Concannon J, Máirtín EÓ, FitzGibbon B, Hynes N, Sultan S, McGarry JP. On the Importance of Including Cohesive Zone Models in Modelling Mixed-Mode Aneurysm Rupture. Cardiovasc Eng Technol 2024:10.1007/s13239-024-00740-3. [PMID: 38987509 DOI: 10.1007/s13239-024-00740-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 06/21/2024] [Indexed: 07/12/2024]
Abstract
INTRODUCTION The precise mechanism of rupture in abdominal aortic aneurysms (AAAs) has not yet been uncovered. The phenomenological failure criterion of the coefficient of proportionality between von Mises stress and tissue strength does not account for any mechanistic foundation of tissue fracture. Experimental studies have shown that arterial failure is a stepwise process of fibrous delamination (mode II) and kinking (mode I) between layers. Such a mechanism has not previously been considered for AAA rupture. METHODS In the current study we consider both von Mises stress in the wall, in addition to interlayer tractions and delamination using cohesive zone models. Firstly, we present a parametric investigation of the influence of a range of AAA anatomical features on the likelihood of elevated interlayer traction and delamination. RESULTS We observe in several cases that the location of peak von Mises stress and tangential traction coincide. Our simulations also reveal however, that peak von Mises and intramural tractions are not coincident for aneurysms with Length/Radius less than 2 (short high-curvature aneurysms) and for aneurysms with symmetric intraluminal thrombus (ILT). For an aneurysm with (L/R = 2.0), the peak σ vm moves slightly towards the origin while the peak T t is near the peak bulge with a separation distance of ~ 17 mm. Additionally, we present three patient-specific AAA models derived directly from CT scans, which also illustrate that the location of von Mises stress does not correlate with the point of interlayer delamination. CONCLUSION This study suggests that incorporating cohesive zone models into clinical based FE analyses may capture a greater proportion of ruptures in-silico.
Collapse
Affiliation(s)
- J Concannon
- Biomedical Engineering, University of Galway, Galway, Ireland.
| | - E Ó Máirtín
- Biomedical Engineering, University of Galway, Galway, Ireland
| | - B FitzGibbon
- Biomedical Engineering, University of Galway, Galway, Ireland
| | - N Hynes
- Department of Vascular and Endovascular Surgery, Galway University Hospitals, Galway, Ireland
| | - S Sultan
- Department of Vascular and Endovascular Surgery, Galway University Hospitals, Galway, Ireland
| | - J P McGarry
- Biomedical Engineering, University of Galway, Galway, Ireland
| |
Collapse
|
2
|
Petelinšek N, Mommer S. Tough Hydrogels for Load-Bearing Applications. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307404. [PMID: 38225751 DOI: 10.1002/advs.202307404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/08/2023] [Indexed: 01/17/2024]
Abstract
Tough hydrogels have emerged as a promising class of materials to target load-bearing applications, where the material has to resist multiple cycles of extreme mechanical impact. A variety of chemical interactions and network architectures are used to enhance the mechanical properties and fracture mechanics of hydrogels making them stiffer and tougher. In recent years, the mechanical properties of tough, high-performance hydrogels have been benchmarked, however, this is often incomplete as important variables like water content are largely ignored. In this review, the aim is to clarify the reported mechanical properties of state-of-the-art tough hydrogels by providing a comprehensive library of fracture and mechanical property data. First, common methods for mechanical characterization of such high-performance hydrogels are introduced. Then, various modes of energy dissipation to obtain tough hydrogels are discussed and used to categorize the individual datasets helping to asses the material's (fracture) mechanical properties. Finally, current applications are considered, tough high-performance hydrogels are compared with existing materials, and promising future opportunities are discussed.
Collapse
Affiliation(s)
- Nika Petelinšek
- Macromolecular Engineering Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
| | - Stefan Mommer
- Macromolecular Engineering Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland
| |
Collapse
|
3
|
Ghadie NM, Labrosse MR, St-Pierre JP. Glycosaminoglycans modulate compressive stiffness and circumferential residual stress in the porcine thoracic aorta. Acta Biomater 2023; 170:556-566. [PMID: 37683966 DOI: 10.1016/j.actbio.2023.08.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 08/26/2023] [Accepted: 08/31/2023] [Indexed: 09/10/2023]
Abstract
The mechanical properties of the aorta are influenced by the extracellular matrix, a network mainly comprised of fibers and glycosaminoglycans (GAG). In this work, we demonstrate that GAG contribute to the opening angle (a marker of circumferential residual stresses) in intact and glycated aortic tissue. Enzymatic GAG depletion was associated with a decrease in the opening angle, by approximately 25% (p = 0.009) in the ascending (AS) region, 32% (p = 0.003) in the aortic arch (AR), and 42% (p = 0.001) in the lower descending thoracic (LDT) region. A similar effect of GAG depletion on aortic ring opening angle was also observed in previously glycated tissues. Using indentation testing, we found that the radial compressive stiffness significantly increased in the AS region following GAG depletion, compared to fresh (p = 0.006) and control samples (p = 0.021), and that the compressive properties are heterogeneous along the aortic tree. A small loss of water content was also detected after GAG depletion, which was most prominent under hypotonic conditions. Finally, the AS region was also associated with a significant loss of compressive deformation (circumferential stretch that is < 1) in the inner layer of the aorta following GAG depletion, suggesting that GAG interact with ECM fibers in their effect on aortic mechanics. The importance of this work lies in its identification of the role of GAG in modulating the mechanical properties of the aorta, namely the circumferential residual stresses and the radial compressive stiffness, as well as contributing to the swelling state and the level of circumferential prestretch in the tissue. STATEMENT OF SIGNIFICANCE: The mechanical properties of the aorta are influenced by the composition and organization of its extracellular matrix (ECM) and are highly relevant to medical conditions affecting the structural integrity of the aorta. The extent of contribution of glycosaminoglycans (GAG), a relatively minor ECM component, to the mechanical properties of the aorta, remains poorly characterized. This works shows that GAG contribute on average 30% to the opening angle (an indicator of circumferential residual stresses) of porcine aortas, and that GAG-depletion is associated with an increased radial compressive stiffness of the aorta. GAG-depletion was also associated with a loss of water content and compressive deformation in the inner layers of the aortic wall providing insight into potential mechanisms for their biomechanical role.
Collapse
Affiliation(s)
- Noor M Ghadie
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N6N5, Canada
| | - Michel R Labrosse
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N6N5, Canada; Department of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, ON K1Y4W7, Canada
| | - Jean-Philippe St-Pierre
- Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, ON K1N6N5, Canada.
| |
Collapse
|
4
|
Alloisio M, Gasser TC. Fracture of the porcine aorta. Part 2: FEM modelling and inverse parameter identification. Acta Biomater 2023:S1742-7061(23)00345-8. [PMID: 37422007 DOI: 10.1016/j.actbio.2023.06.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 06/14/2023] [Accepted: 06/15/2023] [Indexed: 07/10/2023]
Abstract
The mechanics of vascular tissue, particularly its fracture properties, are crucial in the onset and progression of vascular diseases. Vascular tissue properties are complex, and the identification of fracture mechanical properties relies on robust and efficient numerical tools. In this study, we propose a parameter identification pipeline to extract tissue properties from force-displacement and digital image correlation (DIC) data. The data has been acquired by symconCT testing porcine aorta wall specimens. Vascular tissue is modelled as a non-linear viscoelastic isotropic solid, and an isotropic cohesive zone model describes tissue fracture. The model closely replicated the experimental observations and identified the fracture energies of 1.57±0.82 kJ m-2 and 0.96±0.34 kJ m-2 for rupturing the porcine aortic media along the axial and circumferential directions, respectively. The identified strength was always below 350 kPa, a value significantly lower than identified through classical protocols, such as simple tension, and sheds new light on the resilience of the aorta. Further refinements to the model, such as considering rate effects in the fracture process zone and tissue anisotropy, could have improved the simulation results. STATEMENT OF SIGNIFICANCE: This paper identified porcine aorta's biomechanical properties using data acquired through a previously developed experimental protocol, the symmetry-constraint compact tension test. An implicit finite element method model mimicked the test, and a two-step approach identified the material's elastic and fracture properties directly from force-displacement curves and digital image correlation-based strain measurements. Our findings show a lower strength of the abdominal aorta as compared to the literature, which may have significant implications for the clinical evaluation of the risk of aortic rupture.
