1
|
Park H, Shin GW, Lee SM, Jeong GW, Kim HY, Kim H, Choi HW, Lee-Kwon W, Kwon HM. One-hit kill: On the inactivation of RNA viruses by ultraviolet (UV)-C-induced genomic damage. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2024; 257:112949. [PMID: 38865816 DOI: 10.1016/j.jphotobiol.2024.112949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 05/19/2024] [Accepted: 05/27/2024] [Indexed: 06/14/2024]
Abstract
Large scale outbreaks of infectious respiratory disease have repeatedly plagued the globe over the last 100 years. The scope and strength of the outbreaks are getting worse as pathogenic RNA viruses are rapidly evolving and highly evasive to vaccines and anti-viral drugs. Germicidal UV-C is considered as a robust agent to disinfect RNA viruses regardless of their evolution. While genomic damage by UV-C has been known to be associated with viral inactivation, the precise relationship between the damage and inactivation remains unsettled as genomic damage has been analyzed in small areas, typically under 0.5 kb. In this study, we assessed genomic damage by the reduced efficiency of reverse transcription of regions of up to 7.2 kb. Our data seem to indicate that genomic damage was directly proportional to the size of the genome, and a single hit of damage was sufficient for inactivation of RNA viruses. The high efficacy of UV-C is already effectively adopted to inactivate airborne RNA viruses.
Collapse
Affiliation(s)
- Hyun Park
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea
| | - Go Woon Shin
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea
| | - Sang Min Lee
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea
| | - Gyu Won Jeong
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea
| | - Hui Young Kim
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea
| | - Hajin Kim
- Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea
| | | | - Whaseon Lee-Kwon
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea.
| | - Hyug Moo Kwon
- Department of Biological Sciences and Biomedical Engineering, Ulsan National Institute of Science and Technology Ulsan, Republic of Korea.
| |
Collapse
|
2
|
Rito B, Matos L, Proença DN, Morais PV. Kinetics of inactivation of bacteria responsible for infections in hospitals using UV-LED. Heliyon 2024; 10:e30738. [PMID: 38765034 PMCID: PMC11096922 DOI: 10.1016/j.heliyon.2024.e30738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 04/30/2024] [Accepted: 05/03/2024] [Indexed: 05/21/2024] Open
Abstract
Controlling the microbial load in the environment is crucial to prevent the spread of organisms. The continuous spread of nosocomial infections in hospital facilities and the emergence of the coronavirus (COVID-19) highlighted the importance of disinfection processes in health safety. This work aimed to evaluate the effectiveness of LED-based disinfection lamps on bacteria from the ESKAPEE group and virus phage in vitro inactivation to be applied in hospital environments and health facilities disinfection. This study evaluated the effect of different UV wavelengths (275 nm, 280 nm (UVC), 310 nm (UVB) and 340 nm (UVA)) on the disinfection process of various microbial indicators including E. coli, S. aureus, P. aeruginosa, B. subtilis and Bacteriophage lambda DSM 4499. Exposure time (5 min-30 min), exposure distance (0.25 m and 0.5 m) and surface materials (glass, steel, and polished wood) were evaluated on the disinfection efficiency. Furthermore, the study determined the recovery capacity of each species after UV damage. UVC-LED lamps could inactivate 99.99 % of microbial indicators after 20 min exposures at a 0.5 m distance. The exposure time needed to completely inactivate E. coli, S. aureus, P. aeruginosa, B. subtilis and Bacteriophage lambda DSM 4499 can be decreased by reducing the exposure distance. UVB-LED and UVA-LED lamps were not able to promote a log reduction of 4 and were not effective on B. subtilis or bacteriophage lambda DSM 4499 inactivation. Thus, only UVC-LED lamps were tested on the decontamination of different surface materials, which was successful. P. aeruginosa showed the ability to recover from UV damage, but its inactivation rate remains 99.99 %, and spores from B. subtilis were not completely inactivated. Nevertheless, the inactivation rate of these indicators remained at 99.99 % with 24 h incubation after UVC irradiation. UVC-LED lamps emitting 280 nm were the most indicated to disinfect surfaces from microorganisms usually found in hospital environments.
Collapse
Affiliation(s)
- Beatriz Rito
- University of Coimbra, Centre for Mechanical Engineering, Materials and Processes, ARISE, Department of Life Sciences, Calcada Martim de Freitas, 3000-456, Coimbra, Portugal
| | - Leonor Matos
- University of Coimbra, Centre for Mechanical Engineering, Materials and Processes, ARISE, Department of Life Sciences, Calcada Martim de Freitas, 3000-456, Coimbra, Portugal
| | - Diogo N. Proença
- University of Coimbra, Centre for Mechanical Engineering, Materials and Processes, ARISE, Department of Life Sciences, Calcada Martim de Freitas, 3000-456, Coimbra, Portugal
| | - Paula V. Morais
- University of Coimbra, Centre for Mechanical Engineering, Materials and Processes, ARISE, Department of Life Sciences, Calcada Martim de Freitas, 3000-456, Coimbra, Portugal
| |
Collapse
|
3
|
Wang S, Shao Z, Chen G, Lin B, Li D, Chen J. Assessment of chlorine and hydrogen peroxide on airborne bacteria: Disinfection efficiency and induction of antibiotic resistance. JOURNAL OF HAZARDOUS MATERIALS 2024; 474:134697. [PMID: 38823102 DOI: 10.1016/j.jhazmat.2024.134697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 04/23/2024] [Accepted: 05/21/2024] [Indexed: 06/03/2024]
Abstract
Airborne pathogens severely threaten public health worldwide. Air disinfection is essential to ensure public health. However, excessive use of disinfectants may endanger environmental and ecological security due to the residual disinfectants and their by-products. This study systematically evaluated disinfection efficiency, induction of multidrug resistance, and the underlying mechanisms of disinfectants (NaClO and H2O2) on airborne bacteria. The results showed that airborne bacteria were effectively inactivated by atomized NaClO (>160 μg/L) and H2O2 (>320 μg/L) after 15 min. However, some bacteria still survived after disinfection by atomized NaClO (0-80 μg/L) and H2O2 (0-160 μg/L), and they exhibited significant increases in antibiotic resistance. The whole-genome sequencing of the resistant bacteria revealed distinct mutations that were responsible for both antibiotic resistance and virulence. This study also provided evidences and insights into possible mechanisms underlying the induction of antibiotic resistance by air disinfection, which involved intracellular reactive oxygen species formation, oxidative stress responses, alterations in bacterial membranes, activation of efflux pumps, and the thickening of biofilms. The present results also shed light on the role of air disinfection in inducing antibiotic resistance, which could be a crucial factor contributing to the global spread of antibiotic resistance through the air.
Collapse
Affiliation(s)
- Siyi Wang
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3), Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China
| | - Zhiwei Shao
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3), Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China
| | - Guang Chen
- Shanghai Chengtou Sewage Treatment Co., LtD., Shanghai 201203, China
| | - Bingjie Lin
- Shanghai Chengtou Sewage Treatment Co., LtD., Shanghai 201203, China
| | - Dan Li
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3), Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China.
| | - Jianmin Chen
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3), Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China
| |
Collapse
|
4
|
Monika, Madugula SK, Kondabagil K, Kunwar A. Far-UVC (222 nm) irradiation effectively inactivates ssRNA, dsRNA, ssDNA, and dsDNA viruses as compared to germicidal UVC (254 nm). Photochem Photobiol 2024. [PMID: 38736273 DOI: 10.1111/php.13961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/23/2024] [Accepted: 04/24/2024] [Indexed: 05/14/2024]
Abstract
Ultraviolet-C (UVC) irradiation is being used as an effective approach for the disinfection of pathogenic viruses present in air, surfaces, and water. Recently, far-UVC radiation (222 nm) emitted by KrCl* (krypton-chloride) excimer lamps have been recommended for disinfecting high-risk public spaces to reduce the presence and transmission of infectious viruses owing to limited human health exposure risks as compared to germicidal UVC (254 nm). In this study, the UVC inactivation performances of individual filtered KrCl* excimer lamp (222 nm) and germicidal UVC lamp (254 nm) were determined against four viruses, bacteriophages MS2, Phi6, M13, and T4, having different genome compositions (ssRNA, dsRNA, ssDNA and dsDNA, respectively) and shapes (i.e., spherical (Phi6), linear (M13), and icosahedral (MS2 and T4)). Here, the disinfection efficacies of filtered KrCl* excimer lamp (222 nm) and germicidal UVC lamp (254 nm) were evaluated for highly concentrated virus droplets that mimic the virus-laden droplets released from the infected person and deposited on surfaces as fomites. Filtered KrCl* excimer (222 nm) showed significantly better inactivation against all viruses having different genome compositions and structures compared to germicidal UVC (254 nm). The obtained sensitivity against the filtered KrCl* excimer (222 nm) was found to be in the order, T4 > M13 > Phi6 > MS2 whereas for the germicidal UVC (254 nm) it was T4 > M13 > MS2 > Phi6. These results provide a strong basis to promote the use of filtered KrCl* excimer lamps (222 nm) in disinfecting contagious viruses and to limit the associated disease spread in public places and other high-risk areas.
Collapse
Affiliation(s)
- Monika
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Santhosh Kumar Madugula
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Kiran Kondabagil
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Ambarish Kunwar
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
- Koita Centre for Digital Health (KCDH), Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| |
Collapse
|
5
|
Lu YH, Wang RX, Liu HL, Lai ACK. Evaluating the Performance of UV Disinfection across the 222-365 nm Spectrum against Aerosolized Bacteria and Viruses. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6868-6877. [PMID: 38593035 DOI: 10.1021/acs.est.3c08675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Bioaerosols play a significant role in the transmission of many infectious diseases, especially in enclosed indoor environments. Ultraviolet (UV) disinfection has demonstrated a high efficacy in inactivating microorganisms suspended in the air. To develop more effective and efficient UV disinfection protocols, it is necessary to evaluate and optimize the effectiveness of UV disinfection against aerosolized bacteria and viruses across the entire UV spectrum. In this study, we evaluated the performance of UV disinfection across the UV spectrum, ranging from 222 to 365 nm, against aerosolized bacteria and viruses, including Escherichia coli, Staphylococcus epidermidis, Salmonella enterica, MS2, P22, and Phi6. Six commonly available UV sources, including gas discharge tubes and light-emitting diodes with different emission spectra, were utilized, and their performance in terms of inactivation efficacy, action spectrum, and energy efficiency was determined. Among these UV sources, the krypton chloride excilamp emitting at a peak wavelength of 222 nm was the most efficient in inactivating viral bioaerosols. A low-pressure mercury lamp emitting at 254 nm performed well on both inactivation efficacy and energy efficiency. A UV light-emitting diode emitting at 268 nm demonstrated the highest bacterial inactivation efficacy, but required approximately 10 times more energy to achieve an equivalent inactivation level compared with that of the krypton chloride excilamp and low-pressure mercury lamp. This study provides insights into UV inactivation on bioaerosols, which can guide the development of effective wavelength-targeted UV air disinfection technologies and may significantly help reduce bioaerosol transmission in public areas.
Collapse
Affiliation(s)
- Y H Lu
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - R X Wang
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - H L Liu
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - A C K Lai
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| |
Collapse
|
6
|
Yong SS, Lee JI, Kang DH. Airborne survival and stress response in Listeria monocytogenes across different growth temperatures. JOURNAL OF HAZARDOUS MATERIALS 2024; 468:133706. [PMID: 38364578 DOI: 10.1016/j.jhazmat.2024.133706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 01/29/2024] [Accepted: 02/01/2024] [Indexed: 02/18/2024]
Abstract
In the food industry, ensuring food safety during transportation and storage is vital, with temperature regulation preventing spoilage. However, airborne contamination through foodborne pathogens remains a concern. Listeria monocytogenes, a psychrotolerant foodborne pathogen, has been linked to various foodborne outbreaks. Therefore, understanding how its airborne characteristics depend on the growth temperature is imperative. As a result, when the L. monocytogenes was floated in air for 30 and 60 min, the surviving population of 15 °C-grown L. monocytogenes that was suspended in air and attached on the surface was significantly higher than L. monocytogenes grown at 25°C and 37 °C. The fatty acid analysis revealed a significantly higher proportion of shorter chain fatty acids in L. monocytogenes grown at 15 °C compared to those grown at 37 °C. Under aerosolization, L. monocytogenes encountered osmotic and cold stresses regardless of their growth temperature. Transcriptomic analysis showed that stress response related genes, such as oxidative and cold stress response, as well as PTS system related genes were upregulated at 15 °C, resulting in the enhanced resistance to various stresses during aerosolization. These results provide insights into the different responses of aerosolized L. monocytogenes according to the different growth temperatures, highlighting a critical factor in preventing airborne cross-contamination.
Collapse
Affiliation(s)
- So-Seum Yong
- Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, and Research Institute of Agricultural and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea
| | - Jae-Ik Lee
- Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, and Research Institute of Agricultural and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea
| | - Dong-Hyun Kang
- Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, and Research Institute of Agricultural and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea; Institutes of Green Bio Science & Technology, Seoul National University, Pyeongchang-gun, Gangwon-do 25354, Republic of Korea.
| |
Collapse
|
7
|
Frizziero L, Donnici G, Venditti G, Freddi M. Design of an innovative sanitation system for bike-sharing service. Heliyon 2024; 10:e26595. [PMID: 38420367 PMCID: PMC10900996 DOI: 10.1016/j.heliyon.2024.e26595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 01/27/2024] [Accepted: 02/15/2024] [Indexed: 03/02/2024] Open
Abstract
The concept of a novel sanitization device specifically designed for helmets used in bike share services is presented in this scientific work. The system uses ozone, a powerful oxidizing agent, to completely remove dust and bacteria from the helmet surface. Throughout the development process, special attention has been paid to the dual initial goals of efficacy in removing dirt and batteries, as well as ease of use related to the device's safety. In fact, today's sharing services are rarely capable of providing adequate disinfection of the tools, which is especially troubling given the most recent years of pandemic caused by Covid-19. The invention of the ozone-based sanitization device addresses the growing concern about hygiene and safety in bike share services. Furthermore, due to its portability and ease of use, the device is a cost-effective and viable solution for use in a variety of settings. A significant contribution to the advancement of sanitization technology and public health is expected with this work.
