Karadeli HH, Kuram E. Single Component Polymers, Polymer Blends, and Polymer Composites for Interventional Endovascular Embolization of Intracranial Aneurysms. Macromol Biosci 2024; 24:e2300432. [PMID: 37992206 DOI: 10.1002/mabi.202300432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/03/2023] [Indexed: 11/24/2023]
Abstract
Intracranial aneurysm is the abnormal focal dilation in brain arteries. When untreated, it can enlarge to rupture points and account for subarachnoid hemorrhage cases. Intracranial aneurysms can be treated by blocking the flow of blood to the aneurysm sac with clipping of the aneurysm neck or endovascular embolization with embolics to promote the formation of the thrombus. Coils or an embolic device are inserted endovascularly into the aneurysm via a micro-catheter to fill the aneurysm. Many embolization materials have been developed. An embolization coil made of soft and thin platinum wire called the "Guglielmi detachable coil" (GDC) enables safer treatment for brain aneurysms. However, patients may experience aneurysm recurrence because of incomplete coil filling or compaction over time. Unsatisfactory recanalization rates and incomplete occlusion are the drawbacks of endovascular embolization. So, the fabrication of new medical devices with less invasive surgical techniques is mandatory to enhance the long-term therapeutic performance of existing endovascular procedures. For this aim, the current article reviews polymeric materials including blends and composites employed for embolization of intracranial aneurysms. Polymeric materials used in embolic agents, their advantages and challenges, results of the strategies used to overcome treatment, and results of clinical experiences are summarized and discussed.
Collapse
Affiliation(s)
- Hasan Hüseyin Karadeli
- Department of Neurology, Istanbul Medeniyet University Göztepe Prof. Dr. Süleyman Yalçın City Hospital, Istanbul, 34722, Turkey
| | - Emel Kuram
- Department of Mechanical Engineering, Gebze Technical University, Kocaeli, 41400, Turkey
| |
Collapse
|
2
|
Donehoo DA, Collier CA, VandenHeuvel SN, Roy S, Solberg SC, Raghavan SA. Degrees of macrophage-facilitated healing in aneurysm occlusion devices. J Biomed Mater Res B Appl Biomater 2024; 112:e35385. [PMID: 38345190 DOI: 10.1002/jbm.b.35385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 12/05/2023] [Accepted: 01/27/2024] [Indexed: 02/15/2024]
Abstract
Insufficient healing of aneurysms following treatment with vascular occlusion devices put patients at severe risk of fatal rupture. Therefore, promoting healing and not just occlusion is vital to enhance aneurysm healing. Following occlusion device implantation, healing is primarily orchestrated by macrophage immune cells, ending with fibroblasts depositing collagen to stabilize the aneurysm neck and dome, preventing rupture. Several modified occlusion devices are available currently on-market. Previous in vivo work demonstrated that modifications of occlusion devices with a shape memory polymer foam had enhanced aneurysm healing outcomes. To better understand cellular response to occlusion devices and improve aneurysm occlusion device design variables, we developed an in vitro assay to isolate prominent interactions between devices and key healing players: macrophages and fibroblasts. We used THP-1 monocyte derived macrophages and human dermal fibroblasts in our cell culture models. Macrophages were allowed device contact with on-market competitor aneurysm occlusion devices for up to 96 h, to allow for any spontaneous device-driven macrophage activation. Macrophage secreted factors were captured in the culture media, in response to device-specific activation. Fibroblasts were then exposed to device-conditioned macrophage media (with secreted factors alone), to determine if there were any device-induced changes in collagen secretion. Our in vitro studies were designed to test the direct effect of devices on macrophage activation, and the indirect effect of devices on collagen secretion by fibroblasts to promote aneurysm healing and stabilization. Over 96 h, macrophages displayed significant migration toward and interaction with all tested devices. As compared to other devices, shape memory polymer foams (SMM, Shape Memory Medical) induced significant changes in gene expression indicating a shift toward an anti-inflammatory pro-healing M2-like phenotype. Similarly, macrophages in contact with SMM devices secreted more vascular endothelial growth factor (VEGF) compared with other devices. Macrophage conditioned media from SMM-contacted macrophages actively promoted fibroblast secretion of collagen, comparable to amounts observed with exogenous stimulation via VEGF supplementation. Our data indicate that SMM devices may promote good aneurysm healing outcomes, because collagen production is an essential step to ultimately stabilize an aneurysm.
Collapse
Affiliation(s)
- Del A Donehoo
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Claudia A Collier
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | | | - Sanjana Roy
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Spencer C Solberg
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Shreya A Raghavan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| |
Collapse
|
3
|
Echeverría D, Rivera R, Giacaman P, Sordo JG, Einersen M, Badilla L. A novel self-expanding shape memory polymer coil for intracranial aneurysm embolization: 1 year follow-up in Chile. J Neurointerv Surg 2023; 15:781-786. [PMID: 35831177 PMCID: PMC10359521 DOI: 10.1136/jnis-2022-018996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Accepted: 06/21/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND Aneurysm recurrence remains a challenge when coiling cerebral aneurysms. Development of next generation coils has focused on accelerating thrombus maturation and increasing coil packing density. Ultra low density shape memory polymer is a novel embolic material designed for this purpose. The polymer is crimped over a platinum-tungsten coil for catheter delivery and self-expands to a predefined volume on contact with blood. METHODS This prospective study in humans evaluated aneurysms 5-16 mm (inclusive) in diameter that were indicated for endovascular coil embolization. At least 70% coil volume was required to be shape memory polymer coils. Patients were followed-up according to standard of care for 12 months. RESULTS Nine patients (89% women, mean age 55.8±11.7 years) were treated with shape memory polymer coils and completed 12 months of follow-up. Aneurysms were all unruptured and were in the ophthalmic segment of the internal carotid artery (n=7), posterior communicating artery, and anterior cerebral artery A1-A2 segment. Aneurysms were a mean of 7.8±2.9 mm in diameter (range 5.2-14.9 mm). The mean packing density based on unexpanded polymer was 17±6%. Packing density based on expanded polymer was 43±13%. At 12 months, no recurrence had occurred, and a Raymond-Roy occlusion classification of 1 (n=5) or 2 (n=4) was observed. No serious adverse events related to the study device occurred over the 12 months after the procedure. CONCLUSIONS Shape memory polymer coils were safe and effective in treating intracranial aneurysms over 12 months in this first study in human subjects.
Collapse
Affiliation(s)
- Daniel Echeverría
- Neuroradiology, Instituto de Neurocirugía Dr Alfonso Asenjo, Santiago, Chile
- Department of Radiology, Universidad de Valparaíso, Valparaíso, Chile
| | - Rodrigo Rivera
- Neuroradiology, Instituto de Neurocirugía Dr Alfonso Asenjo, Santiago, Chile
- Department of Radiology, Universidad de Valparaíso, Valparaíso, Chile
| | - Pablo Giacaman
- Neurovascular Unit, Imaging Service, Hospital Clínico Regional Guillermo Grant Benavente, Concepción, Chile
| | - Juan Gabriel Sordo
- Neuroradiology, Instituto de Neurocirugía Dr Alfonso Asenjo, Santiago, Chile
- Department of Radiology, Universidad de Valparaíso, Valparaíso, Chile
| | - Martín Einersen
- Neurovascular Unit, Imaging Service, Hospital Clínico Regional Guillermo Grant Benavente, Concepción, Chile
- Faculty of Medicine, Department of Specialties (Imaging), Universidad de Concepción, Concepción, Chile
| | - Lautaro Badilla
- Neuroradiology, Instituto de Neurocirugía Dr Alfonso Asenjo, Santiago, Chile
- Department of Radiology, Universidad de Valparaíso, Valparaíso, Chile
| |
Collapse
|
4
|
Vakil AU, Petryk NM, Du C, Howes B, Stinfort D, Serinelli S, Gitto L, Ramezani M, Beaman HT, Monroe MBB. In vitro and in vivo degradation correlations for polyurethane foams with tunable degradation rates. J Biomed Mater Res A 2023; 111:580-595. [PMID: 36752708 DOI: 10.1002/jbm.a.37504] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/19/2022] [Accepted: 01/13/2023] [Indexed: 02/09/2023]
Abstract
Polyurethane foams present a tunable biomaterial platform with potential for use in a range of regenerative medicine applications. Achieving a balance between scaffold degradation rates and tissue ingrowth is vital for successful wound healing, and significant in vivo testing is required to understand these processes. Vigorous in vitro testing can minimize the number of animals that are required to gather reliable data; however, it is difficult to accurately select in vitro degradation conditions that can effectively mimic in vivo results. To that end, we performed a comprehensive in vitro assessment of the degradation of porous shape memory polyurethane foams with tunable degradation rates using varying concentrations of hydrogen peroxide to identify the medium that closely mimics measured in vivo degradation rates. Material degradation was studied over 12 weeks in vitro in 1%, 2%, or 3% hydrogen peroxide and in vivo in subcutaneous pockets in Sprague Dawley rats. We found that the in vitro degradation conditions that best predicted in vivo degradation rates varied based on the number of mechanisms by which the polymer degraded and the polymer hydrophilicity. Namely, more hydrophilic materials that degrade by both hydrolysis and oxidation require lower concentrations of hydrogen peroxide (1%) to mimic in vivo rates, while more hydrophobic scaffolds that degrade by oxidation alone require higher concentrations of hydrogen peroxide (3%) to model in vivo degradation. This information can be used to rationally select in vitro degradation conditions that accurately identify in vivo degradation rates prior to characterization in an animal model.
