1
|
Paul Robinson J, Rajwa B. Spectral flow cytometry: Fundamentals and future impact. Methods Cell Biol 2024; 186:311-332. [PMID: 38705605 DOI: 10.1016/bs.mcb.2024.02.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/07/2024]
Abstract
Spectral flow cytometry has emerged as a significant player in the cytometry marketplace, with the potential for rapid growth. Despite a slow start, the technology has made significant strides in advancing various areas of single-cell analysis utilized by the scientific community. The integration of spectral cytometry into clinical laboratories and diagnostic processes is currently underway and is expected to garner a significant level of widespread acceptance in the near future. However, incorporating a new methodological approach into existing research programs can lead to misunderstandings or even misuse. This chapter offers an introductory yet comprehensive explanation of the scientific principles that form the foundation of spectral cytometry. Specifically, it delves into the unmixing processes that are utilized for data analysis. This overview is designed for those who are new to the field and seeking an informative guide to this exciting emerging technology.
Collapse
Affiliation(s)
- J Paul Robinson
- Weldon School of Biomedical Engineering, College of Engineering, Purdue University, West Lafayette, IN, United States; Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United States.
| | - Bartek Rajwa
- Bindley Bioscience Center, Purdue University, West Lafayette, IN, United States
| |
Collapse
|
2
|
Nißler R, Totter E, Walter SG, Metternich JT, Cipolato O, Nowack D, Gogos A, Herrmann IK. Material-Intrinsic NIR-Fluorescence Enables Image-Guided Surgery for Ceramic Fracture Removal. Adv Healthc Mater 2024; 13:e2302950. [PMID: 38245823 DOI: 10.1002/adhm.202302950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 01/10/2024] [Indexed: 01/22/2024]
Abstract
Hip arthroplasty effectively treats advanced osteoarthritis and is therefore entitled as "operation of the 20th century." With demographic shifts, the USA alone is projected to perform up to 850 000 arthroplasties annually by 2030. Many implants now feature a ceramic head, valued for strength and wear resistance. Nonetheless, a fraction, up to 0.03% may fracture during their lifespan, demanding complex removal procedures. To address this, a radiation-free, fluorescence-based image-guided surgical technique is presented. The method uses the inherent fluorescence of ceramic implant materials, demonstrated through chemical and optical analysis of prevalent implant types. Specifically, Biolox delta implants exhibited strong fluorescence around 700 nm with a 74% photoluminescence quantum yield. Emission tails are identified extending into the near-infrared (NIR-I) biological transparency range, forming a vital prerequisite for the label-free visualization of fragments. This ruby-like fluorescence could be attributed to Cr within the zirconia-toughened alumina matrix, enabling the detection of even deep-seated millimeter-sized fragments via camera-assisted techniques. Additionally, fluorescence microscopy allowed detection of µm-sized ceramic particles, enabling debris visualization in synovial fluid as well as histological samples. This label-free optical imaging approach employs readily accessible equipment and can seamlessly transition to clinical settings without significant regulatory barriers, thereby enhancing the safety, efficiency, and minimally invasive nature of fractured ceramic implant removal procedures.
Collapse
Affiliation(s)
- Robert Nißler
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
- Particles-Biology Interactions, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, St. Gallen, 9014, Switzerland
- The Ingenuity Lab, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland
| | - Elena Totter
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
| | - Sebastian G Walter
- Department of Orthopedics, Traumatology and Reconstructive Surgery, University Hospital Cologne, Joseph-Stelzmann-Str. 24, 50931, Cologne, Germany
| | - Justus T Metternich
- Physical Chemistry, Ruhr-University Bochum, Universitätsstr. 150, 44801, Bochum, Germany
- Fraunhofer Institute for Microelectronic Circuits and Systems (IMS), Finkenstr. 61, 47057, Duisburg, Germany
| | - Oscar Cipolato
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
- Particles-Biology Interactions, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, St. Gallen, 9014, Switzerland
- The Ingenuity Lab, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland
| | - Dimitri Nowack
- Deutsches Zentrum für Orthopädie, Department of Orthopedics and Trauma Surgery, Friedrich Schiller University Jena, Eisenberg, 07743, Jena, Germany
| | - Alexander Gogos
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
- Particles-Biology Interactions, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, St. Gallen, 9014, Switzerland
| | - Inge K Herrmann
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
- Particles-Biology Interactions, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, St. Gallen, 9014, Switzerland
- The Ingenuity Lab, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland
| |
Collapse
|
3
|
Robinson JP, Ostafe R, Iyengar SN, Rajwa B, Fischer R. Flow Cytometry: The Next Revolution. Cells 2023; 12:1875. [PMID: 37508539 PMCID: PMC10378642 DOI: 10.3390/cells12141875] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/06/2023] [Accepted: 07/13/2023] [Indexed: 07/30/2023] Open
Abstract
Unmasking the subtleties of the immune system requires both a comprehensive knowledge base and the ability to interrogate that system with intimate sensitivity. That task, to a considerable extent, has been handled by an iterative expansion in flow cytometry methods, both in technological capability and also in accompanying advances in informatics. As the field of fluorescence-based cytomics matured, it reached a technological barrier at around 30 parameter analyses, which stalled the field until spectral flow cytometry created a fundamental transformation that will likely lead to the potential of 100 simultaneous parameter analyses within a few years. The simultaneous advance in informatics has now become a watershed moment for the field as it competes with mature systematic approaches such as genomics and proteomics, allowing cytomics to take a seat at the multi-omics table. In addition, recent technological advances try to combine the speed of flow systems with other detection methods, in addition to fluorescence alone, which will make flow-based instruments even more indispensable in any biological laboratory. This paper outlines current approaches in cell analysis and detection methods, discusses traditional and microfluidic sorting approaches as well as next-generation instruments, and provides an early look at future opportunities that are likely to arise.