Collapse
Affiliation(s)
- Leonardo Frizziero
- Alma Mater Studiorum – University of Bologna, viale Risorgimento 2, 40136, Bologna, Italy
| | - Giampiero Donnici
- Alma Mater Studiorum – University of Bologna, viale Risorgimento 2, 40136, Bologna, Italy
| | - Giorgia Venditti
- Alma Mater Studiorum – University of Bologna, viale Risorgimento 2, 40136, Bologna, Italy
| | - Marco Freddi
- Alma Mater Studiorum – University of Bologna, viale Risorgimento 2, 40136, Bologna, Italy
| |
Collapse
|
8
|
Corson E, Pendyala B, Patras A, D'Souza D. Inactivation of hepatitis A virus, feline calicivirus, and Tulane virus on Formica coupons using ultraviolet light technologies. Heliyon 2024; 10:e25201. [PMID: 38371995 PMCID: PMC10873656 DOI: 10.1016/j.heliyon.2024.e25201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/04/2023] [Accepted: 01/23/2024] [Indexed: 02/20/2024] Open
Abstract
Contaminated fomites can lead to hepatitis A virus (HAV) and human norovirus (HuNoV) disease outbreaks. Improved decontamination methods that are user-friendly, cost-effective, and waterless are being researched for sustainability. Traditional ultraviolet light (UV-C) technologies though effective for surface decontamination have drawbacks, using mercury lamps, that pose user-safety risk and environmental hazards. Therefore, UV-C light emitting diode (LED) systems are being designed for delivering required antiviral doses. The objective of this research was to determine the ability of UV-C LED (279 nm) systems to inactivate HuNoV surrogates, feline calicivirus (FCV-F9) and Tulane virus (TV), and HAV on Formica coupons in comparison to UV-C (254 nm) systems. FCV-F9 (∼6 log PFU/mL), TV (∼7 log PFU/mL), or HAV (∼6 log PFU/mL) at 100 μL were surface-spread on sterile Formica coupons (3 × 3 cm2), air-dried, and treated for up to 2.5 min with both systems. Each experiment was replicated thrice. Recovered infectious plaque counts were statistically analyzed using mixed model analysis of variance. FCV-F9, TV, and HAV showed D10 values of 23.37 ± 0.91 mJ/cm2, 16.32 ± 3.6 mJ/cm2, and 12.39 ± 0.70 mJ/cm2 using 279 nm UV-C LED, respectively and D10 values of 9.97 ± 2.44 mJ/cm2, 6.83 ± 1.13 mJ/cm2 and 12.40 ± 1.15 mJ/cm2, respectively with 254 nm UV-C. Higher 279 nm UV-C LED doses were required to cause HuNoV surrogate reduction than 254 nm UV-C, except similar doses with both systems were needed for HAV inactivation on Formica surfaces. It remains critical to measure UV intensity of optical sources and optimize exposure times for desired log reduction on surfaces.
Collapse
Affiliation(s)
- E. Corson
- Department of Food Science, 2600 River Drive, University of Tennessee, Knoxville, TN 37996, USA
| | - B. Pendyala
- Department of Food and Animal Sciences, Tennessee State University, Nashville, Tennessee 37209, USA
| | - A. Patras
- Department of Food and Animal Sciences, Tennessee State University, Nashville, Tennessee 37209, USA
| | - D.H. D'Souza
- Department of Food Science, 2600 River Drive, University of Tennessee, Knoxville, TN 37996, USA
| |
Collapse
|
9
|
Chen L, Zhang H, Chang F, Yu H, Lu M, Zhao J, Ma X, Zhou H, Zhou L, Tan J, Wang J, Luo D, Chen M, Yin L. A multicenter study on the effects of different methods of disinfecting medical external-use ultrasound probes. Am J Infect Control 2024; 52:167-175. [PMID: 37295679 DOI: 10.1016/j.ajic.2023.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 06/02/2023] [Accepted: 06/03/2023] [Indexed: 06/12/2023]
Abstract
BACKGROUND Microbial contamination of external-use ultrasound probes is a serious and overlooked issue. We assessed the effects of different methods of disinfecting medical external-use ultrasound probes. METHODS On-site disinfection experiments were conducted at 10 hospitals; the tips and sides of external-use ultrasound probes were sampled before and after disinfection, and 3 disinfection methods were assessed (use of a new ultraviolet [UV] ultrasound probe disinfector, wiping with ordinary paper towels or cleaning with disinfectant wipes). RESULTS For the new UV probe disinfector, the median microbial death rates for the tips and sides of the external-use ultrasound probe were 93.67% and 97.50%, respectively, which were higher than those for wiping with paper towels and cleaning with disinfectant wipes (12.50% and 10.00% and 20.00% and 21.42%, respectively); the rates of microorganisms exceeding the standard were 15.0% and 13.3%, respectively, which were lower than those for wiping with paper towels and cleaning with disinfectant wipes (53.3% and 60.0% and 46.7% and 38.3%, respectively). The death rates of different species of microorganisms were high, ranging from 87.5% to 100%. CONCLUSIONS The new UV ultrasound probe disinfector significantly reduced the risk of potential nosocomial infections according to the low microbial death rate for conventional disinfection methods.
Collapse
Affiliation(s)
- Lingling Chen
- Department of Cardiovascular Ultrasound and Non-invasive Cardiology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu, Sichuan, China; Ultrasound in Cardiac Electrophysiology and Biomechanics Key Laboratory of Sichuan Province, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China; Ultrasound Medical Quality Control Center of Sichuan Province, Chengdu, Sichuan, China
| | - Hongmei Zhang
- Department of Cardiovascular Ultrasound and Non-invasive Cardiology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu, Sichuan, China; Ultrasound in Cardiac Electrophysiology and Biomechanics Key Laboratory of Sichuan Province, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China; Ultrasound Medical Quality Control Center of Sichuan Province, Chengdu, Sichuan, China
| | - Fan Chang
- Department of Clinical Laboratory Medicine, Sichuan Academy of Medical Sciences & Sichuan Province People's Hospital, Chengdu, Sichuan, China
| | - Hua Yu
- Department of Clinical Laboratory Medicine, Sichuan Academy of Medical Sciences & Sichuan Province People's Hospital, Chengdu, Sichuan, China
| | - Man Lu
- Department of Ultrasound, Sichuan Cancer Hospital, Chengdu, Sichuan, China
| | - Jing Zhao
- Department of Ultrasound, Sichuan Provincial Maternity and Child Health Care Hospital, Chengdu, Sichuan, China
| | - Xiaojuan Ma
- Department of Ultrasound, Chengdu First People's Hospital, Chengdu, Sichuan, China
| | - Hong Zhou
- Department of Ultrasound, Chengdu Third People's Hospital, Chengdu, Sichuan, China
| | - Liuying Zhou
- Department of Ultrasound, Chengdu Women's and Children's Central Hospital, Chengdu, Sichuan, China
| | - Jing Tan
- Department of Ultrasound, the People's Hospital of Wenjiang District, Chengdu, Sichuan, China
| | - Jingyu Wang
- Department of Ultrasound, the First People's Hospital of Longquanyi District, Chengdu, Sichuan, China
| | - Dingqiang Luo
- Department of Ultrasound, Sichuan Tianfu New Area People's Hospital, Chengdu, Sichuan, China
| | - Min Chen
- Department of Ultrasound, Sichuan Modern Hospital, Chengdu, Sichuan, China
| | - Lixue Yin
- Department of Cardiovascular Ultrasound and Non-invasive Cardiology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu, Sichuan, China; Ultrasound in Cardiac Electrophysiology and Biomechanics Key Laboratory of Sichuan Province, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China; Ultrasound Medical Quality Control Center of Sichuan Province, Chengdu, Sichuan, China.
| |
Collapse
|
10
|
Pertegal V, Riquelme E, Lozano-Serra J, Cañizares P, Rodrigo MA, Sáez C, Lacasa E. Cleaning technologies integrated in duct flows for the inactivation of pathogenic microorganisms in indoor environments: A critical review of recent innovations and future challenges. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 345:118798. [PMID: 37591101 DOI: 10.1016/j.jenvman.2023.118798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/02/2023] [Accepted: 08/09/2023] [Indexed: 08/19/2023]
Abstract
Pathogenic microorganisms are a major concern in indoor environments, particularly in sensitive facilities such as hospitals, due to their potential to cause nosocomial infections. This study evaluates the concentration of airborne bacteria and fungi in the University Hospital Complex of Albacete (Spain), comparing the results with recent literature. Staphylococcus is identified as the most prevalent bacterial genus with a percentage distribution of 35%, while Aspergillus represents the dominant fungal genus at 34%. The lack of high Technology Readiness Levels (TRL 6, TRL 7) for effective indoor air purification requires research efforts to bridge this knowledge gap. A screening of disinfection technologies for pathogenic airborne microorganisms such as bacteria and fungi is conducted. The integration of filtration, irradiation or and (electro)chemical gas treatment systems in duct flows is discussed to enhance the design of the air-conditioning systems for indoor air purification. Concerns over microbial growth have led to recent studies on coating commercial fibrous air filters with antimicrobial particles (silver nanoparticles, iron oxide nanowires) and polymeric materials (polyaniline, polyvinylidene fluoride). Promising alternatives to traditional short-wave UV-C energy for disinfection include LED and Far-UVC irradiation systems. Additionally, research explores the use of TiO2 and TiO2 doped with metals (Ag, Cu, Pt) in filters with photocatalytic properties, enabling the utilization of visible or solar light. Hybrid photocatalysis, combining TiO2 with polymers, carbon nanomaterials, or MXene nanomaterials, enhances the photocatalytic process. Chemical treatment systems such as aerosolization of biocidal agents (benzalkonium chloride, hydrogen peroxide, chlorine dioxide or ozone) with their possible combination with other technologies such as adsorption, filtration or photocatalysis, are also tested for gas disinfection. However, the limited number of studies on the use of electrochemical technology poses a challenge for further investigation into gas-phase oxidant generation, without the formation of harmful by-products, to raise its TRL for effectively inactivating airborne microorganisms in indoor environments.
Collapse
Affiliation(s)
- Víctor Pertegal
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario s/n, 02071, Albacete, Spain
| | - Eva Riquelme
- Clinical Parasitology and Microbiology Area. University Hospital Complex of Albacete, C/ Hermanos Falcó 37, 02006, Albacete, Spain
| | - Julia Lozano-Serra
- Clinical Parasitology and Microbiology Area. University Hospital Complex of Albacete, C/ Hermanos Falcó 37, 02006, Albacete, Spain
| | - Pablo Cañizares
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Manuel A Rodrigo
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Cristina Sáez
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Engracia Lacasa
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario s/n, 02071, Albacete, Spain.
| |
Collapse
|
11
|
Guo L, Zhao P, Jia Y, Wang Z, Chen M, Zhang H, Liu D, Zhang Y, Wang X, Rong M. Inactivation of airborne pathogenic microorganisms by plasma-activated nebulized mist. JOURNAL OF HAZARDOUS MATERIALS 2023; 459:132072. [PMID: 37480605 DOI: 10.1016/j.jhazmat.2023.132072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 06/21/2023] [Accepted: 07/14/2023] [Indexed: 07/24/2023]
Abstract
The airborne microorganisms in the aerosols are one main transmission way of pathogenic microorganisms and therefore inactivation of microorganisms in aerosols could effectively prevent the transmission of pathogenic microorganisms to control epidemics. The mist nebulized by plasma-activated air could effectively inactivate bacteria and could be developed for the sterilization of microorganisms in aerosols. In this study, the plasma-activated nebulized mist (PANM) was applied for the inactivation of microorganisms in aerosols and efficiently inactivated the bacteria, yeast, and viruses in aerosols after 2-min treatment. The PANM treatment caused morphologic changes and damage to the bacteria cells in aerosols. The PANM could also inactivate the microorganisms attached to the surface of the treatment chamber and the bacteria attached to the skin of mice within 6-min treatment. The biosafety assays demonstrated that the PANM treatment exhibited no effects on the behavior, hematological and serum biochemical parameters of blood, and organs from the mice. This study would supply an efficient, broad-spectrum, and safe aerosol sterilization strategy based on plasma technology to prevent the transmission of airborne microorganisms.
Collapse
Affiliation(s)
- Li Guo
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Pengyu Zhao
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Yikang Jia
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Zifeng Wang
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Min Chen
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Hao Zhang
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Dingxin Liu
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China.
| | - Yong Zhang
- State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Xiaohua Wang
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Mingzhe Rong
- State Key Laboratory of Electrical Insulation and Power Equipment, Center for Plasma Biomedicine, Xi'an Jiaotong University, Xi'an 710049, PR China
| |
Collapse
|
12
|
Zamudio Díaz DF, Klein AL, Guttmann M, Zwicker P, Busch L, Kröger M, Klose H, Rohn S, Schleusener J, Meinke MC. Skin optical properties from 200 to 300 nm support far UV-C skin-safety in vivo. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2023; 247:112784. [PMID: 37690371 DOI: 10.1016/j.jphotobiol.2023.112784] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 08/07/2023] [Accepted: 09/01/2023] [Indexed: 09/12/2023]
Abstract
The growing threat of multi-drug resistant pathogens and airborne microbial diseases has highlighted the need to improve or develop novel disinfection methods for clinical environments. Conventional ultraviolet C (UV-C) lamps effectively inactivate microorganisms but are harmful to human skin and eyes upon exposure. The use of new 233 nm far UV-C LEDs as an antiseptic can overcome those limitations. In this research, the light penetration into the skin was elucidated for the UV-C region (<300 nm) by measuring the scattering and absorption of skin layers and inverse Monte Carlo simulation, and further confirmed by the first clinical pilot trial in which healthy volunteers were irradiated with a dose of 60 mJ/cm2 at 233 nm. The radiation is strongly absorbed in the stratum corneum, resulting in minimal skin damage without inducing inflammatory responses. The results suggest that 233 nm far UV-C light emitting diodes (LEDs) could effectively inactivate microorganisms, while being safe and soft for the skin.
