1
|
Ortiz-Santos E, Valdés-Ramírez G, Millán-Pacheco C, Serratos IN, Lozano-Camargo ML, Dalmasso P, Rivas GA, Galicia L. Experimental and In Silico Studies on the Development of an Electrochemical Biosensor for the Quantification of H 2O 2 Based on the ChOx Enzyme. BIOSENSORS 2025; 15:279. [PMID: 40422018 DOI: 10.3390/bios15050279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2025] [Revised: 04/01/2025] [Accepted: 04/08/2025] [Indexed: 05/28/2025]
Abstract
This work presents the development of a biosensing platform for hydrogen peroxide (H2O2) electrochemical reduction. The developed platform uses a multi-walled carbon nanotube paste (PMWCNT) and the enzyme cholesterol oxidase (ChOx). The supramolecular architecture of the PMWCNT/ChOx platform was characterized using cyclic voltammetry, electrochemical impedance spectroscopy, and amperometry. The results indicated that the presence of ChOx enhances the sensitivity of electrochemical detection for H2O2 by 21 times compared to that without ChOx. The designed electrochemical sensing bio-platform for H2O2 shows a sensitivity of 26.15 µA/mM in the linear range from 0.4 to 4.0 mM, an LOD of 0.43 µM, and an LOQ of 1.31 µM. Furthermore, in silico studies (molecular dynamics simulations, molecular docking assays, and binding free energy calculations (ΔGb)) were carried out to characterize and validate the molecular interaction between ChOx and H2O2. The computed data confirmed that the binding is spontaneous, and the type of labile interaction promotes a rapid electrochemical reduction of H2O2.
Collapse
Affiliation(s)
- Elvis Ortiz-Santos
- Departamento de Química, Universidad Autónoma Metropolitana Unidad Iztapalapa (UAM-I), Av. San Rafael Atlixco 186, Leyes de Reforma 1ra Secc., Mexico City 09340, Mexico
| | - Gabriela Valdés-Ramírez
- Departamento de Química, Universidad Autónoma Metropolitana Unidad Iztapalapa (UAM-I), Av. San Rafael Atlixco 186, Leyes de Reforma 1ra Secc., Mexico City 09340, Mexico
| | - Cesar Millán-Pacheco
- Facultad de Farmacia, Universidad Autónoma del Estado de Morelos (UAEM), Cuernavaca 62209, Mexico
| | - Iris N Serratos
- Departamento de Química, Universidad Autónoma Metropolitana Unidad Iztapalapa (UAM-I), Av. San Rafael Atlixco 186, Leyes de Reforma 1ra Secc., Mexico City 09340, Mexico
| | - Maria Luisa Lozano-Camargo
- Departamento de Ingeniería, Tecnológico de Estudios Superiores del Estado de México (TESOEM), La Paz 56400, Mexico
| | - Pablo Dalmasso
- Centro de Investigación en Química Aplicada (CIQA), CONICET, Departamento de Ingeniería Química, Facultad Regional de Córdoba, Universidad Nacional Tecnológica (UTN), Maestro López esq. Cruz Roja, Córdoba 5016, Argentina
| | - Gustavo A Rivas
- Instituto de Investigaciones en Físico-Química de Córdoba (INFIQC), Universidad Nacional de Córdoba (UNC), Av. Haya de la Torre, Córdoba 5000, Argentina
| | - Laura Galicia
- Departamento de Química, Universidad Autónoma Metropolitana Unidad Iztapalapa (UAM-I), Av. San Rafael Atlixco 186, Leyes de Reforma 1ra Secc., Mexico City 09340, Mexico
| |
Collapse
|
2
|
Singh K, Maurya KK, Malviya M. Recent progress on nanomaterial-based electrochemical sensors for glucose detection in human body fluids. Mikrochim Acta 2025; 192:110. [PMID: 39878884 DOI: 10.1007/s00604-025-06972-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2024] [Accepted: 01/10/2025] [Indexed: 01/31/2025]
Abstract
In the modern age, half of the population is facing various chronic illnesses due to glucose maintenance in the body, major causes of fatality and inefficiency. The early identification of glucose plays a crucial role in medical treatment and the food industry, particularly in diabetes diagnosis. In the past few years, non-enzymatic electrochemical glucose sensors have received a lot of interest for their ability to identify glucose levels accurately. Electrochemical biosensors are developing as a propitious solution for personalized health monitoring due to their accuracy, specificity, and affordability. This review article provides an observation of a variety of non-enzymatic glucose sensor resources, such as carbon nanomaterials, noble metals gold and silver, transition metal and their oxides, and porous material composites. Moreover, basic knowledge of the reaction mechanism of enzymatic and nonenzymatic glucose sensors are outlined and recent advancements in glucose sensors applications to various human body biofluids such as sweat, tears, urine, saliva, and blood are presented. Finally, this review summarizes electrochemical sensors for glucose detection in human body fluids, the challenges they faced, and their solutions.
Collapse
Affiliation(s)
- Kulveer Singh
- Indian Institute of Technology (BHU), Varanasi, 221005, India
| | | | - Manisha Malviya
- Indian Institute of Technology (BHU), Varanasi, 221005, India.
| |
Collapse
|
3
|
Amjad A, Xian X. Optical sensors for transdermal biomarker detection: A review. Biosens Bioelectron 2025; 267:116844. [PMID: 39406072 DOI: 10.1016/j.bios.2024.116844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 09/20/2024] [Accepted: 10/07/2024] [Indexed: 11/08/2024]
Abstract
This review has explored optical sensors and their important role in non-invasive transdermal biomarker detection. While electrochemical sensors have been thoroughly studied for biomarker tracking, optical sensors present a compelling alternative due to their high sensitivity and selectivity, multiplex capabilities, cost-efficiency, and small form factor. This review examines the latest advancements in optical sensing technologies for transdermal biomarker detection, such as colorimetry, fluorescence, surface plasmon resonance (SPR), fiber optics, photonic crystals, and Raman spectroscopy. These technologies have been applied in the analysis of biomarkers present in sweat and skin gases, which are essential for non-invasive health monitoring. Furthermore, the review has discussed the challenges and future perspectives of optical sensors in in transdermal biomarker detection. The analysis of various sensor types and their applications highlights the transformative potential of optical sensors in enhancing disease diagnostics and promoting proactive health management.
Collapse
Affiliation(s)
- Amirhossein Amjad
- McComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD, 57007, USA
| | - Xiaojun Xian
- McComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD, 57007, USA.
| |
Collapse
|
4
|
Shahzad S, Iftikhar FJ, Shah A, Rehman HA, Iwuoha E. Novel interfaces for internet of wearable electrochemical sensors. RSC Adv 2024; 14:36713-36732. [PMID: 39559568 PMCID: PMC11570917 DOI: 10.1039/d4ra07165d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2024] [Accepted: 10/21/2024] [Indexed: 11/20/2024] Open
Abstract
The integration of wearable devices, the Internet of Things (IoT), and advanced sensing platforms implies a significant paradigm shift in technological innovations and human interactions. The IoT technology allows continuous monitoring in real time. Thus, Internet of Wearables has made remarkable strides, especially in the field of medical monitoring. IoT-enabled wearable systems assist in early disease detection that facilitates personalized interventions and proactive healthcare management, thereby empowering individuals to take charge of their wellbeing. Until now, physical sensors have been successfully integrated into wearable devices for physical activity monitoring. However, obtaining biochemical information poses challenges in the contexts of fabrication compatibility and shorter operation lifetimes. IoT-based electrochemical wearable sensors allow real-time acquisition of data and interpretation of biomolecular information corresponding to biomarkers, viruses, bacteria and metabolites, extending the diagnostic capabilities beyond physical activity tracking. Thus, critical heath parameters such as glucose levels, blood pressure and cardiac rhythm may be monitored by these devices regardless of location and time. This work presents versatile electrochemical sensing devices across different disciplines, including but not limited to sports, safety and wellbeing by using IoT. It also discusses the detection principles for biomarkers and biofluid monitoring, and their integration into devices and advancements in sensing interfaces.
Collapse
Affiliation(s)
- Suniya Shahzad
- National University of Technology (NUTECH) Islamabad 44000 Pakistan
- Department of Chemistry, Quaid-i-Azam University Islamabad 45320 Pakistan
| | | | - Afzal Shah
- Department of Chemistry, Quaid-i-Azam University Islamabad 45320 Pakistan
| | | | - Emmanuel Iwuoha
- Sensorlab, Department of Chemistry, University of the Western Cape Private Bag X17 Bellville 7535 South Africa
| |
Collapse
|
5
|
Balconi M, Angioletti L, Crivelli D. Integrating EEG biomarkers in the neurocognitive screening of executive functions in substance and behavioral addiction. Front Psychiatry 2024; 15:1472565. [PMID: 39364385 PMCID: PMC11446767 DOI: 10.3389/fpsyt.2024.1472565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Accepted: 09/05/2024] [Indexed: 10/05/2024] Open
Affiliation(s)
- Michela Balconi
- International research center for Cognitive Applied Neuroscience (IrcCAN), Università Cattolica del Sacro Cuore, Milan, Italy
- Research Unit in Affective and Social Neuroscience, Department of Psychology, Università Cattolica del Sacro Cuore, Milan, Italy
| | - Laura Angioletti
- International research center for Cognitive Applied Neuroscience (IrcCAN), Università Cattolica del Sacro Cuore, Milan, Italy
- Research Unit in Affective and Social Neuroscience, Department of Psychology, Università Cattolica del Sacro Cuore, Milan, Italy
| | - Davide Crivelli
- International research center for Cognitive Applied Neuroscience (IrcCAN), Università Cattolica del Sacro Cuore, Milan, Italy
- Research Unit in Affective and Social Neuroscience, Department of Psychology, Università Cattolica del Sacro Cuore, Milan, Italy
| |
Collapse
|
6
|
Ji D, Zhu Y, Li M, Fan X, Zhang T, Li Y. Skin Comfort Sensation with Mechanical Stimulus from Electronic Skin. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2920. [PMID: 38930289 PMCID: PMC11204911 DOI: 10.3390/ma17122920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 04/30/2024] [Accepted: 05/20/2024] [Indexed: 06/28/2024]
Abstract
The field of electronic skin has received considerable attention due to its extensive potential applications in areas including tactile sensing and health monitoring. With the development of electronic skin devices, electronic skin can be attached to the surface of human skin for long-term health monitoring, which makes comfort an essential factor that cannot be ignored in the design of electronic skin. Therefore, this paper proposes an assessment method for evaluating the comfort of electronic skin based on neurodynamic analysis. The holistic analysis framework encompasses the mechanical model of the skin, the modified Hodgkin-Huxley model for the transduction of stimuli, and the gate control theory for the modulation and perception of pain sensation. The complete process, from mechanical stimulus to the generation of pain perception, is demonstrated. Furthermore, the influence of different factors on pain perception is investigated. Sensation and comfort diagrams are provided to assess the mechanical comfort of electronic skin. The comfort assessment method proposed in this paper provides a theoretical basis when assessing the comfort of electronic skin.
Collapse
Affiliation(s)
- Dongcan Ji
- Institute of Solid Mechanics, Beihang University (BUAA), Beijing 100191, China
| | - Yunfan Zhu
- Institute of Solid Mechanics, Beihang University (BUAA), Beijing 100191, China
| | - Min Li
- Institute of Solid Mechanics, Beihang University (BUAA), Beijing 100191, China
- International Innovation Institute, Beihang University (BUAA), Yuhang District, Hangzhou 311115, China
| | - Xuanqing Fan
- Institute of Solid Mechanics, Beihang University (BUAA), Beijing 100191, China
- International Innovation Institute, Beihang University (BUAA), Yuhang District, Hangzhou 311115, China
| | - Taihua Zhang
- Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
| | - Yuhang Li
- Institute of Solid Mechanics, Beihang University (BUAA), Beijing 100191, China
- Aircraft and Propulsion Laboratory, Ningbo Institute of Technology, Beihang University (BUAA), Ningbo 315100, China
| |
Collapse
|
7
|
Bayat M, Mardani H, Roghani-Mamaqani H, Hoogenboom R. Self-indicating polymers: a pathway to intelligent materials. Chem Soc Rev 2024; 53:4045-4085. [PMID: 38449438 DOI: 10.1039/d3cs00431g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
Self-indicating polymers have emerged as a promising class of smart materials that possess the unique ability to undergo detectable variations in their physical or chemical properties in response to various stimuli. This article presents an overview of the most important mechanisms through which these materials exhibit self-indication, including aggregation, phase transition, covalent and non-covalent bond cleavage, isomerization, charge transfer, and energy transfer. Aggregation is a prevalent mechanism observed in self-indicating polymers, where changes in the degree of molecular organization result in variations in optical or electrical properties. Phase transition-induced self-indication relies on the transformation between different phases, such as liquid-to-solid or crystalline-to-amorphous transitions, leading to observable changes in color or conductivity. Covalent bond cleavage-based self-indicating polymers undergo controlled degradation or fragmentation upon exposure to specific triggers, resulting in noticeable variations in their structural or mechanical properties. Isomerization is another crucial mechanism exploited in self-indicating polymers, where the reversible transformation between the different isomeric forms induces detectable changes in fluorescence or absorption spectra. Charge transfer-based self-indicating polymers rely on the modulation of electron or hole transfer within the polymer backbone, manifesting as changes in electrical conductivity or redox properties. Energy transfer is an essential mechanism utilized by certain self-indicating polymers, where energy transfer between chromophores or fluorophores leads to variations in the emission characteristics. Furthermore, this review article highlights the diverse range of applications for self-indicating polymers. These materials find particular use in sensing and monitoring applications, where their responsive nature enables them to act as sensors for specific analytes, environmental parameters, or mechanical stress. Self-indicating polymers have also been used in the development of smart materials, including stimuli-responsive coatings, drug delivery systems, food sensors, wearable devices, and molecular switches. The unique combination of tunable properties and responsiveness makes self-indicating polymers highly promising for future advancements in the fields of biotechnology, materials science, and electronics.
