1
|
Rabani H, Sheikh-Ahmad M, Sachner R, Yosefia S, Yeiches M, Chen-Konak L, Henig C, Dakwar B, Shalata A, Jovanovic K, Rosenblat I, Laniado M, Matter I, Saiegh L. Using Point of Care Rapid Cortisol Measurement During Adrenal Venous Sampling in Primary Hyperaldosteronism. Diagnostics (Basel) 2024; 14:2692. [PMID: 39682600 DOI: 10.3390/diagnostics14232692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2024] [Revised: 11/25/2024] [Accepted: 11/26/2024] [Indexed: 12/18/2024] Open
Abstract
Objectives: To assess success rates and cost-effectiveness of adrenal venous sampling (AVS) after implementing point-of-care rapid cortisol (RC) testing conducted using a europium nanoparticle-based fluoro-immunoassay in patients with primary hyperaldosteronism. Methods: A retrospective review of AVS procedures was conducted at our medical center between January 2016 and June 2024. The primary objective was to compare the success rates of AVS before and after the implementation of the RC testing. Secondary outcomes included a cost-benefit analysis. Results: Of 55 AVS procedures, 19 were conducted using RC testing and 36 were in the historical control cohort. The success rates for right vein sampling were 79% and 67%, respectively. Overall, in six (31.5%) patients in the RC cohort, a low RC selectivity index (SI) value, calculated within 10 min, enabled determination of unsuccessful cannulation and need for resampling during the same AVS session. Repeated sampling resulted in successful procedures in two cases (10.5%) and unsuccessful AVS in four cases, nonetheless sparing the need for repeated AVS sessions in 31.5% of cases. Utilizing RC potentially spared 6 patients from repeated AVS sessions, and considering the additional expenses on the RC test, its use afforded cost savings of an average of $1288 per patient. Conclusions: We demonstrated the cost-effectiveness of utilizing RC measurement in sparing the need for repeated AVS sessions. RC measurement during AVS enabled identification of correct catheter placement in real time, allowing for prompt decisions regarding the need for additional sampling attempts, thereby reducing subsequent costs of repeated AVS sessions.
Collapse
Affiliation(s)
- Hadas Rabani
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
| | - Mohammad Sheikh-Ahmad
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
- The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Haifa 31096, Israel
| | - Robert Sachner
- Invasive Radiology Unit, Bnai Zion Medical Center, Haifa 31048, Israel
| | - Sawsan Yosefia
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
| | - Michal Yeiches
- Clinical Laboratories Division, Bnai Zion Medical Center, Haifa 31048, Israel
| | - Limor Chen-Konak
- Clinical Laboratories Division, Bnai Zion Medical Center, Haifa 31048, Israel
| | - Clara Henig
- Clinical Laboratories Division, Bnai Zion Medical Center, Haifa 31048, Israel
| | - Balsam Dakwar
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
| | - Anan Shalata
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
| | - Katya Jovanovic
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
| | - Ilana Rosenblat
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
| | - Monica Laniado
- The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Haifa 31096, Israel
- Department of Surgery, Bnai Zion Medical Center, Haifa 31048, Israel
| | - Ibrahim Matter
- The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Haifa 31096, Israel
- Department of Surgery, Bnai Zion Medical Center, Haifa 31048, Israel
| | - Leonard Saiegh
- Endocrinology Unit, Bnai Zion Medical Center, 47 Eliyahu Golomb Boulevard, Haifa 31048, Israel
- The Ruth and Bruce Rappaport Faculty of Medicine, Technion, Haifa 31096, Israel
| |
Collapse
|
2
|
Tang X, Xia W, Han H, Wang Y, Wang B, Gao S, Zhang P. Dual-Fluorescent Quantum Dot Nanobead-Based Lateral Flow Immunoassay for Simultaneous Detection of C-Reactive Protein and Procalcitonin. ACS APPLIED BIO MATERIALS 2024; 7:7659-7665. [PMID: 39482872 DOI: 10.1021/acsabm.4c01230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2024]
Abstract
Simultaneous detection of C-reactive protein (CRP) and procalcitonin (PCT) at the point of care is crucial for the management of infections in patients with inflammation and in critical care settings. The challenge of detecting high concentrations of CRP alongside low concentrations of PCT in plasma from inflammatory patients has limited the clinical application of multiplexed immunoassays. Herein, we developed a lateral flow immunoassay (LFIA) that employs quantum dot nanobeads (QDNBs) of varying sizes and colors to enable the simultaneous quantification of PCT and CRP in human plasma. To extend the dynamic range of CRP detection, we combined QDNBs with smaller particle sizes with the CRP detection antibodies, thereby increasing the assay's dynamic range and reducing the hook effect. At the same time, the stronger fluorescence emitted by these larger QDNBs, in conjugation with the PCT detection antibodies, allows for the detection of PCT at the nanogram level, meeting the demand for high sensitivity. The results show that this method can detect CRP concentrations from 0.1 to 3 mg/L and PCT with a detection limit of 0.09 ng/mL, which is on par with clinically used methods. By employing this dual-color and dual-size QDNB labeling strategy, we successfully achieved simultaneous detection of CRP with a broad dynamic range and PCT with high sensitivity in a one-step point-of-care rapid test.
Collapse
Affiliation(s)
- Xinyue Tang
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
- College of Chemistry and Biological Engineering, Yichun University, Yichun, Jiangxi 336000, China
| | - Wenwen Xia
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
- College of Traditional Chinese Medicine, Yunnan University of Traditional Chinese Medicine, Kunming, Yunnan 650500, China
| | - Huanxing Han
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
| | - Yucheng Wang
- Shanghai Kundao Biotech Inc., Shanghai 201201, China
| | - Bolong Wang
- College of Chemistry and Biological Engineering, Yichun University, Yichun, Jiangxi 336000, China
| | - Shouhong Gao
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
- College of Traditional Chinese Medicine, Yunnan University of Traditional Chinese Medicine, Kunming, Yunnan 650500, China
| | - Pengfei Zhang
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| |
Collapse
|
3
|
Zhang L, Wen S, Khan JU, Liu Y, Maddahfar M, Zhou J, Jin D. Ultrasensitive Rapid Antigen Test by Geometric Lateral Flow Assays and Highly Doped Upconversion Nanoparticles. Anal Chem 2024; 96:16581-16589. [PMID: 39374910 DOI: 10.1021/acs.analchem.4c02379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/09/2024]
Abstract
The paper-based lateral flow assay (LFA) testing strips are currently the most widely used for point-of-care testing (POCT), valued for their rapid result turnaround times in a few minutes. However, their sensitivity has been limited. Upconversion nanoparticles (UCNPs), especially highly doped ones, have emerged as promising luminescent reporters to enhance the LFA sensitivity. These UCNPs exhibit a nonlinear enhancement in luminescence with excitation power density, necessitating higher power densities for higher brightness. In this study, we utilized a geometric paper strip design to minimize the immune reaction area and maximize the excitation power density, enabling ultrasensitive detection of the SARS-CoV-2 nucleoprotein antigen. This design also slowed the antigen flow on the paper strip, extending the reaction time between antigen and antibody, thereby enhancing the efficiency of the immune reaction. Through this design, our approach achieved over a 100-fold enhancement in the limit of detection (LOD) compared with the widely used LFAs, based on gold colloidal nanoparticles and europium nanoparticles. This innovation expands the scope of LFA applications that require a low LOD.
Collapse
Affiliation(s)
- Le Zhang
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Shihui Wen
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Jawairia Umar Khan
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Yuan Liu
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Mahnaz Maddahfar
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Jiajia Zhou
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Dayong Jin
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| |
Collapse
|
4
|
Liu W, Zhang K, Cheng J, Yu S, Cheng C, Jiang B, Zhou L, Li Y. Development and evaluation of a time-resolved fluorescence labelled immunochromatographic strip assay for rapid and quantitative detection of bovine herpesvirus 1. Front Microbiol 2024; 15:1371849. [PMID: 38486701 PMCID: PMC10937450 DOI: 10.3389/fmicb.2024.1371849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 02/19/2024] [Indexed: 03/17/2024] Open
Abstract
Bovine herpes virus 1 (BoHV-1) causes a wide variety of diseases in wild and domestic cattle. The most widely used method for viral identification is real-time PCR, which can only be performed in laboratories using sophisticated instruments by expert personnel. Herein, we developed an ultrasensitive time-resolved fluorescence lateral flow immunochromatographic strip (ICS) assay for detecting BoHV-1 in bovine samples using a monoclonal antibody against BoHV-1 labelled with fluorescent microspheres, which can be applied in any setting. The intact process from sample collection to final result can be achieved in 15 min. The limit of detection of the assay for BoHV-1 was 102 TCID50/100 μL. The coincidence rate of the ICS method and real-time PCR recommended by the World Organization for Animal Health (WOAH) was 100% for negative, 92.30% for positive, and 95.42% for total, as evaluated by the detection of 131 clinical samples. This detection method was specifically targeted to BoHV-1, not exhibiting cross-reactivity with other bovine pathogens including BoHV-5. We developed an ICS assay equipped with a portable instrument that offers a sensitive and specific platform for the rapid and reliable detection of BoHV-1 in the field. The Point-of-Care test of BoHV-1 is suitable for the screening and surveillance of BoHV-1 in dairy herds.
Collapse
Affiliation(s)
- Wenxiao Liu
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
- Research Center for Infectious Diseases in Livestock and Poultry, Beijing Academy of Agricultural and Forestry Sciences, Beijing, China
| | - Kun Zhang
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
- Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Jing Cheng
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
- Research Center for Infectious Diseases in Livestock and Poultry, Beijing Academy of Agricultural and Forestry Sciences, Beijing, China
| | - Shiqiang Yu
- Laboratory of Gastrointestinal Microbiology, Jiangsu Key Laboratory of Gastrointestinal Nutrition and Animal Health, National Center for International Research on Animal Gut Nutrition, College of Animal Science and Technology, Nanjing Agricultural University, Nanjing, Jiangsu, China
| | - Chunjie Cheng
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
| | - Bo Jiang
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
- Research Center for Infectious Diseases in Livestock and Poultry, Beijing Academy of Agricultural and Forestry Sciences, Beijing, China
| | - Linyi Zhou
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
- Research Center for Infectious Diseases in Livestock and Poultry, Beijing Academy of Agricultural and Forestry Sciences, Beijing, China
| | - Yongqing Li
- Institute of Animal Husbandry and Veterinary Medicine, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China
- Research Center for Infectious Diseases in Livestock and Poultry, Beijing Academy of Agricultural and Forestry Sciences, Beijing, China
| |
Collapse
|
5
|
Ma Z, Guo J, Jiang L, Zhao S. Lateral flow immunoassay (LFIA) for dengue diagnosis: Recent progress and prospect. Talanta 2024; 267:125268. [PMID: 37813013 DOI: 10.1016/j.talanta.2023.125268] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 09/22/2023] [Accepted: 10/01/2023] [Indexed: 10/11/2023]
Abstract
Dengue is one of the most widespread and fatal arboviral infections in the world. Early detection of dengue virus (DENV) is essential to prevent the spread of the disease and provide an immediate response. The lateral flow immunoassay (LFIA) systems are low-cost, rapid, sensitive, targeted, and straightforward detection, which is an ideal early detection candidate for point-of-care testing (POCT) in dengue-affected areas. However, current commercial LFIA kits cannot fully satisfy the sensitivity, specificity, serotype differentiation, and multiplex detection requirements. Therefore, various strategies have been applied to optimize the LFIA for DENV detection, including label material improvement, optical enhancement and novel structure design. In this review, we comprehensively presented the snapshot of dengue, the principle of LFIA, and recent progress in the LFIA optimization for dengue diagnoses. Furthermore, this review also discusses insights into the prospect of LFIA dengue diagnostic methods, such as microfluidics, multiplex design, nucleic acid-typed probes and smartphone-assisted result analysis.
Collapse
Affiliation(s)
- Ziting Ma
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, Guangdong, 510006, China
| | - Jinnian Guo
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, Guangdong, 510006, China
| | - Lu Jiang
- Department of Biomedical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, Guangdong, 510006, China.
| | - Suqing Zhao
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, Guangdong, 510006, China.
| |
Collapse
|
6
|
Farka Z, Brandmeier JC, Mickert MJ, Pastucha M, Lacina K, Skládal P, Soukka T, Gorris HH. Nanoparticle-Based Bioaffinity Assays: From the Research Laboratory to the Market. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307653. [PMID: 38039956 DOI: 10.1002/adma.202307653] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 11/16/2023] [Indexed: 12/03/2023]
Abstract
Advances in the development of new biorecognition elements, nanoparticle-based labels as well as instrumentation have inspired the design of new bioaffinity assays. This review critically discusses the potential of nanoparticles to replace current enzymatic or molecular labels in immunoassays and other bioaffinity assays. Successful implementations of nanoparticles in commercial assays and the need for rapid tests incorporating nanoparticles in different roles such as capture support, signal generation elements, and signal amplification systems are highlighted. The limited number of nanoparticles applied in current commercial assays can be explained by challenges associated with the analysis of real samples (e.g., blood, urine, or nasal swabs) that are difficult to resolve, particularly if the same performance can be achieved more easily by conventional labels. Lateral flow assays that are based on the visual detection of the red-colored line formed by colloidal gold are a notable exception, exemplified by SARS-CoV-2 rapid antigen tests that have moved from initial laboratory testing to widespread market adaption in less than two years.