Collapse
Affiliation(s)
- J Paul Robinson
- Department of Basic Medical Sciences, Purdue University, West Lafayette, IN 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Raluca Ostafe
- Molecular Evolution, Protein Engineering and Production Facility (PI4D), Purdue University, West Lafayette, IN 47907, USA
| | | | - Bartek Rajwa
- Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907, USA
| | - Rainer Fischer
- Department of Comparative Pathobiology, College of Veterinary Medicine, Purdue University, West Lafayette, IN 47907, USA
- Purdue Institute of Inflammation, Immunology and Infectious Diseases, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
4
|
Li L, Wang S, Xue J, Lin Y, Su L, Xue C, Mao C, Cai N, Tian Y, Zhu S, Wu L, Yan X. Development of Spectral Nano-Flow Cytometry for High-Throughput Multiparameter Analysis of Individual Biological Nanoparticles. Anal Chem 2023; 95:3423-3433. [PMID: 36735936 DOI: 10.1021/acs.analchem.2c05159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Correlated analysis of multiple biochemical parameters at the single-particle level and in a high-throughput manner is essential for insights into the diversity and functions of biological nanoparticles (BNPs), such as bacteria and subcellular organelles. To meet this challenge, we developed a highly sensitive spectral nano-flow cytometer (S-nFCM) by integrating a spectral recording module to a laboratory-built nFCM that is 4-6 orders of magnitude more sensitive in side scattering detection and 1-2 orders of magnitude more sensitive in fluorescence detection than conventional flow cytometers. An electron-multiplying charge-coupled device (EMCCD) was used to acquire the full fluorescence spectra of single BNPs upon holographic grating dispersion. Up to 10,000 spectra can be collected in 1 min with 2.1 nm resolution. The precision, linearity, and sensitivity were examined. Complete discernment of single influenza viruses against the background signal, discrimination of different strains of marine cyanobacteria in a mixed sample based on their spectral properties of natural fluorescence, classification of bacterial categories exhibiting different patterns of antigen expression, and multiparameter analysis of single mitochondria for drug discovery were successfully demonstrated.
Collapse
Affiliation(s)
- Lihong Li
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Shuo Wang
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Junwei Xue
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Yao Lin
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Liyun Su
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Chengfeng Xue
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Cuiping Mao
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Niangui Cai
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Ye Tian
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Shaobin Zhu
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Lina Wu
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Xiaomei Yan
- Department of Chemical Biology, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
5
|
Vorobjev IA, Kussanova A, Barteneva NS. Development of Spectral Imaging Cytometry. Methods Mol Biol 2023; 2635:3-22. [PMID: 37074654 DOI: 10.1007/978-1-0716-3020-4_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
Spectral flow cytometry is a new technology that enables measurements of fluorescent spectra and light scattering properties in diverse cellular populations with high precision. Modern instruments allow simultaneous determination of up to 40+ fluorescent dyes with heavily overlapping emission spectra, discrimination of autofluorescent signals in the stained specimens, and detailed analysis of diverse autofluorescence of different cells-from mammalian to chlorophyll-containing cells like cyanobacteria. In this paper, we review the history, compare modern conventional and spectral flow cytometers, and discuss several applications of spectral flow cytometry.
Collapse
Affiliation(s)
- Ivan A Vorobjev
- School of Sciences and Humanities, Nazarbayev University, Astana, Kazakhstan.
- National Laboratory Astana, Nazarbayev University, Astana, Kazakhstan.
- A.N. Belozersky Insitute of Physico-Chemical Biology, Lomonosov Moscow State University, Moscow, Russian Federation.
- Biological Faculty, Lomonosov Moscow State University, Moscow, Russian Federation.
| | - Aigul Kussanova
- School of Sciences and Humanities, Nazarbayev University, Astana, Kazakhstan
- Core Facilities, Nazarbayev University, Astana, Kazakhstan
| | - Natasha S Barteneva
- School of Sciences and Humanities, Nazarbayev University, Astana, Kazakhstan
- Brigham Women's Hospital, Harvard University, Boston, MA, USA
| |
Collapse
|
6
|
Zhang T, Gao M, Chen X, Gao C, Feng S, Chen D, Wang J, Zhao X, Chen J. Demands and technical developments of clinical flow cytometry with emphasis in quantitative, spectral, and imaging capabilities. NANOTECHNOLOGY AND PRECISION ENGINEERING 2022. [DOI: 10.1063/10.0015301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
As the gold-standard method for single-cell analysis, flow cytometry enables high-throughput and multiple-parameter characterization of individual biological cells. This review highlights the demands for clinical flow cytometry in laboratory hematology (e.g., diagnoses of minimal residual disease and various types of leukemia), summarizes state-of-the-art clinical flow cytometers (e.g., FACSLyricTM by Becton Dickinson, DxFLEX by Beckman Coulter), then considers innovative technical improvements in flow cytometry (including quantitative, spectral, and imaging approaches) to address the limitations of clinical flow cytometry in hematology diagnosis. Finally, driven by these clinical demands, future developments in clinical flow cytometry are suggested.
Collapse
Affiliation(s)
- Ting Zhang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Mengge Gao
- Peking University People’s Hospital, Peking University Institute of Hematology, National Clinical Research Center for Hematologic Disease, Beijing Key Laboratory of Hematopoietic Stem Cell Transplantation, Beijing 100044, People’s Republic of China
| | - Xiao Chen
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Chiyuan Gao
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Shilun Feng
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, People’s Republic of China
| | - Deyong Chen
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Junbo Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Xiaosu Zhao
- Peking University People’s Hospital, Peking University Institute of Hematology, National Clinical Research Center for Hematologic Disease, Beijing Key Laboratory of Hematopoietic Stem Cell Transplantation, Beijing 100044, People’s Republic of China
| | - Jian Chen
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, People’s Republic of China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| |
Collapse
|
7
|
Novo D. A comparison of spectral unmixing to conventional compensation for the calculation of fluorochrome abundances from flow cytometric data. Cytometry A 2022; 101:885-891. [PMID: 35841160 DOI: 10.1002/cyto.a.24669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 06/28/2022] [Accepted: 07/04/2022] [Indexed: 01/27/2023]
Abstract
Traditionally, flow cytometers acquired data using the same number of detectors as fluorochromes being measured in the experiment. More recently, spectral flow cytometers utilize a larger number of detectors than fluorochromes. This seemingly small difference opens the door to a wide variety of mathematical tools for the calculation of the true fluorochrome abundances from the raw detector values as compared with traditional compensation. This review will provide a brief overview of the mathematics and theory underlying traditional compensation and unmixing focusing on the differences between them and the additional information provided by unmixing approaches.
