Tang HT, Nörz D, Grunwald M, Giersch K, Pfefferle S, Fischer N, Aepfelbacher M, Rohde H, Lütgehetmann M. Analytical and clinical validation of a novel, laboratory-developed, modular multiplex-PCR panel for fully automated high-throughput detection of 16 respiratory viruses. J Clin Virol 2024; 173:105693. [PMID: 38820916 DOI: 10.1016/j.jcv.2024.105693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 05/10/2024] [Accepted: 05/13/2024] [Indexed: 06/02/2024]
Abstract
BACKGROUND Viral respiratory Infections pose a health risk, especially to vulnerable patient populations. Effective testing programs can detect and differentiate these infections at an early stage, which is particularly important for high-risk clinical departments. The objective of this study was to develop and validate a multiplex PCR-panel for 16 different respiratory viruses on a fully-automated high-throughput platform. METHODS Three multiplex-PCR assays were designed to run on the cobas5800/6800/8800 systems, consolidating 16 viral targets: RESP1: SARS-CoV-2, influenza-A/B, RSV; RESP2: hMPV, hBoV, hAdV, rhino-/ENV; RESP3: HPIV-1-4, hCoV-229E, hCoV-NL63, hCoV-OC43, hCoV-HKU1. Analytic performance was evaluated using digital-PCR based standards and international reference material. Clinical performance was determined by comparing results from clinical samples with reference assays. RESULTS Analytical sensitivity (i.e. lower limit of detection (LoD), 95 % probability of detection) was determined as follows: SARS-CoV-2: 29.3 IU/ml, influenza-A: 179.9 cp/ml, influenza-B: 333.9 cp/ml and RSV: 283.1 cp/ml. LoDs of other pathogens ranged between 9.4 cp/ml (hCoV-NL63) and 21,419 cp/ml (HPIV-2). Linearity was verified over 4-7 log-steps with pooled standard differentials (SD) ranging between 0.18-0.70ct. Inter-/intra-run variability (precision) was assessed for all targets over 3 days. SDs ranged between 0.13-0.74ct. Positive agreement in clinical samples was 99.4 % and 95 % for SARS-CoV-2 and influenza-A respectively. Other targets were in the 80-100 % range. Negative agreement varied between 96.3-100 %. DISCUSSION Lab-developed tests are a key factor for effective clinical diagnostics. The multiplex panel presented in this study demonstrated high performance and provides an easily scalable high-throughput solution for respiratory virus testing, e.g. for testing in high-risk patient populations.
Collapse
Affiliation(s)
- Hui Ting Tang
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Dominik Nörz
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Moritz Grunwald
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Katja Giersch
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Susanne Pfefferle
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Nicole Fischer
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Martin Aepfelbacher
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Holger Rohde
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany
| | - Marc Lütgehetmann
- University Medical Center Hamburg-Eppendorf, Institute of Medical Microbiology, Virology and Hygiene, Hamburg, Germany.
| |
Collapse
|
2
|
Self-collected gargle fluids and nasopharyngeal swabs as a strategy for molecular diagnostics of respiratory viruses. JOURNAL OF CLINICAL VIROLOGY PLUS 2022. [DOI: 10.1016/j.jcvp.2022.100116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
3
|
Li M, Yin F, Song L, Mao X, Li F, Fan C, Zuo X, Xia Q. Nucleic Acid Tests for Clinical Translation. Chem Rev 2021; 121:10469-10558. [PMID: 34254782 DOI: 10.1021/acs.chemrev.1c00241] [Citation(s) in RCA: 78] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Nucleic acids, including deoxyribonucleic acid (DNA) and ribonucleic acid (RNA), are natural biopolymers composed of nucleotides that store, transmit, and express genetic information. Overexpressed or underexpressed as well as mutated nucleic acids have been implicated in many diseases. Therefore, nucleic acid tests (NATs) are extremely important. Inspired by intracellular DNA replication and RNA transcription, in vitro NATs have been extensively developed to improve the detection specificity, sensitivity, and simplicity. The principles of NATs can be in general classified into three categories: nucleic acid hybridization, thermal-cycle or isothermal amplification, and signal amplification. Driven by pressing needs in clinical diagnosis and prevention of infectious diseases, NATs have evolved to be a rapidly advancing field. During the past ten years, an explosive increase of research interest in both basic research and clinical translation has been witnessed. In this review, we aim to provide comprehensive coverage of the progress to analyze nucleic acids, use nucleic acids as recognition probes, construct detection devices based on nucleic acids, and utilize nucleic acids in clinical diagnosis and other important fields. We also discuss the new frontiers in the field and the challenges to be addressed.
Collapse
Affiliation(s)
- Min Li
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Fangfei Yin
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Lu Song
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.,Division of Physical Biology, CAS Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
| | - Xiuhai Mao
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Fan Li
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Chunhai Fan
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Xiaolei Zuo
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.,School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Qiang Xia
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| |
Collapse
|
4
|
Bekhof J, Wessels M, Ten Velde E, Hoekstra M, Langenhorst V, Bruijnesteijn L, Brand PLP, Ruijs GJHM. Room Sharing in Hospitalized Children With Bronchiolitis and the Occurrence of Hospital-Acquired Infections: A Prospective Cohort Study. Hosp Pediatr 2020; 9:415-422. [PMID: 31138604 DOI: 10.1542/hpeds.2018-0222] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVES To determine the prevalence and severity of hospital-acquired infections (HAIs) in children hospitalized for bronchiolitis when patients share a room, irrespective of the causative virus. METHODS A prospective cohort study during 4 winter seasons (2012-2016) was conducted in a Dutch general pediatric ward including otherwise healthy children <2 years of age hospitalized for bronchiolitis. Patients shared a 1-to-4-bed hospital room irrespective of virological diagnosis. The main outcome measures were HAIs assessed through multiplex polymerase chain reaction and disease severity. RESULTS HAIs occurred in 28 of 218 included patients (12.8%), most frequently with rhinovirus (17 of 28; 60.7%). In 3 (10.7%) of 28 HAIs, the same virus was identified in roommates. Only 1 patient became cross-infected with respiratory syncytial virus, although this patient never shared a room with a patient infected with respiratory syncytial virus. HAI was not associated with more severe disease. The median length of hospitalization was 3.5 days (interquartile range [IQR] 1-6) compared with 3 days (IQR 2-6; P = .86); the number of PICU admissions was 0% versus 5.3% (P = .21); the median days of oxygen supplementation was 2.5 (IQR 1-4) versus 2 (IQR 1-4; P = .58); the median days of tube feeding was 2 (IQR 0-5) versus 2 (interquartile range: 0-5; P = .77); and the readmission rate was 0% versus 5.8% (P = .19) in patients with and without HAI, respectively. CONCLUSIONS HAIs among patients with bronchiolitis are common but not associated with more severe disease. Room sharing with appropriate hygiene does not play a relevant role in the transmission of viruses between patients with bronchiolitis, regardless of the viruses involved. On the basis of these findings, we suggest that room sharing of patients with bronchiolitis is safe.
