1
|
Chitolina-Rodrigues G, Chandran D, R R, Silva-Neto HA. Recent advances in screen-printed carbon electrodes for food additive analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2025; 17:3613-3628. [PMID: 40270469 DOI: 10.1039/d5ay00236b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2025]
Abstract
Screen-printed carbon electrodes (SPCEs) are regarded as the actual and future sensing option for additive analysis in food samples; nonetheless, the sample preparation, selectivity, and detectability are key challenges to overcome for its technological development and wide application. In the present review, we inform, discuss, and compare some pivotal aspects associated with the fabrication of SPCEs, the presence of additives in foods, sample preparation, and voltammetric measurements of additives in food samples. Also, the proposed study has indicated that it is possible to develop suitable options for electroanalytical methodologies by using bare or modified SPCEs, which present affordable results in terms of selectivity, linear concentration range, and limit of detection for different classes of additives. Lastly, the review introduces challenging points that can be carefully evaluated for the next generation of SPCEs dedicated to additive analysis.
Collapse
Affiliation(s)
| | - Devu Chandran
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam, 690525, India.
| | - Rejithamol R
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam, 690525, India.
| | - Habdias A Silva-Neto
- Department of Chemistry, Federal University of Santa Catarina, Florianópolis, 88040-900, SC, Brazil.
| |
Collapse
|
2
|
Islam MR, Afroj S, Yin J, Novoselov KS, Chen J, Karim N. Advances in Printed Electronic Textiles. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2304140. [PMID: 38009793 PMCID: PMC10853734 DOI: 10.1002/advs.202304140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 09/11/2023] [Indexed: 11/29/2023]
Abstract
Electronic textiles (e-textiles) have emerged as a revolutionary solution for personalized healthcare, enabling the continuous collection and communication of diverse physiological parameters when seamlessly integrated with the human body. Among various methods employed to create wearable e-textiles, printing offers unparalleled flexibility and comfort, seamlessly integrating wearables into garments. This has spurred growing research interest in printed e-textiles, due to their vast design versatility, material options, fabrication techniques, and wide-ranging applications. Here, a comprehensive overview of the crucial considerations in fabricating printed e-textiles is provided, encompassing the selection of conductive materials and substrates, as well as the essential pre- and post-treatments involved. Furthermore, the diverse printing techniques and the specific requirements are discussed, highlighting the advantages and limitations of each method. Additionally, the multitude of wearable applications made possible by printed e-textiles is explored, such as their integration as various sensors, supercapacitors, and heated garments. Finally, a forward-looking perspective is provided, discussing future prospects and emerging trends in the realm of printed wearable e-textiles. As advancements in materials science, printing technologies, and design innovation continue to unfold, the transformative potential of printed e-textiles in healthcare and beyond is poised to revolutionize the way wearable technology interacts and benefits.
Collapse
Affiliation(s)
- Md Rashedul Islam
- Centre for Print Research (CFPR)University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| | - Shaila Afroj
- Centre for Print Research (CFPR)University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| | - Junyi Yin
- Department of BioengineeringUniversity of CaliforniaLos AngelesCA90095USA
| | - Kostya S. Novoselov
- Institute for Functional Intelligent MaterialsDepartment of Materials Science and EngineeringNational University of SingaporeSingapore117575Singapore
| | - Jun Chen
- Department of BioengineeringUniversity of CaliforniaLos AngelesCA90095USA
| | - Nazmul Karim
- Centre for Print Research (CFPR)University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
- Nottingham School of Art and DesignNottingham Trent UniversityShakespeare StreetNottinghamNG1 4GGUK
| |
Collapse
|
3
|
Mazzaracchio V, Rios Maciel M, Porto Santos T, Toda-Peters K, Shen AQ. Duplex Electrochemical Microfluidic Sensor for COVID-19 Antibody Detection: Natural versus Vaccine-Induced Humoral Response. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2207731. [PMID: 36916701 DOI: 10.1002/smll.202207731] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/03/2023] [Indexed: 06/18/2023]
Abstract
The rapid transmission and resilience of coronavirus disease 2019 (COVID-19) have led to urgent demands in monitoring humoral response for effective vaccine development, thus a multiplex co-detection platform to discriminate infection-induced from vaccine-induced antibodies is needed. Here a duplex electrochemical immunosensor for co-detection of anti-nucleocapsid IgG (N-IgG) and anti-spike IgG (S-IgG) is developed by using a two-working electrode system, via an indirect immunoassay, with antibody quantification obtained by differential pulse voltammetry. The screen-printed electrodes (SPEs) are modified by carbon black and electrodeposited gold nanoflowers for maximized surface areas, enabling the construction of an immunological chain for S-IgG and N-IgG electrochemical detection with enhanced performance. Using an optimized immunoassay protocol, a wide linear range between 30-750 and 20-1000 ng mL-1 , and a limit of detection of 28 and 15 ng mL-1 are achieved to detect N-IgG and S-IgG simultaneously in serum samples. This duplex immunosensor is then integrated in a microfluidic device to obtain significantly reduced detection time (≤ 7 min) while maintaining its analytical performance. The duplex microfluidic immunosensor can be easily expanded into multiplex format to achieve high throughput screening for the sero-surveillance of COVID-19 and other infectious diseases.
Collapse
Affiliation(s)
- Vincenzo Mazzaracchio
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa, 904-0495, Japan
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata,", Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Mauricio Rios Maciel
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa, 904-0495, Japan
| | - Tatiana Porto Santos
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa, 904-0495, Japan
| | - Kazumi Toda-Peters
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa, 904-0495, Japan
| | - Amy Q Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa, 904-0495, Japan
| |
Collapse
|
4
|
Büyüktaş D, Ghaani M, Rovera C, Carullo D, Olsson RT, Korel F, Farris S. A screen-printed electrode modified with gold nanoparticles/cellulose nanocrystals for electrochemical detection of 4,4′-methylene diphenyl diamine. Heliyon 2023; 9:e15327. [PMID: 37096008 PMCID: PMC10121457 DOI: 10.1016/j.heliyon.2023.e15327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 03/27/2023] [Accepted: 04/03/2023] [Indexed: 04/08/2023] Open
Abstract
Developing simple, cost-effective, easy-to-use, and reliable analytical devices if of utmost importance for the food industry for rapid in-line checks of their products that must comply with the provisions set by the current legislation. The purpose of this study was to develop a new electrochemical sensor for the food packaging sector. More specifically, we propose a screen-printed electrode (SPE) modified with cellulose nanocrystals (CNCs) and gold nanoparticles (AuNPs) for the quantification of 4,4'-methylene diphenyl diamine (MDA), which is one of the most important PAAs that can transfer from food packaging materials into food stuffs. The electrochemical performance of the proposed sensor (AuNPs/CNCs/SPE) in the presence of 4,4'-MDA was evaluated using cyclic voltammetry (CV). The modified AuNPs/CNCs/SPE showed the highest sensitivity for 4,4'-MDA detection, with a peak current of 9.81 μA compared with 7.08 μA for the bare SPE. The highest sensitivity for 4,4'-MDA oxidation was observed at pH = 7, whereas the detection limit was found at 57 nM and the current response of 4,4'-MDA rose linearly as its concentration increased from 0.12 μM to 100 μM. Experiments using real packaging materials revealed that employing nanoparticles dramatically improved both the sensitivity and the selectivity of the sensor, which can be thus considered as a new analytical tool for quick, simple, and accurate measurement of 4,4'-MDA during converting operations.
Collapse
Affiliation(s)
- Duygu Büyüktaş
- Department of Food Engineering, Faculty of Engineering, Izmir Institute of Technology, 35430, Gülbahçe Köyü, Urla, Izmir, Turkey
- DeFENS, Department of Food, Environmental and Nutritional Sciences, Food Packaging Lab., University of Milan, via Celoria 2 – I, 20133, Milan, Italy
| | - Masoud Ghaani
- DeFENS, Department of Food, Environmental and Nutritional Sciences, Food Packaging Lab., University of Milan, via Celoria 2 – I, 20133, Milan, Italy
| | - Cesare Rovera
- DeFENS, Department of Food, Environmental and Nutritional Sciences, Food Packaging Lab., University of Milan, via Celoria 2 – I, 20133, Milan, Italy
| | - Daniele Carullo
- DeFENS, Department of Food, Environmental and Nutritional Sciences, Food Packaging Lab., University of Milan, via Celoria 2 – I, 20133, Milan, Italy
| | - Richard T. Olsson
- Department of Fibre and Polymer Technology, School of Chemical Science and Engineering, KTH Royal Institute of Technology, Teknikringen 56, SE-100 44, Stockholm, Sweden
| | - Figen Korel
- Department of Food Engineering, Faculty of Engineering, Izmir Institute of Technology, 35430, Gülbahçe Köyü, Urla, Izmir, Turkey
| | - Stefano Farris
- DeFENS, Department of Food, Environmental and Nutritional Sciences, Food Packaging Lab., University of Milan, via Celoria 2 – I, 20133, Milan, Italy
- INSTM, National Consortium of Materials Science and Technology, Local Unit University of Milan, via Celoria 2 – I, 20133, Milan, Italy
- Corresponding author. DeFENS, Department of Food, Environmental and Nutritional Sciences, Food Packaging Lab., University of Milan, via Celoria 2 – I, 20133, Milan, Italy.
