1
|
Zoheir AE, Stolle C, Rabe KS. Microfluidics for adaptation of microorganisms to stress: design and application. Appl Microbiol Biotechnol 2024; 108:162. [PMID: 38252163 PMCID: PMC10803453 DOI: 10.1007/s00253-024-13011-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/22/2023] [Accepted: 01/11/2024] [Indexed: 01/23/2024]
Abstract
Microfluidic systems have fundamentally transformed the realm of adaptive laboratory evolution (ALE) for microorganisms by offering unparalleled control over environmental conditions, thereby optimizing mutant generation and desired trait selection. This review summarizes the substantial influence of microfluidic technologies and their design paradigms on microbial adaptation, with a primary focus on leveraging spatial stressor concentration gradients to enhance microbial growth in challenging environments. Specifically, microfluidic platforms tailored for scaled-down ALE processes not only enable highly autonomous and precise setups but also incorporate novel functionalities. These capabilities encompass fostering the growth of biofilms alongside planktonic cells, refining selection gradient profiles, and simulating adaptation dynamics akin to natural habitats. The integration of these aspects enables shaping phenotypes under pressure, presenting an unprecedented avenue for developing robust, stress-resistant strains, a feat not easily attainable using conventional ALE setups. The versatility of these microfluidic systems is not limited to fundamental research but also offers promising applications in various areas of stress resistance. As microfluidic technologies continue to evolve and merge with cutting-edge methodologies, they possess the potential not only to redefine the landscape of microbial adaptation studies but also to expedite advancements in various biotechnological areas. KEY POINTS: • Microfluidics enable precise microbial adaptation in controlled gradients. • Microfluidic ALE offers insights into stress resistance and distinguishes between resistance and persistence. • Integration of adaptation-influencing factors in microfluidic setups facilitates efficient generation of stress-resistant strains.
Collapse
Affiliation(s)
- Ahmed E Zoheir
- Department of Genetics and Cytology, Biotechnology Research Institute, National Research Centre (NRC), 33 El Buhouth St., Dokki, Cairo, 12622, Egypt
| | - Camilla Stolle
- Institute for Biological Interfaces 1 (IBG-1), Biomolecular Micro- and Nanostructures, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany
| | - Kersten S Rabe
- Institute for Biological Interfaces 1 (IBG-1), Biomolecular Micro- and Nanostructures, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
| |
Collapse
|
2
|
Chen C, Li P, Guo T, Chen S, Xu D, Chen H. Generation of Dynamic Concentration Profile Using A Microfluidic Device Integrating Pneumatic Microvalves. Biosensors (Basel) 2022; 12:bios12100868. [PMID: 36291005 PMCID: PMC9599525 DOI: 10.3390/bios12100868] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/08/2022] [Accepted: 10/09/2022] [Indexed: 06/12/2023]
Abstract
Generating and maintaining the concentration dilutions of diffusible molecules in microchannels is critical for high-throughput chemical and biological analysis. Conventional serial network microfluidic technologies can generate high orders of arbitrary concentrations by a predefined microchannel network. However, a previous design requires a large occupancy area and is unable to dynamically generate different profiles in the same chip, limiting its applications. This study developed a microfluidic device enabling dynamic variations of both the concentration in the same channel and the concentration distribution in multiple channels by adjusting the flow resistance using programmable pneumatic microvalves. The key component (the pneumatic microvalve) allowed dynamic adjustment of the concentration profile but occupied a tiny space. Additionally, a Matlab program was developed to calculate the flow rates and flow resistance of various sections of the device, which provided theoretical guidance for dimension design. In silico investigations were conducted to evaluate the microvalve deformation with widths from 100 to 300 µm and membrane thicknesses of 20 and 30 µm under the activation pressures between 0 and 2000 mbar. The flow resistance of the deformed valve was studied both numerically and experimentally and an empirical model for valve flow resistance with the form of Rh=aebP was proposed. Afterward, the fluid flow in the valve region was characterized using Micro PIV to further demonstrate the adjustment mechanism of the flow resistance. Then, the herringbone structures were employed for fast mixing to allow both quick variation of concentration and minor space usage of the channel network. Finally, an empirical formula-supported computational program was developed to provide the activation pressures required for the specific concentration profile. Both linear (Ck = -0.2k + 1) and nonlinear (Ck = (110)k) concentration distribution in four channels were varied using the same device by adjusting microvalves. The device demonstrated the capability to control the concentration profile dynamically in a small space, offering superior application potentials in analytical chemistry, drug screening, and cell biology research.
Collapse
Affiliation(s)
- Chang Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China
| | - Panpan Li
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW 2052, Australia
| | - Siyuan Chen
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
| | - Dong Xu
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
| | - Huaying Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China
| |
Collapse
|
3
|
Shirai H, Ito C, Tsukada K. pH-taxis drives aerobic bacteria in duodenum to migrate into the pancreas with tumors. Sci Rep 2022; 12:1783. [PMID: 35110595 DOI: 10.1038/s41598-022-05554-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 01/13/2022] [Indexed: 01/07/2023] Open
Abstract
As oral or intestinal bacteria have been found in pancreatic cystic fluid and tumors, understanding bacterial migration from the duodenum into the pancreas via hepato-pancreatic duct is critical. Mathematical models of migration of aerobic bacteria from the duodenum to the pancreas with tumors were developed. Additionally, the bacterial distributions under the pH gradient and those under flow were measured in double-layer flow based microfluidic device and T-shaped cylinders. Migration of aerobic bacteria from the duodenum into pancreas is counteracted by bile and pancreatic juice flow but facilitated by pH-taxis from acidic duodenum fluid toward more favorable slightly alkaline pH in pancreatic juice. Additionally, the reduced flow velocity in cancer patients, due to compressed pancreatic duct by solid tumor, facilitates migration. Moreover, measured distribution of GFP E. coli under the pH gradient in a microfluidic device validated pH-tactic behaviors. Furthermore, Pseudomonas fluorescens in hydrochloride solution, but not in bicarbonate solution, migrated upstream against bicarbonate flow of > 20 μm/s, with an advancement at approximately 50 μm/s.
Collapse
|
4
|
Dai B, Long Y, Wu J, Huang S, Zhao Y, Zheng L, Tao C, Guo S, Lin F, Fu Y, Zhang D, Zhuang S. Generation of flow and droplets with an ultra-long-range linear concentration gradient. Lab Chip 2021; 21:4390-4400. [PMID: 34704106 DOI: 10.1039/d1lc00749a] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In the chemical and biological fields, the creation of concentration gradient microenvironments is an important approach for many applications, such as crystal growth and drug screening. Although many concentration gradient generators have been demonstrated, current generators can hardly produce ultra-long linear concentration gradients. In this paper, we propose a concentration-gradient flow/droplet generator which consists of a microfluidic flow switch, a cavity array for stage-by-stage concentration dilution, and an optional T-junction for droplet formation. The generator can realize an ultra-long continuously-varying concentration gradient along the flow direction. Generation of a 38 mm concentration gradient was demonstrated. The length can be further extended by enlarging the capacity of the cavities and increasing the number of the stages. The concentration gradient showed high linearity in the range of 10% to 90%. Moreover, cyclic generation of a concentration gradient flow and droplets with different concentrations was realized by the generator. In a demonstration of drug screening, the generator was employed to produce paclitaxel in different concentrations. A negative correlation between the 4T1 cell viability and the paclitaxel concentration was observed after the treatment. We envision that the concentration gradient generator will be a promising candidate for various drug screening applications.
Collapse
Affiliation(s)
- Bo Dai
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Yan Long
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Jiandong Wu
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Shaoqi Huang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Yuan Zhao
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Lulu Zheng
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Chunxian Tao
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Shiwei Guo
- Department of Hepatobiliary Pancreatic Surgery, Changhai Hospital, Naval Military Medical University, Shanghai 200433, China
| | - Francis Lin
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada.
| | - Yongfeng Fu
- Department of Laboratory Medicine, Shanghai Cancer Center, Fudan University, Shanghai, 200032, China.
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Songlin Zhuang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| |
Collapse
|
5
|
Abstract
Enzyme-based systems have been shown to undergo chemotactic motion in response to their substrate gradient. This phenomenon has been exploited to direct the motion of enzymes and enzyme-attached particles to specific locations in space. Here, we propose a new kinetic model to analyze the directional movement of an ensemble of protein molecules in response to a gradient of the ligand. We also formulate a separate model to probe the motion of enzyme molecules in response to a gradient of the substrate under catalytic conditions. The only input for the new enzymatic model is the Michaelis-Menten constant which is the relevant measurable constant for enzymatic reactions. We show how our model differs from previously proposed models in a significant manner. For both binding and catalytic reactions, a net movement up the ligand/substrate gradient is predicted when the diffusivity of the ligand/substrate-bound protein is lower than that of the unbound protein (positive chemotaxis). Conversely, movement down the ligand/substrate gradient is expected when the diffusivity of the ligand/substrate-bound protein is higher than that of the unbound protein (negative chemotaxis). However, there is no net movement of protein/enzyme when the diffusivities of the bound and free species are equal. The work underscores the critical importance of measuring the diffusivity of the bound protein and comparing it with that of the free protein.