Collapse
Affiliation(s)
- Mobina Bayat
- Faculty of Polymer Engineering, Sahand University of Technology, P.O. Box: 51335-1996, Tabriz, Iran.
| | - Hanieh Mardani
- Faculty of Polymer Engineering, Sahand University of Technology, P.O. Box: 51335-1996, Tabriz, Iran.
| | - Hossein Roghani-Mamaqani
- Faculty of Polymer Engineering, Sahand University of Technology, P.O. Box: 51335-1996, Tabriz, Iran.
- Institute of Polymeric Materials, Sahand University of Technology, P.O. Box: 51335-1996, Tabriz, Iran
| | - Richard Hoogenboom
- Supramolecular Chemistry Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Faculty of Sciences, Ghent University, Krijgslaan 281, S4-bis, B-9000 Ghent, Belgium.
| |
Collapse
|
8
|
Cho Y, Lee W, Sin H, Oh S, Choi KC, Jun JH. Non-Invasive Alcohol Concentration Measurement Using a Spectroscopic Module: Outlook for the Development of a Drunk Driving Prevention System. SENSORS (BASEL, SWITZERLAND) 2024; 24:2252. [PMID: 38610464 PMCID: PMC11014244 DOI: 10.3390/s24072252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 01/08/2024] [Accepted: 01/08/2024] [Indexed: 04/14/2024]
Abstract
Alcohol acts as a central nervous system depressant and falls under the category of psychoactive drugs. It has the potential to impair vital bodily functions, including cognitive alertness, muscle coordination, and induce fatigue. Taking the wheel after consuming alcohol can lead to delayed responses in emergency situations and increases the likelihood of collisions with obstacles or suddenly appearing objects. Statistically, drivers under the influence of alcohol are seven times more likely to cause accidents compared to sober individuals. Various techniques and methods for alcohol measurement have been developed. The widely used breathalyzer, which requires direct contact with the mouth, raises concerns about hygiene. Methods like chromatography require skilled examiners, while semiconductor sensors exhibit instability in sensitivity over measurement time and has a short lifespan, posing structural challenges. Non-dispersive infrared analyzers face structural limitations, and in-vehicle air detection methods are susceptible to external influences, necessitating periodic calibration. Despite existing research and technologies, there remain several limitations, including sensitivity to external factors such as temperature, humidity, hygiene consideration, and the requirement for periodic calibration. Hence, there is a demand for a novel technology that can address these shortcomings. This study delved into the near-infrared wavelength range to investigate optimal wavelengths for non-invasively measuring blood alcohol concentration. Furthermore, we conducted an analysis of the optical characteristics of biological substances, integrated these data into a mathematical model, and demonstrated that alcohol concentration can be accurately sensed using the first-order modeling equation at the optimal wavelength. The goal is to minimize user infection and hygiene issues through a non-destructive and non-invasive method, while applying a compact spectrometer sensor suitable for button-type ignition devices in vehicles. Anticipated applications of this study encompass diverse industrial sectors, including the development of non-invasive ignition button-based alcohol prevention systems, surgeon's alcohol consumption status in the operating room, screening heavy equipment operators for alcohol use, and detecting alcohol use in close proximity to hazardous machinery within factories.
Collapse
Affiliation(s)
- Yechan Cho
- Department of Biomedical Engineering, Konkuk University, Chungju-si 27478, Chungcheongbuk-do, Republic of Korea; (Y.C.); (W.L.); (H.S.); (S.O.)
| | - Wonjune Lee
- Department of Biomedical Engineering, Konkuk University, Chungju-si 27478, Chungcheongbuk-do, Republic of Korea; (Y.C.); (W.L.); (H.S.); (S.O.)
| | - Heock Sin
- Department of Biomedical Engineering, Konkuk University, Chungju-si 27478, Chungcheongbuk-do, Republic of Korea; (Y.C.); (W.L.); (H.S.); (S.O.)
| | - Suseong Oh
- Department of Biomedical Engineering, Konkuk University, Chungju-si 27478, Chungcheongbuk-do, Republic of Korea; (Y.C.); (W.L.); (H.S.); (S.O.)
| | - Kyo Chang Choi
- Road Innovation Technology, Jincheon-gun 27856, Chungcheongbuk-do, Republic of Korea;
| | - Jae-Hoon Jun
- Department of Biomedical Engineering, Konkuk University, Chungju-si 27478, Chungcheongbuk-do, Republic of Korea; (Y.C.); (W.L.); (H.S.); (S.O.)
- Research Institute of Biomedical Engineering, Konkuk University, Chungju-si 27478, Chungcheongbuk-do, Republic of Korea
| |
Collapse
|
9
|
Wang X, Wang Z, Xiao M, Li Z, Zhu Z. Advances in biomedical systems based on microneedles: design, fabrication, and application. Biomater Sci 2024; 12:530-563. [PMID: 37971423 DOI: 10.1039/d3bm01551c] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Wearable devices have become prevalent in biomedical studies due to their convenient portability and potential utility in biomarker monitoring for healthcare. Accessing interstitial fluid (ISF) across the skin barrier, microneedle (MN) is a promising minimally invasive wearable technology for transdermal sensing and drug delivery. MN has the potential to overcome the limitations of conventional transdermal drug administration, making it another prospective mode of drug delivery after oral and injectable. Subsequently, combining MN with multiple sensing approaches has led to its extensive application to detect biomarkers in ISF. In this context, employing MN platforms and control schemes to merge diagnostic and therapeutic capabilities into theranostic systems will facilitate on-demand therapy and point-of-care diagnostics, paving the way for future MN technologies. A comprehensive analysis of the growing advances of microneedles in biomedical systems is presented in this review to summarize the latest studies for academics in the field and to offer for reference the issues that need to be addressed in MN application for healthcare. Covering an array of novel studies, we discuss the following main topics: classification of microneedles in the biomedical field, considerations of MN design, current applications of microneedles in diagnosis and therapy, and the regulatory landscape and prospects of microneedles for biomedical applications. This review sheds light on the significance of microneedle-based innovations, presenting an analysis of their potential implications and contributions to the community of wearable healthcare technologies. The review provides a comprehensive understanding of the field's current state and potential, making it a valuable resource for academics and clinicians seeking to harness the full potential of MN applications.
Collapse
Affiliation(s)
- Xinghao Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China.
| | - Zifeng Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China.
| | - Min Xiao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China.
| | - Zhanhong Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China.
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China.
| |
Collapse
|
10
|
Mir TUG, Wani AK, Akhtar N, Katoch V, Shukla S, Kadam US, Hong JC. Advancing biological investigations using portable sensors for detection of sensitive samples. Heliyon 2023; 9:e22679. [PMID: 38089995 PMCID: PMC10711145 DOI: 10.1016/j.heliyon.2023.e22679] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 09/29/2023] [Accepted: 11/16/2023] [Indexed: 01/14/2024] Open
Abstract
Portable biosensors are emerged as powerful diagnostic tools for analyzing intricately complex biological samples. These biosensors offer sensitive detection capabilities by utilizing biomolecules such as proteins, nucleic acids, microbes or microbial products, antibodies, and enzymes. Their speed, accuracy, stability, specificity, and low cost make them indispensable in forensic investigations and criminal cases. Notably, portable biosensors have been developed to rapidly detect toxins, poisons, body fluids, and explosives; they have proven invaluable in forensic examinations of suspected samples, generating efficient results that enable effective and fair trials. One of the key advantages of portable biosensors is their ability to provide sensitive and non-destructive detection of forensic samples without requiring extensive sample preparation, thereby reducing the possibility of false results. This comprehensive review provides an overview of the current advancements in portable biosensors for the detection of sensitive materials, highlighting their significance in advancing investigations and enhancing sensitive sample detection capabilities.
Collapse
Affiliation(s)
- Tahir ul Gani Mir
- School of Bioengineering and Biosciences, Lovely Professional University, Phagwara, Punjab, 144411, India
- State Forensic Science Laboratory, Srinagar, Jammu and Kashmir, 190001, India
| | - Atif Khurshid Wani
- School of Bioengineering and Biosciences, Lovely Professional University, Phagwara, Punjab, 144411, India
| | - Nahid Akhtar
- School of Bioengineering and Biosciences, Lovely Professional University, Phagwara, Punjab, 144411, India
| | - Vaidehi Katoch
- School of Bioengineering and Biosciences, Lovely Professional University, Phagwara, Punjab, 144411, India
| | - Saurabh Shukla
- School of Bioengineering and Biosciences, Lovely Professional University, Phagwara, Punjab, 144411, India
| | - Ulhas Sopanrao Kadam
- Division of Life Science and Division of Applied Life Science (BK21 Four), Plant Molecular Biology and Biotechnology Research Center, Gyeongsang National University, Jinju, Gyeongnam, 52828, South Korea
| | - Jong Chan Hong
- Division of Life Science and Division of Applied Life Science (BK21 Four), Plant Molecular Biology and Biotechnology Research Center, Gyeongsang National University, Jinju, Gyeongnam, 52828, South Korea
- Division of Plant Sciences, University of Missouri, Columbia, MO, 65211, USA
| |
Collapse
|
11
|
Kianersi S, Ludema C, Agley J, Ahn YY, Parker M, Ideker S, Rosenberg M. Development and validation of a model for measuring alcohol consumption from transdermal alcohol content data among college students. Addiction 2023; 118:2014-2025. [PMID: 37154154 PMCID: PMC11081732 DOI: 10.1111/add.16228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 04/20/2023] [Indexed: 05/10/2023]
Abstract
BACKGROUND AND AIMS Transdermal alcohol content (TAC) data collected by wearable alcohol monitors could potentially contribute to alcohol research, but raw data from the devices are challenging to interpret. We aimed to develop and validate a model using TAC data to detect alcohol drinking. DESIGN We used a model development and validation study design. SETTING Indiana, USA PARTICIPANTS: In March to April 2021, we enrolled 84 college students who reported drinking at least once a week (median age = 20 years, 73% white, 70% female). We observed participants' alcohol drinking behavior for 1 week. MEASUREMENTS Participants wore BACtrack Skyn monitors (TAC data), provided self-reported drinking start times in real time (smartphone app) and completed daily surveys about their prior day of drinking. We developed a model using signal filtering, peak detection algorithm, regression and hyperparameter optimization. The input was TAC and outputs were alcohol drinking frequency, start time and magnitude. We validated the model using daily surveys (internal validation) and data collected from college students in 2019 (external validation). FINDINGS Participants (N = 84) self-reported 213 drinking events. Monitors collected 10 915 hours of TAC. In internal validation, the model had a sensitivity of 70.9% (95% CI = 64.1%-77.0%) and a specificity of 73.9% (68.9%-78.5%) in detecting drinking events. The median absolute time difference between self-reported and model-detected drinking start times was 59 min. Mean absolute error (MAE) for the reported and detected number of drinks was 2.8 drinks. In an exploratory external validation among five participants, number of drinking events, sensitivity, specificity, median time difference and MAE were 15%, 67%, 100%, 45 minutes and 0.9 drinks, respectively. Our model's output was correlated with breath alcohol concentration data (Spearman's correlation [95% CI] = 0.88 [0.77, 0.94]). CONCLUSION This study, the largest of its kind to date, developed and validated a model for detecting alcohol drinking using transdermal alcohol content data collected with a new generation of alcohol monitors. The model and its source code are available as Supporting Information (https://osf.io/xngbk).
