1
|
Torné-Morató H, Pesenti L, Triphaty V, Pompa PP. Sensitivity-enhanced competitive lateral flow immunoassays by polycaprolactone electrospun stacking pad: Estrous determination in whole blood. Biosens Bioelectron 2025; 271:117080. [PMID: 39731824 DOI: 10.1016/j.bios.2024.117080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Accepted: 12/17/2024] [Indexed: 12/30/2024]
Abstract
Lateral flow assays (LFA) are widely adopted in point-of-care diagnostics across a spectrum of applications, due to their simplicity of use and cost-effectiveness. However, in complex biological matrices (e.g., whole blood), LFA sensitivity and analytical performance may be lower than those of laboratory-based techniques. Here, we introduce a polycaprolactone electrospun stacking pad designed to enhance the sensitivity of competitive LFAs. The stacking pad works as an automated pre-incubation step, promoting the analyte interaction with antibody conjugated gold nanoparticles, without affecting the test strip's flow dynamics. We assessed that the stacking pad allows accurate tuning of the flow rate, resulting in a significant increase in sensitivity in whole bovine blood, thereby achieving the required performance for the naked-eye detection of progesterone at the estrous threshold level (2 ng mL⁻1). The proposed method shows promising potential for broad adaptation to other immunoassays that demand enhanced sensitivity for on-site diagnostics.
Collapse
Affiliation(s)
- Helena Torné-Morató
- Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy; Department of Chemistry and Industrial Chemistry, University of Genova, Via Dodecaneso, 31, 16146, Genova, Italy
| | - Lucia Pesenti
- Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy
| | - Vinay Triphaty
- Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy
| | - Pier Paolo Pompa
- Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy.
| |
Collapse
|
2
|
Khatmi G, Klinavičius T, Simanavičius M, Silimavičius L, Tamulevičienė A, Rimkutė A, Kučinskaitė-Kodzė I, Gylys G, Tamulevičius T. Lateral flow assay sensitivity and signal enhancement via laser µ-machined constrains in nitrocellulose membrane. Sci Rep 2024; 14:22936. [PMID: 39358489 PMCID: PMC11446913 DOI: 10.1038/s41598-024-74407-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Accepted: 09/25/2024] [Indexed: 10/04/2024] Open
Abstract
Lateral flow assay (LFA) is a handful diagnostic technology that can identify severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other common respiratory viruses in one strip, which can be tested at the point-of-care without the need for equipment or skilled personnel outside the laboratory. Although its simplicity and practicality make it an appealing solution, it remains a grand challenge to substantially enhance the colorimetric LFA sensitivity. In this work, we present a straightforward approach to enhance the sensitivity of LFA by imposing the flow constraints in nitrocellulose (NC) membranes via a number of vertical femtosecond laser micromachined microchannels which is important for prolonged specific binding interactions. Porous NC membrane surfaces were structured with different widths and densities µ-channels employing a second harmonic of the Yb:KGW femtosecond laser and sample XYZ translation over a microscope objective-focused laser beam. The influence of the microchannel parameters on the vertical wicking speed was evaluated from the video recordings. The obtained results indicated that µ-channel length, width, and density in NC membranes controllably increased the immunological reaction time between the analyte and the labeled antibody by 950%. Image analysis of the colorimetric indicators confirmed that the flow rate delaying strategy enhanced the signal sensitives by 40% compared with pristine NC LFA.
Collapse
Affiliation(s)
- Gazy Khatmi
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania.
| | - Tomas Klinavičius
- Institute of Materials Science, Kaunas University of Technology, Kaunas, Lithuania
| | - Martynas Simanavičius
- Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Laimis Silimavičius
- UAB Sanpharm, Vilnius, Lithuania
- Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Asta Tamulevičienė
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania
- Institute of Materials Science, Kaunas University of Technology, Kaunas, Lithuania
| | - Agnė Rimkutė
- Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | | | | | - Tomas Tamulevičius
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania.
- Institute of Materials Science, Kaunas University of Technology, Kaunas, Lithuania.
| |
Collapse
|
3
|
Xu X, Nilghaz A, Wan X, Liu S, Xue M, Guo W, Tian J. A novel premixing strategy for highly sensitive detection of nitrite on paper-based analytical devices. Anal Chim Acta 2024; 1299:342417. [PMID: 38499414 DOI: 10.1016/j.aca.2024.342417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 02/04/2024] [Accepted: 02/25/2024] [Indexed: 03/20/2024]
Abstract
BACKGROUND Nitrite has been involved in many food processing techniques and its excessive consumption is closely related to the development of different diseases. Therefore, highly sensitive detection of nitrite is significant to ensure food safety. RESULT This study presents a simple and novel strategy for the highly sensitive detection of nitrite in food using paper-based analytical devices (PADs). In this proposed strategy, the nitrite present in the sample undergoes efficient diazotization when initially mixed with sulfanilamide solution before reacting with N-(1-naphthyl) ethylenediamine dihydrochloride (NED) coated on the detection region of the PAD, leading to the maximum production of colored azo compounds. Specifically, within the concentration range of 0.1-20 mg/L, the LOD and LOQ for the nitrite assay using the premixing strategy are determined as 0.053 mg/L and 0.18 mg/L, respectively which significantly surpass the corresponding values of 0.18 mg/L (LOD) and 0.61 mg/L (LOQ) achieved with the regular Griess reagent analysis. SIGNIFICANCE The study highlights the critical importance of the premixing strategy in nitrite detection. Under optimized conditions, the strategy demonstrates an excellent limit of detection (LOD) and limit of quantification (LOQ) for nitrite detection in eight different meat samples. In addition to its high precision, the strategy is applicable in the field of nitrite analysis. This strategy could facilitate rapid and cost-effective nitrite analysis in real food samples, ensuring food safety and quality analysis.
Collapse
Affiliation(s)
- Xiaohu Xu
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou, 510641, China
| | - Azadeh Nilghaz
- Institute for Frontier Materials, Deakin University, Waurn Ponds, Victoria, 3216, Australia; Drug Delivery, Disposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia
| | - Xiaofang Wan
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou, 510641, China
| | - Shan Liu
- School of Medicine, South China University of Technology, Guangzhou, 510006, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou, 510006, China.
| | - Meigui Xue
- Dongguan Polytechnic, Dongguan, 523808, Guangdong, China
| | - Wan Guo
- Zhejiang Kan New Mat Co Ltd, Lishui, 323300, Zhejiang, China
| | - Junfei Tian
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou, 510641, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou, 510006, China.
| |
Collapse
|
4
|
Dey MK, Iftesum M, Devireddy R, Gartia MR. New technologies and reagents in lateral flow assay (LFA) designs for enhancing accuracy and sensitivity. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4351-4376. [PMID: 37615701 DOI: 10.1039/d3ay00844d] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
Lateral flow assays (LFAs) are a popular method for quick and affordable diagnostic testing because they are easy to use, portable, and user-friendly. However, LFA design has always faced challenges regarding sensitivity, accuracy, and complexity of the operation. By integrating new technologies and reagents, the sensitivity and accuracy of LFAs can be improved while minimizing the complexity and potential for false positives. Surface enhanced Raman spectroscopy (SERS), photoacoustic techniques, fluorescence resonance energy transfer (FRET), and the integration of smartphones and thermal readers can improve LFA accuracy and sensitivity. To ensure reliable and accurate results, careful assay design and validation, appropriate controls, and optimization of assay conditions are necessary. Continued innovation in LFA technology is crucial to improving the reliability and accuracy of rapid diagnostic testing and expanding its applications to various areas, such as food testing, water quality monitoring, and environmental testing.
Collapse
Affiliation(s)
- Mohan Kumar Dey
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Maria Iftesum
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Ram Devireddy
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Manas Ranjan Gartia
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| |
Collapse
|
5
|
Atay E, Altan A. Nanomaterial interfaces designed with different biorecognition elements for biosensing of key foodborne pathogens. Compr Rev Food Sci Food Saf 2023; 22:3151-3184. [PMID: 37222549 DOI: 10.1111/1541-4337.13179] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 05/01/2023] [Accepted: 05/02/2023] [Indexed: 05/25/2023]
Abstract
Foodborne diseases caused by pathogen bacteria are a serious problem toward the safety of human life in a worldwide. Conventional methods for pathogen bacteria detection have several handicaps, including trained personnel requirement, low sensitivity, laborious enrichment steps, low selectivity, and long-term experiments. There is a need for precise and rapid identification and detection of foodborne pathogens. Biosensors are a remarkable alternative for the detection of foodborne bacteria compared to conventional methods. In recent years, there are different strategies for the designing of specific and sensitive biosensors. Researchers activated to develop enhanced biosensors with different transducer and recognition elements. Thus, the aim of this study was to provide a topical and detailed review on aptamer, nanofiber, and metal organic framework-based biosensors for the detection of food pathogens. First, the conventional methods, type of biosensors, common transducer, and recognition element were systematically explained. Then, novel signal amplification materials and nanomaterials were introduced. Last, current shortcomings were emphasized, and future alternatives were discussed.
Collapse
Affiliation(s)
- Elif Atay
- Department of Food Engineering, Mersin University, Mersin, Turkey
| | - Aylin Altan
- Department of Food Engineering, Mersin University, Mersin, Turkey
| |
Collapse
|
6
|
Tang R, Xie M, Yan X, Qian L, Giesy JP, Xie Y. A nitrocellulose/cotton fiber hybrid composite membrane for paper-based biosensor. CELLULOSE (LONDON, ENGLAND) 2023; 30:1-13. [PMID: 37360890 PMCID: PMC10238769 DOI: 10.1007/s10570-023-05288-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 05/24/2023] [Indexed: 06/28/2023]
Abstract
Nitrocellulose (NC) membrane was fabricated and tested for its potential use in various paper-based biosensors for use in point-of-care testing. However, contemporary technologies are complex, expensive, non-scalable, limited by conditions, and beset with potentially adverse effects on the environment. Herein, we proposed a simple, cost-effective, scalable technology to prepare nitrocellulose/cotton fiber (NC/CF) composite membranes. The NC/CF composite membranes with a diameter of 20 cm were fabricated in 15 min using papermaking technology, which contributes to scalability in the large-scale production of these composites. Compared with existing commercial NC membranes, the NC/CF composite membrane is characterized by small pore size (3.59 ± 0.19 μm), low flow rate (156 ± 55 s/40 mm), high dry strength (up to 4.04 MPa), and wet strength (up to 0.13 MPa), adjustable hydrophilic-hydrophobic (contact angles ranged from 29 ± 4.6 to 82.8 ± 2.4°), the good adsorption capacity of protein (up to 91.92 ± 0.07 μg). After lateral flow assays (LFAs) detection, the limit of detection is 1 nM, which is similar to commercial NC membrane (Sartorius CN 140). We envision the NC/CF composite membrane as a promising material for paper-based biosensors of point-of-care testing applications.
