1
|
Wang H, Guo J, Zhang Y, Fu Z, Yao Y. Closed-loop rehabilitation of upper-limb dyskinesia after stroke: from natural motion to neuronal microfluidics. J Neuroeng Rehabil 2025; 22:87. [PMID: 40253334 PMCID: PMC12008995 DOI: 10.1186/s12984-025-01617-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2024] [Accepted: 03/27/2025] [Indexed: 04/21/2025] Open
Abstract
This review proposes an innovative closed-loop rehabilitation strategy that integrates multiple subdomains of stroke science to address the global challenge of upper-limb dyskinesia post-stroke. Despite advancements in neural remodeling and rehabilitation research, the compartmentalization of subdomains has limited the effectiveness of current rehabilitation strategies. Our approach unites key areas-including the post-stroke brain, upper-limb rehabilitation robotics, motion sensing, metrics, neural microfluidics, and neuroelectronics-into a cohesive framework designed to enhance upper-limb motion rehabilitation outcomes. By leveraging cutting-edge technologies such as lightweight rehabilitation robotics, advanced motion sensing, and neural microfluidic models, this strategy enables real-time monitoring, adaptive interventions, and personalized rehabilitation plans. Furthermore, we explore the potential of closed-loop systems to drive neural plasticity and functional recovery, offering a transformative perspective on stroke rehabilitation. Finally, we discuss future directions, emphasizing the integration of emerging technologies and interdisciplinary collaboration to advance the field. This review highlights the promise of closed-loop strategies in achieving unprecedented integration of subdomains and improving post-stroke upper-limb rehabilitation outcomes.
Collapse
Affiliation(s)
- Honggang Wang
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, China
| | - Junlong Guo
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, China
| | - Yangqi Zhang
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, China
| | - Ze Fu
- Institute of Biological and Medical Technology, Harbin Institute of Technology (Weihai), Weihai, 264200, China
| | - Yufeng Yao
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, China.
| |
Collapse
|
2
|
Amos G, Ihle SJ, Clément BF, Duru J, Girardin S, Maurer B, Delipinar T, Vörös J, Ruff T. Engineering an in vitro retinothalamic nerve model. Front Neurosci 2024; 18:1396966. [PMID: 38835836 PMCID: PMC11148348 DOI: 10.3389/fnins.2024.1396966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/03/2024] [Indexed: 06/06/2024] Open
Abstract
Understanding the retinogeniculate pathway in vitro can offer insights into its development and potential for future therapeutic applications. This study presents a Polydimethylsiloxane-based two-chamber system with axon guidance channels, designed to replicate unidirectional retinogeniculate signal transmission in vitro. Using embryonic rat retinas, we developed a model where retinal spheroids innervate thalamic targets through up to 6 mm long microfluidic channels. Using a combination of electrical stimulation and functional calcium imaging we assessed how channel length and electrical stimulation frequency affects thalamic target response. In the presented model we integrated up to 20 identical functional retinothalamic neural networks aligned on a single transparent microelectrode array, enhancing the robustness and quality of recorded functional data. We found that network integrity depends on channel length, with 0.5-2 mm channels maintaining over 90% morphological and 50% functional integrity. A reduced network integrity was recorded in longer channels. The results indicate a notable reduction in forward spike propagation in channels longer than 4 mm. Additionally, spike conduction fidelity decreased with increasing channel length. Yet, stimulation-induced thalamic target activity remained unaffected by channel length. Finally, the study found that a sustained thalamic calcium response could be elicited with stimulation frequencies up to 31 Hz, with higher frequencies leading to transient responses. In conclusion, this study presents a high-throughput platform that demonstrates how channel length affects retina to brain network formation and signal transmission in vitro.
Collapse
Affiliation(s)
- Giulia Amos
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Stephan J Ihle
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Blandine F Clément
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Jens Duru
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Sophie Girardin
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Benedikt Maurer
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Tuğçe Delipinar
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - János Vörös
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| | - Tobias Ruff
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland
| |
Collapse
|
3
|
Mateus JC, Sousa MM, Burrone J, Aguiar P. Beyond a Transmission Cable-New Technologies to Reveal the Richness in Axonal Electrophysiology. J Neurosci 2024; 44:e1446232023. [PMID: 38479812 PMCID: PMC10941245 DOI: 10.1523/jneurosci.1446-23.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 03/17/2024] Open
Abstract
The axon is a neuronal structure capable of processing, encoding, and transmitting information. This assessment contrasts with a limiting, but deeply rooted, perspective where the axon functions solely as a transmission cable of somatodendritic activity, sending signals in the form of stereotypical action potentials. This perspective arose, at least partially, because of the technical difficulties in probing axons: their extreme length-to-diameter ratio and intricate growth paths preclude the study of their dynamics through traditional techniques. Recent findings are challenging this view and revealing a much larger repertoire of axonal computations. Axons display complex signaling processes and structure-function relationships, which can be modulated via diverse activity-dependent mechanisms. Additionally, axons can exhibit patterns of activity that are dramatically different from those of their corresponding soma. Not surprisingly, many of these recent discoveries have been driven by novel technology developments, which allow for in vitro axon electrophysiology with unprecedented spatiotemporal resolution and signal-to-noise ratio. In this review, we outline the state-of-the-art in vitro toolset for axonal electrophysiology and summarize the recent discoveries in axon function it has enabled. We also review the increasing repertoire of microtechnologies for controlling axon guidance which, in combination with the available cutting-edge electrophysiology and imaging approaches, have the potential for more controlled and high-throughput in vitro studies. We anticipate that a larger adoption of these new technologies by the neuroscience community will drive a new era of experimental opportunities in the study of axon physiology and consequently, neuronal function.
