1
|
Pringels L, Van Valckenborgh GJ, Segers P, Chevalier A, Stepman H, Wezenbeek E, Burssens A, Vanden Bossche L. Elevated fluid and glycosaminoglycan content in the Achilles tendon contribute to higher intratendinous pressures: Implications for Achilles tendinopathy. JOURNAL OF SPORT AND HEALTH SCIENCE 2024:S2095-2546(24)00048-6. [PMID: 38582138 DOI: 10.1016/j.jshs.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/17/2024] [Accepted: 02/29/2024] [Indexed: 04/08/2024]
Abstract
BACKGROUND Tendinopathy alters the compositional properties of the Achilles tendon by increasing fluid and glycosaminoglycan content. It has been speculated that these changes may affect intratendinous pressure, but the extent of this relationship remains unclear. Therefore, we aimed to investigate the impact of elevated fluid and glycosaminoglycan content on Achilles tendon intratendinous pressure and to determine whether hyaluronidase (HYAL) therapy can intervene in this potential relationship. METHODS Twenty paired fresh-frozen cadaveric Achilles tendons were mounted in a tensile-testing machine and loaded up to 5% strain. Intratendinous resting (at 0% strain) and dynamic pressure (at 5% strain) were assessed using the microcapillary infusion technique. First, intratendinous pressure was measured under native conditions before and after infusion of 2 mL physiological saline. Next, 80 mg of glycosaminoglycans were administered bilaterally to the paired tendons. The right tendons were additionally treated with 1500 units of HYAL. Finally, both groups were retested, and the glycosaminoglycan content was analyzed. RESULTS It was found that both elevated fluid and glycosaminoglycan content resulted in higher intratendinous resting and dynamic pressures (p < 0.001). HYAL treatment induced a 2.3-fold reduction in glycosaminoglycan content (p = 0.002) and restored intratendinous pressures. CONCLUSION The results of this study demonstrated that elevated fluid and glycosaminoglycan content in Achilles tendinopathy contribute to increased intratendinous resting and dynamic pressures, which can be explained by the associated increased volume and reduced permeability of the tendon matrix, respectively. HYAL degrades glycosaminoglycans sufficiently to lower intratendinous pressures and may, therefore, serve as a promising treatment.
Collapse
Affiliation(s)
- Lauren Pringels
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent 9000, Belgium; Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent 9000, Belgium.
| | | | - Patrick Segers
- Department of Electronics and Information Systems, Ghent University, Ghent 9000, Belgium
| | - Amélie Chevalier
- Department of Electromechanics, University of Antwerp, Antwerp 2020, Belgium
| | - Hedwig Stepman
- Department of Laboratory Medicine, Ghent University Hospital, Ghent 9000, Belgium
| | - Evi Wezenbeek
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent 9000, Belgium
| | - Arne Burssens
- Department of Orthopedic Surgery, Ghent University Hospital, Ghent 9000, Belgium
| | - Luc Vanden Bossche
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent 9000, Belgium; Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent 9000, Belgium
| |
Collapse
|
2
|
Huber S, Santschi MXT, Schadow J, Leunig M, Ferguson SJ. Structure, composition and anisotropic swelling of the bovine acetabular labrum. J Mech Behav Biomed Mater 2024; 150:106333. [PMID: 38134586 DOI: 10.1016/j.jmbbm.2023.106333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 12/14/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023]
Abstract
The fibro-cartilaginous labrum surrounds the acetabular rim and is important for hip joint stability and sealing. Sealing may be enhanced by swelling pressure within the normal labrum. Swelling of the degenerated or torn labrum might occur and potentially contribute to the development of osteoarthritis, through altered load transmission. This study aimed to characterize the three-dimensional swelling behaviour, the collagen fiber orientation and spatial proteoglycan distribution of the bovine acetabular labrum. Specimens were harvested from bovine donors (192-652 days, male, n = 6 donors). Structure was analyzed by scanning electron microscopy, histology, and dimethylmethylene blue assay. Specimen dimensions were measured before and after incubation in phosphate buffered saline to assess the swelling. Results showed that the articulating surface is composed of a collagen mesh network. Collagen fiber bundles showed a low degree of alignment close to the surface and were circumferentially aligned in the deep tissue. Proteoglycans were identified clustered between the collagen bundles. Glycosaminoglycan content was 10 x lower than that of cartilage (23.1 ± 6.4 compared to 299.5 ± 19.1 μg/mg dry weight) with minor regional differences. Specimens swelled significantly more in the orthogonal direction (swelling ratio 124.7 ± 10.2%) compared to the swelling parallel to the articulating surface (108.8 ± 6.1% and 102.8 ± 4.1%). In the deep tissue, swelling was also restricted in the main collagen fiber bundle direction (circumferentially), with a swelling ratio of 109.5 ± 4.0% in the main fiber bundle direction compared to 126.8 ± 7.3 % and 122.3 ± 5.8% radially. The findings demonstrate that the labrum shows anisotropic swelling properties, which reflect the anisotropy in the tissue structure and inter-fiber localisation of proteoglycans.
Collapse
Affiliation(s)
- Stephanie Huber
- ETH Zurich, Institute for Biomechanics, Zurich, Switzerland.
| | | | - Jemima Schadow
- ETH Zurich, Institute for Biomechanics, Zurich, Switzerland.
| | - Michael Leunig
- Schulthess Klinik, Department of Hip Surgery, Zurich, Switzerland.
| | | |
Collapse
|
3
|
Lake SP, Snedeker JG, Wang VM, Awad H, Screen HRC, Thomopoulos S. Guidelines for ex vivo mechanical testing of tendon. J Orthop Res 2023; 41:2105-2113. [PMID: 37312619 PMCID: PMC10528429 DOI: 10.1002/jor.25647] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 05/27/2023] [Accepted: 05/30/2023] [Indexed: 06/15/2023]
Abstract
Tendons are critical for the biomechanical function of joints. Tendons connect muscles to bones and allow for the transmission of muscle forces to facilitate joint motion. Therefore, characterizing the tensile mechanical properties of tendons is important for the assessment of functional tendon health and efficacy of treatments for acute and chronic injuries. In this guidelines paper, we review methodological considerations, testing protocols, and key outcome measures for mechanical testing of tendons. The goal of the paper is to present a simple set of guidelines to the nonexpert seeking to perform tendon mechanical tests. The suggested approaches provide rigorous and consistent methodologies for standardized biomechanical characterization of tendon and reporting requirements across laboratories.
Collapse
Affiliation(s)
- Spencer P. Lake
- Department of Mechanical Engineering & Materials Science, Washington University in St. Louis, St. Louis, Missouri, USA
| | | | - Vincent M. Wang
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, USA
| | - Hani Awad
- Department of Orthopaedics, Department of Biomedical Engineering, University of Rochester, Rochester, New York, USA
| | - Hazel R. C. Screen
- School of Engineering & Materials Science, Queen Mary University of London, London, UK
| | - Stavros Thomopoulos
- Department of Orthopaedic Surgery, Department of Biomedical Engineering, Columbia University, New York, New York, USA
| |
Collapse
|
4
|
Koo HB, Heo E, Cho I, Kim SH, Kang J, Chang JB. Human hand-inspired all-hydrogel gripper with a high load capacity formed by the split-brushing adhesion of diverse hydrogels. MATERIALS HORIZONS 2023; 10:2075-2085. [PMID: 36920793 DOI: 10.1039/d2mh01309f] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Human hands are highly versatile. Even though they are primarily made of materials with high water content, they exhibit a high load capacity. However, existing hydrogel grippers do not possess a high load capacity due to their innate softness and mechanical strength. This work demonstrates a human hand-inspired all-hydrogel gripper that can bear more than 47.6 times its own weight. This gripper is made of two hydrogels: poly(methacrylamide-co-methacrylic acid) (P(MAAm-co-MAAc)) and poly(N-isopropylacrylamide) (PNIPAM). P(MAAm-co-MAAc) is extremely stiff but becomes soft above its transition temperature. By taking advantage of the difference in the kinetics of the stiff-soft transition of P(MAAm-co-MAAc) hydrogels and the swelling-shrinking transition of PNIPAM hydrogels, this gripper can be switched between its stiff-bent and stiff-stretched states by simply changing the temperature. The assembly of these two hydrogels into a gripper necessitated the development of a new hydrogel adhesion method, as existing topological adhesion methods are not applicable to such stiff hydrogels. A new hydrogel adhesion method, termed split-brushing adhesion, has been demonstrated to satisfy this need. When applied to P(MAAm-co-MAAc) hydrogels, this method achieves an adhesion energy of 1221.6 J m-2, which is 67.5 times higher than that achieved with other topological adhesion methods.
Collapse
Affiliation(s)
- Hye Been Koo
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
| | - Eunseok Heo
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
| | - In Cho
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
| | - Sun Hong Kim
- Department of Electronic Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Jiheong Kang
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
| | - Jae-Byum Chang
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea.
| |
Collapse
|
5
|
Bi C, Thoreson AR, Zhao C. Improving Mechanical Properties of Tendon Allograft through Rehydration Strategies: An In Vitro Study. Bioengineering (Basel) 2023; 10:641. [PMID: 37370572 DOI: 10.3390/bioengineering10060641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/15/2023] [Accepted: 05/22/2023] [Indexed: 06/29/2023] Open
Abstract
Allogenic tendons grafts sourced from intrasynovial tendons are often used for tendon reconstruction. Processing is achieved through repetitive freeze-thaw cycles followed by lyophilization. Soaking the lyophilized tendon in saline (0.9%) for 24 h is the standard practice for rehydration. However, data supporting saline rehydration over the use of other hydrating solutions are scant. The purpose of the current study was to compare the effects of different rehydration solutions on biomechanical properties of lyophilized tendon allograft. A total of 36 canine flexor digitorum profundus tendons were collected, five freeze-thaw cycles followed by lyophilization were performed for processing, and then divided into three groups rehydrated with either saline solution (0.9%), phosphate-buffered saline (PBS), or minimum essential medium (MEM). Flexural stiffness, tensile stiffness, and gliding friction were evaluated before and after allograft processing. The flexural moduli in both fibrous and fibrocartilaginous regions of the tendons were measured. After lyophilization and reconstitution, the flexural moduli of both the fibrocartilaginous and non-fibrocartilaginous regions of the tendons increase significantly in the saline and MEM groups (p < 0.05). Compared to the saline and MEM groups, the flexural moduli of the fibrocartilaginous and non-fibrocartilaginous regions of tendons rehydrated with PBS are significantly lower (p < 0.05). Tensile moduli of rehydrated tendons are significantly lower than those of fresh tendons for all groups (p < 0.05). The gliding friction of rehydrated tendons is significantly higher than that of fresh tendons in all groups (p < 0.05). There is no significant difference in either tensile moduli or gliding friction between tendons treated with different rehydration solutions. These results demonstrate that allograft reconstitution can be optimized through careful selection of hydrating solution and that PBS could be a better choice as the impact on flexural properties is lower.
Collapse
Affiliation(s)
- Chun Bi
- Orthopedic Biomechanics Research Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
- Orthopaedic Traumatology, Trauma Center, Shanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, 650 Xin Songjiang Road, Shanghai 201620, China
| | - Andrew R Thoreson
- Materials and Structural Testing Core Laboratory, Mayo Clinic, 200 First ST SW, Rochester, MN 55905, USA
| | - Chunfeng Zhao
- Orthopedic Biomechanics Research Laboratory, Department of Orthopedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| |
Collapse
|
6
|
Jones CL, Penney BT, Theodossiou SK. Engineering Cell-ECM-Material Interactions for Musculoskeletal Regeneration. Bioengineering (Basel) 2023; 10:bioengineering10040453. [PMID: 37106640 PMCID: PMC10135874 DOI: 10.3390/bioengineering10040453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 03/23/2023] [Accepted: 03/28/2023] [Indexed: 04/29/2023] Open
Abstract
The extracellular microenvironment regulates many of the mechanical and biochemical cues that direct musculoskeletal development and are involved in musculoskeletal disease. The extracellular matrix (ECM) is a main component of this microenvironment. Tissue engineered approaches towards regenerating muscle, cartilage, tendon, and bone target the ECM because it supplies critical signals for regenerating musculoskeletal tissues. Engineered ECM-material scaffolds that mimic key mechanical and biochemical components of the ECM are of particular interest in musculoskeletal tissue engineering. Such materials are biocompatible, can be fabricated to have desirable mechanical and biochemical properties, and can be further chemically or genetically modified to support cell differentiation or halt degenerative disease progression. In this review, we survey how engineered approaches using natural and ECM-derived materials and scaffold systems can harness the unique characteristics of the ECM to support musculoskeletal tissue regeneration, with a focus on skeletal muscle, cartilage, tendon, and bone. We summarize the strengths of current approaches and look towards a future of materials and culture systems with engineered and highly tailored cell-ECM-material interactions to drive musculoskeletal tissue restoration. The works highlighted in this review strongly support the continued exploration of ECM and other engineered materials as tools to control cell fate and make large-scale musculoskeletal regeneration a reality.
