1
|
Gürkan M, Kumbuloglu O, Şahan MH, Narin M, Kandaş H, Arman Y, Yildiz H, Pekedis M. Biomechanics of the implant-supported full arch fixed complete denture manufactured by milling and injection techniques: An experimental and FEA study. J Prosthodont 2025. [PMID: 40263893 DOI: 10.1111/jopr.14058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Accepted: 04/01/2025] [Indexed: 04/24/2025] Open
Abstract
PURPOSE This study aims to characterize the mechanical properties of implant-supported full arch fixed complete dentures manufactured by milling and injection techniques. MATERIALS AND METHODS Twenty-two samples with milling and injection manufacturing techniques were fabricated. Twenty-two titanium samples were manufactured to be used as the control group. Additionally, eight PEEK samples from both the injection and milling groups were manufactured and tested using a uniaxial tensile test, and the obtained results were used as input data for finite element analysis (FEA). All-on-four PEEK hybrid prostheses supported with 2 implants on the mandible were used for the simulations. The FEA computations were performed for a bilateral 150 N force applied in both vertical and oblique directions. RESULTS A significant difference was observed between the injection and milled PEEK groups in terms of modulus of elasticity (Injection PEEK group: 3.1 ± 0.6 GPa, Milling PEEK: 4.6 ± 0.9 GPa) and flexural rigidity (Injection PEEK group: 28.0 ± 5.8 kNmm2, Milling PEEK: 41.2 ± 8.4 kNmm2) (p < 0.05), while no significant differences were observed between the injection and milled PEEK groups in terms of other parameters (p > 0.05). The finite element results showed that the highest stresses were observed in the Injection PEEK group, while the lowest were observed in the Milling Titanium group. Both injection and milled PEEK frameworks exceeded the yield stress limit during vertical and oblique loading. CONCLUSION It was concluded that the forces implemented on rigid framework material such as titanium were better distributed to the implants supporting the all-on-four prosthesis.
Collapse
Affiliation(s)
- Mustafa Gürkan
- Advanced Prosthodontics, Medicadent, Private Clinic, Ataşehir, Istanbul, Turkey
| | - Ovul Kumbuloglu
- School of Dentistry, Department of Prosthodontics, Ege University, Izmir, Turkey
| | - Makbule Heval Şahan
- School of Dentistry, Department of Prosthodontics, Ege University, Izmir, Turkey
| | - Mert Narin
- Faculty of Engineering, Department of Mechanical Engineering, Ege University, Izmir, Turkey
| | - Halis Kandaş
- Faculty of Engineering, Department of Mechanical Engineering, Dokuz Eylul University, Izmir, Turkey
| | - Yusuf Arman
- Faculty of Engineering, Department of Mechanical Engineering, Dokuz Eylul University, Izmir, Turkey
| | - Hasan Yildiz
- Faculty of Engineering, Department of Mechanical Engineering, Ege University, Izmir, Turkey
| | - Mahmut Pekedis
- Faculty of Engineering, Department of Mechanical Engineering, Ege University, Izmir, Turkey
| |
Collapse
|
2
|
Alnafaiy SM, Labban N, Albaijan R, AlKahtani RN, Al-Aali KA, Abozaed HW, Alturki NY, Alenezi JE. Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers. Polymers (Basel) 2025; 17:554. [PMID: 40076048 PMCID: PMC11901903 DOI: 10.3390/polym17050554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2025] [Revised: 02/16/2025] [Accepted: 02/19/2025] [Indexed: 03/14/2025] Open
Abstract
This study assessed the shear bond strength (SBS) and failure modes of lithium disilicate ceramic veneering material to different high-performance polymers. Thirty-six square specimens measuring 7 × 7 × 2 ± 0.05 mm were prepared from pure polyetheretherketone (PEEK), Bio-high performance PEEK (BioHPP) and Trilor discs. Polymer specimens were air-borne abraded utilizing aluminum oxide particles, cleaned, and a bonding agent was applied (visio. link). The veneering LDC material (3 × 2 mm) was milled, hydrofluoric acid etched (9.5%) and primed (Clearfil ceramic). The LDC was bonded to the polymer specimens using dual-cured resin cement (Panavia V5) and light polymerized. The bonded specimens were subjected to 5000 cycles of physiological aging by thermocycling, and the SBS test was performed in a universal testing machine at 0.5 mm/min cross-head speed. The debonded specimens were analyzed to determine the primary bond failure sites (adhesive, mixed or cohesive). Data analysis was performed using one-way ANOVA and a post hoc Tukey test (α ≤ 0.05). The BioHPP material demonstrated the highest SBS values (23.94 ± 1.43 MPa), and the Trilor group recorded the lowest SBS values (17.09 ± 1.07 MPa). The PEEK group showed a mean SBS of 21.21 ± 1.51 MPa. The SBS comparison showed significant variations across all material groups (p < 0.001). Regarding failure modes, adhesive failure was observed in 40% of BioHPP and PEEK specimens and 90% of Trilor specimens. The cohesive failure occurred in 50% of PEEK and 30% of BioHPP specimens, while the Trilor specimens showed no cohesive failure. Mixed failures were reported in 30% of BioHPP and 10% of PEEK and Trilor specimens. The BioHPP material demonstrated high SBS followed by PEEK and Trilor. The SBS between the tested materials was statistically significant. However, the SBS of the tested implant framework materials was above the limit stipulated by the ISO 10477 standard (5 MPa) and the clinically acceptable range of 10-12 MPa.
Collapse
Affiliation(s)
- Sarah M. Alnafaiy
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (R.N.A.); (K.A.A.-A.)
| | - Nawaf Labban
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
| | - Refal Albaijan
- Department of Prosthodontics, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (R.A.); (H.W.A.)
| | - Rawan N. AlKahtani
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (R.N.A.); (K.A.A.-A.)
| | - Khulud A. Al-Aali
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (R.N.A.); (K.A.A.-A.)
| | - Heba Wageh Abozaed
- Department of Prosthodontics, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (R.A.); (H.W.A.)
- Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt
| | - Nada Y. Alturki
- Dental Intern, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (N.Y.A.); (J.E.A.)
| | - Jomana E. Alenezi
- Dental Intern, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (N.Y.A.); (J.E.A.)
| |
Collapse
|
3
|
Kharboush MGA, Othman HI, Aldamaty MF, Alameldin AML. Fracture resistance and mode of failure of modified Polyether-ether-ketone versus lithium disilicate endocrowns. BMC Oral Health 2025; 25:40. [PMID: 39773219 PMCID: PMC11707867 DOI: 10.1186/s12903-024-05232-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Accepted: 11/19/2024] [Indexed: 01/11/2025] Open
Abstract
PURPOSE The current study aimed to compare modified Polyether-ether-ketone's fracture resistance and failure mode versus lithium disilicate glass-ceramic endocrowns. MATERIALS AND METHODS A total of 16 butt-joint endocrown specimens on mandibular second molar teeth were fabricated and divided into two equivalent groups; Pressable modified Polyether-ether-ketone (PEEK) (BioHPP®) and Pressable lithium disilicate glass ceramic (IPS e.max® Press). A computer-aided design/computer-aided manufacturing system was used to digitally create and milled wax patterns. Final restorations were cemented each to its corresponding prepared tooth. Thermomechanical cycling loading representing one year of clinical service was done in a chewing simulator. Fracture resistance was evaluated utilizing a universal testing machine. The failure mode was evaluated by inspecting fractured surfaces using a Stereomicroscope and further examined by a Scanning Electron Microscope (SEM) amongst both groups. RESULTS A statistically significant variation in fracture resistance was recorded with a mean load of (2762.96 ± 216.15 N) for modified PEEK and (2175.91 ± 267.72 N) for lithium disilicate glass-ceramic endocrowns. CONCLUSION Modified PEEK endocrowns have higher fracture resistance than lithium disilicate glass-ceramic endocrowns. Moreover, the likeliness of catastrophic fracture in molars receiving endodontic treatment restored by modified PEEK is less than teeth restored with lithium disilicate glass ceramics.
Collapse
Affiliation(s)
- Mohamed G A Kharboush
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt.
| | - Hesham I Othman
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt
| | - Mohamed F Aldamaty
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt.
- Department of Restorative and Aesthetic Dentistry, College of Dentistry, Almaaqal University, Basrah, Iraq.
| | - Ahmed M L Alameldin
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, 11651, Egypt
| |
Collapse
|
4
|
Sinha N, Thompson GA, Drago C, An H. Shear bond strength characteristics on surface treatment modalities of CAD-CAM resin polymers. J Prosthodont 2025; 34:26-32. [PMID: 37940565 DOI: 10.1111/jopr.13790] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 11/05/2023] [Indexed: 11/10/2023] Open
Abstract
PURPOSE The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high-performance polymer material for fixed, screw-retained full arch restorations. MATERIAL AND METHODS A total of 135 computer-aided design and computer-aided manufacturing, high-performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm. The specimen surfaces were grouped as untreated (Group A), 50 μm Al2O3 (Group B), 110 μm Al2O3 (Group C), Rocatec (3 M, St. Paul, MN) activated with silica-modified alumina oxide treatment (Group D); and trimmed coarsely with a carbide bur (Group E). Group A samples were used as controls. After surface treatments, the specimens were gently cleansed with oil-free steam and alcohol wipes. Surface conditioning was performed on all physically treated samples. The manufacturer's recommendations were followed for bonding composite resin to the samples with light-cured Visio.link (Bredent, Chesterfield, UK). Cylinders were veneered with composite resins (diameter 5 mm, height 4 mm) and polymerized on the specimen surfaces through plastic tubes. Twenty-seven specimens were used for each testing group and aging tests were performed. The experimental samples were thermocycled. Shear bond strength and scanning electron microscopic tests were performed. Means and standard deviations were calculated. Statistical analysis was performed with post-hoc Tukey tests. RESULTS Statistical analysis revealed that there was a significant difference between the groups (p<0.001). The highest shear bond strengths were achieved for the specimens bonded with Visio.link without physical surface treatments (270.47 MPa). The lowest bond strengths were found for specimen surfaces abraded with 110 μm Al2O3 (117.03 Mpa) CONCLUSIONS: The results of this laboratory study indicated that the specimens used with Visio.link as provided by the manufacturer had the highest shear bond strengths between the composite resin and high-performance polymer test specimens. Modifications of the high-performance polymer surfaces with carbide burs did not change bonding strengths with the composite materials.
