1
|
Dürr HR, Hett M, Klein A, Rakete S, Holzapfel BM, Lahr C. Highly Elevated Metal Ion Levels After Tumor Resections and Reconstruction With Megaprostheses Around the Knee. Clin Orthop Relat Res 2025:00003086-990000000-02001. [PMID: 40279194 DOI: 10.1097/corr.0000000000003515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Accepted: 04/07/2025] [Indexed: 04/27/2025]
Abstract
BACKGROUND Tumor resections around the knee leave defects that are often reconstructed with megaprostheses. Because megaprostheses have a large surface area, modular design, and constrained coupling mechanism, they are prone to metal wear, which can result in elevated levels of metal ions, particularly cobalt (Co) and chromium (Cr). Currently, there are limited published data on elevated ion levels in megaprostheses but not in a homogeneous, well-defined patient population with respect to location and type of prosthesis. QUESTIONS/PURPOSES What metal ion levels were observed in patients who underwent distal femoral or proximal tibial megaprostheses at a minimum follow-up time of 1 year? METHODS Between May 1992 and November 2023, we performed 81 total knee megaprostheses as part of tumor reconstructions. Of those, we considered 65 surviving patients as potentially eligible. Based on that, 34% (22) were excluded because they did not respond and were lost to follow-up or refused to participate, leaving 66% (43) for analysis in this study at a median (range) follow-up time of 88 months (13 to 379). Whole blood samples were obtained and analyzed for Co and Cr. Medical records were reviewed, and signs of metallosis were assessed. RESULTS Elevated levels of Co and Cr were found in 95% (41 of 43) of patients. The levels of both ions were found to correlate with each other. For distal femoral and proximal tibial replacement, the median (range) Co levels were 13.7 µg/L (1.0 to 91.5) and 7.3 µg/L (0.8 to 19.9), respectively. For Cr, the values were 9.6 µg/L (0.5 to 22.3) and 7.2 µg/L (0.5 to 7.2), respectively (p = 0.07). The length of resection was not associated with ion concentrations. Metallosis was observed in 26% (11 of 43) of patients either visible through the skin at presentation or noted at the time of a revision procedure. Mechanical failure (such as breakage of the joint mechanism and loosening of the stems), increased BMI, and adjuvant therapies were not associated with elevated blood ions. Both Co and Cr levels were lower in patients measured at longer follow-up compared with those measured earlier after arthroplasty. CONCLUSION Based on our results, elevated ion levels are common in patients with megaprostheses. In addition, we note that 21% (9 of 43) of patients had Co levels above 20 µg/L, which is worrisome. Considering that the patients in this and other studies showed no clinical symptoms even with elevated ion levels, care must be taken not to alarm patients. We were not able to identify any factors associated with having higher ion level concentrations that could be used to define groups that could benefit from ion measurements. Currently, as we do not have good thresholds for when apparently high ion levels are worrisome, in patients with megaprostheses who develop unexplained cardiac or neurologic abnormalities, one might consider testing metal ion levels as part of the diagnostic process. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
- Hans Roland Dürr
- Orthopaedic Oncology, Department of Orthopaedics and Trauma Surgery, University Hospital, LMU Munich, Campus Großhadern, Munich, Germany
| | - Maria Hett
- Orthopaedic Oncology, Department of Orthopaedics and Trauma Surgery, University Hospital, LMU Munich, Campus Großhadern, Munich, Germany
| | - Alexander Klein
- Orthopaedic Oncology, Department of Orthopaedics and Trauma Surgery, University Hospital, LMU Munich, Campus Großhadern, Munich, Germany
| | - Stefan Rakete
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Inner City Campus, Munich, Germany
| | - Boris Michael Holzapfel
- Department of Orthopaedics and Trauma Surgery, University Hospital, LMU Munich, Campus Großhadern, Munich, Germany
| | - Christoph Lahr
- Department of Orthopaedics and Trauma Surgery, University Hospital, LMU Munich, Campus Großhadern, Munich, Germany
| |
Collapse
|
2
|
Gass HM, Goel RK, Heo K, Shah J, Wilson JM, Premkumar A. Do Intra-articular Metal Ion Levels Predict Adverse Local Tissue Reaction in Revision Total Hip Arthroplasty for Mechanically Assisted Crevice Corrosion? J Arthroplasty 2025; 40:1068-1073. [PMID: 39426441 DOI: 10.1016/j.arth.2024.10.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 10/09/2024] [Accepted: 10/14/2024] [Indexed: 10/21/2024] Open
Abstract
BACKGROUND Mechanically assisted crevice corrosion is a complication that may occur in vivo at modular metal interfaces following metal-on-polyethylene total hip arthroplasty (THA). Metal ions released in vivo may be associated with adverse local tissue reactions (ALTRs). While there is no definitive value, high serum ion levels are implicated as contributors to ALTR, and various screening levels have been recommended. The purpose of this investigation was to evaluate the relationship between synovial fluid (SF) cobalt and chromium ion levels and the risk of developing ALTR. METHODS This was a retrospective cohort study of 552 patients who underwent 621 metal-on-polyethylene primary THAs. A total of 69 patients underwent revision THA due to symptomatic primary failure with elevated serum metal ions levels. There were 28 who had preoperative serum and intraoperative SF chromium and cobalt samples. Patient demographics, surgical, and laboratory data were collected. Descriptive statistics, Mann-Whitney U, analysis of variance tests, and linear regression analyses were performed. RESULTS There were 40.6% of revisions that had preoperative serum and intraoperative SF samples. The mean time to revision was 5.7 (range, 3.8 to 7.6) years. Mean SF cobalt and chromium levels were 870.9mcg/L (range, 1.1 to 8,300.0) and 573.5mcg/L (range, 1.3 to 10,000.0). Mean serum and SF cobalt-chromium ratios were 4.0 (range, 0.9 to 7.1) and 6.4 (range, 0 to 15.1), respectively. Elevated serum cobalt levels were predictive of ALTR (P = 0.002), SF levels were not. Analysis of preoperative serum to SF cobalt-chromium ratios showed poor correlation (R2 = 0.05). CONCLUSIONS There was no correlation between SF ion levels and ALTR. Also, serum and intra-articular ion levels did not correlate. The SF levels did not provide additional value over serum levels for diagnosis or prognosis of mechanically assisted crevice corrosion. Further studies are needed to better understand the relationship between serum and SF ion levels and its relationship to ALTR.
Collapse
Affiliation(s)
- Henry M Gass
- Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia
| | - Rahul K Goel
- Duke Orthopaedic Surgery, Duke University School of Medicine, Durham, North Carolina
| | - Kevin Heo
- Emory University School of Medicine, Atlanta, Georgia
| | - Jason Shah
- Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia
| | - Jacob M Wilson
- Department of Orthopaedic Surgery, Vanderbilt Unversity Medical Center, Vanderbilt University, Nashville, Tennessee
| | - Ajay Premkumar
- Department of Orthopaedics, Emory University School of Medicine, Atlanta, Georgia
| |
Collapse
|
3
|
Meier J, Hembus J, Bader R, Vogel D. Computer-based analysis of the taper connection strength of different revision head and adapter sleeve designs. BIOMED ENG-BIOMED TE 2024; 69:199-209. [PMID: 37698840 DOI: 10.1515/bmt-2023-0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 08/28/2023] [Indexed: 09/13/2023]
Abstract
OBJECTIVES Ceramic revision heads, equipped with titanium adapter sleeves, are used in femoral head revision in total hip arthroplasty to avoid ceramic fracture due to the damaged taper. METHODS A finite element analysis of the taper connection strength of revision heads with varying head diameters combined with adapter sleeves of different lengths was conducted. The influence of various assembly forces, head diameter, and length of the adapter sleeves was evaluated. For two combinations, the pattern of contact pressure was evaluated when applying a simplified joint load (3 kN, 45° load angle). Experimental validation was conducted with 36 mm heads and adapter sleeves in size S, as well as 28 mm heads and adapter sleeves in size XL. RESULTS The pull-off force increased with higher assembly forces. Using larger head diameters and adapter sleeves led to decreased pull-off forces, a reduced contact surface, and less contact pressure. The contact pressure showed significant peaks and a diagonal pattern under 45° angle loading when assembly forces were less than 4 kN, and larger adapter sleeves were utilized. CONCLUSION A sufficient assembly force should be ensured intraoperatively, especially with an increasing head diameter and adapter sleeve size, as lower assembly forces might lead to reduced taper connection strength.
Collapse
Affiliation(s)
- Johanna Meier
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Jessica Hembus
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Danny Vogel
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
4
|
Insua A, Galindo-Moreno P, Miron RJ, Wang HL, Monje A. Emerging factors affecting peri-implant bone metabolism. Periodontol 2000 2024; 94:27-78. [PMID: 37904311 DOI: 10.1111/prd.12532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 08/05/2023] [Accepted: 09/10/2023] [Indexed: 11/01/2023]
Abstract
Implant dentistry has evolved to the point that standard implant osseointegration is predictable. This is attributed in part to the advancements in material sciences that have led toward improvements in implant surface technology and characteristics. Nonetheless, there remain several cases where implant therapy fails (specifically at early time points), most commonly attributed to factors affecting bone metabolism. Among these patients, smokers are known to have impaired bone metabolism and thus be subject to higher risks of early implant failure and/or late complications related to the stability of the peri-implant bone and mucosal tissues. Notably, however, emerging data have unveiled other critical factors affecting osseointegration, namely, those related to the metabolism of bone tissues. The aim of this review is to shed light on the effects of implant-related factors, like implant surface or titanium particle release; surgical-related factors, like osseodensification or implanted biomaterials; various drugs, like selective serotonin reuptake inhibitors, proton pump inhibitors, anti-hypertensives, nonsteroidal anti-inflammatory medication, and statins, and host-related factors, like smoking, diet, and metabolic syndrome on bone metabolism, and aseptic peri-implant bone loss. Despite the infectious nature of peri-implant biological complications, these factors must be surveyed for the effective prevention and management of peri-implantitis.
Collapse
Affiliation(s)
- Angel Insua
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Pablo Galindo-Moreno
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
- Department of Oral Surgery and Implant Dentistry, University of Granada, Granada, Spain
| | - Richard J Miron
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Hom-Lay Wang
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Alberto Monje
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
- Department of Periodontology, University of Bern, Bern, Switzerland
- Department of Periodontology, Universitat Internacional de Catalunya, Barcelona, Spain
| |
Collapse
|
5
|
Yu R, Yuan Y, Liu Z, Liu L, Xu Z, Zhao Y, Jia C, Zhang P, Li H, Liu Y, Wang Y, Li W, Nie L, Sun X, Li Y, Liu B, Liu H. Selenomethionine against titanium particle-induced osteolysis by regulating the ROS-dependent NLRP3 inflammasome activation via the β-catenin signaling pathway. Front Immunol 2023; 14:1171150. [PMID: 37545495 PMCID: PMC10397397 DOI: 10.3389/fimmu.2023.1171150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 06/22/2023] [Indexed: 08/08/2023] Open
Abstract
Wear debris-induced osteolysis, especially titanium (Ti) particles-induced osteolysis, is the most common cause of arthroplasty failure with no effective therapy. Previous studies have suggested that inflammation and impaired osteogenesis are associated with Ti particles -induced osteolysis. Selenium (Se) is an essential trace element in the human body, which forms selenomethionine (Se-Met) in nature, and selenoproteins has strong anti-inflammatory and antioxidant stress effects. In this study, the effects of Se-Met on Ti particles-induced osteolysis were observed and the potential mechanism was explored. We found that exogenous Se-Met relieved osteolysis induced by Ti particles in two animal models and MC3T3-E1 cells. We found that the addition of Se-Met effectively inhibited Ti particle-induced inflammation by regulating reactive oxygen species-dependent (ROS-dependent) NOD-like receptor protein 3 (NLRP3) inflammasome activation. These therapeutic effects were abrogated in MC3T3-E1 cells that had received a β-catenin antagonist, suggesting that Se-Met alleviates inflammatory osteolysis via the β-catenin signaling pathway. Collectively, these findings indicated that Se-Met may serve as a potential therapeutic agent for treating Ti particle-induced osteolysis.