| |
Collapse
|
5
|
Falahi S, Falahi S, Zarejousheghani M, Ehrlich H, Joseph Y, Rahimi P. Electrochemical Sensing of Gallic Acid in Beverages Using a 3D Bio-Nanocomposite Based on Carbon Nanotubes/Spongin-Atacamite. BIOSENSORS 2023; 13:262. [PMID: 36832028 PMCID: PMC9954721 DOI: 10.3390/bios13020262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 02/09/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
Gallic acid (GA) is one of the most important polyphenols, being widely used in the food, cosmetic, and pharmaceutical industries due to its biological effects such as antioxidant, antibacterial, anticancer, antiviral, anti-inflammatory, and cardioprotective properties. Hence, simple, fast, and sensitive determination of GA is of particular importance. Considering the fact that GA is an electroactive compound, electrochemical sensors offer great potential for GA quantitation due to their fast response time, high sensitivity, and ease of use. A simple, fast, and sensitive GA sensor was fabricated on the basis of a high-performance bio-nanocomposite using spongin as a natural 3D polymer, atacamite, and multi-walled carbon nanotubes (MWCNTs). The developed sensor showed an excellent response toward GA oxidation with remarkable electrochemical features due to the synergistic effects of 3D porous spongin and MWCNTs, which provide a large surface area and enhance the electrocatalytic activity of atacamite. At optimal conditions by differential pulse voltammetry (DPV), a good linear relationship was obtained between peak currents and GA concentrations in a wild linear range of 500 nM to 1 mM. Subsequently, the proposed sensor was used to detect GA in red wine as well as in green and black tea, confirming its great potential as a reliable alternative to conventional methods for GA determination.
Collapse
Affiliation(s)
- Sedigheh Falahi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Sepideh Falahi
- Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah 6715847141, Iran
| | - Mashaalah Zarejousheghani
- Freiberg Center for Water Research-ZeWaF, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Hermann Ehrlich
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Yvonne Joseph
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
- Freiberg Center for Water Research-ZeWaF, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Parvaneh Rahimi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
- Freiberg Center for Water Research-ZeWaF, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| |
Collapse
|
6
|
Pigani L, Rioli C, Zanfrognini B, García-Guzmán JJ, Palacios-Santander JM, Cubillana-Aguilera LM. Fast Analysis of Caffeic Acid-Related Molecules in Instant Coffee by Reusable Sonogel-Carbon Electrodes. SENSORS (BASEL, SWITZERLAND) 2022; 22:8448. [PMID: 36366146 PMCID: PMC9655352 DOI: 10.3390/s22218448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/21/2022] [Accepted: 10/29/2022] [Indexed: 06/16/2023]
Abstract
Reusable Sonogel-Carbon electrodes containing carbon black (SNGC-CB) have been used for the electrochemical analysis of caffeic acid (CA) in real matrices. Measurements were firstly performed in standard solutions, in which SNGC-CB electrodes allowed the electrochemical determination of CA with high sensitivity and low limit of detection, equal to 0.76 μM. The presence of CB nanostructures in the formulation led to improved performances with respect to pristine SNGC electrodes. Then, measurements were performed in four instant coffees of different brands. A comparison between the results obtained by electrochemical, chromatographic and spectroscopic methods showed that SBGC-CB electrodes represent a simple and economic tool for the rapid assessment of caffeic acid-related molecules in instant coffees.
Collapse
Affiliation(s)
- Laura Pigani
- Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Modena e Reggio Emilia, Via G. Campi, 103, 41125 Modena, Italy
| | - Cristina Rioli
- Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Modena e Reggio Emilia, Via G. Campi, 103, 41125 Modena, Italy
| | - Barbara Zanfrognini
- Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Modena e Reggio Emilia, Via G. Campi, 103, 41125 Modena, Italy
| | - Juan José García-Guzmán
- Instituto de Investigación e Innovación Biomédica de Cadiz (INiBICA), Hospital Universitario ‘Puerta del Mar’, Universidad de Cadiz, 11009 Cadiz, Spain
| | - José Maria Palacios-Santander
- Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar, University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510 Puerto Real, Cadiz, Spain
| | - Laura María Cubillana-Aguilera
- Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar, University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510 Puerto Real, Cadiz, Spain
| |
Collapse
|
7
|
Islam MR, Afroj S, Novoselov KS, Karim N. Smart Electronic Textile-Based Wearable Supercapacitors. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2203856. [PMID: 36192164 PMCID: PMC9631069 DOI: 10.1002/advs.202203856] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 09/05/2022] [Indexed: 05/05/2023]
Abstract
Electronic textiles (e-textiles) have drawn significant attention from the scientific and engineering community as lightweight and comfortable next-generation wearable devices due to their ability to interface with the human body, and continuously monitor, collect, and communicate various physiological parameters. However, one of the major challenges for the commercialization and further growth of e-textiles is the lack of compatible power supply units. Thin and flexible supercapacitors (SCs), among various energy storage systems, are gaining consideration due to their salient features including excellent lifetime, lightweight, and high-power density. Textile-based SCs are thus an exciting energy storage solution to power smart gadgets integrated into clothing. Here, materials, fabrications, and characterization strategies for textile-based SCs are reviewed. The recent progress of textile-based SCs is then summarized in terms of their electrochemical performances, followed by the discussion on key parameters for their wearable electronics applications, including washability, flexibility, and scalability. Finally, the perspectives on their research and technological prospects to facilitate an essential step towards moving from laboratory-based flexible and wearable SCs to industrial-scale mass production are presented.
Collapse
Affiliation(s)
- Md Rashedul Islam
- Centre for Print Research (CFPR)The University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| | - Shaila Afroj
- Centre for Print Research (CFPR)The University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| | - Kostya S. Novoselov
- Institute for Functional Intelligent Materials, Department of Materials Science and EngineeringNational University of SingaporeSingapore117575Singapore
- Chongqing 2D Materials InstituteLiangjiang New AreaChongqing400714China
| | - Nazmul Karim
- Centre for Print Research (CFPR)The University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| |
Collapse
|
8
|
Screen-printed electrode modified by Au/NH2-MIL-125(Ti) composite for electrochemical sensing performance of gallic acid in green tea and urine samples. Chem Phys Lett 2022. [DOI: 10.1016/j.cplett.2022.140074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
9
|
Bounegru AV, Apetrei C. Studies on the Detection of Oleuropein from Extra Virgin Olive Oils Using Enzymatic Biosensors. Int J Mol Sci 2022; 23:ijms232012569. [PMID: 36293426 PMCID: PMC9604468 DOI: 10.3390/ijms232012569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/10/2022] [Accepted: 10/17/2022] [Indexed: 12/05/2022] Open
Abstract
Oleuropein (OLEU) is an important indicator of the quality and authenticity of extra virgin olive oils (EVOO). Electrochemical sensors and biosensors for the detection of oleuropein can be used to test the adulteration of extra virgin olive oils. The present study aimed at the qualitative and quantitative determination of oleuropein in commercial EVOO samples by applying electrochemical techniques, cyclic voltammetry (CV) and square wave voltammetry (SWV). The sensing devices used were two newly constructed enzyme biosensors, supported on single-layer carbon-nanotube-modified carbon screen-printed electrode (SPE/SWCNT) on whose surface tyrosinase (SPE/SWCNT/Tyr) and laccase (SPE/SWCNT/Lac) were immobilized, respectively. The active surfaces of the two biosensors were analyzed and characterized by different methods, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared spectroscopy (FTIR) and the results confirmed the efficient immobilization of the enzymes. SPE/SWCNT/Tyr was characterized by a low detection limit (LOD = 9.53 × 10−8 M) and a very good sensitivity (0.0718 μA·μM−1·cm−2) over a wide linearity range from 0.49 to 11.22 μM. The process occurring at the biosensor surface corresponds to kinetics (h = 0.90), and tyrosinase showed a high affinity towards OLEU. The tyrosinase-based biosensor was shown to have superior sensitive properties to the laccase-based one. Quantitative determination of OLEU in EVOOs was performed using SPE/SWCNT/Tyr and the results confirmed the presence of the compound in close amounts in the EVOOs analysed, proving that they have very good sensory properties.
