38683042 DOI: 10.1021/acs.langmuir.4c00064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
Inspired by geckos, fibrillar microstructures hold great promise as controllable and reversible adhesives in the engineering field. However, enhancing the adhesion strength and stability of gecko-inspired adhesives (GIAs) under complex real-world contact conditions, such as rough surfaces and varying force fields, is crucial for its commercialization, yet further research is lacking. Here, we propose a hierarchically designed GIA, which features a silicone foam (SF) backing layer and a film-terminated fibrillar microstructure under a subtle multiscale design. This structure has been proven to have a "multiscale synergistic effect", allowing the material to maintain strong and stable adhesion to surfaces with changing normal pressures and roughness. Specifically, under a high load, the adhesive strength is 2 times more than that of conventional GIA, and it is 1.5 times stronger on rough surfaces compared to conventional GIA. Under high pressure and high surface roughness simultaneously, the adhesive strength is 3.3 times higher compared to conventional GIA. Our research demonstrates that the synergistic effect of multiscale biomimetic adhesion structures is highly effective in enhancing the adhesive strength of GIA under some harsh contact conditions.
Collapse
Affiliation(s)
- Chao Luo
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
| | - Xinguo Ma
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu 610066, China
| | - Yaling Zhang
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
| | - Yan Peng
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
| | - Yi Zhou
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
| | - Xiuli Zhao
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
| | - Fengshun Zhang
- Institute of Chemical Materials, Chinese Academy of Engineering Physics, Mianyang 621900, Sichuan, China
| |
Collapse
|
2
|
Rauf S, Bilal RM, Li J, Vaseem M, Ahmad AN, Shamim A. Fully Screen-Printed and Gentle-to-Skin Wet ECG Electrodes with Compact Wireless Readout for Cardiac Diagnosis and Remote Monitoring. ACS NANO 2024; 18:10074-10087. [PMID: 38526458 PMCID: PMC11022287 DOI: 10.1021/acsnano.3c12477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 03/21/2024] [Accepted: 03/21/2024] [Indexed: 03/26/2024]
Abstract
Recent advances in electrocardiogram (ECG) diagnosis and monitoring have triggered a demand for smart and wearable ECG electrodes and readout systems. Here, we report the development of a fully screen-printed gentle-to-skin wet ECG electrode integrated with a scaled-down printed circuit board (PCB) packaged inside a 3D-printed antenna-on-package (AoP). All three components of the wet ECG electrode (i.e., silver nanowire-based conductive part, electrode gel, and adhesive gel) are screen-printed on a flexible plastic substrate and only require 265 times less metal for the conductive part and 176 times less ECG electrode gel than the standard commercial wet ECG electrodes. In addition, our electrically small AoP achieved a maximum read range of 142 m and offers a 4 times larger wireless communication range than the typical commercial chip antenna. The adult volunteers' study results indicated that our system recorded ECG data that correlated well with data from a commercial ECG system and electrodes. Furthermore, in the context of a 12-lead ECG diagnostic system, the fully printed wet ECG electrodes demonstrated a performance similar to that of commercially available wet ECG electrodes while being gentle on the skin. This was confirmed through a blind review method by two cardiology consultants and one family medicine consultant, validating the consistency of the diagnostic information obtained from both electrodes. In conclusion, these findings highlight the potential of fully screen-printed wet ECG electrodes for both monitoring and diagnostic purposes. These electrodes could serve as potential candidates for clinical practice, and the screen-printing method has the capability to facilitate industrial mass production.
Collapse
Affiliation(s)
- Sakandar Rauf
- Electrical
and Computer Engineering, CEMSE, King Abdullah
University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Rana M. Bilal
- Electrical
and Computer Engineering, CEMSE, King Abdullah
University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Jiajun Li
- Electrical
and Computer Engineering, CEMSE, King Abdullah
University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Mohammad Vaseem
- Electrical
and Computer Engineering, CEMSE, King Abdullah
University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Adeel N. Ahmad
- School
of Medicine, University of Nottingham, Nottingham NG7 2UH, United Kingdom
| | - Atif Shamim
- Electrical
and Computer Engineering, CEMSE, King Abdullah
University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| |
Collapse
|
3
|
Kwon Y, Lee S, Kim J, Jun J, Jeon W, Park Y, Kim HJ, Gierschner J, Lee J, Kim Y, Kwon MS. Ultraviolet light blocking optically clear adhesives for foldable displays via highly efficient visible-light curing. Nat Commun 2024; 15:2829. [PMID: 38565557 PMCID: PMC10987679 DOI: 10.1038/s41467-024-47104-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 03/18/2024] [Indexed: 04/04/2024] Open
Abstract
In developing an organic light-emitting diode (OLED) panel for a foldable smartphone (specifically, a color filter on encapsulation) aimed at reducing power consumption, the use of a new optically clear adhesive (OCA) that blocks UV light was crucial. However, the incorporation of a UV-blocking agent within the OCA presented a challenge, as it restricted the traditional UV-curing methods commonly used in the manufacturing process. Although a visible-light curing technique for producing UV-blocking OCA was proposed, its slow curing speed posed a barrier to commercialization. Our study introduces a highly efficient photo-initiating system (PIS) for the rapid production of UV-blocking OCAs utilizing visible light. We have carefully selected the photocatalyst (PC) to minimize electron and energy transfer to UV-blocking agents and have chosen co-initiators that allow for faster electron transfer and more rapid PC regeneration compared to previously established amine-based co-initiators. This advancement enabled a tenfold increase in the production speed of UV-blocking OCAs, while maintaining their essential protective, transparent, and flexible properties. When applied to OLED devices, this OCA demonstrated UV protection, suggesting its potential for broader application in the safeguarding of various smart devices.
Collapse
Affiliation(s)
- Yonghwan Kwon
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Seokju Lee
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Junkyu Kim
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Jinwon Jun
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea
| | - Woojin Jeon
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Youngjoo Park
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Hyun-Joong Kim
- Department of Agriculture, Forestry and Bioresources, Seoul National University, Seoul, Republic of Korea
| | - Johannes Gierschner
- Madrid Institute for Advanced Studies, IMDEA Nanoscience, Calle Faraday 9, Campus Cantoblanco, 28049, Madrid, Spain
| | - Jaesang Lee
- Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea.
| | - Youngdo Kim
- Samsung Display Co., Ltd., Cheonan, Republic of Korea.
| | - Min Sang Kwon
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea.
| |
Collapse
|
4
|
Pan D, Hu J, Wang B, Xia X, Cheng Y, Wang C, Lu Y. Biomimetic Wearable Sensors: Emerging Combination of Intelligence and Electronics. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2303264. [PMID: 38044298 PMCID: PMC10837381 DOI: 10.1002/advs.202303264] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 10/03/2023] [Indexed: 12/05/2023]
Abstract
Owing to the advancement of interdisciplinary concepts, for example, wearable electronics, bioelectronics, and intelligent sensing, during the microelectronics industrial revolution, nowadays, extensively mature wearable sensing devices have become new favorites in the noninvasive human healthcare industry. The combination of wearable sensing devices with bionics is driving frontier developments in various fields, such as personalized medical monitoring and flexible electronics, due to the superior biocompatibilities and diverse sensing mechanisms. It is noticed that the integration of desired functions into wearable device materials can be realized by grafting biomimetic intelligence. Therefore, herein, the mechanism by which biomimetic materials satisfy and further enhance system functionality is reviewed. Next, wearable artificial sensory systems that integrate biomimetic sensing into portable sensing devices are introduced, which have received significant attention from the industry owing to their novel sensing approaches and portabilities. To address the limitations encountered by important signal and data units in biomimetic wearable sensing systems, two paths forward are identified and current challenges and opportunities are presented in this field. In summary, this review provides a further comprehensive understanding of the development of biomimetic wearable sensing devices from both breadth and depth perspectives, offering valuable guidance for future research and application expansion of these devices.
Collapse
Affiliation(s)
- Donglei Pan
- College of Light Industry and Food EngineeringGuangxi UniversityNanningGuangxi530004China
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Jiawang Hu
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Bin Wang
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Xuanjie Xia
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Yifan Cheng
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Cheng‐Hua Wang
- College of Light Industry and Food EngineeringGuangxi UniversityNanningGuangxi530004China
| | - Yuan Lu
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| |
Collapse
|
5
|
Iqbal H, Fernandes Q, Idoudi S, Basineni R, Billa N. Status of Polymer Fused Deposition Modeling (FDM)-Based Three-Dimensional Printing (3DP) in the Pharmaceutical Industry. Polymers (Basel) 2024; 16:386. [PMID: 38337275 DOI: 10.3390/polym16030386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 01/22/2024] [Accepted: 01/29/2024] [Indexed: 02/12/2024] Open
Abstract
Additive manufacturing (AM) or 3D printing (3DP) is arguably a versatile and more efficient way for the production of solid dosage forms such as tablets. Of the various 3DP technologies currently available, fused deposition modeling (FDM) includes unique characteristics that offer a range of options in the production of various types of tablets. For example, amorphous solid dispersions (ASDs), enteric-coated tablets or poly pills can be produced using an appropriate drug/polymer combination during FDM 3DP. The technology offers the possibility of evolving personalized medicines into cost-effective production schemes at pharmacies and hospital dispensaries. In this review, we highlight key FDM features that may be exploited for the production of tablets and improvement of therapy, with emphasis on gastrointestinal delivery. We also highlight current constraints that must be surmounted to visualize the deployment of this technology in the pharmaceutical and healthcare industries.
Collapse
Affiliation(s)
- Heba Iqbal
- Pharmaceutical Sciences Department, College of Pharmacy, QU Health, Qatar University, Doha P.O. Box 2713, Qatar
| | - Queenie Fernandes
- College of Medicine, QU Health, Qatar University, Doha P.O. Box 2713, Qatar
| | - Sourour Idoudi
- Pharmaceutical Sciences Department, College of Pharmacy, QU Health, Qatar University, Doha P.O. Box 2713, Qatar
| | - Renuka Basineni
- Pharmaceutical Sciences Department, College of Pharmacy, QU Health, Qatar University, Doha P.O. Box 2713, Qatar
| | - Nashiru Billa
- Pharmaceutical Sciences Department, College of Pharmacy, QU Health, Qatar University, Doha P.O. Box 2713, Qatar
| |
Collapse
|
6
|
Morris G, Goodman S, Sorzabal Bellido I, Milanese C, Girella A, Pallavicini P, Taglietti A, Gaboardi M, Jäckel F, Diaz Fernandez YA, Raval R. Temperature and pH Stimuli-Responsive System Delivers Location-Specific Antimicrobial Activity with Natural Products. ACS APPLIED BIO MATERIALS 2024; 7:131-143. [PMID: 38079569 DOI: 10.1021/acsabm.3c00588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
Abstract
Smart materials with controlled stimuli-responsive functions are at the forefront of technological development. In this work, we present a generic strategy that combines simple components, physicochemical responses, and easy fabrication methods to achieve a dual stimuli-responsive system capable of location-specific antimicrobial cargo delivery. The encapsulated system is fabricated by combining a biocompatible inert polymeric matrix of poly(dimethylsiloxane) (PDMS) and a bioactive cargo of saturated fatty acids. We demonstrate the effectiveness of our approach to deliver antimicrobial activity for the model bacteria Escherichia coli. The system responds to two control variables, temperature and pH, delivering two levels of antimicrobial response under distinct combinations of stimuli: one response toward the planktonic media and another response directly at the surface for sessile bacteria. Spatially resolved Raman spectroscopy alongside thermal and structural material analysis reveals that the system not only exhibits ON/OFF states but can also control relocation and targeting of the active cargo toward either the surface or the liquid media, leading to different ON/OFF states for the planktonic and sessile bacteria. The approach proposed herein is technologically simple and scalable, facing low regulatory barriers within the food and healthcare sectors by using approved components and relying on fundamental chemical processes. Our results also provide a proof-of-concept platform for the design and easy fabrication of delivery systems capable of operating as Boolean logic gates, delivering different responses under different environmental conditions.