Collapse
Affiliation(s)
- Anand Utpal Vakil
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Natalie Marie Petryk
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Changling Du
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Bryanna Howes
- Department of Chemistry, Le Moyne College, Syracuse, New York, USA
| | | | | | - Lorenzo Gitto
- SUNY Upstate Medical University, Syracuse, New York, USA
| | - Maryam Ramezani
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Henry T Beaman
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Mary Beth Browning Monroe
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| |
Collapse
|
5
|
Massmann A, Fries P, Shayesteh-Kheslat R, Buecker A, Berg P, Frenzel F. Feasibility of aortic aneurysm sac embolization using a novel shape memory polymer embolic device. Eur Radiol Exp 2023; 7:12. [PMID: 37009937 PMCID: PMC10068687 DOI: 10.1186/s41747-023-00328-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 01/30/2023] [Indexed: 04/04/2023] Open
Abstract
BACKGROUND We investigated the feasibility of aneurysm sac embolization using a novel self-expanding porous shape memory polymer (SMP) device during endovascular aortic abdominal or thoracic aneurysm repair (EVAR). METHODS Retrospective analysis of consecutive patients treated at 2 centers in Germany. Patients were treated from January 2019 to July 2021 with follow-up at 7 days and 3, 6, and 12 months. Aneurysm sacs were implanted with SMP devices immediately following endograft placement during the same procedure. Primary endpoint was technically successful SMP-device deployment into the aneurysm sac outside the endograft. Secondary endpoints were changes in aneurysm volume and associated complications (e.g., endoleaks). RESULTS We included 18 patients (16 males), aged 72 ± 9 years, achieving 100% technical success. Mean preprocedure aortic aneurysm sac volume was 195 ± 117 mL with a perfused aneurysm volume of 97 ± 60 mL. A mean of 24 ± 12 SMP devices per patient were used (range 5-45, corresponding to 6.25-56.25 mL expanded embolic material volume). All evaluable patients exhibited sac regression except 2 patients yet to reach 3-month follow-up. At mean 11 ± 7 months (range 3-24), change in aneurysm volume from baseline was -30 ± 21 mL (p < 0.001). In 8 patients, aneurysm regression was observed despite type 2 endoleaks in 6 and type 1A endoleaks in 2, none of them requiring further intervention to date. No morbidity or mortality related to this treatment occurred. CONCLUSIONS SMP devices for aortic aneurysm sac embolization during endovascular repair appear feasible and safe in this small case series. Prospective studies are needed. KEY POINTS • Shape memory polymer is a novel, self-expanding, porous, and radiolucent embolic device material. • Aortic aneurysm sacs were treated with polymer devices immediately following endograft placement. • Aortic aneurysm sac regression was observed in all patients with over 3-month follow-up. • Aortic aneurysm sac regression was observed even in the presence of endoleaks.
Collapse
Affiliation(s)
- Alexander Massmann
- Radiology and Nuclear Medicine, Bosch Health Campus, Robert-Bosch-Krankenhaus, Auerbachstraße 110, 70376, Stuttgart, Germany.
| | - Peter Fries
- Diagnostic and Interventional Radiology, Saarland University Medical Center, Homburg/Saar, Germany
| | - Roushanak Shayesteh-Kheslat
- Clinic for General, Visceral, Vascular and Pediatric Surgery, Saarland University Medical Center, Homburg/Saar, Germany
| | - Arno Buecker
- Diagnostic and Interventional Radiology, Saarland University Medical Center, Homburg/Saar, Germany
| | - Patrick Berg
- Clinic for Vascular Surgery, Katholisches Karl-Leisner-Klinikum, Kevelaer, Germany
| | - Felix Frenzel
- Diagnostic and Interventional Radiology, Saarland University Medical Center, Homburg/Saar, Germany
| |
Collapse
|
6
|
Ramaraju H, McAtee AM, Akman RE, Verga AS, Bocks ML, Hollister SJ. Sterilization effects on poly(glycerol dodecanedioate): A biodegradable shape memory elastomer for biomedical applications. J Biomed Mater Res B Appl Biomater 2023; 111:958-970. [PMID: 36479954 DOI: 10.1002/jbm.b.35205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 10/31/2022] [Accepted: 11/15/2022] [Indexed: 12/13/2022]
Abstract
Biodegradable shape memory polymers provide unique regenerative medicine approaches in minimally invasive surgeries. Once heated, thermally responsive shape memory polymer devices can be compressed, programmed to fit within a small profile, delivered in the cold programmed state, and expanded when heated to body temperature. We have previously developed a biodegradable shape memory elastomer (SME), poly(glycerol dodecanedioate) (PGD), with transition temperatures near 37°C exhibiting nonlinear elastic properties like numerous soft tissues. Using SMEs in the clinic requires disinfection and sterilization methods that conserve physiochemical, thermomechanical, and shape recovery properties. We evaluated disinfection protocols using 70% ethanol and UV254 nm for research applications and ethylene oxide (EtO) gas sterilization for clinical applications. Samples disinfected with ethanol for 0.5 and 1 min showed no changes in physiochemical material properties, but after 15 min showed slower recovery rates than controls (p < .05). EtO sterilization at 54.4°C decreased transition temperatures and shape recovery rate compared to EtO sterilization at 37.8°C (p < .01) and controls (p < .05). Aging samples for 9 months in a vacuum desiccator significantly reduced shape recovery, and the recovery rate in EtO sterilized samples compared to controls (p < .001). Cytotoxicity testing (ISO-10993.5C:2012) revealed media extractions from EtO sterilized samples, sterilized at 37.8°C, and high-density polyethylene negative control samples exhibit lower cytotoxicity (IC50) than Ethanol 1 min, UV 2 h, and EtO 54.4°C. Cell viability of NIH3T3 fibroblasts on sterilized surfaces was equivalent on EtO 37.7°C, EtO 54.4°C and Ethanol sterilized substrates. Finally, chromogenic bacterial endotoxin testing showed endotoxin levels were below the FDA prescribed levels for devices contacting blood and lymphatic tissues for ethanol 1 min, UV 120 min, EtO 37.7°C, EtO 54.4°C. These findings outline various disinfection and sterilization processes for research and pre-clinical application and provide a pathway for developing custom sterilization cycles for the translation of biomedical devices utilizing PGD shape memory polymers.
Collapse
Affiliation(s)
- Harsha Ramaraju
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Annabel M McAtee
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Ryan E Akman
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Adam S Verga
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Martin L Bocks
- UH Rainbow Babies & Children's Hospital, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
| | - Scott J Hollister
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
7
|
Ramaraju H, Massarella D, Wong C, Verga AS, Kish EC, Bocks ML, Hollister SJ. Percutaneous delivery and degradation of a shape memory elastomer poly(glycerol dodecanedioate) in porcine pulmonary arteries. Biomaterials 2023; 293:121950. [PMID: 36580715 DOI: 10.1016/j.biomaterials.2022.121950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 11/23/2022] [Accepted: 12/05/2022] [Indexed: 12/13/2022]
Abstract
Shape memory biodegradable elastomers are an emergent class of biomaterials well-suited for percutaneous cardiovascular repair requiring nonlinear elastic materials with facile handling. We have previously developed a chemically crosslinked shape memory elastomer, poly (glycerol dodecanedioate) (PGD), exhibiting tunable transition temperatures around body temperature (34-38 °C), exhibiting nonlinear elastic properties approximating cardiac tissues, and favorable degradation rates in vitro. Degree of tissue coverage, degradation and consequent changes in polymer thermomechanical properties, and inflammatory response in preclinical animal models are unknown material attributes required for translating this material into cardiovascular devices. This study investigates changes in the polymer structure, tissue coverage, endothelialization, and inflammation of percutaneously implanted PGD patches (20 mm × 9 mm x 0.5 mm) into the branch pulmonary arteries of Yorkshire pigs for three months. After three months in vivo, 5/8 samples exhibited (100%) tissue coverage, 2/8 samples exhibited 85-95% tissue coverage, and 1/8 samples exhibited limited (<20%) tissue coverage with mild-moderate inflammation. PGD explants showed a (60-70%) volume loss and (25-30%) mass loss, and a reduction in polymer crosslinks. Lumenal and mural surfaces and the cross-section of the explant demonstrated evidence of degradation. This study validates PGD as an appropriate cardiovascular engineering material due to its propensity for rapid tissue coverage and uneventful inflammatory response in a preclinical animal model, establishing a precedent for consideration in cardiovascular repair applications.