Collapse
Affiliation(s)
- Sina Kianersi
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, USA
- Channing Division of Network Medicine, Department of Medicine, Brigham and Women’s Hospital and Harvard Medical School, Boston, MA, USA
| | - Christina Ludema
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, USA
| | - Jon Agley
- Prevention Insights, Department of Applied Health Science, Indiana University School of Public Health-Bloomington, Bloomington, IN, USA
| | - Yong-Yeol Ahn
- Luddy School of Informatics, Computing, and Engineering, Indiana University, Bloomington, IN, USA
| | - Maria Parker
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, USA
| | - Sophie Ideker
- Epidemiology Department, Columbia University’s Mailman School of Public Health, New York City, NY, USA
| | - Molly Rosenberg
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, USA
| |
Collapse
|
12
|
Wang L, Xie ZL, Li X, Lynch VM, Mulfort KL. Optical detection of alcohols with a Cu(I)HETPHEN complex by reversible aldehyde to hemiacetal conversion. Analyst 2023; 148:4274-4278. [PMID: 37615298 DOI: 10.1039/d3an01005h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
A heteroleptic copper(I) bis(phenanthroline) complex with aldehyde groups at the 4,7 positions of the phenanthroline ligand was synthesized. The complex is responsive to alcohol, resulting in a distinct colour change caused by the facile reaction of the aldehyde group with alcohol, forming a hemiacetal product. The aldehyde species can be regenerated after heating the intermediate at 80 °C for 10 minutes, demonstrating the reusability of the complex for alcohol detection. This work presents a new strategy for applying transition metal complexes in small molecule sensing by installing functional groups in the secondary coordination sphere which reversibly react with analytes.
Collapse
Affiliation(s)
- Lei Wang
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai 200093, China.
- Division of Chemical Sciences and Engineering, Argonne National Laboratory, Lemont, IL 60439, USA.
| | - Zhu-Lin Xie
- Division of Chemical Sciences and Engineering, Argonne National Laboratory, Lemont, IL 60439, USA.
| | - Xin Li
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Vincent M Lynch
- Department of Chemistry, University of Texas Austin, Austin, TX, 78712, USA
| | - Karen L Mulfort
- Division of Chemical Sciences and Engineering, Argonne National Laboratory, Lemont, IL 60439, USA.
| |
Collapse
|
13
|
Rosenberg M, Kianersi S, Luetke M, Jozkowski K, Guerra-Reyes L, Shih PC, Finn P, Ludema C. Wearable alcohol monitors for alcohol use data collection among college students: Feasibility and acceptability. Alcohol 2023; 111:75-83. [PMID: 37295566 PMCID: PMC10527594 DOI: 10.1016/j.alcohol.2023.05.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 05/17/2023] [Accepted: 05/31/2023] [Indexed: 06/12/2023]
Abstract
OBJECTIVE We assessed the feasibility and acceptability of using BACtrack Skyn wearable alcohol monitors for alcohol research in a college student population. METHODS We enrolled n = 5 (Sample 1) and n = 84 (Sample 2) Indiana University undergraduate students to wear BACtrack Skyn devices continuously over a 5-day to 7-day study period. We assessed feasibility in both samples by calculating compliance with study procedures, and by analyzing amount and distributions of device output [e.g., transdermal alcohol content (TAC), temperature, motion]. In Sample 1, we assessed feasibility and acceptability with the Feasibility of Intervention Measure (FIM) scale and the Acceptability of Intervention Measure (AIM) scale. RESULTS All participants were able to successfully use the alcohol monitors, producing a total of 11,504 h of TAC data. TAC data were produced on 567 days of the 602 total possible days of data collection. The distribution of the TAC data showed between-person variation, as would be expected with between-person differences in drinking patterns. Temperature and motion data were also produced as expected. Sample 1 participants (n = 5) reported high feasibility and acceptability of the wearable alcohol monitors in survey responses with a mean FIM score of 4.3 (of 5.0 possible score) and mean AIM score of 4.3 (of 5.0 possible score). CONCLUSIONS The high feasibility and acceptability we observed underscore the promise of using BACtrack Skyn wearable alcohol monitors to improve our understanding of alcohol consumption among college students, a population at particularly high risk for alcohol-related harms.
Collapse
Affiliation(s)
- Molly Rosenberg
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, United States.
| | - Sina Kianersi
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, United States
| | - Maya Luetke
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, United States; University of Minnesota Institute for Social Research and Data Innovation, Minneapolis, MN, United States
| | - Kristen Jozkowski
- Department of Applied Health Science, Indiana University School of Public Health-Bloomington, Bloomington, IN, United States
| | - Lucia Guerra-Reyes
- Department of Applied Health Science, Indiana University School of Public Health-Bloomington, Bloomington, IN, United States
| | - Patrick C Shih
- Department of Informatics, Luddy School of Informatics, Computing, and Engineering, Indiana University-Bloomington, Bloomington, IN, United States
| | - Peter Finn
- Department of Psychological and Brain Sciences, Indiana University-Bloomington, Bloomington, IN, United States
| | - Christina Ludema
- Department of Epidemiology and Biostatistics, Indiana University School of Public Health-Bloomington, Bloomington, IN, United States
| |
Collapse
|
14
|
Qureshi A, Niazi JH. Graphene-interfaced flexible and stretchable micro-nano electrodes: from fabrication to sweat glucose detection. MATERIALS HORIZONS 2023; 10:1580-1607. [PMID: 36880340 DOI: 10.1039/d2mh01517j] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Flexible and stretchable wearable electronic devices have received tremendous attention for their non-invasive and personal health monitoring applications. These devices have been fabricated by integrating flexible substrates and graphene nanostructures for non-invasive detection of physiological risk biomarkers from human bodily fluids, such as sweat, and monitoring of human physical motion tracking parameters. The extraordinary properties of graphene nanostructures in fully integrated wearable devices have enabled improved sensitivity, electronic readouts, signal conditioning and communication, energy harvesting from power sources through electrode design and patterning, and graphene surface modification or treatment. This review explores advances made toward the fabrication of graphene-interfaced wearable sensors, flexible and stretchable conductive graphene electrodes, as well as their potential applications in electrochemical sensors and field-effect-transistors (FETs) with special emphasis on monitoring sweat biomarkers, mainly in glucose-sensing applications. The review emphasizes flexible wearable sweat sensors and provides various approaches thus far employed for the fabrication of graphene-enabled conductive and stretchable micro-nano electrodes, such as photolithography, electron-beam evaporation, laser-induced graphene designing, ink printing, chemical-synthesis and graphene surface modification. It further explores existing graphene-interfaced flexible wearable electronic devices utilized for sweat glucose sensing, and their technological potential for non-invasive health monitoring applications.
Collapse
Affiliation(s)
- Anjum Qureshi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla, 34956, Istanbul, Turkey.
| | - Javed H Niazi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla, 34956, Istanbul, Turkey.
| |
Collapse
|
15
|
Courtney JB, Russell MA, Conroy DE. Acceptability and validity of using the BACtrack skyn wrist-worn transdermal alcohol concentration sensor to capture alcohol use across 28 days under naturalistic conditions - A pilot study. Alcohol 2023; 108:30-43. [PMID: 36473634 PMCID: PMC10413177 DOI: 10.1016/j.alcohol.2022.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 11/09/2022] [Accepted: 11/30/2022] [Indexed: 12/12/2022]
Abstract
Wrist-worn transdermal alcohol concentration (TAC) sensors have the potential to provide detailed information about day-level features of alcohol use but have rarely been used in field-based research or in early adulthood (i.e., 26-40 years) alcohol users. This pilot study assessed the acceptability, user burden, and validity of using the BACtrack Skyn across 28 days in individuals' natural settings. Adults aged 26-37 (N = 11, Mage = 31.2, 55% female, 73% non-Hispanic white) participated in a study including retrospective surveys, a 28-day field protocol wearing Skyn and SCRAM sensors and completing ecological momentary assessments (EMA) of alcohol use and duration (daily morning reports and participant-initiated start/stop drinking EMAs), and follow-up interviews. Day-level features of alcohol use extracted from self-reports and/or sensors included drinks consumed, estimated Blood Alcohol Concentration (eBAC), drinking duration, peak TAC, area under the curve (AUC), rise rate, and fall rate. Repeated-measures correlations (rrm) tested within-person associations between day-level features of alcohol use from the Skyn versus self-report or the SCRAM. Participants preferred wearing the Skyn over the SCRAM [t (10) = -6.79, p < .001, d = 2.74]. Skyn data were available for 5614 (74.2%) out of 7566 h, with 20.7% of data lost due to syncing/charging issues and 5.1% lost due to device removal. Skyn agreement for detecting drinking days was 55.5% and 70.3% when compared to self-report and the SCRAM, respectively. Correlations for drinking intensity between self-report and the Skyn were 0.35 for peak TAC, 0.52 for AUC, and 0.30 for eBAC, which were smaller than correlations between self-report and SCRAM, at 0.78 for peak TAC, 0.79 for AUC, and 0.61 for eBAC. Correlations for drinking duration were larger when comparing self-report to the Skyn (rrm = 0.36) versus comparing self-report to the SCRAM (rrm = 0.31). The Skyn showed moderate-to-large, significant correlations with the SCRAM for peak TAC (rrm = 0.54), AUC (rrm = 0.80), and drinking duration (rrm = 0.63). Our findings support the acceptability and validity of using the Skyn for assessing alcohol use across an extended time frame (i.e., 28 days) in individuals' natural settings, and for providing useful information about day-level features of alcohol use.
Collapse
Affiliation(s)
- Jimikaye B Courtney
- College of Health and Human Development, Pennsylvania State University, University Park, Pennsylvania, 16802, United States.
| | - Michael A Russell
- College of Health and Human Development, Pennsylvania State University, University Park, Pennsylvania, 16802, United States
| | - David E Conroy
- College of Health and Human Development, Pennsylvania State University, University Park, Pennsylvania, 16802, United States
| |
Collapse
|
16
|
van Egmond K, Riordan B, Wright CJC, Livingston M, Kuntsche E. Measurement of Transdermal Alcohol Concentration using a Wrist Worn Enzymatic Transdermal Monitor. Alcohol 2023; 110:33-40. [PMID: 37105335 DOI: 10.1016/j.alcohol.2023.03.162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 03/16/2023] [Accepted: 03/17/2023] [Indexed: 04/29/2023]
Abstract
BACKGROUND New-generation transdermal monitors such as the ION Research Alpha Prototypes (ION RAP) hold promise for real-time alcohol measurement, with improvements in design features such as sampling frequency, size and comfort. This paper aims to provide the first comparisons of the wrist worn enzyme-based ION RAP and the fuel-cell based SCRAM-CAM against breath alcohol concentration (BrAC) readings. METHODS Participants (N=23) completed a total of 69 laboratory alcohol administration sessions, while wearing both a prototype of the ION RAP wristband and a SCRAM-CAM ankle monitor; they also gave breath samples each 10 minutes. Analyses focused on latencies of transdermal alcohol concentration (TAC) after alcohol ingestion, correlations, and cross-correlations between BrAC and TAC measurements. RESULTS A high failure rate of the ION RAP was observed (61.5% of the sessions were excluded due to the sessions not containing enough valid data). On average, the SCRAM-CAM and ION RAP detected alcohol 43 (SD=21) and 50 (SD=27) minutes after the first drink, with peak values reached after 138 (SD=47) and 154 (SD=56) minutes, respectively. SCRAM-CAM TAC peak (r=0.185,p=0.375) and area under the curve (AUC; r=0.320, p=0.118) showed small- and medium-sized correlations to BrAC. ION RAP TAC peak (r=-0.082, p=0.698) and AUC (r=0.040, p=0.852) correlations to BrAC were close to zero. CONCLUSIONS In this study, the new-generation ION RAP and the traditionally used SCRAM-CAM show similar delays in detection and similar TAC curves over time, despite using either enzyme or fuel-cell based technologies, respectively. Due to high failure rates of the ION RAP prototypes and close to zero correlations to BrAC, further developments and improvements of these TAC wristbands are required for reliable and valid use in real-time alcohol measurement.