Collapse
Affiliation(s)
- Nikita Sinha
- Department of Prosthodontics, Creighton University School of Dentistry, Omaha, Nebraska, USA
| | - Geoffrey A Thompson
- Department of Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wisconsin, USA
| | - Carl Drago
- Department of Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wisconsin, USA
| | - Hongseok An
- Department of Restorative Dentistry, Graduate Prosthodontics OHSU, Portland, Oregon, USA
| |
Collapse
|
5
|
Yilmaz B, Donmez MB, Güven ME, Jamjoom FZ, Kahveci Ç, Schimmel M, Çakmak G. Trueness and fit of complete-arch implant-supported frameworks in new-generation additively and subtractively manufactured polymers: An in-vitro study. Clin Implant Dent Relat Res 2024; 26:986-997. [PMID: 38989676 DOI: 10.1111/cid.13362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 06/24/2024] [Accepted: 06/30/2024] [Indexed: 07/12/2024]
Abstract
BACKGROUND There is limited knowledge on the fabrication trueness and fit of additively or subtractively manufactured complete-arch implant-supported frameworks in recently introduced polymers. PURPOSE To evaluate the trueness and marginal fit of additively or subtractively manufactured polymer-based complete-arch implant-supported frameworks, comparing with those of strength gradient zirconia frameworks. MATERIALS AND METHODS A typodont model with 4 implants (left first molar (abutment 1), left canine (abutment 2), right canine (abutment 3), and right first molar (abutment 4)) was digitized (ATOS Core 80 5MP) and an implant-supported complete-arch framework was designed. This design file was used to fabricate frameworks from 5 different materials: strength gradient zirconia (SM-ZR), high impact polymer composite (SM-CR), nanographene-reinforced PMMA (SM-GR), PMMA (SM-PM), and additively manufactured temporary resin (AM) (n = 10). These frameworks were digitized and each scan file was virtually segmented into 4 regions (abutments, occlusal, overall without occlusal, and overall). The surface deviations at these regions, and linear and interimplant distance deviations were evaluated (Geomagic Control X). Marginal gaps were evaluated according to triple-scan protocol after seating frameworks on the model with the 1-screw test. Data were statistically analyzed (α = 0.05). RESULTS Surface deviations of all regions differed among tested materials (p ≤ 0.001). AM frameworks mostly had surface deviations that were similar to or lower than those of other materials (p ≤ 0.031), except for the occlusal surface, where it mostly had higher deviations (p ≤ 0.013). Abutment 4 of SM-CR had higher linear deviations than abutment 2 (p = 0.025), and material type did not affect the linear deviations within abutments (p ≥ 0.171). Interimplant distance deviations differed within and among materials (p ≤ 0.017), except for those between abutments 1 and 2 among materials (p = 0.387). Marginal gaps of subtractively manufactured materials differed among abutments, while those of abutments 3 and 4 differed among materials (p ≤ 0.003). AM frameworks mostly had lower marginal gaps at abutments 3 and 4 (p ≤ 0.048). CONCLUSIONS Although there was no clear trend among tested materials for measured deviations, marginal gaps of additively manufactured resin were mostly lower than those of subtractively manufactured materials and did not differ among abutment sites. Nevertheless, the differences in measured deviations among materials were small and marginal gaps were within the previously reported acceptability thresholds.
Collapse
Affiliation(s)
- Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, İstanbul, Turkey
| | - Mehmet Esad Güven
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Faris Z Jamjoom
- Restorative and Prosthetic Dental Science Department, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia
- King Abdullah International Medical Research Center (KAIMRC), Riyadh, Saudi Arabia
| | | | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
6
|
Shash YH. Mandibular biomechanics rehabilitated with different prosthetic restorations under normal and impact loading scenarios. BMC Oral Health 2024; 24:946. [PMID: 39143630 PMCID: PMC11325811 DOI: 10.1186/s12903-024-04681-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2024] [Accepted: 07/29/2024] [Indexed: 08/16/2024] Open
Abstract
BACKGROUND Restorative treatment options for edentulous patients range from traditional dentures to fixed restorations. The proper selection of materials greatly influences the longevity and stability of fixed restorations. Most prosthetic parts are frequently fabricated from titanium. Ceramics (e.g. zirconia) and polymers (e.g. PEEK and BIOHPP) have recently been included in these fabrications. The mandibular movement produces complex patterns of stress and strain. Mandibular fractures may result from these stresses and strains exceeding the critical limits because of the impact force from falls or accidents. Therefore, it is necessary to evaluate the biomechanical behavior of the edentulous mandible with different restorations under different loading situations. OBJECTIVE This study analyzes the biomechanical behavior of mandibles after four prosthetic restorations for rehabilitation under normal and impact loading scenarios. MATERIAL AND METHODS The mandibular model was constructed with a fixed restoration, which was simulated using various materials (e.g. Titanium, Zirconia & BIOHPP), under frontal bite force, maximum intercuspation, and chin impact force. From the extraction of tensile and compressive stresses and strains, as well as the total deformation of mandible segments, the biomechanical behavior and clinical situations were studied. RESULTS Under frontal bite, the anterior body exhibited the highest tensile (60.34 MPa) and compressive (108.81 MPa) stresses using restoration 4, while the condyles and angles had the lowest tensile (7.12 MPa) and compressive (12.67 MPa) stresses using restoration 3. Under maximum intercuspation, the highest tensile (40.02 MPa) and compressive (98.87 MPa) stresses were generated on the anterior body of the cortical bone using restoration 4. Additionally, the lowest tensile (7.7 MPa) and compressive (10.08 MPa) stresses were generated on the condyles and angles, respectively, using restoration 3. Under chin impact, the highest tensile (374.57 MPa) and compressive (387.3 MPa) stresses were generated on the anterior body using restoration 4. Additionally, the lowest tensile (0.65 MPa) and compressive (0.57 MPa) stresses were generated on the coronoid processes using restoration 3. For all loading scenarios, the anterior body of the mandible had the highest stress and strain values compared with the other segments. Compared to the traditional titanium restoration.2, restoration.1(zirconia) increases the tensile and compressive stresses and strains on the mandibular segments, in contrast to restoration.3 (BIOHPP). In addition, zirconia implants exhibited higher displacements than the other implants. CONCLUSION In the normal loading scenario, the tensile and compressive stresses and strains on the mandible were within the allowable limits when all restorations were used. Under the chin impact loading scenario, the anterior body of the mandible was damaged by restorations 1 and 4.
Collapse
Affiliation(s)
- Yomna H Shash
- Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.
| |
Collapse
|
7
|
Mourad KE, Rashed NHAH, Altonbary GY, Fattah Hegazy SA. Five years of radiographic evaluation for the peri-implant bone changes of all-on-four implant prostheses constructed from different framework materials using different digital construction techniques. BMC Oral Health 2024; 24:910. [PMID: 39112988 PMCID: PMC11308698 DOI: 10.1186/s12903-024-04642-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 07/22/2024] [Indexed: 08/10/2024] Open
Abstract
BACKGROUND There is insufficient evidence recommending a framework material and a CAD/CAM manufacturing technique for mandibular implant-supported prostheses. The study objective was to evaluate the clinical application of different materials and construction techniques used for mandibular All-on-4 prosthesis on circumferential peri-implant bony changes after 5 years. METHODS Thirty-six male patients with all-on-4 mandibular implant-supported prostheses were recalled and divided into three groups. Group PK (patients with frameworks milled from PEEK blocks), Group PSM (patients with frameworks milled from soft metal blocks), and Group SLM (patients with frameworks constructed with additive manufacturing; selective laser melting). The circumferential bone level on all implant faces was assessed with a CBCT. Two-way repeated measures ANOVA was used to compare vertical bone loss (VBL) and horizontal bone loss (HBL) between different groups, implant positions, and observation times followed by Tukey's multiple comparisons. RESULTS For all observation times, there was a significant difference in VBL between groups for both anterior and posterior implants (P < .001). For anterior implants, group PSM showed the lowest VBL while group PK showed the highest for anterior and posterior implants. For all groups, HBL significantly increased after 5 years for both anterior and posterior implants (P < .001). For anterior implants, group PSM showed the highest HBL. For posterior implants, group PK and SLM showed the highest. CONCLUSION Within the study's limitations, mandibular implant-supported fixed frameworks fabricated with either milling from PEEK or soft metal blocks, or additive manufacturing (laser melting technology) exhibited significant vertical and horizontal bone height changes after 5 years. CLINICAL TRIAL REGISTRY NUMBER (NCT06071689) (11/10/2023).