Collapse
Affiliation(s)
- J C Mateus
- i3S- Instituto de Investigação e Inovação em Saúde, Universidade do Porto, 4200-135 Porto, Portugal
| | - M M Sousa
- i3S- Instituto de Investigação e Inovação em Saúde, Universidade do Porto, 4200-135 Porto, Portugal
| | - J Burrone
- MRC Centre for Neurodevelopmental Disorders, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London SE1 1UL, United Kingdom
- Centre for Developmental Neurobiology, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London SE1 1UL, United Kingdom
| | - P Aguiar
- i3S- Instituto de Investigação e Inovação em Saúde, Universidade do Porto, 4200-135 Porto, Portugal
| |
Collapse
|
4
|
Lefebvre C, Vreulx AC, Dumortier C, Bégard S, Gelle C, Siedlecki-Wullich D, Colin M, Kilinc D, Halliez S. Integration of Microfluidic Devices with Microelectrode Arrays to Functionally Assay Amyloid-β-Induced Synaptotoxicity. ACS Biomater Sci Eng 2024; 10:1856-1868. [PMID: 38385618 DOI: 10.1021/acsbiomaterials.3c00997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Alzheimer's disease (AD) is a neurodegenerative disease and the most frequent cause of dementia. It is characterized by the accumulation in the brain of two pathological protein aggregates: amyloid-β peptides (Aβ) and abnormally phosphorylated tau. The progressive cognitive decline observed in patients strongly correlates with the synaptic loss. Many lines of evidence suggest that soluble forms of Aβ accumulate into the brain where they cause synapse degeneration. Stopping their spreading and/or targeting the pathophysiological mechanisms leading to synaptic loss would logically be beneficial for the patients. However, we are still far from understanding these processes. Our objective was therefore to develop a versatile model to assay and study Aβ-induced synaptotoxicity. We integrated a microfluidic device that physically isolates synapses from presynaptic and postsynaptic neurons with a microelectrode array. We seeded mouse primary cortical cells in the presynaptic and postsynaptic chambers. After functional synapses have formed in the synaptic chamber, we exposed them to concentrated conditioned media from cell lines overexpressing the wild-type or mutated amyloid precursor protein and thus secreting different levels of Aβ. We recorded the neuronal activity before and after exposition to Aβ and quantified Aβ's effects on the connectivity between presynaptic and postsynaptic neurons. We observed that the application of Aβ on the synapses for 48 h strongly decreased the interchamber connectivity without significantly affecting the neuronal activity in the presynaptic or postsynaptic chambers. Thus, through this model, we are able to functionally assay the impact of Aβ peptides (or other molecules) on synaptic connectivity and to use the latter as a proxy to study Aβ-induced synaptotoxicity. Moreover, since the presynaptic, postsynaptic, and synaptic chambers can be individually targeted, our assay provides a powerful tool to evaluate the involvement of candidate genes in synaptic vulnerability and/or test therapeutic strategies for AD.
Collapse
Affiliation(s)
- Camille Lefebvre
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Anaïs-Camille Vreulx
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Corentin Dumortier
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Séverine Bégard
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Carla Gelle
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Dolores Siedlecki-Wullich
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Morvane Colin
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| | - Devrim Kilinc
- Université de Lille, Institut Pasteur de Lille, CHU Lille, INSERM U1167, LabEx DISTALZ, 59019Lille ,France
| | - Sophie Halliez
- Université de Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, F-59000 Lille, France
| |
Collapse
|
5
|
Buentello DC, Garcia-Corral M, Trujillo-de Santiago G, Alvarez MM. Neuron(s)-on-a-Chip: A Review of the Design and Use of Microfluidic Systems for Neural Tissue Culture. IEEE Rev Biomed Eng 2024; 17:243-263. [PMID: 36301779 DOI: 10.1109/rbme.2022.3217486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Neuron-on-chip (NoC) systems-microfluidic devices in which neurons are cultured-have become a promising alternative to replace or minimize the use of animal models and have greatly facilitated in vitro research. Here, we review and discuss current developments in neuron-on-chip platforms, with a particular emphasis on existing biological models, culturing techniques, biomaterials, and topologies. We also discuss how the architecture, flow, and gradients affect neuronal growth, differentiation, and development. Finally, we discuss some of the most recent applications of NoCs in fundamental research (i.e., studies on the effects of electrical, mechanical/topological, or chemical stimuli) and in disease modeling.
Collapse
|
6
|
Lee H, Yi GS, Nam Y. Connectivity and network burst properties of in-vitro neuronal networks induced by a clustered structure with alginate hydrogel patterning. Biomed Eng Lett 2023; 13:659-670. [PMID: 37872997 PMCID: PMC10590365 DOI: 10.1007/s13534-023-00289-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/19/2023] [Accepted: 05/22/2023] [Indexed: 10/25/2023] Open
Abstract
Modularity is one of the important structural properties that affect information processing and other functionalities of neuronal networks. Researchers have developed in-vitro clustered network models for reproducing the modularity, but it is still challenging to control the segregation and integration of several sub-populations of them. We cultured clustered networks with alginate patterning and collected the electrophysiological signals to investigate the changes in functional properties during the development. We built inter-connected neuronal clusters using alginate micro-patterning with a circular shape on the surface of the micro-electrode array. The neuronal clusters were enabled to be connected at 3 or 10 days-in-vitro (DIV) by removing the barrier. The neuronal signals from different types of networks were collected from 16 to 34 DIV, and functional characteristics were examined. Connectivity and burst motif analysis were carried out to find out the relation between the structure and function of the networks. Neuronal networks with clustered structure showed different activity properties from the random networks along the development. The clustered networks had more short-range connections compared to the random networks. In the network burst motif analysis, the clustered networks showed more various patterns and a slower propagation of the activation patterns. In this study, we successfully cultured neuronal networks with clustered structure, and the structure affected the functional properties. The network model suggested in this study will be a good solution for observing the effect of structure on function during their development. Supplementary Information The online version contains supplementary material available at 10.1007/s13534-023-00289-5.