Collapse
Affiliation(s)
- Ruixuan Yu
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Yongjian Yuan
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Zhicheng Liu
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
- The First Clinical Medical School, Shandong University, Jinan, Shandong, China
| | - Long Liu
- Department of Pathology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Zhaoning Xu
- School of Nursing and Rehabilitation, Shandong University, Jinan, Shandong, China
| | - Yunpeng Zhao
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Chunwang Jia
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Pengfei Zhang
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Hang Li
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Yuhao Liu
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Yi Wang
- Department of Plastic and Burns Surgery, The Second Hospital of Shandong University, Jinan, Shandong, China
- Emergency Medicine Center, The Second Hospital of Shandong University, Jinan, Shandong, China
| | - Weiwei Li
- Department of Pathology, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Lin Nie
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Xuecheng Sun
- Department of Orthopedic Trauma, Weifang People’s Hospital, Weifang, Shandong, China
| | - Yuhua Li
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Ben Liu
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Haichun Liu
- Department of Orthopaedics, Qilu Hospital of Shandong University, Jinan, Shandong, China
| |
Collapse
|
6
|
Migliorini F, Pilone M, Bell A, Merfort R, Giorgino R, Maffulli N. Serum cobalt and chromium concentration following total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2023; 13:6918. [PMID: 37106086 PMCID: PMC10140036 DOI: 10.1038/s41598-023-34177-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/25/2023] [Indexed: 04/29/2023] Open
Abstract
The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany.
| | - Marco Pilone
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany
| | - Ricarda Merfort
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Riccardo Giorgino
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- School of Pharmacy and Bioengineering, Faculty of Medicine, Keele University, ST4 7QB, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Queen Mary University of London, Mile End Hospital, E1 4DG, London, England
| |
Collapse
|
7
|
Mok JM, Poelstra K, Ammar K, McGirt M, Cormier J, Hart R, Bauman J, Cowart P, Sheth I, Singh P, Yadav J. Characterization of ion release from a novel biomaterial, Molybdenum-47.5Rhenium, in physiologic environments. Spine J 2023; 23:900-911. [PMID: 36706920 DOI: 10.1016/j.spinee.2023.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 01/02/2023] [Accepted: 01/18/2023] [Indexed: 01/26/2023]
Abstract
BACKGROUND CONTEXT Metals from spinal implants are released into surrounding tissues by various mechanisms. Metal ion release has been associated with clinical implant failure, osteolysis, and remote site accumulation with adverse events. Significant corrosion and associated metal ion release has been described with currently used spinal implant alloys. A novel metal alloy, Molybdenum-47.5Rhenium alloy (MoRe®), was approved for use in medical implants in 2019 by the FDA. PURPOSE To evaluate the metal ion release profile of MoRe alloy after immersion in both a stable physiologic, as well as in an inflammatory environment. STUDY DESIGN In vitro study. METHODS The ion release profile of the MoRe alloy was comprehensively evaluated in-vitro after prolonged immersion in physiologic and inflammatory environments. Ion concentration analyses were then conducted using inductively coupled plasma-mass spectrometry (ICP-MS) methods. Comparative testing of titanium (Ti-6Al-4V) and cobalt chromium (Co-28Cr-6Mo) was also performed. RESULTS Under baseline physiologic conditions, the MoRe alloy demonstrates very low molybdenum and rhenium ion release rates throughout the 30-day test period. During the first time interval (day 0-1), low levels of molybdenum and rhenium ions are detected (<0.3 μg/cm2 day) followed by a rapid reduction in the ion release rates to <0.05 μg/cm2 day during the second time interval (days 1-3) followed by a further reduction to very low steady-state rates <0.01 μg/cm2 day during the third time interval (days 3-7), which were maintained through 30 days. In the inflammatory condition (H2O2 solution), there was a transient increase in the release of molybdenum and rhenium ions, followed by a return to baseline ion release rates (days 2-4), with a further reduction to low steady-state rates of ∼0.01 μg/cm2 day (days 4-8). The measured molybdenum and rhenium ion release rates in both steady state (<0.01 μg/cm2 day), and inflammatory environments (0.01 μg/cm2 day) were far below the established FDA-permitted daily exposure (PDE) of 1,900 μg/cm2 day for molybdenum and 4,400 μg/cm2 day for rhenium. In contrast, titanium and cobalt chromium approached or exceeded their established PDE values in an inflammatory environment. CONCLUSIONS The novel biomaterial MoRe demonstrated a lower metal ion release profile in both a physiologic and inflammatory environment and was well below the established PDE. Comparative testing of the cobalt-chromium and titanium alloys found higher levels of ion release in the inflammatory environment that exceeded the PDE for cobalt and vanadium.
Collapse
Affiliation(s)
- James M Mok
- NorthShore University Health System, 9600 Gross Point Rd Suite 1200, Skokie, IL 60076, USA.
| | - Kornelis Poelstra
- Nevada Spine Clinic-Allegiant Spine Institute, President-The Robotic Spine Institute of Las Vegas, 7140 Smoke Ranch Rd, Las Vegas, NV 89128, USA
| | - Kevin Ammar
- Neurosurgical and Spine Institute, 4 E Jackson Blvd, Savannah, GA 31405, USA
| | - Matthew McGirt
- Carolina Neurosurgery & Spine Associates, 225 Baldwin Avenue, Charlotte, NC 28204, USA
| | - Jason Cormier
- Acadiana Neurosurgery, 118 rue Fontaine, Lafayette, LA 70508, USA
| | - Robert Hart
- Spine Specialists at SNI, 550 17th Ave Suite 500, Seattle, WA 98122, USA
| | - Jordan Bauman
- MiRus, LLC, 755 W. Oak Parkway Suite 100, Marietta, GA 30062, USA
| | - Pam Cowart
- MiRus, LLC, 755 W. Oak Parkway Suite 100, Marietta, GA 30062, USA
| | - Ishan Sheth
- School of Computer Science, Georgia Institute of Technology, 266 Ferst Dr NW, Atlanta, GA 30332, USA
| | - Preet Singh
- School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Dr, Erskine Love Building, Atlanta, GA 30332-0245, USA
| | - Jay Yadav
- MiRus, LLC, 755 W. Oak Parkway Suite 100, Marietta, GA 30062, USA
| |
Collapse
|
8
|
Anastasio AT, Johnson LG, Willhite JP, Mousallem T, Hendershot EF, Parekh SG. Team Approach: Metal Hypersensitivity in Total Joint Arthroplasty. JBJS Rev 2023; 11:01874474-202301000-00002. [PMID: 36722837 DOI: 10.2106/jbjs.rvw.22.00157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
» As total joint arthroplasty volume continues to grow nationwide, more uncommon complications such as metal implant hypersensitivity are reported with greater frequency in the literature. » Metal hypersensitivity is a challenging diagnosis given the potentially vague symptomology. It should be considered a diagnosis of exclusion, necessitating careful consideration of other potential etiologies of a failing implant before arriving at the final diagnosis of metal hypersensitivity. » Patients can experience substantial morbidity from implant rejection and in severe, refractory cases may even require revision arthroplasty and conversion to a hypoallergenic implant. » Given the complex nature of the condition, successful treatment of metal hypersensitivity to orthopaedic implants is best achieved through the use of a multidisciplinary, team-based approach. Immunologists, radiologists, and infectious disease physicians as well as orthopaedic surgeons and mechanical engineers are all vital in appropriate diagnosis and treatment of the condition.
Collapse
Affiliation(s)
| | - Lindsey G Johnson
- Campbell University School of Osteopathic Medicine, Lillington, North Carolina
| | | | | | | | | |
Collapse
|
9
|
Pratt NL, Cicuttini FM, Wang Y, Graves SE. No increased risk of cancer associated with metal-on-metal or ceramic-on-ceramic procedures compared to other bearing surfaces in patients with total hip arthroplasty: A nationwide linked registry cohort analysis of 167,837 patients. PLoS One 2022; 17:e0278241. [PMID: 36449468 PMCID: PMC9710777 DOI: 10.1371/journal.pone.0278241] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 11/14/2022] [Indexed: 12/02/2022] Open
Abstract
OBJECTIVES Studies have identified increased cancer risk among patients undergoing total hip arthroplasty (THA) compared to the general population. However, evidence of all-cause and site-specific cancer risk associated with different bearing surfaces has varied, with previous studies having short latency periods with respect to use of modern Metal-on-Metal (MoM) bearings. Using the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) linked to Australasian Association of Cancer Registries data, our aim was to evaluate risk of all-cause and site-specific cancer according to bearing surfaces in patients undergoing THA for osteoarthritis and whether risk increased with MoM bearings. METHODS Standardized incidence ratios (SIRs) and 95% confidence intervals (CIs) were calculated by comparing number of observed cancer cases to expected number based on incidence rate in the Australian population. All-cause and site-specific cancer rates were calculated for all conventional stemmed THA (csTHA) and resurfacing THA (rsTHA) procedures performed for osteoarthritis. Cox proportional hazards models were used to compare cancer rates for MoM, ceramic-on-ceramic (CoC) and resurfacing procedures with a comparison group comprising metal-on-polyethylene (MoP) or ceramic-on-polyethylene (CoP) procedures. RESULTS There were 156,516 patients with csTHA procedures and 11,321 with rsTHA procedures for osteoarthritis performed between 1999 and 2012. Incidence of all-cause cancer was significantly higher for csTHA (SIR 1.24, 95% CI 1.22-1.26) and rsTHA (SIR 1.74, 95% CI 1.39-2.04) compared to the Australian population. For csTHA, there was no significant difference in all-site cancer rates for MoM (Hazard Ratio (HR) 1.01, 95%CI 0.96-1.07) or CoC (HR 0.98, 95%CI 0.94-1.02) compared to MoP and CoP bearings. Significantly increased risk of melanoma, non-Hodgkins lymphoma, myeloma, leukaemia, prostate, colon, bladder and kidney cancer was found for csTHA and, prostate cancer, melanoma for rsTHA procedures when compared to the Australian population, although risk was not significantly different across bearing surfaces. CONCLUSIONS csTHA and rsTHA procedures were associated with increased cancer incidence compared to the Australian population. However, no excess risk was observed for MoM or CoC procedures compared to other bearing surfaces.