Collapse
Affiliation(s)
- Marta Alloisio
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - T Christian Gasser
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden.
| |
Collapse
|
5
|
Alloisio M, Chatziefraimidou M, Roy J, Christian Gasser T. Fracture of the porcine aorta. Part 1: symconCT fracture testing and DIC. Acta Biomater 2023:S1742-7061(23)00347-1. [PMID: 37355178 DOI: 10.1016/j.actbio.2023.06.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/26/2023]
Abstract
Tissue failure and damage are inherent parts of vascular diseases and tightly linked to clinical events. Additionally, experimental set-ups designed to study classical engineering materials are suboptimal in the exploration of vessel wall fracture properties. The classical Compact Tension (CT) test was augmented to enable stable fracture propagation, resulting in the symmetry-constraint Compact Tension (symconCT) test, a suitable set-up for fracture testing of vascular tissue. The test was combined with Digital Image Correlation (DIC) to study tissue fracture in 45 porcine aorta specimens. Test specimens were loaded in axial and circumferential directions in a physiological solution at 37∘ C. Loading the aortic vessel wall in the axial direction resulted in mode I tissue failure and a fracture path aligned with the circumferential vessel direction. Circumferential loading resulted in mode I-dominated failure with multiple deflections of the fracture path. The aorta ruptured at a principal Green-Lagrange strain of approximately 0.7, and strain rate peaks that develop ahead of the crack tip reached nearly 400 times the strain rate on average over the test specimen. It required approximately 70% more external work to fracture the aorta by circumferential than axial load; normalised with the fracture surface, similar energy levels are, however, observed. The symconCT test resulted in a stable fracture propagation, which, combined with DIC, provided a set-up for the in-depth analysis of vascular tissue failure. The high strain rates ahead of the crack tip indicate the significance of rate effects in the constitutive description of vascular tissue fracture. STATEMENT OF SIGNIFICANCE: This paper represents a significant step forward in understanding the fracture properties of porcine aorta. Inspired by the Compact Tension test, we developed an ad hoc experimental protocol to investigate stable crack propagation in soft materials, providing new insights into the mechanical processes that lead to the rupture of vascular tissue. The set-up enables the assessment of strains and strain rates ahead of the crack tip, and our findings could improve the clinical risk assessment of vascular pathologies as well as optimize medical device design.
Collapse
Affiliation(s)
- Marta Alloisio
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Marina Chatziefraimidou
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Joy Roy
- Department of Molecular Medicine and Surgery, KI Karolinska Institute, Sweden
| | - T Christian Gasser
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden.
| |
Collapse
|
6
|
Sokolis DP. Layer-Specific Tensile Strength of the Human Aorta: Segmental Variations. J Biomech Eng 2023; 145:1156346. [PMID: 36691824 DOI: 10.1115/1.4056748] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 01/18/2023] [Indexed: 01/25/2023]
Abstract
Knowledge of the failure properties of the aorta is essential to understand the mechanisms of dissection and rupture. Limited information is, however, available in humans or experimental animals about the layer-specific properties and their segmental variations have not been determined. In this paper, the failure properties of the intima, media, and adventitia were studied in nine consecutive aortic segments and two principal directions. Detailed biomechanical tests were performed with a tensile-testing device on 756 layer strips, harvested from fourteen cadaveric subjects aged 21-82 years. Intimal and medial strength in either direction remained invariant along the aorta, and their extensibility longitudinally decreased, whereas adventitial strength and extensibility longitudinally increased, explaining why the preferential sites for the development of aortic dissection or traumatic rupture are in the proximal aorta. The media was stronger circumferentially than longitudinally in all segments, accounting for the typically transverse tearing in dissection/rupture. The adventitial properties were significantly higher than the intimal and medial in most segments. Still, the intima had similar strength but lower extensibility compared to the media in both directions, and higher maximum stiffness longitudinally in several segments. The rupture surface of all layers was not perpendicular to the loading axis, more so in the circumferential strips compared to longitudinal ones. Aging impaired the extensibility and strength of all layers, particularly the media, but did not affect the maximum stiffness and rupture-surface direction. Females were rarely associated with different failure properties compared to age-matched males.
Collapse
Affiliation(s)
- Dimitrios P Sokolis
- Laboratory of Biomechanics, Center of Clinical, Experimental Surgery, and Translational Research, Biomedical Research Foundation of the Academy of Athens, 4 Soranou Ephesiou Street, Athens 115 27, Greece
| |
Collapse
|
7
|
Wang R, Mattson JM, Zhang Y. Effect of aging on the biaxial mechanical behavior of human descending thoracic aorta: Experiments and constitutive modeling considering collagen crosslinking. J Mech Behav Biomed Mater 2023; 140:105705. [PMID: 36758423 PMCID: PMC10023391 DOI: 10.1016/j.jmbbm.2023.105705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 01/20/2023] [Accepted: 02/01/2023] [Indexed: 02/05/2023]
Abstract
Collagen crosslinking, an important contributor to the stiffness of soft tissues, was found to increase with aging in the aortic wall. Here we investigated the mechanical properties of human descending thoracic aorta with aging and the role of collagen crosslinking through a combined experimental and modeling approach. A total of 32 samples from 17 donors were collected and divided into three age groups: <40, 40-60 and > 60 years. Planar biaxial tensile tests were performed to characterize the anisotropic mechanical behavior of the aortic samples. A recently developed constitutive model incorporating collagen crosslinking into the two-fiber family model (Holzapfel and Ogden, 2020) was modified to accommodate biaxial deformation of the aorta, in which the extension and rotation kinematics of bonded fibers and crosslinks were decoupled. The mechanical testing results show that the aorta stiffens with aging with a more drastic change in the longitudinal direction, which results in altered aortic anisotropy. Our results demonstrate a good fitting capability of the constitutive model considering crosslinking for the biaxial aortic mechanics of all age groups. Furthermore, constitutive modeling results suggest an increased contribution of crosslinking and strain energy density to the biaxial stress-stretch behaviors with aging and point to excessive crosslinking as a prominent contributor to aortic stiffening.
Collapse
Affiliation(s)
- Ruizhi Wang
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
| | - Jeffrey M Mattson
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
| | - Yanhang Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA; Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA; Divison of Materials Science & Engineering, Boston University, Boston, MA, 02215, USA.
| |
Collapse
|
8
|
Zeng L, Liu F, Yu Q, Jin C, Yang J, Suo Z, Tang J. Flaw-insensitive fatigue resistance of chemically fixed collagenous soft tissues. SCIENCE ADVANCES 2023; 9:eade7375. [PMID: 36867693 PMCID: PMC9984180 DOI: 10.1126/sciadv.ade7375] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 01/31/2023] [Indexed: 06/18/2023]
Abstract
Bovine pericardium (BP) has been used as leaflets of prosthetic heart valves. The leaflets are sutured on metallic stents and can survive 400 million flaps (~10-year life span), unaffected by the suture holes. This flaw-insensitive fatigue resistance is unmatched by synthetic leaflets. We show that the endurance strength of BP under cyclic stretch is insensitive to cuts as long as 1 centimeter, about two orders of magnitude longer than that of a thermoplastic polyurethane (TPU). The flaw-insensitive fatigue resistance of BP results from the high strength of collagen fibers and soft matrix between them. When BP is stretched, the soft matrix enables a collagen fiber to transmit tension over a long length. The energy in the long length dissipates when the fiber breaks. We demonstrate that a BP leaflet greatly outperforms a TPU leaflet. It is hoped that these findings will aid the development of soft materials for flaw-insensitive fatigue resistance.
Collapse
Affiliation(s)
- Liangsong Zeng
- State Key Lab for Strength and Vibration of Mechanical Structures, International Center for Applied Mechanics, Department of Engineering Mechanics, Xi’an Jiaotong University, Xi’an, China
| | - Fengkai Liu
- State Key Lab for Strength and Vibration of Mechanical Structures, International Center for Applied Mechanics, Department of Engineering Mechanics, Xi’an Jiaotong University, Xi’an, China
| | - Qifeng Yu
- Shanghai NewMed Medical Corporation, Shanghai, China
| | - Chenyu Jin
- State Key Lab for Strength and Vibration of Mechanical Structures, International Center for Applied Mechanics, Department of Engineering Mechanics, Xi’an Jiaotong University, Xi’an, China
| | - Jian Yang
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China
| | - Zhigang Suo
- John A. Paulson School of Engineering and Applied Sciences, Kavli Institute for Bionano Science and Technology, Harvard University, Cambridge, MA, USA
| | - Jingda Tang
- State Key Lab for Strength and Vibration of Mechanical Structures, International Center for Applied Mechanics, Department of Engineering Mechanics, Xi’an Jiaotong University, Xi’an, China
| |
Collapse
|
9
|
Preliminary In Vitro Assessment of Decellularized Porcine Descending Aorta for Clinical Purposes. J Funct Biomater 2023; 14:jfb14030141. [PMID: 36976065 PMCID: PMC10058365 DOI: 10.3390/jfb14030141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Conduit substitutes are increasingly in demand for cardiovascular and urological applications. In cases of bladder cancer, radical cystectomy is the preferred technique: after removing the bladder, a urinary diversion has to be created using autologous bowel, but several complications are associated with intestinal resection. Thus, alternative urinary substitutes are required to avoid autologous intestinal use, preventing complications and facilitating surgical procedures. In the present paper, we are proposing the exploitation of the decellularized porcine descending aorta as a novel and original conduit substitute. After being decellularized with the use of two alternative detergents (Tergitol and Ecosurf) and sterilized, the porcine descending aorta has been investigated to assess its permeability to detergents through methylene blue dye penetration analysis and to study its composition and structure by means of histomorphometric analyses, including DNA quantification, histology, two-photon microscopy, and hydroxyproline quantification. Biomechanical tests and cytocompatibility assays with human mesenchymal stem cells have been also performed. The results obtained demonstrated that the decellularized porcine descending aorta preserves its major features to be further evaluated as a candidate material for urological applications, even though further studies have to be carried out to demonstrate its suitability for the specific application, by performing in vivo tests in the animal model.
