1
|
Holler C, Taylor RW, Schambony A, Möckl L, Sandoghdar V. A paintbrush for delivery of nanoparticles and molecules to live cells with precise spatiotemporal control. Nat Methods 2024; 21:512-520. [PMID: 38347139 PMCID: PMC10927540 DOI: 10.1038/s41592-024-02177-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 01/08/2024] [Indexed: 03/13/2024]
Abstract
Delivery of very small amounts of reagents to the near-field of cells with micrometer spatial precision and millisecond time resolution is currently out of reach. Here we present μkiss as a micropipette-based scheme for brushing a layer of small molecules and nanoparticles onto the live cell membrane from a subfemtoliter confined volume of a perfusion flow. We characterize our system through both experiments and modeling, and find excellent agreement. We demonstrate several applications that benefit from a controlled brush delivery, such as a direct means to quantify local and long-range membrane mobility and organization as well as dynamical probing of intercellular force signaling.
Collapse
Affiliation(s)
- Cornelia Holler
- Max Planck Institute for the Science of Light, Erlangen, Germany
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
- Department of Biology, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Richard William Taylor
- Max Planck Institute for the Science of Light, Erlangen, Germany
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Alexandra Schambony
- Max Planck Institute for the Science of Light, Erlangen, Germany
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
- Department of Biology, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Leonhard Möckl
- Max Planck Institute for the Science of Light, Erlangen, Germany
| | - Vahid Sandoghdar
- Max Planck Institute for the Science of Light, Erlangen, Germany.
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
- Department of Physics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.
| |
Collapse
|
2
|
Zhu Z, Chen T, Huang F, Wang S, Zhu P, Xu RX, Si T. Free-Boundary Microfluidic Platform for Advanced Materials Manufacturing and Applications. Adv Mater 2024; 36:e2304840. [PMID: 37722080 DOI: 10.1002/adma.202304840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 09/14/2023] [Indexed: 09/20/2023]
Abstract
Microfluidics, with its remarkable capacity to manipulate fluids and droplets at the microscale, has emerged as a powerful platform in numerous fields. In contrast to conventional closed microchannel microfluidic systems, free-boundary microfluidic manufacturing (FBMM) processes continuous precursor fluids into jets or droplets in a relatively spacious environment. FBMM is highly regarded for its superior flexibility, stability, economy, usability, and versatility in the manufacturing of advanced materials and architectures. In this review, a comprehensive overview of recent advancements in FBMM is provided, encompassing technical principles, advanced material manufacturing, and their applications. FBMM is categorized based on the foundational mechanisms, primarily comprising hydrodynamics, interface effects, acoustics, and electrohydrodynamic. The processes and mechanisms of fluid manipulation are thoroughly discussed. Additionally, the manufacturing of advanced materials in various dimensions ranging from zero-dimensional to three-dimensional, as well as their diverse applications in material science, biomedical engineering, and engineering are presented. Finally, current progress is summarized and future challenges are prospected. Overall, this review highlights the significant potential of FBMM as a powerful tool for advanced materials manufacturing and its wide-ranging applications.
Collapse
Affiliation(s)
- Zhiqiang Zhu
- Department of Precision Machinery and Precision Instrumentation, Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China, Hefei, Anhui, 230026, China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, 999077, China
| | - Tianao Chen
- School of Biomedical Engineering, Division of Life Sciences and Medicine, Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
| | - Fangsheng Huang
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui, 230026, China
| | - Shiyu Wang
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, 999077, China
| | - Pingan Zhu
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, 999077, China
| | - Ronald X Xu
- Department of Precision Machinery and Precision Instrumentation, Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, University of Science and Technology of China, Hefei, Anhui, 230026, China
- School of Biomedical Engineering, Division of Life Sciences and Medicine, Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
| | - Ting Si
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|
3
|
Monserrat Lopez D, Rottmann P, Fussenegger M, Lörtscher E. Silicon-Based 3D Microfluidics for Parallelization of Droplet Generation. Micromachines (Basel) 2023; 14:1289. [PMID: 37512600 PMCID: PMC10386391 DOI: 10.3390/mi14071289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 06/20/2023] [Accepted: 06/21/2023] [Indexed: 07/30/2023]
Abstract
Both the diversity and complexity of microfluidic systems have experienced a tremendous progress over the last decades, enabled by new materials, novel device concepts and innovative fabrication routes. In particular the subfield of high-throughput screening, used for biochemical, genetic and pharmacological samples, has extensively emerged from developments in droplet microfluidics. More recently, new 3D device architectures enabled either by stacking layers of PDMS or by direct 3D-printing have gained enormous attention for applications in chemical synthesis or biomedical assays. While the first microfluidic devices were based on silicon and glass structures, those materials have not yet been significantly expanded towards 3D despite their high chemical compatibility, mechanical strength or mass-production potential. In our work, we present a generic fabrication route based on the implementation of vertical vias and a redistribution layer to create glass-silicon-glass 3D microfluidic structures. It is used to build different droplet-generating devices with several flow-focusing junctions in parallel, all fed from a single source. We study the effect of having several of these junctions in parallel by varying the flow conditions of both the continuous and the dispersed phases. We demonstrate that the generic concept enables an upscaling in the production rate by increasing the number of droplet generators per device without sacrificing the monodispersity of the droplets.
Collapse
Affiliation(s)
- Diego Monserrat Lopez
- IBM Research Europe-Zurich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
- Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, CH-4058 Basel, Switzerland
| | - Philipp Rottmann
- Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, CH-4058 Basel, Switzerland
| | - Martin Fussenegger
- Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, CH-4058 Basel, Switzerland
- Faculty of Science, University of Basel, Mattenstrasse 26, CH-4058 Basel, Switzerland
| | - Emanuel Lörtscher
- IBM Research Europe-Zurich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
| |
Collapse
|
4
|
Du X, Kaneko S, Maruyama H, Sugiura H, Tsujii M, Uozumi N, Arai F. Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response. Micromachines (Basel) 2023; 14:1210. [PMID: 37374795 DOI: 10.3390/mi14061210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 06/03/2023] [Accepted: 06/05/2023] [Indexed: 06/29/2023]
Abstract
The integration of liquid exchange and microfluidic chips plays a critical role in the biomedical and biophysical fields as it enables the control of the extracellular environment and allows for the simultaneous stimulation and detection of single cells. In this study, we present a novel approach for measuring the transient response of single cells using a system integrated with a microfluidic chip and a probe with a dual pump. The system was composed of a probe with a dual pump system, a microfluidic chip, optical tweezers, an external manipulator, an external piezo actuator, etc. Particularly, we incorporated the probe with the dual pump to allow for high-speed liquid change, and the localized flow control enabled a low disturbance contact force detection of single cells on the chip. Using this system, we measured the transient response of the cell swelling against the osmotic shock with a very fine time resolution. To demonstrate the concept, we first designed the double-barreled pipette, which was assembled with two piezo pumps to achieve a probe with the dual pump system, allowing for simultaneous liquid injection and suction. The microfluidic chip with on-chip probes was fabricated, and the integrated force sensor was calibrated. Second, we characterized the performance of the probe with the dual pump system, and the effect of the analysis position and area of the liquid exchange time was investigated. In addition, we optimized the applied injection voltage to achieve a complete concentration change, and the average liquid exchange time was achieved at approximately 3.33 ms. Finally, we demonstrated that the force sensor was only subjected to minor disturbances during the liquid exchange. This system was utilized to measure the deformation and the reactive force of Synechocystis sp. strain PCC 6803 in osmotic shock, with an average response time of approximately 16.33 ms. This system reveals the transient response of compressed single cells under millisecond osmotic shock which has the potential to characterize the accurate physiological function of ion channels.
Collapse
Affiliation(s)
- Xu Du
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8603, Japan
| | - Shingo Kaneko
- Department of Mechanical Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Hisataka Maruyama
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8603, Japan
| | - Hirotaka Sugiura
- Department of Mechanical Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Masaru Tsujii
- Department of Biomolecular Engineering, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Nobuyuki Uozumi
- Department of Biomolecular Engineering, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Fumihito Arai
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8603, Japan
- Department of Mechanical Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| |
Collapse
|
5
|
Boulais E, Gervais T. The 2D microfluidics cookbook - modeling convection and diffusion in plane flow devices. Lab Chip 2023; 23:1967-1980. [PMID: 36884010 DOI: 10.1039/d2lc01033j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
A growing number of microfluidic systems operate not through networks of microchannels but instead through using 2D flow fields. While the design rules for channel networks are already well-known and exposed in microfluidics textbooks, the knowledge underlying transport in 2D microfluidics remains scattered piecemeal and is not easily accessible to experimentalists and engineers. In this tutorial review, we formulate a unified framework for understanding, analyzing and designing 2D microfluidic technologies. We first show how a large number of seemingly different devices can all be modelled using the same concepts, namely flow and diffusion in a Hele-Shaw cell. We then expose a handful of mathematical tools, accessible to any engineer with undergraduate level mathematics knowledge, namely potential flow, superposition of charges, conformal transforms and basic convection-diffusion. We show how these tools can be combined to obtain a simple "recipe" that models almost any imaginable 2D microfluidic system. We end by pointing to more advanced topics beyond 2D microfluidics, namely interface problems and flow and diffusion in the third dimension. This forms the basis of a complete theory allowing for the design and operation of new microfluidic systems.