Collapse
Affiliation(s)
| | | | | | | | | | - Lesla Bruijnesteijn
- Laboratory for Clinical Microbiology and Infectious Diseases, Isala Clinics, Zwolle, Netherlands; and
| | - Paul L P Brand
- Isala Women and Children's Hospital and.,Graduate School of Medicine, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Gijs J H M Ruijs
- Laboratory for Clinical Microbiology and Infectious Diseases, Isala Clinics, Zwolle, Netherlands; and
| |
Collapse
|
5
|
Molecular Diagnosis of Pneumonia Using Multiplex Real-Time PCR Assay RespiFinder® SMART 22 FAST in a Group of Moroccan Infants. Adv Virol 2020; 2020:6212643. [PMID: 32148499 PMCID: PMC7049438 DOI: 10.1155/2020/6212643] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2019] [Accepted: 01/25/2020] [Indexed: 01/18/2023] Open
Abstract
Background In Morocco, pediatric pneumonia remains a serious public health problem, as it constitutes the first cause of mortality due to infectious diseases. The etiological diagnosis of acute respiratory tract infections is difficult. Therefore, it is necessary to use Multiplex real-time polymerase chain reaction assay tests in a routine setting for exact and fast identification. Objectives In this paper, we present the clinical results of pediatric pneumonia and describe their etiology by using molecular diagnosis. Study design: Tracheal secretion was collected from infants presenting respiratory distress isolated or associated with systemic signs, attending the unit of Neonatology between December 1, 2016, and Mai 31, 2018. Samples were tested with the multiplex RespiFinder® SMART 22 FAST which potentially detects 18 viruses and 4 bacteria. Results Of the 86 infants considered in this study (mean age 31 ± 19 days) suspected of acute respiratory tract infections, 71 (83%) were positive for one or multiple viruses or/and bacteria. The majority of acute respiratory tract infections had a viral origin (95%): respiratory syncytial viruses (A and B) (49%), rhinovirus (21%), coronaviruses 229E (11%), humain metapneumovirus (5%), influenza A (3%), influenza H1N1 (1%), adenovirus (2%), and parainfluenza virus type 4 (2%). Among our patients, 6% had Mycoplasma pneumoniae. Coinfections were not associated with severe respiratory symptoms. Conclusion The clinical spectrum of respiratory infections is complex and often nonspecific. Thus, the early and fast detection of related causative agents is crucial. The use of multiplex real time polymerase chain reaction may help choose an accurate treatment, reduce the overall use of unnecessary antibiotics, preserve intestinal flora, and decrease nosocomial infection by reducing the length of hospitalization.
Collapse
|
6
|
LIU GS, LI H, ZHAO SC, LU RJ, NIU PH, TAN WJ. Viral and Bacterial Etiology of Acute Febrile Respiratory Syndrome among Patients in Qinghai, China. BIOMEDICAL AND ENVIRONMENTAL SCIENCES : BES 2019; 32:438-445. [PMID: 31262389 PMCID: PMC7135780 DOI: 10.3967/bes2019.058] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Accepted: 03/25/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVE This study was conducted to investigate the viral and bacterial etiology and epidemiology of patients with acute febrile respiratory syndrome (AFRS) in Qinghai using a commercial routine multiplex-ligation-nucleic acid amplification test (NAT)-based assay. METHODS A total of 445 nasopharyngeal swabs specimens from patients with AFRS were analyzed using the RespiFinderSmart22kit (PathoFinder BV, Netherlands) and the LightCycler 480 real-time PCR system. RESULTS Among the 225 (225/445, 51%) positive specimens, 329 positive pathogens were detected, including 298 (90.58%) viruses and 31 (9%) bacteria. The most commonly detected pathogens were influenza virus (IFV; 37.39%; 123/329), adenovirus (AdV; 17.02%; 56/329), human coronaviruses (HCoVs; 10.94%; 36/329), rhinovirus/enterovirus (RV/EV; 10.03%; 33/329), parainfluenza viruses (PIVs; 8.51%; 28/329), and Mycoplasma pneumoniae (M. pneu; 8.51%; 28/329), respectively. Among the co-infected cases (17.53%; 78/445), IFV/AdV and IFV/M. pneu were the most common co-infections. Most of the respiratory viruses were detected in summer and fall. CONCLUSION In our study, IFV-A was the most common respiratory pathogen among 22 detected pathogens, followed by AdV, HCoV, RV/EV, PIV, and M. pneu. Bacteria appeared less frequently than viruses, and co-infection was the most common phenomenon among viral pathogens. Pathogens were distributed among different age groups and respiratory viruses were generally active in July, September, and November. Enhanced surveillance and early detection can be useful in the diagnosis, treatment, and prevention of AFRS, as well as for guiding the development of appropriate public health strategies.