Collapse
Affiliation(s)
- David Novo
- De Novo Software, Pasadena, California, USA
| |
Collapse
|
8
|
Dannenberg PH, Kang J, Martino N, Kashiparekh A, Forward S, Wu J, Liapis AC, Wang J, Yun SH. Laser particle activated cell sorting in microfluidics. LAB ON A CHIP 2022; 22:2343-2351. [PMID: 35621381 PMCID: PMC9195882 DOI: 10.1039/d2lc00235c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 04/22/2022] [Indexed: 05/30/2023]
Abstract
Laser particles providing bright, spectrally narrowband emission renders them suitable for use as cellular barcodes. Here, we demonstrate a microfluidic platform integrated with a high-speed spectrometer, capable of reading the emission from laser particles in fluidic channels and routing cells based on their optical barcodes. The sub-nanometer spectral emission of each laser particle enables us to distinguish individual cells labeled with hundreds of different laser colors in the near infrared. Furthermore, cells tagged with laser particles are sorted based on their spectral barcodes at a kilohertz rate by using a real-time field programmable gate array and 2-way electric field switch. We demonstrate several different flavors of sorting, including isolation of barcoded cells, and cells tagged with a specific laser color. We term this novel sorting technique laser particle activated cell sorting (LACS). This flow reading and sorting technology adds to the arsenal of single-cell analysis tools using laser particles.
Collapse
Affiliation(s)
- Paul H Dannenberg
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard Medical School, Boston, MA 02115, USA.
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jisoo Kang
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Nicola Martino
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard Medical School, Boston, MA 02115, USA.
| | - Anokhi Kashiparekh
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Sarah Forward
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Jiamin Wu
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Department of Automation, Tsinghua University, Beijing, China
| | - Andreas C Liapis
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard Medical School, Boston, MA 02115, USA.
| | - Jie Wang
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- College of Artificial Intelligence, Nanjing Agricultural University, Nanjing, Jiangsu 210031, China
| | - Seok-Hyun Yun
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard Medical School, Boston, MA 02115, USA.
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
9
|
Caligola S, De Sanctis F, Canè S, Ugel S. Breaking the Immune Complexity of the Tumor Microenvironment Using Single-Cell Technologies. Front Genet 2022; 13:867880. [PMID: 35651929 PMCID: PMC9149246 DOI: 10.3389/fgene.2022.867880] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 04/27/2022] [Indexed: 12/31/2022] Open
Abstract
Tumors are not a simple aggregate of transformed cells but rather a complicated ecosystem containing various components, including infiltrating immune cells, tumor-related stromal cells, endothelial cells, soluble factors, and extracellular matrix proteins. Profiling the immune contexture of this intricate framework is now mandatory to develop more effective cancer therapies and precise immunotherapeutic approaches by identifying exact targets or predictive biomarkers, respectively. Conventional technologies are limited in reaching this goal because they lack high resolution. Recent developments in single-cell technologies, such as single-cell RNA transcriptomics, mass cytometry, and multiparameter immunofluorescence, have revolutionized the cancer immunology field, capturing the heterogeneity of tumor-infiltrating immune cells and the dynamic complexity of tenets that regulate cell networks in the tumor microenvironment. In this review, we describe some of the current single-cell technologies and computational techniques applied for immune-profiling the cancer landscape and discuss future directions of how integrating multi-omics data can guide a new "precision oncology" advancement.
Collapse
Affiliation(s)
- Simone Caligola
- Immunology Section, Department of Medicine, University of Verona, Verona, Italy
| | | | - Stefania Canè
- Immunology Section, Department of Medicine, University of Verona, Verona, Italy
| | - Stefano Ugel
- Immunology Section, Department of Medicine, University of Verona, Verona, Italy
| |
Collapse
|
10
|
Rodriguez-Esteban R, Duarte J, Teixeira PC, Richard F, Koltsova S, So WV. Prediction of standard cell types and functional markers from textual descriptions of flow cytometry gating definitions using machine learning. CYTOMETRY. PART B, CLINICAL CYTOMETRY 2022; 102:220-227. [PMID: 35253974 DOI: 10.1002/cyto.b.22065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 02/02/2022] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND A key step in clinical flow cytometry data analysis is gating, which involves the identification of cell populations. The process of gating produces a set of reportable results, which are typically described by gating definitions. The non-standardized, non-interpreted nature of gating definitions represents a hurdle for data interpretation and data sharing across and within organizations. Interpreting and standardizing gating definitions for subsequent analysis of gating results requires a curation effort from experts. Machine learning approaches have the potential to help in this process by predicting expert annotations associated with gating definitions. METHODS We created a gold-standard dataset by manually annotating thousands of gating definitions with cell type and functional marker annotations. We used this dataset to train and test a machine learning pipeline able to predict standard cell types and functional marker genes associated with gating definitions. RESULTS The machine learning pipeline predicted annotations with high accuracy for both cell types and functional marker genes. Accuracy was lower for gating definitions from assays belonging to laboratories from which limited or no prior data was available in the training. Manual error review ensured that resulting predicted annotations could be reused subsequently as additional gold-standard training data. CONCLUSIONS Machine learning methods are able to consistently predict annotations associated with gating definitions from flow cytometry assays. However, a hybrid automatic and manual annotation workflow would be recommended to achieve optimal results.