Collapse
Affiliation(s)
- Ruihua Tang
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
- National Demonstration Center for Experimental Light Chemistry Engineering Education, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - Mingyue Xie
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
- National Demonstration Center for Experimental Light Chemistry Engineering Education, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - Xueyan Yan
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
- National Demonstration Center for Experimental Light Chemistry Engineering Education, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - Liwei Qian
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
- National Demonstration Center for Experimental Light Chemistry Engineering Education, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - John P. Giesy
- Toxicology Center, University of Saskatchewan, 44 Campus Dr, Saskatoon, S7N 5B3 Saskatchewan Canada
- Department of Veterinary Biomedical Sciences, University of Saskatchewan, Saskatoon, SK S7N 5B4 Canada
- Department of Integrative Biology and Center for Integrative Toxicology, Michigan State University, East Lansing, MI 48824 USA
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798-7266 USA
| | - Yuwei Xie
- Ministry of Ecology and Environment, Nanjing Institute of Environmental Sciences, Nanjing, 210042 China
| |
Collapse
|
7
|
Solovov R, Kazberova A, Ershov B. Special Aspects of Nitrocellulose Molar Mass Determination by Dynamic Light Scattering. Polymers (Basel) 2023; 15:polym15020263. [PMID: 36679145 PMCID: PMC9862043 DOI: 10.3390/polym15020263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 12/21/2022] [Accepted: 12/23/2022] [Indexed: 01/06/2023] Open
Abstract
The dynamic light scattering method was successfully applied to determine the molar mass of nitrocellulose. The methodology of nitrocellulose fractionation in acetonic solutions is described in detail; six polymer fractions with monomodal distribution were obtained. It was shown that the unfractionated colloxylin with polymodal molar mass distribution had mass average molecular mass values of 87.3 ± 14.1, 28.3 ± 7.3, and 0.54 ± 0.17 kDa when investigated by the dynamic light scattering method. The viscometric method only provided integral viscosity average molar mass equal to 56.7 ± 5.8 kDa.
Collapse
|
8
|
Cherusseri J, Savio CM, Khalid M, Chaudhary V, Numan A, Varma SJ, Menon A, Kaushik A. SARS-CoV-2-on-Chip for Long COVID Management. BIOSENSORS 2022; 12:890. [PMID: 36291027 PMCID: PMC9599615 DOI: 10.3390/bios12100890] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 06/16/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has become a "wicked evil" in this century due to its extended progression and huge human mortalities. Although the diagnosis of SARS-CoV-2 viral infection is made simple and practical by employing reverse transcription polymerase chain reaction (RT-PCR) investigation, the process is costly, complex, time-consuming, and requires experts for testing and the constraints of a laboratory. Therefore, these challenges have raised the paradigm of on-site portable biosensors on a single chip, which reduces human resources and enables remote access to minimize the overwhelming burden on the existing global healthcare sector. This article reviews the recent advancements in biosensors for long coronavirus disease (COVID) management using a multitude of devices, such as point-of-care biosensors and lab-on-chip biosensors. Furthermore, it details the shift in the paradigm of SARS-CoV-2-on-chip biosensors from the laboratory to on-site detection with intelligent and economical operation, representing near-future diagnostic technologies for public health emergency management.
Collapse
Affiliation(s)
- Jayesh Cherusseri
- Graphene & Advanced 2D Materials Research Group (GAMRG), School of Engineering and Technology, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, Petaling Jaya 47500, Malaysia
| | - Claire Mary Savio
- Department of Engineering, Amity University Dubai, Dubai International Academic City P.O. Box 345019, United Arab Emirates
| | - Mohammad Khalid
- Graphene & Advanced 2D Materials Research Group (GAMRG), School of Engineering and Technology, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, Petaling Jaya 47500, Malaysia
- Sunway Materials Smart Science & Engineering (SMS2E) Research Cluster, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, Petaling Jaya 47500, Malaysia
| | - Vishal Chaudhary
- Research Cell & Department of Physics, Bhagini Nivedita College, University of Delhi, Delhi 110043, India
- SUMAN Laboratory (Sustainable Materials and Advanced Nanotechnology), New Delhi 110072, India
| | - Arshid Numan
- Graphene & Advanced 2D Materials Research Group (GAMRG), School of Engineering and Technology, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, Petaling Jaya 47500, Malaysia
- Sunway Materials Smart Science & Engineering (SMS2E) Research Cluster, Sunway University, No. 5, Jalan Universiti, Bandar Sunway, Petaling Jaya 47500, Malaysia
| | - Sreekanth J. Varma
- Materials for Energy Storage and Optoelectronic Devices Group, Department of Physics, Sanatana Dharma College, University of Kerala, Alappuzha 688003, India
| | - Amrutha Menon
- Advanced Bio-Energy Devices Laboratory, Research & Development Division, JC Puli Energy Private Limited, Koduvayur, Palakkad 678501, India
| | - Ajeet Kaushik
- NanoBioTech Laboratory, Health System Engineering, Department of Environmental Engineering, Florida Polytechnic University, Lakeland, FL 33805, USA
- School of Engineering, University of Petroleum and Energy Studies (UPES), Dehradun 248007, India
| |
Collapse
|
9
|
Chatterjee S, Mukhopadhyay S. Recent advances of lateral flow immunoassay components as “point of need”. J Immunoassay Immunochem 2022; 43:579-604. [DOI: 10.1080/15321819.2022.2122063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Susraba Chatterjee
- Department of Laboratory Medicine, School of Tropical Medicine, 108, C.R.Avenue, Kolkata 700073, West Bengal
| | - Sumi Mukhopadhyay
- Department of Laboratory Medicine, School of Tropical Medicine, 108, C.R.Avenue, Kolkata 700073, West Bengal
| |
Collapse
|
10
|
Sena-Torralba A, Álvarez-Diduk R, Parolo C, Piper A, Merkoçi A. Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials. Chem Rev 2022; 122:14881-14910. [PMID: 36067039 PMCID: PMC9523712 DOI: 10.1021/acs.chemrev.1c01012] [Citation(s) in RCA: 118] [Impact Index Per Article: 39.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
![]()
Lateral flow assays (LFAs) are currently the most used
point-of-care
sensors for both diagnostic (e.g., pregnancy test, COVID-19 monitoring)
and environmental (e.g., pesticides and bacterial monitoring) applications.
Although the core of LFA technology was developed several decades
ago, in recent years the integration of novel nanomaterials as signal
transducers or receptor immobilization platforms has brought improved
analytical capabilities. In this Review, we present how nanomaterial-based
LFAs can address the inherent challenges of point-of-care (PoC) diagnostics
such as sensitivity enhancement, lowering of detection limits, multiplexing,
and quantification of analytes in complex samples. Specifically, we
highlight the strategies that can synergistically solve the limitations
of current LFAs and that have proven commercial feasibility. Finally,
we discuss the barriers toward commercialization and the next generation
of LFAs.
Collapse
Affiliation(s)
- Amadeo Sena-Torralba
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain.,Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain
| | - Ruslan Álvarez-Diduk
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Claudio Parolo
- Barcelona Institute for Global Health (ISGlobal) Hospital Clínic-Universitat de Barcelona, Carrer del Rosselló 132, 08036 Barcelona, Spain
| | - Andrew Piper
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain.,Catalan Institution for Research and Advanced Studies (ICREA), Pg. Lluís Companys 23, 08010 Barcelona, Spain
| |
Collapse
|
11
|
A Novel Lateral Flow Immunochromatographic Assay for Rapid and Simultaneous Detection of Aflatoxin B1 and Zearalenone in Food and Feed Samples Based on Highly Sensitive and Specific Monoclonal Antibodies. Toxins (Basel) 2022; 14:toxins14090615. [PMID: 36136553 PMCID: PMC9505352 DOI: 10.3390/toxins14090615] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/28/2022] [Accepted: 08/31/2022] [Indexed: 12/02/2022] Open
Abstract
Simultaneous aflatoxin (AFB1) and zearalenone (ZEN) contamination in agro-products have become widespread globally and have a toxic superposition effect. In the present study, we describe a highly sensitive and specific dual lateral flow immunochromatographic assay (dual test strip) for rapid and simultaneous detection of AFB1 and ZEN in food and feed samples based on respective monoclonal antibodies (mAbs). Two immunogens AFB1-BSA (an AFB1 and bovine serum albumin (BSA) conjugate) and ZEN-BSA (a ZEN and BSA conjugate) were synthesized in oximation active ester (OAE) and amino glutaraldehyde (AGA). The molecular binding ratio of AFB1:BSA was 8.64:1, and that of ZEN:BSA was 17.2:1, identified by high-resolution mass spectrometry (HRMS) and an ultraviolet spectrometer (UV). The hybridoma cell lines 2A11, 2F6, and 3G2 for AFB1 and 2B6, 4D9 for ZEN were filtered by an indirect non-competitive enzyme-linked immunosorbent assay (inELISA) and an indirect competitive enzyme-linked immunosorbent assay (icELISA), respectively. As AFB1 mAb 2A11 and ZEN mAb 2B6 had the lowest 50% inhibitive concentration (IC50) and cross-reactivity (CR), they were selected for subsequent experiments. By systematically optimizing the preparation condition of gold nanoparticles (AuNPs), AuNPs-labeled mAbs, and detection condition, the visual limit of detection (LOD) of the dual test strip was 1.0 μg/L for AFB1 and 5.0 μg/L for ZEN, whereas that of the test strip reader was 0.23 μg/L for AFB1 and 1.53 μg/L for ZEN. The high reproducibility and stability of the dual test were verified using mycotoxin-spiked samples. The dual test strips were highly specific and sensitive for AFB1 and ZEN, which were validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Thus, the proposed AFB1 and ZEN dual test strip is suitable for rapid and simultaneous detection of AFB1 and ZEN contamination in food and feed samples.