Collapse
Affiliation(s)
- Hyungsub Lee
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141 Republic of Korea
| | - Gwan-Su Yi
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141 Republic of Korea
| | - Yoonkey Nam
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141 Republic of Korea
- KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141 Republic of Korea
| |
Collapse
|
7
|
Dupuit V, Briançon-Marjollet A, Delacour C. Portrait of intense communications within microfluidic neural networks. Sci Rep 2023; 13:12306. [PMID: 37516789 PMCID: PMC10387102 DOI: 10.1038/s41598-023-39477-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/26/2023] [Indexed: 07/31/2023] Open
Abstract
In vitro model networks could provide cellular models of physiological relevance to reproduce and investigate the basic function of neural circuits on a chip in the laboratory. Several tools and methods have been developed since the past decade to build neural networks on a chip; among them, microfluidic circuits appear to be a highly promising approach. One of the numerous advantages of this approach is that it preserves stable somatic and axonal compartments over time due to physical barriers that prevent the soma from exploring undesired areas and guide neurites along defined pathways. As a result, neuron compartments can be identified and isolated, and their interconnectivity can be modulated to build a topological neural network (NN). Here, we have assessed the extent to which the confinement imposed by the microfluidic environment can impact cell development and shape NN activity. Toward that aim, microelectrode arrays have enabled the monitoring of the short- and mid-term evolution of neuron activation over the culture period at specific locations in organized (microfluidic) and random (control) networks. In particular, we have assessed the spike and burst rate, as well as the correlations between the extracted spike trains over the first stages of maturation. This study enabled us to observe intense neurite communications that would have been weaker and more delayed within random networks; the spiking rate, burst and correlations being reinforced over time in terms of number and amplitude, exceeding the electrophysiological features of standard cultures. Beyond the enhanced detection efficiency that was expected from the microfluidic channels, the confinement of cells seems to reinforce neural communications and cell development throughout the network.
Collapse
Affiliation(s)
- Victor Dupuit
- Institut Néel, University Grenoble Alpes, CNRS, Grenoble INP, 38000, Grenoble, France
| | - Anne Briançon-Marjollet
- HP2 Laboratory, University Grenoble Alpes, Institut National de la Santé et de la Recherche Médicale U1300, Grenoble, France
| | - Cécile Delacour
- Institut Néel, University Grenoble Alpes, CNRS, Grenoble INP, 38000, Grenoble, France.
| |
Collapse
|
8
|
Xu S, Liu Y, Yang Y, Zhang K, Liang W, Xu Z, Wu Y, Luo J, Zhuang C, Cai X. Recent Progress and Perspectives on Neural Chip Platforms Integrating PDMS-Based Microfluidic Devices and Microelectrode Arrays. MICROMACHINES 2023; 14:709. [PMID: 37420942 PMCID: PMC10145465 DOI: 10.3390/mi14040709] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 03/17/2023] [Accepted: 03/19/2023] [Indexed: 07/09/2023]
Abstract
Recent years have witnessed a spurt of progress in the application of the encoding and decoding of neural activities to drug screening, diseases diagnosis, and brain-computer interactions. To overcome the constraints of the complexity of the brain and the ethical considerations of in vivo research, neural chip platforms integrating microfluidic devices and microelectrode arrays have been raised, which can not only customize growth paths for neurons in vitro but also monitor and modulate the specialized neural networks grown on chips. Therefore, this article reviews the developmental history of chip platforms integrating microfluidic devices and microelectrode arrays. First, we review the design and application of advanced microelectrode arrays and microfluidic devices. After, we introduce the fabrication process of neural chip platforms. Finally, we highlight the recent progress on this type of chip platform as a research tool in the field of brain science and neuroscience, focusing on neuropharmacology, neurological diseases, and simplified brain models. This is a detailed and comprehensive review of neural chip platforms. This work aims to fulfill the following three goals: (1) summarize the latest design patterns and fabrication schemes of such platforms, providing a reference for the development of other new platforms; (2) generalize several important applications of chip platforms in the field of neurology, which will attract the attention of scientists in the field; and (3) propose the developmental direction of neural chip platforms integrating microfluidic devices and microelectrode arrays.
Collapse
Affiliation(s)
- Shihong Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yaoyao Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yan Yang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Kui Zhang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Liang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhaojie Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yirong Wu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jinping Luo
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chengyu Zhuang
- Department of Orthopaedics, Rujing Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
9
|
Goshi N, Girardi G, da Costa Souza F, Gardner A, Lein PJ, Seker E. Influence of microchannel geometry on device performance and electrophysiological recording fidelity during long-term studies of connected neural populations. LAB ON A CHIP 2022; 22:3961-3975. [PMID: 36111641 PMCID: PMC9639432 DOI: 10.1039/d2lc00683a] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Compartmentalized microfluidic neural cell culture platforms, which physically separate axons from the neural soma using a series of microchannels, have been used for studying a wide range of pathological conditions and basic neuroscience questions. While each study has different experimental needs, the fundamental design of these devices has largely remained unchanged and a systematic study to establish long-term neural cultures in this format is lacking. Here, we investigate the influence of microchannel geometry and cell seeding density on device performance particularly in the context of long-term studies of synaptically-connected, yet fluidically-isolated neural populations of neurons and glia. Of the different experimental parameters, the microchannel height was the principal determinant of device performance, where the other parameters offer additional degrees of freedom in customizing such devices for specific applications. We condense the effects of these parameters into design rules and demonstrate their utility in engineering a microfluidic neural culture platform with integrated microelectrode arrays. The engineered device successfully recorded from primary rat cortical cells for 59 days in vitro with more than on order of magnitude enhancement in signal-to-noise ratio in the microchannels.