Collapse
Affiliation(s)
- Khloud Ezzat Mourad
- Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
| | | | | | | |
Collapse
|
8
|
Huang HY, Feng SW, Chiang KY, Li YC, Peng TY, Nikawa H. Effects of various functional monomers' reaction on the surface characteristics and bonding performance of polyetheretherketone. J Prosthodont Res 2024; 68:319-325. [PMID: 37574275 DOI: 10.2186/jpr.jpr_d_23_00063] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
PURPOSE Polyetheretherketone (PEEK) is a new polymeric material that has received significant attention in dentistry because of its mechanical properties, biocompatibility, and aesthetics. However, the bonding performance of PEEK to other materials is not preferable. This study aimed to analyze the variations in the surface characteristics of PEEK under the chemical action of primers containing different functional monomers or polymers and to evaluate the bonding performance of PEEK and dental cement. METHODS Disk-shaped PEEK samples were prepared by dental milling, blasting with alumina oxide, and covering with primers containing functional monomers or polymers. The surface characteristics of the samples were analyzed by microscopy and spectroscopy. The shear bond strength (SBS) between PEEK and dental cement, with and without thermocycling, was tested using a universal testing machine. Finally, the data were statistically analyzed and compared. RESULTS Functional monomers or polymers were successfully bonded to the surface of PEEK. This treatment significantly improved its hydrophilicity and surface free energy (P < 0.05). The primer containing pentaerythritol triacrylate had the highest SBS without thermocycling (13.89 MPa). Meanwhile, the primers containing urethane dimethacrylate (UDMA) and methyl methacrylate (MMA) (abbreviated as the HC group) showed the highest SBS and lowest reduction (25.51%) after thermocycling. Notably, all the testing groups achieved the ISO10477 standard of 5 MPa. After thermocycling, adhesive failure accounted for the largest proportion of failures in all the groups except the HC group. CONCLUSIONS The chemical priming treatment can significantly improve the SBS of PEEK and dental cement. Moreover, a primer containing both UDMA and MMA can provide improved bonding for PEEK materials.
Collapse
Affiliation(s)
- Huei-Yu Huang
- Department of Dentistry, Taipei Medical University Shuang Ho Hospital, New Taipei City, Taiwan
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Sheng-Wei Feng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Kuan-Yu Chiang
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yun-Chen Li
- Department of Dentistry, Taipei Medical University Shuang Ho Hospital, New Taipei City, Taiwan
| | - Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Hiroki Nikawa
- Department of Oral Biology & Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City, Hiroshima, Japan
| |
Collapse
|
9
|
Gama LT, Bezerra AP, Schimmel M, Rodrigues Garcia RCM, de Luca Canto G, Gonçalves TMSV. Clinical performance of polymer frameworks in dental prostheses: A systematic review. J Prosthet Dent 2024; 131:579-590. [PMID: 35422333 DOI: 10.1016/j.prosdent.2022.03.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 03/07/2022] [Accepted: 03/07/2022] [Indexed: 12/11/2022]
Abstract
STATEMENT OF PROBLEM High-performance polymers including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) have been used as substitutes for metal frameworks in dental prostheses. However, the clinical performance of polymer-based frameworks is still uncertain. PURPOSE The purpose of this systematic review was to compare the clinical performance of PEEK and PEKK with that of metal frameworks for different dental prostheses. MATERIAL AND METHODS This review follows the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Six databases and non-peer-reviewed literature (without language or follow-up restrictions) were searched for studies conducted before February 2022. Only clinical studies, either randomized clinical trials (RCTs) or nonrandomized clinical trials (N-RCTs), comparing the clinical performance of polymer and metal frameworks were included. The risk of bias and certainty of the evidence were assessed with the RoB 2.0, ROBINS-I, and GRADE. Biologic (plaque and gingival indices, probing depth, bleeding scores, implant stability quotient, marginal bone loss) and mechanical outcomes (ridge base relation, prosthetic marginal gap, and fracture) were assessed. RESULTS Only 9 studies (7 RCTs and 2 N-RCTs) were included, all with moderate to serious risk of bias and low to very low certainty of evidence. No meta-analysis was possible, but qualitative analysis revealed lower plaque and gingival indices, probing depth, and marginal bone loss, with higher survival rates for implant-supported fixed prostheses and overdentures fabricated with PEEK than for metal frameworks. No significant differences were found between groups for removable partial dentures. The marginal fit of PEEK frameworks was also better for single crowns. Three fractures were reported in the 3 PEKK fixed dental prostheses with cantilevers. CONCLUSIONS PEEK and PEKK seem to be promising materials for dental prostheses, with acceptable response from the periodontal tissue. However, further well-designed studies are necessary to better understand their clinical and long-term limitations.
Collapse
Affiliation(s)
- Lorena Tavares Gama
- PhD student, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Adriana Pinto Bezerra
- PhD student, Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | - Martin Schimmel
- Full Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern (UNIBE), Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva (UNIGE), Geneva, Switzerland
| | - Renata Cunha Matheus Rodrigues Garcia
- Full Professor, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Graziela de Luca Canto
- Full Professor, Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | | |
Collapse
|
10
|
Yilmaz B, Gouveia D, Schimmel M, Lu WE, Özcan M, Abou-Ayash S. Effect of adhesive system, resin cement, heat-pressing technique, and thermomechanical aging on the adhesion between titanium base and a high-performance polymer. J Prosthet Dent 2024; 131:468-474. [PMID: 35513915 DOI: 10.1016/j.prosdent.2022.03.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/21/2022] [Accepted: 03/21/2022] [Indexed: 11/25/2022]
Abstract
STATEMENT OF PROBLEM Even though polyetheretherketone (PEEK) has become popular for various prosthetic indications, a standard adhesive protocol to bond the PEEK to titanium bases has not been yet established. How the heat-pressing technique performs in this respect is also not clear. PURPOSE The purpose of this in vitro study was to investigate the effect of an adhesive system-cement combination, the heat-pressing technique, and thermomechanical aging on the retention force between titanium bases and PEEK specimens. MATERIAL AND METHODS Sixty 9×11×20-mm PEEK specimens with a titanium base slot integrated into the design were milled to simulate an implant-supported PEEK framework for a cantilevered fixed prosthesis. The specimens were assigned to 8 groups (n=10) according to the titanium base primer (MKZ or Monobond) and resin cement (DTK or Multilink hybrid) used and with or without thermomechanical aging. Twenty PEEK specimens were directly heat-pressed on titanium bases, and half of the specimens were not subjected to thermomechanical aging (n=10). For nonaged groups, the PEEK specimen complex was tightened to an implant analog and secured on a custom-made pull-off device. Retention forces were measured by using the pull-off tensile test in a universal testing machine, and the maximum tensile bond strength (MPa) was calculated. The aged groups were subjected to 5000 cycles of thermal aging (5 °C to 55 °C), and the specimens were clamped to load the extension (cantilever) for 1 200 000 cycles with 120 N and 200 N at 1.5-Hz frequency. After aging, the pull-off test was performed for those specimens that survived thermomechanical aging. A nonparametric Kruskal-Wallis test was used to determine whether there was a difference among the groups, followed by pairwise Wilcoxon rank tests with Bonferroni correction. The Wilcoxon rank test was used to analyze the effect of thermomechanical aging in each adhesive system-cement or heat-press group (α=.05 for all tests). RESULTS None of the specimens failed during cyclic loading. According to the Kruskal-Wallis test, the effect of the PEEK-Ti base bonding technique on the retention force in the nonaged (P=.019) and thermomechanically aged groups was significant (P=.010). In the nonaged groups, the heat-pressing technique resulted in a higher retention force than when the specimens were bonded by using the Monobond-Multilink hybrid combination (P=.031). Thermomechanical aging did not significantly affect the results (P>.241). All failures were adhesive, with cement remaining only on the Ti-bases. CONCLUSIONS All bonding protocols tested resulted in a stable bond between PEEK and Ti-bases, as all specimens survived thermomechanical aging. The heat-pressing technique resulted in mean bond strength values similar to those obtained with the tested adhesive system-cement combinations with 1 exception; the nonaged heat-pressed groups presented higher bond strength than the Monobond-Multilink hybrid combination. Failure types indicated that the weaker bond was between the PEEK and the cements tested rather than between the titanium base and the cements, regardless of the adhesive system-cement combination.