Collapse
Affiliation(s)
- Zdeněk Farka
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Julian C Brandmeier
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstr. 31, 93053, Regensburg, Germany
| | | | - Matěj Pastucha
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
- TestLine Clinical Diagnostics, Křižíkova 188, Brno, 612 00, Czech Republic
| | - Karel Lacina
- CEITEC-Central European Institute of Technology, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Tero Soukka
- Department of Life Technologies/Biotechnology, University of Turku, Kiinamyllynkatu 10, Turku, 20520, Finland
| | - Hans H Gorris
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| |
Collapse
|
7
|
Li Z, Jallow A, Nidiaye S, Huang Y, Zhang Q, Li P, Tang X. Improvement of the sensitivity of lateral flow systems for detecting mycotoxins: Up-to-date strategies and future perspectives. Compr Rev Food Sci Food Saf 2024; 23:e13255. [PMID: 38284606 DOI: 10.1111/1541-4337.13255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/05/2023] [Accepted: 09/30/2023] [Indexed: 01/30/2024]
Abstract
Mycotoxins are dangerous human and animal health-threatening secondary fungal metabolites that can be found in various food and agricultural products. Several countries have established regulations to restrict their presence in food and agricultural products destined for human and animal consumption. Consequently, the need to develop highly sensitive and smart detection systems was recognized worldwide. Lateral flow assay possesses the advantages of easy operation, rapidity, stability, accuracy, and specificity, and it plays an important role in the detection of mycotoxins. Nevertheless, strategies to comprehensively improve the sensitivity of lateral flow assay to mycotoxins in food have rarely been highlighted and discussed. In this article, a comprehensive overview was presented on the application of lateral flow assay in mycotoxin detection in food samples by highlighting the principle of lateral flow assay, presenting a detailed discussion on various analytical performance-improvement strategies, such as the development of high-affinity recognition reagents, immunogen immobilization methods, and signal amplification. Additionally, a detailed discussion on the various signal analyzers and interpretation approaches was provided. Finally, current hurdles and future perspectives on the application of lateral flow assay in the detection of mycotoxins were discussed.
Collapse
Affiliation(s)
- Zhiqiang Li
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
| | - Abdoulie Jallow
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
| | - Seyni Nidiaye
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
| | - Yi Huang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
| | - Qi Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- Food Safety Research Institute, HuBei University, Wuhan, China
- Hubei Hongshan Laboratory, Wuhan, China
| | - Peiwu Li
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- Food Safety Research Institute, HuBei University, Wuhan, China
- Hubei Hongshan Laboratory, Wuhan, China
- Xianghu Laboratory, Hangzhou, China
| | - Xiaoqian Tang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs; Laboratory of Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture and Rural Affairs; Quality Inspection and Test Center for Oil seed Products, Ministry of Agriculture and Rural Affairs; Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- Food Safety Research Institute, HuBei University, Wuhan, China
- Xianghu Laboratory, Hangzhou, China
| |
Collapse
|
8
|
Natarajan S, Priye A. Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification. MICROMACHINES 2023; 14:1993. [PMID: 38004850 PMCID: PMC10673117 DOI: 10.3390/mi14111993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 10/22/2023] [Accepted: 10/24/2023] [Indexed: 11/26/2023]
Abstract
Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA's quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (VR) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method's consistency and reproducibility. The LFA assay's stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study's findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care.
Collapse
Affiliation(s)
- Satheesh Natarajan
- Healthcare Technology Innovation Center, Indian Institute of Technology, Chennai 600113, India;
| | - Aashish Priye
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
- Digital Futures, University of Cincinnati, Cincinnati, OH 45221, USA
| |
Collapse
|
9
|
Jin B, Ma B, Mei Q, Xu S, Deng X, Hong Y, Li J, Xu H, Zhang M. Europium Nanoparticle-Based Lateral Flow Strip Biosensors Combined with Recombinase Polymerase Amplification for Simultaneous Detection of Five Zoonotic Foodborne Pathogens. BIOSENSORS 2023; 13:652. [PMID: 37367017 DOI: 10.3390/bios13060652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 06/01/2023] [Accepted: 06/13/2023] [Indexed: 06/28/2023]
Abstract
The five recognized zoonotic foodborne pathogens, namely, Listeria monocytogenes, Staphylococcus aureus, Streptococcus suis, Salmonella enterica and Escherichia coli O157:H7, pose a major threat to global health and social-economic development. These pathogenic bacteria can cause human and animal diseases through foodborne transmission and environmental contamination. Rapid and sensitive detection for pathogens is particularly important for the effective prevention of zoonotic infections. In this study, rapid and visual europium nanoparticle (EuNP)-based lateral flow strip biosensors (LFSBs) combined with recombinase polymerase amplification (RPA) were developed for the simultaneous quantitative detection of five foodborne pathogenic bacteria. Multiple T lines were designed in a single test strip for increasing the detection throughput. After optimizing the key parameters, the single-tube amplified reaction was completed within 15 min at 37 °C. The fluorescent strip reader recorded the intensity signals from the lateral flow strip and converted the data into a T/C value for quantification measurement. The sensitivity of the quintuple RPA-EuNP-LFSBs reached a level of 101 CFU/mL. It also exhibited good specificity and there was no cross-reaction with 20 non-target pathogens. In artificial contamination experiments, the recovery rate of the quintuple RPA-EuNP-LFSBs was 90.6-101.6%, and the results were consistent with those of the culture method. In summary, the ultrasensitive bacterial LFSBs described in this study have the potential for widespread application in resource-poor areas. The study also provides insights in respect to multiple detection in the field.
Collapse
Affiliation(s)
- Bei Jin
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Biao Ma
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Qing Mei
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Shujuan Xu
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Xin Deng
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Yi Hong
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Jiali Li
- Hangzhou Quickgene Sci-Tech. Co., Ltd., Hangzhou 310018, China
| | - Hanyue Xu
- College of Life Science, China Jiliang University, Hangzhou 310018, China
| | - Mingzhou Zhang
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| |
Collapse
|
10
|
Aira C, Monedero A, Hernández-Antón S, Martínez-Cano J, Camuñas A, Casado N, Nieto R, Gallardo C, García-Durán M, Rueda P, Fresco-Taboada A. Improving African Swine Fever Surveillance Using Fluorescent Rapid Tests. Pathogens 2023; 12:811. [PMID: 37375501 DOI: 10.3390/pathogens12060811] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/02/2023] [Accepted: 06/05/2023] [Indexed: 06/29/2023] Open
Abstract
African swine fever (ASF) is a viral disease of swine with a huge impact due to its high mortality. Lately, the disease has actively spread around the world, affecting new areas from which it had been eradicated long ago. To date, ASF control is carried out by the implementation of strict biosecurity measures such as the early identification of infected animals. In this work, two fluorescent rapid tests were developed to improve the sensitivity of point-of-care diagnosis of ASF. For antigen (Ag) detection in blood, a double-antibody sandwich fluorescent lateral flow assay (LFA) was developed, employing a newly developed recombinant antibody to the VP72 of the virus. To complement the diagnosis, a double-recognition fluorescent LFA was developed using the VP72 for the detection of specific antibodies (Ab) in sera or blood. Both assays statistically improved the detection of the disease when compared to the commercial colorimetric assays INgezim® ASFV CROM Ag and INgezim® PPA CROM Anticuerpo, respectively, with higher statistical significance between 11 and 39 days post-infection. From the observation of results, it can be concluded that the combination of both Ag-LFA and Ab-LFA assays would facilitate the identification of infected animals, regardless of post-infection time.
Collapse
Affiliation(s)
- Cristina Aira
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Alejandro Monedero
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Sonia Hernández-Antón
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Juan Martínez-Cano
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Ana Camuñas
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Nadia Casado
- European Union Reference Laboratory for ASF, Centro de Investigación en Sanidad Animal (CISA-INIA/CSIC), Carretera Algete-El Casar de Talamanca, Km. 8.1, 28130 Madrid, Spain
| | - Raquel Nieto
- European Union Reference Laboratory for ASF, Centro de Investigación en Sanidad Animal (CISA-INIA/CSIC), Carretera Algete-El Casar de Talamanca, Km. 8.1, 28130 Madrid, Spain
| | - Carmina Gallardo
- European Union Reference Laboratory for ASF, Centro de Investigación en Sanidad Animal (CISA-INIA/CSIC), Carretera Algete-El Casar de Talamanca, Km. 8.1, 28130 Madrid, Spain
| | - Marga García-Durán
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Paloma Rueda
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| | - Alba Fresco-Taboada
- Gold Standard Diagnostics Madrid (GSD Madrid), Calle de los Hermanos García Noblejas 39, 28037 Madrid, Spain
| |
Collapse
|
11
|
Tay DMY, Kim S, Hao Y, Yee EH, Jia H, Vleck SM, Chilekwa M, Voldman J, Sikes HD. Accelerating the optimization of vertical flow assay performance guided by a rational systematic model-based approach. Biosens Bioelectron 2023; 222:114977. [PMID: 36516633 DOI: 10.1016/j.bios.2022.114977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 11/29/2022] [Indexed: 12/12/2022]
Abstract
Rapid diagnostic tests (RDTs) have shown to be instrumental in healthcare and disease control. However, they have been plagued by many inefficiencies in the laborious empirical development and optimization process for the attainment of clinically relevant sensitivity. While various studies have sought to model paper-based RDTs, most have relied on continuum-based models that are not necessarily applicable to all operation regimes, and have solely focused on predicting the specific interactions between the antigen and binders. It is also unclear how the model predictions may be utilized for optimizing assay performance. Here, we propose a streamlined and simplified model-based framework, only relying on calibration with a minimal experimental dataset, for the acceleration of assay optimization. We show that our models are capable of recapitulating experimental data across different formats and antigen-binder-matrix combinations. By predicting signals due to both specific and background interactions, our facile approach enables the estimation of several pertinent assay performance metrics such as limit-of-detection, sensitivity, signal-to-noise ratio and difference. We believe that our proposed workflow would be a valuable addition to the toolset of any assay developer, regardless of the amount of resources they have in their arsenal, and aid assay optimization at any stage in their assay development process.
Collapse
Affiliation(s)
- Dousabel M Y Tay
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Microsystems Technology Laboratory, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Seunghyeon Kim
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Yining Hao
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Emma H Yee
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Huan Jia
- Antimicrobial Resistance Integrated Research Group, Singapore-MIT Alliance for Research and Technology, 1 CREATE Way, Singapore, 138602, Singapore
| | - Sydney M Vleck
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Makaya Chilekwa
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Joel Voldman
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Microsystems Technology Laboratory, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Hadley D Sikes
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Antimicrobial Resistance Integrated Research Group, Singapore-MIT Alliance for Research and Technology, 1 CREATE Way, Singapore, 138602, Singapore.
| |
Collapse
|
12
|
Dinga DK, Kasprzycka E, Assunção IP, Winterstein F, Alizade A, Caliskanyürek V, Blödorn D, Winkle J, Kynast U, Lezhnina M. High brightness red emitting polymer beads for immunoassays: Comparison between trifluoroacetylacetonates of Europium. Front Chem 2023; 11:1179247. [PMID: 37153529 PMCID: PMC10157089 DOI: 10.3389/fchem.2023.1179247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 04/04/2023] [Indexed: 05/09/2023] Open
Abstract
Efficiently luminescing spherical polymer particles (beads) in the nanoscale regime of up to approximately 250 nm have become very valuable tools in bioanalytical assays. Eu3+- complexes imbedded in polymethacrylate and polystyrene in particular proved to be extraordinarily useful in sensitive immunochemical and multi-analyte assays, and histo- and cytochemistry. Their obvious advantages derive from both, the possibility to realize very high ratios of emitter complexes to target molecules, and the intrinsically long decay times of the Eu3+-complexes, which allows an almost complete discrimination against bothersome autofluorescence via time-gated measuring techniques; the narrow line emission in conjunction with large apparent Stokes shifts are additional benefits with regard to spectral separation of excitation and emission with optical filters. Last but not least, a reasonable strategy to couple the beads to the analytes is mandatory. We have thus screened a variety of complexes and ancillary ligands; the four most promising candidates evaluated and compared to each other were β-diketonates (trifluoroacetylacetonates, R-CO-CH-CO-CF3, R = - thienyl, -phenyl, -naphthyl and -phenanthryl); highest solubilities in polystyrene were obtained with trioctylphosphine co-ligands. All beads had overall quantum yields in excess of 80% as dried powders and lifetimes well beyond 600 µs. Core-shell particles were devised for the conjugation to model proteins (Avidine, Neutravidine). Their applicability was tested in biotinylated titer plates using time gated measurements and a Lateral Flow Assay as practical examples.
