1
|
Biswas AA, Dhondale MR, Singh M, Agrawal AK, Muthudoss P, Mishra B, Kumar D. Development and comparison of machine learning models for in-vitro drug permeation prediction from microneedle patch. Eur J Pharm Biopharm 2024; 199:114311. [PMID: 38710374 DOI: 10.1016/j.ejpb.2024.114311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 04/16/2024] [Accepted: 05/03/2024] [Indexed: 05/08/2024]
Abstract
The field of machine learning (ML) is advancing to a larger extent and finding its applications across numerous fields. ML has the potential to optimize the development process of microneedle patch by predicting the drug release pattern prior to its fabrication and production. The early predictions could not only assist the in-vitro and in-vivo experimentation of drug release but also conserve materials, reduce cost, and save time. In this work, we have used a dataset gleaned from the literature to train and evaluate different ML models, such as stacking regressor, artificial neural network (ANN) model, and voting regressor model. In this study, models were developed to improve prediction accuracy of the in-vitro drug release amount from the hydrogel-type microneedle patch and the in-vitro drug permeation amount through the micropores created by solid microneedles on the skin. We compared the performance of these models using various metrics, including R-squared score (R2 score), root mean squared error (RMSE), and mean absolute error (MAE). Voting regressor model performed better with drug permeation percentage as an outcome feature having RMSE value of 3.24. In comparison, stacking regressor have a RMSE value of 16.54, and ANN model has shown a RMSE value of 14. The value of permeation amount calculated from the predicted percentage is found to be more accurate with RMSE of 654.94 than direct amount prediction, having a RMSE of 669.69. All our models have performed far better than the previously developed model before this research, which had a RMSE of 4447.23. We then optimized voting regressor model's hyperparameter and cross validated its performance. Furthermore, it was deployed in a webapp using Flask framework, showing a way to develop an application to allow other users to easily predict drug permeation amount from the microneedle patch at a particular time period. This project demonstrates the potential of ML to facilitate the development of microneedle patch and other drug delivery systems.
Collapse
Affiliation(s)
- Anuj A Biswas
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India.
| | - Madhukiran R Dhondale
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India.
| | - Maan Singh
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India.
| | - Ashish K Agrawal
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India.
| | - Prakash Muthudoss
- A2Z4.0 Research and Analytics Private Limited, Chennai 600062, Tamilnadu, India; NuAxon Bioscience Inc., Bloomington, IN 47401-6301, USA; School of Pharmaceutical Sciences, Vels Institute of Science, Technology & Advanced Studies (VISTAS), Velan Nagar P.V. Vaithiyalingam Road Pallavaram, 600117 Chennai, Tamilnadu, India.
| | - Brahmeshwar Mishra
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India.
| | - Dinesh Kumar
- Department of Pharmaceutical Engineering and Technology, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh, India.
| |
Collapse
|
2
|
Khairnar P, Phatale V, Shukla S, Tijani AO, Hedaoo A, Strauss J, Verana G, Vambhurkar G, Puri A, Srivastava S. Nanocarrier-Integrated Microneedles: Divulging the Potential of Novel Frontiers for Fostering the Management of Skin Ailments. Mol Pharm 2024; 21:2118-2147. [PMID: 38660711 DOI: 10.1021/acs.molpharmaceut.4c00144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
The various kinds of nanocarriers (NCs) have been explored for the delivery of therapeutics designed for the management of skin manifestations. The NCs are considered as one of the promising approaches for the skin delivery of therapeutics attributable to sustained release and enhanced skin penetration. Despite the extensive applications of the NCs, the challenges in their delivery via skin barrier (majorly stratum corneum) have persisted. To overcome all the challenges associated with the delivery of NCs, the microneedle (MN) technology has emerged as a beacon of hope. Programmable drug release, being painless, and its minimally invasive nature make it an intriguing strategy to circumvent the multiple challenges associated with the various drug delivery systems. The integration of positive traits of NCs and MNs boosts therapeutic effectiveness by evading stratum corneum, facilitating the delivery of NCs through the skin and enhancing their targeted delivery. This review discusses the barrier function of skin, the importance of MNs, the types of MNs, and the superiority of NC-loaded MNs. We highlighted the applications of NC-integrated MNs for the management of various skin ailments, combinational drug delivery, active targeting, in vivo imaging, and as theranostics. The clinical trials, patent portfolio, and marketed products of drug/NC-integrated MNs are covered. Finally, regulatory hurdles toward benchtop-to-bedside translation, along with promising prospects needed to scale up NC-integrated MN technology, have been deliberated. The current review is anticipated to deliver thoughtful visions to researchers, clinicians, and formulation scientists for the successful development of the MN-technology-based product by carefully optimizing all the formulation variables.
Collapse
Affiliation(s)
- Pooja Khairnar
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, Telangana 500037, India
| | - Vivek Phatale
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, Telangana 500037, India
| | - Shalini Shukla
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, Telangana 500037, India
| | - Akeemat O Tijani
- Department of Pharmaceutical Sciences, Bill Gatton College of Pharmacy, East Tennessee State University, Johnson City, Tennessee 37614, United States
| | - Aachal Hedaoo
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, Telangana 500037, India
| | - Jordan Strauss
- Department of Pharmaceutical Sciences, Bill Gatton College of Pharmacy, East Tennessee State University, Johnson City, Tennessee 37614, United States
| | - Gabrielle Verana
- Department of Pharmaceutical Sciences, Bill Gatton College of Pharmacy, East Tennessee State University, Johnson City, Tennessee 37614, United States
| | - Ganesh Vambhurkar
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, Telangana 500037, India
| | - Ashana Puri
- Department of Pharmaceutical Sciences, Bill Gatton College of Pharmacy, East Tennessee State University, Johnson City, Tennessee 37614, United States
| | - Saurabh Srivastava
- Pharmaceutical Innovation and Translational Research Lab (PITRL), Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad, Telangana 500037, India
| |
Collapse
|
3
|
Anjani QK, Nainggolan ADC, Li H, Miatmoko A, Larrañeta E, Donnelly RF. Parafilm® M and Strat-M® as skin simulants in in vitro permeation of dissolving microarray patches loaded with proteins. Int J Pharm 2024; 655:124071. [PMID: 38554738 DOI: 10.1016/j.ijpharm.2024.124071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 03/27/2024] [Accepted: 03/28/2024] [Indexed: 04/02/2024]
Abstract
In vitro permeation studies play a crucial role in early formulation optimisation before extensive animal model investigations. Biological membranes are typically used in these studies to mimic human skin conditions accurately. However, when focusing on protein and peptide transdermal delivery, utilising biological membranes can complicate analysis and quantification processes. This study aims to explore Parafilm®M and Strat-M® as alternatives to dermatomed porcine skin for evaluating protein delivery from dissolving microarray patch (MAP) platforms. Initially, various MAPs loaded with different model proteins (ovalbumin, bovine serum albumin and amniotic mesenchymal stem cell metabolite products) were prepared. These dissolving MAPs underwent evaluation for insertion properties and in vitro permeation profiles when combined with different membranes, dermatomed porcine skin, Parafilm®M, and Strat-M®. Insertion profiles indicated that both Parafilm®M and Strat-M® showed comparable insertion depths to dermatomed porcine skin (in range of 360-430 µm), suggesting promise as membrane substitutes for insertion studies. In in vitro permeation studies, synthetic membranes such as Parafilm®M and Strat-M® demonstrated the ability to bypass protein-derived skin interference, providing more reliable results compared to dermatomed neonatal porcine skin. Consequently, these findings present valuable tools for preliminary screening across various MAP formulations, especially in the transdermal delivery of proteins and peptides.
Collapse
Affiliation(s)
- Qonita Kurnia Anjani
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK; Fakultas Farmasi, Universitas Megarezky, Jl. Antang Raya No. 43, Makassar 90234, Indonesia
| | | | - Huanhuan Li
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Andang Miatmoko
- Faculty of Pharmacy, Airlangga University, Nanizar Zaman Joenoes Building, Campus C, Mulyorejo, Surabaya 60115, Indonesia; Stem Cell Research and Development Center, Airlangga University, Institute of Tropical Disease Building, Campus C, Mulyorejo, Surabaya 60115, Indonesia
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK.
| |
Collapse
|
4
|
Li H, Anjani QK, Hutton ARJ, Paris JL, Moreno-Castellanos N, Himawan A, Larrañeta E, Donnelly RF. Design of a Novel Delivery Efficiency Feedback System for Biphasic Dissolving Microarray Patches Based on Poly(Lactic Acid) and Moisture-Indicating Silica. Adv Healthc Mater 2024:e2304082. [PMID: 38471772 DOI: 10.1002/adhm.202304082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/16/2024] [Indexed: 03/14/2024]
Abstract
Dissolving microarray patches (DMAPs) represent an innovative approach to minimally invasive transdermal drug delivery, demonstrating efficacy in delivering both small and large therapeutic molecules. However, concerns raised in end-user surveys have hindered their commercialization efforts. One prevalent issue highlighted in these surveys is the lack of clear indicators for successful patch insertion and removal time. To address this challenge, a color-change-based feedback system is devised, which confirms the insertion and dissolution of DMAPs, aiming to mitigate the aforementioned problems. The approach combines hydrophilic needles containing model drugs (fluorescein sodium and fluorescein isothiocyanate (FITC)-dextran) with a hydrophobic poly(lactic acid) baseplate infused with moisture-sensitive silica gel particles. The successful insertion and subsequent complete dissolution of the needle shaft are indicated by the progressive color change of crystal violet encapsulated in the silica. Notably, distinct color alterations on the baseplate, observed 30 min and 1 h after insertion for FITC-dextran and fluorescein sodium DMAPs respectively, signal the full dissolution of the needles, confirming the complete cargo delivery and enabling timely patch removal. This innovative feedback system offers a practical solution for addressing end-user concerns and may significantly contribute to the successful commercialization of DMAPs by providing a visualized drug delivery method.
Collapse
Affiliation(s)
- Huanhuan Li
- School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK
| | | | - Aaron R J Hutton
- School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK
| | - Juan Luis Paris
- School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK
- Instituto de Investigación Biomédica de Málaga y Plataforma en Nanomedicina-IBIMA Plataforma BIONAND, Málaga, 29590, Spain
| | - Natalia Moreno-Castellanos
- Basic Science Department, Faculty of Health, Universidad Industrial de Santander, Bucaramanga, 680001, Colombia
| | - Achmad Himawan
- School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK
- Department of Pharmaceutical Science and Technology, Faculty of Pharmacy, Universitas Hasanuddin, Makassar, 90245, Indonesia
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK
| |
Collapse
|
5
|
Martínez-Navarrete M, Guillot AJ, Lobita MC, Recio MC, Giner R, Aparicio-Blanco J, Montesinos MC, Santos HA, Melero A. Cyclosporin A-loaded dissolving microneedles for dermatitis therapy: Development, characterisation and efficacy in a delayed-type hypersensitivity in vivo model. Drug Deliv Transl Res 2024:10.1007/s13346-024-01542-9. [PMID: 38472726 DOI: 10.1007/s13346-024-01542-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2024] [Indexed: 03/14/2024]
Abstract
Several drugs can be used for treating inflammatory skin pathologies like dermatitis and psoriasis. However, for the management of chronic and long-term cases, topical administration is preferred over oral delivery since it prevents certain issues due to systemic side effects from occurring. Cyclosporin A (CsA) has been used for this purpose; however, its high molecular weight (1202 Da) restricts the diffusion through the skin structure. Here, we developed a nano-in-micro device combining lipid vesicles (LVs) and dissolving microneedle array patches (DMAPs) for targeted skin delivery. CsA-LVs allowed the effective incorporation of CsA in the hydrophilic DMAP matrix despite the hydrophobicity of the drug. Polymeric matrix composed of poly (vinyl alcohol) (5% w/v), poly (vinyl pyrrolidine) (15% w/v) and CsA-LV dispersion (10% v/v) led to the formation of CsA-LVs@DMAPs with adequate mechanical properties to penetrate the stratum corneum barrier. The safety and biocompatibility were ensured in an in vitro viability test using HaCaT keratinocytes and L929 fibroblast cell lines. Ex vivo permeability studies in a Franz-diffusion cell setup showed effective drug retention in the skin structure. Finally, CsA-LVs@DMAPs were challenged in an in vivo murine model of delayed-type hypersensitivity to corroborate their potential to ameliorate skin inflammatory conditions. Different findings like photon emission reduction in bioluminescence study, normalisation of histological damage and decrease of inflammatory cytokines point out the effectivity of CsA-LVs@DMAPs to treat these conditions. Overall, our study demonstrates that CsA-LVs@DMAPs can downregulate the skin inflammatory environment which paves the way for their clinical translation and their use as an alternative to corticosteroid-based therapies.
