1
|
Does Size Matter? Comparison of Extraction Yields for Different-Sized DNA Fragments by Seven Different Routine and Four New Circulating Cell-Free Extraction Methods. J Clin Microbiol 2018; 56:JCM.01061-18. [PMID: 30282788 DOI: 10.1128/jcm.01061-18] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 09/26/2018] [Indexed: 12/13/2022] Open
Abstract
An element essential for PCR detection of microbial agents in many sample types is the extraction step, designed to purify nucleic acids. Despite the importance of this step, yields have not been extensively compared across methods to determine whether the method used contributes to quantitative differences and the lack of commutability seen with existing clinical methods. This may in part explain why plasma and blood viral load assays have proven difficult to standardize. Also, studies have identified small DNA fragments of <200 bp in plasma (cell-free DNA [cfDNA]), which may include significant quantities of viral DNA. Our study evaluated extraction yields for 11 commercially available extraction methods, including 4 new methods designed to isolate cfDNA. Solutions of DNA fragments with sizes ranging from 50 to 1,500 bp were extracted, and then the eluates were tested by droplet digital PCR to determine the DNA fragment yield for each method. The results demonstrated a wide range of extraction yields across the variety of methods/instruments used, with the 50- and 100-bp fragment sizes showing especially inconsistent quantitative results and poor yields of less than 20%. Slightly higher, more consistent yields were seen with 2 of the 4 circulating cell-free extraction kits. These results demonstrate a significant need for further evaluation of nucleic acid yields across the variety of extraction platforms and highlight the poor extraction yields of small DNA fragments by existing methods. Further work is necessary to determine the impact of this inconsistency across instruments and the relevance of the low yields for smaller DNA fragments in clinical virology testing.
Collapse
|
2
|
Abstract
Nucleic acid extraction is the first step of any amplification experiment no matter what kind of amplification is used to detect a specific pathogen. Efficient nucleic acid extraction is essential to obtain good results using any molecular test. The optimal extraction method should fulfill the following conditions: speed, short working time, cost-effectiveness, high sensitivity and specificity, good reproducibility, and safety. The methods can be divided into solution or column based according to differences of their principles. The automated extraction instruments have many advantages, and these have proven to be very useful. Moreover, in recent years, fully automated instruments combining NA extraction and amplification have been commercially available. However, the method itself does not provide assurance, and the DNA recovery can be different among various kits or instruments that use the similar principles. Therefore, it is important to carefully evaluate the performance of any extraction method used in the clinical microbiology laboratory even though manufacturers may have reported good validation results with specific organisms.
Collapse
Affiliation(s)
- Yi-Wei Tang
- Departments of Laboratory Medicine and Internal Medicine, Memorial Sloan Kettering Cancer Center, New York, NY USA
| | - Charles W. Stratton
- Department of Pathology, Microbiology and Immunology and Medicine, Vanderbilt University Medical Center, Nashville, TN USA
| |
Collapse
|
3
|
Rashid H, Shafi S, Booy R, Bashir HE, Ali K, Zambon MC, Memish ZA, Ellis J, Coen PG, Haworth E. Influenza and respiratory syncytial virus infections in British Hajj pilgrims. EMERGING HEALTH THREATS JOURNAL 2017. [DOI: 10.3402/ehtj.v1i0.7072] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- H Rashid
- Academic Unit of Child Health, Queen Mary University of London, London, UK
| | - S Shafi
- HPA Collaborating Laboratory, Department of Microbiology, Northwick Park Hospital, Middlesex, UK
| | - R Booy
- Academic Unit of Child Health, Queen Mary University of London, London, UK
- National Centre for Immunisation Research and Surveillance of Vaccine Preventable Disease, The Children’s Hospital at Westmead, The University of Sydney, Sydney, New South Wales, Australia
| | - H El Bashir
- Academic Unit of Child Health, Queen Mary University of London, London, UK
| | - K Ali
- Academic Unit of Child Health, Queen Mary University of London, London, UK
| | - MC Zambon
- Respiratory Virus Unit, Centre for Infections, Health Protection Agency, London, UK
| | - ZA Memish
- Department of Medicine, King Abdulaziz Medical City, National Guard Health Affairs, Riyadh, Saudi Arabia
- Department of Infection Prevention and Control, King Abdulaziz Medical City, National Guard Health Affairs, Riyadh; Saudi Arabia
| | - J Ellis
- Respiratory Virus Unit, Centre for Infections, Health Protection Agency, London, UK
| | - PG Coen
- Infection Control Office, Windeyer Institute of Medical Sciences, University College. London Hospitals NHS Trust, London, UK; and
| | - E Haworth
- Thames Valley Health Protection Unit, Health Protection Agency South East, Oxford, UK
| |
Collapse
|
4
|
Bailey AM, Pajak L, Fruchey IR, Cowan CA, Emanuel PA. Robotic Nucleic Acid Isolation Using a Magnetic Bead Resin and an Automated Liquid Handler for Biological Agent Simulants. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/s1535-5535(03)00016-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The events that occurred following the mailing of Bacillus anthracis-laced envelopes through the postal system has highlighted the need to perform biological screening on large numbers of environmental samples. High-throughput screening that relies on integrated robotic systems to speed analysis has been undertaken to handle the surge in samples requiring testing in events involving weapons of mass destruction. These automated screening systems require DNA extraction methods capable of handling environmental samples that contain inhibitors and have target organisms at low concentrations. This study describes the development of a method for the detection of the biological warfare agent simulants Erwinia herbicola and Bacillus subtilis var. niger spores using paramagnetic bead-based resin with an automated liquid handler and environmental samples.