Collapse
|
10
|
Justin AW, Cammarata F, Guy AA, Estevez SR, Burgess S, Davaapil H, Stavropoulou-Tatla A, Ong J, Jacob AG, Saeb-Parsy K, Sinha S, Markaki AE. Densified collagen tubular grafts for human tissue replacement and disease modelling applications. BIOMATERIALS ADVANCES 2023; 145:213245. [PMID: 36549149 DOI: 10.1016/j.bioadv.2022.213245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 12/07/2022] [Accepted: 12/09/2022] [Indexed: 12/23/2022]
Abstract
There is a significant need across multiple indications for an off-the-shelf bioengineered tubular graft which fulfils the mechanical and biological requirements for implantation and function but does not necessarily require cells for manufacture or deployment. Herein, we present a tissue-like tubular construct using a cell-free, materials-based method of manufacture, utilizing densified collagen hydrogel. Our tubular grafts are seamless, mechanically strong, customizable in terms of lumen diameter and wall thickness, and display a uniform fibril density across the wall thickness and along the tube length. While the method enables acellular grafts to be generated rapidly, inexpensively, and to a wide range of specifications, the cell-compatible densification process also enables a high density of cells to be incorporated uniformly into the walls of the tubes, which we show can be maintained under perfusion culture. Additionally, the method enables tubes consisting of distinct cell domains with cellular configurations at the boundaries which may be useful for modelling aortic disease. Further, we demonstrate additional steps which allow for luminal surface patterning. These results highlight the universality of this approach and its potential for developing the next generation of bioengineered grafts.
Collapse
Affiliation(s)
- Alexander W Justin
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK.
| | - Federico Cammarata
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
| | - Andrew A Guy
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
| | - Silas R Estevez
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
| | - Sebastian Burgess
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
| | - Hongorzul Davaapil
- Wellcome-Medical Research Council Cambridge Stem Cell Institute, Jeffrey Cheah Biomedical Centre, University of Cambridge, Cambridge CB2 0AW, UK; Department of Medicine, Division of Cardiovascular Medicine, University of Cambridge, Cambridge CB2 0QQ, UK
| | | | - John Ong
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK; East of England Gastroenterology Speciality Training Program, Cambridge, UK
| | - Aishwarya G Jacob
- Wellcome-Medical Research Council Cambridge Stem Cell Institute, Jeffrey Cheah Biomedical Centre, University of Cambridge, Cambridge CB2 0AW, UK; Department of Biochemistry, University of Cambridge, Downing Site, Tennis Court Road, Cambridge CB2 1QW, UK
| | - Kourosh Saeb-Parsy
- Department of Surgery, University of Cambridge, and NIHR Cambridge Biomedical Research Centre, Cambridge CB2 0QQ, UK
| | - Sanjay Sinha
- Department of Medicine, Division of Cardiovascular Medicine, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Athina E Markaki
- Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK.
| |
Collapse
|
11
|
Is location a significant parameter in the layer dependent dissection properties of the aorta? Biomech Model Mechanobiol 2022; 21:1887-1901. [PMID: 36057051 DOI: 10.1007/s10237-022-01627-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Accepted: 08/07/2022] [Indexed: 11/02/2022]
Abstract
Proper characterisation of biological tissue is key to understanding the effect of the biomechanical environment in the physiology and pathology of the cardiovascular system. Aortic dissection in particular is a prevalent and sometimes fatal disease that still lacks a complete comprehension of its progression. Its development and outcome, however, depend on the location in the vessel. Dissection properties of arteries are frequently studied via delamination tests, such as the T-peel test and the mixed-mode peel test. So far, a study that performs both tests throughout different locations of the aorta, as well as dissecting several interfaces, is missing. This makes it difficult to extract conclusions in terms of vessel heterogeneity, as a standardised experimental procedure cannot be assured for different studies in literature. Therefore, both dissection tests have been here performed on healthy porcine aortas, dissecting three interfaces of the vessels, i.e., the intima-media, the media-adventitia and the media within itself, considering different locations of the aorta, the ascending thoracic aorta (ATA), the descending thoracic aorta and the infrarenal abdominal aorta (IAA). Significant differences were found for both, layers and location. In particular, dissection forces in the ATA were the highest and the separation of the intima-media interface required significantly the lowest force. Moreover, dissection in the longitudinal direction of the vessel generally required more force than in the circumferential one. These results emphasise the need to characterise aortic tissue considering the specific location and dissected layer of the vessel.
Collapse
|
12
|
Kefalidi E, Angouras DC, Sokolis DP. Regional and directional variations in the layer-specific resistance to tear propagation in ascending thoracic aortic aneurysms. J Biomech 2022; 138:111133. [DOI: 10.1016/j.jbiomech.2022.111133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/29/2022] [Accepted: 05/04/2022] [Indexed: 10/18/2022]
|
13
|
Ma Z, Bao G, Li J. Multifaceted Design and Emerging Applications of Tissue Adhesives. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2007663. [PMID: 33956371 DOI: 10.1002/adma.202007663] [Citation(s) in RCA: 97] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 12/04/2020] [Indexed: 05/24/2023]
Abstract
Tissue adhesives can form appreciable adhesion with tissues and have found clinical use in a variety of medical settings such as wound closure, surgical sealants, regenerative medicine, and device attachment. The advantages of tissue adhesives include ease of implementation, rapid application, mitigation of tissue damage, and compatibility with minimally invasive procedures. The field of tissue adhesives is rapidly evolving, leading to tissue adhesives with superior mechanical properties and advanced functionality. Such adhesives enable new applications ranging from mobile health to cancer treatment. To provide guidelines for the rational design of tissue adhesives, here, existing strategies for tissue adhesives are synthesized into a multifaceted design, which comprises three design elements: the tissue, the adhesive surface, and the adhesive matrix. The mechanical, chemical, and biological considerations associated with each design element are reviewed. Throughout the report, the limitations of existing tissue adhesives and immediate opportunities for improvement are discussed. The recent progress of tissue adhesives in topical and implantable applications is highlighted, and then future directions toward next-generation tissue adhesives are outlined. The development of tissue adhesives will fuse disciplines and make broad impacts in engineering and medicine.
Collapse
Affiliation(s)
- Zhenwei Ma
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
| | - Guangyu Bao
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
| | - Jianyu Li
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
- Department of Biomedical Engineering, McGill University, Montréal, QC, H3A 2B4, Canada
| |
Collapse
|
14
|
Ban E, Cavinato C, Humphrey JD. Differential propensity of dissection along the aorta. Biomech Model Mechanobiol 2021; 20:895-907. [PMID: 33464476 PMCID: PMC8159901 DOI: 10.1007/s10237-021-01418-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 01/04/2021] [Indexed: 12/13/2022]
Abstract
Aortic dissections progress, in part, by delamination of the wall. Previous experiments on cut-open segments of aorta demonstrated that fluid injected within the wall delaminates the aorta in two distinct modes: stepwise progressive tearing in the abdominal aorta and a more prevalent sudden mode of tearing in the thoracic aorta that can also manifest in other regions. A microstructural understanding that delineates these two modes of tearing has remained wanting. We implemented a phase-field finite-element model of the aortic wall, motivated in part by two-photon imaging, and found correlative relations for the maximum pressure prior to tearing as a function of local geometry and material properties. Specifically, the square of the pressure of tearing relates directly to both tissue stiffness and the critical energy of tearing and inversely to the square root of the torn area; this correlation explains the sudden mode of tearing and, with the microscopy, suggests a mechanism for progressive tearing. Microscopy also confirmed that thick interlamellar radial struts are more abundant in the abdominal region of the aorta, where progressive tearing was observed previously. The computational results suggest that structurally significant radial struts increase tearing pressure by two mechanisms: confining the fluid by acting as barriers to flow and increasing tissue stiffness by holding the adjacent lamellae together. Collectively, these two phase-field models provide new insights into the mechanical factors that can influence intramural delaminations that promote aortic dissection.
Collapse
Affiliation(s)
- Ehsan Ban
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06520, USA.
| | - Cristina Cavinato
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06520, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06520, USA
| |
Collapse
|
15
|
Brunet J, Pierrat B, Badel P. Review of Current Advances in the Mechanical Description and Quantification of Aortic Dissection Mechanisms. IEEE Rev Biomed Eng 2021; 14:240-255. [PMID: 31905148 DOI: 10.1109/rbme.2019.2950140] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aortic dissection is a life-threatening event associated with a very poor outcome. A number of complex phenomena are involved in the initiation and propagation of the disease. Advances in the comprehension of the mechanisms leading to dissection have been made these last decades, thanks to improvements in imaging and experimental techniques. However, the micro-mechanics involved in triggering such rupture events remains poorly described and understood. It constitutes the primary focus of the present review. Towards the goal of detailing the dissection phenomenon, different experimental and modeling methods were used to investigate aortic dissection, and to understand the underlying phenomena involved. In the last ten years, research has tended to focus on the influence of microstructure on initiation and propagation of the dissection, leading to a number of multiscale models being developed. This review brings together all these materials in an attempt to identify main advances and remaining questions.
