1
|
Xu W, Cao Y, Shi H, Jia X, Zheng Y, Tan Z, Zhao R, Wu H. Skin-interfaced sweat monitoring patch constructed by flexible microfluidic capillary pump and Cu-MOF sensitized electrochemical sensor. Talanta 2025; 291:127895. [PMID: 40056654 DOI: 10.1016/j.talanta.2025.127895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Revised: 02/21/2025] [Accepted: 03/03/2025] [Indexed: 03/10/2025]
Abstract
The limitations of skin-interfaced sweat monitoring are mainly reflected in the effective collection of sweat and the high sensitivity of the detection. This work proposes a new type of sweat monitoring patch based on a flexible microfluidic chip fabricated by a capillary pump and a copper-based metal-based organic framework (Cu-MOF) sensitized electrochemical sensor. The sweat in the microchannel is driven by a capillary pump to ensure the smooth collection and transportation. The sweat collection channel adopts the ingenious design of wedge-shaped structure, which helps to spontaneously generate Laplacian forces to direct sweat to the detection area. The detection area combines upper and lower capillary pumps, which aim to improve the efficiency of sweat collection. The controllable preparation of Cu-MOF was realized by using a micro-mixer, and the glucose sensor was prepared with it as the probe. The Cu-MOF/PANI layered electrode was prepared, which effectively improved the sensitivity of glucose detection and achieved a significant detection limit of 2.84 μM in the concentration range of 0-1 mM. Sodium and potassium selective electrode were also integrated into a unified screen-printed electrode, and a portable electrochemical detection module, a Bluetooth transmission module, and a mobile phone receiving application were developed. The sweat monitoring patch shows potential in applications such as sports performance monitoring, healthcare, and personalized medicine, opening new avenues for non-invasive health monitoring and early disease detection.
Collapse
Affiliation(s)
- Weizheng Xu
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Yu Cao
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Huanhuan Shi
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China.
| | - Xuanhao Jia
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Yun Zheng
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Zhongjian Tan
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Rui Zhao
- Department of Clinical Laboratory, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, 330052, People's Republic of China
| | - Hongwen Wu
- Jiangxi Provincial Key Laboratory of Prevention and Treatment of Infectious Diseases, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, 330052, People's Republic of China.
| |
Collapse
|
2
|
Kharkova A, Kuznetsova L, Perchikov R, Gertsen M, Melnikov P, Zaitsev N, Zhang J, Arlyapov V. Bionanocomposite Four-Channel Biosensor for Rapid and Convenient Monitoring of Glucose, Lactate, Ethanol and Starch. Gels 2025; 11:355. [PMID: 40422375 DOI: 10.3390/gels11050355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2025] [Revised: 05/02/2025] [Accepted: 05/06/2025] [Indexed: 05/28/2025] Open
Abstract
A biosensor for the determination of glucose, lactate, ethanol and starch in beverages has been developed using enzymes immobilized by a redox-active gel on a screen-printed electrode. A significant improvement proposed for multichannel biosensors, overcoming stability and sensitivity issues by covalently binding phenazine mediators to a biocompatible protein hydrogel, enhancing the packaging of the enzyme. Glucose oxidase (GOx), alcohol oxidase (AOx) and lactate oxidase (LOx) were used as biological materials, as well as a mixture of GOx with γ-amylase (Am). Redox gels were synthesized from bovine serum albumin (BSA) and phenazine derivatives. It was shown that a neutral red-based redox gel combined with single-walled carbon nanotubes is more promising than other substrates for enzyme immobilization. The lower limit of quantification for glucose, ethanol, lactate and starch using these systems is 0.035 mM, 2.3 mM, 15 mM and 2 mg/L, respectively. Biosensors were used to analyze the content of these substances in alcoholic, kvass and fermentation mass. Statistical analysis of the results showed that the values of glucose, ethanol, lactic acid and starch determined using biosensors and obtained by reference methods differ insignificantly. A set of biosensors developed on the basis of specifically selected enzymes is effective for controlling biotechnological processes and can be used as an alternative to classical analytical methods.
Collapse
Affiliation(s)
- Anna Kharkova
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia
| | - Lyubov Kuznetsova
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia
| | - Roman Perchikov
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia
| | - Maria Gertsen
- Laboratory of Soil Chemistry and Ecology, Tula State Lev Tolstoy Pedagogical University, 300026 Tula, Russia
| | - Pavel Melnikov
- M.V. Lomonosov Institute of Fine Chemical Technologies, MIREA-Russian Technological University, 119571 Moscow, Russia
| | - Nikolay Zaitsev
- Econics-Expert Ltd., Akademika Bakuleva St., 6, 117513 Moscow, Russia
| | - Jun Zhang
- National Key Laboratory of Urban and Rural Water Resources and Water Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Vyacheslav Arlyapov
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia
| |
Collapse
|
3
|
Wang M, Zheng J, Zhang G, Lu S, Zhou J. Wearable Electrochemical Glucose Sensors for Fluid Monitoring: Advances and Challenges in Non-Invasive and Minimally Invasive Technologies. BIOSENSORS 2025; 15:309. [PMID: 40422047 DOI: 10.3390/bios15050309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2025] [Revised: 05/02/2025] [Accepted: 05/06/2025] [Indexed: 05/28/2025]
Abstract
This review highlights the latest developments in wearable electrochemical glucose sensors, focusing on their transition from invasive to non-invasive and minimally invasive designs. We discuss the underlying mechanisms, performance metrics, and practical challenges of these technologies, emphasizing their potential to revolutionize diabetes care. Additionally, we explore the motivation behind this review: to provide a comprehensive analysis of emerging sensing platforms, assess their clinical applicability, and identify key research gaps that need addressing to achieve reliable, long-term glucose monitoring. By evaluating electrochemical sensors based on tears, saliva, sweat, urine, and interstitial fluid, this work aims to guide future innovations toward more accessible, accurate, and user-friendly solutions for diabetic patients, ultimately improving their quality of life and disease management outcomes.
Collapse
Affiliation(s)
- Ming Wang
- School of Chemical and Printing-Dyeing Engineering, Henan University of Engineering, Zhengzhou 450007, China
| | - Junjie Zheng
- College of Intelligent Textile and Fabric Electronics, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Ge Zhang
- College of Intelligent Textile and Fabric Electronics, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Shiyan Lu
- College of Intelligent Textile and Fabric Electronics, Zhongyuan University of Technology, Zhengzhou 450007, China
| | - Jinli Zhou
- College of Intelligent Textile and Fabric Electronics, Zhongyuan University of Technology, Zhengzhou 450007, China
| |
Collapse
|
4
|
Rabiee N. Revolutionizing biosensing with wearable microneedle patches: innovations and applications. J Mater Chem B 2025; 13:5264-5289. [PMID: 40264330 DOI: 10.1039/d5tb00251f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/24/2025]
Abstract
Wearable microneedle (MN) patches have emerged as a transformative platform for biosensing, offering a minimally invasive and user-friendly approach to real-time health monitoring and disease diagnosis. Primarily designed to access interstitial fluid (ISF) through shallow skin penetration, MNs enable precise and continuous sampling of biomarkers such as glucose, lactate, and electrolytes. Additionally, recent innovations have integrated MN arrays with microfluidic and porous structures to support sweat-based analysis, where MNs act as structural or functional components in hybrid wearable systems. This review explores the design, fabrication, and functional integration of MNs into wearable devices, highlighting advances in multi-analyte detection, wireless data transmission, and self-powered sensing. Challenges related to material biocompatibility, sensor stability, scalability, and user variability are addressed, alongside emerging opportunities in microfluidics, artificial intelligence, and soft materials. Overall, MN-based biosensing platforms are poised to redefine personalized healthcare by enabling dynamic, decentralized, and accessible health monitoring.
Collapse
Affiliation(s)
- Navid Rabiee
- Department of Basic Medical Science, School of Medicine, Tsinghua University, Beijing, 100084, China.
- Tsinghua-Peking Joint Center for Life Sciences, Tsinghua University, Beijing, 100084, China
- MOE Key Laboratory of Bioinformatics, Tsinghua University, Beijing, 100084, China
- Department of Biomaterials, Saveetha Dental College and Hospitals, SIMATS, Saveetha University, Chennai 600077, India
| |
Collapse
|
5
|
Lou G, Miao Z, Hassan M, Celebi K. Colorimetric Detection of Potassium Ions by Electrochromic Thin Film Devices. SMALL METHODS 2025:e2500439. [PMID: 40326957 DOI: 10.1002/smtd.202500439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2025] [Revised: 04/14/2025] [Indexed: 05/07/2025]
Abstract
Potassium ion (K+) detection technology based on electrochemical sensing has proven to be feasible and widely used in physiological real-time monitoring and pathological prediction. Nevertheless, chip integration, wireless communication needs, and specific detection limits present challenges. In this study, high-performance electrochromic materials (W18O49 nanowires) and ion-selective thin films are introduced to present a highly selective, colorimetric K+ biosensor, which demonstrates excellent selectivity in complex ionic environments. The thin film electrochromic electrode offers both colorimetric and electrochemical K+ detection simultaneously from 1 mm to 1000 mm concentration range, achieving up to ≈48% optical transmittance modulation, with a coloration time of 15 s. At the clinically relevant K+ concentration range of 1-10 mm, the electrode displays a linear transmittance modulation sensitivity of ≈0.6% per mm concentration change. Stability tests demonstrate that the colorimetric detection maintains 96% of its efficiency after 100 full concentration change cycles. A compact solid-state sensing device incorporating the electrochromic thin films has also been fabricated, and optically quantified K+ concentration in real-life sweat samples.
Collapse
Affiliation(s)
- Gang Lou
- ZJU-UIUC Institute, Zhejiang University, Haining, Zhejiang, 314400, China
- School of Materials Science and Engineering, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Ziang Miao
- ZJU-UIUC Institute, Zhejiang University, Haining, Zhejiang, 314400, China
- College of Energy Engineering Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Muhammad Hassan
- Oxford Suzhou Centre for Advanced Research (OSCAR), University of Oxford, Suzhou, 215123, China
| | - Kemal Celebi
- ZJU-UIUC Institute, Zhejiang University, Haining, Zhejiang, 314400, China
- The Grainger College of Engineering, Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| |
Collapse
|
6
|
Coskun A, Savas IN, Can O, Lippi G. From population-based to personalized laboratory medicine: continuous monitoring of individual laboratory data with wearable biosensors. Crit Rev Clin Lab Sci 2025; 62:198-227. [PMID: 39893518 DOI: 10.1080/10408363.2025.2453152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2024] [Revised: 09/28/2024] [Accepted: 01/09/2025] [Indexed: 02/04/2025]
Abstract
Monitoring individuals' laboratory data is essential for assessing their health status, evaluating the effectiveness of treatments, predicting disease prognosis and detecting subclinical conditions. Currently, monitoring is performed intermittently, measuring serum, plasma, whole blood, urine and occasionally other body fluids at predefined time intervals. The ideal monitoring approach entails continuous measurement of concentration and activity of biomolecules in all body fluids, including solid tissues. This can be achieved through the use of biosensors strategically placed at various locations on the human body where measurements are required for monitoring. High-tech wearable biosensors provide an ideal, noninvasive, and esthetically pleasing solution for monitoring individuals' laboratory data. However, despite significant advances in wearable biosensor technology, the measurement capacities and the number of different analytes that are continuously monitored in patients are not yet at the desired level. In this review, we conducted a literature search and examined: (i) an overview of the background of monitoring for personalized laboratory medicine, (ii) the body fluids and analytes used for monitoring individuals, (iii) the different types of biosensors and methods used for measuring the concentration and activity of biomolecules, and (iv) the statistical algorithms used for personalized data analysis and interpretation in monitoring and evaluation.