Collapse
Affiliation(s)
| | | | | | | | - Peter A. Emanuel
- U.S. Army Edgewood Chemical Biological Center, Aberdeen Proving Ground, MD
| |
Collapse
|
5
|
Granato PA, DeGilio MA, Wilson EM. The unexpected detection of varicella-zoster virus in genital specimens using the Lyra™ Direct HSV 1+2/VZV Assay. J Clin Virol 2016; 84:87-89. [PMID: 27756008 DOI: 10.1016/j.jcv.2016.10.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 10/04/2016] [Accepted: 10/07/2016] [Indexed: 11/15/2022]
Abstract
BACKGROUND The Lyra™ Direct HSV 1+2/VZV Assay is a moderately complex, multiplex PCR assay that qualitatively detects the presence of HSV 1, HSV 2, and VZV DNA in cutaneous and mucocutaneous specimens with a time-to-result of less than 60min. OBJECTIVES To report a one-year laboratory experience using Lyra assay for testing cutaneous and mucocutaneous specimens for HSV and VZV that resulted in the unexpected detection of VZV in 14 male and female genital specimens. STUDY DESIGN Over a one-year period, 2113 cutaneous and mucocutaneous specimens from male and female patients were submitted for testing using the Lyra assay. An unexpected 14 genital specimens were positive for the presence VZV DNA. Eleven of the 14 specimens were available for confirmatory testing using two alternative molecular methods and Sanger sequencing. RESULTS Fourteen male and female genital specimens were positive for the presence of VZV DNA. All of the 11 specimens (9 female and 2 male) that were available for confirmatory testing by the alternative molecular method and Sanger sequencing were confirmed as containing VZV DNA. CONCLUSIONS Using of the Lyra assay over a one-year time period, VZV DNA was detected in 126 specimens of which 14 (11.1%) were from male and female genital sites. This rare and unexpected finding suggests that the appearance of zoster lesions in the genital area may not be as uncommon as previously thought and that this finding would have considerable impact on patient counseling and public health considerations.
Collapse
MESH Headings
- Adult
- Aged
- Aged, 80 and over
- DNA, Viral/analysis
- Female
- Genitalia, Female/virology
- Genitalia, Male/virology
- Herpes Simplex/diagnosis
- Herpes Simplex/virology
- Herpes Zoster/diagnosis
- Herpes Zoster/virology
- Herpesvirus 1, Human/genetics
- Herpesvirus 1, Human/isolation & purification
- Herpesvirus 2, Human/genetics
- Herpesvirus 2, Human/isolation & purification
- Herpesvirus 3, Human/genetics
- Herpesvirus 3, Human/isolation & purification
- Humans
- Male
- Middle Aged
- Multiplex Polymerase Chain Reaction
- Reagent Kits, Diagnostic
- Skin/virology
- Specimen Handling
- Time Factors
- Young Adult
Collapse
Affiliation(s)
- Paul A Granato
- Laboratory Alliance of Central New York, United States; SUNY Upstate Medical University, Syracuse, NY, United States.
| | | | | |
Collapse
|
6
|
Rapid and direct detection of herpes simplex virus in cerebrospinal fluid by use of a commercial real-time PCR assay. J Clin Microbiol 2014; 52:4361-2. [PMID: 25274992 DOI: 10.1128/jcm.02623-14] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Central nervous system infection due to herpes simplex virus (HSV) is a medical emergency and requires rapid diagnosis and initiation of therapy. In this study, we compared a routine real-time PCR assay for HSV types 1 (HSV-1) and 2 (HSV-2) to a recently FDA-approved direct PCR assay (Simplexa HSV-1/2 Direct; Focus Diagnostics, Cypress, CA) using cerebrospinal fluid samples (n = 100). The Simplexa HSV-1/2 assays demonstrated a combined sensitivity and specificity of 96.2% (50/52) and 97.9% (47/48), respectively. In addition, the Simplexa assay does not require nucleic acid extraction, and the results are available in 60 min.
Collapse
|
7
|
Inhibition controls for qualitative real-time PCR assays: are they necessary for all specimen matrices? J Clin Microbiol 2014; 52:2139-43. [PMID: 24740078 DOI: 10.1128/jcm.03389-13] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
A retrospective analysis of 386,706 specimens representing a variety of matrix types used in qualitative real-time PCR assays determined the overall inhibition rate to be 0.87% when the inhibition control was added preextraction to 5,613 specimens and 0.01% when the inhibition control was added postextraction but preamplification in 381,093 specimens. Inhibition rates of ≤ 1% were found for all specimen matrix types except urine and formalin-fixed, paraffin-embedded tissue.
Collapse
|
8
|
Ince J, McNally A. Development of rapid, automated diagnostics for infectious disease: advances and challenges. Expert Rev Med Devices 2014; 6:641-51. [DOI: 10.1586/erd.09.46] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
9
|
Abstract
Since thermostable Taq DNA polymerase was discovered in 1987, nucleic acid amplification techniques have made great strides and contributed greatly to progress in the life sciences. These techniques were introduced into the clinical laboratory and have produced great changes in diagnostic tools and tests. In particular, there have been many innovative molecular testing developments in the field of diagnostic microbiology.