Collapse
Affiliation(s)
- Niladri Sekhar Mandal
- Department of Chemical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Ayusman Sen
- Department of Chemical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Department of Chemistry, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
6
|
Neves ER, Harley BAC, Pedron S. Microphysiological systems to study tumor-stroma interactions in brain cancer. Brain Res Bull 2021; 174:220-229. [PMID: 34166771 PMCID: PMC8324563 DOI: 10.1016/j.brainresbull.2021.06.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 05/17/2021] [Accepted: 06/15/2021] [Indexed: 12/15/2022]
Abstract
Brain tumors still lack effective treatments, and the mechanisms of tumor progression and therapeutic resistance are unclear. Multiple parameters affect cancer prognosis (e.g., type and grade, age, location, size, and genetic mutations) and election of suitable treatments is based on preclinical models and clinical data. However, most candidate drugs fail in human trials due to inefficacy. Cell lines and tissue culture plates do not provide physiologically relevant environments, and animal models are not able to adequately mimic characteristics of disease in humans. Therefore, increasing technological advances are focusing on in vitro and computational modeling to increase the throughput and predicting capabilities of preclinical systems. The extensive use of these therapeutic agents requires a more profound understanding of the tumor-stroma interactions, including neural tissue, extracellular matrix, blood-brain barrier, astrocytes and microglia. Microphysiological brain tumor models offer physiologically relevant vascularized 'minitumors' that can help deciphering disease mechanisms, accelerating the drug discovery and predicting patient's response to anticancer treatments. This article reviews progress in tumor-on-a-chip platforms that are designed to comprehend the particular roles of stromal cells in the brain tumor microenvironment.
Collapse
Affiliation(s)
- Edward R Neves
- Department of Chemical and Biomolecular Engineering, Carl R Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Brendan A C Harley
- Department of Chemical and Biomolecular Engineering, Carl R Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Sara Pedron
- Department of Chemical and Biomolecular Engineering, Carl R Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
| |
Collapse
|
7
|
Khan A, Smith NM, Tullier MP, Roberts BS, Englert D, Pojman JA, Melvin AT. Development of a Flow-free Gradient Generator Using a Self-Adhesive Thiol-acrylate Microfluidic Resin/Hydrogel (TAMR/H) Hybrid System. ACS Appl Mater Interfaces 2021; 13:26735-26747. [PMID: 34081856 PMCID: PMC8289190 DOI: 10.1021/acsami.1c04771] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Accepted: 05/21/2021] [Indexed: 06/12/2023]
Abstract
Microfluidic gradient generators have been used to study cellular migration, growth, and drug response in numerous biological systems. One type of device combines a hydrogel and polydimethylsiloxane (PDMS) to generate "flow-free" gradients; however, their requirements for either negative flow or external clamps to maintain fluid-tight seals between the two layers have restricted their utility among broader applications. In this work, a two-layer, flow-free microfluidic gradient generator was developed using thiol-ene chemistry. Both rigid thiol-acrylate microfluidic resin (TAMR) and diffusive thiol-acrylate hydrogel (H) layers were synthesized from commercially available monomers at room temperature and pressure using a base-catalyzed Michael addition. The device consisted of three parallel microfluidic channels negatively imprinted in TAMR layered on top of the thiol-acrylate hydrogel to facilitate orthogonal diffusion of chemicals to the direction of flow. Upon contact, these two layers formed fluid-tight channels without any external pressure due to a strong adhesive interaction between the two layers. The diffusion of molecules through the TAMR/H system was confirmed both experimentally (using fluorescent microscopy) and computationally (using COMSOL). The performance of the TAMR/H system was compared to a conventional PDMS/agarose device with a similar geometry by studying the chemorepulsive response of a motile strain of GFP-expressing Escherichia coli. Population-based analysis confirmed a similar migratory response of both wild-type and mutant E. coli in both of the microfluidic devices. This confirmed that the TAMR/H hybrid system is a viable alternative to traditional PDMS-based microfluidic gradient generators and can be used for several different applications.
Collapse
Affiliation(s)
- Anowar
H. Khan
- Department
of Chemistry, Louisiana State University, Baton Rouge 70803, Louisiana, United States
| | - Noah Mulherin Smith
- Cain
Department of Chemical Engineering, Louisiana
State University, Baton Rouge 70803, Louisiana, United States
| | - Michael P. Tullier
- Department
of Chemistry, Louisiana State University, Baton Rouge 70803, Louisiana, United States
| | - B. Seth Roberts
- Cain
Department of Chemical Engineering, Louisiana
State University, Baton Rouge 70803, Louisiana, United States
| | - Derek Englert
- Chemical
and Materials Engineering, University of
Kentucky, Paducah 42002, Kentucky, United States
| | - John A. Pojman
- Department
of Chemistry, Louisiana State University, Baton Rouge 70803, Louisiana, United States
| | - Adam T. Melvin
- Cain
Department of Chemical Engineering, Louisiana
State University, Baton Rouge 70803, Louisiana, United States
| |
Collapse
|
8
|
Yang L, Pijuan-Galito S, Rho HS, Vasilevich AS, Eren AD, Ge L, Habibović P, Alexander MR, de Boer J, Carlier A, van Rijn P, Zhou Q. High-Throughput Methods in the Discovery and Study of Biomaterials and Materiobiology. Chem Rev 2021; 121:4561-4677. [PMID: 33705116 PMCID: PMC8154331 DOI: 10.1021/acs.chemrev.0c00752] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Indexed: 02/07/2023]
Abstract
The complex interaction of cells with biomaterials (i.e., materiobiology) plays an increasingly pivotal role in the development of novel implants, biomedical devices, and tissue engineering scaffolds to treat diseases, aid in the restoration of bodily functions, construct healthy tissues, or regenerate diseased ones. However, the conventional approaches are incapable of screening the huge amount of potential material parameter combinations to identify the optimal cell responses and involve a combination of serendipity and many series of trial-and-error experiments. For advanced tissue engineering and regenerative medicine, highly efficient and complex bioanalysis platforms are expected to explore the complex interaction of cells with biomaterials using combinatorial approaches that offer desired complex microenvironments during healing, development, and homeostasis. In this review, we first introduce materiobiology and its high-throughput screening (HTS). Then we present an in-depth of the recent progress of 2D/3D HTS platforms (i.e., gradient and microarray) in the principle, preparation, screening for materiobiology, and combination with other advanced technologies. The Compendium for Biomaterial Transcriptomics and high content imaging, computational simulations, and their translation toward commercial and clinical uses are highlighted. In the final section, current challenges and future perspectives are discussed. High-throughput experimentation within the field of materiobiology enables the elucidation of the relationships between biomaterial properties and biological behavior and thereby serves as a potential tool for accelerating the development of high-performance biomaterials.
Collapse
Affiliation(s)
- Liangliang Yang
- University
of Groningen, W. J. Kolff Institute for Biomedical Engineering and
Materials Science, Department of Biomedical Engineering, University Medical Center Groningen, A. Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Sara Pijuan-Galito
- School
of Pharmacy, Biodiscovery Institute, University
of Nottingham, University Park, Nottingham NG7 2RD, U.K.
| | - Hoon Suk Rho
- Department
of Instructive Biomaterials Engineering, MERLN Institute for Technology-Inspired
Regenerative Medicine, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Aliaksei S. Vasilevich
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MB Eindhoven, The Netherlands
| | - Aysegul Dede Eren
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MB Eindhoven, The Netherlands
| | - Lu Ge
- University
of Groningen, W. J. Kolff Institute for Biomedical Engineering and
Materials Science, Department of Biomedical Engineering, University Medical Center Groningen, A. Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Pamela Habibović
- Department
of Instructive Biomaterials Engineering, MERLN Institute for Technology-Inspired
Regenerative Medicine, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Morgan R. Alexander
- School
of Pharmacy, Boots Science Building, University
of Nottingham, University Park, Nottingham NG7 2RD, U.K.
| | - Jan de Boer
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MB Eindhoven, The Netherlands
| | - Aurélie Carlier
- Department
of Cell Biology-Inspired Tissue Engineering, MERLN Institute for Technology-Inspired
Regenerative Medicine, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Patrick van Rijn
- University
of Groningen, W. J. Kolff Institute for Biomedical Engineering and
Materials Science, Department of Biomedical Engineering, University Medical Center Groningen, A. Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Qihui Zhou
- Institute
for Translational Medicine, Department of Stomatology, The Affiliated
Hospital of Qingdao University, Qingdao
University, Qingdao 266003, China
| |
Collapse
|
9
|
Abstract
The integration of membranes in microfluidic devices has been extensively exploited for various chemical engineering and bioengineering applications over the past few decades. To augment the applicability of membrane-integrated microfluidic platforms for biomedical and tissue engineering studies, a biologically friendly fabrication process with naturally occurring materials is highly desired. The in situ preparation of membranes involving interfacial reactions between parallel laminar flows in microfluidic networks, known as the flow-assembly technique, is one of the most biocompatible approaches. Membranes of many types with flexible geometries have been successfully assembled inside complex microchannels using this facile and versatile flow-assembly approach. Chitosan is a naturally abundant polysaccharide known for its pronounced biocompatibility, biodegradability, good mechanical stability, ease of modification and processing, and film-forming ability under near-physiological conditions. Chitosan membranes assembled by flows in microfluidics are freestanding, robust, semipermeable, and well-aligned in microstructure, and show high affinity to bioactive reagents and biological components (e.g. biomolecules, nanoparticles, or cells) that provide facile biological functionalization of microdevices. Here, we discuss the recent developments and optimizations in the flow-assembly of chitosan membranes and chitosan-based membranes in microfluidics. Furthermore, we recapitulate the applications of the chitosan membrane-integrated microfluidic platforms dedicated to biology, biochemistry, and drug release fields, and envision the future developments of this important platform with versatile functions.