Collapse
Affiliation(s)
- Abdurrahman Coskun
- Department of Medical Biochemistry, School of Medicine, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Irem Nur Savas
- Department of Medical Biochemistry, School of Medicine, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Ozge Can
- Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - Giuseppe Lippi
- Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy
| |
Collapse
|
7
|
Li Z, Sun L, Tan Y, Wang Z, Yang X, Huang T, Li J, Zhang Y, Guan B. Flexible Optoelectronic Hybrid Microfiber Long-period Grating Multimodal Sensor. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2025; 12:e2501352. [PMID: 40056056 PMCID: PMC12061331 DOI: 10.1002/advs.202501352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2025] [Revised: 02/23/2025] [Indexed: 05/10/2025]
Abstract
Flexible wearable biosensors have emerged as a promising tool for tracking dynamic glycemic profiles of human body in diabetes management. However, it remains a challenge to balance the shrunken device space and multiple redundant sensing arrays for further advancement in miniaturization of multimodal sensors. Herein, this work proposes an entirely new optoelectronic hybrid multimodal optical fiber sensor which is composed of laser patterning of polydimethylsiloxane (PDMS) to form laser-induced graphene (LIG) as the interdigital electrodes, and a long period grating (LPG) prepared from an optical microfiber encapsulated into the PDMS modulated by periodical structure of LIG electrodes. This operation can simultaneously integrate two heterogeneous sensing mechanisms, optical and electrical, into a single sensor in a compact manner. Combining the LIG electrode with conductive hydrogel, a flexible glucose biosensor based on electrical mechanism is constructed by loading glucose oxidase into the hydrogel. Meanwhile, the microfiber LPG can also be served as a spectroscopically available sensor for biomechanical monitoring. Optical and electrical sensors can work simultaneously but independently of each other, particularly in the scene of wound healing for rat model and movement for human exercise. This platform represents a pivotal step toward multifunctional sensors that enable measurements of biomechanical information and glucose.
Collapse
Affiliation(s)
- Zhenru Li
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Li‐Peng Sun
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Yanzhen Tan
- School of Electronic Engineering and IntelligentizationDongguan University of TechnologyDongguan523808China
| | - Zhiwei Wang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Xiao Yang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Tiansheng Huang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Jie Li
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Yi Zhang
- Key Laboratory of Biomaterials of Guangdong Higher Education InstitutesDepartment of Biomedical EngineeringJinan UniversityGuangzhou510632China
| | - Bai‐Ou Guan
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| |
Collapse
|
8
|
Ghosh S, Neupane R, Sahu DP, Teng J, Kong YL. The continuous actuation of liquid metal with a 3D-printed electrowetting device. MED-X 2025; 3:9. [PMID: 40177535 PMCID: PMC11958460 DOI: 10.1007/s44258-025-00052-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2024] [Revised: 12/29/2024] [Accepted: 01/05/2025] [Indexed: 04/05/2025]
Abstract
The ability of liquid metals (LMs) to recover from repeated stretching and deformation is a particularly attractive attribute for soft bioelectronics. In addition to their high electrical and thermal conductivity, LMs can be actuated, potentially enabling highly durable electro-mechanical and microfluidics systems for applications such as cooling, drug delivery, or reconfigurable electronics. In particular, continuous electrowetting (CEW) phenomena can actuate liquid metal at relatively low voltage and affordable power requirements for wearable systems (~ < 10 V, ~ 10 - 100 µW) by inducing a surface tension gradient across the LM. However, sustaining LM actuation remains challenging due to factors such as electrolyte depletion, polarity changes in multi-electrode systems, and limitations related to LM composition. Here, we demonstrate LM actuation in a circular conduit for prolonged durations of at least nine hours. We enabled sustained actuation by sequentially applying short, direct current (DC) pulses through a multi-electrode system based on the dynamics of LM actuation. As a proof of concept, we also demonstrated the ability of LM to transport electrically conducting, non-conducting, and magnetic materials within a microchannel and show the liquid metal actuation system can be potentially miniaturized to the size of a wearable device. We envision that with further miniaturization of the device architectures, our CEW platform can enable future integration of low-voltage electro-mechanical systems into a broad range of wearable form factors. Graphical Abstract Supplementary Information The online version contains supplementary material available at 10.1007/s44258-025-00052-8.
Collapse
Affiliation(s)
- Samannoy Ghosh
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
| | - Rajan Neupane
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
| | - Dwipak Prasad Sahu
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
| | - Jian Teng
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
| | - Yong Lin Kong
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
| |
Collapse
|
9
|
Song S, Zhou W, Wei X, Zhao H, Hu D, Liu J, Zhang X, Yu S, Yang F. A Janus Fabric with Hexagonal Microcavity Channels for Efficient Urine Transport and Accurate Physiological Monitoring. ACS Sens 2025; 10:2113-2124. [PMID: 39982846 DOI: 10.1021/acssensors.4c03362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2025]
Abstract
The current research on wearable electrochemical sensors for urine monitoring is relatively rare, which is primarily limited by the lack of an active management mechanism to effectively manipulate the transportation of excessive liquids. In this work, a Janus fabric with hexagonal microcavity channels (HMJ-FT) was assembled based on a disposable facial towel, which was further introduced to develop the wearable electrochemical sensor (HMJ-Sensor) for the directional manipulation of urine transportation and simultaneous detection of dopamine (DA) and uric acid (UA). The designed hexagonal microcavity structure can synergistically promote horizontal migration and vertical transport of liquid, thus ensuring efficient and rapid manipulation of urine transportation and preventing its accumulation and reflux, which are essential for accurate, real-time monitoring. Therefore, the constructed HMJ-Sensor demonstrated a lower limit of detection (LOD) compared to most reported wearable sensors, which is 10.0770 nM for DA and 1.4100 nM for UA, respectively. Additionally, it also has the widest detection range known to date (DA: 0.0360-4000 μM; UA: 0.0050-6000 μM), which can better adapt to the large volume of urine transport and significant fluctuations on urine concentration in practical applications. After being subjected to a 120-day storage period along with multiple bending, rubbing, and washing treatments, the HMJ-Sensor maintained its excellent detection performance, indicating its high stability and reliability. This work not only provided a novel strategy for the manipulation of urine transport but also enhanced the detection capabilities of urine monitoring, which holds significant potential for boosting wearable applications and medical monitoring in physiological and clinical settings.
Collapse
Affiliation(s)
- Shijuan Song
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Wenhao Zhou
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Xinyue Wei
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Huijun Zhao
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Dan Hu
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Jiaqing Liu
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Xin Zhang
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| | - Sha Yu
- School of Chemistry and Chemical Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Fengchun Yang
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710127, China
| |
Collapse
|
10
|
Wang Y, Feng X, Chen X. Autonomous Bioelectronic Devices Based on Silk Fibroin. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2025:e2500073. [PMID: 40123251 DOI: 10.1002/adma.202500073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2025] [Revised: 03/01/2025] [Indexed: 03/25/2025]
Abstract
The development of autonomous bioelectronic devices capable of dynamically adapting to changing biological environments represents a significant advancement in healthcare and wearable technologies. Such systems draw inspiration from the precision, adaptability, and self-regulation of biological processes, requiring materials with intrinsic versatility and seamless bio-integration to ensure biocompatibility and functionality over time. Silk fibroin (SF) derived from Bombyx mori cocoons, has emerged as an ideal biomaterial with a unique combination of biocompatibility, mechanical flexibility, and tunable biodegradability. Adding autonomous features into SF, including self-healing, shape-morphing, and controllable degradation, enables dynamic interactions with living tissues while minimizing immune responses and mechanical mismatches. Additionally, structural tunability and environmental sustainability of SF further reinforce its potential as a platform for adaptive implants, epidermal electronics, and intelligent textiles. This review explores recent progress in understanding the structure-property relationships of SF, its modification strategies, and its great potential for integration into advanced autonomous bioelectronic systems while addressing challenges related to scalability, reproducibility, and multifunctionality. Future opportunities, such as AI-assisted material design, scalable fabrication techniques, and the incorporation of wireless and personalized technologies, are also discussed, positioning SF as a key material in bridging the gap between biological systems and artificial technologies.
Collapse
Affiliation(s)
- Yanling Wang
- Institute of Flexible Electronics Technology of THU, Jiaxing, Zhejiang, 314000, China
- Innovative Centre for Flexible Devices (iFLEX), Max Plank-NTU Joint Lab for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Xue Feng
- Institute of Flexible Electronics Technology of THU, Jiaxing, Zhejiang, 314000, China
- Laboratory of Flexible Electronics Technology, Department of Engineering Mechanics, Center for Flexible Electronics Technology, Tsinghua University, Beijing, 100084, China
| | - Xiaodong Chen
- Innovative Centre for Flexible Devices (iFLEX), Max Plank-NTU Joint Lab for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| |
Collapse
|
11
|
Linh VTN, Han S, Koh E, Kim S, Jung HS, Koo J. Advances in wearable electronics for monitoring human organs: Bridging external and internal health assessments. Biomaterials 2025; 314:122865. [PMID: 39357153 DOI: 10.1016/j.biomaterials.2024.122865] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 09/06/2024] [Accepted: 09/26/2024] [Indexed: 10/04/2024]
Abstract
Devices used for diagnosing disease are often large, expensive, and require operation by trained professionals, which can result in delayed diagnosis and missed opportunities for timely treatment. However, wearable devices are being recognized as a new approach to overcoming these difficulties, as they are small, affordable, and easy to use. Recent advancements in wearable technology have made monitoring information possible from the surface of organs like the skin and eyes, enabling accurate diagnosis of the user's internal status. In this review, we categorize the body's organs into external (e.g., eyes, oral cavity, neck, and skin) and internal (e.g., heart, brain, lung, stomach, and bladder) organ systems and introduce recent developments in the materials and designs of wearable electronics, including electrochemical and electrophysiological sensors applied to each organ system. Further, we explore recent innovations in wearable electronics for monitoring of deep internal organs, such as the heart, brain, and nervous system, using ultrasound, electrical impedance tomography, and temporal interference stimulation. The review also addresses the current challenges in wearable technology and explores future directions to enhance the effectiveness and applicability of these devices in medical diagnostics. This paper establishes a framework for correlating the design and functionality of wearable electronics with the physiological characteristics and requirements of various organ systems.
Collapse
Affiliation(s)
- Vo Thi Nhat Linh
- Advanced Bio and Healthcare Materials Research Division, Korea Institute of Materials Science (KIMS), Changwon, 51508, South Korea
| | - Seunghun Han
- School of Biomedical Engineering, College of Health Science, Korea University, Seoul, 02841, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841, South Korea
| | - Eunhye Koh
- Advanced Bio and Healthcare Materials Research Division, Korea Institute of Materials Science (KIMS), Changwon, 51508, South Korea
| | - Sumin Kim
- School of Biomedical Engineering, College of Health Science, Korea University, Seoul, 02841, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841, South Korea
| | - Ho Sang Jung
- Advanced Bio and Healthcare Materials Research Division, Korea Institute of Materials Science (KIMS), Changwon, 51508, South Korea; Advanced Materials Engineering, University of Science and Technology (UST), Daejeon, 34113, South Korea; School of Convergence Science and Technology, Medical Science and Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673, South Korea.
| | - Jahyun Koo
- School of Biomedical Engineering, College of Health Science, Korea University, Seoul, 02841, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841, South Korea.
| |
Collapse
|
12
|
Ding Y, Yang L, Wen J, Ma Y, Dai G, Mo F, Wang J. A Comprehensive Review of Advanced Lactate Biosensor Materials, Methods, and Applications in Modern Healthcare. SENSORS (BASEL, SWITZERLAND) 2025; 25:1045. [PMID: 40006275 PMCID: PMC11858931 DOI: 10.3390/s25041045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2024] [Revised: 01/21/2025] [Accepted: 01/29/2025] [Indexed: 02/27/2025]
Abstract
Lactate is a key metabolite in cellular respiration, and elevated levels usually indicate tissue hypoxia or metabolic dysregulation. The real-time detection of lactate levels is particularly important in situations such as exercise, shock, severe trauma, and tissue injury. Conventional lactate assays are insufficient to address today's complex and variable testing environments, and thus, there is an urgent need for highly sensitive biosensors. This review article provides an overview of the concept and composition of electrochemical lactate biosensors, as well as their recent advances. Comparisons of popular studies on enzymatic and non-enzymatic lactate sensors, the surface-related materials used for modifications to electrochemical lactate biosensors, and the detection methods commonly used for sensors are discussed separately. In addition, advances in implantable and non-implantable miniaturized lactate sensors are discussed, emphasizing their application for continuous real-time monitoring. Despite their potential, challenges such as non-specific binding, biomaterial interference, and biorecognition element stability issues remain during practical applications. Future research should aim to improve sensor design, biocompatibility, and integration with advanced signal processing techniques. With continued innovation, lactate sensors are expected to revolutionize personalized medicine, helping clinicians to increase treatment efficiency and improve the experience of their use.