Collapse
Affiliation(s)
- Gao Shan LIU
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China
| | - Hong LI
- Center for Disease Control and Prevention of Qinghai Province, Xining 810007, Qinghai, China
| | - Sheng Cang ZHAO
- Center for Disease Control and Prevention of Qinghai Province, Xining 810007, Qinghai, China
| | - Rou Jian LU
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China
| | - Pei Hua NIU
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China
| | - Wen Jie TAN
- NHC Key Laboratory of Biosafety, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China
| |
Collapse
|
7
|
Radko S, Ian Stuart J, Zahariadis G. Evaluation of three commercial multiplex assays for the detection of respiratory viral infections. J Virol Methods 2017. [PMID: 28633962 PMCID: PMC7119489 DOI: 10.1016/j.jviromet.2017.06.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Comparison of Dual Priming Oligonucleotide vs. Liquid Bead Suspension Array vs. Tagged Oligo Cleavage Extension chemistry for the detection of respiratory viruses from adult and pediatric populations. Co-infections are detected frequently with these multiplex assays, especially in children, that it may impact current policies to cohort patients based on the result of a single virus. All 3 commercial assays are based on different chemistries and are statistically non-inferior to each other in terms of sensitivity and specificity, both on prospective and retrospective samples. Choice of assay by a clinical lab depends on volumes, cost, and work-flow considerations.
Background Timely identification of respiratory virus infection is essential to mitigate inappropriate antibiotic use and to implement appropriate treatment and/or infection control procedures. As such, multiplexed PCR assays have become standard in many virology laboratories. Objectives To compare the Seeplex RV15 (test of record) with two newer generation multiplex assays, the Anyplex II RV16 and the xTAG respiratory virus panels. Study design Two hundred and three retrospective and 36 prospective respiratory samples were tested by all three assays. Samples were deemed to be positive if they tested positive for a virus by at least two of the three respective assays. Negative samples also had to test negative by at least two of the three assays. Inconclusive samples were those that showed band signal intensity between 0 and 100 on the RV15, but had not been previously tested on the RV16 or xTAG. Results and conclusions Overall sensitivity and specificity of all three assays were similar (∼85% and 100%, respectively). Given each assay can identify multiple different viruses, the targets reported by one assay did not always agree with each target from another assay. Partial discordant rates were 47% and 21% for positive and negative samples, respectively. These higher than expected partial discordant rates may be due to primer or chemistry differences amongst the three multiplex assays.
Collapse
Affiliation(s)
- Sandi Radko
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
| | - J Ian Stuart
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
| | - George Zahariadis
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.
| |
Collapse
|
8
|
Comparison of ePlex Respiratory Pathogen Panel with Laboratory-Developed Real-Time PCR Assays for Detection of Respiratory Pathogens. J Clin Microbiol 2017; 55:1938-1945. [PMID: 28404682 PMCID: PMC5442551 DOI: 10.1128/jcm.00221-17] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Accepted: 04/04/2017] [Indexed: 11/27/2022] Open
Abstract
Infections of the respiratory tract can be caused by a diversity of pathogens, both viral and bacterial. Rapid microbiological diagnosis ensures appropriate antimicrobial therapy as well as effective implementation of isolation precautions. The ePlex respiratory pathogen panel (RP panel) is a novel molecular biology-based assay, developed by GenMark Diagnostics, Inc. (Carlsbad, CA), to be performed within a single cartridge for the diagnosis of 25 respiratory pathogens (viral and bacterial). The objective of this study was to compare the performance of the RP panel with those of laboratory-developed real-time PCR assays, using a variety of previously collected clinical respiratory specimens. A total of 343 clinical specimens as well as 29 external quality assessment (EQA) specimens and 2 different Middle East respiratory syndrome coronavirus isolates have been assessed in this study. The RP panel showed an agreement of 97.4% with the real-time PCR assay regarding 464 pathogens found in the clinical specimens. All pathogens present in clinical samples and EQA samples with a threshold cycle (CT) value of <30 were detected correctly using the RP panel. The RP panel detected 17 additional pathogens, 7 of which could be confirmed by discrepant testing. In conclusion, this study shows excellent performance of the RP panel in comparison to real-time PCR assays for the detection of respiratory pathogens. The ePlex system provided a large amount of useful diagnostic data within a short time frame, with minimal hands-on time, and can therefore potentially be used for rapid diagnostic sample-to-answer testing, in either a laboratory or a decentralized setting.