Collapse
Affiliation(s)
- Miquel Martínez-Navarrete
- Department of Pharmacy and Pharmaceutical Technology and Parasitology, University of Valencia, Ave. Vicent Andrés Estellés s/n, 46100, Burjassot, Valencia, Spain
| | - Antonio José Guillot
- Department of Pharmacy and Pharmaceutical Technology and Parasitology, University of Valencia, Ave. Vicent Andrés Estellés s/n, 46100, Burjassot, Valencia, Spain.
- Department of Biomaterials and Biomedical Technology, University Medical Center Groningen, University of Groningen, Ant. Deusinglaan 1, 9713 AV, Groningen, The Netherlands.
| | - Maria C Lobita
- Department of Biomaterials and Biomedical Technology, University Medical Center Groningen, University of Groningen, Ant. Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - María Carmen Recio
- Department of Pharmacology, University of Valencia, Ave. Vicent Andrés Estellés s/n, 46100, Burjassot, Valencia, Spain
| | - Rosa Giner
- Department of Pharmacology, University of Valencia, Ave. Vicent Andrés Estellés s/n, 46100, Burjassot, Valencia, Spain
| | - Juan Aparicio-Blanco
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, Complutense University of Madrid, Plaza Ramón y Cajal s/n, 28040, Madrid, Spain
| | - María Carmen Montesinos
- Department of Pharmacology, University of Valencia, Ave. Vicent Andrés Estellés s/n, 46100, Burjassot, Valencia, Spain
- Interuniversity Research Institute for Molecular Recognition and Technological Development (IDM), University of Valencia, Polytechnic University of Valencia, Valencia, Spain
| | - Hélder A Santos
- Department of Biomaterials and Biomedical Technology, University Medical Center Groningen, University of Groningen, Ant. Deusinglaan 1, 9713 AV, Groningen, The Netherlands
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, FI-00014, Helsinki, Finland
| | - Ana Melero
- Department of Pharmacy and Pharmaceutical Technology and Parasitology, University of Valencia, Ave. Vicent Andrés Estellés s/n, 46100, Burjassot, Valencia, Spain
| |
Collapse
|
6
|
Aldawood FK, Parupelli SK, Andar A, Desai S. 3D Printing of Biodegradable Polymeric Microneedles for Transdermal Drug Delivery Applications. Pharmaceutics 2024; 16:237. [PMID: 38399291 PMCID: PMC10893432 DOI: 10.3390/pharmaceutics16020237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/24/2024] [Accepted: 02/02/2024] [Indexed: 02/25/2024] Open
Abstract
Microneedle (MN) technology is an optimal choice for the delivery of drugs via the transdermal route, with a minimally invasive procedure. MN applications are varied from drug delivery, cosmetics, tissue engineering, vaccine delivery, and disease diagnostics. The MN is a biomedical device that offers many advantages including but not limited to a painless experience, being time-effective, and real-time sensing. This research implements additive manufacturing (AM) technology to fabricate MN arrays for advanced therapeutic applications. Stereolithography (SLA) was used to fabricate six MN designs with three aspect ratios. The MN array included conical-shaped 100 needles (10 × 10 needle) in each array. The microneedles were characterized using optical and scanning electron microscopy to evaluate the dimensional accuracy. Further, mechanical and insertion tests were performed to analyze the mechanical strength and skin penetration capabilities of the polymeric MN. MNs with higher aspect ratios had higher deformation characteristics suitable for penetration to deeper levels beyond the stratum corneum. MNs with both 0.3 mm and 0.4 mm base diameters displayed consistent force-displacement behavior during a skin-equivalent penetration test. This research establishes guidelines for fabricating polymeric MN for high-accuracy and low-cost 3D printing.
Collapse
Affiliation(s)
- Faisal Khaled Aldawood
- Department of Mechanical Engineering, College of Engineering, University of Bisha, P.O. Box 001, Bisha 67714, Saudi Arabia;
| | - Santosh Kumar Parupelli
- Center of Excellence in Product Design and Advanced Manufacturing, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA;
| | - Abhay Andar
- Champions Oncology, Inc., 1 University Plaza Dr, Hackensack, NJ 07601, USA;
| | - Salil Desai
- Center of Excellence in Product Design and Advanced Manufacturing, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA;
| |
Collapse
|
7
|
Nainggolan ADC, Anjani QK, Hartrianti P, Donnelly RF, Kurniawan A, Ramadon D. Microneedle-Mediated Transdermal Delivery of Genetic Materials, Stem Cells, and Secretome: An Update and Progression. Pharmaceutics 2023; 15:2767. [PMID: 38140107 PMCID: PMC10747930 DOI: 10.3390/pharmaceutics15122767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/07/2023] [Accepted: 12/08/2023] [Indexed: 12/24/2023] Open
Abstract
Medical practitioners commonly use oral and parenteral dosage forms to administer drugs to patients. However, these forms have certain drawbacks, particularly concerning patients' comfort and compliance. Transdermal drug delivery presents a promising solution to address these issues. Nevertheless, the stratum corneum, as the outermost skin layer, can impede drug permeation, especially for macromolecules, genetic materials, stem cells, and secretome. Microneedles, a dosage form for transdermal delivery, offer an alternative approach, particularly for biopharmaceutical products. In this review, the authors will examine the latest research on microneedle formulations designed to deliver genetic materials, stem cells, and their derivatives. Numerous studies have explored different types of microneedles and evaluated their ability to deliver these products using preclinical models. Some of these investigations have compared microneedles with conventional dosage forms, demonstrating their significant potential for advancing the development of biotherapeutics in the future.
Collapse
Affiliation(s)
| | - Qonita Kurnia Anjani
- School of Pharmacy, Medical Biology Centre, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, UK; (Q.K.A.); (R.F.D.)
| | - Pietradewi Hartrianti
- School of Life Sciences, Indonesia International Institute of Life Sciences, Jakarta 13210, Indonesia;
| | - Ryan F. Donnelly
- School of Pharmacy, Medical Biology Centre, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, UK; (Q.K.A.); (R.F.D.)
| | - Arief Kurniawan
- Faculty of Pharmacy, Universitas Indonesia, Depok 16424, Indonesia; (A.D.C.N.); (A.K.)
| | - Delly Ramadon
- Faculty of Pharmacy, Universitas Indonesia, Depok 16424, Indonesia; (A.D.C.N.); (A.K.)
| |
Collapse
|
8
|
Dai Y, Nolan J, Madsen E, Fratus M, Lee J, Zhang J, Lim J, Hong S, Alam MA, Linnes JC, Lee H, Lee CH. Wearable Sensor Patch with Hydrogel Microneedles for In Situ Analysis of Interstitial Fluid. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 38041570 DOI: 10.1021/acsami.3c12740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
Continuous real-time monitoring of biomarkers in interstitial fluid is essential for tracking metabolic changes and facilitating the early detection and management of chronic diseases such as diabetes. However, developing minimally invasive sensors for the in situ analysis of interstitial fluid and addressing signal delays remain a challenge. Here, we introduce a wearable sensor patch incorporating hydrogel microneedles for rapid, minimally invasive collection of interstitial fluid from the skin while simultaneously measuring biomarker levels in situ. The sensor patch is stretchable to accommodate the swelling of the hydrogel microneedles upon extracting interstitial fluid and adapts to skin deformation during measurements, ensuring consistent sensing performance in detecting model biomarker concentrations, such as glucose and lactate, in a mouse model. The sensor patch exhibits in vitro sensitivities of 0.024 ± 0.002 μA mM-1 for glucose and 0.0030 ± 0.0004 μA mM-1 for lactate, with corresponding linear ranges of 0.1-3 and 0.1-12 mM, respectively. For in vivo glucose sensing, the sensor patch demonstrates a sensitivity of 0.020 ± 0.001 μA mM-1 and a detection range of 1-8 mM. By integrating a predictive model, the sensor patch can analyze and compensate for signal delays, improving calibration reliability and providing guidance for potential optimization in sensing performance. The sensor patch is expected to serve as a minimally invasive platform for the in situ analysis of multiple biomarkers in interstitial fluid, offering a promising solution for continuous health monitoring and disease management.
Collapse
Affiliation(s)
- Yumin Dai
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - James Nolan
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Emilee Madsen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Marco Fratus
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Junsang Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jinyuan Zhang
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jongcheon Lim
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Seokkyoon Hong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Muhammad A Alam
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Department of Public Health, Purdue University, West Lafayette, Indiana 47907, United States
| | - Hyowon Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Center for Implantable Devices, Purdue University, West Lafayette, Indiana 47907, United States
| | - Chi Hwan Lee
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Center for Implantable Devices, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
9
|
Khan S, Minhas MU. Micro array patch assisted transdermal delivery of high dose, ibuprofen sodium using thermoresponsive sodium alginate/poly (vinylcaprolactam) in situ gels depot. Int J Biol Macromol 2023; 252:126464. [PMID: 37619682 DOI: 10.1016/j.ijbiomac.2023.126464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 08/15/2023] [Accepted: 08/21/2023] [Indexed: 08/26/2023]
Abstract
Current study reports the combined technique of microneedle array patches and thermoresponsive gels. Microneedles array patch mediated insitu skin depots were evaluated for sustain drug delivery using sodium alginate/Poly (vinylcaprolactam) thermoresponsive gels. Their phase transition property from sol-gel state was monitored with AR2000 rheometer. Ibuprofen sodium was loaded in optimized formulations. The non-soluble cross-linked microneedle array patches (MAPs) were prepared from variable biocompatible polymers using silicone micromoulds. The fabricated MAPs were evaluated for mechanical stability, inskin dissolution, insertion forces and moisture contents. The penetration depth of MAPs in neonatal rabbit skin was tracked by optical coherence tomography. The optimized MAPs (GP10000) were used as microporation source in skin owing to their stable nature. Pores formation in skin samples after MAPs treatment was confirmed by optical coherence tomography, dye binding and skin integrity analysis. The invitro permeation of Ibuprofen sodium from formulations was studied using Franz cells across intact skin and MAPs applied skin. It was concluded from the results that Ibuprofen sodium permeation was observed for longer time through MAPs treated skin as compared to intact skin. Confocal study confirmed the diffusion of drug loaded formulations in deeper tissues with higher intensity.