Collapse
|
10
|
Silveri F, Della Pelle F, Scroccarello A, Mazzotta E, Di Giulio T, Malitesta C, Compagnone D. Carbon Black Functionalized with Naturally Occurring Compounds in Water Phase for Electrochemical Sensing of Antioxidant Compounds. Antioxidants (Basel) 2022; 11:antiox11102008. [PMID: 36290731 PMCID: PMC9598705 DOI: 10.3390/antiox11102008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 10/04/2022] [Accepted: 10/04/2022] [Indexed: 11/18/2022] Open
Abstract
A new sustainable route to nanodispersed and functionalized carbon black in water phase (W-CB) is proposed. The sonochemical strategy exploits ultrasounds to disaggregate the CB, while two selected functional naturally derived compounds, sodium cholate (SC) and rosmarinic acid (RA), act as stabilizing agents ensuring dispersibility in water adhering onto the CB nanoparticles’ surface. Strategically, the CB-RA compound is used to drive the AuNPs self-assembling at room temperature, resulting in a CB surface that is nanodecorated; further, this is achieved without the need for additional reagents. Electrochemical sensors based on the proposed nanomaterials are realized and characterized both morphologically and electrochemically. The W-CBs’ electroanalytical potential is proved in the anodic and cathodic window using caffeic acid (CF) and hydroquinone (HQ), two antioxidant compounds that are significant for food and the environment. For both antioxidants, repeatable (RSD ≤ 3.3%; n = 10) and reproducible (RSD ≤ 3.8%; n = 3) electroanalysis results were obtained, achieving nanomolar detection limits (CF: 29 nM; HQ: 44 nM). CF and HQ are successfully determined in food and environmental samples (recoveries 97–113%), and also in the presence of other phenolic classes and HQ structural isomers. The water dispersibility of the proposed materials can be an opportunity for (bio) sensor fabrication and sustainable device realization.
Collapse
Affiliation(s)
- Filippo Silveri
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
| | - Flavio Della Pelle
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
- Correspondence: (F.D.P.); (D.C.); Tel.: +39-0861-266948 (F.D.P.); +39-0861-266942 (D.C.)
| | - Annalisa Scroccarello
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
| | - Elisabetta Mazzotta
- Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Universitaà del Salento, Via Monteroni, 73100 Lecce, Italy
| | - Tiziano Di Giulio
- Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Universitaà del Salento, Via Monteroni, 73100 Lecce, Italy
| | - Cosimino Malitesta
- Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Universitaà del Salento, Via Monteroni, 73100 Lecce, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
- Correspondence: (F.D.P.); (D.C.); Tel.: +39-0861-266948 (F.D.P.); +39-0861-266942 (D.C.)
| |
Collapse
|
11
|
Manoj D, Rajendran S, Hoang TKA, Soto-Moscoso M. The role of MOF based nanocomposites in the detection of phenolic compounds for environmental remediation- A review. CHEMOSPHERE 2022; 300:134516. [PMID: 35398074 DOI: 10.1016/j.chemosphere.2022.134516] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/02/2022] [Accepted: 04/01/2022] [Indexed: 06/14/2023]
Abstract
Phenolic compounds would be the emerging pollutant by 2050, because of their wide spread applicability in daily life and therefore the adoption of suitable detection methods in which identification and separation of isomers is highly desirable. Owing to the fascinating features, Metal-organic framework (MOF), a class of reticular materials holds a large surface area with tunable shape and adjustable porosity will provide strong interaction with analytes through abundant functional groups resulting in high selectivity towards electrochemical determination of phenolic isomers. Nevertheless, the sensing performance can still be further improved by building MOF network (intrinsic resistance) with functional (conducting) materials, resulting in MOF based nanocomposite. Herein, this review provides the summary of MOF based nanocomposites for electrochemical sensing of phenolic compounds developed from 2015. In this review, we discussed the demerits of pristine MOF as electrode materials, and the requirement of new class of MOF with functional materials such as nanomaterials, carbon nanotubes, graphene and MXene. The history and evolution of MOF nanocomposite-based materials are discussed and also featured the impressive physical and chemical properties. Besides this review discusses the factors influencing the conducting pathway and mass transport of MOF based nanocomposite for enhanced sensing performance of phenolic compounds with suitable mechanistic illustrations. Finally, the major challenges governing the determination of phenolic compounds and the future advancements required for the development of MOF based electrodes for various applications are highlighted.
Collapse
Affiliation(s)
- Devaraj Manoj
- Departamento de Ingeniería Mecánica, Facultad de Ingeniería, Universidad de Tarapacá, Avda. General Velásquez 1775, Arica, Chile.
| | - Saravanan Rajendran
- Departamento de Ingeniería Mecánica, Facultad de Ingeniería, Universidad de Tarapacá, Avda. General Velásquez 1775, Arica, Chile.
| | - Tuan K A Hoang
- Centre of Excellence in Transportation Electrification and Energy Storage, Hydro-Québec, 1806, boul. Lionel-Boulet, Varennes, J3X 1S1, Canada
| | | |
Collapse
|
12
|
Neven L, Barich H, Rutten R, De Wael K. Novel (Photo)electrochemical Analysis of Aqueous Industrial Samples Containing Phenols. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
13
|
Carbon-black combined with TiO2 and KuQ as sustainable photosystem for a reliable self-powered photoelectrochemical biosensor. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
14
|
Neven L, Barich H, Sleegers N, Cánovas R, Debruyne G, De Wael K. Development of a combi-electrosensor for the detection of phenol by combining photoelectrochemistry and square wave voltammetry. Anal Chim Acta 2022; 1206:339732. [DOI: 10.1016/j.aca.2022.339732] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 03/08/2022] [Accepted: 03/14/2022] [Indexed: 11/27/2022]
|
15
|
Electrochemical sensors based on sewage sludge-derived biochar for the analysis of anthocyanins in berry fruits. Anal Bioanal Chem 2022; 414:6295-6307. [PMID: 35471251 PMCID: PMC9372006 DOI: 10.1007/s00216-022-04062-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 03/28/2022] [Accepted: 04/04/2022] [Indexed: 01/27/2023]
Abstract
The reutilization of waste and the reduction of the general environmental impact of every production are fundamental goals that must be achieved in the framework of a circular economy. Recycled carbon-rich materials may represent a promising alternative to other less-sustainable carbonaceous materials used in the production of electrochemical sensing platforms. Herein, we propose an innovative carbon paste electrode (CPE) composed of biochar derived from biological sludge obtained from municipal and industrial wastewater treatment plants. The physicochemical properties of the biochar after a chemical treatment with an acidic solution obtained from industrial by-products were investigated. The electrode surface characterization was carried out by analyzing common redox probes and multiple phenols bearing varying numbers of –OH and –OCH3 groups in their structure. Furthermore, the CPE was also tested on the evaluation of the phenolic fingerprints of Vaccinium myrtillus, Vaccinium uliginosum subsp. gaultherioides, and Fragaria × ananassa. Standard anthocyanin mixtures and extracts of the aforementioned fruits were analyzed to provide a phenolic characterization of real samples. The obtained results show that the sewage sludge–derived biochar can be a promising material for the development of electroanalytical sensors.
Collapse
|
16
|
Functionalization of Screen-Printed Sensors with a High Reactivity Carbonaceous Material for Ascorbic Acid Detection in Fresh-Cut Fruit with Low Vitamin C Content. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9120354] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, carbon screen-printed sensors (C-SPEs) were functionalized with a high reactivity carbonaceous material (HRCM) to measure the ascorbic acid (AA) concentration in fresh-cut fruit (i.e., watermelon and apple) with a low content of vitamin C. HRCM and the functionalized working electrodes (WEs) were characterized by SEM and TEM. The increases in the electroactive area and in the diffusion of AA molecules towards the WE surface were evaluated by cyclic voltammetry (CV) and chronoamperometry. The performance of HRCM-SPEs were evaluated by CV and constant potential amperometry compared with the non-functionalized C-SPEs and MW-SPEs nanostructured with multi-walled carbon nanotubes. The results indicated that SPEs functionalized with 5 mg/mL of HRCM and 10 mg/mL of MWCNTs had the best performances. HRCM and MWCNTs increased the electroactive area by 1.2 and 1.4 times, respectively, whereas, after functionalization, the AA diffusion rate towards the electrode surface increased by an order of 10. The calibration slopes of HRCM and MWCNTs improved from 1.9 to 3.7 times, thus reducing the LOD of C-SPE from 0.55 to 0.15 and 0.28 μM, respectively. Finally, the functionalization of the SPEs proved to be indispensable for determining the AA concentration in the watermelon and apple samples.
Collapse
|
17
|
Jemmeli D, Dridi C, Abbas MN, Dempsey E. Development of highly sensitive and selective bisphenol A sensor based on a cobalt phthalocyanine-modified carbon paste electrode: application in dairy analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4674-4682. [PMID: 34549730 DOI: 10.1039/d1ay00827g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The development of an accurate, sensitive and selective sensor for the detection of bisphenol A (BPA) based on the incorporation of a new phthalocyanine derivative, cobalt phthalocyanine, C,C,C,C-tetracarboxylic acid-polyacrylamide (CoPc-PAA) into a carbon-paste matrix is presented using voltammetry and constant potential techniques. The influence of measuring parameters such as pH and scan rate on the analytical performance of the sensor was evaluated. Several kinetic parameters such as electron transfer number (n), charge transfer coefficient (α), electrode surface area (A) and diffusion coefficient (D) were also calculated. Under optimum conditions, particularly at pH 7.2, the BPA sensor resulted in a wide linear range from 25 × 10-11 M to 2.5 × 10-7 M and a limit of detection as low as 63.5 pM. Based on these findings, it can be concluded that our sensor can be substantially utilized for detecting BPA in spiked milk samples.