Collapse
|
12
|
Das A, Ringu T, Ghosh S, Pramanik N. A comprehensive review on recent advances in preparation, physicochemical characterization, and bioengineering applications of biopolymers. Polym Bull (Berl) 2022; 80:7247-7312. [PMID: 36043186 PMCID: PMC9409625 DOI: 10.1007/s00289-022-04443-4] [Citation(s) in RCA: 58] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 07/20/2022] [Accepted: 08/15/2022] [Indexed: 12/01/2022]
Abstract
Biopolymers are mainly the polymers which are created or obtained from living creatures such as plants and bacteria rather than petroleum, which has traditionally been the source of polymers. Biopolymers are chain-like molecules composed of repeated chemical blocks derived from renewable resources that may decay in the environment. The usage of biomaterials is becoming more popular as a means of reducing the use of non-renewable resources and reducing environmental pollution produced by synthetic materials. Biopolymers' biodegradability and non-toxic nature help to maintain our environment clean and safe. This study discusses how to improve the mechanical and physical characteristics of biopolymers, particularly in the realm of bioengineering. The paper begins with a fundamental introduction and progresses to a detailed examination of synthesis and a unique investigation of several recent focused biopolymers with mechanical, physical, and biological characterization. Biopolymers' unique non-toxicity, biodegradability, biocompatibility, and eco-friendly features are boosting their applications, especially in bioengineering fields, including agriculture, pharmaceuticals, biomedical, ecological, industrial, aqua treatment, and food packaging, among others, at the end of this paper. The purpose of this paper is to provide an overview of the relevance of biopolymers in smart and novel bioengineering applications. Graphical abstract The Graphical abstract represents the biological sources and applications of biopolymers. Plants, bacteria, animals, agriculture wastes, and fossils are all biological sources for biopolymers, which are chemically manufactured from biological monomer units, including sugars, amino acids, natural fats and oils, and nucleotides. Biopolymer modification (chemical or physical) is recognized as a crucial technique for modifying physical and chemical characteristics, resulting in novel materials with improved capabilities and allowing them to be explored to their full potential in many fields of application such as tissue engineering, drug delivery, agriculture, biomedical, food industries, and industrial applications.
Collapse
Affiliation(s)
- Abinash Das
- Department of Chemistry, National Institute of Technology, Arunachal Pradesh, Jote, Arunachal Pradesh 791113 India
| | - Togam Ringu
- Department of Chemistry, National Institute of Technology, Arunachal Pradesh, Jote, Arunachal Pradesh 791113 India
| | - Sampad Ghosh
- Department of Chemistry, Nalanda College of Engineering, Nalanda, Bihar 803108 India
| | - Nabakumar Pramanik
- Department of Chemistry, National Institute of Technology, Arunachal Pradesh, Jote, Arunachal Pradesh 791113 India
| |
Collapse
|
13
|
Sun Y, Jiang Q, Chen F, Cao Y. Paper‐based electrochemical sensor. ELECTROCHEMICAL SCIENCE ADVANCES 2022. [DOI: 10.1002/elsa.202100057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- Yang Sun
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| | - Qiao‐Yan Jiang
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| | - Feng Chen
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| | - Yue Cao
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| |
Collapse
|
14
|
Asghari S, Ekrami E, Barati F, Avatefi M, Mahmoudifard M. The role of the nanofibers in lateral flow assays enhancement: a critical review. INT J POLYM MATER PO 2022. [DOI: 10.1080/00914037.2022.2090360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Sahar Asghari
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Elena Ekrami
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Fatemeh Barati
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Manizheh Avatefi
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Matin Mahmoudifard
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| |
Collapse
|
15
|
Landry V, Coburn P, Kost K, Liu X, Li-Jessen NYK. Diagnostic Accuracy of Liquid Biomarkers in Airway Diseases: Toward Point-of-Care Applications. Front Med (Lausanne) 2022; 9:855250. [PMID: 35733871 PMCID: PMC9207186 DOI: 10.3389/fmed.2022.855250] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 05/04/2022] [Indexed: 12/30/2022] Open
Abstract
Background Liquid biomarkers have shown increasing utility in the clinical management of airway diseases. Salivary and blood samples are particularly amenable to point-of-care (POC) testing due to simple specimen collection and processing. However, very few POC tests have successfully progressed to clinical application due to the uncertainty and unpredictability surrounding their diagnostic accuracy. Objective To review liquid biomarkers of airway diseases with well-established diagnostic accuracies and discuss their prospects for future POC applications. Methodology A literature review of publications indexed in Medline or Embase was performed to evaluate the diagnostic accuracy of liquid biomarkers for chronic obstructive pulmonary disease (COPD), asthma, laryngopharyngeal reflux (LPR), and COVID-19. Results Of 3,628 studies, 71 fulfilled the inclusion criteria. Sputum and blood eosinophils were the most frequently investigated biomarkers for the management of asthma and COPD. Salivary pepsin was the only biomarker with a well-documented accuracy for the diagnosis of LPR. Inflammatory blood biomarkers (e.g., CRP, D-dimers, ferritin) were found to be useful to predict the severity, complications, and mortality related to COVID-19 infection. Conclusion Multiple liquid biomarkers have well-established diagnostic accuracies and are thus amenable to POC testing in clinical settings.
Collapse
Affiliation(s)
- Vivianne Landry
- Faculty of Medicine, University of Montreal, Montreal, QC, Canada
- School of Communication Sciences & Disorders, McGill University, Montreal, QC, Canada
| | - Patrick Coburn
- School of Communication Sciences & Disorders, McGill University, Montreal, QC, Canada
| | - Karen Kost
- Department of Otolaryngology-Head & Neck Surgery, McGill University, Montreal, QC, Canada
| | - Xinyu Liu
- Department of Mechanical & Industrial Engineering, University of Toronto, Toronto, ON, Canada
| | - Nicole Y. K. Li-Jessen
- School of Communication Sciences & Disorders, McGill University, Montreal, QC, Canada
- Department of Otolaryngology-Head & Neck Surgery, McGill University, Montreal, QC, Canada
- Department of Biomedical Engineering, McGill University, Montreal, QC, Canada
- The Research Institute of the McGill University Health Centre, Montreal, QC, Canada
| |
Collapse
|
16
|
Pavlova E, Maslakova A, Prusakov K, Bagrov D. Optical sensors based on electrospun membranes – principles, applications, and prospects for chemistry and biology. NEW J CHEM 2022. [DOI: 10.1039/d2nj01821g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Electrospun membranes are promising substrates for receptor layer immobilization in optical sensors. Either colorimetric, luminescence, or Raman scattering signal can be used to detect the analyte.
Collapse
Affiliation(s)
- Elizaveta Pavlova
- Lomonosov Moscow State University, Faculty of Biology, Leninskie Gory 1-12, 119234, Moscow, Russian Federation
- Federal Research Clinical Center of Physical–Chemical Medicine of the Federal Medical and Biological Agency of Russia, 1a Malaya Pirogovskaya Street, 119435, Moscow, Russian Federation
| | - Aitsana Maslakova
- Lomonosov Moscow State University, Faculty of Biology, Leninskie Gory 1-12, 119234, Moscow, Russian Federation
| | - Kirill Prusakov
- Lomonosov Moscow State University, Faculty of Biology, Leninskie Gory 1-12, 119234, Moscow, Russian Federation
- Federal Research Clinical Center of Physical–Chemical Medicine of the Federal Medical and Biological Agency of Russia, 1a Malaya Pirogovskaya Street, 119435, Moscow, Russian Federation
| | - Dmitry Bagrov
- Lomonosov Moscow State University, Faculty of Biology, Leninskie Gory 1-12, 119234, Moscow, Russian Federation
| |
Collapse
|
17
|
Hussin NH, Wahab RA, Elias N, Jacob AG, Zainal-Abidin MH, Abdullah F, Sulaiman NJ, Misson M. Electrospun Magnetic Nanocellulose-Polyethersulfone-Conjugated Aspergillus oryzae Lipase for Synthesis of Ethyl Valerate. MEMBRANES 2021; 11:972. [PMID: 34940473 PMCID: PMC8707156 DOI: 10.3390/membranes11120972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/30/2021] [Accepted: 12/02/2021] [Indexed: 11/20/2022]
Abstract
A novel greener MNC/PES membrane was developed through an electrospinning technique for lipase immobilization to catalyze the synthesis of ethyl valerate (EV). In this study, the covalent immobilization of Aspergillus oryzae lipase (AOL) onto an electrospun nanofibrous membrane consisting of magnetic nanocellulose (MNC) and polyethersulfone (PES) to produce EV was statistically optimized. Raman spectroscopy, Fourier-transform infrared spectroscopy: attenuated total reflection, field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, thermal gravimetric analysis (TGA), and differential thermal gravimetric (DTG) of MNC/PES-AOL demonstrated that AOL was successfully immobilized onto the fibers. The Taguchi design-assisted immobilization of AOL onto MNC/PES fibers identified that 1.10 mg/mL protein loading, 4 mL reaction volume, 250 rpm stirring rate, and 50 °C were optimal to yield 72.09% of EV in 24 h. The thermal stability of MNC/PES-AOL was improved by ≈20% over the free AOL, with reusability for up to five consecutive esterification cycles while demonstrating an exceptional half-life of 120 h. Briefly, the electrospun MNC/PES fibers that immobilized AOL showed promising applicability in yielding relatively good EV levels. This study suggests that using MNC as fillers in a PES to improve AOL activity and durability for a longer catalytic process could be a viable option.
Collapse
Affiliation(s)
- Nurul Hidayah Hussin
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia; (N.H.H.); (N.E.); (A.G.J.); (M.H.Z.-A.); (F.A.)
- Enzyme Technology and Green Synthesis Group, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia
| | - Roswanira Abdul Wahab
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia; (N.H.H.); (N.E.); (A.G.J.); (M.H.Z.-A.); (F.A.)
- Enzyme Technology and Green Synthesis Group, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia
| | - Nursyafiqah Elias
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia; (N.H.H.); (N.E.); (A.G.J.); (M.H.Z.-A.); (F.A.)
- Enzyme Technology and Green Synthesis Group, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia
| | - Adikwu Gowon Jacob
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia; (N.H.H.); (N.E.); (A.G.J.); (M.H.Z.-A.); (F.A.)