Collapse
Affiliation(s)
- Yifeng Ding
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
- Department of Anesthesiology, Changhai Hospital, Naval Medical University, Shanghai 200433, China
- Department of Naval Nutrition and Food Hygiene, Faculty of Naval Medicine, Naval Medical University, 800 Xiangyin Road, Shanghai 200433, China
| | - Liuhong Yang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
- Department of Naval Nutrition and Food Hygiene, Faculty of Naval Medicine, Naval Medical University, 800 Xiangyin Road, Shanghai 200433, China
| | - Jing Wen
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
- Department of Anesthesiology, Changhai Hospital, Naval Medical University, Shanghai 200433, China
- Department of Naval Nutrition and Food Hygiene, Faculty of Naval Medicine, Naval Medical University, 800 Xiangyin Road, Shanghai 200433, China
| | - Yuhang Ma
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
- Department of Anesthesiology, Changhai Hospital, Naval Medical University, Shanghai 200433, China
- Department of Naval Nutrition and Food Hygiene, Faculty of Naval Medicine, Naval Medical University, 800 Xiangyin Road, Shanghai 200433, China
| | - Ge Dai
- Department of Naval Nutrition and Food Hygiene, Faculty of Naval Medicine, Naval Medical University, 800 Xiangyin Road, Shanghai 200433, China
- Key Laboratory of Biosafety Defense, Naval Medical University, Ministry of Education, 800 Xiangyin Road, Shanghai 200433, China
| | - Fengfeng Mo
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
- Department of Naval Nutrition and Food Hygiene, Faculty of Naval Medicine, Naval Medical University, 800 Xiangyin Road, Shanghai 200433, China
- Key Laboratory of Biosafety Defense, Naval Medical University, Ministry of Education, 800 Xiangyin Road, Shanghai 200433, China
| | - Jiafeng Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
- Department of Anesthesiology, Changhai Hospital, Naval Medical University, Shanghai 200433, China
| |
Collapse
|
13
|
Yuan Z, Yin H, Zheng M, Chen X, Peng W, Zhou H, Xing J, Wang L, Hu S. Biodegradable, robust, and conductive bacterial cellulose @PPy-P macrofibers as resistive strain sensors for smart textiles. Carbohydr Polym 2025; 349:122963. [PMID: 39638504 DOI: 10.1016/j.carbpol.2024.122963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 10/25/2024] [Accepted: 11/06/2024] [Indexed: 12/07/2024]
Abstract
Fiber-based resistive strain sensors have attracted significant interest in the development of smart wearable devices due to their portability, flexibility, and easy conformability. However, current fiber-based resistive strain sensors mainly composed of metals and nondegradable polymers are not environmentally friendly and have poor mechanical strength. In this work, we examined biodegradable, robust, and conductive macrofibers fabricated through the in situ polymerization of p-toluenesulfonic acid (P-TSA)-doped polypyrrole (PPy) in bacterial cellulose (BC) nanofibers using wet-stretching and wet-twisting methods. The BC/PPy-P macrofibers possessed excellent conductivity (~7.19 S/cm), with superior mechanical properties (~210 MPa tensile strength and 2 GPa Young's modulus). Importantly, the BC/PPy-P microfiber operating as a resistive strain sensor possessed fast response time (15 s) and long-term stability (up to 1000 cycles), which could be used to effectively detect human movements. Moreover, the matrix material BC of BC/PPy-P macrofibers could be completely degraded within 96 h in the cellulase solution, leaving only PPy-P particles that could be recycled for other use. Therefore, the prepared BC/PPy-P microfibers provided a promising strategy for developing green resistive strain sensing fibers, with great potential to design eco-friendly smart fabric for monitoring human movements.
Collapse
Affiliation(s)
- Zaixian Yuan
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Hai Yin
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Min Zheng
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Xiao Chen
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Wei Peng
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Hongfu Zhou
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Jun Xing
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China
| | - Li Wang
- Wuhan Branch of the National Science Library, Chinese Academy of Sciences, Wuhan 430071, China
| | - Sanming Hu
- School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, PR China.
| |
Collapse
|
14
|
Jin J, Ma H, Liang H, Zhang Y. Biopolymer-Derived Carbon Materials for Wearable Electronics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2025:e2414620. [PMID: 39871757 DOI: 10.1002/adma.202414620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2024] [Revised: 12/01/2024] [Indexed: 01/29/2025]
Abstract
Advanced carbon materials are widely utilized in wearable electronics. Nevertheless, the production of carbon materials from fossil-based sources raised concerns regarding their non-renewability, high energy consumption, and the consequent greenhouse gas emissions. Biopolymers, readily available in nature, offer a promising and eco-friendly alternative as a carbon source, enabling the sustainable production of carbon materials for wearable electronics. This review aims to discuss the carbonization mechanisms, carbonization techniques, and processes, as well as the diverse applications of biopolymer-derived carbon materials (BioCMs) in wearable electronics. First, the characteristics of four representative biopolymers, including cellulose, lignin, chitin, and silk fibroin, and their carbonization processes are discussed. Then, typical carbonization techniques, including pyrolysis carbonization, laser-induced carbonization, Joule heating carbonization, hydrothermal transformation, and salt encapsulation carbonization are discussed. The influence of the processes on the morphology and properties of the resultant BioCMs are summarized. Subsequently, applications of BioCMs in wearable devices, including physical sensors, chemical sensors, energy devices, and display devices are discussed. Finally, the challenges currently facing the field and the future opportunities are discussed.
Collapse
Affiliation(s)
- Jiongke Jin
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing, 100084, P. R. China
| | - Haoxuan Ma
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing, 100084, P. R. China
| | - Huarun Liang
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing, 100084, P. R. China
| | - Yingying Zhang
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing, 100084, P. R. China
| |
Collapse
|
15
|
Gou X, Xing Z, Zhang Z, Jin R, Xu Q, Sojic N, Zhu JJ, Ma C. Designable Electrochemiluminescence Patterning for Renewable and Enhanced Bioimaging. Angew Chem Int Ed Engl 2025; 64:e202410825. [PMID: 39536295 DOI: 10.1002/anie.202410825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Revised: 11/11/2024] [Accepted: 11/12/2024] [Indexed: 11/16/2024]
Abstract
Electrochemical imaging enables an in-depth analysis of the interface heterogeneity and reaction kinetics of single entities. However, electrode passivation during electrochemical reactions decreases the active sites and harms the long-term stability. Here, we introduce a method using laser-induced photothermal effects to restore the electrochemical activity, which is particularly displayed as enhanced micrometric patterns in electrochemiluminescence (ECL) microscopy. By co-localization characterization and X-ray photoelectron spectroscopy (XPS), the mechanism of active site regeneration is validated as the removal of the oxide film for restoring the local surface ECL reactivity under laser irradiation. The surface-confined and voltage-dependent features of ECL allows for easy pattern erasure and rewriting, and it shows good reversibility and anti-counterfeiting potential. This approach overcomes the passivation processes, evidently improves the image quality of single biological entities including Shewanella bacteria and cells, and makes the subtle contour structures more distinct. The renewable electrode interface also enhances the ECL signal of model bead-based bioassays. This approach not only showcases precise control in fabricating micron patterns but also holds promise for enhancing the sensitivity in electrochemical immunoassays and bioimaging.
Collapse
Affiliation(s)
- Xiaodan Gou
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, 210023, Nanjing, P. R. China
- University of Bordeaux, Bordeaux INP, ISM, UMR, CNRS 5255, 33607, Pessac, France
| | - Zejing Xing
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, 210023, Nanjing, P. R. China
| | - Zhichen Zhang
- School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, P. R. China
| | - Rong Jin
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, 210023, Nanjing, P. R. China
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, P. R. China
| | - Neso Sojic
- University of Bordeaux, Bordeaux INP, ISM, UMR, CNRS 5255, 33607, Pessac, France
| | - Jun-Jie Zhu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, 210023, Nanjing, P. R. China
| | - Cheng Ma
- School of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, P. R. China
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, 210023, Nanjing, P. R. China
| |
Collapse
|
16
|
Asai M, Isshiki N, Takesue M, Takei K. Calibration-Free and Highly Sensitive Potentiometric Enzyme-Based Biosensors. SMALL METHODS 2025; 9:e2401010. [PMID: 39295464 DOI: 10.1002/smtd.202401010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Revised: 09/04/2024] [Indexed: 09/21/2024]
Abstract
Enzyme-based amperometric biosensors have become popular for healthcare applications. However, they have been under constant pressure for technological innovation to improve their sensitivity and usability. An ideal biosensor has high sensitivity and calibration-free characteristics. This study aims to report enzyme-based glucose and lactate sensors that utilize a proposed "time-derivative of potential (dOCP/dt)" method, with a further aim being to prove theoretically and experimentally that dOCP/dt values are proportional to substrate concentration. High sensitivity is obtained regardless of the electrode size because the electrode potential is independent of the electrode area in the biosensor. Importantly, because the substrate diffusion determines the enzyme reaction rate on the sensors, the dOCP/dt biosensors can essentially eliminate external influences such as temperature and pH. The result is the successful realization of a biosensor that is calibration-free, making it a much more practical option.
Collapse
Affiliation(s)
- Mitsuo Asai
- Performance Chemicals Research, Kao Corporation, Wakayama, 640-8580, Japan
| | - Nobuyuki Isshiki
- Performance Chemicals Research, Kao Corporation, Wakayama, 640-8580, Japan
| | - Masafumi Takesue
- Performance Chemicals Research, Kao Corporation, Wakayama, 640-8580, Japan
| | - Kuniharu Takei
- Graduate School of Information Science and Technology, Hokkaido University, Sapporo, Hokkaido, 060-0814, Japan
| |
Collapse
|
17
|
Zhou S, Cai M, Wang X, Hu W, Fu Z, Gong J, Zhang C, Xu W, Xia L. An integrated textile of electrical signal sensing with visual indicators and energy supply for perspiration management. Biosens Bioelectron 2025; 267:116794. [PMID: 39326321 DOI: 10.1016/j.bios.2024.116794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 08/31/2024] [Accepted: 09/16/2024] [Indexed: 09/28/2024]
Abstract
Recent advances in wearable electronics have enabled the development of sweat sensors providing valuable information for healthcare monitoring. However, the limitations of sweat sensors are excessive dependence on external detection systems, the impossible to real-time visual signal transmission, and inadequate perspiration management. Herein, a single- and double-layer interwoven fabric (SDIF) is designed to achieve indicators of color visualization with an output of electrical signal and energy supply. After absorption of electrolyte, the SDIF can be rapidly activated, connected with the concentration, infiltrated volume, and environmental parameters, and the variational color of SDIF can provide visual indicators. The one tissue cycle of SDIF with three-weft intervals maintains a stable output voltage of ≈1.0 V, conducted by twisting, folding, dynamic bending, and reusing. Moreover, serial tissue cycles can be woven into large fabrics by connecting in series and parallel configurations for energy supply. The developed SDIF with an interweaving structural design using industrial-producible weaving technology provides the functionality of sweat adsorption and transportation, monitoring by recognition of color, and electrical signals to improve perspiration management.
Collapse
Affiliation(s)
- Sijie Zhou
- College of Textiles, Donghua University, Shanghai, 201620, China
| | - Mengyao Cai
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China
| | - Xiaofeng Wang
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China
| | - Wanjin Hu
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China
| | - Zhuan Fu
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China; College of Textile Science and Engineering, Zhejiang Sci-Tech University, Hangzhou, 310018, China
| | - Junyao Gong
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China; School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, 200237, China
| | - Chunhua Zhang
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China
| | - Weilin Xu
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China.
| | - Liangjun Xia
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, China.
| |
Collapse
|
18
|
Shi F, Zhang Z, Ara B, Huang Z, Gui Q, Mansoor A, Sun W. Fe Single-Atom and Fe Cluster-Coupled N, S Co-doped Carbon Nanomaterial-Based Flexible Electrochemical Sweat Biosensor for the Real-Time Analysis of Uric Acid and Tyrosine. ACS Sens 2024; 9:6482-6491. [PMID: 39663677 DOI: 10.1021/acssensors.4c01844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2024]
Abstract
Fe single-atom and Fe cluster-coupled N, S co-doped carbon nanomaterials (FeSA-FeONC-NSC) were prepared through a two-step high-temperature pyrolysis process using Gelidium corneum enriched with C, Fe, O, N, and S as precursors. The analysis by aberration-corrected scanning transmission electron microscopy and X-ray absorption spectroscopy revealed the presence of single-atom Fe in Fe-N4 coordination structures, along with small clusters as Fe-O-coordinated Fe2O3. Single-atom Fe in the form of Fe2+/Fe3+ provides more electrocatalytic active sites, which synergistically accelerates the charge migration process in the assembly of FeSA-FeONC-NSC with Fe2O3 clusters. The flexible nonenzymatic sensor, based on FeSA-FeONC-NSC and fabricated using a polydimethylsiloxane substrate, exhibited excellent catalytic activity for both uric acid (UA) and tyrosine (Tyr). Low detection limits for UA (0.14 μmol L-1) and Tyr (0.03 μmol L-1) were observed by using chronoamperometry in artificial sweat. The in situ detection of sweat was performed in combination with an integrated circuit board affixed to human skin, and the results were generally consistent with those of the high-performance liquid chromatography method. Therefore, FeSA-FeONC-NSC serves as a good modifier for wearable electrochemical sweat sensor applications.