Collapse
Affiliation(s)
- Raul Rodriguez-Esteban
- Roche Pharmaceutical Research and Early Development, Roche Innovation Center Basel, Basel, Switzerland
| | - José Duarte
- Roche Pharmaceutical Research and Early Development, Roche Innovation Center Basel, Basel, Switzerland
| | - Priscila C Teixeira
- Roche Pharmaceutical Research and Early Development, Roche Innovation Center Basel, Basel, Switzerland
| | - Fabien Richard
- Roche Pharmaceutical Research and Early Development, Roche Innovation Center Basel, Basel, Switzerland
| | - Svetlana Koltsova
- Curation Department, Rancho BioSciences LLC, San Diego, California, USA
| | - W Venus So
- Roche Pharmaceutical Research and Early Development, Roche Innovation Center New York, New York, USA
| |
Collapse
|
11
|
Ferrer-Font L, Pellefigues C, Mayer JU, Small SJ, Jaimes MC, Price KM. Panel Design and Optimization for High-Dimensional Immunophenotyping Assays Using Spectral Flow Cytometry. ACTA ACUST UNITED AC 2021; 92:e70. [PMID: 32150355 DOI: 10.1002/cpcy.70] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Technological advances in fluorescence flow cytometry and an ever-expanding understanding of the complexity of the immune system have led to the development of large (20+ parameters) flow cytometry panels. However, as panel complexity and size increase, so does the difficulty involved in designing a high-quality panel, accessing the instrumentation capable of accommodating large numbers of parameters, and analyzing such high-dimensional data. A recent advancement is spectral flow cytometry, which in contrast to conventional flow cytometry distinguishes the full emission spectrum of each fluorophore across all lasers, rather than identifying only the peak of emission. Fluorophores with a similar emission maximum but distinct off-peak signatures can therefore be accommodated within the same flow cytometry panel, allowing greater flexibility in terms of panel design and fluorophore detection. Here, we highlight the specific characteristics of spectral flow cytometry and aim to guide users through the process of building, designing, and optimizing high-dimensional spectral flow cytometry panels using a comprehensive step-by-step protocol. Special considerations are also given for using highly overlapping dyes, and a logical selection process for optimal marker-fluorophore assignment is provided. © 2020 by John Wiley & Sons, Inc.
Collapse
Affiliation(s)
| | | | | | - Sam J Small
- Malaghan Institute of Medical Research, Wellington, New Zealand
| | | | - Kylie M Price
- Malaghan Institute of Medical Research, Wellington, New Zealand
| |
Collapse
|
12
|
Riggs JB, Medina EM, Perrenoud LJ, Bonilla DL, Clambey ET, van Dyk LF, Berg LJ. Optimized Detection of Acute MHV68 Infection With a Reporter System Identifies Large Peritoneal Macrophages as a Dominant Target of Primary Infection. Front Microbiol 2021; 12:656979. [PMID: 33767688 PMCID: PMC7985543 DOI: 10.3389/fmicb.2021.656979] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 02/15/2021] [Indexed: 11/13/2022] Open
Abstract
Investigating the dynamics of virus-host interactions in vivo remains an important challenge, often limited by the ability to directly identify virally infected cells. Here, we utilize a beta-lactamase activated fluorescent substrate to identify primary targets of murine gammaherpesvirus 68 (MHV68) infection in the peritoneal cavity. By optimizing substrate and detection conditions, we were able to achieve multiparameter characterization of infected cells and the ensuing host response. MHV68 infection leads to a pronounced increase in immune cells, with CD8+ T cells increasing by 3 days, and total infiltrate peaking around 8 days post-infection. MHV68 infection results in near elimination of large peritoneal macrophages (LPMs) by 8 days post-infection, and a concordant increase in small peritoneal macrophages (SPMs) and monocytes. Infection is associated with prolonged changes to myeloid cells, with a distinct population of MHC IIhigh LPMs emerging by 14 days. Targets of MHV68 infection could be readily detected. Between 1 and 3 days post-infection, MHV68 infects ∼5–10% of peritoneal cells, with >75% being LPMs. By 8 days post-infection, the frequency of MHV68 infection is reduced at least 10-fold, with infection primarily in SPMs, with few infected dendritic cells and B cells. Importantly, limiting dilution analysis indicates that at 3 days post-infection, the majority of MHV68-infected cells harbor latent rather than lytic virus at frequencies consistent with those identified based on reporter gene expression. Our findings demonstrate the utility of the beta-lactamase MHV68 reporter system for high throughput single-cell analysis and identify dynamic changes during primary gammaherpesvirus infection.
Collapse
Affiliation(s)
- Julianne B Riggs
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| | - Eva M Medina
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| | - Loni J Perrenoud
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| | | | - Eric T Clambey
- Department of Anesthesiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| | - Linda F van Dyk
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| | - Leslie J Berg
- Department of Immunology and Microbiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| |
Collapse
|
13
|
Bonilla DL, Reinin G, Chua E. Full Spectrum Flow Cytometry as a Powerful Technology for Cancer Immunotherapy Research. Front Mol Biosci 2021; 7:612801. [PMID: 33585561 PMCID: PMC7878389 DOI: 10.3389/fmolb.2020.612801] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 12/18/2020] [Indexed: 12/12/2022] Open
Abstract
The Nobel Prize-deserving concept of blocking inhibitory pathways in T cells, to unleash their anti-tumoral capacity, became one of the pillars of cancer treatment in the last decade and has resulted in durable clinical responses for multiple cancer types. Currently, two of the most important goals in cancer immunotherapy are to understand the mechanisms resulting in failure to checkpoint blockade and to identify predictive immunological biomarkers that correlate to treatment response, disease progression or adverse effects. The identification and validation of biomarkers for routine clinical use is not only critical to monitor disease or treatment progression, but also to personalize and develop new therapies. To achieve these goals, powerful research tools are needed. Flow cytometry stands as one of the most successful single-cell analytical tools used to characterize immune cell phenotypes to monitor solid tumors, hematological malignancies, minimal residual disease or metastatic progression. This technology has been fundamental in diagnosis, treatment and translational research in cancer clinical trials. Most recently, the need to evaluate simultaneously more features in each cell has pushed the field to implement more powerful adaptations beyond conventional flow cytometry, including Full Spectrum Flow Cytometry (FSFC). FSFC captures the full emission spectrum of fluorescent molecules using arrays of highly sensitive light detectors, and to date has enabled characterization of 40 parameters in a single sample. We will summarize the contributions of this technology to the advancement of research in immunotherapy studies and discuss best practices to obtain reliable, robust and reproducible FSFC results.