Collapse
Affiliation(s)
- Dhouha Jemmeli
- NANOMISENE Laboratory LR16CRMN01, Center of Research on Microelectronics and Nanotechnology (CRMN), Sousse Technopole, Tunisia.
| | - Chérif Dridi
- NANOMISENE Laboratory LR16CRMN01, Center of Research on Microelectronics and Nanotechnology (CRMN), Sousse Technopole, Tunisia.
| | - Mohammed N Abbas
- Analytical Laboratory, Department of Applied Organic Chemistry Polymer and Pigments Department, National Research Centre, Cairo, Egypt
| | - Eithne Dempsey
- Kathleen Lonsdale Institute for Human Health Research, Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland
| |
Collapse
|
18
|
Sensing Methods for Hazardous Phenolic Compounds Based on Graphene and Conducting Polymers-Based Materials. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9100291] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
It has been known for years that the phenolic compounds are able to exert harmful effects toward living organisms including humans due to their high toxicity. Living organisms were exposed to these phenolic compounds as they were released into the environment as waste products from several fast-growing industries. In this regard, tremendous efforts have been made by researchers to develop sensing methods for the detection of these phenolic compounds. Graphene and conducting polymers-based materials have arisen as a high potential sensing layer to improve the performance of the developed sensors. Henceforth, this paper reviews the existing investigations on graphene and conducting polymer-based materials incorporated with various sensors that aimed to detect hazardous phenolic compounds, i.e., phenol, 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol, 2-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol, and 2,4-dimethylphenol. The whole picture and up-to-date information on the graphene and conducting polymers-based sensors are arranged in systematic chronological order to provide a clearer insight in this research area. The future perspectives of this study are also included, and the development of sensing methods for hazardous phenolic compounds using graphene and conducting polymers-based materials is expected to grow more in the future.
Collapse
|
19
|
Mazzaracchio V, Serani A, Fiore L, Moscone D, Arduini F. All-solid state ion-selective carbon black-modified printed electrode for sodium detection in sweat. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.139050] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
20
|
Yi Z, Kun-Lin Y. Quantitative detection of phenol in wastewater using square wave voltammetry with pre-concentration. Anal Chim Acta 2021; 1178:338788. [PMID: 34482861 DOI: 10.1016/j.aca.2021.338788] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 06/12/2021] [Accepted: 06/20/2021] [Indexed: 10/21/2022]
Abstract
Phenol is a common pollutant found in wastewater, and its allowable discharge limit is 0.5 parts-per-million (ppm). Therefore, it is critical to monitor phenol in the sub-ppm range with high sensitivity and a low limit of detection. Herein, we report a quantitative method for detecting phenol in industrial wastewater through square wave voltammetry (SWV), in which phenol is oxidized to phenoxyl radicals and then became catechol and hydroquinone for detection. By using this method, phenol in the sub-ppm range can be detected reliably over a wide pH range. The sensitivity can be further improved by using a pre-concentration step for phenol before scanning. The method has a limit of detection of 0.1 ppb for phenol. Finally, three graphite electrodes were applied as working, counter and reference electrodes, respectively, in a millifluidic device for continuous detection of phenol in industrial wastewater flowing at 300 μL/min. Because of its simplicity, the sensor can be mass-produced and deployed on a large scale to monitor phenol in industrial wastewater.
Collapse
Affiliation(s)
- Zhang Yi
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117576, Singapore
| | - Yang Kun-Lin
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117576, Singapore.
| |
Collapse
|
21
|
Hussain A, Rafeeq H, Qasim M, Jabeen Z, Bilal M, Franco M, Iqbal HMN. Engineered tyrosinases with broadened bio-catalysis scope: immobilization using nanocarriers and applications. 3 Biotech 2021; 11:365. [PMID: 34290948 PMCID: PMC8257883 DOI: 10.1007/s13205-021-02913-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 06/28/2021] [Indexed: 02/08/2023] Open
Abstract
Enzyme immobilization is a widely used technology for creating more stable, active, and reusable biocatalysts. The immobilization process also improves the enzyme's operating efficiency in industrial applications. Various support matrices have been designed and developed to enhance the biocatalytic efficiency of immobilized enzymes. Given their unique physicochemical attributes, including substantial surface area, rigidity, semi-conductivity, high enzyme loading, hyper catalytic activity, and size-assisted optical properties, nanomaterials have emerged as fascinating matrices for enzyme immobilization. Tyrosinase is a copper-containing monooxygenase that catalyzes the o-hydroxylation of monophenols to catechols and o-quinones. This enzyme possesses a wide range of uses in the medical, biotechnological, and food sectors. This article summarizes an array of nanostructured materials as carrier matrices for tyrosinase immobilization. Following a detailed background overview, various nanomaterials, as immobilization support matrices, including carbon nanotubes (CNTs), carbon dots (CDs), carbon black (CB), nanofibers, Graphene nanocomposite, platinum nanoparticles, nano-sized magnetic particles, lignin nanoparticles, layered double hydroxide (LDH) nanomaterials, gold nanoparticles (AuNPs), and zinc oxide nanoparticles have been discussed. Next, applied perspectives have been spotlights with particular reference to environmental pollutant sensing, phenolic compounds detection, pharmaceutical, and food industry (e.g., cereal processing, dairy processing, and meat processing), along with other miscellaneous applications.
Collapse
Affiliation(s)
- Asim Hussain
- Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Hamza Rafeeq
- Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Muhammad Qasim
- International Islamic University Islamabad, Islamabad, Pakistan
| | - Zara Jabeen
- Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huai’an, 223003 China
| | - Marcelo Franco
- Departament of Exact Sciences and Technology, State University of Santa Cruz, Ilhéus, Brazil
| | - Hafiz M. N. Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, 64849 Monterrey, Mexico
| |
Collapse
|
22
|
Kanoun O, Lazarević-Pašti T, Pašti I, Nasraoui S, Talbi M, Brahem A, Adiraju A, Sheremet E, Rodriguez RD, Ben Ali M, Al-Hamry A. A Review of Nanocomposite-Modified Electrochemical Sensors for Water Quality Monitoring. SENSORS (BASEL, SWITZERLAND) 2021; 21:4131. [PMID: 34208587 PMCID: PMC8233775 DOI: 10.3390/s21124131] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 12/12/2022]
Abstract
Electrochemical sensors play a significant role in detecting chemical ions, molecules, and pathogens in water and other applications. These sensors are sensitive, portable, fast, inexpensive, and suitable for online and in-situ measurements compared to other methods. They can provide the detection for any compound that can undergo certain transformations within a potential window. It enables applications in multiple ion detection, mainly since these sensors are primarily non-specific. In this paper, we provide a survey of electrochemical sensors for the detection of water contaminants, i.e., pesticides, nitrate, nitrite, phosphorus, water hardeners, disinfectant, and other emergent contaminants (phenol, estrogen, gallic acid etc.). We focus on the influence of surface modification of the working electrodes by carbon nanomaterials, metallic nanostructures, imprinted polymers and evaluate the corresponding sensing performance. Especially for pesticides, which are challenging and need special care, we highlight biosensors, such as enzymatic sensors, immunobiosensor, aptasensors, and biomimetic sensors. We discuss the sensors' overall performance, especially concerning real-sample performance and the capability for actual field application.
Collapse
Affiliation(s)
- Olfa Kanoun
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
| | - Tamara Lazarević-Pašti
- Department of Physical Chemistry, “VINČA” Institute of Nuclear Sciences—National Institute of the Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia;
| | - Igor Pašti
- Faculty of Physical Chemistry, University of Belgrade, 11000 Belgrade, Serbia;
| | - Salem Nasraoui
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Malak Talbi
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Amina Brahem
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Anurag Adiraju
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
| | - Evgeniya Sheremet
- Research School of Physics, Tomsk Polytechnic University, Tomsk 634050, Russia;
| | - Raul D. Rodriguez
- Research School of Chemical and Biomedical Technologies, Tomsk Polytechnic University, Tomsk 634050, Russia;
| | - Mounir Ben Ali
- NANOMISENE Lab, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse B.P. 334, Sahloul, Sousse 4034, Tunisia;
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, 4003 Tunisia of Sousse, GREENS-ISSAT, Cité Ettafala, Ibn Khaldoun, Sousse 4003, Tunisia
| | - Ammar Al-Hamry
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111 Chemnitz, Germany; (S.N.); (M.T.); (A.B.); (A.A.); (A.A.-H.)