- Enzyme Technology and Green Synthesis Group, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia
- Department of Applied Chemistry, Federal University Dutsin-Ma (FUDMA), Dutsin-Ma P.M.B 5001, Katsina State, Nigeria
| | - Mohamad Hamdi Zainal-Abidin
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia; (N.H.H.); (N.E.); (A.G.J.); (M.H.Z.-A.); (F.A.)
| | - Faizuan Abdullah
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia; (N.H.H.); (N.E.); (A.G.J.); (M.H.Z.-A.); (F.A.)
| | - Nurul Jannah Sulaiman
- Department of Bioprocess & Polymer Engineering, School of Chemical & Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia (UTM), Johor Bahru 81310, Johor, Malaysia;
| | - Mailin Misson
- Biotechnology Research Institute, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu 88400, Sabah, Malaysia
| |
Collapse
|
18
|
Lateral flow assays (LFA) as an alternative medical diagnosis method for detection of virus species: The intertwine of nanotechnology with sensing strategies. Trends Analyt Chem 2021; 145:116460. [PMID: 34697511 PMCID: PMC8529554 DOI: 10.1016/j.trac.2021.116460] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Viruses are responsible for multiple infections in humans that impose huge health burdens on individuals and populations worldwide. Therefore, numerous diagnostic methods and strategies have been developed for prevention, management, and decreasing the burden of viral diseases, each having its advantages and limitations. Viral infections are commonly detected using serological and nucleic acid-based methods. However, these conventional and clinical approaches have some limitations that can be resolved by implementing other detector devices. Therefore, the search for sensitive, selective, portable, and costless approaches as efficient alternative clinical methods for point of care testing (POCT) analysis has gained much attention in recent years. POCT is one of the ultimate goals in virus detection, and thus, the tests need to be rapid, specific, sensitive, accessible, and user-friendly. In this review, after a brief overview of viruses and their characteristics, the conventional viral detection methods, the clinical approaches, and their advantages and shortcomings are firstly explained. Then, LFA systems working principles, benefits, classification are discussed. Furthermore, the studies regarding designing and employing LFAs in diagnosing different types of viruses, especially SARS-CoV-2 as a main concern worldwide and innovations in the LFAs' approaches and designs, are comprehensively discussed here. Furthermore, several strategies addressed in some studies for overcoming LFA limitations like low sensitivity are reviewed. Numerous techniques are adopted to increase sensitivity and perform quantitative detection. Employing several visualization methods, using different labeling reporters, integrating LFAs with other detection methods to benefit from both LFA and the integrated detection device advantages, and designing unique membranes to increase reagent reactivity, are some of the approaches that are highlighted.
Collapse
|
19
|
Imbibition of Newtonian Fluids in Paper-like Materials with the Infinitesimal Control Volume Method. MICROMACHINES 2021; 12:mi12111391. [PMID: 34832802 PMCID: PMC8626007 DOI: 10.3390/mi12111391] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 10/31/2021] [Accepted: 11/10/2021] [Indexed: 12/26/2022]
Abstract
Paper-based microfluidic devices are widely used in point-of-care testing applications. Imbibition study of paper porous media is important for fluid controlling, and then significant to the applications of paper-based microfluidic devices. Here we propose an analytical approach based on the infinitesimal control volume method to study the imbibition of Newtonian fluids in commonly used paper-like materials. Three common paper shapes (rectangular paper strips, fan-shaped and circular paper sheets) are investigated with three modeling methods (corresponding to equivalent tiny pores with circle, square and regular triangle cross section respectively). A model is derived for liquid imbibition in rectangular paper strips, and the control equations for liquid imbibition in fan-shaped and circular paper sheets are also derived. The model is verified by imbibition experiments done using the mixed cellulose ester filter paper and pure water. The relation of imbibition distance and time is similar to that of the Lucas−Washburn (L−W) model. In addition, a new porosity measurement method based on the imbibition in circular paper sheets is proposed and verified. Finally, the flow rates are investigated. This study can provide guidance for the design of different shapes of paper, and for better applications of paper-based microfluidic devices.
Collapse
|
20
|
Ranjan S, Jain S, Bhargava A, Shandilya R, Srivastava RK, Mishra PK. Lateral flow assay-based detection of long non-coding RNAs: A point-of-care platform for cancer diagnosis. J Pharm Biomed Anal 2021; 204:114285. [PMID: 34333453 DOI: 10.1016/j.jpba.2021.114285] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 07/23/2021] [Accepted: 07/23/2021] [Indexed: 12/13/2022]
Abstract
Lateral flow assay (LFA) is a flexible, simple, low-costpoint-of-care platform for rapid detection of disease-specific biomarkers. Importantly, the ability of the assay to capture the circulating bio-molecules has gained significant attention, as it offers a potential minimal invasive system for early disease diagnosis and prognosis. In the present article, we review an innovative concept of LFA-based detection of circulating long non-coding RNAs (lncRNAs), one of the key regulators of fundamental biological processes. In addition, their disease-specific expression pattern and presence in biological fluids at differential levels make them excellent biomarker candidates for cancer detection. Our article also provides an update on the requirements for developing and improving such systems and discusses the key aspects of material selection, operational concepts, principles and conceptual design. We assume that the reviewed points will be helpful to improve the diagnostic applicability of LFA based lncRNA detection in cancer diagnosis.
Collapse
Affiliation(s)
- Shashi Ranjan
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental Health, Bhopal, India
| | - Surbhi Jain
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental Health, Bhopal, India
| | - Arpit Bhargava
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental Health, Bhopal, India
| | - Ruchita Shandilya
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental Health, Bhopal, India
| | | | - Pradyumna Kumar Mishra
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental Health, Bhopal, India.
| |
Collapse
|
21
|
Wang X, Xue CH, Yang D, Jia ST, Ding YR, Lei L, Gao KY, Jia TT. Modification of a nitrocellulose membrane with nanofibers for sensitivity enhancement in lateral flow test strips. RSC Adv 2021; 11:26493-26501. [PMID: 35479983 PMCID: PMC9037416 DOI: 10.1039/d1ra04369b] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 07/23/2021] [Indexed: 01/16/2023] Open
Abstract
Lateral-flow analysis (LFA) is a convenient, low-cost, and rapid detection method, which has been widely used for screening of diseases. However, sensitivity enhancement in LFA is still a focus in this field and remains challenging. Herein, we propose an electrospinning coating method to modify the conventional nitrocellulose (NC) membrane and optimize the liquid flow rate for enhancing the sensitivity of the NC based LFA strips in the detection of human chorionic gonadotropin (HCG) and luteinizing hormone (LH). It can be seen that coating the NC membrane with nitrocellulose fibers could obtain a NC based strip with HCG and LH detection limits of 0.22 and 0.36 mIU mL-1 respectively, and a quantitative linear range of 0.5-500 mIU mL-1. The results show that electrospinning is effective in modifying conventional NC membranes for LFA applications.
Collapse
Affiliation(s)
- Xue Wang
- College of Environmental Science and Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Chao-Hua Xue
- College of Environmental Science and Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Dong Yang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Shun-Tian Jia
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Ya-Ru Ding
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Lei Lei
- College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Ke-Yi Gao
- College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| | - Tong-Tong Jia
- College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology Xi'an 710021 China
| |
Collapse
|
22
|
Rasmi Y, Li X, Khan J, Ozer T, Choi JR. Emerging point-of-care biosensors for rapid diagnosis of COVID-19: current progress, challenges, and future prospects. Anal Bioanal Chem 2021; 413:4137-4159. [PMID: 34008124 PMCID: PMC8130795 DOI: 10.1007/s00216-021-03377-6] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Accepted: 04/26/2021] [Indexed: 02/07/2023]
Abstract
Coronavirus disease 2019 (COVID-19) pandemic is currently a serious global health threat. While conventional laboratory tests such as quantitative real-time polymerase chain reaction (qPCR), serology tests, and chest computerized tomography (CT) scan allow diagnosis of COVID-19, these tests are time-consuming and laborious, and are limited in resource-limited settings or developing countries. Point-of-care (POC) biosensors such as chip-based and paper-based biosensors are typically rapid, portable, cost-effective, and user-friendly, which can be used for COVID-19 in remote settings. The escalating demand for rapid diagnosis of COVID-19 presents a strong need for a timely and comprehensive review on the POC biosensors for COVID-19 that meet ASSURED criteria: Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end users. In the present review, we discuss the importance of rapid and early diagnosis of COVID-19 and pathogenesis of COVID-19 along with the key diagnostic biomarkers. We critically review the most recent advances in POC biosensors which show great promise for the detection of COVID-19 based on three main categories: chip-based biosensors, paper-based biosensors, and other biosensors. We subsequently discuss the key benefits of these biosensors and their use for the detection of antigen, antibody, and viral nucleic acids. The commercial POC biosensors for COVID-19 are critically compared. Finally, we discuss the key challenges and future perspectives of developing emerging POC biosensors for COVID-19. This review would be very useful for guiding strategies for developing and commercializing rapid POC tests to manage the spread of infections.Graphical abstract.
Collapse
Affiliation(s)
- Yousef Rasmi
- Department of Biochemistry, Faculty of Medicine, Urmia University of Medical Sciences, 5714783734, Urmia, Iran
- Cellular and Molecular Research Center, Urmia University of Medical Sciences, 5714783734, Urmia, Iran
| | - Xiaokang Li
- Ludwig Institute for Cancer Research, University of Lausanne, Agora Center, 1005, Lausanne, Switzerland
- Department of Oncology, Centre hospitalier universitaire vaudois (CHUV), 1011, Lausanne, Switzerland
| | - Johra Khan
- Department of Medical Laboratory Sciences, College of Applied Medical Sciences, Majmaah University, Majmaah, 11952, Kingdom of Saudi Arabia
| | - Tugba Ozer
- Department of Bioengineering, Faculty of Chemical-Metallurgical Engineering, Yildiz Technical University, 34220, Istanbul, Turkey
| | - Jane Ru Choi
- Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
- Centre for Blood Research, Life Sciences Centre, University of British Columbia, Vancouver, BC, V6T 1Z3, Canada.
| |
Collapse
|
23
|
Hoang TX, Phan LMT, Vo TAT, Cho S. Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review. Biomedicines 2021; 9:540. [PMID: 34066112 PMCID: PMC8150371 DOI: 10.3390/biomedicines9050540] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/05/2021] [Accepted: 05/10/2021] [Indexed: 11/21/2022] Open
Abstract
Paper-based analytical devices (PADs) have emerged as a promising approach to point-of-care (POC) detection applications in biomedical and clinical diagnosis owing to their advantages, including cost-effectiveness, ease of use, and rapid responses as well as for being equipment-free, disposable, and user-friendly. However, the overall sensitivity of PADs still remains weak, posing a challenge for biosensing scientists exploiting them in clinical applications. This review comprehensively summarizes the current applicable potential of PADs, focusing on total signal-amplification strategies that have been applied widely in PADs involving colorimetry, luminescence, surface-enhanced Raman scattering, photoacoustic, photothermal, and photoelectrochemical methods as well as nucleic acid-mediated PAD modifications. The advances in signal-amplification strategies in terms of signal-enhancing principles, sensitivity, and time reactions are discussed in detail to provide an overview of these approaches to using PADs in biosensing applications. Furthermore, a comparison of these methods summarizes the potential for scientists to develop superior PADs. This review serves as a useful inside look at the current progress and prospective directions in using PADs for clinical diagnostics and provides a better source of reference for further investigations, as well as innovations, in the POC diagnostics field.