Collapse
Affiliation(s)
- Noah Goshi
- Department of Biomedical Engineering, University of California - Davis, Davis, CA 95616, USA
| | - Gregory Girardi
- Department of Biomedical Engineering, University of California - Davis, Davis, CA 95616, USA
| | - Felipe da Costa Souza
- Department of Molecular Biosciences, University of California - Davis, Davis, CA 95616, USA
| | - Alexander Gardner
- Department of Electrical and Computer Engineering, University of California - Davis, Davis, CA 95616, USA.
| | - Pamela J Lein
- Department of Molecular Biosciences, University of California - Davis, Davis, CA 95616, USA
| | - Erkin Seker
- Department of Electrical and Computer Engineering, University of California - Davis, Davis, CA 95616, USA.
| |
Collapse
|
10
|
Functional Characterization of Human Pluripotent Stem Cell-Derived Models of the Brain with Microelectrode Arrays. Cells 2021; 11:cells11010106. [PMID: 35011667 PMCID: PMC8750870 DOI: 10.3390/cells11010106] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/22/2021] [Accepted: 12/24/2021] [Indexed: 12/26/2022] Open
Abstract
Human pluripotent stem cell (hPSC)-derived neuron cultures have emerged as models of electrical activity in the human brain. Microelectrode arrays (MEAs) measure changes in the extracellular electric potential of cell cultures or tissues and enable the recording of neuronal network activity. MEAs have been applied to both human subjects and hPSC-derived brain models. Here, we review the literature on the functional characterization of hPSC-derived two- and three-dimensional brain models with MEAs and examine their network function in physiological and pathological contexts. We also summarize MEA results from the human brain and compare them to the literature on MEA recordings of hPSC-derived brain models. MEA recordings have shown network activity in two-dimensional hPSC-derived brain models that is comparable to the human brain and revealed pathology-associated changes in disease models. Three-dimensional hPSC-derived models such as brain organoids possess a more relevant microenvironment, tissue architecture and potential for modeling the network activity with more complexity than two-dimensional models. hPSC-derived brain models recapitulate many aspects of network function in the human brain and provide valid disease models, but certain advancements in differentiation methods, bioengineering and available MEA technology are needed for these approaches to reach their full potential.
Collapse
|
11
|
Prasanna P, Rathee S, Rahul V, Mandal D, Chandra Goud MS, Yadav P, Hawthorne S, Sharma A, Gupta PK, Ojha S, Jha NK, Villa C, Jha SK. Microfluidic Platforms to Unravel Mysteries of Alzheimer's Disease: How Far Have We Come? Life (Basel) 2021; 11:life11101022. [PMID: 34685393 PMCID: PMC8537508 DOI: 10.3390/life11101022] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 09/16/2021] [Accepted: 09/20/2021] [Indexed: 12/12/2022] Open
Abstract
Alzheimer’s disease (AD) is a significant health concern with enormous social and economic impact globally. The gradual deterioration of cognitive functions and irreversible neuronal losses are primary features of the disease. Even after decades of research, most therapeutic options are merely symptomatic, and drugs in clinical practice present numerous side effects. Lack of effective diagnostic techniques prevents the early prognosis of disease, resulting in a gradual deterioration in the quality of life. Furthermore, the mechanism of cognitive impairment and AD pathophysiology is poorly understood. Microfluidics exploits different microscale properties of fluids to mimic environments on microfluidic chip-like devices. These miniature multichambered devices can be used to grow cells and 3D tissues in vitro, analyze cell-to-cell communication, decipher the roles of neural cells such as microglia, and gain insights into AD pathophysiology. This review focuses on the applications and impact of microfluidics on AD research. We discuss the technical challenges and possible solutions provided by this new cutting-edge technique to understand disease-associated pathways and mechanisms.
Collapse
Affiliation(s)
- Pragya Prasanna
- School of Applied Sciences, KK University, Nalanda 803115, Bihar, India;
- Correspondence: or (P.P.); (S.K.J.)
| | - Shweta Rathee
- Department of Food Science and Technology, National Institute of Food Technology, Entrepreneurship and Management, Sonipat 131028, Haryana, India;
| | - Vedanabhatla Rahul
- Department of Mechanical Engineering, National Institute of Technology, Rourkela 769008, Odisha, India;
| | - Debabrata Mandal
- Department of Biotechnology, National Institute of Pharmaceutical Education and Research, Hajipur 844101, Bihar, India;
| | | | - Pardeep Yadav
- Department of Biotechnology, School of Engineering and Technology (SET), Sharda University, Greater Noida 201310, Uttar Pradesh, India; (P.Y.); (N.K.J.)
| | - Susan Hawthorne
- School of Pharmacy and Pharmaceutical Sciences, Ulster University, Cromore Road, Coleraine, Co., Londonderry BT52 1SA, UK;
| | - Ankur Sharma
- Department of Life Sciences, School of Basic Science and Research (SBSR), Sharda University, Greater Noida 201310, Uttar Pradesh, India; (A.S.); (P.K.G.)
| | - Piyush Kumar Gupta
- Department of Life Sciences, School of Basic Science and Research (SBSR), Sharda University, Greater Noida 201310, Uttar Pradesh, India; (A.S.); (P.K.G.)
| | - Shreesh Ojha
- Department of Pharmacology and Therapeutics, College of Medicine and Health Sciences, P.O. Box 17666, United Arab Emirates University, Al Ain 15551, United Arab Emirates;
| | - Niraj Kumar Jha
- Department of Biotechnology, School of Engineering and Technology (SET), Sharda University, Greater Noida 201310, Uttar Pradesh, India; (P.Y.); (N.K.J.)
| | - Chiara Villa
- School of Medicine and Surgery, University of Milano-Bicocca, 20900 Monza, Italy;
| | - Saurabh Kumar Jha
- Department of Biotechnology, School of Engineering and Technology (SET), Sharda University, Greater Noida 201310, Uttar Pradesh, India; (P.Y.); (N.K.J.)