Collapse
|
16
|
Alania Y, Creighton J, Trevelin LT, Zamperini CA, Bedran-Russo AK. Regional contribution of proteoglycans to the fracture toughness of the dentin extracellular matrix. J Biomech 2020; 101:109633. [PMID: 32035660 DOI: 10.1016/j.jbiomech.2020.109633] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 01/06/2020] [Accepted: 01/12/2020] [Indexed: 12/11/2022]
Abstract
This study investigated the contribution of small leucine rich proteoglycans (SLRPs) to the fracture toughness of the dentin extracellular matrix (ECM) by enzymatically-assisted selective removal of glycosaminoglycan chains (GAGs) and proteoglycans (PGs) core protein. We adapted the Mode III trouser tear test to evaluate the energy required to tear the dentin ECM. Trouser-shaped dentin specimens from crown and root were demineralized. Depletion of GAGs and PGs followed enzymatic digestion using chondroitinase ABC (c-ABC) and matrix metalloproteinase 3 (MMP-3), respectively. The legs from specimen were stretched under tensile force and the load at tear propagation was determined to calculate the tear energy (T, kJ/m2). SLRPs decorin and biglycan were visualized by immunohistochemistry and ECM tear pattern was analyzed in SEM. Results showed T of crown ECM was not affected by PGs/GAGs depletion (p = 0.799), whereas the removal of PGs significantly reduced T in root dentin ECM (p = 0.001). Root dentin ECM exhibited higher T than crown (p < 0.03), however no regional difference are present after PG depletion (p = 0.480). Immunohistochemistry confirmed removal of GAGs and PGs. SEM images showed structural modifications after PGs/GAGs removal such as enlargement of dentinal tubules, increased interfibrillar spaces and presence of untwisted fibrils with increased diameter. Findings indicate that the capacity of the PGs to unfold and untwist contribute to the dentin ECM resistance to tear, possibly influencing crack growth propagation. The regional differences are likely an evolutionary design to increase tooth survival, that undergoes repetitive mechanical loading and load stress dissipation over a lifetime of an individual.
Collapse
Affiliation(s)
- Yvette Alania
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, 801 South Paulina St, Chicago, IL 60612, USA
| | - Johnathon Creighton
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, 801 South Paulina St, Chicago, IL 60612, USA
| | - Livia T Trevelin
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, 801 South Paulina St, Chicago, IL 60612, USA; Department of Restorative Dentistry, School of Dentistry, Municipal University of São Caetano do Sul, Rua Santo Antônio 50, São Caetano do Sul, São Paulo 09521-160, Brazil
| | - Camila A Zamperini
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, 801 South Paulina St, Chicago, IL 60612, USA
| | - Ana K Bedran-Russo
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, 801 South Paulina St, Chicago, IL 60612, USA.
| |
Collapse
|
17
|
Karimi A, Razaghi R, Koyama M. A patient-specific numerical modeling of the spontaneous coronary artery dissection in relation to atherosclerosis. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 182:105060. [PMID: 31514089 DOI: 10.1016/j.cmpb.2019.105060] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 08/28/2019] [Accepted: 08/31/2019] [Indexed: 06/10/2023]
Abstract
The spontaneous coronary artery dissection (SCAD) is a clinical complication of angioplasty leading to an initiation of a tear/crack in the intima layer of the artery. The crack can propagate to the interface of the intima-media layer following by intramural hematoma. The relation between the SCAD and atherosclerosis is a controversial issue, as some studies stated no correlation between them while others showed that a crack can initiate in the intima but cannot propagate into the atrophied media layer. To investigate the relation between the intraluminal crack propagation in the atherosclerotic artery and SCAD, this study numerically investigated the initiation and propagation of a crack in the intraluminal and radial locations of the healthy and atherosclerotic human coronary arterial walls. The energy release rate, namely J-integral, is computed as a numerical derivative of the strain energy with respect to a crack extension using a user-defined virtual crack method (VCE) of extended finite element method (XFEM). Experimental measurements were carried out to calculate the elasto-plastic mechanical properties of the healthy and atherosclerotic human coronary arteries. The experimental data were then assigned to our own established patient-specific FE model of the coronary artery. Cracks were sketched in the intraluminal and radial locations of the arterial wall and allowed to propagate to the virtual interface of the intima-media to form a false lumen. The results revealed a higher stress at the crack tip of the healthy arterial wall compared to the atherosclerotic one. Lower crack tip opening displacement (CTOD) and crack tip opening angle (CTOA) were observed in the intraluminal crack of the atherosclerotic artery. J-integral of the atherosclerotic arterial wall was also found to be higher than the healthy one at the intraluminal crack. The results revealed that although a crack can initiate in the intraluminal of an atherosclerotic artery, it cannot propagate into the media layer due to a relatively higher rate of the strain energy release in the atherosclerotic arterial wall compared to the healthy one.
Collapse
Affiliation(s)
- Alireza Karimi
- Department of Mechanical Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
| | - Reza Razaghi
- Research Department, Heel of Scene Ltd., Fukuoka, Japan
| | - Motomichi Koyama
- Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan.
| |
Collapse
|
18
|
Fortunato RN, Robertson AM, Sang C, Maiti S. Computational modeling reveals the relationship between intrinsic failure properties and uniaxial biomechanical behavior of arterial tissue. Biomech Model Mechanobiol 2019; 18:1791-1807. [PMID: 31165377 PMCID: PMC6825527 DOI: 10.1007/s10237-019-01177-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 05/27/2019] [Indexed: 01/20/2023]
Abstract
Biomechanical failure of the artery wall can lead to rupture, a catastrophic event with a high rate of mortality. Thus, there is a pressing need to understand failure behavior of the arterial wall. Uniaxial testing remains the most common experimental technique to assess tissue failure properties. However, the relationship between intrinsic failure parameters of the tissue and measured uniaxial failure properties is not fully established. Furthermore, the effect of the experimental variables, such as specimen shape and boundary conditions, on the measured failure properties is not well understood. We developed a finite element model capable of recapitulating pre-failure and post-failure uniaxial biomechanical response of the arterial tissue specimen. Intrinsic stiffness, strength and fracture toughness of the vessel wall tissue were used as the input material parameters to the model. Two uniaxial testing protocols were considered: a conventional setup with a rectangular specimen held at the grips by cardboard inserts, and the other used a dogbone specimen with soft foam inserts at the grips. Our computational study indicated negligible differences in the peak stress and post-peak mechanical behavior between these two testing protocols. It was also found that the tissue experienced only modest localized failure until higher levels of applied stretch beyond the peak stress. A robust cohesive model was capable of modeling the post-peak biomechanical response, which was primarily governed by tissue fracture toughness. Our results suggest that the post-peak region, in conjunction with the peak stress, must be considered to evaluate the complete biomechanical failure behavior of the soft tissue.
Collapse
Affiliation(s)
- Ronald N Fortunato
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA
| | - Anne M Robertson
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA
- Department of Bioengineering, University of Pittsburgh, 302 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA
| | - Chao Sang
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA
| | - Spandan Maiti
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA.
- Department of Bioengineering, University of Pittsburgh, 302 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA.
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, 940 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA.
| |
Collapse
|
19
|
Sherifova S, Holzapfel GA. Biomechanics of aortic wall failure with a focus on dissection and aneurysm: A review. Acta Biomater 2019; 99:1-17. [PMID: 31419563 PMCID: PMC6851434 DOI: 10.1016/j.actbio.2019.08.017] [Citation(s) in RCA: 82] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 08/05/2019] [Accepted: 08/08/2019] [Indexed: 12/12/2022]
Abstract
Aortic dissections and aortic aneurysms are fatal events characterized by structural changes to the aortic wall. The maximum diameter criterion, typically used for aneurysm rupture risk estimations, has been challenged by more sophisticated biomechanically motivated models in the past. Although these models are very helpful for the clinicians in decision-making, they do not attempt to capture material failure. Following a short overview of the microstructure of the aorta, we analyze the failure mechanisms involved in the dissection and rupture by considering also traumatic rupture. We continue with a literature review of experimental studies relevant to quantify tissue strength. More specifically, we summarize more extensively uniaxial tensile, bulge inflation and peeling tests, and we also specify trouser, direct tension and in-plane shear tests. Finally we analyze biomechanically motivated models to predict rupture risk. Based on the findings of the reviewed studies and the rather large variations in tissue strength, we propose that an appropriate material failure criterion for aortic tissues should also reflect the microstructure in order to be effective. STATEMENT OF SIGNIFICANCE: Aortic dissections and aortic aneurysms are fatal events characterized by structural changes to the aortic wall. Despite the advances in medical, biomedical and biomechanical research, the mortality rates of aneurysms and dissections remain high. The present review article summarizes experimental studies that quantify the aortic wall strength and it discusses biomechanically motivated models to predict rupture risk. We identified contradictory observations and a large variation within and between data sets, which may be due to biological variations, different sample sizes, differences in experimental protocols, etc. Based on the findings of the reviewed literature and the rather large variations in tissue strength, it is proposed that an appropriate criterion for aortic failure should also reflect the microstructure.