Collapse
Affiliation(s)
- Calvin L Jones
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Dr MS2085, Boise, ID 83725, USA
| | - Brian T Penney
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Dr MS2085, Boise, ID 83725, USA
| | - Sophia K Theodossiou
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Dr MS2085, Boise, ID 83725, USA
| |
Collapse
|
7
|
Solis-Cordova J, Edwards JH, Fermor HL, Riches P, Brockett CL, Herbert A. Characterisation of native and decellularised porcine tendon under tension and compression: A closer look at glycosaminoglycan contribution to tendon mechanics. J Mech Behav Biomed Mater 2023; 139:105671. [PMID: 36682172 DOI: 10.1016/j.jmbbm.2023.105671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 11/17/2022] [Accepted: 01/07/2023] [Indexed: 01/13/2023]
Abstract
Decellularised porcine superflexor tendon (pSFT) has been characterised as a suitable scaffold for anterior cruciate ligament replacement, with dimensions similar to hamstring tendon autograft. However, decellularisation of tissues may reduce or damage extracellular matrix components, leading to undesirable biomechanical changes at a whole tissue scale. Although the role of collagen in tendons is well established, the mechanical contribution of glycosaminoglycans (GAGs) is less evident and could be altered by the decellularisation process. In this study, the contribution of GAGs to the tensile and compressive mechanical properties of pSFT was determined and whether decellularisation affected these properties by reducing GAG content or functionality. PSFTs were either enzymatically treated using chondroitinase ABC to remove GAGs or decellularised using previously established methods. Native, GAG-depleted and decellularised pSFT groups were then subjected to quantitative assays and biomechanical characterisation. In tension, specimens underwent stress relaxation and strength testing. In compression, specimens underwent confined compression testing. The GAG-depleted group was found to have circa 86% reduction of GAG content compared to native and decellularised groups. There was no significant difference in GAG content between native (3.75 ± 0.58 μg/mg) and decellularised (3.40 ± 0.37 μg/mg) groups. Stress relaxation testing discovered the time-independent and time-dependent relaxation moduli of the decellularised group were reduced ≥50% compared to native and GAG-depleted groups. However, viscoelastic behaviour of native and GAG-depleted groups resulted similar. Strength testing discovered no differences between native and GAG-depleted group's properties, albeit a reduction ∼20% for decellularised specimens' linear modulus and tensile strength compared to native tissue. In compression testing, the aggregate modulus was found to be circa 74% lower in the GAG-depleted group than the native and decellularised groups, while the zero-strain permeability was significantly higher in the GAG-depleted group (0.86 ± 0.65 mm4/N) than the decellularised group (0.03 ± 0.04 mm4/N). The results indicate that GAGs may significantly contribute to the mechanical properties of pSFT in compression, but not in tension. Furthermore, the content and function of GAGs in pSFTs are unaffected by decellularisation and the mechanical properties of the tissue remain comparable to native tissue.
Collapse
Affiliation(s)
- Jacqueline Solis-Cordova
- Institute of Medical and Biological Engineering, School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom; Institute of Medical and Biological Engineering, School of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Leeds, Leeds, United Kingdom.
| | - Jennifer H Edwards
- Institute of Medical and Biological Engineering, School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Hazel L Fermor
- Institute of Medical and Biological Engineering, School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Philip Riches
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Wolfson Centre, Glasgow, United Kingdom
| | - Claire L Brockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Leeds, Leeds, United Kingdom
| | - Anthony Herbert
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
8
|
Van Gulick L, Saby C, Jaisson S, Okwieka A, Gillery P, Dervin E, Morjani H, Beljebbar A. An integrated approach to investigate age-related modifications of morphological, mechanical and structural properties of type I collagen. Acta Biomater 2022; 137:64-78. [PMID: 34673231 DOI: 10.1016/j.actbio.2021.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 10/08/2021] [Accepted: 10/12/2021] [Indexed: 11/24/2022]
Abstract
The main propose of this study is to characterize the impact of chronological aging on mechanical, structural, biochemical, and morphological properties of type I collagen. We have developed an original approach combining a stress-strain measurement device with a portable Raman spectrometer to enable simultaneous measurement of Raman spectra during stress vs strain responses of young adult, adult and old rat tail tendon fascicles (RTTFs). Our data showed an increase in all mechanical properties such as Young's modulus, yield strength, and ultimate tensile strength with aging. At the molecular level, Raman data revealed that the most relevant frequency shift was observed at 938 cm-1 in Old RTTFs, which is assigned to the C-C. This suggested a long axis deformation of the peptide chains in Old RTTFs during tensile stress. In addition, the intensity of the band at 872 cm-1, corresponding to hydroxyproline decreased for young adult RTTFs and increased for the adult ones, while it remained unchanged for Old RTTFs during tensile stress. The amide III band (1242 and 1265 cm-1) as well as the band ratios I1631/ I1663 and I1645 / I1663 responses to tensile stress were depending on mechanical phases (toe, elastic and plastic). The quantification of advanced glycation end-products by LC-MS/MS and spectrofluorometry showed an increase in their content with aging. This suggested that the accumulation of such products was correlated to the alterations observed in the mechanical and molecular properties of RTTFs. Analysis of the morphological properties of RTTFs by SHG combined with CT-FIRE software revealed an increase in length and straightness of collagen fibers, whereas their width and wavy fraction decreased. Our integrated study model could be useful to provide additional translational information to monitor progression of diseases related to collagen remodeling in musculoskeletal disorders. STATEMENT OF SIGNIFICANCE: Type I collagen is the major component of the extracellular matrix. Its architectural and structural organization plays an important role in the mechanical properties of many tissues at the physiological and pathological levels. The objective of this work is to develop an integrated approach to bring a new insight on the impact of chronological aging on the structural organization and mechanical properties of type I collagen. We combined a portable Raman spectrometer with a mechanical tensile testing device in order to monitor in real time the changes in the Raman fingerprint of type I collagen fibers during the mechanical stress. Raman spectroscopy allowed the identification of the type I collagen bonds that were affected by mechanical stress in a differential manner with aging.
Collapse
|
9
|
Al Makhzoomi AK, Kirk TB, Dye DE, Allison GT. Contribution of glycosaminoglycans to the structural and mechanical properties of tendons - A multiscale study. J Biomech 2021; 128:110796. [PMID: 34649066 DOI: 10.1016/j.jbiomech.2021.110796] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 09/17/2021] [Accepted: 10/03/2021] [Indexed: 11/18/2022]
Abstract
Tendinopathy of the Achilles tendon contributes to a large range of disorders, including mechanical damage and degenerative diseases. Glycosaminoglycans (GAGs), are thought to play a role in the mechanical strength of tendons by forming cross-links between collagen molecules and allowing the transmission of forces between fibrils. This study assessed the response of GAG-depleted tendons to damage induced by fatigue loading, investigating the mechanical damage (stiffness, hysteresis and maximum load), macrostructural changes (tenocyte morphology, fiber anisotropy and waviness) assessed by confocal imaging and nanostructural changes (fibril D-periodicity length) within the same non-viable intact tendons. Changes in fiber waviness and tenocyte shape are strongly correlated to mechanical and nano-structural (D-periodicity elongation) properties in both Control and GAG-depleted tendons. This study supports firstly, the vital role GAGs play as mechanical connectors facilitating the load transfer between the fibrils and their hydrophilic role in facilitating fibril sliding. Secondly, that observed changes in tenocyte shape and fiber waviness correlate with tendon stiffness and other mechanical profiles.
Collapse
Affiliation(s)
- Anas K Al Makhzoomi
- School of Allied Health, Faculty of Health Science, Curtin University, Perth, Western Australia, Australia.
| | - Thomas B Kirk
- School of Science, Engineering and Technology, RMIT University Vietnam, Ho Chi Minh City, Vietnam
| | - Danielle E Dye
- Curtin Medical School, Faculty of Health Sciences, Curtin University, Perth, Western Australia, Australia
| | - Garry T Allison
- Research Office, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
10
|
Werbner B, Zhou M, McMindes N, Lee A, Lee M, O'Connell GD. Saline-polyethylene glycol blends preserve in vitro annulus fibrosus hydration and mechanics: An experimental and finite-element analysis. J Mech Behav Biomed Mater 2021; 125:104951. [PMID: 34749204 DOI: 10.1016/j.jmbbm.2021.104951] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 10/23/2021] [Accepted: 10/27/2021] [Indexed: 01/01/2023]
Abstract
Precise control of tissue water content is essential for ensuring accurate, repeatable, and physiologically relevant measurements of tissue mechanics and biochemical composition. While previous studies have found that saline and polyethylene glycol (PEG) blends were effective at controlling tendon and ligament hydration levels, this work has yet to be extended to the annulus fibrosus (AF). Thus, the first objective of this study was to determine and validate an optimal buffer solution for targeting and maintaining hydration levels of tissue-level AF specimens in vitro. This was accomplished by measuring the transient swelling behavior of bovine AF specimens in phosphate-buffered saline (PBS) and PEG buffers across a wide range of concentrations. Sub-failure, failure, and post-failure mechanics were measured to determine the relationship between changes in tissue hydration and tensile mechanical response. The effect of each buffer solution on tissue composition was also assessed. The second objective of this study was to assess the feasibility and effectiveness of using multi-phasic finite element models to investigate tissue swelling and mechanical responses in different external buffer solutions. A solution containing 6.25%w/v PBS and 6.25%w/v PEG effectively maintained tissue-level AF specimen hydration at fresh-frozen levels after 18 h in solution. Modulus, failure stress, failure strain, and post-failure toughness of specimens soaked in this solution for 18 h closely matched those of fresh-frozen specimens. In contrast, specimens soaked in 0.9%w/v PBS swelled over 100% after 18 h and exhibited significantly diminished sub-failure and failure properties compared to fresh-frozen controls. The increased cross-sectional area with swelling contributed to but was not sufficient to explain the diminished mechanics of PBS-soaked specimens, suggesting additional sub-tissue scale mechanisms. Computational simulations of these specimens generally agreed with experimental results, highlighting the feasibility and importance of including a fluid-phase description when models aim to provide accurate predictions of biological tissue responses. As numerous previous studies suggest that tissue hydration plays a central role in maintaining proper mechanical and biological function, robust methods for controlling hydration levels are essential as the field advances in probing the relationship between tissue hydration, aging, injury, and disease.