Collapse
|
9
|
Fagbo SF, Garbati MA, Hasan R, AlShahrani D, Al-Shehri M, AlFawaz T, Hakawi A, Wani TA, Skakni L. Acute viral respiratory infections among children in MERS-endemic Riyadh, Saudi Arabia, 2012-2013. J Med Virol 2016; 89:195-201. [PMID: 27430485 PMCID: PMC7166860 DOI: 10.1002/jmv.24632] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/14/2016] [Indexed: 11/10/2022]
Abstract
The emergence of the Middle East Respiratory Syndrome (MERS) in Saudi Arabia has intensified focus on Acute Respiratory Infections [ARIs]. This study sought to identify respiratory viruses (RVs) associated with ARIs in children presenting at a tertiary hospital. Children (aged ≤13) presenting with ARI between January 2012 and December 2013 tested for 15 RVs using the SeeplexR RV15 kit were retrospectively included. Epidemiological data was retrieved from patient records. Of the 2235 children tested, 61.5% were ≤1 year with a male: female ratio of 3:2. Viruses were detected in 1364 (61.02%) children, 233 (10.4%) having dual infections: these viruses include respiratory syncytial virus (RSV) (24%), human rhinovirus (hRV) (19.7%), adenovirus (5.7%), influenza virus (5.3%), and parainfluenzavirus-3 (4.6%). Children, aged 9-11 months, were most infected (60.9%). Lower respiratory tract infections (55.4%) were significantly more than upper respiratory tract infection (45.3%) (P < 0.001). Seasonal variation of RV was directly and inversely proportional to relative humidity and temperature, respectively, for non MERS coronaviruses (NL63, 229E, and OC43). The study confirms community-acquired RV associated with ARI in children and suggests modulating roles for abiotic factors in RV epidemiology. However, community-based studies are needed to elucidate how these factors locally influence RV epidemiology. J. Med. Virol. 89:195-201, 2017. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
| | - Musa A Garbati
- King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | - Rami Hasan
- King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | | | | | - Tariq AlFawaz
- King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | - Ahmed Hakawi
- King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| | | | - Leila Skakni
- King Fahad Medical City, Riyadh, Kingdom of Saudi Arabia
| |
Collapse
|
10
|
Using Nucleic Acid Amplification Techniques in a Syndrome-Oriented Approach: Detection of Respiratory Agents. Mol Microbiol 2016. [DOI: 10.1128/9781555819071.ch25] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
11
|
Leonard DG. Respiratory Infections. MOLECULAR PATHOLOGY IN CLINICAL PRACTICE 2016. [PMCID: PMC7123443 DOI: 10.1007/978-3-319-19674-9_52] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
The majority of respiratory tract infections (RTIs) are community acquired and are the single most common cause of physician office visits and among the most common causes of hospitalizations. The morbidity and mortality associated with RTIs are significant and the financial and social burden high due to lost time at work and school. The scope of clinical symptoms can significantly overlap among the respiratory pathogens, and the severity of disease can vary depending on patient age, underlying disease, and immune status, thereby leading to inaccurate presumptions about disease etiology. The rapid and accurate diagnosis of the causative agent of RTIs improves patient care, reduces morbidity and mortality, promotes effective hospital bed utilization and antibiotic stewardship, and reduces length of stay. This chapter focuses on the clinical utility, advantages, and disadvantages of viral and bacterial tests cleared by the Food and Drug Administration (FDA), and new promising technologies for the detection of bacterial agents of pneumonia currently in development or in US FDA clinical trials are briefly reviewed.
Collapse
Affiliation(s)
- Debra G.B. Leonard
- Pathology and Laboratory Medicine, University of Vermont College of Medicine and University of Vermont Medical Center, Burlington, Vermont USA
| |
Collapse
|
12
|
García‐Arroyo L, Prim N, Martí N, Roig MC, Navarro F, Rabella N. Benefits and drawbacks of molecular techniques for diagnosis of viral respiratory infections. Experience with two multiplex PCR assays. J Med Virol 2016; 88:45-50. [PMID: 26100363 PMCID: PMC7166422 DOI: 10.1002/jmv.24298] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/11/2015] [Indexed: 11/08/2022]
Abstract
Molecular techniques have represented a major step forward in the diagnosis of viral respiratory infections. They are considered highly sensitive and specific compared to conventional techniques. In this study two nucleic acid amplification tests (NAATs) were compared to conventional methods (immunofluorescence and viral culture). The aim of this work was to discuss the clinical interpretation of the results obtained by NAATs on the basis of the two-decade experience of our group and the literature. Eighty nasopharyngeal aspirates were collected from children under six years attended for acute respiratory illness at the pediatric emergency room of a third level Hospital. Both NAATs tested (Seeplex(®) and Clart(®)) showed an overall higher performance regarding sensitivity (76% and 90%, respectively). Compared to Seeplex(®), the Clart(®) system tripled the number of multiple detections (8 by Seeplex(®) vs. 25 by Clart(®)). In some specimens both NAATs detected different viruses. Given these discrepancies and the fact that detection of viral nucleic acids is not necessarily related to the current clinical syndrome, the interpretation of molecular results may not always be so straightforward. The pros and cons of NAATs should always be taken into account when giving a result.
Collapse
Affiliation(s)
| | - Núria Prim
- Servei de Microbiologia, Hospital de la Santa Creu i Sant PauBarcelonaSpain
| | - Neus Martí
- Servei de Microbiologia, Hospital de la Santa Creu i Sant PauBarcelonaSpain
| | - Maria Carme Roig
- Servei de Microbiologia, Hospital de la Santa Creu i Sant PauBarcelonaSpain
| | - Ferran Navarro
- Servei de Microbiologia, Hospital de la Santa Creu i Sant PauBarcelonaSpain
- Departament de Genètica i de MicrobiologiaUniversitat Autònoma de BarcelonaBarcelonaSpain
| | - Núria Rabella
- Servei de Microbiologia, Hospital de la Santa Creu i Sant PauBarcelonaSpain
- Departament de Genètica i de MicrobiologiaUniversitat Autònoma de BarcelonaBarcelonaSpain
| |
Collapse
|
13
|
Salez N, Vabret A, Leruez-Ville M, Andreoletti L, Carrat F, Renois F, de Lamballerie X. Evaluation of Four Commercial Multiplex Molecular Tests for the Diagnosis of Acute Respiratory Infections. PLoS One 2015; 10:e0130378. [PMID: 26107509 PMCID: PMC4481272 DOI: 10.1371/journal.pone.0130378] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2014] [Accepted: 05/20/2015] [Indexed: 11/19/2022] Open
Abstract
Acute Respiratory Infections (ARIs) are responsible for considerable morbidity and mortality worldwide. Documentation of respiratory specimens can help for an appropriate clinical management with a significant effect on the disease progress in patient, the antimicrobial therapy used and the risk of secondary spread of infection. Here, we compared the performances of four commercial multiplex kits used in French University Hospital diagnostic microbiology laboratories for the detection of ARI pathogens (i.e., the xTAG Respiratory Viral Panel Fast, RespiFinder SMART 22, CLART PneumoVir and Fast Track Diagnostics Respiratory Pathogen 33 kits). We used a standardised nucleic acids extraction protocol and a comprehensive comparative approach that mixed reference to well established real-time PCR detection techniques and analysis of convergent positive results. We tested 166 respiratory clinical samples and identified a global high degree of correlation for at least three of the techniques (xTAG, RespiFinder and FTD33). For these techniques, the highest Youden's index (YI), positive predictive (PPV) and specificity (Sp) values were observed for Core tests (e.g., influenza A [YI:0.86-1.00; PPV:78.95-100.00; Sp:97.32-100.00] & B [YI:0.44-1.00; PPV:100.00; Sp:100.00], hRSV [YI:0.50-0.99; PPV:85.71-100.00; Sp:99.38-100.00], hMPV [YI:0.71-1.00; PPV:83.33-100.00; Sp:99.37-100.00], EV/hRV [YI:0.62-0.82; PPV:93.33-100.00; Sp:94.48-100.00], AdV [YI:1.00; PPV:100.00; Sp:100.00] and hBoV [YI:0.20-0.80; PPV:57.14-100.00; Sp:98.14-100.00]). The present study completed an overview of the multiplex techniques available for the diagnosis of acute respiratory infections.