Collapse
Affiliation(s)
- Kelly van Egmond
- Centre for Alcohol Policy and Research (CAPR), NR1 Building, La Trobe University, Melbourne, 3086 VIC, Australia
| | - Benjamin Riordan
- Centre for Alcohol Policy and Research (CAPR), NR1 Building, La Trobe University, Melbourne, 3086 VIC, Australia
| | - Cassandra J C Wright
- Centre for Alcohol Policy and Research (CAPR), NR1 Building, La Trobe University, Melbourne, 3086 VIC, Australia; Menzies School of Health Research, Charles Darwin University, Darwin, Australia; Burnet Institute, Melbourne, Australia
| | - Michael Livingston
- Centre for Alcohol Policy and Research (CAPR), NR1 Building, La Trobe University, Melbourne, 3086 VIC, Australia; Faculty of Health Sciences, Curtin University, Melbourne, Australia; Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Emmanuel Kuntsche
- Centre for Alcohol Policy and Research (CAPR), NR1 Building, La Trobe University, Melbourne, 3086 VIC, Australia; Institute of Psychology, Eötvös Loránd University, Kazinczy u. 23-27, 1075 Budapest, Hungary.
| |
Collapse
|
17
|
Gao F, Liu C, Zhang L, Liu T, Wang Z, Song Z, Cai H, Fang Z, Chen J, Wang J, Han M, Wang J, Lin K, Wang R, Li M, Mei Q, Ma X, Liang S, Gou G, Xue N. Wearable and flexible electrochemical sensors for sweat analysis: a review. MICROSYSTEMS & NANOENGINEERING 2023; 9:1. [PMID: 36597511 PMCID: PMC9805458 DOI: 10.1038/s41378-022-00443-6] [Citation(s) in RCA: 146] [Impact Index Per Article: 73.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 07/26/2022] [Accepted: 08/10/2022] [Indexed: 06/10/2023]
Abstract
Flexible wearable sweat sensors allow continuous, real-time, noninvasive detection of sweat analytes, provide insight into human physiology at the molecular level, and have received significant attention for their promising applications in personalized health monitoring. Electrochemical sensors are the best choice for wearable sweat sensors due to their high performance, low cost, miniaturization, and wide applicability. Recent developments in soft microfluidics, multiplexed biosensing, energy harvesting devices, and materials have advanced the compatibility of wearable electrochemical sweat-sensing platforms. In this review, we summarize the potential of sweat for medical detection and methods for sweat stimulation and collection. This paper provides an overview of the components of wearable sweat sensors and recent developments in materials and power supply technologies and highlights some typical sensing platforms for different types of analytes. Finally, the paper ends with a discussion of the challenges and a view of the prospective development of this exciting field.
Collapse
Affiliation(s)
- Fupeng Gao
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Chunxiu Liu
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Lichao Zhang
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Tiezhu Liu
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Zheng Wang
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Zixuan Song
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Haoyuan Cai
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Zhen Fang
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Jiamin Chen
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Junbo Wang
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Mengdi Han
- Department of Biomedical Engineering, College of Future Technology, Peking University, 100871 Beijing, China
| | - Jun Wang
- Beijing Shuimujiheng Biotechnology Company, 101102 Beijing, China
| | - Kai Lin
- PLA Air Force Characteristic Medical Center, 100142 Beijing, China
| | - Ruoyong Wang
- PLA Air Force Characteristic Medical Center, 100142 Beijing, China
| | - Mingxiao Li
- Institute of Microelectronics of the Chinese Academy of Sciences, 100029 Beijing, China
| | - Qian Mei
- CAS Key Laboratory of Biomedical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences (CAS), 215163 Suzhou, China
| | - Xibo Ma
- CBSR&NLPR, Institute of Automation, Chinese Academy of Sciences, Beijing, China
| | - Shuli Liang
- Functional Neurosurgery Department, Beijing Children’s Hospital, Capital Medical University, 100045 Beijing, China
| | - Guangyang Gou
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| | - Ning Xue
- School of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), 100190 Beijing, China
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, 100190 Beijing, China
| |
Collapse
|
18
|
Janghorban M, Aradanas I, Kazemi S, Ngaju P, Pandey R. Recent Advances, Opportunities, and Challenges in Developing Nucleic Acid Integrated Wearable Biosensors for Expanding the Capabilities of Wearable Technologies in Health Monitoring. BIOSENSORS 2022; 12:986. [PMID: 36354495 PMCID: PMC9688223 DOI: 10.3390/bios12110986] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/30/2022] [Accepted: 11/04/2022] [Indexed: 06/16/2023]
Abstract
Wearable biosensors are becoming increasingly popular due to the rise in demand for non-invasive, real-time monitoring of health and personalized medicine. Traditionally, wearable biosensors have explored protein-based enzymatic and affinity-based detection strategies. However, in the past decade, with the success of nucleic acid-based point-of-care diagnostics, a paradigm shift has been observed in integrating nucleic acid-based assays into wearable sensors, offering better stability, enhanced analytical performance, and better clinical applicability. This narrative review builds upon the current state and advances in utilizing nucleic acid-based assays, including oligonucleotides, nucleic acid, aptamers, and CRISPR-Cas, in wearable biosensing. The review also discusses the three fundamental blocks, i.e., fabrication requirements, biomolecule integration, and transduction mechanism, for creating nucleic acid integrated wearable biosensors.
Collapse
Affiliation(s)
- Mohammad Janghorban
- Department of Biomedical Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Irvyne Aradanas
- Department of Biomedical Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Sara Kazemi
- Department of Biomedical Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Philippa Ngaju
- Department of Biomedical Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Richa Pandey
- Department of Biomedical Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
- Hotchkiss Brain Institute, University of Calgary, Calgary, AB T2N 1N4, Canada
| |
Collapse
|
19
|
Zaytsev V, Ermatov TI, Fedorov FS, Balabin N, Kapralov PO, Bondareva JV, Ignatyeva DO, Khlebtsov BN, Kosolobov SS, Belotelov VI, Nasibulin AG, Gorin DA. Design of an Artificial Opal/Photonic Crystal Interface for Alcohol Intoxication Assessment: Capillary Condensation in Pores and Photonic Materials Work Together. Anal Chem 2022; 94:12305-12313. [PMID: 36027051 DOI: 10.1021/acs.analchem.2c00573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Alcohol intoxication has a dangerous effect on human health and is often associated with a risk of catastrophic injuries and alcohol-related crimes. A demand to address this problem adheres to the design of new sensor systems for the real-time monitoring of exhaled breath. We introduce a new sensor system based on a porous hydrophilic layer of submicron silica particles (SiO2 SMPs) placed on a one-dimensional photonic crystal made of Ta2O5/SiO2 dielectric layers whose operation relies on detecting changes in the position of surface wave resonance during capillary condensation in pores. To make the active layer of SiO2 SMPs, we examine the influence of electrostatic interactions of media, particles, and the surface of the crystal influenced by buoyancy, gravity force, and Stokes drag force in the frame of the dip-coating preparation method. We evaluate the sensing performance toward biomarkers such as acetone, ammonia, ethanol, and isopropanol and test sensor system capabilities for alcohol intoxication assessment. We have found this sensor to respond to all tested analytes in a broad range of concentrations. By processing the sensor signals by principal component analysis, we selectively determined the analytes. We demonstrated the excellent performance of our device for alcohol intoxication assessment in real-time.
Collapse
Affiliation(s)
- Valeriy Zaytsev
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| | - Timur I Ermatov
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| | - Fedor S Fedorov
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| | - Nikita Balabin
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| | - Pavel O Kapralov
- Russian Quantum Centre, 30 bld. 1 Bolshoy Boulevard, Moscow 121205, Russia
| | - Julia V Bondareva
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| | - Daria O Ignatyeva
- Russian Quantum Centre, 30 bld. 1 Bolshoy Boulevard, Moscow 121205, Russia.,Lomonosov Moscow State University, Faculty of Physics, Leninskie Gory, Moscow 119991, Russia
| | - Boris N Khlebtsov
- Institute of Biochemistry and Physiology of Plants and Microorganisms, 13 Prospekt Entuziastov, Saratov 410049, Russia.,Saratov State University, 83 Astrakhanskaya Street, Saratov 410012, Russia
| | - Sergey S Kosolobov
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| | - Vladimir I Belotelov
- Russian Quantum Centre, 30 bld. 1 Bolshoy Boulevard, Moscow 121205, Russia.,Lomonosov Moscow State University, Faculty of Physics, Leninskie Gory, Moscow 119991, Russia
| | - Albert G Nasibulin
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia.,Aalto University, Kemistintie 1, P.O. Box 16100, Aalto 00076, Finland
| | - Dmitry A Gorin
- Skolkovo Institute of Science and Technology, 3 Nobel Street, Moscow 121205, Russia
| |
Collapse
|
20
|
An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid. Nat Biomed Eng 2022; 6:1214-1224. [PMID: 35534575 DOI: 10.1038/s41551-022-00887-1] [Citation(s) in RCA: 226] [Impact Index Per Article: 75.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 03/25/2022] [Indexed: 12/16/2022]
Abstract
Implementations of wearable microneedle-based arrays of sensors for the monitoring of multiple biomarkers in interstitial fluid have lacked system integration and evidence of robust analytical performance. Here we report the development and testing of a fully integrated wearable array of microneedles for the wireless and continuous real-time sensing of two metabolites (lactate and glucose, or alcohol and glucose) in the interstitial fluid of volunteers performing common daily activities. The device works with a custom smartphone app for data capture and visualization, comprises reusable electronics and a disposable microneedle array, and is optimized for system integration, cost-effective fabrication via advanced micromachining, easier assembly, biocompatibility, pain-free skin penetration and enhanced sensitivity. Single-analyte and dual-analyte measurements correlated well with the corresponding gold-standard measurements in blood or breath. Further validation of the technology in large populations with concurrent validation of sensor readouts through centralized laboratory tests should determine the robustness and utility of real-time simultaneous monitoring of several biomarkers in interstitial fluid.
Collapse
|
21
|
A Review on Flexible Electrochemical Biosensors to Monitor Alcohol in Sweat. BIOSENSORS 2022; 12:bios12040252. [PMID: 35448313 PMCID: PMC9026542 DOI: 10.3390/bios12040252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/05/2022] [Accepted: 04/06/2022] [Indexed: 11/17/2022]
Abstract
The continued focus on improving the quality of human life has encouraged the development of increasingly efficient, durable, and cost-effective products in healthcare. Over the last decade, there has been substantial development in the field of technical and interactive textiles that combine expertise in electronics, biology, chemistry, and physics. Most recently, the creation of textile biosensors capable of quantifying biometric data in biological fluids is being studied, to detect a specific disease or the physical condition of an individual. The ultimate goal is to provide access to medical diagnosis anytime and anywhere. Presently, alcohol is considered the most commonly used addictive substance worldwide, being one of the main causes of death in road accidents. Thus, it is important to think of solutions capable of minimizing this public health problem. Alcohol biosensors constitute an excellent tool to aid at improving road safety. Hence, this review explores concepts about alcohol biomarkers, the composition of human sweat and the correlation between alcohol and blood. Different components and requirements of a biosensor are reviewed, along with the electrochemical techniques to evaluate its performance, in addition to construction techniques of textile-based biosensors. Special attention is given to the determination of biomarkers that must be low cost and fast, so the use of biomimetic materials to recognize and detect the target analyte is turning into an attractive option to improve electrochemical behavior.
Collapse
|
22
|
Brobbin E, Deluca P, Hemrage S, Drummond C. Accuracy of Wearable Transdermal Alcohol Sensors: Systematic Review. J Med Internet Res 2022; 24:e35178. [PMID: 35436239 PMCID: PMC9052024 DOI: 10.2196/35178] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/03/2022] [Accepted: 02/19/2022] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND There are a range of wearable transdermal alcohol sensors that are available and are being developed. These devices have the potential to monitor alcohol consumption continuously over extended periods in an objective manner, overcoming some of the limitations of other alcohol measurement methods (blood, breath, and urine). OBJECTIVE The objective of our systematic review was to assess wearable transdermal alcohol sensor accuracy. METHODS A systematic search of the CINAHL, Embase, Google Scholar, MEDLINE, PsycINFO, PubMed, and Scopus bibliographic databases was conducted in February 2021. In total, 2 team members (EB and SH) independently screened studies for inclusion, extracted data, and assessed the risk of bias. The methodological quality of each study was appraised using the Mixed Methods Appraisal Tool. The primary outcome was transdermal alcohol sensor accuracy. The data were presented as a narrative synthesis. RESULTS We identified and analyzed 32 studies. Study designs included laboratory, ambulatory, and mixed designs, as well as randomized controlled trials; the length of time for which the device was worn ranged from days to weeks; and the analyzed sample sizes ranged from 1 to 250. The results for transdermal alcohol concentration data from various transdermal alcohol sensors were generally found to positively correlate with breath alcohol concentration, blood alcohol concentration, and self-report (moderate to large correlations). However, there were some discrepancies between study reports; for example, WrisTAS sensitivity ranged from 24% to 85.6%, and specificity ranged from 67.5% to 92.94%. Higher malfunctions were reported with the BACtrack prototype (16%-38%) and WrisTAS (8%) than with SCRAM (2%); however, the former devices also reported a reduced time lag for peak transdermal alcohol concentration values when compared with SCRAM. It was also found that many companies were developing new models of wearable transdermal alcohol sensors. CONCLUSIONS As shown, there is a lack of consistency in the studies on wearable transdermal alcohol sensor accuracy regarding study procedures and analyses of findings, thus making it difficult to draw direct comparisons between them. This needs to be considered in future research, and there needs to be an increase in studies directly comparing different transdermal alcohol sensors. There is also a lack of research investigating the accuracy of transdermal alcohol sensors as a tool for monitoring alcohol consumption in clinical populations and use over extended periods. Although there is some preliminary evidence suggesting the accuracy of these devices, this needs to be further investigated in clinical populations. TRIAL REGISTRATION PROSPERO CRD42021231027; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=231027.