Collapse
Affiliation(s)
- Etienne Boulais
- Polytechnique Montreal, 2500 Chemin de Polytechnique, Montréal, QC H3T 1J4, Canada.
| | - Thomas Gervais
- Polytechnique Montreal, 2500 Chemin de Polytechnique, Montréal, QC H3T 1J4, Canada.
- Institut du Cancer de Montréal (ICM) and Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), Canada
| |
Collapse
|
6
|
Puumala LS, Grist SM, Morales JM, Bickford JR, Chrostowski L, Shekhar S, Cheung KC. Biofunctionalization of Multiplexed Silicon Photonic Biosensors. Biosensors (Basel) 2022; 13:bios13010053. [PMID: 36671887 PMCID: PMC9855810 DOI: 10.3390/bios13010053] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/10/2022] [Accepted: 12/23/2022] [Indexed: 05/28/2023]
Abstract
Silicon photonic (SiP) sensors offer a promising platform for robust and low-cost decentralized diagnostics due to their high scalability, low limit of detection, and ability to integrate multiple sensors for multiplexed analyte detection. Their CMOS-compatible fabrication enables chip-scale miniaturization, high scalability, and low-cost mass production. Sensitive, specific detection with silicon photonic sensors is afforded through biofunctionalization of the sensor surface; consequently, this functionalization chemistry is inextricably linked to sensor performance. In this review, we first highlight the biofunctionalization needs for SiP biosensors, including sensitivity, specificity, cost, shelf-stability, and replicability and establish a set of performance criteria. We then benchmark biofunctionalization strategies for SiP biosensors against these criteria, organizing the review around three key aspects: bioreceptor selection, immobilization strategies, and patterning techniques. First, we evaluate bioreceptors, including antibodies, aptamers, nucleic acid probes, molecularly imprinted polymers, peptides, glycans, and lectins. We then compare adsorption, bioaffinity, and covalent chemistries for immobilizing bioreceptors on SiP surfaces. Finally, we compare biopatterning techniques for spatially controlling and multiplexing the biofunctionalization of SiP sensors, including microcontact printing, pin- and pipette-based spotting, microfluidic patterning in channels, inkjet printing, and microfluidic probes.
Collapse
Affiliation(s)
- Lauren S. Puumala
- School of Biomedical Engineering, University of British Columbia, 2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Centre for Blood Research, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
| | - Samantha M. Grist
- School of Biomedical Engineering, University of British Columbia, 2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Centre for Blood Research, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
| | - Jennifer M. Morales
- Army Research Laboratory, US Army Combat Capabilities Development Command, 2800 Powder Mill Rd., Adelphi, MD 20783, USA
| | - Justin R. Bickford
- Army Research Laboratory, US Army Combat Capabilities Development Command, 2800 Powder Mill Rd., Adelphi, MD 20783, USA
| | - Lukas Chrostowski
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
- Department of Electrical and Computer Engineering, University of British Columbia, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
- Stewart Blusson Quantum Matter Institute, University of British Columbia, 2355 East Mall, Vancouver, BC V6T 1Z4, Canada
| | - Sudip Shekhar
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
- Department of Electrical and Computer Engineering, University of British Columbia, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| | - Karen C. Cheung
- School of Biomedical Engineering, University of British Columbia, 2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Centre for Blood Research, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Department of Electrical and Computer Engineering, University of British Columbia, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| |
Collapse
|
7
|
Ota N, Tanaka N, Sato A, Shen Y, Yalikun Y, Tanaka Y. Microenvironmental Analysis and Control for Local Cells under Confluent Conditions via a Capillary-Based Microfluidic Device. Anal Chem 2022; 94:16299-16307. [DOI: 10.1021/acs.analchem.2c02815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Nobutoshi Ota
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka565-0871, Japan
| | - Nobuyuki Tanaka
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka565-0871, Japan
| | - Asako Sato
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka565-0871, Japan
| | - Yigang Shen
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka565-0871, Japan
| | - Yaxiaer Yalikun
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka565-0871, Japan
- Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama-cho, Ikoma, Nara630-0192, Japan
| | - Yo Tanaka
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka565-0871, Japan
| |
Collapse
|
8
|
Mathur P, Fomitcheva Khartchenko A, Stavrakis S, Kaigala GV, deMello AJ. Quantifying Antibody Binding Kinetics on Fixed Cells and Tissues via Fluorescence Lifetime Imaging. Anal Chem 2022; 94:10967-10975. [PMID: 35895913 DOI: 10.1021/acs.analchem.2c01076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We present a method for monitoring spatially localized antigen-antibody binding events on physiologically relevant substrates (cell and tissue sections) using fluorescence lifetime imaging. Specifically, we use the difference between the fluorescence decay times of fluorescently tagged antibodies in free solution and in the bound state to track the bound fraction over time and hence deduce the binding kinetics. We make use of a microfluidic probe format to minimize the mass transport effects and localize the analysis to specific regions of interest on the biological substrates. This enables measurement of binding constants (kon) on surface-bound antigens and on cell blocks using model biomarkers. Finally, we directly measure p53 kinetics with differential biomarker expression in ovarian cancer tissue sections, observing that the degree of expression corresponds to the changes in kon, with values of 3.27-3.50 × 103 M-1 s-1 for high biomarker expression and 2.27-2.79 × 103 M-1 s-1 for low biomarker expression.
Collapse
Affiliation(s)
- Prerit Mathur
- Institute for Chemical and Bioengineering, Department of Chemistry & Applied Biosciences, Eidgenössische Technische Hochschule (ETH Zürich), Vladimir-Prelog-Weg 1-5/10, 8093 Zürich, Switzerland.,IBM Research Europe─Zurich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
| | - Anna Fomitcheva Khartchenko
- Institute for Chemical and Bioengineering, Department of Chemistry & Applied Biosciences, Eidgenössische Technische Hochschule (ETH Zürich), Vladimir-Prelog-Weg 1-5/10, 8093 Zürich, Switzerland.,IBM Research Europe─Zurich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
| | - Stavros Stavrakis
- Institute for Chemical and Bioengineering, Department of Chemistry & Applied Biosciences, Eidgenössische Technische Hochschule (ETH Zürich), Vladimir-Prelog-Weg 1-5/10, 8093 Zürich, Switzerland
| | - Govind V Kaigala
- IBM Research Europe─Zurich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland.,School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada
| | - Andrew J deMello
- Institute for Chemical and Bioengineering, Department of Chemistry & Applied Biosciences, Eidgenössische Technische Hochschule (ETH Zürich), Vladimir-Prelog-Weg 1-5/10, 8093 Zürich, Switzerland
| |
Collapse
|
9
|
Taylor DP, Mathur P, Renaud P, Kaigala GV. Microscale hydrodynamic confinements: shaping liquids across length scales as a toolbox in life sciences. Lab Chip 2022; 22:1415-1437. [PMID: 35348555 DOI: 10.1039/d1lc01101d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hydrodynamic phenomena can be leveraged to confine a range of biological and chemical species without needing physical walls. In this review, we list methods for the generation and manipulation of microfluidic hydrodynamic confinements in free-flowing liquids and near surfaces, and elucidate the associated underlying theory and discuss their utility in the emerging area of open space microfluidics applied to life-sciences. Microscale hydrodynamic confinements are already starting to transform approaches in fundamental and applied life-sciences research from precise separation and sorting of individual cells, allowing localized bio-printing to multiplexing for clinical diagnosis. Through the choice of specific flow regimes and geometrical boundary conditions, hydrodynamic confinements can confine species across different length scales from small molecules to large cells, and thus be applied to a wide range of functionalities. We here provide practical examples and implementations for the formation of these confinements in different boundary conditions - within closed channels, in between parallel plates and in an open liquid volume. Further, to enable non-microfluidics researchers to apply hydrodynamic flow confinements in their work, we provide simplified instructions pertaining to their design and modelling, as well as to the formation of hydrodynamic flow confinements in the form of step-by-step tutorials and analytical toolbox software. This review is written with the idea to lower the barrier towards the use of hydrodynamic flow confinements in life sciences research.
Collapse
Affiliation(s)
- David P Taylor
- IBM Research - Europe, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.
- Microsystems Laboratory 4, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Prerit Mathur
- IBM Research - Europe, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.
- Dept. of Chemistry and Applied Biosciences, Eidgenössische Technische Hochschule (ETH), Vladimir-Prelog-Weg 1-5/10, 8093 Zurich, Switzerland
| | - Philippe Renaud
- Microsystems Laboratory 4, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Govind V Kaigala
- IBM Research - Europe, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.
| |
Collapse
|
10
|
Pereiro I, Kartchenko AF, Lovchik RD, Kaigala GV. Simple add-on devices to enhance the efficacy of conventional surface immunoassays implemented on standard labware. Analyst 2022; 147:2040-2047. [DOI: 10.1039/d2an00214k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We propose microfluidic add-ons easily placed on standard assay labware such as microwells and slides to enhance the kinetics of immunoassays. The devices are compatible with mass production, well-established assay protocols and automated platforms.