Collapse
Affiliation(s)
- Nicole L. Pratt
- Quality Use of Medicines and Pharmacy Research Centre, Clinical and Health Sciences, University of South Australia, Adelaide, South Australia, Australia
- * E-mail:
| | - Flavia M. Cicuttini
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
| | - Yuanyuan Wang
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
| | - Stephen E. Graves
- Australian Orthopaedic Association National Joint Replacement Registry, South Australian Health and Medical Research Institute, Adelaide, South Australia, Australia
- Clinical and Health Sciences, University of South Australia, Adelaide, South Australia, Australia
| |
Collapse
|
10
|
Abdel Hamid OI, Attia ME, Hirshon JM, El-Shinawi M, El-Hussaini M, El-Setouhy M. Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels. Drug Healthc Patient Saf 2022; 14:97-111. [PMID: 35880007 PMCID: PMC9308046 DOI: 10.2147/dhps.s360643] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 07/04/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Hip arthroplasty (HA) using implantable metal components is among the commonest orthopedic interventions. However, it can be followed by several complications following corrosion and the release of metal ions. Several studies proved that damaged genomic DNA may contribute to the pathophysiology of mental disorders. Aim The current work aims to evaluate the psychiatric disorders in metal on polyethylene hip arthroplasty (MOP-HA) patients and its correlation to cobalt/chromium (Co/Cr) levels and genotoxicity. Methods The work was a longitudinal follow-up study including 34 adults with unilateral primary MOP-HA meeting the inclusion and exclusion criteria. Preoperatively, 6, 12-months-postoperatively, patients were examined for cognitive impairment using mini-mental-state-examination (MMSE), depression using major-depressive-inventory (MDI), and blood samples were collected for estimation of Co/Cr, detection of genotoxicity by single-cell-gel-electrophoresis (comet assay) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG). Results Cognitive impairment was reported in 18.5% and 14.8% at 6-months, and 12-months postoperative, respectively. Depressive disorder was recorded in 22.2% at 6-months and 14.8% at 12-months postoperative. The marginal homogeneity tests proved a non-significant difference. There was a non-significant difference in preoperative, 6-months, 12-months postoperative MMSE, and MDI scores. There were significantly increased Co/Cr levels at 6-months postoperative. The levels decreased at 12-months postoperative, however, still significantly higher than preoperative values. There was a significant increase in serum 8-OHdG and the levels were positively correlated to cobalt levels at both 6 and 12-months-postoperative. There was a non-significant difference among preoperative, 6-months, and 12-months postoperative comet assay measurements. Conclusion From previous findings, we can conclude that will-functioning MOP hip arthroplasty can induce increased ion levels and positively correlated increase in biochemical markers of genotoxicity (8-OHdG).
Collapse
Affiliation(s)
- Omaima I Abdel Hamid
- Forensic Medicine and Clinical Toxicology Department, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Mohamed E Attia
- Orthopedics Departments, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Jon M Hirshon
- Department of Emergency Medicine, University of Maryland, School of Medicine, Baltimore, MD, USA
- Department of Epidemiology and Public Health, University of Maryland, School of Medicine, Baltimore, MD, USA
| | - Mohamed El-Shinawi
- Department of General Surgery, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Galala University, Galala City, Suez, Egypt
| | - Moustafa El-Hussaini
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Maged El-Setouhy
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Department of Family and Community Medicine, Faculty of Medince, Jazan University, Jazan, Kingdom of Saudi Arabia
| |
Collapse
|
11
|
Skjöldebrand C, Echeverri E, Hulsart-Billström G, Persson C. Tailoring the dissolution rate and in vitro cell response of silicon nitride coatings through combinatorial sputtering with chromium and niobium. Biomater Sci 2022; 10:3757-3769. [PMID: 35622079 DOI: 10.1039/d1bm01978c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Ceramic coatings have been widely investigated as a means to reduce wear and metallic ion release from joint implants. Silicon nitride-based coatings have been a topic of interest specifically due to their solubility in aqueous solutions. This could imply a reduced adverse immune response since the generated debris would dissolve. However, there are concerns regarding the dissolution rate and adhesion of these silicon nitride-based coatings. This study attempts to address the concern of dissolution rate as well as coating adhesion of silicon nitride coatings. We hypothesized that alloying with chromium and niobium would affect the adhesion, dissolution rate, and the resulting ion release and cell response to the coatings. A combinatorial approach was used to deposit sputtered coatings with compositional gradients both with and without a CrN interlayer. Compositional gradients were achieved for all the investigated elements: Si (38.6-46.9 at%), Nb (2.2-4.6 at%) and Cr (1.9-6.0 at%). However, while the presence of an interlayer reduced the delamination during adhesion testing, the differences in composition in the top coating did not affect the adhesion. Nor did the top coating's composition affect the surface roughness or the coatings' inherent mechanical properties (elastic modulus and hardness). All coating compositions were associated with a low Co release from the underlying metal and points with a higher Cr content (4.3-6.0 at%) gave an overall lower release of Si, Cr and Nb ions, possibly due to the formation of a stable oxide, which reduced the dissolution rate of the coating. Optimum chromium contents were furthermore found to give an enhanced in vitro fibroblast cell viability. In conclusion, the results indicate a possibility to tailor the ion release rate, which lends promise to further investigations such as tribocorrosive tests towards a future biomedical application.
Collapse
Affiliation(s)
- Charlotte Skjöldebrand
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Estefanía Echeverri
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Gry Hulsart-Billström
- Translational Imaging, Department of Medicinal Chemistry, Uppsala University, Sweden
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| |
Collapse
|
12
|
Wolf S, Johannessen AC, Ellison P, Furnes O, Hallan G, Rogg K, Skarstein K, Høl PJ. Inflammatory tissue reactions around aseptically loose cemented hip prostheses: A retrieval study of the Spectron EF stem with Reflection All-Poly acetabular cup. J Biomed Mater Res B Appl Biomater 2022; 110:1624-1636. [PMID: 35099116 PMCID: PMC9303329 DOI: 10.1002/jbm.b.35023] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 11/09/2021] [Accepted: 01/15/2022] [Indexed: 12/27/2022]
Abstract
The cemented Spectron EF stem in combination with the cemented non‐crosslinked Reflection All‐Poly cup showed a high rate of mid‐term aseptic loosening. However, the failure mechanisms are not fully known. We assessed the inflammatory tissue reactions and wear particles in periprosthetic tissues, implant wear and blood metal ion levels in 28 patients with failed implants. Histological analysis showed a macrophage pre‐dominant pattern with randomly distributed lymphocytes, with various amounts of neutrophils and giant cells. The number of different cell types in the tissue samples from patients in the cup group and in the stem group was similar. Wear particles, mainly ZrO2, CoCrMo, and polyethylene particles of different sizes and shapes, were associated with macrophages/giant cells, and total particle load/mm2 was higher in cases of stem loosening. The Spectron EF stems were heavily worn, abraded, and polished. Stem abrasion correlated with metal ion concentrations in blood. The median polyethylene wear rate of the Reflection cups was 0.23 mm/year. The high proximal roughness of the Spectron EF stem resulted in excessive cement wear during loosening. The resulting inflammatory tissue responses to the degradation products both from the cup and the stem led to massive osteolysis and subsequent implant loosening.
Collapse
Affiliation(s)
- Susann Wolf
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,National Institute of Occupational Health, Oslo, Norway
| | - Anne Christine Johannessen
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,Department of Pathology, Haukeland University Hospital, Bergen, Norway
| | - Peter Ellison
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Ove Furnes
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Geir Hallan
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Katharina Rogg
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Kathrine Skarstein
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,Department of Pathology, Haukeland University Hospital, Bergen, Norway
| | - Paul Johan Høl
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
13
|
Kasai K, Segawa R, Onodera R, Asakawa S, Hiratsuka M, Hirasawa N. Lactate released from human fibroblasts enhances Ni elution from Ni plate. Toxicology 2021; 453:152723. [PMID: 33596451 DOI: 10.1016/j.tox.2021.152723] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 02/05/2021] [Accepted: 02/09/2021] [Indexed: 11/19/2022]
Abstract
Elution of Ni ions from medical devices induces inflammation and toxicity. We previously reported that elution of Ni ions from Ni wires induced COX-2 expression and increased lactate production, but whether lactate is involved in the further elution of Ni ions remains unclear. In this study, using KMST-6, a human fibroblast cell line, we examined the molecular mechanisms by which Ni ions increase lactate release and the role of lactate in enhancing the elution of Ni ions. When KMST-6 cells were incubated on a Ni plate or stimulated with NiCl2 (1 mM), the expression of glucose transporter 1 (GLUT1), hexokinase 2 (HK2), and lactate dehydrogenase A (LDHA), and the release of lactate were enhanced. The NiCl2 (1 mM)-induced expression of these genes was inhibited by a hypoxia-inducible factor-1α (HIF-1α) inhibitor, PX-478 (10-25 μM). Stimulation of cells with a prolyl hydroxylase domain (PHD) inhibitor, roxadustat, increased the expression of these genes, lactate release, and elution of Ni ions at 10 μM. A monocarboxylate transporter-4 (MCT4) inhibitor, syrosingopine, inhibited lactate release from roxadustat-treated cells and reduced the elution of Ni ions by the cells at 10 μM. Finally, syrosingopine (10 μM) reduced the elution of Ni ions by the cells from the Ni plate. These results suggest that elution of Ni ions from metals promotes the production of lactate via HIF-1α-mediated gene expression and causes further Ni elution. Thus, Ni ions show a positive feedback mechanism of Ni elution, and this step may be potentially targeted to protect against metal elution from metal devices.
Collapse
Affiliation(s)
- Koji Kasai
- Laboratory of Pharmacotherapy of Life-Style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Miyagi, Japan
| | - Ryosuke Segawa
- Laboratory of Pharmacotherapy of Life-Style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Miyagi, Japan
| | - Ryo Onodera
- Laboratory of Pharmacotherapy of Life-Style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Miyagi, Japan
| | - Sanki Asakawa
- Laboratory of Pharmacotherapy of Life-Style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Miyagi, Japan
| | - Masahiro Hiratsuka
- Laboratory of Pharmacotherapy of Life-Style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Miyagi, Japan
| | - Noriyasu Hirasawa
- Laboratory of Pharmacotherapy of Life-Style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Miyagi, Japan.
| |
Collapse
|
14
|
Analysis of serum levels of titanium and aluminium ions in patients with early onset scoliosis operated upon using the magnetic growing rod-a single centre study of 14 patients. Spine Deform 2021; 9:1473-1478. [PMID: 34297320 PMCID: PMC8363538 DOI: 10.1007/s43390-021-00335-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 03/15/2021] [Indexed: 10/24/2022]
Abstract
STUDY DESIGN A cross-sectional retrospective Level 3 study. OBJECTIVE To study the serum levels of Titanium and Aluminium ions in patients operated using the magnetically controlled growing rod (MCGR) system. 14 consecutive patients of early onset scoliosis with varying etiology managed with MCGR system with a minimum follow-up of 24 months were selected for the study. The group consisted of two boys (14.3%) and 12 girls (85.7%). The average age of the patients at the time of surgery was 10.4 years (5-15 years). The average period of follow-up was 43.7 months (28-79 months). After informed consent of the subjects and their caretakers, serum levels of titanium and aluminium were measured. These levels were then assessed with regards to the number of screws used, number of distractions and complications. METHODS The concentration of titanium and aluminium ions in the serum was measured using high resolution inductively coupled plasma mass spectrometry. RESULTS For the sake of ease of assessment, patients were divided into three etiology-based groups-idiopathic (n = 6), neuromuscular (n = 2) and syndromic (n = 6). The mean serum titanium level was 15.9 μg/L (5.1-28.2 μg/L) while that of aluminium was 0.1 μmol/L (0.1-0.2 μmol/L). Of the 14 patients, 2 (14.2%) patients had mechanical failure (actuator pin dysfunction), 3 (21.4%) had rod breakage requiring revision surgery and one patient (7.1%) had surgical site infection managed with appropriate antibiotics. Patients undergoing revision for rod breakage did not show any metallosis of the tissues during surgery. CONCLUSION Analysis of patients with scoliosis operated using the magnetic growing rod system concludes that it is accompanied by presence of titanium in the blood but whether clinically significant or not needs to be ascertained by comparison of preoperative and postoperative blood concentrations of the titanium ions in individual subjects. The aluminium ion concentration remains within normal limits. Though implant malfunction may raise the titanium levels in the blood, its clinical significance needs to be determined. The aluminium levels are not affected irrespective to the presence or absence of complications. The long-term effects of raised titanium levels in the blood also warrant further prospective studies designed for precise and deeper analyses.