Collapse
Affiliation(s)
- Eileen Brobbin
- Department of Addictions, King's College London, London, United Kingdom
| | - Paolo Deluca
- Department of Addictions, King's College London, London, United Kingdom
| | - Sofia Hemrage
- Department of Addictions, King's College London, London, United Kingdom
| | - Colin Drummond
- Department of Addictions, King's College London, London, United Kingdom
| |
Collapse
|
23
|
|
24
|
Russell MA, Turrisi RJ, Smyth JM. Transdermal sensor features correlate with ecological momentary assessment drinking reports and predict alcohol-related consequences in young adults' natural settings. Alcohol Clin Exp Res 2022; 46:100-113. [PMID: 35066894 PMCID: PMC8830764 DOI: 10.1111/acer.14739] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 10/28/2021] [Accepted: 11/04/2021] [Indexed: 01/25/2023]
Abstract
BACKGROUND Wearable transdermal alcohol concentration (TAC) sensors allow passive monitoring of alcohol concentration in natural settings and measurement of multiple features from drinking episodes, including peak intoxication level, speed of intoxication (absorption rate) and elimination, and duration. These passively collected features extend commonly used self-reported drink counts and may facilitate the prediction of alcohol-related consequences in natural settings, aiding risk stratification and prevention efforts. METHOD A total of 222 young adults aged 21-29 (M age = 22.3, 64% female, 79% non-Hispanic white, 84% undergraduates) who regularly drink heavily participated in a 5-day study that included the ecological momentary assessment (EMA) of alcohol consumption (daily morning reports and participant-initiated episodic EMA sequences) and the wearing of TAC sensors (SCRAM-CAM anklets). The analytic sample contained 218 participants and 1274 days (including 554 self-reported drinking days). Five features-area under the curve (AUC), peak TAC, rise rate (rate of absorption), fall rate (rate of elimination), and duration-were extracted from TAC-positive trajectories for each drinking day. Day- and person-level associations of TAC features with drink counts (morning and episodic EMA) and alcohol-related consequences were tested using multilevel modeling. RESULTS TAC features were strongly associated with morning drink reports (r = 0.6-0.7) but only moderately associated with episodic EMA drink counts (r = 0.3-0.5) at both day and person levels. Higher peaks, larger AUCs, faster rise rates, and faster fall rates were significantly predictive of day-level alcohol-related consequences after adjusting for both morning and episodic EMA drink counts in separate models. Person means of TAC features added little above daily scores to the prediction of alcohol-related consequences. CONCLUSIONS These results support the utility of TAC sensors in studies of alcohol misuse among young adults in natural settings and outline the specific TAC features that contribute to the day-level prediction of alcohol-related consequences. TAC sensors provide a passive option for obtaining valid and unique information predictive of drinking risk in natural settings.
Collapse
Affiliation(s)
- Michael A. Russell
- Department of Biobehavioral Health The Pennsylvania State University University Park Pennsylvania USA
| | - Robert J. Turrisi
- Department of Biobehavioral Health The Pennsylvania State University University Park Pennsylvania USA
| | - Joshua M. Smyth
- Department of Biobehavioral Health The Pennsylvania State University University Park Pennsylvania USA
| |
Collapse
|
25
|
Zhong B, Jiang K, Wang L, Shen G. Wearable Sweat Loss Measuring Devices: From the Role of Sweat Loss to Advanced Mechanisms and Designs. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2103257. [PMID: 34713981 PMCID: PMC8728835 DOI: 10.1002/advs.202103257] [Citation(s) in RCA: 57] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/15/2021] [Indexed: 05/22/2023]
Abstract
Wearable sweat sensors have received significant research interest and have become popular as sweat contains considerable health information about physiological and psychological states. However, measured biomarker concentrations vary with sweat rates, which has a significant effect on the accuracy and reliability of sweat biosensors. Wearable sweat loss measuring devices (SLMDs) have recently been proposed to overcome the limitations of biomarker tracking and reduce inter- and intraindividual variability. In addition, they offer substantial potential for monitoring human body homeostasis, because sweat loss plays an indispensable role in thermoregulation and skin hydration. Previous studies have not carried out a comprehensive and systematic review of the principles, importance, and development of wearable SLMDs. This paper reviews wearable SLMDs with a new health perspective from the role of sweat loss to advanced mechanisms and designs. Two types of sweat and their measurement significance for practical applications are highlighted. Then, a comprehensive review of advances in different wearable SLMDs based on hygrometers, absorbent materials, and microfluidics is presented by describing their respective device architectures, present situations, and future directions. Finally, concluding remarks on opportunities for future application fields and challenges for future sweat sensing are presented.
Collapse
Affiliation(s)
- Bowen Zhong
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Kai Jiang
- Faculty of Hepato-Pancreato-Biliary Surgery, Chinese PLA General Hospital, Institute of Hepatobiliary Surgery of Chinese PLA, Key Laboratory of Digital Hepatobiliary Surgery, Chinese PLA, Beijing, 100853, China
| | - Lili Wang
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Guozhen Shen
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| |
Collapse
|
26
|
Garett R, Young SD. Digital Public Health Surveillance Tools for Alcohol Use and HIV Risk Behaviors. AIDS Behav 2021; 25:333-338. [PMID: 33730254 PMCID: PMC7966886 DOI: 10.1007/s10461-021-03221-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/08/2021] [Indexed: 11/25/2022]
Abstract
There is a need for real-time and predictive data on alcohol use both broadly and specific to HIV. However, substance use and HIV data often suffer from lag times in reporting as they are typically measured from surveys, clinical case visits and other methods requiring extensive time for collection and analysis. Social big data might help to address this problem and be used to provide near real-time assessments of people's alcohol use and/or alcohol. This manuscript describes three types of social data sources (i.e., social media data, internet search data, and wearable device data) that might be used in surveillance of alcohol and HIV, and then discusses the implications and potential of implementing them as additional tools for public health surveillance.
Collapse
Affiliation(s)
- Renee Garett
- ElevateU, LLC; and Department of Informatics, University of California, Irvine, CA, USA
| | - Sean D Young
- Department of Emergency Medicine, University of California, Irvine, Irvine, CA, USA.
- University of California Institute for Prediction Technology, Department of Informatics, University of California, Irvine, Bren Hall, Irvine, CA, 6091, USA.
| |
Collapse
|
27
|
Wang H, Sheng T, Zhao S, Zheng Y, Yu J, Zhang Y, Gu Z. Recent advances in transdermal sensors for glucose monitoring. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021. [DOI: 10.1016/j.cobme.2021.100326] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
28
|
Yang B, Jiang X, Fang X, Kong J. Wearable chem-biosensing devices: from basic research to commercial market. LAB ON A CHIP 2021; 21:4285-4310. [PMID: 34672310 DOI: 10.1039/d1lc00438g] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Wearable chem-biosensors have been garnering tremendous interest due to the significant potential in tailored healthcare diagnostics and therapeutics. With the development of the medical diagnostics revolution, wearable chem-biosensors as a rapidly emerging wave allow individuals to perform on-demand detection and obtain the required in-depth information. In contrast to commercial wearables, which tend to be miniaturized for measuring physical activities, the recent progressive wearable chem-biosensing device have mainly focused on non-invasive or minimally invasive monitoring biomarkers at the molecular level. Wearables is a multidisciplinary subject, and chem-biosensing is one of the most significant technologies. In this review, the currently basic academic research of wearable chem-biosensing devices and its commercial transformation were summarized and highlighted. Moreover, some representative wearable products on the market for individual health managements are presented. Strategies for the identification and sensing of biomarkers are discussed to further promote the development of wearable chem-biosensing devices. We also shared the limitations and breakthroughs of the next generation of chemo-biosensor wearables, from home use to clinical diagnosis.
Collapse
Affiliation(s)
- Bin Yang
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, 200433, P. R. China.
| | - Xingyu Jiang
- Department of Biomedical Engineering, Shenzhen Bay Laboratory, Southern University of Science and Technology, Shenzhen, 518055, P. R. China.
| | - Xueen Fang
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, 200433, P. R. China.
| | - Jilie Kong
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, 200433, P. R. China.
| |
Collapse
|
29
|
Bukkitgar SD, Shetti NP, Aminabhavi TM. Electrochemical investigations for COVID-19 detection-A comparison with other viral detection methods. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2021; 420:127575. [PMID: 33162783 PMCID: PMC7605744 DOI: 10.1016/j.cej.2020.127575] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 10/07/2020] [Accepted: 10/26/2020] [Indexed: 05/02/2023]
Abstract
Virus-induced infection such as SARS-CoV-2 is a serious threat to human health and the economic setback of the world. Continued advances in the development of technologies are required before the viruses undergo mutation. The low concentration of viruses in environmental samples makes the detection extremely challenging; simple, accurate and rapid detection methods are in urgent need. Of all the analytical techniques, electrochemical methods have the established capabilities to address the issues. Particularly, the integration of nanotechnology would allow miniature devices to be made available at the point-of-care. This review outlines the capabilities of electrochemical methods in conjunction with nanotechnology for the detection of SARS-CoV-2. Future directions and challenges of the electrochemical biosensors for pathogen detection are covered including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, and reusable biosensors for on-site monitoring, thereby providing low-cost and disposable biosensors.
Collapse
Key Words
- AIV H5N1, Avian influenza
- AIV, Avian influenza virus
- ASFV, African swine fever virus
- BVDV, Bovine viral diarrhea virus
- CGV, Chikungunya viruses
- CMV, Cucumber mosaic virus
- COVID-19
- CSFV, Classic swine fever virus
- CV, Cyclic voltammetry
- DAstV-1, Duck astrovirus 1
- DAstV-2, Duck astrovirus 2
- DENV, Dengue virus
- DEV, Duck enteritis virus
- DHAV-1, Duck hepatitis A virus 1
- DHAV-3, Duck hepatitis A virus 3
- DPV, Differential pulse voltammetry
- DRV-1, Duck reovirus 1
- DRV-2, Duck reovirus 2
- Detection
- EBV, Epstein-Barr virus
- EIS, Electric impedance spectroscopy
- EPC, External positive controls
- EV, Human enterovirus
- EV71, Human enterovirus 71
- Electrochemical sensor
- FMI SMOF, Fluorescence molecularly imprinted sensor based on a metal–organic framework
- GCE, Glassy carbon electrode
- GCFaV-1, Ginger chlorotic fleck associated virus 1
- GCFaV-2, Ginger chlorotic fleck-associated virus 2
- GEV VN-96, Gastroenteritis virus VN-96
- GPV, Goose parvovirus
- HHV, Human herpes virus 6
- HIAV, Human influenza A viruses
- HPB19, Human parvovirus B19
- HSV, Herpes simplex
- IAV, influenza A virus
- IEA, Interdigitated electrode array
- IMA, Interdigitated microelectrode array
- INAA, Isothermal nucleic acid amplification-based
- JEV, Japanese encephalitis virus
- LAMP, Loop-Mediated Isothermal Amplification
- LSV, Linear sweep voltammetry
- MERS, Middle East respiratory syndrome
- MIEC, Molecularly imprinted electrochemiluminescence
- MNV, Murine norovirus
- MeV, Measles virus
- NNV, Nervous necrosis virus
- Nanotechnology
- PBoV, Porcine bocavirus
- PCNAME, Pt-coated nanostructured alumina membrane electrode
- PCR
- PCRLFS, Polymerase Chain Reaction with a lateral flow strip with a lateral flow strip
- PCV, Porcine circovirus 3
- PEDV, Porcine epidemic diarrhoea virus
- PRRSV, porcine reproductive and respiratory syndrome virus
- PSV, Pseudorabies virus
- RCA, Rolling circle amplification
- RGO, Reduced graphene oxide
- RT-LAMP-VF, RT-LAMP and a vertical flow visualization strip
- RV, Rubella virus
- SARS, Severe acute respiratory syndrome
- SIVH1N1, Swine influenza virus
- SWV, Square wave voltammetry
- TGEV, transmissible gastroenteritis coronavirus
- TMUV, Tembusu virus
- USEGFET, Ultra-sensitive electrolyte-gated field-effect transistor
- VZV, Varicella-zoster virus
- VZV, varicella-Zoster virus
- Viruses
- ZV, Zika virus
Collapse
Affiliation(s)
- Shikandar D Bukkitgar
- Centre for Electrochemical Science and Materials, Department of Chemistry, K.L.E. Institute of Technology, Gokul, Hubballi 580030, Karnataka, India
| | - Nagaraj P Shetti
- Centre for Electrochemical Science and Materials, Department of Chemistry, K.L.E. Institute of Technology, Gokul, Hubballi 580030, Karnataka, India
| | - Tejraj M Aminabhavi
- Pharmaceutical Engineering, Soniya College of Pharmacy, Dharwad 580-007, India
| |
Collapse
|
30
|
Gullapalli BT, Carreiro S, Chapman BP, Ganesan D, Sjoquist J, Rahman T. OpiTrack: A Wearable-based Clinical Opioid Use Tracker with Temporal Convolutional Attention Networks. PROCEEDINGS OF THE ACM ON INTERACTIVE, MOBILE, WEARABLE AND UBIQUITOUS TECHNOLOGIES 2021; 5. [PMID: 35291374 DOI: 10.1145/3478107] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Opioid use disorder is a medical condition with major social and economic consequences. While ubiquitous physiological sensing technologies have been widely adopted and extensively used to monitor day-to-day activities and deliver targeted interventions to improve human health, the use of these technologies to detect drug use in natural environments has been largely underexplored. The long-term goal of our work is to develop a mobile technology system that can identify high-risk opioid-related events (i.e., development of tolerance in the setting of prescription opioid use, return-to-use events in the setting of opioid use disorder) and deploy just-in-time interventions to mitigate the risk of overdose morbidity and mortality. In the current paper, we take an initial step by asking a crucial question: Can opioid use be detected using physiological signals obtained from a wrist-mounted sensor? Thirty-six individuals who were admitted to the hospital for an acute painful condition and received opioid analgesics as part of their clinical care were enrolled. Subjects wore a noninvasive wrist sensor during this time (1-14 days) that continuously measured physiological signals (heart rate, skin temperature, accelerometry, electrodermal activity, and interbeat interval). We collected a total of 2070 hours (≈ 86 days) of physiological data and observed a total of 339 opioid administrations. Our results are encouraging and show that using a Channel-Temporal Attention TCN (CTA-TCN) model, we can detect an opioid administration in a time-window with an F1-score of 0.80, a specificity of 0.77, sensitivity of 0.80, and an AUC of 0.77. We also predict the exact moment of administration in this time-window with a normalized mean absolute error of 8.6% and R 2 coefficient of 0.85.