Collapse
Affiliation(s)
- Daniel K. Dinga
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
| | - Ewa Kasprzycka
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
| | - Israel P. Assunção
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
| | - Franziska Winterstein
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
| | - Amina Alizade
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
| | - Volkan Caliskanyürek
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
| | | | | | - Ulrich Kynast
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
- *Correspondence: Marina Lezhnina, ; Ulrich Kynast,
| | - Marina Lezhnina
- Institute for Optical Technologies, Münster University of Applied Sciences, Steinfurt, Germany
- Quantum Analysis GmbH, Münster, Germany
- *Correspondence: Marina Lezhnina, ; Ulrich Kynast,
| |
Collapse
|
13
|
A SERS-based immunochromatographic assay for ultrasensitive and quantitative detection of florfenicol using long wavelength absorption of Au nanocubes. FOOD AGR IMMUNOL 2022. [DOI: 10.1080/09540105.2022.2120852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
14
|
Ince B, Sezgintürk MK. Lateral flow assays for viruses diagnosis: Up-to-date technology and future prospects. Trends Analyt Chem 2022; 157:116725. [PMID: 35815063 PMCID: PMC9252863 DOI: 10.1016/j.trac.2022.116725] [Citation(s) in RCA: 68] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 06/13/2022] [Accepted: 06/23/2022] [Indexed: 11/29/2022]
Abstract
Bacteria, viruses, and parasites are harmful microorganisms that cause infectious diseases. Early detection of diseases is critical to prevent disease transmission and provide epidemic preparedness, as these can cause widespread deaths and public health crises, particularly in resource-limited countries. Lateral flow assay (LFA) systems are simple-to-use, disposable, inexpensive diagnostic devices to test biomarkers in blood and urine samples. Thus, LFA has recently received significant attention, especially during the pandemic. Here, first of all, the design principles and working mechanisms of existing LFA methods are examined. Then, current LFA implementation strategies are presented for communicable disease diagnoses, including COVID-19, zika and dengue, HIV, hepatitis, influenza, malaria, and other pathogens. Furthermore, this review focuses on an overview of current problems and accessible solutions in detecting infectious agents and diseases by LFA, focusing on increasing sensitivity with various detection methods. In addition, future trends in LFA-based diagnostics are envisioned.
Collapse
Affiliation(s)
- Bahar Ince
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey
| |
Collapse
|
15
|
Cai X, Yu J, Song Y. Ultrasensitive lateral flow immunoassay for staphylococcal enterotoxin B using nanosized fluorescent metal-organic frameworks. NANOSCALE 2022; 14:16994-17002. [PMID: 36354367 DOI: 10.1039/d2nr04683k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Owing to their outstanding optical properties and superior physical/chemical stability, dye-doped fluorescent nanoparticles (NPs) are growing exponentially as signal labels of immunochromatographic lateral flow immunoassay (LFA) for the detection of various analytes. However, the key challenge in the design of these fluorescent NPs is to confine the fluorophores inside NPs at extreme concentrations, at which dyes tend to self-quench resulting from the formation of non-fluorescent aggregates. Looking for other advantageous nanomaterials, we propose for the first time the use of a nanosized fluorescent metal-organic framework (nanoMOF) in LFA for the detection of staphylococcal enterotoxin B (SEB) as a model analyte. Featured by the chromophore assembly, the nanoMOF exhibited a high dye loading (∼60%) and strong fluorescence intensity, which was due to the reduced self-quenching of dyes in a variety of MOF matrices. The strong green fluorescence intensity of the nanoMOF gives a high contrast against the background of the strips and the sensitivity reflected by photoluminescence was improved by the enhanced antenna effect. Furthermore, due to the high surface area for antibody stemming, the limit of detection (LOD) of the MOF based LFA for SEB detection was as low as 0.025 ng mL-1. The compatibility of the MOF based LFA with dairy samples and its stability under long-term storage conditions were also demonstrated. The integration of a nanoMOF into LFA to detect toxins could inspire the utilization of such nanomaterial-based labels in similar immunochromatographic testing methods to improve their performance.
Collapse
Affiliation(s)
- Xiaoli Cai
- Department of Nutrition, Hygiene and Toxicology, Academy of Nutrition and Health, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan 430065, China
| | - Jierui Yu
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, Illinois 62901, USA.
| | - Yang Song
- NANOGENE LLC, Gainesville, Florida 32611, USA.
| |
Collapse
|
16
|
Calidonio JM, Gomez-Marquez J, Hamad-Schifferli K. Nanomaterial and interface advances in immunoassay biosensors. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2022; 126:17804-17815. [PMID: 38957865 PMCID: PMC11218816 DOI: 10.1021/acs.jpcc.2c05008] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
Biosensors have been used for a remarkable array of applications, including infectious diseases, environmental monitoring, cancer diagnosis, food safety, and numerous others. In particular, the global COVID-19 pandemic has exposed a need for rapid tests, so the type of biosensor that has gained considerable interest recently are immunoassays, which are used for rapid diagnostics. The performance of paper-based lateral flow and dipstick immunoassays is influenced by the physical properties of the nanoparticles (NPs), NP-antibody conjugates, and paper substrate. Many materials innovations have enhanced diagnostics by increasing sensitivity or enabling unique readouts. However, negative side effects can arise at the interface between the biological sample and biomolecules and the NP or paper substrate, such as non-specific adsorption and protein denaturation. In this Perspective, we discuss the immunoassay components and highlight chemistry and materials innovations that can improve sensitivity. We also explore the range of bio-interface issues that can present challenges for immunoassays.
Collapse
Affiliation(s)
| | | | - Kimberly Hamad-Schifferli
- Department of Engineering, University of Massachusetts Boston, Boston, MA 02125
- School for the Environment, University of Massachusetts Boston, Boston, MA 02125
| |
Collapse
|
17
|
Liu H, Liu Y, Zhou T, Zhou P, Li J, Deng A. Ultrasensitive and Specific Detection of Anticancer Drug 5-Fluorouracil in Blood Samples by a Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunochromatographic Assay. Molecules 2022; 27:4019. [PMID: 35807264 PMCID: PMC9268288 DOI: 10.3390/molecules27134019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 06/18/2022] [Accepted: 06/20/2022] [Indexed: 12/10/2022] Open
Abstract
5-Fluorouracil (5-FU) is an effective anticancer drug widely used in the world. To improve therapy efficiency and reduce side effects, it is very important to frequently detect the concentration of 5-FU in blood samples of patients. In this work, a new type of lateral flow immunochromatographic assay (LFIA) based on surface-enhanced Raman scattering (SERS) for ultrasensitive and specific detection of 5-FU in blood samples was developed. Au@Ag/Au nanoparticles (NPs) employing Au particles as the core and Ag/Au alloy as the shell were synthesized, characterized and used as the substrate in SERS-LFIA due to their high SERS enhancement and biocompatibility. The immunoprobe was made in the form of AuMBA@Ag/Au-Ab in which mercaptobenzoic acid (MBA, a common Raman active reporter) was embedded in the core-shell layer and the monoclonal antibody (mAb) against 5-FU was immobilized on the surface. The performance of SERS-LFIA was similar to that in colloidal gold based-LFIA, and the entire assay time was within 20 min. According to the color intensity on the testing (T) lines of LFIA strips visualized by eyes, the contents of 5-FU in the samples could be qualitatively or semi-quantitatively identified. Furthermore, by measuring the characteristic Raman intensities of MBA on T lines, quantitative detection of 5-FU in the samples were achieved. The IC50 and limit of detection (LOD) of the LFIA for 5-FU were found to be 20.9 pg mL-1 and 4.4 pg mL-1, respectively. There was no cross-reactivity (CR) of the LFIA with nine relative compounds, and the CR with cytosine, tegafur and carmofur were less than 4.5%. The recoveries of 5-FU from spiked blood samples were in the range of 78.6~86.4% with the relative standard deviation (RSD) of 2.69~4.42%. Five blood samples containing 5-FU collected from the Cancer Hospital were measured by SERS-LFIA, and the results were confirmed by LC-MS/MS. It was proven that the proposed method was able to simply and rapidly detect 5-FU in blood samples with high sensitivity, specificity, accuracy and precision.
Collapse
Affiliation(s)
| | | | | | | | - Jianguo Li
- The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Renai Road 199, Suzhou 215123, China; (H.L.); (Y.L.); (T.Z.); (P.Z.)
| | - Anping Deng
- The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Renai Road 199, Suzhou 215123, China; (H.L.); (Y.L.); (T.Z.); (P.Z.)
| |
Collapse
|
18
|
Zhuang H, Xu C, Gao F, Li Y, Lei C, Yu C. Recent Advances in Silica-Nanomaterial-Assisted Lateral Flow Assay. Bioengineering (Basel) 2022; 9:bioengineering9070266. [PMID: 35877318 PMCID: PMC9311751 DOI: 10.3390/bioengineering9070266] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/18/2022] [Accepted: 06/19/2022] [Indexed: 12/20/2022] Open
Abstract
Lateral flow assays (LFAs) have attracted much attention as rapid and affordable point-of-care devices for medical diagnostics. The global SARS-CoV-2 pandemic has further highlighted the importance of LFAs. Many efforts have been made to enhance the sensitivity of LFAs. In recent years, silica nanomaterials have been used to either amplify the signal of label materials or provide stability, resulting in better detection performance. In this review, the recent progress of silica-nanomaterial-assisted LFAs is summarized. The impact of the structure of silica nanomaterials on LFA performance, the challenges and prospects in this research area are also discussed.
Collapse
Affiliation(s)
- Han Zhuang
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
| | - Chun Xu
- School of Dentistry, The University of Queensland, Brisbane, QLD 4006, Australia;
| | - Fang Gao
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
| | - Yiwei Li
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
| | - Chang Lei
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
- Correspondence: (C.L.); (C.Y.)
| | - Chengzhong Yu
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
- Correspondence: (C.L.); (C.Y.)
| |
Collapse
|
19
|
Zhang YY, Li LH, Wang Y, Wang H, Xu ZL, Tian YX, Sun YM, Yang JY, Shen YD. Ultrasensitive and rapid colorimetric detection of paraquat via a high specific VHH nanobody. Biosens Bioelectron 2022; 205:114089. [DOI: 10.1016/j.bios.2022.114089] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 02/03/2022] [Accepted: 02/09/2022] [Indexed: 12/19/2022]
|
20
|
Nano-labeled materials as detection tags for signal amplification in immunochromatographic assay. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116673] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
21
|
Bikkarolla SK, McNamee SE, Vance P, McLaughlin J. High-Sensitive Detection and Quantitative Analysis of Thyroid-Stimulating Hormone Using Gold-Nanoshell-Based Lateral Flow Immunoassay Device. BIOSENSORS 2022; 12:182. [PMID: 35323452 PMCID: PMC8946628 DOI: 10.3390/bios12030182] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 02/22/2022] [Accepted: 03/17/2022] [Indexed: 06/14/2023]
Abstract
Au nanoparticles (AuNPs) have been used as signal reporters in colorimetric lateral flow immunoassays (LFAs) for decades. However, it remains a major challenge to significantly improve the detection sensitivity of traditional LFAs due to the low brightness of AuNPs. As an alternative approach, we overcome this problem by utilizing 150 nm gold nanoshells (AuNSs) that were engineered by coating low-density silica nanoparticles with a thin layer of gold. AuNSs are dark green, have 14 times larger surface area, and are approximately 35 times brighter compared to AuNPs. In this study, we used detection of thyroid-stimulating hormone (TSH) in a proof-of-concept assay. The limit of detection (LOD) with AuNS-based LFA was 0.16 µIU/mL, which is 26 times more sensitive than the conventional colorimetric LFA that utilizes AuNP as a label. The dynamic range of the calibration curve was 0.16−9.5 µIU/mL, making it possible to diagnose both hyperthyroidism (<0.5 µIU/mL) and hypothyroidism (>5 µIU/mL) using AuNS-based LFA. Thus, the developed device has a strong potential for early screening and diagnosis of diseases related to the thyroid hormone.
Collapse
Affiliation(s)
- Santosh Kumar Bikkarolla
- School of Engineering, Engineering Research Institute, University of Ulster, Newtownabbey BT37 0QB, UK;
| | - Sara E. McNamee
- School of Engineering, Engineering Research Institute, University of Ulster, Newtownabbey BT37 0QB, UK;
| | - Paul Vance
- Randox Laboratories Ltd., 55 Diamond Road, Crumlin, County Antrim BT29 4QY, UK;
| | - James McLaughlin
- School of Engineering, Engineering Research Institute, University of Ulster, Newtownabbey BT37 0QB, UK;
| |
Collapse
|
22
|
Ji Y, Hu L, Xiong W, Wang Y, Yang F, Shi M, Zhang H, Shao J, Lu C, Fang D, Deng H, Bian Z, Tang G, Liu S, Fan Z, Liu S. Highly sensitive time-resolved fluoroimmunoassay for the quantitative onsite detection of Alternaria longipes in tobacco. J Appl Microbiol 2022; 132:1250-1259. [PMID: 34312955 DOI: 10.1111/jam.15233] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/05/2021] [Accepted: 07/19/2021] [Indexed: 12/20/2022]
Abstract
AIMS Alternaria longipes is a causal agent of brown spot of tobacco, which remains a serious threat to tobacco production. Herein, we established a detection method for A. longipes in tobacco samples based on the principle of time-resolved fluoroimmunoassay, in order to fulfil the requirement of rapid, sensitive and accurate detection in situ. METHODS AND RESULTS A monoclonal antibody against A. longipes was generated, and its purity and titration were assessed using western blot and ELISA. The size of europium (III) nanospheres was measured to confirm successful antibody conjugation. The method described here can detect A. longipes protein lysates as low as 0.78 ng ml-1 , with recovery rates ranging from 85.96% to 99.67% in spiked tobacco. The specificity was also confirmed using a panel of microorganisms. CONCLUSIONS The fluorescent strips allow rapid and sensitive onsite detection of A. longipes in tobacco samples, with high accuracy, specificity, and repeatability. SIGNIFICANCE AND IMPACT OF THE STUDY This novel detection method provides convenience of using crude samples without complex procedures, and therefore allows rapid onsite detection by end users and quick responses towards A. longipes, which is critical for disease control and elimination of phytopathogens.