Collapse
Affiliation(s)
- Khanh L Ly
- Department of Biomedical Engineering, The Catholic University of America, Washington, DC 20064, USA
| | | | | | | |
Collapse
|
10
|
Möller N, Liebchen B, Palberg T. Shaping the gradients driving phoretic micro-swimmers: influence of swimming speed, budget of carbonic acid and environment. Eur Phys J E Soft Matter 2021; 44:41. [PMID: 33759011 PMCID: PMC7987694 DOI: 10.1140/epje/s10189-021-00026-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 01/22/2021] [Indexed: 05/07/2023]
Abstract
pH gradient-driven modular micro-swimmers are investigated as a model for a large variety of quasi-two-dimensional chemi-phoretic self-propelled entities. Using three-channel micro-photometry, we obtain a precise large field mapping of pH at a spatial resolution of a few microns and a pH resolution of [Formula: see text] units for swimmers of different velocities propelling on two differently charged substrates. We model our results in terms of solutions of the three-dimensional advection-diffusion equation for a 1:1 electrolyte, i.e. carbonic acid, which is produced by ion exchange and consumed by equilibration with dissolved [Formula: see text]. We demonstrate the dependence of gradient shape and steepness on swimmer speed, diffusivity of chemicals, as well as the fuel budget. Moreover, we experimentally observe a subtle, but significant feedback of the swimmer's immediate environment in terms of a substrate charge-mediated solvent convection. We discuss our findings in view of different recent results from other micro-fluidic or active matter investigations. We anticipate that they are relevant for quantitative modelling and targeted applications of diffusio-phoretic flows in general and artificial micro-swimmers in particular.
Collapse
Affiliation(s)
- Nadir Möller
- Institute of Condensed Matter Physics, Johannes Gutenberg Universität, Staudinger Weg 7, 55128, Mainz, Germany.
- Max Planck Graduade Center, Institute of Physics, Johannes Gutenberg Universität, Staudinger Weg 7, 55128, Mainz, Germany.
| | - Benno Liebchen
- Institute for Condensed Matter Physics, Technische Universität Darmstadt, Hochschulstr. 8, 64289, Darmstadt, Germany
| | - Thomas Palberg
- Institute of Condensed Matter Physics, Johannes Gutenberg Universität, Staudinger Weg 7, 55128, Mainz, Germany
| |
Collapse
|
11
|
Zoheir AE, Späth GP, Niemeyer CM, Rabe KS. Microfluidic Evolution-On-A-Chip Reveals New Mutations that Cause Antibiotic Resistance. Small 2021; 17:e2007166. [PMID: 33458946 DOI: 10.1002/smll.202007166] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/22/2020] [Indexed: 06/12/2023]
Abstract
Microfluidic devices can mimic naturally occurring microenvironments and create microbial population heterogeneities ranging from planktonic cells to biofilm states. The exposure of such populations to spatially organized stress gradients can promote their adaptation into complex phenotypes, which are otherwise difficult to achieve with conventional experimental setups. Here a microfluidic chip that employs precise chemical gradients in consecutive microcompartments to perform microbial adaptive laboratory evolution (ALE), a key tool to study evolution in fundamental and applied contexts is described. In the chip developed here, microbial cells can be exposed to a defined profile of stressors such as antibiotics. By modulating this profile, stress adaptation in the chip through resistance or persistence can be specifically controlled. Importantly, chip-based ALE leads to the discovery of previously unknown mutations in Escherichia coli that confer resistance to nalidixic acid. The microfluidic device presented here can enhance the occurrence of mutations employing defined micro-environmental conditions to generate data to better understand the parameters that influence the mechanisms of antibiotic resistance.
Collapse
Affiliation(s)
- Ahmed E Zoheir
- Institute for Biological Interfaces 1 (IBG-1), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen, 76344, Germany
- Department of Genetics and Cytology, National Research Centre (NRC), 33 El Buhouth St., Cairo, 12622, Egypt
| | - Georg P Späth
- Institute for Biological Interfaces 1 (IBG-1), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen, 76344, Germany
| | - Christof M Niemeyer
- Institute for Biological Interfaces 1 (IBG-1), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen, 76344, Germany
| | - Kersten S Rabe
- Institute for Biological Interfaces 1 (IBG-1), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen, 76344, Germany
| |
Collapse
|
12
|
Affiliation(s)
- Xingdong Yang
- Department of Chemical Engineering Sichuan University Chengdu P.R. China
| | - Wenqiang Xiao
- Department of Chemical Engineering Sichuan University Chengdu P.R. China
| | - Shuang Dai
- Department of Chemical Engineering Sichuan University Chengdu P.R. China
| | - Jiyan Qu
- Department of Chemical Engineering Sichuan University Chengdu P.R. China
| | - Jianhong Luo
- Department of Chemical Engineering Sichuan University Chengdu P.R. China
| |
Collapse
|
13
|
Pinck S, Ostormujof LM, Teychené S, Erable B. Microfluidic Microbial Bioelectrochemical Systems: An Integrated Investigation Platform for a More Fundamental Understanding of Electroactive Bacterial Biofilms. Microorganisms 2020; 8:E1841. [PMID: 33238493 PMCID: PMC7700166 DOI: 10.3390/microorganisms8111841] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 11/18/2020] [Accepted: 11/19/2020] [Indexed: 12/31/2022] Open
Abstract
It is the ambition of many researchers to finally be able to close in on the fundamental, coupled phenomena that occur during the formation and expression of electrocatalytic activity in electroactive biofilms. It is because of this desire to understand that bioelectrochemical systems (BESs) have been miniaturized into microBES by taking advantage of the worldwide development of microfluidics. Microfluidics tools applied to bioelectrochemistry permit even more fundamental studies of interactions and coupled phenomena occurring at the microscale, thanks, in particular, to the concomitant combination of electroanalysis, spectroscopic analytical techniques and real-time microscopy that is now possible. The analytical microsystem is therefore much better suited to the monitoring, not only of electroactive biofilm formation but also of the expression and disentangling of extracellular electron transfer (EET) catalytic mechanisms. This article reviews the details of the configurations of microfluidic BESs designed for selected objectives and their microfabrication techniques. Because the aim is to manipulate microvolumes and due to the high modularity of the experimental systems, the interfacial conditions between electrodes and electrolytes are perfectly controlled in terms of physicochemistry (pH, nutrients, chemical effectors, etc.) and hydrodynamics (shear, material transport, etc.). Most of the theoretical advances have been obtained thanks to work carried out using models of electroactive bacteria monocultures, mainly to simplify biological investigation systems. However, a huge virgin field of investigation still remains to be explored by taking advantage of the capacities of microfluidic BESs regarding the complexity and interactions of mixed electroactive biofilms.
Collapse
Affiliation(s)
| | | | | | - Benjamin Erable
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, 31432 Toulouse, France; (S.P.); (L.M.O.); (S.T.)
| |
Collapse
|
14
|
Abstract
Bacterial motility in response to chemicals, also called bacterial chemotaxis, is a critical ability to search for the optimal environment to ensure the survival of bacterial species. Recent advances in microbiology have allowed the engineering of bacterial chemotactic properties. Conventional methods for characterizing bacterial motility are not able to fully monitor chemotactic behavior. Developments in microfluidic technology have enabled the designing of new experimental protocols in which spatiotemporal control of the cellular microenvironment can be achieved, and in which bacterial motility can be precisely and quantitatively measured and compared. This review provides an overview of recent developments of and new insights into microfluidic systems for chemotaxis assay.
Collapse
Affiliation(s)
- Heon-Ho Jeong
- Department of Chemical and Biomolecular Engineering, Chonnam National University, Yeosu, Jeonnam, Republic of Korea
| |
Collapse
|
15
|
Abstract
The integration of microfluidics with biomedical research is confronted with considerable limitations due to its body materials. With high content of water, hydrogels own superior biocompatibility and degradability. Can hydrogels become another material choice for the construction of microfluidic chips, particularly biofluidics? The present review aims to systematically establish the concept of hydrogel-based microfluidic chips (HMCs) and address three main concerns: i) why choosing hydrogels? ii) how to fabricate HMCs?, and iii) in which fields to apply HMCs? It is envisioned that hydrogels may be used increasingly as substitute for traditional materials and gradually act as the body material for microfluidic chips. The modifications of conventional process are highlighted to overcome issues arising from the incompatibility between the construction methods and hydrogel materials. Specifically targeting at the "soft and wet" hydrogels, an efficient flowchart of "i) high resolution template printing; ii) damage-free demolding; iii) twice-crosslinking bonding" is proposed. Accordingly, a broader microfluidic chip concept is proposed in terms of form and function. Potential biomedical applications of HMCs are discussed. This review also highlights the challenges arising from the material replacement, as well as the future directions of the proposed concept. Finally, the authors' viewpoints and perspectives for this emerging field are discussed.
Collapse
Affiliation(s)
- Jing Nie
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
- Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Jianzhong Fu
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
- Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yong He
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
- Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
- Key Laboratory of Materials Processing and Mold, Zhengzhou University, Zhengzhou, 450002, China
| |
Collapse
|
16
|
Lin KC, Sun Y, Torga G, Sherpa P, Zhao Y, Qu J, Amend SR, Pienta KJ, Sturm JC, Austin RH. An in vitro tumor swamp model of heterogeneous cellular and chemotherapeutic landscapes. Lab Chip 2020; 20:2453-2464. [PMID: 32555901 DOI: 10.1039/d0lc00131g] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The heterogenous, highly metabolic stressed, poorly irrigated, solid tumor microenvironment - the tumor swamp - is widely recognized to play an important role in cancer progression as well as the development of therapeutic resistance. It is thus important to create realistic in vitro models within the therapeutic pipeline that can recapitulate the fundamental stress features of the tumor swamp. Here we describe a microfluidic system which generates a chemical gradient within connected microenvironments achieved through a static diffusion mechanism rather than active pumping. We show that the gradient can be stably maintained for over a week. Due to the accessibility and simplicity of the experimental platform, the system allows for not only well-controlled continuous studies of the interactions among various cell types at single-cell resolution, but also parallel experimentation for time-resolved downstream cellular assays on the time scale of weeks. This approach enables simple, compact implementation and is compatible with existing 6-well imaging technology for simultaneous experiments. As a proof-of-concept, we report the co-culture of a human bone marrow stromal cell line and a bone-metastatic prostate cancer cell line using the presented device, revealing on the same chip a transition in cancer cell survival as a function of drug concentration on the population level while exhibiting an enrichment of poly-aneuploid cancer cells (PACCs) as an evolutionary consequence of high stress. The device allows for the quantitative study of cancer cell dynamics on a stress landscape by real-time monitoring of various cell types with considerable experimental throughput.