Collapse
Affiliation(s)
- Samiullah Khan
- Centre for Eye and Vision Research, 17W Science Park, Hong Kong.
| | | |
Collapse
|
10
|
Sharma MB, Kap Ö, Abdelmohsen HAM, Ashton MD, Harper GR, Firlak M, Aaltonen JE, Bolland KA, Bragg R, Deeley S, Francis E, Kazi N, Mapley BL, Oikonomou V, Aljohani AD, Cheneler D, Kilic V, Horzum N, Hardy JG. Poly(2-Hydroxyethyl Methacrylate) Hydrogel-Based Microneedles for Metformin Release. GLOBAL CHALLENGES (HOBOKEN, NJ) 2023; 7:2300002. [PMID: 37635699 PMCID: PMC10448145 DOI: 10.1002/gch2.202300002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/21/2023] [Indexed: 08/29/2023]
Abstract
The release of metformin, a drug used in the treatment of cancer and diabetes, from poly(2-hydroxyethyl methacrylate), pHEMA, hydrogel-based microneedle patches is demonstrated in vitro. Tuning the composition of the pHEMA hydrogels enables preparation of robust microneedle patches with mechanical properties such that they would penetrate skin (insertion force of a single microneedle to be ≈40 N). Swelling experiments conducted at 20, 35, and 60 °C show temperature-dependent degrees of swelling and diffusion kinetics. Drug release from the pHEMA hydrogel-based microneedles is fitted to various models (e.g., zero order, first order, second order). Such pHEMA microneedles have potential application for transdermal delivery of metformin for the treatment of aging, cancer, diabetes, etc.
Collapse
Affiliation(s)
- Manoj B. Sharma
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- School of EngineeringLancaster UniversityLancasterLA1 4YWUK
| | - Özlem Kap
- Department of Engineering SciencesIzmir Katip Celebi UniversityIzmir35620Turkey
| | - Hend A. M. Abdelmohsen
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- Department of Pharmaceutics and Industrial PharmacyFaculty of PharmacyAin Shams UniversityAfrican Union Organization StreetAbbassiaCairo11566Egypt
| | - Mark D. Ashton
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
| | - Garry R. Harper
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
| | - Melike Firlak
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- Department of ChemistryGebze Technical UniversityGebze41400Turkey
| | | | | | - Ryan Bragg
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
| | - Sarah Deeley
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
| | - Ella Francis
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
| | - Nahin Kazi
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
| | | | | | - Amal D. Aljohani
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- Department of Chemistry (Female Section)Faculty of ScienceKing Abdulaziz UniversityJeddah‐Rabbigh21589Saudi Arabia
| | - David Cheneler
- School of EngineeringLancaster UniversityLancasterLA1 4YWUK
- Materials Science InstituteLancaster UniversityLancasterLA1 4YBUK
| | - Volkan Kilic
- Department of Electrical and Electronics EngineeringIzmir Katip Celebi UniversityIzmir35620Turkey
| | - Nesrin Horzum
- Department of Engineering SciencesIzmir Katip Celebi UniversityIzmir35620Turkey
| | - John G. Hardy
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- Materials Science InstituteLancaster UniversityLancasterLA1 4YBUK
| |
Collapse
|
11
|
Pervez S, Nasir F, Hidayatullah T, Khattak MA, Alasmari F, Zainab SR, Gohar S, Tahir A, Maryam GE. Transdermal Delivery of Glimepiride: A Novel Approach Using Nanomicelle-Embedded Microneedles. Pharmaceutics 2023; 15:2019. [PMID: 37631233 PMCID: PMC10459310 DOI: 10.3390/pharmaceutics15082019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/23/2023] [Accepted: 07/24/2023] [Indexed: 08/27/2023] Open
Abstract
Glimepiride (GM) is a hydrophobic drug that dissolves slowly and yields inconsistent clinical responses after oral administration. Transdermal drug delivery (TDD) is an appropriate alternative to oral administration. Microneedles (MNs) offer a promising delivery system that penetrates the skin, while polymeric micelles can enhance the solubility; hence, the combination of both results in high drug bioavailability. This study aims to improve glimepiride's solubility, dissolution rate, and bioavailability by incorporating nanomicelles into MNs for TDD. The nanomicelles formulated with 10% Soluplus® (SP) and 40% GM had a mean particle size of 82.6 ± 0.54, PDI of 0.1 ± 0.01, -16.2 ± 0.18 zeta potential, and achieved a 250-fold increase in solubility. The fabricated pyramid shaped GM-dissolving MNs were thermally stable and had no formulation incompatibility, as confirmed by thermal and FTIR analysis. The in vitro dissolution profile revealed that the GM release from nanomicelles and nanomicelle-loaded DMN was concentration-independent following non-Fickian transport mechanism. Improved pharmacokinetic parameters were obtained with dose of 240 µg as compared to 1 mg of GM oral tablet, in healthy human volunteers. The observed Cmax, Tmax and MRT were 1.56 μg/mL ± 0.06, 4 h, and 40.04 h ± 3.37, respectively. The safety profile assessment indicated that microneedles are safe with no adverse effects on skin or health. This study provides an alternative delivery system for the administration of glimepiride, resulting in improved bioavailability, enhanced patient compliance, and reduced dosing frequency.
Collapse
Affiliation(s)
- Sadia Pervez
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Fazli Nasir
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Talaya Hidayatullah
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Muzna Ali Khattak
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Fawaz Alasmari
- Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
| | - Syeda Rabqa Zainab
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Shazma Gohar
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Arbab Tahir
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan; (S.P.); (T.H.); (M.A.K.); (S.R.Z.); (S.G.); (A.T.)
| | - Gul e Maryam
- Department of Pharmacy, Qurtaba University of Science and Information Technology, Peshawar 25000, Pakistan;
| |
Collapse
|
12
|
Hidayatullah T, Nasir F, Khattak MA, Pervez S, Almalki WH, Alasmari F, Maryam GE, Rahman AU, Ali AT. Hybrid Dissolving Microneedle-Mediated Delivery of Ibuprofen: Solubilization, Fabrication, and Characterization. Pharmaceuticals (Basel) 2023; 16:ph16050677. [PMID: 37242460 DOI: 10.3390/ph16050677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/27/2023] [Accepted: 04/27/2023] [Indexed: 05/28/2023] Open
Abstract
Microneedles have recently emerged as a promising platform for delivering therapeutic agents by disrupting the skin, resulting in improved and high drug delivery via this route. Ibuprofen is widely used topically and orally for chronic pain conditions; to avoid untoward gastric effects, topical application is preferred over the oral route. This study aimed to enhance the solubility of the poorly water-soluble ibuprofen using Soluplus (SP) as a solubilizer and to fabricate dissolving microneedle patches of the drug. The fabricated patches were compared with marketed oral and topical formulations of ibuprofen. A 432-fold increase was observed in the solubility of the drug at 8% SP. The FTIR studies revealed that the drug and polymers were compatible. MNs were of uniform morphology and released the drug in a predictable manner. The in vivo analysis on healthy human volunteers revealed a Cmax of 28.7 µg/mL ± 0.5 with a Tmax of 24 h and a MRT of 19.5 h, which was significantly higher than that observed for commercially available topical formulations. The prepared ibuprofen microneedles have higher bioavailability and MRT at a lower dose (165 µg) as compared to tablet and cream doses (200 mg).
Collapse
Affiliation(s)
| | - Fazli Nasir
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan
| | - Muzna Ali Khattak
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan
- Department of Pharmacy, CECOS University of IT and Emerging Sciences, Peshawar 25000, Pakistan
| | - Sadia Pervez
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan
| | - Waleed H Almalki
- Department of Pharmacology and Toxicology, College of Pharmacy, Umm Al-Qura University, Makkah P.O. Box 715, Saudi Arabia
| | - Fawaz Alasmari
- Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Gul E Maryam
- Department of Pharmacy, Qurtaba University of Science and Information Technology, Peshawar 25000, Pakistan
| | - Altaf Ur Rahman
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan
| | - Arbab Tahir Ali
- Department of Pharmacy, University of Peshawar, Peshawar 25000, Pakistan
| |
Collapse
|
13
|
Duarah S, Sharma M, Chen S, Proft TK, Loh J, Wen J. Design, optimization and evaluation of dexamethasone-loaded microneedles for inflammatory disorders. Int J Pharm 2023; 635:122690. [PMID: 36740077 DOI: 10.1016/j.ijpharm.2023.122690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/31/2023] [Accepted: 02/02/2023] [Indexed: 02/05/2023]
Abstract
Dexamethasone (Dex) is a popular and highly potent anti-inflammatory drug, frequently used to treat a wide range of inflammatory disorders. However, the existing oral and parenteral delivery modes have several limitations, including systemic adverse effects and reduced patient compliance. This study aimed to develop a biodegradable microneedle (MN)-based transdermal delivery system capable of sustained, safe and effective delivery of Dex. A Quality by Design (QbD) approach was applied to design the Dex-loaded MN arrays. The formulation variables were optimized using a central composite design (CCD) model, generated with the statistical software package Design- Expert®. The optimized MNs were sharp, with heights ranging between 800 and 900 µm, appropriate for transdermal delivery. The MN arrays did not exhibit any cytotoxic effects on the fibroblast and keratinocyte cells. Moreover, the ex vivo studies confirmed the enhanced efficacy of MN-mediated skin permeation of Dex compared to passive permeation of drug solution. Finally, the in vivo anti-inflammatory efficacy was investigated using the carrageenan-induced rat paw edema model. The efficacy of the MN arrays to inhibit paw edema formation was found to be comparable to that of intravenous Dex injection and significantly greater than topical solution. Cytokine analysis also revealed that application of MN arrays downregulated the expressions of pro-inflammatory cytokines and upregulated the expressions of anti-inflammatory cytokines. Overall, the findings suggest that MN array could be a safe, easy, effective and minimally invasive alternative to the existing means of Dex delivery and could potentially be used for the treatment of inflammatory disorders.