Collapse
|
10
|
Abstract
Herpes simplex virus (HSV) is one of the most common, yet frequently overlooked, sexually transmitted infections. Since the type of HSV infection affects prognosis and subsequent counseling, type-specific testing to distinguish HSV-1 from HSV-2 is recommended. Although PCR has been the diagnostic standard for HSV infections of the central nervous system, until now viral culture has been the test of choice for HSV genital infection. However, HSV PCR, with its consistently and substantially higher rate of HSV detection, will likely replace viral culture as the gold standard for the diagnosis of genital herpes in people with active mucocutaneous lesions, regardless of anatomic location or viral type. Alternatively, type-specific serologic tests based on glycoprotein G should be the test of choice to establish the diagnosis of HSV infection when no active lesion is present. Given the difficulty in making the clinical diagnosis of HSV, the growing worldwide prevalence of genital herpes and the availability of effective antiviral therapy, there is an increased demand for rapid, accurate laboratory diagnosis of patients with HSV.
Collapse
|
11
|
Update on the Detection and Characterization of Bacterial Pathogens by Nucleic Acid Amplification. Mol Microbiol 2011. [DOI: 10.1128/9781555816834.ch23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
12
|
Geertsen R, Friderich P, Dobec M, Emler S. Evaluation of an automated extraction method for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Cobas Amplicor PCR from different sample materials. ACTA ACUST UNITED AC 2009; 39:405-8. [PMID: 17464862 DOI: 10.1080/00365540601087582] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
A commercially available automated device (MagNA Pure LC) was adapted for nucleic acid extraction of urogenital specimen for subsequent PCR detection of Chlamydia trachomatis and Neisseria gonorrhoeae in a clinical laboratory. Results were compared to the standard manual extraction procedure and showed excellent correlation, with even slightly increased sensitivity.
Collapse
Affiliation(s)
- Ralf Geertsen
- Institute Virion Ltd., Molecular Biology, Rueschlikon, Switzerland.
| | | | | | | |
Collapse
|
13
|
Alp A, Hascelik G. Comparison of 3 nucleic acid isolation methods for the quantification of HIV-1 RNA by Cobas Taqman real-time polymerase chain reaction system. Diagn Microbiol Infect Dis 2009; 63:365-71. [DOI: 10.1016/j.diagmicrobio.2008.12.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2008] [Revised: 11/24/2008] [Accepted: 12/15/2008] [Indexed: 11/15/2022]
|
14
|
Kasai M, Harrington SM, Francesconi A, Petraitis V, Petraitiene R, Beveridge MG, Knudsen T, Milanovich J, Cotton MP, Hughes J, Schaufele RL, Sein T, Bacher J, Murray PR, Kontoyiannis DP, Walsh TJ. Detection of a molecular biomarker for zygomycetes by quantitative PCR assays of plasma, bronchoalveolar lavage, and lung tissue in a rabbit model of experimental pulmonary zygomycosis. J Clin Microbiol 2008; 46:3690-702. [PMID: 18845827 PMCID: PMC2576616 DOI: 10.1128/jcm.00917-08] [Citation(s) in RCA: 98] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2008] [Revised: 06/29/2008] [Accepted: 09/02/2008] [Indexed: 01/01/2023] Open
Abstract
We developed two real-time quantitative PCR (qPCR) assays, targeting the 28S rRNA gene, for the diagnosis of zygomycosis caused by the most common, clinically significant Zygomycetes. The amplicons of the first qPCR assay (qPCR-1) from Rhizopus, Mucor, and Rhizomucor species were distinguished through melt curve analysis. The second qPCR assay (qPCR-2) detected Cunninghamella species using a different primer/probe set. For both assays, the analytic sensitivity for the detection of hyphal elements from germinating sporangiospores in bronchoalveolar lavage (BAL) fluid and lung tissue homogenates from rabbits was 1 to 10 sporangiospores/ml. Four unique and clinically applicable models of invasive pulmonary zygomycosis served as surrogates of human infections, facilitating the validation of these assays for potential diagnostic utility. For qPCR-1, 5 of 98 infarcted lung specimens were positive by qPCR and negative by quantitative culture (qCx). None were qCx positive only. Among 23 BAL fluid samples, all were positive by qPCR, while 22 were positive by qCx. qPCR-1 detected Rhizopus and Mucor DNA in 20 (39%) of 51 serial plasma samples as early as day 1 postinoculation. Similar properties were observed for qPCR-2, which showed greater sensitivity than qCx for BAL fluid (100% versus 67%; P = 0.04; n = 15). The assay detected Cunninghamella DNA in 18 (58%) of 31 serial plasma samples as early as day 1 postinoculation. These qPCR assays are sensitive and specific for the detection of Rhizopus, Mucor, Rhizomucor, and Cunninghamella species and can be used for the study and detection of infections caused by these life-threatening pathogens.
Collapse
Affiliation(s)
- Miki Kasai
- Immunocompromised Host Section, Pediatric Oncology Branch, National Cancer Institute, Building 10-CRC, Room 1-5740, Bethesda, MD 20892, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Rashid H, Shafi S, Booy R, El Bashir H, Ali K, Zambon M, Memish Z, Ellis J, Coen P, Haworth E. Influenza and respiratory syncytial virus infections in British Hajj pilgrims. EMERGING HEALTH THREATS JOURNAL 2008; 1:e2. [PMID: 22460211 PMCID: PMC3167590 DOI: 10.3134/ehtj.08.002] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2006] [Revised: 09/03/2007] [Accepted: 09/27/2007] [Indexed: 11/18/2022]
Abstract
Viral respiratory infections including influenza and respiratory syncytial virus (RSV) have been reported during the Hajj among international pilgrims. To help establish the burden of these infections at the Hajj, we set up a study to confirm these diagnoses in symptomatic British pilgrims who attended the 2005 Hajj. UK pilgrims with symptoms of upper respiratory tract infection (URTI) were invited to participate; after taking medical history, nasal swabs were collected for point-of-care testing (PoCT) of influenza and for subsequent PCR analysis for influenza and RSV. Of the 205 patients recruited, 37 (18%) were positive for either influenza or RSV. Influenza A (H3) accounted for 54% (20/37) of the virus-positive samples, followed by RSV 24% (9/37), influenza B 19% (7/37), and influenza A (H1) 3% (1/37). Of the influenza-positive cases, 29% (8/28) had recently had a flu immunisation. Influenza was more common in those who gave a history of contact with a pilgrim with a respiratory illness than those who did not (17 versus 9%). The overall rate of RSV was 4% (9/202). This study confirms that influenza and RSV cause acute respiratory infections in British Hajj pilgrims. Continuing surveillance and a programme of interventions to contain the spread of infection are needed at the Hajj, particularly when the world is preparing for an influenza pandemic.