Collapse
Affiliation(s)
- Ke-Chih Lin
- Department of Physics, Princeton University, Princeton, NJ 08544, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
The microfluidics field is at a critical crossroads. The vast majority of microfluidic devices are presently manufactured using micromolding processes that work very well for a reduced set of biocompatible materials, but the time, cost, and design constraints of micromolding hinder the commercialization of many devices. As a result, the dissemination of microfluidic technology-and its impact on society-is in jeopardy. Digital manufacturing (DM) refers to a family of computer-centered processes that integrate digital three-dimensional (3D) designs, automated (additive or subtractive) fabrication, and device testing in order to increase fabrication efficiency. Importantly, DM enables the inexpensive realization of 3D designs that are impossible or very difficult to mold. The adoption of DM by microfluidic engineers has been slow, likely due to concerns over the resolution of the printers and the biocompatibility of the resins. In this article, we review and discuss the various printer types, resolution, biocompatibility issues, DM microfluidic designs, and the bright future ahead for this promising, fertile field.
Collapse
Affiliation(s)
- Arman Naderi
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| | - Nirveek Bhattacharjee
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| | - Albert Folch
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| |
Collapse
|
18
|
Yang CY, Erickstad M, Tadrist L, Ronan E, Gutierrez E, Wong-Ng J, Groisman A. Aggregation Temperature of Escherichia coli Depends on Steepness of the Thermal Gradient. Biophys J 2020; 118:2816-2828. [PMID: 32348719 DOI: 10.1016/j.bpj.2020.02.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 01/14/2020] [Accepted: 02/03/2020] [Indexed: 11/30/2022] Open
Abstract
Bacterial chemotaxis, the directed migration of bacteria in a gradient of chemoattractant, is one of the most well-studied and well-understood processes in cell biology. On the other hand, bacterial thermotaxis, the directed migration of bacteria in a gradient of temperature, is understood relatively poorly, with somewhat conflicting reports by different groups. One of the reasons for that is the relative technical difficulty of the generation of well-defined gradients of temperature that are sufficiently steep to elicit readily detectable thermotaxis. Here, we used a specially designed microfluidic device to study thermotaxis of Escherichia coli in a broad range of thermal gradients with a high rate of data collection. We found that in shallow temperature gradients with narrow temperature ranges, E. coli tended to aggregate near a sidewall of the gradient channel at either the lowest or the highest temperature. On the other hand, in sufficiently steep gradients with wide temperature ranges, E. coli aggregated at intermediate temperatures, with maximal cell concentrations found away from the sidewalls. We observed this intermediate temperature aggregation in a motility buffer that did not contain any major chemoattractants of E. coli, in contradiction to some previous reports, which suggested that this type of aggregation required the presence of at least one major chemoattractant in the medium. Even more surprisingly, the aggregation temperature strongly depended on the gradient steepness, decreasing by ∼10° as the steepness was increased from 27 to 53°C/mm. Our experiments also highlight the fact that assessments of thermal gradients by changes in fluorescence of temperature-sensitive fluorescent dyes need to account for thermophoresis of the dyes.
Collapse
Affiliation(s)
- Chih-Yu Yang
- Department of Physics, University of California, San Diego, La Jolla, California
| | - Michael Erickstad
- Department of Physics, University of California, San Diego, La Jolla, California
| | - Loïc Tadrist
- Department of Physics, University of California, San Diego, La Jolla, California
| | - Edward Ronan
- Department of Physics, University of California, San Diego, La Jolla, California
| | - Edgar Gutierrez
- Department of Physics, University of California, San Diego, La Jolla, California
| | - Jérôme Wong-Ng
- Department of Physics, University of California, San Diego, La Jolla, California.
| | - Alex Groisman
- Department of Physics, University of California, San Diego, La Jolla, California.
| |
Collapse
|
19
|
Garcia-Seyda N, Aoun L, Tishkova V, Seveau V, Biarnes-Pelicot M, Bajénoff M, Valignat MP, Theodoly O. Microfluidic device to study flow-free chemotaxis of swimming cells. Lab Chip 2020; 20:1639-1647. [PMID: 32249280 DOI: 10.1039/d0lc00045k] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Microfluidic devices have been used in the last two decades to study in vitro cell chemotaxis, but few existing devices generate gradients in flow-free conditions. Flow can bias cell directionality of adherent cells and precludes the study of swimming cells like naïve T lymphocytes, which only migrate in a non-adherent fashion. We developed two devices that create stable, flow-free, diffusion-based gradients and are adapted for adherent and swimming cells. The flow-free environment is achieved by using agarose gel barriers between a central channel with cells and side channels with chemoattractants. These barriers insulate cells from injection/rinsing cycles of chemoattractants, they dampen residual drift across the device, and they allow co-culture of cells without physical interaction, to study contactless paracrine communication. Our devices were used here to investigate neutrophil and naïve T lymphocyte chemotaxis.
Collapse
Affiliation(s)
- Nicolas Garcia-Seyda
- Aix Marseille Univ, Inserm, CNRS, Turing Center for Living Systems, LAI, Marseille, France.
| | - Laurene Aoun
- Aix Marseille Univ, Inserm, CNRS, Turing Center for Living Systems, LAI, Marseille, France.
| | | | - Valentine Seveau
- Aix Marseille Univ, Inserm, CNRS, Turing Center for Living Systems, LAI, Marseille, France.
| | | | - Marc Bajénoff
- Aix Marseille Univ, Inserm, CNRS, CIML, Marseille, France
| | - Marie-Pierre Valignat
- Aix Marseille Univ, Inserm, CNRS, Turing Center for Living Systems, LAI, Marseille, France.
| | - Olivier Theodoly
- Aix Marseille Univ, Inserm, CNRS, Turing Center for Living Systems, LAI, Marseille, France.
| |
Collapse
|
20
|
Esplandiu MJ, Reguera D, Fraxedas J. Electrophoretic origin of long-range repulsion of colloids near water/Nafion interfaces. Soft Matter 2020; 16:3717-3726. [PMID: 32232286 DOI: 10.1039/d0sm00170h] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
One of the most striking properties of Nafion is the formation of a long-range solute exclusion zone (EZ) in contact with water. The mechanism of formation of this EZ has been the subject of a controversial and long-standing debate. Previous studies by Schurr et al. and Florea et al. root the explanation of this phenomenon in the ion-exchange properties of Nafion, which generates ion diffusion and ion gradients that drive the repulsion of solutes by diffusiophoresis. Here we have evaluated separately the electrophoretic and chemiphoretic contributions to multi-ionic diffusiophoresis using differently charged colloidal tracers as solutes to identify better their contribution in the EZ formation. Our experimental results, which are also supported by numerical simulations, show that the electric field, built up due to the unequal diffusion coefficients of the exchanged ions, is the dominant parameter behind such interfacial phenomenon in the presence of alkali metal chlorides. The EZ formation depends on the interplay of the electric field with the zeta potential of the solute and can be additionally modulated by changing ion diffusion coefficients or adding salts. As a consequence, we show that not all solutes can be expelled from the Nafion interface and hence the EZ is not always formed. This study thus provides a more detailed description of the origin and dynamics of this phenomenon and opens the door to the rational use of this active interface for many potential applications.
Collapse
Affiliation(s)
- Maria J Esplandiu
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| | - David Reguera
- Departament de Física de la Matèria Condensada, Universitat de Barcelona, C/Martí i Franquès 1, 08028 Barcelona, Spain and Universitat de Barcelona, Institute of Complex Systems (UBICS), C/Martí i Franquès 1, 08028 Barcelona, Spain
| | - Jordi Fraxedas
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| |
Collapse
|
21
|
Abstract
Current male fertility diagnosis tests focus on assessing the quality of semen samples by studying the concentration, total volume, and motility of spermatozoa. However, other characteristics such as the chemotactic ability of a spermatozoon might influence the chance of fertilization. Here we describe a simple, easy to fabricate and handle, flow-free microfluidic chip to test the chemotactic response of spermatozoa made out of a hybrid hydrogel (8% gelatin/1% agarose). A chemotaxis experiment with 1 μM progesterone was performed that significantly demonstrated that boar spermatozoa are attracted by a progesterone gradient.