Collapse
Affiliation(s)
- Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| | - Diogo Gouveia
- Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| | - Martin Schimmel
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland; Senior Lecturer, Extra muros, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Wei-En Lu
- PhD Candidate, Division of Biostatistics, The Ohio State University College of Public Health, Columbus, Ohio
| | - Mutlu Özcan
- Professor and Head, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Samir Abou-Ayash
- Senior Lecturer and Head, Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
| |
Collapse
|
11
|
Atsu S, Erol U. Marginal fit and fracture resistance of polyetheretherketone, zirconia, and titanium implant-supported prosthesis frameworks for a partially edentulous arch after thermomechanical aging. J Prosthet Dent 2024; 131:273-280. [PMID: 37620182 DOI: 10.1016/j.prosdent.2023.07.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 07/11/2023] [Accepted: 07/12/2023] [Indexed: 08/26/2023]
Abstract
STATEMENT OF PROBLEM Although polyetheretherketone (PEEK) and zirconia (Zir) have been used as implant-supported prosthesis (ISP) frameworks, the long-term effects of thermomechanical aging on the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with titanium (Ti) bases for patients with a partially edentulous arch are not clear. PURPOSE The purpose of this in vitro study was to determine the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with Ti bases and Ti ISP frameworks for partially edentulous arches after aging. MATERIAL AND METHODS A total of 30 ISP epoxy resin casts were obtained from a typodont with 1 straight implant (Nobel Biocare) in the mandibular right canine region and 1 implant with a 30-degree distal tilt in the mandibular right first molar region. All frameworks (n=10) were fabricated on their own epoxy resin cast with multiunit abutment replicas by using a computer-aided design and computer-aided manufacturing system (exocad-Yenadent). The PEEK and Zir frameworks were fabricated with Ti-bases. Primer (MKZ) and resin cement (DTK adhesive) were used to cement the frameworks to the Ti-bases under a static load of 10 N. After thermomechanical aging (1.2×106 cycles, 120 N, 5 °C-55 °C), marginal gaps between the Ti-bases and cemented frameworks and vertical and passive fits between the Ti-bases and framework and multi-unit abutments were measured by using a stereomicroscope (Euromex) at ×100 magnification. Fracture resistances and types were then determined by using a universal test machine and a stereomicroscope at ×40 magnification. Data were analyzed by using 1-way analysis of variance (ANOVA) and the Tukey HSD and Fisher-Freeman-Halton tests (α=.05). RESULTS The marginal gaps of the PEEK and Zir frameworks were respectively 83.5 ±27.1 and 81.8 ±17.8 µm. PEEK (23.7 ±4.6) and Zir (32.9 ±8.7) had a better vertical fit (µm) than Ti (52.5 ±10.6) (P<.001). Zir (49.3 ±16.2) (P<.001) and PEEK (70.9 ±19.6) (P>.05) frameworks had better passive fit (µm) than Ti (91.3 ±24.2). Ti had the highest mean fracture resistance (N) (14800.2 ±3442.3) followed by Zir (7318.7 ±1385.1) and PEEK (3448.9 ±486.6) (P<.001). Fracture types were different in different groups (P<.001). CONCLUSIONS The PEEK and Zir frameworks with Ti bases had better vertical and passive fit than the Ti frameworks. All ISP frameworks represented mean marginal fit below 92 µm and withstood physiologic occlusal forces after thermomechanical aging.
Collapse
Affiliation(s)
- Saadet Atsu
- Professor, Research Assistant, Department of Prosthodontics, Faculty of Dentistry, University of Kırıkkale, Kırıkkale, Turkey; Visiting Professor, Materials Engineering, McGill University, Montreal, Canada..
| | - Ulas Erol
- Professor, Research Assistant, Department of Prosthodontics, Faculty of Dentistry, University of Kırıkkale, Kırıkkale, Turkey
| |
Collapse
|
12
|
Mory N, Cascos R, Celemín-Viñuela A, Gómez-Polo C, Agustín-Panadero R, Gómez-Polo M. Comparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: An In Vitro Study. Biomedicines 2023; 11:3036. [PMID: 38002036 PMCID: PMC10669478 DOI: 10.3390/biomedicines11113036] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 11/02/2023] [Accepted: 11/06/2023] [Indexed: 11/26/2023] Open
Abstract
The roughness of the intra-oral surfaces significantly influences the initial adhesion and the retention of microorganisms. The aim of this study was to analyze the surface texture of four different CAD-CAM materials (two high-performance polymers and two fifth-generation zirconia) used for complete-arch implant-supported prostheses (CAISPs), and to investigate the effect of artificial aging on their roughness. A total of 40 milled prostheses were divided into 4 groups (n = 10) according to their framework material, bio.HPP (B), bio.HPP Plus (BP), zirconia Luxor Z Frame (ZF), and Luxor Z True Nature (ZM). The areal surface roughness "Sa" and the maximum height "Sz" of each specimen was measured on the same site after laboratory fabrication (lab as-received specimen) and after thermocycling (5-55 °C, 10,000 cycles) by using a noncontact optical profilometer. Data were analyzed using SPSS version 28.0.1. One-way ANOVA with multiple comparison tests (p = 0.05) and repeated measures ANOVA were used. After thermocycling, all materials maintained "Sa" values at the laboratory as-received specimen level (p = 0.24). "Sz" increased only for the zirconia groups (p = 0.01). B-BP exhibited results equal/slightly better than ZM-ZF. This study provides more realistic surface texture values of new metal-free materials used in real anatomical CAISPs after the manufacturing and aging processes and establishes a detailed and reproducible measurement workflow.
Collapse
Affiliation(s)
- Nataly Mory
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
| | - Rocío Cascos
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28670 Madrid, Spain
| | - Alicia Celemín-Viñuela
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
| | - Cristina Gómez-Polo
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain;
| | - Rubén Agustín-Panadero
- Prosthodontic and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain;
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
| |
Collapse
|
13
|
Peng TY, Ma TL, Lee IT, Wu SH, Mine Y, Lin CC. Enhancing Dental Cement Bond Strength with Autofocus-Laser-Cutter-Generated Grooves on Polyetheretherketone Surfaces. Polymers (Basel) 2023; 15:3670. [PMID: 37765524 PMCID: PMC10536987 DOI: 10.3390/polym15183670] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/21/2023] [Accepted: 08/30/2023] [Indexed: 09/29/2023] Open
Abstract
Polyetheretherketone (PEEK) is widely used in dentistry owing to its exceptional properties, including its natural appearance; however, existing surface treatment methods for bonding PEEK have limitations. Autofocus laser cutters, known for their precise engraving and cutting capabilities, offer potential for surface treatment of PEEK; thus, the objective of this study was to investigate the creation of laser groove structures on PEEK to enhance its bonding capability with dental resin cement. A dental computer-aided design and manufacturing system was used to fabricate PEEK samples, and three groove patterns (circle, line, and grid) were generated on PEEK surfaces, with air-abrasion used as the control group. The surface characteristics, cell viability, and bond strength were evaluated, and the data were statistically analyzed using one-way analysis of variance and post hoc Tukey's tests (α = 0.05). Laser-treated PEEK exhibited a uniform texture with a groove depth of approximately 39.4 µm, hydrophobic properties with a contact angle exceeding 90°, a surface roughness of 7.3-12.4 µm, consistent topography, and comparable cell viability compared with untreated PEEK. Despite a decrease in bond strength after thermal cycling, no significant intergroup differences were observed, except for the line-shaped laser pattern. These findings indicate that the autofocus laser cutter effectively enhances the surface characteristics of PEEK by creating a uniform texture and grooves, showing promise in improving bonding properties, even considering the impact of thermal cycling effects.
Collapse
Affiliation(s)
- Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (T.-Y.P.); (S.-H.W.)
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Tien-Li Ma
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - I-Ta Lee
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (T.-Y.P.); (S.-H.W.)
| | - Sheng-Han Wu
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (T.-Y.P.); (S.-H.W.)
| | - Yuichi Mine
- Department of Medical Systems Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan;
| | - Chia-Cheng Lin
- Department of Dentistry, Shin Kong Wu Ho-Su Memorial Hospital, Taipei 11101, Taiwan
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| |
Collapse
|
14
|
Al-Asad HM, El Afandy MH, Mohamed HT, Mohamed MH. Hybrid Prosthesis versus Overdenture: Effect of BioHPP Prosthetic Design Rehabilitating Edentulous Mandible. Int J Dent 2023; 2023:4108679. [PMID: 37426766 PMCID: PMC10325880 DOI: 10.1155/2023/4108679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/24/2023] [Accepted: 05/29/2023] [Indexed: 07/11/2023] Open
Abstract
Aim To compare the BioHPP (biocompatible high-performance polymer) as a substructure for the hybrid prosthesis versus the BioHPP bar supporting and retaining implant overdenture by radiographic evaluation to identify bone height alteration around the implants and to evaluate satisfaction based on visual analoge scale questionnaire. Materials and Methods Ill-fitting mandibular dentures were chosen for 14 fully edentulous male patients with adequate dental hygiene, enough interarch space, and free of systemic diseases and parafunctional habits. Patients who received new dentures (CDs) were randomly allocated into each group using computer software, and four interforaminal implants were inserted in parallel using a surgical guide. Three months after osseointegration, the patients received either CAD-CAM BioHPP framework hybrid prosthesis (Group I) or BioHPP bar supported and retained overdenture (Group II). Using digital preapical radiography, the bone loss is evaluated 6, 12, and 18 months after insertion. The subjective patient evaluation was done using a questionnaire based on the VAS includes five points for chewing, comfort, esthetics, speech, oral hygiene, and general satisfaction. Results The overall marginal bone loss (MBL) revealed that Group I (hybrid prosthesis) was more than Group II (bar overdenture) at all intervals in the anterior and posterior implants' mesial and distal surfaces. The patient satisfaction survey results showed that, after 18 months, the difference was statistically not significant between them all (P > 0.05) except for the comfort (for the overdenture group, 4.43 ± 0.53 while the fixed hybrid was 5.00 ± 0.00). Conclusion BioHPP framework material is an alternative material for implant rehabilitation of edentulous mandible with minimal MBL in BioHPP bar overdenture compared to BioHPP hybrid prosthesis.