| |
Collapse
|
23
|
Sempionatto JR, Montiel VRV, Vargas E, Teymourian H, Wang J. Wearable and Mobile Sensors for Personalized Nutrition. ACS Sens 2021; 6:1745-1760. [PMID: 34008960 DOI: 10.1021/acssensors.1c00553] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
While wearable and mobile chemical sensors have experienced tremendous growth over the past decade, their potential for tracking and guiding nutrition has emerged only over the past three years. Currently, guidelines from doctors and dietitians represent the most common approach for maintaining optimal nutrition status. However, such recommendations rely on population averages and do not take into account individual variability in responding to nutrients. Precision nutrition has recently emerged to address the large heterogeneity in individuals' responses to diet, by tailoring nutrition based on the specific requirements of each person. It aims at preventing and managing diseases by formulating personalized dietary interventions to individuals on the basis of their metabolic profile, background, and environmental exposure. Recent advances in digital nutrition technology, including calories-counting mobile apps and wearable motion tracking devices, lack the ability of monitoring nutrition at the molecular level. The realization of effective precision nutrition requires synergy from different sensor modalities in order to make timely reliable predictions and efficient feedback. This work reviews key opportunities and challenges toward the successful realization of effective wearable and mobile nutrition monitoring platforms. Non-invasive wearable and mobile electrochemical sensors, capable of monitoring temporal chemical variations upon the intake of food and supplements, are excellent candidates to bridge the gap between digital and biochemical analyses for a successful personalized nutrition approach. By providing timely (previously unavailable) dietary information, such wearable and mobile sensors offer the guidance necessary for supporting dietary behavior change toward a managed nutritional balance. Coupling of the rapidly emerging wearable chemical sensing devices-generating enormous dynamic analytical data-with efficient data-fusion and data-mining methods that identify patterns and make predictions is expected to revolutionize dietary decision-making toward effective precision nutrition.
Collapse
Affiliation(s)
- Juliane R. Sempionatto
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | | | - Eva Vargas
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Hazhir Teymourian
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| |
Collapse
|
24
|
Antonacci A, Attaallah R, Arduini F, Amine A, Giardi MT, Scognamiglio V. A dual electro-optical biosensor based on Chlamydomonas reinhardtii immobilised on paper-based nanomodified screen-printed electrodes for herbicide monitoring. J Nanobiotechnology 2021; 19:145. [PMID: 34001124 PMCID: PMC8130446 DOI: 10.1186/s12951-021-00887-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 05/07/2021] [Indexed: 11/24/2022] Open
Abstract
The indiscriminate use of herbicides in agriculture contributes to soil and water pollution, with important endangering consequences on the ecosystems. Among the available analytical systems, algal biosensors have demonstrated to be valid tools thanks to their high sensitivity, cost-effectiveness, and eco-design. Herein, we report the development of a dual electro-optical biosensor for herbicide monitoring, based on Chlamydomonas reinhardtii whole cells immobilised on paper-based screen-printed electrodes modified with carbon black nanomaterials. To this aim, a systematic study was performed for the selection and characterisation of a collection among 28 different genetic variants of the alga with difference response behaviour towards diverse herbicide classes. Thus, CC125 strain was exploited as case study for the study of the analytical parameters. The biosensor was tested in standard solutions and real samples, providing high sensitivity (detection limit in the pico/nanomolar), high repeatability (RSD of 5% with n = 100), long lasting working (10 h) and storage stability (3 weeks), any interference in the presence of heavy metals and insecticides, and low matrix effect in drinking water and moderate effect in surface one.
![]()
Collapse
Affiliation(s)
- Amina Antonacci
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography, National Research Council, Via Salaria km 29.300, Monterotondo, 00015, Rome, Italy
| | - Raouia Attaallah
- Faculty of Sciences and Techniques, Hassan II University of Casablanca, Casablanca, Morocco
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133, Rome, Italy.,SENSE4MED, Via Renato Rascel 30, 00128, Rome, Italy
| | - Aziz Amine
- Faculty of Sciences and Techniques, Hassan II University of Casablanca, Casablanca, Morocco
| | - Maria Teresa Giardi
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography, National Research Council, Via Salaria km 29.300, Monterotondo, 00015, Rome, Italy.,Biosensor Srl, Via degli Olmetti 44, Formello, 00060, Rome, Italy
| | - Viviana Scognamiglio
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography, National Research Council, Via Salaria km 29.300, Monterotondo, 00015, Rome, Italy.
| |
Collapse
|
25
|
Application of botryosphaeran as a carbon black adherent on a glassy carbon electrode for the electrochemical determination of cyclobenzaprine. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138176] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
26
|
Camargo JR, Orzari LO, Araújo DAG, de Oliveira PR, Kalinke C, Rocha DP, Luiz dos Santos A, Takeuchi RM, Munoz RAA, Bonacin JA, Janegitz BC. Development of conductive inks for electrochemical sensors and biosensors. Microchem J 2021. [DOI: 10.1016/j.microc.2021.105998] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
27
|
Zhao K, Veksha A, Ge L, Lisak G. Near real-time analysis of para-cresol in wastewater with a laccase-carbon nanotube-based biosensor. CHEMOSPHERE 2021; 269:128699. [PMID: 33121813 DOI: 10.1016/j.chemosphere.2020.128699] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/13/2020] [Accepted: 10/16/2020] [Indexed: 06/11/2023]
Abstract
Para-Cresol is a water-soluble organic pollutant, which is harmful to organisms even at low concentrations. Therefore, it is important to rapidly detect the p-cresol in wastewater as well as natural water. In this work, a new, simple and stable biosensor was developed for on-site quantitatively determination and near real-time monitoring p-cresol in wastewater. The new biosensor was designed and fabricated using a screen-printed carbon electrode (SPCE) modified by waste-derived carbon nanotubes (CNTs) immobilized with laccase (LAC). The fabrication processes and performance of the biosensors were systematically characterized and optimized by Fourier transform infrared spectroscopy (FTIR), field emission scanning electron microscope (FESEM), transmission electron microscopy (TEM) and electrochemical methods. With improved conductivity, the proposed biosensor could provide the direct quantitation of p-cresol. The linear range of the biosensor is 0.2-25 ppm of p-cresol with a detection limit of 0.05 ppm. Additionally, the biosensor exhibited high reproducibility, stability and reusability during the validation. More importantly, the biosensor was successfully applied for the rapid detection of p-cresol in environmental lab wastewater under the interference of metal ions and other organics, and the results were consistent with high-performance liquid chromatography (HPLC). Finally, the biosensor with a portable potentiostat was approved as an easy-to-use, sensitive and inexpensive platform that could provide near real-time monitoring of p-cresol concentration in wastewater during Fenton oxidation treatment process.
Collapse
Affiliation(s)
- Ke Zhao
- Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore
| | - Andrei Veksha
- Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore
| | - Liya Ge
- Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore.
| | - Grzegorz Lisak
- Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, 637141, Singapore; School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore.
| |
Collapse
|
28
|
Nelis JLD, Migliorelli D, Mühlebach L, Generelli S, Stewart L, Elliott CT, Campbell K. Highly sensitive electrochemical detection of the marine toxins okadaic acid and domoic acid with carbon black modified screen printed electrodes. Talanta 2021; 228:122215. [PMID: 33773701 DOI: 10.1016/j.talanta.2021.122215] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 02/07/2021] [Accepted: 02/11/2021] [Indexed: 11/18/2022]
Abstract
A novel electrochemical immunosensor for the detection of the important marine biotoxins domoic acid (DA) and okadaic acid (OA) was developed. The sensors used carbon black modified screen-printed electrodes (CB-SPE) obtained using a high-throughput method. The electrochemical performance and stability of CB modified SPEs and bare carbon SPEs (c-SPEs) were compared using cyclic voltammetry and electrochemical impedance spectroscopy. CB-SPEs showed improved long-term (at least six months) stability and electro-catalytic properties compared with c-SPEs. The CB-SPEs were bio-functionalized with DA or OA protein-conjugates and used to develop two indirect competitive immunosensors using differential pulse voltammetry (DPV). The DPV signals obtained for the OA and DA immunosensors fitted well to four-parameter dose-response curves (R2 > 0.98) and showed excellent LODs (LOD = 1.7 ng mL-1 for DA in buffer; LOD = 1.9 ng mL-1 for DA in mussel extract; LOD = 0.15 ng mL-1 for OA in buffer; LOD = 0.18 ng mL-1 for OA in mussel extract). No significant interference of the naturally co-occurring marine toxins saxitoxin, tetrodotoxin and OA was detected for the DA immunosensor. Similarly, for the OA immunosensor saxitoxin, tetrodotoxin and DA did not cross-react and very limited interference was observed for the dinophysis toxins DTX-1, DTX-2 and DTX-3 (OA congeners). Moreover, both immunosensors remained stable after at least 25 days of storage at 4 °C. This work demonstrates the potential of affordable, mass-produced nanomaterial-modified SPEs for marine toxin detection in shellfish.