Collapse
Affiliation(s)
- Johanna T W Berendsen
- BIOS-Lab on a Chip Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine , University of Twente , 7500 AE Enschede , The Netherlands
| | - Stella A Kruit
- BIOS-Lab on a Chip Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine , University of Twente , 7500 AE Enschede , The Netherlands
| | - Nihan Atak
- BIOS-Lab on a Chip Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine , University of Twente , 7500 AE Enschede , The Netherlands
| | - Ellen Willink
- BIOS-Lab on a Chip Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine , University of Twente , 7500 AE Enschede , The Netherlands
| | - Loes I Segerink
- BIOS-Lab on a Chip Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine , University of Twente , 7500 AE Enschede , The Netherlands
| |
Collapse
|
22
|
Ebadi M, Moshksayan K, Kashaninejad N, Saidi MS, Nguyen N. A tool for designing tree-like concentration gradient generators for lab-on-a-chip applications. Chem Eng Sci 2020; 212:115339. [DOI: 10.1016/j.ces.2019.115339] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
23
|
Wioland H, Suzuki E, Cao L, Romet-Lemonne G, Jegou A. The advantages of microfluidics to study actin biochemistry and biomechanics. J Muscle Res Cell Motil 2019; 41:175-188. [PMID: 31749040 PMCID: PMC7109186 DOI: 10.1007/s10974-019-09564-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 10/26/2019] [Indexed: 11/24/2022]
Abstract
The regulated assembly of actin filaments is essential in nearly all cell types. Studying actin assembly dynamics can pose many technical challenges. A number of these challenges can be overcome by using microfluidics to observe and manipulate single actin filaments under an optical microscope. In particular, microfluidics can be tremendously useful for applying different mechanical stresses to actin filaments and determining how the physical context of the filaments affects their regulation by biochemical factors. In this review, we summarize the main features of microfluidics for the study of actin assembly dynamics, and we highlight some recent developments that have emerged from the combination of microfluidics and other techniques. We use two case studies to illustrate our points: the rapid assembly of actin filaments by formins and the disassembly of filaments by actin depolymerizing factor (ADF)/cofilin. Both of these protein families play important roles in cells. They regulate actin assembly through complex molecular mechanisms that are sensitive to the filaments’ mechanical context, with multiple activities that need to be quantified separately. Microfluidics-based experiments have been extremely useful for gaining insight into the regulatory actions of these two protein families.
Collapse
Affiliation(s)
- Hugo Wioland
- Institut Jacques Monod, CNRS, Université de Paris, 75013, Paris, France
| | - Emiko Suzuki
- Institut Jacques Monod, CNRS, Université de Paris, 75013, Paris, France
| | - Luyan Cao
- Institut Jacques Monod, CNRS, Université de Paris, 75013, Paris, France
| | | | - Antoine Jegou
- Institut Jacques Monod, CNRS, Université de Paris, 75013, Paris, France.
| |
Collapse
|
24
|
Sun J, Warden AR, Ding X. Recent advances in microfluidics for drug screening. Biomicrofluidics 2019; 13:061503. [PMID: 31768197 PMCID: PMC6870548 DOI: 10.1063/1.5121200] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 11/07/2019] [Indexed: 05/03/2023]
Abstract
With ever increasing drug resistance and emergence of new diseases, demand for new drug development is at an unprecedented urgency. This fact has led to extensive recent efforts to develop new drugs and novel techniques for efficient drug screening. However, new drug development is commonly hindered by cost and time span. Thus, developing more accessible, cost-effective methods for drug screening is necessary. Compared with conventional drug screening methods, a microfluidic-based system has superior advantages in sample consumption, reaction time, and cost of the operation. In this paper, the advantages of microfluidic technology in drug screening as well as the critical factors for device design are described. The strategies and applications of microfluidics for drug screening are reviewed. Moreover, current limitations and future prospects for a drug screening microdevice are also discussed.
Collapse
|
25
|
Gaines A, Ludovice M, Xu J, Zanghi M, Meinersmann RJ, Berrang M, Daley W, Britton D. The dialogue between protozoa and bacteria in a microfluidic device. PLoS One 2019; 14:e0222484. [PMID: 31596855 PMCID: PMC6784911 DOI: 10.1371/journal.pone.0222484] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Accepted: 08/30/2019] [Indexed: 01/28/2023] Open
Abstract
In nature, protozoa play a major role in controlling bacterial populations. This paper proposes a microfluidic device for the study of protozoa behaviors change due to their chemotactic response in the presence of bacterial cells. A three-channel microfluidic device was designed using a nitrocellulose membrane into which channels were cut using a laser cutter. The membrane was sandwiched between two glass slides; a Euglena suspension was then allowed to flow through the central channel. The two side channels were filled with either, 0.1% peptone as a negative control, or a Listeria suspension respectively. The membrane design prevented direct interaction but allowed Euglena cells to detect Listeria cells as secretions diffused through the nitrocellulose membrane. A significant number of Euglena cells migrated toward the chambers near the bacterial cells, indicating a positive chemotactic response of Euglena toward chemical cues released from Listeria cells. Filtrates collected from Listeria suspension with a series of molecular weight cutoffs (3k, 10k and 100k) were examined in Euglena chemotaxis tests. Euglena cells were attracted to all filtrates collected from the membrane filtration with different molecular weight cutoffs, suggesting small molecules from Listeria might be the chemical cues to attract protozoa. Headspace volatile organic compounds (VOC) released from Listeria were collected, spiked to 0.1% peptone and tested as the chemotactic effectors. It was discovered that the Euglena cells responded quickly to Listeria VOCs including decanal, 3,5- dimethylbenzaldehyde, ethyl acetate, indicating bacterial VOCs were used by Euglena to track the location of bacteria.
Collapse
Affiliation(s)
- Anna Gaines
- Aerospace, Transportation and Advanced Systems Laboratory, Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Miranda Ludovice
- Aerospace, Transportation and Advanced Systems Laboratory, Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Jie Xu
- Aerospace, Transportation and Advanced Systems Laboratory, Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Marc Zanghi
- Aerospace, Transportation and Advanced Systems Laboratory, Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Richard J. Meinersmann
- Richard B. Russell Research Center, Agricultural Research Service, United States Department of Agriculture, Athens, Georgia, United States of America
| | - Mark Berrang
- Richard B. Russell Research Center, Agricultural Research Service, United States Department of Agriculture, Athens, Georgia, United States of America
| | - Wayne Daley
- Aerospace, Transportation and Advanced Systems Laboratory, Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| | - Doug Britton
- Aerospace, Transportation and Advanced Systems Laboratory, Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, Georgia, United States of America
| |
Collapse
|
26
|
Lee B, Jeong H, Kang K, Lee C, Lee S. Improvement of a diffusion-based microfluidic chemotaxis assay through stable formation of a chemical gradient. Chem Eng Sci 2019; 202:130-7. [DOI: 10.1016/j.ces.2019.03.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
27
|
Abstract
Biological gradients profoundly influence many cellular activities, such as adhesion, migration, and differentiation, which are the key to biological processes, such as inflammation, remodeling, and tissue regeneration. Thus, engineered structures containing bioinspired gradients can not only support a better understanding of these phenomena, but also guide and improve the current limits of regenerative medicine. In this review, we outline the challenges behind the engineering of devices containing chemical-physical and biomolecular gradients, classifying them according to gradient-making methods and the finalities of the systems. Different manufacturing processes can generate gradients in either in-vitro systems or scaffolds, which are suitable tools for the study of cellular behavior and for regenerative medicine; within these, rapid prototyping techniques may have a huge impact on the controlled production of gradients. The parallel need to develop characterization techniques is addressed, underlining advantages and weaknesses in the analysis of both chemical and physical gradients.
Collapse
Affiliation(s)
- L Sardelli
- 1 Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - D P Pacheco
- 1 Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - L Zorzetto
- 2 Department of Aerospace and Mechanical Engineering, University of Liège, Liège, Belgium
| | - C Rinoldi
- 3 Faculty of Materials Science and Engineering, Warsaw University of Technology, Poland
| | - W Święszkowski
- 3 Faculty of Materials Science and Engineering, Warsaw University of Technology, Poland
| | - P Petrini
- 1 Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| |
Collapse
|
28
|
Virgile C, Hauk P, Wu HC, Bentley WE. Plasmid-encoded protein attenuates Escherichia coli swimming velocity and cell growth, not reprogrammed regulatory functions. Biotechnol Prog 2019; 35:e2778. [PMID: 30666816 PMCID: PMC10711804 DOI: 10.1002/btpr.2778] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 12/28/2018] [Accepted: 01/10/2019] [Indexed: 12/17/2023]
Abstract
In addition to engineering new pathways for synthesis, synthetic biologists rewire cells to carry out "programmable" functions, an example being the creation of wound-healing probiotics. Engineering regulatory circuits and synthetic machinery, however, can be deleterious to cell function, particularly if the "metabolic burden" is significant. Here, a synthetic regulatory circuit previously constructed to direct Escherichia coli to swim toward hydrogen peroxide, a signal of wound generation, was shown to work even with coexpression of antibiotic resistance genes and genes associated with lactose utilization. We found, however, that cotransformation with a second vector constitutively expressing GFP (as a marker) and additionally conferring resistance to kanamycin and tetracycline resulted in slower velocity (Δ~6 μm/s) and dramatically reduced growth rate (Δ > 50%). The additional vector did not, however, alter the run-and-tumble ratio or directional characteristics of H2 O2 -dependent motility. The main impact of this additional burden was limited to slowing cell velocity and growth, suggesting that reprogrammed cell motility by minimally altering native regulatory circuits can be maintained even when extraneous burden is placed on the host cell. © 2019 American Institute of Chemical Engineers Biotechnol. Prog., 35: e2778, 2019.