Collapse
Affiliation(s)
- Selda Sherifova
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16/2, 8010 Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16/2, 8010 Graz, Austria; Department of Structural Engineering, Norwegian Institute of Science and Technology (NTNU), 7491 Trondheim, Norway.
| |
Collapse
|
20
|
Angouras DC, Kritharis EP, Sokolis DP. Regional distribution of delamination strength in ascending thoracic aortic aneurysms. J Mech Behav Biomed Mater 2019; 98:58-70. [DOI: 10.1016/j.jmbbm.2019.06.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/24/2019] [Accepted: 06/01/2019] [Indexed: 12/22/2022]
|
21
|
Javid F, Shahmansouri N, Angeles J, Mongrain R. Fatigue exhaustion of the mitral valve tissue. Biomech Model Mechanobiol 2018; 18:89-97. [PMID: 30097813 DOI: 10.1007/s10237-018-1070-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2017] [Accepted: 08/02/2018] [Indexed: 11/24/2022]
Abstract
Sudden failure and rupture of the tissue is a rare but serious short-term complication after the mitral valve surgical repair. Excessive cyclic loading on the suture line of the repair can progressively damage the surrounding tissue and finally cause tissue rupture. Moreover, mechanical over-tension, which occurs in a diseased mitral valve, gradually leads to tissue floppiness, mitral annular dilation, and leaflet rupture. In this work, the rupture mechanics of mitral valve is studied by characterizing the fracture toughness exhaustion of healthy tissue. Results of this study show that fracture toughness of the posterior mitral valve is lower than its anterior counterpart, indicating that posterior tissue is more prone to failure. Moreover, the decrease in fracture toughness by increasing the number of fatigue cycles shows that excessive mechanical loading leads to progressive failure and rupture of mitral valve tissue within a damage accumulative process.
Collapse
Affiliation(s)
- Farhad Javid
- Koch Institute for Cancer Research, Massachusetts Institute of Technology, 500 Main St., Cambridge, MA, 02140, USA.
| | - Nastaran Shahmansouri
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St. W., Montreal, Quebec, H3A 0C3, Canada
| | - Jorge Angeles
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St. W., Montreal, Quebec, H3A 0C3, Canada.,Department of Mechanical Engineering, Centre for Intelligent Machines, McGill University, 3480 University Street, Montreal, Quebec, H3A 2A7, Canada
| | - Rosaire Mongrain
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St. W., Montreal, Quebec, H3A 0C3, Canada
| |
Collapse
|
22
|
Haslach HW, Siddiqui A, Weerasooriya A, Nguyen R, Roshgadol J, Monforte N, McMahon E. Fracture mechanics of shear crack propagation and dissection in the healthy bovine descending aortic media. Acta Biomater 2018; 68:53-66. [PMID: 29292167 DOI: 10.1016/j.actbio.2017.12.027] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Revised: 12/06/2017] [Accepted: 12/19/2017] [Indexed: 11/24/2022]
Abstract
This experimental study adopts a fracture mechanics strategy to investigate the mechanical cause of aortic dissection. Inflation of excised healthy bovine aortic rings with a cut longitudinal notch that extends into the media from the intima suggests that an intimal tear may propagate a nearly circumferential-longitudinal rupture surface that is similar to the delamination that occurs in aortic dissection. Radial and 45°-from-radial cut notch orientations, as seen in the thickness surface, produce similar circumferential crack propagation morphologies. Partial cut notches, whose longitudinal length is half the width of the ring, measure the influence of longitudinal material on crack propagation. Such specimens also produce circumferential cracks from the notch root that are visible in the thickness circumferential-radial plane, and often propagate a secondary crack from the base of the notch, visible in the intimal circumferential-longitudinal plane. Inflation of rings with pairs of cut notches demonstrates that a second notch modifies the propagation created in a specimen with a single notch. The circumferential crack propagation is likely a consequence of the laminar medial structure. These fracture surfaces are probably due to non-uniform circumferential shear deformation in the heterogeneous media as the aortic wall expands. The qualitative deformation morphology around the root of the cut notch during inflation is evidence for such shear deformation. The shear apparently results from relative slip in the circumferential direction of collagen fibers. The slip may produce shear in the longitudinal-circumferential plane between medial layers or in the radial-circumferential plane within a medial lamina in an idealized model. Circumferential crack propagation in the media is then a shear mechanical process that might be facilitated by disease of the tissue. STATEMENT OF SIGNIFICANCE An intimal tear of an apparently healthy aortic wall near the aortic arch is life-threatening because it may lead to full rupture or to wall dissection in which delamination of the medial layer extends around most of the aortic circumference. The mechanical events underlying dissection are not definitively established. This experimental fracture mechanics study provides evidence that shear rupture is the main mechanical process underlying aortic dissection. The commonly performed tensile strength tests of aortic tissue are not clinically useful to predict or describe aortic dissection. One implication of the study is that shear tests might produce more fruitful simple assessments of the aortic wall strength. A clinical implication is that when presented with an intimal tear, those who guide care might recommend steps to reduce the shear load on the aorta.
Collapse
|
23
|
Halfwerk FR, Rouwkema J, Gossen JA, Grandjean JG. Supercritical carbon dioxide decellularised pericardium: Mechanical and structural characterisation for applications in cardio-thoracic surgery. J Mech Behav Biomed Mater 2017; 77:400-407. [PMID: 29020662 DOI: 10.1016/j.jmbbm.2017.10.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 09/11/2017] [Accepted: 10/01/2017] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Many biomaterials are used in cardio-thoracic surgery with good short-term results. However, calcification, dehiscence, and formation of scar tissue are reported. The aim of this research is to characterise decellularised pericardium after supercritical carbon dioxide (scCO2) processing as an alternative biological material for uses in cardio-thoracic surgery. METHODS Porcine and bovine pericardium were decellularised using scCO2. Mechanical properties such as tensile strength, elastic modulus, fracture toughness and suture retention strength were determined. Ultrastructure was visualised using Scanning Electron Microscopy. Water uptake and swelling was experimentally determined. Commercially available glutaraldehyde treated bovine pericardium was used as gold standard for comparison. RESULTS scCO2 decellularised porcine (and bovine pericardium) maintained their tensile strength compared to untreated native pericardium (13.3 ± 2.4MPa vs 14.0 ± 4.1MPa, p = 0.73). Tensile strength of glutaraldehyde treated pericardium was significantly higher compared to untreated pericardium (19.4 ± 7.3MPa vs 10.2 ± 2.2MPa, p = 0.02). Suture retention strength of scCO2 treated pericardium was significantly higher than glutaraldehyde treated pericardium (p = 0.01). We found no anisotropy of scCO2 or glutaraldehyde treated pericardium based on a trouser tear test. Ultrastructure was uncompromised in scCO2 treated pericardium, while glutaraldehyde treated pericardium showed deterioration of extracellular matrix. CONCLUSION scCO2 processing preserves initial mechanical and structural properties of porcine and bovine pericardium, while glutaraldehyde processing damages the extracellular matrix of bovine pericardium. Decellularisation of tissue using scCO2 might give long-term solutions for cardio-thoracic surgery without compromising initial good mechanical properties.
Collapse
Affiliation(s)
- Frank R Halfwerk
- Department of Cardio-Thoracic Surgery, Thoraxcentrum Twente, Medisch Spectrum Twente Hospital, PO Box 50000, 7500 KA Enschede, The Netherlands; Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands.
| | - Jeroen Rouwkema
- Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands
| | - Jan A Gossen
- European Medical Contract Manufacturing, 6545 CH Nijmegen, The Netherlands
| | - Jan G Grandjean
- Department of Cardio-Thoracic Surgery, Thoraxcentrum Twente, Medisch Spectrum Twente Hospital, PO Box 50000, 7500 KA Enschede, The Netherlands; Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands
| |
Collapse
|
24
|
Tonsomboon K, Butcher AL, Oyen ML. Strong and tough nanofibrous hydrogel composites based on biomimetic principles. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 72:220-227. [DOI: 10.1016/j.msec.2016.11.025] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 10/13/2016] [Accepted: 11/07/2016] [Indexed: 10/20/2022]
|
25
|
Kermani G, Hemmasizadeh A, Assari S, Autieri M, Darvish K. Investigation of inhomogeneous and anisotropic material behavior of porcine thoracic aorta using nano-indentation tests. J Mech Behav Biomed Mater 2016; 69:50-56. [PMID: 28040607 DOI: 10.1016/j.jmbbm.2016.12.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 12/19/2016] [Accepted: 12/23/2016] [Indexed: 10/20/2022]
Abstract
This study investigates the inhomogeneity and anisotropy of porcine descending thoracic aorta in three dimensions using a custom-made nano-indentation technique and a quasi-linear viscoelastic modeling approach. The indentation tests were conducted in axial, circumferential, and radial orientations with about 100 μm spatial resolution. The ratio of the elastic moduli obtained in different orientations was used to quantify the tissue local anisotropy. The distal sections were generally stiffer than the proximal ones in both axial and circumferential indentations. Four distinct layers were identified across the thickness with significantly different mechanical properties. The stiffness of the medial quadrant was significantly lower than all other quadrants in axial indentation. The anisotropic behavior of the tissue was more pronounced in the lateral quadrant of the distal sections. The results of this study can be used to better understand the mechanisms of aorta deformation and improve the spatial accuracy of computational models of aorta.