Collapse
Affiliation(s)
- Iago Pereiro
- IBM Research Europe – Zurich, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland
| | | | - Robert D. Lovchik
- IBM Research Europe – Zurich, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland
| | - Govind V. Kaigala
- IBM Research Europe – Zurich, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland
| |
Collapse
|
11
|
Fomitcheva-Khartchenko A, Rapsomaniki MA, Sobottka B, Schraml P, Kaigala GV. Spatial protein heterogeneity analysis in frozen tissues to evaluate tumor heterogeneity. PLoS One 2021; 16:e0259332. [PMID: 34797831 PMCID: PMC8604290 DOI: 10.1371/journal.pone.0259332] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 10/19/2021] [Indexed: 11/19/2022] Open
Abstract
A new workflow for protein-based tumor heterogeneity probing in tissues is here presented. Tumor heterogeneity is believed to be key for therapy failure and differences in prognosis in cancer patients. Comprehending tumor heterogeneity, especially at the protein level, is critical for tracking tumor evolution, and showing the presence of different phenotypical variants and their location with respect to tissue architecture. Although a variety of techniques is available for quantifying protein expression, the heterogeneity observed in the tissue is rarely addressed. The proposed method is validated in breast cancer fresh-frozen tissues derived from five patients. Protein expression is quantified on the tissue regions of interest (ROI) with a resolution of up to 100 μm in diameter. High heterogeneity values across the analyzed patients in proteins such as cytokeratin 7, β-actin and epidermal growth factor receptor (EGFR) using a Shannon entropy analysis are observed. Additionally, ROIs are clustered according to their expression levels, showing their location in the tissue section, and highlighting that similar phenotypical variants are not always located in neighboring regions. Interestingly, a patient with a phenotype related to increased aggressiveness of the tumor presents a unique protein expression pattern. In summary, a workflow for the localized extraction and protein analysis of regions of interest from frozen tissues, enabling the evaluation of tumor heterogeneity at the protein level is presented.
Collapse
Affiliation(s)
| | | | - Bettina Sobottka
- Department of Pathology and Molecular Pathology, University Hospital Zurich and University Zurich, Zurich, Switzerland
| | - Peter Schraml
- Department of Pathology and Molecular Pathology, University Hospital Zurich and University Zurich, Zurich, Switzerland
| | | |
Collapse
|
12
|
Abstract
Patterning biomolecules on surfaces provides numerous opportunities for miniaturizing biological assays; biosensing; studying proteins, cells, and tissue sections; and engineering surfaces that include biological components. In this Feature Article, we summarize the themes presented in our recent Langmuir Lecture on patterning biomolecules on surfaces, miniaturizing surface assays, and interacting with biointerfaces using three key technologies: microcontact printing, microfluidic networks, and microfluidic probes.
Collapse
Affiliation(s)
- Emmanuel Delamarche
- IBM Research Europe-Zurich, Säumerstrasse 4, Rüschlikon CH-8803, Switzerland
| | - Iago Pereiro
- IBM Research Europe-Zurich, Säumerstrasse 4, Rüschlikon CH-8803, Switzerland
| | - Aditya Kashyap
- IBM Research Europe-Zurich, Säumerstrasse 4, Rüschlikon CH-8803, Switzerland
| | - Govind V Kaigala
- IBM Research Europe-Zurich, Säumerstrasse 4, Rüschlikon CH-8803, Switzerland
| |
Collapse
|
13
|
Voith von Voithenberg L, Kashyap A, Opitz L, Aquino C, Sykes T, Nieser M, Petrini LFT, Enrriquez Casimiro N, van Kooten XF, Biskup S, Schlapbach R, Schraml P, Kaigala GV. Mapping Spatial Genetic Landscapes in Tissue Sections through Microscale Integration of Sampling Methodology into Genomic Workflows. Small 2021; 17:e2007901. [PMID: 33852760 DOI: 10.1002/smll.202007901] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 02/12/2021] [Indexed: 06/12/2023]
Abstract
In cancer research, genomic profiles are often extracted from homogenized macrodissections of tissues, with the histological context lost and a large fraction of material underutilized. Pertinently, the spatial genomic landscape provides critical complementary information in deciphering disease heterogeneity and progression. Microscale sampling methods such as microdissection to obtain such information are often destructive to a sizeable fraction of the biopsy sample, thus showing limited multiplexability and adaptability to different assays. A modular microfluidic technology is here implemented to recover cells at the microscale from tumor tissue sections, with minimal disruption of unsampled areas and tailored to interface with genome profiling workflows, which is directed here toward evaluating intratumoral genomic heterogeneity. The integrated workflow-GeneScape-is used to evaluate heterogeneity in a metastatic mammary carcinoma, showing distinct single nucleotide variants and copy number variations in different tumor tissue regions, suggesting the polyclonal origin of the metastasis as well as development driven by multiple location-specific drivers.
Collapse
Affiliation(s)
| | - Aditya Kashyap
- IBM Research Europe, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland
| | - Lennart Opitz
- Functional Genomics Center Zurich, Winterthurerstr. 190, Zurich, CH-8057, Switzerland
| | - Catharine Aquino
- Functional Genomics Center Zurich, Winterthurerstr. 190, Zurich, CH-8057, Switzerland
| | - Timothy Sykes
- Functional Genomics Center Zurich, Winterthurerstr. 190, Zurich, CH-8057, Switzerland
| | - Maike Nieser
- Center for Genomics and Transcriptomics, Paul-Ehrlich-Str. 23, 72076, Tübingen, Germany
| | | | | | | | - Saskia Biskup
- Center for Genomics and Transcriptomics, Paul-Ehrlich-Str. 23, 72076, Tübingen, Germany
| | - Ralph Schlapbach
- Functional Genomics Center Zurich, Winterthurerstr. 190, Zurich, CH-8057, Switzerland
| | - Peter Schraml
- Department of Pathology and Molecular Pathology, University Hospital Zurich, Schmelzbergstr. 12, Zurich, CH-8091, Switzerland
| | - Govind V Kaigala
- IBM Research Europe, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland
| |
Collapse
|
14
|
Zhang Q, Feng S, Li W, Xie T, Zhang W, Lin J. In Situ Stable Generation of Reactive Intermediates by Open Microfluidic Probe for Subcellular Free Radical Attack and Membrane Labeling. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202016171] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Qiang Zhang
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Shuo Feng
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Weiwei Li
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Tianze Xie
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Wanling Zhang
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Jin‐Ming Lin
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| |
Collapse
|
15
|
Zhang Q, Feng S, Li W, Xie T, Zhang W, Lin J. In Situ Stable Generation of Reactive Intermediates by Open Microfluidic Probe for Subcellular Free Radical Attack and Membrane Labeling. Angew Chem Int Ed Engl 2021; 60:8483-8487. [DOI: 10.1002/anie.202016171] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 01/07/2021] [Indexed: 01/19/2023]
Affiliation(s)
- Qiang Zhang
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Shuo Feng
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Weiwei Li
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Tianze Xie
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Wanling Zhang
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| | - Jin‐Ming Lin
- Department of Chemistry Beijing Key Laboratory of Microanalytical Methods and Instrumentation MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology Tsinghua University Beijing 100084 China
| |
Collapse
|
16
|
Shinha K, Nihei W, Kimura H. A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells. Micromachines (Basel) 2020; 11:mi11070691. [PMID: 32708814 PMCID: PMC7408473 DOI: 10.3390/mi11070691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/05/2020] [Accepted: 07/14/2020] [Indexed: 11/16/2022]
Abstract
Numerous in vitro studies have been conducted in conventional static cell culture systems. However, most of the results represent an average response from a population of cells regardless of their local microenvironment. A microfluidic probe is a non-contact technology that has been widely used to perform local chemical stimulation within a restricted space, providing elaborated modulation and analysis of cellular responses within the microenvironment. Although microfluidic probes developed earlier have various potential applications, the two-dimensional structure can compromise their functionality and flexibility for practical use. In this study, we developed a three-dimensional microfluidic probe integrated device equipped with vertically oriented microchannels to overcome crucial challenges and tested the potential utility of the device in biological research. We demonstrated that the device tightly regulated spatial diffusion of a fluorescent molecule, and the flow profile predicted by simulation replicated the experimental results. Additionally, the device modulated the physiological Ca2+ response of cells within the restricted area by altering the local and temporal concentrations of biomolecules such as ATP. The novel device developed in this study may provide various applications for biological studies and contribute to further understanding of molecular mechanisms underlying cellular physiology.
Collapse
Affiliation(s)
- Kenta Shinha
- Department of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan; (K.S.); (W.N.)
| | - Wataru Nihei
- Department of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan; (K.S.); (W.N.)
- Micro/Nano Technology Center (MNTC), Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
| | - Hiroshi Kimura
- Department of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan; (K.S.); (W.N.)
