1
|
Mirahmadi H, Rahmati-Balaghaleh M, Afzalaghaee M, Zarean M, Shamsian SA, Mehravaran A, Raissi V, Etemadi S. Detection of malaria using blood smear by light microscopy, RDT and nested-PCR for suspected patients in south-eastern Iran. GENE REPORTS 2021. [DOI: 10.1016/j.genrep.2021.101339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
2
|
Sun BR, Zhou AG, Li X, Yu HZ. Development and Application of Mobile Apps for Molecular Sensing: A Review. ACS Sens 2021; 6:1731-1744. [PMID: 33955727 DOI: 10.1021/acssensors.1c00512] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Modern smartphone-based sensing devices are generally standalone detection platforms that can transduce signals (via the built-in USB port, audio jack, or camera), perform analysis through mobile applications (apps), and display results on the screen/user interface. The advancement toward this ultimate form of on-site chemical analysis and point-of-care diagnosis is tied closely with the evolution of mobile technology. Previous reviews in the field mainly focused on the physical platforms while overlooking the role of mobile apps in such devices. There exist three general stages throughout the development: (1) early generation telemedicine, (2) mobile phone-assisted clinical diagnosis (without apps), and (3) mobile app-based sensing devices for various analytes. This review presents the key breakthroughs during each stage, recent development, remaining challenges, and future perspectives of the field. Representative examples, spanning from the pioneering point-of-care testing to the latest devices with integrated mobile apps, are classified by their sensing mechanisms. The review also discusses the scarcity of open-source apps dedicated to molecular sensing. With the introduction of more open-source and commercial apps, the mobile app-based detection system is anticipated to dominate point-of-care diagnosis and on-site molecular sensing in our opinion.
Collapse
Affiliation(s)
- Brigitta R. Sun
- Department of Chemistry, Simon Fraser University, Burnaby, British Columbia V5A 1S6, Canada
| | - Alvin G. Zhou
- Department of Chemistry, Simon Fraser University, Burnaby, British Columbia V5A 1S6, Canada
| | - Xiaochun Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi 030024, P.R. China
| | - Hua-Zhong Yu
- Department of Chemistry, Simon Fraser University, Burnaby, British Columbia V5A 1S6, Canada
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, Shanxi 030024, P.R. China
| |
Collapse
|
3
|
Abstract
BACKGROUND Plasmodium vivax (P vivax) is a focus of malaria elimination. It is important because P vivax and Plasmodium falciparum infection are co-endemic in some areas. There are asymptomatic carriers of P vivax, and the treatment for P vivax and Plasmodium ovale malaria differs from that used in other types of malaria. Rapid diagnostic tests (RDTs) will help distinguish P vivax from other malaria species to help treatment and elimination. There are RDTs available that detect P vivax parasitaemia through the detection of P vivax-specific lactate dehydrogenase (LDH) antigens. OBJECTIVES To assess the diagnostic accuracy of RDTs for detecting P vivax malaria infection in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria; and to identify which types and brands of commercial tests best detect P vivax malaria. SEARCH METHODS We undertook a comprehensive search of the following databases up to 30 July 2019: Cochrane Infectious Diseases Group Specialized Register; Central Register of Controlled Trials (CENTRAL), published in the Cochrane Library; MEDLINE (PubMed); Embase (OVID); Science Citation Index Expanded (SCI-EXPANDED) and Conference Proceedings Citation Index-Science (CPCI-S), both in the Web of Science. SELECTION CRITERIA Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction (PCR)) in blood samples from patients attending ambulatory health facilities with symptoms suggestive of malaria in P vivax-endemic areas. DATA COLLECTION AND ANALYSIS For each included study, two review authors independently extracted data using a pre-piloted data extraction form. The methodological quality of the studies were assessed using a tailored Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. We grouped studies according to commercial brand of the RDT and performed meta-analysis when appropriate. The results given by the index tests were based on the antibody affinity (referred to as the strength of the bond between an antibody and an antigen) and avidity (referred to as the strength of the overall bond between a multivalent antibody and multiple antigens). All analyses were stratified by the type of reference standard. The bivariate model was used to estimate the pooled sensitivity and specificity with 95% confidence intervals (CIs), this model was simplified when studies were few. We assessed the certainty of the evidence using the GRADE approach. MAIN RESULTS We included 10 studies that assessed the accuracy of six different RDT brands (CareStart Malaria Pf/Pv Combo test, Falcivax Device Rapid test, Immuno-Rapid Malaria Pf/Pv test, SD Bioline Malaria Ag Pf/Pv test, OnSite Pf/Pv test and Test Malaria Pf/Pv rapid test) for detecting P vivax malaria. One study directly compared the accuracy of two RDT brands. Of the 10 studies, six used microscopy, one used PCR, two used both microscopy and PCR separately and one used microscopy corrected by PCR as the reference standard. Four of the studies were conducted in Ethiopia, two in India, and one each in Bangladesh, Brazil, Colombia and Sudan. The studies often did not report how patients were selected. In the patient selection domain, we judged the risk of bias as unclear for nine studies. We judged all studies to be of unclear applicability concern. In the index test domain, we judged most studies to be at low risk of bias, but we judged nine studies to be of unclear applicability concern. There was poor reporting on lot testing, how the RDTs were stored, and background parasitaemia density (a key variable determining diagnostic accuracy of RDTs). Only half of the included studies were judged to be at low risk of bias in the reference standard domain, Studies often did not report whether the results of the reference standard could classify the target condition or whether investigators knew the results of the RDT when interpreting the results of the reference standard. All 10 studies were judged to be at low risk of bias in the flow and timing domain. Only two brands were evaluated by more than one study. Four studies evaluated the CareStart Malaria Pf/Pv Combo test against microscopy and two studies evaluated the Falcivax Device Rapid test against microscopy. The pooled sensitivity and specificity were 99% (95% CI 94% to 100%; 251 patients, moderate-certainty evidence) and 99% (95% CI 99% to 100%; 2147 patients, moderate-certainty evidence) for CareStart Malaria Pf/Pv Combo test. For a prevalence of 20%, about 206 people will have a positive CareStart Malaria Pf/Pv Combo test result and the remaining 794 people will have a negative result. Of the 206 people with positive results, eight will be incorrect (false positives), and of the 794 people with a negative result, two would be incorrect (false negative). For the Falcivax Device Rapid test, the pooled sensitivity was 77% (95% CI: 53% to 91%, 89 patients, low-certainty evidence) and the pooled specificity was 99% (95% CI: 98% to 100%, 621 patients, moderate-certainty evidence), respectively. For a prevalence of 20%, about 162 people will have a positive Falcivax Device Rapid test result and the remaining 838 people will have a negative result. Of the 162 people with positive results, eight will be incorrect (false positives), and of the 838 people with a negative result, 46 would be incorrect (false negative). AUTHORS' CONCLUSIONS The CareStart Malaria Pf/Pv Combo test was found to be highly sensitive and specific in comparison to microscopy for detecting P vivax in ambulatory healthcare in endemic settings, with moderate-certainty evidence. The number of studies included in this review was limited to 10 studies and we were able to estimate the accuracy of 2 out of 6 RDT brands included, the CareStart Malaria Pf/Pv Combo test and the Falcivax Device Rapid test. Thus, the differences in sensitivity and specificity between all the RDT brands could not be assessed. More high-quality studies in endemic field settings are needed to assess and compare the accuracy of RDTs designed to detect P vivax.