Collapse
|
15
|
She Z, Nie Y, Zhong H, Liu L, Yu S, Li Y. Effect of surface deformation on biocompatibility of biomedical alloys. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 119:111636. [PMID: 33321674 DOI: 10.1016/j.msec.2020.111636] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/10/2020] [Accepted: 10/13/2020] [Indexed: 11/15/2022]
Abstract
In this study, biocompatibility of Co-29Cr-5Mo (CCM), 316L steel (316L) and Ti-6Al-4V (TC4) alloys after surface plastic deformation under the condition comparable to the human ankle activities were investigated in details. Biocompatibility of all alloys decreases after surface deformation, while it is most significantly observed in CCM alloy. The different responses of biocompatibility are related to the corresponding microstructure evolution during surface deformation: martensitic phase transformation, dislocation slipping and mechanical twinning in CCM alloy result in the extremely localized microstructure, giving rise to the obviously decreased corrosion resistance or biocompatibility; quite homogenous microstructure after surface deformation leads to the slightly decreased corrosion resistance or biocompatibility in both 316L and TC4 alloys, since the surface deformation is dominated by slipping in 316L and by both slipping and a few mechanical twinning in TC4.
Collapse
Affiliation(s)
- Zhizhong She
- State Key Lab for Powder Metallurgy, Central South University, Changsha 410083, China
| | - Yan Nie
- State Key Lab for Powder Metallurgy, Central South University, Changsha 410083, China
| | - Hui Zhong
- School of Life Sciences, Central South University, Changsha 410013, China
| | - Lihong Liu
- Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Shu Yu
- National Key Laboratory of Science and Technology for High-strength Structural Materials, Central South University, Changsha 410083, China.
| | - Yunping Li
- State Key Lab for Powder Metallurgy, Central South University, Changsha 410083, China.
| |
Collapse
|
16
|
Influence of Different Damage Patterns of the Stem Taper on Fixation and Fracture Strength of Ceramic Ball Heads for Total Hip Replacement. BIOMED RESEARCH INTERNATIONAL 2020; 2020:7542062. [PMID: 32509869 PMCID: PMC7244970 DOI: 10.1155/2020/7542062] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/01/2020] [Accepted: 04/15/2020] [Indexed: 11/17/2022]
Abstract
Background Modularity finds frequent application in total hip replacement, allowing a preferable individual configuration and a simplified revision by retaining the femoral stem and replacing the prosthetic head. However, micromotions within the interface between the head and the stem taper can arise, resulting in the release of wear debris and corrosion products. The aim of our experimental study was to evaluate the influence of different taper damages on the fixation and fracture stability of ceramic femoral heads, after static and dynamic implant loading. Methods Ceramic ball heads (36 mm diameter) and 12/14 stem tapers made of titanium with various mild damage patterns (intact, scratched, and truncated) were tested. The heads were assembled on the taper with a quasistatic load of 2 kN and separated into a static and a dynamic group afterwards. The dynamic group (n = 18) was loaded over 1.5 million gait cycles in a hip wear simulator (ISO 14242-1). In contrast, the static group (n = 18) was not mechanically loaded after assembly. To determine the taper stability, all heads of the dynamic and static groups were either pulled off (ASTM 2009) or turned off (ISO 7206-16). A head fracture test (ISO 7206-10) was also performed. Subsequent to the fixation stability tests, the taper surface was visually evaluated in terms of any signs of wear or corrosion after the dynamic loading. Results In 10 of the 18 cases, discoloration of the taper was determined after the dynamic loading and subsequent cleaning, indicating the first signs of corrosion. Pull-off forces as well as turn-off moments were increased between 23% and 54% after the dynamic loading compared to the unloaded tapers. No significant influence of taper damage was determined in terms of taper fixation strength. However, the taper damage led to a decrease in fracture strength by approximately 20% (scratched) and 40% (truncated), respectively. Conclusion The results suggest that careful handling and accurate manufacturing of the stem taper are crucial for the ceramic head fracture strength, even though a mild damage showed no significant influence on taper stability. Moreover, our data indicate that a further seating of the prosthetic head may occur during daily activities, when the resulting hip force increases the assembly load.
Collapse
|
17
|
Wang Q, Eltit F, Garbuz D, Duncan C, Masri B, Greidanus N, Wang R. CoCrMo metal release in metal‐on‐highly crosslinked polyethylene hip implants. J Biomed Mater Res B Appl Biomater 2020; 108:1213-1228. [DOI: 10.1002/jbm.b.34470] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/18/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023]
Affiliation(s)
- Qiong Wang
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| | - Felipe Eltit
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| | - Donald Garbuz
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Clive Duncan
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Bassam Masri
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Nelson Greidanus
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Rizhi Wang
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| |
Collapse
|
18
|
Noli F, Papadopoulos P, Kolias P, Tsiridis E, Papavasiliou K, Sayegh F. Neutron activation analysis for determination of metal ions in biological fluids of patients after CoCrMo arthroplasty. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06718-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
19
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
20
|
Kovochich M, Finley BL, Novick R, Monnot AD, Donovan E, Unice KM, Fung ES, Fung D, Paustenbach DJ. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review. Crit Rev Toxicol 2019; 48:853-901. [DOI: 10.1080/10408444.2018.1563048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Römmelt C, Munsch T, Drynda A, Lessmann V, Lohmann CH, Bertrand J. Periprosthetic hypoxia as consequence of TRPM7 mediated cobalt influx in osteoblasts. J Biomed Mater Res B Appl Biomater 2018; 107:1806-1813. [PMID: 30508321 DOI: 10.1002/jbm.b.34273] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 08/03/2018] [Accepted: 10/07/2018] [Indexed: 01/05/2023]
Abstract
The reasons for the high number of loosened metal-on-metal (MoM) hip implants are still not fully understood. Hypoxia-inducible factor 1 (HIF-1) mediated signaling pathways, which normally modulate tissue metabolism under hypoxic circumstances, could be triggered by metallic wear debris and influence bone metabolism favoring osteolysis. This may lead to early loosening of the orthopedic implants. Immunhistochemical staining of periprosthetic tissues of failed artificial hip implants showed that the concentration of HIF-1α in the surrounding tissues of failed MoM hip implants was significantly higher in comparison to failed metal-on-polyethylene (MoP) hip implants and osteoarthritic tissues. Therefore, we examined the Co2+ -uptake mechanisms and the influence of Co2+ uptake on HIF-1α stabilization. Based on cobalt mediated quenching effects, calcium imaging experiments using fura-2 showed a concentration-dependent cobalt influx in MG-63 cells, which could be inhibited by the unspecific TRPM7 channel inhibitor 2-APB (20 μM) and TRPM7 specific siRNA. Western blots confirmed a dose dependent increase of HIF-1α upon stimulation with Co2+ . This effect could be abrogated by inhibition of cobalt influx using 2-APB. This study shows that chemical hypoxia originating from HIF-1α upregulation within the periprosthetic tissue is related to cobalt wear debris and highlights TRPM7 as an important key mediator in this context. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1806-1813, 2019.
Collapse
Affiliation(s)
- Constantin Römmelt
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| | - Thomas Munsch
- Institute of Physiology, Otto-von-Guericke University, 39120, Magdeburg, Germany.,Center for Behavioral Brain Sciences (CBBS), 39120, Magdeburg, Germany
| | - Andreas Drynda
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| | - Volkmar Lessmann
- Institute of Physiology, Otto-von-Guericke University, 39120, Magdeburg, Germany.,Center for Behavioral Brain Sciences (CBBS), 39120, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| |
Collapse
|
22
|
Abstract
RATIONALE Due to the low incidence and lack of effective diagnostic measures for the diagnosis of metal allergy in patients undergoing total joint arthroplasty (TJA), diagnosis relies mainly on the exclusion of other causes, in particular infection. It remains a relatively unpredictable and poorly understood cause of implant failure. At present, skin patch testing, leukocyte migration inhibition test (LMIT) and lymphocyte transformation tests (LTT) are being commonly used to assess metal hypersensitivity.This report presents both a case and literature review. PATIENT CONCERNS A 61-year-old female patient experienced continuous swelling and pain in the right knee joint for 9 months after a right-side total knee arthroplasty (TKA). DIAGNOSES We believe this is the case report of metal allergy in TKA. The following were the reasons for this. First, no definite symptoms of infection during revision arthroplasty were observed, but with obvious hyperplasia of synovium. Furthermore, a frozen biopsy revealed an extremely low neutrophil count, which was considered to be caused by chronic inflammation. Second, the results of repeated post-operation reexaminations indicate a clear increase in the number of eosinophils, while no bacteria were found in the tissue bacterial smear performed during the operation. Third, improvements were clearly observed in the patient following synovectomy, revision of the polyethylene insert and anti-anaphylactic treatment. INTERVENTIONS The patient underwent synovectomy, revision of the polyethylene insert and anti-anaphylactic treatment. OUTCOMES The patient's right knee remained mildly swollen; however, the pain has been relieved significantly. The range of motion could achieve 0 degrees of extension and 90 degrees of flexion. LESSONS No consensus has been reached about the best diagnostic criteria for this disease, and most physicians would consider it to be a possibility when other diseases including periprosthetic joint infection (PJI) have been excluded. Although this case followed the same course, the outcome following synovectomy and anti-anaphylactic treatment further confirmed our hypothesis.