Collapse
Affiliation(s)
- Benjamin Werbner
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Minhao Zhou
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Nicole McMindes
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Allan Lee
- Department of Bioengineering, University of California, Berkeley, USA
| | - Matthew Lee
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Grace D O'Connell
- Department of Mechanical Engineering, University of California, Berkeley, USA; Department of Orthopaedic Surgery, University of California, San Francisco, USA.
| |
Collapse
|
11
|
Al Makhzoomi AK, Kirk TB, Allison GT. An AFM study of the nanostructural response of New Zealand white rabbit Achilles tendons to cyclic loading. Microsc Res Tech 2021; 85:728-737. [PMID: 34632676 DOI: 10.1002/jemt.23944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/14/2021] [Accepted: 09/09/2021] [Indexed: 01/21/2023]
Abstract
The nanostructural response of New Zealand white rabbit Achilles tendons to a fatigue damage model was assessed quantitatively and qualitatively using the endpoint of dose assessments of each tendon from our previous study. The change in mechanical properties was assessed concurrently with nanostructural change in the same non-viable intact tendon. Atomic force microscopy was used to study the elongation of D-periodicities, and the changes were compared both within the same fibril bundle and between fibril bundles. D-periodicities increased due to both increased strain and increasing numbers of fatigue cycles. Although no significant difference in D-periodicity lengthening was found between fibril bundles, the lengthening of D-periodicity correlated strongly with the overall tendon mechanical changes. The accurate quantification of fibril elongation in response to macroscopic applied strain assisted in assessing the complex structure-function relationship in Achilles tendons.
Collapse
Affiliation(s)
- Anas K Al Makhzoomi
- School of Allied Health, Faculty of Health Science, Curtin University, Perth, Western Australia, Australia
| | - Thomas B Kirk
- School of Science, Engineering and Technology, RMIT University Vietnam, Ho Chi Minh City, Vietnam
| | - Garry T Allison
- Associate Deputy Vice-Chancellor, Research Excellence, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
12
|
Al Makhzoomi AK, Kirk TB, Dye DE, Allison GT. The influence of glycosaminoglycan proteoglycan side chains on tensile force transmission and the nanostructural properties of Achilles tendons. Microsc Res Tech 2021; 85:233-243. [PMID: 34390286 DOI: 10.1002/jemt.23899] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 07/16/2021] [Accepted: 07/25/2021] [Indexed: 01/13/2023]
Abstract
This study investigates the nanostructural mechanisms that lie behind load transmission in tendons and the role of glycosaminoglycans (GAGs) in the transmission of force in the tendon extracellular matrix. The GAGs in white New Zealand rabbit Achilles tendons were enzymatically depleted, and the tendons subjected to cyclic loading at 6% strain for up to 2 hr. A nanoscale morphometric assessment of fibril deformation under strain was linked with the decline in the tendon macroscale mechanical properties. An atomic force microscope (AFM) was employed to characterize the D-periodicity within and between fibril bundles (WFB and BFB, respectively). By the end of the second hour of the applied strain, the WFB and BFB D-periodicities had significantly increased in the GAG-depleted group (29% increase compared with 15% for the control, p < .0001). No statistically significant differences were found between WFB and BFB D-periodicities in either the control or GAG-depleted groups, suggesting that mechanical load in Achilles tendons is uniformly distributed and fairly homogenous among the WFB and BFB networks. The results of this study have provided evidence of a cycle-dependent mechanism of damage accumulation. The accurate quantification of fibril elongation (measured as the WFB and BFB D-periodicity lengths) in response to macroscopic applied strain has assisted in assessing the complex structure-function relationship in Achilles tendon.
Collapse
Affiliation(s)
- Anas K Al Makhzoomi
- School of Allied Health, Faculty of Health Science, Curtin University, Perth, Western Australia, Australia
| | - Thomas B Kirk
- Dean, School of Science, Engineering and Technology, RMIT University Vietnam, Ho Chi Minh City, Vietnam
| | - Danielle E Dye
- Curtin Medical School, Faculty of Health Sciences, Curtin University, Perth, Western Australia, Australia
| | - Garry T Allison
- Associate Deputy Vice-Chancellor -Research Excellence - Curtin University, Perth, Western Australia, Australia, Member Board of Directors; Sports Medicine Australia, Perth
| |
Collapse
|
13
|
Hatami-Marbini H, Pachenari M. Tensile Viscoelastic Properties of the Sclera after Glycosaminoglycan Depletion. Curr Eye Res 2021; 46:1299-1308. [PMID: 34325593 DOI: 10.1080/02713683.2021.1874026] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE Fibrillar collagen network and glycosaminoglycans (GAGs) are the primary components of extracellular matrix (ECM) of the sclera. The main goal of this study was to investigate the possible structural roles of GAGs in the scleral tensile properties as a function of preconditioning and displacement rate. METHODS Four-step uniaxial stress-relaxation tests were used for characterizing the viscoelastic tensile response of the posterior porcine sclera with and without enzymatic GAG removal. The scleral strips were divided into different groups based on the displacement rate and the presence or absence of a preconditioning step in the loading protocol. The groups were (1) displacement rate of 0.2 mm/min without preconditioning, (2) displacement rate of 1 mm/min without preconditioning, (3) displacement rate of 0.2 mm/min with preconditioning, and (4) displacement rate of 1 mm/min with preconditioning. The peak stress, equilibrium stress, and the equilibrium elastic modulus were calculated for all specimens and compared against each other. RESULTS Increasing the displacement rate from 0.2 mm/min to 1.0 mm/min was found to cause an insignificant change in the equilibrium stress and equilibrium elastic modulus of porcine scleral strips. Removal of GAGs resulted in an overall stiffer tensile behavior independent of the displacement rate in samples that were not preconditioned (P < .05). The behavior of preconditioned samples with and without GAG removal was not significantly different from each other. CONCLUSIONS The experimental measurements of the present study showed that GAGs play an important role in the mechanical properties of the posterior porcine sclera. Furthermore, using a preconditioning step in the uniaxial testing protocol resulted in not being able to identify any significant difference in the tensile behavior of GAG depleted and normal scleral strips.
Collapse
Affiliation(s)
- Hamed Hatami-Marbini
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| | - Mohammad Pachenari
- Computational Biomechanics Research Laboratory, Mechanical and Industrial Engineering Department, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
14
|
Ekiert M, Karbowniczek J, Stachewicz U, Mlyniec A. The effect of multiple freeze-thaw cycles on the viscoelastic properties and microstructure of bovine superficial digital flexor tendon. J Mech Behav Biomed Mater 2021; 120:104582. [PMID: 34090220 DOI: 10.1016/j.jmbbm.2021.104582] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 04/15/2021] [Accepted: 05/08/2021] [Indexed: 11/19/2022]
Abstract
The most common injuries of the human musculoskeletal system are related to soft tissue structures such as tendons or ligaments. To repair torn structures, surgical intervention and application of a biological or synthetic graft may be required. A typical procedure for the processing, storage, and distribution of soft tissue grafts involves at least two freezing/thawing (F/T) cycles. Even though repeated F/T cycles decrease the mechanical performance and change the structure of tendons, it is unclear whether there exists a maximum number of F/T cycles above which tendons should not be approved for use as a tissue allograft. To fill this research gap, we present an ex vivo study on the effects of repetitive F/T cycles on the biomechanical stability of bovine superficial digital flexor tendon tissue. Using mechanical testing supported with scanning electron microscopy imaging, we show that multiple F/T cycles affect the viscoelastic and structural properties of tissue by significantly reducing its tensile modulus after the 3rd or 4th F/T cycle (depending on the strain range), stress drop during relaxation after the 8th F/T cycle (regardless the strain values), mechanical hysteresis after the 10th F/T cycle, and by causing a significant decrease in collagen fibril diameter. Our results provide a deeper insight into understanding the mechanisms responsible for tissue damage during multiple F/T cycles, and thus, may be useful for the future optimization of tissue storage protocols.
Collapse
Affiliation(s)
- Martyna Ekiert
- AGH University of Science and Technology, Faculty of Mechanics and Robotics, Krakow, Poland.
| | - Joanna Karbowniczek
- AGH University of Science and Technology, Faculty of Metals Engineering and Industrial Computer Science, Krakow, Poland
| | - Urszula Stachewicz
- AGH University of Science and Technology, Faculty of Metals Engineering and Industrial Computer Science, Krakow, Poland
| | - Andrzej Mlyniec
- AGH University of Science and Technology, Faculty of Mechanics and Robotics, Krakow, Poland
| |
Collapse
|
15
|
Ekiert M, Tomaszewski KA, Mlyniec A. The differences in viscoelastic properties of subtendons result from the anatomical tripartite structure of human Achilles tendon - ex vivo experimental study and modeling. Acta Biomater 2021; 125:138-153. [PMID: 33677161 DOI: 10.1016/j.actbio.2021.02.041] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 02/23/2021] [Accepted: 02/25/2021] [Indexed: 01/29/2023]
Abstract
The human Achilles tendon (AT) is a hierarchical structure macroscopically composed of three subtendons originating from the soleus (SOL) and gastrocnemius (GL, GM) muscles. According to recent reports, the divisible structure of the AT together with diverse material properties of its subtendons are suspected as a probable cause of non-homogeneous stress and strain distribution occurring in loaded AT. Despite numerous investigations on human AT, there is still relatively little knowledge regarding mechanical properties of subtendon-level hierarchy, which is crucial in fully understanding the multiscale relationship which governs tendon mechanics. In this paper we present the first ex vivo study conducted on SOL, GL, and GM subtendons of human AT. We investigate differences in viscoelastic properties of SOL, GM, and GL subtendons in terms of tensile modulus, mechanical hysteresis as well as stress relaxation observed at two different values of strain. Our results show that the most significant differences in mechanical properties exist between subtendon attached to the soleus muscle (SOL) and subtendons originating from the two heads of the gastrocnemius muscle (GM and GL). We used our experimental results to calibrate three different constitutive models: the hyperelastic Yeoh model with power-law flow, the microstructurally motivated Holzapfel-Gasser-Ogden model enhanced with strain-dependent Berström-Boyce flow and the phenomenological elasto-viscoplastic Arruda-Boyce-based model with strain-dependent Berström-Boyce flow supplemented with component representing matrix response. All calibrated models may be applied to commercial FEA software as a sufficient solution for rapid mechanical response modeling of human AT subtendons or for the purpose of future development of comprehensive patient-specific models of human lower limbs. STATEMENT OF SIGNIFICANCE: The divisible structure of the Achilles tendon together with diverse material properties of its subtendons are suspected as a probable cause of non-homogeneous stress and strain distribution occurring in loaded Achilles tendon. Despite numerous investigations on mechanical properties of Achilles tendon, there is still relatively little knowledge regarding mechanical properties of subtendon-level hierarchy, which is crucial in fully understanding the multiscale relationship which governs tendon mechanics. This study is the first reported ex vivo investigation conducted on SOL, GL, and GM human Achilles subtendons. We investigate differences in the viscoelastic properties of individual subtendons and demonstrate that the observed differences should be considered as muscle-dependent. Our experimental research is supported with a modeling study in which we calibrate three different constitutive models.
Collapse
Affiliation(s)
- Martyna Ekiert
- AGH University of Science and Technology, Faculty of Mechanical Engineering and Robotics, Mickiewicza 30 Av., Krakow 30-059, Poland.
| | - Krzysztof A Tomaszewski
- Andrzej Frycz Modrzewski Krakow University, Faculty of Medicine and Health Sciences, Gustawa Herlinga-Grudzinskiego 1, Krakow 30-705, Poland
| | - Andrzej Mlyniec
- AGH University of Science and Technology, Faculty of Mechanical Engineering and Robotics, Mickiewicza 30 Av., Krakow 30-059, Poland
| |
Collapse
|
16
|
Godinho MS, Thorpe CT, Greenwald SE, Screen HR. Elastase treatment of tendon specifically impacts the mechanical properties of the interfascicular matrix. Acta Biomater 2021; 123:187-196. [PMID: 33508509 PMCID: PMC7935645 DOI: 10.1016/j.actbio.2021.01.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 01/15/2021] [Accepted: 01/19/2021] [Indexed: 12/16/2022]
Abstract
The tendon interfascicular matrix (IFM) binds tendon fascicles together. As a result of its low stiffness behaviour under small loads, it enables non-uniform loading and increased overall extensibility of tendon by facilitating fascicle sliding. This function is particularly important in energy storing tendons, with previous studies demonstrating enhanced extensibility, recovery and fatigue resistance in the IFM of energy storing compared to positional tendons. However, the compositional specialisations within the IFM that confer this behaviour remain to be elucidated. It is well established that the IFM is rich in elastin, therefore we sought to test the hypothesis that elastin depletion (following elastase treatment) will significantly impact IFM, but not fascicle, mechanical properties, reducing IFM resilience in all samples, but to a greater extent in younger tendons, which have a higher elastin content. Using a combination of quasi-static and fatigue testing, and optical imaging, we confirmed our hypothesis, demonstrating that elastin depletion resulted in significant decreases in IFM viscoelasticity, fatigue resistance and recoverability compared to untreated samples, with no significant changes to fascicle mechanics. Ageing had little effect on fascicle or IFM response to elastase treatment. This study offers a first insight into the functional importance of elastin in regional specific tendon mechanics. It highlights the important contribution of elastin to IFM mechanical properties, demonstrating that maintenance of a functional elastin network within the IFM is essential to maintain IFM and thus tendon integrity. Statement of significance Developing effective treatments or preventative measures for musculoskeletal tissue injuries necessitates the understanding of healthy tissue function and mechanics. By establishing the contribution of specific proteins to tissue mechanical behaviour, key targets for therapeutics can be identified. Tendon injury is increasingly prevalent and chronically debilitating, with no effective treatments available. Here, we investigate how elastin modulates tendon mechanical behaviour, using enzymatic digestion combined with local mechanical characterisation, and demonstrate for the first time that removing elastin from tendon affects the mechanical properties of the interfascicular matrix specifically, resulting in decreased recoverability and fatigue resistance. These findings provide a new level of insight into tendon hierarchical mechanics, important for directing development of novel therapeutics for tendon injury.