Collapse
Affiliation(s)
- Fan Shi
- Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158, China
- College of Resources and Environment, Baoshan University, Baoshan 678000, China
| | - Zejun Zhang
- Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158, China
- College of Chemistry and Chemical Engineering, Zhaotong University, Zhaotong 657000, China
| | - Behisht Ara
- Institute of Chemical Sciences, University of Peshawar, Peshawar 25120, Pakistan
| | - Zhitan Huang
- Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158, China
| | - Qifeng Gui
- College of Resources and Environment, Baoshan University, Baoshan 678000, China
| | - Ahmad Mansoor
- Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158, China
| | - Wei Sun
- Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou 571158, China
| |
Collapse
|
19
|
Feng G, Wang Y, Liu D, Cheng Z, Feng Q, Wang H, Han W, Jia C. Development and Applications in Intelligent Sports of Hydrogel-Based Triboelectric Nanogenerators. MATERIALS (BASEL, SWITZERLAND) 2024; 18:33. [PMID: 39795679 PMCID: PMC11721276 DOI: 10.3390/ma18010033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2024] [Revised: 12/11/2024] [Accepted: 12/18/2024] [Indexed: 01/13/2025]
Abstract
As an emerging self-powered technology, triboelectric nanogenerators have the characteristics of a simple structure, high conversion efficiency, diverse material selection, and stable output. Hydrogels have the advantages of flexibility, extensibility, and shape adaptability, which means that hydrogel-based triboelectric nanogenerators (H-TENGs) have high flexibility, self-healing abilities, conductivity, and fatigue resistance. They can still operate normally in scenarios involving bending, pressing, stretching, and folding. H-TENGs offer a method of versatile and sustainable innovation in sports monitoring. This review elucidates the working principles and modes of H-TENGs, examines H-TENG characteristics that are relevant to intelligent sports, and summarizes their applications in this field. This paper concludes with a discussion on the development and applications of H-TENGs in intelligent sports.
Collapse
Affiliation(s)
- Guishan Feng
- School of Competitive Sports, Shandong Sport University, Rizhao 276826, China; (G.F.); (H.W.)
| | - Yunlu Wang
- Physical Education Department, Northeastern University, Shenyang 110819, China; (Y.W.); (D.L.); (Z.C.); (Q.F.)
| | - Dongsheng Liu
- Physical Education Department, Northeastern University, Shenyang 110819, China; (Y.W.); (D.L.); (Z.C.); (Q.F.)
| | - Zihang Cheng
- Physical Education Department, Northeastern University, Shenyang 110819, China; (Y.W.); (D.L.); (Z.C.); (Q.F.)
| | - Qingyang Feng
- Physical Education Department, Northeastern University, Shenyang 110819, China; (Y.W.); (D.L.); (Z.C.); (Q.F.)
| | - Hongwei Wang
- School of Competitive Sports, Shandong Sport University, Rizhao 276826, China; (G.F.); (H.W.)
| | - Wei Han
- School of Competitive Sports, Shandong Sport University, Rizhao 276826, China; (G.F.); (H.W.)
| | - Changjun Jia
- Department of Public Teaching, Qilu Medical University, Zibo 255300, China
| |
Collapse
|
20
|
Guo X, Zhang Q, Zhang C, Mi M, Li X, Zhang X, Ramakrishna S, Ji D, Qin X. Pumpless microfluidic sweat sensing yarn. Biosens Bioelectron 2024; 266:116713. [PMID: 39232436 DOI: 10.1016/j.bios.2024.116713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 08/13/2024] [Accepted: 08/26/2024] [Indexed: 09/06/2024]
Abstract
Textile sweat sensors possess immense potential for non-invasive health monitoring. Rapid in-situ sweat capture and prevention of its evaporation are crucial for accurate and stable real-time monitoring. Herein, we introduce a unidirectional, pump-free microfluidic sweat management system to tackle this challenge. A nanofiber sheath layer on micrometer-scale sensing filaments enables this pumpless microfluidic design. Utilizing the capillary effect of the nanofibers allows for the swift capture of sweat, while the differential configuration of the hydrophilic and hydrophobic properties of the sheath and core yarns prevents sweat evaporation. The Laplace pressure difference between the cross-scale fibers facilitates the management system to ultimately expulse sweat. This results in microfluidic control of sweat without the need for external forces, resulting in rapid (<5 s), sensitive (19.8 nA μM-1), and stable (with signal noise and drift suppression) sweat detection. This yarn sensor can be easily integrated into various fabrics, enabling the creation of health monitoring smart garments. The garments maintain good monitoring performance even after 20 washes. This work provides a solution for designing smart yarns for high-precision, stable, and non-invasive health monitoring.
Collapse
Affiliation(s)
- Xinyue Guo
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Qiangqiang Zhang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Chentian Zhang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Mingyue Mi
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Xinxin Li
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Xueping Zhang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Seeram Ramakrishna
- Department of Mechanical Engineering, National University of Singapore, 117574, Singapore
| | - Dongxiao Ji
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China.
| | - Xiaohong Qin
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China.
| |
Collapse
|
21
|
Massaglia G, Spisni G, Serra T, Quaglio M. Laser-Induced Graphene Electrodes for Flexible pH Sensors. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:2008. [PMID: 39728544 PMCID: PMC11728752 DOI: 10.3390/nano14242008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 11/26/2024] [Accepted: 12/09/2024] [Indexed: 12/28/2024]
Abstract
In the growing field of personalized medicine, non-invasive wearable devices and sensors are valuable diagnostic tools for the real-time monitoring of physiological and biokinetic signals. Among all the possible multiple (bio)-entities, pH is important in defining health-related biological information, since its variations or alterations can be considered the cause or the effect of disease and disfunction within a biological system. In this work, an innovative (bio)-electrochemical flexible pH sensor was proposed by realizing three electrodes (working, reference, and counter) directly on a polyimide (Kapton) sheet through the implementation of CO2 laser writing, which locally converts the polymeric sheet into a laser-induced graphene material (LIG electrodes), preserving inherent mechanical flexibility of Kapton. A uniform distribution of nanostructured PEDOT:PSS was deposited via ultrasonic spray coating onto an LIG working electrode as the active material for pH sensing. With a pH-sensitive PEDOT coating, this flexible sensor showed good sensitivity defined through a linear Nernstian slope of (75.6 ± 9.1) mV/pH, across a pH range from 1 to 7. We demonstrated the capability to use this flexible pH sensor during dynamic experiments, and thus concluded that this device was suitable to guarantee an immediate response and good repeatability by measuring the same OCP values in correspondence with the same pH applied.
Collapse
Affiliation(s)
- Giulia Massaglia
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
- Center for Sustainable Future Technologies, Istituto Italiano di Tecnologia, CSFT@Polito, Via Livorno 60, 10100 Turin, Italy
| | - Giacomo Spisni
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
- Center for Sustainable Future Technologies, Istituto Italiano di Tecnologia, CSFT@Polito, Via Livorno 60, 10100 Turin, Italy
| | - Tommaso Serra
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
| | - Marzia Quaglio
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
| |
Collapse
|
22
|
Wu X, Ma X, Liu Z, Yu X, Yu H. Porous Core-Shell Yarn in Wearable Electrochemical Sensors for Real-Time Sweat Monitoring. ACS APPLIED MATERIALS & INTERFACES 2024. [PMID: 39561002 DOI: 10.1021/acsami.4c15353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2024]
Abstract
Wearable sweat sensors have garnered substantial attention owing to their actual significance in the noninvasive and real-time monitoring of health conditions. However, it remains significantly challenging to efficiently construct a high-sensitivity sweat sensor with stable long-term sensing capability. Herein, we report an effective methodology based on wet-spinning/acid-etching technology to construct a porous core-shell yarn-based wearable electrochemical sensor. This strategy increases the inductive surface area of the ion concentration and facilitates signal transmission. As a result, the sensor demonstrates high sensitivity for monitoring K+ and pH in sweat (54.89 mV/dec for K+ and 40.2 mV/pH for pH). Furthermore, the sensors exhibit outstanding sensing stability, good long-term stability (>16 h), and satisfactory bending resistance (>1000 cycles). More importantly, the sensing yarns could be prepared at speeds of up to 500 m/h with a continuous preparation strategy, which enabled mass fabrication of the electrochemical sensor. Electrochemical sensors could serve as sweat-sensing systems for real-time health monitoring and hold great potential for the commercialization of health-detection technology.
Collapse
Affiliation(s)
- Xueqi Wu
- Guangdong-Hong Kong Joint Laboratory for New Textile Materials, School of Textile Science and Engineering, Wuyi University, Jiangmen 529020, China
| | - Xiangda Ma
- Guangdong-Hong Kong Joint Laboratory for New Textile Materials, School of Textile Science and Engineering, Wuyi University, Jiangmen 529020, China
| | - Zijin Liu
- Guangdong-Hong Kong Joint Laboratory for New Textile Materials, School of Textile Science and Engineering, Wuyi University, Jiangmen 529020, China
| | - Xi Yu
- Guangdong-Hong Kong Joint Laboratory for New Textile Materials, School of Textile Science and Engineering, Wuyi University, Jiangmen 529020, China
- Guangdong Laboratory of Chemistry and Fine Chemical Industry Jieyang Center, Jieyang 515200, China
| | - Hui Yu
- Guangdong-Hong Kong Joint Laboratory for New Textile Materials, School of Textile Science and Engineering, Wuyi University, Jiangmen 529020, China
- Guangdong Laboratory of Chemistry and Fine Chemical Industry Jieyang Center, Jieyang 515200, China
| |
Collapse
|
23
|
Vo DK, Trinh KTL. Advances in Wearable Biosensors for Healthcare: Current Trends, Applications, and Future Perspectives. BIOSENSORS 2024; 14:560. [PMID: 39590019 PMCID: PMC11592256 DOI: 10.3390/bios14110560] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2024] [Revised: 11/15/2024] [Accepted: 11/16/2024] [Indexed: 11/28/2024]
Abstract
Wearable biosensors are a fast-evolving topic at the intersection of healthcare, technology, and personalized medicine. These sensors, which are frequently integrated into clothes and accessories or directly applied to the skin, provide continuous, real-time monitoring of physiological and biochemical parameters such as heart rate, glucose levels, and hydration status. Recent breakthroughs in downsizing, materials science, and wireless communication have greatly improved the functionality, comfort, and accessibility of wearable biosensors. This review examines the present status of wearable biosensor technology, with an emphasis on advances in sensor design, fabrication techniques, and data analysis algorithms. We analyze diverse applications in clinical diagnostics, chronic illness management, and fitness tracking, emphasizing their capacity to transform health monitoring and facilitate early disease diagnosis. Additionally, this review seeks to shed light on the future of wearable biosensors in healthcare and wellness by summarizing existing trends and new advancements.
Collapse
Affiliation(s)
- Dang-Khoa Vo
- College of Pharmacy, Gachon University, 191 Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea;
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
24
|
Yang L, Hu Z, Xiang Z, Zhou J, Wang X, Liu Q, Gan L, Shi S, Yang W, Zhang Y, Wu J. A high-entropy electrode material for electrobiochemical and eletrophysiological signals detection. CHEMICAL ENGINEERING JOURNAL 2024; 499:156209. [DOI: 10.1016/j.cej.2024.156209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2024]
|
25
|
Liu Y, Chen L, Li W, Pu J, Wang Z, He B, Yuan S, Xin J, Huang L, Luo Z, Xu J, Zhou X, Zhang H, Zhang Q, Wei L. Scalable Production of Functional Fibers with Nanoscale Features for Smart Textiles. ACS NANO 2024; 18:29394-29420. [PMID: 39428715 DOI: 10.1021/acsnano.4c10111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2024]
Abstract
Functional fibers, retaining nanoscale characteristics or nanomaterial properties, represent a significant advance in nanotechnology. Notably, the combination of scalable manufacturing with cutting-edge nanotechnology further expands their utility across numerous disciplines. Manufacturing kilometer-scale functional fibers with nanoscale properties are critical to the evolution of smart textiles, wearable electronics, and beyond. This review discusses their design principles, manufacturing technologies, and key advancements in the mass production of such fibers. In addition, it summarizes the current applications and state of progress in scalable fiber technologies and provides guidance for future advances in multifunctional smart textiles, by highlighting the upcoming impending demands for evolving nanotechnology. Challenges and directions requiring sustained effort are also discussed, including material selection, device design, large-scale manufacturing, and multifunctional integration. With advances in functional fibers and nanotechnology in large-scale production, wearable electronics, and smart textiles could potentially enhance human-machine interaction and healthcare applications.