Collapse
Affiliation(s)
- Nicolas Salez
- Aix Marseille Université, IRD French Institute of Research for Development, EHESP French School of Public Health, EPV UMR_D 190 "Emergence des Pathologies Virales", Marseille, France
- * E-mail:
| | - Astrid Vabret
- Laboratory of Human and Molecular Virology, IFR146 ICORE, University Hospital, Caen, France
| | - Marianne Leruez-Ville
- Virology Laboratory, Hôpital Necker Enfants malades, APHP, Université Paris Descartes, Sorbonne Paris Cité-EA 36–20, Paris, France
| | - Laurent Andreoletti
- Unité de Virologie Médicale et Moléculaire, Centre Hospitalier Universitaire, and IFR 53/EA-4303 (DAT/PPCIDH), Faculté de Médecine, Reims, France
| | - Fabrice Carrat
- UMR-S 707 INSERM, Pierre et Marie Curie University, Paris, France
- Public Assistance Hospital of Paris, Department of Internal Medicine, Hôpital Saint Antoine, Unité de Santé Publique, Paris, France
| | - Fanny Renois
- Unité de Virologie Médicale et Moléculaire, Centre Hospitalier Universitaire, and IFR 53/EA-4303 (DAT/PPCIDH), Faculté de Médecine, Reims, France
| | - Xavier de Lamballerie
- Aix Marseille Université, IRD French Institute of Research for Development, EHESP French School of Public Health, EPV UMR_D 190 "Emergence des Pathologies Virales", Marseille, France
- IHU Institute hospitalo-universitaire Méditerranée Infection, APHM Public Hospitals of Marseille, Marseille, France
| |
Collapse
|
14
|
Simon A, Manoha C, Müller A, Schildgen O. Human Metapneumovirus and Its Role in Childhood Respiratory Infections. CURRENT PEDIATRICS REPORTS 2014. [DOI: 10.1007/s40124-014-0048-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Thissen JB, McLoughlin K, Gardner S, Gu P, Mabery S, Slezak T, Jaing C. Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray. J Virol Methods 2014; 201:73-8. [DOI: 10.1016/j.jviromet.2014.01.024] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2013] [Revised: 01/14/2014] [Accepted: 01/21/2014] [Indexed: 11/26/2022]
|
16
|
Berning L, Aberle SW, Simon B, Luger C, Apfalter P, Machherndl-Spandl S, Kerschner H. Evaluation of a multiplex ligation-dependent probe amplification assay for the detection of respiratory pathogens in oncological patients. J Clin Virol 2014; 60:141-6. [PMID: 24684925 PMCID: PMC7106480 DOI: 10.1016/j.jcv.2014.02.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2013] [Revised: 02/18/2014] [Accepted: 02/26/2014] [Indexed: 12/21/2022]
Abstract
Background Respiratory tract infections are widespread and may cause significant morbidity and mortality in immunosuppressed populations such as oncological patients. Objectives The RealAccurate Respiratory RT PCR Kit covering 14 respiratory viruses was compared to the RespiFinder Smart22, a broad-spectrum multiplex ligation-dependent probe amplification (MLPA) test, targeting 22 viral and bacterial respiratory pathogens. Study design After verification of its analytical performance, the clinical performance of the RespiFinder Smart22 was evaluated by re-analysis of 96 respiratory samples from oncological patients. Additionally, the time to result (TTR) of both methods was compared. Results The analytical performance of the RespiFinder Smart22 fulfilled all previously specified criteria. Concordant results in both assays were achieved in 74.0% of all clinical specimens and in 91.2% when only positive results were taken into account. The RespiFinder Smart22 yielded additional results in a total of 22 (22.9% of 96) samples due to higher test sensitivity and a broader, highly multiplexed spectrum of pathogens. The TTR of a typical routine test consisting of three samples were 206 and 356 min for the RealAccurate Respiratory RT PCR Kit and the RespiFinder Smart22, respectively. However, hands-on time was reduced by 59.0% applying the MLPA method. Conclusions In our hands, the RespiFinder Smart22 showed excellent analytical performance while hands-on time was halved in comparison to the RT PCR method. Regarding the clinical evaluation, the MLPA method provided additional results in 22.9% (22/96) of specimens due to its comprehensive format, higher test sensitivity and the capability to detect 22 pathogens compared to 14 with the RealAccurate Respiratory RT PCR Kit.