- Micro/Nano Technology Center (MNTC), Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
- Correspondence: ; Tel.: +81-463-58-1211
| |
Collapse
|
17
|
Chen P, Li S, Guo Y, Zeng X, Liu BF. A review on microfluidics manipulation of the extracellular chemical microenvironment and its emerging application to cell analysis. Anal Chim Acta 2020; 1125:94-113. [PMID: 32674786 DOI: 10.1016/j.aca.2020.05.065] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 05/22/2020] [Accepted: 05/26/2020] [Indexed: 12/22/2022]
Abstract
Spatiotemporal manipulation of extracellular chemical environments with simultaneous monitoring of cellular responses plays an essential role in exploring fundamental biological processes and expands our understanding of underlying mechanisms. Despite the rapid progress and promising successes in manipulation strategies, many challenges remain due to the small size of cells and the rapid diffusion of chemical molecules. Fortunately, emerging microfluidic technology has become a powerful approach for precisely controlling the extracellular chemical microenvironment, which benefits from its integration capacity, automation, and high-throughput capability, as well as its high resolution down to submicron. Here, we summarize recent advances in microfluidics manipulation of the extracellular chemical microenvironment, including the following aspects: i) Spatial manipulation of chemical microenvironments realized by convection flow-, diffusion-, and droplet-based microfluidics, and surface chemical modification; ii) Temporal manipulation of chemical microenvironments enabled by flow switching/shifting, moving/flowing cells across laminar flows, integrated microvalves/pumps, and droplet manipulation; iii) Spatiotemporal manipulation of chemical microenvironments implemented by a coupling strategy and open-space microfluidics; and iv) High-throughput manipulation of chemical microenvironments. Finally, we briefly present typical applications of the above-mentioned technical advances in cell-based analyses including cell migration, cell signaling, cell differentiation, multicellular analysis, and drug screening. We further discuss the future improvement of microfluidics manipulation of extracellular chemical microenvironments to fulfill the needs of biological and biomedical research and applications.
Collapse
Affiliation(s)
- Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiran Guo
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xuemei Zeng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China.
| |
Collapse
|
18
|
Abstract
Metal–organic frameworks (MOFs) have been of great interest for their outstanding properties, such as large surface area, low density, tunable pore size and functionality, excellent structural flexibility, and good chemical stability. A significant advancement in the preparation of MOF thin films according to the needs of a variety of applications has been achieved in the past decades. Yet there is still high demand in advancing the understanding of the processes to realize more scalable, controllable, and greener synthesis. This review provides a summary of the current progress on the manufacturing of MOF thin films, including the various thin-film deposition processes, the approaches to modify the MOF structure and pore functionality, and the means to prepare patterned MOF thin films. The suitability of different synthesis techniques under various processing environments is analyzed. Finally, we discuss opportunities for future development in the manufacturing of MOF thin films.
Collapse
|
19
|
Voith von Voithenberg L, Fomitcheva Khartchenko A, Huber D, Schraml P, Kaigala GV. Spatially multiplexed RNA in situ hybridization to reveal tumor heterogeneity. Nucleic Acids Res 2020; 48:e17. [PMID: 31853536 PMCID: PMC7026647 DOI: 10.1093/nar/gkz1151] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 11/20/2019] [Accepted: 12/03/2019] [Indexed: 02/07/2023] Open
Abstract
Multiplexed RNA in situ hybridization for the analysis of gene expression patterns plays an important role in investigating development and disease. Here, we present a method for multiplexed RNA-ISH to detect spatial tumor heterogeneity in tissue sections. We made use of a microfluidic chip to deliver ISH-probes locally to regions of a few hundred micrometers over time periods of tens of minutes. This spatial multiplexing method can be combined with ISH-approaches based on signal amplification, with bright field detection and with the commonly used format of formalin-fixed paraffin-embedded tissue sections. By using this method, we analyzed the expression of HER2 with internal positive and negative controls (ActB, dapB) as well as predictive biomarker panels (ER, PgR, HER2) in a spatially multiplexed manner on single mammary carcinoma sections. We further demonstrated the applicability of the technique for subtype differentiation in breast cancer. Local analysis of HER2 revealed medium to high spatial heterogeneity of gene expression (Cohen effect size r = 0.4) in equivocally tested tumor tissues. Thereby, we exemplify the importance of using such a complementary approach for the analysis of spatial heterogeneity, in particular for equivocally tested tumor samples. As the method is compatible with a range of ISH approaches and tissue samples, it has the potential to find broad applicability in the context of molecular analysis of human diseases.
Collapse
Affiliation(s)
| | | | - Deborah Huber
- IBM Research Zürich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
| | - Peter Schraml
- University Hospital Zurich, Department of Pathology and Molecular Pathology, Schmelzbergstr. 12, CH-8091 Zurich, Switzerland
| | - Govind V Kaigala
- IBM Research Zürich, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
| |
Collapse
|
20
|
Abstract
The theoretical analysis and experimental demonstration of a new concept are presented for a non-contact scanning probe, in which transport of fluid and molecules is controlled by electric fields. The electrokinetic scanning probe (ESP) enables local chemical and biochemical interactions with surfaces in liquid environments. The physical mechanism and design criteria for such a probe are presented, and its compatibility with a wide range of processing solutions and pH values are demonstrated. The applicability of the probe is shown for surface patterning in conjunction with localized heating and 250-fold analyte stacking.
Collapse
Affiliation(s)
- Nadya Ostromohov
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
- IBM Research-Zurich, Saeumerstrasse 4, CH-8803, Rueschlikon, Switzerland
| | - Baruch Rofman
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Moran Bercovici
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Govind Kaigala
- IBM Research-Zurich, Saeumerstrasse 4, CH-8803, Rueschlikon, Switzerland
| |
Collapse
|
21
|
Rodriguez-Mateos P, Azevedo NF, Almeida C, Pamme N. FISH and chips: a review of microfluidic platforms for FISH analysis. Med Microbiol Immunol 2020; 209:373-391. [PMID: 31965296 PMCID: PMC7248050 DOI: 10.1007/s00430-019-00654-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 12/19/2019] [Indexed: 12/12/2022]
Abstract
Fluorescence in situ hybridization (FISH) allows visualization of specific nucleic acid sequences within an intact cell or a tissue section. It is based on molecular recognition between a fluorescently labeled probe that penetrates the cell membrane of a fixed but intact sample and hybridizes to a nucleic acid sequence of interest within the cell, rendering a measurable signal. FISH has been applied to, for example, gene mapping, diagnosis of chromosomal aberrations and identification of pathogens in complex samples as well as detailed studies of cellular structure and function. However, FISH protocols are complex, they comprise of many fixation, incubation and washing steps involving a range of solvents and temperatures and are, thus, generally time consuming and labor intensive. The complexity of the process, the relatively high-priced fluorescent probes and the fairly high-end microscopy needed for readout render the whole process costly and have limited wider uptake of this powerful technique. In recent years, there have been attempts to transfer FISH assay protocols onto microfluidic lab-on-a-chip platforms, which reduces the required amount of sample and reagents, shortens incubation times and, thus, time to complete the protocol, and finally has the potential for automating the process. Here, we review the wide variety of approaches for lab-on-chip-based FISH that have been demonstrated at proof-of-concept stage, ranging from FISH analysis of immobilized cell layers, and cells trapped in arrays, to FISH on tissue slices. Some researchers have aimed to develop simple devices that interface with existing equipment and workflows, whilst others have aimed to integrate the entire FISH protocol into a fully autonomous FISH on-chip system. Whilst the technical possibilities for FISH on-chip are clearly demonstrated, only a small number of approaches have so far been converted into off-the-shelf products for wider use beyond the research laboratory.
Collapse
Affiliation(s)
- Pablo Rodriguez-Mateos
- Department of Chemistry and Biochemistry, University of Hull, Cottingham Road, Hull, HU6 7RX, UK
| | - Nuno Filipe Azevedo
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465, Porto, Portugal.,Biomode SA, Av. Mestre José Veiga, 4715-330, Braga, Portugal
| | - Carina Almeida
- Biomode SA, Av. Mestre José Veiga, 4715-330, Braga, Portugal.,INIAV, I.P.-National Institute for Agricultural and Veterinary Research, Rua dos Lagidos, Lugar da Madalena, Vairão, 4485-655, Vila Do Conde, Portugal.,CEB-Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal
| | - Nicole Pamme
- Department of Chemistry and Biochemistry, University of Hull, Cottingham Road, Hull, HU6 7RX, UK.
| |
Collapse
|
22
|
Lovchik RD, Taylor D, Kaigala G. Rapid micro-immunohistochemistry. Microsyst Nanoeng 2020; 6:94. [PMID: 34567704 PMCID: PMC8433409 DOI: 10.1038/s41378-020-00205-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 08/06/2020] [Accepted: 08/07/2020] [Indexed: 05/04/2023]
Abstract
We present a new and versatile implementation of rapid and localized immunohistochemical staining of tissue sections. Immunohistochemistry (IHC) comprises a sequence of specific biochemical reactions and allows the detection of specific proteins in tissue sections. For the rapid implementation of IHC, we fabricated horizontally oriented microfluidic probes (MFPs) with functionally designed apertures to enable square and circular footprints, which we employ to locally expose a tissue to time-optimized sequences of different biochemicals. We show that the two main incubation steps of IHC protocols can be performed on MDAMB468-1510A cell block sections in less than 30 min, compared to incubation times of an hour or more in standard protocols. IHC analysis on the timescale of tens of minutes could potentially be applied during surgery, enabling clinicians to react in more dynamically and efficiently. Furthermore, this rapid IHC implementation along with conservative tissue usage has strong potential for the implementation of multiplexed assays, allowing the exploration of optimal assay conditions with a small amount of tissue to ensure high-quality staining results for the remainder of the sample.