Collapse
Affiliation(s)
- Sanjukta Duarah
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, New Zealand
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, New Zealand
| | - Shuo Chen
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, New Zealand
| | - Thomas K Proft
- Department of Molecular Medicine and Pathology, School of Medical Sciences, The University of Auckland, Auckland, New Zealand; Maurice Wilkins Centre for Biomolecular Discoveries, The University of Auckland, Auckland, New Zealand
| | - Jacelyn Loh
- Department of Molecular Medicine and Pathology, School of Medical Sciences, The University of Auckland, Auckland, New Zealand; Maurice Wilkins Centre for Biomolecular Discoveries, The University of Auckland, Auckland, New Zealand
| | - Jingyuan Wen
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, New Zealand.
| |
Collapse
|
14
|
Alimardani V, Sadat Abolmaali S, Yousefi G, Hossein Nowroozzadeh M, Mohammad Tamaddon A. In-situ nanomicelle forming microneedles of poly NIPAAm-b-poly glutamic acid for trans-scleral delivery of dexamethasone. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.11.072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Chen YJ, Cheng HW, Yen WY, Tsai JH, Yeh CY, Chen CJ, Liu JT, Chen SY, Chang SJ. The Treatment of Keloid Scars via Modulating Heterogeneous Gelatin-Structured Composite Microneedles to Control Transdermal Dual-Drug Release. Polymers (Basel) 2022; 14:4436. [PMID: 36298014 PMCID: PMC9607586 DOI: 10.3390/polym14204436] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/02/2022] [Accepted: 10/15/2022] [Indexed: 07/29/2023] Open
Abstract
Keloid scarring is an abnormal scar disease characterised by excessive proliferation of fibroblasts and over-deposition of collagen during wound healing. Although various treatments for keloid scars have been developed, preventive medicine is believed to be a promising strategy. The skin barrier limits the gentle topical administration of medicaments such as creams and hydrogel dressings, resulting in reduced therapeutic efficacy. In recent years, microneedles (MNs) have been regarded as an appreciable device for topical administration without inducing side effects, and they are painless and do not cause bleeding. In this study, an MN patch with controlled transdermal dual-drug release was developed to achieve combinatory treatment of keloid scars using a heterogeneous gelatin-structured composite MN. Gelatin hydrogel was used as a substrate to load gallic acid (GA) and quercetin-loaded amphiphilic gelatin nanoparticles to fabricate dual-drug heterogeneous composite MNs. The results of the insertion test and mechanical properties of the MNs showed that the heterogeneous composite MN patches could be self-pressed into the stratum corneum and control dual-drug release at different time periods. GA was released at an earlier stage to retard the proliferation of fibroblasts, and quercetin was released at a later stage as a strong antioxidant to erase the generation of reactive oxygen species. Furthermore, real-time quantitative polymerase chain reaction data indicated that the gene expression of fibroblasts (such as Col I and III) was downregulated in the dual-drug system. The above results demonstrate that using heterogeneous composite MNs with the combination of dual-drug pharmacology is beneficial for preventing keloid scar formation.
Collapse
Affiliation(s)
- Yong-Ji Chen
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan
| | - Hung-Wei Cheng
- Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Wan-Yu Yen
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan
| | - Jen-Hao Tsai
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan
| | - Chin-Yi Yeh
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan
| | - Ching-Jung Chen
- Research Center for Materials Science and Opti-Electronic Technology, School of Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jen Tsai Liu
- Research Center for Materials Science and Opti-Electronic Technology, College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - San-Yuan Chen
- Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
- Graduate Institute of Biomedical Science, China Medical University, Taichung 406040, Taiwan
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| | - Shwu-Jen Chang
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan
| |
Collapse
|
16
|
Ju J, Li L, Regmi S, Zhang X, Tang S. Microneedle-Based Glucose Sensor Platform: From Vitro to Wearable Point-of-Care Testing Systems. BIOSENSORS 2022; 12:bios12080606. [PMID: 36005002 PMCID: PMC9405967 DOI: 10.3390/bios12080606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 07/23/2022] [Accepted: 07/27/2022] [Indexed: 11/21/2022]
Abstract
Significant advanced have recently been made in exploiting microneedle-based (MN-based) diabetes devices for minimally invasive wearable biosensors and for continuous glucose monitoring. Within this emerging class of skin-worn MN-based sensors, the ISF can be utilized as a rich biomarker source to diagnose diabetes. While initial work of MN devices focused on ISF extraction, the recent research trend has been oriented toward developing in vivo glucose sensors coupled with optical or electrochemical (EC) instrumentation. This outlook highlights the essential characteristics of the sensing mechanisms, rational design, sensing properties, and applications. Finally, we describe the opinions about the challenge and prospects of optical and EC MN-based device platforms for the fabrication of wearable biosensors and their application potential in the future.
Collapse
Affiliation(s)
- Jian Ju
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou 325001, China
- Oujiang Lab, Wenzhou 325001, China
- Correspondence: (J.J.); (S.T.)
| | - Lin Li
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou 325001, China
- School of Ophthalmology & Optometry, Wenzhou Medical University, Wenzhou 325035, China
| | - Sagar Regmi
- Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Xinyu Zhang
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou 325001, China
| | - Shixing Tang
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou 325001, China
- Department of Epidemiology, School of Public Health, Southern Medical University, Guangzhou 510515, China
- Correspondence: (J.J.); (S.T.)
| |
Collapse
|
17
|
Khan S, Minhas MU, Singh Thakur RR, Aqeel MT. Microneedles Assisted Controlled and Improved Transdermal Delivery of High Molecular Drugs via Insitu Forming Depot Thermoresponsive Poloxamers Gels in Skin Microchannels. Drug Dev Ind Pharm 2022; 48:265-278. [PMID: 35899871 DOI: 10.1080/03639045.2022.2107662] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Skin considered as an attractive route for variety of drug molecules administration. However it proved to be the main physical barrier for drug flux owing to their poor permeability and low bioavailability across stratum corneum layer. In current study novel approach has been used to enhance transdermal delivery via microporation through combination of poloxamers gels and microneedles arrays. The phase transition of poloxamers at various concentrations from sol-gel was evaluated using AR2000 rheometer to confirm microneedles-assisted insitu forming depots. Temperature test confirmed gelation between 32-37 °C. Curcumin was loaded in poloxamer formulations at variable concentrations and its effect showed reduction in critical gelation temperature (CGT) owing to its hydrophobic nature. Microneedles (MNs) arrays (600 µm) prepared from Gantrez S-97, PEG 10000 and Gelatin B using (19 × 19) laser-engineered silicone micromoulds showed high mechanical stability investigated via Texture analyzer. From insitu dissolution profile Gelatin 15% w/w based MNs displayed quicker dissolution rate in comparison to PG10000. VivoSight® OCT scanner and dye tracking confirmed that PG10000 MNs arrays pierced SC layer, infiltrate the epidermis and goes to dermis layer. From invitro permeation, it was concluded that 20% w/w PF127® gel formulations containing (0.1% and 0.3%) curcumin displayed high curcumin permeation for comparatively longer time through microporated skin samples in comparison to non-microporated skin. The curcumin distribution in skin tissues with higher florescence intensity was noted in MNs treated skin samples by confocal microscopy. FTIR confirmed the structure formation of fabricated MNs, while TGA showed dry, brittle and rigid nature of Gelatin MNs.
Collapse
Affiliation(s)
- Samiullah Khan
- Margalla College of Pharmacy, Margalla Institute of Health Sciences, Rawalpindi, Pakistan
| | | | | | - Muhammad Tahir Aqeel
- Margalla College of Pharmacy, Margalla Institute of Health Sciences, Rawalpindi, Pakistan
| |
Collapse
|
18
|
Detamornrat U, McAlister E, Hutton ARJ, Larrañeta E, Donnelly RF. The Role of 3D Printing Technology in Microengineering of Microneedles. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2106392. [PMID: 35362226 DOI: 10.1002/smll.202106392] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/13/2022] [Indexed: 06/14/2023]
Abstract
Microneedles (MNs) are minimally invasive devices, which have gained extensive interest over the past decades in various fields including drug delivery, disease diagnosis, monitoring, and cosmetics. MN geometry and shape are key parameters that dictate performance and therapeutic efficacy, however, traditional fabrication methods, such as molding, may not be able to offer rapid design modifications. In this regard, the fabrication of MNs using 3D printing technology enables the rapid creation of complex MN prototypes with high accuracy and offers customizable MN devices with a desired shape and dimension. Moreover, 3D printing shows great potential in producing advanced transdermal drug delivery systems and medical devices by integrating MNs with a variety of technologies. This review aims to demonstrate the advantages of exploiting 3D printing technology as a new tool to microengineer MNs. Various 3D printing methods are introduced, and representative MNs manufactured by such approaches are highlighted in detail. The development of advanced MN devices is also included. Finally, clinical translation and future perspectives for the development of MNs using 3D printing are discussed.
Collapse
Affiliation(s)
- Usanee Detamornrat
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Emma McAlister
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Aaron R J Hutton
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| |
Collapse
|
19
|
Antonara L, Dallas PP, Rekkas DM. A novel 3D printing enabled method for fast and reliable construction of polymeric microneedles using experimental design. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2021.102888] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Trends in Drug- and Vaccine-based Dissolvable Microneedle Materials and Methods of Fabrication. Eur J Pharm Biopharm 2022; 173:54-72. [DOI: 10.1016/j.ejpb.2022.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 01/24/2022] [Accepted: 02/19/2022] [Indexed: 12/18/2022]
|
21
|
Prabhu A, Jose J, Kumar L, Salwa S, Vijay Kumar M, Nabavi SM. Transdermal Delivery of Curcumin-Loaded Solid Lipid Nanoparticles as Microneedle Patch: an In Vitro and In Vivo Study. AAPS PharmSciTech 2022; 23:49. [PMID: 34988698 DOI: 10.1208/s12249-021-02186-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 11/29/2021] [Indexed: 01/08/2023] Open
Abstract
Curcumin is well known for its neuroprotective effect, and also able to alleviate Parkinsonian features. Clinical application of curcumin is limited due to its low bioavailability. Hence, we hypothesized that the microneedles (MN) containing drug-loaded solid lipid nanoparticles (SLNs) may be able to improve its bioavailability and efficacy. The SLNs were prepared with microemulsion technique using glyceryl monostearate as a lipid and tween 80 as a stabilizer. The particle size, polydispersity index, zeta potential, and entrapment efficiency of prepared SLNs were determined. The optimized formulation was incorporated into microneedle arrays using micromolding technique and fabricated microneedle patch were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, optical microscopy, ex vivo permeation studies, histology studies, and fluorescent microscopy. The fabricated microneedle patch was also evaluated for neuroprotective activity and skin irritation potential. Fourier transform infrared spectroscopy studies of SLNs and microneedles confirmed the chemical compatibility of excipients with curcumin. The developed microneedles were also found to be non-irritant with decreased degree of bradykinesia, high motor coordination, and balance ability. The study provided a theoretical basis for the use of novel microneedle containing curcumin-loaded solid lipid nanoparticles as a useful tool for the treatment of Parkinson's disease.
Collapse
|
22
|
Sharma M, Mittapelly N, Banala VT, Urandur S, Gautam S, Marwaha D, Rai N, Singh N, Gupta A, Mitra K, Mishra PR. Amalgamated Microneedle Array Bearing Ribociclib-Loaded Transfersomes Eradicates Breast Cancer via CD44 Targeting. Biomacromolecules 2022; 23:661-675. [PMID: 34978424 DOI: 10.1021/acs.biomac.1c01076] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
HR+/HER2- metastatic breast cancer (MBC) is one of the most common and life-threatening conditions diagnosed in women. The endocrine therapy using an orally active CDK4/6 inhibitor, ribociclib (RB), is the most intriguing approach for treating HR+/HER2- MBC. However, the repeated three to six cycles of multiple dosing and non-targeted distribution of RB led to severe neutropenia; hepatobiliary, gastrointestinal, and renal toxicities, and QT interval prolongation. Here, a novel organic solvent-free HA-PVA-PVP (hyaluronic acid-polyvinyl alcohol-polyvinyl pyrrolidone) composed of a microneedle (MN) array is formulated to deliver RB, integrated with amphiphilic conjugated polymer (HA-GMS)-anchored ultradeformable transfersomes. This unique MN array efficiently crafts microchannels in the skin, allowing HA-RB-Ts to internalize into the tumor cells through lymphatic and systemic absorption and interact with CD44 both spatially and temporally with an amplification of drug release time up to 6-folds. The pharmacokinetic and tissue distribution studies portray drug concentrations within the therapeutic window as long as 48 h, facilitating thrice-a-week frequency with the lower dose, and rule out severe toxicities, with a significant reduction in 8.3-fold RB concentration in vital organs that ultimately enhances the survival rate. Thus, the novel MN system pursues a unique embeddable feature and offers an effective, self-administrable, biodegradable, and chronic treatment option for patients requiring long-term cancer treatments.