Collapse
Affiliation(s)
| | - Stephanie Carreiro
- Division of Medical Toxicology, Department of Emergency Medicine University of Massachusetts Medical School, USA
| | - Brittany P Chapman
- Division of Medical Toxicology, Department of Emergency Medicine University of Massachusetts Medical School, USA
| | | | | | | |
Collapse
|
31
|
Yokus BMA, Daniele MA. Integrated non-invasive biochemical and biophysical sensing systems for health and performance monitoring: A systems perspective. Biosens Bioelectron 2021; 184:113249. [PMID: 33895689 DOI: 10.1016/j.bios.2021.113249] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 04/09/2021] [Accepted: 04/12/2021] [Indexed: 12/21/2022]
Abstract
Advances in materials, bio-recognition elements, transducers, and microfabrication techniques, as well as progress in electronics, signal processing, and wireless communication have generated a new class of skin-interfaced wearable health monitoring systems for applications in personalized medicine and digital health. In comparison to conventional medical devices, these wearable systems are at the cusp of initiating a new era of longitudinal and noninvasive sensing for the prevention, detection, diagnosis, and treatment of diseases at the molecular level. Herein, we provide a review of recent developments in wearable biochemical and biophysical systems. We survey the sweat sampling and collection methods for biochemical systems, followed by an assessment of biochemical and biophysical sensors deployed in current wearable systems with an emphasis on their hardware specifications. Specifically, we address how sweat collection and sample handling platforms may be a rate limiting technology to realizing the clinical translation of wearable health monitoring systems; moreover, we highlight the importance of achieving both longitudinal sensing and assessment of intrapersonal variation in sweat-blood correlations to have the greatest clinical impact. Lastly, we assess a snapshot of integrated wireless wearable systems with multimodal sensing capabilities, and we conclude with our perspective on the state-of-the-art and the required developments to achieve the next-generation of integrated wearable health and performance monitoring systems.
Collapse
Affiliation(s)
- By Murat A Yokus
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC, 27695, USA
| | - Michael A Daniele
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC, 27695, USA; Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, 911 Oval Dr., Raleigh, NC, 27695, USA.
| |
Collapse
|
32
|
Jiang N, Davies S, Jiao Y, Blyth J, Butt H, Montelongo Y, Yetisen AK. Doubly Photopolymerized Holographic Sensors. ACS Sens 2021; 6:915-924. [PMID: 33557517 DOI: 10.1021/acssensors.0c02109] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Holographic sensors are two-dimensional (2D) photonic crystals that diffract narrow-band light in the visible spectrum to quantify analytes in aqueous solutions. Here, a holographic fabrication setup was developed to produce holographic sensors through a doubly polymerization system of a poly-2-hydroxyethyl methacrylate hydrogel film using a pulsed Nd:YAG laser (λ = 355 nm, 5 ns, 100 mJ). Wavelength shifts of holographic Bragg peak in response to alcohol species (0-100 vol %) were characterized. Diffraction spectra showed that the holographic sensors could be used for short-chain alcohols at concentrations up to 60 vol %. The reversibility of the sensor was demonstrated, exhibiting a response time of 7.5 min for signal saturation. After 30 cycles, the Bragg peak and color remained the same in both 20 and 60 vol %. The fabrication parameters were simulated in MATLAB using a 2D finite-difference time-domain algorithm to model the interference pattern and energy flux profile of laser beam recording in the hydrogel medium. This work demonstrates a particle-free holographic sensor that offers continuous, reversible, and rapid colorimetric readouts for the real-time quantification of alcohols.
Collapse
Affiliation(s)
- Nan Jiang
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, U.K
| | - Sam Davies
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, U.K
| | - Yimeng Jiao
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, U.K
| | - Jeff Blyth
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, U.K
| | - Haider Butt
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi 127788, UAE
| | - Yunuen Montelongo
- Centro de Investigaciones en Óptica, A.C., Colonia Lomas del campestre, PC, León 37150, Mexico
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, U.K
| | - Ali K. Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, U.K
| |
Collapse
|
33
|
Saldich EB, Wang C, Rosen IG, Bartroff J, Luczak SE. Effects of stomach content on the breath alcohol concentration-transdermal alcohol concentration relationship. Drug Alcohol Rev 2021; 40:1131-1142. [PMID: 33713037 DOI: 10.1111/dar.13267] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 12/17/2020] [Accepted: 01/28/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Wearable devices that obtain transdermal alcohol concentration (TAC) could become valuable research tools for monitoring alcohol consumption levels in naturalistic environments if the TAC they produce could be converted into quantitatively-meaningful estimates of breath alcohol concentration (eBrAC). Our team has developed mathematical models to produce eBrAC from TAC, but it is not yet clear how a variety of factors affect the accuracy of the models. Stomach content is one factor that is known to affect breath alcohol concentration (BrAC), but its effect on the BrAC-TAC relationship has not yet been studied. METHODS We examine the BrAC-TAC relationship by having two investigators participate in four laboratory drinking sessions with varied stomach content conditions: (i) no meal, (ii) half and (iii) full meal before drinking, and (iv) full meal after drinking. BrAC and TAC were obtained every 10 min over the BrAC curve. RESULTS Eating before drinking lowered BrAC and TAC levels, with greater variability in TAC across person-device pairings, but the BrAC-TAC relationship was not consistently altered by stomach content. The mathematical model calibration parameters, fit indices, and eBrAC curves and summary score outputs did not consistently vary based on stomach content, indicating that our models were able to produce eBrAC from TAC with similar accuracy despite variations in the shape and magnitude of the BrAC curves under different conditions. DISCUSSION AND CONCLUSIONS This study represents the first examination of how stomach content affects our ability to model estimates of BrAC from TAC and indicates it is not a major factor.
Collapse
Affiliation(s)
- Emily B Saldich
- Department of Psychology, University of Southern California, Los Angeles, USA
| | - Chunming Wang
- Department of Mathematics, University of Southern California, Los Angeles, USA
| | - I Gary Rosen
- Department of Mathematics, University of Southern California, Los Angeles, USA
| | - Jay Bartroff
- Department of Mathematics, University of Southern California, Los Angeles, USA
| | - Susan E Luczak
- Department of Psychology, University of Southern California, Los Angeles, USA
| |
Collapse
|
34
|
Yin S, Liu X, Kaji T, Nishina Y, Miyake T. Fiber-crafted biofuel cell bracelet for wearable electronics. Biosens Bioelectron 2021; 179:113107. [PMID: 33640657 DOI: 10.1016/j.bios.2021.113107] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 02/16/2021] [Accepted: 02/17/2021] [Indexed: 12/19/2022]
Abstract
Wearable devices that generate power using sweat have garnered much attention in the field of skin electronics. These devices require high performance with a small volume and low production rate of sweat by living organisms. Here we demonstrate a high-power biofuel cell bracelet based on the lactate in human sweat. The biofuel cell was developed by using a lactate oxidase/osmium-based mediator/carbon nanotube fiber for lactate oxidation and a bilirubin oxidase/carbon nanotube fiber for oxygen reduction; the fibers were woven into a hydrophilic supportive textile for sweat storage. The storage textile was sandwiched between a hydrophobic textile for sweat absorption from the skin and a hydrophilic textile for water evaporation to improve sweat collection. The performance of the layered cell was 74 μW at 0.39 V in 20 mM artificial sweat lactate, and its performance was maintained at over 80% for 12 h. Furthermore, we demonstrated a series-connection between anode/cathode fibers by tying them up to wrap the bracelet-type biofuel cell on the wrist. The booster six-cell bracelet generated power at 2.0 V that is sufficient for operating digital wrist watches.
Collapse
Affiliation(s)
- Sijie Yin
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan
| | - Xiaohan Liu
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan
| | - Tatsuya Kaji
- Graduate School of Natural Science and Technology, Okayama University, Tsushimanaka, Kita-ku, Okayama, 700-8530, Japan
| | - Yuta Nishina
- Graduate School of Natural Science and Technology, Okayama University, Tsushimanaka, Kita-ku, Okayama, 700-8530, Japan
| | - Takeo Miyake
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan; PRESTO, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama, 332-0012, Japan.
| |
Collapse
|
35
|
Ethanol Biofuel Cells: Hybrid Catalytic Cascades as a Tool for Biosensor Devices. BIOSENSORS-BASEL 2021; 11:bios11020041. [PMID: 33557146 PMCID: PMC7913944 DOI: 10.3390/bios11020041] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 01/30/2021] [Accepted: 02/01/2021] [Indexed: 12/02/2022]
Abstract
Biofuel cells use chemical reactions and biological catalysts (enzymes or microorganisms) to produce electrical energy, providing clean and renewable energy. Enzymatic biofuel cells (EBFCs) have promising characteristics and potential applications as an alternative energy source for low-power electronic devices. Over the last decade, researchers have focused on enhancing the electrocatalytic activity of biosystems and on increasing energy generation and electronic conductivity. Self-powered biosensors can use EBFCs while eliminating the need for an external power source. This review details improvements in EBFC and catalyst arrangements that will help to achieve complete substrate oxidation and to increase the number of collected electrons. It also describes how analytical techniques can be employed to follow the intermediates between the enzymes within the enzymatic cascade. We aim to demonstrate how a high-performance self-powered sensor design based on EBFCs developed for ethanol detection can be adapted and implemented in power devices for biosensing applications.
Collapse
|
36
|
Sharma A, Badea M, Tiwari S, Marty JL. Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring. Molecules 2021; 26:748. [PMID: 33535493 PMCID: PMC7867046 DOI: 10.3390/molecules26030748] [Citation(s) in RCA: 97] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 01/24/2021] [Accepted: 01/26/2021] [Indexed: 12/18/2022] Open
Abstract
With the increasing prevalence of growing population, aging and chronic diseases continuously rising healthcare costs, the healthcare system is undergoing a vital transformation from the traditional hospital-centered system to an individual-centered system. Since the 20th century, wearable sensors are becoming widespread in healthcare and biomedical monitoring systems, empowering continuous measurement of critical biomarkers for monitoring of the diseased condition and health, medical diagnostics and evaluation in biological fluids like saliva, blood, and sweat. Over the past few decades, the developments have been focused on electrochemical and optical biosensors, along with advances with the non-invasive monitoring of biomarkers, bacteria and hormones, etc. Wearable devices have evolved gradually with a mix of multiplexed biosensing, microfluidic sampling and transport systems integrated with flexible materials and body attachments for improved wearability and simplicity. These wearables hold promise and are capable of a higher understanding of the correlations between analyte concentrations within the blood or non-invasive biofluids and feedback to the patient, which is significantly important in timely diagnosis, treatment, and control of medical conditions. However, cohort validation studies and performance evaluation of wearable biosensors are needed to underpin their clinical acceptance. In the present review, we discuss the importance, features, types of wearables, challenges and applications of wearable devices for biological fluids for the prevention of diseased conditions and real-time monitoring of human health. Herein, we summarize the various wearable devices that are developed for healthcare monitoring and their future potential has been discussed in detail.