Collapse
Affiliation(s)
- Harsha Ramaraju
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology Atlanta, GA 30312, USA.
| | - Danielle Massarella
- UH Rainbow Babies & Children's Hospital, Department of Pediatrics, Division of Pediatric, Cardiology, Case Western Reserve University School of Medicine, Cleveland, OH 44106, USA
| | - Courtney Wong
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology Atlanta, GA 30312, USA
| | - Adam S Verga
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology Atlanta, GA 30312, USA
| | - Emily C Kish
- UH Rainbow Babies & Children's Hospital, Department of Pediatrics, Division of Pediatric, Cardiology, Case Western Reserve University School of Medicine, Cleveland, OH 44106, USA
| | - Martin L Bocks
- UH Rainbow Babies & Children's Hospital, Department of Pediatrics, Division of Pediatric, Cardiology, Case Western Reserve University School of Medicine, Cleveland, OH 44106, USA
| | - Scott J Hollister
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology Atlanta, GA 30312, USA.
| |
Collapse
|
8
|
Ghosh A, Xiao N, Gordon AC, Funaki B, Lewandowski RJ. Embolic Agents: Vascular Plugs. Semin Intervent Radiol 2022; 39:526-532. [PMID: 36561938 PMCID: PMC9767762 DOI: 10.1055/s-0042-1758112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Abheek Ghosh
- Division of Vascular and Interventional Radiology, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland
| | - Nicholas Xiao
- Division of Interventional Radiology, Department of Radiology, Northwestern University, Chicago, Illinois
| | - Andrew C. Gordon
- Division of Interventional Radiology, Department of Radiology, Northwestern University, Chicago, Illinois
| | - Brian Funaki
- Division of Vascular and Interventional Radiology, University of Chicago Medicine, Chicago, Illinois
| | - Robert J. Lewandowski
- Division of Interventional Radiology, Department of Radiology, Northwestern University, Chicago, Illinois
| |
Collapse
|
9
|
Graul LM, Horn SJ, Nash LD, Cheung TB, Clubb FJ, Maitland DJ. Image-Based Evaluation of In Vivo Degradation for Shape-Memory Polymer Polyurethane Foam. Polymers (Basel) 2022; 14:4122. [PMID: 36236069 PMCID: PMC9571375 DOI: 10.3390/polym14194122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/09/2022] [Accepted: 09/12/2022] [Indexed: 11/06/2022] Open
Abstract
Shape-memory polymer (SMP) polyurethane foams have been applied as embolic devices and implanted in multiple animal models. These materials are oxidatively degradable and it is critical to quantify and characterize the degradation for biocompatibility assessments. An image-based method using high-resolution and magnification scans of histology sections was used to estimate the mass loss of the peripheral and neurovascular embolization devices (PED, NED). Detailed analysis of foam microarchitecture (i.e., struts and membranes) was used to estimate total relative mass loss over time. PED foams implanted in porcine arteries showed a degradation rate of ~0.11% per day as evaluated at 30-, 60-, and 90-day explant timepoints. NED foams implanted in rabbit carotid elastase aneurysms showed a markedly faster rate of degradation at ~1.01% per day, with a clear difference in overall degradation between 30- and 90-day explants. Overall, membranes degraded faster than the struts. NEDs use more hydrophobic foam with a smaller pore size (~150-400 μm) compared to PED foams (~800-1200 μm). Previous in vitro studies indicated differences in the degradation of the two polymer systems, but not to the magnitude seen in vivo. Implant location, animal species, and local tissue health are among the hypothesized reasons for different degradation rates.
Collapse
Affiliation(s)
- Lance M. Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Staci J. Horn
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX 77843, USA
| | | | - Thomas B. Cheung
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Fred J. Clubb
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX 77843, USA
| | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Shape Memory Medical Inc., Santa Clara, CA 95054, USA
| |
Collapse
|
10
|
Liu W, Li S, Wang B, Peng P, Gao C. Physiologically Responsive Polyurethanes for Tissue Repair and Regeneration. ADVANCED NANOBIOMED RESEARCH 2022. [DOI: 10.1002/anbr.202200061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Affiliation(s)
- Wenxing Liu
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization Department of Polymer Science and Engineering Zhejiang University Hangzhou 310027 China
| | - Shifen Li
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization Department of Polymer Science and Engineering Zhejiang University Hangzhou 310027 China
| | - Beiduo Wang
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization Department of Polymer Science and Engineering Zhejiang University Hangzhou 310027 China
| | - Pai Peng
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization Department of Polymer Science and Engineering Zhejiang University Hangzhou 310027 China
| | - Changyou Gao
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization Department of Polymer Science and Engineering Zhejiang University Hangzhou 310027 China
| |
Collapse
|
11
|
Pineda-Castillo SA, Stiles AM, Bohnstedt BN, Lee H, Liu Y, Lee CH. Shape Memory Polymer-Based Endovascular Devices: Design Criteria and Future Perspective. Polymers (Basel) 2022; 14:polym14132526. [PMID: 35808573 PMCID: PMC9269599 DOI: 10.3390/polym14132526] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/13/2022] [Accepted: 06/17/2022] [Indexed: 12/12/2022] Open
Abstract
Devices for the endovascular embolization of intracranial aneurysms (ICAs) face limitations related to suboptimal rates of lasting complete occlusion. Incomplete occlusion frequently leads to residual flow within the aneurysm sac, which subsequently causes aneurysm recurrence needing surgical re-operation. An emerging method for improving the rates of complete occlusion both immediately after implant and in the longer run can be the fabrication of patient-specific materials for ICA embolization. Shape memory polymers (SMPs) are materials with great potential for this application, owing to their versatile and tunable shape memory properties that can be tailored to a patient’s aneurysm geometry and flow condition. In this review, we first present the state-of-the-art endovascular devices and their limitations in providing long-term complete occlusion. Then, we present methods for the fabrication of SMPs, the most prominent actuation methods for their shape recovery, and the potential of SMPs as endovascular devices for ICA embolization. Although SMPs are a promising alternative for the patient-specific treatment of ICAs, there are still limitations that need to be addressed for their application as an effective coil-free endovascular therapy.
Collapse
Affiliation(s)
- Sergio A. Pineda-Castillo
- Biomechanics and Biomaterials Design Laboratory (BBDL), The University of Oklahoma, Norman, OK 73019, USA; (S.A.P.-C.); (A.M.S.)
- Stephenson School of Biomedical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Aryn M. Stiles
- Biomechanics and Biomaterials Design Laboratory (BBDL), The University of Oklahoma, Norman, OK 73019, USA; (S.A.P.-C.); (A.M.S.)
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA;
| | - Bradley N. Bohnstedt
- Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, IN 46202, USA;
| | - Hyowon Lee
- Laboratory of Implantable Microsystems Research (LIMR), Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA;
| | - Yingtao Liu
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA;
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory (BBDL), The University of Oklahoma, Norman, OK 73019, USA; (S.A.P.-C.); (A.M.S.)
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA;
- Correspondence:
| |
Collapse
|
12
|
Graul LM, Liu S, Maitland DJ. Theoretical error of sectional method for estimation of shape memory polyurethane foam mass loss. J Colloid Interface Sci 2022; 625:237-247. [PMID: 35716618 DOI: 10.1016/j.jcis.2022.06.045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 06/03/2022] [Accepted: 06/09/2022] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Measuring in vivo degradation for polymeric scaffolds is critical for analysis of biocompatibility. Traditionally, histology has been used to estimate mass loss in scaffolds, allowing for simultaneous evaluation of mass loss and the biologic response to the implant. Oxidatively degradable shape memory polyurethane (SMP) foams have been implemented in two vascular occlusion devices: peripheral embolization device (PED) and neurovascular embolization device (NED). This work explores the errors introduced when using histological sections to evaluate mass loss. METHODS Models of the SMP foams were created to mimic the device geometry and the tetrakaidekahedral structure of the foam pore. These models were degraded in Blender for a wide range of possible degradation amounts and the mass loss was estimated using m sections. RESULTS As the number of sections (m) used to estimate mass loss for a volume increased the sampling error decreased and beyond m = 5, the decrease in error was insignificant. NED population and sampling errors were higher than for PED scenarios. When m ≥ 5, the averaged sampling error was below 1.5% for NED and 1% for PED scenarios. DISCUSSION/CONCLUSION This study establishes a baseline sampling error for estimating randomly degraded porous scaffolds using a sectional method. Device geometry and the stage of mass loss influence the sampling error. Future studies will use non-random degradation to further investigate in vivo mass loss scenarios.
Collapse
Affiliation(s)
- Lance M Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
| | - Shuling Liu
- Department of Statistics, Texas A&M University, College Station, TX, United States
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States.
| |
Collapse
|
13
|
Hasan SM, Touchet T, Jayadeep A, Maitland DJ. Controlling Morphology and Physio-Chemical Properties of Stimulus-Responsive Polyurethane Foams by Altering Chemical Blowing Agent Content. Polymers (Basel) 2022; 14:polym14112288. [PMID: 35683960 PMCID: PMC9183079 DOI: 10.3390/polym14112288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 05/25/2022] [Accepted: 06/01/2022] [Indexed: 12/16/2022] Open
Abstract
Amorphous shape memory polymer foams are currently used as components in vascular occlusion medical devices such as the IMPEDE and IMPEDE-FX Embolization Plugs. Body temperature and moisture-driven actuation of the polymeric foam is necessary for vessel occlusion and the rate of expansion is a function of physio-chemical material properties. In this study, concentrations of the chemical blowing agent for the foam were altered and the resulting effects on morphology, thermal and chemical properties, and actuation rates were studied. Lower concentration of chemical blowing agent yielded foams with thick foam struts due to less bubble formation during the foaming process. Foams with thicker struts also had high tensile modulus and lower strain at break values compared to the foams made with higher blowing agent concentration. Additionally, less blowing agent resulted in foams with a lower glass transition temperature due to less urea formation during the foaming reaction. This exploratory study provides an approach to control thermo-mechanical foam properties and morphology by tuning concentrations of a foaming additive. This work aims to broaden the applications of shape memory polymer foams for medical use.