Collapse
Affiliation(s)
- Ridhi Agarwal
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Leslie Choi
- Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| | - Samuel Johnson
- Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| | - Yemisi Takwoingi
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| |
Collapse
|
4
|
Yerlikaya S, Campillo A, Gonzalez IJ. A Systematic Review: Performance of Rapid Diagnostic Tests for the Detection of Plasmodium knowlesi, Plasmodium malariae, and Plasmodium ovale Monoinfections in Human Blood. J Infect Dis 2019; 218:265-276. [PMID: 29554284 PMCID: PMC6009649 DOI: 10.1093/infdis/jiy150] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 03/15/2018] [Indexed: 11/13/2022] Open
Abstract
Background Despite the increased use and worldwide distribution of malaria rapid diagnostic tests (RDTs) that distinguish between Plasmodium falciparum and non-falciparum species, little is known about their performance detecting Plasmodium knowlesi (Pk), Plasmodium malariae (Pm), and Plasmodium ovale (Po). This review seeks to analyze the results of published studies evaluating the diagnostic accuracy of malaria RDTs in detecting Pk, Pm, and Po monoinfections. Methods MEDLINE, EMBASE, Web of Science, and CENTRAL databases were systematically searched to identify studies that reported the performance of RDTs in detecting Pk, Pm, and Po monoinfections. Results Among 40 studies included in the review, 3 reported on Pk, 8 on Pm, 5 on Po, 1 on Pk and Pm, and 23 on Pm and Po infections. In the meta-analysis, estimates of sensitivities of RDTs in detecting Pk infections ranged 2%-48%. Test performances for Pm and Po infections were less accurate and highly heterogeneous, mainly because of the small number of samples tested. Conclusions Limited data available suggest that malaria RDTs show suboptimal performance for detecting Pk, Pm, and Po infections. New improved RDTs and appropriately designed cross-sectional studies to demonstrate the usefulness of RDTs in the detection of neglected Plasmodium species are urgently needed.
Collapse
Affiliation(s)
- Seda Yerlikaya
- Foundation for Innovative New Diagnostics (FIND), Geneva, Switzerland
| | - Ana Campillo
- Foundation for Innovative New Diagnostics (FIND), Geneva, Switzerland
| | - Iveth J Gonzalez
- Foundation for Innovative New Diagnostics (FIND), Geneva, Switzerland
| |
Collapse
|
5
|
Imai K, Tarumoto N, Misawa K, Runtuwene LR, Sakai J, Hayashida K, Eshita Y, Maeda R, Tuda J, Murakami T, Maesaki S, Suzuki Y, Yamagishi J, Maeda T. A novel diagnostic method for malaria using loop-mediated isothermal amplification (LAMP) and MinION™ nanopore sequencer. BMC Infect Dis 2017; 17:621. [PMID: 28903726 PMCID: PMC5598014 DOI: 10.1186/s12879-017-2718-9] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Accepted: 09/06/2017] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND A simple and accurate molecular diagnostic method for malaria is urgently needed due to the limitations of conventional microscopic examination. In this study, we demonstrate a new diagnostic procedure for human malaria using loop mediated isothermal amplification (LAMP) and the MinION™ nanopore sequencer. METHODS We generated specific LAMP primers targeting the 18S-rRNA gene of all five human Plasmodium species including two P. ovale subspecies (P. falciparum, P. vivax, P. ovale wallikeri, P. ovale curtisi, P. knowlesi and P. malariae) and examined human blood samples collected from 63 malaria patients in Indonesia. Additionally, we performed amplicon sequencing of our LAMP products using MinION™ nanopore sequencer to identify each Plasmodium species. RESULTS Our LAMP method allowed amplification of all targeted 18S-rRNA genes of the reference plasmids with detection limits of 10-100 copies per reaction. Among the 63 clinical samples, 54 and 55 samples were positive by nested PCR and our LAMP method, respectively. Identification of the Plasmodium species by LAMP amplicon sequencing analysis using the MinION™ was consistent with the reference plasmid sequences and the results of nested PCR. CONCLUSIONS Our diagnostic method combined with LAMP and MinION™ could become a simple and accurate tool for the identification of human Plasmodium species, even in resource-limited situations.
Collapse
Affiliation(s)
- Kazuo Imai
- Division of Infectious Diseases and Pulmonary Medicine, Department of Internal Medicine, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama, 359-8513, Japan
| | - Norihito Tarumoto
- Department of Infectious Disease and Infection Control, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan.,Center for Clinical Infectious Diseases and Research, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan
| | - Kazuhisa Misawa
- Division of Infectious Diseases and Pulmonary Medicine, Department of Internal Medicine, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama, 359-8513, Japan
| | - Lucky Ronald Runtuwene
- Department of Computational Biology and Medical Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba, 277-8562, Japan
| | - Jun Sakai
- Department of Infectious Disease and Infection Control, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan.,Center for Clinical Infectious Diseases and Research, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan
| | - Kyoko Hayashida
- Research Center for Zoonosis Control, Hokkaido University, North 20, West 10 Kita-ku, Sapporo, Hokkaido, 001-0020, Japan
| | - Yuki Eshita
- Research Center for Zoonosis Control, Hokkaido University, North 20, West 10 Kita-ku, Sapporo, Hokkaido, 001-0020, Japan.,Faculty of Medicine, Oita University, 1-1 Hasama-machi, Yufu, Oita, 879-5593, Japan.,Department of Medical Entomology, Faculty of Tropical Medicine, Mahidol University, 420/6 Ratchawithi Road, Thung Phaya, Ratchathewi, Bangkok, 10400, Thailand.,Research Institute for Microbial Diseases, Osaka University, 3-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Ryuichiro Maeda
- Division of Biomedical Sciences, Department of Basic Veterinary Medicine, Obihiro University of Agriculture and Veterinary Medicine, 2-11 Inada-cho, Obihiro, Hokkaido, 080-8555, Japan
| | - Josef Tuda
- Department of Parasitology, Faculty of Medicine, Sam Ratulangi University, Kampus Unsrat, Manado, Bahu, 95115, Indonesia
| | - Takashi Murakami
- Center for Clinical Infectious Diseases and Research, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan.,Department of Microbiology, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan
| | - Shigefumi Maesaki
- Department of Infectious Disease and Infection Control, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan.,Center for Clinical Infectious Diseases and Research, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan
| | - Yutaka Suzuki
- Department of Computational Biology and Medical Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba, 277-8562, Japan
| | - Junya Yamagishi
- Research Center for Zoonosis Control, Hokkaido University, North 20, West 10 Kita-ku, Sapporo, Hokkaido, 001-0020, Japan.,Global Station for Zoonosis Control, GI-CoRE, Hokkaido University, North 20, West 10 Kita-ku, Sapporo, Hokkaido, 001-0020, Japan
| | - Takuya Maeda
- Center for Clinical Infectious Diseases and Research, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan. .,Department of Microbiology, Saitama Medical University, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan.
| |
Collapse
|
6
|
Chua KH, Lee PC, Chai HC. Development of insulated isothermal PCR for rapid on-site malaria detection. Malar J 2016; 15:134. [PMID: 26931146 PMCID: PMC4773996 DOI: 10.1186/s12936-016-1183-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2015] [Accepted: 02/19/2016] [Indexed: 01/03/2023] Open
Abstract
BACKGROUND Detection of Plasmodium spp. is sometimes inconvenient especially in rural areas that are distant from a laboratory. In this study a portable diagnostic test of Plasmodium spp. was developed using insulated isothermal polymerase chain reaction (iiPCR) as an alternative approach to improve this situation. METHODS A pair of universal primers and probe were designed to amplify and detect gene encoding 18S small sub-unit rRNA of Plasmodium spp using iiPCR method in a portable device, POCKIT™. The efficiency and detection limit of the assay were evaluated using quantitative real-time polymerase chain reaction (qPCR) approach before being subjected to testing in POCKIT™. Detection results of POCKIT™ were displayed as '+', '-' or '?' based on the fluorescence ratio after/before reaction. A total of 55 and 35 samples from malaria patients and healthy subjects, respectively, were screened to evaluate the feasibility of this newly designed iiPCR assay. RESULTS The iiPCR assay allowed the detection of various species of Plasmodium, including those infecting humans (Plasmodium falciparum, P. vivax, P. knowlesi, P. malariae, P. ovale), monkeys, birds, and rodents. Efficiency of the assay achieved 96.9 % while the lower detection limit was ≥100 copies of plasmodial DNA. Specificity of the assay was assured as it could not detect human, bacterial and other parasitic DNA. Among the 55 clinical samples tested, 47 (85.4 %) of them were detected as positive by POCKIT™. Four (7.3 %) samples with fluorescence ratio after/before reaction of <1.2 were reported as negative while another four (7.3 %) were ambiguously detected as they had fluorescence ratios between 1.2 and 1.3. The fluorescence ratio was not found to be associated with the copy number of plasmodial DNA. This approach can only be considered as a qualitative method. CONCLUSIONS The portable iiPCR system may serve as an alternative approach for preliminary screening of malaria in endemic rural areas. The system may also be useful for detecting animal malaria in the field. Although it is not as quantitative as qPCR method, it is comparatively fast and easy to handle. It is believed that the POCKIT-iiPCR assay is able to achieve 100 % sensitivity if increased amount of DNA from each sample is used. The iiPCR assay can also be upgraded in future to detect multiple Plasmodium spp. at the same time by designing the specific primers and probes.