Collapse
Affiliation(s)
- Atul Sharma
- School of Chemistry, Monash University, Clayton, Melbourne, VIC 3800, Australia
- Department of Pharmaceutical Chemistry, SGT College of Pharmacy, SGT University, Budhera, Gurugram, Haryana 122505, India
| | - Mihaela Badea
- Fundamental, Prophylactic and Clinical Specialties Department, Faculty of Medicine, Transilvania University of Brasov, 500036 Brasov, Romania;
| | - Swapnil Tiwari
- School of Studies in Chemistry, Pt Ravishankar Shukla University, Raipur, CHATTISGARH 492010, India;
| | - Jean Louis Marty
- University of Perpignan via Domitia, 52 Avenue Paul Alduy, CEDEX 9, 66860 Perpignan, France
| |
Collapse
|
37
|
Min J, Sempionatto JR, Teymourian H, Wang J, Gao W. Wearable electrochemical biosensors in North America. Biosens Bioelectron 2021; 172:112750. [DOI: 10.1016/j.bios.2020.112750] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 10/18/2020] [Accepted: 10/19/2020] [Indexed: 02/08/2023]
|
38
|
Davis-Martin RE, Alessi SM, Boudreaux ED. Alcohol Use Disorder in the Age of Technology: A Review of Wearable Biosensors in Alcohol Use Disorder Treatment. Front Psychiatry 2021; 12:642813. [PMID: 33828497 PMCID: PMC8019775 DOI: 10.3389/fpsyt.2021.642813] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 02/12/2021] [Indexed: 02/05/2023] Open
Abstract
Biosensors enable observation and understanding of latent physiological occurrences otherwise unknown or invasively detected. Wearable biosensors monitoring physiological constructs across a wide variety of mental and physical health conditions have become an important trend in innovative research methodologies. Within substance use research, explorations of biosensor technology commonly focus on identifying physiological indicators of intoxication to increase understanding of addiction etiology and to inform treatment recommendations. In this review, we examine the state of research in this area as it pertains to treatment of alcohol use disorders specifically highlighting the gaps in our current knowledge with recommendations for future research. Annually, alcohol use disorders affect approximately 15 million individuals. A primary focus of existing wearable technology-based research among people with alcohol use disorders is identifying alcohol intoxication. A large benefit of wearable biosensors for this purpose is they provide continuous readings in a passive manner compared with the gold standard measure of blood alcohol content (BAC) traditionally measured intermittently by breathalyzer or blood draw. There are two primary means of measuring intoxication with biosensors: gait and sweat. Gait changes have been measured via smart sensors placed on the wrist, in the shoe, and mobile device sensors in smart phones. Sweat measured by transdermal biosensors detects the presence of alcohol in the blood stream correlating to BAC. Transdermal biosensors have been designed in tattoos/skin patches, shirts, and most commonly, devices worn on the ankle or wrist. Transdermal devices were initially developed to help monitor court-ordered sobriety among offenders with alcohol use disorder. These devices now prove most useful in continuously tracking consumption throughout clinical trials for behavioral treatment modalities. More recent research has started exploring the uses for physical activity trackers and physiological arousal sensors to guide behavioral interventions for relapse prevention. While research has begun to demonstrate wearable devices' utility in reducing alcohol consumption among individuals aiming to cutdown on their drinking, monitoring sustained abstinence in studies exploring contingency management for alcohol use disorders, and facilitating engagement in activity-based treatment interventions, their full potential to further aid in understanding of, and treatment for, alcohol use disorders has yet to be explored.
Collapse
Affiliation(s)
- Rachel E Davis-Martin
- Department of Emergency Medicine, University of Massachusetts Medical School, Worcester, MA, United States
| | - Sheila M Alessi
- Department of Medicine, Calhoun Cardiology Center, University of Connecticut School of Medicine, Farmington, CT, United States
| | - Edwin D Boudreaux
- Department of Emergency Medicine, University of Massachusetts Medical School, Worcester, MA, United States
| |
Collapse
|
39
|
Li Z, Wang P. Point-of-Care Drug of Abuse Testing in the Opioid Epidemic. Arch Pathol Lab Med 2020; 144:1325-1334. [PMID: 32579399 DOI: 10.5858/arpa.2020-0055-ra] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2020] [Indexed: 11/06/2022]
Abstract
CONTEXT.— The United States is experiencing an opioid overdose epidemic. Point-of-care (POC) drug of abuse testing is a useful tool to combat the intensified opioid epidemic. OBJECTIVES.— To review commercially available POC drug of abuse testing involving opioids, to review opportunities and challenges for POC opioid testing and emerging testing methods in research literature, and finally to summarize unmet clinical needs and future development prospects. DATA SOURCES.— The Google search engine was used to access information for commercial opioid POC devices and the Google Scholar search engine was used to access research literature published from 2000 to 2019 for opioid POC tests. CONCLUSIONS.— The opioid epidemic provides unprecedented opportunities for POC drug testing, with significant clinical needs. Compared with gold standard tests, limitations for commercially available opioid POC testing include lower analytical sensitivity, lower specificity, and cross-reactivity. In response to unmet clinical needs, novel methods have emerged in research literature, such as microfluidics and miniature mass spectrometry. Future prospects include the development of quantitative POC devices and smarter and real-time drug testing.
Collapse
Affiliation(s)
- Zhao Li
- From the Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia
| | - Ping Wang
- From the Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia
| |
Collapse
|
40
|
Nemčeková K, Labuda J. Advanced materials-integrated electrochemical sensors as promising medical diagnostics tools: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 120:111751. [PMID: 33545892 DOI: 10.1016/j.msec.2020.111751] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/13/2020] [Accepted: 11/21/2020] [Indexed: 02/08/2023]
Abstract
Electrochemical sensors have increasingly been linked with terms as modern biomedically effective highly selective and sensitive devices, wearable and wireless technology, portable electronics, smart textiles, energy storage, communication and user-friendly operating systems. The work brings the overview of the current advanced materials and their application strategies for improving performance, miniaturization and portability of sensing devices. It provides the extensive information on recently developed (bio)sensing platforms based on voltammetric, amperometric, potentiometric and impedimetric detection modes including portable, non-invasive, wireless, and self-driven miniaturized devices for monitoring human and animal health. Diagnostics of selected free radical precursors, low molecular biomarkers, nucleic acids and protein-based biomarkers, bacteria and viruses of today's interest is demonstrated.
Collapse
Affiliation(s)
- Katarína Nemčeková
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava 81237, Slovakia.
| | - Ján Labuda
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava 81237, Slovakia.
| |
Collapse
|
41
|
Falk M, Psotta C, Cirovic S, Shleev S. Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6352. [PMID: 33171750 PMCID: PMC7664326 DOI: 10.3390/s20216352] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 11/03/2020] [Accepted: 11/04/2020] [Indexed: 12/14/2022]
Abstract
Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers and providers. This work overviews the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz. tears, sweat, saliva, and urine. Described electrochemical devices are based on different electrochemical techniques, viz. amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy. Challenges that confront researchers in this exciting area and key requirements for biodevices are discussed. It is concluded that the field of non-invasive sensing of biomarkers in bodily fluid is highly convoluted. Nonetheless, if the drawbacks are appropriately addressed, and the pitfalls are adroitly circumvented, the approach will most certainly disrupt current clinical and self-monitoring practices.
Collapse
Affiliation(s)
- Magnus Falk
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
| | - Carolin Psotta
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
- Aptusens AB, 293 94 Kyrkhult, Sweden
| | - Stefan Cirovic
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
| | - Sergey Shleev
- Department of Biomedical Science, Faculty of Health and Society, and Biofilms—Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden; (M.F.); (C.P.); (S.C.)
- Aptusens AB, 293 94 Kyrkhult, Sweden
| |
Collapse
|
42
|
Biscay J, Findlay E, Dennany L. Electrochemical monitoring of alcohol in sweat. Talanta 2020; 224:121815. [PMID: 33379040 DOI: 10.1016/j.talanta.2020.121815] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 10/19/2020] [Accepted: 10/23/2020] [Indexed: 10/23/2022]
Abstract
Rapid, periodic monitoring and detection of ethanol (EtOH) after consumption via a non-invasive measurement has been an area of increased research in recent years. Current point-of-care or on-site detection strategies rely on single use sensors which are inadequate for monitoring during a longer period. A low cost, portable and novel approach is developed here for real-time monitoring over several days utilising electrochemical techniques. The sensor shows oxidation of the ethanol in phosphate buffer and artificial sweat using the amperometric response from the application of +0.9 V to the polyaniline modified screen printed electrode using 1 mM EtOH as the averaged amount of EtOH eliminated in sweat after the consumption of one alcoholic beverage. Our enzyme based electrochemical sensor exhibits a qualitative assessment of the presence of EtOH in small volumes (≤40 μL) of 0.1 M sodium bicarbonate and subsequently artificial sweat, with 50 measurements taken daily over 11 days. While quantitative information is not obtained, the sensor system exhibits excellent stability after 3 months' dried storage in this complex biological matrix in an oxygen free cabinet. This addresses one of the key challenges for enzyme based electrochemical sensors, namely, the ability for real-time monitoring in complex biological matrices. The qualitative response illustrates the potential for this sensor to be exploited by non-experts which suggests the promise for their wider application in next-generation wearable electronics necessary for alcohol monitoring.
Collapse
Affiliation(s)
- Julien Biscay
- WestChem, Department of Pure and Applied Chemistry, University of Strathclyde, Technology and Innovation Centre, 99 George Street, Glasgow, G1 1RD, UK; Stirling University Innovation Park, Buddi Ltd, Unit 14, Scion House, Stirling, FK9 4NF, UK
| | - Ewan Findlay
- Stirling University Innovation Park, Buddi Ltd, Unit 14, Scion House, Stirling, FK9 4NF, UK
| | - Lynn Dennany
- WestChem, Department of Pure and Applied Chemistry, University of Strathclyde, Technology and Innovation Centre, 99 George Street, Glasgow, G1 1RD, UK.
| |
Collapse
|
43
|
Chen H, Simoska O, Lim K, Grattieri M, Yuan M, Dong F, Lee YS, Beaver K, Weliwatte S, Gaffney EM, Minteer SD. Fundamentals, Applications, and Future Directions of Bioelectrocatalysis. Chem Rev 2020; 120:12903-12993. [DOI: 10.1021/acs.chemrev.0c00472] [Citation(s) in RCA: 118] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Hui Chen
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Olja Simoska
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Koun Lim
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Matteo Grattieri
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Mengwei Yuan
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Fangyuan Dong
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Yoo Seok Lee
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Kevin Beaver
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Samali Weliwatte
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Erin M. Gaffney
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| | - Shelley D. Minteer
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, Utah 84112, United States
| |
Collapse
|
44
|
Teymourian H, Barfidokht A, Wang J. Electrochemical glucose sensors in diabetes management: an updated review (2010-2020). Chem Soc Rev 2020; 49:7671-7709. [PMID: 33020790 DOI: 10.1039/d0cs00304b] [Citation(s) in RCA: 349] [Impact Index Per Article: 69.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
While over half a century has passed since the introduction of enzyme glucose biosensors by Clark and Lyons, this important field has continued to be the focus of immense research activity. Extensive efforts during the past decade have led to major scientific and technological innovations towards tight monitoring of diabetes. Such continued progress toward advanced continuous glucose monitoring platforms, either minimal- or non-invasive, holds considerable promise for addressing the limitations of finger-prick blood testing toward tracking glucose trends over time, optimal therapeutic interventions, and improving the life of diabetes patients. However, despite these major developments, the field of glucose biosensors is still facing major challenges. The scope of this review is to present the key scientific and technological advances in electrochemical glucose biosensing over the past decade (2010-present), along with current obstacles and prospects towards the ultimate goal of highly stable and reliable real-time minimally-invasive or non-invasive glucose monitoring. After an introduction to electrochemical glucose biosensors, we highlight recent progress based on using advanced nanomaterials at the electrode-enzyme interface of three generations of glucose sensors. Subsequently, we cover recent activity and challenges towards next-generation wearable non-invasive glucose monitoring devices based on innovative sensing principles, alternative body fluids, advanced flexible materials, and novel platforms. This is followed by highlighting the latest progress in the field of minimally-invasive continuous glucose monitoring (CGM) which offers real-time information about interstitial glucose levels, by focusing on the challenges toward developing biocompatible membrane coatings to protect electrochemical glucose sensors against surface biofouling. Subsequent sections cover new analytical concepts of self-powered glucose sensors, paper-based glucose sensing and multiplexed detection of diabetes-related biomarkers. Finally, we will cover the latest advances in commercially available devices along with the upcoming future technologies.