Collapse
Affiliation(s)
- Sayyeda Marziya Hasan
- Shape Memory Medical Inc., Santa Clara, CA 95054, USA
- Correspondence: ; Tel.: +281-745-8366
| | - Tyler Touchet
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (T.T.); (D.J.M.)
| | - Aishwarya Jayadeep
- Materials Science and Engineering, University of California, Berkeley, CA 94720, USA;
| | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (T.T.); (D.J.M.)
| |
Collapse
|
14
|
Chau SM, Herting SM, Noltensmeyer DA, Ahmed H, Maitland DJ, Raghavan S. Macrophage activation in response to shape memory polymer foam-coated aneurysm occlusion devices. J Biomed Mater Res B Appl Biomater 2022; 110:1535-1544. [PMID: 35090200 DOI: 10.1002/jbm.b.35015] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 12/17/2021] [Accepted: 01/19/2022] [Indexed: 01/30/2023]
Abstract
Brain aneurysms can be treated with embolic coils using minimally invasive approaches. It is advantageous to modulate the biologic response of platinum embolic coils. Our previous studies demonstrated that shape memory polymer (SMP) foam coated embolization coils (FCC) devices demonstrate enhanced healing responses in animal models compared with standard bare platinum coil (BPC) devices. Macrophages are the most prevalent immune cell type that coordinate the greater immune response to implanted materials. Hence, we hypothesized that the highly porous SMP foam coatings on embolic coils activate a pro-regenerative healing phenotype. To test this hypothesis, we analyzed the number and type of infiltrating macrophages in FCC or BPC devices implanted in a rabbit elastase aneurysm model. FCC devices elicited a great number of infiltration macrophages, skewed significantly to a pro-regenerative M2-like phenotype 90 days following implantation. We devised an in vitro assay, where monocyte-derived macrophages were placed in close association with FCC or BPC devices for 6-72 h. Macrophages encountering SMP FCC-devices demonstrated highly mixed activation phenotypes at 6 h, heavily skewing toward an M2-like phenotype by 72 h, compared with macrophages encountering BPC devices. Macrophage activation was evaluated using gene expression analysis, and secreted cytokine evaluation. Together, our results demonstrate that FCC devices promoted a pro-regenerative macrophage activation phenotype, compared with BPC devices. Our in vitro findings corroborate with in vivo observations that SMP-based modification of embolic coils can promote better healing of the aneurysm site, by sustaining a pro-healing macrophage phenotype.
Collapse
Affiliation(s)
- Sarah M Chau
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
- TAMU Master of Biotechnology Program, Texas A&M University, College Station, Texas, USA
| | - Scott M Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Dillon A Noltensmeyer
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Hamzah Ahmed
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Shreya Raghavan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, Texas, USA
| |
Collapse
|
15
|
Pandey PK, Das MK. Effect of foam insertion in aneurysm sac on flow structures in parent lumen: relating vortex structures with disturbed shear. Phys Eng Sci Med 2021; 44:1231-1248. [PMID: 34581959 DOI: 10.1007/s13246-021-01058-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 09/05/2021] [Indexed: 11/26/2022]
Abstract
Numerous studies suggest that disturbed shear, causing endothelium dysfunction, can be related to neighboring vortex structures. With this motivation, this study presents a methodology to characterize the vortex structures. Precisely, we use mapping and characterization of vortex structures' changes to relate it with the hemodynamic indicators of disturbed shear. Topological features of vortex core lines (VCLs) are used to quantify the changes in vortex structures. We use the Sujudi-Haimes algorithm to extract the VCLs from the flow simulation results. The idea of relating vortex structures with disturbed shear is demonstrated for cerebral arteries with aneurysms virtually treated by inserting foam in the sac. To get physiologically realistic flow fields, we simulate blood flow in two patient-specific geometries before and after foam insertion, with realistic velocity waveform imposed at the inlet, using the Carreau-Yasuda model to mimic the shear-thinning behavior. With homogenous porous medium assumption, flow through the foam is modeled using the Forchheimer-Brinkman extended Darcy model. Results show that foam insertion increases the number of VCLs in the parent lumen. The average length of VCL increases by 168.9% and 55.6% in both geometries. For both geometries under consideration, results demonstrate that the region with increased disturbed shear lies in the same arterial segment exhibiting an increase in the number of oblique VCLs. Based on the findings, we conjecture that an increase in oblique VCLs is related to increased disturbed shear at the neighboring portion of the arterial wall.
Collapse
Affiliation(s)
- Pawan Kumar Pandey
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, 208016, Uttar Pradesh, India
| | - Malay Kumar Das
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, 208016, Uttar Pradesh, India.
| |
Collapse
|
16
|
Kim S, Nowicki KW, Gross BA, Wagner WR. Injectable hydrogels for vascular embolization and cell delivery: The potential for advances in cerebral aneurysm treatment. Biomaterials 2021; 277:121109. [PMID: 34530233 DOI: 10.1016/j.biomaterials.2021.121109] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 08/23/2021] [Accepted: 08/27/2021] [Indexed: 12/11/2022]
Abstract
Cerebral aneurysms are vascular lesions caused by the biomechanical failure of the vessel wall due to hemodynamic stress and inflammation. Aneurysmal rupture results in subarachnoid hemorrhage often leading to death or disability. Current treatment options include open surgery and minimally invasive endovascular options aimed at secluding the aneurysm from the circulation. Cerebral aneurysm embolization with appropriate materials is a therapeutic approach to prevent rupture and the resultant clinical sequelae. Metallic platinum coils are a typical, practical option to embolize cerebral aneurysms. However, the development of an alternative treatment modality is of interest because of poor occlusion permanence, coil migration, and coil compaction. Moreover, minimizing the implanted foreign materials during therapy is of importance not just to patients, but also to clinicians in the event an open surgical approach has to be pursued in the future. Polymeric injectable hydrogels have been investigated for transcatheter embolization and cell therapy with the potential for permanent aneurysm repair. This review focuses on how the combination of injectable embolic biomaterials and cell therapy may achieve minimally invasive remodeling of a degenerated cerebral artery with promise for superior outcomes in treatment of this devastating disease.
Collapse
Affiliation(s)
- Seungil Kim
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Surgery, University of Pittsburgh, Pittsburgh, PA, USA
| | - Kamil W Nowicki
- Department of Neurosurgery, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Bradley A Gross
- Department of Neurosurgery, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - William R Wagner
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Surgery, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
17
|
Pandey PK, Paul C, Das MK, Muralidhar K. Assessment and visualization of hemodynamic loading in aneurysm sac and neck: Effect of foam insertion. Proc Inst Mech Eng H 2021; 235:927-939. [PMID: 33971763 DOI: 10.1177/09544119211015569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Shape memory polymer (SMP) foam is often proposed as the future alternative of coils in aneurysm treatment devices. Present work numerically investigates the unsteady, three-dimensional simulation of blood flow in a cerebral aneurysm filled with SMP foam. Simulations are conducted on patient-specific geometries with realistic blood velocity waveform imposed at the inlet while SMP foam is treated as a porous medium. The present study introduces a "loading risk map" that helps to visualize the hemodynamic effect of foam insertion on the aneurysm sac and neck. The loading risk maps suggest that while the SMP foam subdues the flow and wall shear pulsations in the aneurysm sac, the pressure distribution is minimally affected. The maps suggest that while the downstream lip is the most risk-prone site for both geometries, downstream vascular anatomy significantly influences foam efficiency in reducing pressure and wall shear stress loading.
Collapse
Affiliation(s)
- Pawan Kumar Pandey
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, UP, India
| | - Chandan Paul
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, UP, India
| | - Malay K Das
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, UP, India
| | | |
Collapse
|
18
|
Wendels S, Avérous L. Biobased polyurethanes for biomedical applications. Bioact Mater 2021; 6:1083-1106. [PMID: 33102948 PMCID: PMC7569269 DOI: 10.1016/j.bioactmat.2020.10.002] [Citation(s) in RCA: 113] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 10/01/2020] [Accepted: 10/01/2020] [Indexed: 12/15/2022] Open
Abstract
Polyurethanes (PUs) are a major family of polymers displaying a wide spectrum of physico-chemical, mechanical and structural properties for a large range of fields. They have shown suitable for biomedical applications and are used in this domain since decades. The current variety of biomass available has extended the diversity of starting materials for the elaboration of new biobased macromolecular architectures, allowing the development of biobased PUs with advanced properties such as controlled biotic and abiotic degradation. In this frame, new tunable biomedical devices have been successfully designed. PU structures with precise tissue biomimicking can be obtained and are adequate for adhesion, proliferation and differentiation of many cell's types. Moreover, new smart shape-memory PUs with adjustable shape-recovery properties have demonstrated promising results for biomedical applications such as wound healing. The fossil-based starting materials substitution for biomedical implants is slowly improving, nonetheless better renewable contents need to be achieved for most PUs to obtain biobased certifications. After a presentation of some PU generalities and an understanding of a biomaterial structure-biocompatibility relationship, recent developments of biobased PUs for non-implantable devices as well as short- and long-term implants are described in detail in this review and compared to more conventional PU structures.
Collapse
Affiliation(s)
- Sophie Wendels
- BioTeam/ICPEES-ECPM, UMR CNRS 7515, Université de Strasbourg, 25 Rue Becquerel, 67087, Strasbourg Cedex 2, France
| | - Luc Avérous
- BioTeam/ICPEES-ECPM, UMR CNRS 7515, Université de Strasbourg, 25 Rue Becquerel, 67087, Strasbourg Cedex 2, France
| |
Collapse
|
19
|
Herting SM, Monroe MBB, Weems AC, Briggs ST, Fletcher GK, Blair SE, Hatch CJ, Maitland DJ. In vitro cytocompatibility testing of oxidative degradation products. J BIOACT COMPAT POL 2021. [DOI: 10.1177/08839115211003115] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Implantable medical devices must undergo thorough evaluation to ensure safety and efficacy before use in humans. If a device is designed to degrade, it is critical to understand the rate of degradation and the degradation products that will be released. Oxidative degradation is typically modeled in vitro by immersing materials or devices in hydrogen peroxide, which can limit further analysis of degradation products in many cases. Here we demonstrate a novel approach for testing the cytocompatibility of degradation products for oxidatively-degradable biomaterials where the materials are exposed to hydrogen peroxide, and then catalase enzyme is used to convert the hydrogen peroxide to water and oxygen so that the resulting aqueous solution can be added to cell culture media. To validate our results, expected degradation products are also synthesized then added to cell culture media. We used these methods to evaluate the cytocompatibility of degradation products from an oxidatively-degradable shape memory polyurethane designed in our lab and found that the degradation of these polymers is unlikely to cause a cytotoxic response in vivo based on the guidance provided by ISO 10993-5. These methods may also be applicable to other biocompatibility tests such as tests for mutagenicity or systemic toxicity, and evaluations of cell proliferation, migration, or gene and protein expression.