Collapse
Affiliation(s)
- Yuan Ji
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Liwei Hu
- Zhengzhou Tobacco Research Institute of China National Tobacco Corporation, Zhengzhou, China
| | - Wei Xiong
- Sichuan Tobacco Quality Supervision and Testing Station, Chengdu, China
| | - Ying Wang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Fei Yang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Mowen Shi
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Haiyan Zhang
- Sichuan Tobacco Quality Supervision and Testing Station, Chengdu, China
| | - Jimin Shao
- Sichuan Tobacco Quality Supervision and Testing Station, Chengdu, China
| | - Canhua Lu
- Yunnan Academy of Tobacco Agricultural Sciences of China National Tobacco Corporation, Kunming, China
| | - Dunhuang Fang
- Yunnan Academy of Tobacco Agricultural Sciences of China National Tobacco Corporation, Kunming, China
| | - Huimin Deng
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Zhaoyang Bian
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Gangling Tang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Shili Liu
- Department of Medical Microbiology, School of Basic Medical Science, Shandong University, Jinan, China
| | - Ziyan Fan
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| | - Shanshan Liu
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, China
| |
Collapse
|
23
|
Srinivasan B, Nanus DM, Erickson D, Mehta S. Highly portable quantitative screening test for prostate-specific antigen at point of care. CURRENT RESEARCH IN BIOTECHNOLOGY 2022; 3:288-299. [PMID: 35083431 PMCID: PMC8789004 DOI: 10.1016/j.crbiot.2021.11.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
Prostate cancer (PCa) is the second most diagnosed cancer among men. Targeted PCa screening may decrease PCa-specific mortality. Prostate-specific antigen (PSA) is the most reliable and widely accepted tumor biomarker for screening and monitoring PCa status. However, in many settings, quantification of serum PSA requires access to centralized laboratories. In this study, we describe a proof-of-concept rapid test combined with a highly portable Cube™ reader for quantification of total PSA from a drop of serum within 20 min. We demonstrated the application of gold nanoshells as a label for lateral flow assay with significant increase in the measured colorimetric signal intensity to achieve five times lower detection limit when compared to the traditionally used 40 nm gold nanosphere labels, without a need for any additional signal amplification steps. We first optimized and evaluated the performance of the assay with commercially available total PSA calibrators. For initial validation with commercially available ACCESS Hybritech PSA calibrator, a detection range of 0.5-150 ng/mL was achieved. We compared the performance of our total PSA test with IMMULITE analyzer for quantification of total PSA in archived human serum samples. On preliminary testing with archived serums samples and comparison with IMMULITE total PSA assay, a correlation of 0.95 (p < .0001) was observed. The highly portable quantitative screening test for PSA described in this study has the potential to make PCa screening more accessible where diagnostic labs and automated immunoassay systems are not available, to reduce therapeutic turnaround time, to streamline clinical care, and to direct patient care for both initial screening and for post-treatment monitoring of patients.
Collapse
Affiliation(s)
- Balaji Srinivasan
- Division of Nutritional Sciences, Cornell University, Ithaca, NY 14853, USA.,Institute for Nutritional Sciences, Global Health, and Technology (INSiGHT), Ithaca, NY, USA
| | - David M Nanus
- Division of Hematology and Medical Oncology, Department of Medicine, Weill Cornell Medicine, New York, NY, USA
| | - David Erickson
- Division of Nutritional Sciences, Cornell University, Ithaca, NY 14853, USA.,Institute for Nutritional Sciences, Global Health, and Technology (INSiGHT), Ithaca, NY, USA.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA
| | - Saurabh Mehta
- Division of Nutritional Sciences, Cornell University, Ithaca, NY 14853, USA.,Institute for Nutritional Sciences, Global Health, and Technology (INSiGHT), Ithaca, NY, USA
| |
Collapse
|
24
|
Danthanarayana AN, Brgoch J, Willson RC. Photoluminescent Molecules and Materials as Diagnostic Reporters in Lateral Flow Assays. ACS APPLIED BIO MATERIALS 2022; 5:82-96. [PMID: 35014811 PMCID: PMC9798899 DOI: 10.1021/acsabm.1c01051] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The lateral flow assay (LFA) is a point-of-care diagnostic test commonly available in an over-the-counter format because of its simplicity, speed, low cost, and portability. The reporter particles in these assays are among their most significant components because they perform the diagnostic readout and dictate the test's sensitivity. Today, gold nanoparticles are frequently used as reporters, but recent work focusing on photoluminescent-based reporter technologies has pushed LFAs to better performance. These efforts have focused specifically on reporters made of organic fluorophores, quantum dots, lanthanide chelates, persistent luminescent phosphors, and upconversion phosphors. In most cases, photoluminescent reporters show enhanced sensitivity compared to conventional gold nanoparticle-based assays. Here, we examine the advantages and disadvantages of these different reporters and highlight their potential benefits in LFAs. Our assessment shows that photoluminescent-based LFAs can not only reach lower detection limits than LFAs with traditional reporters, but they also can be capable of quantitative and multiplex analyte detection. As a result, the photoluminescent reporters make LFAs well-suited for medical diagnostics, the food and agricultural industry, and environmental testing.
Collapse
Affiliation(s)
| | - Jakoah Brgoch
- Department of Chemistry, University of Houston, Houston, Texas 77204, United States
| | - Richard C Willson
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, United States
- Department of Biology and Biochemistry, University of Houston, Houston, Texas 77204, United States
| |
Collapse
|
25
|
Yin M, Nie Y, Liu H, Liu L, Tang L, Dong Y, Hu C, Wang H. Development of a europium nanoparticles lateral flow immunoassay for NGAL detection in urine and diagnosis of acute kidney injury. BMC Nephrol 2022; 23:30. [PMID: 35031018 PMCID: PMC8758895 DOI: 10.1186/s12882-021-02493-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 08/02/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND AKI is related to severe adverse outcomes and mortality with Coronavirus Disease 2019 (COVID-19) patients, that early diagnosed and intervened is imperative. Neutrophil gelatinase-associated lipocalin (NGAL) is one of the most promising biomarkers for detection of acute kidney injury (AKI), but current detection methods are inadequacy, so more rapid, convenient and accuracy methods are needed to detect NGAL for early diagnosis of AKI. Herein, we established a rapid, reliable and accuracy lateral flow immunoassay (LFIA) based on europium nanoparticles (EU-NPS) for the detection of NGAL in human urine specimens. METHODS A double-antibody sandwich immunofluorescent assay using europium doped nanoparticles was employed and the NGAL monoclonal antibodies (MAbs) conjugate as labels were generated by optimizing electric fusion parameters. Eighty-three urine samples were used to evaluate the clinical application efficiency of this method. RESULTS The quantitative detection range of NGAL in AKI was 1-3000 ng/mL, and the detection sensitization was 0.36 ng/mL. The coefficient of variation (CV) of intra-assay and inter-assay were 2.57-4.98 % and 4.11-7.83 %, respectively. Meanwhile, the correlation coefficient between europium nanoparticles-based lateral fluorescence immunoassays (EU-NPS-LFIA) and ARCHITECT analyzer was significant (R2 = 0.9829, n = 83, p < 0.01). CONCLUSIONS Thus, a faster and easier operation quantitative assay of NGAL for AKI has been established, which is very important and meaningful to diagnose the early AKI, suggesting that the assay can provide an early warning of final outcome of disease.
Collapse
Affiliation(s)
- Moli Yin
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Yuanwang Nie
- Academy of laboratory, Jilin Medical University, 132013, Jilin, PR China
| | - Hao Liu
- Academy of laboratory, Jilin Medical University, 132013, Jilin, PR China
| | - Lei Liu
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Lu Tang
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Yuan Dong
- Academy of laboratory, Jilin Medical University, 132013, Jilin, PR China
| | - Chuanmin Hu
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China
| | - Huiyan Wang
- Jilin Collaborative Innovation Center for Antibody Engineering, Jilin Medical University, 132013, Jilin, PR China.
| |
Collapse
|
26
|
A monoclonal antibody-based time-resolved fluorescence microsphere lateral flow immunoassay for paclobutrazol detection. Curr Res Food Sci 2022; 5:1395-1402. [PMID: 36110384 PMCID: PMC9468506 DOI: 10.1016/j.crfs.2022.08.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 07/04/2022] [Accepted: 08/22/2022] [Indexed: 11/24/2022] Open
Abstract
Paclobutrazol (PBZ) is a plant growth inhibitor and fungicide, but it is also carcinogenic and teratogenic, and has potential harm to human health. In this study, two PBZ haptens (PBZ-1, PBZ-2) were synthesized and conjugated with carrier proteins to get artificial antigens. A highly specific monoclonal antibody (mAb) against PBZ was prepared. The antibody subtype was IgG1 and the concentration was 11.03 mg/mL. A sensitive and rapid time-resolved fluorescence microsphere lateral flow immunoassay (TRFMs-LFIA) was established based on the mAb. The activated pH, the mAbs diluents, the mAb reacting concentration and the probe amount were optimized. The visual limit of detection (vLOD) and quantitative limit of detection (qLOD) of the TRFMs-LFIA for PBZ were 50 and 1.72 ng/mL respectively, and the 50% inhibiting concentration (IC50) was 9.38 ng/mL. The pretreatment procedures are simple and rapid, and the detection time of TRFMs-LFIA strip is 6 min. Qualitative and quantitative analysis of PBZ could be achieved under a UV light or with a portable fluorescence immunoassay analyzer. The average recovery rates ranged from 96.2% to 111.9% and the corresponding coefficients of variation (CV) were 4.0%–11.2% in spiked wheat and rice samples. Twenty real wheat and rice samples were measured by the TRFMs-LFIA and compared with Ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS). The measured values showed a good accordance. These results indicated that the proposed assay will provide a novel effective strategy for on-site detection of PBZ. A new immunogen was prepared using thyroglobulin as carrier protein coupled with hapten. A high-sensitivity mAb was prepared using a heterologous coating antigen. Based on anti-PBZ mAb, TRAMs-LFIA was developed for the detection of paclobutrazol residue for the first time. The proposed LFIA was rapid, easy to operate and highly accurate.
Collapse
|
27
|
Schmidt C, Borcherding H, Thiele T, Schedler U, Werner F, Rödiger S, Roggenbuck D, Schierack P. Fluorescence-encoded poly(methyl metharcylate) nanoparticles for a lateral flow assay detecting IgM autoantibodies in rheumatoid arthritis. Anal Biochem 2021; 633:114389. [PMID: 34555369 DOI: 10.1016/j.ab.2021.114389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 09/14/2021] [Accepted: 09/20/2021] [Indexed: 01/07/2023]
Abstract
Rheumatoid arthritis (RA) belongs to the most often occurring autoimmune diseases in the world. For serological diagnosis, IgM auto-antibodies directed against the Fc portion of IgG referred to as rheumatoid factor are used as biomarkers. The autoantibody detection is usually done by ELISA. Such assays are reliable but are not suitable for point-of-care testing in contrast to lateral flow assays. Here, we report the development of a lateral flow assay based on carboxylated fluorescence-encoded poly(methyl methacrylate) nanoparticles. Poly(methyl methacrylate) is a non-toxic plastic with an excellent biocompatibility and high optical transparency which promises especially high sensitive fluorescence detection thereby leading to very sensitive assays. We could detect a positive signal in samples with a nephelometric reading down to 0.4 U/mL. By analyzing 30 sera of patients with a RA diagnosis and 34 sera of healthy test subjects we could confirm positive ELISA results in 72% of all cases and negative ELISA results in 97% of all cases.