Collapse
Affiliation(s)
- Robert D. Lovchik
- IBM Research Europe, Saeumerstrasse 4, 8803 Rueschlikon, Switzerland
| | - David Taylor
- IBM Research Europe, Saeumerstrasse 4, 8803 Rueschlikon, Switzerland
- Present Address: Eidgenössische Technische Hochschule Zürich, Department of Mechanical and Process Engineering, Sonneggstrasse 3, 8092 Zurich, Switzerland
| | - Govind Kaigala
- IBM Research Europe, Saeumerstrasse 4, 8803 Rueschlikon, Switzerland
| |
Collapse
|
23
|
Abstract
This review discusses on various bonding techniques for fabricating microdevices with a special emphasis on the modification of surface assisted by the use of chemicals to assemble microfluidic devices at room temperature under atmospheric pressure.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of Industrial and Environmental Engineering
- College of Industrial Environmental Engineering
- Gachon University
- Seongnam-si
- Korea
| | - Nae Yoon Lee
- Department of BioNano Technology
- Gachon University
- Seongnam-si
- Korea
| |
Collapse
|
24
|
|
25
|
Patabadige DEW, Millet LJ, Aufrecht JA, Shankles PG, Standaert RF, Retterer ST, Doktycz MJ. Label-free time- and space-resolved exometabolite sampling of growing plant roots through nanoporous interfaces. Sci Rep 2019; 9:10272. [PMID: 31312009 DOI: 10.1038/s41598-019-46538-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Accepted: 06/21/2019] [Indexed: 11/09/2022] Open
Abstract
Spatial and temporal profiling of metabolites within and between living systems is vital to understanding how chemical signaling shapes the composition and function of these complex systems. Measurement of metabolites is challenging because they are often not amenable to extrinsic tags, are diverse in nature, and are present with a broad range of concentrations. Moreover, direct imaging by chemically informative tools can significantly compromise viability of the system of interest or lack adequate resolution. Here, we present a nano-enabled and label-free imaging technology using a microfluidic sampling network to track production and distribution of chemical information in the microenvironment of a living organism. We describe the integration of a polyester track-etched (PETE) nanofluidic interface to physically confine the biological sample within the model environment, while allowing fluidic access via an underlying microfluidic network. The nanoporous interface enables sampling of the microenvironment above in a time-dependent and spatially-resolved manner. For demonstration, the diffusional flux through the PETE membrane was characterized to understand membrane performance, and exometabolites from a growing plant root were successfully profiled in a space- and time-resolved manner. This method and device provide a frame-by-frame description of the chemical environment that maps to the physical and biological characteristics of the sample.
Collapse
|
26
|
Regier MC, Olszewski E, Carter CC, Aitchison JD, Kaushansky A, Davis J, Berthier E, Beebe DJ, Stevens KR. Spatial presentation of biological molecules to cells by localized diffusive transfer. Lab Chip 2019; 19:2114-2126. [PMID: 31111131 PMCID: PMC6755031 DOI: 10.1039/c9lc00122k] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Cellular decisions in human development, homeostasis, regeneration, and disease are coordinated in large part by signals that are spatially localized in tissues. These signals are often soluble, such that biomolecules produced by one cell diffuse to receiving cells. To recapitulate soluble factor patterning in vitro, several microscale strategies have been developed. However, these techniques often introduce new variables into cell culture experiments (e.g., fluid flow) or are limited in their ability to pattern diverse solutes in a user-defined manner. To address these challenges, we developed an adaptable method that facilitates spatial presentation of biomolecules across cells in traditional open cultures in vitro. This technique employs device inserts that are placed in standard culture wells, which support localized diffusive pattern transmission through microscale spaces between device features and adherent cells. Devices can be removed and cultures can be returned to standard media following patterning. We use this method to spatially control cell labeling with pattern features ranging in scale from several hundred microns to millimeters and with sequential application of multiple patterns. To better understand the method we investigate relationships between pattern fidelity, device geometry, and consumption and diffusion kinetics using finite element modeling. We then apply the method to spatially defining reporter cell heterogeneity by patterning a small molecule modulator of genetic recombination with the requisite sustained exposure. Finally, we demonstrate use of this method for patterning larger and more slowly diffusing particles by creating focal sites of gene delivery and infection with adenoviral, lentiviral, and Zika virus particles. Thus, our method leverages devices that interface with standard culture vessels to pattern diverse diffusible factors, geometries, exposure dynamics, and recipient cell types, making it well poised for adoption by researchers across various fields of biological research.
Collapse
Affiliation(s)
- Mary C Regier
- Department of Bioengineering, University of Washington, 98195 Seattle, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Goyette PA, Boulais É, Normandeau F, Laberge G, Juncker D, Gervais T. Microfluidic multipoles theory and applications. Nat Commun 2019; 10:1781. [PMID: 30992450 PMCID: PMC6467910 DOI: 10.1038/s41467-019-09740-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 03/14/2019] [Indexed: 11/09/2022] Open
Abstract
Microfluidic multipoles (MFMs) have been realized experimentally and hold promise for "open-space" biological and chemical surface processing. Whereas convective flow can readily be predicted using hydraulic-electrical analogies, the design of advanced microfluidic multipole is constrained by the lack of simple, accurate models to predict mass transport within them. In this work, we introduce the complete solutions to mass transport in multipolar microfluidics based on the iterative conformal mapping of 2D advection-diffusion around a simple edge into dipoles and multipolar geometries, revealing a rich landscape of transport modes. The models are validated experimentally with a library of 3D printed devices and found in excellent agreement. Following a theory-guided design approach, we further ideate and fabricate two classes of spatiotemporally reconfigurable multipolar devices that are used for processing surfaces with time-varying reagent streams, and to realize a multistep automated immunoassay. Overall, the results set the foundations for exploring, developing, and applying open-space microfluidic multipoles.
Collapse
Affiliation(s)
| | - Étienne Boulais
- Department of Engineering Physics, École Polytechnique de Montréal, Montréal, QC, H3T 1J4, Canada
| | - Frédéric Normandeau
- Biomedical Engineering Department and Genome Quebec Innovation Centre, McGill University, Montreal, QC, H3A 0G1, Canada
| | - Gabriel Laberge
- Department of Engineering Physics, École Polytechnique de Montréal, Montréal, QC, H3T 1J4, Canada
| | - David Juncker
- Biomedical Engineering Department and Genome Quebec Innovation Centre, McGill University, Montreal, QC, H3A 0G1, Canada
| | - Thomas Gervais
- Institut de Génie Biomédical, École Polytechnique de Montréal, Montréal, QC, H3T 1J4, Canada. .,Department of Engineering Physics, École Polytechnique de Montréal, Montréal, QC, H3T 1J4, Canada. .,Institut du Cancer de Montréal, Centre de Recherche du Centre Hospitalier de l'Université de Montréal, Montréal, QC, H2X 0C1, Canada.
| |
Collapse
|
28
|
Kashyap A, Fomitcheva Khartchenko A, Pati P, Gabrani M, Schraml P, Kaigala GV. Quantitative microimmunohistochemistry for the grading of immunostains on tumour tissues. Nat Biomed Eng 2019; 3:478-90. [DOI: 10.1038/s41551-019-0386-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 03/07/2019] [Indexed: 02/07/2023]
|
29
|
|
30
|
Arar NM, Pati P, Kashyap A, Khartchenko AF, Goksel O, Kaigala GV, Gabrani M. High-Quality Immunohistochemical Stains Through Computational Assay Parameter Optimization. IEEE Trans Biomed Eng 2019; 66:2952-2963. [PMID: 30762525 DOI: 10.1109/tbme.2019.2899156] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Accurate profiling of tumors using immunohistochemistry (IHC) is essential in cancer diagnosis. The inferences drawn from IHC-stained images depend to a great extent on the quality of immunostaining, which is in turn affected strongly by assay parameters. To optimize assay parameters, the available tissue sample is often limited. Moreover, with current practices in pathology, exploring the entire assay parameter space is not feasible. Thus, the evaluation of IHC stained slides is conventionally a subjective task, in which diagnoses are commonly drawn on images that are suboptimal. In this work, we introduce a framework to analyze IHC staining quality and its sensitivity to process parameters. To that extent, first histopathological sections are segmented automatically. Then, machine learning techniques are employed to extract disease-specific staining quality metrics (SQMs) targeting a quantitative assessment of staining quality. Finally, an approach to efficiently analyze the parameter space is introduced to infer sensitivity to process parameters. We present results on microscale IHC tissue samples of five breast tumor classes, based on disease state and protein expression. A disease-type classification F1-score of 0.82 and a contrast-level classification F1-score of 0.95 were achieved. With the proposed SQMs, an area under the curve of 0.85 was achieved on average over different disease types. Our methodology provides a promising step in automatically evaluating and quantifying staining quality of IHC stained tissue sections, and it can potentially standardize immunostaining across diagnostic laboratories.