Collapse
Affiliation(s)
- Scott M Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Mary Beth B Monroe
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Andrew C Weems
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Sam T Briggs
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Grace K Fletcher
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Samuel E Blair
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Christopher J Hatch
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| |
Collapse
|
20
|
Poupart O, Conti R, Schmocker A, Pancaldi L, Moser C, Nuss KM, Sakar MS, Dobrocky T, Grützmacher H, Mosimann PJ, Pioletti DP. Pulsatile Flow-Induced Fatigue-Resistant Photopolymerizable Hydrogels for the Treatment of Intracranial Aneurysms. Front Bioeng Biotechnol 2021; 8:619858. [PMID: 33553124 PMCID: PMC7855579 DOI: 10.3389/fbioe.2020.619858] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 12/22/2020] [Indexed: 11/13/2022] Open
Abstract
An alternative intracranial aneurysm embolic agent is emerging in the form of hydrogels due to their ability to be injected in liquid phase and solidify in situ. Hydrogels have the ability to fill an aneurysm sac more completely compared to solid implants such as those used in coil embolization. Recently, the feasibility to implement photopolymerizable poly(ethylene glycol) dimethacrylate (PEGDMA) hydrogels in vitro has been demonstrated for aneurysm application. Nonetheless, the physical and mechanical properties of such hydrogels require further characterization to evaluate their long-term integrity and stability to avoid implant compaction and aneurysm recurrence over time. To that end, molecular weight and polymer content of the hydrogels were tuned to match the elastic modulus and compliance of aneurysmal tissue while minimizing the swelling volume and pressure. The hydrogel precursor was injected and photopolymerized in an in vitro aneurysm model, designed by casting polydimethylsiloxane (PDMS) around 3D printed water-soluble sacrificial molds. The hydrogels were then exposed to a fatigue test under physiological pulsatile flow, inducing a combination of circumferential and shear stresses. The hydrogels withstood 5.5 million cycles and no significant weight loss of the implant was observed nor did the polymerized hydrogel protrude or migrate into the parent artery. Slight surface erosion defects of 2–10 μm in depth were observed after loading compared to 2 μm maximum for non-loaded hydrogels. These results show that our fine-tuned photopolymerized hydrogel is expected to withstand the physiological conditions of an in vivo implant study.
Collapse
Affiliation(s)
- Oriane Poupart
- Laboratory of Biomechanical Orthopedics, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Riccardo Conti
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Zurich, Switzerland
| | - Andreas Schmocker
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Zurich, Switzerland.,Laboratory of Applied Photonics Devices, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.,Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Lucio Pancaldi
- Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Christophe Moser
- Laboratory of Applied Photonics Devices, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Katja M Nuss
- Musculoskeletal Research Unit, Department of Molecular Mechanisms of Disease, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Mahmut S Sakar
- Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tomas Dobrocky
- Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Hansjörg Grützmacher
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Zurich, Switzerland
| | - Pascal J Mosimann
- Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, Bern, Switzerland.,Department of Diagnostic and Interventional Neuroradiology, Alfried Krupp Hospital, Essen, Germany
| | - Dominique P Pioletti
- Laboratory of Biomechanical Orthopedics, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
21
|
Shape Memory Polymer Foams Synthesized Using Glycerol and Hexanetriol for Enhanced Degradation Resistance. Polymers (Basel) 2020; 12:polym12102290. [PMID: 33036235 PMCID: PMC7600845 DOI: 10.3390/polym12102290] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/01/2020] [Accepted: 10/05/2020] [Indexed: 01/21/2023] Open
Abstract
Shape memory polymer foams have been used in a wide range of medical applications, including, but not limited to, vessel occlusion and aneurysm treatment. This unique polymer system has been proven to shape-fill a void, which makes it useful for occlusion applications. While the shape memory polymer foam has superior performance and healing outcomes compared to its leading competitors, some device applications may benefit from longer material degradation times, or degradation-resistant formulations with increased fibrous encapsulation. In this study, biostable shape memory polymer foams were synthesized, and their physical and chemical properties were characterized as an initial evaluation of feasibility for vascular occlusion applications. After characterizing their shape memory behavior in an aqueous environment, degradation of this polymer system was studied in vitro using accelerated oxidative and hydrolytic solutions. Results indicated that the foams did not lose mass under oxidative or hydrolytic conditions, and they maintained high shape recovery in aqueous in vitro models. These degradation-resistant systems have potential for use in vascular occlusion and other wound healing applications that benefit from permanent, space-filling shape memory behavior.
Collapse
|
22
|
Christmas N, Vakil AU, Hatch CJ, Dong S, Fikhman D, Beaman HT, Monroe MBB. Characterization of shape memory polymer foam hemostats in in vitro hemorrhagic wound models. J Biomed Mater Res B Appl Biomater 2020; 109:681-692. [PMID: 32969163 DOI: 10.1002/jbm.b.34732] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/19/2020] [Accepted: 09/15/2020] [Indexed: 11/05/2022]
Abstract
Shape memory polymer foam hemostats are a promising option for future hemorrhage control in battlefield wounds. To enable their use as hemostatic devices, they must be optimized in terms of formulation and architecture, and their safety and efficacy must be characterized in animal models. Relevant in vitro models can be used for device optimization to help mitigate the excess use of animals and reduce costs of clinical translation. In this work, a simplified gunshot wound model and a grade V liver injury model were constructed. The models were used to characterize the effects of shape memory polymer foam hemostat geometry on wall pressures, application/removal times, hemorrhage (fluid loss), and fluid absorption in comparison with clinical controls. It was found that there is no benefit in over-sizing the hemostatic device relative to wound volume and that geometry effects are dependent upon the wound type. These models provide a rapid means for elucidation of promising hemostat geometries and formulations for use in future in vivo testing.
Collapse
Affiliation(s)
- Nakira Christmas
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Anand Utpal Vakil
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Christopher J Hatch
- Department of Biomedical Engineering, California Polytechnic State University, San Luis Obispo, California, USA
| | - Shi Dong
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - David Fikhman
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Henry T Beaman
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Mary Beth B Monroe
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| |
Collapse
|
23
|
Ginn-Hedman A, Jessen SL, Friedemann MC, Nichols RM, Maitland DJ, Clubb FJ. Correlation of light microscopic findings with transmission electron microscopy within a vascular occlusion device. Cardiovasc Pathol 2020; 50:107288. [PMID: 32931920 DOI: 10.1016/j.carpath.2020.107288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 09/08/2020] [Accepted: 09/09/2020] [Indexed: 11/30/2022] Open
Abstract
Host response to an implanted biomaterial is a complex process involving microscopic changes in extracellular matrix (ECM) composition. Reliable pathology analysis is imperative for accurate assessment of the tissue response to an implanted device. Plastic histology is commonly used for histology evaluation of medical devices to assess the device-tissue interface; however, this technique is prone to variable staining that can confound histology interpretation. Appropriately, we propose using transmission electron microscopy (TEM) to confirm histologic ECM findings in order to provide sufficient host-response data. Tissue response to an absorbable shape memory polymer intravascular occlusion device with a nitinol wire backbone was evaluated. Representative plastic-embedded, micro-ground sections from 30-day, 60-day, and 90-day timepoints were analyzed. ECM regions were selected, and ultrathin sections were created for TEM evaluation. Histological changes in ECM composition were compared for light microscopy (LM) and TEM findings; specifically, TEM fibrillary patterns for collagen and fibrin were used to confirm LM results. Throughout this study, LM reveals inconsistent staining in plastic-embedded sections. TEM, on the other hand, provides clear insight into the tissue response by morphologically discerning distinct fibrillary patterns within ECM structures; loose to dense collagen surrounds the implant as fibrin degrades, demonstrating progression of postimplant ECM maturation. Moreover, TEM serves as a definitive method for confirming tissue substrate morphology when LM findings prove ambiguous.
Collapse
Affiliation(s)
- A Ginn-Hedman
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
| | - S L Jessen
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States; Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, United States
| | - M C Friedemann
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, United States
| | - R M Nichols
- Cardiovascular Pathology Laboratory, Texas Heart Institute, Houston, TX, United States
| | - D J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States; Shape Memory Medical Inc., Santa Clara, CA, United States
| | - F J Clubb
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States; Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, United States.
| |
Collapse
|
24
|
Zhang F, Xia Y, Liu Y, Leng J. Nano/microstructures of shape memory polymers: from materials to applications. NANOSCALE HORIZONS 2020; 5:1155-1173. [PMID: 32567643 DOI: 10.1039/d0nh00246a] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Shape memory polymers (SMPs) are macromolecules in which linear chains and crosslinking points play a key role in providing a shape memory effect. As smart polymers, SMPs have the ability to change shape, stiffness, size, and structure when exposed to external stimuli, leading to potential uses for SMPs throughout our daily lives in a diverse range of areas including the aerospace and automotive industries, robotics, biomedical engineering, smart textiles, and tactile devices. SMPs can be fabricated in many forms and sizes from the nanoscale to the macroscale, including nanofibers, nanoparticles, thin films, microfoams, and bulk devices. The introduction of nanostructure into SMPs can result in enhanced mechanical properties, unique structural color, specific surface area, and multiple functions. It is necessary to enhance the current understanding of the various nano/microstructures of SMPs and their fabrication, and to find suitable approaches for constructing SMP-based nano/microstructures for different applications. In this review, we summarize the current state of different SMP nano/microstructures, fabrication techniques, and applications, and give suggestions for their future development.