Collapse
Affiliation(s)
- Carsten Schmidt
- Brandenburg Technical University Cottbus - Senftenberg, Faculty of Natural Sciences, Universitätsplatz 1, D-01968, Senftenberg, Germany
| | | | - Thomas Thiele
- PolyAn GmbH, Schkopauer Ring 6, D-12681 Berlin, Germany
| | - Uwe Schedler
- PolyAn GmbH, Schkopauer Ring 6, D-12681 Berlin, Germany
| | - Franziska Werner
- in.vent Diagnostica GmbH, Neuendorfstraße 17, D-16761, Henningsdorf, Germany
| | - Stefan Rödiger
- Brandenburg Technical University Cottbus - Senftenberg, Faculty of Natural Sciences, Universitätsplatz 1, D-01968, Senftenberg, Germany
| | - Dirk Roggenbuck
- Brandenburg Technical University Cottbus - Senftenberg, Faculty of Natural Sciences, Universitätsplatz 1, D-01968, Senftenberg, Germany; Generic Assays GmbH, Ludwig-Erhard-Ring 3, D-15827, Dahlewitz/Berlin, Germany
| | - Peter Schierack
- Brandenburg Technical University Cottbus - Senftenberg, Faculty of Natural Sciences, Universitätsplatz 1, D-01968, Senftenberg, Germany.
| |
Collapse
|
28
|
Hristov DR, Gomez-Marquez J, Wade D, Hamad-Schifferli K. SARS-CoV-2 and approaches for a testing and diagnostic strategy. J Mater Chem B 2021; 9:8157-8173. [PMID: 34494642 DOI: 10.1039/d1tb00674f] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The COVID-19 pandemic has led to an unprecedented global health challenge, creating sudden, massive demands for diagnostic testing, treatment, therapies, and vaccines. In particular, the development of diagnostic assays for SARS-CoV-2 has been pursued as they are needed for quarantine, disease surveillance, and patient treatment. One of the major lessons the pandemic highlighted was the need for fast, cheap, scalable and reliable diagnostic methods, such as paper-based assays. Furthermore, it has previously been suggested that paper-based tests may be more suitable for settings with lower resource availability and may help alleviate some supply chain challenges which arose during the COVID-19 pandemic. Therefore, we explore how such devices may fit in a comprehensive diagnostic strategy and how some of the challenges to the technology, e.g. low sensitivity, may be addressed. We discuss the properties of the SARS-CoV-2 virus itself, the COVID-19 disease pathway, and the immune response. We then describe the different diagnostic strategies that have been pursued, focusing on molecular strategies for viral genetic material, antigen tests, and serological assays, and innovations for improving the diagnostic sensitivity and capabilities. Finally, we discuss pressing issues for the future, and what needs to be addressed for the ongoing pandemic and future outbreaks.
Collapse
Affiliation(s)
- Delyan R Hristov
- Department of Engineering, University of Massachusetts Boston, Boston, MA, USA.
| | - Jose Gomez-Marquez
- Little Devices Lab, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Djibril Wade
- iLEAD (Innovation in Laboratory Engineered Accelerated Diagnostics), Institut de Recherche en Santé, de Surveillance Epidémiologique et de Formations (IRESSEF), Dakar, Senegal
| | - Kimberly Hamad-Schifferli
- Department of Engineering, University of Massachusetts Boston, Boston, MA, USA. .,School for the Environment, University of Massachusetts Boston, Boston, MA, USA
| |
Collapse
|
29
|
Zhu J, Dou L, Mi J, Bai Y, Liu M, Shen J, Yu W, Zhang S, Yu X, Wang Z. Production of highly sensitive monoclonal antibody and development of lateral flow assays for phallotoxin detection in urine. Anal Bioanal Chem 2021; 413:4979-4987. [PMID: 34240228 DOI: 10.1007/s00216-021-03457-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/18/2021] [Accepted: 06/07/2021] [Indexed: 10/20/2022]
Abstract
Phallotoxins, toxic cyclopeptides found in wild poisonous mushrooms, are predominant causes of fatal food poisoning. For the early and rapid diagnosis mushroom toxin poisoning, a highly sensitive and robust monoclonal antibody (mAb) against phallotoxins was produced for the first time. The half-maximum inhibition concentration (IC50) values of the mAb-based indirect competitive ELISAs for phallacidin (PCD) and phalloidin (PHD) detection were 0.31 ng mL-1 and 0.35 ng mL-1, respectively. In response to the demand for rapid screening of the type of poisoning and accurate determination of the severity of poisoning, colloidal gold nanoparticle (GNP) and time-resolved fluorescent nanosphere (TRFN) based lateral flow assays (LFA) were developed. The GNP-LFA has a visual cut-off value of 3.0 ng mL-1 for phallotoxins in human urine sample. The TRFN-LFA provides a quantitative readout signal with detection limit of 0.1 ng mL-1 in human urine sample. In this study, urine samples without pretreatment were used directly for the LFA strip tests, and both two LFAs were able to accomplish analysis within 10 min. The results demonstrated that LFAs based on the newly produced, highly sensitive, and robust mAb were able to be used for both rapid qualitative screening of the type of poisoning and accurate quantitative determination of the severity of poisoning after accidental ingestion by patients of toxic mushrooms.
Collapse
Affiliation(s)
- Jianyu Zhu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Leina Dou
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Jiafei Mi
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Yuchen Bai
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Minggang Liu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Jianzhong Shen
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Wenbo Yu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Suxia Zhang
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China.
| | - Xuezhi Yu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China.
| | - Zhanhui Wang
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| |
Collapse
|
30
|
Wang L, Wang X, Cheng L, Ding S, Wang G, Choo J, Chen L. SERS-based test strips: Principles, designs and applications. Biosens Bioelectron 2021; 189:113360. [PMID: 34051383 DOI: 10.1016/j.bios.2021.113360] [Citation(s) in RCA: 99] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 05/10/2021] [Accepted: 05/16/2021] [Indexed: 10/21/2022]
Abstract
Test strips represent a class of point-of-care testing (POCT) tools for analysis of a variety of biomarkers towards diagnostics. Conventional test strips offer benefits of simple operation, visualization, and short detection time, along with the drawbacks of relatively low sensitivity and unavailability of quantitative analysis. Recently, the combination of surface-enhanced Raman scattering (SERS) and test strips have evolved to provide a powerful platform capable of ultrasensitive and multiplex detection of extensive analytes of interest. In this review, we focus on the working principles, design strategies and POCT applications of SERS-based test strips. Initially, both lateral and vertical flow test strips are briefly introduced, followed by presentation of various strategies for reforming SERS-based test strips with better detection performance. Applications of SERS-based test strips in diagnosis of disease biomarkers, nucleic acids and toxins are reviewed, with an emphasis on SERS tag design, sensitivity and analytical applicability. Finally, conclusions are made and perspectives on futuristic research directions are given.
Collapse
Affiliation(s)
- Luyang Wang
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Xiaokun Wang
- Shandong Provincial Key Laboratory of Biochemical Engineering, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Lu Cheng
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Shansen Ding
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Guoqing Wang
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China; Laboratory for Marine Drugs and Bioproducts of Qingdao National Laboratory for Marine Science and Technology, Qingdao, 266237, China.
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea.
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China; College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, China.
| |
Collapse
|
31
|
Wu Q, Yao L, Qin P, Xu J, Sun X, Yao B, Ren F, Chen W. Time-resolved fluorescent lateral flow strip for easy and rapid quality control of edible oil. Food Chem 2021; 357:129739. [PMID: 33971536 DOI: 10.1016/j.foodchem.2021.129739] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 03/08/2021] [Accepted: 03/30/2021] [Indexed: 12/26/2022]
Abstract
Gutter oil is strictly prohibited from being reprocessed back to the catering and food industry. Extensive attention has been paid to rapid screening of gutter oil to guarantee the safety of edible oil. Capsaicin, a special component of condiments, has been adopted as the marker of gutter oil. The time-resolved fluorescent microspheres are utilized for labeling of antibody to capsaicin, which are further applied for the construction of fluorescent lateral-flow-strip (LFS). By simple extraction of capsaicin with ethanol (or liquor) from the edible oil, the capsaicin can be rapid determined with the fluorescent LFS in less than 10 min. As low as 20 ng/mL capsaicin can be visually judged and 2.3 ng/mL is achieved as the detection limit by ImageJ analysis. The illegal gutter oil is also well screened with this time-resolved LFS. This method can be a useful candidate for routine quality monitoring of edible oil and a powerful tool for self-inspection at home.
Collapse
Affiliation(s)
- Qian Wu
- School Food and Biological Engineering, Hefei University of Technology, China
| | - Li Yao
- School Food and Biological Engineering, Hefei University of Technology, China
| | - Panzhu Qin
- School Food and Biological Engineering, Hefei University of Technology, China
| | - Jianguo Xu
- School Food and Biological Engineering, Hefei University of Technology, China
| | - Xun Sun
- School Food and Biological Engineering, Hefei University of Technology, China
| | - Bangben Yao
- School Food and Biological Engineering, Hefei University of Technology, China; Anhui Province Institute of Product Quality Supervision & Inspection, Hefei 230051, PR China.
| | - Fei Ren
- Institute of Forensic Science, Public Security Bureau of Taiyuan, Shanxi 030001, PR China
| | - Wei Chen
- School Food and Biological Engineering, Hefei University of Technology, China.
| |
Collapse
|
32
|
Huang L, Su E, Liu Y, He N, Deng Y, Jin L, Chen Z, Li S. A microfluidic device for accurate detection of hs-cTnI. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2020.09.055] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
33
|
Brazaca LC, Dos Santos PL, de Oliveira PR, Rocha DP, Stefano JS, Kalinke C, Abarza Muñoz RA, Bonacin JA, Janegitz BC, Carrilho E. Biosensing strategies for the electrochemical detection of viruses and viral diseases - A review. Anal Chim Acta 2021; 1159:338384. [PMID: 33867035 PMCID: PMC9186435 DOI: 10.1016/j.aca.2021.338384] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 02/06/2023]
Abstract
Viruses are the causing agents for many relevant diseases, including influenza, Ebola, HIV/AIDS, and COVID-19. Its rapid replication and high transmissibility can lead to serious consequences not only to the individual but also to collective health, causing deep economic impacts. In this scenario, diagnosis tools are of significant importance, allowing the rapid, precise, and low-cost testing of a substantial number of individuals. Currently, PCR-based techniques are the gold standard for the diagnosis of viral diseases. Although these allow the diagnosis of different illnesses with high precision, they still present significant drawbacks. Their main disadvantages include long periods for obtaining results and the need for specialized professionals and equipment, requiring the tests to be performed in research centers. In this scenario, biosensors have been presented as promising alternatives for the rapid, precise, low-cost, and on-site diagnosis of viral diseases. This critical review article describes the advancements achieved in the last five years regarding electrochemical biosensors for the diagnosis of viral infections. First, genosensors and aptasensors for the detection of virus and the diagnosis of viral diseases are presented in detail regarding probe immobilization approaches, detection methods (label-free and sandwich), and amplification strategies. Following, immunosensors are highlighted, including many different construction strategies such as label-free, sandwich, competitive, and lateral-flow assays. Then, biosensors for the detection of viral-diseases-related biomarkers are presented and discussed, as well as point of care systems and their advantages when compared to traditional techniques. Last, the difficulties of commercializing electrochemical devices are critically discussed in conjunction with future trends such as lab-on-a-chip and flexible sensors.
Collapse
Affiliation(s)
- Laís Canniatti Brazaca
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil.
| | - Pãmyla Layene Dos Santos
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil
| | - Paulo Roberto de Oliveira
- Departamento de Ciências Naturais, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil
| | - Diego Pessoa Rocha
- Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Jéssica Santos Stefano
- Departamento de Ciências Naturais, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil; Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Cristiane Kalinke
- Instituto de Química, Universidade Estadual de Campinas, Campinas, SP, 13083-859, Brazil
| | - Rodrigo Alejandro Abarza Muñoz
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil; Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Juliano Alves Bonacin
- Instituto de Química, Universidade Estadual de Campinas, Campinas, SP, 13083-859, Brazil
| | - Bruno Campos Janegitz
- Departamento de Ciências Naturais, Matemática e Educação, Universidade Federal de São Carlos, Araras, SP, 13600-970, Brazil.
| | - Emanuel Carrilho
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica-INCTBio, Campinas, SP, 13083-970, Brazil.
| |
Collapse
|
34
|
Saviñon-Flores F, Méndez E, López-Castaños M, Carabarin-Lima A, López-Castaños KA, González-Fuentes MA, Méndez-Albores A. A Review on SERS-Based Detection of Human Virus Infections: Influenza and Coronavirus. BIOSENSORS 2021; 11:66. [PMID: 33670852 PMCID: PMC7997427 DOI: 10.3390/bios11030066] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 02/19/2021] [Accepted: 02/22/2021] [Indexed: 05/05/2023]
Abstract
The diagnosis of respiratory viruses of zoonotic origin (RVsZO) such as influenza and coronaviruses in humans is crucial, because their spread and pandemic threat are the highest. Surface-enhanced Raman spectroscopy (SERS) is an analytical technique with promising impact for the point-of-care diagnosis of viruses. It has been applied to a variety of influenza A virus subtypes, such as the H1N1 and the novel coronavirus SARS-CoV-2. In this work, a review of the strategies used for the detection of RVsZO by SERS is presented. In addition, relevant information about the SERS technique, anthropozoonosis, and RVsZO is provided for a better understanding of the theme. The direct identification is based on trapping the viruses within the interstices of plasmonic nanoparticles and recording the SERS signal from gene fragments or membrane proteins. Quantitative mono- and multiplexed assays have been achieved following an indirect format through a SERS-based sandwich immunoassay. Based on this review, the development of multiplex assays that incorporate the detection of RVsZO together with their specific biomarkers and/or secondary disease biomarkers resulting from the infection progress would be desirable. These configurations could be used as a double confirmation or to evaluate the health condition of the patient.