Collapse
Affiliation(s)
- Golriz Kermani
- Department of Mechanical Engineering, College of Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, United States
| | - Ali Hemmasizadeh
- Department of Mechanical Engineering, College of Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, United States
| | - Soroush Assari
- Department of Mechanical Engineering, College of Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, United States
| | - Michael Autieri
- Department of Physiology, School of Medicine, Temple University, 3500 N. Broad Street, Philadelphia, PA 19140, United States
| | - Kurosh Darvish
- Department of Mechanical Engineering, College of Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, United States.
| |
Collapse
|
26
|
Evaluating ascending aortic aneurysm tissue toughness: Dependence on collagen and elastin contents. J Mech Behav Biomed Mater 2016; 64:262-71. [DOI: 10.1016/j.jmbbm.2016.08.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 07/16/2016] [Accepted: 08/02/2016] [Indexed: 11/23/2022]
|
27
|
Boyd AJ, Kuhn DC, Lozowy RJ, Kulbisky GP. Low wall shear stress predominates at sites of abdominal aortic aneurysm rupture. J Vasc Surg 2016; 63:1613-9. [DOI: 10.1016/j.jvs.2015.01.040] [Citation(s) in RCA: 94] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Accepted: 01/28/2015] [Indexed: 10/23/2022]
|
28
|
Mascarenhas EJ, Peters MF, Nijs J, Rutten MC, van de Vosse FN, Lopata RG. Assessment of mechanical properties of porcine aortas under physiological loading conditions using vascular elastography. J Mech Behav Biomed Mater 2016; 59:185-196. [DOI: 10.1016/j.jmbbm.2015.12.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Revised: 12/01/2015] [Accepted: 12/10/2015] [Indexed: 01/11/2023]
|
29
|
The influence of composition and location on the toughness of human atherosclerotic femoral plaque tissue. Acta Biomater 2016; 31:264-275. [PMID: 26675125 DOI: 10.1016/j.actbio.2015.11.056] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Revised: 11/18/2015] [Accepted: 11/29/2015] [Indexed: 11/23/2022]
Abstract
The toughness of femoral atherosclerotic tissue is of pivotal importance to understanding the mechanism of luminal expansion during cutting balloon angioplasty (CBA) in the peripheral vessels. Furthermore, the ability to relate this parameter to plaque composition, pathological inclusions and location within the femoral vessels would allow for the improvement of existing CBA technology and for the stratification of patient treatment based on the predicted fracture response of the plaque tissue to CBA. Such information may lead to a reduction in clinically observed complications, an improvement in trial results and an increased adoption of the CBA technique to reduce vessel trauma and further endovascular treatment uptake. This study characterises the toughness of atherosclerotic plaque extracted from the femoral arteries of ten patients using a lubricated guillotine cutting test to determine the critical energy release rate. This information is related to the location that the plaque section was removed from within the femoral vessels and the composition of the plaque tissue, determined using Fourier Transform InfraRed spectroscopy, to establish the influence of location and composition on the toughness of the plaque tissue. Scanning electron microscopy (SEM) is employed to examine the fracture surfaces of the sections to determine the contribution of tissue morphology to toughness. Toughness results exhibit large inter and intra patient and location variance with values ranging far above and below the toughness of healthy porcine arterial tissue (Range: 1330-3035 for location and 140-4560J/m(2) for patients). No significant difference in mean toughness is observed between patients or location. However, the composition parameter representing the calcified tissue content of the plaque correlates significantly with sample toughness (r=0.949, p<0.001). SEM reveals the presence of large calcified regions in the toughest sections that are absent from the least tough sections. Regression analysis highlights the potential of employing the calcified tissue content of the plaque as a preoperative tool for predicting the fracture response of a target lesion to CBA (R(2)=0.885, p<0.001). STATEMENT OF SIGNIFICANCE This study addresses a gap in current knowledge regarding the influence of plaque location, composition and morphology on the toughness of human femoral plaque tissue. Such information is of great importance to the continued improvement of endovascular treatments, particularly cutting balloon angioplasty (CBA), which require experimentally derived data as a framework for assessing clinical cases and advancing medical devices. This study identifies that femoral plaque tissue exhibits large inter and intra patient and location variance regarding tissue toughness. Increasing calcified plaque content is demonstrated to correlate significantly with increasing toughness. This highlights the potential for predicting target lesion toughness which may lead to an increased adoption of the CBA technique and also further the uptake of endovascular treatment.
Collapse
|
30
|
Saey V, Famaey N, Smoljkic M, Claeys E, van Loon G, Ducatelle R, Ploeg M, Delesalle C, Gröne A, Duchateau L, Chiers K. Biomechanical and biochemical properties of the thoracic aorta in warmblood horses, Friesian horses, and Friesians with aortic rupture. BMC Vet Res 2015; 11:285. [PMID: 26581331 PMCID: PMC4652382 DOI: 10.1186/s12917-015-0597-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2015] [Accepted: 11/12/2015] [Indexed: 11/21/2022] Open
Abstract
Background Thoracic aortic rupture and aortopulmonary fistulation are rare conditions in horses. It mainly affects Friesian horses. Intrinsic differences in biomechanical properties of the aortic wall might predispose this breed. The biomechanical and biochemical properties of the thoracic aorta were characterized in warmblood horses, unaffected Friesian horses and Friesians with aortic rupture in an attempt to unravel the underlying pathogenesis of aortic rupture in Friesian horses. Samples of the thoracic aorta at the ligamentum arteriosum (LA), mid thoracic aorta (T1) and distal thoracic aorta (T2) were obtained from Friesian horses with aortic rupture (A), nonaffected Friesian (NA) and warmblood horses (WB). The biomechanical properties of these samples were determined using uniaxial tensile and rupture assays. The percentages of collagen and elastin (mg/mg dry weight) were quantified. Results Data revealed no significant biomechanical nor biochemical differences among the different groups of horses. The distal thoracic aorta displayed an increased stiffness associated with a higher collagen percentage in this area and a higher load-bearing capacity compared to the more proximal segments. Conclusions Our findings match reported findings in other animal species. Study results did not provide evidence that the predisposition of the Friesian horse breed for aortic rupture can be attributed to altered biomechanical properties of the aortic wall. Electronic supplementary material The online version of this article (doi:10.1186/s12917-015-0597-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Veronique Saey
- Laboratory of Veterinary Pathology, Department of Pathology, Bacteriology and Poultry Diseases, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
| | - Nele Famaey
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium.
| | - Marija Smoljkic
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium.
| | - Erik Claeys
- Department of Animal Production, Ghent University, Melle, Belgium.
| | - Gunther van Loon
- Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
| | - Richard Ducatelle
- Laboratory of Veterinary Pathology, Department of Pathology, Bacteriology and Poultry Diseases, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
| | - Margreet Ploeg
- Department of Pathobiology, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
| | - Catherine Delesalle
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands. .,Department of Comparative Physiology and Biometrics, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
| | - Andrea Gröne
- Department of Pathobiology, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
| | - Luc Duchateau
- Department of Comparative Physiology and Biometrics, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
| | - Koen Chiers
- Laboratory of Veterinary Pathology, Department of Pathology, Bacteriology and Poultry Diseases, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
| |
Collapse
|
31
|
Zeinali-Davarani S, Wang Y, Chow MJ, Turcotte R, Zhang Y. Contribution of collagen fiber undulation to regional biomechanical properties along porcine thoracic aorta. J Biomech Eng 2015; 137:051001. [PMID: 25612301 DOI: 10.1115/1.4029637] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Indexed: 01/15/2023]
Abstract
As major extracellular matrix components, elastin, and collagen play crucial roles in regulating the mechanical properties of the aortic wall and, thus, the normal cardiovascular function. The mechanical properties of aorta, known to vary with age and multitude of diseases as well as the proximity to the heart, have been attributed to the variations in the content and architecture of wall constituents. This study is focused on the role of layer-specific collagen undulation in the variation of mechanical properties along the porcine descending thoracic aorta. Planar biaxial tensile tests are performed to characterize the hyperelastic anisotropic mechanical behavior of tissues dissected from four locations along the thoracic aorta. Multiphoton microscopy is used to image the associated regional microstructure. Exponential-based and recruitment-based constitutive models are used to account for the observed mechanical behavior while considering the aortic wall as a composite of two layers with independent properties. An elevated stiffness is observed in distal regions compared to proximal regions of thoracic aorta, consistent with sharper and earlier collagen recruitment estimated for medial and adventitial layers in the models. Multiphoton images further support our prediction that higher stiffness in distal regions is associated with less undulation in collagen fibers. Recruitment-based models further reveal that regardless of the location, collagen in the media is recruited from the onset of stretching, whereas adventitial collagen starts to engage with a delay. A parameter sensitivity analysis is performed to discriminate between the models in terms of the confidence in the estimated model parameters.
Collapse
|
32
|
O’Leary SA, Doyle BJ, McGloughlin TM. The impact of long term freezing on the mechanical properties of porcine aortic tissue. J Mech Behav Biomed Mater 2014; 37:165-73. [DOI: 10.1016/j.jmbbm.2014.04.015] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2014] [Revised: 04/21/2014] [Accepted: 04/27/2014] [Indexed: 11/26/2022]
|
33
|
Lopata RGP, Peters MFJ, Nijs J, Oomens CWJ, Rutten MCM, van de Vosse FN. Vascular elastography: a validation study. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1882-1895. [PMID: 24798385 DOI: 10.1016/j.ultrasmedbio.2014.02.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 01/13/2014] [Accepted: 02/23/2014] [Indexed: 06/03/2023]
Abstract
Vascular elastography techniques are promising tools for mechanical characterization of diseased arteries. These techniques are usually validated with simulations or phantoms or by comparing results with histology or other imaging modalities. In the study described here, vascular elastography was applied to porcine aortas in vitro during inflation testing (n = 10) and results were compared with those of standard bi-axial tensile testing, a technique that directly measures the force applied to the tissue. A neo-Hookean model was fit to the stress-strain data, valid for large deformations. Results indicated good correspondence between the two techniques, with GUS = 110 ± 11 kPa and GTT = 108 ± 10 kPa for ultrasound and tensile testing, respectively. Bland-Altman analysis revealed little bias (GUS-GTT = 2 ± 20 kPa). The next step will be the application of a non-linear material model that is also adaptable for in vivo measurements.