Collapse
Affiliation(s)
- Kek Heng Chua
- Department of Biomedical Science, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia.
| | - Ping Chin Lee
- School of Science and Technology, Universiti Malaysia Sabah, 88400, Kota Kinabalu, Sabah, Malaysia.
| | - Hwa Chia Chai
- Department of Biomedical Science, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia.
| |
Collapse
|
7
|
Abba K, Kirkham AJ, Olliaro PL, Deeks JJ, Donegan S, Garner P, Takwoingi Y. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries. Cochrane Database Syst Rev 2014; 2014:CD011431. [PMID: 25519857 PMCID: PMC4453861 DOI: 10.1002/14651858.cd011431] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
BACKGROUND In settings where both Plasmodium vivax and Plasmodium falciparum infection cause malaria, rapid diagnostic tests (RDTs) need to distinguish which species is causing the patients' symptoms, as different treatments are required. Older RDTs incorporated two test lines to distinguish malaria due to P. falciparum, from malaria due to any other Plasmodium species (non-falciparum). These RDTs can be classified according to which antibodies they use: Type 2 RDTs use HRP-2 (for P. falciparum) and aldolase (all species); Type 3 RDTs use HRP-2 (for P. falciparum) and pLDH (all species); Type 4 use pLDH (fromP. falciparum) and pLDH (all species).More recently, RDTs have been developed to distinguish P. vivax parasitaemia by utilizing a pLDH antibody specific to P. vivax. OBJECTIVES To assess the diagnostic accuracy of RDTs for detecting non-falciparum or P. vivax parasitaemia in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria, and to identify which types and brands of commercial test best detect non-falciparum and P. vivax malaria. SEARCH METHODS We undertook a comprehensive search of the following databases up to 31 December 2013: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; and IndMED. SELECTION CRITERIA Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in non-falciparum endemic areas. DATA COLLECTION AND ANALYSIS For each study, two review authors independently extracted a standard set of data using a tailored data extraction form. We grouped comparisons by type of RDT (defined by the combinations of antibodies used), and combined in meta-analysis where appropriate. Average sensitivities and specificities are presented alongside 95% confidence intervals (95% CI). MAIN RESULTS We included 47 studies enrolling 22,862 participants. Patient characteristics, sampling methods and reference standard methods were poorly reported in most studies. RDTs detecting 'non-falciparum' parasitaemiaEleven studies evaluated Type 2 tests compared with microscopy, 25 evaluated Type 3 tests, and 11 evaluated Type 4 tests. In meta-analyses, average sensitivities and specificities were 78% (95% CI 73% to 82%) and 99% (95% CI 97% to 99%) for Type 2 tests, 78% (95% CI 69% to 84%) and 99% (95% CI 98% to 99%) for Type 3 tests, and 89% (95% CI 79% to 95%) and 98% (95% CI 97% to 99%) for Type 4 tests, respectively. Type 4 tests were more sensitive than both Type 2 (P = 0.01) and Type 3 tests (P = 0.03).Five studies compared Type 3 tests with PCR; in meta-analysis, the average sensitivity and specificity were 81% (95% CI 72% to 88%) and 99% (95% CI 97% to 99%) respectively. RDTs detecting P.vivax parasitaemiaEight studies compared pLDH tests to microscopy; the average sensitivity and specificity were 95% (95% CI 86% to 99%) and 99% (95% CI 99% to 100%), respectively. AUTHORS' CONCLUSIONS RDTs designed to detect P. vivax specifically, whether alone or as part of a mixed infection, appear to be more accurate than older tests designed to distinguish P. falciparum malaria from non-falciparum malaria. Compared to microscopy, these tests fail to detect around 5% ofP. vivax cases. This Cochrane Review, in combination with other published information about in vitro test performance and stability in the field, can assist policy-makers to choose between the available RDTs.
Collapse
Affiliation(s)
- Katharine Abba
- Department of Clinical Sciences, Liverpool School of Tropical Medicine, Pembroke Place, Liverpool, UK.
| | | | | | | | | | | | | |
Collapse
|
8
|
Djallé D, Gody JC, Moyen JM, Tekpa G, Ipero J, Madji N, Breurec S, Manirakiza A. Performance of Paracheck™-Pf, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan for diagnosis of falciparum malaria in the Central African Republic. BMC Infect Dis 2014; 14:109. [PMID: 24568311 PMCID: PMC3938899 DOI: 10.1186/1471-2334-14-109] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Accepted: 02/20/2014] [Indexed: 11/17/2022] Open
Abstract
Background Rapid diagnostic tests (RDTs) are the current complement to microscopy for ensuring prompt malaria treatment. We determined the performance of three candidate RDTs (Paracheck™-Pf, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan) for rapid diagnosis of malaria in the Central African Republic. Methods Blood samples from consecutive febrile patients who attended for laboratory analysis of malaria at the three main health centres of Bangui were screened by microscopy and the RDTs. Two reference standards were used to assess the performance of the RDTs: microscopy and, a combination of microscopy plus nested PCR for slides reported as negative, on the assumption that negative results by microscopy were due to sub-patent parasitaemia. Results We analysed 436 samples. Using the combined reference standard of microscopy + PCR, the sensitivity of Paracheck™-Pf was 85.7% (95% CI, 80.8–89.8%), that of SD Bioline Ag-Pf was 85.4% (95% CI, 80.5–90.7%), and that of SD Bioline Ag-Pf/pan was 88.2% (95% CI, 83.2–92.0%). The tests performed less well in cases of low parasitaemia; however, the sensitivity was > 95% at > 500 parasites/μl. Conclusions Overall, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan performed slightly better than Paracheck™-Pf. Use of RDTs with reinforced microscopy practice and laboratory quality assurance should improve malaria treatment in the Central African Republic.
Collapse
|
9
|
Siala E, Foudhaili H, Doggi A, Gamara D, Ben Alaya N, Ben Abdallah R, Tiouiri H, Aoun K, Bouratbine A. [Evaluation and contribution of OptiMAL-IT® test for the diagnosis of imported malaria in Tunisia]. BULLETIN DE LA SOCIETE DE PATHOLOGIE EXOTIQUE (1990) 2013; 106:233-238. [PMID: 24136659 DOI: 10.1007/s13149-013-0311-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Accepted: 09/17/2013] [Indexed: 06/02/2023]
Abstract
The rapid test OptiMAL-IT® was evaluated in the diagnosis and the screening of imported malaria in Tunisia in comparison with microscopic techniques. This prospective study focused on 500 individuals recruited from September 2010 to September 2012 in laboratory of Parasitology of Pasteur Institute of Tunis. They include 192 patients with clinical manifestations suggestive of malaria and 308 students originating from endemic areas. Microscopy of thick-and-thin blood smears and OptiMAL-IT® test were systematically performed on blood samples of all participants. Sixty individuals revealed infected by Plasmodium (12%). Positivity rates were respectively 20.3% in patients (44 cases) and 5.2% among asymptomatic students (16 cases) (p<0.01). The sensitivity and specificity of the OptiMAL-IT® test were respectively 88.6% and 100%. The concordance kappa was 0.92. The sensitivity and specificity during the screening of asymptomatic subjects were respectively 68.8% and 98.3% with a concordance of 0.67.