Collapse
Affiliation(s)
- H Rashid
- Academic Unit of Child Health, Queen Mary University of London, London, UK
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Rekhviashvili N, Stevens W, Marinda E, Gonin R, Stevens G, McIntyre J, Wood R. Clinical performance of an in-house real-time RT-PCR assay using a fluorogenic LUX™ primer for quantitation of human immunodeficiency virus type-1 (HIV-1). J Virol Methods 2007; 146:14-21. [PMID: 17628709 DOI: 10.1016/j.jviromet.2007.05.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2006] [Revised: 05/16/2007] [Accepted: 05/21/2007] [Indexed: 10/23/2022]
Abstract
The South African National Antiretroviral Treatment Guideline recommends the use of HIV viral load assays for routine monitoring of HIV-1 positive patients on Highly Active Antiretroviral Therapy (HAART). Approved commercial HIV-1 viral load assays are expensive for developing countries where a large number of patients are treated in the public sector. The evaluation of an in-house HIV-1 viral load assay (LUX assay) is described using 458 plasma specimens. Good specificity of the LUX assay was demonstrated using 50 seronegative plasma specimens. A group of 142 HIV-1 positive patients was used to assess the agreement between the LUX assay and the COBAS Amplicor assay. An intra class correlation (ICC) coefficient of 0.85 (CI 95%) indicated good agreement between the assays. The Bland-Altman model showed good agreement between the assays for approximately 87% of the results (mean 0.03 [-1.26; 1.32], CI 95%). In a cohort of 55 patients followed-up longitudinally the LUX assay showed similar declines in viral load to the COBAS Amplicor assay in response to therapy. Viral rebound was detected in 5 patients out of 55 by both assays. Thus, the LUX assay compares well to the gold standard and represents an affordable alternative for high volume testing in resource limited settings.
Collapse
Affiliation(s)
- Natela Rekhviashvili
- Department of Molecular Medicine and Hematology, National Health Laboratory Service (NHLS), University of the Witwatersrand (WITS), Faculty of Health Science, Medical School, 7 York Road, Parktown, Johannesburg 2193, South Africa.
| | | | | | | | | | | | | |
Collapse
|
17
|
Tewari D, Zellers C, Acland H, Pedersen JC. Automated extraction of avian influenza virus for rapid detection using real-time RT-PCR. J Clin Virol 2007; 40:142-5. [PMID: 17875401 DOI: 10.1016/j.jcv.2007.07.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2007] [Revised: 07/16/2007] [Accepted: 07/19/2007] [Indexed: 11/15/2022]
Abstract
BACKGROUND Highly pathogenic H5N1 avian influenza (AI) poses a grave risk to human health. An important aspect of influenza control is rapid diagnosis. OBJECTIVES This study describes the efficiency of AI-RNA extraction utilizing silica-based magnetic beads with robotics and its detection with an influenza A matrix gene real-time RT-PCR from tracheal swabs, and compares it to virus isolation and manual spin column extractions. STUDY DESIGN Analytical sensitivity was assessed by performing dilution analysis and detection of H2N2 AI viral RNA. Diagnostic sensitivity and specificity was assessed by analyzing tracheal swabs collected from H7N2 infected and uninfected chickens. RESULTS Both manual and robotic extractions detected AI virus at 1log(10)EID(50)/ml. Diagnostic sensitivity and specificity of matrix gene detection with the automated extraction method for chicken tracheal swab specimens was similar to that of virus isolation and the manual extraction method. There were only three discordant results among 212 tested specimens. CONCLUSION The main advantages of automated robotic viral nucleic acid extraction are high throughput processing; hands-free operation; and reduction in human and technical error. This study demonstrates successful detection of influenza A virus with magnetic beads utilizing the Qiagen MagAttract cell kit on a BioRobot M48 platform.
Collapse
Affiliation(s)
- Deepanker Tewari
- Microbiology Services, Pennsylvania Veterinary Laboratory, Harrisburg, PA 17110, USA.