Collapse
Affiliation(s)
- Chelsea Virgile
- Institute for Bioscience and Biotechnology Research, College Park, MD 20742
- Fischell Department of Bioengineering, Room 3122, Jeong H. Kim Engineering Building (Bldg. #225), University of Maryland, College Park, MD 20742
| | - Pricila Hauk
- Institute for Bioscience and Biotechnology Research, College Park, MD 20742
- Fischell Department of Bioengineering, Room 3122, Jeong H. Kim Engineering Building (Bldg. #225), University of Maryland, College Park, MD 20742
| | - Hsuan-Chen Wu
- Department of Biochemical Science and Technology, National Taiwan University, Taipei City, Taiwan
| | - William E. Bentley
- Institute for Bioscience and Biotechnology Research, College Park, MD 20742
- Fischell Department of Bioengineering, Room 3122, Jeong H. Kim Engineering Building (Bldg. #225), University of Maryland, College Park, MD 20742
| |
Collapse
|
29
|
Mestres G, Perez RA, D’Elía NL, Barbe L. Advantages of microfluidic systems for studying cell-biomaterial interactions—focus on bone regeneration applications. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/ab1033] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
30
|
Davidov T, Granik N, Zahran S, Leonard H, Adir I, Elul O, Fried T, Gil A, Mayo B, Ohayon S, Sarig S, Shasha N, Tsedef S, Weiner S, Brunwasser-Meirom M, Ereskovsky A, Katz N, Kaufmann B, Haimov Y, Segal E, Amit R. Designing Bacterial Chemotactic Receptors Guided by Photonic Femtoliter Well Arrays for Quantifiable, Label-Free Measurement of Bacterial Chemotaxis. ACS Biomater Sci Eng 2019; 5:603-612. [PMID: 33405824 DOI: 10.1021/acsbiomaterials.8b01429] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Whole cell bioreporters, such as bacterial cells, can be used for environmental and clinical sensing of specific analytes. However, the current methods implemented to observe such bioreporters in the form of chemotactic responses heavily rely on microscope analysis, fluorescent labels, and hard-to-scale microfluidic devices. Herein, we demonstrate that chemotaxis can be detected within minutes using intrinsic optical measurements of silicon femtoliter well arrays (FMAs). This is done via phase-shift reflectometric interference spectroscopic measurements (PRISM) of the wells, which act as silicon diffraction gratings, enabling label-free, real-time quantification of the number of trapped bacteria cells in the optical readout. By generating unsteady chemical gradients over the wells, we first demonstrate that chemotaxis toward attractants and away from repellents can be easily differentiated based on the signal response of PRISM. The lowest concentration of chemorepellent to elicit an observed bacterial response was 50 mM, whereas the lowest concentration of chemoattractant to elicit a response was 10 mM. Second, we employed PRISM, in combination with a computational approach, to rapidly scan for and identify a novel synthetic histamine chemoreceptor strain. Consequently, we show that by using a combined computational design approach, together with a quantitative, real-time, and label-free detection method, it is possible to manufacture and characterize novel synthetic chemoreceptors in Escherichia coli (E. coli).
Collapse
|
31
|
Lim GS, Hor JH, Ho NR, Wong CY, Ng SY, Soh BS, Shao H. Microhexagon gradient array directs spatial diversification of spinal motor neurons. Theranostics 2019; 9:311-323. [PMID: 30809276 PMCID: PMC6376181 DOI: 10.7150/thno.29755] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Accepted: 11/20/2018] [Indexed: 11/30/2022] Open
Abstract
Motor neuron diversification and regionalization are important hallmarks of spinal cord development and rely on fine spatiotemporal release of molecular cues. Here, we present a dedicated platform to engineer complex molecular profiles for directed neuronal differentiation. Methods: The technology, termed microhexagon interlace for generation of versatile and fine gradients (microHIVE), leverages on an interlocking honeycomb lattice of microstructures to dynamically pattern molecular profiles at a high spatial resolution. By packing the microhexagons as a divergent, mirrored array, the platform not only enables maximal mixing efficiency but also maintains a small device footprint. Results: Employing the microHIVE platform, we developed optimized profiles of growth factors to induce rostral-caudal patterning of spinal motor neurons, and directed stem cell differentiation in situ into a spatial continuum of different motor neuron subtypes. Conclusions: The differentiated cells showed progressive RNA and protein signatures, consistent with that of representative brachial, thoracic and lumbar regions of the human spinal cord. The microHIVE platform can thus be utilized to develop advanced biomimetic systems for the study of diseases in vitro.
Collapse
Affiliation(s)
- Geok Soon Lim
- Biomedical Institute for Global Health Research and Technology, National University of Singapore, 117599, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
| | - Jin Hui Hor
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
- Department of Biological Sciences, Faculty of Science, National University of Singapore, 117543, Singapore
| | - Nicholas R.Y. Ho
- Biomedical Institute for Global Health Research and Technology, National University of Singapore, 117599, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
| | - Chi Yan Wong
- Biomedical Institute for Global Health Research and Technology, National University of Singapore, 117599, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
| | - Shi Yan Ng
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
- Department of Physiology, Yong Loo Lin School of Medicine, National University of Singapore, 117456, Singapore
- National Neuroscience Institute, 308433, Singapore
- Key Laboratory for Major Obstetric Diseases of Guangdong Province, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China
| | - Boon Seng Soh
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
- Department of Biological Sciences, Faculty of Science, National University of Singapore, 117543, Singapore
- Key Laboratory for Major Obstetric Diseases of Guangdong Province, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China
| | - Huilin Shao
- Biomedical Institute for Global Health Research and Technology, National University of Singapore, 117599, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research, 138673, Singapore
- National Neuroscience Institute, 308433, Singapore
- Department of Biomedical Engineering, Faculty of Engineering, National University of Singapore, 117583, Singapore
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, 119228, Singapore
| |
Collapse
|
32
|
Abstract
A micro-level technique so-called “microfluidic technology or simply microfluidic” has gained a special place as a powerful tool in bioengineering and biomedical engineering research due to its core advantages in modern science and engineering. Microfluidic technology has played a substantial role in numerous applications with special reference to bioscience, biomedical and biotechnological research. It has facilitated noteworthy development in various sectors of bio-research and upsurges the efficacy of research at the molecular level, in recent years. Microfluidic technology can manipulate sample volumes with precise control outside cellular microenvironment, at micro-level. Thus, enable the reduction of discrepancies between in vivo and in vitro environments and reduce the overall reaction time and cost. In this review, we discuss various integrations of microfluidic technologies into biotechnology and its paradigmatic significance in bio-research, supporting mechanical and chemical in vitro cellular microenvironment. Furthermore, specific innovations related to the application of microfluidics to advance microbial life, solitary and co-cultures along with a multiple-type cell culturing, cellular communications, cellular interactions, and population dynamics are also discussed.
Collapse
|
33
|
Sule N, Penarete-Acosta D, Englert DL, Jayaraman A. A Static Microfluidic Device for Investigating the Chemotaxis Response to Stable, Non-linear Gradients. Methods Mol Biol 2018; 1729:47-59. [PMID: 29429081 DOI: 10.1007/978-1-4939-7577-8_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Microfluidic technology allows fast and precise measurement of chemotaxis responses to both attractant and repellent signals. One of the major drawbacks of current microfluidic chemotaxis assays is the presence of bacterial cells within the concentration gradient flow field, which has the potential for flow effects masking the chemotaxis response. This chapter describes a new microfluidic device for producing stable concentration gradients and measuring the response of cells to the gradient without exposing them to any flow. Unlike other methods described in the literature, this method is capable of producing gradients of any shape, almost instantaneously, allowing the measurement of time-dependent response of cells to a variety of signals.
Collapse
|
34
|
Harris AR, Yuan JX, Munson JM. Assessing multiparametric drug response in tissue engineered tumor microenvironment models. Methods 2018; 134-135:20-31. [PMID: 29258924 DOI: 10.1016/j.ymeth.2017.12.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Revised: 11/18/2017] [Accepted: 12/13/2017] [Indexed: 12/17/2022] Open
Abstract
The tumor microenvironment is important in promoting treatment resistance of tumor cells via multiple mechanisms. However, studying this interaction often proves difficult. In vivo animal models are costly, time-consuming, and often fail to adequately predict human response to treatment. Conversely, testing drug response on human tumor cells in vitro in 2D cell culture excludes the important contribution of stromal cells and biophysical forces seen in the in vivo tumor microenvironment. Here, we present tissue-engineered models of both human brain and breast tumor microenvironments incorporating key stromal cell populations for assessing multiple mechanisms of therapeutic response using flow cytometry. We show our physiologically-relevant systems used to interrogate a variety of parameters associated with chemotherapeutic efficacy, including cell death, proliferation, drug uptake, and invasion of cancer and stromal cell populations. The use of flow cytometry allows for single cell, quantitative, and fast assessments of multiple outcomes affecting anti-tumor therapy failure. Our system can be modified to add and remove cellular components with ease, thereby enabling the study of individual cellular contributions in the tumor microenvironment. Together, our models and analysis methods illustrate the importance of developing fast, cost-effective, and reproducible methods to model complex human systems in a physiologically-relevant manner that may prove useful for drug screening efforts in the future.
Collapse
|
35
|
Zhuang J, Park B, Sitti M. Propulsion and Chemotaxis in Bacteria-Driven Microswimmers. Adv Sci (Weinh) 2017; 4:1700109. [PMID: 28932674 PMCID: PMC5604384 DOI: 10.1002/advs.201700109] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 04/24/2017] [Indexed: 05/21/2023]
Abstract
Despite the large body of experimental work recently on biohybrid microsystems, few studies have focused on theoretical modeling of such systems, which is essential to understand their underlying functioning mechanisms and hence design them optimally for a given application task. Therefore, this study focuses on developing a mathematical model to describe the 3D motion and chemotaxis of a type of widely studied biohybrid microswimmer, where spherical microbeads are driven by multiple attached bacteria. The model is developed based on the biophysical observations of the experimental system and is validated by comparing the model simulation with experimental 3D swimming trajectories and other motility characteristics, including mean squared displacement, speed, diffusivity, and turn angle. The chemotaxis modeling results of the microswimmers also agree well with the experiments, where a collective chemotactic behavior among multiple bacteria is observed. The simulation result implies that such collective chemotaxis behavior is due to a synchronized signaling pathway across the bacteria attached to the same microswimmer. Furthermore, the dependencies of the motility and chemotaxis of the microswimmers on certain system parameters, such as the chemoattractant concentration gradient, swimmer body size, and number of attached bacteria, toward an optimized design of such biohybrid system are studied. The optimized microswimmers would be used in targeted cargo, e.g., drug, imaging agent, gene, and RNA, transport and delivery inside the stagnant or low-velocity fluids of the human body as one of their potential biomedical applications.