Collapse
Affiliation(s)
- Yanting Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Long Chen
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Wulong Li
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Jie Pu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Zhixun Wang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Bing He
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Shixing Yuan
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Jiwu Xin
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Lei Huang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Ziwang Luo
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Jiaming Xu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Xuhui Zhou
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Haozhe Zhang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| | - Qichong Zhang
- Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
| | - Lei Wei
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798
| |
Collapse
|
26
|
Gao N, Xu G, Chang G, Wu Y. From Lab to Life: Self-Powered Sweat Sensors and Their Future in Personal Health Monitoring. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2409178. [PMID: 39467262 DOI: 10.1002/advs.202409178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Revised: 09/27/2024] [Indexed: 10/30/2024]
Abstract
The rapid development of wearable sweat sensors has demonstrated their potential for continuous, non-invasive disease diagnosis and health monitoring. Emerging energy harvesters capable of converting various environmental energy sources-biomechanical, thermal, biochemical, and solar-into electrical energy are revolutionizing power solutions for wearable devices. Based on self-powered technology, the integration of the energy harvesters with wearable sweat sensors can drive the device for biosensing, signal processing, and data transmission. As a result, self-powered sweat sensors are able to operate continuously without external power or charging, greatly facilitating the development of wearable electronics and personalized healthcare. This review focuses on the recent advances in self-powered sweat sensors for personalized healthcare, covering sweat sensors, energy harvesters, energy management, and applications. The review begins with the foundations of wearable sweat sensors, providing an overview of their detection methods, materials, and wearable devices. Then, the working mechanism, structure, and a characteristic of different types of energy harvesters are discussed. The features and challenges of different energy harvesters in energy supply and energy management of sweat sensors are emphasized. The review concludes with a look at the future prospects of self-powered sweat sensors, outlining the trajectory of the field and its potential to flourish.
Collapse
Affiliation(s)
- Nan Gao
- Institute of Intelligent Sport and Proactive Health, Department of Health and Physical Education, Jianghan University, Wuhan, 430056, China
| | - Guodong Xu
- Institute of Intelligent Sport and Proactive Health, Department of Health and Physical Education, Jianghan University, Wuhan, 430056, China
| | - Gang Chang
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China
| | - Yuxiang Wu
- Institute of Intelligent Sport and Proactive Health, Department of Health and Physical Education, Jianghan University, Wuhan, 430056, China
| |
Collapse
|
27
|
Lin F, Vera Anaya D, Gong S, Yap LW, Lu Y, Yong Z, Cheng W. Gold Nanowire Sponge Electrochemistry for Permeable Wearable Sweat Analysis Comfortably and Wirelessly. ACS Sens 2024; 9:5414-5424. [PMID: 39298751 DOI: 10.1021/acssensors.4c01635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Electrochemistry-based wearable and wireless sweat analysis is emerging as a promising noninvasive method for real-time health monitoring by tracking chemical and biological markers without the need for invasive blood sampling. It offers the potential to remotely monitor human sweat conditions in relation to metabolic health, stress, and electrolyte balance, which have implications for athletes, patients with chronic conditions, and individuals for the early detection and management of health issues. The state-of-the-art mainstream technology is dominated by the concept of a wearable microfluidic chip, typically based on elastomeric PDMS. While outstanding sensing performance can be realized, the design suffers from the poor permeability of PDMS, which could cause skin redness or irritation. Here, we introduce an omnidirectionally permeable, deformable, and wearable sweat analysis system based on gold nanowire sponges. We demonstrate the concept of all-in-one soft sponge electrochemistry, where the working, reference, and counter electrodes and electrolytes are all integrated within the sponge matrix. The intrinsic porosity of sponge in conjunction with vertically aligned gold nanowire electrodes gives rise to a high electrochemically active surface area of ∼67 cm2. Remarkably, this all-in-one sponge-based electrochemical system exhibited stable performance under a pressure of 10 kPa and 300% omnidirectional strain. The gold sponge biosensing electrodes could be sandwiched between two biocompatible sweat pads, which can serve as natural sweat collection and outflow layers. This naturally biocompatible and permeable platform can be integrated with wireless communication circuits, leading to a wireless sweat analysis system for the real-time monitoring of glucose, lactate, and pH during exercise.
Collapse
Affiliation(s)
- Fenge Lin
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - David Vera Anaya
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Shu Gong
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Lim Wei Yap
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Yan Lu
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Zijun Yong
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
| | - Wenlong Cheng
- Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton 3800, VIC, Australia
- School of Biomedical Engineering, University of Sydney, Darlington 2008, NSW, Australia
| |
Collapse
|
28
|
Lee S, Ho DH, Jekal J, Cho SY, Choi YJ, Oh S, Choi YY, Lee T, Jang KI, Cho JH. Fabric-based lamina emergent MXene-based electrode for electrophysiological monitoring. Nat Commun 2024; 15:5974. [PMID: 39358330 PMCID: PMC11446925 DOI: 10.1038/s41467-024-49939-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 06/20/2024] [Indexed: 10/04/2024] Open
Abstract
Commercial wearable biosignal sensing technologies encounter challenges associated with irritation or discomfort caused by unwanted objects in direct contact with the skin, which can discourage the widespread adoption of wearable devices. To address this issue, we propose a fabric-based lamina emergent MXene-based electrode, a lightweight and flexible shape-morphing wearable bioelectrode. This work offers an innovative approach to biosignal sensing by harnessing the high electrical conductivity and low skin-to-electrode contact impedance of MXene-based dry electrodes. Its design, inspired by Nesler's pneumatic interference actuator, ensures stable skin-to-electrode contact, enabling robust biosignal detection in diverse situations. Extensive research is conducted on key design parameters, such as the width and number of multiple semicircular legs, the radius of the anchoring frame, and pneumatic pressure, to accommodate a wide range of applications. Furthermore, a real-time wireless electrophysiological monitoring system has been developed, with a signal-to-noise ratio and accuracy comparable to those of commercial bioelectrodes. This work excels in recognizing various hand gestures through a convolutional neural network, ultimately introducing a shape-morphing electrode that provides reliable, high-performance biosignal sensing for dynamic users.
Collapse
Affiliation(s)
- Sanghyun Lee
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea
| | - Dong Hae Ho
- Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Janghwan Jekal
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Soo Young Cho
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea
| | - Young Jin Choi
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea
| | - Saehyuck Oh
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea
| | - Yoon Young Choi
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Taeyoon Lee
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
- Department of Bio and Brain Engineering, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea
| | - Kyung-In Jang
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea.
| | - Jeong Ho Cho
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea.
| |
Collapse
|
29
|
Sun Z, Ou Q, Dong C, Zhou J, Hu H, Li C, Huang Z. Conducting polymer hydrogels based on supramolecular strategies for wearable sensors. EXPLORATION (BEIJING, CHINA) 2024; 4:20220167. [PMID: 39439497 PMCID: PMC11491309 DOI: 10.1002/exp.20220167] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 02/02/2024] [Indexed: 10/25/2024]
Abstract
Conductive polymer hydrogels (CPHs) are gaining considerable attention in developing wearable electronics due to their unique combination of high conductivity and softness. However, in the absence of interactions, the incompatibility between hydrophobic conductive polymers (CPs) and hydrophilic polymer networks gives rise to inadequate bonding between CPs and hydrogel matrices, thereby significantly impairing the mechanical and electrical properties of CPHs and constraining their utility in wearable electronic sensors. Therefore, to endow CPHs with good performance, it is necessary to ensure a stable and robust combination between the hydrogel network and CPs. Encouragingly, recent research has demonstrated that incorporating supramolecular interactions into CPHs enhances the polymer network interaction, improving overall CPH performance. However, a comprehensive review focusing on supramolecular CPH (SCPH) for wearable sensing applications is currently lacking. This review provides a summary of the typical supramolecular strategies employed in the development of high-performance CPHs and elucidates the properties of SCPHs that are closely associated with wearable sensors. Moreover, the review discusses the fabrication methods and classification of SCPH sensors, while also exploring the latest application scenarios for SCPH wearable sensors. Finally, it discusses the challenges of SCPH sensors and offers suggestions for future advancements.
Collapse
Affiliation(s)
- Zhiyuan Sun
- School of Chemical Engineering and TechnologyXi'an Jiaotong UniversityXi'anPeople's Republic of China
| | - Qingdong Ou
- Macao Institute of Materials Science and Engineering (MIMSE)Faculty of Innovation EngineeringMacau University of Science and TechnologyMacao TaipaPeople's Republic of China
| | - Chao Dong
- Chemistry and Physics DepartmentCollege of Art and ScienceThe University of Texas of Permian BasinOdessaTexasUSA
| | - Jinsheng Zhou
- College of Chemistry and Environmental EngineeringShenzhen UniversityShenzhenPeople's Republic of China
| | - Huiyuan Hu
- College of Chemistry and Environmental EngineeringShenzhen UniversityShenzhenPeople's Republic of China
| | - Chong Li
- Guangdong Polytechnic of Science and TechnologyZhuhaiPeople's Republic of China
| | - Zhandong Huang
- School of Chemical Engineering and TechnologyXi'an Jiaotong UniversityXi'anPeople's Republic of China
| |
Collapse
|
30
|
Koumbia M, Ngoepe M, Holman JB, Mufamadi MS, Takai M. Microfluidic electrochemical biosensors: tools for advancing the sustainable development goals. Trends Biotechnol 2024; 42:1207-1210. [PMID: 38714388 DOI: 10.1016/j.tibtech.2024.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 04/11/2024] [Accepted: 04/12/2024] [Indexed: 05/09/2024]
Abstract
New technologies can help to achieve the sustainable development goals (SDGs) of the United Nations. We discuss the contribution of microfluidic electrochemical biosensors to advancing the SDGs. These sensors can be applied in various fields given their low cost, self-powering ability, environmental compatibility, ease of use, and small sample volume requirements.
Collapse
Affiliation(s)
- Mkliwa Koumbia
- School of Engineering, The University of Tokyo, 2-11-16 Yayoi, Bunkyo-Ku, Tokyo 113-8656, Japan
| | - Mpho Ngoepe
- DSI-Mandela Nanomedicine Platform, Nelson Mandela University, Gqeberha, 6001, Eastern Cape, South Africa
| | - Joseph Benjamin Holman
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Maluta Steven Mufamadi
- DSI-Mandela Nanomedicine Platform, Nelson Mandela University, Gqeberha, 6001, Eastern Cape, South Africa
| | - Madoka Takai
- School of Engineering, The University of Tokyo, 2-11-16 Yayoi, Bunkyo-Ku, Tokyo 113-8656, Japan.
| |
Collapse
|
31
|
Liang H, Zhang Y. Revolutionizing wearable healthcare with solid-state epidermal biomarker monitoring. Sci Bull (Beijing) 2024; 69:2650-2652. [PMID: 39089932 DOI: 10.1016/j.scib.2024.07.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/04/2024]
Affiliation(s)
- Huarun Liang
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of Ministry of Education, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Yingying Zhang
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of Ministry of Education, Department of Chemistry, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
32
|
Zhang H, Zhang H, Sikdar D, Liu X, Yang Z, Cheng W, Chen Y. Jellyfish-like Gold Nanowires as FlexoSERS Sensors for Sweat Analysis. NANO LETTERS 2024; 24:11269-11278. [PMID: 39208279 DOI: 10.1021/acs.nanolett.4c02907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
We introduce the FlexoSERS sensor, which is notable for its high stretchability, sensitivity, and patternability. Featuring a hierarchically oriented jellyfish-like architecture constructed from stretchable gold nanowires, this sensor provides an ultrasensitive SERS signal even under 50% strain, with an enhancement factor (EF) of 3.3 × 1010. Impressively, this heightened performance remains consistently robust across 2,500 stretch-release cycles. The integration of nanowires with 3D-printed hydrogel enables a customizable FlexoSERS sensor, facilitating localized sweat collection and detection. The FlexoSERS sensor successfully detects and quantifies uric acid (UA) in both artificial and human sweat and functions as a pH sensor with repeatability and sensitivity across a pH range of 4.2-7.8, enabling real-time sweat monitoring during exercise. In summary, the rational architectural design, scalable fabrication process, and hydrogel integration collectively position this nanowire-based FlexoSERS sensor as a highly promising platform for customizable wearable sweat diagnostics.