Collapse
|
14
|
Niewold P, Ashhurst TM, Smith AL, King NJC. Evaluating spectral cytometry for immune profiling in viral disease. Cytometry A 2020; 97:1165-1179. [PMID: 32799382 DOI: 10.1002/cyto.a.24211] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 06/23/2020] [Accepted: 06/25/2020] [Indexed: 01/02/2023]
Abstract
In conventional fluorescence cytometry, each fluorophore present in a panel is measured in a target detector, through the use of wide band-pass optical filters. In contrast, spectral cytometry uses a large number of detectors with narrow band-pass filters to measure a fluorophore's signal across the spectrum, creating a more detailed fluorescent signature for each fluorophore. The spectral approach shows promise in adding flexibility to panel design and improving the measurement of fluorescent signal. However, few comparisons between conventional and spectral systems have been reported to date. We therefore sought to compare a modern conventional cytometry system with a modern spectral system, and to assess the quality of resulting datasets from the point of view of a flow cytometry user. Signal intensity, spread, and resolution were compared between the systems. Subsequently, the different methods of separating fluorophore signals were compared, where compensation mathematically separates multiple overlapping fluorophores and unmixing relies on creating a detailed fluorescent signature across the spectrum to separate the fluorophores. Within the spectral data set, signal spread and resolution were comparable between compensation and unmixing. However, for some highly overlapping fluorophores, unmixing resolved the two fluorescence signals where compensation did not. Finally, data from mid- to large-size panels were acquired and were found to have comparable resolution for many fluorophores on both instruments, but reduced levels of spreading error on our spectral system improved signal resolution for a number of fluorophores, compared with our conventional system. Furthermore, autofluorescence extraction on the spectral system allowed for greater population resolution in highly autofluorescent samples. Overall, the implementation of a spectral cytometry approach resulted in data that are comparable to that generated on conventional systems, with a number of potential advantages afforded by the larger number of detectors, and the integration of the spectral unmixing approach. © 2020 International Society for Advancement of Cytometry.
Collapse
Affiliation(s)
- Paula Niewold
- Discipline of Pathology, Charles Perkins Centre, The Faculty of Medicine and Health, Camperdown, New South Wales, Australia
| | - Thomas Myles Ashhurst
- Sydney Cytometry Core Research Facility, Charles Perkins Centre, The Centenary Institute and The University of Sydney, Johns Hopkins Drive, Camperdown, New South Wales, Australia
| | - Adrian Lloyd Smith
- Sydney Cytometry Core Research Facility, Charles Perkins Centre, The Centenary Institute and The University of Sydney, Johns Hopkins Drive, Camperdown, New South Wales, Australia
| | - Nicholas Jonathan Cole King
- Discipline of Pathology, Charles Perkins Centre, The Faculty of Medicine and Health, Camperdown, New South Wales, Australia.,Sydney Cytometry Core Research Facility, Charles Perkins Centre, The Centenary Institute and The University of Sydney, Johns Hopkins Drive, Camperdown, New South Wales, Australia
| |
Collapse
|
15
|
Hoffmann K, Nirmalananthan-Budau N, Resch-Genger U. Fluorescence calibration standards made from broadband emitters encapsulated in polymer beads for fluorescence microscopy and flow cytometry. Anal Bioanal Chem 2020; 412:6499-6507. [PMID: 32409890 PMCID: PMC7442758 DOI: 10.1007/s00216-020-02664-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Revised: 03/31/2020] [Accepted: 04/15/2020] [Indexed: 01/31/2023]
Abstract
We present here the design and characterization of a set of spectral calibration beads. These calibration beads are intended for the determination and regular control of the spectral characteristics of fluorescence microscopes and other fluorescence measuring devices for the readout of bead-based assays. This set consists of micrometer-sized polymer beads loaded with dyes from the liquid Calibration Kit Spectral Fluorescence Standards developed and certified by BAM for the wavelength-dependent determination of the spectral responsivity of fluorescence measuring devices like spectrofluorometers. To cover the wavelength region from 400 to 800 nm, two new near-infrared emissive dyes were included, which were spectroscopically characterized in solution and encapsulated in the beads. The resulting set of beads presents the first step towards a new platform of spectral calibration beads for the determination of the spectral characteristics of fluorescence instruments like fluorescence microscopes, FCM setups, and microtiter plate readers, thereby meeting the increasing demand for reliable and comparable fluorescence data especially in strongly regulated areas, e.g., medical diagnostics. This will eventually provide the basis for standardized calibration procedures for imaging systems as an alternative to microchannel slides containing dye solutions previously reported by us. Graphical abstract.
Collapse
Affiliation(s)
- Katrin Hoffmann
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Str. 11, 12489, Berlin, Germany
| | | | - Ute Resch-Genger
- BAM Federal Institute for Materials Research and Testing, Richard-Willstaetter-Str. 11, 12489, Berlin, Germany.
| |
Collapse
|
16
|
Hawley TS, Hawley RG, Telford WG. Fluorescent Proteins for Flow Cytometry. ACTA ACUST UNITED AC 2017; 80:9.12.1-9.12.20. [PMID: 28369764 DOI: 10.1002/cpcy.17] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Fluorescent proteins have become standard tools for cell and molecular biologists. The color palette of fluorescent proteins spans the ultraviolet, visible, and near-infrared spectrum. Utility of fluorescent proteins has been greatly facilitated by the availability of compact and affordable solid state lasers capable of providing various excitation wavelengths. In theory, the plethora of fluorescent proteins and lasers make it easy to detect multiple fluorescent proteins simultaneously. However, in practice, heavy spectral overlap due to broad excitation and emission spectra presents a challenge. In conventional flow cytometry, careful selection of excitation wavelengths and detection filters is necessary. Spectral flow cytometry, an emerging methodology that is not confined by the "one color, one detector" paradigm, shows promise in the facile detection of multiple fluorescent proteins. This chapter provides a synopsis of fluorescent protein development, a list of commonly used fluorescent proteins, some practical considerations and strategies for detection, and examples of applications. © 2017 by John Wiley & Sons, Inc.