Collapse
Affiliation(s)
- Lucia Berning
- analyse BioLab, Elisabethinen Hospital Linz, Eisenhandstrasse 4-6, 4020 Linz, Austria
| | - Stephan W Aberle
- Department of Virology, Medical University of Vienna, Kinderspitalgasse 15, 1095 Vienna, Austria
| | - Benedikt Simon
- Department of Virology, Medical University of Vienna, Kinderspitalgasse 15, 1095 Vienna, Austria
| | - Christoph Luger
- analyse BioLab, Elisabethinen Hospital Linz, Eisenhandstrasse 4-6, 4020 Linz, Austria
| | - Petra Apfalter
- analyse BioLab, Elisabethinen Hospital Linz, Eisenhandstrasse 4-6, 4020 Linz, Austria
| | - Sigrid Machherndl-Spandl
- 1st Internal Department - Hematology with Stem Cell Transplantation, Hemostaseology and Medical Oncology, Elisabethinen Hospital Linz, Fadingerstrasse 1, 4020 Linz, Austria
| | - Heidrun Kerschner
- analyse BioLab, Elisabethinen Hospital Linz, Eisenhandstrasse 4-6, 4020 Linz, Austria.
| |
Collapse
|
17
|
Cho CH, Lee CK, Nam MH, Yoon SY, Lim CS, Cho Y, Kim YK. Evaluation of the AdvanSure™ real-time RT-PCR compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses. Diagn Microbiol Infect Dis 2014; 79:14-8. [PMID: 24582583 PMCID: PMC7132754 DOI: 10.1016/j.diagmicrobio.2014.01.016] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 01/19/2014] [Accepted: 01/23/2014] [Indexed: 11/29/2022]
Abstract
Recently, AdvanSure™ kit based on multiplex real-time PCR was developed for simultaneous detection of 14 respiratory viruses (RVs). We compared the performance of AdvanSure with those of Seeplex® RV 15 ACE and culture by determining their sensitivities and specificities against a composite reference standard. Four hundred thirty-seven respiratory samples were tested by modified shell vial culture method, RV 15 ACE, and AdvanSure. One hundred fourteen samples (26.2%) out of 437 samples were positive by culture, while additional 91 (20.8%) were positive by AdvanSure or RV15. One hundred twelve of 114 culture-positive samples were positive by AdvanSure except 2 samples (1 adenovirus, 1 respiratory syncytial virus [RSV]). Overall, the sensitivities of culture, RV15, and AdvanSure were 74.5%, 89.8%, and 95.1%, respectively. Sensitivities of culture, RV15, and AdvanSure for each virus tested were as follows: 91/100/96% for influenza A, 60/0/100% for influenza B, 63/95/97% for RSV, 69/81/89% for adenovirus, and 87/93/93% for parainfluenza virus. For viruses not covered by culture, sensitivities of RV15 and AdvanSure were as follows: 77/88% for rhinovirus, 100/100% for coronavirus OC43, 40/100% for coronavirus 229E/NL63, 13/100% for metapneumovirus, and 44/100% for bocavirus. The overall specificities of culture, RV15, and AdvanSure were 100/98.9/99.5%, respectively. Of 45 coinfected specimens, AdvanSure detected 41 specimens (91.1%) as coinfected, while RV15 detected 27 specimens (60.0%) as coinfected. AdvanSure assay demonstrated exquisite performance for the detection of RVs and will be a valuable tool for the management of RV infection.
Collapse
Affiliation(s)
- Chi Hyun Cho
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea
| | - Chang Kyu Lee
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea.
| | - Myung-Hyun Nam
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea
| | - Soo-Young Yoon
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea
| | - Chae Seung Lim
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea
| | - Yunjung Cho
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea
| | - Young Kee Kim
- Department of laboratory medicine, College of Medicine, Korea University, Seoul, Republic of Korea
| |
Collapse
|
18
|
Pillet S, Lardeux M, Dina J, Grattard F, Verhoeven P, Le Goff J, Vabret A, Pozzetto B. Comparative evaluation of six commercialized multiplex PCR kits for the diagnosis of respiratory infections. PLoS One 2013; 8:e72174. [PMID: 24058410 PMCID: PMC3751960 DOI: 10.1371/journal.pone.0072174] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2012] [Accepted: 07/12/2013] [Indexed: 11/26/2022] Open
Abstract
The molecular diagnosis of respiratory infection can be performed using different commercial multiplex-based PCR kits whose performances have been previously compared individually to those of conventional techniques. This study compared the practicability and the diagnostic performances of six CE-marked kits available in 2011 on the French market, including 2 detecting viruses and atypical bacteria (from Pathofinder and Seegene companies) and 4 detecting only viruses (from Abbott, Genomica, Qiagen and Seegene companies). The respective sensitivity, specificity, accuracy and agreement of each multiplex technique were calculated by comparison to commercial duplex PCR tests (Argene/bioMérieux) used as gold standard. Eighty-eight respiratory specimens with no pathogen (n = 11), single infections (n = 33) or co-infections (n = 44) were selected to cover 9 viruses or groups of viruses and 3 atypical bacteria. All samples were extracted using the NUCLISENS® easyMAG™ instrument (bioMérieux). The overall sensitivity ranged from 56.25% to 91.67% for viruses and was below 50% with both tests for bacteria. The overall specificity was excellent (>94% for all pathogens). For each tested kit, the overall agreement with the reference test was strong for viruses (kappa test >0.60) and moderate for bacteria. After the extraction step, the hands-on time varied from 50 min to 2h30 and the complete results were available in 2h30 to 9 h. The spectrum of tested agents and the technology used to reveal the PCR products as well as the laboratory organization are determinant for the selection of a kit.