Collapse
Affiliation(s)
- Heng Zhang
- State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
- Southeast University-Monash University Joint Graduate School, Suzhou 215123, China
| | - Hanqiang Zhang
- Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 210096, China
| | - Debabrata Sikdar
- Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam India, 781039
| | - Xuanchi Liu
- State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Zongru Yang
- Joint International Research Laboratory of Information Display and Visualization, School of Electronic Science and Engineering, Southeast University, Nanjing 210096, China
| | - Wenlong Cheng
- Faculty of Engineering, The University of Sydney, Darlington, NSW 2008, Australia
| | - Yi Chen
- State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
- Southeast University-Monash University Joint Graduate School, Suzhou 215123, China
| |
Collapse
|
33
|
Childs A, Mayol B, Lasalde-Ramírez JA, Song Y, Sempionatto JR, Gao W. Diving into Sweat: Advances, Challenges, and Future Directions in Wearable Sweat Sensing. ACS NANO 2024; 18:24605-24616. [PMID: 39185844 DOI: 10.1021/acsnano.4c10344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Sweat analysis has advanced from diagnosing cystic fibrosis and testing for illicit drugs to noninvasive monitoring of health biomarkers. This article introduces the rapid development of wearable and flexible sweat sensors, highlighting key milestones and various sensing strategies for real-time monitoring of analytes. We discuss challenges such as developing high-performance nanomaterial-based biosensors, ensuring continuous sweat production and sampling, achieving high sweat/blood correlation, and biocompatibility. The potential of machine learning to enhance these sensors for personalized healthcare is presented, enabling real-time tracking and prediction of physiological changes and disease onset. Leveraging advancements in flexible electronics, nanomaterials, biosensing, and data analytics, wearable sweat biosensors promise to revolutionize disease management, prevention, and prediction, promoting healthier lifestyles and transforming medical practices globally.
Collapse
Affiliation(s)
- Andre Childs
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
| | - Beatriz Mayol
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
| | - José A Lasalde-Ramírez
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Yu Song
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, China
| | - Juliane R Sempionatto
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California 91125, United States
| |
Collapse
|
34
|
Cho S, Shaban SM, Song R, Zhang H, Yang D, Kim MJ, Xiong Y, Li X, Madsen K, Wapnick S, Zhang S, Chen Z, Kim J, Guinto G, Li M, Lee M, Nuxoll RF, Shajari S, Wang J, Son S, Shin J, Aranyosi AJ, Wright DE, Kim TI, Ghaffari R, Huang Y, Kim DH, Rogers JA. A skin-interfaced microfluidic platform supports dynamic sweat biochemical analysis during human exercise. Sci Transl Med 2024; 16:eado5366. [PMID: 39231240 DOI: 10.1126/scitranslmed.ado5366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 06/14/2024] [Accepted: 08/15/2024] [Indexed: 09/06/2024]
Abstract
Blood lactate concentration is an established circulating biomarker for measuring muscle acidity and can be evaluated for monitoring endurance, training routines, or athletic performance. Sweat is an alternative biofluid that may serve similar purposes and offers the advantage of noninvasive collection and continuous monitoring. The relationship between blood lactate and dynamic sweat biochemistry for wearable engineering applications in physiological fitness remains poorly defined. Here, we developed a microfluidic wearable band with an integrated colorimetric timer and biochemical assays that temporally captures sweat and measures pH and lactate concentration. A colorimetric silver nanoplasmonic assay was used to measure the concentration of lactate, and dye-conjugated SiO2 nanoparticle-agarose composite materials supported dynamic pH analysis. We evaluated these sweat biomarkers in relation to blood lactate in human participant studies during cycling exercise of varying intensity. Iontophoresis-generated sweat pH from regions of actively working muscles decreased with increasing heart rate during exercise and was negatively correlated with blood lactate concentration. In contrast, sweat pH from nonworking muscles did not correlate with blood lactate concentration. Changes in sweat pH and blood lactate were observed in participants who did not regularly exercise but not in individuals who regularly exercised, suggesting a relationship to physical fitness and supporting further development for noninvasive, biochemical fitness evaluations.
Collapse
Affiliation(s)
- Soongwon Cho
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Samy M Shaban
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Petrochemical Department, Egyptian Petroleum Research Institute, Cairo, 11727, Egypt
| | - Ruihao Song
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Haohui Zhang
- Departments of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Dasom Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Precision Biology Research Center (PBRC), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Min-Jae Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Yirui Xiong
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Xiuyuan Li
- Departments of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Kenneth Madsen
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Sarena Wapnick
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Shifan Zhang
- Department of Statistics, School of Computer, Data and Information Sciences, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Ziyu Chen
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Jiwon Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Gianna Guinto
- College of Science and Health, DePaul University, Chicago, IL 60614, USA
| | - Michelle Li
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Minkyu Lee
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Shirley Ryan AbilityLab, Chicago, IL 60611, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL 60611, USA
| | - Ravi F Nuxoll
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208, USA
| | - Shaghayegh Shajari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Jin Wang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Pritzker School of Molecular Engineering, University of Chicago, Chicago, IL 60637, USA
| | - Seongeun Son
- Department of Bionano Engineering, Center for Bionano Intelligence Education and Research, Hanyang University, Ansan, 15588, Republic of Korea
| | - Jihoon Shin
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Alexander J Aranyosi
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Epicore Biosystems, Cambridge, MA 02139, USA
| | | | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Epicore Biosystems, Cambridge, MA 02139, USA
| | - Yonggang Huang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Dong-Hwan Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Neurological Surgery, Northwestern University, Evanston, IL 60208, USA
| |
Collapse
|
35
|
Jin M, Su P, Huang X, Zhang R, Xu H, Wang Z, Su C, Katona JM, Ye Y. Micropatterned Polymer Nanoarrays with Distinct Superwettability for a Highly Efficient Sweat Collection and Sensing Patch. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2311380. [PMID: 38721961 DOI: 10.1002/smll.202311380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 03/03/2024] [Indexed: 10/01/2024]
Abstract
Wearable sweat sensor offers a promising means for noninvasive real-time health monitoring, but the efficient collection and accurate analysis of sweat remains challenging. One of the obstacles is to precisely modulate the surface wettability of the microfluidics to achieve efficient sweat collection. Here a facile initiated chemical vapor deposition (iCVD) method is presented to grow and pattern polymer nanocone arrays with distinct superwettability on polydimethylsiloxane microfluidics, which facilitate highly efficient sweat transportation and collection. The nanoarray is synthesized by manipulating monomer supersaturation during iCVD to induce controlled nucleation and preferential vertical growth of fluorinated polymer. Subsequent selective vapor deposition of a conformal hydrogel nanolayer results in superhydrophilic nanoarray floor and walls within the microchannel that provide a large capillary force and a superhydrophobic ceiling that drastically reduces flow friction, enabling rapid sweat transport along varied flow directions. A carbon/hydrogel/enzyme nanocomposite electrode is then fabricated by sequential deposition of highly porous carbon nanoparticles and hydrogel nanocoating to achieve sensitive and stable sweat detection. Further encapsulation of the assembled sweatsensing patch with superhydrophobic nanoarray imparts self-cleaning and water-proof capability. Finally, the sweat sensing patch demonstrates selective and sensitive glucose and lactate detection during the on-body test.
Collapse
Affiliation(s)
- Minghui Jin
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - Peipei Su
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - Xiaocheng Huang
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - Ruhao Zhang
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - He Xu
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - Zhenbo Wang
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - Cuicui Su
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| | - Jaroslav M Katona
- Faculty of Technology, University of Novi Sad, Novi Sad, Bul. Cara Lazara 1, Novi Sad, 21000, Serbia
| | - Yumin Ye
- Department of Materials Science and Engineering, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China
| |
Collapse
|
36
|
Wu J, Zhou X, Luo J, Zhou J, Lu Z, Bai Z, Fan Y, Chen X, Zheng B, Wang Z, Wei L, Zhang Q. Stretchable and Self-Powered Mechanoluminescent Triboelectric Nanogenerator Fibers toward Wearable Amphibious Electro-Optical Sensor Textiles. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2401109. [PMID: 38970168 PMCID: PMC11425994 DOI: 10.1002/advs.202401109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/28/2024] [Indexed: 07/08/2024]
Abstract
Flexible electro-optical dual-mode sensor fibers with capability of the perceiving and converting mechanical stimuli into digital-visual signals show good prospects in smart human-machine interaction interfaces. However, heavy mass, low stretchability, and lack of non-contact sensing function seriously impede their practical application in wearable electronics. To address these challenges, a stretchable and self-powered mechanoluminescent triboelectric nanogenerator fiber (MLTENGF) based on lightweight carbon nanotube fiber is successfully constructed. Taking advantage of their mechanoluminescent-triboelectric synergistic effect, the well-designed MLTENGF delivers an excellent enhancement electrical signal of 200% and an evident optical signal whether on land or underwater. More encouragingly, the MLTENGF device possesses outstanding stability with almost unchanged sensitivity after stretching for 200%. Furthermore, an extraordinary non-contact sensing capability with a detection distance of up to 35 cm is achieved for the MLTENGF. As application demonstrations, MLTENGFs can be used for home security monitoring, intelligent zither, traffic vehicle collision avoidance, and underwater communication. Thus, this work accelerates the development of wearable electro-optical textile electronics for smart human-machine interaction interfaces.
Collapse
Affiliation(s)
- Jiajun Wu
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
- School of Materials Science and EngineeringShanghai Institute of TechnologyShanghai201400China
| | - Xuhui Zhou
- School of Electrical and Electronic EngineeringNanyang Technological University50 Nanyang AvenueSingapore639798Singapore
| | - Jie Luo
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Jianxian Zhou
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Zecheng Lu
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Zhiqing Bai
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Yuan Fan
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Xuedan Chen
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Bin Zheng
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Zhanyong Wang
- School of Materials Science and EngineeringShanghai Institute of TechnologyShanghai201400China
| | - Lei Wei
- School of Electrical and Electronic EngineeringNanyang Technological University50 Nanyang AvenueSingapore639798Singapore
| | - Qichong Zhang
- Key Laboratory of Multifunctional Nanomaterials and Smart SystemsSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| |
Collapse
|
37
|
Li D, Cui T, Xu Z, Xu S, Dong Z, Tao L, Liu H, Yang Y, Ren TL. Designs and Applications for the Multimodal Flexible Hybrid Epidermal Electronic Systems. RESEARCH (WASHINGTON, D.C.) 2024; 7:0424. [PMID: 39130493 PMCID: PMC11310101 DOI: 10.34133/research.0424] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Accepted: 06/17/2024] [Indexed: 08/13/2024]
Abstract
Research on the flexible hybrid epidermal electronic system (FHEES) has attracted considerable attention due to its potential applications in human-machine interaction and healthcare. Through material and structural innovations, FHEES combines the advantages of traditional stiff electronic devices and flexible electronic technology, enabling it to be worn conformally on the skin while retaining complex system functionality. FHEESs use multimodal sensing to enhance the identification accuracy of the wearer's motion modes, intentions, or health status, thus realizing more comprehensive physiological signal acquisition. However, the heterogeneous integration of soft and stiff components makes balancing comfort and performance in designing and implementing multimodal FHEESs challenging. Herein, multimodal FHEESs are first introduced in 2 types based on their different system structure: all-in-one and assembled, reflecting totally different heterogeneous integration strategies. Characteristics and the key design issues (such as interconnect design, interface strategy, substrate selection, etc.) of the 2 multimodal FHEESs are emphasized. Besides, the applications and advantages of the 2 multimodal FHEESs in recent research have been presented, with a focus on the control and medical fields. Finally, the prospects and challenges of the multimodal FHEES are discussed.
Collapse
Affiliation(s)
- Ding Li
- School of Integrated Circuit,
Tsinghua University, Beijing, China
| | - Tianrui Cui
- School of Integrated Circuit,
Tsinghua University, Beijing, China
| | - Zigan Xu
- School of Integrated Circuit,
Tsinghua University, Beijing, China
| | - Shuoyan Xu
- School of Integrated Circuit,
Tsinghua University, Beijing, China
| | - Zirui Dong
- School of Integrated Circuit,
Tsinghua University, Beijing, China
| | - Luqi Tao
- Beijing National Research Center for Information Science and Technology (BNRist),
Tsinghua University, Beijing, China
| | - Houfang Liu
- Beijing National Research Center for Information Science and Technology (BNRist),
Tsinghua University, Beijing, China
| | - Yi Yang
- School of Integrated Circuit,
Tsinghua University, Beijing, China
- Beijing National Research Center for Information Science and Technology (BNRist),
Tsinghua University, Beijing, China
| | - Tian-Ling Ren
- School of Integrated Circuit,
Tsinghua University, Beijing, China
- Beijing National Research Center for Information Science and Technology (BNRist),
Tsinghua University, Beijing, China
| |
Collapse
|
38
|
Wang Y, Li K, Shen W, Huang X, Wu L. Point-of-care testing of methamphetamine and cocaine utilizing wearable sensors. Anal Biochem 2024; 691:115526. [PMID: 38621604 DOI: 10.1016/j.ab.2024.115526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/23/2024] [Accepted: 03/26/2024] [Indexed: 04/17/2024]
Abstract
The imperative for the point-of-care testing of methamphetamine and cocaine in drug abuse prevention necessitates innovative solutions. To address this need, we have introduced a multi-channel wearable sensor harnessing CRISPR/Cas12a system. A CRISPR/Cas12a based system, integrated with aptamers specific to methamphetamine and cocaine, has been engineered. These aptamers function as signal-mediated intermediaries, converting methamphetamine and cocaine into nucleic acid signals, subsequently generating single-stranded DNA to activate the Cas12 protein. Additionally, we have integrated a microfluidic system and magnetic separation technology into the CRISPR system, enabling rapid and precise detection of cocaine and methamphetamine. The proposed sensing platform demonstrated exceptional sensitivity, achieving a detection limit as low as 0.1 ng/mL. This sensor is expected to be used for on-site drug detection in the future.