Collapse
Affiliation(s)
- Jiang Zhuang
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
- Department of Mechanical EngineeringCarnegie Mellon UniversityPittsburghPA15213USA
| | - Byung‐Wook Park
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
| | - Metin Sitti
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
- Department of Mechanical EngineeringCarnegie Mellon UniversityPittsburghPA15213USA
| |
Collapse
|
36
|
Kim M, Lim JW, Lee SK, Kim T. Nanoscale Hydrodynamic Film for Diffusive Mass Transport Control in Compartmentalized Microfluidic Chambers. Anal Chem 2017; 89:10286-10295. [DOI: 10.1021/acs.analchem.7b01966] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Minseok Kim
- Department
of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
| | - Ji Won Lim
- Department
of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
| | - Sung Kuk Lee
- Department
of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
- Department
of Chemical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
| | - Taesung Kim
- Department
of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
- Department
of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
| |
Collapse
|
37
|
Shang W, Tsao CY, Luo X, Teodoro M, McKay R, Quan DN, Wu HC, Payne GF, Bentley WE. A simple and reusable bilayer membrane-based microfluidic device for the study of gradient-mediated bacterial behaviors. Biomicrofluidics 2017; 11:044114. [PMID: 28868107 PMCID: PMC5566557 DOI: 10.1063/1.4993438] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 08/10/2017] [Indexed: 05/11/2023]
Abstract
We have developed a user-friendly microfluidic device for the study of gradient-mediated bacterial behaviors, including chemotaxis. This device rapidly establishes linear concentration gradients by exploiting solute diffusion through porous membranes in the absence of convective flows. As such, the gradients are created rapidly and can be sustained for long time periods (e.g., hours), sufficient to evaluate cell phenotype. The device exploits a unique simple bilayer configuration that enables rapid setup and quick reproducible introduction of cells. Its reusability represents an additional advantage in that it need not be limited to settings with microfluidics expertise. We have successfully demonstrated the applicability of this tool in studying the chemotactic response of Escherichia coli to glucose. When coupled with our recent Python program, quantified metrics such as speed, ratio of tumble to run, and effective diffusivity can be obtained from slow frame rate videos. Moreover, we introduce a chemotaxis partition coefficient that conveniently scores swimming behavior on the single-cell level.
Collapse
Affiliation(s)
| | | | - Xiaolong Luo
- Department of Mechanical Engineering, The Catholic University of America, Washington, 20064, USA
| | | | | | | | - Hsuan-Chen Wu
- Department of Biochemical Science and Technology, National Taiwan University, Taipei 10617, Taiwan
| | | | | |
Collapse
|
38
|
Morse M, Colin R, Wilson LG, Tang JX. The Aerotactic Response of Caulobacter crescentus. Biophys J 2016; 110:2076-84. [PMID: 27166815 DOI: 10.1016/j.bpj.2016.03.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 02/11/2016] [Accepted: 03/21/2016] [Indexed: 11/24/2022] Open
Abstract
Many motile microorganisms are able to detect chemical gradients in their surroundings to bias their motion toward more favorable conditions. In this study, we observe the swimming patterns of Caulobacter crescentus, a uniflagellated bacterium, in a linear oxygen gradient produced by a three-channel microfluidic device. Using low-magnification dark-field microscopy, individual cells are tracked over a large field of view and their positions within the oxygen gradient are recorded over time. Motor switching events are identified so that swimming trajectories are deconstructed into a series of forward and backward swimming runs. Using these data, we show that C. crescentus displays aerotactic behavior by extending the average duration of forward swimming runs while moving up an oxygen gradient, resulting in directed motility toward oxygen sources. Additionally, the motor switching response is sensitive both to the steepness of the gradient experienced and to background oxygen levels, exhibiting a logarithmic response.
Collapse
|
39
|
Abstract
Microfluidics is considered an important technology that is suitable for numerous biomedical applications, including cancer diagnosis, metastasis, drug delivery, and tissue engineering. Although microfluidics is still considered to be a new approach in urological research, several pioneering studies have been reported in recent years. In this paper, we reviewed urological research works using microfluidic devices. Microfluidic devices were used for the detection of prostate and bladder cancer and the characterization of cancer microenvironments. The potential applications of microfluidics in urinary analysis and sperm sorting were demonstrated. The use of microfluidic devices in urology research can provide high-throughput, high-precision, and low-cost analyzing platforms.
Collapse
|
40
|
Möller FM, Kriegel F, Kieß M, Sojo V, Braun D. Steep pH Gradients and Directed Colloid Transport in a Microfluidic Alkaline Hydrothermal Pore. Angew Chem Int Ed Engl 2017; 56:2340-2344. [PMID: 28117546 DOI: 10.1002/anie.201610781] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Revised: 01/09/2017] [Indexed: 11/08/2022]
Abstract
All life on earth depends on the generation and exploitation of ionic and pH gradients across membranes. One theory for the origin of life proposes that geological pH gradients were the prebiotic ancestors of these cellular disequilibria. With an alkaline interior and acidic exterior, alkaline vents match the topology of modern cells, but it remains unknown whether the steep pH gradients persist at the microscopic scale. Herein, we demonstrate the existence of 6 pH-unit gradients across micrometer scales in a microfluidic vent replicate. Precipitation of metal sulfides at the interface strengthens the gradients, but even in the absence of precipitates laminar flow sustains the disequilibria. The gradients drive directed transport at the fluid interface, leading to colloid accumulation or depletion. Our results confirm that alkaline vents can provide an exploitable pH gradient, supporting their potential role at the emergence of chemiosmosis and the origin of life.
Collapse
Affiliation(s)
- Friederike M Möller
- Systems Biophysics, Physics Department, Nanosystems Initiative Munich and Center for NanoScience, Ludwig-Maximilians-Universität München, Amalienstraße 54, 80799, München, Germany
| | - Franziska Kriegel
- Systems Biophysics, Physics Department, Nanosystems Initiative Munich and Center for NanoScience, Ludwig-Maximilians-Universität München, Amalienstraße 54, 80799, München, Germany
| | - Michael Kieß
- Systems Biophysics, Physics Department, Nanosystems Initiative Munich and Center for NanoScience, Ludwig-Maximilians-Universität München, Amalienstraße 54, 80799, München, Germany
| | - Victor Sojo
- Systems Biophysics, Physics Department, Nanosystems Initiative Munich and Center for NanoScience, Ludwig-Maximilians-Universität München, Amalienstraße 54, 80799, München, Germany
| | - Dieter Braun
- Systems Biophysics, Physics Department, Nanosystems Initiative Munich and Center for NanoScience, Ludwig-Maximilians-Universität München, Amalienstraße 54, 80799, München, Germany
| |
Collapse
|
41
|
Möller FM, Kriegel F, Kieß M, Sojo V, Braun D. Steep pH Gradients and Directed Colloid Transport in a Microfluidic Alkaline Hydrothermal Pore. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201610781] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Friederike M. Möller
- Systems Biophysics; Physics Department; Nanosystems Initiative Munich and Center for NanoScience; Ludwig-Maximilians-Universität München; Amalienstraße 54 80799 München Germany
| | - Franziska Kriegel
- Systems Biophysics; Physics Department; Nanosystems Initiative Munich and Center for NanoScience; Ludwig-Maximilians-Universität München; Amalienstraße 54 80799 München Germany
| | - Michael Kieß
- Systems Biophysics; Physics Department; Nanosystems Initiative Munich and Center for NanoScience; Ludwig-Maximilians-Universität München; Amalienstraße 54 80799 München Germany
| | - Victor Sojo
- Systems Biophysics; Physics Department; Nanosystems Initiative Munich and Center for NanoScience; Ludwig-Maximilians-Universität München; Amalienstraße 54 80799 München Germany
| | - Dieter Braun
- Systems Biophysics; Physics Department; Nanosystems Initiative Munich and Center for NanoScience; Ludwig-Maximilians-Universität München; Amalienstraße 54 80799 München Germany
| |
Collapse
|
42
|
Pham P, Vo T, Luo X. Steering air bubbles with an add-on vacuum layer for biopolymer membrane biofabrication in PDMS microfluidics. Lab Chip 2017; 17:248-255. [PMID: 27942655 DOI: 10.1039/c6lc01362g] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Membrane functionality is crucial in microfluidics for realizing operations such as filtration, separation, concentration, signaling among cells and gradient generation. Currently, common methods often sandwich commercially available membranes in multi-layer devices, or use photopolymerization or temperature-induced gelation to fabricate membrane structures in one-layer devices. Biofabrication offers an alternative to forming membrane structures with biomimetic materials and mechanisms in mild conditions. We have recently developed a biofabrication strategy to form parallel biopolymer membranes in gas-permeable polydimethylsiloxane (PDMS) microfluidic devices, which used positive pressure to dissipate air bubbles through PDMS to initiate membrane formation but required careful pressure balancing between two flows. Here, we report a technical innovation by simply placing as needed an add-on PDMS vacuum layer on PDMS microfluidic devices to dissipate air bubbles and guide the biofabrication of biopolymer membranes. Vacuuming through PDMS was simply achieved by either withdrawing a syringe or releasing a squeezed nasal aspirator. Upon vacuuming, air bubbles dissipated within minutes, membranes were effortlessly formed, and the add-on vacuum layer can be removed. Subsequent membrane growth could be robustly controlled with the flows and pH of solutions. This new process is user-friendly and has achieved a 100% success rate in more than 200 trials in membrane biofabrication.