Collapse
Affiliation(s)
- Hanan Mohsen Al-Asad
- Faculty of Dentistry, Aden University, Aden, Yemen
- University of Science and Technology, Aden, Yemen
| | | | | | | |
Collapse
|
15
|
Cevik P, Yildirim AZ, Demir Sevinc EH, Gonder A, Kiat-Amnuay S. Using Peek as a Framework Material for Maxillofacial Silicone Prosthesis: An In Vitro Study. Polymers (Basel) 2023; 15:2694. [PMID: 37376341 DOI: 10.3390/polym15122694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/09/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
There are often bonding problems between acrylic resins and silicone. PEEK (polyetheretherketone), which is a high-performance polymer, has great potential for the implant, and fixed or removable prosthodontics. The aim of this study was to evaluate the effect of different surface treatments on PEEK to be bonded to maxillofacial silicone elastomers. A total of 48 specimens were fabricated from either PEEK or PMMA (Polymethylmethacrylate) (n = 8). PMMA specimens acted as a positive control group. PEEK specimens were divided into five study groups as surface treatments as control PEEK, silica-coating, plasma etching, grinding, or nano-second fiber laser. Surface topographies were evaluated by scanning electron microscopy (SEM). A platinum-primer was used on top of all specimens including control groups prior to silicone polymerization. The peel bond strength of the specimens to a platinum-type silicone elastomer was tested at a cross-head speed of 5 mm/min. The data were statistically analyzed (α = 0.05). The control PEEK group showed the highest bond strength (p < 0.05) among the groups. No statistical difference was found between control PEEK, grinding, or plasma etching groups (p > 0.05). The lowest bond strength was seen in the laser group, which was not statistically different from silica-coating (p > 0.05), and statistically different from control PEEK, grinding, or plasma groups (p < 0.05). Positive control PMMA specimens had statistically lower bond strength than either control PEEK or plasma etching groups (p < 0.05). All specimens exhibited adhesive failure after a peel test. The study results indicate that PEEK could serve as a potential alternative substructure for implant-retained silicone prostheses.
Collapse
Affiliation(s)
- Pinar Cevik
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
- Department of General Practice and Dental Public Health, School of Dentistry, The University of Texas Health Science Center at Houston, Houston, TX 77054, USA
- Houston Center of Biomaterials and Biomimetics, Houston, TX 77054, USA
| | - Arzu Zeynep Yildirim
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
| | | | - Aykut Gonder
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
| | - Sudarat Kiat-Amnuay
- Department of General Practice and Dental Public Health, School of Dentistry, The University of Texas Health Science Center at Houston, Houston, TX 77054, USA
- Houston Center of Biomaterials and Biomimetics, Houston, TX 77054, USA
| |
Collapse
|
16
|
Gouda A, Sherif A, Wahba M, Morsi T. Effect of veneering material type and thickness ratio on flexural strength of bi-layered PEEK restorations before and after thermal cycling. Clin Oral Investig 2023; 27:2629-2639. [PMID: 36602589 PMCID: PMC10264476 DOI: 10.1007/s00784-022-04829-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 12/18/2022] [Indexed: 01/06/2023]
Abstract
OBJECTIVE The purpose of this study was evaluating the biaxial strength of bi-layered PEEK restorations before and after aging using different veneering materials in different thickness ratios. MATERIAL AND METHODS Ninety specimens of thickness 1.5 mm were divided into three groups according to their veneering material. Group (CAD LD): BioHPP discs veneered with CAD milled lithium disilicate (n=30), group (CAD C): BioHPP discs veneered with CAD milled composite (n=30), and group (LC): BioHPP discs veneered with conventionally layered composite (n=30). Each group was subdivided into 3 subgroups (n=10) according to the different thickness ratios between the core and the veneering material (TC:TV). Subgroup 1: TC:TV=1:0.5, subgroup 2: TC:TV=0.7:0.8, and subgroup 3: TC:TV=0.5:1. Half of the specimens of each subgroup were subjected to thermocycling, and the bi-axial flexural strength of all specimens was tested before and after aging. Three-way ANOVA followed by Bonferroni's post hoc test were used for data analysis. The significance level was set at P ≤ 0.05. RESULTS Material, thickness ratio, and aging all had a significant effect on biaxial flexural strength. (LC) group had the highest biaxial flexural strength. TC:TV=0.5:1 showed the lowest biaxial flexural strength. All groups showed significant decrease in biaxial flexural strength after aging. CONCLUSIONS Veneering material for PEEK together with the thickness ratio between the core and veneering material greatly affect the flexural strength of bi-layered restorations. Thermocycling negatively impacts the flexural strength of PEEK bi-layered restorations. CLINICAL SIGNIFICANCE According to the results of that study, PEEK cores are best veneered with conventionally layered composite with core to veneering thickness ratio being 1:0.5.
Collapse
Affiliation(s)
- Ahmed Gouda
- Postgraduate Student, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| | - Ashraf Sherif
- Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| | - Mennatallah Wahba
- Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| | - Tarek Morsi
- Fixed Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
- Vice Dean Postgraduate Affairs. Faculty of Oral and Dental Medicine, Misr International University, Cairo, Egypt
| |
Collapse
|
17
|
Erjavec AK, Črešnar KP, Švab I, Vuherer T, Žigon M, Brunčko M. Determination of Shear Bond Strength between PEEK Composites and Veneering Composites for the Production of Dental Restorations. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093286. [PMID: 37176168 PMCID: PMC10178894 DOI: 10.3390/ma16093286] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 04/19/2023] [Accepted: 04/20/2023] [Indexed: 05/15/2023]
Abstract
We studied the shear bond strength (SBS) of two PEEK composites (BioHPP, BioHPP plus) with three veneering composites: Visio.lign, SR Nexco and VITA VM LC, depending on the surface treatment: untreated, sandblasted with 110 μm Al2O3, sandblasted and cleaned ultrasonically in 80% ethanol, with or without adhesive Visio.link, with applied Visio.link and MKZ primer. For the BioHPP plus, differential scanning calorimetry (DSC) revealed a slightly lower glass transition temperature (Tg 150.4 ± 0.4 °C) and higher melting temperature (Tm 339.4 ± 0.6 °C) than those of BioHPP (Tg 151.3 ± 1.3 °C, Tm 338.7 ± 0.2 °C). The dynamical mechanical analysis (DMA) revealed a slightly higher storage modulus of BioHPP (E' 4.258 ± 0.093 GPa) than of BioHPP plus (E' 4.193 ± 0.09 GPa). The roughness was the highest for the untreated BioHPP plus, and the lowest for the polished BioHPP. The highest hydrophobicity was achieved on the sandblasted BioHPP plus, whereas the highest hydrophilicity was found on the untreated BioHPP. The highest SBSs were determined for BioHPP and Visio.lign, adhesive Visio.link (26.31 ± 4.17 MPa) or MKZ primer (25.59 ± 3.17 MPa), with VITA VM LC, MKZ primer and Visio.link (25.51 ± 1.94 MPa), and ultrasonically cleaned, with Visio.link (26.28 ± 2.94 MPa). For BioHPP plus, the highest SBS was determined for a sandblasted surface, cleaned ultrasonically, with the SR Nexco and Visio.link (23.39 ± 2.80 MPa).
Collapse
Affiliation(s)
| | - Klementina Pušnik Črešnar
- Faculty of Polymer Technology, Ozare 19, 2380 Slovenj Gradec, Slovenia
- Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
| | - Iztok Švab
- Isokon d.o.o., Industrijska cesta 16, 3210 Slovenske Konjice, Slovenia
| | - Tomaž Vuherer
- Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
| | - Majda Žigon
- Faculty of Polymer Technology, Ozare 19, 2380 Slovenj Gradec, Slovenia
| | - Mihael Brunčko
- Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
| |
Collapse
|
18
|
Attia MA, Blunt L, Bills P, Tawfik A, Radawn M. Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns. J Prosthet Dent 2023:S0022-3913(23)00183-X. [PMID: 37072286 DOI: 10.1016/j.prosdent.2023.03.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/18/2023] [Accepted: 03/20/2023] [Indexed: 04/20/2023]
Abstract
STATEMENT OF PROBLEM Polyetheretherketone (PEEK) has been increasingly used as a framework material in prosthetic dentistry. However, data on the marginal and internal fit of PEEK restorations fabricated by using either the computer-aided design and computer-aided manufacturing (CAD-CAM) or heat-pressing technique are sparse. PURPOSE The aim of this in vitro study was to assess the marginal and internal fit of milled and pressed PEEK single crowns by using microcomputed tomography (μCT). MATERIAL AND METHODS A custom-made, single stainless-steel die was designed to replicate a maxillary first premolar prepared for a ceramic crown. PEEK copings (N=30) were fabricated and allocated to 3 groups (n=10) according to the fabrication technique: milled from a prefabricated PEEK blank, heat pressed from PEEK pellets, and heat pressed from PEEK granules. All copings were veneered with a composite resin material. The marginal fit was recorded at 4 predetermined points and the internal fit at 8 predetermined points on each crown by using μCT. Two-way ANOVA, pair-wise Tukey honestly significant difference (HSD), and simple main effect tests were used for statistical analysis of the data (α=.05). RESULTS Concerning marginal fit, the milled crowns demonstrated the best marginal fit overall (44 ±3 μm), followed by those pressed from pellets (92 ±3 μm), and finally by those pressed from granules (137 ±7 μm) (P<.001). The interaction between the effects of the fabrication technique and the measurement point on the marginal fit was not statistically significant (P=.142). The milled crowns demonstrated the lowest mean gap values overall, followed by those pressed from pellets and those pressed from granules (P<.001). The interaction between the effects of the fabrication technique and the measurement point on the internal fit was statistically significant (P<.001). Except for the distal occlusal gap and mesial occlusal gap, all tested groups showed a statistically significant difference (P<.001). In addition, statistically significant differences were observed among all measurement points in different fabrication techniques (P<.001). CONCLUSIONS The marginal and internal fit of milled PEEK crowns was significantly better than pressed crowns. However, both CAD-CAM and heat-pressing techniques produced PEEK crowns with a clinically acceptable marginal and internal fit. The mean marginal gap of the PEEK crowns pressed from granules was above the range of clinically acceptable value.