Collapse
Affiliation(s)
- Ying Wang
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, 210023, PR China
| | - Ke Li
- Center for Materials Synthetic Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, PR China
| | - Weijian Shen
- Animal, Plant and Food Inspection Center of Nanjing Customs District, Nanjing, 210000, PR China
| | - Xingxu Huang
- International Research Center of Synthetic Biology, Nanjing Normal University, Nanjing, 210023, PR China
| | - Lina Wu
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, 210023, PR China; Food Laboratory of Zhongyuan, Luohe, 462300, Henan, PR China.
| |
Collapse
|
39
|
Yao G, Gan X, Lin Y. Flexible self-powered bioelectronics enables personalized health management from diagnosis to therapy. Sci Bull (Beijing) 2024; 69:2289-2306. [PMID: 38821746 DOI: 10.1016/j.scib.2024.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 04/20/2024] [Accepted: 05/13/2024] [Indexed: 06/02/2024]
Abstract
Flexible self-powered bioelectronics (FSPBs), incorporating flexible electronic features in biomedical applications, have revolutionized the human-machine interface since they hold the potential to offer natural and seamless human interactions while overcoming the limitations of battery-dependent power sources. Furthermore, as biosensors or actuators, FSPBs can dynamically monitor physiological signals to reveal real-time health abnormalities and provide timely and precise treatments. Therefore, FSPBs are increasingly shaping the landscape of health monitoring and disease treatment, weaving a sophisticated and personalized bond between humans and health management. Here, we examine the recent advanced progress of FSPBs in developing working mechanisms, design strategies, and structural configurations toward personalized health management, emphasizing its role in clinical medical scenarios from biophysical/biochemical sensors for sensing diagnosis to robust/biodegradable actuators for intervention therapy. Future perspectives on the challenges and opportunities in emerging multifunctional FSPBs for the next-generation health management systems are also forecasted.
Collapse
Affiliation(s)
- Guang Yao
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China; State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China; Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China, Shenzhen 518110, China.
| | - Xingyi Gan
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Yuan Lin
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China; State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China; Medico-Engineering Cooperation on Applied Medicine Research Center, University of Electronic Science and Technology of China, Chengdu 610054, China.
| |
Collapse
|
40
|
Lu W, Wu G, Gan L, Zhang Y, Li K. Functional fibers/textiles for smart sensing devices and applications in personal healthcare systems. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024. [PMID: 39037195 DOI: 10.1039/d4ay01127a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/23/2024]
Abstract
Personalized medical diagnostics and monitoring have become increasingly important due to inefficient and delayed medical services of traditional centralized healthcare systems. To enhance the comfort and portability, flexible health monitoring systems have been developed in recent years. In particular, smart fiber/textile-based sensing devices show superiority for continuously monitoring personal health and vital physiological parameters owing to their light weight, good flexibility and inherent miniaturization. This review focuses on the recent advances in smart fiber/textile-based sensing devices for wearable electronic applications. First, fabrication strategies of smart sensing fibers/textiles are introduced in detail. In addition, sensing performances, working principles and applications of smart sensing fibers/textiles such as pressure sensing fibers/textiles, stretchable strain sensing fibers/textiles, temperature sensing fibers/textiles, and biofluid, gas and humidity sensing fibers/textiles in health monitoring are also reviewed systematically. Finally, we propose current challenges and future prospects in the area of fiber/textile-based sensors for wearable healthcare monitoring and diagnosis systems. In general, this review aims to give an overall perspective of the promising field by reviewing various fiber/textile-based sensing devices and highlighting the importance for researchers to keep up with the sequential exploration of soft sensing fibers/textiles for applications in wearable smart systems.
Collapse
Affiliation(s)
- Wangdong Lu
- Key Laboratory of Modern Measurement & Control Technology, Ministry of Education, Beijing Information Science & Technology University, Beijing 100192, China.
| | - Guoxin Wu
- Key Laboratory of Modern Measurement & Control Technology, Ministry of Education, Beijing Information Science & Technology University, Beijing 100192, China.
| | - Linli Gan
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Yingying Zhang
- Key Laboratory of Organic Optoelectronics and Molecular Engineering of the Ministry of Education, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Kai Li
- College of Science, China University of Petroleum, Beijing, Beijing 102249, China
| |
Collapse
|
41
|
Amers EL, Orme BV, Shi Y, Torun H, Dodd LE. Embroidered Interdigitated Electrodes (IDTs) with Wireless Readout for Continuous Biomarker Monitoring. SENSORS (BASEL, SWITZERLAND) 2024; 24:4643. [PMID: 39066041 PMCID: PMC11280827 DOI: 10.3390/s24144643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Revised: 07/04/2024] [Accepted: 07/12/2024] [Indexed: 07/28/2024]
Abstract
Non-invasive continuous health monitoring has become feasible with the advancement of biosensors. While monitoring certain biomarkers such as heart rate or skin temperature are now at a certain maturity, monitoring molecular biomarkers is still challenging. Progress has been shown in sampling, measurement, and interpretation of data toward non-invasive molecular sensors that can be integrated into daily wearable items. Toward this goal, this paper explores the potential of embroidered interdigitated transducer (IDT)-based sensors for non-invasive, continuous monitoring of human biomarkers, particularly glucose levels, in human sweat. The study employs innovative embroidery techniques to create flexible fabric-based sensors with gold-coated IDTs. In controlled experiments, we have shown the variation of glucose concentration in water can be wirelessly detected by tracking the resonant frequency of the embroidered sensors. The current sensors operate at 1.8 GHz to 2 GHz and respond to the change in glucose concentration with a sensitivity of 0.17 MHz/(mg/dL). The embroidered IDT-based sensors with wireless sensing will be a new measurement modality for molecular wearable sensors. The establishment of a wireless sensing mechanism for embroidered IDT-based sensors will be followed by an investigation of sweat for molecular detection. This will require adding functionalities for sampling and interpretation of acquired data. We envisage the embroidered IDT-based sensors offer a unique approach for seamless integration into clothing, paving the way for personalised, continuous health data capture.
Collapse
Affiliation(s)
- Emmy L. Amers
- Smart Materials & Surfaces Laboratory—E-Textiles Centre, Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK (H.T.)
| | - Bethany V. Orme
- Smart Materials & Surfaces Laboratory—E-Textiles Centre, Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK (H.T.)
| | - Yuyuan Shi
- Digital Textile Lab, School of Design, Faculty of Arts, Design and Social Sciences, Northumbria University, Newcastle upon Tyne NE1 8ST, UK
| | - Hamdi Torun
- Smart Materials & Surfaces Laboratory—E-Textiles Centre, Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK (H.T.)
| | - Linzi E. Dodd
- Smart Materials & Surfaces Laboratory—E-Textiles Centre, Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK (H.T.)
| |
Collapse
|
42
|
Wang Z, Xiao M, Li Z, Wang X, Li F, Yang H, Chen Y, Zhu Z. Microneedle Patches-Integrated Transdermal Bioelectronics for Minimally Invasive Disease Theranostics. Adv Healthc Mater 2024; 13:e2303921. [PMID: 38341619 DOI: 10.1002/adhm.202303921] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/29/2024] [Indexed: 02/12/2024]
Abstract
Wearable epidermal electronics with non- or minimally-invasive characteristics can collect, transduce, communicate, and interact with accessible physicochemical health indicators on the skin. However, due to the stratum corneum layer, rich information about body health is buried under the skin stratum corneum layer, for example, in the skin interstitial fluid. Microneedle patches are typically designed with arrays of special microsized needles of length within 1000 µm. Such characteristics potentially enable the access and sample of biomolecules under the skin or give therapeutical treatment painlessly and transdermally. Integrating microneedle patches with various electronics allows highly efficient transdermal bioelectronics, showing their great promise for biomedical and healthcare applications. This comprehensive review summarizes and highlights the recent progress on integrated transdermal bioelectronics based on microneedle patches. The design criteria and state-of-the-art fabrication techniques for such devices are initially discussed. Next, devices with different functions, including but not limited to health monitoring, drug delivery, and therapeutical treatment, are highlighted in detail. Finally, key issues associated with current technologies and future opportunities are elaborated to sort out the state of recent research, point out potential bottlenecks, and provide future research directions.
Collapse
Affiliation(s)
- Zifeng Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, China
| | - Min Xiao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, China
| | - Zhanhong Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, China
| | - Xinghao Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, China
| | - Fangjie Li
- School of Acupuncture-Moxibustion and Tuina, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai, 201203, China
| | - Huayuan Yang
- School of Acupuncture-Moxibustion and Tuina, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai, 201203, China
| | - Yu Chen
- Materdicine Lab, School of Life Sciences, Shanghai University, 99 Shangda Road, Shanghai, 200444, China
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, 200093, China
- Health Industry Innovation Center, Xin-Huangpu Joint Innovation Institute of Chinese Medicine, 81 Xiangxue Middle Avenue, Huangpu District, Guangzhou, Guangdong Province, 510799, China
| |
Collapse
|
43
|
Yin Y, Tan Z, Zhu W, Pu Z, Yu H, Wang R, Li D. A wearable microfluidic system for efficient sweat collection and real-time detection. Talanta 2024; 274:125967. [PMID: 38537349 DOI: 10.1016/j.talanta.2024.125967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/01/2024] [Accepted: 03/20/2024] [Indexed: 05/04/2024]
Abstract
Sweat is an important biofluid with rich physiological information that can evaluate human health condition. Wearable sweat sensors have received widespread attention in recent years due to the benefits of non-invasive, continuous, and real-time monitoring. Currently, an efficient device integrating sweat collection and detection is still needed. Here, a wearable sweat microfluidic system was fabricated for real-time collection and analysis of sweat. The fabricated microfluidic system consisted of four layers, including a skin adhesive layer, a microfluidic layer, an electrode layer, and a capping layer. The sweat collection rate was around 0.79 μL/min, which demonstrated efficient sweat sampling, storage, and refreshing capabilities. Simultaneous detection of multiple sweat biomarkers was achieved with a screen-printed sweat sensing array, which could realize high-precision detection of Na+, K+, and glucose. Moreover, the sensing array also showed good repeatability and stability, with a relative standard deviation of sensitivity of less than 5%. Additionally, human testing was conducted to demonstrate that this microfluidic system can continuously monitor Na+, K+, and glucose in subjects' sweat during exercise, which showed high potential for non-invasive human health monitoring.
Collapse
Affiliation(s)
- Yingda Yin
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China
| | - Zhiguang Tan
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China
| | - Wangwang Zhu
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China
| | - Zhihua Pu
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China
| | - Haixia Yu
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China
| | - Ridong Wang
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China.
| | - Dachao Li
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, 300072, China.
| |
Collapse
|
44
|
Peng HL, Zhang Y, Liu H, Gao C. Flexible Wearable Electrochemical Sensors Based on AuNR/PEDOT:PSS for Simultaneous Monitoring of Levodopa and Uric Acid in Sweat. ACS Sens 2024; 9:3296-3306. [PMID: 38829039 DOI: 10.1021/acssensors.4c00649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2024]
Abstract
As a facile substitute for the invasive technique of blood testing, wearable electrochemical sensors exhibit high potential for the noninvasive and real-time monitoring of biomarkers in human sweat. However, owing to enzyme specificity, the simultaneous detection of multiple biomarkers by enzymatic analysis is challenging. Moreover, sweat accumulation under sensors causes sweat contamination, which hinders real-time biomarker detection from sweat. This study reports the design and fabrication of flexible wearable electrochemical sensors containing a composite comprising Au nanorods (AuNRs) and poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) for the nonenzymatic detection of levodopa (LD) and uric acid (UA) in sweat. Each sensor was integrated with a flexible three-electrode system and a microfluidic patch for sweat sampling. AuNRs immobilized by PEG-doped PEDOT:PSS showed excellent analytical performance for LD and UA at different potentials. Thus, the newly fabricated sensors could detect LD and UA over a broad detection range with high sensitivity and showed a low limit of detection for both species. On-body assessments confirmed the ability of these sensors to simultaneously detect LD and UA in real time. Therefore, this study could open new frontiers in the fabrication of wearable electrochemical sensors for the pharmacokinetic profile tracking of LD and gout management.