Collapse
Affiliation(s)
- Gareth Morris
- Open Innovation Hub for Antimicrobial Surfaces, Surface Science Research Centre, University of Liverpool, Liverpool L69 3BX, U.K
- Department of Physics and Stephenson Institute for Renewable Energy, University of Liverpool, Liverpool L69 7ZE, U.K
| | - Sean Goodman
- Open Innovation Hub for Antimicrobial Surfaces, Surface Science Research Centre, University of Liverpool, Liverpool L69 3BX, U.K
| | - Ioritz Sorzabal Bellido
- Open Innovation Hub for Antimicrobial Surfaces, Surface Science Research Centre, University of Liverpool, Liverpool L69 3BX, U.K
| | - Chiara Milanese
- Department of Chemistry, University of Pavia, Via Taramelli 12, Pavia 27100, Italy
| | - Alessandro Girella
- Department of Chemistry, University of Pavia, Via Taramelli 12, Pavia 27100, Italy
| | | | - Angelo Taglietti
- Department of Chemistry, University of Pavia, Via Taramelli 12, Pavia 27100, Italy
| | - Mattia Gaboardi
- Materials Physics Center, CSIC-UPV/EHU, Donostia - San Sebastian 20018, Spain
| | - Frank Jäckel
- Department of Physics and Stephenson Institute for Renewable Energy, University of Liverpool, Liverpool L69 7ZE, U.K
| | - Yuri A Diaz Fernandez
- Open Innovation Hub for Antimicrobial Surfaces, Surface Science Research Centre, University of Liverpool, Liverpool L69 3BX, U.K
- Department of Chemistry, University of Pavia, Via Taramelli 12, Pavia 27100, Italy
| | - Rasmita Raval
- Open Innovation Hub for Antimicrobial Surfaces, Surface Science Research Centre, University of Liverpool, Liverpool L69 3BX, U.K
| |
Collapse
|
7
|
Hassani HTM, Baji A. Recent Progress on the Use of Stimulus-Responsive Materials for Dry Adhesive Applications. ACS APPLIED BIO MATERIALS 2023; 6:4002-4019. [PMID: 37795994 DOI: 10.1021/acsabm.3c00504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
Stimulus-responsive dry adhesives, inspired by the adhesive mechanisms displayed by the fibrillar structures present on the feet of geckos, have emerged as a promising area of research for applications such as robotic grippers and climbing robots. These stimulus-responsive dry adhesives exhibit some unique capabilities, as their ability to adhere to and detach from surfaces can be controlled with the help of an external stimulus. For example, studies have developed magnetic field-responsive dry adhesives and show that the adhesion of these materials can be turned on and off by controlling the applied magnetic field. Light-responsive adhesives have also been developed and shown to reverse their adhesion using infrared light as the stimulus. Such materials show tremendous promise in pick-and-place systems for handling delicate objects and microelectronic products. The focus of this article is to review the stimulus-responsive materials that have been used to develop dry adhesives. The mechanisms adopted by these stimulus-responsive materials to switch their adhesion are discussed. Applications of stimulus-responsive dry adhesives are presented, and last, the future perspective of these materials is discussed.
Collapse
Affiliation(s)
- Hasan Talal M Hassani
- Department of Engineering, School of Computing, Engineering and Mathematical Sciences (SCEMS), La Trobe University Bundoora, 3086 Victoria, Australia
- Jeddah Academy for Maritime Science and Security Studies Al-Ruwais 2639-7533, Jeddah 22231, Saudi Arabia
| | - Avinash Baji
- Department of Engineering, School of Computing, Engineering and Mathematical Sciences (SCEMS), La Trobe University Bundoora, 3086 Victoria, Australia
| |
Collapse
|
8
|
Back JH, Kwon Y, Cho H, Lee H, Ahn D, Kim HJ, Yu Y, Kim Y, Lee W, Kwon MS. Visible-Light-Curable Acrylic Resins toward UV-Light-Blocking Adhesives for Foldable Displays. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2204776. [PMID: 35901501 DOI: 10.1002/adma.202204776] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 07/08/2022] [Indexed: 06/15/2023]
Abstract
Current technological advances in the organic light-emitting diode panel design of foldable smartphones demand advanced adhesives with UV-blocking abilities, beyond their conventional roles of bonding objects and relieving deformation stress. However, optically clear adhesives (OCAs) with UV-blocking ability cannot be prepared using conventional UV-curing methods relying on a photoinitiator. Herein, a new acrylic resin that can be efficiently cured using visible light without oxygen removal is presented, which may be used to develop UV-blocking OCAs for use in current flexible displays. A novel photocatalyst and a specific combination of additives facilitate sufficiently rapid curing under visible light in the presence of UV-absorbers. Only a very small amount of the highly active photocatalyst is required to prepare UV-blocking OCA films with very high transparency in the visible region. Using this system, a UV-blocking OCA that nearly meets the specifications of an OCA used in commercialized foldable smartphones is realized. This technology can also be utilized in other applications that require highly efficient visible light curing, such as optically clear resins, dental resins, and 3D/4D-printable materials.
Collapse
Affiliation(s)
- Jong-Ho Back
- Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology (KRICT), Ulsan, 44412, Republic of Korea
- Department of Agriculture, Forestry and Bioresources, Seoul National University, Seoul, 08826, Republic of Korea
| | - Yonghwan Kwon
- Department of Materials Science and Engineering, Seoul National University, Seoul, 08826, Republic of Korea
- Department of Materials Science and Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea
| | - Hyeju Cho
- Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology (KRICT), Ulsan, 44412, Republic of Korea
| | - Huesoo Lee
- Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology (KRICT), Ulsan, 44412, Republic of Korea
| | - Dowon Ahn
- Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology (KRICT), Ulsan, 44412, Republic of Korea
| | - Hyun-Joong Kim
- Department of Agriculture, Forestry and Bioresources, Seoul National University, Seoul, 08826, Republic of Korea
| | - Youngchang Yu
- Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology (KRICT), Ulsan, 44412, Republic of Korea
| | - Youngdo Kim
- Samsung Display Co., Ltd., Cheonan, 31086, Republic of Korea
| | - Wonjoo Lee
- Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology (KRICT), Ulsan, 44412, Republic of Korea
| | - Min Sang Kwon
- Department of Materials Science and Engineering, Seoul National University, Seoul, 08826, Republic of Korea
| |
Collapse
|
9
|
Lee H, Jang J, Lee J, Shin M, Lee JS, Son D. Stretchable Gold Nanomembrane Electrode with Ionic Hydrogel Skin-Adhesive Properties. Polymers (Basel) 2023; 15:3852. [PMID: 37765706 PMCID: PMC10537659 DOI: 10.3390/polym15183852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 09/16/2023] [Accepted: 09/20/2023] [Indexed: 09/29/2023] Open
Abstract
Skin has a dynamic surface and offers essential information through biological signals originating from internal organs, blood vessels, and muscles. Soft and stretchable bioelectronics can be used in wearable machines for long-term stability and to continuously obtain distinct bio-signals in conjunction with repeated expansion and contraction with physical activities. While monitoring bio-signals, the electrode and skin must be firmly attached for high signal quality. Furthermore, the signal-to-noise ratio (SNR) should be high enough, and accordingly, the ionic conductivity of an adhesive hydrogel needs to be improved. Here, we used a chitosan-alginate-chitosan (CAC) triple hydrogel layer as an interface between the electrodes and the skin to enhance ionic conductivity and skin adhesiveness and to minimize the mechanical mismatch. For development, thermoplastic elastomer Styrene-Ethylene-Butylene-Styrene (SEBS) dissolved in toluene was used as a substrate, and gold nanomembranes were thermally evaporated on SEBS. Subsequently, CAC triple layers were drop-casted onto the gold surface one by one and dried successively. Lastly, to demonstrate the performance of our electrodes, a human electrocardiogram signal was monitored. The electrodes coupled with our CAC triple hydrogel layer showed high SNR with clear PQRST peaks.
Collapse
Affiliation(s)
- Hyelim Lee
- School of Electronic and Electrical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Jaepyo Jang
- Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, Republic of Korea (M.S.)
| | - Jaebeom Lee
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, Republic of Korea (M.S.)
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Mikyung Shin
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, Republic of Korea (M.S.)
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon 16419, Republic of Korea
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Jung Seung Lee
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon 16419, Republic of Korea
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Donghee Son
- Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, Republic of Korea (M.S.)
- Department of Superintelligence Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| |
Collapse
|
10
|
Gao K, Wu N, Ji B, Liu J. A Film Electrode upon Nanoarchitectonics of Bacterial Cellulose and Conductive Fabric for Forehead Electroencephalogram Measurement. SENSORS (BASEL, SWITZERLAND) 2023; 23:7887. [PMID: 37765945 PMCID: PMC10535237 DOI: 10.3390/s23187887] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/08/2023] [Accepted: 09/11/2023] [Indexed: 09/29/2023]
Abstract
In this paper, we present a soft and moisturizing film electrode based on bacterial cellulose and Ag/AgCl conductive cloth as a potential replacement for gel electrode patches in electroencephalogram (EEG) recording. The electrode materials are entirely flexible, and the bacterial cellulose membrane facilitates convenient adherence to the skin. EEG signals are transmitted from the skin to the bacterial cellulose first and then transferred to the Ag/AgCl conductive cloth connected to the amplifier. The water in the bacterial cellulose moisturizes the skin continuously, reducing the contact impedance to less than 10 kΩ, which is lower than commercial gel electrode patches. The contact impedance and equivalent circuits indicate that the bacterial cellulose electrode effectively reduces skin impedance. Moreover, the bacterial cellulose electrode exhibits lower noise than the gel electrode patch. The bacterial cellulose electrode has demonstrated success in collecting α rhythms. When recording EEG signals, the bacterial cellulose electrode and gel electrode have an average coherence of 0.86, indicating that they have similar performance across different EEG bands. Compared with current mainstream conductive rubber dry electrodes, gel electrodes, and conductive cloth electrodes, the bacterial cellulose electrode has obvious advantages in terms of contact impedance. The bacterial cellulose electrode does not cause skin discomfort after long-term recording, making it more suitable for applications with strict requirements for skin affinity than gel electrode patches.
Collapse
Affiliation(s)
- Kunpeng Gao
- The School of Information Science and Technology, Donghua University, Shanghai 200051, China;
| | - Nailong Wu
- The School of Information Science and Technology, Donghua University, Shanghai 200051, China;
| | - Bowen Ji
- The Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an 710072, China;
| | - Jingquan Liu
- Department of Micro/Nano-Electronics, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
11
|
Seok M, Choi Y, Cho YH. Reusable and Porous Skin Patches with Thermopneumatic Adhesion Control Capability and High Water Vapor Permeability. ACS APPLIED MATERIALS & INTERFACES 2023; 15:42395-42403. [PMID: 37655485 DOI: 10.1021/acsami.3c10603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
We present a reusable and porous skin patch (RPS patch) capable of controlling adhesion force with a thermal-pneumatic method for repetitive use as well as improving moisture permeability for long-term use without skin troubles. Previous skin patches cause skin troubles due to high adhesion force (∼30 kPa) and low moisture permeability (∼382 g/m2/day), hindering them from repeatable and long-term use. We control the skin adhesion force of the RPS patch using thermopneumatic pressure generated by an embedded heater on multiple chamber arrays. The RPS patch controls the adhesion force ranging from 8 to 29 kPa on both dry and wet skin while keeping the stable adhesion force for 48 h. It shows repeatable adhesion up to 100 times, and the adhesion force is restored after the RPS patch is washed with water, thus enabling repetitive skin adhesion. We improve the moisture permeability of the RPS patch to 733 g/m2/day while maintaining the adhesion force by making the RPS patch with porous materials. The RPS patch shows no skin troubles for 7 days of attachment, thereby being available for long-term skin attachment. The RPS patch, having adhesion control capability and high moisture permeability, shows potential for use in daily life in biomedical applications, including wearable sensors, medical adhesives, and rehabilitation robots.