Collapse
Affiliation(s)
- Hazhir Teymourian
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA.
| | | | | |
Collapse
|
45
|
Egmond K, Wright CJC, Livingston M, Kuntsche E. Wearable Transdermal Alcohol Monitors: A Systematic Review of Detection Validity, and Relationship Between Transdermal and Breath Alcohol Concentration and Influencing Factors. Alcohol Clin Exp Res 2020; 44:1918-1932. [DOI: 10.1111/acer.14432] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Accepted: 07/24/2020] [Indexed: 02/01/2023]
Affiliation(s)
- Kelly Egmond
- From the Centre for Alcohol Policy and Research (CAPR) (KE, CJCW, ML, EK) La Trobe University Melbourne Vic. Australia
| | - Cassandra J. C. Wright
- From the Centre for Alcohol Policy and Research (CAPR) (KE, CJCW, ML, EK) La Trobe University Melbourne Vic. Australia
- Burnet Institute(CJCW) Melbourne Vic. Australia
- School of Public Health and Preventive Medicine (CJCW) Monash University Melbourne Vic. Australia
| | - Michael Livingston
- From the Centre for Alcohol Policy and Research (CAPR) (KE, CJCW, ML, EK) La Trobe University Melbourne Vic. Australia
- School of Clinical Neuroscience (ML) Karolinska Institute Stockholm Sweden
| | - Emmanuel Kuntsche
- From the Centre for Alcohol Policy and Research (CAPR) (KE, CJCW, ML, EK) La Trobe University Melbourne Vic. Australia
- Institute of Psychology (EK) Eötvös Loránd University Budapest Hungary
| |
Collapse
|
46
|
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Screen-Printed Electrodes: Promising Paper and Wearable Transducers for (Bio)Sensing. BIOSENSORS 2020; 10:E76. [PMID: 32660011 PMCID: PMC7400178 DOI: 10.3390/bios10070076] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 07/05/2020] [Accepted: 07/07/2020] [Indexed: 12/18/2022]
Abstract
Screen-printing technology has revolutionized many fields, including that of electrochemical biosensing. Due to their current relevance, this review, unlike other papers, discusses the relevant aspects of electrochemical biosensors manufactured using this technology in connection to both paper substrates and wearable formats. The main trends, advances, and opportunities provided by these types of devices, with particular attention to the environmental and biomedical fields, are addressed along with illustrative fundamentals and applications of selected representative approaches from the recent literature. The main challenges and future directions to tackle in this research area are also pointed out.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (S.C.); (J.M.P.)
| | | | | |
Collapse
|
47
|
Sempionatto JR, Khorshed AA, Ahmed A, De Loyola e Silva AN, Barfidokht A, Yin L, Goud KY, Mohamed MA, Bailey E, May J, Aebischer C, Chatelle C, Wang J. Epidermal Enzymatic Biosensors for Sweat Vitamin C: Toward Personalized Nutrition. ACS Sens 2020; 5:1804-1813. [PMID: 32366089 DOI: 10.1021/acssensors.0c00604] [Citation(s) in RCA: 118] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Recent advances in wearable sensor technologies offer new opportunities for improving dietary adherence. However, despite their tremendous promise, the potential of wearable chemical sensors for guiding personalized nutrition solutions has not been reported. Herein, we present an epidermal biosensor aimed at following the dynamics of sweat vitamin C after the intake of vitamin C pills and fruit juices. Such skin-worn noninvasive electrochemical detection of sweat vitamin C has been realized by immobilizing the enzyme ascorbate oxidase (AAOx) on flexible printable tattoo electrodes and monitoring changes in the vitamin C level through changes in the reduction current of the oxygen cosubstrate. The flexible vitamin C tattoo patch was fabricated on a polyurethane substrate and combined with a localized iontophoretic sweat stimulation system along with amperometric cathodic detection of the oxygen depletion during the enzymatic reaction. The enzyme biosensor offers a highly selective response compared to the common direct (nonenzymatic) voltammetric measurements, with no effect on electroactive interfering species such as uric acid or acetaminophen. Temporal vitamin C profiles in sweat are demonstrated using different subjects taking varying amounts of commercial vitamin C pills or vitamin C-rich beverages. The dynamic rise and fall of such vitamin C sweat levels is thus demonstrated with no interference from other sweat constituents. Differences in such dynamics among the individual subjects indicate the potential of the epidermal biosensor for personalized nutrition solutions. The flexible tattoo patch displayed mechanical resiliency to multiple stretching and bending deformations. In addition, the AAOx biosensor is shown to be useful as a disposable strip for the rapid in vitro detection of vitamin C in untreated raw saliva and tears following pill or juice intake. These results demonstrate the potential of wearable chemical sensors for noninvasive nutrition status assessments and tracking of nutrient uptake toward detecting and correcting nutritional deficiencies, assessing adherence to vitamin intake, and supporting dietary behavior change.
Collapse
Affiliation(s)
- Juliane R. Sempionatto
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Ahmed A. Khorshed
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Aftab Ahmed
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Andre N. De Loyola e Silva
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Abbas Barfidokht
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Lu Yin
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - K. Yugender Goud
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Mona A. Mohamed
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| | - Eileen Bailey
- DSM Nutritional Products, Analytical Sciences, Wurmisweg 576, 4303 Kaiseraugst, Switzerland
| | - Jennifer May
- DSM Nutritional Products, Analytical Sciences, Wurmisweg 576, 4303 Kaiseraugst, Switzerland
| | - Claude Aebischer
- DSM Nutritional Products, Analytical Sciences, Wurmisweg 576, 4303 Kaiseraugst, Switzerland
| | - Claire Chatelle
- DSM Nutritional Products, Analytical Sciences, Wurmisweg 576, 4303 Kaiseraugst, Switzerland
| | - Joseph Wang
- Department of Nanoengineering, University of California, La Jolla, 92093 San Diego, California, United States
| |
Collapse
|
48
|
Mishra RK, Sempionatto JR, Li Z, Brown C, Galdino NM, Shah R, Liu S, Hubble LJ, Bagot K, Tapert S, Wang J. Simultaneous detection of salivary Δ 9-tetrahydrocannabinol and alcohol using a Wearable Electrochemical Ring Sensor. Talanta 2020; 211:120757. [PMID: 32070607 DOI: 10.1016/j.talanta.2020.120757] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/08/2020] [Accepted: 01/16/2020] [Indexed: 12/24/2022]
Abstract
Driving under the influence of cannabis and alcohol represents a major safety concern due to the synergistic or additive effect of these substances of abuse. Hence, rapid road-site testing of these substances is highly desired to reduce risks of fatal accidents. Here we describe a wearable electrochemical sensing device for the simultaneous direct, decentralized, detection of salivary THC and alcohol. The new ring-based sensing platform contains a voltammetric THC sensor and an amperometric alcohol biosensor on the ring cap, along with the wireless electronics embedded within the ring case. Rapid replacement of the disposable sensing-electrode ring cap following each saliva assay is accomplished by aligning spring-loaded pins, mounted on the electronic board (PCB), with the current collectors of the sensing electrodes. The printed dual-analyte sensor ring cover is based on a MWCNT/carbon electrode for the THC detection along with a Prussian-blue transducer, coated with alcohol oxidase/chitosan reagent layer, for the biosensing of alcohol. THC and alcohol can thus be detected simultaneously in the same diluted saliva sample within 3 min, with no cross talk and no interferences from the saliva matrix. The new wearable ring sensor platform should enable law enforcement personnel to screen drivers in a single traffic stop and offers considerable promise for addressing growing concerns of drug-impaired driving.
Collapse
Affiliation(s)
- Rupesh K Mishra
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA; Amity Institute of Biotechnology, Amity University Rajasthan, Jaipur, 303002, India
| | - Juliane R Sempionatto
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Zhanhong Li
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Christopher Brown
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Nathalia M Galdino
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Rushabh Shah
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Shuyang Liu
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Lee J Hubble
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA; CSIRO Manufacturing, Lindfield, New South Wales 2070, Australia
| | - Kara Bagot
- Department of Psychiatry, University of California, San Diego, La Jolla, CA 92093, USA; Department of Psychiatry, Addiction Institute of Mount Sinai, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Susan Tapert
- Department of Psychiatry, University of California, San Diego, La Jolla, CA 92093, USA
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego, La Jolla, CA 92093, USA.
| |
Collapse
|
49
|
El-Safty S, Shenashen M. Nanoscale dynamic chemical, biological sensor material designs for control monitoring and early detection of advanced diseases. Mater Today Bio 2020; 5:100044. [PMID: 32181446 PMCID: PMC7066237 DOI: 10.1016/j.mtbio.2020.100044] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 01/27/2020] [Accepted: 01/29/2020] [Indexed: 12/25/2022] Open
Abstract
Early detection and easy continuous monitoring of emerging or re-emerging infectious, contagious or other diseases are of particular interest for controlling healthcare advances and developing effective medical treatments to reduce the high global cost burden of diseases in the backdrop of lack of awareness regarding advancing diseases. Under an ever-increasing demand for biosensor design reliability for early stage recognition of infectious agents or contagious diseases and potential proteins, nanoscale manufacturing designs had developed effective nanodynamic sensing assays and compact wearable devices. Dynamic developments of biosensor technology are also vital to detect and monitor advanced diseases, such as human immunodeficiency virus (HIV), hepatitis B virus (HBV), hepatitis C virus (HCV), diabetes, cancers, liver diseases, cardiovascular diseases (CVDs), tuberculosis, and central nervous system (CNS) disorders. In particular, nanoscale biosensor designs have indispensable contribution to improvement of health concerns by early detection of disease, monitoring ecological and therapeutic agents, and maintaining high safety level in food and cosmetics. This review reports an overview of biosensor designs and their feasibility for early investigation, detection, and quantitative determination of many advanced diseases. Biosensor strategies are highlighted to demonstrate the influence of nanocompact and lightweight designs on accurate analyses and inexpensive sensing assays. To date, the effective and foremost developments in various nanodynamic designs associated with simple analytical facilities and procedures remain challenging. Given the wide evolution of biosensor market requirements and the growing demand in the creation of early stage and real-time monitoring assays, precise output signals, and easy-to-wear and self-regulating analyses of diseases, innovations in biosensor designs based on novel fabrication of nanostructured platforms with active surface functionalities would produce remarkable biosensor devices. This review offers evidence for researchers and inventors to focus on biosensor challenge and improve fabrication of nanobiosensors to revolutionize consumer and healthcare markets.
Collapse
Affiliation(s)
- S.A. El-Safty
- National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukubashi, Ibaraki-ken, 305-0047, Japan
| | | |
Collapse
|
50
|
Roberts W, McKee SA. Mobile alcohol biosensors and pharmacotherapy development research. Alcohol 2019; 81:149-160. [PMID: 31679765 DOI: 10.1016/j.alcohol.2018.07.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Revised: 07/27/2018] [Accepted: 07/30/2018] [Indexed: 01/12/2023]
Abstract
Recent advances in biosensor technology herald a major shift in the way alcohol use will be tracked in humans. Wearable biosensors can passively and continuously monitor wearers' alcohol consumption in real time. An important application of these biosensors is to improve the way medication for alcohol use disorder (AUD) is tested in clinical research. Both laboratory-based screening paradigms and clinical trials have methodological problems that impact their efficiency and predictive validity. Medication screening using laboratory-based methods is a resource-intensive assessment of a single episode of behavior in a non-representative setting. Clinical trials rely on participant self-report to document medication-induced changes in drinking behavior. This review describes how mobile biosensors can be leveraged to improve AUD medication development research. We first review the current state of alcohol biosensor technology with a focus on strengths and limitations of the devices. We describe how multiple biosensors can be combined to create a far more detailed record of drinking compared to single biosensor platforms. We then discuss each phase of the medication development pipeline in turn (i.e., phases 1-4) and describe how mobile biosensors can be incorporated in standard medication testing paradigms to improve efficiency and predictive validity. We conclude with discussion of challenges associated with using currently available biosensors for medication testing and recommendations for researchers wishing to incorporate alcohol biosensors into their own research.
Collapse
Affiliation(s)
- Walter Roberts
- Yale School of Medicine, Department of Psychiatry, New Haven, CT, United States.
| | - Sherry A McKee
- Yale School of Medicine, Department of Psychiatry, New Haven, CT, United States
| |
Collapse
|