Collapse
Affiliation(s)
- Fenghua Zhang
- National Key Laboratory of Science and Technology on Advanced Composites in Special Enviroments, Harbin Institute of Technology (HIT), Harbin 150080, P. R. China.
| | | | | | | |
Collapse
|
25
|
Jessen SL, Friedemann MC, Mullen AE, Ginn-Hedman AM, Herting SM, Maitland DJ, Clubb FJ. Micro-CT and histopathology methods to assess host response of aneurysms treated with shape memory polymer foam-coated coils versus bare metal coil occlusion devices. J Biomed Mater Res B Appl Biomater 2020; 108:2238-2249. [PMID: 31961062 PMCID: PMC7379400 DOI: 10.1002/jbm.b.34561] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 12/04/2019] [Accepted: 01/07/2020] [Indexed: 11/06/2022]
Abstract
Recent studies utilizing shape memory polymer foams to coat embolizing coils have shown potential benefits over current aneurysm treatments. In the current study utilizing a rabbit-elastase aneurysm model, the performance of test article (foam-coated coil [FCC]) and control (bare platinum coils [BPCs]) devices were compared at 30, 90, and 180 days using micro-CT and histological assessments. The host response was measured by identifying the cells regionally present within the aneurysm, and assessing the degree of residual debris and connective tissue. The 3D reconstructions of aneurysms provided context for histologic findings, and aided in the overall aneurysm assessment. At all time points, >75% of the cells categorized in each aneurysm were associated with a bioactive yet biocompatible host response (vs. the remainder of cells that were associated with acute inflammation). The extracellular matrix exhibited a transition from residual fibrin at 30 days to a greater degree of connective tissue at 90 and 180 days. Although the control BPC-treated aneurysms exhibited a greater degree of connective tissue at the earliest time point examined (30 days), by 180 days, the FCC-treated aneurysms had more connective tissue and less debris overall than the control aneurysms. When considering cell types and extracellular matrix composition, the overall host response scores were significantly better in FCC-treated aneurysms at the later time point. Based on the results of these metrics, the FCC device may lead to an advanced tissue remodeling response over BPC occlusion devices.
Collapse
Affiliation(s)
- Staci L. Jessen
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Molly C. Friedemann
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas
| | - Annmarie E. Mullen
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | | | - Scott M. Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Fred J. Clubb
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| |
Collapse
|
26
|
Xiao R, Huang WM. Heating/Solvent Responsive Shape-Memory Polymers for Implant Biomedical Devices in Minimally Invasive Surgery: Current Status and Challenge. Macromol Biosci 2020; 20:e2000108. [PMID: 32567193 DOI: 10.1002/mabi.202000108] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 05/03/2020] [Indexed: 12/16/2022]
Abstract
This review is about the fundamentals and practical issues in applying both heating and solvent responsive shape memory polymers (SMPs) for implant biomedical devices via minimally invasive surgery. After revealing the general requirements in the design of biomedical devices based on SMPs and the fundamentals for the shape-memory effect in SMPs, the underlying mechanisms, characterization methods, and several representative biomedical applications, including vascular stents, tissue scaffolds, occlusion devices, drug delivery systems, and the current R&D status of them, are discussed. The new opportunities arising from emerging technologies, such as 3D printing, and new materials, such as vitrimer, are also highlighted. Finally, the major challenge that limits the practical clinical applications of SMPs at present is addressed.
Collapse
Affiliation(s)
- Rui Xiao
- Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, Department of Engineering Mechanics, Zhejiang University, Hangzhou, 310027, China
| | - Wei Min Huang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| |
Collapse
|
27
|
Wang CY, Hu J, Sheth RA, Oklu R. Emerging Embolic Agents in Endovascular Embolization: An Overview. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2020; 2:012003. [PMID: 34553126 PMCID: PMC8455112 DOI: 10.1088/2516-1091/ab6c7d] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Courtney Y. Wang
- The University of Texas Health Science Center at Houston, McGovern Medical School, 6431 Fannin St., Hourson, TX 77030, USA
| | - Jingjie Hu
- Division of Vascular and Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, AZ 85259, USA
| | - Rahul A. Sheth
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77054, USA
| | - Rahmi Oklu
- Division of Vascular and Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, AZ 85259, USA
| |
Collapse
|
28
|
Horn JD, Maitland DJ, Hartman J, Ortega JM. Computational study of clot formation in aneurysms treated with shape memory polymer foam. Med Eng Phys 2020; 75:65-71. [DOI: 10.1016/j.medengphy.2019.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 09/13/2019] [Accepted: 10/14/2019] [Indexed: 11/26/2022]
|
29
|
Jessen SL, Friedemann MC, Ginn-Hedman AM, Graul LM, Jokerst S, Robinson CB, Landsman TL, Clubb FJ, Maitland DJ. Microscopic Assessment of Healing and Effectiveness of a Foam-Based Peripheral Occlusion Device. ACS Biomater Sci Eng 2019; 6:2588-2599. [PMID: 32715083 DOI: 10.1021/acsbiomaterials.9b00895] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The IMPEDE Embolization Plug is a catheter-delivered vascular occlusion device that utilizes a porous shape memory polymer foam as a scaffold for thrombus formation and distal coils to anchor the device within the vessel. In this study, we investigated the biological response of porcine arteries to the IMPEDE device by assessing the extent of healing and overall effectiveness in occluding the vessel at 30, 60, and 90 days. Compared to control devices (Amplatzer Vascular Plug and Nester Embolization Coils), the host response to IMPEDE showed increased cellular infiltration (accommodated by the foam scaffold), which led to advanced healing of the initial thrombus to mature collagenous connective tissue (confirmed by transmission electron microscopy (TEM)). Over time, the host response to the IMPEDE device included degradation of the foam by multinucleated giant cells, which promoted fibrin and polymer degradation and advanced the healing response. Device effectiveness, in terms of vessel occlusion, was evaluated histologically by assessing the degree of recanalization. Although instances of recanalization were often observed at all time points for both control and test articles, the mature connective tissue within the foam scaffold of the IMPEDE devices improved percent vessel occlusion; when recanalization was observed in IMPEDE-treated vessels, channels were exclusively peri-device rather than intradevice, as often observed in the controls, and the vessels mostly remained >75% occluded. Although total vessel occlusion provides the optimal ischemic effect, in cardiovascular pathology, there is a progressive ischemic effect on the downstream vasculature as a vessel narrows. As such, we expect a sustained ischemic therapeutic effect to be observed in vessels greater than 75% occluded. Overall, the current study suggests the IMPEDE device presents advantages over controls by promoting an enhanced degree of healing within the foam scaffold, which decreases the likelihood of intradevice recanalization and ultimately may lead to a sustained ischemic therapeutic effect.
Collapse
Affiliation(s)
- Staci L Jessen
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Molly C Friedemann
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States
| | - Anne-Marie Ginn-Hedman
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Lance M Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Steven Jokerst
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Cedric B Robinson
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States
| | - Todd L Landsman
- Shape Memory Medical Inc., Santa Clara, California 95054, United States
| | - Fred J Clubb
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States.,Shape Memory Medical Inc., Santa Clara, California 95054, United States
| |
Collapse
|
30
|
Hu J, Albadawi H, Oklu R, Chong BW, Deipolyi AR, Sheth RA, Khademhosseini A. Advances in Biomaterials and Technologies for Vascular Embolization. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1901071. [PMID: 31168915 PMCID: PMC7014563 DOI: 10.1002/adma.201901071] [Citation(s) in RCA: 98] [Impact Index Per Article: 19.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/24/2019] [Indexed: 05/03/2023]
Abstract
Minimally invasive transcatheter embolization is a common nonsurgical procedure in interventional radiology used for the deliberate occlusion of blood vessels for the treatment of diseased or injured vasculature. A wide variety of embolic agents including metallic coils, calibrated microspheres, and liquids are available for clinical practice. Additionally, advances in biomaterials, such as shape-memory foams, biodegradable polymers, and in situ gelling solutions have led to the development of novel preclinical embolic agents. The aim here is to provide a comprehensive overview of current and emerging technologies in endovascular embolization with respect to devices, materials, mechanisms, and design guidelines. Limitations and challenges in embolic materials are also discussed to promote advancement in the field.
Collapse
Affiliation(s)
- Jingjie Hu
- Division of Vascular & Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Hassan Albadawi
- Division of Vascular & Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Rahmi Oklu
- Division of Vascular & Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Brian W Chong
- Departments of Radiology and Neurological Surgery, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Amy R. Deipolyi
- Department of Interventional Radiology, Memorial Sloan Kettering Cancer Center, Weill Cornell Medical Center, 1275 York Avenue, New York, New York 10065, USA
| | - Rahul A. Sheth
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054, USA
| | - Ali Khademhosseini
- Department of Bioengineering, Department of Radiological Sciences, Department of Chemical and Biomolecular Engineering, Center for Minimally Invasive Therapeutics, California Nanosystems Institute, University of California, 410 Westwood Plaza, Los Angeles, California 90095, USA
| |
Collapse
|
31
|
Easley AD, Monroe MBB, Hasan SM, Weems AC, Frederick J, Maitland DJ. Shape memory polyurethane-urea foams with improved toughness. J Appl Polym Sci 2019; 136:47268. [PMID: 32724263 PMCID: PMC7386400 DOI: 10.1002/app.47268] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 10/04/2018] [Indexed: 11/08/2022]
Abstract
Current vascular aneurysm treatments often require either highly invasive strategy to surgically occlude an aneurysm or endovascular occlusion via metal coils. While endovascular coils are safer, they have limited efficacy. Endovascular coils that are integrated with shape memory polymer (SMP) foams have the potential to improve occlusion and reduce coil risks; however, the mechanical performance and limited homogeneity of SMP foams can hinder their effective use. To address this issue, SMP foams are synthesized using the monomer diethanolamine (DEA) in place of triethanolamine (TEA) to provide improved mechanical properties for medical device applications. Mechanical testing and micro-fracture analysis were performed on DEA and TEA foams. DEA foams show improved toughness and reduced micro-fractures compared to the control. This work presents the utility of DEA in SMP synthesis to enable the potential production of safer aneurysm treatment.