Collapse
Affiliation(s)
- Joost L D Nelis
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK.
| | | | - Lea Mühlebach
- CSEM SA, Bahnhofstrasse 1, 7302, Landquart, Switzerland
| | | | - Linda Stewart
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - Christopher T Elliott
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - Katrina Campbell
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| |
Collapse
|
29
|
Pradela-Filho LA, Araújo DAG, Takeuchi RM, Santos AL, Henry CS. Thermoplastic electrodes as a new electrochemical platform coupled to microfluidic devices for tryptamine determination. Anal Chim Acta 2021; 1147:116-123. [PMID: 33485570 DOI: 10.1016/j.aca.2020.12.059] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 11/19/2020] [Accepted: 12/27/2020] [Indexed: 01/24/2023]
Abstract
This study reports a new electrochemical method for tryptamine determination using a paper-based microfluidic device and a thermoplastic electrode (TPE) as an amperometric detector. Tryptamine (Tryp) is a biogenic amine present in drinks and foods. Even though this compound has some beneficial effects on human health, the ingestion of foods with high concentrations of Tryp may be detrimental, which justifies the need for monitoring the Tryp levels. The TPEs were made from 50% carbon black and 50% polycaprolactone and characterized by cyclic voltammetry, demonstrating enhancement in the analytical response compared to other carbon composites. TPEs also showed a better antifouling effect for Tryp compared to conventional glassy carbon electrodes. Once characterized, the electrodes were incorporated into the microfluidic device to determine Tryp in water and cheese samples using amperometry. A linear range was achieved from 10 to 75 μmol L-1 with limits of detection and quantification of 3.2 and 10.5 μmol L-1, respectively. Therefore, this work shows promising findings of the electrochemical determination of Tryp, bringing valuable results regarding the electrochemical properties of thermoplastic composites.
Collapse
Affiliation(s)
- Lauro A Pradela-Filho
- Institute of Chemistry, Federal University of Uberlandia, 38400-902, Uberlandia, Minas Gerais, Brazil; Institute of Exact and Natural Sciences of Pontal, Federal University of Uberlandia, 38304-402, Ituiutaba, Minas Gerais, Brazil
| | - Diele A G Araújo
- Institute of Chemistry, Federal University of Uberlandia, 38400-902, Uberlandia, Minas Gerais, Brazil; Institute of Exact and Natural Sciences of Pontal, Federal University of Uberlandia, 38304-402, Ituiutaba, Minas Gerais, Brazil
| | - Regina M Takeuchi
- Institute of Chemistry, Federal University of Uberlandia, 38400-902, Uberlandia, Minas Gerais, Brazil; Institute of Exact and Natural Sciences of Pontal, Federal University of Uberlandia, 38304-402, Ituiutaba, Minas Gerais, Brazil
| | - André L Santos
- Institute of Chemistry, Federal University of Uberlandia, 38400-902, Uberlandia, Minas Gerais, Brazil; Institute of Exact and Natural Sciences of Pontal, Federal University of Uberlandia, 38304-402, Ituiutaba, Minas Gerais, Brazil
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States.
| |
Collapse
|
30
|
Cirrincione M, Zanfrognini B, Pigani L, Protti M, Mercolini L, Zanardi C. Development of an electrochemical sensor based on carbon black for the detection of cannabidiol in vegetable extracts. Analyst 2021; 146:612-619. [DOI: 10.1039/d0an01932a] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A glassy carbon electrode chemically modified with a carbon black coating is proposed here for the rapid and portable determination of cannabidiol (CBD) in a commercial Cannabis seed oil and in fibre-type Cannabis sativa L. leaves.
Collapse
Affiliation(s)
- Marco Cirrincione
- Department of Pharmacy and Biotechnology
- Alma Mater Studiorum
- Università di Bologna
- 40126 Bologna
- Italy
| | - Barbara Zanfrognini
- Institute of Organic Synthesis and Photoreactivity (ISOF)
- National Research Council of Italy (CNR)
- 40129 Bologna
- Italy
| | - Laura Pigani
- Department of Chemical and Geological Sciences
- Università di Modena e Reggio Emilia
- 41125 Modena
- Italy
| | - Michele Protti
- Department of Pharmacy and Biotechnology
- Alma Mater Studiorum
- Università di Bologna
- 40126 Bologna
- Italy
| | - Laura Mercolini
- Department of Pharmacy and Biotechnology
- Alma Mater Studiorum
- Università di Bologna
- 40126 Bologna
- Italy
| | - Chiara Zanardi
- Institute of Organic Synthesis and Photoreactivity (ISOF)
- National Research Council of Italy (CNR)
- 40129 Bologna
- Italy
- Department of Chemical and Geological Sciences
| |
Collapse
|
31
|
Kava AA, Henry CS. Exploring carbon particle type and plasma treatment to improve electrochemical properties of stencil-printed carbon electrodes. Talanta 2021; 221:121553. [PMID: 33076109 PMCID: PMC7575823 DOI: 10.1016/j.talanta.2020.121553] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/08/2020] [Accepted: 08/10/2020] [Indexed: 12/20/2022]
Abstract
Stencil-printing conductive carbon inks has revolutionized the development of inexpensive, disposable and portable electrochemical sensors. However, stencil-printed carbon electrodes (SPCEs) typically suffer from poor electrochemical properties. While many surface pretreatments and modifications have been tested to improve the electrochemical activity of SPCEs, the bulk composition of the inks used for printing has been largely ignored. Recent studies of other carbon composite electrode materials show significant evidence that the conductive carbon particle component is strongly related to electrochemical performance. However, such a study has not been carried out with SPCEs. In this work, we perform a systematic characterization of SPCEs made with different carbon particle types including graphite particles, glassy carbon microparticles and carbon black. The relationship between carbon particle characteristics including particle size, particle purity, and particle morphology as well as particle mass loading on the fabrication and electrochemical properties of SPCEs is studied. SPCEs were plasma treated for surface activation and the electrochemical properties of both untreated and plasma treated SPCEs are also compared. SPCEs displayed distinct analytical utilities characterized through solvent window and double layer capacitance. Cyclic voltammetry (CV) of several standard redox probes, FcTMA+, ferri/ferrocyanide, and pAP was used to establish the effects of carbon particle type and plasma treatment on electron transfer kinetics of SPCEs. CV of the biologically relevant molecules uric acid, NADH and dopamine was employed to further illustrate the differences in sensing and fouling characteristics of SPCEs fabricated with different carbon particle types. SEM imaging revealed significant differences in the SPCE surface microstructures. This systematic study demonstrates that the electrochemical properties of SPCEs can be tuned and significantly improved through careful selection of carbon particle type and plasma cleaning with a goal toward the development of better performing electrochemical point-of-need sensors.
Collapse
Affiliation(s)
- Alyssa A Kava
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, United States.
| |
Collapse
|
32
|
Fabiani L, Saroglia M, Galatà G, De Santis R, Fillo S, Luca V, Faggioni G, D'Amore N, Regalbuto E, Salvatori P, Terova G, Moscone D, Lista F, Arduini F. Magnetic beads combined with carbon black-based screen-printed electrodes for COVID-19: A reliable and miniaturized electrochemical immunosensor for SARS-CoV-2 detection in saliva. Biosens Bioelectron 2021; 171:112686. [PMID: 33086175 PMCID: PMC7833515 DOI: 10.1016/j.bios.2020.112686] [Citation(s) in RCA: 288] [Impact Index Per Article: 72.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/28/2020] [Accepted: 10/02/2020] [Indexed: 12/11/2022]
Abstract
The diffusion of novel SARS-CoV-2 coronavirus over the world generated COVID-19 pandemic event as reported by World Health Organization on March 2020. The huge issue is the high infectivity and the absence of vaccine and customised drugs allowing for hard management of this outbreak, thus a rapid and on site analysis is a need to contain the spread of COVID-19. Herein, we developed an electrochemical immunoassay for rapid and smart detection of SARS-CoV-2 coronavirus in saliva. The electrochemical assay was conceived for Spike (S) protein or Nucleocapsid (N) protein detection using magnetic beads as support of immunological chain and secondary antibody with alkaline phosphatase as immunological label. The enzymatic by-product 1-naphtol was detected using screen-printed electrodes modified with carbon black nanomaterial. The analytical features of the electrochemical immunoassay were evaluated using the standard solution of S and N protein in buffer solution and untreated saliva with a detection limit equal to 19 ng/mL and 8 ng/mL in untreated saliva, respectively for S and N protein. Its effectiveness was assessed using cultured virus in biosafety level 3 and in saliva clinical samples comparing the data using the nasopharyngeal swab specimens tested with Real-Time PCR. The agreement of the data, the low detection limit achieved, the rapid analysis (30 min), the miniaturization, and portability of the instrument combined with the easiness to use and no-invasive sampling, confer to this analytical tool high potentiality for market entry as the first highly sensitive electrochemical immunoassay for SARS-CoV-2 detection in untreated saliva.