Collapse
Affiliation(s)
- Daniela F Zamudio Díaz
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany; Technische Universität Berlin, Institute of Food Technology and Food Chemistry, Gustav-Meyer-Allee 25, 13355 Berlin, Germany
| | - Anna Lena Klein
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany
| | - Martin Guttmann
- Ferdinand-Braun-Institut (FBH), Gustav-Kirchhoff-Str. 4, 12489 Berlin, Germany
| | - Paula Zwicker
- University Medicine Greifswald, Institute of Hygiene and Environmental Medicine, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany
| | - Loris Busch
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany
| | - Marius Kröger
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany
| | - Holger Klose
- artMED Private Practice for Plastic and Aesthetic Surgery, Friedrichstraße 61, 10117 Berlin, Germany
| | - Sascha Rohn
- Technische Universität Berlin, Institute of Food Technology and Food Chemistry, Gustav-Meyer-Allee 25, 13355 Berlin, Germany
| | - Johannes Schleusener
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany
| | - Martina C Meinke
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Center of Experimental and Applied Cutaneous Physiology, Department of Dermatology, Venereology and Allergology, Charitéplatz 1, 10117 Berlin, Germany.
| |
Collapse
|
13
|
Yong SS, Lee JI, Kang DH. Bacterial composition of refrigerators in households and inactivation of airborne Staphylococcus aureus using a TiO 2-UVLED module in a 512 L aerobiology chamber. Food Microbiol 2023; 114:104274. [PMID: 37290863 DOI: 10.1016/j.fm.2023.104274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/30/2023] [Accepted: 04/01/2023] [Indexed: 06/10/2023]
Abstract
This study aimed to investigate the microbiota in the air and on the surface of a refrigerator and to inactivate aerosolized Staphylococcus aureus using a TiO2-UVLED module. A total of 100 L of the air and 5000 cm2 surfaces in seven household refrigerators were collected using an air sampler and a swab, respectively. Samples were subjected to microbiota analysis as well as quantitative analyses of aerobic or anaerobic bacteria. The level of airborne aerobic bacteria was 4.26 log CFU/vol (100 L), while that of surface aerobic bacteria was 5.27 log CFU/surface (5000 cm2). PCoA based on the Bray-Curtis metric revealed that the bacterial composition differed between samples collected from refrigerators with and without a vegetable drawer. Moreover, pathogenic bacteria containing genera and order from each sample were found, such as Enterobacaterales, Pseudomonas, Staphylococcus, Listeria, and Bacillus. Among them, Staphylococcus aureus was determined to be a core hazardous pathogen in air. Therefore, three S. aureus strains isolated from the air in refrigerators, as well as a reference strain of S. aureus (ATCC 6538P), were inactivated by a TiO2-UVLED module in a 512 L aerobiology chamber. All aerosolized S. aureus were reduced over 1.6 log CFU/vol after treatment with TiO2 under UVA (365 nm) light at 40 J/cm2. These findings suggest that TiO2-UVLED modules have the potential to be used to control airborne bacteria in household refrigerators.
Collapse
Affiliation(s)
- So-Seum Yong
- Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, Research Institute for Agricultural and Life Sciences, Seoul National University, Seoul, 08826, Republic of Korea
| | - Jae-Ik Lee
- Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, Research Institute for Agricultural and Life Sciences, Seoul National University, Seoul, 08826, Republic of Korea
| | - Dong-Hyun Kang
- Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, Research Institute for Agricultural and Life Sciences, Seoul National University, Seoul, 08826, Republic of Korea; Institutes of Green Bio Science & Technology, Seoul National University, Pyeongchang-gun, Gangwon-do, 25354, Republic of Korea.
| |
Collapse
|
14
|
Wang CP, Chan LC, Liao JY. Self-cooling water disinfection reactor with ultraviolet-C light-emitting diodes. ENVIRONMENTAL TECHNOLOGY 2023; 44:3405-3414. [PMID: 35324415 DOI: 10.1080/09593330.2022.2058425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 03/18/2022] [Indexed: 06/14/2023]
Abstract
The use of ultraviolet-C (UV-C) light-emitting diodes (LEDs) as a water sterilization light source poses a serious challenge in heat dissipation. High junction temperatures reduce the radiant power and lifespan of UV-C LEDs. In this study, a novel self-cooling water disinfection reactor was developed to dissipate Joule heat from UV-C LEDs. The advantage of the self-cooling design is that cooling can be achieved without requiring additional power consumption and cooling liquid. The effects of the water flow rate and driving current of UV-C LEDs on the sterilization of Escherichia coli were investigated for a traditional flow-through reactor and a reactor with self-cooling. The experimental results indicated that an increase in driving current resulted in a considerable increase in the LED temperature of the flow-through reactor but only a marginal increase in the LED temperature of the self-cooling reactor. Under a driving current of 150 mA, the LED temperature of the self-cooling reactor was 55.5°C less than that of the flow-through reactor. The time required by the self-cooling reactor to reach the steady state decreased as the water flow rate increased. Under a flow rate of 100 mL/min, the self-cooling reactor reached the steady state within 62 and 70 s when the driving current was 100 and 150 mA, respectively. Moreover, the average irradiance and inactivation values of the self-cooling reactor were up to 16.5% and 26.0% higher than those of the flow-through reactor, respectively.
Collapse
Affiliation(s)
- Chien-Ping Wang
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan
| | - Lo-Chieh Chan
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan
| | - Jun-You Liao
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan
| |
Collapse
|
15
|
Lombini M, Schreiber L, Albertini R, Alessi EM, Attinà P, Bianco A, Cascone E, Colucci ME, Cortecchia F, De Caprio V, Diolaiti E, Fiorini M, Lessio L, Macchi A, Malaguti G, Mongelluzzo G, Pareschi G, Pelizzo MG, Pasquarella C. Solar ultraviolet light collector for germicidal irradiation on the moon. Sci Rep 2023; 13:8326. [PMID: 37221252 PMCID: PMC10204019 DOI: 10.1038/s41598-023-35438-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 05/18/2023] [Indexed: 05/25/2023] Open
Abstract
Prolonged human-crewed missions on the Moon are foreseen as a gateway for Mars and asteroid colonisation in the next decades. Health risks related to long-time permanence in space have been partially investigated. Hazards due to airborne biological contaminants represent a relevant problem in space missions. A possible way to perform pathogens' inactivation is by employing the shortest wavelength range of Solar ultraviolet radiation, the so-called germicidal range. On Earth, it is totally absorbed by the atmosphere and does not reach the surface. In space, such Ultraviolet solar component is present and effective germicidal irradiation for airborne pathogens' inactivation can be achieved inside habitable outposts through a combination of highly reflective internal coating and optimised geometry of the air ducts. The Solar Ultraviolet Light Collector for Germicidal Irradiation on the Moon is a project whose aim is to collect Ultraviolet solar radiation and use it as a source to disinfect the re-circulating air of the human outposts. The most favourable positions where to place these collectors are over the peaks at the Moon's poles, which have the peculiarity of being exposed to solar radiation most of the time. On August 2022, NASA communicated to have identified 13 candidate landing regions near the lunar South Pole for Artemis missions. Another advantage of the Moon is its low inclination to the ecliptic, which maintains the Sun's apparent altitude inside a reduced angular range. For this reason, Ultraviolet solar radiation can be collected through a simplified Sun's tracking collector or even a static collector and used to disinfect the recycled air. Fluid-dynamic and optical simulations have been performed to support the proposed idea. The expected inactivation rates for some airborne pathogens, either common or found on the International Space Station, are reported and compared with the proposed device efficiency. The results show that it is possible to use Ultraviolet solar radiation directly for air disinfection inside the lunar outposts and deliver a healthy living environment to the astronauts.
Collapse
Affiliation(s)
- Matteo Lombini
- Istituto Nazionale di Astrofisica - Osservatorio di Astrofisica e Scienza dello Spazio di Bologna, Bologna, Italy.
| | - Laura Schreiber
- Istituto Nazionale di Astrofisica - Osservatorio di Astrofisica e Scienza dello Spazio di Bologna, Bologna, Italy
| | - Roberto Albertini
- Dipartimento di Medicina e Chirurgia, Università di Parma, Parma, Italy
| | - Elisa Maria Alessi
- Istituto di Matematica Applicata e Tecnologie Informatiche "E. Magenes" - Consiglio Nazionale delle Ricerche, Milan, Italy
| | - Primo Attinà
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Brera, Merate, LC, Italy
| | - Andrea Bianco
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Brera, Merate, LC, Italy
| | - Enrico Cascone
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Capodimonte, Naples, Italy
| | | | - Fausto Cortecchia
- Istituto Nazionale di Astrofisica - Osservatorio di Astrofisica e Scienza dello Spazio di Bologna, Bologna, Italy
| | - Vincenzo De Caprio
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Capodimonte, Naples, Italy
| | - Emiliano Diolaiti
- Istituto Nazionale di Astrofisica - Osservatorio di Astrofisica e Scienza dello Spazio di Bologna, Bologna, Italy
| | - Mauro Fiorini
- Istituto Nazionale di Astrofisica - Istituto di Astrofisica Spaziale e Fisica Cosmica di Milano, Milan, Italy
| | - Luigi Lessio
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Padova, Padua, Italy
| | - Alberto Macchi
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Brera, Merate, LC, Italy
| | - Giuseppe Malaguti
- Istituto Nazionale di Astrofisica - Osservatorio di Astrofisica e Scienza dello Spazio di Bologna, Bologna, Italy
| | - Giuseppe Mongelluzzo
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Capodimonte, Naples, Italy
| | - Giovanni Pareschi
- Istituto Nazionale di Astrofisica - Osservatorio Astronomico di Brera, Merate, LC, Italy
| | - Maria G Pelizzo
- Dipartimento di Ingegneria dell'Informazione, Università di Padova, Padua, Italy
| | | |
Collapse
|
16
|
Vafadar MF, Zhao S. Ultralow threshold surface emitting ultraviolet lasers with semiconductor nanowires. Sci Rep 2023; 13:6633. [PMID: 37095158 PMCID: PMC10126006 DOI: 10.1038/s41598-023-33457-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 04/13/2023] [Indexed: 04/26/2023] Open
Abstract
Surface-emitting (SE) semiconductor lasers have changed our everyday life in various ways such as communication and sensing. Expanding the operation wavelength of SE semiconductor lasers to shorter ultraviolet (UV) wavelength range further broadens the applications to disinfection, medical diagnostics, phototherapy, and so on. Nonetheless, realizing SE lasers in the UV range has remained to be a challenge. Despite of the recent breakthrough in UV SE lasers with aluminum gallium nitride (AlGaN), the electrically injected AlGaN nanowire UV lasers are based on random optical cavities, whereas AlGaN UV vertical-cavity SE lasers (VCSELs) are all through optical pumping and are all with large lasing threshold power densities in the range of several hundred kW/cm2 to MW/cm2. Herein, we report ultralow threshold, SE lasing in the UV spectral range with GaN-based epitaxial nanowire photonic crystals. Lasing at 367 nm is measured, with a threshold of only around 7 kW/cm2 (~ 49 μJ/cm2), a factor of 100× reduction compared to the previously reported conventional AlGaN UV VCSELs at similar lasing wavelengths. This is also the first achievement of nanowire photonic crystal SE lasers in the UV range. Further given the excellent electrical doping that has already been established in III-nitride nanowires, this work offers a viable path for the development of the long-sought-after semiconductor UV SE lasers.
Collapse
Affiliation(s)
- Mohammad Fazel Vafadar
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, QC, H3A 0E9, Canada
| | - Songrui Zhao
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, QC, H3A 0E9, Canada.
| |
Collapse
|
17
|
Tavares RSN, Adamoski D, Girasole A, Lima EN, da Silva Justo-Junior A, Domingues R, Silveira ACC, Marques RE, de Carvalho M, Ambrosio ALB, Leme AFP, Dias SMG. Different biological effects of exposure to far-UVC (222 nm) and near-UVC (254 nm) irradiation. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2023; 243:112713. [PMID: 37086566 DOI: 10.1016/j.jphotobiol.2023.112713] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 02/18/2023] [Accepted: 04/10/2023] [Indexed: 04/24/2023]
Abstract
Ultraviolet C (UVC) light has long been used as a sterilizing agent, primarily through devices that emit at 254 nm. Depending on the dose and duration of exposure, UV 254 nm can cause erythema and photokeratitis and potentially cause skin cancer since it directly modifies nitrogenated nucleic acid bases. Filtered KrCl excimer lamps (emitting mainly at 222 nm) have emerged as safer germicidal tools and have even been proposed as devices to sterilize surgical wounds. All the studies that showed the safety of 222 nm analyzed cell number and viability, erythema generation, epidermal thickening, the formation of genetic lesions such as cyclobutane pyrimidine dimers (CPDs) and pyrimidine-(6-4)-pyrimidone photoproducts (6-4PPs) and cancer-inducing potential. Although nucleic acids can absorb and be modified by both UV 254 nm and UV 222 nm equally, compared to UV 254 nm, UV 222 nm is more intensely absorbed by proteins (especially aromatic side chains), causing photooxidation and cross-linking. Here, in addition to analyzing DNA lesion formation, for the first time, we evaluated changes in the proteome and cellular pathways, reactive oxygen species formation, and metalloproteinase (MMP) levels and activity in full-thickness in vitro reconstructed human skin (RHS) exposed to UV 222 nm. We also performed the longest (40 days) in vivo study of UV 222 nm exposure in the HRS/J mouse model at the occupational threshold limit value (TLV) for indirect exposure (25 mJ/cm2) and evaluated overall skin morphology, cellular pathological alterations, CPD and 6-4PP formation and MMP-9 activity. Our study showed that processes related to reactive oxygen species and inflammatory responses were more altered by UV 254 nm than by UV 222 nm. Our chronic in vivo exposure assay using the TLV confirmed that UV 222 nm causes minor damage to the skin. However, alterations in pathways related to skin regeneration raise concerns about direct exposure to UV 222 nm.