Collapse
Affiliation(s)
- Richard G P Lopata
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - Mathijs F J Peters
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Jan Nijs
- Department of Cardiac Surgery, University Hospital Brussels, Brussels, Belgium
| | - Cees W J Oomens
- Soft Tissue Biomechanics & Engineering, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel C M Rutten
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
34
|
Tonsomboon K, Koh CT, Oyen ML. Time-dependent fracture toughness of cornea. J Mech Behav Biomed Mater 2014; 34:116-23. [PMID: 24566382 DOI: 10.1016/j.jmbbm.2014.01.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Revised: 01/13/2014] [Accepted: 01/21/2014] [Indexed: 10/25/2022]
Abstract
The fracture and time-dependent properties of cornea are very important for the development of corneal scaffolds and prostheses. However, there has been no systematic study of cornea fracture; time-dependent behavior of cornea has never been investigated in a fracture context. In this work, fracture toughness of cornea was characterized by trouser tear tests, and time-dependent properties of cornea were examined by stress-relaxation and uniaxial tensile tests. Control experiments were performed on a photoelastic rubber sheet. Corneal fracture resistance was found to be strain-rate dependent, with values ranging from 3.39±0.57 to 5.40±0.48kJm(-2) over strain rates from 3 to 300mmmin(-1). Results from stress-relaxation tests confirmed that cornea is a nonlinear viscoelastic material. The cornea behaved closer to a viscous fluid at small strain but became relatively more elastic at larger strain. Although cornea properties are greatly dependent on time, the stress-strain responses of cornea were found to be insensitive to the strain rate when subjected to tensile loading.
Collapse
Affiliation(s)
- Khaow Tonsomboon
- Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ, UK
| | - Ching Theng Koh
- Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ, UK
| | - Michelle L Oyen
- Cambridge University Engineering Department, Trumpington Street, Cambridge CB2 1PZ, UK.
| |
Collapse
|
35
|
Forsell C, Swedenborg J, Roy J, Gasser TC. The Quasi-Static Failure Properties of the Abdominal Aortic Aneurysm Wall Estimated by a Mixed Experimental-Numerical Approach. Ann Biomed Eng 2012; 41:1554-66. [DOI: 10.1007/s10439-012-0711-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Accepted: 11/20/2012] [Indexed: 10/27/2022]
|
36
|
Chu B, Gaillard E, Mongrain R, Reiter S, Tardif JC. Characterization of fracture toughness exhaustion in pig aorta. J Mech Behav Biomed Mater 2012; 17:126-36. [PMID: 23122712 DOI: 10.1016/j.jmbbm.2012.08.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2012] [Revised: 08/10/2012] [Accepted: 08/20/2012] [Indexed: 01/05/2023]
Abstract
BACKGROUND Spontaneous rupture of the aorta (SRA) without aneurysm, dissection, inflammation or infection of the aortic wall can be of two types: traumatic and non-traumatic. SRA is most of the time a fatal event. Consequently, it is important to understand the conditions which lead to the aortic rupture, and, in the case of non-traumatic SRA, to predict the temporal likelihood of rupture. METHOD OF APPROACH The present work incorporates the temporal aspect by examining the effects of fatigue on aortic wall properties, and adopts an energy approach, based on fracture toughness, to evaluate the aorta's resistance to rupture. Fracture toughness characterization is a destructive testing process and as a consequence cannot be implemented as a clinical tool. However, using concepts in damage mechanics, in theory, it should be possible to indirectly assess fracture toughness from other mechanical properties, such as aortic wall stiffness. Tissue samples from non-aneurysmal porcine aortas were fatigued and were subjected to both biaxial and guillotine tests to assess wall stiffness variations and fracture toughness exhaustion, respectively. RESULTS The experiments reveal that aortic wall stiffness variations and fracture toughness exhaustion decreased as a function of loading cycles and can be modeled with exponential functions. After one million loading cycles, the stiffness ratio between the non-fatigued sample and the fatigued sample, dropped to about 0.85, while the fracture toughness ratio counterpart fell to about 0.80. CONCLUSION Consequently, the changes in both stiffness and fracture toughness as a function of applied fatigue cycles can be measured in aortic tissues. Moreover, these results suggest the possibility to use fracture toughness exhaustion curves as a fatigue criterion.
Collapse
Affiliation(s)
- Boby Chu
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, QC, Canada H3A 2K6.
| | | | | | | | | |
Collapse
|
37
|
Rouleau L, Tremblay D, Cartier R, Mongrain R, Leask RL. Regional variations in canine descending aortic tissue mechanical properties change with formalin fixation. Cardiovasc Pathol 2012; 21:390-7. [DOI: 10.1016/j.carpath.2011.12.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2010] [Revised: 10/17/2011] [Accepted: 12/15/2011] [Indexed: 11/16/2022] Open
|
38
|
Lillie M, Armstrong T, Gérard S, Shadwick R, Gosline J. Contribution of elastin and collagen to the inflation response of the pig thoracic aorta: Assessing elastin's role in mechanical homeostasis. J Biomech 2012; 45:2133-41. [DOI: 10.1016/j.jbiomech.2012.05.034] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2011] [Revised: 04/05/2012] [Accepted: 05/24/2012] [Indexed: 11/26/2022]
|
39
|
McKenna KA, Hinds MT, Sarao RC, Wu PC, Maslen CL, Glanville RW, Babcock D, Gregory KW. Mechanical property characterization of electrospun recombinant human tropoelastin for vascular graft biomaterials. Acta Biomater 2012; 8:225-33. [PMID: 21846510 DOI: 10.1016/j.actbio.2011.08.001] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Revised: 07/08/2011] [Accepted: 08/01/2011] [Indexed: 12/25/2022]
Abstract
The development of vascular grafts has focused on finding a biomaterial that is non-thrombogenic, minimizes intimal hyperplasia, matches the mechanical properties of native vessels and allows for regeneration of arterial tissue. In this study, the structural and mechanical properties and the vascular cell compatibility of electrospun recombinant human tropoelastin (rTE) were evaluated as a potential vascular graft support matrix. Disuccinimidyl suberate (DSS) was used to cross-link electrospun rTE fibers to produce a polymeric recombinant tropoelastin (prTE) matrix that is stable in aqueous environments. Tubular 1cm diameter prTE samples were constructed for uniaxial tensile testing and 4mm small-diameter prTE tubular scaffolds were produced for burst pressure and cell compatibility evaluations from 15 wt.% rTE solutions. Uniaxial tensile tests demonstrated an average ultimate tensile strength (UTS) of 0.36±0.05 MPa and elastic moduli of 0.15±0.04 and 0.91±0.16 MPa, which were comparable to extracted native elastin. Burst pressures of 485±25 mm Hg were obtained from 4mm internal diameter scaffolds with 453±74 μm average wall thickness. prTE supported endothelial cell growth with typical endothelial cell cobblestone morphology after 48 h in culture. Cross-linked electrospun rTE has promising properties for utilization as a vascular graft biomaterial with customizable dimensions, a compliant matrix and vascular cell compatibility.
Collapse
Affiliation(s)
- Kathryn A McKenna
- Oregon Medical Laser Center, Providence St. Vincent Medical Center, Portland, OR 97225, USA
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Pasta S, Phillippi JA, Gleason TG, Vorp DA. Effect of aneurysm on the mechanical dissection properties of the human ascending thoracic aorta. J Thorac Cardiovasc Surg 2011; 143:460-7. [PMID: 21868041 DOI: 10.1016/j.jtcvs.2011.07.058] [Citation(s) in RCA: 126] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2011] [Revised: 05/25/2011] [Accepted: 07/26/2011] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The acute dissection of an ascending thoracic aortic aneurysm (ATAA) represents a devastating separation of elastic layers occurring when the hemodynamic loads on the diseased wall exceed the adhesive strength between layers. At present, the mechanics underlying aortic dissection are largely unclear, and the biomechanical delamination properties of the aneurysmal aorta are not defined. Individuals with bicuspid aortic valve (BAV) are particularly predisposed to ascending aortic aneurysm formation, with a marked risk of aortic dissection. The purpose of this study was to evaluate and compare the dissection properties of nonaneurysmal and aneurysmal human ascending thoracic aorta from patients with BAV morphology or normal tricuspid aortic valve (TAV) morphology using biomechanical delamination testing. METHODS The influence on the delamination strength (S(d)) of the aorta associated with BAV was compared with that in patients with TAV. After complete delamination of ATAA tissue samples, tensile tests were performed on each delaminated half for comparison of their tensile strengths. RESULTS The results showed that the aneurysmal aortas with BAV and TAV have lower S(d) than nonaneurysmal aortas and that ATAA with BAV has a lower S(d) than that with TAV. We have found a significant difference in S(d) between longitudinal and circumferential directions of the nondiseased aorta, suggesting anisotropic dissection properties. CONCLUSIONS The tensile testing results suggest that the weaker intimal half of the aortic wall might fail before the outer adventitial half. Scanning electron microscope analyses suggest different failure modalities of dissection between the two morphologies, and the lower S(d) in ATAAs appears to be associated with a disorganized microstructure. BAV ATAAs have a lower S(d) than TAV ATAAs, suggesting a greater propensity for aortic dissection.