Collapse
Affiliation(s)
- Thi Xoan Hoang
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-do, Korea; (T.X.H.); (T.A.T.V.)
| | - Le Minh Tu Phan
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Gyeonggi-do, Korea
- School of Medicine and Pharmacy, The University of Danang, Danang 550000, Vietnam
| | - Thuy Anh Thu Vo
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-do, Korea; (T.X.H.); (T.A.T.V.)
| | - Sungbo Cho
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Gyeonggi-do, Korea
- Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Korea
| |
Collapse
|
24
|
Zhong J, Rösch EL, Viereck T, Schilling M, Ludwig F. Toward Rapid and Sensitive Detection of SARS-CoV-2 with Functionalized Magnetic Nanoparticles. ACS Sens 2021; 6:976-984. [PMID: 33496572 PMCID: PMC7860137 DOI: 10.1021/acssensors.0c02160] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 01/18/2021] [Indexed: 12/17/2022]
Abstract
The outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) threatens global medical systems and economies and rules our daily living life. Controlling the outbreak of SARS-CoV-2 has become one of the most important and urgent strategies throughout the whole world. As of October 2020, there have not yet been any medicines or therapies to be effective against SARS-CoV-2. Thus, rapid and sensitive diagnostics is the most important measures to control the outbreak of SARS-CoV-2. Homogeneous biosensing based on magnetic nanoparticles (MNPs) is one of the most promising approaches for rapid and highly sensitive detection of biomolecules. This paper proposes an approach for rapid and sensitive detection of SARS-CoV-2 with functionalized MNPs via the measurement of their magnetic response in an ac magnetic field. For proof of concept, mimic SARS-CoV-2 consisting of spike proteins and polystyrene beads are used for experiments. Experimental results demonstrate that the proposed approach allows the rapid detection of mimic SARS-CoV-2 with a limit of detection of 0.084 nM (5.9 fmole). The proposed approach has great potential for designing a low-cost and point-of-care device for rapid and sensitive diagnostics of SARS-CoV-2.
Collapse
Affiliation(s)
- Jing Zhong
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Enja Laureen Rösch
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Thilo Viereck
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Meinhard Schilling
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| | - Frank Ludwig
- Institute for Electrical Measurement Science and Fundamental Electrical
Engineering and Laboratory for Emerging Nanometrology (LENA), TU
Braunschweig, Hans-Sommer-Str. 66, Braunschweig D-38106,
Germany
| |
Collapse
|
25
|
Chen YH, Gupta NK, Huang HJ, Lam CH, Huang CL, Tan KT. Affinity-Switchable Lateral Flow Assay. Anal Chem 2021; 93:5556-5561. [DOI: 10.1021/acs.analchem.1c00138] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Yu-Hsuan Chen
- Department of Chemistry, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
| | - Nitesh K. Gupta
- Department of Chemistry, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
| | - Hsiao-Jung Huang
- Department of Chemistry, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
| | - Chak Hin Lam
- Department of Chemistry, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
| | - Ching-Lan Huang
- Department of Chemistry, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
| | - Kui-Thong Tan
- Department of Chemistry, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
- Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101 Section 2, Kuang Fu Road, Hsinchu 30013, Taiwan, Republic of China
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung 807, Taiwan, Republic of China
| |
Collapse
|
26
|
Lu H, Li M, Nilghaz A, Li L, Chen G, Jiang Y, Tian J. Paper-based analytical device for high-throughput monitoring tetracycline residue in milk. Food Chem 2021; 354:129548. [PMID: 33761333 DOI: 10.1016/j.foodchem.2021.129548] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 03/04/2021] [Accepted: 03/04/2021] [Indexed: 01/29/2023]
Abstract
A low-cost and portable paper-based analytical device has been developed for high throughput and on-site monitoring TC residue in milk through visualized colorimetric reaction. The filtration and concentration effect induced by the porous nature of paper contribute to strengthen the color intensity, leading to quantitative and sensitive detection of tetracycline reaching 1 ppm detection limit, with the linear range of 1-100 ppm both in water and milk samples. The applicability was demonstrated by detection of TC in 18 different types of real milk samples with good recovery ranging from 88% to 113%. Furthermore, the dynamic degradation behavior of tetracycline was monitored through the device. To the best of our knowledge, this is the first report of colorimetric detection of tetracycline in milk using the paper-based device. This simple, fast, cost-effective (~$0.50 per device) and equipment-free paper-based platform provides a promising tool for future application in food and environmental safety.
Collapse
Affiliation(s)
- Huimin Lu
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China
| | - Miaosi Li
- School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640, China; Guangzhou New Chemical Material Technology Ltd., Guangzhou 510640, China.
| | - Azadeh Nilghaz
- Institute for Frontier Materials, Deakin University, Waurn Ponds Campus, VIC 3216, Australia
| | - Lizi Li
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China
| | - Guangxue Chen
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China
| | - Yanbin Jiang
- School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640, China.
| | - Junfei Tian
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China.
| |
Collapse
|
27
|
Li G, Wang A, Chen Y, Sun Y, Du Y, Wang X, Ding P, Jia R, Wang Y, Zhang G. Development of a Colloidal Gold-Based Immunochromatographic Strip for Rapid Detection of Severe Acute Respiratory Syndrome Coronavirus 2 Spike Protein. Front Immunol 2021; 12:635677. [PMID: 33777026 PMCID: PMC7992422 DOI: 10.3389/fimmu.2021.635677] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 02/12/2021] [Indexed: 11/17/2022] Open
Abstract
The outbreak and worldwide pandemic of the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have a significant impact on global economy and human health. In order to reduce the disease spread, 16 monoclonal antibodies (McAbs) again SARS-CoV-2 were generated by immunized mice with the spike protein receptor binding domain (RBD), which was expressed in Chinese hamster ovary cell (CHO). A colloidal gold-based immunochromatographic strip was developed with two McAbs to detect SARS-CoV-2 spike protein, which can play a potential role in monitoring vaccine quality. The strip is highly specific, detecting only SARS-CoV-2 spike protein, and does not show any non-specific reactions with syndrome coronavirus (SARS-CoV), Middle East respiratory syndrome coronavirus (MERS-CoV) and other coronavirus and influenza viruses. The strip detected subunit vaccine in our laboratory with a detection limit of spike protein of 62.5 ng/mL. This strip provides an effective method in monitoring vaccine quality by detecting the antigen content of spike protein.
Collapse
Affiliation(s)
- Ge Li
- College of Veterinary Medicine, Henan Agricultural University, Zhengzhou, China.,School of Life Sciences, Zhengzhou University, Zhengzhou, China
| | - Aiping Wang
- School of Life Sciences, Zhengzhou University, Zhengzhou, China
| | - Yumei Chen
- School of Life Sciences, Zhengzhou University, Zhengzhou, China
| | - Yaning Sun
- Henan Zhongze Biological Engineering Co., Zhengzhou, China
| | - Yongkun Du
- College of Veterinary Medicine, Henan Agricultural University, Zhengzhou, China
| | - Xun Wang
- College of Veterinary Medicine, Henan Agricultural University, Zhengzhou, China
| | - Peiyang Ding
- School of Life Sciences, Zhengzhou University, Zhengzhou, China
| | - Rui Jia
- Henan Zhongze Biological Engineering Co., Zhengzhou, China
| | - Yanwei Wang
- Henan Zhongze Biological Engineering Co., Zhengzhou, China
| | - Gaiping Zhang
- College of Veterinary Medicine, Henan Agricultural University, Zhengzhou, China.,School of Life Sciences, Zhengzhou University, Zhengzhou, China
| |
Collapse
|
28
|
Li P, Lee GH, Kim SY, Kwon SY, Kim HR, Park S. From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices. ACS NANO 2021; 15:1960-2004. [PMID: 33534541 DOI: 10.1021/acsnano.0c06688] [Citation(s) in RCA: 138] [Impact Index Per Article: 34.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Patient-friendly medical diagnostics and treatments have been receiving a great deal of interest due to their rapid and cost-effective health care applications with minimized risk of infection, which has the potential to replace conventional hospital-based medical procedures. In particular, the integration of recently developed materials into health care devices allows the rapid development of point-of-care (POC) sensing platforms and implantable devices with special functionalities. In this review, the recent advances in biosensors for patient-friendly diagnosis and implantable devices for patient-friendly treatment are discussed. Comprehensive analysis of portable and wearable biosensing platforms for patient-friendly health monitoring and disease diagnosis is provided, including topics such as materials selection, device structure and integration, and biomarker detection strategies. Moreover, specific challenges related to each biological fluid for wearable biosensor-based POC applications are presented. Also, advances in implantable devices, including recent materials development and wireless communication strategies, are discussed. Furthermore, various patient-friendly surgical and treatment approaches are reviewed, such as minimally invasive insertion and mounting, in vivo electrical and optical modulations, and post-operation health monitoring. Finally, the challenges and future perspectives toward the development of the patient-friendly diagnosis and treatment are provided.