Collapse
|
17
|
Bloom ET, Lee AH, Elliott DM. Tendon Multiscale Structure, Mechanics, and Damage Are Affected by Osmolarity of Bath Solution. Ann Biomed Eng 2021; 49:1058-1068. [PMID: 33128181 PMCID: PMC7954897 DOI: 10.1007/s10439-020-02649-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 10/03/2020] [Indexed: 11/29/2022]
Abstract
One of the most common bath solutions used in musculoskeletal mechanical testing is phosphate buffered saline (PBS). In tendon, swelling induced by physiological PBS results in decreased tendon modulus and induces microstructural changes. It is critical to evaluate the multiscale mechanical behavior of tendon under swelling to interpret prior work and provide information to design future studies. We compared the effects of physiological PBS and 8% polyethylene glycol and saline bathing solutions on tendon multiscale tendon mechanics and damage as well as microstructure with TEM in order to understand the effect of swelling on tendon. At the tissue level, tendons in PBS had a lower modulus than SPEG samples. PBS samples also showed an increased amount of non-recoverable sliding, which is an analog for microscale damage. SPEG had a higher microscale to tissue-scale strain ratio, showing the fibrils experienced less strain attenuation. From the TEM data, we showed the fibril spacing of SPEG samples was more similar to fresh control than PBS. We concluded that swelling alters multiscale mechanics and damage in addition to tendon microstructure. Future mechanical testing should consider using SPEG as a bath solution with an osmotic pressure which preserves fresh tissue water content.
Collapse
Affiliation(s)
- Ellen T Bloom
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE, 19716, USA
| | - Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE, 19716, USA
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE, 19716, USA.
| |
Collapse
|
18
|
Ristaniemi A, Regmi D, Mondal D, Torniainen J, Tanska P, Stenroth L, Finnilä MAJ, Töyräs J, Korhonen RK. Structure, composition and fibril-reinforced poroviscoelastic properties of bovine knee ligaments and patellar tendon. J R Soc Interface 2021; 18:20200737. [PMID: 33499766 DOI: 10.1098/rsif.2020.0737] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Tissue-level stress-relaxation of ligaments and tendons in the toe region is characterized by fast and long-term relaxations and an increase in relaxation magnitude with strain. Characterizing the compositional and structural origins of these phenomena helps in the understanding of mechanisms of ligament and tendon function and adaptation in health and disease. A three-step tensile stress-relaxation test was conducted on dumbbell-shaped pieces of bovine knee ligaments and patellar tendon (PT) (n = 10 knees). Their mechanical behaviour was characterized by a fibril-reinforced poroviscoelastic material model, able to describe characteristic times and magnitudes of fast and long-term relaxations. The crimp angle and length of tissues were measured with polarized light microscopy, while biochemical contents were determined by colorimetric biochemical methods. The long-term relaxation time was longer in the anterior cruciate ligament (ACL) and PT compared with collateral ligaments (p < 0.05). High hydroxyproline content predicted greater magnitude and shorter time of both fast and long-term relaxation. High uronic acid content predicted longer time of long-term relaxation, whereas high crimp angle predicted higher magnitude of long-term relaxation. ACL and PT are better long-term stabilizers than collateral ligaments. The long-term relaxation behaviour is affected or implied by proteoglycans and crimp angle, possibly relating to slow structural reorganization of the tissue.
Collapse
Affiliation(s)
- Aapo Ristaniemi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Dristi Regmi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Diponkor Mondal
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - Jari Torniainen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.,Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Lauri Stenroth
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Mikko A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - Juha Töyräs
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.,Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.,School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
19
|
Zhou M, Werbner B, O'Connell GD. Fiber engagement accounts for geometry-dependent annulus fibrosus mechanics: A multiscale, Structure-Based Finite Element Study. J Mech Behav Biomed Mater 2020; 115:104292. [PMID: 33453608 DOI: 10.1016/j.jmbbm.2020.104292] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 12/10/2020] [Accepted: 12/21/2020] [Indexed: 02/04/2023]
Abstract
A comprehensive understanding of biological tissue mechanics is crucial for designing engineered tissues that aim to recapitulate native tissue behavior. Tensile mechanics of many fiber-reinforced tissues have been shown to depend on specimen geometry, which makes it challenging to compare data between studies. In this study, a validated multiscale, structure-based finite element model was used to evaluate the effect of specimen geometry on multiscale annulus fibrosus tensile mechanics through a fiber engagement analysis. The relationships between specimen geometry and modulus, Poisson's ratio, tissue stress-strain distributions, and fiber reorientation behaviors were investigated at both tissue and sub-tissue levels. It was observed that annulus fibrosus tissue level tensile properties and stress transmission mechanisms were dependent on specimen geometry. The model also demonstrated that the contribution of fiber-matrix interactions to tissue mechanical response was specimen size- and orientation-dependent. The results of this study reinforce the benefits of structure-based finite element modeling in studies investigating multiscale tissue mechanics. This approach also provides guidelines for developing optimal combined computational-experimental study designs for investigating fiber-reinforced biological tissue mechanics. Additionally, findings from this study help explain the geometry dependence of annulus fibrosus tensile mechanics previously reported in the literature, providing a more fundamental and comprehensive understanding of tissue mechanical behavior. In conclusion, the methods presented here can be used in conjunction with experimental tissue level data to simultaneously investigate tissue and sub-tissue scale mechanics, which is important as the field of soft tissue biomechanics advances toward studies that focus on diminishing length scales.
Collapse
Affiliation(s)
- Minhao Zhou
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Benjamin Werbner
- Department of Mechanical Engineering, University of California, Berkeley, USA
| | - Grace D O'Connell
- Department of Mechanical Engineering, University of California, Berkeley, USA; Department of Orthopaedic Surgery, University of California, San Francisco, USA.
| |
Collapse
|
20
|
Safa BN, Bloom ET, Lee AH, Santare MH, Elliott DM. Evaluation of transverse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling. J Biomech 2020; 109:109892. [PMID: 32807341 DOI: 10.1016/j.jbiomech.2020.109892] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 05/15/2020] [Accepted: 06/09/2020] [Indexed: 12/14/2022]
Abstract
Tendon's viscoelastic behaviors are important to the tissue mechanical function and cellular mechanobiology. When loaded in longitudinal tension, tendons often have a large Poisson's ratio (ν>2) that exceeds the limit of incompressibility for isotropic material (ν=0.5), indicating that tendon experiences volume loss, inducing poroelastic fluid exudation in the transverse direction. Therefore, transverse poroelasticity is an important contributor to tendon material behavior. Tendon hydraulic permeability which is required to evaluate the fluid flow contribution to viscoelasticity, is mostly unavailable, and where available, varies by several orders of magnitude. In this manuscript, we quantified the transverse poroelastic material parameters of rat tail tendon fascicles by conducting transverse osmotic loading experiments, in both tension and compression. We used a multi-start optimization method to evaluate the parameters using biphasic finite element modeling. Our tendon samples had a transverse hydraulic permeability of 10-4 to 10-5 mm4. (Ns)-1 and showed a significant tension-compression nonlinearity in the transverse direction. Further, using these results, we predict hydraulic permeability during longitudinal (fiber-aligned) tensile loading, and the spatial distribution of fluid flow during osmotic loading. These results reveal novel aspects of tendon mechanics and can be used to study the physiomechanical response of tendon in response to mechanical loading.
Collapse
Affiliation(s)
- Babak N Safa
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Ellen T Bloom
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| |
Collapse
|
21
|
Ristaniemi A, Torniainen J, Stenroth L, Finnilä M, Paakkonen T, Töyräs J, Korhonen R. Comparison of water, hydroxyproline, uronic acid and elastin contents of bovine knee ligaments and patellar tendon and their relationships with biomechanical properties. J Mech Behav Biomed Mater 2020; 104:103639. [DOI: 10.1016/j.jmbbm.2020.103639] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 01/13/2020] [Accepted: 01/13/2020] [Indexed: 12/13/2022]
|
22
|
Denes BJ, Ait-Lounis A, Wehrle-Haller B, Kiliaridis S. Core Matrisome Protein Signature During Periodontal Ligament Maturation From Pre-occlusal Eruption to Occlusal Function. Front Physiol 2020; 11:174. [PMID: 32194440 PMCID: PMC7066325 DOI: 10.3389/fphys.2020.00174] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Accepted: 02/13/2020] [Indexed: 12/14/2022] Open
Abstract
The pre-occlusal eruption brings the molars into functional occlusion and initiates tensional strains during mastication. We hypothesized that upon establishment of occlusal contact, the periodontal ligament (PDL) undergoes cell and extracellular matrix maturation to adapt to this mechanical function. The PDL of 12 Wistar male rats were laser microdissected to observe the proteomic changes between stages of pre-occlusal eruption, initial occlusal contact and 1-week after occlusion. The proteome was screened by mass spectrometry and confirmed by immunofluorescence. The PDL underwent maturation upon establishment of occlusion. Downregulation of alpha-fetoprotein stem cell marker and protein synthesis markers indicate cell differentiation. Upregulated proteins were components of the extracellular matrix (ECM) and were characterized with the matrisome project database. In particular, periostin, a major protein of the PDL, was induced following occlusal contact and localized around collagen α-1 (III) bundles. This co-localization coincided with organization of collagen fibers in direction of the occlusal forces. Establishment of occlusion coincides with cellular differentiation and the maturation of the PDL. Co-localization of periostin and collagen with subsequent fiber organization may help counteract tensional forces and reinforce the ECM structure. This may be a key mechanism of the PDL to adapt to occlusal forces and maintain structural integrity.