Collapse
Affiliation(s)
- Minho Seok
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Yebin Choi
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Young-Ho Cho
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| |
Collapse
|
12
|
Luo R, Shi B, Luo D, Li Z. Self-powered electrical stimulation assisted skin wound therapy. Sci Bull (Beijing) 2023; 68:1740-1743. [PMID: 37474443 DOI: 10.1016/j.scib.2023.07.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Affiliation(s)
- Ruizeng Luo
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China; School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bojing Shi
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China; School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| | - Dan Luo
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China; School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Zhou Li
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China; School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, China.
| |
Collapse
|
13
|
Hwang D, Lee C, Yang X, Pérez-González JM, Finnegan J, Lee B, Markvicka EJ, Long R, Bartlett MD. Metamaterial adhesives for programmable adhesion through reverse crack propagation. NATURE MATERIALS 2023; 22:1030-1038. [PMID: 37349397 DOI: 10.1038/s41563-023-01577-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 05/04/2023] [Indexed: 06/24/2023]
Abstract
Adhesives are typically either strong and permanent or reversible with limited strength. However, current strategies to create strong yet reversible adhesives needed for wearable devices, robotics and material disassembly lack independent control of strength and release, require complex fabrication or only work in specific conditions. Here we report metamaterial adhesives that simultaneously achieve strong and releasable adhesion with spatially selectable adhesion strength through programmed cut architectures. Nonlinear cuts uniquely suppress crack propagation by forcing cracks to propagate backwards for 60× enhancement in adhesion, while allowing crack growth in the opposite direction for easy release and reusability. This mechanism functions in numerous adhesives on diverse substrates in wet and dry conditions and enables highly tunable adhesion with independently programmable adhesion strength in two directions simultaneously at any location. We create these multifunctional materials in a maskless, digital fabrication framework to rapidly customize adhesive characteristics with deterministic control for next-generation adhesives.
Collapse
Affiliation(s)
- Dohgyu Hwang
- Department of Mechanical Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, VA, USA
- Macromolecules Innovation Institute, Virginia Tech, Blacksburg, VA, USA
| | - Chanhong Lee
- Department of Mechanical Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, VA, USA
| | - Xingwei Yang
- Department of Mechanical Engineering, University of Colorado, Boulder, CO, USA
| | | | - Jason Finnegan
- Department of Mechanical & Materials Engineering, Smart Materials and Robotics Lab, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - Bernard Lee
- Department of Mechanical & Materials Engineering, Smart Materials and Robotics Lab, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - Eric J Markvicka
- Department of Mechanical & Materials Engineering, Smart Materials and Robotics Lab, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - Rong Long
- Department of Mechanical Engineering, University of Colorado, Boulder, CO, USA
| | - Michael D Bartlett
- Department of Mechanical Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, VA, USA.
- Macromolecules Innovation Institute, Virginia Tech, Blacksburg, VA, USA.
| |
Collapse
|
14
|
Akaike K, Shimoi Y, Miura T, Morita H, Akiyama H, Horiuchi S. Disentangling Origins of Adhesive Bonding at Interfaces between Epoxy/Amine Adhesive and Aluminum. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023. [PMID: 37467444 DOI: 10.1021/acs.langmuir.3c01218] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Joining metals by adhesive bonding is essential in widespread fields such as mobility, dentistry, and electronics. Although adhesive technology has grown since the 1920s, the roles of interfacial phenomena in adhesive bonding are still elusive, which hampers the on-demand selection of surface treatment and adhesive types. In the present study, we clarified how chemical interactions and mechanical interlocking governed adhesive bonding by evaluating adhesion properties at the interfaces between epoxy/amine adhesive and two kinds of Al adherends: a flat aluminum hydroxide (AlxOyHz) and technical Al plate with roughness. Spectroscopic and microscopical data demonstrate that the protonation of the amino groups in an amine hardener converts Al(OH)3 on the AlxOyHz surface to AlO(OH). The interfacial protonation results in an interfacial dipole layer with positive charges on the adhesive side, whose electrostatic interaction increases the interfacial fracture energy. The double cantilever beam tests for the flat AlxOyHz and technical Al substrates clarify that the mechanical interlocking originating from the surface roughness further increases the fracture energy. This study disentangles the roles of the chemical interactions and mechanical interlocking occurring at the epoxy adhesive/Al interface in the adhesion mechanism.
Collapse
Affiliation(s)
- Kouki Akaike
- Nanomaterials Research Institute, National Institute of Advanced Industrial Science and Technology, Central 5, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| | - Yukihiro Shimoi
- Research Center for Computational Design of Advanced Functional Materials (CD-FMat), National Institute of Advanced Industrial Science and Technology, Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
| | - Toshiaki Miura
- Research Center for Computational Design of Advanced Functional Materials (CD-FMat), National Institute of Advanced Industrial Science and Technology, Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
| | - Hiroshi Morita
- Research Center for Computational Design of Advanced Functional Materials (CD-FMat), National Institute of Advanced Industrial Science and Technology, Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
| | - Haruhisa Akiyama
- Nanomaterials Research Institute, National Institute of Advanced Industrial Science and Technology, Central 5, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| | - Shin Horiuchi
- Nanomaterials Research Institute, National Institute of Advanced Industrial Science and Technology, Central 5, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| |
Collapse
|
15
|
Fitzgerald DM, Colson YL, Grinstaff MW. Synthetic Pressure Sensitive Adhesives for Biomedical Applications. Prog Polym Sci 2023; 142:101692. [PMID: 37273788 PMCID: PMC10237363 DOI: 10.1016/j.progpolymsci.2023.101692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Pressure sensitive adhesives are components of everyday products found in homes, offices, industries, and hospitals. Serving the general purpose of fissure repair and object fixation, pressure sensitive adhesives indiscriminately bind surfaces, as long as contact pressure is administered at application. With that being said, the chemical and material properties of the adhesive formulation define the strength of a pressure sensitive adhesive to a particular surface. Given our increased understanding of the viscoelastic material requirements as well as the intermolecular interactions at the binding interface required for functional adhesives, pressure sensitive adhesives are now being explored for greater use. New polymer formulations impart functionality and degradability for both internal and external applications. This review highlights the structure-property relationships between polymer architecture and pressure sensitive adhesion, specifically for medicine. We discuss the rational, molecular-level design of synthetic polymers for durable, removable, and biocompatible adhesion to wet surfaces like tissue. Finally, we examine prevalent challenges in biomedical wound closure and the new, innovative strategies being employed to address them. We conclude by summarizing the progress of current research, identifying additional clinical opportunities, and discussing future prospects.
Collapse
Affiliation(s)
- Danielle M. Fitzgerald
- Department of Chemistry, Biomedical Engineering, and Medicine, Boston University, Boston, MA 02115
| | - Yolonda L. Colson
- Division of Thoracic Surgery, Department of Surgery, Massachusetts General Hospital, Boston, MA 02214
| | - Mark W. Grinstaff
- Department of Chemistry, Biomedical Engineering, and Medicine, Boston University, Boston, MA 02115
| |
Collapse
|
16
|
Zou J, Chen Z, Wang SJ, Liu ZH, Liu YJ, Feng PY, Jing X. A Flexible Sensor with Excellent Environmental Stability Using Well-Designed Encapsulation Structure. Polymers (Basel) 2023; 15:polym15102308. [PMID: 37242884 DOI: 10.3390/polym15102308] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/06/2023] [Accepted: 05/12/2023] [Indexed: 05/28/2023] Open
Abstract
The hydrogel-based sensors suffer from poor stability and low sensitivity, severely limiting their further development. It is still "a black box" to understand the effect of the encapsulation as well as the electrode on the performance of the hydrogel-based sensors. To address these problems, we prepared an adhesive hydrogel that could robustly adhere to Ecoflex (adhesive strength is 4.7 kPa) as an encapsulation layer and proposed a rational encapsulation model that fully encapsulated the hydrogel within Ecoflex. Owing to the excellent barrier and resilience of Ecoflex, the encapsulated hydrogel-based sensor can still work normally after 30 days, displaying excellent long-term stability. In addition, we performed theoretical and simulation analyses on the contact state between the hydrogel and the electrode. It was surprising to find that the contact state significantly affects the sensitivity of the hydrogel sensors (the maximum difference in sensitivity was 333.6%), indicating that the reasonable design of the encapsulation and electrode are indispensable parts for fabricating successful hydrogel sensors. Therefore, we paved the way for a novel insight to optimize the properties of the hydrogel sensors, which is greatly favorable to developing hydrogel-based sensors to be applied in various fields.
Collapse
Affiliation(s)
- Jian Zou
- Key Laboratory of Advanced Packaging Materials and Technology of Hunan Province, Hunan University of Technology, Zhuzhou 412007, China
- National and Local Joint Engineering Research Center for Advanced Packaging Material and Technology, Hunan University of Technology, Zhuzhou 412007, China
| | - Zhuo Chen
- Key Laboratory of Advanced Packaging Materials and Technology of Hunan Province, Hunan University of Technology, Zhuzhou 412007, China
- National and Local Joint Engineering Research Center for Advanced Packaging Material and Technology, Hunan University of Technology, Zhuzhou 412007, China
| | - Sheng-Ji Wang
- Key Laboratory of Advanced Packaging Materials and Technology of Hunan Province, Hunan University of Technology, Zhuzhou 412007, China
- National and Local Joint Engineering Research Center for Advanced Packaging Material and Technology, Hunan University of Technology, Zhuzhou 412007, China
| | - Zi-Hao Liu
- Key Laboratory of Advanced Packaging Materials and Technology of Hunan Province, Hunan University of Technology, Zhuzhou 412007, China
| | - Yue-Jun Liu
- Key Laboratory of Advanced Packaging Materials and Technology of Hunan Province, Hunan University of Technology, Zhuzhou 412007, China
- National and Local Joint Engineering Research Center for Advanced Packaging Material and Technology, Hunan University of Technology, Zhuzhou 412007, China
| | - Pei-Yong Feng
- National and Local Joint Engineering Research Center for Advanced Packaging Material and Technology, Hunan University of Technology, Zhuzhou 412007, China
| | - Xin Jing
- Key Laboratory of Advanced Packaging Materials and Technology of Hunan Province, Hunan University of Technology, Zhuzhou 412007, China
- National and Local Joint Engineering Research Center for Advanced Packaging Material and Technology, Hunan University of Technology, Zhuzhou 412007, China
| |
Collapse
|
17
|
Jiao S, Zhang X, Cai H, Wu S, Ou X, Han G, Zhao J, Li Y, Guo W, Liu T, Qu W. Recent advances in biomimetic hemostatic materials. Mater Today Bio 2023; 19:100592. [PMID: 36936399 PMCID: PMC10020683 DOI: 10.1016/j.mtbio.2023.100592] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 02/26/2023] Open
Abstract
Although the past decade has witnessed unprecedented medical advances, achieving rapid and effective hemostasis remains challenging. Uncontrolled bleeding and wound infections continue to plague healthcare providers, increasing the risk of death. Various types of hemostatic materials are nowadays used during clinical practice but have many limitations, including poor biocompatibility, toxicity and biodegradability. Recently, there has been a burgeoning interest in organisms that stick to objects or produce sticky substances. Indeed, applying biological adhesion properties to hemostatic materials remains an interesting approach. This paper reviews the biological behavior, bionics, and mechanisms related to hemostasis. Furthermore, this paper covers the benefits, challenges and prospects of biomimetic hemostatic materials.