Collapse
Affiliation(s)
- E Siala
- Laboratoire de parasitologie mycologie, Institut Pasteur, 1002, Tunis, Tunisie,
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Chou M, Kim S, Khim N, Chy S, Sum S, Dourng D, Canier L, Nguon C, Ménard D. Performance of "VIKIA Malaria Ag Pf/Pan" (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections. Malar J 2012; 11:295. [PMID: 22920654 PMCID: PMC3478208 DOI: 10.1186/1475-2875-11-295] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2012] [Accepted: 08/15/2012] [Indexed: 11/17/2022] Open
Abstract
Background Recently, IMACCESS® developed a new malaria test (VIKIA Malaria Ag Pf/Pan™), based on the detection of falciparum malaria (HRP-2) and non-falciparum malaria (aldolase). Methods The performance of this new malaria rapid diagnostic test (RDT) was assessed using 1,000 febrile patients seeking malaria treatment in four health centres in Cambodia from August to December 2011. The results of the VIKIA Malaria Ag Pf/Pan were compared with those obtained by microscopy, the CareStart Malaria™ RDT (AccessBio®) which is currently used in Cambodia, and real-time PCR (as “gold standard”). Results The best performances of the VIKIA Malaria Ag Pf/Pan™ test for detection of both Plasmodium falciparum and non-P. falciparum were with 20–30 min reading times (sensitivity of 93.4% for P. falciparum and 82.8% for non-P. falciparum and specificity of 98.6% for P. falciparum and 98.9% for non-P. falciparum) and were similar to those for the CareStart Malaria™ test. Conclusions This new RDT performs similarly well as other commercially available tests (especially the CareStart Malaria™ test, used as comparator), and conforms to the World Health Organization’s recommendations for RDT performance. It is a good alternative tool for the diagnosis of malaria in endemic areas.
Collapse
Affiliation(s)
- Monidarin Chou
- Faculty of Pharmacy, Université des Sciences de la Santé, Phnom Penh, Cambodia
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Mudanyali O, Dimitrov S, Sikora U, Padmanabhan S, Navruz I, Ozcan A. Integrated rapid-diagnostic-test reader platform on a cellphone. LAB ON A CHIP 2012; 12:2678-86. [PMID: 22596243 PMCID: PMC3390446 DOI: 10.1039/c2lc40235a] [Citation(s) in RCA: 267] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We demonstrate a cellphone-based rapid-diagnostic-test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 g, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting diode (LED)-based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 s per image) through a smart application running on the cellphone for validation of the RDT, as well as for automated reading of its diagnostic result. The same smart application then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data), to a central server, which presents the diagnostic results on a world map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) and HIV RDTs by installing it on both Android-based smartphones and an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist healthcare professionals and policymakers to track emerging epidemics worldwide and help epidemic preparedness.
Collapse
Affiliation(s)
- Onur Mudanyali
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Stoyan Dimitrov
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Uzair Sikora
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Swati Padmanabhan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Isa Navruz
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| |
Collapse
|
12
|
Comparative Study on the Effects of Chloroquine and Artesunate on Histopathological Damages Caused by Plasmodium berghei in Four Vital Organs of Infected Albino Mice. Malar Res Treat 2012; 2012:960758. [PMID: 22792509 PMCID: PMC3388589 DOI: 10.1155/2012/960758] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2011] [Revised: 02/23/2012] [Accepted: 04/30/2012] [Indexed: 11/18/2022] Open
Abstract
The aim of the present study was to investigate the positive influence of chloroquine and artesunate on the pathological damages caused by Plasmodium berghei on vital organs of mice in an established infection. Healthy adult albino mice with average weight of 25 g were used for the study. Treated group was administered orally with 100 mg/kg of chloroquine and artesunate, respectively. Control animals were given water for the same period. Histological examination of the liver, spleen, lungs, and kidney revealed absence of accumulation of iron (haemosiderosis) in the liver, thickened alveolar wall, and interstitial mononuclear cells infiltration in the lungs of the artesunate group, while absence of emphysema in the lungs and megakaryoblast hyperplasia in the spleen was observed in the chloroquine group. Lymphoid hypoplasia in the chloroquine group and megakayoblast hyperplasia in the artesunate group were observed but not in the control group. Thus, the use of these drugs especially under the practice of self-medication should be prohibited in lands where they are still in use as antimalaria medicine.
Collapse
|
13
|
Abba K, Deeks JJ, Olliaro PL, Naing C, Jackson SM, Takwoingi Y, Donegan S, Garner P. Rapid diagnostic tests for diagnosing uncomplicated P. falciparum malaria in endemic countries. Cochrane Database Syst Rev 2011; 2011:CD008122. [PMID: 21735422 PMCID: PMC6532563 DOI: 10.1002/14651858.cd008122.pub2] [Citation(s) in RCA: 128] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND Rapid diagnostic tests (RDTs) for Plasmodium falciparum malaria use antibodies to detect either HRP-2 antigen or pLDH antigen, and can improve access to diagnostics in developing countries. OBJECTIVES To assess the diagnostic accuracy of RDTs for detecting P. falciparum parasitaemia in persons living in endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria by type and brand. SEARCH STRATEGY We undertook a comprehensive search of the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; IndMED; to January 14, 2010. SELECTION CRITERIA Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in P. falciparum endemic areas. DATA COLLECTION AND ANALYSIS For each study, a standard set of data was extracted independently by two authors, using a tailored data extraction form. Comparisons were grouped hierarchically by target antigen, and type and brand of RDT, and combined in meta-analysis where appropriate. MAIN RESULTS We identified 74 unique studies as eligible for this review and categorized them according to the antigens they detected. Types 1 to 3 include HRP-2 (from P. falciparum) either by itself or with other antigens. Types 4 and 5 included pLDH (from P. falciparum) either by itself or with other antigens. In comparisons with microscopy, we identified 71 evaluations of Type 1 tests, eight evaluations of Type 2 tests and five evaluations of Type 3 tests. In meta-analyses, average sensitivities and specificities (95% CI) were 94.8% (93.1% to 96.1%) and 95.2% (93.2% to 96.7%) for Type 1 tests, 96.0% (94.0% to 97.3%) and 95.3% (87.3% to 98.3%) for Type 2 tests, and 99.5% (71.0% to 100.0%) and 90.6% (80.5% to 95.7%) for Type 3 tests, respectively. Overall for HRP-2, the meta-analytical average sensitivity and specificity (95% CI) were 95.0% (93.5% to 96.2%) and 95.2% (93.4% to 99.4%), respectively. For pLDH antibody-based RDTs verified with microscopy, we identified 17 evaluations of Type 4 RDTs and three evaluations of Type 5 RDTs. In meta-analyses, average sensitivity for Type 4 tests was 91.5% (84.7% to 95.3%) and average specificity was 98.7% (96.9% to 99.5%). For Type 5 tests, average sensitivity was 98.4% (95.1% to 99.5%) and average specificity was 97.5% (93.5% to 99.1%). Overall for pLDH, the meta-analytical average sensitivity and specificity (95% CI) were 93.2% (88.0% to 96.2%) and 98.5% (96.7% to 99.4%), respectively. For both categories of test, there was substantial heterogeneity in study results. Quality of the microscopy reference standard could only be assessed in 40% of studies due to inadequate reporting, but results did not seem to be influenced by the reporting quality.Overall, HRP-2 antibody-based tests (such as the Type 1 tests) tended to be more sensitive and were significantly less specific than pLDH-based tests (such as the Type 4 tests). If the point estimates for Type 1 and Type 4 tests are applied to a hypothetical cohort of 1000 patients where 30% of those presenting with symptoms have P. falciparum, Type 1 tests will miss 16 cases, and Type 4 tests will miss 26 cases. The number of people wrongly diagnosed with P. falciparum would be 34 with Type 1 tests, and nine with Type 4 tests. AUTHORS' CONCLUSIONS The sensitivity and specificity of all RDTs is such that they can replace or extend the access of diagnostic services for uncomplicated P. falciparum malaria. HRP-2 antibody types may be more sensitive but are less specific than pLDH antibody-based tests, but the differences are small. The HRP-2 antigen persists even after effective treatment and so is not useful for detecting treatment failures.