Collapse
|
31
|
Duchamp M, Dahoun T, Vaillier C, Arnaud M, Bobisse S, Coukos G, Harari A, Renaud P. Microfluidic device performing on flow study of serial cell–cell interactions of two cell populations. RSC Adv 2019; 9:41066-41073. [PMID: 35540074 PMCID: PMC9076435 DOI: 10.1039/c9ra09504g] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 12/05/2019] [Indexed: 12/14/2022] Open
Abstract
In this study we present a novel microfluidic hydrodynamic trapping device to probe the cell–cell interaction between all cell samples of two distinct populations. We have exploited an hydrodynamic trapping method using microfluidics to immobilize a batch of cells from the first population at specific locations, then relied on hydrodynamic filtering principles, the flowing cells from the second cell population are placed in contact with the trapped ones, through a roll-over mechanism. The rolling cells interact with the serially trapped cells one after the other. The proposed microfluidic phenomenon was characterized with beads. We have shown the validity of our method by detecting the capacity of olfactory receptors to induce adhesion of cell doublets overexpressing these receptors. We report here the first controlled on-flow single cell resolution cell–cell interaction assay in a microfluidic device for future application in cell–cell interactions-based cell library screenings. In this study we present a novel microfluidic hydrodynamic trapping device to probe the cell–cell interaction between all cell samples of two distinct populations.![]()
Collapse
Affiliation(s)
- Margaux Duchamp
- Laboratory of Microsystems LMIS4
- Ecole Polytechnique Fédérale de Lausanne (EPFL)
- Lausanne
- Switzerland
| | - Thamani Dahoun
- Laboratory of Microsystems LMIS4
- Ecole Polytechnique Fédérale de Lausanne (EPFL)
- Lausanne
- Switzerland
| | - Clarisse Vaillier
- Laboratory of Microsystems LMIS4
- Ecole Polytechnique Fédérale de Lausanne (EPFL)
- Lausanne
- Switzerland
| | - Marion Arnaud
- Department of Oncology
- Lausanne University Hospital
- Ludwig Institute for Cancer Research
- University of Lausanne
- Lausanne CH-1066
| | - Sara Bobisse
- Department of Oncology
- Lausanne University Hospital
- Ludwig Institute for Cancer Research
- University of Lausanne
- Lausanne CH-1066
| | - George Coukos
- Department of Oncology
- Lausanne University Hospital
- Ludwig Institute for Cancer Research
- University of Lausanne
- Lausanne CH-1066
| | - Alexandre Harari
- Department of Oncology
- Lausanne University Hospital
- Ludwig Institute for Cancer Research
- University of Lausanne
- Lausanne CH-1066
| | - Philippe Renaud
- Laboratory of Microsystems LMIS4
- Ecole Polytechnique Fédérale de Lausanne (EPFL)
- Lausanne
- Switzerland
| |
Collapse
|
32
|
Huber D, Voith von Voithenberg L, Kaigala G. Fluorescence in situ hybridization (FISH): History, limitations and what to expect from micro-scale FISH? Micro and Nano Engineering 2018; 1:15-24. [DOI: 10.1016/j.mne.2018.10.006] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
33
|
Mao S, Zhang Y, Zhang Q, Lin JM, Uchiyama K. Local surface modification at precise position using a chemical pen. Talanta 2018; 187:246-251. [PMID: 29853042 DOI: 10.1016/j.talanta.2018.05.044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 05/10/2018] [Accepted: 05/11/2018] [Indexed: 11/17/2022]
Abstract
Push-pull cannula system, which was first proposed by Gaddum, has grown to be an important method for the perfusion of brain and region-selective surface treatment. However, reported push-pull cannula systems only concerned on single reagent applications. Microfluidic system was then an exciting tool for multi-reagent treatment on substrate in closed microchannels. Nowadays, it is still a challenge to apply online mixing and reaction for surface pattern in an open environment. Here, we present a novel method using a chemical pen that enables region-selective online chemical reactions for the micro-surface modification/patterning. We utilized this method to fabricate labeling protein array using an online labeling strategy. Moreover, the device was applied for local modification of biomaterials surface by using a three-component reaction at precise position. This tool was the first demonstration of design to perform online reaction of two different reagents on a real solid sample in an open environment. It was demonstrated a useful method for protein array fabrication with online labeled protein.
Collapse
Affiliation(s)
- Sifeng Mao
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, Beijing 100084, China
| | - Yong Zhang
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji 192-0362, Tokyo
| | - Qiang Zhang
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, Beijing 100084, China
| | - Jin-Ming Lin
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, Beijing 100084, China.
| | - Katsumi Uchiyama
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji 192-0362, Tokyo.
| |
Collapse
|
34
|
Affiliation(s)
- Nadya Ostromohov
- IBM Research—Zurich, Säumerstrasse 4, 8803 Rüschlikon, Zurich, Switzerland
- Faculty of Mechanical Engineering, Technion—Israel Institute of Technology, Haifa 3200003, Israel
| | - Deborah Huber
- IBM Research—Zurich, Säumerstrasse 4, 8803 Rüschlikon, Zurich, Switzerland
| | - Moran Bercovici
- Faculty of Mechanical Engineering, Technion—Israel Institute of Technology, Haifa 3200003, Israel
| | - Govind V. Kaigala
- IBM Research—Zurich, Säumerstrasse 4, 8803 Rüschlikon, Zurich, Switzerland
| |
Collapse
|
35
|
Abstract
In this work, we fabricate microfluidic probes (MFPs) in a single step by stereolithographic 3D printing and benchmark their performance with standard MFPs fabricated via glass or silicon micromachining. Two research teams join forces to introduce two independent designs and fabrication protocols, using different equipment. Both strategies adopted are inexpensive and simple (they only require a stereolithography printer) and are highly customizable. Flow characterization is performed by reproducing previously published microfluidic dipolar and microfluidic quadrupolar reagent delivery profiles which are compared to the expected results from numerical simulations and scaling laws. Results show that, for most MFP applications, printer resolution artifacts have negligible impact on probe operation, reagent pattern formation, and cell staining results. Thus, any research group with a moderate resolution (≤100 µm) stereolithography printer will be able to fabricate the MFPs and use them for processing cells, or generating microfluidic concentration gradients. MFP fabrication involved glass and/or silicon micromachining, or polymer micromolding, in every previously published article on the topic. We therefore believe that 3D printed MFPs is poised to democratize this technology. We contribute to initiate this trend by making our CAD files available for the readers to test our "print & probe" approach using their own stereolithographic 3D printers.
Collapse
|
36
|
Abstract
Many in vivo tissue responses begin locally, yet most in vitro stimuli are delivered globally. Microfluidics has a unique ability to provide focal stimulation to tissue samples with precise control over fluid location, flow rate, and composition. However, previous devices utilizing fixed ports beneath the tissue required manual alignment of the tissue over the ports, increasing the risk of mechanical damage. Here we present a novel microfluidic device that allows the user to define the location of fluid delivery to a living tissue slice without manipulating the tissue itself. The device utilized a two-component SlipChip design to create a mobile port beneath the tissue slice. A culture chamber perforated by an array of ports housed a tissue slice and was separated by a layer of fluorocarbon oil from a single delivery port, fed by a microfluidic channel in the movable layer below. We derived and validated a physical model, based on interfacial tension and flow resistance, to predict the conditions under which fluid delivery occurred without leakage into the gap between layers. Aqueous solution was delivered reproducibly to samples of tissue and gel, and the width of the delivery region was controlled primarily by convection. Tissue slice viability was not affected by stimulation on the device. As a proof-of-principle, we showed that live slices of lymph node tissue could be sequentially targeted for precise stimulation. In the future this device may serve as a platform to study the effects of fluid flow in tissues and to perform local drug screening.
Collapse
Affiliation(s)
- Megan A Catterton
- Department of Chemistry, University of Virginia, Charlottesville, VA, USA.
| | | | | |
Collapse
|
37
|
Huber D, Kaigala GV. Rapid micro fluorescence in situ hybridization in tissue sections. Biomicrofluidics 2018; 12:042212. [PMID: 29887936 PMCID: PMC5976495 DOI: 10.1063/1.5023775] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2018] [Accepted: 03/29/2018] [Indexed: 05/04/2023]
Abstract
This paper describes a micro fluorescence in situ hybridization (μFISH)-based rapid detection of cytogenetic biomarkers on formalin-fixed paraffin embedded (FFPE) tissue sections. We demonstrated this method in the context of detecting human epidermal growth factor 2 (HER2) in breast tissue sections. This method uses a non-contact microfluidic scanning probe (MFP), which localizes FISH probes at the micrometer length-scale to selected cells of the tissue section. The scanning ability of the MFP allows for a versatile implementation of FISH on tissue sections. We demonstrated the use of oligonucleotide FISH probes in ethylene carbonate-based buffer enabling rapid hybridization within <1 min for chromosome enumeration and 10-15 min for assessment of the HER2 status in FFPE sections. We further demonstrated recycling of FISH probes for multiple sequential tests using a defined volume of probes by forming hierarchical hydrodynamic flow confinements. This microscale method is compatible with the standard FISH protocols and with the Instant Quality FISH assay and reduces the FISH probe consumption ∼100-fold and the hybridization time 4-fold, resulting in an assay turnaround time of <3 h. We believe that rapid μFISH has the potential of being used in pathology workflows as a standalone method or in combination with other molecular methods for diagnostic and prognostic analysis of FFPE sections.
Collapse
|
38
|
Abstract
![]()
Hydrodynamic phenomena
are ubiquitous in living organisms and can
be used to manipulate cells or emulate physiological microenvironments
experienced in vivo. Hydrodynamic effects influence multiple cellular
properties and processes, including cell morphology, intracellular
processes, cell–cell signaling cascades and reaction kinetics,
and play an important role at the single-cell, multicellular, and
organ level. Selected hydrodynamic effects can also be leveraged to
control mechanical stresses, analyte transport, as well as local temperature
within cellular microenvironments. With a better understanding of
fluid mechanics at the micrometer-length scale and the advent of microfluidic
technologies, a new generation of experimental tools that provide
control over cellular microenvironments and emulate physiological
conditions with exquisite accuracy is now emerging. Accordingly, we
believe that it is timely to assess the concepts underlying hydrodynamic
control of cellular microenvironments and their applications and provide
some perspective on the future of such tools in in vitro cell-culture
models. Generally, we describe the interplay between living cells,
hydrodynamic stressors, and fluid flow-induced effects imposed on
the cells. This interplay results in a broad range of chemical, biological,
and physical phenomena in and around cells. More specifically, we
describe and formulate the underlying physics of hydrodynamic phenomena
affecting both adhered and suspended cells. Moreover, we provide an
overview of representative studies that leverage hydrodynamic effects
in the context of single-cell studies within microfluidic systems.