Collapse
Affiliation(s)
- Balazs Jozsef Denes
- Department of Orthodontics, Clinique Universitaire de Médecine Dentaire, University of Geneva, Geneva, Switzerland
| | - Aouatef Ait-Lounis
- Department of Orthodontics, Clinique Universitaire de Médecine Dentaire, University of Geneva, Geneva, Switzerland.,Department of Cell Physiology and Metabolism, Centre Médical Universitaire, University of Geneva, Geneva, Switzerland
| | - Bernhard Wehrle-Haller
- Department of Cell Physiology and Metabolism, Centre Médical Universitaire, University of Geneva, Geneva, Switzerland
| | - Stavros Kiliaridis
- Department of Orthodontics, Clinique Universitaire de Médecine Dentaire, University of Geneva, Geneva, Switzerland
| |
Collapse
|
23
|
Kazaili A, Geraghty B, Akhtar R. Microscale assessment of corneal viscoelastic properties under physiological pressures. J Mech Behav Biomed Mater 2019; 100:103375. [DOI: 10.1016/j.jmbbm.2019.103375] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Revised: 07/21/2019] [Accepted: 07/26/2019] [Indexed: 10/26/2022]
|
24
|
Safa BN, Peloquin JM, Natriello JR, Caplan JL, Elliott DM. Helical fibrillar microstructure of tendon using serial block-face scanning electron microscopy and a mechanical model for interfibrillar load transfer. J R Soc Interface 2019; 16:20190547. [PMID: 31744419 DOI: 10.1098/rsif.2019.0547] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Tendon's hierarchical structure allows for load transfer between its fibrillar elements at multiple length scales. Tendon microstructure is particularly important, because it includes the cells and their surrounding collagen fibrils, where mechanical interactions can have potentially important physiological and pathological contributions. However, the three-dimensional (3D) microstructure and the mechanisms of load transfer in that length scale are not known. It has been postulated that interfibrillar matrix shear or direct load transfer via the fusion/branching of small fibrils are responsible for load transfer, but the significance of these mechanisms is still unclear. Alternatively, the helical fibrils that occur at the microstructural scale in tendon may also mediate load transfer; however, these structures are not well studied due to the lack of a three-dimensional visualization of tendon microstructure. In this study, we used serial block-face scanning electron microscopy to investigate the 3D microstructure of fibrils in rat tail tendon. We found that tendon fibrils have a complex architecture with many helically wrapped fibrils. We studied the mechanical implications of these helical structures using finite-element modelling and found that frictional contact between helical fibrils can induce load transfer even in the absence of matrix bonding or fibril fusion/branching. This study is significant in that it provides a three-dimensional view of the tendon microstructure and suggests friction between helically wrapped fibrils as a mechanism for load transfer, which is an important aspect of tendon biomechanics.
Collapse
Affiliation(s)
- Babak N Safa
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.,Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - John M Peloquin
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Jessica R Natriello
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Jeffrey L Caplan
- Department of Plant and Soil Sciences, University of Delaware, Newark, DE, USA.,Delaware Biotechnology Institute, University of Delaware, Newark, DE, USA
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| |
Collapse
|
25
|
Decellularisation affects the strain rate dependent and dynamic mechanical properties of a xenogeneic tendon intended for anterior cruciate ligament replacement. J Mech Behav Biomed Mater 2019; 91:18-23. [DOI: 10.1016/j.jmbbm.2018.11.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 11/02/2018] [Accepted: 11/23/2018] [Indexed: 01/20/2023]
|
26
|
GAG content, fiber stiffness, and fiber angle affect swelling-based residual stress in the intact annulus fibrosus. Biomech Model Mechanobiol 2018; 18:617-630. [DOI: 10.1007/s10237-018-1105-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 11/29/2018] [Indexed: 12/16/2022]
|
27
|
Liu R, Becer CR, Screen HRC. Guided Cell Attachment via Aligned Electrospinning of Glycopolymers. Macromol Biosci 2018; 18:e1800293. [DOI: 10.1002/mabi.201800293] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 09/17/2018] [Indexed: 12/24/2022]
Affiliation(s)
- Renjie Liu
- Polymer Chemistry LaboratorySchool of Engineering and Materials ScienceQueen Mary University of London E1 4NS London UK
| | - Caglar Remzi Becer
- Polymer Chemistry LaboratorySchool of Engineering and Materials ScienceQueen Mary University of London E1 4NS London UK
| | - Hazel R. C. Screen
- Institute of BioengineeringSchool of Engineering and Materials ScienceQueen Mary University of London E1 4NS London UK
| |
Collapse
|
28
|
Yang B, O'Connell GD. Swelling of fiber-reinforced soft tissues is affected by fiber orientation, fiber stiffness, and lamella structure. J Mech Behav Biomed Mater 2018; 82:320-328. [PMID: 29653381 DOI: 10.1016/j.jmbbm.2018.03.039] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 03/13/2018] [Accepted: 03/29/2018] [Indexed: 01/13/2023]
Abstract
Native and engineered fiber-reinforced tissues are composites comprised of stiff collagen fibers embedded within an extrafibrillar matrix that is capable of swelling by absorbing water molecules. Tissue swelling is important for understanding stress distributions between collagen fibers and extrafibrillar matrix, as well as for understanding mechanisms of tissue failure. The swelling behavior of fiber-reinforced tissues in the musculoskeletal system has been largely attributed to the glycosaminoglycan content. Recent work demonstrated anisotropy in the swelling response of the annulus fibrosus in the intervertebral disc. It is well known that collagen fiber orientation affects elastic behavior, but the effect of collagen fiber network on tissue swelling behavior is not well understood. In this study, we developed three series of models to evaluate the effect of collagen fiber orientation, fiber network architecture (i.e., single or multi-fiber families within a layer), and fiber stiffness on bulk tissue swelling, which was simulated by describing the extrafibrillar matrix as a triphasic material, as proposed by Lai et al. Model results were within one standard deviation of reported mean values for changes in tissue volume, width, and thickness under free swelling conditions. The predicted swelling response of single-fiber family structures was highly dependent on fiber orientation and the number of lamellae in the bulk tissue. Moreover, matrix swelling resulted in tissue to twist, which reduced fiber deformations, demonstrating a balance between fiber deformation and matrix swelling. Large changes in fiber stiffness (20 × increase) had a relatively small effect on tissue swelling (~ 2% decrease in swelling). In conclusion, fiber angle, fiber architecture (defined as single- versus multiple fiber families in a layer), and the number of layers in a single fiber family structure directly affected tissue swelling behavior, including fiber stretch, fiber reorientation, and tissue deformation. These findings support the need to develop computational models that closely mimic the native architecture in order to understand mechanisms of stress distributions and tissue failure.
Collapse
Affiliation(s)
- Bo Yang
- Department of Mechanical Engineering, University of California, Berkeley, United States
| | - Grace D O'Connell
- Department of Mechanical Engineering, University of California, Berkeley, United States; Department of Orthopaedic Surgery, University of California, San Francisco, United States.
| |
Collapse
|
29
|
Nagy N, de la Zerda A, Kaber G, Johnson PY, Hu KH, Kratochvil MJ, Yadava K, Zhao W, Cui Y, Navarro G, Annes JP, Wight TN, Heilshorn SC, Bollyky PL, Butte MJ. Hyaluronan content governs tissue stiffness in pancreatic islet inflammation. J Biol Chem 2017; 293:567-578. [PMID: 29183997 DOI: 10.1074/jbc.ra117.000148] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/10/2017] [Indexed: 12/14/2022] Open
Abstract
We have identified a novel role for hyaluronan (HA), an extracellular matrix polymer, in governing the mechanical properties of inflamed tissues. We recently reported that insulitis in type 1 diabetes of mice and humans is preceded by intraislet accumulation of HA, a highly hygroscopic polymer. Using the double transgenic DO11.10 × RIPmOVA (DORmO) mouse model of type 1 diabetes, we asked whether autoimmune insulitis was associated with changes in the stiffness of islets. To measure islet stiffness, we used atomic force microscopy (AFM) and developed a novel "bed of nails"-like approach that uses quartz glass nanopillars to anchor islets, solving a long-standing problem of keeping tissue-scale objects immobilized while performing AFM. We measured stiffness via AFM nanoindentation with a spherical indenter and found that insulitis made islets mechanically soft compared with controls. Conversely, treatment with 4-methylumbelliferone, a small-molecule inhibitor of HA synthesis, reduced HA accumulation, diminished swelling, and restored basal tissue stiffness. These results indicate that HA content governs the mechanical properties of islets. In hydrogels with variable HA content, we confirmed that increased HA leads to mechanically softer hydrogels, consistent with our model. In light of recent reports that the insulin production of islets is mechanosensitive, these findings open up an exciting new avenue of research into the fundamental mechanisms by which inflammation impacts local cellular responses.
Collapse
Affiliation(s)
- Nadine Nagy
- From the Department of Medicine, Division of Infectious Diseases,
| | | | - Gernot Kaber
- From the Department of Medicine, Division of Infectious Diseases
| | - Pamela Y Johnson
- the Matrix Biology Program, Benaroya Research Institute, Seattle, Washington 98101
| | | | - Michael J Kratochvil
- From the Department of Medicine, Division of Infectious Diseases.,the Department of Materials Science and Engineering
| | - Koshika Yadava
- From the Department of Medicine, Division of Infectious Diseases
| | - Wenting Zhao
- the Department of Materials Science and Engineering
| | - Yi Cui
- the Department of Materials Science and Engineering
| | | | - Justin P Annes
- the Department of Medicine, Division of Endocrinology, and
| | - Thomas N Wight
- the Matrix Biology Program, Benaroya Research Institute, Seattle, Washington 98101
| | | | - Paul L Bollyky
- From the Department of Medicine, Division of Infectious Diseases
| | - Manish J Butte
- the Department of Pediatrics, Division of Immunology, Allergy, and Rheumatology, Stanford University, Stanford, California 94305 and
| |
Collapse
|
30
|
Liu R, Patel D, Screen HRC, Becer CR. A2B-Miktoarm Glycopolymer Fibers and Their Interactions with Tenocytes. Bioconjug Chem 2017. [DOI: 10.1021/acs.bioconjchem.7b00279] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Renjie Liu
- Polymer Chemistry Laboratory and ‡Institute of Bioengineering,
School of Engineering and Materials Science, Queen Mary, University of London, E1 4NS London, United Kingdom
| | - Dharmesh Patel
- Polymer Chemistry Laboratory and ‡Institute of Bioengineering,
School of Engineering and Materials Science, Queen Mary, University of London, E1 4NS London, United Kingdom
| | - Hazel R. C. Screen
- Polymer Chemistry Laboratory and ‡Institute of Bioengineering,
School of Engineering and Materials Science, Queen Mary, University of London, E1 4NS London, United Kingdom
| | - C. Remzi Becer
- Polymer Chemistry Laboratory and ‡Institute of Bioengineering,
School of Engineering and Materials Science, Queen Mary, University of London, E1 4NS London, United Kingdom
| |
Collapse
|
31
|
Exposure to buffer solution alters tendon hydration and mechanics. J Biomech 2017; 61:18-25. [PMID: 28720201 DOI: 10.1016/j.jbiomech.2017.06.045] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 06/20/2017] [Accepted: 06/29/2017] [Indexed: 11/22/2022]
Abstract
A buffer solution is often used to maintain tissue hydration during mechanical testing. The most commonly used buffer solution is a physiological concentration of phosphate buffered saline (PBS); however, PBS increases the tissue's water content and decreases its tensile stiffness. In addition, solutes from the buffer can diffuse into the tissue and interact with its structure and mechanics. These bathing solution effects can confound the outcome and interpretation of mechanical tests. Potential bathing solution artifacts, including solute diffusion, and their effect on mechanical properties, are not well understood. The objective of this study was to measure the effects of long-term exposure of rat tail tendon fascicles to several concentrations (0.9-25%) of NaCl, sucrose, polyethylene glycol (PEG), and SPEG (NaCl+PEG) solutions on water content, solute diffusion, and mechanical properties. We found that with an increase in solute concentration the apparent water content decreased for all solution types. Solutes diffused into the tissue for NaCl and sucrose, however, no solute diffusion was observed for PEG or SPEG. The mechanical properties changed for both NaCl solutions, in particular after long-term (8h) incubation the modulus and equilibrium stress decreased compared to short-term (15min) for 25% NaCl, and the cross sectional area increased for 0.9% NaCl. However, the mechanical properties were unchanged for both PEG and SPEG except for minor alterations in stress relaxation parameters. This study shows that NaCl and sucrose buffer solutions are not suitable for long-term mechanical tests. We therefore propose using PEG or SPEG as alternative buffer solutions that after long-term incubation can maintain tissue hydration without solute diffusion and produce a consistent mechanical response.