| | | | | | | |
Collapse
|
18
|
Comparative evaluation of in-house manual, and commercial semi-automated and automated DNA extraction platforms in the sample preparation of human stool specimens for a Salmonella enterica 5'-nuclease assay. J Microbiol Methods 2007; 71:238-45. [PMID: 17942177 DOI: 10.1016/j.mimet.2007.09.003] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2007] [Revised: 08/27/2007] [Accepted: 09/11/2007] [Indexed: 11/22/2022]
Abstract
In the present study, three methods (NucliSens miniMAG [bioMérieux], MagNA Pure DNA Isolation Kit III Bacteria/Fungi [Roche], and a silica-guanidiniumthiocyanate {Si-GuSCN-F} procedure for extracting DNA from stool specimens were compared with regard to analytical performance (relative DNA recovery and down stream real-time PCR amplification of Salmonella enterica DNA), stability of the extracted DNA, hands-on time (HOT), total processing time (TPT), and costs. The Si-GuSCN-F procedure showed the highest analytical performance (relative recovery of 99%, S. enterica real-time PCR sensitivity of 91%) at the lowest associated costs per extraction (euro 4.28). However, this method did required the longest HOT (144 min) and subsequent TPT (176 min) when processing 24 extractions. Both miniMAG and MagNA Pure extraction showed similar performances at first (relative recoveries of 57% and 52%, S. enterica real-time PCR sensitivity of 85%). However, when difference in the observed Ct values after real-time PCR were taken into account, MagNA Pure resulted in a significant increase in Ct value compared to both miniMAG and Si-GuSCN-F (with on average +1.26 and +1.43 cycles). With regard to inhibition all methods showed relatively low inhibition rates (< 4%), with miniMAG providing the lowest rate (0.7%). Extracted DNA was stable for at least 1 year for all methods. HOT was lowest for MagNA Pure (60 min) and TPT was shortest for miniMAG (121 min). Costs, finally, were euro 4.28 for Si-GuSCN, euro 6.69 for MagNA Pure and euro 9.57 for miniMAG.
Collapse
|
19
|
Smith TF, Espy MJ, Mandrekar J, Jones MF, Cockerill FR, Patel R. Quantitative real-time polymerase chain reaction for evaluating DNAemia due to cytomegalovirus, Epstein-Barr virus, and BK virus in solid-organ transplant recipients. Clin Infect Dis 2007; 45:1056-61. [PMID: 17879925 DOI: 10.1086/521909] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2007] [Accepted: 05/29/2007] [Indexed: 12/30/2022] Open
Abstract
Testing for cytomegalovirus-, Epstein-Barr virus-, and BK virus-specific gene targets in specimens from solid-organ transplant recipients for DNA by quantitative real-time polymerase chain reaction has been implemented in many diagnostic facilities. This technology provides rapid, accurate, and reproducible results for early detection, monitoring, and medical management of patients with these infections. Because these assays are becoming commonly used in clinical practice, the technical variables associated with specimen processing (e.g., nucleic acid extraction, gene target, and result reporting), amplification, and unique patient characteristics (e.g., age, sex, underlying diseases, immune status, and immunosuppressive regimens received) are factors that may influence the understanding and interpretation of test results. We emphasize the need for standardization of existing variables through parallel comparative and proficiency testing, uniform units for expressing results, to provide for clinical correlation with the results of these molecular assays.
Collapse
Affiliation(s)
- Thomas F Smith
- Division of Clinical Microbiology, Mayo Clinic and Foundation, Rochester, MN 55905, USA.
| | | | | | | | | | | |
Collapse
|
20
|
Rashid H, Shafi S, Haworth E, El Bashir H, Ali KA, Memish ZA, Booy R. Value of rapid testing for influenza among Hajj pilgrims. Travel Med Infect Dis 2007; 5:310-3. [PMID: 17870637 DOI: 10.1016/j.tmaid.2007.07.006] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2007] [Revised: 07/18/2007] [Accepted: 07/24/2007] [Indexed: 10/22/2022]
Abstract
BACKGROUND Muslim pilgrims going on the Hajj are at risk of influenza. The treatment and prevention of influenza with antiviral drugs depends on rapid diagnosis using a near-patient test such as the QuickVue influenza test. The suitability of this test among pilgrims has not been studied in the past and this study assesses the usefulness of the test for diagnosing influenza among those attending the Hajj. METHODS The sensitivity and specificity of the QuickVue test were measured against reverse transcriptase polymerase chain reaction by undertaking the tests on nasal swab samples from pilgrims. RESULTS The sensitivity and specificity of the QuickVue test were 22% and 99%, respectively, and its likelihood ratio for a positive and a negative test were 22 and 0.79 in that order. CONCLUSION The QuickVue influenza test using nasal swabs is poorly sensitive for diagnosing influenza among Hajj pilgrims. Given its high specificity and an even higher likelihood ratio for a positive test it may still be a very useful tool for influenza surveillance at the Hajj.
Collapse
Affiliation(s)
- Harunor Rashid
- Academic Unit of Child Health, Queen Mary University of London, UK.
| | | | | | | | | | | | | |
Collapse
|
21
|
Garcia-Effron G, Gamarra S, Crooke A, Martínez-Sánchez P, Lahuerta J, Martínez-López J. Comparison of the MagNA pure LC automated system and the RiboPure-Blood RNA manual method for RNA extraction from multiple myeloma bone marrow samples conserved in an RNA stabilizer. Int J Lab Hematol 2007; 29:139-44. [PMID: 17474887 DOI: 10.1111/j.1751-553x.2006.00830.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A total of 62 frozen bone marrow specimens conserved in RNA later (Ambion) were processed using two different extraction methods, the MagNA Pure LC system (MAG; Roche) and the manual RiboPure-Blood RNA method (RIBO; Ambion); Beta glucoronidase RNA (GUS) was amplified by LightCycler PCR to evaluate the quality of both extraction procedures. Less than 1000 GUS copies/ml was detected in 26 of 62 specimens (41.94%) processed by MAG and in five of 62 specimens (8.06%) processed by RIBO. Moreover, RNA recovery from the 62 specimens by MAG is, on average, 2.91 cycle threshold-fold higher than RIBO (P = 0.0008). Furthermore, we compared the extraction times and reagent costs of both methods. In conclusion, RNA extraction using MAG is faster to process 32 samples and less expensive than RIBO but it is not sensitive enough to be employed for research purpose in our laboratory.