Collapse
Affiliation(s)
- Teresa S Hawley
- Flow Cytometry Core Facility, Laboratory of Genome Integrity, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| | - Robert G Hawley
- Department of Anatomy and Regenerative Biology, George Washington University School of Medicine and Health Sciences, Washington, D.C
| | - William G Telford
- Flow Cytometry Core Facility, Experimental Transplantation and Immunology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
17
|
Adan A, Alizada G, Kiraz Y, Baran Y, Nalbant A. Flow cytometry: basic principles and applications. Crit Rev Biotechnol 2016; 37:163-176. [DOI: 10.3109/07388551.2015.1128876] [Citation(s) in RCA: 377] [Impact Index Per Article: 47.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Aysun Adan
- Faculty of Life and Natural Sciences, Abdullah Gül University, Kayseri, Turkey and
| | - Günel Alizada
- Department of Molecular Biology and Genetics, İzmir Institute of Technology, İzmir, Turkey
| | - Yağmur Kiraz
- Faculty of Life and Natural Sciences, Abdullah Gül University, Kayseri, Turkey and
- Department of Molecular Biology and Genetics, İzmir Institute of Technology, İzmir, Turkey
| | - Yusuf Baran
- Faculty of Life and Natural Sciences, Abdullah Gül University, Kayseri, Turkey and
- Department of Molecular Biology and Genetics, İzmir Institute of Technology, İzmir, Turkey
| | - Ayten Nalbant
- Department of Molecular Biology and Genetics, İzmir Institute of Technology, İzmir, Turkey
| |
Collapse
|
18
|
Tárnok A. Leukocytes Don't Lie. Cytometry A 2015; 87:791-2. [PMID: 26317921 DOI: 10.1002/cyto.a.22737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Accepted: 07/31/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Attila Tárnok
- Department of Pediatric Cardiology, Heart Centre Leipzig, University of Leipzig, Leipzig, Germany.,Institute of Clinical Immunology, Medical Faculty, University of Leipzig, Leipzig, Germany
| |
Collapse
|
19
|
Futamura K, Sekino M, Hata A, Ikebuchi R, Nakanishi Y, Egawa G, Kabashima K, Watanabe T, Furuki M, Tomura M. Novel full-spectral flow cytometry with multiple spectrally-adjacent fluorescent proteins and fluorochromes and visualization of in vivo cellular movement. Cytometry A 2015. [PMID: 26217952 PMCID: PMC5132038 DOI: 10.1002/cyto.a.22725] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Flow cytometric analysis with multicolor fluoroprobes is an essential method for detecting biological signatures of cells. Here, we present a new full-spectral flow cytometer (spectral-FCM). Unlike conventional flow cytometer, this spectral-FCM acquires the emitted fluorescence for all probes across the full-spectrum from each cell with 32 channels sequential PMT unit after dispersion with prism, and extracts the signals of each fluoroprobe based on the spectral shape of each fluoroprobe using unique algorithm in high speed, high sensitive, accurate, automatic and real-time. The spectral-FCM detects the continuous changes in emission spectra from green to red of the photoconvertible protein, KikGR with high-spectral resolution and separates spectrally-adjacent fluoroprobes, such as FITC (Emission peak (Em) 519 nm) and EGFP (Em 507 nm). Moreover, the spectral-FCM can measure and subtract autofluorescence of each cell providing increased signal-to-noise ratios and improved resolution of dim samples, which leads to a transformative technology for investigation of single cell state and function. These advances make it possible to perform 11-color fluorescence analysis to visualize movement of multilinage immune cells by using KikGR-expressing mice. Thus, the novel spectral flow cytometry improves the combinational use of spectrally-adjacent various FPs and multicolor fluorochromes in metabolically active cell for the investigation of not only the immune system but also other research and clinical fields of use.
Collapse
Affiliation(s)
- Koji Futamura
- FCM Business Department, Life Science Business Division, Medical Business Unit, Sony Corporation, Minato-Ku, Tokyo, 108-0075, Japan
| | - Masashi Sekino
- Concept Development Department, Application Technology Development Division, System R&D Group, RDS Platform, Sony Corporation, Shinagawa-Ku, Tokyo, 141-0001, Japan
| | - Akihiro Hata
- Center for Innovation in Immunoregulative Technology and Therapeutics, Kyoto University Graduate School of Medicine, Yoshida-Konoe, Kyoto, 606-8501, Japan
| | - Ryoyo Ikebuchi
- Center for Innovation in Immunoregulative Technology and Therapeutics, Kyoto University Graduate School of Medicine, Yoshida-Konoe, Kyoto, 606-8501, Japan.,Laboratory of Immunology, Faculty of Pharmacy, Osaka Ohtani University, 3-11-1 Nishikiorikita, Tondabayashi-City, Osaka Prefecture, 584-8540, Japan
| | - Yasutaka Nakanishi
- Center for Innovation in Immunoregulative Technology and Therapeutics, Kyoto University Graduate School of Medicine, Yoshida-Konoe, Kyoto, 606-8501, Japan
| | - Gyohei Egawa
- Department of Dermatology, Kyoto University Graduate School of Medicine, Kyoto, 606-8501, Japan
| | - Kenji Kabashima
- Department of Dermatology, Kyoto University Graduate School of Medicine, Kyoto, 606-8501, Japan
| | - Takeshi Watanabe
- Center for Innovation in Immunoregulative Technology and Therapeutics, Kyoto University Graduate School of Medicine, Yoshida-Konoe, Kyoto, 606-8501, Japan.,The Tazuke-Kofukai Medical Research Institute/Kitano Hospital, 2-4-20 Ohgimachi, Kita-Ku, Osaka, 530-8480, Japan
| | - Motohiro Furuki
- FCM Business Department, Life Science Business Division, Medical Business Unit, Sony Corporation, Minato-Ku, Tokyo, 108-0075, Japan
| | - Michio Tomura
- Center for Innovation in Immunoregulative Technology and Therapeutics, Kyoto University Graduate School of Medicine, Yoshida-Konoe, Kyoto, 606-8501, Japan.,Laboratory of Immunology, Faculty of Pharmacy, Osaka Ohtani University, 3-11-1 Nishikiorikita, Tondabayashi-City, Osaka Prefecture, 584-8540, Japan
| |
Collapse
|
20
|
Zhou H, Gunsten SP, Zhegalova NG, Bloch S, Achilefu S, Christopher Holley J, Schweppe D, Akers W, Brody SL, Eades WC, Berezin MY. Visualization of pulmonary clearance mechanisms via noninvasive optical imaging validated by near-infrared flow cytometry. Cytometry A 2015; 87:419-27. [PMID: 25808737 DOI: 10.1002/cyto.a.22658] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Revised: 02/05/2015] [Accepted: 02/24/2015] [Indexed: 12/21/2022]
Abstract
In vivo optical imaging with near-infrared (NIR) probes is an established method of diagnostics in preclinical and clinical studies. However, the specificities of these probes are difficult to validate ex vivo due to the lack of NIR flow cytometry. To address this limitation, we modified a flow cytometer to include an additional NIR channel using a 752 nm laser line. The flow cytometry system was tested using NIR microspheres and cell lines labeled with a combination of visible range and NIR fluorescent dyes. The approach was verified in vivo in mice evaluated for immune response in lungs after intratracheal delivery of the NIR contrast agent. Flow cytometry of cells obtained from the lung bronchoalveolar lavage demonstrated that the NIR dye was taken up by pulmonary macrophages as early as 4-h post-injection. This combination of optical imaging with NIR flow cytometry extends the capability of imaging and enables complementation of in vivo imaging with cell-specific studies.