Collapse
Affiliation(s)
- Madhu Sharma
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Rehman NU, Song C, Kim J, Noh I, Rhee YS, Chung HJ. Pharmacokinetic Evaluation of a Novel Donepezil-Loaded Dissolving Microneedle Patch in Rats. Pharmaceutics 2021; 14:pharmaceutics14010005. [PMID: 35056902 PMCID: PMC8778454 DOI: 10.3390/pharmaceutics14010005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 12/13/2021] [Accepted: 12/14/2021] [Indexed: 12/23/2022] Open
Abstract
Research on the development of dissolving microneedles (DMNs) has focused on bolus drug delivery, with little attention on sustained release. Here, we evaluated the sustained release, absorption pattern, and effective drug permeation of a novel donepezil-loaded DMN patch through an in vivo investigation on rats. The applications of DMN patches to the shaved skin of rats for 1 week and 1 h were compared with oral donepezil administration to assess their sustained release capabilities. We used a validated liquid chromatography–tandem mass spectrometry method to quantify donepezil in the plasma. We found that the microneedle arrays effectively delivered donepezil across the skin, with dissolution observed within 1 h of application. Furthermore, skin irritation test showed that the patches produced no irritation response. The DMN arrays also effectively increased drug permeation and demonstrated sustained release and absorption of donepezil from DMN patches. These patches allow extended dosing intervals, reduced gastrointestinal adverse effects, and convenient self-administration to mitigate poor drug compliance, making them beneficial for the treatment of elderly patients with Alzheimer’s disease.
Collapse
|
24
|
Chen J, Liu X, Liu S, He Z, Yu S, Ruan Z, Jin N. Fabrication and characterization of dissolving microneedles for transdermal drug delivery of allopurinol. Drug Dev Ind Pharm 2021; 47:1578-1586. [PMID: 35007175 DOI: 10.1080/03639045.2022.2027959] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Allopurinol (AP) is the first line drug in treating hyperuricemia and gout in clinical by oral drug delivery, which is associated with severe adverse effects and the hepatic first-pass effect. Herein, we first proposed AP encapsulated dissolving microneedles (DMNs) for transdermal drug delivery to realize the sustained drug release and avoid the hepatic first-pass effect, which will help to reduce the adverse effects and improve the bioavailability of AP. DMNs were fabricated by a suspension solution casting method with precisely controlled dose. They had sufficient mechanical strength to penetrate through the skin and resulted in the formation of hundreds of micropores in skin. The results of in vitro and ex vivo release experiments demonstrated that the release profile of DMNs was independent with the dose of AP, and they indeed had much higher drug delivery efficiency (DDE) than the equal amount of AP in solutions. In vivo DDE reached to 38.9% within 1 h, and the drug residual can be served as a drug reservoir for sustained drug release. The result of pharmacodynamic study further confirmed that the sustained release and the anti-hyperuricemia effect of DMNs encapsulating AP were achieved. Moreover, transepidermal water loss significantly increased to 49.50 ± 3.82 g/m2·h after the application of DMNs and returned to normal levels (12.25 ± 0.21 g/m2·h) after 8 h, indicating that the DMNs were well tolerated. These results suggest that transdermal drug delivery of AP by using DMNs is an efficient and safe alternative to currently available routes of administration.
Collapse
Affiliation(s)
- Jianmin Chen
- School of Pharmacy and Medical Technology, Putian University, Putian, China.,Key Laboratory of Pharmaceutical Analysis and Laboratory Medicine (Putian University), Fujian Province University, Putian, China
| | - Xinying Liu
- School of Pharmacy and Medical Technology, Putian University, Putian, China
| | - Siwan Liu
- School of Pharmacy and Medical Technology, Putian University, Putian, China
| | - Zemin He
- School of Pharmacy and Medical Technology, Putian University, Putian, China
| | - Sijin Yu
- School of Pharmacy and Medical Technology, Putian University, Putian, China
| | - Zhipeng Ruan
- School of Pharmacy and Medical Technology, Putian University, Putian, China.,Key Laboratory of Pharmaceutical Analysis and Laboratory Medicine (Putian University), Fujian Province University, Putian, China
| | - Nan Jin
- School of Pharmacy and Medical Technology, Putian University, Putian, China.,Key Laboratory of Pharmaceutical Analysis and Laboratory Medicine (Putian University), Fujian Province University, Putian, China
| |
Collapse
|
25
|
Azizoglu E, Ozer O, Prausnitz MR. Fabrication of pure-drug microneedles for delivery of montelukast sodium. Drug Deliv Transl Res 2021; 12:444-458. [PMID: 34480297 DOI: 10.1007/s13346-021-01047-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/08/2021] [Indexed: 11/28/2022]
Abstract
Dissolving microneedle (MN) patches are usually formulated with a blend of drug and excipients added for mechanical strength and drug stabilization. In this study, we developed MNs made of pure drug to maximize drug loading capacity. MN patches were fabricated for transdermal delivery of montelukast sodium (MS) which is used to treat asthma and allergic rhinitis. We developed three different fabrication methods - solvent casting, melt casting, and solvent washing - and determined that filling molds with MS powder followed by a solvent washing method enabled MS to be loaded selectively to the MNs. Drug localization was confirmed with Raman imaging. MNs were able to penetrate in vitro and ex vivo skin models, and maintained strong mechanical properties during 6 months' storage at 22 °C. MS was also stable and compatible with the formulation used for the patch backing layer after 3 months' storage at 40 °C. MS delivery efficiency into skin was 55%, which enabled delivery of 3.2 mg MS into porcine skin ex vivo, which is in the range of MS doses in human clinical use. We conclude that the solvent washing method can be used to prepare MNs containing pure drug, such as MS at milligram doses in a ~ 1 cm2 MN patch.
Collapse
Affiliation(s)
- Erkan Azizoglu
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, USA.,Faculty of Pharmacy, Department of Pharmaceutical Technology, Ege University, 35040, Bornova, Izmir, Turkey
| | - Ozgen Ozer
- Faculty of Pharmacy, Department of Pharmaceutical Technology, Ege University, 35040, Bornova, Izmir, Turkey
| | - Mark R Prausnitz
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
| |
Collapse
|
26
|
Dalvi M, Kharat P, Thakor P, Bhavana V, Singh SB, Mehra NK. Panorama of dissolving microneedles for transdermal drug delivery. Life Sci 2021; 284:119877. [PMID: 34384832 DOI: 10.1016/j.lfs.2021.119877] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/25/2021] [Accepted: 07/31/2021] [Indexed: 11/16/2022]
Abstract
Recently, microfabrication technology has been developed to increase the permeability of drugs for transdermal delivery. Microneedles are ultra-small needles usually in the micron size range (different dimensions in micron), generate pores, and allow for delivery of local medication in the systemic circulation via skin. The microneedles have been available in dissolving, solid, coated, hollow, and hydrogel-based microneedles. Dissolving microneedles have been fabricated using micro-molding, photo-polymerization, drawing lithography and droplet blowing techniques. Dissolving microneedles could be a valuable option for the delivery of low molecular weight drugs, peptides, enzymes, vaccines and bio-therapeutics. It consists of water-soluble materials including maltose, polyvinyl pyrrolidone, chondroitin sulfate, dextran, hyaluronic acid, and albumin. The microneedles have almost dissolved after patch removal, leaving only blunt stubs behind, which are easily removable. In this review, we summarize the major building blocks, classification, fabrication techniques, characterization, diffusion models and application of microneedles in diverse area. We also reviewed the regulatory aspects, computational studies, patents, clinical data, and market trends of microneedles.
Collapse
Affiliation(s)
- Mayuri Dalvi
- Pharmaceutical Nanotechnology Research Laboratory, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India
| | - Pratik Kharat
- Pharmaceutical Nanotechnology Research Laboratory, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India
| | - Pradip Thakor
- Pharmaceutical Nanotechnology Research Laboratory, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India
| | - Valamla Bhavana
- Pharmaceutical Nanotechnology Research Laboratory, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India
| | - Shashi Bala Singh
- Pharmaceutical Nanotechnology Research Laboratory, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India
| | - Neelesh Kumar Mehra
- Pharmaceutical Nanotechnology Research Laboratory, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research, Hyderabad, Telangana, India.
| |
Collapse
|
27
|
Hydrogel-forming microneedles for rapid and efficient skin deposition of controlled release tip-implants. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 127:112226. [DOI: 10.1016/j.msec.2021.112226] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/25/2021] [Accepted: 05/27/2021] [Indexed: 02/08/2023]
|
28
|
The role of microneedle arrays in drug delivery and patient monitoring to prevent diabetes induced fibrosis. Adv Drug Deliv Rev 2021; 175:113825. [PMID: 34111467 DOI: 10.1016/j.addr.2021.06.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 05/05/2021] [Accepted: 06/04/2021] [Indexed: 02/07/2023]
Abstract
Diabetes affects approximately 450 million adults globally. If not effectively managed, chronic hyperglycaemia causes tissue damage that can develop into fibrosis. Fibrosis leads to end-organ complications, failure of organ systems occurs, which can ultimately cause death. One strategy to tackle end-organ complications is to maintain normoglycaemia. Conventionally, insulin is administered subcutaneously. Whilst effective, this delivery route shows several limitations, including pain. The transdermal route is a favourable alternative. Microneedle (MN) arrays are minimally invasive and painless devices that can enhance transdermal drug delivery. Convincing evidence is provided on MN-mediated insulin delivery. MN arrays can also be used as a diagnostic tool and monitor glucose levels. Furthermore, sophisticated MN array-based systems that integrate glucose monitoring and drug delivery into a single device have been designed. Therefore, MN technology has potential to revolutionise diabetes management. This review describes the current applications of MN technology for diabetes management and how these could prevent diabetes induced fibrosis.
Collapse
|
29
|
Hutton ARJ, Kirkby M, Larrañeta E, Donnelly RF. Designing a unique feedback mechanism for hydrogel-forming microneedle array patches: a concept study. Drug Deliv Transl Res 2021; 12:838-850. [PMID: 34333728 PMCID: PMC8325539 DOI: 10.1007/s13346-021-01033-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/13/2021] [Indexed: 12/02/2022]
Abstract
Although microneedle array patch (MAP) technology is reaching ever closer to regulatory approval, it remains imperative that approaches to further improve patient acceptance are still explored. Addressing this perception, a water-filled reservoir was incorporated into a hydrogel-forming MAP system to provide a novel feedback mechanism. To confirm successful MAP skin insertion, the end user would both hear and feel the rupture of the water-filled reservoir. Interestingly, a 50-µL water-filled reservoir ruptured at 30.27 ± 0.39 N, which has previously been shown as the mean application force for MN insertion in human subjects following appropriate instruction. Importantly, no significant difference in % cumulative permeation of FITC-dextran 10 kDa and fluorescein sodium after 24 h was observed between a 50-µL reservoir and the current method of application that has been successfully used in both in vitro and in vivo studies (p > 0.05). Therefore, as drug delivery was not affected, this proof-of-concept study has shown that a water-filled reservoir feedback mechanism has the potential to serve as a viable tool for consistent MAP skin insertion.