Collapse
|
32
|
Rossetti L, Kuntz LA, Kunold E, Schock J, Müller KW, Grabmayr H, Stolberg-Stolberg J, Pfeiffer F, Sieber SA, Burgkart R, Bausch AR. The microstructure and micromechanics of the tendon-bone insertion. NATURE MATERIALS 2017; 16:664-670. [PMID: 28250445 DOI: 10.1038/nmat4863] [Citation(s) in RCA: 172] [Impact Index Per Article: 24.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Accepted: 01/17/2017] [Indexed: 05/28/2023]
Abstract
The exceptional mechanical properties of the load-bearing connection of tendon to bone rely on an intricate interplay of its biomolecular composition, microstructure and micromechanics. Here we identify that the Achilles tendon-bone insertion is characterized by an interface region of ∼500 μm with a distinct fibre organization and biomolecular composition. Within this region, we identify a heterogeneous mechanical response by micromechanical testing coupled with multiscale confocal microscopy. This leads to localized strains that can be larger than the remotely applied strain. The subset of fibres that sustain the majority of loading in the interface area changes with the angle of force application. Proteomic analysis detects enrichment of 22 proteins in the interfacial region that are predominantly involved in cartilage and skeletal development as well as proteoglycan metabolism. The presented mechanisms mark a guideline for further biomimetic strategies to rationally design hard-soft interfaces.
Collapse
Affiliation(s)
- L Rossetti
- Lehrstuhl für Zellbiophysik, Technische Universität München, D-85748 Garching, Germany
| | - L A Kuntz
- Lehrstuhl für Zellbiophysik, Technische Universität München, D-85748 Garching, Germany
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, D-81675 München, Germany
| | - E Kunold
- Center for Integrated Protein Science (CIPSM), Department of Chemistry, Technische Universität München, D-85747 Garching, Germany
| | - J Schock
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, D-85748 Garching, Germany
| | - K W Müller
- Institute for Computational Mechanics, Technische Universität München, D-85748 Garching, Germany
- Structural and Applied Mechanics Group, Computational Engineering Division, Lawrence Livermore National Laboratory, 7000 East Ave, Livermore, California 94550, USA
| | - H Grabmayr
- Lehrstuhl für Zellbiophysik, Technische Universität München, D-85748 Garching, Germany
- Department of Physics and Center for Nanoscience, Ludwig Maximilian University, D-80539 Munich, Germany
| | - J Stolberg-Stolberg
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, D-81675 München, Germany
- University Hospital Münster, Department of Trauma-, Hand- and Reconstructive Surgery, Albert-Schweitzer-Campus 1, Building W1, D-48149 Münster, Germany
| | - F Pfeiffer
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, D-85748 Garching, Germany
- Institut für diagnostische und interventionelle Radiologie, Klinikum rechts der Isar, Technische Universität München, D-81675 München, Germany
| | - S A Sieber
- Center for Integrated Protein Science (CIPSM), Department of Chemistry, Technische Universität München, D-85747 Garching, Germany
| | - R Burgkart
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, D-81675 München, Germany
| | - A R Bausch
- Lehrstuhl für Zellbiophysik, Technische Universität München, D-85748 Garching, Germany
| |
Collapse
|
33
|
Haslerud S, Lopes-Martins RAB, Frigo L, Bjordal JM, Marcos RL, Naterstad IF, Magnussen LH, Joensen J. Low-Level Laser Therapy and Cryotherapy as Mono- and Adjunctive Therapies for Achilles Tendinopathy in Rats. Photomed Laser Surg 2017; 35:32-42. [DOI: 10.1089/pho.2016.4150] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Affiliation(s)
- Sturla Haslerud
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | | | - Lúcio Frigo
- Centro de Ciências da Saúde, Universidade Cruzeiro do Sul, São Paulo, Brazil
| | - Jan Magnus Bjordal
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Rodrigo Labat Marcos
- Programa de Pós-Graduação em Biofotônica Aplicada as Ciências da Saúde, Universidade Nove de Julho, São Paulo, Brazil
| | - Ingvill Fjell Naterstad
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Liv Heide Magnussen
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Department of Occupational Therapy, Physiotherapy and Radiography, Faculty of Health and Social Sciences, Bergen University College, Bergen, Norway
| | - Jon Joensen
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Department of Occupational Therapy, Physiotherapy and Radiography, Faculty of Health and Social Sciences, Bergen University College, Bergen, Norway
| |
Collapse
|
34
|
Fang F, Lake SP. Multiscale mechanical integrity of human supraspinatus tendon in shear after elastin depletion. J Mech Behav Biomed Mater 2016; 63:443-455. [PMID: 27472764 DOI: 10.1016/j.jmbbm.2016.06.032] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 06/27/2016] [Accepted: 06/30/2016] [Indexed: 01/28/2023]
Abstract
Human supraspinatus tendon (SST) exhibits region-specific nonlinear mechanical properties under tension, which have been attributed to its complex multiaxial physiological loading environment. However, the mechanical response and underlying multiscale mechanism regulating SST behavior under other loading scenarios are poorly understood. Furthermore, little is known about the contribution of elastin to tendon mechanics. We hypothesized that (1) SST exhibits region-specific shear mechanical properties, (2) fiber sliding is the predominant mode of local matrix deformation in SST in shear, and (3) elastin helps maintain SST mechanical integrity by facilitating force transfer among collagen fibers. Through the use of biomechanical testing and multiphoton microscopy, we measured the multiscale mechanical behavior of human SST in shear before and after elastase treatment. Three distinct SST regions showed similar stresses and microscale deformation. Collagen fiber reorganization and sliding were physical mechanisms observed as the SST response to shear loading. Measures of microscale deformation were highly variable, likely due to a high degree of extracellular matrix heterogeneity. After elastase treatment, tendon exhibited significantly decreased stresses under shear loading, particularly at low strains. These results show that elastin contributes to tendon mechanics in shear, further complementing our understanding of multiscale tendon structure-function relationships.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering & Materials Science, Washington University in St. Louis, United States
| | - Spencer P Lake
- Department of Mechanical Engineering & Materials Science, Washington University in St. Louis, United States; Department of Biomedical Engineering, Washington University in St. Louis, United States; Department of Orthopaedic Surgery, Washington University in St. Louis, United States.
| |
Collapse
|
35
|
Choi RK, Smith MM, Martin JH, Clarke JL, Dart AJ, Little CB, Clarke EC. Chondroitin sulphate glycosaminoglycans contribute to widespread inferior biomechanics in tendon after focal injury. J Biomech 2016; 49:2694-2701. [PMID: 27316761 DOI: 10.1016/j.jbiomech.2016.06.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Revised: 05/28/2016] [Accepted: 06/01/2016] [Indexed: 11/24/2022]
Abstract
Both mechanical and structural properties of tendon change after injury however the causal relationship between these properties is presently unclear. This study aimed to determine the extent of biomechanical change in post-injury tendon pathology and whether the sulphated glycosaminoglycans (glycosaminoglycans) present are a causal factor in these changes. Equine superficial digital flexor tendons (SDF tendons) were surgically-injured in vivo (n=6 injured, n=6 control). Six weeks later they were harvested and regionally dissected into twelve regions around the lesion (equal medial/lateral, proximal/distal). Glycosaminoglycans were removed by enzymatic (chondroitinase) treatment. Elastic modulus (modulus) and ultimate tensile strength (UTS) were measured under uniaxial tension to failure, and tendon glycosaminoglycan content was measured by spectrophotometry. Compared to healthy tendons, pathology induced by the injury decreased modulus (-38%; 95%CI -49% to -28%; P<0.001) and UTS (-38%; 95%CI -48% to -28%; P<0.001) and increased glycosaminoglycan content (+52%; 95%CI 39% - 64%; P<0.001) throughout the tendon. Chondroitinase-mediated glycosaminoglycan removal (50%; 95%CI 21-79%; P<0.001) in surgically-injured pathological tendons caused a significant increase in modulus (5.6MPa/µg removed; 95%CI 0.31-11; P=0.038) and UTS (1.0MPa per µg removed; 95%CI 0.043-2; P=0.041). These results demonstrate that the chondroitin/dermatan sulphate glycosaminoglycans that accumulate in pathological tendon post-injury are partly responsible for the altered biomechanical properties.
Collapse
Affiliation(s)
- Rachel K Choi
- Murray Maxwell Biomechanics Laboratory (Institute of Bone and Joint Research), Kolling Institute, Royal North Shore Hospital (Sydney Medical School, University of Sydney), St Leonards, New South Wales, Australia; Raymond Purves Bone and Joint Research Laboratories (Institute of Bone and Joint Research), Kolling Institute, Royal North Shore Hospital (Sydney Medical School, University of Sydney), St Leonards, New South Wales, Australia
| | - Margaret M Smith
- Raymond Purves Bone and Joint Research Laboratories (Institute of Bone and Joint Research), Kolling Institute, Royal North Shore Hospital (Sydney Medical School, University of Sydney), St Leonards, New South Wales, Australia
| | - Joshua H Martin
- Murray Maxwell Biomechanics Laboratory (Institute of Bone and Joint Research), Kolling Institute, Royal North Shore Hospital (Sydney Medical School, University of Sydney), St Leonards, New South Wales, Australia
| | - Jillian L Clarke
- Faculty of Health Sciences, University of Sydney, Lidcombe, New South Wales, Australia
| | - Andrew J Dart
- Research and Clinical Training Unit, University Veterinary Teaching Hospital, University of Sydney, Camden, New South Wales, Australia
| | - Christopher B Little
- Raymond Purves Bone and Joint Research Laboratories (Institute of Bone and Joint Research), Kolling Institute, Royal North Shore Hospital (Sydney Medical School, University of Sydney), St Leonards, New South Wales, Australia.
| | - Elizabeth C Clarke
- Murray Maxwell Biomechanics Laboratory (Institute of Bone and Joint Research), Kolling Institute, Royal North Shore Hospital (Sydney Medical School, University of Sydney), St Leonards, New South Wales, Australia
| |
Collapse
|
36
|
Tamori M, Ishida K, Matsuura E, Ogasawara K, Hanasaka T, Takehana Y, Motokawa T, Osawa T. Ultrastructural Changes Associated with Reversible Stiffening in Catch Connective Tissue of Sea Cucumbers. PLoS One 2016; 11:e0155673. [PMID: 27192546 PMCID: PMC4871580 DOI: 10.1371/journal.pone.0155673] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 05/02/2016] [Indexed: 11/18/2022] Open
Abstract
The dermis of sea cucumbers is a catch connective tissue or a mutable collagenous tissue that shows rapid, large and reversible stiffness changes in response to stimulation. The main component of the dermis is the extracellular material composed of collagen fibrils embedded in a hydrogel of proteoglycans. The stiffness of the extracellular material determines that of the dermis. The dermis has three mechanical states: soft (Sa), standard (Sb) and stiff (Sc). We studied the ultrastructural changes associated with the stiffness changes. Transverse sections of collagen fibrils in the dermis showed irregular perimeters with electron-dense protrusions or arms that cross-bridged between fibrils. The number of cross-bridges increased in stiffer dermis. The distance between the fibrils was shorter in Sc than that in other states, which was in accord with the previous report that water exuded from the tissue in the transition Sb→Sc. The ultrastructure of collagen fibrils that had been isolated from the dermis was also studied. Fibrils aggregated by tensilin, which causes the transition Sa→Sb possibly through an increase in cohesive forces between fibrils, had larger diameter than those dispersed by softenin, which antagonizes the effect of tensilin. No cross-bridges were found in isolated collagen fibrils. From the present ultrastructural study we propose that three different mechanisms work together to increase the dermal stiffness. 1.Tensilin makes collagen fibrils stronger and stiffer in Sa→Sb through an increase in cohesive forces between subfibrils that constituted fibrils; 2. Cross-bridging by arms caused the fibrils to be a continuous network of bundles both in Sa→Sb and in Sb→Sc; 3. The matrix embedding the fibril network became stiffer in Sb→Sc, which was produced by bonding associated with water exudation.