Collapse
Affiliation(s)
- G Garcia-Effron
- Laboratorio de Biología Molecular, Servicio de Hematología, Hospital Universitario, Madrid, Spain.
| | | | | | | | | | | |
Collapse
|
22
|
GARCIA-EFFRON G, GAMARRA S, CROOKE A, MARTÍNEZ-SÁNCHEZ P, LAHUERTA J, MARTÍNEZ-LÓPEZ J. Comparison of the MagNA pure LC automated system and the RiboPure-Blood RNA manual method for RNA extraction from multiple myeloma bone marrow samples conserved in an RNA stabilizer. Int J Lab Hematol 2006. [DOI: 10.1111/j.1365-2257.2006.00830.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
23
|
Allawi HT, Li H, Sander T, Aslanukov A, Lyamichev VI, Blackman A, Elagin S, Tang YW. Invader plus method detects herpes simplex virus in cerebrospinal fluid and simultaneously differentiates types 1 and 2. J Clin Microbiol 2006; 44:3443-7. [PMID: 16954297 PMCID: PMC1594729 DOI: 10.1128/jcm.01175-06] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We report here on the development and validation of a prototype Invader Plus method for the qualitative detection of herpes simplex virus types 1 and 2 in cerebrospinal fluid (CSF). The method combines PCR and Invader techniques in a single, closed-tube, continuous-reaction format that gives an analytical sensitivity of approximately 10 copies per reaction. The clinical sensitivity and specificity were 100.0% and 98.6%, respectively, when the results of the method were validated against the results obtained with a PCR colorimetric microtiter plate system by use of clinical CSF specimens.
Collapse
Affiliation(s)
- Hatim T Allawi
- Third Wave Technologies, Inc., 502 South Rosa Rd., Madison, WI 53719, USA.
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Espy MJ, Uhl JR, Sloan LM, Buckwalter SP, Jones MF, Vetter EA, Yao JDC, Wengenack NL, Rosenblatt JE, Cockerill FR, Smith TF. Real-time PCR in clinical microbiology: applications for routine laboratory testing. Clin Microbiol Rev 2006; 19:165-256. [PMID: 16418529 PMCID: PMC1360278 DOI: 10.1128/cmr.19.1.165-256.2006] [Citation(s) in RCA: 800] [Impact Index Per Article: 44.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Collapse
Affiliation(s)
- M J Espy
- Mayo Clinic, 200 First St. SW, Hilton 470, Rochester, MN 55905, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Abstract
In the 21st century, one of the greatest challenges to public health and clinical microbiologists is the rapid detection and identification of emerging and reemerging pathogens. Complex factors such as genetic variation in the host and pathogen, environmental changes, population pressures, and global travel can all influence the emergence of infectious diseases. The SARS epidemic of 2003 highlighted the potential of an emerging pathogen to spread globally in a very short time frame (Peruski and Peruski, 2003). The diagnostics of such infectious diseases has been greatly affected in the past 20 years. No longer is cultivation and microscopy the only means of detecting infectious agents. With the introduction of molecular diagnostics, the ability to detect minute amounts of microbial nucleic acids in clinical specimens has revolutionized clinical microbiology. In particular, the utility of PCR allows the detection and quantitation of specific agents in a matter of hours. PCR sequencing of specific segments of nucleic acid allows for the determination of specific drug resistance that now aids in guiding viral therapies.
Collapse
|
26
|
Tang YW, Sefers SE, Li H, Kohn DJ, Procop GW. Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens. J Clin Microbiol 2005; 43:4830-3. [PMID: 16145151 PMCID: PMC1234094 DOI: 10.1128/jcm.43.9.4830-4833.2005] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.
Collapse
Affiliation(s)
- Yi-Wei Tang
- Department of Medicine, Vanderbilt University School of Medicine, Nashville, Tennessee 37232-5310, USA.
| | | | | | | | | |
Collapse
|
27
|
Oliveira TCRM, Barbut S, Griffiths MW. A robotic DNA purification protocol and real-time PCR for the detection of Campylobacter jejuni in foods. J Food Prot 2005; 68:2131-5. [PMID: 16245718 DOI: 10.4315/0362-028x-68.10.2131] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Primers designed to amplify a Campylobacter jejuni cadF gene sequence were used in an SYBR Green I real-time PCR assay as an alternative to conventional bacteriological methods for the rapid detection of C. jejuni in foods. Twenty-five grams of chicken skin (breast and thigh) was contaminated by adding approximately 1, 10, or 50 CFU of C. jejuni ATCC 35560. Twenty-five grams of pork and 25-ml aliquots of milk were also inoculated with 1 and 10 CFU of the pathogen. The samples were incubated in Bolton broth for different periods at 37 and 42 degrees C under microaerophilic conditions. Using a commercial robotic DNA purification system, DNA was extracted and purified from 1-ml aliquots of the enrichment cultures before and after centrifugation of the 250-ml enrichment broth at 15,900 x g for 10 min at 4 degrees C. The DNA was used as the template in a real-time PCR assay. C. jejuni was detected after 12 h of enrichment from samples inoculated with about 50 CFU/25-g sample. After centrifugation, an enrichment step of 8 h was sufficient to allow detection of pathogen in samples inoculated with 10 CFU/25 g. However, 24 h of enrichment was necessary to detect pathogen in samples inoculated with approximately 1 CFU/25 g. The real-time PCR protocol developed in this study significantly reduced the detection time of C. jejuni in foods.