Collapse
|
23
|
Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases. Clin Orthop Relat Res 2018; 476:1441-1451. [PMID: 29698302 PMCID: PMC6259674 DOI: 10.1097/01.blo.0000533617.64678.69] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND There are four distinguishable types of THA devices in wide use, as defined by the femoral and acetabular bearing surfaces: metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). Metallic head THAs (MoP and MoM) can potentially induce cardiac toxicity because cobalt species, generated at the head-neck trunnion, and in the case of MoM devices, at the articular surface as well, can be absorbed systemically. However, studies have provided inconsistent results. QUESTIONS/PURPOSES The purpose of this study was to assess the risk of dilated cardiomyopathy (DCM) or heart failure (HF) associated with metallic head THAs using data from the French national health insurance databases. METHODS Between 2008 and 2011 in France, 399,968 patients ≥ 55 years had a first THA. A total of 127,481 were excluded after we applied the exclusion criteria regarding arthroplasty and 17,137 as a result of a history of DCM/HF, recorded in the French national health insurance reimbursement databases, between January 1, 2006, and the date of inclusion. The final cohort included 255,350 individuals (43% men; mean age 72 ± 9 years). Of them, 93,581 (37%) had been implanted with MoP, 58,095 (23%) with CoP, 11,298 (4%) with MoM, and 92,376 (36%) with CoC THAs. Patients were followed until December 2015. Patients with incident DCM/HF were identified by a new entitlement to the long-term disease scheme or a first hospitalization with a diagnosis of DCM or HF. MoP and CoP THAs are generally implanted in old patients, whereas MoM and CoC are mostly indicated in young, active male patients. Thus, to consider the specific indications of the bearing couples, analyses were separately performed in two distinct subcohorts, one comprising patients with MoP or CoP and one comprising patients with MoM or CoC THA. In each subcohort, the DCM/HF risk was compared between patients with metallic head versus nonmetallic head THAs (MoP versus CoP, MoM versus CoC). Hazard ratios (adjusted HRs) of incident DCM/HF were estimated using Cox models adjusted for baseline sex, age, THA characteristics (fixation technique with cement, use of a modular femoral neck), and comorbidities at baseline. Cox models were stratified by sex and age. RESULTS The crude incidence of DCM/HF per 100 person-years was 2.4 in patients with MoP, 1.8 with CoP, 1.2 with MoM, and 1.1 with CoC THAs. Overall, metallic head THAs were associated with a slight increase in DCM/HF risk (MoP versus CoP: adjusted HR, 1.08; 95% confidence interval [CI], 1.05-1.12; p < 0.001; MoM versus CoC: adjusted HR, 1.11; 95% CI, 1.03-1.19; p = 0.007). In the MoM-CoC subcohort, the risk tended to be more pronounced with MoM versus CoC THAs in women (MoM versus CoC: adjusted HR, 1.20; 95% CI, 1.07-1.35; p = 0.002) and patients aged ≥ 75 years (MoM versus CoC: adjusted HR, 1.16; 95% CI, 1.04-1.29; p = 0.009). CONCLUSIONS Metallic head THAs were associated with a slightly increased DCM/HF risk, especially with MoM in women and older patients. Some caveats should be mentioned: severity of DCM or HF was not available and residual confounding cannot be ruled out despite considering many covariates. Our findings suggest that cardiac function should be regularly monitored in patients with metallic head THAs. Further investigations should be planned on large international cohorts. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|
24
|
Nahidh M, Garma NM, Jasim ES. Assessment of Ions released from Three Types of Orthodontic Brackets immersed in Different Mouthwashes: An in vitro Study. J Contemp Dent Pract 2018; 19:73-80. [PMID: 29358538 DOI: 10.5005/jp-journals-10024-2214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIM Herbs are used widely in medicine. The purpose of the present study was to assess the ion release from gold-plated orthodontic bracket compared with other stainless steel brackets, and based on the findings of the study, the orthodontists can choose the most biocompatible brackets and mouthwashes useful in the clinical practice. MATERIALS AND METHODS A total of 150 orthodontic brackets from Orthotechnology™ Company, USA (50 stainless steel one-piece brackets, 50 stainless steel two-piece brackets, and 50 gold brackets) were immersed in four mouthwashes in addition to distilled water. Ten of each type of brackets in every media were immersed under 37°C for 45 days. Ions released in these mouthwashes were measured, and comparisons among different bracket types and among various mouthwashes were done by one-way analysis of variance (ANOVA) and then with Games-Howell tests. RESULTS Increased amounts of ions released in herbal mouth-washes were recorded in gold and two-piece brackets in comparison with one-piece stainless steel brackets. CONCLUSION Herbal mouthwashes must be used with caution as they showed an increased amount of ions released in comparison with chlorhexidine. One-piece stainless steel bracket system is the most compatible bracket type, as they released the least amount of ions. CLINICAL SIGNIFICANCE One-piece stainless steel brackets are better than two-piece brackets in terms of ions released.
Collapse
Affiliation(s)
- Mohammed Nahidh
- Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq, Phone: +009647702551616, e-mail:
| | - Noor Mh Garma
- Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| | - Esraa S Jasim
- Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| |
Collapse
|
25
|
Yilgor C, Efendiyev A, Akbiyik F, Demirkiran G, Senkoylu A, Alanay A, Yazici M. Metal Ion Release During Growth-Friendly Instrumentation for Early-Onset Scoliosis: A Preliminary Study. Spine Deform 2018; 6:48-53. [PMID: 29287817 DOI: 10.1016/j.jspd.2017.06.005] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 05/01/2017] [Accepted: 06/18/2017] [Indexed: 11/16/2022]
Abstract
BACKGROUND Metal ions released from spinal instruments can cause localized debris and distribute systemically to settle on distant organs. Children with early-onset deformities live with metallic implants for a substantial amount of time. No research focused on metal distribution in growth-friendly instrumentations. The aim of this study was to compare age-matched growing rod (GR) and magnetically controlled growing rod (MCGR) groups to noninstrumented controls. METHODS The study was designed as a multicenter, prospective, cross-sectional case series. GR and MCGR applications of three institutions were included. A total of 52 children were enrolled. Blood samples were collected between December 2014 and February 2015. Biochemical serum analyses were performed to trace and quantify titanium, vanadium, aluminum, and boron. The GR group included 15 children. Mean age was 10.7 (range 6-15). MCGR group included 22 children. Mean age was 8.5 (range 2-13). Fifteen age-matched nonoperated children formed the control group. The mean age was 10.4 (range 5-15). One-way analysis of variance, Kruskal-Wallis, and Mann-Whitney U tests were used for comparisons. RESULTS The mean serum titanium level in control, GR, and MCGR groups were 2.8 ± 1.4, 7.3 ± 4.3, and 10.2 ± 6.8 μg/L, respectively. GR and MCGR group titanium levels were higher than controls' (p = .008 and p < .001). The mean serum vanadium level in control, GR, and MCGR groups were 0.2 ± 0.0, 0.2 ± 0.0, and 0.5 ± 0.5 μg/L, respectively. MCGR group vanadium level was higher than control (p < .001) and GR groups (p = .004). Mean serum levels in control, GR, and MCGR groups were, respectively, 5.4 ± 4.1, 8.1 ± 7.4, and 7.8 ± 5.1 μg/L for aluminum and 86.7 ± 2.7, 86.9 ± 2.5, and 85.0 ± 6.6 μg/L for boron. The distribution of aluminum and boron were similar across groups (p = .675 and p = .396). CONCLUSIONS Both GR and MCGR applications significantly release titanium and possibly aluminum. MCGR further releases vanadium. MCGR possibly releases more titanium than traditional GR. Time-dependent alterations of serum ion levels, structural properties of the MCGR device, and exposure caused by magnetic distraction processes warrant investigation.
Collapse
Affiliation(s)
- Caglar Yilgor
- Orthopedics and Traumatology, Acibadem Mehmet Ali Aydınlar University, İçerenköy Mh. No:32 Kerem Aydınlar Kampüsü, Kayışdağı Cd., 34752 Ataşehir, Turkey
| | - Ayaz Efendiyev
- Orthopedics and Traumatology, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
| | - Filiz Akbiyik
- Medical Biochemistry, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
| | - Gokhan Demirkiran
- Orthopedics and Traumatology, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
| | - Alpaslan Senkoylu
- Orthopedics and Traumatology, Gazi University, Emniyet Mahallesi, 06560 Yenimahalle, Ankara, Turkey
| | - Ahmet Alanay
- Orthopedics and Traumatology, Acibadem Mehmet Ali Aydınlar University, İçerenköy Mh. No:32 Kerem Aydınlar Kampüsü, Kayışdağı Cd., 34752 Ataşehir, Turkey
| | - Muharrem Yazici
- Orthopedics and Traumatology, Hacettepe University, 06100 Sihhiye, Ankara, Turkey.
| |
Collapse
|
26
|
Toh WQ, Tan X, Bhowmik A, Liu E, Tor SB. Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review. MATERIALS 2017; 11:ma11010030. [PMID: 29278375 PMCID: PMC5793528 DOI: 10.3390/ma11010030] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 12/12/2017] [Accepted: 12/22/2017] [Indexed: 11/20/2022]
Abstract
Orthopedic implants first started out as an all-metal hip joint replacement. However, poor design and machinability as well as unsatisfactory surface finish subjected the all-metal joint replacement to being superseded by a polyethylene bearing. Continued improvement in manufacturing techniques together with the reality that polyethylene wear debris can cause hazardous reactions in the human body has brought about the revival of metal-on-metal (MOM) hip joints in recent years. This has also led to a relatively new research area that links tribology and corrosion together. This article aims at reviewing the commonly used tribochemical methods adopted in the analysis of tribocorrosion and putting forward some of the models and environmental factors affecting the tribocorrosive behavior of CoCrMo alloys, a widely-used class of biomaterial for orthopedic implants.
Collapse
Affiliation(s)
- Wei Quan Toh
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| | - Xipeng Tan
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| | - Ayan Bhowmik
- Rolls-Royce@NTU Corporate Lab, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| | - Erjia Liu
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| | - Shu Beng Tor
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
| |
Collapse
|
27
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
28
|
Forsthoefel CW, Brown NM, Barba ML. Comparison of metal ion levels in patients with hip resurfacing versus total hip arthroplasty. J Orthop 2017; 14:561-564. [PMID: 28878517 DOI: 10.1016/j.jor.2017.07.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 07/21/2017] [Indexed: 12/17/2022] Open
Abstract
Mechanical wear at the articular surface and corrosive processes at modular junctions, such as the trunnion, are responsible for metal ions production. We retrospectively reviewed 64 patients who underwent THA with a metal on metal bearing surface and 34 patients with hip Resurfacing. Metal ion measurements, six-week post-op radiographs, and functional scores were included in the analysis. Cobalt ion levels were significantly elevated in THA patients, 2.95 μg/L as compared to resurfacing patients, (2.95 versus 1.30 μg/L, p < 0.0005). Chromium levels were not significantly different between THA patients and resurfacing patients (1.05 versus 1.00 μg/L, p = 0.529).
Collapse
Affiliation(s)
- Craig W Forsthoefel
- Department of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Nicholas M Brown
- Department of Orthopedic Surgery, Rush University, Chicago, IL, USA
| | | |
Collapse
|
29
|
Vogel D, Falkenberg A, Bierbaum S, Schulze C, Bader R, Kluess D. Mechanical Stability of the Taper Connection of Large Metal Femoral Heads With Adapter Sleeves in Total Hip Arthroplasty Analyzed Using Explicit Finite Element Simulations. J Arthroplasty 2017; 32:2580-2586. [PMID: 28416253 DOI: 10.1016/j.arth.2017.03.033] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 02/28/2017] [Accepted: 03/13/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Large diameter heads (LDHs) of metal-on-metal bearings in total hip arthroplasty provide increased range of motion and reduced dislocation rates. However, major concerns grew over high wear rates from the modular connection between femoral stem and head, especially in combination with adapter sleeves. METHODS A computational study on the taper connection stability of LDH (50 mm) with adapter sleeves of different lengths (S, M, L, and XL) compared with a standard femoral head (32 mm) without adapter sleeves was conducted using explicit finite element analyses. Four different impact configurations were considered resulting from varied mallet mass (0.5 vs 1.0 kg) and velocity (1.0 vs 2.0 m/s). The taper stability was evaluated by determination of the pull-off forces and micromotions due to simulated joint loads during walking (2 kN and 7.9 Nm, respectively). Moreover, the deformations of the adapter sleeves and the contact area in the taper connections were evaluated. RESULTS Although the pull-off forces of the LDH with different-sized adapter sleeves were comparable, contact area decreased and adapter sleeve deformations increased (up to 283%) with an increasing adapter sleeve length. Moreover, the micromotions of LDH with adapter sleeves were up to 7-times higher, as compared with the standard femoral head without an adapter sleeve. CONCLUSION The present numerical study confirms that the assembly technique of LDH with adapter sleeves reveals increased micromotions compared with standard femoral head sizes. We could demonstrate that deviations of the stem trunnion geometry and improper surgical instructions led to worse mechanical stability of the taper connection.