Collapse
Affiliation(s)
- Fernanda Saviñon-Flores
- Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico; (F.S.-F.); (E.M.); (M.A.G.-F.)
| | - Erika Méndez
- Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico; (F.S.-F.); (E.M.); (M.A.G.-F.)
| | - Mónica López-Castaños
- Facultad de Ciencias Biológicas, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico;
| | - Alejandro Carabarin-Lima
- Centro de Investigaciones en Ciencias Microbiológicas, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico;
| | - Karen A. López-Castaños
- Centro de Química-ICUAP-Posgrado en Ciencias Ambientales, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico;
| | - Miguel A. González-Fuentes
- Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico; (F.S.-F.); (E.M.); (M.A.G.-F.)
| | - Alia Méndez-Albores
- Centro de Química-ICUAP-Posgrado en Ciencias Ambientales, Benemérita Universidad Autónoma de Puebla, 72570 Puebla, Mexico;
| |
Collapse
|
35
|
Kim K, Kashefi-Kheyrabadi L, Joung Y, Kim K, Dang H, Chavan SG, Lee MH, Choo J. Recent advances in sensitive surface-enhanced Raman scattering-based lateral flow assay platforms for point-of-care diagnostics of infectious diseases. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 329:129214. [PMID: 36568647 PMCID: PMC9759493 DOI: 10.1016/j.snb.2020.129214] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 11/03/2020] [Accepted: 11/05/2020] [Indexed: 05/03/2023]
Abstract
This review reports the recent advances in surface-enhanced Raman scattering (SERS)-based lateral flow assay (LFA) platforms for the diagnosis of infectious diseases. As observed through the recent infection outbreaks of COVID-19 worldwide, a timely diagnosis of the disease is critical for preventing the spread of a disease and to ensure epidemic preparedness. In this regard, an innovative point-of-care diagnostic method is essential. Recently, SERS-based assay platforms have received increasing attention in medical communities owing to their high sensitivity and multiplex detection capability. In contrast, LFAs provide a user-friendly and easily accessible sensing platform. Thus, the combination of LFAs with a SERS detection system provides a new diagnostic modality for accurate and rapid diagnoses of infectious diseases. In this context, we briefly discuss the recent application of LFA platforms for the POC diagnosis of SARS-CoV-2. Thereafter, we focus on the recent advances in SERS-based LFA platforms for the early diagnosis of infectious diseases and their applicability for the rapid diagnosis of SARS-CoV-2. Finally, the key issues that need to be addressed to accelerate the clinical translation of SERS-based LFA platforms from the research laboratory to the bedside are discussed.
Collapse
Key Words
- AuNPs, gold nanoparticles
- BA, bacillary angiomatosis
- CRISPR, Clustered Regularly Interspaced Short Palindromic Repeat
- HIV, human immunodeficiency virus
- IFA, indirect immunofluorescence assay
- IgG, immunoglobulin G
- IgM, immunoglobulin M
- In vitro diagnostics (IVD)
- Infectious disease
- KSHV, Kaposi’s sarcoma herpes virus
- LFA, lateral flow assay
- Lateral flow assay (LFA)
- NC, nitrocellulose
- NS1, nonstructural protein 1
- POC, point-of-care
- PRV, pseudorabies virus
- Point-of-care (POC)
- RT-PCR, real-time polymerase chain reaction
- SARS-CoV-2
- SARS-CoV-2, severe acute respiratory syndrome-coronavirus-2
- SEB, staphylococcal enterotoxin
- SERS, surface-enhanced Raman scattering
- Si-AuNPs, silica-encapsulated AuNPs
- Surface-enhanced Raman scattering (SERS)
- crRNAs, CRISPR RNAs
Collapse
Affiliation(s)
- Kihyun Kim
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea
| | | | - Younju Joung
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea
| | - Kyeongnyeon Kim
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea
| | - Hajun Dang
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea
| | - Sachin Ganpat Chavan
- School of Integrative Engineering, Chung-Ang University, Seoul, 06974, South Korea
| | - Min-Ho Lee
- School of Integrative Engineering, Chung-Ang University, Seoul, 06974, South Korea
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea
| |
Collapse
|
36
|
Martiskainen I, Talha SM, Vuorenpää K, Salminen T, Juntunen E, Chattopadhyay S, Kumar D, Vuorinen T, Pettersson K, Khanna N, Batra G. Upconverting nanoparticle reporter-based highly sensitive rapid lateral flow immunoassay for hepatitis B virus surface antigen. Anal Bioanal Chem 2021; 413:967-978. [PMID: 33230700 PMCID: PMC7813740 DOI: 10.1007/s00216-020-03055-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/22/2020] [Accepted: 11/09/2020] [Indexed: 01/22/2023]
Abstract
Detection of hepatitis B Virus surface antigen (HBsAg) is an established method for diagnosing both acute and chronic hepatitis B virus (HBV) infection. In addition to enzyme immunoassays (EIAs), rapid diagnostic tests (RDTs) are available for the detection of HBsAg in resource-poor settings. However, the available RDTs have inadequate sensitivity and therefore are not suitable for diagnosis of patients with low levels of HBsAg and for blood screening. To provide a high-sensitivity RDT, we developed a lateral flow immunoassay (LFIA) for HBsAg utilizing upconverting nanoparticle (UCNP) reporter. The UCNP-LFIA can use whole blood, serum, or plasma and the results can be read in 30 min using a reader device. When compared with a commercial conventional visually read LFIA, the developed UCNP-LFIA had a Limit of Detection (LoD) of 0.1 IU HBsAg/ml in spiked serum, whereas the LoD of the conventional LFIA was 3.2 IU HBsAg/ml. The developed UCNP-LFIA fulfills the WHO criterion for blood screening (LoD ≤ 0.13 IU HBsAg/ml) in terms of LoD. The UCNP-LFIA and conventional LFIA were evaluated with well-characterized sample panels. The UCNP-LFIA detected 20/24 HBsAg-positive samples within the HBsAg Performance Panel and 8/10 samples within the Mixed Titer Performance Panel, whereas the conventional LFIA detected 8/24 and 4/10 samples in these panels, respectively. The performance of the assays was further evaluated with HBsAg-positive (n = 108) and HBsAg-negative (n = 315) patient samples. In comparison with a central laboratory test, UCNP-LFIA showed 95.4% (95% CI: 89.5-98.5%) sensitivity whereas sensitivity of the conventional LFIA was 87.7% (95%CI: 79.9-93.3%).
Collapse
Affiliation(s)
- Iida Martiskainen
- Department of Biotechnology, University of Turku, 20014, Turku, Finland
| | - Sheikh M Talha
- Department of Biotechnology, University of Turku, 20014, Turku, Finland
| | | | - Teppo Salminen
- Department of Biotechnology, University of Turku, 20014, Turku, Finland
| | - Etvi Juntunen
- Department of Biotechnology, University of Turku, 20014, Turku, Finland
| | - Souvick Chattopadhyay
- Translational Health Science and Technology Institute, NCR Biotech Science Cluster, Faridabad, 121001, India
| | - Dinesh Kumar
- Arrow weighing systems Pvt Ltd (unit Designinnova), New Delhi, 110028, India
| | - Tytti Vuorinen
- Department of Virology and Clinical Microbiology, University of Turku, 20520, Turku, Finland
| | - Kim Pettersson
- Department of Biotechnology, University of Turku, 20014, Turku, Finland
| | - Navin Khanna
- International Centre for Genetic Engineering & Biotechnology, New Delhi, 110067, India
| | - Gaurav Batra
- Translational Health Science and Technology Institute, NCR Biotech Science Cluster, Faridabad, 121001, India.
| |
Collapse
|
37
|
Wang Z, Hu S, Bao H, Xing K, Liu J, Xia J, Lai W, Peng J. Immunochromatographic assay based on time-resolved fluorescent nanobeads for the rapid detection of sulfamethazine in egg, honey, and pork. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2021; 101:684-692. [PMID: 32705699 DOI: 10.1002/jsfa.10681] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 04/17/2020] [Accepted: 07/24/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Sulfamethazine (SMZ), a veterinary drug widely used in animal husbandry, is harmful to human health when excess residues are present in food. In this study, a fast, reliable, and sensitive immunochromatographic assay (ICA) was developed on the basis of the competitive format by using time-resolved fluorescent nanobeads (TRFN) as label for the detection of SMZ in egg, honey, and pork samples. RESULTS Under optimized working conditions, this method had limits of detection of 0.016, 0.049, and 0.029 ng mL-1 and corresponding linear ranges of 0.05 to 1.00, 0.05 to 5.00, and 0.05 to 1.00 ng mL-1 in egg, honey, and pork samples, respectively. The recovery experiments showed that the average recoveries ranged from 90.5% to 113.9%, 82.4% to 112.0%, and 79.8% to 93.4% with corresponding coefficients of variation of 4.1% to 11.7%, 7.5% to 11.5%, and 4.8% to 8.7% for egg, honey, and pork samples, respectively. The developed TRFN-ICA was also systematically compared with high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) by analyzing 45 actual samples from egg, honey, and pork. CONCLUSION Overall, the developed TRFN-ICA had high reliability and excellent potential for the ultrasensitive detection of SMZ for food safety monitoring, also providing a universal platform for the on-site detection of other targets. © 2020 Society of Chemical Industry.
Collapse
Affiliation(s)
- Zexiang Wang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, China
| | - Song Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, China
| | - Huanhuan Bao
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, China
| | - Keyu Xing
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, China
| | - Jintao Liu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, China
| | - Jun Xia
- Jiangxi Institute of Veterinary Drug and Feedstuff Control, Nanchang, China
| | - Weihua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, China
| | - Juan Peng
- School of Food Science and Technology, Nanchang University, Nanchang, China
| |
Collapse
|
38
|
Song Y, Cai X, Ostermeyer G, Yu J, Du D, Lin Y. Self-Assembling Allochroic Nanocatalyst for Improving Nanozyme-Based Immunochromatographic Assays. ACS Sens 2021; 6:220-228. [PMID: 33433202 DOI: 10.1021/acssensors.0c02148] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Paper-based rapid diagnostic tests, such as immunochromatographic assays, namely lateral flow immunoassay (LFA), are valuable alternatives for biomarker detection compared to traditional laboratory-based tests, but these assays need further refinement to consolidate their biosensing capabilities. Nanozyme integration into LFA systems may provide a reliable means of improving the analytic sensitivity of LFA tests. Due to the involvement of multiple liquid-handling steps, the quantitative accuracy is compromised, hence hindering the use of untrained personnel point-of-care use. Self-assembling allochroic nanocatalyst (SAN) assemblies satisfy these LFA quality measures by optimizing analyte-antibody reporting performance and by intrinsically catalyzing chromogen activation, thereby reducing the number of liquid handling steps involved during sample analysis. In SANs, the hydrophobic chromogens serve as peroxidase substrates that self-assemble into nanoparticles at high loading fractions. These features demonstrate the potential for SAN-LFAs to be a valuable patient point-of-care (POC) test. Herein, we describe the SAN fabrication process and employ SAN-LFAs to detect cardiac troponin I-troponin C (cTnI-TnC) and myoglobin (Myo) levels present in plasma samples. Using SAN-LFAs, the limits of detection for cTnI-TnC and Myo were 0.012 ng/mL and 0.2 ng/mL respectively. We also demonstrate SAN compatibility with blood samples and stability under long-term storage conditions. The successful utlization of SANs in LFA-based biomarker detection may inspire these nanocatalysts to be integrated into similar immunochromatographic testing methods.