Collapse
|
41
|
Wang Y, Ning J, Johnson JA, Sutton MA, Lessner SM. Development of a quantitative mechanical test of atherosclerotic plaque stability. J Biomech 2011; 44:2439-45. [PMID: 21757197 DOI: 10.1016/j.jbiomech.2011.06.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2010] [Revised: 06/17/2011] [Accepted: 06/26/2011] [Indexed: 10/17/2022]
Abstract
Atherosclerotic plaque rupture is the main cause of myocardial infarction and stroke. Both clinical and computational studies indicate that the shoulder region, where a plaque joins the vessel wall, is rupture-prone. Previous mechanistic studies focused on mechanical properties of the fibrous cap and tensile stresses, which could lead to tearing of the cap. Based on clinical observations of "mobile floating plaques," we postulate that de-adhesion between the fibrous cap and the underlying vessel wall may also play a role in plaque failure. Thus, measuring adhesive strength of the bond between plaque and vascular wall may provide useful new insights into plaque stability. Delamination experiments, widely used in examining inter-laminar adhesive strength of biological materials, were used to measure adhesive strength of advanced plaques in apolipoprotein E-knockout (apoE-KO) mice after 8 months on Western diet. We measured adhesive strength in terms of local energy release rate, G, during controlled plaque delamination. As a measure of the fracture energy required to delaminate a unit area of plaque from the underlying internal elastic lamina (IEL), G provides a quantitative measure of local adhesive strength of the plaque-IEL interface. The values for G acquired from 16 plaques from nine apoE-KO mouse aortas formed a positively skewed distribution with a mean of 24.5 J/m(2), median of 19.3 J/m(2), first quartile of 10.8 J/m(2), and third quartile of 34.1 J/m(2). These measurements are in the lower range of values reported for soft tissues. Histological studies confirmed delamination occurred at the interface between plaque and IEL.
Collapse
Affiliation(s)
- Ying Wang
- Biomedical Engineering Program, University of South Carolina, Columbia, SC 29209, USA
| | | | | | | | | |
Collapse
|
42
|
Forsell C, Gasser TC. Numerical simulation of the failure of ventricular tissue due to deep penetration: The impact of constitutive properties. J Biomech 2011; 44:45-51. [DOI: 10.1016/j.jbiomech.2010.08.022] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2010] [Revised: 08/13/2010] [Accepted: 08/13/2010] [Indexed: 11/25/2022]
|
43
|
Biomechanics and Pathobiology of Aortic Aneurysms. STUDIES IN MECHANOBIOLOGY, TISSUE ENGINEERING AND BIOMATERIALS 2011. [DOI: 10.1007/8415_2011_84] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
44
|
Gasser TC, Gudmundson P, Dohr G. Failure mechanisms of ventricular tissue due to deep penetration. J Biomech 2009; 42:626-33. [DOI: 10.1016/j.jbiomech.2008.12.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2008] [Revised: 12/09/2008] [Accepted: 12/10/2008] [Indexed: 12/01/2022]
|
45
|
Arterial Tissue in Health and Disease: Experimental Data, Collagen-Based Modeling and Simulation, Including Aortic Dissection. ACTA ACUST UNITED AC 2009. [DOI: 10.1007/978-3-211-95875-9_4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
46
|
Ferrara A, Pandolfi A. Numerical modelling of fracture in human arteries. Comput Methods Biomech Biomed Engin 2008; 11:553-67. [PMID: 19230149 DOI: 10.1080/10255840701771743] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
47
|
Sommer G, Gasser TC, Regitnig P, Auer M, Holzapfel GA. Dissection properties of the human aortic media: an experimental study. J Biomech Eng 2008; 130:021007. [PMID: 18412494 DOI: 10.1115/1.2898733] [Citation(s) in RCA: 112] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Aortic dissection occurs frequently and is clinically challenging; the underlying mechanics remain unclear. The present study investigates the dissection properties of the media of 15 human abdominal aortas (AAs) by means of direct tension tests (n=8) and peeling tests (n=12). The direct tension test demonstrates the strength of the media in the radial direction, while the peeling test allows a steady-state investigation of the dissection propagation. To explore the development of irreversible microscopic changes during medial dissection, histological images (n=8) from four AAs at different peeling stages are prepared and analyzed. Direct tension tests of coin-shaped medial specimens result in a radial failure stress of 140.1+/-15.9 kPa (mean+/-SD, n=8). Peeling tests of rectangular-shaped medial strips along the circumferential and axial directions provide peeling force/width ratios of 22.9+/-2.9 mN/mm (n=5) and 34.8+/-15.5 mN/mm (n=7); the related dissection energies per reference area are 5.1+/-0.6 mJ/cm(2) and 7.6+/-2.7 mJ/cm(2), respectively. Although student's t-tests indicate that force/width values of both experimental tests are not significantly different (alpha=0.05, p=0.125), the strikingly higher resisting force/width obtained for the axial peeling tests is perhaps indicative of anisotropic dissection properties of the human aortic media. Peeling in the axial direction of the aorta generates a remarkably "rougher" dissection surface with respect to the surface generated by peeling in the circumferential direction. Histological analysis of the stressed specimens reveals that tissue damage spreads over approximately six to seven elastic laminae, which is about 15-18% of the thickness of the abdominal aortic media, which forms a pronounced cohesive zone at the dissection front.
Collapse
Affiliation(s)
- Gerhard Sommer
- Institute for Biomechanics, Graz University of Technology, 8010 Graz, Austria
| | | | | | | | | |
Collapse
|
48
|
Humphrey J, Taylor C. Intracranial and abdominal aortic aneurysms: similarities, differences, and need for a new class of computational models. Annu Rev Biomed Eng 2008; 10:221-46. [PMID: 18647115 PMCID: PMC2742216 DOI: 10.1146/annurev.bioeng.10.061807.160439] [Citation(s) in RCA: 187] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Intracranial saccular and abdominal aortic aneurysms (ISAs and AAAs, respectively) result from different underlying disease processes and exhibit different rupture potentials, yet they share many histopathological and biomechanical characteristics. Moreover, as in other vascular diseases, hemodynamics and wall mechanics play important roles in the natural history and possible treatment of these two types of lesions. The goals of this review are twofold: first, to contrast the biology and mechanics of intracranial and abdominal aortic aneurysms to emphasize that separate advances in our understanding of each disease can aid in our understanding of the other disease, and second, to suggest that research on the biomechanics of aneurysms must embrace a new paradigm for analysis. That is, past biomechanical studies have provided tremendous insight but have progressed along separate lines, focusing on either the hemodynamics or the wall mechanics. We submit that there is a pressing need to couple in a new way the separate advances in vascular biology, medical imaging, and computational biofluid and biosolid mechanics to understand better the mechanobiology, pathophysiology, and treatment of these lesions, which continue to be responsible for significant morbidity and mortality. We refer to this needed new class of computational tools as fluid-solid-growth (FSG) models.
Collapse
Affiliation(s)
- J.D. Humphrey
- Department of Biomedical Engineering and M.E. DeBakey Institute Texas A&M University, College Station, TX, USA
| | - C.A. Taylor
- Departments of Bioengineering and Surgery Stanford University, Stanford, CA, USA
| |
Collapse
|
49
|
Abstract
AIM This study assessed segmental changes in the mechanical properties of the aorta at low, physiologic and high stresses, in relation with wall composition and morphometry. METHODS The aorta of 10 healthy pigs was divided into six thoracic and three abdominal segments. Aortic specimens were mechanically tested to failure, i.e. rupture, using a uniaxial tension device. Elastic modulus-stress curves were obtained for low (part I), physiologic (part II) and high (part III) stresses, and submitted to regression analysis; failure parameters were calculated. Histological evaluation was performed using an image-processing system, with quantification of morphometric parameters and composition of the entire vessel and its layers, i.e. media and adventitia. RESULTS Significant differences were found in the regression parameters of parts I, II and III, and in failure parameters, suggesting that the proximal segments were stiffer at low stresses, whereas the distal were less extensible, stronger and stiffer at physiologic and high stresses. Image analysis demonstrated significant differences in morphometry and composition among the different layers and segments of the aorta, with higher elastin content proximally and collagen content distally. Good correlations were found between the regression parameters of parts I and II and elastin content, and between the failure and regression parameters of parts II and III and collagen content. CONCLUSION Segmental changes exist in the structure and mechanical properties of the aorta, depending on the level of aortic pressure. This information is necessary for understanding aortic function at general non-physiologic stress states.
Collapse
Affiliation(s)
- D P Sokolis
- Laboratory of Biomechanics, Foundation of Biomedical Research, Academy of Athens, Athens, Greece.
| |
Collapse
|
50
|
Gasser TC, Holzapfel GA. Modeling Plaque Fissuring and Dissection during Balloon Angioplasty Intervention. Ann Biomed Eng 2007; 35:711-23. [PMID: 17385047 DOI: 10.1007/s10439-007-9258-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2006] [Accepted: 01/09/2007] [Indexed: 10/23/2022]
Abstract
Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.
Collapse
Affiliation(s)
- T Christian Gasser
- Department of Solid Mechanics, School of Engineering Sciences, Royal Institute of Technology (KTH), Osquars Backe 1, SE-100 44, Stockholm, Sweden
| | | |
Collapse
|