Collapse
Affiliation(s)
- Laura Fabiani
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Marco Saroglia
- University of Insubria, Department of Biotechnologies and Life Sciences, Varese, Italy
| | - Giuseppe Galatà
- GTS Consulting S.r.l., Via Consolare Pompea 1, 98168, Messina, Italy
| | | | - Silvia Fillo
- Scientific Department, Army Medical Center, Rome, Italy
| | - Vincenzo Luca
- Scientific Department, Army Medical Center, Rome, Italy
| | | | - Nino D'Amore
- Scientific Department, Army Medical Center, Rome, Italy
| | | | | | - Genciana Terova
- University of Insubria, Department of Biotechnologies and Life Sciences, Varese, Italy
| | - Danila Moscone
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133, Rome, Italy
| | | | - Fabiana Arduini
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133, Rome, Italy; SENSE4MED, Via Renato Rascel 30, 00128, Rome, Italy.
| |
Collapse
|
33
|
Bounegru AV, Apetrei C. Voltamperometric Sensors and Biosensors Based on Carbon Nanomaterials Used for Detecting Caffeic Acid-A Review. Int J Mol Sci 2020; 21:E9275. [PMID: 33291758 PMCID: PMC7730703 DOI: 10.3390/ijms21239275] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/01/2020] [Accepted: 12/02/2020] [Indexed: 12/11/2022] Open
Abstract
Caffeic acid is one of the most important hydroxycinnamic acids found in various foods and plant products. It has multiple beneficial effects in the human body such as antioxidant, antibacterial, anti-inflammatory, and antineoplastic. Since overdoses of caffeic acid may have negative effects, the quality and quantity of this acid in foods, pharmaceuticals, food supplements, etc., needs to be accurately determined. The present paper analyzes the most representative scientific papers published mostly in the last 10 years which describe the development and characterization of voltamperometric sensors or biosensors based on carbon nanomaterials and/or enzyme commonly used for detecting caffeic acid and a series of methods which may improve the performance characteristics of such sensors.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galaţi, 47 Domnească Street, 800008 Galaţi, Romania;
| |
Collapse
|
34
|
Preparation and characterization of reusable Sonogel-Carbon electrodes containing carbon black: Application as amperometric sensors for determination of cathecol. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114653] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
35
|
Laser scribed graphene: A novel platform for highly sensitive detection of electroactive biomolecules. Biosens Bioelectron 2020; 168:112509. [DOI: 10.1016/j.bios.2020.112509] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/03/2020] [Accepted: 08/09/2020] [Indexed: 01/05/2023]
|
36
|
Printing-Based Assay and Therapy of Antioxidants. Antioxidants (Basel) 2020; 9:antiox9111052. [PMID: 33126547 PMCID: PMC7692755 DOI: 10.3390/antiox9111052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/18/2020] [Accepted: 10/26/2020] [Indexed: 12/21/2022] Open
Abstract
Antioxidants are essential in regulating various physiological functions and oxidative deterioration. Over the past decades, many researchers have paid attention to antioxidants and studied the screening of antioxidants from natural products and their utilization for treatments in diverse pathological conditions. Nowadays, as printing technology progresses, its influence in the field of biomedicine is growing significantly. The printing technology has many advantages. Especially, the capability of designing sophisticated platforms is useful to detect antioxidants in various samples. The high flexibility of 3D printing technology is advantageous to create geometries for customized patient treatment. Recently, there has been increasing use of antioxidant materials for this purpose. This review provides a comprehensive overview of recent advances in printing technology-based assays to detect antioxidants and 3D printing-based antioxidant therapy in the field of tissue engineering. This review is divided into two sections. The first section highlights colorimetric assays using the inkjet-printing methods and electrochemical assays using screen-printing techniques for the determination of antioxidants. Alternative screen-printing techniques, such as xurography, roller-pen writing, stamp contact printing, and laser-scribing, are described. The second section summarizes the recent literature that reports antioxidant-based therapy using 3D printing in skin therapeutics, tissue mimetic 3D cultures, and bone tissue engineering.
Collapse
|
37
|
Mazzaracchio V, Tshwenya L, Moscone D, Arduini F, Arotiba OA. A Poly(Propylene Imine) Dendrimer and Carbon Black Modified Flexible Screen Printed Electrochemical Sensor for Lead and Cadmium Co‐detection. ELECTROANAL 2020. [DOI: 10.1002/elan.202060284] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Vincenzo Mazzaracchio
- University of Rome “Tor Vergata” Department of Chemical Science and Technologies Via della Ricerca Scientifica 00133 Rome Italy
- Department of Chemical Sciences University of Johannesburg Doornfontein Johannesburg South Africa (Formerly known as The Department of Applied Chemistry, University of Johannesburg, Doornfontein, Johannesburg, South Africa
| | - Luthando Tshwenya
- Department of Chemical Sciences University of Johannesburg Doornfontein Johannesburg South Africa (Formerly known as The Department of Applied Chemistry, University of Johannesburg, Doornfontein, Johannesburg, South Africa
| | - Danila Moscone
- University of Rome “Tor Vergata” Department of Chemical Science and Technologies Via della Ricerca Scientifica 00133 Rome Italy
| | - Fabiana Arduini
- University of Rome “Tor Vergata” Department of Chemical Science and Technologies Via della Ricerca Scientifica 00133 Rome Italy
| | - Omotayo A. Arotiba
- Department of Chemical Sciences University of Johannesburg Doornfontein Johannesburg South Africa (Formerly known as The Department of Applied Chemistry, University of Johannesburg, Doornfontein, Johannesburg, South Africa
- Centre for Nanomaterials Science Research University of Johannesburg South Africa
| |
Collapse
|
38
|
MOF-818 metal-organic framework-reduced graphene oxide/multiwalled carbon nanotubes composite for electrochemical sensitive detection of phenolic acids. Talanta 2020; 218:121123. [DOI: 10.1016/j.talanta.2020.121123] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Revised: 04/29/2020] [Accepted: 05/03/2020] [Indexed: 01/23/2023]
|
39
|
Forzato C, Vida V, Berti F. Biosensors and Sensing Systems for Rapid Analysis of Phenolic Compounds from Plants: A Comprehensive Review. BIOSENSORS 2020; 10:E105. [PMID: 32846992 PMCID: PMC7557957 DOI: 10.3390/bios10090105] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/18/2020] [Accepted: 08/21/2020] [Indexed: 01/18/2023]
Abstract
Phenolic compounds are secondary metabolites frequently found in plants that exhibit many different effects on human health. Because of the relevant bioactivity, their identification and quantification in agro-food matrices as well as in biological samples are a fundamental issue in the field of quality control of food and food supplements, and clinical analysis. In this review, a critical selection of sensors and biosensors for rapid and selective detection of phenolic compounds is discussed. Sensors based on electrochemistry, photoelectrochemistry, fluorescence, and colorimetry are discussed including devices with or without specific recognition elements, such as biomolecules, enzymes and molecularly imprinted materials. Systems that have been tested on real matrices are prevalently considered but also techniques that show potential development in the field.
Collapse
Affiliation(s)
| | | | - Federico Berti
- Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, via Giorgieri 1, 34127 Trieste, Italy; (C.F.); (V.V.)
| |
Collapse
|
40
|
Hashim HS, Fen YW, Sheh Omar NA, Abdullah J, Daniyal WMEMM, Saleviter S. Detection of phenol by incorporation of gold modified-enzyme based graphene oxide thin film with surface plasmon resonance technique. OPTICS EXPRESS 2020; 28:9738-9752. [PMID: 32225575 DOI: 10.1364/oe.387027] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Accepted: 02/01/2020] [Indexed: 06/10/2023]
Abstract
In this study, the incorporation between gold modified-tyrosinase (Tyr) enzyme based graphene oxide (GO) thin film with surface plasmon resonance (SPR) technique has been developed for the detection of phenol. SPR signal for the thin film contacted with phenol solution was monitored using SPR technique. From the SPR curve, sensitivity, full width at half maximum (FWHM), detection accuracy (DA) and signal-to-noise ratio (SNR) have been analyzed. The sensor produces a linear response for phenol up to 100 µM with sensitivity of 0.00193° µM-1. Next, it can be observed that deionized water has the lowest FWHM, with a value of 1.87° and also the highest value of DA. Besides, the SNR of the SPR signal was proportional to the phenol concentrations. Furthermore, the surface morphology of the modified thin film after exposed with phenol solution observed using atomic force microscopy showed a lot of sharp peaks compared to the image before in contact with phenol proved the interaction between the thin film and phenol.