Collapse
Affiliation(s)
- Haiying Zhou
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Nedbal J, Visitkul V, Ortiz-Zapater E, Weitsman G, Chana P, Matthews DR, Ng T, Ameer-Beg SM. Time-domain microfluidic fluorescence lifetime flow cytometry for high-throughput Förster resonance energy transfer screening. Cytometry A 2015; 87:104-18. [PMID: 25523156 PMCID: PMC4440390 DOI: 10.1002/cyto.a.22616] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2014] [Revised: 11/12/2014] [Accepted: 12/03/2014] [Indexed: 01/22/2023]
Abstract
Sensing ion or ligand concentrations, physico-chemical conditions, and molecular dimerization or conformation change is possible by assays involving fluorescent lifetime imaging. The inherent low throughput of imaging impedes rigorous statistical data analysis on large cell numbers. We address this limitation by developing a fluorescence lifetime-measuring flow cytometer for fast fluorescence lifetime quantification in living or fixed cell populations. The instrument combines a time-correlated single photon counting epifluorescent microscope with microfluidics cell-handling system. The associated computer software performs burst integrated fluorescence lifetime analysis to assign fluorescence lifetime, intensity, and burst duration to each passing cell. The maximum safe throughput of the instrument reaches 3,000 particles per minute. Living cells expressing spectroscopic rulers of varying peptide lengths were distinguishable by Förster resonant energy transfer measured by donor fluorescence lifetime. An epidermal growth factor (EGF)-stimulation assay demonstrated the technique's capacity to selectively quantify EGF receptor phosphorylation in cells, which was impossible by measuring sensitized emission on a standard flow cytometer. Dual-color fluorescence lifetime detection and cell-specific chemical environment sensing were exemplified using di-4-ANEPPDHQ, a lipophilic environmentally sensitive dye that exhibits changes in its fluorescence lifetime as a function of membrane lipid order. To our knowledge, this instrument opens new applications in flow cytometry which were unavailable due to technological limitations of previously reported fluorescent lifetime flow cytometers. The presented technique is sensitive to lifetimes of most popular fluorophores in the 0.5-5 ns range including fluorescent proteins and is capable of detecting multi-exponential fluorescence lifetime decays. This instrument vastly enhances the throughput of experiments involving fluorescence lifetime measurements, thereby providing statistically significant quantitative data for analysis of large cell populations. © 2014 International Society for Advancement of Cytometry.
Collapse
Affiliation(s)
- Jakub Nedbal
- Division of Cancer Studies, King's College LondonUnited Kingdom
- Randall Division of Cell and Molecular Biophysics, King's College LondonUnited Kingdom
| | - Viput Visitkul
- Randall Division of Cell and Molecular Biophysics, King's College LondonUnited Kingdom
| | - Elena Ortiz-Zapater
- Division of Asthma, Allergy & Lung Biology, King's College LondonUnited Kingdom
| | | | - Prabhjoat Chana
- Immune Monitoring Laboratory, NIHR Biomedical Research Centre at Guy's and St Thomas' NHS Foundation Trust and King's College LondonUnited Kingdom
| | - Daniel R Matthews
- Queensland Brain Institute, The University of QueenslandSt Lucia, Australia
| | - Tony Ng
- Division of Cancer Studies, King's College LondonUnited Kingdom
- Randall Division of Cell and Molecular Biophysics, King's College LondonUnited Kingdom
- UCL Cancer Institute, University College LondonUnited Kingdom
| | - Simon M Ameer-Beg
- Division of Cancer Studies, King's College LondonUnited Kingdom
- Randall Division of Cell and Molecular Biophysics, King's College LondonUnited Kingdom
| |
Collapse
|
22
|
Plouffe BD, Murthy SK, Lewis LH. Fundamentals and application of magnetic particles in cell isolation and enrichment: a review. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2015; 78:016601. [PMID: 25471081 PMCID: PMC4310825 DOI: 10.1088/0034-4885/78/1/016601] [Citation(s) in RCA: 176] [Impact Index Per Article: 19.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Magnetic sorting using magnetic beads has become a routine methodology for the separation of key cell populations from biological suspensions. Due to the inherent ability of magnets to provide forces at a distance, magnetic cell manipulation is now a standardized process step in numerous processes in tissue engineering, medicine, and in fundamental biological research. Herein we review the current status of magnetic particles to enable isolation and separation of cells, with a strong focus on the fundamental governing physical phenomena, properties and syntheses of magnetic particles and on current applications of magnet-based cell separation in laboratory and clinical settings. We highlight the contribution of cell separation to biomedical research and medicine and detail modern cell-separation methods (both magnetic and non-magnetic). In addition to a review of the current state-of-the-art in magnet-based cell sorting, we discuss current challenges and available opportunities for further research, development and commercialization of magnetic particle-based cell-separation systems.
Collapse
Affiliation(s)
- Brian D Plouffe
- Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA. The Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA 02115, USA
| | | | | |
Collapse
|
23
|
Plášek J, Gášková D. A method for determining supernatant-free spectra generated from fluorescently stained cells in suspension. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY 2014; 141:139-44. [PMID: 25463661 DOI: 10.1016/j.jphotobiol.2014.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2014] [Revised: 09/28/2014] [Accepted: 10/11/2014] [Indexed: 11/16/2022]
Abstract
Here we present a fluorometric method for direct determination of supernatant-free fluorescence spectra generated from fluorescently stained cells in suspension. The key element in the new technique is the design of an adapter to a standard cuvette holder that makes it possible to measure front-face fluorescence spectra from thin layers of cells spun down to the bottom of a spectrofluorometric cuvette. We have demonstrated the applicability of this approach and its analytical potential using the suspensions of yeast cells stained with the potentiometric dye of 3,3'-dipropylthiadicarbocyanine, diS-C3(3), and with the specific cell-wall marker calcofluor.