- Correspondence: or (P.P.); (S.K.J.)
| |
Collapse
|
12
|
Brofiga M, Pisano M, Raiteri R, Massobrio P. On the road to the brain-on-a-chip: a review on strategies, methods, and applications. J Neural Eng 2021; 18. [PMID: 34280903 DOI: 10.1088/1741-2552/ac15e4] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 07/19/2021] [Indexed: 11/12/2022]
Abstract
The brain is the most complex organ of our body. Such a complexity spans from the single-cell morphology up to the intricate connections that hundreds of thousands of neurons establish to create dense neuronal networks. All these components are involved in the genesis of the rich patterns of electrophysiological activity that characterize the brain. Over the years, researchers coming from different disciplines developedin vitrosimplified experimental models to investigate in a more controllable and observable way how neuronal ensembles generate peculiar firing rhythms, code external stimulations, or respond to chemical drugs. Nowadays, suchin vitromodels are namedbrain-on-a-chippointing out the relevance of the technological counterpart as artificial tool to interact with the brain: multi-electrode arrays are well-used devices to record and stimulate large-scale developing neuronal networks originated from dissociated cultures, brain slices, up to brain organoids. In this review, we will discuss the state of the art of the brain-on-a-chip, highlighting which structural and biological features a realisticin vitrobrain should embed (and how to achieve them). In particular, we identified two topological features, namely modular and three-dimensional connectivity, and a biological one (heterogeneity) that takes into account the huge number of neuronal types existing in the brain. At the end of this travel, we will show how 'far' we are from the goal and how interconnected-brain-regions-on-a-chip is the most appropriate wording to indicate the current state of the art.
Collapse
Affiliation(s)
- Martina Brofiga
- Department of Informatics, Bioengineering, Robotics, and Systems Engineering (DIBRIS), University of Genova, Genova, Italy
| | - Marietta Pisano
- Department of Informatics, Bioengineering, Robotics, and Systems Engineering (DIBRIS), University of Genova, Genova, Italy
| | - Roberto Raiteri
- Department of Informatics, Bioengineering, Robotics, and Systems Engineering (DIBRIS), University of Genova, Genova, Italy.,CNR- Institute of Biophysics, Genova, Italy
| | - Paolo Massobrio
- Department of Informatics, Bioengineering, Robotics, and Systems Engineering (DIBRIS), University of Genova, Genova, Italy.,National Institute for Nuclear Physics (INFN), Genova, Italy
| |
Collapse
|
13
|
Shimba K, Kotani K, Jimbo Y. Microfabricated Device to Record Axonal Conduction Under Pharmacological Treatment for Functional Evaluation of Axon Ion Channel. IEEE Trans Biomed Eng 2021; 68:3574-3581. [PMID: 33970856 DOI: 10.1109/tbme.2021.3078473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Neuronal networks are fundamental structures for information processing in the central nervous system. This processing function is severely impaired by abnormal axonal conduction from changes in functional ion channel expression. The evaluation of axonal conduction properties can be effective in the early diagnosis of information-processing abnormalities. However, little is known about functional ion channel expression in axons owing to lack of an appropriate method. In this study, we developed a device to measure changes in axonal conduction properties by selective pharmacological stimulation for the functional evaluation of Na channels expressed in axons. METHODS Axons of rat cortical neurons were guided across a pair of electrodes through microtunnel structures by employing surface patterning. RESULTS The developed device detected more than 50 axons while recording for 10 min. The conduction delay along the axons decreased by 22.5% with neuron maturation. Tetrodotoxin and lidocaine (Na channel blockers) increased the conduction delay in a concentration-dependent manner depending on their working concentrations, indicating the effectiveness of the device. Finally, selective Na channel blockers for various Na channel subtypes were used. Phrixotoxin, a Nav1.2 blocker, markedly increased the conduction delay, suggesting that Nav1.2 is functionally expressed in the unmyelinated axons of the cerebral cortex. CONCLUSION These results show that our device is feasible for the high-throughput functional evaluation of Na channel subtypes in axons. SIGNIFICANCE The results obtained can contribute to the understanding of the pathogenic mechanisms of neurological diseases that involve changes in the functional expression states of ion channels in axons.
Collapse
|
14
|
Park MU, Bae Y, Lee KS, Song JH, Lee SM, Yoo KH. Collective dynamics of neuronal activities in various modular networks. LAB ON A CHIP 2021; 21:951-961. [PMID: 33475100 DOI: 10.1039/d0lc01106a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Modularity is a key feature of structural and functional brain networks. However, the association between the structure and function of modular brain networks has not been revealed. We constructed three types of modular cortical networks in vitro and investigated their neuronal activities. The modular networks comprising 4, 3, or 2 modules were constructed using polydimethylsiloxane (PDMS) microstructures fabricated directly on a multi-electrode array (MEA) without transfer. The 4-module network had the strongest modular connectivity, followed by the 3-module and 2-module networks. To investigate how neuronal activities were affected by the modular network structure, spontaneous neuronal activities were recorded on different days in vitro and analyzed based on spike amplitudes, network bursts, and the propagation properties of individual spikes. Different characteristics were observed depending on the network topology and modular connectivity. Moreover, when an electrode was stimulated by biphasic voltage pulses, bursts were elicited for the 4-module network, whereas spikes were elicited for the 3-module and 2-module networks. Direct fabrication of the PDMS microstructures on the MEA without transfer allows microscale construction of modular networks and high-density functional recording; therefore, the technique utilizing the PDMS microstructures can be applied to the systematic study of the dynamics of modular neuronal networks in vitro.