Collapse
Affiliation(s)
- Renata Spagolla Napoleão Tavares
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Douglas Adamoski
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Alessandra Girasole
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Ellen Nogueira Lima
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Amauri da Silva Justo-Junior
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Romênia Domingues
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Ana Clara Caznok Silveira
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Rafael Elias Marques
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Murilo de Carvalho
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil; Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Andre Luis Berteli Ambrosio
- Sao Carlos Institute of Physics (IFSC), University of Sao Paulo (USP), Sao Carlos, Zip Code 13563-1203, SP, Brazil
| | - Adriana Franco Paes Leme
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil
| | - Sandra Martha Gomes Dias
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Zip Code 13083-970, Campinas, Sao Paulo, Brazil.
| |
Collapse
|
18
|
Mehta I, Hsueh HY, Taghipour S, Li W, Saeedi S. UV Disinfection Robots: A Review. ROBOTICS AND AUTONOMOUS SYSTEMS 2023; 161:104332. [PMID: 36514383 PMCID: PMC9731820 DOI: 10.1016/j.robot.2022.104332] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The novel coronavirus (COVID-19) pandemic has completely changed our lives and how we interact with the world. The pandemic has brought about a pressing need to have effective disinfection practices that can be incorporated into daily life. They are needed to limit the spread of infections through surfaces and air, particularly in public settings. Most of the current methods utilize chemical disinfectants, which can be laborious and time-consuming. Ultraviolet (UV) irradiation is a proven and powerful means of disinfection. There has been a rising interest in the implementation of UV disinfection robots by various public institutions, such as hospitals, long-term care homes, airports, and shopping malls. The use of UV-based disinfection robots could make the disinfection process faster and more efficient. The objective of this review is to equip readers with the necessary background on UV disinfection and provide relevant discussion on various aspects of UV robots.
Collapse
|
19
|
Shin S, Dowden B, Doh IJ, Rajwa B, Bae E, Robinson JP. Surface Environment and Energy Density Effects on the Detection and Disinfection of Microorganisms Using a Portable Instrument. SENSORS (BASEL, SWITZERLAND) 2023; 23:2135. [PMID: 36850732 PMCID: PMC9968048 DOI: 10.3390/s23042135] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 02/08/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Real-time detection and disinfection of foodborne pathogens are important for preventing foodborne outbreaks and for maintaining a safe environment for consumers. There are numerous methods for the disinfection of hazardous organisms, including heat treatment, chemical reaction, filtration, and irradiation. This report evaluated a portable instrument to validate its simultaneous detection and disinfection capability in typical laboratory situations. In this challenging study, three gram-negative and two gram-positive microorganisms were used. For the detection of contamination, inoculations of various concentrations were dispensed on three different surface types to estimate the performance for minimum-detectable cell concentration. Inoculations higher than 103~104 CFU/mm2 and 0.15 mm of detectable contaminant size were estimated to generate a sufficient level of fluorescence signal. The evaluation of disinfection efficacy was conducted on three distinct types of surfaces, with the energy density of UVC light (275-nm) ranging from 4.5 to 22.5 mJ/cm2 and the exposure time varying from 1 to 5 s. The study determined the optimal energy dose for each of the microorganisms species. In addition, surface characteristics may also be an important factor that results in different inactivation efficacy. These results demonstrate that the proposed portable device could serve as an in-field detection and disinfection unit in various environments, and provide a more efficient and user-friendly way of performing disinfection on large surface areas.
Collapse
Affiliation(s)
- Sungho Shin
- Department of Basic Medical Sciences, Purdue University, West Lafayette, IN 47907, USA
| | - Brianna Dowden
- Department of Basic Medical Sciences, Purdue University, West Lafayette, IN 47907, USA
| | - Iyll-Joon Doh
- Department of Basic Medical Sciences, Purdue University, West Lafayette, IN 47907, USA
| | - Bartek Rajwa
- Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907, USA
| | - Euiwon Bae
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - J. Paul Robinson
- Department of Basic Medical Sciences, Purdue University, West Lafayette, IN 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
20
|
TiO2-based photocatalyst Generated Reactive Oxygen Species cause cell membrane disruption of Staphylococcus aureus and Escherichia coli O157:H7. Food Microbiol 2023; 109:104119. [DOI: 10.1016/j.fm.2022.104119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 08/16/2022] [Accepted: 08/16/2022] [Indexed: 11/22/2022]
|
21
|
Demeersseman N, Saegeman V, Cossey V, Devriese H, Schuermans A. Shedding a light on ultraviolet-C technologies in the hospital environment. J Hosp Infect 2023; 132:85-92. [PMID: 36565930 PMCID: PMC9769028 DOI: 10.1016/j.jhin.2022.12.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/11/2022] [Accepted: 12/12/2022] [Indexed: 12/24/2022]
Abstract
Ultraviolet (UV)-C light for disinfection has experienced a surge in popularity since the outbreak of COVID-19. Currently, many different UV-C systems, with varied properties that impact disinfection performance, are available on the market. Therefore this review aims to bundle the available information on UV-C disinfection to obtain an overview of its advantages, disadvantages, and performance-influencing parameters. A literature search was performed using the snowball search method in Google Scholar and PubMed with the following keywords: UV-C disinfection, UV-C dose, UV-C light source, UV-C repair mechanism, UV-C photoreactivation, and UV-C disinfection standards. The main parameters of UV-C disinfection are wavelength, dose, relative humidity, and temperature. There is no consensus about their optimal values, but, in general, light at a high dose and a spectrum of wavelengths containing 260 nm is preferred in an environment at room temperature with low relative humidity. This light can be generated by mercury-vapour, light-emitting diode (LED), pulsed-xenon, or excimer lamps. Multiple factors are detrimental to disinfection performance such as shadowing, a rough surface topography, a high level of contamination, repair mechanisms, and the lack of standardization. Also, there are health and safety risks associated with the UV-C technology when used in the proximity of people. UV-C disinfection systems have promising features and the potential to improve in the future. However, clarifications surrounding the different parameters influencing the technologies' effectiveness in hospital environment are needed. Therefore UV-C disinfection should currently be considered for low-level rather than high-level disinfection.
Collapse
Affiliation(s)
- N Demeersseman
- Department of Infection Control and Prevention, University Hospitals Leuven and Catholic University Leuven, Leuven, Belgium
| | - V Saegeman
- Department of Infection Control and Prevention, University Hospitals Leuven and Catholic University Leuven, Leuven, Belgium
| | - V Cossey
- Department of Infection Control and Prevention, University Hospitals Leuven and Catholic University Leuven, Leuven, Belgium
| | - H Devriese
- Department of Prevention and Environment, University Hospitals Leuven and Catholic University Leuven, Leuven, Belgium
| | - A Schuermans
- Department of Infection Control and Prevention, University Hospitals Leuven and Catholic University Leuven, Leuven, Belgium.
| |
Collapse
|
22
|
Ryan CW. Decreased Respiratory-Related Absenteeism among Preschool Students after Installation of Upper Room Germicidal Ultraviolet Light: Analysis of Newly Discovered Historical Data. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:2536. [PMID: 36767899 PMCID: PMC9915224 DOI: 10.3390/ijerph20032536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 01/06/2023] [Accepted: 01/09/2023] [Indexed: 06/18/2023]
Abstract
The COVID-19 pandemic has brought renewed urgency to air disinfection. Upper room germicidal ultraviolet light (GUV) disinfects room air very efficiently. Its effect on practical outcomes in public settings remains unclear, but history may provide some insights. An interrupted time series model was fitted to a newly discovered dataset of attendance records from a preschool between 1941 to 1949, where GUV was installed in December 1945. GUV was associated with a sizable reduction in child absenteeism due to respiratory illnesses of any cause. Odds ratios for the effect ranged from 0.5 to 0.77, depending on the season. In all but high summer, model-predicted absenteeism rates were reduced by between a third and a half by GUV. Wider use of upper room germicidal UV systems in schools and preschools may be worthwhile, to reduce absenteeism due to respiratory illness and the educational, social, and economic consequences that ensue.
Collapse
Affiliation(s)
- Christopher W. Ryan
- Binghamton Clinical Campus, SUNY Upstate Medical University, 48 Corliss Avenue, Johnson City, NY 13790, USA;
- Broome County Health Department, 225 Front Street, Binghamton, NY 13905, USA
| |
Collapse
|
23
|
Lu YH, Wu H, Zhang HH, Li WS, Lai ACK. Synergistic disinfection of aerosolized bacteria and bacteriophage by far-UVC (222-nm) and negative air ions. JOURNAL OF HAZARDOUS MATERIALS 2023; 441:129876. [PMID: 36087531 DOI: 10.1016/j.jhazmat.2022.129876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/22/2022] [Accepted: 08/28/2022] [Indexed: 06/15/2023]
Abstract
Air ionizers and 222-nm krypton-chlorine (KrCl) excilamp have proven to be effective disinfection apparatus for bacteria and viruses with limited health risks. We determined inactivation efficiencies by operating them individually and in combined modules. Gram-positive and gram-negative bacteria, non-enveloped dsDNA virus, and enveloped dsRNA virus were examined in a designed air disinfection system. Our results showed that the bioaerosols were inactivated efficiently by negative ionizers and far-UVC (222-nm), either used individually or in combination. Among which the combined modules of negative ionizers and KrCl excilamp had the best disinfection performance for the bacteria. The aerosolized virus P22 and Phi 6 were more susceptible to 222-nm emitted by KrCl excilamp than negative air ions. Significant greater inactivation of bacterial bioaerosols were identified after treated by combined treatment of negative air ion and far-UVC for 2 minutes (Escherichia coli, 6.25 natural log (ln) reduction; Staphylococcus epidermidis, 3.66 ln reduction), as compared to the mean sum value of inactivation results by respective individual treatment of negative ionizers and KrCl excilamp (Escherichia coli, 4.34 ln; Staphylococcus epidermidis, 1.75 ln), indicating a synergistic inactivation effect. The findings provide important baseline data to support the design and development of safe and high-efficient disinfection systems.
Collapse
Affiliation(s)
- Y H Lu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China
| | - H Wu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China; Department of Biology, Hong Kong Baptist University, Kowloon, Hong Kong China
| | - H H Zhang
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China
| | - W S Li
- School of Public Health, The University of Hong Kong, Pokfulam, Hong Kong China
| | - A C K Lai
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China.
| |
Collapse
|
24
|
Negishi N, Yamano R, Hori T, Koura S, Maekawa Y, Sato T. Development of a high-speed bioaerosol elimination system for treatment of indoor air. BUILDING AND ENVIRONMENT 2023; 227:109800. [PMID: 36407015 PMCID: PMC9651995 DOI: 10.1016/j.buildenv.2022.109800] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 11/07/2022] [Accepted: 11/08/2022] [Indexed: 06/12/2023]
Abstract
We developed a high-speed filterless airflow multistage photocatalytic elbow aerosol removal system for the treatment of bioaerosols such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Human-generated bioaerosols that diffuse into indoor spaces are 1-10 μm in size, and their selective and rapid treatment can reduce the risk of SARS-CoV-2 infection. A high-speed airflow is necessary to treat large volumes of indoor air over a short period. The proposed system can be used to eliminate viruses in aerosols by forcibly depositing aerosols in a high-speed airflow onto a photocatalyst placed inside the system through inertial force and turbulent diffusion. Because the main component of the deposited bioaerosol is water, it evaporates after colliding with the photocatalyst, and the nonvolatile virus remains on the photocatalytic channel wall. The residual virus on the photocatalytic channel wall is mineralized via photocatalytic oxidation with UVA-LED irradiation in the channel. When this system was operated in a 4.5 m3 aerosol chamber, over 99.8% aerosols in the size range of 1-10 μm were removed within 15 min. The system continued delivering such performance with the continuous introduction of aerosols. Because this system exhibits excellent aerosol removal ability at a flow velocity of 5 m/s or higher, it is more suitable than other reactive air purification systems for treating large-volume spaces.