Collapse
Affiliation(s)
- Simin Jiao
- Department of Gastrointestinal Nutrition and Hernia Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
| | - Xi Zhang
- Department of Burn Surgery, The First Hospital of Jilin University, 71 Xinmin Street, Changchun, 130021, PR China
| | - Hang Cai
- Department of Pharmacy, The Second Hospital of Jilin University, Changchun, 130041, PR China
| | - Siyu Wu
- Department of Hand Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
| | - Xiaolan Ou
- Department of Hand Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
| | - Guangda Han
- Department of Gastrointestinal Nutrition and Hernia Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
| | - Jie Zhao
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, 130022, PR China
| | - Yan Li
- Trauma and Reparative Medicine, Karolinska University Hospital, Stockholm, Sweden
- The Division of Orthopedics and Biotechnology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden
| | - Wenlai Guo
- Department of Hand Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
- Corresponding author.
| | - Tianzhou Liu
- Department of Gastrointestinal Nutrition and Hernia Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
- Corresponding author.
| | - Wenrui Qu
- Department of Hand Surgery, The Second Hospital of Jilin University, 218 Ziqiang Street, Changchun, 130041, PR China
- Corresponding author.
| |
Collapse
|
18
|
Duan W, Yu Z, Cui W, Zhang Z, Zhang W, Tian Y. Bio-inspired switchable soft adhesion for the boost of adhesive surfaces and robotics applications: A brief review. Adv Colloid Interface Sci 2023; 313:102862. [PMID: 36848868 DOI: 10.1016/j.cis.2023.102862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 02/10/2023] [Accepted: 02/17/2023] [Indexed: 02/22/2023]
Abstract
In nature, millions of creatures, such as geckos, tree frogs, octopuses, etc., have evolved fantastic switchable adhesion capabilities to climb swiftly on vertical even inverted surfaces or hunt for prey easily, adapting to harsh and unpredictable environments. Notably, these fascinating adhesive behaviors depend on interfacial forces (friction, van der Waals force, capillary force, vacuum suction, etc.), which primarily originate from the interactions between the soft micro/nanostructures evolved in the natural creatures and objects. Over the past few decades, these biological switchable adhesives have inspired scientists to explore and engineer desirable artificial adhesives. In this review, we summarized the state-of-the-art research on the ultra-fast adhesive motion of three types of biological organisms (gecko, tree frog, and octopus). Firstly, the basic adhesion principles in the three representative organisms, including micro/nanostructures, interfacial forces, and fundamental adhesion models, are reviewed. Then, we discussed the adhesion mechanisms of the prominent organisms from the perspective of soft contacts between micro/nanostructures and the substrates. Later, the mechanics-guided design principles of artificial adhesive surfaces, as well as the smart adhesion strategies, are summarized. The applications of these bio-inspired switchable adhesives are demonstrated, including wearable electronic devices, soft grippers, and climbing robots. The challenges and opportunities in this fast-growing field are also discussed.
Collapse
Affiliation(s)
- Weiwang Duan
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Zhilin Yu
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Wenhui Cui
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Zengxin Zhang
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Wenling Zhang
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
| | - Yu Tian
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
19
|
Core-shell dry adhesives for rough surfaces via electrically responsive self-growing strategy. Nat Commun 2022; 13:7659. [PMID: 36496484 PMCID: PMC9741600 DOI: 10.1038/s41467-022-35436-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 12/02/2022] [Indexed: 12/13/2022] Open
Abstract
Bioinspired dry adhesives have an extraordinary impact in the field of robotic manipulation and locomotion. However, there is a considerable difference between artificial structures and biological ones regarding surface adaptability, especially for rough surfaces. This can be attributed to their distinct structural configuration and forming mechanism. Here, we propose a core-shell adhesive structure that is obtained through a growth strategy, i.e., an electrically responsive self-growing core-shell structure. This growth strategy results in a specific mushroom-shaped structure with a rigid core and a soft shell, which exhibits excellent adhesion on typical target surfaces with roughness ranging from the nanoscale to the microscale up to dozens of micrometers. The proposed adhesion strategy extends dry adhesives from smooth surfaces to rough ones, especially for rough surfaces with roughness up to dozens or hundreds of micrometers, opening an avenue for the development of dry adhesive-based devices and systems.
Collapse
|
20
|
Triboelectric nanogenerators for clinical diagnosis and therapy: A report of recent progress. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
|
21
|
Xia S, Chen Y, Fu W, Tian J, Zhou Y, Sun Y, Cao R, Zou H, Liang M. A humidity-resistant bio-inspired microfibrillar adhesive fabricated using a phenyl-rich polysiloxane elastomer for reliable skin patches. J Mater Chem B 2022; 10:9179-9187. [PMID: 36341761 DOI: 10.1039/d2tb01955h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Steady adhesion under varying humidity conditions is fundamentally challenging due to the barrier of interfacial water molecules. Here, we demonstrate a humidity-resistant gecko-inspired microfibrillar adhesive fabricated by using a specific phenyl-rich polysiloxane. In contrast with the great decline of macroadhesion with increasing humidity for the typical polydimethylsiloxane (PDMS) microfibrillar adhesives, strong macroadhesion of a microfibrillar adhesive fabricated using synthetic phenyl-rich polysiloxane maintains adhesion well across a wide relative humidity range (1% to 95%). Moreover, the pull-off strength is increased by 500% compared to that of phenyl-absent PDMS microfibrillar adhesives at extremely high humidity. Mechanism analysis demonstrates that the synergistic interplay of strong interfacial hydrophobicity leading to dry contact and bulk energy dissipation through massive aromatic π-π interactions contributes greatly to the reliable and strong humidity macroadhesion. The present results provide a better understanding of humidity macroadhesion as well as application potential for microfibrillar adhesives, which are proven to be reliable skin adhesive patches for long-term health-care that have to be exposed to varying humidity conditions of the skin surface.
Collapse
Affiliation(s)
- Shuang Xia
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Yukun Chen
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Wenxin Fu
- Key Laboratory of Science and Technology on High-tech Polymer Materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Jinfeng Tian
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Yilin Zhou
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Yini Sun
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Ruoxuan Cao
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Huawei Zou
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| | - Mei Liang
- The State Key Laboratory of Polymer Materials Engineering, Polymer Research Institute of Sichuan University, Chengdu 610065, China.
| |
Collapse
|
22
|
Zhang Q, Ji K, Huo T, Khan MN, Hu Z, Yuan C, Zhao J, Chen J, Wang Z, Dai Z. Biomimetic Patch with Wicking-Breathable and Multi-mechanism Adhesion for Bioelectrical Signal Monitoring. ACS APPLIED MATERIALS & INTERFACES 2022; 14:48438-48448. [PMID: 36259961 DOI: 10.1021/acsami.2c13984] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Wearable bioelectrical monitoring devices can provide long-term human health information such as electrocardiogram and other physiological signals. It is a crucial part of the remote medical system. These can provide prediction for the diagnosis and treatment of cardiovascular disease and access to timely treatment. However, the patch comfort of the wearable monitoring devices in long-term contact with the skin have been a technical bottleneck of the hardware. In this study, the biomimetic patch with wicking-breathable and multi-mechanism adhesion performance to achieve adaptability and comfortability to human skin has been reported. The patch was designed based on a conical through-hole and hexagonal microgroove to directionally transport sweat from skin to air which gives the patch the breathable performance. The breathable and drainage capability of the biomimetic patch was experimentally verified by analyzing the conical through-hole and hexagonal microgroove with the structural mechanism of wicking. Multi-mechanism adhesion of the Ag/Ni microneedle array and PDMS-t adhesion material ensures the stability of patch signal acquisition. This study provides a new way for enhancing the breathability and adaptability of the patch to realize accurate bioelectrical signal monitoring under sweat conditions on human skin.
Collapse
Affiliation(s)
- Qian Zhang
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Keju Ji
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Tingwei Huo
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Muhammad Niaz Khan
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Zhuoyang Hu
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Cong Yuan
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Jiahui Zhao
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Jian Chen
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Zhouyi Wang
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Zhendong Dai
- Jiangsu Provincial Key Laboratory of Bionic Functional Materials, College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| |
Collapse
|
23
|
Moreira Lana G, Zhang X, Müller C, Hensel R, Arzt E. Film-Terminated Fibrillar Microstructures with Improved Adhesion on Skin-like Surfaces. ACS APPLIED MATERIALS & INTERFACES 2022; 14:46239-46251. [PMID: 36195314 PMCID: PMC9586108 DOI: 10.1021/acsami.2c12663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 09/16/2022] [Indexed: 06/16/2023]
Abstract
Adhesives for interaction with human skin and tissues are needed for multiple applications. Micropatterned dry adhesives are potential candidates, allowing for a conformal contact and glue-free adhesion based on van der Waals interactions. In this study, we investigate the superior adhesion of film-terminated fibrillar microstructures (fibril diameter, 60 μm; aspect ratio, 3) in contact with surfaces of skin-like roughness (Rz 50 μm). Adhesion decays only moderately with increasing roughness, in contrast to unstructured samples. Sinusoidal model surfaces adhere when their wavelengths exceed about four fibril diameters. The film-terminated microstructure exhibits a saturation of the compressive force during application, implying a pressure safety regime protecting delicate counter surfaces. Applications of this novel adhesive concept are foreseen in the fields of wearable electronics and wound dressing.
Collapse
Affiliation(s)
- Gabriela Moreira Lana
- INM—Leibniz
Institute for New Materials, Campus D2 2, 66123Saarbrücken, Germany
- Department
of Materials Science and Engineering, Saarland
University, Campus D2
2, 66123Saarbrücken, Germany
| | - Xuan Zhang
- INM—Leibniz
Institute for New Materials, Campus D2 2, 66123Saarbrücken, Germany
| | - Christian Müller
- INM—Leibniz
Institute for New Materials, Campus D2 2, 66123Saarbrücken, Germany
| | - René Hensel
- INM—Leibniz
Institute for New Materials, Campus D2 2, 66123Saarbrücken, Germany
| | - Eduard Arzt
- INM—Leibniz
Institute for New Materials, Campus D2 2, 66123Saarbrücken, Germany
- Department
of Materials Science and Engineering, Saarland
University, Campus D2
2, 66123Saarbrücken, Germany
| |
Collapse
|
24
|
Cao J, Yang X, Rao J, Mitriashkin A, Fan X, Chen R, Cheng H, Wang X, Goh J, Leo HL, Ouyang J. Stretchable and Self-Adhesive PEDOT:PSS Blend with High Sweat Tolerance as Conformal Biopotential Dry Electrodes. ACS APPLIED MATERIALS & INTERFACES 2022; 14:39159-39171. [PMID: 35973944 DOI: 10.1021/acsami.2c11921] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Dry epidermal electrodes that can always form conformal contact with skin can be used for continuous long-term biopotential monitoring, which can provide vital information for disease diagnosis and rehabilitation. But, this application has been limited by the poor contact of dry electrodes on wet skin. Herein, we report a biocompatible fully organic dry electrode that can form conformal contact with both dry and wet skin even during physical movement. The dry electrodes are prepared by drop casting an aqueous solution consisting of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS), poly(vinyl alcohol) (PVA), tannic acid (TA), and ethylene glycol (EG). The electrodes can exhibit a conductivity of 122 S cm-1 and a mechanical stretchability of 54%. Moreover, they are self-adhesive to not only dry skin but also wet skin. As a result, they can exhibit a lower contact impedance to skin than commercial Ag/AgCl gel electrodes on both dry and sweat skins. They can be used as dry epidermal electrodes to accurately detect biopotential signals including electrocardiogram (ECG) and electromyogram (EMG) on both dry and wet skins for the users at rest or during physical movement. This is the first time to demonstrate dry epidermal electrodes self-adhesive to wet skin for accurate biopotential detection.