Collapse
Affiliation(s)
- Katharine Abba
- Liverpool School of Tropical MedicineInternational Health GroupPembroke PlaceLiverpoolMerseysideUKL3 5QA
| | - Jonathan J Deeks
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - Piero L Olliaro
- World Health OrganizationUNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR)1211 Geneva 27GenevaSwitzerland
| | - Cho‐Min Naing
- International Medical UniversityDivision of Community MedicineNo.126 Jalan 19/155BBukit JalilKuala LumpurMalaysia57000
| | - Sally M Jackson
- Liverpool School of Tropical MedicineInternational Health GroupPembroke PlaceLiverpoolMerseysideUKL3 5QA
| | - Yemisi Takwoingi
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - Sarah Donegan
- Liverpool School of Tropical MedicineInternational Health GroupPembroke PlaceLiverpoolMerseysideUKL3 5QA
| | - Paul Garner
- Liverpool School of Tropical MedicineInternational Health GroupPembroke PlaceLiverpoolMerseysideUKL3 5QA
| | | |
Collapse
|
14
|
Affiliation(s)
- Jane M. Carlton
- Department of Medical Parasitology, New York University School of Medicine, New York, New York, United States of America
| | - Barbara J. Sina
- Division of International Training and Research, Fogarty International Center, National Institutes of Health, Bethesda, Maryland, United States of America
- * E-mail:
| | - John H. Adams
- Department of Global Health, College of Public Health, University of South Florida, Tampa, Florida, United States of America
| |
Collapse
|
15
|
Oliveira MRFD, Gomes ADC, Toscano CM. QUADAS e STARD: avaliação da qualidade de estudos de acurácia de testes diagnósticos. Rev Saude Publica 2011; 45:416-22. [DOI: 10.1590/s0034-89102011000200021] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Accepted: 08/25/2010] [Indexed: 11/21/2022] Open
Abstract
OBJETIVO: Comparar duas abordagens baseadas em critérios do Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e do Standards for Reporting Studies of Diagnostic Accuracy (STARD) na avaliação de qualidade de estudos de validação do teste rápido OptiMal®, para diagnóstico de malária. MÉTODOS: Foi realizada busca de artigos de validação do teste rápido na base bibliográfica Medline acessada pelo PubMed, no ano de 2007. Treze artigos foram recuperados na busca. Foram combinados 12 critérios do QUADAS e três do STARD para comparação com os critérios do QUADAS isoladamente. Foi considerado que artigos de regular a boa qualidade atenderiam pelo menos 50% dos critérios do QUADAS. RESULTADOS: Dos 13 artigos recuperados, 12 cumpriram pelo menos 50% dos critérios do QUADAS, e apenas dois atenderam à combinação dos critérios. Considerando-se a combinação dos dois critérios (> 6 QUADAS e > 3STARD), dois estudos (15,4%) apresentaram boa qualidade metodológica. A seleção de artigos usando a combinação proposta variou de dois a oito artigos, dependendo do número de itens considerados como ponto de corte. CONCLUSÕES: A combinação do QUADAS com o STARD tem o potencial de conferir maior rigor nas avaliações da qualidade de artigos publicados sobre validação de testes diagnósticos em malária, por incorporar a checagem de informações relevantes não alcançáveis pelo uso do QUADAS isoladamente.
Collapse
|
16
|
Ashton RA, Kefyalew T, Tesfaye G, Counihan H, Yadeta D, Cundill B, Reithinger R, Kolaczinski JH. Performance of three multi-species rapid diagnostic tests for diagnosis of Plasmodium falciparum and Plasmodium vivax malaria in Oromia Regional State, Ethiopia. Malar J 2010; 9:297. [PMID: 20979601 PMCID: PMC2988036 DOI: 10.1186/1475-2875-9-297] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2010] [Accepted: 10/27/2010] [Indexed: 04/14/2024] Open
Abstract
Background Malaria transmission in Ethiopia is unstable and variable, caused by both Plasmodium falciparum and Plasmodium vivax. The Federal Ministry of Health (FMoH) is scaling up parasitological diagnosis of malaria at all levels of the health system; at peripheral health facilities this will be through use of rapid diagnostic tests (RDTs). The present study compared three RDT products to provide the FMoH with evidence to guide appropriate product selection. Methods Performance of three multi-species (pf-HRP2/pan-pLDH and pf-HRP2/aldolase) RDTs (CareStart®, ParaScreen® and ICT Combo®) was compared with 'gold standard' microscopy at three health centres in Jimma zone, Oromia Regional State. Ease of RDT use by health extension workers was assessed at community health posts. RDT heat stability was tested in a controlled laboratory setting according to WHO procedures. Results A total of 2,383 patients with suspected malaria were enrolled between May and July 2009, 23.2% of whom were found to be infected with Plasmodium parasites by microscopy. All three RDTs were equally sensitive in detecting P. falciparum or mixed infection: 85.6% (95% confidence interval 81.2-89.4). RDT specificity was similar for detection of P. falciparum or mixed infection at around 92%. For detecting P. vivax infection, all three RDTs had similar sensitivity in the range of 82.5 to 85.0%. CareStart had higher specificity in detecting P. vivax (97.2%) than both ParaScreen and ICT Combo (p < 0.001 and p = 0.05, respectively). Health extension workers preferred CareStart and ParaScreen to ICT Combo due to the clear labelling of bands on the cassette, while the 'lab in a pack' style of CareStart was the preferred design. ParaScreen and CareStart passed all heat stability testing, while ICT Combo did not perform as well. Conclusions CareStart appeared to be the most appropriate option for use at health posts in Ethiopia, considering the combination of quantitative performance, ease of use and heat stability. When new products become available, the choice of multi-species RDT for Ethiopia should be regularly re-evaluated, as it would be desirable to identify a test with higher sensitivity than the ones evaluated here.
Collapse
Affiliation(s)
- Ruth A Ashton
- Malaria Consortium - Ethiopia Office, Ethio-China Road, PO Box 100224, Addis Ababa, Ethiopia.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Andrade BB, Reis-Filho A, Barros AM, Souza-Neto SM, Nogueira LL, Fukutani KF, Camargo EP, Camargo LMA, Barral A, Duarte A, Barral-Netto M. Towards a precise test for malaria diagnosis in the Brazilian Amazon: comparison among field microscopy, a rapid diagnostic test, nested PCR, and a computational expert system based on artificial neural networks. Malar J 2010; 9:117. [PMID: 20459613 PMCID: PMC2883547 DOI: 10.1186/1475-2875-9-117] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2010] [Accepted: 05/06/2010] [Indexed: 11/10/2022] Open
Abstract
Background Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. Methods The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Results Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). Conclusions An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available.