Collapse
Key Words
- AOP, advanced oxidation process
- Bioaerosol
- CFD, computational fluid dynamics
- COVID-19, coronavirus disease 2019
- DES, detached eddy simulation
- HEPA, high-efficiency particulate absorbing
- ISO, International Standard Organization
- Indoor air
- LES, Large eddy simulation
- RANS, Reynolds-averaged Navier–Stokes
- SARS-CoV-2
- SARS-CoV-2, severe acute respiratory syndrome coronavirus 2
- SCDLP, soya casein-digested lecithin polysorbate
- TiO2 photocatalyst
- UV, ultraviolet
- UVA, ultraviolet-A
- UVC, ultraviolet-C
- Windspeed
Collapse
Affiliation(s)
- Nobuaki Negishi
- Environment Management Research Institute, National Institute of Advanced Industrial Science and Technology, 1-16 Onogawa, Tsukuba, 305-8569, Japan
| | - Ryo Yamano
- Department of Applied Chemistry, Chiba Institute of Technology, 2-17-1 Tsudanuma, Narashino, 275-0016, Japan
| | - Tomoko Hori
- Environment Management Research Institute, National Institute of Advanced Industrial Science and Technology, 1-16 Onogawa, Tsukuba, 305-8569, Japan
| | - Setsuko Koura
- Department of Applied Chemistry, Chiba Institute of Technology, 2-17-1 Tsudanuma, Narashino, 275-0016, Japan
| | - Yuji Maekawa
- Kamaishi Electric Machinery Factory Co. Ltd., 9-171-4 Kasshi-cho, Kamaishi, 026-0055, Japan
| | - Taro Sato
- Kamaishi Electric Machinery Factory Co. Ltd., 9-171-4 Kasshi-cho, Kamaishi, 026-0055, Japan
| |
Collapse
|
25
|
Zhang H, Lai ACK. Evaluation of Single-Pass Disinfection Performance of Far-UVC Light on Airborne Microorganisms in Duct Flows. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:17849-17857. [PMID: 36469399 DOI: 10.1021/acs.est.2c04861] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Far-UVC irradiation (222 nm) is considered an emerging and sustainable solution for future infection and pandemic challenges. We examined the disinfection performance of a krypton-chloride lamp, with a quasi-monochromatic UVC peak at 222 nm, for inactivating airborne microorganisms in a full-scale ventilation duct system. Single-pass disinfection efficacy of far-UVC was determined and compared with that of a conventional mercury-type UVC (254 nm) lamp. Four bacteria, Escherichia coli (E. coli), Pseudomonas alcaligenes (P. alcaligenes), Serratia marcescens (S. marcescens), and Staphylococcus epidermidis (S. epidermidis), as well as bacteriophage P22, were tested under UV exposure with different velocities of duct flows. The data revealed that as the air velocity increased from 0.7 to 4 m/s, the far-UVC disinfection efficacies would decrease by 42, 47, 35, 39, and 33% for these five microorganisms, respectively. The inactivation rate constants to far-UVC light were 4.9, 7.5, 3.3, 6.3, and 3.0 cm2/mJ for aerosolized E. coli, P. alcaligenes, S. marcescens, S. epidermidis, and bacteriophage P22, respectively. Far-UVC irradiation showed a comparable disinfection ability on airborne microorganisms compared with the 254 nm UV irradiation. This first study of far-UVC in real duct applications provides a better understanding of the disinfection performance of this solution in bioaerosol inactivation. It offers a valuable database in the sizing and design of excimer lamps for novel portable air purifiers or in-duct disinfection units.
Collapse
Affiliation(s)
- Huihui Zhang
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong00000, China
| | - Alvin C K Lai
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong00000, China
| |
Collapse
|
26
|
Inagaki H, Goto Y, Sugiyama H, Saito A, Okabayashi T, Watanabe K, Fujimoto S. Usefulness of a new DUV-LED device for the control of infection by Escherichia coli, Staphylococcus aureus, mycobacteria and spore-forming bacteria. Front Public Health 2022; 10:1053729. [PMID: 36544797 PMCID: PMC9760979 DOI: 10.3389/fpubh.2022.1053729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 11/15/2022] [Indexed: 12/12/2022] Open
Abstract
Reliable disinfection and sterilization technologies are needed to deal with the various infectious diseases spreading around the world. Furthermore, bacteria that are difficult to eliminate by ordinary disinfection are also a problem in the medical environment. We examined the germicidal effect of a newly developed deep-ultraviolet light-emitting diode (DUV-LED) prototype device (wavelength of 280 ± 5 nm; power of 0.9 to 1.4 mW/cm2) for floor sterilization against Escherichia coli (E. coli), Staphylococcus aureus (S. aureus), Mycobacterium gordonae (M. gordonae), and Bacillus subtilis (B. subtilis). This prototype device is equipped with highly practical DUV-LEDs with a high output efficiency and a long life, and was designed with consideration of the irradiation distance and the angle of the DUV-LEDs to provide a uniform irradiation rate. We found a statistically significant reduction of ≥90% in the infectious titers of both E. coli and S. aureus after irradiation for 2 s. Although acid-fast bacilli and spore-type bacilli are generally thought to be resistant to UV light irradiation compared to general bacteria, the acid-fast bacillus M. gordonae was inactivated after irradiation for 10 s, and spore-type cells of the bacillus B. subtilis were inactivated by ≥90% after irradiation for 30 s. We also found that the effects were cumulative when irradiation was performed at intervals. In the future, the usefulness of this device as an infection control measure will be evaluated in daily medical practice.
Collapse
Affiliation(s)
- Hiroko Inagaki
- M&N Collaboration Research Laboratory, Department of Medical Environment Innovation, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Yoshitaka Goto
- M&N Collaboration Research Laboratory, Department of Medical Environment Innovation, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Hironobu Sugiyama
- M&N Collaboration Research Laboratory, Department of Medical Environment Innovation, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan,Nikkiso Co., Ltd., Tokyo, Japan
| | - Akatsuki Saito
- Department of Veterinary Science, Faculty of Agriculture, University of Miyazaki, Miyazaki, Japan,Center for Animal Disease Control, University of Miyazaki, Miyazaki, Japan
| | - Tamaki Okabayashi
- Department of Veterinary Science, Faculty of Agriculture, University of Miyazaki, Miyazaki, Japan,Center for Animal Disease Control, University of Miyazaki, Miyazaki, Japan
| | | | - Shouichi Fujimoto
- M&N Collaboration Research Laboratory, Department of Medical Environment Innovation, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan,*Correspondence: Shouichi Fujimoto
| |
Collapse
|
27
|
Abkar L, Zimmermann K, Dixit F, Kheyrandish A, Mohseni M. COVID-19 pandemic lesson learned- critical parameters and research needs for UVC inactivation of viral aerosols. JOURNAL OF HAZARDOUS MATERIALS ADVANCES 2022; 8:100183. [PMID: 36619826 PMCID: PMC9553962 DOI: 10.1016/j.hazadv.2022.100183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 09/28/2022] [Accepted: 10/10/2022] [Indexed: 11/28/2022]
Abstract
The COVID-19 pandemic highlighted public awareness of airborne disease transmission in indoor settings and emphasized the need for reliable air disinfection technologies. This increased awareness will carry in the post-pandemic era along with the ever-emerging SARS-CoV variants, necessitating effective and well-defined protocols, methods, and devices for air disinfection. Ultraviolet (UV)-based air disinfection demonstrated promising results in inactivating viral bioaerosols. However, the reported data diversity on the required UVC doses has hindered determining the best UVC practices and led to confusion among the public and regulators. This article reviews available information on critical parameters influencing the efficacy of a UVC air disinfection system and, consequently, the required dose including the system's components as well as operational and environmental factors. There is a consensus in the literature that the interrelation of humidity and air temperature has a significant impact on the UVC susceptibility, which translate to changing the UVC efficacy of commercialized devices in indoor settings under varying conditions. Sampling and aerosolization techniques reported to have major influence on the result interpretation and it is recommended to use several sampling methods simultaneously to generate comparable and conclusive data. We also considered the safety concerns and the potential safe alternative of UVC, far-UVC. Finally, the gaps in each critical parameter and the future research needs of the field are represented. This paper is the first step to consolidating literature towards developing a standard validation protocol for UVC air disinfection devices which is determined as the one of the research needs.
Collapse
Key Words
- Aerosolization of pathogens
- Air sampling methods
- Airborne transmission
- CDC, centre for disease control and prevention (USA)
- CMD, count median diameter
- DNA, deoxyribonucleic acid
- DSB, double strand break
- Far-UVC
- Far-UVC, ultraviolet irradiation in the ‘far’ range of 200–230 nm
- GTC, growth tube collectors
- LED, light emitting diode
- LPUV, low-pressure ultraviolet lamp
- NIOSH, national institute for occupational safety and health
- PBS, phosphate buffered saline
- PRRS, porcine reproductive and respiratory syndrome
- Particle size distribution
- REL, recommended exposure limit
- RH, relative humidity
- RNA, ribonucleic acid
- ROS, reactive oxygen species
- SARS-CoV-2, severe acute respiratory syndrome coronavirus-2
- SSB, single strand break
- Suspending media
- UV, ultraviolet irradiation
- UV-LED, light emitting diode in the ultraviolet range
- UVC, ultraviolet irradiation in the ‘C’, or germicidal, spectrum from 200 to 290 nm
- UVGI, ultraviolet germicidal irradiation
- Viral UVC susceptibility
- dsDNA, double-stranded deoxyribonucleic acid
- ssRNA, single-stranded ribonucleic acid
Collapse
|
28
|
Ong Q, Ronnie Teo J, Dela Cruz J, Wee E, Wee W, Han W. Irradiation of UVC LED at 277 nm inactivates coronaviruses in association to photodegradation of spike protein. Heliyon 2022; 8:e11132. [PMID: 36276725 PMCID: PMC9575548 DOI: 10.1016/j.heliyon.2022.e11132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/15/2022] [Accepted: 10/12/2022] [Indexed: 11/06/2022] Open
Abstract
To interrupt SARS-CoV-2 transmission chains, Ultraviolet-C (UVC) irradiation has emerged as a potential disinfection tool to aid in blocking the spread of coronaviruses. While conventional 254-nm UVC mercury lamps have been used for disinfection purposes, other UVC wavelengths have emerged as attractive alternatives but a direct comparison of these tools is lacking with the inherent mechanistic properties unclear. Our results using human coronaviruses, hCoV-229E and hCoV-OC43, have indicated that 277-nm UVC LED is most effective in viral inactivation, followed by 222-nm far UVC and 254-nm UVC mercury lamp. While UVC mercury lamp is more effective in degrading viral genomic content compared to 277-nm UVC LED, the latter results in a pronounced photo-degradation of spike proteins which potentially contributed to the higher efficacy of coronavirus inactivation. Hence, inactivation of coronaviruses by 277-nm UVC LED irradiation constitutes a more promising method for disinfection.
Collapse
Affiliation(s)
- Qunxiang Ong
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A∗STAR), 11 Biopolis Way, #02-02, Helios, 138667, Singapore,Corresponding author.
| | - J.W. Ronnie Teo
- Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A∗STAR), 2 Fusionopolis Way, #08-04, Innovis, 138634, Singapore
| | - Joshua Dela Cruz
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A∗STAR), 11 Biopolis Way, #02-02, Helios, 138667, Singapore
| | - Elijah Wee
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A∗STAR), 11 Biopolis Way, #02-02, Helios, 138667, Singapore
| | - Winson Wee
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A∗STAR), 11 Biopolis Way, #02-02, Helios, 138667, Singapore
| | - Weiping Han
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A∗STAR), 11 Biopolis Way, #02-02, Helios, 138667, Singapore,Corresponding author.
| |
Collapse
|
29
|
Nunayon SS, Wang M, Zhang HH, Lai ACK. Evaluating the efficacy of a rotating upper-room UVC-LED irradiation device in inactivating aerosolized Escherichia coli under different disinfection ranges, air mixing, and irradiation conditions. JOURNAL OF HAZARDOUS MATERIALS 2022; 440:129791. [PMID: 36027747 DOI: 10.1016/j.jhazmat.2022.129791] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 08/09/2022] [Accepted: 08/15/2022] [Indexed: 06/15/2023]
Abstract
Cost-effective and safe air disinfection methods are urgently needed in various environmental public settings. A novel UVC-based disinfection system was designed and tested to provide a promising solution because of its effective inactivation of indoor bioaerosols at a low cost. UVC light-emitting diodes (UVC-LEDs) were utilized as the irradiation source. This system has the unique feature of rotating the UVC-LEDs to generate a "scanning irradiation" zone. Escherichia coli was aerosolized into an experimental chamber, exposed to UVC-LEDs, and sampled using an impactor. Effects of air mixing (well-mixed vs. poorly-mixed), transmission range (short vs. long), and irradiation mode (stationary vs. rotating) were evaluated. The system performs significantly well under the poorly-mixed condition. The results obtained from the short disinfection range indicate that the rotating UVC was approximately 70.5 % more effective than the stationary UVC for the poorly-mixed case. Further, we evaluated the performance of the long disinfection range under a poorly-mixed situation, and the disinfection efficacy was 84.6 % higher for the rotating irradiation than that of the stationary. About 0.59-1.34 J/m2 UV dose can be used to obtain one-log inactivation of E. coli. In conclusion, the novel rotating upper-room UVC-LED system is effective in reducing indoor pathogen transmission, and our findings are highly significant to a growing field where LEDs are applied for disinfection.
Collapse
Affiliation(s)
- Sunday S Nunayon
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China; Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| | - Minghao Wang
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Hui H Zhang
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Alvin C K Lai
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China.
| |
Collapse
|
30
|
Optimized parameters for effective SARS-CoV-2 inactivation using UVC-LED at 275 nm. Sci Rep 2022; 12:16664. [PMID: 36198702 PMCID: PMC9534465 DOI: 10.1038/s41598-022-20813-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 09/19/2022] [Indexed: 11/08/2022] Open
Abstract
The spread of SARS-CoV-2 infections and the severity of the coronavirus disease of 2019 (COVID-19) pandemic have resulted in the rapid development of medications, vaccines, and countermeasures to reduce viral transmission. Although new treatment strategies for preventing SARS-CoV-2 infection are available, viral mutations remain a serious threat to the healthcare community. Hence, medical devices equipped with virus-eradication features are needed to prevent viral transmission. UV-LEDs are gaining popularity in the medical field, utilizing the most germicidal UVC spectrum, which acts through photoproduct formation. Herein, we developed a portable and rechargeable medical device that can disinfect SARS-CoV-2 in less than 10 s by 99.9%, lasting 6 h. Using this device, we investigated the antiviral effect of UVC-LED (275 nm) against SARS-CoV-2 as a function of irradiation distance and exposure time. Irradiation distance of 10-20 cm, < 10 s exposure time, and UV doses of > 10 mJ/cm2 were determined optimal for SARS-CoV-2 elimination (≥ 99.99% viral reduction). The UVC-LED systems have advantages such as fast-stabilizing intensity and insensitivity to temperature, and may contribute to developing medical devices capable of containing SARS-CoV-2 infection. By demonstrating SARS-CoV-2 inactivation with very short-term UVC-LED irradiation, our study may suggest guidelines for securing a safer medical environment.