Collapse
Affiliation(s)
- Danny Vogel
- Department of Orthopaedics, Biomechanics and Implant Technology Research Laboratory, University Medicine Rostock, Rostock, Germany
| | - Adrian Falkenberg
- Department of Orthopaedics, Biomechanics and Implant Technology Research Laboratory, University Medicine Rostock, Rostock, Germany; Institute of Biomechanics, School of Mechanical Engineering, Hamburg University of Technology, Hamburg, Germany
| | - Sarah Bierbaum
- Department of Orthopaedics, Biomechanics and Implant Technology Research Laboratory, University Medicine Rostock, Rostock, Germany
| | - Christian Schulze
- Department of Orthopaedics, Biomechanics and Implant Technology Research Laboratory, University Medicine Rostock, Rostock, Germany
| | - Rainer Bader
- Department of Orthopaedics, Biomechanics and Implant Technology Research Laboratory, University Medicine Rostock, Rostock, Germany
| | - Daniel Kluess
- Department of Orthopaedics, Biomechanics and Implant Technology Research Laboratory, University Medicine Rostock, Rostock, Germany
| |
Collapse
|
30
|
Kishimoto Y, Asakawa S, Sato T, Takano T, Nakajyo T, Mizuno N, Segawa R, Yoshikawa T, Hiratsuka M, Yanai K, Ohtsu H, Hirasawa N. Induced histamine regulates Ni elution from an implanted Ni wire in mice by downregulating neutrophil migration. Exp Dermatol 2017; 26:868-874. [PMID: 28191674 DOI: 10.1111/exd.13315] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/02/2017] [Indexed: 12/18/2022]
Abstract
Histamine regulates various inflammatory reactions. We have reported that the expression of histidine decarboxylase (HDC) was induced by subcutaneous implantation of nickel (Ni) wire. However, the source and functions of histamine in Ni elution and Ni wire-induced inflammation have not been completely studied. We aimed to elucidate the effects of de novo synthesized histamine on leucocyte infiltration and Ni elution. Implantation of Ni wire induced an increase in the Ni ion content of the surrounding tissues and serum and in the mRNA levels of HDC, a histamine-producing enzyme, macrophage inflammatory protein-2 (MIP-2), a chemoattractant for neutrophils, and monocyte chemoattractant protein-1 (MCP-1), a chemoattractant for monocytes. The Ni wire induced HDC expression even in mast cell-deficient WBB6F1-W/WV mice. In HDC knockout (HDC KO) mice, the Ni wire-induced increase in MIP-2 mRNA expression was significantly higher than that in wild-type mice but not MCP-1. MIP-2 expression was enhanced in histamine H2 receptor knockout (H2R KO) mice but not in WBB6F1-W/WV mice. Histamine inhibited NiCl2 -induced MIP-2 mRNA expression in mouse bone marrow-derived macrophages (BMDMs) obtained from wild-type mice; this inhibition was not observed in BMDMs from H2R KO mice. Ni elution increased in HDC KO mice, in which leucocyte infiltration also increased, and was suppressed in mice treated with neutrophil-specific antibody. These results suggest that the Ni wire induced HDC expression in non-mast cells and that, in the chronic phase of inflammation, endogenous histamine reduced Ni elution, probably through regulation of MIP-2 expression and neutrophil migration.
Collapse
Affiliation(s)
- Yu Kishimoto
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Sanki Asakawa
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Taiki Sato
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Takayuki Takano
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Takahisa Nakajyo
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Natsumi Mizuno
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Ryosuke Segawa
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| | - Takeo Yoshikawa
- Department of Pharmacology, Graduate School of Medicine, Tohoku University, Sendai, Japan
| | - Masahiro Hiratsuka
- Department of Pharmacology, Graduate School of Medicine, Tohoku University, Sendai, Japan
| | - Kazuhiko Yanai
- Department of Pharmacology, Graduate School of Medicine, Tohoku University, Sendai, Japan
| | - Hiroshi Ohtsu
- Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
| | - Noriyasu Hirasawa
- Laboratory of Pharmacotherapy of Life-style Related Diseases, Graduate School of Pharmaceutical Sciences, Tohoku University, Sendai, Japan
| |
Collapse
|
31
|
Calistri A, Campbell P, Van Der Straeten C, De Smet KA. Hip resurfacing arthroplasty complicated by mismatched implant components. World J Orthop 2017; 8:286-289. [PMID: 28361022 PMCID: PMC5359765 DOI: 10.5312/wjo.v8.i3.286] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2016] [Revised: 08/21/2016] [Accepted: 12/28/2016] [Indexed: 02/06/2023] Open
Abstract
Metal-on-metal hip resurfacing has gained popularity as a feasible treatment option for young and active patients with hip osteoarthritis and high functional expectations. This procedure should only be performed by surgeons who have trained specifically in this technique. Preoperative planning is essential for hip resurfacing in order to execute a successful operation and preview any technical problems. The authors present a case of a man who underwent a resurfacing arthroplasty for osteoarthritis of the left hip that was complicated by mismatched implant components that were revised three days afterwards for severe pain and leg length discrepancy. Such mistakes, although rare, can be prevented by educating operating room staff in the size and colour code tables provided by the companies on their prostheses or implant boxes.
Collapse
|
32
|
Smith JT, Schneider AD, Katchko KM, Yun C, Hsu EL. Environmental Factors Impacting Bone-Relevant Chemokines. Front Endocrinol (Lausanne) 2017; 8:22. [PMID: 28261155 PMCID: PMC5306137 DOI: 10.3389/fendo.2017.00022] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 01/25/2017] [Indexed: 01/07/2023] Open
Abstract
Chemokines play an important role in normal bone physiology and the pathophysiology of many bone diseases. The recent increased focus on the individual roles of this class of proteins in the context of bone has shown that members of the two major chemokine subfamilies-CC and CXC-support or promote the formation of new bone and the remodeling of existing bone in response to a myriad of stimuli. These chemotactic molecules are crucial in orchestrating appropriate cellular homing, osteoblastogenesis, and osteoclastogenesis during normal bone repair. Bone healing is a complex cascade of carefully regulated processes, including inflammation, progenitor cell recruitment, differentiation, and remodeling. The extensive role of chemokines in these processes and the known links between environmental contaminants and chemokine expression/activity leaves ample opportunity for disruption of bone healing by environmental factors. However, despite increased clinical awareness, the potential impact of many of these environmental factors on bone-related chemokines is still ill defined. A great deal of focus has been placed on environmental exposure to various endocrine disruptors (bisphenol A, phthalate esters, etc.), volatile organic compounds, dioxins, and heavy metals, though mainly in other tissues. Awareness of the impact of other less well-studied bone toxicants, such as fluoride, mold and fungal toxins, asbestos, and chlorine, is also reviewed. In many cases, the literature on these toxins in osteogenic models is lacking. However, research focused on their effects in other tissues and cell lines provides clues for where future resources could be best utilized. This review aims to serve as a current and exhaustive resource detailing the known links between several classes of high-interest environmental pollutants and their interaction with the chemokines relevant to bone healing.
Collapse
Affiliation(s)
- Justin T. Smith
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, IL, USA
| | - Andrew D. Schneider
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, IL, USA
| | - Karina M. Katchko
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, IL, USA
| | - Chawon Yun
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, IL, USA
| | - Erin L. Hsu
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, IL, USA
- *Correspondence: Erin L. Hsu,
| |
Collapse
|
33
|
Akhtar A, Kazi TG, Afridi HI, Musharraf SG, Talpur FN, Khan N, Bilal M, Khan M. Vortex-assisted ionic liquid-based dispersive liquid-liquid microextraction for assessment of chromium species in artificial saliva extract of different chewing tobacco products. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:25288-25298. [PMID: 27696158 DOI: 10.1007/s11356-016-7700-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 09/12/2016] [Indexed: 06/06/2023]
Abstract
A novel dispersive liquid-liquid microextraction (ILDLLμE) method using an extracting solvent (ionic liquid) and dispersant (Triton X-114) was developed for the separation and preconcentration of hexavalent chromium (Cr6+) in artificial saliva extract (ASE) of chewing tobacco products, gutkha, and mainpuri (n = 23). In the proposed method, the extraction of Cr6+ was accomplished by using ammonium pyrrolidinedithiocarbamate (APDC) as complexing agent and 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM] [PF6] as extracting solvent. The tiny droplet of metal chelate was then dispersed into TX-114 emulsion, using vortex mixer. Various parameters such as concentration of APDC, pH of the solution, volume of [C4MIM] [PF6], and TX-114 as well as extraction time were studied. Under the most favorable conditions, the limit of detection was found to be 0.068 μg/L with the relative standard deviation <5 %. The enrichment factor of developed method was found as 62.5, and method has been effectively applied for the analysis of Cr species in artificial saliva extract of gutkha and mainpuri products. The Cr6+ was quantitatively recovered (<97 %) under optimal conditions, while the recovery of trivalent specie (Cr3+), at the same experimental conditions, was observed to be <5 %. The Cr3+ was determined by the difference of total Cr and Cr6+ in artificial saliva extract of selected STP. Health risks associated with the intake of total Cr in gutkha and mainpuri were assessed in terms of estimated daily intake, such as carcinogenic and noncarcinogenic risks. Estimated daily intake of Cr via chewing 10 g/day of gutkha and mainpuri was found to be below the maximum tolerable daily intake, whereas the calculated risk of cancer for Cr was observed in the acceptable range of 10E-6-10E-4, except some brands of gutkha. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Asma Akhtar
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan.
| | - Tasneem Gul Kazi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Hassan Imran Afridi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Syed Ghulam Musharraf
- H. E.J. Research Institute of Chemistry, University of Karachi, Karachi, 75270, Pakistan
| | - Farah Naz Talpur
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Noman Khan
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Muhammad Bilal
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Mustafa Khan
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| |
Collapse
|
34
|
Prosthetic and Device Surgery Considerations. CURRENT TREATMENT OPTIONS IN ALLERGY 2016. [DOI: 10.1007/s40521-016-0101-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
35
|
Jauch-Matt SY, Miles AW, Gill HS. Effect of trunnion roughness and length on the modular taper junction strength under typical intraoperative assembly forces. Med Eng Phys 2016; 39:94-101. [PMID: 27913177 DOI: 10.1016/j.medengphy.2016.11.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2016] [Revised: 10/15/2016] [Accepted: 11/13/2016] [Indexed: 01/24/2023]
Abstract
Modular hip implants are at risk of fretting-induced postoperative complications most likely initiated by micromotion between adjacent implant components. A stable fixation between ball head and stem-neck taper is critical to avoid excessive interface motions. Therefore, the aim of this study was to identify the effect of trunnion roughness and length on the modular taper strength under typical intraoperative assembly forces. Custom-made Titanium trunnions (standard/mini taper, smooth/grooved surface finish) were assembled with modular Cobalt-chromium heads by impaction with peak forces ranging from 2kN to 6kN. After each assembly process these were disassembled with a materials testing machine to detect the pull-off force as a measure for the taper strength. As expected, the pull-off forces increased with rising peak assembly force (p < 0.001). For low and moderate assembly forces, smooth standard tapers offered higher pull-off forces compared to grooved tapers (p < 0.038). In the case of an assembly force of 2kN, mini tapers showed a higher taper strength than standard ones (p=0.037). The results of this study showed that smooth tapers provided a higher strength for taper junctions. This higher taper strength may reduce the risk of fretting-related complications especially in the most common range of intraoperative assembly forces.