Collapse
Affiliation(s)
- Myung Uk Park
- Department of Physics, Yonsei University, Seoul 03722, Republic of Korea.
| | | | | | | | | | | |
Collapse
|
15
|
Pelkonen A, Mzezewa R, Sukki L, Ryynänen T, Kreutzer J, Hyvärinen T, Vinogradov A, Aarnos L, Lekkala J, Kallio P, Narkilahti S. A modular brain-on-a-chip for modelling epileptic seizures with functionally connected human neuronal networks. Biosens Bioelectron 2020; 168:112553. [DOI: 10.1016/j.bios.2020.112553] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 08/01/2020] [Accepted: 08/23/2020] [Indexed: 12/22/2022]
|
16
|
Ferrari E, Palma C, Vesentini S, Occhetta P, Rasponi M. Integrating Biosensors in Organs-on-Chip Devices: A Perspective on Current Strategies to Monitor Microphysiological Systems. BIOSENSORS 2020; 10:E110. [PMID: 32872228 PMCID: PMC7558092 DOI: 10.3390/bios10090110] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 08/25/2020] [Accepted: 08/26/2020] [Indexed: 01/20/2023]
Abstract
Organs-on-chip (OoC), often referred to as microphysiological systems (MPS), are advanced in vitro tools able to replicate essential functions of human organs. Owing to their unprecedented ability to recapitulate key features of the native cellular environments, they represent promising tools for tissue engineering and drug screening applications. The achievement of proper functionalities within OoC is crucial; to this purpose, several parameters (e.g., chemical, physical) need to be assessed. Currently, most approaches rely on off-chip analysis and imaging techniques. However, the urgent demand for continuous, noninvasive, and real-time monitoring of tissue constructs requires the direct integration of biosensors. In this review, we focus on recent strategies to miniaturize and embed biosensing systems into organs-on-chip platforms. Biosensors for monitoring biological models with metabolic activities, models with tissue barrier functions, as well as models with electromechanical properties will be described and critically evaluated. In addition, multisensor integration within multiorgan platforms will be further reviewed and discussed.
Collapse
Affiliation(s)
| | | | | | | | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milano, Italy; (E.F.); (C.P.); (S.V.); (P.O.)
| |
Collapse
|
17
|
Heiney K, Mateus JC, Lopes CDF, Neto E, Lamghari M, Aguiar P. µSpikeHunter: An advanced computational tool for the analysis of neuronal communication and action potential propagation in microfluidic platforms. Sci Rep 2019; 9:5777. [PMID: 30962522 PMCID: PMC6453950 DOI: 10.1038/s41598-019-42148-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 02/26/2019] [Indexed: 12/11/2022] Open
Abstract
Understanding neuronal communication is fundamental in neuroscience, but there are few methodologies offering detailed analysis for well-controlled conditions. By interfacing microElectrode arrays with microFluidics (μEF devices), it is possible to compartmentalize neuronal cultures with a specified alignment of axons and microelectrodes. This setup allows the extracellular recording of spike propagation with a high signal-to-noise ratio over the course of several weeks. Addressing these μEF devices, we developed an advanced yet easy-to-use publically available computational tool, μSpikeHunter, which provides a detailed quantification of several communication-related properties such as propagation velocity, conduction failure, spike timings, and coding mechanisms. The combination of μEF devices and μSpikeHunter can be used in the context of standard neuronal cultures or with co-culture configurations where, for example, communication between sensory neurons and other cell types is monitored and assessed. The ability to analyze axonal signals (in a user-friendly, time-efficient, high-throughput manner) opens the door to new approaches in studies of peripheral innervation, neural coding, and neuroregeneration, among many others. We demonstrate the use of μSpikeHunter in dorsal root ganglion neurons where we analyze the presence of both anterograde and retrograde signals in μEF devices. A fully functional version of µSpikeHunter is publically available for download from https://github.com/uSpikeHunter .
Collapse
Affiliation(s)
- Kristine Heiney
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.,INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal
| | - José C Mateus
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.,INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.,ICBAS - Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Rua Jorge de Viterbo Ferreira, 4050-313, Porto, Portugal
| | - Cátia D F Lopes
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.,INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal
| | - Estrela Neto
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.,INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal
| | - Meriem Lamghari
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.,INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal
| | - Paulo Aguiar
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal. .,INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal.
| |
Collapse
|
18
|
George DS, Anderson WA, Sommerhage F, Willenberg AR, Hines RB, Bosak AJ, Willenberg BJ, Lambert S. Bundling of axons through a capillary alginate gel enhances the detection of axonal action potentials using microelectrode arrays. J Tissue Eng Regen Med 2019; 13:385-395. [PMID: 30636354 DOI: 10.1002/term.2793] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 10/25/2018] [Accepted: 12/17/2018] [Indexed: 11/09/2022]
Abstract
Microelectrode arrays (MEAs) have become important tools in high throughput assessment of neuronal activity. However, geometric and electrical constraints largely limit their ability to detect action potentials to the neuronal soma. Enhancing the resolution of these systems to detect axonal action potentials has proved both challenging and complex. In this study, we have bundled sensory axons from dorsal root ganglia through a capillary alginate gel (Capgel™) interfaced with an MEA and observed an enhanced ability to detect spontaneous axonal activity compared with two-dimensional cultures. Moreover, this arrangement facilitated the long-term monitoring of spontaneous activity from the same bundle of axons at a single electrode. Finally, using waveform analysis for cultures treated with the nociceptor agonist capsaicin, we were able to dissect action potentials from multiple axons on an individual electrode, suggesting that this model can reproduce the functional complexity associated with sensory fascicles in vivo. This novel three-dimensional functional model of the peripheral nerve can be used to study the functional complexities of peripheral neuropathies and nerve regeneration as well as being utilized in the development of novel therapeutics.