Collapse
Affiliation(s)
- Alexandra D Easley
- Biomedical Device Laboratory, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120
| | - Mary Beth Browning Monroe
- Biomedical Device Laboratory, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120
| | - Sayyeda M Hasan
- Biomedical Device Laboratory, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120
| | - Andrew C Weems
- Biomedical Device Laboratory, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120
| | - Jane Frederick
- Biomedical Device Laboratory, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120
| | - Duncan J Maitland
- Biomedical Device Laboratory, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120
| |
Collapse
|
32
|
Herting SM, Ding Y, Boyle AJ, Dai D, Nash LD, Asnafi S, Jakaitis DR, Johnson CR, Graul LM, Yeh C, Kallmes DF, Kadirvel R, Maitland DJ. In vivo comparison of shape memory polymer foam-coated and bare metal coils for aneurysm occlusion in the rabbit elastase model. J Biomed Mater Res B Appl Biomater 2019; 107:2466-2475. [PMID: 30775843 DOI: 10.1002/jbm.b.34337] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Revised: 01/17/2019] [Accepted: 01/26/2019] [Indexed: 11/09/2022]
Abstract
Shape memory polymer (SMP) foam-coated coils (FCCs) are new embolic coils coated with porous SMP designed to expand for increased volume filling and enhanced healing after implantation. The purpose of this study was to compare chronic aneurysm healing after treatment with SMP FCCs to bare platinum coil (BPC) controls in the rabbit elastase aneurysm model. BPCs or SMP FCCs were implanted in rabbit elastase-induced aneurysms for follow-up at 30 days (n = 10), 90 days (n = 5), and 180 days (n = 12 for BPCs; n = 14 for SMP FCCs). Aneurysm occlusion and histologic healing, including a qualitative healing score, neointima thickness, collagen deposition, and inflammation were compared between the two groups. The mean neointima thickness was significantly greater in groups treated with SMP FCCs for all three time points. Histologic healing scores and collagen deposition quantification suggested that aneurysms treated with SMP FCCs experience more complete healing of the dome by 90 days, but the differences were not statistically significant. More progressive occlusion and recanalization were observed in aneurysms treated with SMP FCCs, but neither difference was statistically significant. Additionally, the SMP foam used in the FCCs was found to degrade faster in the rabbit elastase model than expected based on previous studies in a porcine sidewall aneurysm model. This study suggests that SMP FCCs can promote neointima formation along the aneurysm neck, and may lead to more complete healing of the dome and neck. These findings indicate potential benefits of this device for aneurysm occlusion procedures. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B:2466-2475, 2019.
Collapse
Affiliation(s)
- Scott M Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Yonghong Ding
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Anthony J Boyle
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas.,Shape Memory Medical, Santa Clara, California
| | - Daying Dai
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Landon D Nash
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas.,Shape Memory Medical, Santa Clara, California
| | - Solmaz Asnafi
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Daniel R Jakaitis
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Collin R Johnson
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Lance M Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Chung Yeh
- Shape Memory Medical, Santa Clara, California
| | - David F Kallmes
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Ramanathan Kadirvel
- Neuroradiology Research Laboratory, Department of Radiology, Mayo Clinic, Rochester, Minnesota
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas.,Shape Memory Medical, Santa Clara, California
| |
Collapse
|
33
|
Weems AC, Easley A, Roach SR, Maitland DJ. Highly Cross-Linked Shape Memory Polymers with Tunable Oxidative and Hydrolytic Degradation Rates and Selected Products Based on Succinic Acid. ACS APPLIED BIO MATERIALS 2018; 2:454-463. [PMID: 32832879 DOI: 10.1021/acsabm.8b00650] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Minimally invasive medical devices are of great interest, with shape memory polymers (SMPs) representing one such possibility for producing these devices. Previous work with low density, highly porous SMPs has demonstrated oxidative degradation, while attempts to incorporate hydrolytic degradation have resulted in rapidly decreasing glass transition temperature (T g ), ultimately preventing strain fixity of the materials at clinically relevant temperatures. Through esterification of the amino alcohol triethanolamine, an alcohol containing network was synthesized and incorporated into SMPs. These ester networks were used to control the bulk morphology of the SMP, with the T g remaining above 37 °C when 50% of the alcohol was contributed by the ester network. This methodology also yielded SMPs that could degrade through both hydrolysis and oxidation; by oxidation, the SMPs degrade at a similar rate as the control materials (0.2%/day mass) for the first 30 days, at which point the rate changes to 3.5%/day until the samples become too fragile to examine at 80 days. By comparison, control materials have lost approximately 30% of mass by 140 days, at a constant rate of degradation, demonstrating that the ester SMPs are a promising material system for producing more rapidly degradable, soft, porous biomaterials.
Collapse
Affiliation(s)
- Andrew C Weems
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77840, United States
| | - Alexandra Easley
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77840, United States
| | - Sydney Reese Roach
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77840, United States
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77840, United States
| |
Collapse
|
34
|
Abraham AA, Means AK, Clubb FJ, Fei R, Locke AK, Gacasan EG, Coté GL, Grunlan MA. Foreign Body Reaction to a Subcutaneously Implanted Self-Cleaning, Thermoresponsive Hydrogel Membrane for Glucose Biosensors. ACS Biomater Sci Eng 2018; 4:4104-4111. [PMID: 31633011 DOI: 10.1021/acsbiomaterials.8b01061] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Towards achieveing a subcutaneously implanted glucose biosensor with long-term functionality, a thermoresponsive membrane previously shown to have potential to house a glucose sensing assay was evaluated herein for its ability to minimize the foriegn body reaction (FBR) and the resulting fibrous capsule. The severity of the FBR proportionally reduces diffusion of glucose to the sensor and hence sensor lifetime. However, efforts to reduce the FBR have largedly focused on anti-fouling materials that passively inhibit cellular attachment, particularly poly(ethylene glycol) (PEG). Herein, the extent of the FBR of a subcutaneously implanted "self-cleaning" cylindrical membrane was analyzed in rodents. This membrane represents an "actively anti-fouling" approach to reduce cellular adhesion. It is a thermoresponsive double network nanocomposite hydrogel (DNNC) comprised of poly(N-isopropylacrylamide) (PNIPAAm) and embedded polysiloxane nanoparticles. The membrane's cyclical deswelling/reswelling response to local body temperature fluctuations was anticipated to limit cellular accumulation. Indeed, after 30 days, the self-cleaning membrane exhibited a notably thin fibrous capsule (~30 µm) and increased microvascular density within 1 mm of the implant surface in comparison to a non-thermoresponsive, benchmark biocompatible control (PEG diacrylate, PEG-DA).
Collapse
Affiliation(s)
- Alexander A Abraham
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - A Kristen Means
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843 (USA)
| | - Fred J Clubb
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA).,Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77843-4467 (USA)
| | - Ruochong Fei
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - Andrea K Locke
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - Erica G Gacasan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA).,Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843-3577 (USA)
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA).,Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843 (USA).,Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843-3577 (USA)
| |
Collapse
|
35
|
Weems AC, Li W, Maitland DJ, Calle LM. Polyurethane Microparticles for Stimuli Response and Reduced Oxidative Degradation in Highly Porous Shape Memory Polymers. ACS APPLIED MATERIALS & INTERFACES 2018; 10:32998-33009. [PMID: 30184426 PMCID: PMC7433764 DOI: 10.1021/acsami.8b11082] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Shape memory polymers (SMPs) have been found to be promising biomaterials for a variety of medical applications; however, the clinical translation of such technology is dependent on tailorable properties such as gravimetric changes in degradation environments. For SMPs synthesized from amino-alcohols, oxidation resulting in rapid mass loss may be problematic in terms of loss of material functionality as well as toxicity and cytocompatibility concerns. Control of gravimetric changes was achieved through the incorporation of small molecule antioxidants, either directly into the polymer matrix or included in microparticles to form a SMP composite material. With direct incorporation of small molecule phenolic antioxidant 2,2'-methylenebis(6- tert-butyl)-methylphenol (Methyl), SMPs displayed reduce strain recovery by more than 50% (Methyl) and increase elastic modulus from approximately 1.4 to 2.3 MPa, at the expense of the strain to failure being reduced from 45% to 32%. Importantly, such changes could not ensure retention of the antioxidants and therefore did not increase oxidative stability beyond 15 days in accelerated oxidative conditions (equivalent to approximately 800 days in porcine aneurysms) in all cases except for the inclusion of a hindered amine that capped network growth, which also resulted in shape memory reduction (only 80% recoverable strain achieved). However, the inclusion of antioxidants in microparticles was found to produce materials with similar thermomechanical ( Tg migration below 1.0 °C) and shape recovery of 100%, while increasing oxidative resistance compared to controls (oxidation onset was delayed by 3 days and material lifespan increased to approximately 20-22 days in accelerated oxidative solution or beyond 1000 days in the porcine aneurysm). The microparticle composite SMPs also act as a platform for environmental sensing, such as pH-dependent fluorescence shifts and payload release, as demonstrated by fluorescent dye studies using phloxine B and nile blue chloride and the release of antioxidants over a 3 week period. The use of polyurethane-urea microparticles in porous SMPs is demonstrated to increase biostability of the materials, by approximately 25%, and ultimately extend their lifespan for use in aneurysm occlusion as determined through calculated in vivo degradation rates corresponding to a porcine aneurysm environment.