Collapse
Affiliation(s)
- Jian Cao
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117574
| | - Xingyi Yang
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117574
| | - Jiancheng Rao
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117574
| | - Aleksandr Mitriashkin
- Biomedical Engineering Department, College of Design and Engineering, National University of Singapore, Singapore 117574
| | - Xing Fan
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117574
| | - Rui Chen
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117574
| | - Hanlin Cheng
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117574
| | - Xinchao Wang
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117574
| | - James Goh
- Biomedical Engineering Department, College of Design and Engineering, National University of Singapore, Singapore 117574
| | - Hwa Liang Leo
- Biomedical Engineering Department, College of Design and Engineering, National University of Singapore, Singapore 117574
| | - Jianyong Ouyang
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117574
- NUS Research Institute, No. 16 South Huashan Road, Liangjiang New Area, Chongqing 119077, China
| |
Collapse
|
25
|
Kim Y, Suh JM, Shin J, Liu Y, Yeon H, Qiao K, Kum HS, Kim C, Lee HE, Choi C, Kim H, Lee D, Lee J, Kang JH, Park BI, Kang S, Kim J, Kim S, Perozek JA, Wang K, Park Y, Kishen K, Kong L, Palacios T, Park J, Park MC, Kim HJ, Lee YS, Lee K, Bae SH, Kong W, Han J, Kim J. Chip-less wireless electronic skins by remote epitaxial freestanding compound semiconductors. Science 2022; 377:859-864. [PMID: 35981034 DOI: 10.1126/science.abn7325] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Recent advances in flexible and stretchable electronics have led to a surge of electronic skin (e-skin)-based health monitoring platforms. Conventional wireless e-skins rely on rigid integrated circuit chips that compromise the overall flexibility and consume considerable power. Chip-less wireless e-skins based on inductor-capacitor resonators are limited to mechanical sensors with low sensitivities. We report a chip-less wireless e-skin based on surface acoustic wave sensors made of freestanding ultrathin single-crystalline piezoelectric gallium nitride membranes. Surface acoustic wave-based e-skin offers highly sensitive, low-power, and long-term sensing of strain, ultraviolet light, and ion concentrations in sweat. We demonstrate weeklong monitoring of pulse. These results present routes to inexpensive and versatile low-power, high-sensitivity platforms for wireless health monitoring devices.
Collapse
Affiliation(s)
- Yeongin Kim
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Department of Electrical Engineering and Computer Science, University of Cincinnati, Cincinnati, OH 45219, USA
| | - Jun Min Suh
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jiho Shin
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Yunpeng Liu
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Hanwool Yeon
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,School of Materials Science and Engineering, Gwangju Institute of Science and Technology, Gwangju 61005, South Korea
| | - Kuan Qiao
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Hyun S Kum
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Department of Electrical and Electronic Engineering, Yonsei University, Seoul 03722, South Korea
| | - Chansoo Kim
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Han Eol Lee
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Division of Advanced Materials Engineering, Jeonbuk National University, Jeonju 54896, South Korea
| | - Chanyeol Choi
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Hyunseok Kim
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Doyoon Lee
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jaeyong Lee
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ji-Hoon Kang
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Bo-In Park
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Sungsu Kang
- School of Chemical and Biological Engineering, Institute of Chemical Process, Seoul National University, Seoul 08826, South Korea
| | - Jihoon Kim
- School of Chemical and Biological Engineering, Institute of Chemical Process, Seoul National University, Seoul 08826, South Korea
| | - Sungkyu Kim
- Department of Nanotechnology and Advanced Materials Engineering, Sejong University, Seoul 05006, South Korea
| | - Joshua A Perozek
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Kejia Wang
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,School of Micro-Nano Electronics, Zhejiang University, Hangzhou 311200 Zhejiang, People's Republic of China
| | - Yongmo Park
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Kumar Kishen
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Lingping Kong
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Tomás Palacios
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jungwon Park
- School of Chemical and Biological Engineering, Institute of Chemical Process, Seoul National University, Seoul 08826, South Korea.,Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, South Korea
| | - Min-Chul Park
- Post-Silicon Semiconductor Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, South Korea
| | - Hyung-Jun Kim
- Post-Silicon Semiconductor Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, South Korea.,Division of Nano and Information Technology, KIST School, Korea University of Science and Technology, Seoul 02792, South Korea
| | - Yun Seog Lee
- Department of Mechanical Engineering, Seoul National University, Seoul 08826, South Korea
| | - Kyusang Lee
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA
| | - Sang-Hoon Bae
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, MO 63139, USA
| | - Wei Kong
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Department of Materials Science and Engineering, Westlake University, Hangzhou 310024 Zhejiang, People's Republic of China
| | - Jiyeon Han
- Skincare Division, Amorepacific R&D Center, Yongin 17074, South Korea
| | - Jeehwan Kim
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.,Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
26
|
Niu X, Gao X, Wang T, Wang W, Liu H. Ordered Nanopillar Arrays of Low Dynamic Noise Dry Bioelectrodes for Electrocardiogram Surface Monitoring. ACS APPLIED MATERIALS & INTERFACES 2022; 14:33861-33870. [PMID: 35830904 DOI: 10.1021/acsami.2c08318] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Flexible bioelectric dry electrodes are an important part of long-term medical healthcare monitoring systems. In this study, a new method is proposed for the preparation of dry electrodes with micronanopillar arrays structured by designing dimensionally tunable anodized aluminum oxide (AAO) templates, by which polyaniline/thermoplastic polyurethane single-layer micronanopillar array structured dry electrodes (PANI/TPU-SE) and polyaniline/thermoplastic polyurethane double-layer micronanopillar array structured dry electrodes (PANI/TPU-DE) are prepared. Compared with the planar structure, the micronanopillar array structure can reduce the contact gap between the electrode and skin and increase the contact area, thus exhibiting lower contact impedance and higher signal quality. At 0.1 Hz, the impedances of the wet electrode, PANI/TPU-DE300, PANI/TPU-SE10, and planar structure electrodes are 269.5 kΩ, 375.5 kΩ, 398.1 kΩ, and 2.257 MΩ, respectively, and the impedance value for PANI/TPU-DE300 is smaller than that for PANI/TPU-SE10 and closer to that for the wet electrode. In addition, because the surface of the micronanostructure can conform to the human skin, about 210.7% increase in the peel strength of double-layer structure electrodes compared to flat structure electrodes, it shows a low baseline drift in the dynamic ECG measurement, and the signal-to-noise ratio in the walking state can reach 21.33 ± 5.4775 dB. Therefore, the prepared bioelectric dry electrode has a wide application prospect in the fields of wearable medical monitoring.
Collapse
Affiliation(s)
- Xin Niu
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Xinhua Gao
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Tanyu Wang
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Wei Wang
- School of Arts, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Hao Liu
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| |
Collapse
|
27
|
Wang X, Liu Y, Cheng H, Ouyang X. Surface Wettability for Skin-Interfaced Sensors and Devices. ADVANCED FUNCTIONAL MATERIALS 2022; 32:2200260. [PMID: 36176721 PMCID: PMC9514151 DOI: 10.1002/adfm.202200260] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Indexed: 05/05/2023]
Abstract
The practical applications of skin-interfaced sensors and devices in daily life hinge on the rational design of surface wettability to maintain device integrity and achieve improved sensing performance under complex hydrated conditions. Various bio-inspired strategies have been implemented to engineer desired surface wettability for varying hydrated conditions. Although the bodily fluids can negatively affect the device performance, they also provide a rich reservoir of health-relevant information and sustained energy for next-generation stretchable self-powered devices. As a result, the design and manipulation of the surface wettability are critical to effectively control the liquid behavior on the device surface for enhanced performance. The sensors and devices with engineered surface wettability can collect and analyze health biomarkers while being minimally affected by bodily fluids or ambient humid environments. The energy harvesters also benefit from surface wettability design to achieve enhanced performance for powering on-body electronics. In this review, we first summarize the commonly used approaches to tune the surface wettability for target applications toward stretchable self-powered devices. By considering the existing challenges, we also discuss the opportunities as a small fraction of potential future developments, which can lead to a new class of skin-interfaced devices for use in digital health and personalized medicine.
Collapse
Affiliation(s)
- Xiufeng Wang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Yangchengyi Liu
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
| | - Xiaoping Ouyang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China
| |
Collapse
|
28
|
Graphene-Based Flexible Electrode for Electrocardiogram Signal Monitoring. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094526] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
With the rapidly aging society and increased concern for personal cardiovascular health, novel, flexible electrodes suitable for electrocardiogram (ECG) signal monitoring are in demand. Based on the excellent electrical and mechanical properties of graphene and the rapid development of graphene device fabrication technologies, graphene-based ECG electrodes have recently attracted much attention, and many flexible graphene electrodes with excellent performance have been developed. To understand the current research progress of graphene-based ECG electrodes and help researchers clarify current development conditions and directions, we systematically review the recent advances in graphene-based flexible ECG electrodes. Graphene electrodes are classified as bionic, fabric-based, biodegradable, laser-induced/scribed, modified-graphene, sponge-like, invasive, etc., based on their design concept, structural characteristics, preparation methods, and material properties. Moreover, some categories are further divided into dry or wet electrodes. Then, their performance, including electrode–skin impedance, signal-to-noise ratio, skin compatibility, and stability, is analyzed. Finally, we discuss possible development directions of graphene ECG electrodes and share our views.
Collapse
|
29
|
Kim H, Kim E, Choi C, Yeo WH. Advances in Soft and Dry Electrodes for Wearable Health Monitoring Devices. MICROMACHINES 2022; 13:mi13040629. [PMID: 35457934 PMCID: PMC9029742 DOI: 10.3390/mi13040629] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/12/2022] [Accepted: 04/13/2022] [Indexed: 01/20/2023]
Abstract
Electrophysiology signals are crucial health status indicators as they are related to all human activities. Current demands for mobile healthcare have driven considerable interest in developing skin-mounted electrodes for health monitoring. Silver-Silver chloride-based (Ag-/AgCl) wet electrodes, commonly used in conventional clinical practice, provide excellent signal quality, but cannot monitor long-term signals due to gel evaporation and skin irritation. Therefore, the focus has shifted to developing dry electrodes that can operate without gels and extra adhesives. Compared to conventional wet electrodes, dry ones offer various advantages in terms of ease of use, long-term stability, and biocompatibility. This review outlines a systematic summary of the latest research on high-performance soft and dry electrodes. In addition, we summarize recent developments in soft materials, biocompatible materials, manufacturing methods, strategies to promote physical adhesion, methods for higher breathability, and their applications in wearable biomedical devices. Finally, we discuss the developmental challenges and advantages of various dry electrodes, while suggesting research directions for future studies.
Collapse
Affiliation(s)
- Hyeonseok Kim
- Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332, USA; (H.K.); (E.K.); (C.C.)