Collapse
Affiliation(s)
- Dale S George
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, FL, USA
| | - Wesley A Anderson
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, FL, USA
| | - Frank Sommerhage
- NanoScience Technology Center, University of Central Florida, Orlando, FL, USA
| | - Alicia R Willenberg
- Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, FL, USA
| | - Robert B Hines
- Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, FL, USA
| | - Alexander J Bosak
- Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, FL, USA
| | - Bradley J Willenberg
- Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, FL, USA.,Saisijin Biotech LLC, St. Cloud, FL, USA
| | - Stephen Lambert
- Department of Medical Education, College of Medicine, University of Central Florida, Orlando, FL, USA
| |
Collapse
|
19
|
Forró C, Thompson-Steckel G, Weaver S, Weydert S, Ihle S, Dermutz H, Aebersold MJ, Pilz R, Demkó L, Vörös J. Modular microstructure design to build neuronal networks of defined functional connectivity. Biosens Bioelectron 2018; 122:75-87. [DOI: 10.1016/j.bios.2018.08.075] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 08/27/2018] [Accepted: 08/30/2018] [Indexed: 02/01/2023]
|
20
|
Moutaux E, Charlot B, Genoux A, Saudou F, Cazorla M. An integrated microfluidic/microelectrode array for the study of activity-dependent intracellular dynamics in neuronal networks. LAB ON A CHIP 2018; 18:3425-3435. [PMID: 30289147 DOI: 10.1039/c8lc00694f] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In the central nervous system, neurons are organized in specific neural networks with distinct electrical patterns, input integration capacities, and intracellular dynamics. In order to better understand how neurons process information, it is crucial to keep the complex organization of brain circuits. However, performing subcellular investigations with high spatial and temporal resolution in vivo is technically challenging, especially in fine structures, such as axonal projections. Here, we present an on-a-chip system that combines a microfluidic platform with a dedicated matrix of electrodes to study activity-dependent dynamics in the physiological context of brain circuits. Because this system is compatible with high-resolution video-microscopy, it is possible to simultaneously record intracellular dynamics and electrical activity in presynaptic axonal projections and in their postsynaptic neuronal targets. Similarly, specific patterns of electrical activity can be applied to both compartments in order to investigate how intrinsic and network activities influence intracellular dynamics. The fluidic isolation of each compartment further allows the selective application of drugs at identified sites to study activity-dependent synaptic transmission. This integrated microfluidic/microelectrode array (microMEA) platform is a valuable tool for studying various intracellular and synaptic dynamics in response to neuronal activity in a physiologically relevant context that resembles in vivo brain circuits.
Collapse
Affiliation(s)
- Eve Moutaux
- Grenoble Institut des Neurosciences, Univ. Grenoble Alpes, INSERM U1216, Bat. Edmond J. Safra, Chemin F Ferrini, F-38000 Grenoble, France.
| | | | | | | | | |
Collapse
|
21
|
Joo S, Nam Y. Slow-Wave Recordings From Micro-Sized Neural Clusters Using Multiwell Type Microelectrode Arrays. IEEE Trans Biomed Eng 2018; 66:403-410. [PMID: 29993399 DOI: 10.1109/tbme.2018.2843793] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The use of microelectrode array (MEA) recordings is a very effective neurophysiological method because it is able to continuously and noninvasively obtain the spatiotemporal information of electrical activity from many neurons constituting a neural network. Very recently, studies have been published that used MEAs for the measurement of a low-frequency component of electrical activity as an indicator of diverse activity of cultured neurons. The occurrence of low-frequency activities has electrophysiological information that does not include the information from fast spikes. However, there is no in vitro experimental model suitable for measuring the low-frequency activities (slow-waves) for further study. METHODS Neural clusters consisting of dozens of neurons were placed directly onto each electrode of an MEA from which fast spikes and slow-waves were measured. RESULTS We obtained sufficient data on the early development patterns of the slow-waves and the spikes measured from many independent neural clusters confirming that the slow-waves occurred first before the emergence of the spikes in the neural clusters. We also showed that changes in the occurrence frequency of the slow-waves for synaptic blockers were measured from a large number of independent cultures. CONCLUSION Microsized neural cluster arrays, which can be combined with conventional MEAs, are suitable for multiple simultaneous recordings of slow-waves. SIGNIFICANCE Our technology provides a simple but useful method to study the generation of a low-frequency component of the electrical activity in cultured neural networks that are not yet well known as well as to expand the use of conventional MEAs.
Collapse
|
22
|
Sakai K, Shimba K, Kotani K, Jimbo Y. A co-culture microtunnel technique demonstrating a significant contribution of unmyelinated Schwann cells to the acceleration of axonal conduction in Schwann cell-regulated peripheral nerve development. Integr Biol (Camb) 2018; 9:678-686. [PMID: 28581556 DOI: 10.1039/c7ib00051k] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Schwann cells (SCs) contribute to the regulation of axonal conduction in a myelin-dependent and -independent manner. However, due to the lack of investigative techniques that are able to record axonal conduction under conditions that control the proliferation of specific SC types, little is known about the extent to which myelinated SCs (mSCs) and unmyelinated SCs (umSCs) modulate axonal conduction. In this study, a microtunnel-electrode approach was applied to a neuron/SC co-culture technique. Rat dorsal root ganglion neurons and SCs were co-cultured in a microtunnel-electrode device, which enabled recording of the conduction delay in multiple axons passing through microtunnels. Despite the absence of nuclei in the microtunnel when SCs were eliminated, cultured cells were densely packed and expressed S100 beta (an SC marker) at a rate of 96% in neuron/SC co-culture, indicating that SCs migrated into the microtunnel. In addition, supplementation with ascorbic acid after 6 days in vitro (DIV) successfully induced myelination from 22 DIV. Activity recording experiments indicated that the conduction delay decreased with culture length from 17 DIV in the neuron/SC co-culture but not in neuron monoculture. Interestingly, the SC-modulated shortening of conduction delay was attenuated at 17 DIV and 22 DIV by supplementing the culture medium with ascorbic acid and, at the same time, suppressing SC proliferation, suggesting that immature umSCs increased axonal conduction velocity in a cell density-dependent manner before the onset of myelination. These results suggest that this method is an effective tool for investigating the contributions of mSCs or umSCs to the regulation of axonal conduction.