Collapse
|
18
|
Gerstl S, Dunkley S, Mukhtar A, De Smet M, Baker S, Maikere J. Assessment of two malaria rapid diagnostic tests in children under five years of age, with follow-up of false-positive pLDH test results, in a hyperendemic falciparum malaria area, Sierra Leone. Malar J 2010; 9:28. [PMID: 20092620 PMCID: PMC2835716 DOI: 10.1186/1475-2875-9-28] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Accepted: 01/21/2010] [Indexed: 11/27/2022] Open
Abstract
Background Most malaria rapid diagnostic tests (RDTs) use HRP2 detection, including Paracheck-Pf®, but their utility is limited by persistent false positivity after treatment. PLDH-based tests become negative more quickly, but sensitivity has been reported below the recommended standard of 90%. A new pLDH test, CareStart™ three-line P.f/PAN-pLDH, claims better sensitivity with continued rapid conversion to negative. The study aims were to 1) compare sensitivity and specificity of CareStart™ to Paracheck-Pf® to diagnose falciparum malaria in children under five years of age, 2) assess how quickly false-positive CareStart™ tests become negative and 3) evaluate ease of use and inter-reader agreement of both tests. Methods Participants were included if they were aged between two and 59 months, presenting to a Médecins Sans Frontières community health centre in eastern Sierra Leone with suspected malaria defined as fever (axillary temperature > 37.5°C) and/or history of fever in the previous 72 hours and no signs of severe disease. The same capillary blood was used for the RDTs and the blood slide, the latter used as the gold standard reference. All positive participants were treated with supervised artesunate and amodiaquine treatment for three days. Participants with a persistent false-positive CareStart™, but a negative blood slide on Day 2, were followed with repeated CareStart™ and blood slide tests every seven days until CareStart™ became negative or a maximum of 28 days. Results Sensitivity of CareStart™ was 99.4% (CI 96.8-100.0, 168/169) and of Paracheck-Pf®, 98.8% (95% CI 95.8-99.8, 167/169). Specificity of CareStart™ was 96.0% (CI 91.9-98.4, 167/174) and of Paracheck-Pf®, 74.7% (CI 67.6-81.0, 130/174) (p < 0.001). Neither test showed any change in sensitivity with decreasing parasitaemia. Of the 155 eligible follow-up CareStart™ participants, 63.9% (99/155) had a false-positive test on day 2, 21.3% (33/155) on day 7, 5.8% (9/155) on day 14, 1.9% (3/155) on day 21 and 0.6% (1/155) on day 28. The median time for test negativity was seven days. CareStart™ was as easy to use and interpret as Paracheck-Pf® with excellent inter-reader agreement. Conclusions Both RDTs were highly sensitive, met WHO standards for the detection of falciparum malaria monoinfections where parasitaemia was >100 parasites/μl and were easy to use. CareStart™ persistent false positivity decreased quickly after successful anti-malarial treatment, making it a good choice for a RDT for a hyperendemic falciparum malaria area.
Collapse
Affiliation(s)
- Sibylle Gerstl
- Médecins Sans Frontières (MSF UK), 67-74 Saffron Hill, London EC 1N 8QX, UK.
| | | | | | | | | | | |
Collapse
|
19
|
Evaluation of rapid diagnostic tests for malaria case management in Gabon. Diagn Microbiol Infect Dis 2009; 66:162-8. [PMID: 19846265 DOI: 10.1016/j.diagmicrobio.2009.09.011] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2009] [Revised: 08/31/2009] [Accepted: 09/05/2009] [Indexed: 11/21/2022]
Abstract
A laboratory-confirmed diagnosis is the basis of malaria case management. Rapid diagnostic tests (RDTs) create new opportunities for improved care in endemic areas. Diagnostic performance of OptiMAL-IT and Acon was assessed in comparison with microscopy at 2 sites in Gabon. Between February 2008 and January 2009, 2125 febrile children under 11 years old were diagnosed using microscopy and RDTs. Plasmodial infection was detected more frequently using Acon (27%) and OptiMAL-IT (27%) compared to microscopy (20%) (P < 0.01). Among the samples diagnosed positive by OptiMAL-IT, 78% were infected by Plasmodium falciparum, whereas 99% of positive blood smears were P. falciparum infections, 0.5% Plasmodium malariae, and 0.5% Plasmodium ovale. Both RDTs had similar sensitivity (Se) (94.0%; 95% confidence interval [CI], 92-96), which varied depending on the site. When parasite density was >100 p/microL, the Se of the 2 tests was >98% (95% CI, 96-100). Likewise, the negative predictive values were high and comparable (>98%). Overtreatment with antimalarial drugs was 12%. These tests should be considered as a good alternative to microscopy, allowing not only an efficient and rapid diagnosis of malaria in primary health facilities but also to aid in promoting changes for antimalarial prescription behavior.
Collapse
|
20
|
Ashley EA, Touabi M, Ahrer M, Hutagalung R, Htun K, Luchavez J, Dureza C, Proux S, Leimanis M, Lwin MM, Koscalova A, Comte E, Hamade P, Page AL, Nosten F, Guerin PJ. Evaluation of three parasite lactate dehydrogenase-based rapid diagnostic tests for the diagnosis of falciparum and vivax malaria. Malar J 2009; 8:241. [PMID: 19860920 PMCID: PMC2774865 DOI: 10.1186/1475-2875-8-241] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2009] [Accepted: 10/27/2009] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND In areas where non-falciparum malaria is common rapid diagnostic tests (RDTs) capable of distinguishing malaria species reliably are needed. Such tests are often based on the detection of parasite lactate dehydrogenase (pLDH). METHODS In Dawei, southern Myanmar, three pLDH based RDTs (CareStart Malaria pLDH (Pan), CareStart Malaria pLDH (Pan, Pf) and OptiMAL-IT)were evaluated in patients presenting with clinically suspected malaria. Each RDT was read independently by two readers. A subset of patients with microscopically confirmed malaria had their RDTs repeated on days 2, 7 and then weekly until negative. At the end of the study, samples of study batches were sent for heat stability testing. RESULTS Between August and November 2007, 1004 patients aged between 1 and 93 years were enrolled in the study. Slide microscopy (the reference standard) diagnosed 213 Plasmodium vivax (Pv) monoinfections, 98 Plasmodium falciparum (Pf) mono-infections and no malaria in 650 cases. The sensitivities (sens) and specificities (spec), of the RDTs for the detection of malaria were- CareStart Malaria pLDH (Pan) test: sens 89.1% [CI95 84.2-92.6], spec 97.6% [CI95 96.5-98.4]. OptiMal-IT: Pf+/- other species detection: sens 95.2% [CI95 87.5-98.2], spec 94.7% [CI95 93.3-95.8]; non-Pf detection alone: sens 89.6% [CI95 83.6-93.6], spec 96.5% [CI95 94.8-97.7]. CareStart Malaria pLDH (Pan, Pf): Pf+/- other species: sens 93.5% [CI95 85.4-97.3], spec 97.4% [95.9-98.3]; non-Pf: sens 78.5% [CI95 71.1-84.4], spec 97.8% [CI95 96.3-98.7]. Inter-observer agreement was excellent for all tests (kappa > 0.9). The median time for the RDTs to become negative was two days for the CareStart Malaria tests and seven days for OptiMAL-IT. Tests were heat stable up to 90 days except for OptiMAL-IT (Pf specific pLDH stable to day 20 at 35 degrees C). CONCLUSION None of the pLDH-based RDTs evaluated was able to detect non-falciparum malaria with high sensitivity, particularly at low parasitaemias. OptiMAL-IT performed best overall and would perform best in an area of high malaria prevalence among screened fever cases. However, heat stability was unacceptable and the number of steps to perform this test is a significant drawback in the field. A reliable, heat-stable, highly sensitive RDT, capable of diagnosing all Plasmodium species has yet to be identified.