Collapse
Affiliation(s)
- S Y Jauch-Matt
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| | - A W Miles
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| | - H S Gill
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| |
Collapse
|
36
|
Abstract
Corrosion of metallic implants in contact with body fluids is unavoidable, especially at interfaces where movement occurs or in gaps. Corrosion became clinically relevant with the introduction of large modular metal-on-metal total hip joint articulations (MoM THA) early in the 21st century. This review attempts to summarise the scientific knowledge about taper problems available at the time of introduction of these bearings, why this "disaster" could happen. It is speculated that changes to the taper connection made in the 1990s to increase the range of motion with small heads (28 and 32 mm) reduced the mechanical strength of this connection, which did not matter for small heads. With the use of large and very large metal heads in MoM articulations, which have a larger lever arm and can generate high friction in unfavourable situations, suddenly the taper interface exhibited corrosion problems on a previously unknown scale. It is speculated that due to the higher mechanical loading with larger heads, the taper connection became less forgiving with respect to assembly conditions, contamination, manufacturing tolerances and other factors, which are yet not known. Since no major clinical problems had been reported before the introduction of these bearings and the pre-clinical testing was very successful, the disaster took its course. The patient-implant-surgeon system is a very complex intrinsically hazardous system. Pre-clinical testing addresses few and defined factors and such, good results cannot be directly transferred to the clinical reality. A controlled stepwise introduction of innovations is required.
Collapse
|
37
|
Gibon E, Amanatullah DF, Loi F, Pajarinen J, Nabeshima A, Yao Z, Hamadouche M, Goodman SB. The biological response to orthopaedic implants for joint replacement: Part I: Metals. J Biomed Mater Res B Appl Biomater 2016; 105:2162-2173. [PMID: 27328111 DOI: 10.1002/jbm.b.33734] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 04/19/2016] [Accepted: 06/01/2016] [Indexed: 12/12/2022]
Abstract
Joint replacement is a commonly performed, highly successful orthopaedic procedure, for which surgeons have a large choice of different materials and implant designs. The materials used for joint replacement must be both biologically acceptable to minimize adverse local tissue reactions, and robust enough to support weight bearing during common activities of daily living. Modern joint replacements are made from metals and their alloys, polymers, ceramics, and composites. This review focuses on the biological response to the different biomaterials used for joint replacement. In general, modern materials for joint replacement are well tolerated by the body as long as they are in bulk (rather than in particulate or ionic) form, are mechanically stable and noninfected. If the latter conditions are not met, the prosthesis will be associated with an acute/chronic inflammatory reaction, peri-prosthetic osteolysis, loosening and failure. This article (Part 1 of 2) is dedicated to the use of metallic devices in orthopaedic surgery including the associated biological response to metallic byproducts is a review of the basic science literature regarding this topic. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2162-2173, 2017.
Collapse
Affiliation(s)
- Emmanuel Gibon
- Department of Orthopaedic Surgery, Stanford University, Stanford, California.,Laboratoire de Biomécanique et Biomatériaux Ostéo-Articulaires - UMR CNRS 7052, Faculté de Médecine - Université Paris7, Paris, France.,Department of Orthopaedic Surgery, Hopital Cochin, APHP, Université Paris5, Paris, France
| | - Derek F Amanatullah
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Florence Loi
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Jukka Pajarinen
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Akira Nabeshima
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Zhenyu Yao
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Moussa Hamadouche
- Department of Orthopaedic Surgery, Hopital Cochin, APHP, Université Paris5, Paris, France
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| |
Collapse
|
38
|
Paukkeri EL, Korhonen R, Hämäläinen M, Pesu M, Eskelinen A, Moilanen T, Moilanen E. The Inflammatory Phenotype in Failed Metal-On-Metal Hip Arthroplasty Correlates with Blood Metal Concentrations. PLoS One 2016; 11:e0155121. [PMID: 27227536 PMCID: PMC4882013 DOI: 10.1371/journal.pone.0155121] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Accepted: 04/25/2016] [Indexed: 12/12/2022] Open
Abstract
INTRODUCTION Hip arthroplasty is the standard treatment of a painful hip destruction. The use of modern metal-on-metal (MOM) bearing surfaces gained popularity in total hip arthroplasties during the last decade. Recently, worrisome failures due to adverse reaction to metal debris (ARMD), including pseudotumor response, have been widely reported. However, the pathogenesis of this reaction remains poorly understood. The aim of the present study was to investigate the ARMD response by flow cytometry approach. METHODS Sixteen patients with a failed Articular Surface Replacement (ASR) hip prosthesis were included in the study. Samples of pseudotumor tissues collected during revision surgery were degraded by enzyme digestion and cells were typed by flow cytometry. Whole blood chromium and cobalt concentrations were analyzed with mass spectrometry before revision surgery. RESULTS Flow cytometry analysis showed that the peri-implant pseudotumor tissue expressed two principal phenotypes, namely macrophage-dominated and T-lymphocyte-dominated response; the average portions being 54% (macrophages) and 25% (T-lymphocytes) in macrophage-dominated inflammation and 20% (macrophages) and 54% (T-lymphocytes) in T-lymphocyte-dominated response. The percentages of B-lymphocytes and granulocytes were lower in both phenotypes. Interestingly, the levels of blood chromium and cobalt were significantly higher in patients with macrophage-dominated response. CONCLUSIONS The results suggest that the adverse tissue reactions induced by MOM wear particles contain heterogeneous pathogeneses and that the metal levels are an important factor in the determination of the inflammatory phenotype. The present results support the hypothesis that higher metal levels cause cytotoxicity and tissue injury and macrophages are recruited to clear the necrotic debris. On the other hand, the adverse response developed in association with lower metal levels is T-lymphocyte-dominated and is likely to reflect hypersensitivity reaction.
Collapse
Affiliation(s)
- Erja-Leena Paukkeri
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| | - Riku Korhonen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| | - Mari Hämäläinen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| | - Marko Pesu
- Immunoregulation, Institute of Biomedical Technology, University of Tampere, Tampere, Finland.,Department of Dermatology, Tampere University Hospital, Tampere, Finland
| | | | - Teemu Moilanen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland.,Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Eeva Moilanen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| |
Collapse
|
39
|
Examination of a biodegradable magnesium screw for the reconstruction of the anterior cruciate ligament: A pilot in vivo study in rabbits. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 59:1100-1109. [PMID: 26652469 DOI: 10.1016/j.msec.2015.11.037] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 10/28/2015] [Accepted: 11/13/2015] [Indexed: 11/24/2022]
Abstract
The reconstruction of the anterior cruciate ligament is, for the most part, currently performed with interference screws made of titanium or degradable polymers. The aim of this study was to investigate the use of biodegradable magnesium interference screws for such a procedure because of their known biocompatibility and reported osteoconductive effects. The left tibiae of each of 18 rabbits were implanted with a magnesium-based (MgYREZr-alloy) screw, and another 18 with a titanium-based control. Each group was divided into observation periods of 4, 12 and 24weeks. After sacrifice, μCT scans were acquired to assess the amount of the gas liberated and the degradation rate of the implant. Histological evaluations were performed to investigate the local tissue response adjacent to the implant and to assess the status of the attachment between the tendon and the bone tissue. The μCT scans showed that liberation of gas was most prominent 4weeks after implantation and was significantly decreased by 24weeks. All screws remained in situ and formed a sufficient connection with the tendon and sufficient osseous integration at 24weeks. Histological evaluations showed neither inflammatory reactions nor necrosis of the tendon. The results of this pilot study in rabbits indicate that this magnesium-based interference screw should be considered as an alternative to conventional implant materials.
Collapse
|
40
|
Savarino L, Fotia C, Roncuzzi L, Greco M, Cadossi M, Baldini N, Giannini S. Does chronic raise of metal ion levels induce oxidative DNA damage and hypoxia-like response in patients with metal-on-metal hip resurfacing? J Biomed Mater Res B Appl Biomater 2015; 105:460-466. [PMID: 26477446 DOI: 10.1002/jbm.b.33555] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 06/24/2015] [Accepted: 10/03/2015] [Indexed: 02/06/2023]
Abstract
Metal-on-metal hip resurfacing (MOM-HR) represents a viable alternative to traditional arthroplasty. Nevertheless, in MOM coupling both metal nanoparticles and ions are released, whose toxicity remains a matter of concern. We investigated whether 'endogenous' chronic exposure to cobalt and chromium induced a state of oxidative stress, DNA damage and a hypoxia-like response in patients with well-functioning MOM-HR. Twenty-two patients with unilateral MOM-HR were recruited at long-term. Twenty-one osteoarthritic subjects were enrolled for comparison. Serum ion levels were measured and correlated with 8-hydroxydeoxyguanosine and circulating-free-DNA, as markers of oxidative DNA damage. Moreover, the hypoxia-inducible factor-1α, marker of hypoxic state, was evaluated. Ion concentrations were found to be 5-to-15 times higher in MOM-HR patients than in presurgery subjects (p < 0.001); circulating-free-DNA, 8-hydroxydeoxyguanosine, and hypoxia-inducible factor-1α levels were not significantly different between groups and did not correlate with ion levels. Analyzing the results according to gender, MOM-HR males had higher 8-hydroxydeoxyguanosine levels (p = 0.01) compared with MOM-HR females. Similarly, circulating-free-DNA values were higher in males than females, even if this difference did not reach statistical significance. This research is the first that attempted to investigate the long-term effects of ion dissemination in subjects with well-fixed MOM implants. A significant correlation between biomarkers increase and ion levels was not demonstrated. Nevertheless, both circulating-free-DNA and 8-hydroxydeoxyguanosine showed a tendency to increase in MOM-HR males. Further studies with a larger sample size should be performed to detect the clinical relevance of biomarkers increase especially in younger subjects, where a chronic moderately elevated exposure has to be faced. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 460-466, 2017.
Collapse
Affiliation(s)
- Lucia Savarino
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Caterina Fotia
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Laura Roncuzzi
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Michelina Greco
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Matteo Cadossi
- Department I of Orthopaedics and Traumatology, Rizzoli Orthopedic Institute, Bologna, Italy
| | - Nicola Baldini
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy.,Department of Biomedical and Neuromotor Sciences, Bologna University, Bologna, Italy
| | - Sandro Giannini
- Department I of Orthopaedics and Traumatology, Rizzoli Orthopedic Institute, Bologna, Italy.,Department of Biomedical and Neuromotor Sciences, Bologna University, Bologna, Italy
| |
Collapse
|
41
|
Bi F, Shi Z, Zhou C, Liu A, Shen Y, Yan S. Intermittent Administration of Parathyroid Hormone [1-34] Prevents Particle-Induced Periprosthetic Osteolysis in a Rat Model. PLoS One 2015; 10:e0139793. [PMID: 26441073 PMCID: PMC4595472 DOI: 10.1371/journal.pone.0139793] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Accepted: 09/17/2015] [Indexed: 11/19/2022] Open
Abstract
We examined whether intermittent administration of parathyroid hormone [1-34] (PTH[1-34]; 60 μg/kg/day) can prevent the negative effects of titanium (Ti) particles on implant fixation and periprosthetic osteolysis in a rat model. Eighteen adult male rats (12 weeks old, bones still growing) received intramedullary Ti implants in their bilateral femurs; 6 rats from the blank group received vehicle injections, and 12 rats from the control group and PTH treatment group received Ti particle injections at the time of operation and intra-articular injections 2 and 4 weeks postoperatively. Six of the rats that received Ti particles from the PTH group also received PTH[1-34] treatment. Six weeks postoperatively, all specimens were collected for assessment by X-ray, micro-CT, biomechanical, scanning electron microscopy (SEM), and dynamic histomorphometry. A lower BMD, BV/TV, Tb.N, maximal fixation strength, and mineral apposition rate were observed in the control group compared to the blank group, demonstrating that a periprosthetic osteolysis model had been successfully established. Administration of PTH[1-34] significantly increased the bone mineral density of the distal femur, BV/TV, Tb.N, Tb.Th, Tb.Sp, Con.D, SMI, and maximal fixation strength in the PTH group compared to that in the control group. SEM revealed higher bone-implant contact, thicker lamellar bone, and larger trabecular bone area in the PTH group than in the control group. A higher mineral apposition rate was observed in the PTH group compared to both the blank and control groups. These findings imply that intermittent administration of PTH[1-34] prevents periprosthetic osteolysis by promoting bone formation. The effects of PTH[1-34] were evaluated at a suprapharmacological dosage to the human equivalent in rats; therefore, additional studies are required to demonstrate its therapeutic potential in periprosthetic osteolysis.