Collapse
|
41
|
Jemmeli D, Marcoccio E, Moscone D, Dridi C, Arduini F. Highly sensitive paper-based electrochemical sensor for reagent free detection of bisphenol A. Talanta 2020; 216:120924. [PMID: 32456933 DOI: 10.1016/j.talanta.2020.120924] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 03/10/2020] [Accepted: 03/11/2020] [Indexed: 11/26/2022]
Abstract
Bisphenol A is one the most relevant endocrine disruptors for its toxicity and ubiquity in the environment, being largely employed as raw material for manufacturing processes of a wide number of compounds. Furthermore, bisphenol A is released in the drinking water when plastic-based bottles are incorrectly transported under sunlight, delivering contaminated drinking water. For the health of human beings and the environment, rapid and on site detection of bisphenol A in drinking water is an important issue. Herein, we report a novel and cost-effective printed electrochemical sensor for an enzymatic-free bisphenol A detection. This sensor encompasses the entire electrochemical cell printed on filter paper and the reagents for the measurement loaded in the cellulose fiber network, for delivering a reagent-free analytical tool. The working electrode was printed using ink modified with carbon black, a cost effective nanomaterial for sensitive and sustainable bisphenol A determination. Several parameters including pH, frequency, and amplitude were optimized allowing for a detection limit of 0.03 μM with two linear ranges 0.1-0.9 μM and 1 μM-50 μM, using square wave voltammetry as electrochemical technique. The satisfactory recovery values found in river and drinking water samples demonstrated the suitability of this sensor for screening analyses in water samples. These results revealed the attractiveness of this paper-based device thanks to the synergic combination of paper and carbon black as cost-effective materials.
Collapse
Affiliation(s)
- Dhouha Jemmeli
- NANOMISENE Laboratory LR16CRMN01, Center for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse, B.P334, 4054, Sahloul Sousse, Tunisia
| | - Eleonora Marcoccio
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Danila Moscone
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Cherif Dridi
- NANOMISENE Laboratory LR16CRMN01, Center for Research on Microelectronics and Nanotechnology of Sousse, Technopole of Sousse, B.P334, 4054, Sahloul Sousse, Tunisia
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy; SENSE4MED via Renato Rascel 30, 00128, Rome, Italy.
| |
Collapse
|
42
|
Ge L, Li SP, Lisak G. Advanced sensing technologies of phenolic compounds for pharmaceutical and biomedical analysis. J Pharm Biomed Anal 2020; 179:112913. [DOI: 10.1016/j.jpba.2019.112913] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 09/10/2019] [Accepted: 10/05/2019] [Indexed: 11/17/2022]
|
43
|
Arduini F, Cinti S, Mazzaracchio V, Scognamiglio V, Amine A, Moscone D. Carbon black as an outstanding and affordable nanomaterial for electrochemical (bio)sensor design. Biosens Bioelectron 2020; 156:112033. [PMID: 32174547 DOI: 10.1016/j.bios.2020.112033] [Citation(s) in RCA: 105] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 01/06/2020] [Accepted: 01/15/2020] [Indexed: 12/17/2022]
Abstract
Advances in cutting-edge technologies including nanotechnology, microfluidics, electronic engineering, and material science have boosted a new era in the design of robust and sensitive biosensors. In recent years, carbon black has been re-discovered in the design of electrochemical (bio)sensors thanks to its interesting electroanalytical properties, absence of treatment requirement, cost-effectiveness (c.a. 1 €/Kg), and easiness in the preparation of stable dispersions. Herein, we present an overview of the literature on carbon black-based electrochemical (bio)sensors, highlighting current trends and possible challenges to this rapidly developing area, with a special focus on the fabrication of carbon black-based electrodes in the realisation of sensors and biosensors (e.g. enzymatic, immunosensors, and DNA-based).
Collapse
Affiliation(s)
- Fabiana Arduini
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133, Rome, Italy; SENSE4MED via Renato Rascel 30, 00128, Rome, Italy.
| | - Stefano Cinti
- University of Naples Federico II, Department of Pharmacy, Naples, Italy
| | - Vincenzo Mazzaracchio
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Viviana Scognamiglio
- Institute of Crystallography, Department of Chemical Sciences and Materials Technologies, Via Salaria Km 29.3, 00015, Monterotondo Scalo, Rome, Italy
| | - Aziz Amine
- Faculty of Sciences and Techniques, Hassan II University of Casablanca, Morocco
| | - Danila Moscone
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133, Rome, Italy
| |
Collapse
|
44
|
Tomei MR, Marcoccio E, Neagu D, Moscone D, Arduini F. A Miniaturized Carbon Black‐based Electrochemical Sensor for Chlorine Dioxide Detection in Swimming Pool Water. ELECTROANAL 2020. [DOI: 10.1002/elan.201900667] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
| | - Eleonora Marcoccio
- Department of Chemical Science and Technologies University of Rome “Tor Vergata” Via della Ricerca Scientifica 00133 Rome Italy
| | - Daniela Neagu
- TecnoSens srl Via Francesco Antolisei 25 00173 Rome Italy
| | - Danila Moscone
- Department of Chemical Science and Technologies University of Rome “Tor Vergata” Via della Ricerca Scientifica 00133 Rome Italy
| | - Fabiana Arduini
- Department of Chemical Science and Technologies University of Rome “Tor Vergata” Via della Ricerca Scientifica 00133 Rome Italy
- SENSE4MED srl Via Renato Rascel 30 00128 Rome Italy
| |
Collapse
|
45
|
Abstract
This chapter deals with the advancement of nanomaterial-based sensors in the last 10 years. The use of different types of nanomaterials, including graphene, carbon nanotubes, and metallic nanoparticles, was described, highlighting that graphene represents a rising star in the plethora of nanomaterials. Among the different transducers, the chapter describes the electrochemical and optical (bio)sensors, being the most promising devices. The use of materials at the nanodimension scale provides several improvements in terms of analytical features including sensitivity, rapidity of response, selectivity, and robustness, demonstrating the huge advantage of using the nanomaterials over the micromaterials in the development of smart and high-performant analytical tools.
Collapse
|
46
|
Wong A, Santos AM, Cincotto FH, Moraes FC, Fatibello-Filho O, Sotomayor MD. A new electrochemical platform based on low cost nanomaterials for sensitive detection of the amoxicillin antibiotic in different matrices. Talanta 2020; 206:120252. [DOI: 10.1016/j.talanta.2019.120252] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 08/09/2019] [Accepted: 08/10/2019] [Indexed: 12/20/2022]
|
47
|
Castrovilli MC, Bolognesi P, Chiarinelli J, Avaldi L, Calandra P, Antonacci A, Scognamiglio V. The convergence of forefront technologies in the design of laccase-based biosensors – An update. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.07.026] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
48
|
Mazzaracchio V, Tomei MR, Cacciotti I, Chiodoni A, Novara C, Castellino M, Scordo G, Amine A, Moscone D, Arduini F. Inside the different types of carbon black as nanomodifiers for screen-printed electrodes. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.05.117] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
49
|
A novel microbial - Bioelectrochemical sensor for the detection of n-cyclohexyl-2-pyrrolidone in wastewater. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.06.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
50
|
Rojas D, Della Pelle F, Del Carlo M, Fratini E, Escarpa A, Compagnone D. Nanohybrid carbon black-molybdenum disulfide transducers for preconcentration-free voltammetric detection of the olive oil o-diphenols hydroxytyrosol and oleuropein. Mikrochim Acta 2019; 186:363. [PMID: 31104163 DOI: 10.1007/s00604-019-3418-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Accepted: 04/05/2019] [Indexed: 11/26/2022]
Abstract
A new hybrid nanomaterial is used in a screen-printed electrode (SPE) for sensing of the ortho-diphenols oleuropein (OLEU) and hydroxytyrosol (HYT) in extra virgin olive oil (EVOO) and related samples. The hybrid material consists of carbon black (CB) and molybdenum disulfide (MoS2). In comparison with individual nanomaterials, CB-MoS2 exhibits improved charge-transfer ability, low charge-transfer resistance, high electrical conductivity and enhanced electrocatalysis. The sensor is also characterized by (a) high sensitivity that avoids the need for adsorptive voltammetry, (b) reduced analysis time, and (c) high anti-fouling ability (electrode RSDOLEU < 8%, for n = 10). OLEU can be detected in the 0.3 to 30 μM concentration range with a 0.1 μM LOD, and HYT in the 2-100 μM range with a 1 μM LOD. A comparison of the data obtained by this sensor and by HPLC-UV exhibited high correlation (r = 0.995, p < 0.05). These data revealed the reliability of CB-MoS2 for analysis of complex EVOO and related samples. Graphical abstract CB-MoS2-based electrochemical sensor for fast and reliable assessment of total ortho-diphenols antioxidants in olive oils.
Collapse
Affiliation(s)
- Daniel Rojas
- Faculty of Bioscience and Technology for Food, Agriculture and Environment University of Teramo, 64023, Teramo, Italy
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, E-28871, Madrid, Spain
| | - Flavio Della Pelle
- Faculty of Bioscience and Technology for Food, Agriculture and Environment University of Teramo, 64023, Teramo, Italy
| | - Michele Del Carlo
- Faculty of Bioscience and Technology for Food, Agriculture and Environment University of Teramo, 64023, Teramo, Italy
| | - Emiliano Fratini
- Department of Chemistry "Ugo Schiff" and CSGI, University of Florence, via della Lastruccia 3 Sesto Fiorentino, I-50019, Florence, Italy
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, E-28871, Madrid, Spain.
- Chemical Research Institute "Andres M. del Rio", University of Alcalá, E-28871, Madrid, Spain.
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment University of Teramo, 64023, Teramo, Italy.
| |
Collapse
|