Collapse
|
21
|
Valéa I, Tinto H, Nikiema M, Yamuah L, Rouamba N, Drabo M, Guiguemde RT, D’Alessandro U. Performance of OptiMAL-IT®compared to microscopy, for malaria detection in Burkina Faso. Trop Med Int Health 2009; 14:338-40. [DOI: 10.1111/j.1365-3156.2009.02228.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
22
|
de Carsalade GY, Lam Kam R, Lepere JF, de Brettes A, Peyramond D. [Can the thick drop/smear examination for malaria be replaced by a rapid diagnostic test in first intention? The Mayotte experience]. Med Mal Infect 2008; 39:36-40. [PMID: 18951743 DOI: 10.1016/j.medmal.2008.09.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2008] [Revised: 07/04/2008] [Accepted: 09/10/2008] [Indexed: 11/29/2022]
Abstract
SETTINGS Malaria is a public health problem in the French island of Mayotte (160,000 inhabitants) in the Indian Ocean. In the late 1990, resistance to chloroquine greatly increased, and so did the number of malaria cases, so that a new health policy had to be adopted. Since 2001, the initial smear/thick drop examination, the results of which took too long to obtain, has systematically been replaced by a rapid diagnosis test (Optimal IT Diamed) in all hospitals and public health centers. METHOD Epidemiological data of malaria on the island was collected and a prospective study was made from March 2005 to February 2006, on two sites (the emergency department of the main hospital and a rural health centre) on all patients presenting with malaria (104 and 139 cases respectively). RESULTS The first Optimal IT test diagnosed the condition accurately in 88 and 96% of the cases, respectively. Every time symptoms would persist after negative test results and an Optimal IT test was repeated within three days, the parasitemia level was low (0.08 to 0.66%). Very low parasitemia level was very likely to account for a false negative (test result). CONCLUSIONS These results concerning malaria (and its epidemiological data) in Mayotte show that the initial use of an Optimal IT test instead of the thin/thick blood smear results in a faster management of patients with malaria, although the Optimal IT test is slightly less sensitive and requires training/practice.
Collapse
Affiliation(s)
- G-Y de Carsalade
- Service des urgences, centre hospitalier de Mayotte, BP 04, 97600 Mamoudzou, Mayotte
| | | | | | | | | |
Collapse
|
23
|
Bharti PK, Silawat N, Singh PP, Singh MP, Shukla M, Chand G, Dash AP, Singh N. The usefulness of a new rapid diagnostic test, the First Response Malaria Combo (pLDH/HRP2) card test, for malaria diagnosis in the forested belt of central India. Malar J 2008; 7:126. [PMID: 18620560 PMCID: PMC2478667 DOI: 10.1186/1475-2875-7-126] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2008] [Accepted: 07/11/2008] [Indexed: 11/24/2022] Open
Abstract
Background Malaria presents a diagnostic challenge in tribal belt of central India where two Plasmodium species, Plasmodium falciparum and Plasmodium vivax, are prevalent. In these areas, rapid detection of the malaria parasites and early treatment of infection remain the most important goals of disease management. Therefore, the usefulness of a new rapid diagnostic (RDT), the First Response® Combo Malaria Ag (pLDH/HRP2) card test was assessed for differential diagnosis between P. falciparum with other Plasmodium species in remote villages of Jabalpur district. Methods A finger prick blood sample was collected to prepare blood smear and for testing with the RDT after taking informed consent. The figures for sensitivity, specificity, accuracy and predictive values were calculated using microscopy as gold standard. Results Analysis revealed that overall, the RDT was 93% sensitive, 85% specific with a positive predictive value (PPV) of 79%, and a negative predictive value (NPV) of 95%. The accuracy 88% and J-index was 0.74. For P. falciparum, the sensitivity and specificity of the test were 96% and 95% respectively, with a PPV of 85% and a NPV of 99%. The RDT accuracy 95% and J-index was 0.84. For non-falciparum malaria, the sensitivity, specificity and accuracy were 83%, 94% and 92% respectively with a PPV of 69% and a NPV of 97%. Conclusion The RDTs are easy to use, reliable and simple to interpret. RDTs are more suited to health workers in situations where health services are deficient or absent. Therefore, the test can be used as an epidemiological tool for the rapid screening of malaria.
Collapse
Affiliation(s)
- Praveen K Bharti
- National Institute of Malaria Research, Field Station, Jabalpur, Madhya Pradesh, India.
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Ratnawati, Hatta M, Smits HL. Point-of-care testing for malaria outbreak management. Trans R Soc Trop Med Hyg 2008; 102:699-704. [PMID: 18513771 DOI: 10.1016/j.trstmh.2008.04.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2007] [Revised: 04/10/2008] [Accepted: 04/10/2008] [Indexed: 10/22/2022] Open
Abstract
A rapid antigen assay for malaria was performed on blood samples collected during a simultaneous outbreak of falciparum malaria and vivax malaria on a remote island in the Indonesian archipelago. During the outbreak, a total of 89 patients (4.3% of the population) were diagnosed with malaria within a week. Microscopic examination revealed 78 malaria slide-positive cases, of whom 49 (62.8%) were identified as P. falciparum, 7 (9.0%) as P. vivax and 22 (28.2%) as mixed P. falciparum and P. vivax infections. The rapid malaria assay showed excellent correlation with expert-confirmed routine microscopy for P. falciparum and P. vivax monoinfections and mixed infections with a parasite density >50 parasites/microl. Several slide-negative blood samples collected from febrile patients with clinical malaria tested positive in the rapid test. The estimated sensitivity calculated for the rapid test (91.0%) was slightly higher than that of microscopy (87.6%). The result indicates that rapid antigen detection for malaria could be a useful alternative to microscopy to reduce the workload during emergency outbreak situations.
Collapse
Affiliation(s)
- Ratnawati
- Department of Parasitology, Hasanuddin University, Makassar, Indonesia
| | | | | |
Collapse
|
25
|
Fogg C, Twesigye R, Batwala V, Piola P, Nabasumba C, Kiguli J, Mutebi F, Hook C, Guillerm M, Moody A, Guthmann JP. Assessment of three new parasite lactate dehydrogenase (pan-pLDH) tests for diagnosis of uncomplicated malaria. Trans R Soc Trop Med Hyg 2007; 102:25-31. [PMID: 18031779 DOI: 10.1016/j.trstmh.2007.09.014] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2006] [Revised: 09/24/2007] [Accepted: 09/25/2007] [Indexed: 11/19/2022] Open
Abstract
A study to assess the diagnostic capabilities of three parasite lactate dehydrogenase (pan-pLDH) tests, Vistapan), Carestart and Parabank), was conducted in Uganda. An HRP2 test, Paracheck-Pf), and a Giemsa-stained blood film were performed with the pLDH tests for outpatients with suspected malaria. In total, 460 subjects were recruited: 248 with positive blood films and 212 with negative blood films. Plasmodium falciparum was present in 95% of infections. Sensitivity above 90% was shown by two pLDH tests, Carestart (95.6%) and Vistapan (91.9%), and specificity above 90% by Parabank (94.3%) and Carestart (91.5%). Sensitivity decreased with low parasitaemia (chi(2) trend, P<0.001); however, all tests achieved sensitivity >90% with parasitaemia > or =100/microl. All tests had good inter-reader reliability (kappa>0.95). Two weeks after diagnosis, 4-10% of pLDH tests were still positive compared with 69.7% of the HRP2 tests. All tests had similar ease of use. In conclusion, two pLDH tests performed well in diagnosing P. falciparum malaria, and all pLDH tests became negative after treatment more quickly than the HRP2. Therefore the rapid test of choice for use with artemisinin-combination therapies in this area would be one of these new pLDH tests.
Collapse
Affiliation(s)
- Carole Fogg
- Epicentre, 8 rue Saint Sabin, 75011, Paris, France.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Gatti S, Gramegna M, Bisoffi Z, Raglio A, Gulletta M, Klersy C, Bruno A, Maserati R, Madama S, Scaglia M. A comparison of three diagnostic techniques for malaria: a rapid diagnostic test (NOW Malaria), PCR and microscopy. ANNALS OF TROPICAL MEDICINE AND PARASITOLOGY 2007; 101:195-204. [PMID: 17362594 DOI: 10.1179/136485907x156997] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
Malaria is a common, life-threatening infection in endemic tropical areas and one that presents a diagnostic challenge to laboratories in most non-endemic countries. A rapid and accurate diagnosis is a prerequisite for effective treatment, especially for the potentially fatal cases of Plasmodium falciparum infection. In the present, multi-centre study, the performances of a rapid diagnostic test (NOW) Malaria) and several, commercial, PCR-based assays (AMS61, AMS42, AMS43, AMS4 and AMS45) were compared against the results of microscopical examination of bloodsmears (the current 'gold standard'). The subjects were either non-European immigrants (N=135) or international travellers (N=171). There was good concordance between the results of all the detection methods, with kappa values of >0.8. Although the NOW Malaria rapid test was both sensitive (100%) and specific (100%) in detecting P. falciparum infections, it was less specific (93.1%) and sensitive (90.7%) in identifying the other Plasmodium species. The results from the AMS61 assay, designed to detect any malarial infection, generally parallelled those of the microscopy (kappa = 0.89), giving a specificity of 98.2% and a sensitivity of 91.0%. Although the use of species-specific molecular primers to identify pure infections with P. falciparum and P. vivax gave results that were in good agreement with those of the microscopy, the subjects who had apparently pure infections with P. ovale or P. malariae were always found PCR-negative. Compared with the standard microscopy, both the NOW Malaria test and the PCR-based assays were therefore poor at identifying mixed infections. The NOW Malaria test and the PCR-based assays clearly need to be improved, particularly for the correct identification of infections with Plasmodium spp. other than P. falciparum, including mixed infections. For now, expert microscopy must remain the mainstay of the laboratory diagnosis of malaria.