Collapse
Affiliation(s)
- Pei Li
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Gun-Hee Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Su Yeong Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Se Young Kwon
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Hyung-Ryong Kim
- College of Dentistry and Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan 330-714, Republic of Korea
| | - Steve Park
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| |
Collapse
|
29
|
Gürel-Gökmen B, Taslak HD, Özcan O, İpar N, Tunali-Akbay T. Polycaprolactone/silk fibroin electrospun nanofibers-based lateral flow test strip for quick and facile determination of bisphenol A in breast milk. J Biomed Mater Res B Appl Biomater 2021; 109:1455-1464. [PMID: 33501724 DOI: 10.1002/jbm.b.34805] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 12/13/2020] [Accepted: 01/09/2021] [Indexed: 01/06/2023]
Abstract
This study aimed to develop a sensitive lateral flow test strip for the detection of bisphenol A (BPA) in breast milk. Conventional nitrocellulose test membrane was coated with the coaxial nanofiber, consisting of the inner polycaprolactone (PCL) and the outer PCL/silk fibroin (SF) mixture, to decrease the flow rate of the breast milk in the lateral flow assay (LFA). The nanofiber was prepared by using coaxial electrospinning, and BPA antibody was immobilized physically to the nanofiber. This nanofiber was used as a test membrane in the LFA. Color changes on the test membrane were evaluated as the signal intensity of the BPA. Breast milk creates a background on surfaces due to its structural properties. This background was detected by comparing the signal intensity with the signal intensity of water. The higher signal intensity was found in water samples when compared to breast milk samples. Although the detection limit is 2 ng/ml in both coaxial PCL/SF nanofiber and nitrocellulose (NC) test membranes, the color intensity increased with the increasing BPA concentration in the coaxial PCL/SF nanofiber. As a new dimension, the coaxial PCL/SF nanofiber provided higher color intensity than the NC membrane. In conclusion, a sensitive onsite method was developed for the detection of BPA in breast milk by using new coaxial PCL/SF nanofiber as a test membrane in LFA.
Collapse
Affiliation(s)
- Begüm Gürel-Gökmen
- Faculty of Dentistry, Department of Biochemistry, Marmara University, İstanbul, Turkey
| | - Hava Dudu Taslak
- Faculty of Dentistry, Department of Biochemistry, Marmara University, İstanbul, Turkey
| | - Ozan Özcan
- Faculty of Dentistry, Department of Biochemistry, Marmara University, İstanbul, Turkey
| | - Necla İpar
- Department of Pediatrics, Koc University Hospital, İstanbul, Turkey
| | - Tuğba Tunali-Akbay
- Faculty of Dentistry, Department of Biochemistry, Marmara University, İstanbul, Turkey
| |
Collapse
|
30
|
A fully automated microfluidic PCR-array system for rapid detection of multiple respiratory tract infection pathogens. Anal Bioanal Chem 2021; 413:1787-1798. [PMID: 33492406 PMCID: PMC7829496 DOI: 10.1007/s00216-021-03171-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 12/31/2020] [Accepted: 01/07/2021] [Indexed: 12/17/2022]
Abstract
Rapid and accurate identification of respiratory tract infection pathogens is of utmost importance for clinical diagnosis and treatment, as well as prevention of pathogen transmission. To meet this demand, a microfluidic chip-based PCR-array system, Onestart, was developed. The Onestart system uses a microfluidic chip packaged with all the reagents required, and the waste liquid is also collected and stored on the chip. This ready-to-use system can complete the detection of 21 pathogens in a fully integrated manner, with sample lysis, nucleic acid extraction/purification, and real-time PCR sequentially implemented on the same chip. The entire analysis process is completed within 1.5 h, and the system automatically generates a test report. The lower limit-of-detection (LOD) of the Onestart assay was determined to be 1.0 × 103 copies·mL−1. The inter-batch variation of cycle threshold (Ct) values ranged from 0.08% to 0.69%, and the intra-batch variation ranged from 0.9% to 2.66%. Analytical results of the reference sample mix showed a 100% specificity of the Onestart assay. The analysis of batched clinical samples showed consistency of the Onestart assay with real-time PCR. With its ability to provide rapid, sensitive, and specific detection of respiratory tract infection pathogens, application of the Onestart system will facilitate timely clinical management of respiratory tract infections and effective prevention of pathogen transmission.
Collapse
|
31
|
Sachdeva S, Davis RW, Saha AK. Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions. Front Bioeng Biotechnol 2021; 8:602659. [PMID: 33520958 PMCID: PMC7843572 DOI: 10.3389/fbioe.2020.602659] [Citation(s) in RCA: 110] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 12/15/2020] [Indexed: 12/23/2022] Open
Abstract
Point-of-care testing (POCT) allows physicians to detect and diagnose diseases at or near the patient site, faster than conventional lab-based testing. The importance of POCT is considerably amplified in the trying times of the COVID-19 pandemic. Numerous point-of-care tests and diagnostic devices are available in the market including, but not limited to, glucose monitoring, pregnancy and infertility testing, infectious disease testing, cholesterol testing and cardiac markers. Integrating microfluidics in POCT allows fluid manipulation and detection in a singular device with minimal sample requirements. This review presents an overview of two technologies - (a.) Lateral Flow Assay (LFA) and (b.) Nucleic Acid Amplification - upon which a large chunk of microfluidic POCT diagnostics is based, some of their applications, and commercially available products. Apart from this, we also delve into other microfluidic-based diagnostics that currently dominate the in-vitro diagnostic (IVD) market, current testing landscape for COVID-19 and prospects of microfluidics in next generation diagnostics.
Collapse
Affiliation(s)
| | | | - Amit K. Saha
- Genome Technology Center, School of Medicine, Stanford University, Palo Alto, CA, United States
| |
Collapse
|
32
|
Kumar Y, Narsaiah K. Rapid point-of-care testing methods/devices for meat species identification: A review. Compr Rev Food Sci Food Saf 2020; 20:900-923. [PMID: 33443804 DOI: 10.1111/1541-4337.12674] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 08/30/2020] [Accepted: 10/25/2020] [Indexed: 12/15/2022]
Abstract
The authentication of animal species is an important issue due to an increasing trend of adulteration and mislabeling of animal species in processed meat products. Polymerase chain reaction is the most sensitive and specific technique for nucleic acid-based animal species detection. However, it is a time-consuming technique that requires costly thermocyclers and sophisticated labs. In recent times, there is a need of on-site detection by point-of-care (POC) testing methods and devices under low-resource settings. These POC devices must be affordable, sensitive, specific, user-friendly, rapid and robust, equipment free, and delivered to the end users. POC devices should also confirm the concept of micro total analysis system. This review discusses POC testing methods and devices that have been developed for meat species identification. Recent developments in lateral flow assay-based devices for the identification of animal species in meat products are also reviewed. Advancements in increasing the efficiency of lateral flow detection are also discussed.
Collapse
Affiliation(s)
- Yogesh Kumar
- Department of Agricultural Structures and Environmental Control, ICAR-Central Institute of Post-Harvest Engineering and Technology (CIPHET), Ludhiana, India
| | - Kairam Narsaiah
- Department of Agricultural Structures and Environmental Control, ICAR-Central Institute of Post-Harvest Engineering and Technology (CIPHET), Ludhiana, India
| |
Collapse
|
33
|
Wang X, Yang D, Jia ST, Zhao LL, Jia TT, Xue CH. Electrospun nitrocellulose membrane for immunochromatographic test strip with high sensitivity. Mikrochim Acta 2020; 187:644. [PMID: 33155110 DOI: 10.1007/s00604-020-04626-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 10/28/2020] [Indexed: 02/07/2023]
Abstract
The main goal of this work is to develop an economical, portable, disposable, and reliable point of care paper biosensor based on visualization, which can be used to detect viruses, bacteria, and proteins. However, the sensitivity of immunochromatography test (ICT) strips based on nitrocellulose to target detection has always been a problem. Here, we use an electrospun nitrocellulose (ENC) fiber membrane instead of traditional nitrocellulose fiber membrane to construct ICT strips for early pregnancy detection. By proper selection of the diameter of the ENC fiber to adjust the pore size, porosity, and morphology of the membrane, ICT strips with low flow rate and high protein loading were obtained. Based on these properties, a convenient and sensitive method for the colorimetric determination of human chorionic gonadotropin was developed. Under the optimal conditions, the detection limit of ICT based on ENC membrane is 10 mIU mL-1 (S/N = 3), the linear detection range is 5-1000 mIU mL-1, and the linear relationship is Y = 0.0434 X - 0.0136 (R2 = 0.9802). In addition, the test strip has good specificity and stability, and will not produce false-positive results. Graphical abstract.
Collapse
Affiliation(s)
- Xue Wang
- College of Environmental Science and Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China
| | - Dong Yang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China.
| | - Shun-Tian Jia
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China
| | - Ling-Ling Zhao
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China
| | - Tong-Tong Jia
- College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China
| | - Chao-Hua Xue
- College of Environmental Science and Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China. .,College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China.
| |
Collapse
|
34
|
Mahmoudi T, Shirdel B, Mansoori B, Baradaran B. Dual sensitivity enhancement in gold nanoparticle-based lateral flow immunoassay for visual detection of carcinoembryonic antigen. ANALYTICAL SCIENCE ADVANCES 2020; 1:161-172. [PMID: 38716129 PMCID: PMC10989072 DOI: 10.1002/ansa.202000023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 05/25/2020] [Accepted: 05/27/2020] [Indexed: 12/11/2022]
Abstract
In this work, we presented the development of cost-effective dual sensitivity enhancement in gold nanoparticle-based lateral flow test strip for detection of carcinoembryonic antigen. On the one hand, we employed protein G as a host matrix for oriented immobilization of antibodies within the nitrocellulose membrane. On the other hand, we utilized gold enhancement approach to visualize the final signals effectively. Primary examinations revealed that the smaller sized nanoparticles have greater signal enhancement compared to bigger ones. So, mono-dispersed gold nanoparticles with average diameters of 11.40 ± 1.40 nm were utilized as tags. The measurement of fluorescent intensity of FITC-tagged secondary antibody attached to the polyclonal antibody, in the presence/absence of protein G as a host matrix on microplate wells, showed the successful oriented immobilization of antibodies via the host matrix. The FESEM images confirmed the attachment and growth of nanoparticles within the porous nitrocellulose membrane, after gold enhancement. Finally, under the optimized conditions, the developed strip could quantify the standard values of target within 2-50 ng/mL range with a limit of detection of 0.35 ng/mL. This strategy enabled the reduction of antibody consumption from a conventional amount of 0.6 µg/strip down to 0.012 µg/strip. The serum samples containing carcinoembryonic antigen were also successfully analyzed by the developed strip with a visual detection limit of 10 ng/mL, which confirms favorable characteristics of the developed test strip for point-of-care applications.