Collapse
Affiliation(s)
- Tereza C R M Oliveira
- Department of Food and Drug Technology, University of Londrina, Londrina, Parana 86.060-090, Brazil.
| | | | | |
Collapse
|
28
|
Hourfar MK, Michelsen U, Schmidt M, Berger A, Seifried E, Roth WK. High-throughput purification of viral RNA based on novel aqueous chemistry for nucleic acid isolation. Clin Chem 2005; 51:1217-22. [PMID: 15976102 DOI: 10.1373/clinchem.2005.048603] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Extraction protocols using magnetic solid phases offer a high potential for automation. However, commercially available magnetic-bead-based assays either lack the sensitivity required for viral diagnostics or are disproportionately expensive. METHODS We developed an aqueous chemistry for extraction of viral nucleic acids from plasma samples by use of common magnetic silica beads. Nucleic acids were bound to the beads at acidic conditions in the presence of a kosmotropic salt and were eluted at a slightly alkaline pH. The method was implemented on a standard pipetting workstation for fully automated extraction of up to 48 samples of 240 muL plasma in 1 batch. RESULTS The detection limit of the method was comparable to the spin-column-based QIAamp Viral RNA Mini Kit, which relies on chaotropic salts and binding to a silica membrane, as the comparison method. The 95% detection limit was 23.1 IU per PCR for HIV-1 and 10.7 IU per PCR for hepatitis C virus (HCV). Suitability for clinical routine testing was confirmed in a total of 178 HIV-1- or HCV-positive plasma samples. The method linearity (R(2)) was >0.99 for the viruses evaluated. CONCLUSIONS Use of reagents without organic solvents allows simple and cost-effective automation of this method on common pipetting robots with low risk of contamination. Performance characteristics of the novel extraction method make it suitable for use in diagnosis of infectious diseases and viral load determinations.
Collapse
Affiliation(s)
- Michael K Hourfar
- Institute of Transfusion Medicine and Immunohaematology, German Red Cross, Johann Wolfgang Goethe University, Frankfurt, Germany.
| | | | | | | | | | | |
Collapse
|
29
|
Sefers SE, Rickmyre J, Blackman A, Li H, Edwards K, Tang YW. QIAamp MinElute virus kit effectively extracts viral nucleic acids from cerebrospinal fluids and nasopharyngeal swabs. J Clin Virol 2005; 35:141-6. [PMID: 16039902 PMCID: PMC7108269 DOI: 10.1016/j.jcv.2005.05.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2005] [Revised: 05/23/2005] [Accepted: 05/25/2005] [Indexed: 02/04/2023]
Abstract
Background Nucleic acid preparation from a variety of clinical specimens requires efficient target recovery and amplification inhibitor removal and is critical for successful molecular diagnosis. The QIAamp MinElute Virus kit (Qiagen Inc., Valencia, CA) was compared to the two existing methods currently used in our laboratory, IsoQuick (Orca Research Inc., Bothell, WA) for DNA extraction and RNAzol B (Leedo Laboratories Inc., Houston, TX) for RNA extraction, of viral nucleic acids. Study design A total of 150 clinical specimens, including cerebrospinal fluid (CSF) and nasopharyngeal swabs (NPS), were used to determine the extraction efficiency of the MinElute compared to the other two methods. Nucleic acid recovery, hands-on time, turn-around-time and cost were compared across all kits. Results There was complete concordance between the MinElute and IsoQuick/RNAzol kits when herpes simplex virus (HSV), Epstein–Barr virus (EBV), varicella-zoster virus (VZV), influenza A virus or enteroviruses were detected using a colorimetric microtiter plate PCR system. The kits were equivalent in their ability to detect either DNA or RNA with superior ability to recover a high quality and quantity of RNA. With the potential to process larger specimen volumes, the MinElute kit can significantly shorten processing time from 2 h to 50–55 min. Conclusions Although relatively high test kit costs were noted, the MinElute kit provides another rapid and user-friendly specimen processing tool in the diagnostic molecular microbiology laboratory.
Collapse
Affiliation(s)
- Susan E. Sefers
- Department of Pathology, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
| | - Jamie Rickmyre
- Department of Medicine, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
| | - Amondrea Blackman
- Department of Medicine, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
| | - Haijing Li
- Department of Medicine, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
| | - Kathryn Edwards
- Department of Pediatrics, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
| | - Yi-Wei Tang
- Department of Pathology, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
- Department of Medicine, Vanderbilt University School of Medicine, Nashville, TN 37232, USA
- Corresponding author at: Molecular Infectious Disease Laboratory, Vanderbilt University Hospital, 4605 TVC, Nashville, TN 37232-5310, USA. Tel.: +1 615 322 2035; fax: +1 615 343 8420.
| |
Collapse
|
30
|
Namvar L, Olofsson S, Bergström T, Lindh M. Detection and typing of Herpes Simplex virus (HSV) in mucocutaneous samples by TaqMan PCR targeting a gB segment homologous for HSV types 1 and 2. J Clin Microbiol 2005; 43:2058-64. [PMID: 15872222 PMCID: PMC1153722 DOI: 10.1128/jcm.43.5.2058-2064.2005] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Herpes simplex virus types 1 (HSV-1) and 2 (HSV-2) are major causes of mucocutaneous lesions and severe infections of the central nervous system. Here a new semiautomated method for detecting and typing of HSV was used to analyze 479 mucocutaneous swab samples. After DNA extraction using a Magnapure LC robot, a 118-bp segment of the gB region was amplified by real-time PCR utilizing type-specific TaqMan probes to identify HSV-1 or HSV-2. HSV detection in a single well using probes labeled with carboxyfluorescein (FAM) for HSV-1 and JOE (6-carboxy-4',5'-dichloro-2',7'-dimethoxyfluorescein) for HSV-2 had a sensitivity similar to that seen in separate reactions. All but one of 217 samples (99.5%) that had been positive by virus culture were positive by TaqMan PCR, with a correct identification of type in all cases. Out of 262 samples negative by virus culture, 48 (18.3%) were positive by TaqMan PCR, with higher Ct values compared with culture positive samples (P < 0.0001). Overall, the Ct values for HSV-1 were lower than for HSV-2 (mean, 25.5 versus 27.9), but to some extent this could be due to weaker fluorescence by JOE. Lower C(t) values for HSV-1 were seen also in the 202 genital samples (79 HSV-1, 122 HSV-2, 1 HSV-1 and HSV-2), indicating that HSV-1 replicates as well as HSV-2 in the genital area. HSV-1 constituted 40% of genital infections and was associated with lower mean age (29.2 versus 36.4 years), probably reflecting the fact that recurrent genital HSV-1 infections are rare.