Collapse
Affiliation(s)
- Koji Sakai
- School of Engineering, The University of Tokyo, Room 1122, Faculty of Engineering Building 14, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | | | | | | |
Collapse
|
23
|
Design of Cultured Neuron Networks in vitro with Predefined Connectivity Using Asymmetric Microfluidic Channels. Sci Rep 2017; 7:15625. [PMID: 29142321 PMCID: PMC5688062 DOI: 10.1038/s41598-017-15506-2] [Citation(s) in RCA: 77] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 10/26/2017] [Indexed: 11/16/2022] Open
Abstract
The architecture of neuron connectivity in brain networks is one of the basic mechanisms by which to organize and sustain a particular function of the brain circuitry. There are areas of the brain composed of well-organized layers of neurons connected by unidirectional synaptic connections (e.g., cortex, hippocampus). Re-engineering of the neural circuits with such a heterogeneous network structure in culture may uncover basic mechanisms of emergent information functions of these circuits. In this study, we present such a model designed with two subpopulations of primary hippocampal neurons (E18) with directed connectivity grown in a microfluidic device with asymmetric channels. We analysed and compared neurite growth in the microchannels with various shapes that promoted growth dominantly in one direction. We found an optimal geometric shape features of the microchannels in which the axons coupled two chambers with the neurons. The axons grew in the promoted direction and formed predefined connections during the first 6 days in vitro (DIV). The microfluidic devices were coupled with microelectrode arrays (MEAs) to confirm unidirectional spiking pattern propagation through the microchannels between two compartments. We found that, during culture development, the defined morphological and functional connectivity formed and was maintained for up to 25 DIV.
Collapse
|
24
|
Toivanen M, Pelkonen A, Mäkinen M, Ylä-Outinen L, Sukki L, Kallio P, Ristola M, Narkilahti S. Optimised PDMS Tunnel Devices on MEAs Increase the Probability of Detecting Electrical Activity from Human Stem Cell-Derived Neuronal Networks. Front Neurosci 2017; 11:606. [PMID: 29163011 PMCID: PMC5671636 DOI: 10.3389/fnins.2017.00606] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Accepted: 10/17/2017] [Indexed: 12/22/2022] Open
Abstract
Measurement of the activity of human pluripotent stem cell (hPSC)-derived neuronal networks with microelectrode arrays (MEAs) plays an important role in functional in vitro brain modelling and in neurotoxicological screening. The previously reported hPSC-derived neuronal networks do not, however, exhibit repeatable, stable functional network characteristics similar to rodent cortical cultures, making the interpretation of results difficult. In earlier studies, microtunnels have been used both to control and guide cell growth and amplify the axonal signals of rodent neurons. The aim of the current study was to develop tunnel devices that would facilitate signalling and/or signal detection in entire hPSC-derived neuronal networks containing not only axons, but also somata and dendrites. Therefore, MEA-compatible polydimethylsiloxane (PDMS) tunnel devices with 8 different dimensions were created. The hPSC-derived neurons were cultured in the tunnel devices on MEAs, and the spontaneous electrical activity of the networks was measured for 5 weeks. Although the tunnel devices improved the signal-to-noise ratio only by 1.3-fold at best, they significantly increased the percentage of electrodes detecting neuronal activity (52–100%) compared with the controls (27%). Significantly higher spike and burst counts were also obtained using the tunnel devices. Neuronal networks inside the tunnels were amenable to pharmacological manipulation. The results suggest that tunnel devices encompassing the entire neuronal network can increase the measured spontaneous activity in hPSC-derived neuronal networks on MEAs. Therefore, they can increase the efficiency of functional studies of hPSC-derived networks on MEAs.
Collapse
Affiliation(s)
- Maria Toivanen
- NeuroGroup, BioMediTech Institute and Faculty of Medicine and Biosciences, University of Tampere, Tampere, Finland
| | - Anssi Pelkonen
- NeuroGroup, BioMediTech Institute and Faculty of Medicine and Biosciences, University of Tampere, Tampere, Finland
| | - Meeri Mäkinen
- NeuroGroup, BioMediTech Institute and Faculty of Medicine and Biosciences, University of Tampere, Tampere, Finland
| | - Laura Ylä-Outinen
- NeuroGroup, BioMediTech Institute and Faculty of Medicine and Biosciences, University of Tampere, Tampere, Finland
| | - Lassi Sukki
- Micro and Nanosystems Research Group, BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Pasi Kallio
- Micro and Nanosystems Research Group, BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Mervi Ristola
- NeuroGroup, BioMediTech Institute and Faculty of Medicine and Biosciences, University of Tampere, Tampere, Finland
| | - Susanna Narkilahti
- NeuroGroup, BioMediTech Institute and Faculty of Medicine and Biosciences, University of Tampere, Tampere, Finland
| |
Collapse
|