Collapse
Affiliation(s)
- Masaki Tamori
- Department of Biological Sciences, Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, Meguro-ku, Tokyo, Japan
- * E-mail:
| | - Kinji Ishida
- The Center for Electron Microscopy & Bio-imaging Research, Central Research Laboratories, Iwate Medical University, Morioka, Iwate, Japan
| | - Eri Matsuura
- The Center for Electron Microscopy & Bio-imaging Research, Central Research Laboratories, Iwate Medical University, Morioka, Iwate, Japan
| | - Katsutoshi Ogasawara
- The Center for Electron Microscopy & Bio-imaging Research, Central Research Laboratories, Iwate Medical University, Morioka, Iwate, Japan
| | - Tomohito Hanasaka
- The Center for Electron Microscopy & Bio-imaging Research, Central Research Laboratories, Iwate Medical University, Morioka, Iwate, Japan
| | - Yasuhiro Takehana
- Department of Biological Sciences, Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, Meguro-ku, Tokyo, Japan
- Laboratory of Microbiology, Institute of Microbial Chemistry (BIKAKEN), Shinagawa-ku, Tokyo, Japan
| | - Tatsuo Motokawa
- Department of Biological Sciences, Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, Meguro-ku, Tokyo, Japan
| | - Tokuji Osawa
- Kyushu Nutrition Welfare University, Kitakyushu, Fukuoka, Japan
| |
Collapse
|
37
|
Screen HRC, Berk DE, Kadler KE, Ramirez F, Young MF. Tendon functional extracellular matrix. J Orthop Res 2015; 33:793-9. [PMID: 25640030 PMCID: PMC4507431 DOI: 10.1002/jor.22818] [Citation(s) in RCA: 133] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 12/13/2014] [Indexed: 02/06/2023]
Abstract
This article is one of a series, summarizing views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the "Functional Extracellular Matrix" stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment, and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely varying extrinsic and intrinsic factors such as age, nutrition, exercise levels, and biomechanics. Consequently, tendon adapts dynamically during development, aging, and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair.
Collapse
Affiliation(s)
- Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London, E1 4NS, United Kingdom
| | | | | | | | | |
Collapse
|
38
|
The Mechanical, Structural, and Compositional Changes of Tendon Exposed to Elastase. Ann Biomed Eng 2015; 43:2477-86. [PMID: 25808209 DOI: 10.1007/s10439-015-1308-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Accepted: 03/20/2015] [Indexed: 01/24/2023]
Abstract
The mechanical response of tendon is dependent on the interaction of structural molecules that constitute the extracellular matrix. However, little is known about the role of elastic fibers that are present in this structure. Elastase treatments have been used to elucidate the mechanical role of elastic fibers in numerous tissues. Here, we show that a standard elastase treatment affects the mechanical properties of tendon, including the ultimate tensile strength and failure strain. Moreover, elastase-treated specimens exhibit significant structural and compositional changes including crimp undulation and release of glycosaminoglycans. These data demonstrate that a common elastase treatment has a complex digestion profile that influences the structure-function relationship of tendon. Thus, defining the mechanical role of elastic fibers in tendon using this technique is challenging. This introduces new and exciting questions regarding the function of elastic fibers in tendon, which may not be as well understood as previously thought.
Collapse
|
39
|
Hatami-Marbini H, Rahimi A. The relation between hydration and mechanical behavior of bovine cornea in tension. J Mech Behav Biomed Mater 2014; 36:90-7. [DOI: 10.1016/j.jmbbm.2014.03.011] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Revised: 03/15/2014] [Accepted: 03/18/2014] [Indexed: 11/30/2022]
|
40
|
Gonzalez AD, Gallant MA, Burr DB, Wallace JM. Multiscale analysis of morphology and mechanics in tail tendon from the ZDSD rat model of type 2 diabetes. J Biomech 2013; 47:681-6. [PMID: 24360194 DOI: 10.1016/j.jbiomech.2013.11.045] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 11/19/2013] [Accepted: 11/24/2013] [Indexed: 01/20/2023]
Abstract
Type 2 diabetes (T2D) impacts multiple organ systems including the circulatory, renal, nervous and musculoskeletal systems. In collagen-based tissues, one mechanism that may be responsible for detrimental mechanical impacts of T2D is the formation of advanced glycation end products (AGEs) leading to increased collagen stiffness and decreased toughness, resulting in brittle tissue behavior. The purpose of this study was to investigate tendon mechanical properties from normal and diabetic rats at two distinct length scales, testing the hypothesis that increased stiffness and strength and decreased toughness at the fiber level would be associated with alterations in nanoscale morphology and mechanics. Individual fascicles from female Zucker diabetic Sprague-Dawley (ZDSD) rats had no differences in fascicle-level mechanical properties but had increased material-level strength and stiffness versus control rats (CD). At the nanoscale, collagen fibril D-spacing was shifted towards higher spacing values in diabetic ZDSD fibrils. The distribution of nanoscale modulus values was also shifted to higher values. Material-level strength and stiffness from whole fiber tests were increased in ZDSD tails. Correlations between nanoscale and microscale properties indicate a direct positive relationship between the two length scales, most notably in the relationship between nanoscale and microscale modulus. These findings indicate that diabetes-induced changes in material strength and modulus were driven by alterations at the nanoscale.
Collapse
Affiliation(s)
- Armando Diaz Gonzalez
- Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis, 723 W Michigan Street SL220D, Indianapolis, IN 46202, USA
| | - Maxime A Gallant
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - David B Burr
- Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis, 723 W Michigan Street SL220D, Indianapolis, IN 46202, USA; Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Joseph M Wallace
- Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis, 723 W Michigan Street SL220D, Indianapolis, IN 46202, USA; Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN, USA.
| |
Collapse
|
41
|
Marcos RL, Arnold G, Magnenet V, Rahouadj R, Magdalou J, Lopes-Martins RÁB. Biomechanical and biochemical protective effect of low-level laser therapy for Achilles tendinitis. J Mech Behav Biomed Mater 2013; 29:272-85. [PMID: 24126100 DOI: 10.1016/j.jmbbm.2013.08.028] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2013] [Revised: 08/23/2013] [Accepted: 08/27/2013] [Indexed: 11/25/2022]
Abstract
For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofenac, have been compared in the case of collagenase-induced Achilles tendinitis. Wistar rats were treated with diclofenac or laser therapy. The tensile behavior of tendons was characterized through successive loading-unloading sequences. The method considered 11 characteristic parameters to describe the mechanical behavior. It was shown that during the acute inflammatory process of the tendon, the mechanical properties were significantly correlated to the high levels of MMP-3, MMP-9 and MMP-13 expression presented in a previous paper (Marcos, R.L., et al., 2012). The treatment by non-steroidal anti-inflammatory drugs such as diclofenac sodium produces a low protective effect and can affect the short-term biochemical and biomechanical properties. On the contrary, it is shown that LLLT exhibits the best results in terms of MMPs reduction and mechanical properties recovery. Thus, LLLT looks to be a promising and consistent treatment for tendinopathies.
Collapse
Affiliation(s)
- Rodrigo Labat Marcos
- University of Nove de Julho, Biophotonics Applied to Health Sciences, São Paulo 01504-001, Brazil; University of São Paulo (USP), Laboratory of Pharmacology and Experimental Therapeutics, Institute of Biomedical Sciences (ICB), São Paulo 05508-900, Brazil; Université de Lorraine (UL), Ingénierie Moléculaire, Physiopathologie Articulaire (IMoPA), UMR 7365 CNRS, Biopôle, F-54505 Vandœuvre-lès-Nancy, France
| | | | | | | | | | | |
Collapse
|
42
|
Dourte LM, Pathmanathan L, Mienaltowski MJ, Jawad AF, Birk DE, Soslowsky LJ. Mechanical, compositional, and structural properties of the mouse patellar tendon with changes in biglycan gene expression. J Orthop Res 2013; 31:1430-7. [PMID: 23592048 PMCID: PMC3801205 DOI: 10.1002/jor.22372] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Accepted: 03/18/2013] [Indexed: 02/04/2023]
Abstract
Tendons have complex mechanical properties that depend on their structure and composition. Some studies have assessed the role of small leucine-rich proteoglycans (SLRPs) in the mechanical response of tendon, but the relationships between sophisticated mechanics, assembly of collagen and SLRPs have not been well characterized. In this study, biglycan gene expression was varied in a dose dependent manner using biglycan null, biglycan heterozygote and wild type mice. Measures of mechanical (tension and compression), compositional and structural changes of the mouse patellar tendon were evaluated. Viscoelastic, tensile dynamic modulus was found to be increased in the biglycan heterozygous and biglycan null tendons compared to wild type. Gene expression analyses revealed biglycan gene expression was closely associated in a dose-dependent allelic manner. No differences were seen between genotypes in elastic or compressive properties or quantitative measures of collagen structure. These results suggest that biglycan, a member of the SLRP family, plays a role in tendon viscoelasticity that cannot be completely explained by its role in collagen fibrillogenesis.
Collapse
Affiliation(s)
- LeAnn M. Dourte
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, Pennsylvania, 19104-6081
| | - Lydia Pathmanathan
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, Pennsylvania, 19104-6081
| | - Michael J. Mienaltowski
- Department of Molecular Pharmacology and Physiology, University of South Florida Morsani College of Medicine, Tampa, Florida
| | - Abbas F. Jawad
- Department of Pediatrics – Biostatistics and Epidemiology, University of Pennsylvania Perelman School of Medicine/Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - David E. Birk
- Department of Molecular Pharmacology and Physiology, University of South Florida Morsani College of Medicine, Tampa, Florida
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, Pennsylvania, 19104-6081
| |
Collapse
|
43
|
Legerlotz K, Riley GP, Screen HR. GAG depletion increases the stress-relaxation response of tendon fascicles, but does not influence recovery. Acta Biomater 2013; 9:6860-6. [PMID: 23462553 PMCID: PMC3666056 DOI: 10.1016/j.actbio.2013.02.028] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Revised: 02/06/2013] [Accepted: 02/08/2013] [Indexed: 11/28/2022]
Abstract
Cyclic and static loading regimes are commonly used to study tenocyte metabolism in vitro and to improve our understanding of exercise-associated tendon pathologies. The aims of our study were to investigate if cyclic and static stress relaxation affected the mechanical properties of tendon fascicles differently, if this effect was reversible after a recovery period, and if the removal of glycosaminoglycans (GAGs) affected sample recovery. Tendon fascicles were dissected frombovine-foot extensors and subjected to 14% cyclic (1Hz) or static tensile strain for 30min. Additional fascicles were incubated overnight in buffer with 0.5U chondroitinase ABC or in buffer alone prior to the static stress-relaxation regime. To assess the effect of different stress-relaxation regimes, a quasi-static test to failure was carried out, either directly post loading or after a 2h recovery period, and compared with unloaded control fascicles. Both stress-relaxation regimes led to a significant reduction in fascicle failure stress and strain, but this was more pronounced in the cyclically loaded specimens. Removal of GAGs led to more stress relaxation and greater reductions in failure stress after static loading compared to controls. The reduction in mechanical properties was partially reversible in all samples, given a recovery period of 2h. This has implications for mechanical testing protocols, as a time delay between fatiguing specimens and characterization of mechanical properties will affect the results. GAGs appear to protect tendon fascicles from fatigue effects, possibly by enabling sample hydration.
Collapse
Affiliation(s)
- Kirsten Legerlotz
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich, UK
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
- Corresponding author. Address: School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich NR4 7TJ, UK. Tel.: +44 1603 591785; fax: +44 1603 592250. k.s.l.@gmx.de
| | - Graham P. Riley
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich, UK
| | - Hazel R.C. Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
| |
Collapse
|
44
|
Thompson MS. Tendon mechanobiology: experimental models require mathematical underpinning. Bull Math Biol 2013; 75:1238-54. [PMID: 23681792 DOI: 10.1007/s11538-013-9850-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2012] [Accepted: 04/25/2013] [Indexed: 10/26/2022]
Abstract
Mathematical and computational modeling is in demand to help address current challenges in mechanobiology of musculoskeletal tissues. In particular for tendon, the high clinical importance of the tissue, the huge mechanical demands placed on it and its ability to adapt to these demands, require coupled, multiscale models incorporating complex geometrical and microstructural information as well as time-based descriptions of cellular activity and response.This review introduces the information sources required to develop such multiscale models. It covers tissue structure and biomechanics, cell biomechanics, the current understanding of tendon's ability in health and disease to update its properties and structure and the few already existing multiscale mechanobiological models of the tissue. Finally, a sketch is provided of what such models could achieve ideally, pointing out where experimental data and knowledge are still missing.