Collapse
Affiliation(s)
- Hui-Ling Peng
- Key Laboratory of Integrated Circuits and Microsystems (Guangxi Normal University), Education Department of Guangxi Zhuang Autonomous Region, School of Electronic and Information Engineering/School of Integrated Circuits, Guangxi Normal University, Guilin 541004, People's Republic of China
| | - Yongqi Zhang
- Key Laboratory of Integrated Circuits and Microsystems (Guangxi Normal University), Education Department of Guangxi Zhuang Autonomous Region, School of Electronic and Information Engineering/School of Integrated Circuits, Guangxi Normal University, Guilin 541004, People's Republic of China
| | - Huihui Liu
- State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Collaborative Innovation Center for Guangxi Ethnic Medicine, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004, People's Republic of China
| | - Cunji Gao
- State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Collaborative Innovation Center for Guangxi Ethnic Medicine, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004, People's Republic of China
| |
Collapse
|
45
|
Wu Y, Hou D, Zheng Y, Lin X, Yang F, Liu C, Sun H. Preparation of Conductive Cellulose Coated with Conductive Polymer and Its Application in the Detection of pH and Characteristic Substances in Sweat. Int J Mol Sci 2024; 25:6393. [PMID: 38928100 PMCID: PMC11203626 DOI: 10.3390/ijms25126393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 06/05/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024] Open
Abstract
Rich biological information in sweat provides great potential for health monitoring and management. However, due to the complexity of sweat, the development of environmentally friendly green electronic products is of great significance to the construction of ecological civilization. This study utilized a simple combination of polystyrene sulfonate sodium (PSS) and filter paper (FP) to prepare cellulose materials coated with conductive polymers, developing an electrochemical sensor based on the modified materials. The mechanical and electrochemical properties of the fabricated PSS/FP membrane were optimized by adjusting the feeding dosage of PSS. The realized PSS/FP composite containing 7% PSS displayed good conductivity (9.1 × 10-2 S/m), reducing electric resistance by 99.2% compared with the original FP membrane (6.7 × 10-4 S/m). The stable current of the membrane in simulated sweat under different pH environments is highly correlated with the pH values. Additionally, when the membrane is exposed to simulated sweat with varying ion concentrations, the current signal changes in real time with the concentration variations. The response time averages around 0.3 s.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Hao Sun
- International Joint Research Center for Biomass Materials, Southwest Forestry University, Kunming 650224, China; (Y.W.); (D.H.); (Y.Z.); (X.L.); (F.Y.); (C.L.)
| |
Collapse
|
46
|
Phamonpon W, Hinestroza JP, Puthongkham P, Rodthongkum N. Surface-engineered natural fibers: Emerging alternative substrates for chemical sensor applications: A review. Int J Biol Macromol 2024; 269:132185. [PMID: 38723830 DOI: 10.1016/j.ijbiomac.2024.132185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Revised: 04/26/2024] [Accepted: 05/06/2024] [Indexed: 05/14/2024]
Abstract
Natural fiber has become one of the most widely used alternative materials for chemical sensor fabrication due to its advantages, such as biocompatibility, flexibility, and self-microfluidic properties. Enhanced natural fiber surface has been used as a substrate in colorimetric and electrochemical sensors. This review focuses on improving the natural fiber properties for preparation as a substrate for chemical sensors. Various methods for natural fiber extraction are discussed and compared. Bleaching and decolorization is important for preparation of colorimetric sensors, while carbonization and nanoparticle doping are favorable for increasing their electrical conductivity for electrochemical sensor fabrication. Also, example fabrications and applications of natural fiber-based chemical sensors for chemical and biomarker detection are discussed. The selectivity of the sensors can be introduced and improved by surface modification of natural fiber, such as enzyme immobilization and biorecognition element functionalization, illustrating the adaptability of natural fiber as a smart sensing device, e.g., wearable and portable sensors. Ultimately, the high performances of natural fiber-based chemical sensors indicate the potential uses of natural fiber as a renewable and eco-friendly substrate material in the field of chemical sensors and biosensors for clinical diagnosis and environmental monitoring.
Collapse
Affiliation(s)
- Wisarttra Phamonpon
- Nanoscience and Technology Program, Graduate School, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Juan P Hinestroza
- Department of Fiber Science, College of Human Ecology, Cornell University, Ithaca, NY 14850, United States
| | - Pumidech Puthongkham
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand.
| | - Nadnudda Rodthongkum
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand.
| |
Collapse
|
47
|
Zhao Z, Ke X, Huang J, Zhang Z, Wu Y, Huang G, Tan J, Liu X, Mei Y, Chu J. Design and Synthesis of Transferrable Macro-Sized Continuous Free-Standing Metal-Organic Framework Films for Biosensor Device. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2310189. [PMID: 38468446 PMCID: PMC11187891 DOI: 10.1002/advs.202310189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 02/10/2024] [Indexed: 03/13/2024]
Abstract
Metal organic framework (MOF) films have attracted abundant attention due to their unique characters compared with MOF particles. But the high-temperature reaction and solvent corrosion limit the preparation of MOF films on fragile substrates, hindering further applications. Fabricating macro-sized continuous free-standing MOF films and transferring them onto fragile substrates are a promising alternative but still challenging. Here, a universal strategy to prepare transferrable macro-sized continuous free-standing MOF films with the assistance of oxide nanomembranes prepared by atomic layer deposition and studied the growth mechanism is developed. The oxide nanomembranes serve not only as reactant, but also as interfacial layer to maintain the integrality of the free-standing structure as the stacked MOF particles are supported by the oxide nanomembrane. The centimeter-scale free-standing MOF films can be transferred onto fragile substrates, and all in one device for glucose sensing is assembled. Due to the strong adsorption toward glucose molecules, the obtained devices exhibit outstanding performance in terms of high sensitivity, low limit of detection, and long durability. This work opens a new window toward the preparation of MOF films and MOF film-based biosensor chip for advantageous applications in post-Moore law period.
Collapse
Affiliation(s)
- Zhe Zhao
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- College of Biological Science and Medical EngineeringDonghua UniversityShanghai201620P. R. China
- Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of OptoelectronicsFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Xinyi Ke
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of OptoelectronicsFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Jiayuan Huang
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Ziyu Zhang
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Yue Wu
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Gaoshan Huang
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Ji Tan
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of CeramicsChinese Academy of SciencesShanghai200050P. R. China
| | - Xuanyong Liu
- College of Biological Science and Medical EngineeringDonghua UniversityShanghai201620P. R. China
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of CeramicsChinese Academy of SciencesShanghai200050P. R. China
| | - Yongfeng Mei
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of OptoelectronicsFudan UniversityShanghai200438P. R. China
- Yiwu Research Institute of Fudan UniversityYiwuZhejiang322000P. R. China
- International Institute of Intelligent Nanorobots and NanosystemsFudan UniversityShanghai200438P. R. China
| | - Junhao Chu
- Department of Materials Science & State Key Laboratory of Molecular Engineering of PolymersFudan UniversityShanghai200438P. R. China
- Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of OptoelectronicsFudan UniversityShanghai200438P. R. China
| |
Collapse
|
48
|
Lee S, Liang X, Kim JS, Yokota T, Fukuda K, Someya T. Permeable Bioelectronics toward Biointegrated Systems. Chem Rev 2024; 124:6543-6591. [PMID: 38728658 DOI: 10.1021/acs.chemrev.3c00823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2024]
Abstract
Bioelectronics integrates electronics with biological organs, sustaining the natural functions of the organs. Organs dynamically interact with the external environment, managing internal equilibrium and responding to external stimuli. These interactions are crucial for maintaining homeostasis. Additionally, biological organs possess a soft and stretchable nature; encountering objects with differing properties can disrupt their function. Therefore, when electronic devices come into contact with biological objects, the permeability of these devices, enabling interactions and substance exchanges with the external environment, and the mechanical compliance are crucial for maintaining the inherent functionality of biological organs. This review discusses recent advancements in soft and permeable bioelectronics, emphasizing materials, structures, and a wide range of applications. The review also addresses current challenges and potential solutions, providing insights into the integration of electronics with biological organs.
Collapse
Affiliation(s)
- Sunghoon Lee
- Thin-Film Device Laboratory & Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
| | - Xiaoping Liang
- Electrical and Electronic Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Joo Sung Kim
- Thin-Film Device Laboratory & Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
| | - Tomoyuki Yokota
- Electrical and Electronic Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Kenjiro Fukuda
- Thin-Film Device Laboratory & Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
| | - Takao Someya
- Thin-Film Device Laboratory & Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
- Electrical and Electronic Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| |
Collapse
|
49
|
Song Y, Hu C, Wang Z, Wang L. Silk-based wearable devices for health monitoring and medical treatment. iScience 2024; 27:109604. [PMID: 38628962 PMCID: PMC11019284 DOI: 10.1016/j.isci.2024.109604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024] Open
Abstract
Previous works have focused on enhancing the tensile properties, mechanical flexibility, biocompatibility, and biodegradability of wearable devices for real-time and continuous health management. Silk proteins, including silk fibroin (SF) and sericin, show great advantages in wearable devices due to their natural biodegradability, excellent biocompatibility, and low fabrication cost. Moreover, these silk proteins possess great potential for functionalization and are being explored as promising candidates for multifunctional wearable devices with sensory capabilities and therapeutic purposes. This review introduces current advancements in silk-based constituents used in the assembly of wearable sensors and adhesives for detecting essential physiological indicators, including metabolites in body fluids, body temperature, electrocardiogram (ECG), electromyogram (EMG), pulse, and respiration. SF and sericin play vital roles in addressing issues related to discomfort reduction, signal fidelity improvement, as well as facilitating medical treatment. These developments signify a transition from hospital-centered healthcare toward individual-centered health monitoring and on-demand therapeutic interventions.
Collapse
Affiliation(s)
- Yu Song
- Department of Clinical Laboratory, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Research Center for Tissue Engineering and Regenerative Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Key Laboratory of Regenerative Medicine and Multi-disciplinary Translational Research, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Provincial Engineering Research Center of Clinical Laboratory and Active Health Smart Equipment, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Chuting Hu
- Department of Clinical Laboratory, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Research Center for Tissue Engineering and Regenerative Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Key Laboratory of Regenerative Medicine and Multi-disciplinary Translational Research, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Provincial Engineering Research Center of Clinical Laboratory and Active Health Smart Equipment, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Zheng Wang
- Research Center for Tissue Engineering and Regenerative Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Department of Gastrointestinal Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Key Laboratory of Regenerative Medicine and Multi-disciplinary Translational Research, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Provincial Engineering Research Center of Clinical Laboratory and Active Health Smart Equipment, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Lin Wang
- Department of Clinical Laboratory, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Research Center for Tissue Engineering and Regenerative Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Key Laboratory of Regenerative Medicine and Multi-disciplinary Translational Research, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Hubei Provincial Engineering Research Center of Clinical Laboratory and Active Health Smart Equipment, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| |
Collapse
|
50
|
Li Q, Zou K, Zhang Y. Artificial-intelligence-reinforced multimodal electronic skin for psychological stress assessment. Sci Bull (Beijing) 2024; 69:1173-1175. [PMID: 38538459 DOI: 10.1016/j.scib.2024.03.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2024]
Affiliation(s)
- Qianming Li
- National Laboratory of Solid State Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Chemistry and Biomedicine Innovation Center, Collaborative Innovation Center of Advanced Microstructures, College of Engineering and Applied Sciences, Nanjing University, Nanjing 210023, China
| | - Kuangyi Zou
- National Laboratory of Solid State Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Chemistry and Biomedicine Innovation Center, Collaborative Innovation Center of Advanced Microstructures, College of Engineering and Applied Sciences, Nanjing University, Nanjing 210023, China
| | - Ye Zhang
- National Laboratory of Solid State Microstructures, Jiangsu Key Laboratory of Artificial Functional Materials, Chemistry and Biomedicine Innovation Center, Collaborative Innovation Center of Advanced Microstructures, College of Engineering and Applied Sciences, Nanjing University, Nanjing 210023, China.
| |
Collapse
|