Collapse
Affiliation(s)
- Yang Song
- School of Mechanical and Material Engineering, Washington State University, Pullman, Washington 99164, United States
- Immuno Diagnostics Division and Biomonitoring, Evergreen System Inc., Seattle, Washington 98105, United States
| | - Xiaoli Cai
- School of Mechanical and Material Engineering, Washington State University, Pullman, Washington 99164, United States
- Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry Central China Normal University, Wuhan 430079, PR China
| | - Grayson Ostermeyer
- School of Biological Sciences, Washington State University, Pullman, Washington 99164, United States
| | - Jierui Yu
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, Illinois 62901, United States
| | - Dan Du
- School of Mechanical and Material Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Yuehe Lin
- School of Mechanical and Material Engineering, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
39
|
Double-Antigen Lateral Flow Immunoassay for the Detection of Anti-HIV-1 and -2 Antibodies Using Upconverting Nanoparticle Reporters. SENSORS 2021; 21:s21020330. [PMID: 33418986 PMCID: PMC7825344 DOI: 10.3390/s21020330] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 12/30/2020] [Accepted: 01/01/2021] [Indexed: 11/17/2022]
Abstract
Rapid diagnostic tests (RDTs) are often used for the detection of anti-human immunodeficiency virus (HIV) antibodies in remote locations in low- and middle-income countries (LMIC) with low or limited access to central laboratories. The typical format of an RDT is a lateral flow assay (LFA) with visual interpretation prone to subjectivity. This risk of misinterpretation can be overcome with luminescent upconverting nanoparticle reporters (UCNPs) measured with a miniaturized easy-to-use reader instrument. An LFA with UCNPs for anti-HIV-1/2 antibodies was developed and the assay performance was evaluated extensively with challenging patient sample panels. Sensitivity (n = 145) of the UCNP-LFA was 96.6% (95% CI: 92.1–98.8%) and specificity (n = 309) was 98.7% (95% CI: 96.7–99.7%). Another set of samples (n = 200) was used for a comparison between the UCNP-LFA and a conventional visual RDT. In this comparison, the sensitivities for HIV-1 were 96.4% (95% CI: 89.8–99.3%) and 97.6% (95% CI: 91.6–99.7%), for the UCNP-LFA and conventional RDT, respectively. The specificity was 100% (95% CI: 96.4–100%) for both assays. The developed UCNP-LFA demonstrates the applicability of UCNPs for the detection of anti-HIV antibodies. The signal measurement is done by a reader instrument, which may facilitate automated result interpretation, archiving and transfer of data from de-centralized locations.
Collapse
|
40
|
Huang W, Guo E, Li J, Deng A. Quantitative and ultrasensitive detection of brombuterol by a surface-enhanced Raman scattering (SERS)-based lateral flow immunochromatographic assay (FLIA) using Ag MBA@Au-Ab as an immunoprobe. Analyst 2021; 146:296-304. [PMID: 33146162 DOI: 10.1039/d0an01949f] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Brombuterol is a new emerging β-adrenergic agonist that has been used as an additive in animal feed to enhance the lean meat-to-fat ratio. Due to its potential harm to consumers, it is urgent to develop sensitive, simple and rapid analytical methods to monitor brombuterol residue. In this study, a competitive lateral flow immunochromatographic assay (FLIA) based on surface-enhanced Raman scattering (SERS) was developed for ultrasensitive quantitative determination of brombuterol in swine liver, pork and feed samples. Ag@Au core-shell bimetallic nanoparticles with the highest SERS enhancement were synthesized, characterized and used as the substrate for preparation of the immunoprobe AgMBA@Au-Ab, in which the Raman reporter mercaptobenzoic acid (MBA) was embedded between the core-shell layers and monoclonal antibodies against brombuterol were immobilized on the surfaces of nanoparticles. The presence of brombuterol was identified through a color change on testing lines. In addition, quantitative detection of brombuterol was achieved by measuring the characteristic Raman peak intensity of MBA in the immunoprobes captured by the coating antigen. The IC50 and limit of detection (LOD) of the SERS-based FLIA for brombuterol were 45 pg mL-1 and 0.11 pg mL-1, respectively. The recoveries of brombuterol from spiked samples were in the range of 87.27-100.16% with relative standard deviations of 1.29%-6.99% (n = 3). The proposed SERS-based LFIA was proven to be a feasible method for ultrasensitive and rapid detection of brombuterol and might be a platform for sensitive and rapid detection of a broad range of analytes in clinical, environmental and food analyses.
Collapse
Affiliation(s)
- Wen Huang
- The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai zRoad 199, Suzhou 215123, China.
| | | | | | | |
Collapse
|
41
|
Mondragón M, Desirena H, Moreno‐Ruiz LA, Bello‐Pérez LA. Luminescent Europium Complex‐Grafted Octenyl Succinylated Starch Nanoparticles. STARCH-STARKE 2020. [DOI: 10.1002/star.201900290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Margarita Mondragón
- Centro Interdisciplinario de Investigación para el Desarrollo Integral Regional (CIIDIR)‐Unidad Oaxaca del Instituto Politécnico Nacional Hornos 1003 Sta. Cruz Xoxocotlán 71230 Santa Cruz Xoxocotlán Oaxaca Mexico
| | - Haggeo Desirena
- Centro de Investigaciones en Óptica (CIO) Lomas del Bosque 115 Lomas del Campestre León Guanajuato 37150 Mexico
| | - Luis Alberto Moreno‐Ruiz
- Centro de Nanociencias y Micro y Nanotecnologías (CNMN) del Instituto Politécnico Nacional Av. Luis Enrique Erro s/n Nueva Industrial Vallejo Cd. De México 07738 Mexico
| | - Luis Arturo Bello‐Pérez
- Centro de Desarrollo de Productos Bióticos (CEPROBI) del Instituto Politécnico Nacional Carr. Yautepec‐Jojutla km. 6 Calle CEPROBI No.8 Col. San Isidro Yautepec Morelos 62731 Mexico
| |
Collapse
|
42
|
[Rapid diagnosis of sexually transmitted infections : Joint statement of DSTIG, RKI, and PEI, as well as the reference centers for HIV, HBV, and HCV and consulting laboratories for Chlamydia, gonococci, and Treponema pallidum]. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2020; 63:1271-1286. [PMID: 32930821 DOI: 10.1007/s00103-020-03218-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
In February 2019, the fourth expert meeting on rapid diagnostic tests (RDTs) for sexually transmitted infections (STI) was held at the Robert Koch Institute (RKI) in Berlin. Novel technical developments and new aspects of RDT applications were discussed by representatives from the German STI Society (DSTIG); RKI; the Paul Ehrlich Institute; national reference centers for HIV, HBV, and HCV; and reference laboratories for Chlamydia, gonococci, and Treponema pallidum.As a result of this meeting, we present a revision of the joint statement on STI diagnostics with RDTs from 2017. The Regulation (EU) 2017/746 of the European Parliament and of the Council on in vitro diagnostic medical devices became effective in May 2017 and includes more stringent regulatory requirements for RDTs, mainly concerning conformity of manufacturing processes and performance characteristics of class D in vitro diagnostics (detection of HIV, HBV, HCV, and T. pallidum). Some RDTs for HIV, HCV, and T. pallidum have been evaluated in clinical studies and/or were WHO prequalified and may be used in low-threshold services. Among them are some HIV RDTs available and approved for self-testing. In addition, some HBV RDTs based on detection of HBs antigen (HBsAg) received WHO prequalification. However, false negative results may occur in samples with low HBsAg levels, as for instance in HIV-coinfected patients receiving antiretroviral therapy. For Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG), antigen-based RDTs still do not allow reliable detection of infection. Only PCR-based CT/NG RDTs possess sufficient diagnostic accuracy to be used as point-of-care tests. Rapid PCR tests for NG, however, do not provide any information about antimicrobial resistance.
Collapse
|
43
|
Qian J, He Q, Liu L, Wang M, Wang B, Cui L. Rapid quantification of artemisinin derivatives in antimalarial drugs with dipstick immunoassays. J Pharm Biomed Anal 2020; 191:113605. [PMID: 32961520 DOI: 10.1016/j.jpba.2020.113605] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/29/2020] [Accepted: 08/28/2020] [Indexed: 10/23/2022]
Abstract
Substandard antimalarial drugs will result in unsatisfied therapeutic efficacy and increase the risk of resistance development. The point-of-care, qualitative, or semi-quantitative dipstick immunoassays cannot differentiate the substandard drugs with confidence. A rapid and quantitative analytical method that can be used under field conditions is needed. Here, three lateral flow immunoassays (LFIAs) based on colloidal gold nanobeads (CGN) as labels were developed for quantification of artemether, dihydroartemisinin and artesunate contents in antimalarial drugs with the aid of a portable optical scanner. Also, time-resolved fluorescent nanobeads (TRFN)-LFIA, coupled with a portable fluorescent lateral flow reader, was developed for quantification of artesunate. Commercial antimalarial drugs were used to validate these LFIAs with comparison to the gold standard high-performance liquid chromatography (HPLC) method. The drug contents estimated with these CGN-LFIAs were in the range of 85.5-109.3% of the contents determined by HPLC with a coefficient of variation (CV) of 4.5-13.0%. The TRFN-LFIA results were in the range of 93.7-108.4% of contents determined by HPLC with a CV of 5.2-8.9%. There were no significant differences between the results of CGN-LFIA and TRFN-LIFA (P = 0.5277, t-test). Both types of LFIAs with portable readers may be used for quantitation of active ingredients in antimalarial drugs and for screening substandard antimalarial drugs in resource-limiting settings.
Collapse
Affiliation(s)
- Jingqi Qian
- College of Agriculture and Biotechnology, China Agricultural University, Beijing 100193, China
| | - Qingqing He
- College of Agriculture and Biotechnology, China Agricultural University, Beijing 100193, China
| | - Lulu Liu
- College of Agriculture and Biotechnology, China Agricultural University, Beijing 100193, China
| | - Mian Wang
- College of Food and Bioengineering, Xihua University, Chengdu 610039, China
| | - Baomin Wang
- College of Agriculture and Biotechnology, China Agricultural University, Beijing 100193, China.
| | - Liwang Cui
- Department of Internal Medicine, Morsani College of Medicine, University of South Florida, 3720 Spectrum Boulevard, Suite 304, Tampa FL 33612, USA.
| |
Collapse
|
44
|
Bayoumy S, Hyytiä H, Leivo J, Talha SM, Huhtinen K, Poutanen M, Hynninen J, Perheentupa A, Lamminmäki U, Gidwani K, Pettersson K. Glycovariant-based lateral flow immunoassay to detect ovarian cancer-associated serum CA125. Commun Biol 2020; 3:460. [PMID: 32826955 PMCID: PMC7442799 DOI: 10.1038/s42003-020-01191-x] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 07/24/2020] [Indexed: 01/09/2023] Open
Abstract
Cancer antigen 125 (CA125) is a widely used biomarker in monitoring of epithelial ovarian cancer (EOC). Due to insufficient cancer specificity of CA125, its diagnostic use is severely compromised. Abnormal glycosylation of CA125 is a unique feature of ovarian cancer cells and could improve differential diagnosis of the disease. Here we describe the development of a quantitative lateral flow immunoassay (LFIA) of aberrantly glycosylated CA125 which is widely superior to the conventional CA125 immunoassay (CA125IA). With a 30 min read-out time, the LFIA showed 72% sensitivity, at 98% specificity using diagnostically challenging samples with marginally elevated CA125 (35–200 U/mL), in comparison to 16% sensitivity with the CA125IA. We envision the clinical use of the developed LFIA to be based on the substantially enhanced disease specificity against the many benign conditions confounding the diagnostic evaluation and against other cancers. Sherif Bayoumy et al. report a lateral flow immunoassay (LFIA) to quantify aberrantly glycosylated CA125 to diagnose epithelial ovarian cancer. Their method has a 30-minute read-out time, high sensitivity and specificity, and can distinguish ovarian cancer from benign endometriosis and other cancers.
Collapse
Affiliation(s)
- Sherif Bayoumy
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland
| | - Heidi Hyytiä
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland.,PerkinElmer Finland Oy, Turku, Finland
| | - Janne Leivo
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland
| | - Sheikh M Talha
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland
| | - Kaisa Huhtinen
- Department of Pathology, Institute of Biomedicine, Research Center for Cancer, Infections and Immunity, University of Turku, Turku, Finland
| | - Matti Poutanen
- Institute of Biomedicine, Research Center for Integrative Physiology and Pharmacology and Turku Center for Disease Modeling, University of Turku, Turku, Finland
| | - Johanna Hynninen
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | - Antti Perheentupa
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | - Urpo Lamminmäki
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland
| | - Kamlesh Gidwani
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland
| | - Kim Pettersson
- Department of Biochemistry/Biotechnology, University of Turku, Turku, Finland.
| |
Collapse
|
45
|
Wang Z, Sun Y, Liang D, Zeng Y, He S, Mari GM, Peng T, Jiang H. Highly sensitive chromatographic time-resolved fluoroimmunoassay for rapid onsite detection of streptomycin in milk. J Dairy Sci 2020; 103:8750-8760. [PMID: 32713697 DOI: 10.3168/jds.2020-18393] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 05/06/2020] [Indexed: 11/19/2022]
Abstract
Antibiotic residues are major contaminants in milk because of their use in agriculture and animal husbandry. In particular, streptomycin, an aminoglycoside antibiotic, is a potential risk to consumers because of its ototoxicity, anaphylaxis, and growth inhibition. Herein, monoclonal antibodies for streptomycin were conjugated with europium microspheres to serve as detection probes for the development of a chromatographic time-resolved fluoroimmunoassay to detect streptomycin residues in milk. The method had a low detection limit of 0.58 µg/kg, a linear range of 0.8 to 6.25 μg/kg, and substantial recovery, from 85.6 to 108.3%. It showed slight cross-reactivity with another aminoglycoside analog. Strong correlations between the results of established chromatographic time-resolved fluoroimmunoassay and ultra-performance liquid chromatography-tandem mass spectrometry indicated that the established fluoroimmunoassay is a reliable method for rapid onsite detection of streptomycin in milk and it has great potential in food safety monitoring.