Collapse
Affiliation(s)
- Mazen A Attia
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt.
| | - Liam Blunt
- Professor, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Paul Bills
- Professor, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Ahmed Tawfik
- PhD Researcher, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Mohamed Radawn
- Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
| |
Collapse
|
19
|
Ellakany P, Madi M, Aly NM, Alshehri T, Alameer ST, Al-Harbi FA. Influences of Different CAD/CAM Ceramic Compositions and Thicknesses on the Mechanical Properties of Ceramic Restorations: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16020646. [PMID: 36676383 PMCID: PMC9865408 DOI: 10.3390/ma16020646] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 12/24/2022] [Accepted: 12/26/2022] [Indexed: 05/14/2023]
Abstract
The aim of this study was to assess the influences of different CAD/CAM ceramic compositions and thicknesses on the surface roughness and hardness of ceramic restorations. Four different ceramics were used in the current study: lithium disilicate (LD), leucite reinforced (LE), advanced lithium disilicate (ALD), and zirconia-reinforced lithium silicate (ZLS). Each group included 30 specimens subdivided into three different ceramic thicknesses (0.5, 1 and 1.5 mm thicknesses). The microhardness was measured for all the specimens using a microhardness testing machine, while the surface roughness was measured using a non-contact optical profilometer at three intervals (before toothbrushing and after toothbrushing, with and without toothpaste). Three-way and two-way ANOVA were used to determine the factors influencing the surface roughness and microhardness. There was a significant difference in the surface roughness between the studied groups for all the thicknesses. The findings showed that ALD had the lowest surface roughness, while ZLS showed the highest surface roughness. Moreover, ALD, followed by ZLS, had the highest hardness, while LD and LE had the lowest hardness values. Regarding the thicknesses, both the 0.5 and 1 mm ceramic thicknesses showed a significantly lower surface roughness than the 1.5 mm thickness, while the 1.5 mm thickness showed a significantly higher microhardness than the 0.5 mm thickness. The surface roughness and hardness were significantly affected by the ceramic composition and type of filler. It is recommended to use 1.5 mm-thick ceramic materials for the fabrication of definitive full-coverage ceramic restorations, while veneers require 0.5 mm-thick materials. ALD is a promising CAD/CAM material that can be used for the fabrication of restorations with a proper strength in both anterior and posterior regions.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
- Correspondence: ; Tel.: +966-547812107
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shahad T. Alameer
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| |
Collapse
|
20
|
Checinska K, Checinski M, Cholewa-Kowalska K, Sikora M, Chlubek D. Polyphenol-Enriched Composite Bone Regeneration Materials: A Systematic Review of In Vitro Studies. Int J Mol Sci 2022; 23:ijms23137473. [PMID: 35806482 PMCID: PMC9267334 DOI: 10.3390/ijms23137473] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 06/27/2022] [Accepted: 07/04/2022] [Indexed: 11/16/2022] Open
Abstract
One of the possible alternatives for creating materials for the regeneration of bone tissue supporting comprehensive reconstruction is the incorporation of active substances whose controlled release will improve this process. This systematic review aimed to identify and synthesize in vitro studies that assess the suitability of polyphenolics as additives to polymer-ceramic composite bone regeneration materials. Data on experimental studies in terms of the difference in mechanical, wettability, cytocompatibility, antioxidant and anti-inflammatory properties of materials were synthesized. The obtained numerical data were compiled and analyzed in search of percentage changes of these parameters. The results of the systematic review were based on data from forty-six studies presented in nineteen articles. The addition of polyphenolic compounds to composite materials for bone regeneration improved the cytocompatibility and increased the activity of early markers of osteoblast differentiation, indicating a high osteoinductive potential of the materials. Polyphenolic compounds incorporated into the materials presumably give them high antioxidant properties and reduce the production of reactive oxygen species in macrophage cells, implying anti-inflammatory activity. The evidence was limited by the number of missing data and the heterogeneity of the data.
Collapse
Affiliation(s)
- Kamila Checinska
- Department of Glass Technology and Amorphous Coatings, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Cracow, Poland;
- Correspondence: (K.C.); (D.C.)
| | - Maciej Checinski
- Department of Oral Surgery, Preventive Medicine Center, Komorowskiego 12, 30-106 Cracow, Poland;
| | - Katarzyna Cholewa-Kowalska
- Department of Glass Technology and Amorphous Coatings, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Cracow, Poland;
| | - Maciej Sikora
- Department of Maxillofacial Surgery, Hospital of the Ministry of Interior, Wojska Polskiego 51, 25-375 Kielce, Poland;
- Department of Biochemistry and Medical Chemistry, Pomeranian Medical University, Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland
| | - Dariusz Chlubek
- Department of Biochemistry and Medical Chemistry, Pomeranian Medical University, Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland
- Correspondence: (K.C.); (D.C.)
| |
Collapse
|
21
|
Gouveia D, Yilmaz B, Cevik P, Johnston WM. Using Kubelka-Munk reflectance theory to predict optimal pink composite thickness and shade with an opaqued PEEK background for a final gingival color: An in vitro study. Dent Mater 2022; 38:1452-1458. [DOI: 10.1016/j.dental.2022.06.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 06/12/2022] [Accepted: 06/22/2022] [Indexed: 11/03/2022]
|
22
|
Applications and Clinical Behavior of BioHPP in Prosthetic Dentistry: A Short Review. JOURNAL OF COMPOSITES SCIENCE 2022. [DOI: 10.3390/jcs6030090] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
(1) Background: BioHPP® (Bredent, UK) is a partially crystalline poly ether ether ketone (PEEK) that is strengthened using ceramic. PEEK and its various formulations represent a very interesting alternative, and has been in-depth with its literature in recent years; (2) Methods: A PubMed and Scopus search for the term “BioHPP” yielded 73 results and 42 articles which were included in this short review. Considering the scarce literature on the subject, each article was considered in this review; (3) Results: the articles analyzed are very recent, all published in the last 5 years. Their clinical evaluation of BioHPP® highlights many positive aspects, and few articles have highlighted critical issues in its multiple clinical applications; (4) Conclusions: this material is not only extremely interesting for the future, but possesses characteristics suitable for clinical application today, for endocrowns, small adhesive bridges, temporary prostheses and for immediate loads on implant restorations. The excellent aesthetics and the possibility of simple reprocessing of the restorations made with this material invite its clinical application.
Collapse
|
23
|
New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies. BIOMED RESEARCH INTERNATIONAL 2022; 2022:3074182. [PMID: 35281596 PMCID: PMC8906986 DOI: 10.1155/2022/3074182] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 01/05/2022] [Accepted: 02/02/2022] [Indexed: 12/31/2022]
Abstract
Innovations in digital manufacturing enabled the fabrication of implant-supported fixed dental prostheses (ISFDPs) in a wide variety of recently introduced materials. Computer-aided design and computer-aided manufacturing (CAD-CAM) milling allows the fabrication of ISFDPs with high accuracy by reducing the fabrication steps of large-span frameworks. The longevity of ISFDPs depends on the overall mechanical properties of the framework material including its fit, and the physical properties of the veneering material and its bond with the framework. This comprehensive review summarizes the recent information on millable CAD-CAM framework materials such as pre-sintered soft alloys, fiber-reinforced composite resins, PEEK, and PEKK in high-performance polymer family, and 4Y-TZP. Even though promising results have been obtained with the use of new generation millable CAD-CAM materials for ISFDPs, clinical studies are lacking and future research should focus on the overall performance of these millable materials in both static and dynamic conditions.
Collapse
|
24
|
Evaluation of Zirconia and High Performance Polymer Abutment Surface Roughness and Stress Concentration for Implant-Supported Fixed Dental Prostheses. COATINGS 2022. [DOI: 10.3390/coatings12020238] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Background: The High Performance Polymer is a based polymer biomaterial that was introduced as dental material to manufacture dentures superstructure and dental implants abutments. However, its surface characteristics and stress state still need to be properly described. The aim of this study was to compare the surface characteristics of a High Performance Polymer (Bio-HPP, Bredent, Senden, Germany) for computer-aided design and computer-aided manufacturing (CAD/CAM) milling and a Zirconia (Zirkonzahn, Steger, Ahrntal, Italy). Methods: The abutments surface roughness (Ra) was evaluated for each abutment material (N = 12) using a confocal laser microscope. Data were evaluated using One-Way ANOVA and Tukey tests (p < 0.05). In addition, a finite element analysis software was used to present stress measurement data as stress maps with 100 N loading. Results were generated according to Von-mises stress criteria and stress peaks were recorded from each structure. Results: Results showed a mean Ra of 0.221 ± 0.09 μm for Bio-HPP and 1.075 ± 0.24 μm for Zirconia. Both surface profiles presented a smooth characteristic regardless the measurement axis. The stress peaks from implant fixture and screw were not affected by the abutment material, however the high performance polymer showed the highest stress magnitude for the abutment region. Conclusions: Comparing the present results with the literature it is suggested that the CAD/CAM High Performance Polymer abutments present an adequate surface roughness with acceptable values of stress.