Collapse
Affiliation(s)
- Sylvie Pillet
- Laboratory of Bacteriology and Virology, University Hospital of Saint-Etienne, Saint-Etienne, France
| | - Marina Lardeux
- Laboratory of Bacteriology and Virology, University Hospital of Saint-Etienne, Saint-Etienne, France
| | - Julia Dina
- Laboratory of Virology, University Hospital of Caen, Caen, France
| | - Florence Grattard
- Laboratory of Bacteriology and Virology, University Hospital of Saint-Etienne, Saint-Etienne, France
| | - Paul Verhoeven
- Laboratory of Bacteriology and Virology, University Hospital of Saint-Etienne, Saint-Etienne, France
| | - Jérôme Le Goff
- Université Paris Diderot, Sorbonne Paris Cité, Microbiology Department, Saint-Louis Hospital, APHP, Paris, France
| | - Astrid Vabret
- Laboratory of Virology, University Hospital of Caen, Caen, France
| | - Bruno Pozzetto
- Laboratory of Bacteriology and Virology, University Hospital of Saint-Etienne, Saint-Etienne, France
- * E-mail:
| |
Collapse
|
19
|
A two-tube multiplex reverse transcription PCR assay for simultaneous detection of sixteen human respiratory virus types/subtypes. BIOMED RESEARCH INTERNATIONAL 2013; 2013:327620. [PMID: 23984344 PMCID: PMC3747601 DOI: 10.1155/2013/327620] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2013] [Accepted: 06/25/2013] [Indexed: 11/17/2022]
Abstract
There is a need for the development of a rapid and sensitive diagnosis of respiratory viral pathogens. With an intended application in provincial Centers for Diseases Control and Prevention, in this study, we present a two-tube multiplex RT-PCR assay (two-tube assay) using automatic electrophoresis to simultaneously detect sixteen common respiratory viruses. The specificity and the sensitivity of the assay were tested. The assay could detect 20-200 copies per reaction when each viral type was assayed individually, 2000 copies with 9 premixed viral targets in the multiplexed assay in tube 1, and 200 copies with 8 premixed templates in tube 2. A total of 247 specimens were used to evaluate the two-tube assay, and the results were compared with those obtained from the Luminex xTAG RVP Fast assay. The discordant results were confirmed by sequencing or by the Seeplex RV15 ACE detection kit. There were no false positives, but six false negatives occurred with the two-tube assay. In conclusion, the two-tube assay is demonstrated to have great potential for routine surveillance of respiratory virus infection in China.
Collapse
|
20
|
Rheem I, Park J, Kim TH, Kim JW. Evaluation of a multiplex real-time PCR assay for the detection of respiratory viruses in clinical specimens. Ann Lab Med 2012; 32:399-406. [PMID: 23130338 PMCID: PMC3486933 DOI: 10.3343/alm.2012.32.6.399] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2012] [Revised: 04/30/2012] [Accepted: 08/17/2012] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND In this study, we evaluated the analytical performance and clinical potential of a one-step multiplex real-time PCR assay for the simultaneous detection of 14 types of respiratory viruses using the AdvanSure RV real-time PCR Kit (LG Life Sciences, Korea). METHODS Three hundred and twenty clinical specimens were tested with the AdvanSure RV real-time PCR Kit and conventional multiplex reverse transcription (RT)-PCR assay. The assay results were analyzed and the one-step AdvanSure RV real-time PCR Kit was compared with the conventional multiplex RT-PCR assay with respect to the sensitivity and specificity of the detection of respiratory viruses. RESULTS The limit of detection (LOD) was 1.31 plaque-forming units (PFU)/mL for human rhinoviruses (hRVs), 4.93 PFU/mL for human coronavirus HCoV-229E/NL63, 2.67 PFU/mL for human coronavirus HCoV-OC43, 18.20 PFU/mL for parainfluenza virus 1 (PIV)-1, 24.57 PFU/mL for PIV-2, 1.73 PFU/mL for PIV-3, 1.79 PFU/mL for influenza virus group (Flu) A, 59.51 PFU/mL for FluB, 5.46 PFU/mL for human respiratory syncytial virus (hRSV)-A, 17.23 PFU/mL for hRSV-B, 9.99 PFU/mL for human adenovirus (ADVs). The cross-reactivity test for this assay against 23 types of non-respiratory viruses showed negative results for all viruses tested. The agreement between the one-step AdvanSure multiplex real-time PCR assay and the conventional multiplex RT-PCR assay was 98%. CONCLUSIONS The one-step AdvanSure RV multiplex real-time PCR assay is a simple assay with high potential for specific, rapid and sensitive laboratory diagnosis of respiratory viruses compared to conventional multiplex RT-PCR.
Collapse
Affiliation(s)
- Insoo Rheem
- Department of Laboratory Medicine, Dankook University College of Medicine, Cheonan, Korea
| | | | | | | |
Collapse
|
21
|
Abstract
It has been 10 years since human metapneumovirus (HMPV) was identified as a causative agent of respiratory illness in humans. Since then, numerous studies have contributed to a substantial body of knowledge on many aspects of HMPV. This review summarizes our current knowledge on HMPV, HMPV disease pathogenesis, and disease intervention strategies and identifies a number of areas with key questions to be addressed in the future.
Collapse
|
22
|
Kanashiro TM, Vilas Boas LS, Thomaz AM, Tozetto-Mendoza TR, Setsuko M, Machado CM. Identification of respiratory virus in infants with congenital heart disease by comparison of different methods. Rev Inst Med Trop Sao Paulo 2012; 53:241-6. [PMID: 22012448 DOI: 10.1590/s0036-46652011000500001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2011] [Accepted: 08/22/2011] [Indexed: 11/22/2022] Open
Abstract
Respiratory virus infections are the main cause of infant hospitalization and are potentially severe in children with congenital heart disease (CHD). Rapid and sensitive diagnosis is very important to early introduction of antiviral treatment and implementation of precautions to control transmission, reducing the risk of nosocomial infections. In the present study we compare different techniques in the diagnosis of respiratory viruses in CHD infants. Thirty-nine samples of nasopharyngeal aspirate were obtained from CHD infants with symptoms of respiratory infection. The Multiplex PCR (Seeplex® RV 12 ACE Detection) driven to the detection of 12 respiratory viruses was compared with the direct immunofluorescence assay (DFA) and PCR, both targeting seven respiratory viruses. The positivity found by DFA, Multiplex and PCR was 33.3%, 51.3% and 48.7%, respectively. Kappa index comparing DFA and Multiplex, DFA and PCR and PCR and Multiplex PCR was 0.542, 0.483 and 0.539, respectively. The concordance between techniques was considered moderate. Both Multiplex PCR (p = 0.001) and PCR (p = 0.002) detected significantly more respiratory virus than DFA. As the performance of the tests may vary, the combination of two or more techniques may increase diagnostic sensitivity favoring the diagnosis of co-infections, early introduction of antiviral therapy and implementation of appropriate measures.