Collapse
Affiliation(s)
- Tohid Mahmoudi
- Immunology Research CenterTabriz University of Medical SciencesTabrizIran
| | - Behnaz Shirdel
- Immunology Research CenterTabriz University of Medical SciencesTabrizIran
- Student Research CommitteeTabriz University of Medical SciencesTabrizIran
| | - Behzad Mansoori
- Immunology Research CenterTabriz University of Medical SciencesTabrizIran
- Department of Cancer and Inflammation ResearchInstitute of Molecular MedicineUniversity of Southern DenmarkOdenseDenmark
| | - Behzad Baradaran
- Immunology Research CenterTabriz University of Medical SciencesTabrizIran
| |
Collapse
|
35
|
Elgamouz A, Idriss H, Nassab C, Bihi A, Bajou K, Hasan K, Abu Haija M, Patole SP. Green Synthesis, Characterization, Antimicrobial, Anti-Cancer, and Optimization of Colorimetric Sensing of Hydrogen Peroxide of Algae Extract Capped Silver Nanoparticles. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1861. [PMID: 32957557 PMCID: PMC7557820 DOI: 10.3390/nano10091861] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 09/08/2020] [Accepted: 09/11/2020] [Indexed: 12/21/2022]
Abstract
A green and cost-effective technique for the preparation of silver nanoparticles (Algae-AgNPs) as a colorimetric sensor for hydrogen peroxide (H2O2) is described. Silver nanoparticles were capped using the green algae (Noctiluca scintillans) extract at an optimum time of 3 h at 80 °C. The pH of the plant extract (pH = 7.0) yields nanoparticles with a mean size of 4.13 nm and a zeta potential of 0.200 ± 0.02 mV and negative polarity, using dynamic light scattering (DLS). High-resolution transmission electron microscopy (HRTEM) analysis showed regular spherical particles with the average size of 4.5 nm. Selected area electron diffraction (SAED) results revealed the polycrystalline nature of the silver nanoparticles. The obtained patterns were indexed as (111), (200), (220), and (311) reflections of the fcc (face centered cubic) silver crystal based on their d-spacing of 2.47, 2.13, 1.49, and 1.27 Å, respectively. The apparent color change from brown to colorless was observed when nanoparticles reacted with H2O2. Linear responses were obtained in three different ranges (nM, µM, and mM). Limits of detection (LOD) of 1.33 ± 0.02 and 1.77 ± 0.02 nM and quantitation limits (LOQ) of 7.31 ± 0.03 and 9.67 ± 0.03 nM were obtained for Abs and ΔAbs calibration curves, respectively. 10% v/v Algae-AgNPs solution inhibited Staphylococcus aureus over Escherichia coli, while a 50% reduction of tumor cell growth of MDA-MB-231 human breast adenocarcinoma was obtained.
Collapse
Affiliation(s)
- Abdelaziz Elgamouz
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Hamid Idriss
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Chahlaa Nassab
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Alaa Bihi
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Khalid Bajou
- Department of Applied Biology, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE;
| | - Kamrul Hasan
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Mohammad Abu Haija
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi PO. Box 127788, UAE;
| | - Shashikant P. Patole
- Department of Physics, Khalifa University of Science and Technology, Abu Dhabi PO. Box 127788, UAE;
| |
Collapse
|
36
|
Rezaei Z, Mahmoudifard M. Pivotal role of electrospun nanofibers in microfluidic diagnostic systems - a review. J Mater Chem B 2020; 7:4602-4619. [PMID: 31364667 DOI: 10.1039/c9tb00682f] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Recently, the usage of electrospinning technology for the fabrication of fine fibers with a good deal of variation in morphology and structure has drawn the attention of many researchers around the world. These fibers have found their way in the many fields of science including medical diagnosis, tissue engineering, drug delivery, replica molding, solar cells, catalysts, energy conversion and storage, physical and chemical sensors and other applications. Among all applications, biosensing with the aim of rapid and sensitive biomarker detection is an area that warrants attention. Electrospun nanofibrous membranes enjoy numerous factors which benefit them to be used as potential candidates in biosensing platforms. Some of these factors include a high surface to volume ratio, analogous scale compared to bioactive molecules and relatively defect-free properties of nanofibers (NFs). In this review, we focused on the recent advances in electrospun nanofibrous membrane-based micro-analytical devices with an application as diagnostic systems. Hence, a study on the electrospun nanofiber usage in lab-on-a-chip and paper-based point-of-care devices, with an opening introduction to biosensors, nanofibers, the electrospinning method, and microfluidics as the principles of the intended subject, is provided. It is anticipated that the given examples in this paper will provide sufficient evidence for the potential of electrospun NFs for being used as a substrate in the commercial fabrication of highly sensitive and selective biosensors.
Collapse
Affiliation(s)
- Zahra Rezaei
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology, Tehran, Iran and Chemical & Petroleum Engineering Department, Sharif University of Technology, Tehran, Iran.
| | - Matin Mahmoudifard
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology, Tehran, Iran
| |
Collapse
|
37
|
Oprea M, Voicu SI. Recent advances in composites based on cellulose derivatives for biomedical applications. Carbohydr Polym 2020; 247:116683. [PMID: 32829811 DOI: 10.1016/j.carbpol.2020.116683] [Citation(s) in RCA: 117] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 06/21/2020] [Accepted: 06/22/2020] [Indexed: 01/17/2023]
Abstract
Cellulose derivatives represent a viable alternative to pure cellulose due to their solubility in water and common organic solvents. This, coupled with their low cost, biocompatibility, and biodegradability, makes them an attractive choice for applications related to the biomedicine and bioanalysis area. Cellulose derivatives-based composites with improved properties were researched as films and membranes for osseointegration, hemodialysis and biosensors, smart textile fibers, tissue engineering scaffolds, hydrogels and nanoparticles for drug delivery. The different preparation strategies of these polymeric composites as well as the most recent available experimental results were described in this review. General aspects such as structure and properties of cellulose extracted from plants or bacterial sources, types of cellulose derivatives and their synthesis methods were also discussed. Finally, the future perspectives related to composites based on cellulose derivatives were highlighted and some conclusions regarding the reviewed applications were drawn.
Collapse
Affiliation(s)
- Madalina Oprea
- National Institute for Research and Development in Chemistry and Petrochemistry - ICECHIM, Splaiul Independentei 202, 060021 Bucharest, Romania; Department of Analytical Chemistry and Environmental Engineering, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Stefan Ioan Voicu
- Department of Analytical Chemistry and Environmental Engineering, University Politehnica of Bucharest, 011061 Bucharest, Romania; Advanced Polymers Materials Group, University Politehnica of Bucharest, 011061 Bucharest, Romania.
| |
Collapse
|
38
|
Zhang Y, Liu X, Wang L, Yang H, Zhang X, Zhu C, Wang W, Yan L, Li B. Improvement in Detection Limit for Lateral Flow Assay of Biomacromolecules by Test-Zone Pre-enrichment. Sci Rep 2020; 10:9604. [PMID: 32541787 PMCID: PMC7295814 DOI: 10.1038/s41598-020-66456-1] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 05/18/2020] [Indexed: 12/26/2022] Open
Abstract
Lateral flow assay (LFA) is one of the most prevalent commercially available techniques for point-of-care tests due to its simplicity, celerity, low cost and robust operation. However, conventional colorimetric LFAs have inferior limits of detection (LODs) compared to sophisticated laboratory-based assays. Here, we report a simple strategy of test-zone pre-enrichment to improve the LOD of LFA by loading samples before the conjugate pad assembly. The developed method enables visual LODs of miR-210 mimic and human chorionic gonadotropin protein, to be improved by 10–100 fold compared with a conventional LFA setup without introducing any additional instrument and reagent except for phosphate running buffer, while no obvious difference occurred for Aflatoxin B1 (AFB1). It takes about 6–8 min to enrich every 50 μL of sample diluted with phosphate running buffer, therefore we can get visual results within 20 min. We identified a parameter by modeling the entire process, the concentration of probe-analyte conjugate at test zone when signaling unit being loaded, to be important for the improvement of visual limit of detection. In addition, the test-zone pre-enrichment did not impair the selectivity when miR-210 mimic was adopted as target. Integrated with other optimization, amplification and modification of LFAs, the developed test-zone pre-enrichment method can be applied to further improve LOD of LFAs.
Collapse
Affiliation(s)
- Yi Zhang
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China.
| | - Xiao Liu
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China
| | - Lingling Wang
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China
| | - Hanjie Yang
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China
| | - Xiaoxiao Zhang
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China
| | - Chenglong Zhu
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China
| | - Wenlong Wang
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Collaborative innovation center of food safety and quality control in Jiangsu Province, Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, PR China
| | - Lijing Yan
- Jiangnan University Hospital, Wuxi, 214122, PR China
| | - Bowei Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| |
Collapse
|
39
|
Abstract
Coronavirus disease 2019 (COVID-19) outbreak has become a global pandemic. The deleterious effects of coronavirus have prompted the development of diagnostic tools to manage the spread of disease. While conventional technologies such as quantitative real time polymerase chain reaction (qRT-PCR) have been broadly used to detect COVID-19, they are time-consuming, labor-intensive and are unavailable in remote settings. Point-of-care (POC) biosensors, including chip-based and paper-based biosensors are typically low-cost and user-friendly, which offer tremendous potential for rapid medical diagnosis. This mini review article discusses the recent advances in POC biosensors for COVID-19. First, the development of POC biosensors which are made of polydimethylsiloxane (PDMS), papers, and other flexible materials such as textile, film, and carbon nanosheets are reviewed. The advantages of each biosensors along with the commercially available COVID-19 biosensors are highlighted. Lastly, the existing challenges and future perspectives of developing robust POC biosensors to rapidly identify and manage the spread of COVID-19 are briefly discussed.
Collapse
Affiliation(s)
- Jane Ru Choi
- Centre for Blood Research, Life Sciences Centre, University of British Columbia, Vancouver, BC, Canada
- Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
40
|
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay. Biosens Bioelectron 2020; 152:112015. [PMID: 32056735 DOI: 10.1016/j.bios.2020.112015] [Citation(s) in RCA: 206] [Impact Index Per Article: 41.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 01/02/2020] [Accepted: 01/08/2020] [Indexed: 12/19/2022]
Abstract
Paper-based lateral-flow assays (LFAs) have achieved considerable commercial success and continue to have a significant impact on medical diagnostics and environmental monitoring. Conventional LFAs are typically performed by examining the color changes in the test bands by naked eye. However, for critical biochemical markers that are present in extremely small amounts in the clinical specimens, this readout method is not quantitative, and does not provide sufficient sensitivity or suitable detection limit for a reliable assay. Diverse technologies for high-sensitivity LFA detection have been developed and commercialization efforts are underway. In this review, we aim to provide a critical and objective overview of the recent progress in high-sensitivity LFA detection technologies, which involve the exploitation of the physical and chemical responses of transducing particles. The features and biomedical applications of the technologies, along with future prospects and challenges, are also discussed.