Collapse
Affiliation(s)
- Zile Wang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China
| | - Yuanze Sun
- Shunyi Animal Health Supervision and Administration Bureau, Beijing 101300, People's Republic of China
| | - Demei Liang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China
| | - Yuyang Zeng
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China
| | - Shuang He
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China
| | - Ghulam Mujtaba Mari
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China
| | - Tao Peng
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China
| | - Haiyang Jiang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, 100193 Beijing, People's Republic of China.
| |
Collapse
|
46
|
Qian J, Xing C, Ge Y, Li R, Li A, Yan W. Gold nanostars-enhanced Raman fingerprint strip for rapid detection of trace tetracycline in water samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 232:118146. [PMID: 32086043 DOI: 10.1016/j.saa.2020.118146] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 02/04/2020] [Accepted: 02/09/2020] [Indexed: 05/25/2023]
Abstract
Rapid and accurate detection of antibiotics at trace levels in food represents a great challenge. Tetracycline (TC), as a sort of broad-spectrum antibiotic, has been extensively used in animal infection therapy and animal husbandry as growth promoters. Large amounts of TC residues in animal-derived foods affect food quality and safety, and cause undesirable side effects such as allergic reactions and bacterial antibiotic resistance. Here, a Raman fingerprint strip sensor was reported based on surface-enhanced Raman scattering technology and demonstrated for ultrasensitive detection of TC. In this approach, 4-aminothiophenol (4-ATP) modified gold nanostars (GNSs) were used as a strong Raman reporter, which was coated with anti-TC monoclonal antibody serving as a biorecognition to acquire both visual and Raman signals on the test line. To demonstrate the performance of this strip, TC standard solutions with concentrations ranging from 0.5 to 50 ng/mL was detected, the limit of the detection (LOD) for the Raman signal was 0.04 ng/mL, which was 100 times more sensitive than those of color intensity quantifications. The other analogues, oxytetracycline, and chlortetracycline were detected using this method, making them suitable for the samples with TC analogues screening.
Collapse
Affiliation(s)
- Jing Qian
- National Center of Meat Quality & Safety Control, College of Food Science and Technology, Nanjing Agricultural University, Nanjing 210095, China
| | - Changrui Xing
- College of Food Science and Engineering/Collaborative Innovation Center for Modern Grain Circulation and Safety/Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing 210023, China
| | - Yonghui Ge
- National Center of Meat Quality & Safety Control, College of Food Science and Technology, Nanjing Agricultural University, Nanjing 210095, China
| | - Rui Li
- National Center of Meat Quality & Safety Control, College of Food Science and Technology, Nanjing Agricultural University, Nanjing 210095, China
| | - Aitong Li
- National Center of Meat Quality & Safety Control, College of Food Science and Technology, Nanjing Agricultural University, Nanjing 210095, China
| | - Wenjing Yan
- National Center of Meat Quality & Safety Control, College of Food Science and Technology, Nanjing Agricultural University, Nanjing 210095, China.
| |
Collapse
|
47
|
Eom S, Bae Y, Kim S, Choi H, Park J, Kang S. Development of Recombinant Immunoglobulin G-Binding Luciferase-Based Signal Amplifiers in Immunoassays. Anal Chem 2020; 92:5473-5481. [PMID: 32142265 DOI: 10.1021/acs.analchem.0c00222] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
In general immunoassays, secondary antibodies are covalently linked with enzymes and bind to the Fc region of target-bound primary antibodies to amplify signals of low-abundant target molecules. The antibodies themselves are obtained from large mammals and are further modified with enzymes. In this study, we developed novel recombinant immunoglobulin G (IgG)-binding luciferase-based signal amplifiers (rILSAs) by genetically fusing luciferase (Nluc) with antimouse IgG1 nanobody (MG1Nb) and antibody-binding domain (ABD), individually or together, in a mix-and-match manner. We obtained three different highly pure rILSAs in large quantities using a bacterial overexpression system and one-step purification. Mouse-specific rILSA, MG1Nb-Nluc, and rabbit-specific rILSA, Nluc-ABD, selectively bound to target-molecule-bound mouse IgG1 and rabbit IgG primary antibodies, whereas the bispecific rILSA, MG1Nb-Nluc-ABD, mutually bound to both mouse IgG1 and rabbit IgG primary antibodies. All rILSAs exhibited an outstanding signal-amplifying capability comparable to those of conventional horseradish-peroxidase-conjugated secondary antibodies, regardless of the target molecules, in various immunoassay formats, such as enzyme-linked immunosorbent assay, Western blot, and lateral flow assays. Each rILSA was selected for its own individual purpose and applied to various types of target analytes, in combination with a variety of target-specific primary antibodies, effectively minimizing the use of animals as well as reducing the costs and time associated with the production and chemical conjugation of signal-amplifying enzymes.
Collapse
|
48
|
Xu F, Jin Z, Zou S, Chen C, Song Q, Deng S, Xiao W, Zhang X, Jia A, Tang Y. EuNPs-mAb fluorescent probe based immunochromatographic strip for rapid and sensitive detection of porcine epidemic diarrhea virus. Talanta 2020; 214:120865. [PMID: 32278431 PMCID: PMC7111840 DOI: 10.1016/j.talanta.2020.120865] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 02/22/2020] [Accepted: 02/24/2020] [Indexed: 11/29/2022]
Abstract
Porcine epidemic diarrhea (PED), induced by porcine epidemic diarrhea virus (PEDV) causes acute diarrhea, vomiting, dehydration and high mortality in neonatal piglets, resulting in significant economic losses in the pig industries. In this study, an immunochromatographic assay (ICA) based on a EuNPs-mAb fluorescent probe was developed and optimized for rapid detection of PEDV. The limit of detection (LOD) of the ICA was 0.218 μg/mL (2.725 × 103 TCID50/mL) and its linear detection range was 0.03125-8 μg/mL (3.91 × 102-105 TCID50/mL). The ICA was also validated for the detection of PEDV in swine stool samples. 60 swine stool samples from southern China were analyzed by the ICA and RT-PCR, and the results showed that the coincidence rate of the ICA to RT-PCR was 86.67%, which was significantly higher than that of AuNPs based ICA. The ICA is sensitive and specific and can achieve on-site rapid detection of swine stool samples. Therefore, the ICA has a great potential for PED diagnosis and prevention.
Collapse
Affiliation(s)
- Fei Xu
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Zhiyuan Jin
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Siyi Zou
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Chaoqun Chen
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Qifang Song
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Shengchao Deng
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Wei Xiao
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Xiaoli Zhang
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China.
| | - Aiqing Jia
- Guangdong Haid Institute of Animal Husbandry & Veterinary, PR China.
| | - Yong Tang
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China; Institute of Food Safety and Nutrition, Jinan University, Guangzhou, 510632, PR China.
| |
Collapse
|
49
|
Tao D, McGill B, Hamerly T, Kobayashi T, Khare P, Dziedzic A, Leski T, Holtz A, Shull B, Jedlicka AE, Walzer A, Slowey PD, Slowey CC, Nsango SE, Stenger DA, Chaponda M, Mulenga M, Jacobsen KH, Sullivan DJ, Ryan SJ, Ansumana R, Moss WJ, Morlais I, Dinglasan RR. A saliva-based rapid test to quantify the infectious subclinical malaria parasite reservoir. Sci Transl Med 2020; 11:11/473/eaan4479. [PMID: 30602535 PMCID: PMC6441545 DOI: 10.1126/scitranslmed.aan4479] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Revised: 07/27/2018] [Accepted: 11/30/2018] [Indexed: 01/01/2023]
Abstract
A large proportion of ongoing malaria parasite transmission is attributed to low-density subclinical infections not readily detected by available rapid diagnostic tests (RDTs) or microscopy. Plasmodium falciparum gametocyte carriage is subclinical, but gametocytemic individuals comprise the parasite reservoir that leads to infection of mosquitoes and local transmission. Effective detection and quantification of these carriers can help advance malaria elimination strategies. However, no point-of-need (PON) RDTs for gametocyte detection exist, much less one that can perform noninvasive sampling of saliva outside a clinical setting. Here, we report on the discovery of 35 parasite markers from which we selected a single candidate for use in a PON RDT. We performed a cross-sectional, multi-omics study of saliva from 364 children with subclinical infection in Cameroon and Zambia and produced a prototype saliva-based PON lateral flow immunoassay test for P. falciparum gametocyte carriers. The test is capable of identifying submicroscopic carriage in both clinical and nonclinical settings and is compatible with archived saliva samples.
Collapse
Affiliation(s)
- Dingyin Tao
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA.,Johns Hopkins Malaria Research Institute, Baltimore, MD 21205, USA
| | - Brent McGill
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA.,Johns Hopkins Malaria Research Institute, Baltimore, MD 21205, USA
| | - Timothy Hamerly
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA.,Johns Hopkins Malaria Research Institute, Baltimore, MD 21205, USA.,Emerging Pathogens Institute and Department of Infectious Diseases & Immunology, College of Veterinary Medicine, University of Florida, Gainesville, FL 32611, USA
| | - Tamaki Kobayashi
- Johns Hopkins Malaria Research Institute, Baltimore, MD 21205, USA.,Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA
| | - Prachi Khare
- Emerging Pathogens Institute and Department of Infectious Diseases & Immunology, College of Veterinary Medicine, University of Florida, Gainesville, FL 32611, USA
| | - Amanda Dziedzic
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA
| | - Tomasz Leski
- United States Naval Research Laboratory (NRL), Center for Biomolecular Science and Engineering, Washington, DC 20375, USA
| | - Andrew Holtz
- College of Science, George Mason University, Fairfax, VA 22030, USA
| | - Bruce Shull
- Thermo Fisher Scientific, Fremont, CA 94538, USA
| | - Anne E Jedlicka
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA
| | | | | | | | - Sandrine E Nsango
- Laboratoire de Recherche sur le Paludisme, Institut de Recherche pour le Développement-Organisation de Coordination et de Coopération pour la Lutte Contre les Grandes Endémies en Afrique Centrale (IRD-OCEAC), Yaoundé, Cameroon.,Faculty of Medicine and Pharmaceutical Sciences, University of Douala, PO Box 2701, Douala, Cameroon
| | - David A Stenger
- United States Naval Research Laboratory (NRL), Center for Biomolecular Science and Engineering, Washington, DC 20375, USA
| | | | | | - Kathryn H Jacobsen
- College of Health and Human Services, George Mason University, Fairfax, VA 22030, USA
| | - David J Sullivan
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA
| | - Sadie J Ryan
- Emerging Pathogens Institute and Department of Geography, College of Liberal Arts and Sciences, University of Florida, Gainesville, FL 32611, USA
| | - Rashid Ansumana
- Mercy Hospital Research Laboratory, Kulanda Town, Bo, Sierra Leone
| | - William J Moss
- Johns Hopkins Malaria Research Institute, Baltimore, MD 21205, USA.,Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA
| | - Isabelle Morlais
- Laboratoire de Recherche sur le Paludisme, Institut de Recherche pour le Développement-Organisation de Coordination et de Coopération pour la Lutte Contre les Grandes Endémies en Afrique Centrale (IRD-OCEAC), Yaoundé, Cameroon
| | - Rhoel R Dinglasan
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA. .,Johns Hopkins Malaria Research Institute, Baltimore, MD 21205, USA.,Emerging Pathogens Institute and Department of Infectious Diseases & Immunology, College of Veterinary Medicine, University of Florida, Gainesville, FL 32611, USA
| |
Collapse
|
50
|
Huang Y, Xu T, Wang W, Wen Y, Li K, Qian L, Zhang X, Liu G. Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments. Mikrochim Acta 2019; 187:70. [PMID: 31853644 DOI: 10.1007/s00604-019-3822-x] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 09/12/2019] [Indexed: 12/25/2022]
Abstract
This review (with 187 refs.) summarizes the progress that has been made in the design of lateral flow biosensors (LFBs) based on the use of micro- and nano-materials. Following a short introduction into the field, a first section covers features related to the design of LFBs, with subsections on strip-based, cotton thread-based and vertical flow- and syringe-based LFBs. The next chapter summarizes methods for sample pretreatment, from simple method to membrane-based methods, pretreatment by magnetic methods to device-integrated sample preparation. Advances in flow control are treated next, with subsections on cross-flow strategies, delayed and controlled release and various other strategies. Detection conditionst and mathematical modelling are briefly introduced in the following chapter. A further chapter covers methods for reliability improvement, for example by adding other validation lines or adopting different detection methods. Signal readouts are summarized next, with subsections on color-based, luminescent, smartphone-based and SERS-based methods. A concluding section summarizes the current status and addresses challenges in future perspectives. Graphical abstractRecent development and breakthrough points of lateral flow biosensors.
Collapse
Affiliation(s)
- Yan Huang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China.,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA
| | - Tailin Xu
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Wenqian Wang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Yongqiang Wen
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Kun Li
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China
| | - Lisheng Qian
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.
| | - Xueji Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China. .,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,School of Biomedical Engineering, Shenzhen University Healthy Science Center, Shenzhen, Guangdong, 518060, People's Republic of China.
| | - Guodong Liu
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA.
| |
Collapse
|