Collapse
Affiliation(s)
- Tatiana Mitiko Kanashiro
- Laboratório de Virologia, Instituto de Medicina Tropical de São Paulo, Universidade de São Paulo, São Paulo, SP, Brazil
| | | | | | | | | | | |
Collapse
|
23
|
Abstract
INTRODUCTION Influenza virus infections cause significant morbidity, and the unique ability of these viruses to undergo antigenic drift and shift means that it is critical for current laboratory assays to keep pace with these changes for accurate diagnosis. New subtypes have the potential to evolve into pandemics hence accurate virus subtyping is also essential. AREAS COVERED In this article, the authors review the current techniques available to detect influenza virus. EXPERT OPINION The biggest gains in improving on influenza diagnostics may lie in reappraising our current approach and optimizing all existing steps in influenza detection: pre-analytical, analytical, post-analytical. In addition, we must foster close collaboration between governments, surveillance networks and frontline diagnostic laboratories, and utilize advances in information technology to facilitate these interactions and to disseminate crucial information.
Collapse
Affiliation(s)
- Matthew C Gray
- Department of Microbiology and Infectious Diseases, Sydney South West Pathology Service -Liverpool , Locked Bag 7090, Liverpool BC, NSW, 1871 , Australia +0061 2 9828 5124 ; +0061 2 9828 5129 ;
| | | | | |
Collapse
|
24
|
Comparison of the FilmArray Respiratory Panel and Prodesse real-time PCR assays for detection of respiratory pathogens. J Clin Microbiol 2011; 49:4083-8. [PMID: 21998418 DOI: 10.1128/jcm.05010-11] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
We compared the diagnostic performance and overall respiratory pathogen detection rate of the premarket version of the FilmArray Respiratory Panel (RP) multiplex PCR assay (Idaho Technology, Inc., Salt Lake City, UT) with those of the Food and Drug Administration (FDA)-cleared Prodesse ProFlu+, ProFAST+, ProParaflu+, Pro hMPV+, and ProAdeno+ real-time PCR assays (Gen-Probe, San Diego, CA). The assays were performed on a panel of 192 nasopharyngeal-secretion specimens collected from 81 children under 1 year of age with upper respiratory tract symptoms. To resolve discordant results and confirm pathogens detected only by the larger FilmArray panel, we performed laboratory-developed real-time PCR assays. Among viruses detectable by both commercial assays (adenovirus, human metapneumovirus, influenza A virus, influenza B virus, parainfluenza viruses 1 to 3, and respiratory syncytial virus), the FilmArray and Prodesse assays showed good overall agreement (181/192 [94.3%]; kappa = 0.87; 95% CI, 0.79 to 0.94). FilmArray RP detected more parainfluenza viruses 1 and 3 than ProParaflu+ (18 versus 13) while ProAdeno+ detected more adenoviruses (11 versus 6), but these differences were not statistically significant. Additionally, FilmArray RP detected 138 pathogens (confirmed as true positives) not included in the Prodesse assays (rhinovirus [RV]/enterovirus [EV], 118; bocavirus, 8; coronavirus, 7; parainfluenza virus 4, 4; Mycoplasma pneumoniae, 1). FilmArray RP was cleared by the FDA following the completion of this study. The FDA-cleared version includes the following targets: adenovirus, coronaviruses HKU1 and NL63, human metapneumovirus (hMPV), influenza A virus (to type level only), influenza A H1 seasonal virus, influenza A H3 seasonal virus, influenza A virus H1-2009, influenza B virus, parainfluenza viruses 1 to 4, respiratory syncytial virus (RSV), and RV/EV (no differentiation). The larger panel in the FilmArray RP assay allowed the detection of additional respiratory pathogens compared to the Prodesse assays. In this population of young children with upper respiratory tract infection, RV/EV accounted for the majority of the additional pathogens detected by FilmArray RP.
Collapse
|
25
|
Raymaekers M, de Rijke B, Pauli I, Van den Abeele AM, Cartuyvels R. Timely diagnosis of respiratory tract infections: evaluation of the performance of the Respifinder assay compared to the xTAG respiratory viral panel assay. J Clin Virol 2011; 52:314-6. [PMID: 21925937 PMCID: PMC7185546 DOI: 10.1016/j.jcv.2011.08.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2011] [Revised: 08/10/2011] [Accepted: 08/16/2011] [Indexed: 11/30/2022]
Abstract
Background Respiratory tract infections are the most common cause of hospitalization in infants and young children and are typically caused by viral or, less commonly, bacterial pathogens. Existing non-molecular diagnostic methods have several drawbacks such as limited sensitivity, long turn-a-round time and limited number of pathogens that can be detected. Objectives Nucleic acid amplification methods can increase sensitivity and enable the initiation of appropriate interventions without delay. Broad-spectrum detection and identification circumvent the use of individual diagnostic DNA or RNA based assays. At present, several commercial assays are available for broad-spectrum detection. Study design We compared the performance of the xTAG Respiratory Viral Panel (RVP) (Luminex Molecular Diagnostics, Toronto, Canada) with that of the Respifinder (Pathofinder, Maastricht, Netherlands) for 9 external quality assurance (EQA) panels (QCMD, Scotland) consisting of a total of 106 EQA samples. Results Both the RVP and the Respifinder assay have an excellent specificity. Sensitivity was 33% and 78% for the RVP and the Respifinder assay, respectively. For both assays, sensitivity was low for weak positive samples. Discussion The results of our study seem to indicate a better sensitivity for the Respifinder. Analysis of patient samples is necessary to evaluate the clinical performance.
Collapse
Affiliation(s)
- M Raymaekers
- Clinical Laboratory, Jessa Hospital, Site Virga Jesse, Stadsomvaart 11, B-3500 Hasselt, Belgium.
| | | | | | | | | |
Collapse
|