Collapse
Affiliation(s)
- Aaron R J Hutton
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Melissa Kirkby
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK.
| |
Collapse
|
30
|
Zhang L, Guo R, Wang S, Yang X, Ling G, Zhang P. Fabrication, evaluation and applications of dissolving microneedles. Int J Pharm 2021; 604:120749. [PMID: 34051319 DOI: 10.1016/j.ijpharm.2021.120749] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 05/20/2021] [Accepted: 05/24/2021] [Indexed: 01/25/2023]
Abstract
In recent years, transdermal preparations have emerged as one of the most promising modes of administration. In particular, dissolving microneedles have attracted extensive attention because of their painlessness, safety, high delivery efficiency and easily operation for patients. This article mainly reviews the preparation methods, the types of matrix polymer materials, the content of dissolving microneedles performance testing, and the applications of dissolving microneedles. It is expected to lay a solid knowledge foundation for the in-depth study of the dissolving microneedles.
Collapse
Affiliation(s)
- Lijing Zhang
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China
| | - Ranran Guo
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China
| | - Siqi Wang
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China
| | - Xiaotong Yang
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China
| | - Guixia Ling
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China.
| | - Peng Zhang
- Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China.
| |
Collapse
|
31
|
Preparation and characterization of 3D printed PLA microneedle arrays for prolonged transdermal drug delivery of estradiol valerate. Drug Deliv Transl Res 2021; 12:1195-1208. [PMID: 34024015 DOI: 10.1007/s13346-021-01006-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
Biodegradable polymeric microneedle arrays (BPMNAs) could be explored as potential devices for transdermal drug delivery, which can provide a painless and safe drug delivery method. BPMNAs could also provide high drug-loading capacity and prolonged drug delivery once integrated with a drug reservoir. However, the fabrication of MNAs with a drug reservoir is expensive and requires complicated procedures. The present study was conducted to describe the preparation of a reservoir-based BPMNA containing estradiol valerate using polylactic acid (PLA) with the combination of FDM 3D printing and injection volume filling techniques. The tip size of the 3D printed needles decreased to 173 μm utilizing a chemical etching process. The content of estradiol valerate loaded in the 3D printed PLA MNAs was 29.79 ± 0.03 mg, and the release was in a prolonged manner for up to 7 days. The results of mechanical tests revealed that the force needed for the 3D printed PLA MNAs fracture (900 N) was significantly higher than that needed for their skin penetration (4 N). The successful penetration of 3D printed PLA MNAs through the stratum corneum was confirmed via penetration test, methylene blue staining, and histological examination. The results showed that 3D printed PLA MNAs can penetrate into the skin without reaching to the dermal nerves and puncture of blood vessels. In conclusion, in the current study, we explored the practicability of the preparation of drug loaded reservoir-based BPMNAs using the combination of FDM 3D printing and injection volume filling techniques for painless and prolonged transdermal drug delivery.
Collapse
|
32
|
Alimardani V, Abolmaali SS, Yousefi G, Rahiminezhad Z, Abedi M, Tamaddon A, Ahadian S. Microneedle Arrays Combined with Nanomedicine Approaches for Transdermal Delivery of Therapeutics. J Clin Med 2021; 10:E181. [PMID: 33419118 PMCID: PMC7825522 DOI: 10.3390/jcm10020181] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 12/25/2020] [Accepted: 12/28/2020] [Indexed: 12/19/2022] Open
Abstract
Organic and inorganic nanoparticles (NPs) have shown promising outcomes in transdermal drug delivery. NPs can not only enhance the skin penetration of small/biomacromolecule therapeutic agents but can also impart control over drug release or target impaired tissue. Thanks to their unique optical, photothermal, and superparamagnetic features, NPs have been also utilized for the treatment of skin disorders, imaging, and biosensing applications. Despite the widespread transdermal applications of NPs, their delivery across the stratum corneum, which is the main skin barrier, has remained challenging. Microneedle array (MN) technology has recently revealed promising outcomes in the delivery of various formulations, especially NPs to deliver both hydrophilic and hydrophobic therapeutic agents. The present work reviews the advancements in the application of MNs and NPs for an effective transdermal delivery of a wide range of therapeutics in cancer chemotherapy and immunotherapy, photothermal and photodynamic therapy, peptide/protein vaccination, and the gene therapy of various diseases. In addition, this paper provides an overall insight on MNs' challenges and summarizes the recent achievements in clinical trials with future outlooks on the transdermal delivery of a wide range of nanomedicines.
Collapse
Affiliation(s)
- Vahid Alimardani
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran; (V.A.); (Z.R.); (M.A.); (A.T.)
| | - Samira Sadat Abolmaali
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran; (V.A.); (Z.R.); (M.A.); (A.T.)
- Center for Nanotechnology in Drug Delivery, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran;
| | - Gholamhossein Yousefi
- Center for Nanotechnology in Drug Delivery, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran;
| | - Zahra Rahiminezhad
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran; (V.A.); (Z.R.); (M.A.); (A.T.)
| | - Mehdi Abedi
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran; (V.A.); (Z.R.); (M.A.); (A.T.)
| | - Alimohammad Tamaddon
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran; (V.A.); (Z.R.); (M.A.); (A.T.)
- Center for Nanotechnology in Drug Delivery, Shiraz University of Medical Sciences, Shiraz 71348-45794, Iran;
| | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA 90024, USA
| |
Collapse
|
33
|
Permana AD, Nainu F, Moffatt K, Larrañeta E, Donnelly RF. Recent advances in combination of microneedles and nanomedicines for lymphatic targeted drug delivery. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 13:e1690. [PMID: 33401339 DOI: 10.1002/wnan.1690] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 11/17/2020] [Accepted: 11/18/2020] [Indexed: 12/19/2022]
Abstract
Numerous diseases have been reported to affect the lymphatic system. As such, several strategies have been developed to deliver chemotherapeutics to this specific network of tissues and associated organs. Nanotechnology has been exploited as one of the main approaches to improve the lymphatic uptake of drugs. Different nanoparticle approaches utilized for both active and passive targeting of the lymphatic system are discussed here. Specifically, due to the rich abundance of lymphatic capillaries in the dermis, particular attention is given to this route of administration, as intradermal administration could potentially result in higher lymphatic uptake compared to other routes of administration. Recently, progress in microneedle research has attracted particular attention as an alternative for the use of conventional hypodermic injections. The benefits of microneedles, when compared to intradermal injection, are subsequently highlighted. Importantly, microneedles exhibit particular benefit in relation to therapeutic targeting of the lymphatic system, especially when combined with nanoparticles, which are further discussed. However, despite the apparent benefits provided by this combination approach, further comprehensive preclinical and clinical studies are now necessary to realize the potential extent of this dual-delivery platform, further taking into consideration eventual usability and acceptability in the intended patient end-users. This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Nanotechnology Approaches to Biology > Nanoscale Systems in Biology.
Collapse
Affiliation(s)
| | - Firzan Nainu
- Faculty of Pharmacy, Hasanuddin University, Makassar, Indonesia
| | - Kurtis Moffatt
- School of Pharmacy, Queen's University Belfast, Belfast, UK
| | | | | |
Collapse
|
34
|
Pahal S, Badnikar K, Ghate V, Bhutani U, Nayak MM, Subramanyam DN, Vemula PK. Microneedles for Extended Transdermal Therapeutics: A Route to Advanced Healthcare. Eur J Pharm Biopharm 2021; 159:151-169. [PMID: 33388372 DOI: 10.1016/j.ejpb.2020.12.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 12/10/2020] [Accepted: 12/22/2020] [Indexed: 11/17/2022]
Abstract
Sustained release of drugs over a pre-determined period is required to maintain an effective therapeutic dose for variety of drug delivery applications. Transdermal devices such as polymeric microneedle patches and other microneedle-based devices have been utilized for sustained release of their payload. Swift clearing of drugs can be prevented either by designing a slow-degrading polymeric matrix or by providing physiochemical triggers to different microneedle-based devices for on-demand release. These long-acting transdermal devices prevent the burst release of drugs. This review highlights the recent advances of microneedle-based devices for sustained release of vaccines, hormones, and antiretrovirals with their prospective safe clinical translation.
Collapse
Affiliation(s)
- Suman Pahal
- Institute for Stem Cell Science and Regenerative Medicine (inStem), Bangalore, Karnataka 560065, India.
| | - Kedar Badnikar
- Department of Electronics Systems Engineering, Indian Institute of Science, Bangalore, Karnataka 560012, India
| | - Vivek Ghate
- Department of Electronics Systems Engineering, Indian Institute of Science, Bangalore, Karnataka 560012, India
| | - Utkarsh Bhutani
- Institute for Stem Cell Science and Regenerative Medicine (inStem), Bangalore, Karnataka 560065, India
| | - Mangalore Manjunatha Nayak
- Centre for Nano Science and Engineering, Indian Institute of Science, Bangalore, Karnataka 560012, India
| | | | - Praveen Kumar Vemula
- Institute for Stem Cell Science and Regenerative Medicine (inStem), Bangalore, Karnataka 560065, India.
| |
Collapse
|
35
|
Characterization of microneedles and microchannels for enhanced transdermal drug delivery. Ther Deliv 2021; 12:77-103. [DOI: 10.4155/tde-2020-0096] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Microneedle (MN)-based technologies are currently one of the most innovative approaches that are being extensively investigated for transdermal delivery of low molecular weight drugs, biotherapeutic agents and vaccines. Extensive research reports, describing the fabrication and applications of different types of MNs, can be readily found in the literature. Effective characterization tools to evaluate the quality and performance of the MNs as well as for determination of the dimensional and kinetic properties of the microchannels created in the skin, are an essential and critical part of MN-based research. This review paper provides a comprehensive account of all such tools and techniques.
Collapse
|
36
|
Cárcamo-Martínez Á, Mallon B, Anjani QK, Domínguez-Robles J, Utomo E, Vora LK, Tekko IA, Larrañeta E, Donnelly RF. Enhancing intradermal delivery of tofacitinib citrate: Comparison between powder-loaded hollow microneedle arrays and dissolving microneedle arrays. Int J Pharm 2020; 593:120152. [PMID: 33301867 DOI: 10.1016/j.ijpharm.2020.120152] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 11/28/2020] [Accepted: 12/02/2020] [Indexed: 02/06/2023]
Abstract
Autoimmune-mediated inflammatory skin diseases, such as psoriasis, alopecia areata, and vitiligo, have been reported as the 4th leading cause of nonfatal disease burden worldwide. This is mainly related to the poor quality of life experienced by these patients. Although topical and systemic steroids represent the most common treatment, the variability in success rates and side effects often lead to treatment discontinuation. Recent off-label clinical studies using oral Janus Kinase (JAK) inhibitors (e.g., ruxolitinib, tofacitinib, baraticinib) have shown promising results. However, frequent side effects, such as infections and blood clots have been reported. Therefore, the aim of this research was to enhance the intradermal delivery of tofacitinib citrate with MN arrays. Using crosslinked hydrogels containing modifying agents (urea, sorbitol and sodium chloride), hollow MN arrays were fabricated and then loaded with tofacitinib citrate. Their efficiency in intradermal delivery of tofacitinib was compared with dissolving MN arrays and a control (Aqueous cream BP), using neonatal porcine skin. Despite the fact that the hydrogel was only present on the outer surface, hollow MN arrays showed comparable resistance to compression values and insertion capabilities to dissolving MN arrays. Although hollow MN arrays containing NaCl in the formulation led to slightly higher depositions of tofacitinib in epidermis and dermis of neonatal porcine skin when compared to a control cream, dissolving MN arrays showed superiority in terms of tofacitinib deposition in the dermis. Indeed, at 24 h of the study, control cream and dissolving MN arrays delivered 143.98 ug/cm2 and 835 ug/cm2 of drug in the dermis, respectively, confirming the enhanced intradermal drug delivery capacity of MN arrays and their potential for treatment of autoimmune skin diseases.