Collapse
|
31
|
Xia T, Guo K, Pan Y, An Y, Chen C. Temporal and spatial far-ultraviolet disinfection of exhaled bioaerosols in a mechanically ventilated space. JOURNAL OF HAZARDOUS MATERIALS 2022; 436:129241. [PMID: 35739760 DOI: 10.1016/j.jhazmat.2022.129241] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 05/18/2022] [Accepted: 05/24/2022] [Indexed: 06/15/2023]
Abstract
Far-UVC with a peak wavelength of 222 nm can potentially be used to inactivate exhaled bioaerosols in an efficient and safe manner. Therefore, this study aimed to experimentally explore the effectiveness of a 222 nm far-UVC light for inactivating bioaerosols, represented by E. coli, exhaled from a manikin in a chamber with mechanical ventilation. The spatial irradiance distribution from the far-UVC light was measured. The susceptibility constant (z-value) for E. coli under the far-UVC light was experimentally obtained. The temporal and spatial concentrations of the bioaerosols exhaled from the manikin were measured under three typical ventilation rates (4, 10, and 36 ACH). According to the results, when the far-UVC light was turned on, the bioaerosol concentrations were lower than those without the far-UVC light under all three ventilation rates, suggesting that far-UVC light can effectively disinfect E. coli under mechanical ventilation. However, the disinfection efficiency of the far-UVC light decreased as the ventilation rate increased, which indicated that the far-UVC light played a more important role in bioaerosol removal under a lower ventilation rate. In general, the results supported the feasibility of using 222 nm far-UVC light for disinfection of exhaled bioaerosols in mechanically ventilated spaces to reduce infection risks.
Collapse
Affiliation(s)
- Tongling Xia
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin N.T. 999077, Hong Kong SAR, China; Breakthrough Technology Center, Midea Building Technologies, Foshan 528000, China
| | - Kangqi Guo
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin N.T. 999077, Hong Kong SAR, China
| | - Yue Pan
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin N.T. 999077, Hong Kong SAR, China
| | - Yuting An
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin N.T. 999077, Hong Kong SAR, China
| | - Chun Chen
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin N.T. 999077, Hong Kong SAR, China; Shenzhen Research Institute, The Chinese University of Hong Kong, Shenzhen 518057, China.
| |
Collapse
|
32
|
Ong Q, Wee W, Dela Cruz J, Teo JWR, Han W. 222-Nanometer Far-UVC Exposure Results in DNA Damage and Transcriptional Changes to Mammalian Cells. Int J Mol Sci 2022; 23:ijms23169112. [PMID: 36012379 PMCID: PMC9408858 DOI: 10.3390/ijms23169112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 11/16/2022] Open
Abstract
Ultraviolet (UV) germicidal tools have recently gained attention as a disinfection strategy against the COVID-19 pandemic, but the safety profile arising from their exposure has been controversial and impeded larger-scale implementation. We compare the emerging 222-nanometer far UVC and 277-nanometer UVC LED disinfection modules with the traditional UVC mercury lamp emitting at 254 nm to understand their effects on human retinal cell line ARPE-19 and HEK-A keratinocytes. Cells illuminated with 222-nanometer far UVC survived, while those treated with 254-nanometer and 277-nanometer wavelengths underwent apoptosis via the JNK/ATF2 pathway. However, cells exposed to 222-nanometer far UVC presented the highest degree of DNA damage as evidenced by yH2AX staining. Globally, these cells displayed transcriptional changes in cell-cycle and senescence pathways. Thus, the introduction of 222-nanometer far UVC lamps for disinfection purposes should be carefully considered and designed with the inherent dangers involved.
Collapse
Affiliation(s)
- Qunxiang Ong
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02, Helios, Singapore 138667, Singapore
- Correspondence: (Q.O.); (W.H.)
| | - Winson Wee
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02, Helios, Singapore 138667, Singapore
| | - Joshua Dela Cruz
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02, Helios, Singapore 138667, Singapore
| | - Jin Wah Ronnie Teo
- Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, #08-04, Innovis, Singapore 138634, Singapore
| | - Weiping Han
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR), 11 Biopolis Way, #02-02, Helios, Singapore 138667, Singapore
- Correspondence: (Q.O.); (W.H.)
| |
Collapse
|
33
|
Bang JI, Kim JH, Choi A, Sung M. The Wavelength-Based Inactivation Effects of a Light-Emitting Diode Module on Indoor Microorganisms. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:9659. [PMID: 35955018 PMCID: PMC9368635 DOI: 10.3390/ijerph19159659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/03/2022] [Accepted: 08/03/2022] [Indexed: 06/15/2023]
Abstract
With the increased incidence of infectious disease outbreaks in recent years such as the COVID-19 pandemic, related research is being conducted on the need to prevent their spread; it is also necessary to develop more general physical-chemical control methods to manage them. Consequently, research has been carried out on light-emitting diodes (LEDs) as an effective means of light sterilization. In this study, the sterilization effects on four types of representative bacteria and mold that occur indoors, Bacillus subtilis, Escherichia coli, Penicillium chrysogenum, and Cladosporium cladosporidides, were confirmed using LED modules (with wavelengths of 275, 370, 385, and 405 nm). Additionally, power consumption was compared by calculating the time required for 99.9% sterilization of each microorganism. The results showed that the sterilization effect was high, in the order 275, 370, 385, and 405 nm. The sterilization effects at 385 and 405 nm were observed to be similar. Furthermore, when comparing the power consumption required for 99.9% sterilization of each microorganism, the 275 nm LED module required significantly less power than those of other wavelengths. However, at 405 nm, the power consumption required for 99.9% sterilization was less than that at 370 nm; that is, it was more efficient and similar to or less than that at 385 nm. Additionally, because 405 nm can be applied as general lighting, it was considered to have wider applicability and utility compared with UV wavelengths. Consequently, it should be possible to respond to infectious diseases in the environment using LEDs with visible light wavelengths.
Collapse
Affiliation(s)
- Jong-Il Bang
- Department of Architectural Engineering, Sejong University, 209 Neungdong-Ro, Gwangjin-Gu, Seoul 05006, Korea
| | - Ji-Hi Kim
- Specialization Strategy Technology Department, EAN Technology Co., Ltd., EAN Institute of Sustainable Technology, 77-gil Teheran-Ro, Gangnam-Gu, Seoul 06159, Korea
| | - Anseop Choi
- Department of Architectural Engineering, Sejong University, 209 Neungdong-Ro, Gwangjin-Gu, Seoul 05006, Korea
| | - Minki Sung
- Department of Architectural Engineering, Sejong University, 209 Neungdong-Ro, Gwangjin-Gu, Seoul 05006, Korea
| |
Collapse
|
34
|
Zhang L, Guo Y, Chang X, Yao Z, Wei X, Feng Z, Zhang D, Zhou Q, Wang X, Luo H. In-duct grating-like dielectric barrier discharge system for air disinfection. JOURNAL OF HAZARDOUS MATERIALS 2022; 435:129075. [PMID: 35650753 PMCID: PMC9072810 DOI: 10.1016/j.jhazmat.2022.129075] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/01/2022] [Accepted: 05/02/2022] [Indexed: 05/04/2023]
Abstract
In the context of spreading Coronavirus disease 2019 (COVID-19), the combination of heating, ventilation, and air-conditioning (HVAC) system with air disinfection device is an effective way to reduce transmissible infections. Atmospheric-pressure non-equilibrium plasma is an emerging technique for fast pathogen aerosol abatement. In this work, in-duct disinfectors based on grating-like dielectric barrier discharge (DBD) plasmas with varied electrode arrangements were established and evaluated. The highest airborne bacterial inactivation efficiency was achieved by 'vertical' structure, namely when aerosol was in direct contact with the discharge region, at a given discharge power. For all reactors, the efficiency was linearly correlated to the discharge power (R2 =0.929-0.994). The effects of environmental factors were examined. Decreased airflow rates boosted the efficiency, which reached 99.8% at the velocity of 0.5 m/s with an aerosol residence time of ~3.6 ms. Increasing humidity (relative humidity (RH)=20-60%) contributed to inactivation efficacy, while high humidity (RH=70%-90%) led to a saturated efficiency, possibly due to the disruption of discharge uniformity. As suggested by the plasma effluent treatment and scavenger experiments, gaseous short-lived chemical species or charged particles were concluded as the major agents accounting for bacterial inactivation. This research provides new hints for air disinfection by DBD plasmas.
Collapse
Affiliation(s)
- Liyang Zhang
- Department of Electrical Engineering, Tsinghua University, Beijing, China
| | - Yuntao Guo
- Department of Electrical Engineering, Tsinghua University, Beijing, China.
| | - Xuanyu Chang
- Marine Design and Research Institute of China (MARIC), Shanghai, China
| | - Zenghui Yao
- School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China
| | - Xiaodong Wei
- Marine Design and Research Institute of China (MARIC), Shanghai, China
| | - Zihao Feng
- Department of Electrical Engineering, Tsinghua University, Beijing, China
| | - Dongheyu Zhang
- Department of Electrical Engineering, Tsinghua University, Beijing, China
| | - Qun Zhou
- Department of Chemistry, Tsinghua University, Beijing, China
| | - Xinxin Wang
- Department of Electrical Engineering, Tsinghua University, Beijing, China
| | - Haiyun Luo
- Department of Electrical Engineering, Tsinghua University, Beijing, China.
| |
Collapse
|
35
|
Perception of Professionals from Different Healthcare Units Regarding the Use of Spray Technology for the Instantaneous Decontamination of Personal Protective Equipment during the Coronavirus Disease Pandemic: A Short Analysis. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Within the context of the coronavirus disease (COVID-19) pandemic, different disinfection technologies have been developed to efficiently exercise microbial control, especially to minimize the potential risks that are associated with transmission and infection among healthcare professionals. Thus, the aim of this work was to evaluate the perception of professionals regarding the use of a new technology (chamber) for the instantaneous decontamination of personal protective equipment before the doffing stage. This was a cross-sectional descriptive study where the study data were obtained by using a questionnaire with qualitative questions. In total, 245 professionals participated in the study in three hospitals. Healthcare professionals represented 72.24% (n = 177) of the investigated sample. Approximately 69% of the professionals considered the disinfection chamber as a safe technology, and 75.10% considered it as an important and effective protective barrier for healthcare professionals in view of its application before the doffing process. The results found in this study demonstrate that the use of spray technology in the stage prior to the doffing process is acceptable to professionals, and that it can be an important tool for ensuring the additional protection of the professionals who work directly with patients who are diagnosed with COVID-19.
Collapse
|
36
|
UV 254 nm is more efficient than UV 222 nm in inactivating SARS-CoV-2 present in human saliva. Photodiagnosis Photodyn Ther 2022; 39:103015. [PMID: 35843562 PMCID: PMC9281457 DOI: 10.1016/j.pdpdt.2022.103015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 07/10/2022] [Accepted: 07/11/2022] [Indexed: 11/20/2022]
Abstract
Ultraviolet (UV) light can inactivate SARS-CoV-2. However, the practicality of UV light is limited by the carcinogenic potential of mercury vapor-based UV lamps. Recent advances in the development of krypton chlorine (KrCl) excimer lamps hold promise, as these emit a shorter peak wavelength (222 nm), which is highly absorbed by the skin's stratum corneum and can filter out higher wavelengths. In this sense, UV 222 nm irradiation for the inactivation of virus particles in the air and surfaces is a potentially safer option as a germicidal technology. However, these same physical properties make it harder to reach microbes present in complex solutions, such as saliva, a critical source of SARS-CoV-2 transmission. We provide the first evaluation for using a commercial filtered KrCl excimer light source to inactivate SARS-CoV-2 in saliva spread on a surface. A conventional germicidal lamp (UV 254 nm) was also evaluated under the same condition. Using plaque-forming units (PFU) and Median Tissue Culture Infectious Dose (TCID50) per milliliter we found that 99.99% viral clearance (LD99.99) was obtained with 106.3 mJ/cm2 of UV 222 nm for virus in DMEM and 2417 mJ/cm2 for virus in saliva. Additionally, our results showed that the UV 254 nm had a greater capacity to inactivate the virus in both vehicles. Effective (after discounting light absorption) LD99.99 of UV 222 nm on the virus in saliva was ∼30 times higher than the value obtained with virus in saline solution (PBS), we speculated that saliva might be protecting the virus from surface irradiation in ways other than just by intensity attenuation of UV 222 nm. Due to differences between UV 222/254 nm capacities to interact and be absorbed by molecules in complex solutions, a higher dose of 222 nm will be necessary to reduce viral load in surfaces with contaminated saliva.
Collapse
|
37
|
Samal P, Samal JRK, Gubbins E, Vroemen P, van Blitterswijk C, Truckenmüller R, Giselbrecht S. Polystyrene Pocket Lithography: Sculpting Plastic with Light. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2200687. [PMID: 35358334 DOI: 10.1002/adma.202200687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 03/27/2022] [Indexed: 06/14/2023]
Abstract
Tissue-culture-ware polystyrene is the gold standard for in vitro cell culture. While microengineering techniques can create advanced cell microenvironments in polystyrene, they require specialized equipment and reagents, which hinder their accessibility for most biological researchers. An economical and easily accessible method is developed and validated for fabricating microstructures directly in polystyrene with sizes approaching subcellular dimensions while requiring minimal processing time. The process involves deep ultraviolet irradiation through a shadow mask or ink pattern using inexpensive, handheld devices followed by selective chemical development with common reagents to generate micropatterns with depths/heights between 5 and 10 µm, which can be used to guide cell behavior. The remarkable straightforwardness of the process enables this class of microengineering techniques to be broadly accessible to diverse research communities.