Collapse
Affiliation(s)
- A. C. Weems
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77840, United States
| | - W. Li
- Corrosion Technology Laboratory, NASA, Kennedy Space Center, Florida 32899, United States
| | - D. J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77840, United States
| | - L. M. Calle
- Corrosion Technology Laboratory, NASA, Kennedy Space Center, Florida 32899, United States
| |
Collapse
|
36
|
Horn JD, Maitland DJ, Hartman J, Ortega JM. A computational thrombus formation model: application to an idealized two-dimensional aneurysm treated with bare metal coils. Biomech Model Mechanobiol 2018; 17:1821-1838. [DOI: 10.1007/s10237-018-1059-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 07/21/2018] [Indexed: 10/28/2022]
|
37
|
Monroe MBB, Easley AD, Grant K, Fletcher GK, Boyer C, Maitland DJ. Multifunctional Shape-Memory Polymer Foams with Bio-inspired Antimicrobials. Chemphyschem 2017; 19:1999-2008. [PMID: 29282877 DOI: 10.1002/cphc.201701015] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Indexed: 11/09/2022]
Abstract
Despite a number of clinically available hemostats, uncontrolled bleeding is the primary cause of trauma-related death. Shape-memory polymer (SMP) foams have a number of desirable properties for use as hemostats, including shape recovery to enable delivery into bleed sites, biocompatibility, and rapid blood clotting. To expand upon this material system, the current work aims to incorporate phenolic acids, which are honey-based antimicrobial agents, into SMP foams. We showed that cinnamic acid (CA) can be utilized as a monomer in SMP synthesis to provide foams with comparable pore structure and retained cytocompatibility. The addition of CA enabled tuning of thermal and shape-memory properties within clinically relevant ranges. Furthermore, the modified foams demonstrated initial and sustained antimicrobial effects against gram-positive and gram-negative bacteria. These multifunctional scaffolds demonstrate potential for use as hemostats to improve upon current hemorrhage treatments and provide a new tool in tuning the biological and material properties of SMP foams.
Collapse
Affiliation(s)
- Mary Beth Browning Monroe
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX, 77843-3120, USA
| | - Alexandra D Easley
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX, 77843-3120, USA
| | - Katie Grant
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX, 77843-3120, USA
| | - Grace K Fletcher
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX, 77843-3120, USA
| | - Calla Boyer
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX, 77843-3120, USA
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX, 77843-3120, USA
| |
Collapse
|
38
|
Boyle AJ, Wierzbicki MA, Herting S, Weems AC, Nathan A, Hwang W, Maitland DJ. In vitro performance of a shape memory polymer foam-coated coil embolization device. Med Eng Phys 2017; 49:56-62. [PMID: 28774685 PMCID: PMC5819332 DOI: 10.1016/j.medengphy.2017.07.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 07/17/2017] [Indexed: 01/21/2023]
Abstract
Intracranial saccular aneurysm treatment using endovascular embolization devices are limited by aneurysm recurrence that can lead to aneurysm rupture. A shape memory polymer (SMP) foam-coated coil (FCC) embolization device was designed to increase packing density and improve tissue healing compared to current commercial devices. FCC devices were fabricated and tested using in vitro models to assess feasibility for clinical treatment of intracranial saccular aneurysms. FCC devices demonstrated smooth delivery through tortuous pathways similar to control devices as well as greater than 10 min working time for clinical repositioning during deployment. Furthermore, the devices passed pilot verification tests for particulates, chemical leachables, and cytocompatibility. Finally, devices were successfully implanted in an in vitro saccular aneurysm model with large packing density. Though improvements and future studies evaluating device stiffness were identified as a necessity, the FCC device demonstrates effective delivery and packing performance that provides great promise for clinical application of the device in treatment of intracranial saccular aneurysms.
Collapse
Affiliation(s)
- Anthony J Boyle
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA; Shape Memory Medical, Inc., College Station, TX, USA
| | - Mark A Wierzbicki
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA; Shape Memory Medical, Inc., College Station, TX, USA
| | - Scott Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Andrew C Weems
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Adam Nathan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Wonjun Hwang
- Shape Memory Medical, Inc., College Station, TX, USA
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA.
| |
Collapse
|
39
|
Nash LD, Browning Monroe MB, Ding YH, Ezell KP, Boyle AJ, Kadirvel R, Kallmes DF, Maitland DJ. Increased X-ray Visualization of Shape Memory Polymer Foams by Chemical Incorporation of Iodine Motifs. Polymers (Basel) 2017; 9. [PMID: 30034862 PMCID: PMC6052870 DOI: 10.3390/polym9080381] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Shape memory polymers can be programmed into a secondary geometry and recovered to their primary geometry with the application of a controlled stimulus. Porous shape memory polymer foam scaffolds that respond to body temperature show particular promise for embolic medical applications. A limitation for the minimally invasive delivery of these materials is an inherent lack of X-ray contrast. In this work, a triiodobenzene containing a monomer was incorporated into a shape memory polymer foam material system to chemically impart X-ray visibility and increase material toughness. Composition and process changes enabled further control over material density and thermomechanical properties. The proposed material system demonstrates a wide range of tailorable functional properties for the design of embolic medical devices, including X-ray visibility, expansion rate, and porosity. Enhanced visualization of these materials can improve the acute performance of medical devices used to treat vascular malformations, and the material porosity provides a healing scaffold for durable occlusion.
Collapse
Affiliation(s)
- Landon D. Nash
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Mary Beth Browning Monroe
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Yong-Hong Ding
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (Y.-H.D.); (R.K.); (D.F.K.)
| | - Kendal P. Ezell
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Anthony J. Boyle
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Ramanathan Kadirvel
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (Y.-H.D.); (R.K.); (D.F.K.)
| | - David F. Kallmes
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (Y.-H.D.); (R.K.); (D.F.K.)
| | - Duncan J. Maitland
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
- Correspondence: ; Tel.: +1-979-458-3471
| |
Collapse
|
40
|
Muschalek R, Nash L, Jones R, Hasan SM, Keller BK, Monroe MBB, Maitland DJ. Effects of Sterilization on Shape Memory Polyurethane Embolic Foam Devices. J Med Device 2017; 11:0310111-310119. [PMID: 29034056 DOI: 10.1115/1.4037052] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 05/09/2017] [Indexed: 11/08/2022] Open
Abstract
Polyurethane shape memory polymer (SMP) foams have been developed for various embolic medical devices due to their unique properties in minimally invasive biomedical applications. These polyurethane materials can be stored in a secondary shape, from which they can recover their primary shape after exposure to an external stimulus, such as heat and water exposure. Tailored actuation temperatures of SMPs provide benefits for minimally invasive biomedical applications, but incur significant challenges for SMP-based medical device sterilization. Most sterilization methods require high temperatures or high humidity to effectively reduce the bioburden of the device, but the environment must be tightly controlled after device fabrication. Here, two probable sterilization methods (nontraditional ethylene oxide (ntEtO) gas sterilization and electron beam irradiation) are investigated for SMP medical devices. Thermal characterization of the sterilized foams indicated that ntEtO gas sterilization significantly decreased the glass transition temperature. Further material characterization was undertaken on the electron beam (ebeam) sterilized samples, which indicated minimal changes to the thermomechanical integrity of the bulk foam and to the device functionality.
Collapse
Affiliation(s)
- Rachael Muschalek
- Biomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail:
| | - Landon Nash
- Biomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail:
| | - Ryan Jones
- Biomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail:
| | - Sayyeda M Hasan
- Biomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail:
| | - Brandis K Keller
- Biomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail:
| | - Mary Beth B Monroe
- Biomedical Engineering, Texas A&M University, College Station, TX 77843 e-mail:
| | - Duncan J Maitland
- Biomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail:
| |
Collapse
|
41
|
Nathan AL, Fletcher GK, Monroe MBB, Hwang W, Herting SM, Hasan SM, Keller BK, Maitland DJ. Particulate Release From Nanoparticle-Loaded Shape Memory Polymer Foams. J Med Device 2017; 11:0110091-110099. [PMID: 28179975 DOI: 10.1115/1.4035547] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Revised: 12/07/2016] [Indexed: 11/08/2022] Open
Abstract
Highly porous, open-celled shape memory polymer (SMP) foams are being developed for a number of vascular occlusion devices. Applications include abdominal aortic and neurovascular aneurysm or peripheral vascular occlusion. A major concern with implanting these high surface area materials in the vasculature is the potential to generate unacceptable particulate burden, in terms of number, size, and composition. This study demonstrates that particulate numbers and sizes in SMP foams are in compliance with limits stated by the most relevant standard and guidance documents. Particulates were quantified in SMP foams as made, postreticulation, and after incorporating nanoparticles intended to increase material toughness and improve radiopacity. When concentrated particulate treatments were administered to fibroblasts, they exhibited high cell viability (100%). These results demonstrate that the SMP foams do not induce an unacceptable level of risk to potential vascular occlusion devices due to particulate generation.
Collapse
Affiliation(s)
- Adam L Nathan
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Grace K Fletcher
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | | | - Wonjun Hwang
- Shape Memory Medical, Inc., Santa Clara, CA 95054
| | - Scott M Herting
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Sayyeda M Hasan
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Brandis K Keller
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Duncan J Maitland
- Biomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail:
| |
Collapse
|