Collapse
Affiliation(s)
- Jaromír Plášek
- Charles University, Faculty of Mathematics and Physics, Ke Karlovu 3, 12116 Prague, Czech Republic.
| | - Dana Gášková
- Charles University, Faculty of Mathematics and Physics, Ke Karlovu 3, 12116 Prague, Czech Republic
| |
Collapse
|
24
|
Grégori G, Rajwa B, Patsekin V, Jones J, Furuki M, Yamamoto M, Paul Robinson J. Hyperspectral cytometry. Curr Top Microbiol Immunol 2014; 377:191-210. [PMID: 24271566 DOI: 10.1007/82_2013_359] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
Hyperspectral cytometry is an emerging technology for single-cell analysis that combines ultrafast optical spectroscopy and flow cytometry. Spectral cytometry systems utilize diffraction gratings or prism-based monochromators to disperse fluorescence signals from multiple labels (organic dyes, nanoparticles, or fluorescent proteins) present in each analyzed bioparticle onto linear detector arrays such as multianode photomultipliers or charge-coupled device sensors. The resultant data, consisting of a series of characterizing every analyzed cell, are not compensated by employing the traditional cytometry approach, but rather are spectrally unmixed utilizing algorithms such as constrained Poisson regression or non-negative matrix factorization. Although implementations of spectral cytometry were envisioned as early as the 1980s, only recently has the development of highly sensitive photomultiplier tube arrays led to design and construction of functional prototypes and subsequently to introduction of commercially available systems. This chapter summarizes the historical efforts and work in the field of spectral cytometry performed at Purdue University Cytometry Laboratories and describes the technology developed by Sony Corporation that resulted in release of the first commercial spectral cytometry system-the Sony SP6800. A brief introduction to spectral data analysis is also provided, with emphasis on the differences between traditional polychromatic and spectral cytometry approaches.
Collapse
Affiliation(s)
- Gérald Grégori
- Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, 47907, USA
| | | | | | | | | | | | | |
Collapse
|
25
|
Nolan JP, Duggan E, Condello D. Optimization of SERS tag intensity, binding footprint, and emittance. Bioconjug Chem 2014; 25:1233-42. [PMID: 24892497 PMCID: PMC4215889 DOI: 10.1021/bc5000252] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2014] [Revised: 05/05/2014] [Indexed: 11/30/2022]
Abstract
Nanoparticle surface enhanced Raman scattering (SERS) tags have attracted interest as labels for use in a variety of applications, including biomolecular assays. An obstacle to progress in this area is a lack of standardized approaches to compare the brightness of different SERS tags within and between laboratories. Here we present an approach based on binding of SERS tags to beads with known binding capacities that allows evaluation of the average intensity, the relative binding footprint of particles in a SERS tag preparation, and the size-normalized intensity or emittance. We tested this on four different SERS tag compositions and show that aggregated gold nanorods produce SERS tags that are 2-4 times brighter than relatively more monodisperse nanorods, but that the aggregated nanorods are also correspondingly larger, which may negate the intensity if steric hindrance limits the number of tags bound to a target. By contrast, SERS tags prepared from smaller gold nanorods coated with a silver shell produce SERS tags that are 2-3 times brighter, on a size-normalized basis, than the Au nanorod-based tags, resulting in labels with improved performance in SERS-based image and flow cytometry assays. SERS tags based on red-resonant Ag plates showed similarly bright signals and small footprint. This approach to evaluating SERS tag brightness is general, uses readily available reagents and instruments, and should be suitable for interlab comparisons of SERS tag brightness.
Collapse
Affiliation(s)
| | - Erika Duggan
- La Jolla Bioengineering
Institute Suite 210 3535
General Atomics Court San Diego, California 92121, United States
| | - Danilo Condello
- La Jolla Bioengineering
Institute Suite 210 3535
General Atomics Court San Diego, California 92121, United States
| |
Collapse
|
26
|
Nolan JP. Knowing the code. Cytometry A 2014; 85:10-1. [PMID: 24591112 DOI: 10.1002/cyto.a.22419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2013] [Accepted: 11/01/2013] [Indexed: 11/08/2022]
Affiliation(s)
- John P Nolan
- La Jolla Bioengineering Institute, La Jolla, California
| |
Collapse
|
27
|
Sanders CK, Mourant JR. Advantages of full spectrum flow cytometry. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:037004. [PMID: 23478809 PMCID: PMC3592788 DOI: 10.1117/1.jbo.18.3.037004] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2013] [Revised: 02/14/2013] [Accepted: 02/15/2013] [Indexed: 06/01/2023]
Abstract
A charge coupled device-based flow-cytometer for the measurement of full spectra was implemented and characterized. The spectral resolution was better than 1.5 nm and the coefficient of variation for fluorescence from flow check beads was 5% or better. Both cell and bead data were analyzed by fitting to measured component spectra. Separation of flow check and align flow beads, which have similar spectra, was nearly identical whether using a spectral analysis or a scatter analysis. After mixing, cells stained with ethidium bromide or propidium iodide were measured at different timepoints. The contribution of these 12 nm separated emission spectra could be separately quantified and the kinetic process of the samples becoming homogeneous due to fluorophor dissociation and rebinding was observed. Principle component analysis was used to reduce noise and alternating least squares (ALS) was used to analyze one set of noise-reduced cell data without knowledge of the component spectra. The component spectra obtained via ALS are very similar to the measured component spectra. The contributions of ethidium bromide and propidium iodide to the individual spectra are also similar to those obtained via the spectral fitting procedure.
Collapse
Affiliation(s)
- Claire K Sanders
- Bioscience Division, Los Alamos National Laboratory, P.O. Box 1663, MS M888, Los Alamos, New Mexico 87544, USA.
| | | |
Collapse
|