Collapse
Affiliation(s)
- Mark S Thompson
- Institute of Biomedical Engineering, Botnar Research Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD, UK.
| |
Collapse
|
45
|
Buckley MR, Huffman GR, Iozzo RV, Birk DE, Soslowsky LJ. The location-specific role of proteoglycans in the flexor carpi ulnaris tendon. Connect Tissue Res 2013; 54:367-73. [PMID: 23941206 PMCID: PMC4406324 DOI: 10.3109/03008207.2013.832232] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Tendons like the flexor carpi ulnaris (FCU) that contain region-specific distributions of proteoglycans (PGs) as a result of the heterogeneous, multi-axial loads they are subjected to in vivo provide valuable models for understanding structure-function relationships in connective tissues. However, the contributions of specific PGs to FCU tendon mechanical properties are unknown. Therefore, the objective of this study was to determine how the location-dependent, viscoelastic mechanical properties of the FCU tendon are impacted individually by PG-associated glycosaminoglycans (GAGs) and by two small leucine-rich proteoglycans (SLRPs), biglycan and decorin. Full length FCU tendons from biglycan- and decorin-null mice were compared to wild-type (WT) mice to evaluate the effects of specific SLRPs, while chondroitinase ABC digestion of isolated specimens removed from the tendon midsubstance was used to determine how chondroitin/dermatan sulfate (CS/DS) GAGs impact mechanics in mature FCU tendons. A novel combined genetic knockout/digestion technique also was employed to compare SLRP-null and WT tendons in the absence of CS/DS GAGs that may impact properties in the mature state. In all genotypes, mechanical properties in the FCU tendon midsubstance were not affected by GAG digestion. Full-length tendons exhibited complex, multi-axial deformation under tension that may be associated with their in vivo loading environment. Mechanical properties were adversely affected by the absence of biglycan, and a decreased modulus localized in the center of the tendon was measured. These results help elucidate the role that local alterations in PG levels may play in processes that adversely impact tendon functionality including injury and pathology.
Collapse
Affiliation(s)
- Mark R. Buckley
- Department of Orthopaedic Research, University of Pennsylvania, Philadelphia, PA
| | - George R. Huffman
- Department of Orthopaedic Research, University of Pennsylvania, Philadelphia, PA
| | - Renato V. Iozzo
- Department of Pathology and Cell Biology, Thomas Jefferson University, Philadelphia, PA
| | - David E. Birk
- Department of Molecular Pharmacology and Physiology, University of South Florida, Tampa, FL
| | - Louis J. Soslowsky
- Department of Orthopaedic Research, University of Pennsylvania, Philadelphia, PA,Corresponding author: Louis J Soslowsky, PhD, McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, 424 Stemmler Hall, 36th Street and Hamilton Walk, Philadelphia, PA 19104-6081, Phone: 215-898-8653; Fax: 2 215-573-2133;
| |
Collapse
|
46
|
Duncan NA, Bruehlmann SB, Hunter CJ, Shao X, Kelly EJ. In situ cell-matrix mechanics in tendon fascicles and seeded collagen gels: implications for the multiscale design of biomaterials. Comput Methods Biomech Biomed Engin 2012; 17:39-47. [PMID: 23237459 DOI: 10.1080/10255842.2012.742075] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Designing biomaterials to mimic and function within the complex mechanobiological conditions of connective tissues requires a detailed understanding of the micromechanical environment of the cell. The objective of our study was to measure the in situ cell-matrix strains from applied tension in both tendon fascicles and cell-seeded type I collagen scaffolds using laser scanning confocal microscopy techniques. Tendon fascicles and collagen gels were fluorescently labelled to simultaneously visualise the extracellular matrix and cell nuclei under applied tensile strains of 5%. There were significant differences observed in the micromechanics at the cell-matrix scale suggesting that the type I collagen scaffold did not replicate the pattern of native tendon strains. In particular, although the overall in situ tensile strains in the matrix were quite similar (∼2.5%) between the tendon fascicles and the collagen scaffolds, there were significant differences at the cell-matrix boundary with visible shear across cell nuclei of >1 μm measured in native tendon which was not observed at all in the collagen scaffolds. Similarly, there was significant non-uniformity of intercellular strains with relative sliding observed between cell rows in tendon which again was not observed in the collagen scaffolds where the strain environment was much more uniform. If the native micromechanical environment is not replicated in biomaterial scaffolds, then the cells may receive incorrect or mixed mechanical signals which could affect their biosynthetic response to mechanical load in tissue engineering applications. This study highlights the importance of considering the microscale mechanics in the design of biomaterial scaffolds and the need to incorporate such features in computational models of connective tissues.
Collapse
Affiliation(s)
- Neil A Duncan
- a McCaig Institute for Bone and Joint Health, University of Calgary , 2500 University Drive, NW, Calgary AB Canada T2N 1N4
| | | | | | | | | |
Collapse
|
47
|
Han WM, Nerurkar NL, Smith LJ, Jacobs NT, Mauck RL, Elliott DM. Multi-scale structural and tensile mechanical response of annulus fibrosus to osmotic loading. Ann Biomed Eng 2012; 40:1610-21. [PMID: 22314837 DOI: 10.1007/s10439-012-0525-4] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2011] [Accepted: 01/27/2012] [Indexed: 01/04/2023]
Abstract
This study investigates differential multi-scale structure and function relationships of the outer and inner annulus fibrosus (AF) to osmotic swelling in different buffer solutions by quantifying tensile mechanics, glycoasamino-glycan(GAG) content, water content and tissue swelling, and collagen fibril ultrastructure. In the outer AF, the tensile modulus decreased by over 70% with 0.15 M PBS treatment but was unchanged with 2 M PBS treatment. Moreover, the modulus loss following 0.15 M PBS treatment was reversed when followed by 2 M PBS treatment, potentially from increased interfibrillar and interlamellar shearing associated with fibril swelling. In contrast, the inner AF tensile modulus was unchanged by 0.15 M PBS treatment and increased following 2 M treatment. Transmission electron microscopy revealed that the mean collagen fibril diameters of the untreated outer and inner AF were 87.8 ± 27.9 and 71.0 ± 26.9 nm, respectively. In the outer AF, collagen fibril swelling was observed with both 0.15 M and 2 M PBS treatments, but inherently low GAG content remained unchanged. In the inner AF, 2 M PBS treatment caused fibril swelling and GAG loss, suggesting that GAG plays a role in maintaining the structure of collagen fibrils leading to modulation of the native tissue mechanical properties. These results demonstrate important regional variations in structure and composition, and their influence on the heterogeneous mechanics of the AF. Moreover, because the composition and structure is altered as a consequence of progressive disk degeneration, quantification of these interactions is critical for study of the AF pathogenesis of degeneration and tissue engineering
Collapse
Affiliation(s)
- Woojin M Han
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA 19104, USA
| | | | | | | | | | | |
Collapse
|
48
|
Screen HRC, Toorani S, Shelton JC. Microstructural stress relaxation mechanics in functionally different tendons. Med Eng Phys 2012; 35:96-102. [PMID: 22652381 DOI: 10.1016/j.medengphy.2012.04.004] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 04/01/2012] [Accepted: 04/15/2012] [Indexed: 11/19/2022]
Abstract
Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs.
Collapse
Affiliation(s)
- H R C Screen
- School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, London E1 4NS, UK.
| | | | | |
Collapse
|
49
|
Svensson RB, Hansen P, Hassenkam T, Haraldsson BT, Aagaard P, Kovanen V, Krogsgaard M, Kjaer M, Magnusson SP. Mechanical properties of human patellar tendon at the hierarchical levels of tendon and fibril. J Appl Physiol (1985) 2012; 112:419-26. [DOI: 10.1152/japplphysiol.01172.2011] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its distinct collagen fibrils would display similar mechanical properties. Human patellar tendons ( n = 5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon, and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young's modulus was 2.0 ± 0.5 GPa, and the toe region reached 3.3 ± 1.9% strain in whole patellar tendons. Based on dry cross-sectional area, the Young's modulus of isolated collagen fibrils was 2.8 ± 0.3 GPa, and the toe region reached 0.86 ± 0.08% strain. The measured fibril modulus was insufficient to account for the modulus of the tendon in vivo when fibril content in the tendon was accounted for. Thus, our original hypothesis was not supported, although the in vitro fibril modulus corresponded well with reported in vitro tendon values. This correspondence together with the fibril modulus not being greater than that of tendon supports that fibrillar rather than interfibrillar properties govern the subfailure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition to the primary work comparing the two hierarchical levels, we also verified the existence of viscoelastic behavior in isolated human collagen fibrils.
Collapse
Affiliation(s)
- René B. Svensson
- Faculty of Health Sciences, Institute of Sports Medicine Copenhagen, Bispebjerg Hospital & Center for Healthy Aging, University of Copenhagen, Copenhagen
- Nano-Science Center, University of Copenhagen, Copenhagen
| | - Philip Hansen
- Faculty of Health Sciences, Institute of Sports Medicine Copenhagen, Bispebjerg Hospital & Center for Healthy Aging, University of Copenhagen, Copenhagen
| | - Tue Hassenkam
- Nano-Science Center, University of Copenhagen, Copenhagen
| | - Bjarki T. Haraldsson
- Faculty of Health Sciences, Institute of Sports Medicine Copenhagen, Bispebjerg Hospital & Center for Healthy Aging, University of Copenhagen, Copenhagen
| | - Per Aagaard
- Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense
| | - Vuokko Kovanen
- Biochemistry Laboratory, Department of Health Sciences, University of Jyväskylä, Jyväskylä, Finland
| | - Michael Krogsgaard
- Department of Orthopedic Surgery, Bispebjerg Hospital, Copenhagen, Denmark; and
| | - Michael Kjaer
- Faculty of Health Sciences, Institute of Sports Medicine Copenhagen, Bispebjerg Hospital & Center for Healthy Aging, University of Copenhagen, Copenhagen
| | - S. Peter Magnusson
- Faculty of Health Sciences, Institute of Sports Medicine Copenhagen, Bispebjerg Hospital & Center for Healthy Aging, University of Copenhagen, Copenhagen
| |
Collapse
|
50
|
Sen S, Jacobs NT, Boxberger JI, Elliott DM. Human Annulus Fibrosus Dynamic Tensile Modulus Increases with Degeneration. MECHANICS OF MATERIALS : AN INTERNATIONAL JOURNAL 2012; 44:93-98. [PMID: 22247579 PMCID: PMC3254102 DOI: 10.1016/j.mechmat.2011.07.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The annulus fibrosus (AF) of the intervertebral disc experiences cyclic tensile loading in vivo at various states of mechanical equilibrium. Disc degeneration is associated with alterations in the biochemical composition of the AF including decreased water content, decreased proteoglycan concentration, and increased collagen deposition that affect mechanical function of the AF in compression and shear. Such changes may also affect the dynamic viscoelastic properties of the AF and thus alter the disc's ability to dissipate energy under physiologic loading. The objectives of this study were to quantify the dynamic viscoelastic properties of human AF in circumferential tension and to determine the effect of degeneration on these properties. Nondegenerated and degenerated human AF tensile samples were tested in uniaxial tension over a spectrum of loading frequencies spanning 0.01Hz to 2Hz at several states of equilibrium strain to determine the dynamic viscoelastic properties (dynamic modulus, phase angle) using a linear viscoelastic model. The AF dynamic modulus increased at higher equilibrium strain levels. The AF behaved more elastically at higher frequencies with a decreased phase angle. Degeneration resulted in a higher dynamic modulus at all strain levels but had no effect on phase angle. The findings from this study elucidate the effect of degeneration on the dynamic viscoelastic properties of human AF and lend insight into the mechanical role of the AF in cyclic loading conditions.
Collapse
Affiliation(s)
- Sounok Sen
- Department of Orthopaedic Surgery University of Pennsylvania Philadelphia, PA 19104
| | | | | | | |
Collapse
|