Collapse
Affiliation(s)
- Deborah Huber
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland.,Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Ali Oskooei
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | - Xavier Casadevall I Solvas
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Andrew deMello
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Govind V Kaigala
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| |
Collapse
|
39
|
Feng S, Nguyen MN, Inglis DW. Microfluidic Droplet Extraction by Hydrophilic Membrane. Micromachines (Basel) 2017; 8:E331. [PMID: 30400521 PMCID: PMC6189788 DOI: 10.3390/mi8110331] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 11/09/2017] [Accepted: 11/15/2017] [Indexed: 11/16/2022]
Abstract
Droplet-based microfluidics are capable of transporting very small amounts of fluid over long distances. This characteristic may be applied to conventional fluid delivery using needles if droplets can be reliably expelled from a microfluidic channel. In this paper, we demonstrate a system for the extraction of water droplets from an oil-phase in a polymer microfluidic device. A hydrophilic membrane with a strong preference for water over oil is integrated into a droplet microfluidic system and observed to allow the passage of the transported aqueous phase droplets while blocking the continuous phase. The oil breakthrough pressure of the membrane was observed to be 250 ± 20 kPa, a much greater pressure than anywhere within the microfluidic channel, thereby eliminating the possibility that oil will leak from the microchannel, a critical parameter if droplet transport is to be used in needle-based drug delivery.
Collapse
Affiliation(s)
- Shilun Feng
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP), Macquarie University, Sydney, NSW 2109, Australia.
| | - Micheal N Nguyen
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
| | - David W Inglis
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP), Macquarie University, Sydney, NSW 2109, Australia.
| |
Collapse
|
40
|
Oskooei A, Kaigala GV. Deep-Reaching Hydrodynamic Flow Confinement: Micrometer-Scale Liquid Localization for Open Substrates With Topographical Variations. IEEE Trans Biomed Eng 2017; 64:1261-1269. [PMID: 28541189 DOI: 10.1109/tbme.2016.2597297] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We present a method for nonintrusive localization and reagent delivery on immersed biological samples with topographical variation on the order of hundreds of micrometers. Our technique, which we refer to as the deep-reaching hydrodynamic flow confinement (DR-HFC), is simple and passive: it relies on a deep-reaching hydrodynamic confinement delivered through a simple microfluidic probe design to perform localized microscale alterations on substrates as deep as 600 μm. Designed to scan centimeter-scale areas of biological substrates, our method passively prevents sample intrusion by maintaining a large gap between the probe and the substrate. The gap prevents collision of the probe and the substrate and reduces the shear stress experienced by the sample. We present two probe designs: linear and annular DR-HFC. Both designs comprise a reagent-injection aperture and aspiration apertures that serve to confine the reagent. We identify the design parameters affecting reagent localization and depth by DR-HFC and study their individual influence on the operation of DR-HFC numerically. Using DR-HFC, we demonstrate localized binding of antihuman immunoglobulin G (IgG) onto an activated substrate at various depths from 50 to 600 μm. DR-HFC provides a readily implementable approach for noninvasive processing of biological samples applicable to the next generation of diagnostic and bioanalytical devices.
Collapse
|
41
|
Huang CM, Zhu Y, Jin DQ, Kelly RT, Fang Q. Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip. Anal Chem 2017; 89:9009-9016. [PMID: 28780855 DOI: 10.1021/acs.analchem.7b01679] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dry-spot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.
Collapse
Affiliation(s)
- Cong-Min Huang
- Institute of Microanalytical Systems, Department of Chemistry and Innovation Center for Cell Signaling Network, Zhejiang University , Hangzhou, 310058, China
| | - Ying Zhu
- Institute of Microanalytical Systems, Department of Chemistry and Innovation Center for Cell Signaling Network, Zhejiang University , Hangzhou, 310058, China
| | - Di-Qiong Jin
- Institute of Microanalytical Systems, Department of Chemistry and Innovation Center for Cell Signaling Network, Zhejiang University , Hangzhou, 310058, China
| | - Ryan T Kelly
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory , Richland, Washington 99354, United States
| | - Qun Fang
- Institute of Microanalytical Systems, Department of Chemistry and Innovation Center for Cell Signaling Network, Zhejiang University , Hangzhou, 310058, China
| |
Collapse
|
42
|
Mao S, Zhang Y, Zhang W, Zeng H, Nakajima H, Lin JM, Uchiyama K. Convection-Diffusion Layer in an “Open Space” for Local Surface Treatment and Microfabrication using a Four-Aperture Microchemical Pen. Chemphyschem 2017; 18:2357-2363. [DOI: 10.1002/cphc.201700577] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Indexed: 01/18/2023]
Affiliation(s)
- Sifeng Mao
- Department of Chemistry; Beijing Key Laboratory of Microanalytical Methods and Instrumentation; The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology; Tsinghua University; Beijing 100084 China
- Department of Applied Chemistry; Graduate School of Urban Environmental Sciences; Tokyo Metropolitan University; Minamiohsawa Hachioji Tokyo 192-0397 Japan
| | - Yong Zhang
- Department of Applied Chemistry; Graduate School of Urban Environmental Sciences; Tokyo Metropolitan University; Minamiohsawa Hachioji Tokyo 192-0397 Japan
| | - Weifei Zhang
- Department of Applied Chemistry; Graduate School of Urban Environmental Sciences; Tokyo Metropolitan University; Minamiohsawa Hachioji Tokyo 192-0397 Japan
| | - Hulie Zeng
- Department of Applied Chemistry; Graduate School of Urban Environmental Sciences; Tokyo Metropolitan University; Minamiohsawa Hachioji Tokyo 192-0397 Japan
| | - Hizuru Nakajima
- Department of Applied Chemistry; Graduate School of Urban Environmental Sciences; Tokyo Metropolitan University; Minamiohsawa Hachioji Tokyo 192-0397 Japan
| | - Jin-Ming Lin
- Department of Chemistry; Beijing Key Laboratory of Microanalytical Methods and Instrumentation; The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology; Tsinghua University; Beijing 100084 China
| | - Katsumi Uchiyama
- Department of Applied Chemistry; Graduate School of Urban Environmental Sciences; Tokyo Metropolitan University; Minamiohsawa Hachioji Tokyo 192-0397 Japan
| |
Collapse
|
43
|
Pompano RR, Chiang AH, Kastrup CJ, Ismagilov RF. Conceptual and Experimental Tools to Understand Spatial Effects and Transport Phenomena in Nonlinear Biochemical Networks Illustrated with Patchy Switching. Annu Rev Biochem 2017; 86:333-356. [PMID: 28654324 PMCID: PMC10852032 DOI: 10.1146/annurev-biochem-060815-014207] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Many biochemical systems are spatially heterogeneous and exhibit nonlinear behaviors, such as state switching in response to small changes in the local concentration of diffusible molecules. Systems as varied as blood clotting, intracellular calcium signaling, and tissue inflammation are all heavily influenced by the balance of rates of reaction and mass transport phenomena including flow and diffusion. Transport of signaling molecules is also affected by geometry and chemoselective confinement via matrix binding. In this review, we use a phenomenon referred to as patchy switching to illustrate the interplay of nonlinearities, transport phenomena, and spatial effects. Patchy switching describes a change in the state of a network when the local concentration of a diffusible molecule surpasses a critical threshold. Using patchy switching as an example, we describe conceptual tools from nonlinear dynamics and chemical engineering that make testable predictions and provide a unifying description of the myriad possible experimental observations. We describe experimental microfluidic and biochemical tools emerging to test conceptual predictions by controlling transport phenomena and spatial distribution of diffusible signals, and we highlight the unmet need for in vivo tools.