Collapse
Affiliation(s)
- Álvaro Cárcamo-Martínez
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Brónach Mallon
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Qonita Kurnia Anjani
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Juan Domínguez-Robles
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Emilia Utomo
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Lalit K Vora
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Ismael A Tekko
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK.
| |
Collapse
|
37
|
A new sponge-type hydrogel based on hyaluronic acid and poly(methylvinylether-alt-maleic acid) as a 3D platform for tumor cell growth. Int J Biol Macromol 2020; 165:2528-2540. [PMID: 33098901 DOI: 10.1016/j.ijbiomac.2020.10.095] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 09/29/2020] [Accepted: 10/13/2020] [Indexed: 12/15/2022]
Abstract
A new sponge-type hydrogel was obtained by cross-linking hyaluronic acid (HA) and poly(methylvinylether-alt-maleic acid) P(MVE-alt-MA) through a solvent-free thermal method. The sponge-type hydrogel was characterized and checked as a support for cell growth. The influence of concentration and weight ratio of polymers on the morphology and hydrogel stability was investigated. The total polymers concentration of 3% (w/w) and the weight ratio of 1:1 were optimal for the synthesis of a stable hydrogel (HA3P50) and to promote cell proliferation. The swelling measurements revealed a high-water absorption capacity of the hydrogel in basic medium. Diphenhydramine (DPH), lidocaine (Lid) and propranolol (Prop) were loaded within the hydrogel as a model drugs to investigate the ability of drug transport and release. In vitro studies revealed that HA3P50 hydrogel promoted the adhesion and proliferation of human hepatocellular carcinoma cell line HepG2, providing a good support for 3D cell culture to obtain surrogate tumor scaffold suitable for preclinical anti-cancer drug screening.
Collapse
|
38
|
Stewart S, Domínguez-Robles J, McIlorum VJ, Gonzalez Z, Utomo E, Mancuso E, Lamprou DA, Donnelly RF, Larrañeta E. Poly(caprolactone)-Based Coatings on 3D-Printed Biodegradable Implants: A Novel Strategy to Prolong Delivery of Hydrophilic Drugs. Mol Pharm 2020; 17:3487-3500. [PMID: 32672976 PMCID: PMC7482401 DOI: 10.1021/acs.molpharmaceut.0c00515] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/14/2020] [Accepted: 07/16/2020] [Indexed: 01/18/2023]
Abstract
Implantable devices are versatile and promising drug delivery systems, and their advantages are well established. Of these advantages, long-acting drug delivery is perhaps the most valuable. Hydrophilic compounds are particularly difficult to deliver for prolonged times. This work investigates the use of poly(caprolactone) (PCL)-based implant coatings as a novel strategy to prolong the delivery of hydrophilic compounds from implantable devices that have been prepared by additive manufacturing (AM). Hollow implants were prepared from poly(lactic acid) (PLA) and poly(vinyl alcohol) (PVA) using fused filament fabrication (FFF) AM and subsequently coated in a PCL-based coating. Coatings were prepared by solution-casting mixtures of differing molecular weights of PCL and poly(ethylene glycol) (PEG). Increasing the proportion of low-molecular-weight PCL up to 60% in the formulations decreased the crystallinity by over 20%, melting temperature by over 4 °C, and water contact angle by over 40°, resulting in an increased degradation rate when compared to pure high-molecular-weight PCL. Addition of 30% PEG to the formulation increased the porosity of the formulation by over 50% when compared to an equivalent PCL-only formulation. These implants demonstrated in vitro release rates for hydrophilic model compounds (methylene blue and ibuprofen sodium) ranging from 0.01 to 34.09 mg/day, depending on the drug used. The versatility of the devices produced in this work and the range of release rates achievable show great potential. Implants could be specifically developed in order to match the specific release rate required for a number of drugs for a wide range of conditions.
Collapse
Affiliation(s)
- Sarah
A. Stewart
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| | - Juan Domínguez-Robles
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| | - Victoria J. McIlorum
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| | - Zoilo Gonzalez
- Instituto
De Cerámica y Vidrio, CSIC, c/Kelsen, 5, 28049 Madrid, Spain
| | - Emilia Utomo
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| | - Elena Mancuso
- Nanotechnology
and Integrated Bio-Engineering Centre (NIBEC), Ulster University, Jordanstown BT37 0QB, U.K.
| | - Dimitrios A. Lamprou
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| | - Ryan F. Donnelly
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| | - Eneko Larrañeta
- School
of Pharmacy, Queen’s University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K.
| |
Collapse
|
39
|
Codelivery of hydrophilic and hydrophobic drugs in a microneedle patch for the treatment of skin pigmentation. J IND ENG CHEM 2020. [DOI: 10.1016/j.jiec.2020.04.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
40
|
Cárcamo-Martínez Á, Anjani QK, Permana AD, Cordeiro AS, Larrañeta E, Donnelly RF. Coated polymeric needles for rapid and deep intradermal delivery. INTERNATIONAL JOURNAL OF PHARMACEUTICS-X 2020; 2:100048. [PMID: 32420541 PMCID: PMC7218294 DOI: 10.1016/j.ijpx.2020.100048] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 03/20/2020] [Accepted: 04/18/2020] [Indexed: 11/19/2022]
Abstract
Two groups of single polymeric needles (crosslinked Gantrez®S-97 and poly(ethylene glycol)) of different lengths (2 mm and 4.5 mm) with defined base widths were fabricated and tested in terms of their mechanical strength and insertion abilities using two skin models (Parafilm® and porcine skin). For the shorter needles, application of an axial force (32 N) resulted in a height reduction of approximately 80%. Nonetheless, around 80% of total needle length was successfully inserted in both skin models. Optical coherence tomography showed that base width highly impacted insertion capabilities of the longer needles as only the thicker one (0.922 mm width at base) inserted into porcine skin. Additionally, needles were coated with rhodamine B and inserted into porcine skin. In comparison to a control, penetration depth of the model drug increased 2-fold for short and 4.5-fold for long needles, respectively. Moreover, quantification across skin sections showed that shorter needles delivered 10 μg of the compound in a depth of 1.5–2.0 mm while long needles were capable of delivering 5 μg into even deeper skin layers (2.0–3.0 mm), confirming the potential of coated polymeric needles for rapid and deep intradermal delivery.
Collapse
Affiliation(s)
- Álvaro Cárcamo-Martínez
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Qonita Kurnia Anjani
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Andi Dian Permana
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK.,Department of Pharmaceutics, Faculty of Pharmacy, Hasanuddin University, Makassar, Indonesia
| | - Ana Sara Cordeiro
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| |
Collapse
|
41
|
Cárcamo-Martínez Á, Anjani QK, Permana AD, Cordeiro AS, Larrañeta E, Donnelly RF. WITHDRAWN: Coated polymeric needles for rapid and deep intradermal delivery. Int J Pharm 2020:119355. [PMID: 32325241 DOI: 10.1016/j.ijpharm.2020.119355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 03/20/2020] [Accepted: 04/18/2020] [Indexed: 11/17/2022]
Affiliation(s)
- Álvaro Cárcamo-Martínez
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Qonita Kurnia Anjani
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Andi Dian Permana
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK; Department of Pharmaceutics, Faculty of Pharmacy, Hasanuddin University, Makassar, Indonesia
| | - Ana Sara Cordeiro
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, UK.
| |
Collapse
|
42
|
Hutton ARJ, McCrudden MTC, Larrañeta E, Donnelly RF. Influence of molecular weight on transdermal delivery of model macromolecules using hydrogel-forming microneedles: potential to enhance the administration of novel low molecular weight biotherapeutics. J Mater Chem B 2020; 8:4202-4209. [PMID: 32292995 DOI: 10.1039/d0tb00021c] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
With a view to improve the current monoclonal antibody-based therapies dominating the pharmaceutical market, low molecular weight (MW) protein-based macromolecules, such as recombinant antibody fragments, typically within the range of 10-70 kDa, have been developed. Previously, our group successfully delivered Avastin®, a monoclonal antibody (mAb) across the skin using hydrogel-forming microneedles (MN). However, it is thought that this delivery system can be further enhanced using novel, lower MW biomolecules. To address this perception, in the current study, FITC-dextran of different MWs (10, 70 and 150 kDa) was used to model the transdermal delivery of low MW biotherapeutics and mAbs with MWs of approximately 150 kDa. Conversely, fluorescein sodium was the compound selected to model hydrophilic, low MW drugs. As expected, fluorescein sodium produced the greatest cumulative permeation (637.4 ± 42.69 μg). The amounts of FITC-dextran 10 kDa and 150 kDa which permeated across neonatal porcine skin in vitro were 462.17 ± 65.85 μg and 213.54 ± 15.19 μg after 24 h, respectively. The results collated here suggest that the delivery of emerging novel biotherapeutics, via'super swelling' hydrogel-forming MNs, have the potential to result in greater permeation across human skin, compared to the delivery of mAbs delivered via the same route.
Collapse
Affiliation(s)
- Aaron R J Hutton
- School of Pharmacy, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, UK.
| | | | | | | |
Collapse
|
43
|
Queiroz MLB, Shanmugam S, Santos LNS, Campos CDA, Santos AM, Batista MS, Araújo AADS, Serafini MR. Microneedles as an alternative technology for transdermal drug delivery systems: a patent review. Expert Opin Ther Pat 2020; 30:433-452. [PMID: 32164470 DOI: 10.1080/13543776.2020.1742324] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Introduction: The most conventional drug delivery systems exist with limitations such as drug degradation, toxicity and low bioavailability. Also, hypodermic injections can cause pain, compromising patient compliance. Due to this, transdermal drug delivery systems can minimize several problems associated with conventional drug delivery. The development of microneedle arrays is an approach which allows drug delivery through the skin by improving safety, efficacy, and bioavailability. Hence, several studies have been searching for new ways of treatment using microneedle devices for transdermal drug delivery.Areas covered: All patents were analyzed from European Patent Office and World Intellectual Property Organization databases that reported microneedle arrays using the combined keywords 'microneedle' or 'microneedles' and 'drug delivery systems'. A total of 233 patents were analyzed, out of which 47 selected were microneedle devices for clinical applications.Expert opinion: In past years, there has been a crescent of advances in the development of microneedles as a drug delivery system by researchers and pharmaceutical companies. The authors observed patents related to manufacture of dissolving, hydrogel-forming, solid, hollow, and coated microneedles for ocular and transdermal drug delivery. Finally, the authors noticed patents about new microneedle technologies with potential therapeutic application in several clinical conditions confirmed in clinical tests.