Collapse
|
25
|
Diken Turksayar AA, Hisarbeyli D, Seçkin Kelten Ö, Bulucu NB. Wear behavior of current computer-aided design and computer-aided manufacturing composites and reinforced high performance polymers: An in vitro study. J ESTHET RESTOR DENT 2021; 34:527-533. [PMID: 34655152 DOI: 10.1111/jerd.12828] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 10/01/2021] [Accepted: 10/04/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To analyze the wear rate of computer-aided design and computer-aided manufacturing (CAD/CAM) composites, polyetheretherketones and glass ceramics. MATERIAL AND METHODS Our study groups were prepared from two different resin-based composites (Brillant Crios, Cerasmart), a glass ceramic (IPS Emax CAD) and reinforced polyetheretherketone (BioHPP) material (n = 10). Premolar teeth were used as antagonists. The specimens, which were subjected to two body wear tests (240,000 cycles, 1.2 Hz, 50N) in the chewing simulator, were scanned with a 3D laser scanner both before and after the wear test. Volume loss and wear depth were determined by means of the obtained images software program. The wear pattern was examined by scanning electron microscopy. Kruskal Wallis test served for analyzing. RESULTS The least volume loss and wear depth were seen in the polyetheretherketone material (0.06 ± 0.04 mm3 , 0.02 ± 0.01 mm), while the maximum volume loss was seen in the groups containing resin-based composite. (p = 0.05). The volume loss value in glass ceramics is between CAD/CAM composites and polyetheretherketone. CONCLUSION The behavior of polyetheretherketone against enamel was different from glass ceramics and composite materials in terms of the amount of wear. CLINICAL SIGNIFICANCE Polyetheretheketone can be considered as an alternative to other chairside materials in terms of wear resistance.
Collapse
Affiliation(s)
| | - Duygu Hisarbeyli
- Department of Restorative Dentistry, Oral and Dental Health Center, İstanbul, Turkey
| | - Özlem Seçkin Kelten
- Department of Restorative Dentistry, Oral and Health Center, Kırıkkale, Turkey
| | - Naime Bilinç Bulucu
- Faculty of Dentistry, Department of Restorative Dentistry, Biruni University, İstanbul, Turkey
| |
Collapse
|
26
|
Wang J, Wu P, Liu HL, Zhang L, Liu LP, Ma CF, Chen JH. Polyetheretherketone versus titanium CAD-CAM framework for implant-supported fixed complete dentures: a retrospective study with up to 5-year follow-up. J Prosthodont Res 2021; 66:279-287. [PMID: 34588401 DOI: 10.2186/jpr.jpr_d_20_00142] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the performance of polyetheretherketone (PEEK) versus titanium computer-aided designed and manufactured (CAD-CAM) framework for implant-supported fixed complete dentures (ISFCDs) with a follow-up for a duration of up to 5 years. METHODS Consecutively edentulous patients who underwent ISFCDs with a PEEK framework or titanium framework at one dental specialist center were included in this retrospective study. Implant/prosthesis survival rates, mechanical/biological complications, and bone and soft tissue parameters were analyzed. Overall survival was analyzed using Kaplan-Meier survival curves and the log-rank test. RESULTS Sixty ISFCDs (29 PEEK, 31 titanium) performed on 43 edentulous patients (331 implants) were included. An implant survival rate of 100% was obtained. There was no significant difference in the cumulative prosthesis survival rate between the PEEK (93.1%) and titanium groups (93.5%). The most common mechanical complications were fracture of the artificial veneer in both the PEEK (13.8%) and titanium (16.7%) groups. Bruxers had a higher prevalence of mechanical complications than non-bruxers (p<0.05). The biological complications included bleeding upon probing (13.8% for the PEEK group; 16.1% for the titanium group), soft tissue inflammation (3.4% for the PEEK group; 3.2% for the titanium group), and temporomandibular disorders (6.5% for the titanium group). The vertical bone loss was significantly lower in the PEEK group (0.70 mm) than in the titanium group (0.96 mm). Smokers had a significantly higher prevalence of biological complications than non-smokers. CONCLUSIONS Within the limitations of this study, ISFCDs with PEEK frameworks can provide good prognosis for edentulous patients, still requiring longer-term validation.
Collapse
Affiliation(s)
- Jing Wang
- National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.,Key Laboratory of Shaanxi Province for Craniofacial Precision Medical Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, China
| | - Peng Wu
- Department of Stomatology, Peking University People's Hospital, Beijing, China
| | | | - Ling Zhang
- National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Li-Peng Liu
- National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Chu-Fan Ma
- National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.,Air Force Medical Center, The Fourth Military Medical University, Beijing, China
| | - Ji-Hua Chen
- National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| |
Collapse
|
27
|
Trueness and marginal fit of implant-supported complete-arch fixed prosthesis frameworks made of high-performance polymers and titanium: An explorative in-vitro study. J Dent 2021; 113:103784. [PMID: 34419479 DOI: 10.1016/j.jdent.2021.103784] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 08/11/2021] [Accepted: 08/15/2021] [Indexed: 11/20/2022] Open
Abstract
PURPOSE To investigate the trueness and marginal fit of computer-aided design-computer-aided manufactured (CAD-CAM) complete-arch implant-supported screw-retained fixed prosthesis (CAISFP) made of polyetheretherketone (PEEK), polyetherketoneketone (PEKK) and titanium (Ti) MATERIAL AND METHODS: A typodont model with four implants, their multiunit abutments (MUAs), and MUA scanbodies were digitized by using a laboratory scanner. The generated CAD was used to mill CAISFP frameworks in Ti, PEEK, or PEKK (each n = 10). The frameworks were digitized with an industrial light scanner to superimpose resulting standard tessellation language (STL) file with the CAD file. Deviations at five points at the abutment-framework interface of each of the four abutment sites (1:left first molar, 2:left canine, 3:right canine, 4:right first molar sites) were calculated (trueness). Marginal gaps were measured using the triple scan technique. A nonparametric repeated measures ANOVA by Brunner and Puri with factors being abutment location and material was performed to assess the mean deviations for trueness and mean marginal gaps, followed by Mann-Whitney or exact Wilcoxon Signed-Rank tests (alpha=.05). RESULTS Material type significantly affected the trueness (p<0.0001). PEEK had the lowest deviations (0.039 +/-0.01mm) followed by PEKK (0,049 +/-0.009mm), and Ti (0.074 +/-0.011mm). For marginal gaps, only abutment location's effect was significant (p = 0.003). Within PEKK, gaps at abutment 4 were significantly larger, compared with abutments 2 (p = 0.04) and 3 (p = 0.02). CONCLUSIONS The trueness of PEEK, PEKK, and Ti frameworks was different after milled. PEEK had the highest trueness. However, the marginal fit of the frameworks was similar and smaller than 90 µm in average. CLINICAL RELEVANCE PEEK, PEKK, and Ti complete-arch frameworks had clinically acceptable gaps and may therefore be recommended when their fit is considered. Higher trueness after milling did not result in better marginal fit.
Collapse
|
28
|
Donmez MB, Diken Turksayar AA, Olcay EO, Sahmali SM. Fracture Resistance of Single-Unit Implant-Supported Crowns: Effects of Prosthetic Design and Restorative Material. J Prosthodont 2021; 31:348-355. [PMID: 34383979 DOI: 10.1111/jopr.13415] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/10/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To evaluate the fracture resistance and fracture patterns of single implant-supported crowns with different prosthetic designs and materials. MATERIALS AND METHODS One hundred and forty-four identical crowns were fabricated from zirconia-reinforced lithium silicate (ZLS), leucite-based (LGC), and lithium disilicate (LDS) glass-ceramics, reinforced composite (RC), translucent zirconia (ZR), and ceramic-reinforced polyetheretherketone (P). These crowns were divided into 3 subgroups according to restoration design: cementable crowns on a prefabricated titanium abutment, cement-retained crown on a zirconia-titanium base abutment, and screw-cement crown (n = 8). After adhesive cementation, restorations were subjected to thermal-cycling and loaded until fracture. The fracture patterns were evaluated under a stereomicroscope. Statistical analysis was performed by using 2-way ANOVA/Bonferroni multiple comparison post hoc test (α = 0.05). RESULTS For each prosthetic design, ZR presented the highest fracture resistance (p ≤ 0.005). Other than the differences with ZLS and RC for screw-cement crowns (p > 0.05) and RC for crowns on zirconia-titanium base abutments (p > 0.05), LGC showed the lowest fracture resistance. P endured higher loads than LDS (p < 0.001), except for the crowns on zirconia-titanium base abutments (p > 0.05). Cementable crowns presented the highest fracture resistance (p < 0.001), other than LGC and LDS. The differences between LGC crowns (p > 0.05) or LDS crowns on prefabricated titanium and zirconia-titanium abutments were nonsignificant (p = 0.133). Fragmented crown fracture was predominant in most of the restorations. Screw and abutment fractures were observed in ZR screw-cement crowns, and all P crowns were separated from the abutments. CONCLUSIONS Restorative material and restoration design affect the fracture resistance and fracture pattern of implant-supported single-unit restorations. Clinicians may restore single-unit implants in premolar sites with the materials and prosthetic designs tested in the present study.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Biruni University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | | | - Emin Orkun Olcay
- Biruni University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | - Sevil Meral Sahmali
- Biruni University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| |
Collapse
|
29
|
Blanch-Martínez N, Arias-Herrera S, Martínez-González A. Behavior of polyether-ether-ketone (PEEK) in prostheses on dental implants. A review. J Clin Exp Dent 2021; 13:e520-e526. [PMID: 33981401 PMCID: PMC8106930 DOI: 10.4317/jced.58102] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Accepted: 12/20/2020] [Indexed: 11/20/2022] Open
Abstract
Background The development of new and innovative materials such as high performance polymers (PEEK) opens a wide therapeutic range in implant prostheses. They are presented as alternative materials to metal and zirconium alloys in the manufacture of structures and attachments for implant prostheses and fixed and removable dental substitutes. The objective of this review is to know the characteristics of this material and thus assess its advantages and disadvantages in its possible applications in prostheses on dental implants.