- IEN Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Eugene Kim
- Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332, USA; (H.K.); (E.K.); (C.C.)
| | - Chanyeong Choi
- Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332, USA; (H.K.); (E.K.); (C.C.)
| | - Woon-Hong Yeo
- Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332, USA; (H.K.); (E.K.); (C.C.)
- IEN Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
- Parker H. Petit Institute for Bioengineering and Biosciences, Neural Engineering Center, Institute for Materials, Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Correspondence: ; Tel.: +1-404-385-5710
| |
Collapse
|
30
|
Lee SH, Kang BS, Kwak MK. Magneto-Responsive Actuating Surfaces with Controlled Wettability and Optical Transmittance. ACS APPLIED MATERIALS & INTERFACES 2022; 14:14721-14728. [PMID: 35289610 DOI: 10.1021/acsami.1c24556] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The wettability of surfaces can be manipulated using actuating micro/nanostructures, as in the manipulation of water droplets with magnetic forces. Controlling water droplets with magneto-responsive surfaces is limited to optical applications, however, because these surfaces are normally opaque. Herein, we introduce a magneto-responsive actuating surface that is capable of controlling not only the wettability but also the optical transmittance. The magneto-responsive actuating surface is fabricated using a composite of iron particles with polydimethylsiloxane (PDMS). Thanks to the elastic properties of PDMS, fabricated microstructures' bending is induced by applying magnetic force. Therefore, the static/dynamic water contact angle and the optical transmittance can be controlled. Furthermore, as a feasible application, a sliding angle control system that depends on the magnet location is implemented. On the basis of the interesting characteristics of not only wettability but also optical transmittance, this study is expected to be widely used in various fields such as optics, surface self-cleaning systems of solar cells, and smart windows.
Collapse
Affiliation(s)
- Sung Ho Lee
- Department of Electrical Electronics and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Bong Su Kang
- Department of Mechanical Engineering, Kyungpook National University, Daegu 41566, Republic of Korea
| | - Moon Kyu Kwak
- Department of Mechanical Engineering, Kyungpook National University, Daegu 41566, Republic of Korea
| |
Collapse
|
31
|
Horbelt N, Fratzl P, Harrington MJ. Mistletoe viscin: a hygro- and mechano-responsive cellulose-based adhesive for diverse material applications. PNAS NEXUS 2022; 1:pgac026. [PMID: 36712808 PMCID: PMC9802232 DOI: 10.1093/pnasnexus/pgac026] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 01/07/2022] [Accepted: 03/09/2022] [Indexed: 04/23/2023]
Abstract
Mistletoe viscin is a natural cellulosic adhesive consisting of hierarchically organized cellulose microfibrils (CMFs) surrounded by a humidity-responsive matrix that enables mechanical drawing into stiff and sticky fibers. Here, we explored the processability and adhesive capacity of viscin and demonstrated its potential as a source material for various material applications, as well as a source for bioinspired design. Specifically, we revealed that viscin fibers exhibit humidity-activated self-adhesive properties that enable "contact welding" into complex 2D and 3D architectures under ambient conditions. We additionally discovered that viscin can be processed into stiff and transparent free-standing films via biaxial stretching in the hydrated state, followed by drying, whereby CMFs align along local stress fields. Furthermore, we determined that viscin adheres strongly to both synthetic materials (metals, plastics, and glass) and biological tissues, such as skin and cartilage. In particular, skin adhesion makes viscin a compelling candidate as a wound sealant, as we further demonstrate. These findings highlight the enormous potential of this hygro- and mechano-responsive fiber-reinforced adhesive for bioinspired and biomedical applications.
Collapse
Affiliation(s)
- Nils Horbelt
- Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, Potsdam 14424, Germany
| | - Peter Fratzl
- Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, Potsdam 14424, Germany
| | - Matthew J Harrington
- To whom correspondence should be addressed: Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec H3A 0B8, Canada.
| |
Collapse
|
32
|
Ma X, Bian Q, Hu J, Gao J. Stem from nature: Bioinspired adhesive formulations for wound healing. J Control Release 2022; 345:292-305. [DOI: 10.1016/j.jconrel.2022.03.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 03/13/2022] [Accepted: 03/14/2022] [Indexed: 12/27/2022]
|
33
|
Lee SH, Song HW, Park HJ, Kwak MK. Surface Adaptable and Adhesion Controllable Dry Adhesive with Shape Memory Polymer. Macromol Rapid Commun 2022; 43:e2200012. [PMID: 35132723 DOI: 10.1002/marc.202200012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 02/01/2022] [Indexed: 11/08/2022]
Abstract
Gecko foot consist of numerous micro/nano hierarchical hairs and exhibit a high adhesion onto various surfaces by the "van der Waals force". The gecko, despite its mighty adhesion, can travel efficiently with a rapid adhesion switching given that the end of hair in the gecko foot is slanted in one direction. Herein, we report a shape memory polymer (SMP)-based switchable dry adhesive (SSA), inspired by gecko foot, having tremendous surface adaptability and adhesion switching capability. The SSA shows not only high adhesion to the various surfaces (approximately 332.8 kPa) but also easy detachment (nearly 3.73 kPa) due to the characteristic of SMP, which can reversibly recover from a deformed shape to its initial shape. On the basis of the novel adhesion switching property, we suggest the SSA-applied advanced glass transfer system as a feasible application. This experiment confirms that an ultra-thin and light glass film is transferred easily and sustainably, and we believe that the SSA might be a breakthrough and a powerful alternative for not only conventional dry adhesive but also the next-level transfer systems. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Sung Ho Lee
- Department of Electrical Electronics and Computer Science, University of Michigan, Ann Arbor, 48109, United States
| | - Hyun Woo Song
- Department of Mechanical Engineering, Kyungpook National University, Daegu, 41566, Republic of Korea
| | - Han Jun Park
- Department of Mechanical Engineering, Kyungpook National University, Daegu, 41566, Republic of Korea
| | - Moon Kyu Kwak
- Department of Mechanical Engineering, Kyungpook National University, Daegu, 41566, Republic of Korea
| |
Collapse
|
34
|
Effect of electron irradiation on few-layer boron nitride nanosheets/polydimethylsiloxane composite inspired pillar. Chem Phys Lett 2022. [DOI: 10.1016/j.cplett.2021.139243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
35
|
Hassan A, Kim Y, Ryu S, Hatton B, Filleter T. Divisions in a Fibrillar Adhesive Increase the Adhesive Strength. ACS APPLIED MATERIALS & INTERFACES 2021; 13:59478-59486. [PMID: 34847669 DOI: 10.1021/acsami.1c17663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
To realize the potential of bioinspired fibrillar adhesive applications ranging from biomedical devices to robotic grippers, there has been a significant effort to improve their adhesive strength and understanding of the underlying adhesion and detachment mechanisms. These efforts include changes to the backing layer, which connects the roots of all of the pillars in the fibrillar adhesive. However, previous approaches such as thickness or elastic modulus changes are selectively advantageous to the adhesive strength depending on the substrate condition because of the trade-off between conformity to misaligned/rough surfaces and increased interfacial stress concentrations. In this work, we explore mechanical divisions (cuts) in the backing layer as a new approach to improve the adhesive strength without this trade-off. We combine experiments and finite element analysis (FEA) to study the effect of the divisions, which decouples the mechanical interaction between the pillars on the divided layers, and show that the adhesive strength can be improved regardless of the substrate condition. Tensile adhesion experiments show increased adhesive strength with cuts to a micropost array (150 μm diameter posts) by approximately 25% for 4 divisions. In situ imaging of pillar detachment shows a transition of the detachment process from a peel-like detachment to a random detachment sequence. FEA simulations of the detachment process suggest that the increased strength may originate from a simultaneous enhancement of the load distribution between the pillars and the compliance of the backing layer.
Collapse
Affiliation(s)
- Aly Hassan
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S3G8, Canada
| | - Yongtae Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Seunghwa Ryu
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Benjamin Hatton
- Department of Materials Science and Engineering, University of Toronto, Toronto, ON M5S1A1, Canada
| | - Tobin Filleter
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S3G8, Canada
| |
Collapse
|
36
|
Son D, Liimatainen V, Sitti M. Machine Learning-Based and Experimentally Validated Optimal Adhesive Fibril Designs. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2102867. [PMID: 34414656 DOI: 10.1002/smll.202102867] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Indexed: 06/13/2023]
Abstract
Setae, fibrils located on a gecko's feet, have been an inspiration of synthetic dry microfibrillar adhesives in the last two decades for a wide range of applications due to unique properties: residue-free, repeatable, tunable, controllable and silent adhesion; self-cleaning; and breathability. However, designing dry fibrillar adhesives is limited by a template-based-design-approach using a pre-determined bioinspired T- or wedge-shaped mushroom tip. Here, a machine learning-based computational approach to optimize designs of adhesive fibrils is shown, exploring a much broader design space. A combination of Bayesian optimization and finite element methods creates novel optimal designs of adhesive fibrils, which are fabricated by two-photon-polymerization-based 3D microprinting and double-molding-based replication out of polydimethylsiloxane. Such optimal elastomeric fibril designs outperform previously proposed designs by maximum 77% in the experiments of dry adhesion performance on smooth surfaces. Furthermore, finite-element-analyses reveal that the adhesion of the fibrils is sensitive to the 3D fibril stem shape, tensile deformation, and fibril microfabrication limits, which contrast with the previous assumptions that mostly neglect the deformation of the fibril tip and stem, and focus only on the fibril tip geometry. The proposed computational fibril design could help design future optimal fibrils with less help from human intuition.
Collapse
Affiliation(s)
- Donghoon Son
- School of Mechanical Engineering, Pusan National University, Busan, 46241, South Korea
- Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany
| | - Ville Liimatainen
- Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany
- Okmetic Oy, Vantaa, 01510, Finland
| | - Metin Sitti
- Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany
- Institute for Biomedical Engineering, ETH Zurich, Zurich, 8092, Switzerland
- School of Medicine and College of Engineering, Koç University, Istanbul, 34450, Turkey
| |
Collapse
|
37
|
Li S, Liu H, Tian H, Wang C, Wang D, Wu Y, Shao J. Dytiscus lapponicus-Inspired Structure with High Adhesion in Dry and Underwater Environments. ACS APPLIED MATERIALS & INTERFACES 2021; 13:42287-42296. [PMID: 34455771 DOI: 10.1021/acsami.1c13604] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The epidermal adhesive structure of many animals generates reliable adhesion on their engaged surfaces. However, current bio-inspired adhesion structures are difficult to function well in dry and underwater environments simultaneously. Interestingly, the male Dytiscus lapponicus attaches firmly to the rough shell of the female D. lapponicus in both dry and underwater conditions owing to the adhesive setae of its forelegs, and to the best of our knowledge, designing adhesive structures on multienvironments has never been reported. Here, a D. lapponicus-inspired adhesion structure (DIAS) is proposed and fabricated using double-exposure-fill molding technology accompanied with the material curing shrinkage, in which different structural features could be achieved by varying curing shrinkage ratios, elastic moduli, and back exposure time. The DIAS offered high, reversible, and repeatable strength in dry and underwater conditions with values of 205 and 133 kPa, respectively. By comparing the adhesion properties of different shapes via testing experiments and numerical analysis, a structural feature with an inclination of 15° was found to be optimal. Finally, the potential application of the DIAS in flexible electronic smart skin-attachable devices was demonstrated on a pig skin, paving the way for further bio-inspired adhesive designs for both dry and wet scenarios.