Collapse
Affiliation(s)
- Rebecca R Pompano
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904;
| | - Andrew H Chiang
- Department of Chemistry and Institute for Biophysical Dynamics, The University of Chicago, Chicago, Illinois 60637;
| | - Christian J Kastrup
- Michael Smith Laboratories and Department of Biochemistry and Molecular Biology, University of British Columbia, Vancouver, British Columbia V6T 1Z4, Canada;
| | - Rustem F Ismagilov
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125;
| |
Collapse
|
44
|
Cors JF, Kashyap A, Fomitcheva Khartchenko A, Schraml P, Kaigala GV. Tissue lithography: Microscale dewaxing to enable retrospective studies on formalin-fixed paraffin-embedded (FFPE) tissue sections. PLoS One 2017; 12:e0176691. [PMID: 28493979 DOI: 10.1371/journal.pone.0176691] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 04/16/2017] [Indexed: 01/01/2023] Open
Abstract
We present a new concept, termed tissue lithography (TL), and its implementation which enables retrospective studies on formalin-fixed paraffin-embedded tissue sections. Tissue lithography uses a microfluidic probe to remove microscale areas of the paraffin layer on formalin-fixed paraffin-embedded biopsy samples. Current practices in sample utilization for research and diagnostics require complete deparaffinization of the sample prior to molecular testing. This imposes strong limitations in terms of the number of tests as well as the time when they can be performed on a single sample. Microscale dewaxing lifts these constraints by permitting deprotection of a fraction of a tissue for testing while keeping the remaining of the sample intact for future analysis. After testing, the sample can be sent back to storage instead of being discarded, as is done in standard workflows. We achieve this microscale dewaxing by hydrodynamically confining nanoliter volumes of xylene on top of the sample with a probe head. We demonstrate micrometer-scale, chromogenic and fluorescence-based immunohistochemistry against multiple biomarkers (p53, CD45, HER2 and β-actin) on tonsil and breast tissue sections and microarrays. We achieve stain patterns as small as 100 μm × 50 μm as well as multiplexed immunostaining within a single tissue microarray core with a 20-fold time reduction for local dewaxing as compared to standard protocols. We also demonstrate a 10-fold reduction in the rehydration time, leading to lower processing times between different stains. We further show the potential of TL for retrospective studies by sequentially dewaxing and staining four individual cores within the same tissue microarray over four consecutive days. By combining tissue lithography with the concept of micro-immunohistochemistry, we implement each step of the IHC protocol—dewaxing, rehydration and staining—with the same microfluidic probe head. Tissue lithography brings a new level of versatility and flexibility in sample processing and budgeting in biobanks, which may alleviate current sample limitations for retrospective studies in biomarker discovery and drug screening.
Collapse
|
45
|
|
46
|
Horayama M, Shinha K, Kabayama K, Fujii T, Kimura H. Spatial Chemical Stimulation Control in Microenvironment by Microfluidic Probe Integrated Device for Cell-Based Assay. PLoS One 2016; 11:e0168158. [PMID: 27930750 PMCID: PMC5145238 DOI: 10.1371/journal.pone.0168158] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Accepted: 11/24/2016] [Indexed: 12/15/2022] Open
Abstract
Cell—cell interactions play an important role in the development and function of multicellular organisms. To investigate these interactions in detail, it is necessary to evaluate the behavior of a cell population when the minimum number of cells in the population is stimulated by some chemical factors. We propose a microfluidic device integrated with microfluidic probe (MFP) functionality; this device is capable of imparting a chemical stimulus to cells within a microenvironment, for cell-based assays. The device contains MFP channels at the walls of the cell culture microchannels, and it can control a localized chemical stimulation area at the scale of a single cell to a few cells using MFP fluid control in a microspace. The results of a finite element method-based simulation indicated that it is possible to control the chemical stimulation area at the scale of a single cell to a few cells by optimizing the MFP channel apex width and the flow ratio. In addition, localized cell staining was demonstrated successfully using a spatial chemical stimulus. We confirmed the device functionality as a novel cell-based assay tool. We succeeded in performing localized cell collection using this method, which suggested that the single cell analysis of a cell monolayer that is subjected to a specific chemical stimulus is possible. The method proposed in this paper can contribute significantly to the fields of cell biology and drug development.
Collapse
Affiliation(s)
- Masayuki Horayama
- Department of Mechanical Engineering, Tokai University, Hiratsuka, Kanagawa, Japan
| | - Kenta Shinha
- Department of Mechanical Engineering, Tokai University, Hiratsuka, Kanagawa, Japan
| | - Kazuya Kabayama
- Department of Chemistry, Osaka University, Toyonaka, Osaka, Japan
- Micro/Nano Technology Center, Tokai University, Hiratsuka, Kanagawa, Japan
| | - Teruo Fujii
- Institute of Industrial Science, The University of Tokyo, Meguro, Tokyo, Japan
| | - Hiroshi Kimura
- Department of Mechanical Engineering, Tokai University, Hiratsuka, Kanagawa, Japan
- Micro/Nano Technology Center, Tokai University, Hiratsuka, Kanagawa, Japan
- * E-mail:
| |
Collapse
|
47
|
Abstract
We here present a micrometer-scale implementation of fluorescence in situ hybridization that we term μFISH. This μFISH implementation makes use of a non-contact scanning probe technology, namely, a microfluidic probe (MFP) that hydrodynamically shapes nanoliter volumes of liquid on a surface with micrometer resolution. By confining FISH probes at the tip of this microfabricated scanning probe, we locally exposed approximately 1000 selected MCF-7 cells of a monolayer to perform incubation of probes - the rate-limiting step in conventional FISH. This method is compatible with the standard workflow of conventional FISH, allows re-budgeting of the sample for various tests, and results in a ~ 15-fold reduction in probe consumption. The continuous flow of probes and shaping liquid on these selected cells resulted in a 120-fold reduction of the hybridization time compared with the standard protocol (3 min vs. 6 h) and efficient rinsing, thereby shortening the total FISH assay time for centromeric probes. We further demonstrated spatially multiplexed μFISH, enabling the use of spectrally equivalent probes for detailed and real-time analysis of a cell monolayer, which paves the way towards rapid and automated multiplexed FISH on standard cytological supports.
Collapse
Affiliation(s)
- D Huber
- IBM Research - Zurich, Säumerstrasse 4, 8803, Rüschlikon, Switzerland
| | - J Autebert
- IBM Research - Zurich, Säumerstrasse 4, 8803, Rüschlikon, Switzerland
| | - G V Kaigala
- IBM Research - Zurich, Säumerstrasse 4, 8803, Rüschlikon, Switzerland.
| |
Collapse
|
48
|
Mao S, Sato C, Suzuki Y, Yang J, Zeng H, Nakajima H, Yang M, Lin JM, Uchiyama K. Microchemical Pen: An Open Microreactor for Region-Selective Surface Modification. Chemphyschem 2016; 17:3155-3159. [PMID: 27505180 DOI: 10.1002/cphc.201600857] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Indexed: 11/05/2022]
Abstract
Various micro surface-modification approaches including photolithography, dip-pen lithography and ink-jet systems have been developed and used to extend the functionalities of solid surfaces. While those approaches work in the "open space", push-pull systems which work in solutions have recently drawn considerable attention. However, the confining flows performed by push-pull systems have realized only the dispense process, while microscale, region-selective chemical reactions have remained unattainable. This study reports a microchemical pen that enables region-selective chemical reactions for the micro surface modification/patterning. The chemical pen is based on the principle of microfluidic laminar flows and the resulting mixing of reagents by the mutual diffusion. The tiny diffusion layer performs as the working region. This report represents the first demonstration of an open microreactor in which two different reagents react on a real solid sample. The multifunctional characteristics of the microchemical pen are confirmed by different types of reactions in many research areas, including inorganic chemistry, polymer science, electrochemistry and biological sample treatment.
Collapse
Affiliation(s)
- Sifeng Mao
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan
| | - Chiho Sato
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan
| | - Yuma Suzuki
- Department of Human Mechatronics Systems, Graduate School of System Design, Tokyo Metropolitan University, Hino-shi, Tokyo, 191-0065, Japan
| | - Jianmin Yang
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan
| | - Hulie Zeng
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan
| | - Hizuru Nakajima
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan
| | - Ming Yang
- Department of Human Mechatronics Systems, Graduate School of System Design, Tokyo Metropolitan University, Hino-shi, Tokyo, 191-0065, Japan
| | - Jin-Ming Lin
- Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Katsumi Uchiyama
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan.
| |
Collapse
|
49
|
Abstract
We present a device and method for selective chemical interactions with immersed substrates at the centimeter-scale. Our implementations enable both, sequential and simultaneous delivery of multiple reagents to a substrate, as well as the creation of gradients of reagents on surfaces. The method is based on localizing submicroliter volumes of liquids on an immersed surface with a microfluidic probe (MFP) using a principle termed hydrodynamic flow confinement (HFC). We here show spatially defined, multiplexed surface interactions while benefiting from the probe capabilities such as non-contact scanning operation and convection-enhanced reaction kinetics. Three-layer glass-Si-glass probes were developed to implement slit-aperture and aperture-array designs. Analytical and numerical analysis helped to establish probe designs and operating parameters. Using these probes, we performed immunohistochemical analysis on individual cores of a human breast-cancer tissue microarray. We applied α-p53 antibodies on a 2 mm diameter core within 2.5 min using a slit-aperture probe (HFC dimension: 0.3 mm × 1.2 mm). Further, multiplexed treatment of a tissue core with α-p53 and α-β-actin antibodies was performed using four adjacent HFCs created with an aperture-array probe (HFC dimension: 4 × 0.3 mm × 0.25 mm). The ability of these devices and methods to perform multiplexed assays, present sequentially different liquids on surfaces, and interact with surfaces at the centimeter-scale will likely spur new and efficient surface assays.
Collapse
|
50
|
Abstract
The microfluidic probe (MFP) facilitates performing local chemistry on biological substrates by confining nanoliter volumes of liquids. Using one particular implementation of the MFP, the hierarchical hydrodynamic flow confinement (hHFC), multiple liquids are simultaneously brought in contact with a substrate. Local chemical action and liquid shaping using the hHFC, is exploited to create cell patterns by locally lysing and removing cells. By utilizing the scanning ability of the MFP, user-defined patterns of cell monolayers are created. This protocol enables rapid, real-time and spatially controlled cell patterning, which can allow selective cell-cell and cell-matrix interaction studies.
Collapse
|