Collapse
Affiliation(s)
- Phu Pham
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| | - Thanh Vo
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| | - Xiaolong Luo
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| |
Collapse
|
43
|
Abstract
Various concentration gradient generation methods based on microfluidic systems are summarized in this paper.
Collapse
Affiliation(s)
- Xiang Wang
- College of Mechanical Engineering and Applied Electronics Technology
- Beijing University of Technology
- Beijing 100124
- China
| | - Zhaomiao Liu
- College of Mechanical Engineering and Applied Electronics Technology
- Beijing University of Technology
- Beijing 100124
- China
| | - Yan Pang
- College of Mechanical Engineering and Applied Electronics Technology
- Beijing University of Technology
- Beijing 100124
- China
| |
Collapse
|
44
|
Abstract
This paper demonstrates the generation of enzyme free DNA reaction–diffusion gradientsin vitrothat remain stable for tens of hours.
Collapse
Affiliation(s)
- John Zenk
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
| | - Dominic Scalise
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
| | - Kaiyuan Wang
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
| | - Phillip Dorsey
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
| | - Joshua Fern
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
| | - Ariana Cruz
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
| | - Rebecca Schulman
- Chemical and Biomolecular Engineering
- Johns Hopkins University
- Baltimore
- USA
- Computer Science
| |
Collapse
|
45
|
Abstract
This work describes a novel microfluidic device capable of generating multi-profile gradients that include sigmoidal, parabolic, and exponential concentration variations across its main channel.
Collapse
Affiliation(s)
- A. Menachery
- Division of Engineering
- New York University Abu Dhabi
- Abu Dhabi
- United Arab Emirates
| | - N. Kumawat
- Division of Engineering
- New York University Abu Dhabi
- Abu Dhabi
- United Arab Emirates
| | - M. A. Qasaimeh
- Division of Engineering
- New York University Abu Dhabi
- Abu Dhabi
- United Arab Emirates
- Department of Mechanical and Aerospace Engineering
| |
Collapse
|
46
|
Wolfram CJ, Rubloff GW, Luo X. Perspectives in flow-based microfluidic gradient generators for characterizing bacterial chemotaxis. Biomicrofluidics 2016; 10:061301. [PMID: 27917249 PMCID: PMC5106431 DOI: 10.1063/1.4967777] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Accepted: 10/31/2016] [Indexed: 05/08/2023]
Abstract
Chemotaxis is a phenomenon which enables cells to sense concentrations of certain chemical species in their microenvironment and move towards chemically favorable regions. Recent advances in microbiology have engineered the chemotactic properties of bacteria to perform novel functions, but traditional methods of characterizing chemotaxis do not fully capture the associated cell motion, making it difficult to infer mechanisms that link the motion to the microbiology which induces it. Microfluidics offers a potential solution in the form of gradient generators. Many of the gradient generators studied to date for this application are flow-based, where a chemical species diffuses across the laminar flow interface between two solutions moving through a microchannel. Despite significant research efforts, flow-based gradient generators have achieved mixed success at accurately capturing the highly subtle chemotactic responses exhibited by bacteria. Here we present an analysis encompassing previously published versions of flow-based gradient generators, the theories that govern their gradient-generating properties, and new, more practical considerations that result from experimental factors. We conclude that flow-based gradient generators present a challenge inherent to their design in that the residence time and gradient decay must be finely balanced, and that this significantly narrows the window for reliable observation and quantification of chemotactic motion. This challenge is compounded by the effects of shear on an ellipsoidal bacterium that causes it to preferentially align with the direction of flow and subsequently suppresses the cross-flow chemotactic response. These problems suggest that a static, non-flowing gradient generator may be a more suitable platform for chemotaxis studies in the long run, despite posing greater difficulties in design and fabrication.
Collapse
Affiliation(s)
- Christopher J Wolfram
- Department of Materials Science and Engineering, University of Maryland , College Park, Maryland 20742, USA
| | - Gary W Rubloff
- Department of Materials Science and Engineering, University of Maryland , College Park, Maryland 20742, USA
| | - Xiaolong Luo
- Department of Mechanical Engineering, The Catholic University of America , Washington, DC 20064, USA
| |
Collapse
|
47
|
Murugesan N, Panda T, Das SK. E. coli DH5α cell response to a sudden change in microfluidic chemical environment. Annu Int Conf IEEE Eng Med Biol Soc 2016; 2015:3213-6. [PMID: 26736976 DOI: 10.1109/embc.2015.7319076] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Motile bacteria respond to changing chemical environment by moving towards or away from a particular location. Bacterial migration under chemical gradient is one of the most studied areas in biomedical field. In this work we looked into how bacterial cells respond to sudden change in the microfluidic chemical environment. E. coli DH5α cells were subjected to an attractant gradient (0.1 mM sorbitol--attractant to E. coli cells) and after 120 min the same cells were exposed to an inhibitor (0.1 mM NiSO4) gradient in the same microfluidic device. Our studies revealed that when the E. coli DH5α cells were exposed to 0.1 mM sorbitol, they showed faster chemotaxis towards the attractant (0.1 mM sorbitol) and achieved steady state by 60 min. When we replaced 0.1 mM sorbitol with 0.1 mM NiSO4 in the device we found that that the E. coli DH5α cells started responding to change in chemical environment within 10 min and achieved steady state at the end of 60 min. This shows that the bacterial cells respond to change in local chemical environment is within few minutes.
Collapse
|
48
|
Shin S, Ahmed I, Hwang J, Seo Y, Lee E, Choi J, Moon S, Hong JW. A Microfluidic Approach to Investigating a Synergistic Effect of Tobramycin and Sodium Dodecyl Sulfate on Pseudomonas aeruginosa Biofilms. ANAL SCI 2016; 32:67-73. [PMID: 26753708 DOI: 10.2116/analsci.32.67] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In recent years, a microfluidic technology has contributed a significant role in biological research, specifically for the study of biofilms. Bacterial biofilms are a source of infections and contamination in the environment due to an extra polymeric matrix. Inadequate uses of antibiotics make the bacterial biofilms antibiotic resistant. Therefore, it is important to determine the effective concentration of antibiotics in order to eliminate bacterial biofilms. The present microfluidic study was carried out to analyze the activities of tobramycin and sodium dodecyl sulfate (SDS) against Pseudomonas aeruginosa biofilms with a continuous flow in order to achieve a greater delivery of the agents. The results show that a co-treatment of tobramycin and SDS significantly reduced the biomass of biofilms (by more than 99%) after 24 h. Tobramycin and SDS killed and detached bacteria in the cores of biofilms. Evidently, our data suggest that a microchannel would be effective for both quantitative and qualitative evaluations in order to test combinatorial effect of drugs and chemicals on a complexed biological system including biofilm.
Collapse
Affiliation(s)
- Soojeong Shin
- Department of Bionano Engineering, Hanyang University
| | | | | | | | | | | | | | | |
Collapse
|
49
|
Luo X, Vo T, Jambi F, Pham P, Choy JS. Microfluidic partition with in situ biofabricated semipermeable biopolymer membranes for static gradient generation. Lab Chip 2016; 16:3815-3823. [PMID: 27713976 DOI: 10.1039/c6lc00742b] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We report an in situ biofabrication strategy that conveniently partitions microfluidic networks into physically separated while chemically communicating microchannels with semipermeable biopolymer membranes, which enable the facile generation of static gradients for biomedical applications. The biofabrication of parallel biopolymer membranes was initiated with the dissipation of trapped air bubbles in parallel apertures in polydimethylsiloxane (PDMS) microfluidic devices, followed by tunable membrane growth with precise temporal and spatial control to the desired thickness. Static gradients were generated within minutes and well maintained over time by pure diffusion of molecules through the biofabricated semipermeable membranes. As an example application, the static gradient of alpha factor was generated to study the development of the "shmoo" morphology of yeast over time. The in situ biofabrication provides a simple approach to generate static gradients and an ideal platform for biological applications where flow-free static gradients are indispensable.
Collapse
Affiliation(s)
- Xiaolong Luo
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| | - Thanh Vo
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| | - Fahad Jambi
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| | - Phu Pham
- Department of Mechanical Engineering, The Catholic University of America, Washington, D.C. 20064, USA.
| | - John S Choy
- Department of Biology, The Catholic University of America, Washington, D.C. 20064, USA
| |
Collapse
|
50
|
Oliveira AF, Pessoa ACSN, Bastos RG, de la Torre LG. Microfluidic tools toward industrial biotechnology. Biotechnol Prog 2016; 32:1372-1389. [DOI: 10.1002/btpr.2350] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 08/15/2016] [Indexed: 01/29/2023]
Affiliation(s)
- Aline F. Oliveira
- Department of Bioprocesses and Materials Engineering, School of Chemical Engineering, University of Campinas; 500 Albert Einstein avenue Campinas P.O. Box 6066
| | - Amanda C. S. N. Pessoa
- Department of Bioprocesses and Materials Engineering, School of Chemical Engineering, University of Campinas; 500 Albert Einstein avenue Campinas P.O. Box 6066
| | - Reinaldo G. Bastos
- Department of Agroindustrial Technology and Rural Socioeconomy, Center of Agricultural Sciences, Federal University of São Carlos; Km 174 Anhanguera Highway Araras P.O. Box 153
| | - Lucimara G. de la Torre
- Department of Bioprocesses and Materials Engineering, School of Chemical Engineering, University of Campinas; 500 Albert Einstein avenue Campinas P.O. Box 6066
| |
Collapse
|