Collapse
Affiliation(s)
- Shuai Li
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Haoran Liu
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Hongmiao Tian
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Chunhui Wang
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Duorui Wang
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Yihang Wu
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| | - Jinyou Shao
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
| |
Collapse
|
38
|
Sorg K, Heimann L, Lana GM, Langenbucher A, Schick B, Arzt E, Wenzel GI. Optoacoustically induced auditory brainstem responses in the mouse model enhanced through an absorbing film. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210173R. [PMID: 34480448 PMCID: PMC8414560 DOI: 10.1117/1.jbo.26.9.098001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 08/17/2021] [Indexed: 06/13/2023]
Abstract
SIGNIFICANCE Optoacoustic stimulation offers an alternative stimulation strategy for the hearing organ. To serve as the base for a novel auditory prosthesis, the optoacoustic stimulation must be biocompatible and energy-saving. AIM Enhancing the efficiency of optoacoustic stimulation while reducing the energy input in a suited animal model. APPROACH Optoacoustically induced auditory brainstem responses (oABRs) were recorded after the pulsed laser irradiation of the tympanic membrane (TM) in mice. The results were compared with the ABRs induced through acoustic click stimulation. In addition, self-adhesive absorbing films were applied on the TM before the optoacoustic stimulation to investigate their effect on the resulting ABRs. RESULTS Using an absorbing film on the TM during optical stimulation led to considerably enhanced oABR wave I amplitude values compared with the stimulation of the bare TM. When using our stimulation strategy, we induced oABR waves in the 50% to 60% range of the acoustical stimulation reached with 80-dB SPL click stimuli. CONCLUSIONS The mouse model can be used for certain developmental work for an optoacoustic auditory prosthesis. Using absorbing films on the TM during optical stimulation considerably enhances oABR wave I amplitude. Optimization of the stimulation strategy could further enhance the efficiency within biocompatibility margins.
Collapse
Affiliation(s)
- Katharina Sorg
- Saarland University Medical Center, Department of Otorhinolaryngology, Homburg, Germany
| | - Larissa Heimann
- Saarland University Medical Center, Department of Otorhinolaryngology, Homburg, Germany
| | - Gabriela Moreira Lana
- INM Leibniz Institute for New Materials, Saarbrücken, Germany
- Saarland University, Department of Materials Science and Engineering, Saarbrücken, Germany
| | - Achim Langenbucher
- Saarland University, Department of Experimental Ophthalmology, Homburg, Germany
| | - Bernhard Schick
- Saarland University Medical Center, Department of Otorhinolaryngology, Homburg, Germany
| | - Eduard Arzt
- INM Leibniz Institute for New Materials, Saarbrücken, Germany
- Saarland University, Department of Materials Science and Engineering, Saarbrücken, Germany
| | - Gentiana Ioana Wenzel
- Saarland University Medical Center, Department of Otorhinolaryngology, Homburg, Germany
| |
Collapse
|
39
|
Park J, Kim Y, Chun B, Seo J. Rational engineering and applications of functional bioadhesives in biomedical engineering. Biotechnol J 2021; 16:e2100231. [PMID: 34469052 DOI: 10.1002/biot.202100231] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 08/24/2021] [Accepted: 08/30/2021] [Indexed: 12/31/2022]
Abstract
For the past decades, several bioadhesives have been developed to replace conventional wound closure medical tools such as sutures, staples, and clips. The bioadhesives are easy to use and can minimize tissue damage. They are designed to provide strong adhesion with stable mechanical support on tissue surfaces. However, this monofunctionality of the bioadhesives hinders their practical applications. In particular, a bioadhesive can lose its intended function under harsh tissue environments or delay tissue regeneration during wound healing. Based on several natural and synthetic biomaterials, functional bioadhesives have been developed to overcome the aforementioned limitations. The functional bioadhesives are designed to have specific characteristics such as antimicrobial, cell infiltrative, stimuli-responsive, electrically conductive, and self-healing to ensure stability under harsh tissue conditions, facilitate tissue regeneration, and effectively monitor biosignals. Herein, we thoroughly review the functional bioadhesives from their fundamental background to recent progress with their practical applications for the enhancement of tissue healing and effective biosignal sensing. Furthermore, the future perspectives on the applications of functional bioadhesives and current challenges in their commercialization are also discussed.
Collapse
Affiliation(s)
- Jae Park
- Biological Interfaces and Sensor Systems Laboratory, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Yeonju Kim
- Biological Interfaces and Sensor Systems Laboratory, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Beomsoo Chun
- Biological Interfaces and Sensor Systems Laboratory, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Jungmok Seo
- Biological Interfaces and Sensor Systems Laboratory, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
40
|
Abstract
Electrodermal devices that capture the physiological response of skin are crucial for monitoring vital signals, but they often require convoluted layered designs with either electronic or ionic active materials relying on complicated synthesis procedures, encapsulation, and packaging techniques. Here, we report that the ionic transport in living systems can provide a simple mode of iontronic sensing and bypass the need of artificial ionic materials. A simple skin-electrode mechanosensing structure (SEMS) is constructed, exhibiting high pressure-resolution and spatial-resolution, being capable of feeling touch and detecting weak physiological signals such as fingertip pulse under different skin humidity. Our mechanical analysis reveals the critical role of instability in high-aspect-ratio microstructures on sensing. We further demonstrate pressure mapping with millimeter-spatial-resolution using a fully textile SEMS-based glove. The simplicity and reliability of SEMS hold great promise of diverse healthcare applications, such as pulse detection and recovering the sensory capability in patients with tactile dysfunction. Sensing mechanical signals is an important aspect for a range of applications of E-skins. Here, the authors report on the creation of deforming iontronic sensing structures which can use ionic transport through tissues to create a simple and sensitive E-skin for sensing touch, pulse and motion demonstrating application.
Collapse
|
41
|
Adhesive performance enhancement of the mushroom-shaped microstructured elastomer by atmospheric plasma treatment. Biointerphases 2021; 16:041004. [PMID: 34301148 DOI: 10.1116/6.0000999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Bioinspired reversible adhesives that have been developed in the course of recent years have found several applications in robotics, transportation, and marine applications. One of their prominent features is strong reversible static adhesion. To fulfill the requirements of various applications, the static adhesive performance of these materials can be enhanced by modifying the material and surface properties. In this work, the mushroom-shaped adhesive microstructured surface was functionalized by atmospheric plasma treatment to enhance its adhesive performances. Through optimizing the duration of the treatment, the pull-off force increase of up to 60% can be reached after the treatment in comparison to the measurements performed on the same mushroom-shaped microstructured sample before the treatment. In comparison to the microstructured samples, the attachment of the unstructured sample made of the same silicone elastomer was enhanced by 16% after plasma treatment. The strong adhesion enhancement on the microstructured sample was attributed to the combination of the changed effective elastic modulus of the material and the specific detachment behavior of microstructures. These results are anticipated to contribute to the further development of bioinspired dry adhesives and may potentially widen their usage in various technological applications.
Collapse
|
42
|
Barbieri L, Sorzabal Bellido I, Beckett AJ, Prior IA, Fothergill J, Diaz Fernandez YA, Raval R. One-step preparation of antimicrobial silicone materials based on PDMS and salicylic acid: insights from spatially and temporally resolved techniques. NPJ Biofilms Microbiomes 2021; 7:51. [PMID: 34155220 PMCID: PMC8217222 DOI: 10.1038/s41522-021-00223-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 05/12/2021] [Indexed: 11/09/2022] Open
Abstract
In this work, we introduce a one-step strategy that is suitable for continuous flow manufacturing of antimicrobial PDMS materials. The process is based on the intrinsic capacity of PDMS to react to certain organic solvents, which enables the incorporation of antimicrobial actives such as salicylic acid (SA), which has been approved for use in humans within pharmaceutical products. By combining different spectroscopic and imaging techniques, we show that the surface properties of PDMS remain unaffected while high doses of the SA are loaded inside the PDMS matrix. The SA can be subsequently released under physiological conditions, delivering a strong antibacterial activity. Furthermore, encapsulation of SA inside the PDMS matrix ensured a diffusion-controlled release that was tracked by spatially resolved Raman spectroscopy, Attenuated Total Reflectance IR (ATR-IR), and UV-Vis spectroscopy. The biological activity of the new material was evaluated directly at the surface and in the planktonic state against model pathogenic bacteria, combining confocal laser scanning microscopy, electron microscopy, and cell viability assays. The results showed complete planktonic inhibition for clinically relevant strains of Staphylococcus aureus and Escherichia coli, and a reduction of up to 4 orders of magnitude for viable sessile cells, demonstrating the efficacy of these surfaces in preventing the initial stages of biofilm formation. Our approach adds a new option to existing strategies for the antimicrobial functionalisation of a wide range of products such as catheters, wound dressings and in-dwelling medical devices based on PDMS.
Collapse
Affiliation(s)
- Luca Barbieri
- Open Innovation Hub for Antimicrobial Surfaces, Department of Chemistry, University of Liverpool & National Biofilm Innovation Centre, Liverpool, UK
- Institute of Infection and Global Health, University of Liverpool, Liverpool, UK
| | - Ioritz Sorzabal Bellido
- Open Innovation Hub for Antimicrobial Surfaces, Department of Chemistry, University of Liverpool & National Biofilm Innovation Centre, Liverpool, UK
| | - Alison J Beckett
- Biomedical Electron Microscopy Unit, University of Liverpool, Liverpool, UK
| | - Ian A Prior
- Biomedical Electron Microscopy Unit, University of Liverpool, Liverpool, UK
| | - Jo Fothergill
- Institute of Infection and Global Health, University of Liverpool, Liverpool, UK
| | - Yuri A Diaz Fernandez
- Open Innovation Hub for Antimicrobial Surfaces, Department of Chemistry, University of Liverpool & National Biofilm Innovation Centre, Liverpool, UK.
| | - Rasmita Raval
- Open Innovation Hub for Antimicrobial Surfaces, Department of Chemistry, University of Liverpool & National Biofilm Innovation Centre, Liverpool, UK.
| |
Collapse
|
43
|
Abstract
Flexible bioelectronics have promising applications in electronic skin, wearable devices, biomedical electronics, etc. Hydrogels have unique advantages for bioelectronics due to their tissue-like mechanical properties and excellent biocompatibility. Particularly, conductive and tissue adhesive hydrogels can self-adhere to bio-tissues and have great potential in implantable wearable bioelectronics. This review focuses on the recent progress in tissue adhesive hydrogel bioelectronics, including the mechanism and preparation of tissue adhesive hydrogels, the fabrication strategies of conductive hydrogels, and tissue adhesive hydrogel bioelectronics and applications. Some perspectives on tissue adhesive hydrogel bioelectronics are provided at the end of the review.