Collapse
Affiliation(s)
- Pinak Samal
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
| | - Jay Rabindra Kumar Samal
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
| | - Eva Gubbins
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
| | - Pascal Vroemen
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
- University Eye Clinic Maastricht UMC+, Maastricht University Medical Centre+, P. Debyelaan 25, Maastricht, 6229 HX, The Netherlands
| | - Clemens van Blitterswijk
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
| | - Roman Truckenmüller
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
| | - Stefan Giselbrecht
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitssingel 40, Maastricht, 6229 ER, The Netherlands
| |
Collapse
|
38
|
Baek KH, Kim SJ, Kim T, Hwang Y, Park JY, Yang JY, Ryoo S, Lee S. Evaluation of zone-disinfection effect of air-passable plasma filter in a novel chamber model. J Hosp Infect 2022; 128:1-7. [PMID: 35788014 DOI: 10.1016/j.jhin.2022.06.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 06/18/2022] [Accepted: 06/19/2022] [Indexed: 10/17/2022]
Abstract
BACKGROUND Disinfection of shared spaces has become essential to minimize the spread of various diseases. An efficient disinfection device that can simultaneously inactivate airborne bacteria and surface adhered bacteria in an enclosed space is required. AIM An air-passable plasma filter (APF) was developed and applied to a chamber model to evaluate the zone-disinfection effect. METHODS The 60 litre chamber consisted of a nebulizer, circulation fans, temperature and humidity monitors, an air sampling port with a sealed gate, airborne bacteria trapping media, and a built-in fan for evaluation. After spraying each bacterial strain (Escherichia coli, Staphylococcus epidermidis, and Mycobacterium smegmatis) as a bioaerosol, airborne and surface-attached bacteria were quantified simultaneously to evaluate the zone-disinfection effect of APF. FINDINGS The operation of APF in the 60 litre chamber showed a complete zone-disinfection effect for E. coli (10 min), S. epidermidis (10 min), and M. smegmatis (60 min) present in the air and on the walls at various locations. The time required to completely disinfect each of the airborne bacteria and surface-attached bacteria within the same space was different. CONCLUSION APF has the potential to exhibit significant germicidal effects on various microorganisms and can be an effective alternative for disinfection of enclosed spaces.
Collapse
Affiliation(s)
- Ki Ho Baek
- Department of Nano-Bio Convergence, Korea Institute of Materials Science, Changwon 51508, Republic of Korea
| | - Sang-Jin Kim
- Department of Nano-Bio Convergence, Korea Institute of Materials Science, Changwon 51508, Republic of Korea
| | - Taeyoon Kim
- Clinical Research Centre, Masan National Tuberculosis Hospital, Changwon 51755, Republic of Korea
| | - Yoohyun Hwang
- Clinical Research Centre, Masan National Tuberculosis Hospital, Changwon 51755, Republic of Korea
| | - Joo Young Park
- Department of Nano-Bio Convergence, Korea Institute of Materials Science, Changwon 51508, Republic of Korea
| | - Jun-Yeong Yang
- Department of Nano-Bio Convergence, Korea Institute of Materials Science, Changwon 51508, Republic of Korea
| | - Sungweon Ryoo
- Clinical Research Centre, Masan National Tuberculosis Hospital, Changwon 51755, Republic of Korea.
| | - Seunghun Lee
- Department of Nano-Bio Convergence, Korea Institute of Materials Science, Changwon 51508, Republic of Korea.
| |
Collapse
|
39
|
Vuerich R, Martinelli V, Vodret S, Bertani I, Carletti T, Zentilin L, Venturi V, Marcello A, Zacchigna S. A new laser device for ultra-rapid and sustainable aerosol sterilization. ENVIRONMENT INTERNATIONAL 2022; 164:107272. [PMID: 35526297 PMCID: PMC9060718 DOI: 10.1016/j.envint.2022.107272] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/27/2022] [Accepted: 04/27/2022] [Indexed: 06/14/2023]
Abstract
The current COVID-19 pandemic has highlighted the importance of aerosol-based transmission of human pathogens; this therefore calls for novel medical devices which are able to sterilize contaminated aerosols. Here we describe a new laser device able to sterilize droplets containing either viruses or bacteria. Using engineered viral particles, we determined the 10,600 nm wavelength as the most efficient and exploitable laser source to be manufactured in a commercial device. Given the lack of existing working models to reproduce a human aerosol containing living microbial particles, we developed a new system mimicking human droplet formation and preserving bacterial and viral viability. This evidenced the efficacy of 10,600 nm laser light to kill two aerosol transmitted human pathogens, Legionella pneumophila and SARS-CoV-2. The minimal exposure time of <15 ms was required for the inactivation of over 99% pathogens in the aerosol; this is a key element in the design of a device that is safe and can be used in preventing inter-individual transmission. This represents a major advantage over existing devices, which mainly aim at either purifying incoming air by filters or sterilizing solid surfaces, which are not the major transmission routes for airborne communicable diseases.
Collapse
Affiliation(s)
- Roman Vuerich
- Cardiovascular Biology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy; Department of Life Sciences, University of Trieste, 34127 Trieste, Italy
| | | | - Simone Vodret
- Cardiovascular Biology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy
| | - Iris Bertani
- Laboratory: Bacteriology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy
| | - Tea Carletti
- Molecular Virology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy
| | - Lorena Zentilin
- Molecular Medicine Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy
| | - Vittorio Venturi
- Laboratory: Bacteriology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy
| | - Alessandro Marcello
- Molecular Virology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy
| | - Serena Zacchigna
- Cardiovascular Biology Laboratory, International Centre for Genetic Engineering and Biotechnology (ICGEB), 34149 Trieste, Italy; Department of Medical, Surgical and Health Sciences, University of Trieste, 34127 Trieste, Italy. https://www.icgeb.org/cardiovascular-biology/
| |
Collapse
|
40
|
Kim DK, Shin M, Kim HS, Kang DH. Inactivation efficacy of combination treatment of blue light-emitting diodes (LEDs) and riboflavin to control E. coli O157:H7 and S. Typhimurium in apple juice. INNOV FOOD SCI EMERG 2022. [DOI: 10.1016/j.ifset.2022.103014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
41
|
Padrão J, Nicolau T, Felgueiras HP, Calçada C, Veiga MI, Osório NS, Martins MS, Dourado N, Taveira-Gomes A, Ferreira F, Zille A. Development of an Ultraviolet-C Irradiation Room in a Public Portuguese Hospital for Safe Re-Utilization of Personal Protective Respirators. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19084854. [PMID: 35457722 PMCID: PMC9026523 DOI: 10.3390/ijerph19084854] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 04/08/2022] [Accepted: 04/14/2022] [Indexed: 02/04/2023]
Abstract
Almost two years have passed since COVID-19 was officially declared a pandemic by the World Health Organization. However, it still holds a tight grasp on the entire human population. Several variants of concern, one after another, have spread throughout the world. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) omicron variant may become the fastest spreading virus in history. Therefore, it is more than evident that the use of personal protective equipment (PPE) will continue to play a pivotal role during the current pandemic. This work depicts an integrative approach attesting to the effectiveness of ultra-violet-C (UV-C) energy density for the sterilization of personal protective equipment, in particular FFP2 respirators used by the health care staff in intensive care units. It is increasingly clear that this approach should not be limited to health care units. Due to the record-breaking spreading rates of SARS-CoV-2, it is apparent that the use of PPE, in particular masks and respirators, will remain a critical tool to mitigate future pandemics. Therefore, similar UV-C disinfecting rooms should be considered for use within institutions and companies and even incorporated within household devices to avoid PPE shortages and, most importantly, to reduce environmental burdens.
Collapse
Affiliation(s)
- Jorge Padrão
- Centre for Textile Science and Technology (2C2T), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal; (T.N.); (H.P.F.); (A.Z.)
- Correspondence:
| | - Talita Nicolau
- Centre for Textile Science and Technology (2C2T), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal; (T.N.); (H.P.F.); (A.Z.)
| | - Helena P. Felgueiras
- Centre for Textile Science and Technology (2C2T), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal; (T.N.); (H.P.F.); (A.Z.)
| | - Carla Calçada
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Campus Gualtar, 4710-057 Braga, Portugal; (C.C.); (M.I.V.); (N.S.O.)
- ICVS/3B’s—PT Government Associate Laboratory, University of Minho, 4806-909 Guimarães, Portugal
| | - Maria Isabel Veiga
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Campus Gualtar, 4710-057 Braga, Portugal; (C.C.); (M.I.V.); (N.S.O.)
- ICVS/3B’s—PT Government Associate Laboratory, University of Minho, 4806-909 Guimarães, Portugal
| | - Nuno S. Osório
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Campus Gualtar, 4710-057 Braga, Portugal; (C.C.); (M.I.V.); (N.S.O.)
- ICVS/3B’s—PT Government Associate Laboratory, University of Minho, 4806-909 Guimarães, Portugal
| | - Marcos S. Martins
- Center for MicroElectroMechanics Systems (CMEMS), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal; (M.S.M.); (N.D.)
- LABBELS—Associate Laboratory, 4800-058 Guimarães, Portugal
| | - Nuno Dourado
- Center for MicroElectroMechanics Systems (CMEMS), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal; (M.S.M.); (N.D.)
- LABBELS—Associate Laboratory, 4800-058 Guimarães, Portugal
| | - António Taveira-Gomes
- Department of Surgery, Pedro Hispano Hospital, Local Health Unit Matosinhos (Public-Private Partnerships), 4464-513 Senhora da Hora, Portugal; (A.T.-G.); (F.F.)
- Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| | - Fernando Ferreira
- Department of Surgery, Pedro Hispano Hospital, Local Health Unit Matosinhos (Public-Private Partnerships), 4464-513 Senhora da Hora, Portugal; (A.T.-G.); (F.F.)
| | - Andrea Zille
- Centre for Textile Science and Technology (2C2T), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal; (T.N.); (H.P.F.); (A.Z.)
| |
Collapse
|
42
|
A Comprehensive Analysis of the UVC LEDs' Applications and Decontamination Capability. MATERIALS 2022; 15:ma15082854. [PMID: 35454546 PMCID: PMC9028096 DOI: 10.3390/ma15082854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 01/27/2023]
Abstract
The application of light-emitting diodes (LEDs) has been gaining popularity over the last decades. LEDs have advantages compared to traditional light sources in terms of lifecycle, robustness, compactness, flexibility, and the absence of non-hazardous material. Combining these advantages with the possibility of emitting Ultraviolet C (UVC) makes LEDs serious candidates for light sources in decontamination systems. Nevertheless, it is unclear if they present better decontamination effectiveness than traditional mercury vapor lamps. Hence, this research uses a systematic literature review (SLR) to enlighten three aspects: (1) UVC LEDs' application according to the field, (2) UVC LEDs' application in terms of different biological indicators, and (3) the decontamination effectiveness of UVC LEDs in comparison to conventional lamps. UVC LEDs have spread across multiple areas, ranging from health applications to wastewater or food decontamination. The UVC LEDs' decontamination effectiveness is as good as mercury vapor lamps. In some cases, LEDs even provide better results than conventional mercury vapor lamps. However, the increase in the targets' complexity (e.g., multilayers or thicker individual layers) may reduce the UVC decontamination efficacy. Therefore, UVC LEDs still require considerable optimization. These findings are stimulating for developing industrial or final users' applications.
Collapse
|
43
|
Sobotka P, Przychodzki M, Uściło K, Woliński TR, Staniszewska M. Effect of Ultraviolet Light C (UV-C) Radiation Generated by Semiconductor Light Sources on Human Beta-Coronaviruses' Inactivation. MATERIALS 2022; 15:ma15062302. [PMID: 35329754 PMCID: PMC8949262 DOI: 10.3390/ma15062302] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/11/2022] [Accepted: 03/14/2022] [Indexed: 11/16/2022]
Abstract
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has completely disrupted people’s lives. All over the world, many restrictions and precautions have been introduced to reduce the spread of coronavirus disease 2019 (COVID-19). Ultraviolet C (UV-C) radiation is widely used to disinfect rooms, surfaces, and medical tools; however, this paper presents novel results obtained for modern UV-C light-emitting diodes (LEDs), examining their effect on inhibiting the multiplication of viruses. The main goal of the work was to investigate how to most effectively use UV-C LEDs to inactivate viruses. We showed that UV-C radiation operating at a 275 nm wavelength is optimal for germicidal effectiveness in a time exposure (25−48 s) study: >3 log-reduction with the Kärber method and >6 log-reduction with UV spectrophotometry were noted. We used real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) to reliably estimate virus infectivity reduction after 275 nm UV-C disinfection. The relative quantification (RQ) of infectious particles detected after 40−48 s distinctly decreased. The irradiated viral RNAs were underexpressed compared to the untreated control virial amplicon (estimated as RQ = 1). In conclusion, this work provides the first experimental data on 275 nm UV-C in the inactivation of human coronavirus OC43 (HoV-OC43), showing the most potent germicidal effect without hazardous effect.
Collapse
Affiliation(s)
- Piotr Sobotka
- Faculty of Physics, Warsaw University of Technology, 00-662 Warsaw, Poland; (M.P.); (T.R.W.)