Collapse
Affiliation(s)
| | - Saravanan Shanmugam
- Department of Pharmacy, Federal University of Sergipe, São Cristóvão, Brazil
| | - Lana Naiadhy Silva Santos
- Post-graduate Program in Pharmaceuticals Sciences, Federal University of Sergipe, São Cristóvão, Brazil
| | - Caio de Alcântara Campos
- Post-graduate Program in Pharmaceuticals Sciences, Federal University of Sergipe, São Cristóvão, Brazil
| | | | | | - Adriano Antunes de Souza Araújo
- Post-graduate Program in Pharmaceuticals Sciences, Federal University of Sergipe, São Cristóvão, Brazil.,Department of Pharmacy, Federal University of Sergipe, São Cristóvão, Brazil
| | - Mairim Russo Serafini
- Post-graduate Program in Pharmaceuticals Sciences, Federal University of Sergipe, São Cristóvão, Brazil.,Department of Pharmacy, Federal University of Sergipe, São Cristóvão, Brazil
| |
Collapse
|
44
|
Angkawinitwong U, Courtenay AJ, Rodgers AM, Larrañeta E, McCarthy HO, Brocchini S, Donnelly RF, Williams GR. A Novel Transdermal Protein Delivery Strategy via Electrohydrodynamic Coating of PLGA Microparticles onto Microneedles. ACS APPLIED MATERIALS & INTERFACES 2020; 12:12478-12488. [PMID: 32066234 DOI: 10.1021/acsami.9b22425] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Transdermal delivery of biological therapeutics is emerging as a potent alternative to intravenous or subcutaneous injections. The latter possess major challenges including patient discomfort, the necessity for trained personnel, specialized sharps disposal, and risk of infection. The microneedle (MN) technology circumvents many of the abovementioned challenges, delivering biological materials directly into the skin and allowing sustained release of the active ingredient both in animal models and in humans. This study describes the use of electrohydrodynamic atomization (EHDA) to coat ovalbumin (OVA)-loaded PLGA nanoparticles onto hydrogel-forming MN arrays. The particles showed extended release of OVA over ca. 28 days. Microscopic analysis demonstrated that EHDA could generate a uniform particle coating on the MNs, with 30% coating efficiency. Furthermore, the coated MN array manifested similar mechanical characteristics and insertion properties to the uncoated system, suggesting that the coating should have no detrimental effects on the application of the MNs. The coated MNs resulted in no significant increase in anti-OVA-specific IgG titres in C57BL/6 mice in vivo as compared to the untreated mice (paired t-test, p > 0.05), indicating that the formulations are nonimmunogenic. The approach of using EHDA to coat an MN array thus appears to have potential as a novel noninvasive protein delivery strategy.
Collapse
Affiliation(s)
- Ukrit Angkawinitwong
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, U.K
| | - Aaron J Courtenay
- School of Pharmacy, McClay Research Centre, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K
- School of Pharmacy and Pharmaceutical Sciences, Ulster University, SAAD Building, Cromore Road, Coleraine BT52 1SA, U.K
| | - Aoife M Rodgers
- School of Pharmacy, McClay Research Centre, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K
- Maynooth University Department of Biology, Maynooth University, Maynooth W23 F2K8, Co. Kildare, Ireland
| | - Eneko Larrañeta
- School of Pharmacy, McClay Research Centre, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K
| | - Helen O McCarthy
- School of Pharmacy, McClay Research Centre, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K
| | - Steve Brocchini
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, U.K
| | - Ryan F Donnelly
- School of Pharmacy, McClay Research Centre, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast BT9 7BL, U.K
| | - Gareth R Williams
- UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London WC1N 1AX, U.K
| |
Collapse
|
45
|
Khan S, Minhas MU, Tekko IA, Donnelly RF, Thakur RRS. Evaluation of microneedles-assisted in situ depot forming poloxamer gels for sustained transdermal drug delivery. Drug Deliv Transl Res 2020; 9:764-782. [PMID: 30675693 PMCID: PMC6606675 DOI: 10.1007/s13346-019-00617-2] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
In this study, for the first time, we have reported a sustained transdermal drug delivery from thermoresponsive poloxamer depots formed within the skin micropores following microneedle (MN) application. Firstly, we have investigated the sol–gel phase transition characteristics of poloxamers (PF®127, P108, and P87) at physiological conditions. Rheological measurements were evaluated to confirm the critical gelation temperature (CGT) of the poloxamer formulations with or without fluorescein sodium (FS), as a model drug, at various concentrations. Optimized poloxamer formulations were subjected to in vitro release studies using a vial method. Secondly, polymeric MNs were fabricated using laser-engineered silicone micromolds from various biocompatible polymeric blends of Gantrez S-97, PEG 10000, PEG200, PVP K32, and PVP K90. The MN arrays were characterized for mechanical strength, insertion force determination, in situ dissolution kinetics, moisture content, and penetration depth. The optimized MN arrays with good mechanical strength and non-soluble nature were used to create micropores in the neonatal porcine skin. Microporation in neonatal porcine skin was confirmed by dye-binding study, skin integrity assessment, and histology study. Finally, the in vitro delivery of FS from optimized poloxamer formulations was conducted across non-porated vs microporated skin samples using vertical Franz diffusion cells. Results concluded that permeation of FS was sustained for 96 h across the MN-treated skin samples containing in situ forming depot poloxamer formulations compared to non-microporated skin which sustained the FS delivery for 72 h. Confocal microscopic images confirmed the distribution of higher florescence intensity of FS in skin tissues after permeation study in case of MN-treated skin samples vs intact skin samples.
Collapse
Affiliation(s)
- Samiullah Khan
- Faculty of Pharmacy and Alternative Medicine, The Islamia University of Bahawalpur, Bahawalpur, Punjab, 63100, Pakistan
| | - Muhammad Usman Minhas
- Faculty of Pharmacy and Alternative Medicine, The Islamia University of Bahawalpur, Bahawalpur, Punjab, 63100, Pakistan
| | - Ismaiel A Tekko
- School of Pharmacy, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Raghu Raj Singh Thakur
- School of Pharmacy, Medical Biology Centre, Queen's University Belfast, 97 Lisburn Road, Belfast, BT9 7BL, UK.
| |
Collapse
|
46
|
Cárcamo-Martínez Á, Mallon B, Domínguez-Robles J, Cordeiro AS, Celentano M, Larrañeta E, Bell SEJ, Donnelly RF. Plasmonic photothermal microneedle arrays and single needles for minimally-invasive deep in-skin hyperthermia. J Mater Chem B 2020; 8:5425-5433. [DOI: 10.1039/d0tb00962h] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
We report, for the first time, crosslinked polymeric microneedle (MN) arrays and single needles (2 mm and 4.5 mm length) coated with gold nanorods (GnRs) to induce deep hyperthermia in a 3 mm-thickness skin model upon near infrared (NIR) laser irradiation.
Collapse
Affiliation(s)
| | - Brónach Mallon
- School of Pharmacy
- Queen's University Belfast
- Belfast BT9 7BL
- UK
| | | | | | - Maurizio Celentano
- School of Chemistry and Chemical Engineering
- Queen's University Belfast
- Belfast BT9 5AG
- UK
| | - Eneko Larrañeta
- School of Pharmacy
- Queen's University Belfast
- Belfast BT9 7BL
- UK
| | - Steven E. J. Bell
- School of Chemistry and Chemical Engineering
- Queen's University Belfast
- Belfast BT9 5AG
- UK
| | | |
Collapse
|
47
|
Sabri AH, Kim Y, Marlow M, Scurr DJ, Segal J, Banga AK, Kagan L, Lee JB. Intradermal and transdermal drug delivery using microneedles - Fabrication, performance evaluation and application to lymphatic delivery. Adv Drug Deliv Rev 2020; 153:195-215. [PMID: 31634516 DOI: 10.1016/j.addr.2019.10.004] [Citation(s) in RCA: 80] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 08/26/2019] [Accepted: 10/15/2019] [Indexed: 12/20/2022]
Abstract
The progress in microneedle research is evidenced by the transition from simple 'poke and patch' solid microneedles fabricated from silicon and stainless steel to the development of bioresponsive systems such as hydrogel-forming and dissolving microneedles. In this review, we provide an outline on various microneedle fabrication techniques which are currently employed. As a range of factors, including materials, geometry and design of the microneedles, affect the performance, it is important to understand the relationships between them and the resulting delivery of therapeutics. Accordingly, there is a need for appropriate methodologies and techniques for characterization and evaluation of microneedle performance, which will also be discussed. As the research expands, it has been observed that therapeutics delivered via microneedles has gained expedited access to the lymphatics, which makes them a favorable delivery method for targeting the lymphatic system. Such opportunity is valuable in the area of vaccination and treatment of lymphatic disorders, which is the final focus of the review.
Collapse
|
48
|
Design and Development of Liquid Drug Reservoirs for Microneedle Delivery of Poorly Soluble Drug Molecules. Pharmaceutics 2019; 11:pharmaceutics11110605. [PMID: 31766145 PMCID: PMC6920785 DOI: 10.3390/pharmaceutics11110605] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 11/01/2019] [Accepted: 11/07/2019] [Indexed: 01/31/2023] Open
Abstract
The poor aqueous solubility of existing and emerging drugs is a major issue faced by the pharmaceutical industry. Water-miscible organic solvents, termed co-solvents, can be used to enhance the solubility of poorly soluble substances. Typically, drugs with poor aqueous solubility and Log P > 3 are not amenable to delivery across the skin. This study investigated the use of co-solvents as reservoirs to be used in combination with hydrogel-forming microneedles to enhance the transdermal delivery of hydrophobic compounds, namely Nile red, olanzapine and atorvastatin. A custom-made Franz cell apparatus was fabricated to test the suitability of a liquid drug reservoir in combination with polymeric microneedles. A co-solvency approach to reservoir formulation proved effective, with 83.30% ± 9.38% of Nile red dye, dissolved in 1 mL poly(ethylene glycol) (PEG 400), permeating neonatal porcine skin over 24 h. PEG 400 and propylene glycol were found to be suitable reservoir media for olanzapine and atorvastatin, with approximately 50% of each drug delivered after 24 h. This work provides crucial proof-of-concept evidence that the manipulation of microneedle reservoir properties is an effective method to facilitate microneedle-mediated delivery of hydrophobic compounds.
Collapse
|
49
|
Dissolving Microneedles for Intradermal Vaccination against Shigellosis. Vaccines (Basel) 2019; 7:vaccines7040159. [PMID: 31653077 PMCID: PMC6963400 DOI: 10.3390/vaccines7040159] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 10/22/2019] [Accepted: 10/22/2019] [Indexed: 12/22/2022] Open
Abstract
Intradermal (ID) immunization is of increasing interest due to the easy accessibility and excellent immunogenic properties of the skin. Among ID immunization methods, dissolving microneedles (MNs) have appeared as an alternative to traditional hypodermic immunization, offering many advantages, such as being an easily administered method, with no need for health personnel, painless, and avoiding the use of needles and sharp wastage. In this study, an affordable and easy-to-produce MNs method was developed based on aqueous blends of 30% w/w poly (methyl vinyl ether-co-maleic anhydride). As an antigen model, a subunit vaccine candidate based on outer membrane vesicles from Shigella flexneri was used. Both unloaded and antigen-loaded MNs were synthetized and characterized. The MNs were successfully validated in an in vitro Parafilm M® skin model and in a pig skin ex vivo model. Biodistribution studies were performed in BALB/c mice using 99mTcO4− radiolabeled samples. Results indicated that the vesicle vaccine was successfully released from the MNs and targeted gastrointestinal tract after 6 h post-administration. In vivo immunization and protection studies were performed in BALB/c mice. Mice were intradermally immunized through ear skin with one single dose of 200 μg antigenic complex, eliciting the production of specific systemic IgG and mucosal IgA. Moreover, MNs were able to protect mice from an experimental infection with 1×106 CFU/mouse of S. flexneri four weeks after immunization. This work demonstrates for the first time the potential of outer membrane vesicle-loaded dissolving MNs for ID vaccination against enteropathogens like Shigella.
Collapse
|
50
|
|