Collapse
|
41
|
Huang Y, Xu T, Wang W, Wen Y, Li K, Qian L, Zhang X, Liu G. Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments. Mikrochim Acta 2019; 187:70. [PMID: 31853644 DOI: 10.1007/s00604-019-3822-x] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 09/12/2019] [Indexed: 12/25/2022]
Abstract
This review (with 187 refs.) summarizes the progress that has been made in the design of lateral flow biosensors (LFBs) based on the use of micro- and nano-materials. Following a short introduction into the field, a first section covers features related to the design of LFBs, with subsections on strip-based, cotton thread-based and vertical flow- and syringe-based LFBs. The next chapter summarizes methods for sample pretreatment, from simple method to membrane-based methods, pretreatment by magnetic methods to device-integrated sample preparation. Advances in flow control are treated next, with subsections on cross-flow strategies, delayed and controlled release and various other strategies. Detection conditionst and mathematical modelling are briefly introduced in the following chapter. A further chapter covers methods for reliability improvement, for example by adding other validation lines or adopting different detection methods. Signal readouts are summarized next, with subsections on color-based, luminescent, smartphone-based and SERS-based methods. A concluding section summarizes the current status and addresses challenges in future perspectives. Graphical abstractRecent development and breakthrough points of lateral flow biosensors.
Collapse
Affiliation(s)
- Yan Huang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China.,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA
| | - Tailin Xu
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Wenqian Wang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Yongqiang Wen
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Kun Li
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China
| | - Lisheng Qian
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.
| | - Xueji Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China. .,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,School of Biomedical Engineering, Shenzhen University Healthy Science Center, Shenzhen, Guangdong, 518060, People's Republic of China.
| | - Guodong Liu
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA.
| |
Collapse
|
42
|
One-Step Polylactic Acid Screen-Printing Microfluidic Paper-Based Analytical Device: Application for Simultaneous Detection of Nitrite and Nitrate in Food Samples. CHEMOSENSORS 2019. [DOI: 10.3390/chemosensors7030044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
In this work, we report a one-step approach for fabricating screened-printed microfluidic paper-based analytical devices (μPADs) using polylactic acid as a new hydrophobic material. A polylactic acid solution was screen printed onto chromatography papers to create hydrophobic patterns for fluidic channels. The optimal polylactic acid concentration for successful device fabrication is 9% w/v. The μPADs were fabricated within 2 min and provided high reproducibility and stability. The utility of polylactic acid screen-printing was demonstrated for the simultaneous detection of nitrite and nitrate using colorimetric detection. Under optimized experimental conditions, the detection limits and the linear ranges, respectively, were 1.2 mg L−1 and 2–10 mg L−1 for nitrite and 3.6 mg L−1 and 10–50 mg L−1 for nitrate. The detection times for both ions were found to be within 12 min. The developed μPAD was applied for the simultaneous determination of these ions in food samples, and no significant differences in the analytical results were observed compared to those of the reference method. The polylactic acid screen-printing approach presented here provides a simple, rapid, and cost-effective alternative fabrication method for fabricating μPADs.
Collapse
|
43
|
Aliheidari N, Aliahmad N, Agarwal M, Dalir H. Electrospun Nanofibers for Label-Free Sensor Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E3587. [PMID: 31426538 PMCID: PMC6720643 DOI: 10.3390/s19163587] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/12/2019] [Accepted: 08/14/2019] [Indexed: 12/13/2022]
Abstract
Electrospinning is a simple, low-cost and versatile method for fabricating submicron and nano size fibers. Due to their large surface area, high aspect ratio and porous structure, electrospun nanofibers can be employed in wide range of applications. Biomedical, environmental, protective clothing and sensors are just few. The latter has attracted a great deal of attention, because for biosensor application, nanofibers have several advantages over traditional sensors, including a high surface-to-volume ratio and ease of functionalization. This review provides a short overview of several electrospun nanofibers applications, with an emphasis on biosensor applications. With respect to this area, focus is placed on label-free sensors, pertaining to both recent advances and fundamental research. Here, label-free sensor properties of sensitivity, selectivity, and detection are critically evaluated. Current challenges in this area and prospective future work is also discussed.
Collapse
Affiliation(s)
- Nahal Aliheidari
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA
| | - Nojan Aliahmad
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Mangilal Agarwal
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA.
- Purdue School of Engineering and Technology, Indiana University-Purdue University, Indianapolis, IN 46202, USA.
| | - Hamid Dalir
- Integrated Nanosystems Development Institute (INDI), Indiana University-Purdue University Indianapolis, Indianapolis, IN 46202, USA.
- Purdue School of Engineering and Technology, Indiana University-Purdue University, Indianapolis, IN 46202, USA.
| |
Collapse
|
44
|
Mahmoudi T, de la Guardia M, Shirdel B, Mokhtarzadeh A, Baradaran B. Recent advancements in structural improvements of lateral flow assays towards point-of-care testing. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.04.016] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
45
|
Electrospin-Coating of Paper: A Natural Extracellular Matrix Inspired Design of Scaffold. Polymers (Basel) 2019; 11:polym11040650. [PMID: 30970647 PMCID: PMC6523310 DOI: 10.3390/polym11040650] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 03/29/2019] [Accepted: 04/02/2019] [Indexed: 12/12/2022] Open
Abstract
Paper has recently found widespread applications in biomedical fields, especially as an alternative scaffolding material for cell cultures, owing to properties such as its fibrous nature, porosity and flexibility. However, paper on its own is not an optimal material for cell cultures as it lacks adhesion moieties specific to mammalian cells, and modifications such as hydrogel integration and chemical vapor deposition are necessary to make it a favorable scaffolding material. The present study focuses on modification of filter paper through electrospin-coating and dip-coating with polycaprolactone (PCL), a promising biomaterial in tissue engineering. Morphological analysis, evaluation of cell viability, alkaline phosphatase (ALP) activity and live/dead assays were conducted to study the potential of the modified paper-based scaffold. The results were compared to filter paper (FP) and electrospun PCL (ES-PCL) as reference samples. The results indicate that electrospin-coating paper is a simple and efficient way of modifying FP. It not only improves the morphology of the deposited electrospun layer through reduction of the fiber diameter by nearly 75%, but also greatly reduces the scaffold fabrication time compared to ES-PCL. The biochemical assays (Resazurin and ALP) indicate that electrospin-coated filter paper (ES-PCL/FP) provides significantly higher readings compared to all other groups. The live/dead results also show improved cell-distribution and cell-scaffold attachment all over the ES-PCL/FP.
Collapse
|
46
|
|
47
|
Choi JR, Yong KW, Choi JY, Cowie AC. Emerging Point-of-care Technologies for Food Safety Analysis. SENSORS (BASEL, SWITZERLAND) 2019; 19:817. [PMID: 30781554 PMCID: PMC6412947 DOI: 10.3390/s19040817] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 02/14/2019] [Accepted: 02/14/2019] [Indexed: 02/08/2023]
Abstract
Food safety issues have recently attracted public concern. The deleterious effects of compromised food safety on health have rendered food safety analysis an approach of paramount importance. While conventional techniques such as high-performance liquid chromatography and mass spectrometry have traditionally been utilized for the detection of food contaminants, they are relatively expensive, time-consuming and labor intensive, impeding their use for point-of-care (POC) applications. In addition, accessibility of these tests is limited in developing countries where food-related illnesses are prevalent. There is, therefore, an urgent need to develop simple and robust diagnostic POC devices. POC devices, including paper- and chip-based devices, are typically rapid, cost-effective and user-friendly, offering a tremendous potential for rapid food safety analysis at POC settings. Herein, we discuss the most recent advances in the development of emerging POC devices for food safety analysis. We first provide an overview of common food safety issues and the existing techniques for detecting food contaminants such as foodborne pathogens, chemicals, allergens, and toxins. The importance of rapid food safety analysis along with the beneficial use of miniaturized POC devices are subsequently reviewed. Finally, the existing challenges and future perspectives of developing the miniaturized POC devices for food safety monitoring are briefly discussed.
Collapse
Affiliation(s)
- Jane Ru Choi
- Department of Mechanical Engineering, University of British Columbia, 2054⁻6250 Applied Science Lane, Vancouver, BC V6T 1Z4, Canada.
- Centre for Blood Research, Life Sciences Centre, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada.
| | - Kar Wey Yong
- Department of Chemical & Petroleum Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
| | - Jean Yu Choi
- Faculty of Medicine, University of Dundee, Dow Street, Dundee DD1 5EH, UK.
| | - Alistair C Cowie
- Faculty of Medicine, University of Dundee, Dow Street, Dundee DD1 5EH, UK.
| |
Collapse
|
48
|
Liu Z, He X, Li A, Qu Z, Xu F. A two-dimensional mathematical model for analyzing the effects of capture probe properties on the performance of lateral flow assays. Analyst 2019; 144:5394-5403. [DOI: 10.1039/c9an00669a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Lateral flow assays (LFAs) are promising candidates in biomedical diagnosis fields due to their rapid, low-cost, and portable features.
Collapse
Affiliation(s)
- Zhi Liu
- Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education
- School of Energy and Power Engineering
- Xi'an Jiaotong University
- Xi'an 710049
- P.R. China
| | - Xiaocong He
- Bioinspired Engineering and Biomechanics Center (BEBC)
- Xi'an Jiaotong University
- Xi'an 710049
- P.R. China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research and Department of Periodontology
- College of Stomatology
- Xi'an Jiaotong University
- Xi'an 710004
- P.R. China
| | - Zhiguo Qu
- Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education
- School of Energy and Power Engineering
- Xi'an Jiaotong University
- Xi'an 710049
- P.R. China
| | - Feng Xu
- Bioinspired Engineering and Biomechanics Center (BEBC)
- Xi'an Jiaotong University
- Xi'an 710049
- P.R. China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education
| |
Collapse
|
49
|
Abstract
Paper has unique advantages over other materials, including low cost, flexibility, porosity, and self-driven liquid pumping, thus making it widely used in various fields in biology, chemistry, physics and materials science.
Collapse
Affiliation(s)
- Bingbing Gao
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Xin Li
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Yaqiong Yang
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Jianlin Chu
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| | - Bingfang He
- School of Pharmaceutical Sciences
- Nanjing Tech University
- Nanjing 211816
- China
| |
Collapse
|