- Correspondence: (P.S.); (M.S.); Tel.: +48-22-234-7262 (P.S.); +48-606-438-241 (M.S.)
| | - Maciej Przychodzki
- Faculty of Physics, Warsaw University of Technology, 00-662 Warsaw, Poland; (M.P.); (T.R.W.)
| | - Konrad Uściło
- Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, 02-822 Warsaw, Poland;
| | - Tomasz R. Woliński
- Faculty of Physics, Warsaw University of Technology, 00-662 Warsaw, Poland; (M.P.); (T.R.W.)
| | - Monika Staniszewska
- Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, 02-822 Warsaw, Poland;
- Correspondence: (P.S.); (M.S.); Tel.: +48-22-234-7262 (P.S.); +48-606-438-241 (M.S.)
| |
Collapse
|
44
|
Vlaskin MS. Review of air disinfection approaches and proposal for thermal inactivation of airborne viruses as a life-style and an instrument to fight pandemics. APPLIED THERMAL ENGINEERING 2022; 202:117855. [PMID: 34867067 PMCID: PMC8628600 DOI: 10.1016/j.applthermaleng.2021.117855] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 10/20/2021] [Accepted: 11/24/2021] [Indexed: 05/02/2023]
Abstract
COVID-19 (Coronavirus Disease 2019) pandemic highlighted the importance of air biosecurity because SARS-CoV-2 is mainly transmitted from person to person via airborne droplets. Preventing infectious droplets from entering the body is one of the best ways to protect against infection. This paper reviews the transmission patterns of airborne pathogens and air disinfection methods. A particular emphasis is put on studies devoted to the thermal inactivation of viruses. These reviews reveal that air heat treatment has not been seriously considered as a possible air disinfection approach. Simple calculations show that the energy input required for thermal disinfection of human's air daily consumption is almost the same as for daily water consumption (by heat treatment from room temperature to 100 °C). Moreover, it is possible to organize a continuous heat recovery from the air already heated during disinfection to the inlet air, thus significantly increasing the energy efficiency. Therefore, I propose a solution for the thermal inactivation of airborne pathogens based on air heating and its subsequent cooling in a heat exchanger with heat recovery. Such a solution could be used to create mobile personal and stationary indoor air disinfectors, as well as heating, ventilation, and air conditioning systems. Thermal disinfection of air to breathe might one day be part of people's daily life like thermal disinfection of drinking water. Aside from limiting infectious disease transmission, thermal inactivation might be the basis for developing inhaled vaccines using thermally inactivated whole pathogens.
Collapse
Affiliation(s)
- Mikhail S Vlaskin
- Joint Institute for High Temperatures of the Russian Academy of Sciences, 13/2 Izhorskaya St, Moscow 125412, Russia
| |
Collapse
|
45
|
do Prado-Silva L, Brancini GT, Braga GÚ, Liao X, Ding T, Sant’Ana AS. Antimicrobial photodynamic treatment (aPDT) as an innovative technology to control spoilage and pathogenic microorganisms in agri-food products: An updated review. Food Control 2022. [DOI: 10.1016/j.foodcont.2021.108527] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
46
|
Besegato JF, de Melo PBG, Tamae PE, Alves APAR, Rondón LF, Leanse LG, Dos Anjos C, Casarin HH, Chinelatti MA, Faria G, Dai T, Bagnato VS, Rastelli ANDS. How can biophotonics help dentistry to avoid or minimize cross infection by SARS-CoV-2? Photodiagnosis Photodyn Ther 2021; 37:102682. [PMID: 34910994 PMCID: PMC8666148 DOI: 10.1016/j.pdpdt.2021.102682] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 09/30/2021] [Accepted: 12/10/2021] [Indexed: 12/23/2022]
Abstract
Biophotonics is defined as the combination of biology and photonics (the physical science of the light). It is a general term for all techniques that deal with the interaction between biological tissues/cells and photons (light). Biophotonics offers a great variety of techniques that can facilitate the early detection of diseases and promote innovative theragnostic approaches. As the COVID-19 infection can be transmitted due to the face-to-face communication, droplets and aerosol inhalation and the exposure to saliva, blood, and other body fluids, as well as the handling of sharp instruments, dental practices are at increased risk of infection. In this paper, a literature review was performed to explore the application of Biophotonics approaches in Dentistry focusing on the COVID-19 pandemic and how they can contribute to avoid or minimize the risks of infection in a dental setting. For this, search-related papers were retrieved from PubMED, Scielo, Google Schoolar, and American Dental Association and Centers for Disease Control and Prevention databases. The body of evidence currently available showed that Biophotonics approaches can reduce microorganism load, decontaminate surfaces, air, tissues, and minimize the generation of aerosol and virus spreading by minimally invasive, time-saving, and alternative techniques in general. However, each clinical situation must be individually evaluated regarding the benefits and drawbacks of these approaches, but always pursuing less-invasive and less aerosol-generating procedures, especially during the COVID-19 pandemic.
Collapse
Affiliation(s)
- João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil
| | - Priscila Borges Gobbo de Melo
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil
| | - Patrícia Eriko Tamae
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil
| | - Ana Paula Aparecida Raimundo Alves
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil
| | - Luis Felipe Rondón
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil
| | - Leon G Leanse
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, University of Harvard, Boston, MA 02114, USA.
| | - Carolina Dos Anjos
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, University of Harvard, Boston, MA 02114, USA.
| | - Heitor Hussni Casarin
- Dentistry School, Central Paulista University Center - UNICEP, São Carlos 13563-470, SP, Brazil
| | | | - Gisele Faria
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil.
| | - Tianhong Dai
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, University of Harvard, Boston, MA 02114, USA.
| | | | - Alessandra Nara de Souza Rastelli
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Araraquara 14801-903, SP, Brazil.
| |
Collapse
|
47
|
Ahmadi Y, Bhardwaj N, Kim KH, Kumar S. Recent advances in photocatalytic removal of airborne pathogens in air. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 794:148477. [PMID: 34198079 DOI: 10.1016/j.scitotenv.2021.148477] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 05/31/2021] [Accepted: 06/11/2021] [Indexed: 06/13/2023]
Abstract
The abatement of airborne pathogens such as bacteria, viruses, and fungi has become an important goal of air-quality management. Efficient and effective treatment techniques such as photocatalysis are essential for disinfection of airborne microorganisms. This review focuses on recent advances in the formulation and development of photocatalytic disinfection, design of efficient photocatalysts, choice of photocatalytic reactor, removal and/or disinfection mechanisms, and the role of reactive ion species. Data from recent studies are analyzed to accurately assess the efficacy of such disinfection approaches. This review also highlights the application of innovative materials in individual and combined abatement systems against airborne bacterial, viral, and fungal pathogens. We discuss the efficiency and benefits presented by such systems, address the challenges, and provide a perspective for future research.
Collapse
Affiliation(s)
- Younes Ahmadi
- Department of Analytical Chemistry, Kabul University, Kabul 1001, Afghanistan
| | - Neha Bhardwaj
- Department of Biotechnology, University Institute of Engineering Technology (UIET), Panjab University, Chandigarh, India
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Republic of Korea.
| | - Sandeep Kumar
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar, Haryana 125001, India.
| |
Collapse
|
48
|
Mei Y, Yang TR, Ou W, Zheng ZM, Long H, Ying LY, Zhang BP. Low-threshold wavelength-tunable ultraviolet vertical-cavity surface-emitting lasers from 376 to 409 nm. FUNDAMENTAL RESEARCH 2021. [DOI: 10.1016/j.fmre.2021.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
49
|
Sueker M, Stromsodt K, Gorji HT, Vasefi F, Khan N, Schmit T, Varma R, Mackinnon N, Sokolov S, Akhbardeh A, Liang B, Qin J, Chan DE, Baek I, Kim MS, Tavakolian K. Handheld Multispectral Fluorescence Imaging System to Detect and Disinfect Surface Contamination. SENSORS 2021; 21:s21217222. [PMID: 34770529 PMCID: PMC8588002 DOI: 10.3390/s21217222] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 10/25/2021] [Accepted: 10/27/2021] [Indexed: 12/14/2022]
Abstract
Contamination inspection is an ongoing concern for food distributors, restaurant owners, caterers, and others who handle food. Food contamination must be prevented, and zero tolerance legal requirements and damage to the reputation of institutions or restaurants can be very costly. This paper introduces a new handheld fluorescence-based imaging system that can rapidly detect, disinfect, and document invisible organic residues and biofilms which may host pathogens. The contamination, sanitization inspection, and disinfection (CSI-D) system uses light at two fluorescence excitation wavelengths, ultraviolet C (UVC) at 275 nm and violet at 405 nm, for the detection of organic residues, including saliva and respiratory droplets. The 275 nm light is also utilized to disinfect pathogens commonly found within the contaminated residues. Efficacy testing of the neutralizing effects of the ultraviolet light was conducted for Aspergillus fumigatus, Streptococcus pneumoniae, and the influenza A virus (a fungus, a bacterium, and a virus, respectively, each commonly found in saliva and respiratory droplets). After the exposure to UVC light from the CSI-D, all three pathogens experienced deactivation (> 99.99%) in under ten seconds. Up to five-log reductions have also been shown within 10 s of UVC irradiation from the CSI-D system.
Collapse
Affiliation(s)
- Mitchell Sueker
- Biomedical Engineering Program, University of North Dakota, Grand Forks, ND 58202, USA; (M.S.); (K.S.); (H.T.G.); (B.L.)
| | - Kristen Stromsodt
- Biomedical Engineering Program, University of North Dakota, Grand Forks, ND 58202, USA; (M.S.); (K.S.); (H.T.G.); (B.L.)
| | - Hamed Taheri Gorji
- Biomedical Engineering Program, University of North Dakota, Grand Forks, ND 58202, USA; (M.S.); (K.S.); (H.T.G.); (B.L.)
| | - Fartash Vasefi
- SafetySpect Inc., 4200 James Ray Dr., Grand Forks, ND 58202, USA; (F.V.); (N.M.); (S.S.); (A.A.)
| | - Nadeem Khan
- School of Medicine and Health Sciences, University of North Dakota, Grand Forks, ND 58202, USA; (N.K.); (T.S.); (R.V.)
| | - Taylor Schmit
- School of Medicine and Health Sciences, University of North Dakota, Grand Forks, ND 58202, USA; (N.K.); (T.S.); (R.V.)
| | - Rangati Varma
- School of Medicine and Health Sciences, University of North Dakota, Grand Forks, ND 58202, USA; (N.K.); (T.S.); (R.V.)
| | - Nicholas Mackinnon
- SafetySpect Inc., 4200 James Ray Dr., Grand Forks, ND 58202, USA; (F.V.); (N.M.); (S.S.); (A.A.)
| | - Stanislav Sokolov
- SafetySpect Inc., 4200 James Ray Dr., Grand Forks, ND 58202, USA; (F.V.); (N.M.); (S.S.); (A.A.)
| | - Alireza Akhbardeh
- SafetySpect Inc., 4200 James Ray Dr., Grand Forks, ND 58202, USA; (F.V.); (N.M.); (S.S.); (A.A.)
| | - Bo Liang
- Biomedical Engineering Program, University of North Dakota, Grand Forks, ND 58202, USA; (M.S.); (K.S.); (H.T.G.); (B.L.)
| | - Jianwei Qin
- USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, Beltsville, MD 20705, USA; (J.Q.); (D.E.C.); (I.B.); (M.S.K.)
| | - Diane E. Chan
- USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, Beltsville, MD 20705, USA; (J.Q.); (D.E.C.); (I.B.); (M.S.K.)
| | - Insuck Baek
- USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, Beltsville, MD 20705, USA; (J.Q.); (D.E.C.); (I.B.); (M.S.K.)
| | - Moon S. Kim
- USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, Beltsville, MD 20705, USA; (J.Q.); (D.E.C.); (I.B.); (M.S.K.)
| | - Kouhyar Tavakolian
- Biomedical Engineering Program, University of North Dakota, Grand Forks, ND 58202, USA; (M.S.); (K.S.); (H.T.G.); (B.L.)
- Correspondence:
| |
Collapse
|
50
|
Bhardwaj SK, Singh H, Deep A, Khatri M, Bhaumik J, Kim KH, Bhardwaj N. UVC-based photoinactivation as an efficient tool to control the transmission of coronaviruses. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 792:148548. [PMID: 34465056 PMCID: PMC8238411 DOI: 10.1016/j.scitotenv.2021.148548] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/28/2021] [Accepted: 06/15/2021] [Indexed: 05/04/2023]
Abstract
The ongoing COVID-19 pandemic made us re-realize the importance of environmental disinfection and sanitation in indoor areas, hospitals, and clinical rooms. UVC irradiation of high energy and short wavelengths, especially in the 200-290-nm range possesses the great potential for germicidal disinfection. These properties of UVC allow to damage or destruct the nucleic acids (DNA/RNA) in diverse microbes (e.g., bacteria, fungi, and viruses). UVC light can hence be used as a promising tool for prevention and control of their infection or transmission. The present review offers insights into the historical perspective, mode of action, and recent advancements in the application of UVC-based antiviral therapy against coronaviruses (including SARS CoV-2). Moreover, the application of UVC lights in the sanitization of healthcare units, public places, medical instruments, respirators, and personal protective equipment (PPE) is also discussed. This article, therefore, is expected to deliver a new path for the developments of UVC-based viricidal approach.
Collapse
Affiliation(s)
- Sanjeev K Bhardwaj
- Department of Nanomaterials and Application Technology, Center of Innovative and Applied Bioprocessing, Sector 81 (Knowledge City), S.A.S. Nagar 140306, Punjab, India
| | - Harpreet Singh
- Department of Biotechnology, University Institute of Engineering Technology (UIET), Panjab University, Chandigarh, India
| | - Akash Deep
- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh 160030, India
| | - Madhu Khatri
- Department of Biotechnology, University Institute of Engineering Technology (UIET), Panjab University, Chandigarh, India
| | - Jayeeta Bhaumik
- Department of Nanomaterials and Application Technology, Center of Innovative and Applied Bioprocessing, Sector 81 (Knowledge City), S.A.S. Nagar 140306, Punjab, India
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Republic of Korea.
| | - Neha Bhardwaj
- Department of Biotechnology, University Institute of Engineering Technology (UIET), Panjab University, Chandigarh, India.
| |
Collapse
|