Material and Methods A bibliographic search was carried out through the PubMed and Scopus search engines, of articles published from 2007 to 2020, excluding all articles in which PEEK was used for tooth prostheses. The data on the sufficiency of the PEEK material were organized according to its chemical, physical and mechanical properties.
Results 148 articles were found in the databases using as keywords; Polyetheretherketone; PEEK; BioHPP; healing abutments; dental prostheses; dental prosthodontics; Full-arch rehabilitation; fixed implant prosthodontics; implant-retained prostheses; implant prostheses.
Conclusions It is concluded that PEEK offers greater lightness, good aesthetics, biocompatibility, and an elastic modulus more similar to bone than other materials commonly used in implant prostheses; however, it presents a higher risk of fracture and abrasion. More long-term clinical studies will be necessary to advise its use in implant prostheses. Key words:Polyetheretherketone, PEEK, BioHPP, healing abutments, dental prostheses, dental prosthodontics,Full-arch rehabilitation, fixed implant prosthodontics, implant-retained prostheses, implant prostheses.
Collapse
Affiliation(s)
- Natalia Blanch-Martínez
- Universidad Europea de Valencia. Faculty of Health Sciences. Department of Dentistry.,Clinical and Applied in Implant-Prosthetics (ICAI) Research Group, Universidad Europea de Valencia. Faculty of Health Sciences. Department of Dentistry
| | - Santiago Arias-Herrera
- Universidad Europea de Valencia. Faculty of Health Sciences. Department of Dentistry.,Clinical and Applied in Implant-Prosthetics (ICAI) Research Group, Universidad Europea de Valencia. Faculty of Health Sciences. Department of Dentistry
| | - Amparo Martínez-González
- Universidad Europea de Valencia. Faculty of Health Sciences. Department of Dentistry.,Clinical and Applied in Implant-Prosthetics (ICAI) Research Group, Universidad Europea de Valencia. Faculty of Health Sciences. Department of Dentistry
| |
Collapse
|
30
|
Pan Y, Tsoi JKH, Lam WYH, Pow EHN. Implant framework misfit: A systematic review on assessment methods and clinical complications. Clin Implant Dent Relat Res 2020; 23:244-258. [PMID: 33331058 DOI: 10.1111/cid.12968] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 11/25/2020] [Accepted: 11/26/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND The fit of implant-supported prostheses is of prime importance for the long-term success of implant therapy. PURPOSE This systematic review aimed to evaluate recent evidence on current techniques for assessing implant-framework misfit, its associated strain/stress, and whether these misfits are related to mechanical, biological, and clinical consequences. MATERIALS AND METHODS An electronic search for publications from January 2010 to October 2020 was performed using the Pubmed, Embase, Web of Science, and Cochrane Library databases with combined keywords on implant-framework misfit assessments and related clinical complications. Inclusion and exclusion criteria were applied. After full-text analyses, data extraction was implemented on current techniques of misfit assessment and the relationship between the misfit and the induced strain/stress. RESULTS A total of 3 in vivo and 92 in vitro studies were selected, including 47 studies on quantifying the degree of implant-framework misfit with dimensional techniques, 24 studies measuring misfit-induced strain/stress with modeling techniques, and 24 studies using both methods. The technical details, advantages, and limitations of each technique were illustrated. The correlation between the implant-framework misfit and the induced strain/stress has been revealed in vitro, while that with the biological complications and implant/prostheses failure was weak in clinical studies. CONCLUSIONS Dimensional and modeling techniques are available to measure the implant-framework misfit. The passivity of implant-supported fixed prostheses appeared related to the induced strain/stress, but not the clinical complications. Further studies combining three-dimensional (3D) assessments using dimensional and modeling techniques was needed.
Collapse
Affiliation(s)
- Yu Pan
- Faculty of Dentistry, The University of Hong Kong, Hong Kong special administrative region, China
| | - James K H Tsoi
- Faculty of Dentistry, The University of Hong Kong, Hong Kong special administrative region, China
| | - Walter Y H Lam
- Faculty of Dentistry, The University of Hong Kong, Hong Kong special administrative region, China
| | - Edmond H N Pow
- Faculty of Dentistry, The University of Hong Kong, Hong Kong special administrative region, China
| |
Collapse
|
31
|
Sarfaraz H, Rasheed MN, Shetty SK, Prabhu UM, Fernandes K, Mohandas S. Comparison of the Bond Strength of Composite Resin to Zirconia and Composite Resin to Polyether Ether Ketone: An In Vitro Study. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2020; 12:S504-S509. [PMID: 33149512 PMCID: PMC7595458 DOI: 10.4103/jpbs.jpbs_147_20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 03/02/2020] [Accepted: 03/09/2020] [Indexed: 11/22/2022] Open
Abstract
Aim: The aim of the study was to compare the shear bond strength of composite resin bonded to polyether ether ketone (PEEK) and zirconia, and also to evaluate the effect of thermocycling on the shear bond strength. Materials and Methods: A total of 22 zirconia (Group 1) and 22 PEEK (Group 2) specimens (disks of 10 mm in diameter and 10 mm in thickness) were machine milled using computer-aided design (CAD)/computer-aided manufacturing (CAM) from commercially available zirconia and PEEK. These specimens were air abraded with 110-μm aluminum oxide. Following which these two groups were subdivided into four groups, that is, Group 1A: 11 zirconia specimens before thermocycling, Group 1B: 11 zirconia specimens after thermocycling, Group 2A: 11 PEEK specimens before thermocycling, and Group 2B: 11 PEEK specimens after thermocycling. These four groups of specimens were embedded in an acrylic block, and bonding agent was applied over the upper surfaces of the disks of each of these specimens. Composite resin was then cured, and then Group 1B and group 2B were thermocycled under a standard temperature. The bond strength of the specimen was tested using universal testing machine. Result: The result showed that there was no significant difference in shear bond strength between the groups, although higher shear bond strength was observed in the PEEK group. Conclusion: Shear bond strength of PEEK is similar to zirconia. The results suggest that the pretreatment method and primers used were effective in improving the bonding of resin cements to zirconia ceramic and the bonding properties of the veneering resin to the PEEK surface.
Collapse
Affiliation(s)
- Hasan Sarfaraz
- Department of Prosthodontics, Yenepoya Dental College, Mangaluru, Karnataka, India
| | - Mohammed N Rasheed
- Department of Prosthodontics, Yenepoya Dental College, Mangaluru, Karnataka, India
| | - Sanath K Shetty
- Department of Prosthodontics, Yenepoya Dental College, Mangaluru, Karnataka, India
| | - Uma M Prabhu
- Department of Prosthodontics, Yenepoya Dental College, Mangaluru, Karnataka, India
| | - Kevin Fernandes
- Department of Prosthodontics, Yenepoya Dental College, Mangaluru, Karnataka, India
| | - Smrithi Mohandas
- Department of Prosthodontics, Yenepoya Dental College, Mangaluru, Karnataka, India
| |
Collapse
|
32
|
Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health 2020; 20:217. [PMID: 32741366 PMCID: PMC7398079 DOI: 10.1186/s12903-020-01202-7] [Citation(s) in RCA: 111] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/20/2020] [Indexed: 02/06/2023] Open
Abstract
Background Advanced computer-aided design and computer-aided manufacturing (CAD-CAM) technology led to the introduction of an increasing number of machinable materials suitable for dental prostheses. One of these materials is polyetheretherketone (PEEK), a high performance polymer recently used in dentistry with favorable physical, mechanical and chemical properties. The purpose of this study was to review the current published literature on the use of PEEK for the fabrication of dental prostheses with CAD-CAM techniques. Methods Electronic database searches were performed using the terms “PEEK”, “CAD-CAM”, “dental”, “dentistry” to identify studies related to the use of PEEK for the fabrication of CAD-CAM prostheses. The search period spanned from January 1990 through February 2020. Both in vivo and in vitro studies in English were eligible. Review articles and the references of the included publications were searched to identify relevant articles. Results A great number of in vitro studies are available in the current literature pointing out the noticeable properties of PEEK. The use of PEEK has been recommended for a wide range of CAD-CAM fabricated fixed and removable dental prostheses. PEEK was additionally recommended for occlusal splints, intra-radicular posts, implant abutments, customized healing abutments and provisional restorations. However, only a few clinical studies were identified. Conclusions PEEK could be considered as a viable alternative for CAD-CAM fixed and removable dental prostheses to well-established dental materials. Due to the scarcity of clinical data, clinical trials are needed to assess the long-term performance of PEEK prostheses.
Collapse
Affiliation(s)
- Ioannis Papathanasiou
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| | - Phophi Kamposiora
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece.
| | - George Papavasiliou
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| | - Marco Ferrari
- Department of Prosthodontics and Dental Materials, School of Dental Medicine, University of Siena, Siena, Italy
| |
Collapse
|