Collapse
Affiliation(s)
- Fanggang Bi
- Department of Orthopedic Surgery, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Zhongli Shi
- Department of Orthopedic Surgery, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Chenhe Zhou
- Department of Orthopedic Surgery, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - An Liu
- Department of Orthopedic Surgery, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Yue Shen
- Department of Orthopedic Surgery, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Shigui Yan
- Department of Orthopedic Surgery, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
- * E-mail:
| |
Collapse
|
42
|
de Villiers D, Traynor A, Collins SN, Shelton JC. The increase in cobalt release in metal-on-polyethylene hip bearings in tests with third body abrasives. Proc Inst Mech Eng H 2015; 229:611-8. [PMID: 26183804 PMCID: PMC4626785 DOI: 10.1177/0954411915595433] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Accepted: 05/06/2015] [Indexed: 12/12/2022]
Abstract
Hypersensitivity reactions in patients receiving metal-on-metal hip replacements have been attributed to corrosion products as observed by elevated cobalt and chromium ions in the blood. Although the majority of cases are reported in metal-on-metal, incidences of these reactions have been reported in the metal-on-polyethylene patient population. To date, no in vitro study has considered cobalt release for this bearing combination. This study considered four 28 mm and seven 52 mm diameter metal-on-polyethylene bearings tested following ISO standard hip simulator conditions as well as under established abrasive conditions. These tests showed measurable cobalt in all bearings under standard conditions. Cobalt release, as well as polyethylene wear, increased with diameter, increasing from 52 to 255 ppb. The introduction of bone cement particles into the articulation doubled polyethylene wear and cobalt release while alumina particles produced significant damage on the heads demonstrated by cobalt levels of 70,700 ppb and an increased polyethylene wear from a mean value of 9–160 mm3/mc. Cobalt release was indicative of head damage and correlated with polyethylene wear at the next gravimetric interval. The removal of third body particles resulted in continued elevated cobalt levels in the 52 mm diameter bearings tested with alumina compared to standard conditions but the bearings tested with bone cement particles returned to standard levels. The polyethylene wear in the bone cement tested bearings also recovered to standard levels, although the alumina tested bearings continued to wear at a higher rate of 475 mm3/mc. Cobalt release was shown to occur in metal-on-polyethylene bearings indicating damage to the metal head resulting in increased polyethylene wear. While large diameter metal-on-polyethylene bearings may provide an increased range of motion and a reduced dislocation risk, increased levels of cobalt are likely to be released and this needs to be fully considered before being widely adopted.
Collapse
Affiliation(s)
- Danielle de Villiers
- School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | | | | | - Julia C Shelton
- School of Engineering and Materials Science, Queen Mary University of London, London, UK
| |
Collapse
|
43
|
Abstract
BACKGROUND Metal ion release is common following total hip arthroplasty, yet postoperative levels have not been defined for most stems currently used in clinical practice. AIM To assess metal ion release in the serum of patients with well functioning unilateral Exeter V40 primary total hip arthroplasties one year after surgery. METHODS Whole blood chromium and serum cobalt levels were measured in 20 patients following primary total hip arthroplasty with the Exeter V40 stem and a variety of acetabular components one year after surgery. RESULTS Whole blood chromium levels were within the normal range (10-100 nmol/L), with a single mild elevation of serum cobalt (normal <20 nmol/L). CONCLUSIONS In well functioning primary unilateral total hip arthroplasty using the Exeter V40 stem with a variety of acetabular components one year post surgery, whole blood chromium levels are normal and serum cobalt elevations are rare and mild.
Collapse
|
44
|
The inhibition of RANKL-induced osteoclastogenesis through the suppression of p38 signaling pathway by naringenin and attenuation of titanium-particle-induced osteolysis. Int J Mol Sci 2014; 15:21913-34. [PMID: 25464380 PMCID: PMC4284685 DOI: 10.3390/ijms151221913] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 10/30/2014] [Accepted: 11/24/2014] [Indexed: 12/25/2022] Open
Abstract
The aim of this study was to assess the effect of naringenin on osteoclastogenesis and titanium particle-induced osteolysis. Osteolysis from wear-induced particles and aseptic loosening are the most frequent late complications of total joint arthroplasty leading to revision of the prosthesis. Osteolysis during aseptic loosening is most likely due to increased bone resorption by osteoclasts. Through in vitro studies, we demonstrated that naringenin, a naturally occurring flavanone in grapefruit and tomatoes, exerts potent inhibitory effects on the ligand of the receptor activator of nuclear factor-κB (RANKL)-induced osteoclastogenesis and revealed that the mechanism of action of naringenin, which inhibited osteoclastogenesis by suppression of the p38 signaling pathway. Through in vivo studies, we proved that naringenin attenuated titanium particle-induced osteolysis in a mouse calvarial model. In general, we demonstrated that naringenin inhibited osteoclastogenesis via suppression of p38 signaling in vitro and attenuated titanium particle-induced osteolysis in vivo. This study also suggested that naringenin has significant potential for the treatment of osteolysis-related diseases caused by excessive osteoclast formation and activity.
Collapse
|
45
|
Tian B, Jiang T, Shao Z, Zhai Z, Li H, Fan Q, Liu X, Ouyang Z, Tang T, Jiang Q, Zheng M, Dai K, Qin A, Yu Y, Zhu Z. The prevention of titanium-particle-induced osteolysis by OA-14 through the suppression of the p38 signaling pathway and inhibition of osteoclastogenesis. Biomaterials 2014; 35:8937-50. [PMID: 25086794 DOI: 10.1016/j.biomaterials.2014.06.055] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2014] [Accepted: 06/29/2014] [Indexed: 12/29/2022]
Abstract
Wear-particle-induced osteolysis leads to prosthesis loosening, which is one of the most common causes of joint-implant failure, a problem that must be fixed using revision surgery. Thus, a potential treatment for prosthetic loosening is focused on inhibiting osteoclastic bone resorption, which prevents wear-particle-induced osteolysis. In this study, we synthesized a compound named OA-14 (N-(3- (dodecylcarbamoyl)phenyl)-1H-indole-2-carboxamide) and examined how OA-14 affects titanium (Ti)-particle-induced osteolysis and osteoclastogenesis. We report that OA-14 treatment protected against Ti-particle-induced osteolysis in a mouse calvarial model. Interestingly, the number of tartrate-resistant acid phosphatase-positive osteoclasts decreased after treatment with OA-14 in vivo, which suggested that OA-14 inhibits osteoclast formation. To test this hypothesis, we conducted in vitro studies, and our results revealed that OA-14 markedly diminished osteoclast differentiation and osteoclast-specific gene expression in a dose- and time-dependent manner. Moreover, OA-14 suppressed osteoclastic bone resorption and F-actin ring formation. Furthermore, we determined that OA-14 inhibited osteoclastogenesis by specifically blocking the p38-Mitf-c-fos-NFATc1 signaling cascade induced by RANKL (ligand of receptor activator of nuclear factor κB). Collectively, our results suggest that the compound OA-14 can be safely used for treating particle-induced peri-implant osteolysis and other diseases caused by excessive osteoclast formation and function.
Collapse
Affiliation(s)
- Bo Tian
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Tao Jiang
- The Center of Diagnosis and Treatment for Joint Disease, Drum Tower Clinical Medical College of Nanjing Medical University, Jiangsu, PR China
| | - Zhanying Shao
- College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, PR China
| | - Zanjing Zhai
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Haowei Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Qiming Fan
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Xuqiang Liu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Zhengxiao Ouyang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Tingting Tang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Qing Jiang
- The Center of Diagnosis and Treatment for Joint Disease, Drum Tower Clinical Medical College of Nanjing Medical University, Jiangsu, PR China
| | - Minghao Zheng
- Centre for Orthopaedic Research, School of Surgery, The University of Western Australia, Perth, Australia
| | - Kerong Dai
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - An Qin
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China; Centre for Orthopaedic Research, School of Surgery, The University of Western Australia, Perth, Australia.
| | - Yongping Yu
- College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, PR China.
| | - Zhenan Zhu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China.
| |
Collapse
|
46
|
Liu X, Qu X, Wu C, Zhai Z, Tian B, Li H, Ouyang Z, Xu X, Wang W, Fan Q, Tang T, Qin A, Dai K. The effect of enoxacin on osteoclastogenesis and reduction of titanium particle-induced osteolysis via suppression of JNK signaling pathway. Biomaterials 2014; 35:5721-30. [DOI: 10.1016/j.biomaterials.2014.04.006] [Citation(s) in RCA: 81] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Accepted: 04/01/2014] [Indexed: 02/07/2023]
|
47
|
Matusiewicz H. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. Acta Biomater 2014; 10:2379-403. [PMID: 24565531 DOI: 10.1016/j.actbio.2014.02.027] [Citation(s) in RCA: 124] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 02/13/2014] [Indexed: 02/06/2023]
Abstract
Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included.
Collapse
|
48
|
Chen Z, Wang Z, Wang Q, Cui W, Liu F, Fan W. Changes in early serum metal ion levels and impact on liver, kidney, and immune markers following metal-on-metal total hip arthroplasty. J Arthroplasty 2014; 29:612-6. [PMID: 23993737 DOI: 10.1016/j.arth.2013.07.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2013] [Revised: 07/22/2013] [Accepted: 07/24/2013] [Indexed: 02/01/2023] Open
Abstract
We retrospectively studied 32 consecutive patients (32 hips) who underwent THA with a Durom large-head, MOM articulation between January 2008 and December 2010. Of the patients who underwent THA using a Trilogy metal on polyethylene prosthesis during the same period, 32 were chosen to form the Trilogy group. 32 volunteers were chosen to form the control group. At the last follow-up, serum metal ion levels, liver and kidney function and host immunologic immune responses were evaluated. The mean Co and Cr levels in the Durom group were 4.33- and 1.95-fold higher than those in the Trilogy group. CD3+, CD4+ and CD8+ cell levels in the Durom group were significantly decreased. The INF-γ level in the Durom group was significantly higher than that in the Trilogy and control groups.
Collapse
Affiliation(s)
- Zhefeng Chen
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Zhen Wang
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Qing Wang
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Weiding Cui
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Feng Liu
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Weimin Fan
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| |
Collapse
|
49
|
Abstract
Systemic contact dermatitis (SCD) refers to a skin condition where an individual who is cutaneously sensitized to an allergen will subsequently react to that same allergen or a cross-reacting allergen via the systemic route. It occurs to allergens including metals, medications, and foods. There has been recent interest in metal allergy as it relates to the implantation of devices such as orthopedic, dental, cardiac, and gynecologic implants. This review will briefly address all causes of systemic contact dermatitis with a special and expanded focus on metal implant allergy. We present literature on SCD to various metal biomedical devices, patch testing for diagnosis of metal allergy pre and post implantation and treatment.
Collapse
|
50
|
Hesketh J, Ward M, Dowson D, Neville A. The composition of tribofilms produced on metal-on-metal hip bearings. Biomaterials 2014; 35:2113-9. [DOI: 10.1016/j.biomaterials.2013.11.065] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 11/21/2013] [Indexed: 12/12/2022]
|