Collapse
Affiliation(s)
- S Gatti
- Laboratory of Parasitology, Virology Service, Fondazione IRCCS Policlinico San Matteo, Viale Taramelli 5, 27100 Pavia, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Bell D, Wongsrichanalai C, Barnwell JW. Ensuring quality and access for malaria diagnosis: how can it be achieved? Nat Rev Microbiol 2006; 4:S7-20. [PMID: 17003770 DOI: 10.1038/nrmicro1525] [Citation(s) in RCA: 118] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The replacement of conventional antimalarial drugs with high-cost, artemisinin-based alternatives has created a gap in the successful management of malaria. This gap reflects an increased need for accurate disease diagnosis that cannot be met by traditional microscopy techniques. The recent introduction of rapid diagnostic tests (RDTs) has the potential to meet this need, but successful RDT implementation has been curtailed by poor product performance, inadequate methods to determine the quality of products and a lack of emphasis and capacity to deal with these issues. Economics and a desire for improved case management will result in the rapid growth of RDT use in the coming years. However, for their potential to be realized, it is crucial that high-quality RDT products that perform reliably and accurately under field conditions are made available. In achieving this goal, the shift from symptom-based diagnosis to parasite-based management of malaria can bring significant improvements to tropical fever management, rather than represent a further burden on poor, malaria-endemic populations and their overstretched health services.
Collapse
Affiliation(s)
- David Bell
- Malaria, and other Vector-borne and Parasitic Diseases, World Health Organization Regional Office for the Western Pacific, P.O. Box 2932, Manila, Philippines.
| | | | | |
Collapse
|
28
|
Bell D, Wongsrichanalai C, Barnwell JW. Ensuring quality and access for malaria diagnosis: how can it be achieved? Nat Rev Microbiol 2006; 4:682-95. [PMID: 16912713 DOI: 10.1038/nrmicro1474] [Citation(s) in RCA: 144] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The replacement of conventional antimalarial drugs with high-cost, artemisinin-based alternatives has created a gap in the successful management of malaria. This gap reflects an increased need for accurate disease diagnosis that cannot be met by traditional microscopy techniques. The recent introduction of rapid diagnostic tests (RDTs) has the potential to meet this need, but successful RDT implementation has been curtailed by poor product performance, inadequate methods to determine the quality of products and a lack of emphasis and capacity to deal with these issues. Economics and a desire for improved case management will result in the rapid growth of RDT use in the coming years. However, for their potential to be realized, it is crucial that high-quality RDT products that perform reliably and accurately under field conditions are made available. In achieving this goal, the shift from symptom-based diagnosis to parasite-based management of malaria can bring significant improvements to tropical fever management, rather than represent a further burden on poor, malaria-endemic populations and their overstretched health services.
Collapse
Affiliation(s)
- David Bell
- Malaria, other Vector-borne and Parasitic Diseases, World Health Organization-Regional Office for the Western Pacific, P.O. Box 2932, Manila, Philippines.
| | | | | |
Collapse
|
29
|
Carrara VI, Sirilak S, Thonglairuam J, Rojanawatsirivet C, Proux S, Gilbos V, Brockman A, Ashley EA, McGready R, Krudsood S, Leemingsawat S, Looareesuwan S, Singhasivanon P, White N, Nosten F. Deployment of early diagnosis and mefloquine-artesunate treatment of falciparum malaria in Thailand: the Tak Malaria Initiative. PLoS Med 2006; 3:e183. [PMID: 16719547 PMCID: PMC1470664 DOI: 10.1371/journal.pmed.0030183] [Citation(s) in RCA: 104] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2005] [Accepted: 02/10/2006] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Early diagnosis and treatment with artesunate-mefloquine combination therapy (MAS) have reduced the transmission of falciparum malaria dramatically and halted the progression of mefloquine resistance in camps for displaced persons along the Thai-Burmese border, an area of low and seasonal transmission of multidrug-resistant Plasmodium falciparum. We extended the same combination drug strategy to all other communities (estimated population 450,000) living in five border districts of Tak province in northwestern Thailand. METHODS AND FINDINGS Existing health structures were reinforced. Village volunteers were trained to use rapid diagnostic tests and to treat positive cases with MAS. Cases of malaria, hospitalizations, and malaria-related deaths were recorded in the 6 y before, during, and after the Tak Malaria Initiative (TMI) intervention. Cross-sectional surveys were conducted before and during the TMI period. P. falciparum malaria cases fell by 34% (95% confidence interval [CI], 33.5-34.4) and hospitalisations for falciparum malaria fell by 39% (95% CI, 37.0-39.9) during the TMI period, while hospitalisations for P. vivax malaria remained constant. There were 32 deaths attributed to malaria during, and 22 after the TMI, a 51.5% (95% CI, 39.0-63.9) reduction compared to the average of the previous 3 y. Cross-sectional surveys indicated that P. vivax had become the predominant species in Thai villages, but not in populations living on the Myanmar side of the border. In the displaced persons population, where the original deployment took place 7 y before the TMI, the transmission of P. falciparum continued to be suppressed, the incidence of falciparum malaria remained low, and the in vivo efficacy of the 3-d MAS remained high. CONCLUSIONS In the remote malarious north western border area of Thailand, the early detection of malaria by trained village volunteers, using rapid diagnostic tests and treatment with mefloquine-artesunate was feasible and reduced the morbidity and mortality of multidrug-resistant P. falciparum.
Collapse
Affiliation(s)
- Verena Ilona Carrara
- 1Shoklo Malaria Research Unit, Tak, Thailand
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
- 3Departments of Medical Entomology, Tropical Hygiene and Clinical Tropical Medicine, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | | | | | | | | | | | - Al Brockman
- 1Shoklo Malaria Research Unit, Tak, Thailand
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Elizabeth A Ashley
- 1Shoklo Malaria Research Unit, Tak, Thailand
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
- 6Centre for Vaccinology and Tropical Medicine, Churchill Hospital, Oxford, United Kingdom
| | - Rose McGready
- 1Shoklo Malaria Research Unit, Tak, Thailand
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
- 6Centre for Vaccinology and Tropical Medicine, Churchill Hospital, Oxford, United Kingdom
| | - Srivicha Krudsood
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | | | - Sornchai Looareesuwan
- 3Departments of Medical Entomology, Tropical Hygiene and Clinical Tropical Medicine, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Pratap Singhasivanon
- 3Departments of Medical Entomology, Tropical Hygiene and Clinical Tropical Medicine, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
| | - Nicholas White
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
- 6Centre for Vaccinology and Tropical Medicine, Churchill Hospital, Oxford, United Kingdom
| | - François Nosten
- 1Shoklo Malaria Research Unit, Tak, Thailand
- 2Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand
- 6Centre for Vaccinology and Tropical Medicine, Churchill Hospital, Oxford, United Kingdom
- * To whom correspondence should be addressed. E-mail:
| |
Collapse
|