Collapse
Affiliation(s)
- Shengnan Li
- Key Laboratory of Polymeric Composite and Functional Materials of Ministry of Education, Guangdong Functional Biomaterials Engineering Technology Research Center, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, School of Materials Science and Engineering, Sun Yat-sen University, 135 Xingang Road West, Guangzhou 510275, China.
| | - Yang Cong
- College of Materials Science and Chemical Engineering, Ningbo University of Technology, Ningbo 315201, China
| | - Jun Fu
- Key Laboratory of Polymeric Composite and Functional Materials of Ministry of Education, Guangdong Functional Biomaterials Engineering Technology Research Center, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, School of Materials Science and Engineering, Sun Yat-sen University, 135 Xingang Road West, Guangzhou 510275, China.
| |
Collapse
|
44
|
Ma Z, Bao G, Li J. Multifaceted Design and Emerging Applications of Tissue Adhesives. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2007663. [PMID: 33956371 DOI: 10.1002/adma.202007663] [Citation(s) in RCA: 86] [Impact Index Per Article: 28.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 12/04/2020] [Indexed: 05/24/2023]
Abstract
Tissue adhesives can form appreciable adhesion with tissues and have found clinical use in a variety of medical settings such as wound closure, surgical sealants, regenerative medicine, and device attachment. The advantages of tissue adhesives include ease of implementation, rapid application, mitigation of tissue damage, and compatibility with minimally invasive procedures. The field of tissue adhesives is rapidly evolving, leading to tissue adhesives with superior mechanical properties and advanced functionality. Such adhesives enable new applications ranging from mobile health to cancer treatment. To provide guidelines for the rational design of tissue adhesives, here, existing strategies for tissue adhesives are synthesized into a multifaceted design, which comprises three design elements: the tissue, the adhesive surface, and the adhesive matrix. The mechanical, chemical, and biological considerations associated with each design element are reviewed. Throughout the report, the limitations of existing tissue adhesives and immediate opportunities for improvement are discussed. The recent progress of tissue adhesives in topical and implantable applications is highlighted, and then future directions toward next-generation tissue adhesives are outlined. The development of tissue adhesives will fuse disciplines and make broad impacts in engineering and medicine.
Collapse
Affiliation(s)
- Zhenwei Ma
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
| | - Guangyu Bao
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
| | - Jianyu Li
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
- Department of Biomedical Engineering, McGill University, Montréal, QC, H3A 2B4, Canada
| |
Collapse
|
45
|
Abdel-Haq M, Alyan R, Abd-Rbo K, Kasem H, Abu Ammar A. Biomimetic clotrimazole-loaded PLGA films with enhanced adhesiveness for controlled drug release. Int J Pharm 2021; 601:120578. [PMID: 33839222 DOI: 10.1016/j.ijpharm.2021.120578] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 03/20/2021] [Accepted: 04/04/2021] [Indexed: 10/21/2022]
Abstract
Biomimetic adhesive surfaces have a number of potential applications in the pharmaceutical and biomedical fields. Fabrication techniques must be adapted to biocompatible and biodegradable materials required for controlled drug release applications. In this study biomimetic adhesive poly(lactic-co-glycolic acid) (PLGA) films loaded with different concentrations of clotrimazole (CTZ) were prepared without combining other adhesive excipients as a controlled release system for potential local oral drug delivery. The films were fully characterized from morphological point of view, and CTZ-loaded biomimetic films exhibited adequate surface pH values, high drug encapsulation efficiency, and loading content. The adhesion strength of the obtained films was significantly higher compared to a flat film reference under different contact conditions. Thermal analysis indicated a decrease of drug crystallinity upon incorporation into PLGA films. The in vitro release of CTZ from PLGA biomimetic films was tested in simulated saliva, and it exhibited an initial burst release, accompanied by a sustained release phase over 10 days. Finally, the mucoadhesive properties of the obtained films was studied using agar/mucin plate as a representative mucosal substrate, and the results demonstrated superior mucoadhesion potential of CTZ-loaded biomimetic film in comparison to its flat counterpart. Having demonstrated the ability to load CTZ into PLGA biomimetic films with enhanced adhesion capacity, the potential use in local oral drug delivery applications warrants further in vitro and in vivo investigations.
Collapse
Affiliation(s)
- Muhammad Abdel-Haq
- Department of Pharmaceutical Engineering, Azrieli College of Engineering, Jerusalem, Jerusalem 9103501, Israel
| | - Rayan Alyan
- Department of Pharmaceutical Engineering, Azrieli College of Engineering, Jerusalem, Jerusalem 9103501, Israel
| | - Kareem Abd-Rbo
- Department of Mechanical Engineering, Azrieli College of Engineering Jerusalem, Jerusalem 9103501, Israel
| | - Haytam Kasem
- Department of Mechanical Engineering, Azrieli College of Engineering Jerusalem, Jerusalem 9103501, Israel
| | - Aiman Abu Ammar
- Department of Pharmaceutical Engineering, Azrieli College of Engineering, Jerusalem, Jerusalem 9103501, Israel.
| |
Collapse
|
46
|
Jiao Y, Chu L, Zhu M, Wei Y, Wang W, Wang H, Wang H. UV-curable hyperbranched polyester sealant with tunable mechanical properties. J Biomater Appl 2021; 36:731-739. [PMID: 33940972 DOI: 10.1177/08853282211000527] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Different types of wounds have different requirements of a wound sealant. One of the requirements of concern is the adaptability of the mechanical properties of biomaterials to native tissues. However, the mechanical properties of current sealant are untunable or adjustable in a small range normally. Therefore, the scope of application of these sealant is limited. In this study, we developed hyperbranched polyester (HBP)-based UV-curable sealant with tunable mechanical properties. This sealant was cured under UV-light for 2 minutes and exhibited strong adhesion with tissues. The shear adhesive strength of it to the porcine skin ranged between 20-30 kPa, which was higher than the fibrin glue (∼10 kPa). Moreover, the elastic modulus of the sealant in a tensile test ranged between 27-54 MPa, depending on the degree of acrylation of the HBPs. Additionally, we assessed the biocompatibility of the sealant by co-culturing it with mouse mesenchymal stem cells (mMSCs) for 7 days and discovered that the cell viability was unaffected. This sealant with a tunable elastic modulus might be a promising candidate for treating wounds with different elastic moduli.
Collapse
Affiliation(s)
- Yan Jiao
- Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital of Sun Yat-sen University-Guangzhou, China.,Medical Device Management Branch of Guangdong Primary Medicine Association, Guangzhou, China
| | - Lili Chu
- Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital of Sun Yat-sen University-Guangzhou, China.,Department of Colorectal Surgery, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Miaomiao Zhu
- Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital of Sun Yat-sen University-Guangzhou, China.,Department of Colorectal Surgery, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Yingqi Wei
- Department of Colorectal Surgery, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Institute of Gastroenterology, Guangzhou, China
| | - Weicai Wang
- Department of Colorectal Surgery, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.,Guangdong Institute of Gastroenterology, Guangzhou, China
| | - Huaiming Wang
- Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital of Sun Yat-sen University-Guangzhou, China.,Department of Colorectal Surgery, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Hui Wang
- Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital of Sun Yat-sen University-Guangzhou, China.,Department of Colorectal Surgery, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
47
|
|
48
|
Wang Y, Chen G, Zhang H, Zhao C, Sun L, Zhao Y. Emerging Functional Biomaterials as Medical Patches. ACS NANO 2021; 15:5977-6007. [PMID: 33856205 DOI: 10.1021/acsnano.0c10724] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Medical patches have been widely explored and applied in various medical fields, especially in wound healing, tissue engineering, and other biomedical areas. Benefiting from emerging biomaterials and advanced manufacturing technologies, great achievements have been made on medical patches to evolve them into a multifunctional medical device for diverse health-care purposes, thus attracting extensive attention and research interest. Here, we provide up-to-date research concerning emerging functional biomaterials as medical patches. An overview of the various approaches to construct patches with micro- and nanoarchitecture is presented and summarized. We then focus on the applications, especially the biomedical applications, of the medical patches, including wound healing, drug delivery, and real-time health monitoring. The challenges and prospects for the future development of the medical patches are also discussed.
Collapse
Affiliation(s)
- Yu Wang
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, 210008 Nanjing, China
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Guopu Chen
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, 210008 Nanjing, China
| | - Han Zhang
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Cheng Zhao
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, 210008 Nanjing, China
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Lingyun Sun
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, 210008 Nanjing, China
| | - Yuanjin Zhao
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, 210008 Nanjing, China
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
49
|
Haverkamp CB, Hwang D, Lee C, Bartlett MD. Deterministic control of adhesive crack propagation through jamming based switchable adhesives. SOFT MATTER 2021; 17:1731-1737. [PMID: 33491725 DOI: 10.1039/d0sm02129f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Controlling delamination across a material interface is a foundation of adhesive science and technology. This ranges from creating permanent, strong adhesives which limit crack propagation to reversible adhesives which initiate cracks for release. Methods which dynamically control cracks can lead to more robust adhesion, however specific control of crack initiation, propagation, and arresting is challenging because time scales of crack propagation are much faster than times scales of mechanisms to arrest cracks. Here we show the deterministic control of crack initiation, propagation, and arresting by integrating a granular jamming layer into adhesive films. This allows for controlled initiation of a propagating crack by reducing rigidity and then rapidly arresting the crack through jamming, with a rise in stiffness and an 11× enhancement in adhesion. This process is highly reversible and programmable, allowing for numerous crack initiation, propagation, and arresting cycles at arbitrary selectable locations in a peeling adhesive. We demonstrate this crack-control approach in single and multiple peel directions under fixed load conditions in response to diverse pressurization input signal profiles (i.e. time varying propagation and arresting scenarios).
Collapse
Affiliation(s)
- Cole B Haverkamp
- Department of Materials Science & Engineering, Iowa State University, Ames, IA 50011, USA
| | - Dohgyu Hwang
- Macromolecules Innovation Institute, Virginia Tech, Blacksburg, VA 24061, USA. and Department of Mechanical Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, VA 24061, USA
| | - Chanhong Lee
- Department of Materials Science & Engineering, Iowa State University, Ames, IA 50011, USA
| | - Michael D Bartlett
- Macromolecules Innovation Institute, Virginia Tech, Blacksburg, VA 24061, USA. and Department of Mechanical Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, VA 24061, USA
| |
Collapse
|
50
|
Baik S, Hwang GW, Jang S, Jeong S, Kim KH, Yang TH, Pang C. Bioinspired Microsphere-Embedded Adhesive Architectures for an Electrothermally Actuating Transport Device of Dry/Wet Pliable Surfaces. ACS APPLIED MATERIALS & INTERFACES 2021; 13:6930-6940. [PMID: 33523645 DOI: 10.1021/acsami.0c21847] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
For highly conformable and universal transport devices, bioinspired dry adhesion systems with reversible molecular attractions (e.g., van der Waals forces, capillarity, or suction stress) between the engaged surfaces have recently become favorable for various dry/wet processes in flexible devices and medical applications. In addition, many efforts have been made for switchable attachments of such adhesives by employing costly sophisticated systems such as mechanically deformable chucks, UV-radiating components, or fluidic channels. In this work, we propose a simple electrothermally actuating transport device based on an octopus-inspired microsphere-embedded sucker (OMS). The adhesive with microsphere-embedded suckers offers enhanced adhesion on dry/wet surfaces, in accordance with investigation of the geometric and materials parameters of the novel suction architecture for maximizing adhesion interactions. Inspired by muscle actuation of octopus tentacles, we laminate the electrothermally reactive poly(3,4-ethylenedioxy thiophene):poly(styrenesulfonic acid) (PEDOT:PSS) layer on the backside of the OMS adhesive patch. By controlling inputs of electrical energy, our assembled actuator may actively expand and contract reversibly to induce switchable attachments and detachments. Our bioinspired device can be integrated onto a robotic arm to attach and release against dry/wet flexible thin objects.
Collapse
Affiliation(s)
- Sangyul Baik
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, Gyeonggi-do 16419, Republic of Korea
| | - Gui Won Hwang
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, Gyeonggi-do 16419, Republic of Korea
| | - Siyeon Jang
- SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Republic of Korea
| | - Suyeon Jeong
- SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Republic of Korea
| | - Ki Hyun Kim
- School of Pharmacy, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Republic of Korea
| | - Tae-Heon Yang
- Department of Electronic Engineering, Korea National University of Transportation, Chungju 27469, Republic of Korea
| | - Changhyun Pang
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, Gyeonggi-do 16419, Republic of Korea
| |
Collapse
|