Collapse
Affiliation(s)
- Lilly Namvar
- Department of Clinical Virology, Göteborg University, Guldhedsgatan 10B, 413 46 Göteborg, Sweden
| | | | | | | |
Collapse
|
31
|
Issa NC, Espy MJ, Uhl JR, Harmsen WS, Mandrekar JN, Gullerud RE, Davis MD, Smith TF. Comparison of specimen processing and nucleic acid extraction by the swab extraction tube system versus the MagNA Pure LC system for laboratory diagnosis of herpes simplex virus infections by LightCycler PCR. J Clin Microbiol 2005; 43:1059-63. [PMID: 15750060 PMCID: PMC1081253 DOI: 10.1128/jcm.43.3.1059-1063.2005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A total of 563 specimens (234 dermal and 329 genital swabs) from patients suspected of having herpes simplex virus (HSV) infections were processed using two different extraction methods (the MagNA Pure LC system and the swab extraction tube system [SETS]); HSV DNA was amplified by LightCycler PCR. HSV DNA was detected in 157 of 563 specimens (27.9%) processed by the MagNA Pure LC system and in 179 of 563 specimens (31.8%) processed by SETS (P < 0.0001). There was no specimen processed by the MagNA Pure LC extraction method that was positive only for HSV DNA. Of 157 specimens positive by both methods, HSV DNA copy levels were higher (using cycle crossover points [cycle threshold {C(T)}]) with SETS (mean C(T), 25.9 cycles) than with the MagNA Pure LC system (mean C(T), 32.0 cycles) (P < 0.0001). The time to process 32 samples was longer with the MagNA Pure LC extraction system (90 min) than with SETS (35 min). HSV DNA extraction using SETS is faster, less expensive, and more sensitive than the MagNA Pure LC system and could replace the latter for the laboratory diagnosis of HSV infections using LightCycler PCR.
Collapse
Affiliation(s)
- N C Issa
- Division of Clinical Microbiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Hunt I. From gene to protein: a review of new and enabling technologies for multi-parallel protein expression. Protein Expr Purif 2005; 40:1-22. [PMID: 15721767 DOI: 10.1016/j.pep.2004.10.018] [Citation(s) in RCA: 121] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2004] [Revised: 10/07/2004] [Indexed: 10/26/2022]
Abstract
In the post-genomic era, increasingly greater demands and expectations are being placed on protein production laboratories to produce more proteins and in faster timelines. This has been coupled with an exponential increase in the number of requests for the production of proteins which lack structural and functional information. No longer can groups use literature available in the public domain solely to drive their expression strategy, and moreover current expression and concomitant purification strategies clearly do not meet modern-day demands for protein production. This review will therefore attempt to provide a definitive review of current 'best in class' cloning, expression and purification systems, and the adaptations and developments that have been made by laboratories, both academic and industrial, to enhance protein production throughput.
Collapse
Affiliation(s)
- Ian Hunt
- Novartis Horsham Research Centre, Novartis Institutes for Biomedical Research, Wimblehurst Road, Horsham, West Sussex, UK.
| |
Collapse
|
33
|
Mengelle C, Sandres-Sauné K, Miédougé M, Mansuy JM, Bouquies C, Izopet J. Use of two real-time polymerase chain reactions (PCRs) to detect herpes simplex type 1 and 2-DNA after automated extraction of nucleic acid. J Med Virol 2004; 74:459-62. [PMID: 15368516 DOI: 10.1002/jmv.20198] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Herpes simplex virus infections may be diagnosed by several techniques, including conventional cell culture and the polymerase chain reaction (PCR). This prospective study compares the analytical performances and usefulness of an in-house real-time PCR method and the Light Cycler HSV (1/2) detection kit (Roche Diagnostics, Mannheim, Germany). The results of both PCRs were then compared to those obtained by conventional cell culture. A total of 313 samples were tested (70 dermal samples, 81 cerebrospinal fluids (CSF), 47 ocular, 42 anogenital, 34 throat swabs, and 33 oral samples, 3 whole blood, 2 biopsies, and 1 bronchoalveolar lavage). Samples for molecular assays were extracted twice with the MagNa Pure instrument (Roche Molecular Biochemicals, Mannheim, Germany) and tested blind in parallel by the two PCR methods. Most (226) samples were also examined by cell culture. Forty three samples were found positive by both PCRs, whereas 267 were negative. The HSV-1 and -2 typing of positive samples was identical. Three of the samples were positive in the in-house PCR and negative in the Light Cycler HSV (1/2) detection kit. There was no statistically significant difference between the two tests. Only one sample gave an invalid result due to negative PCR and negative internal control result. Seven samples were positive by both real-time PCRs and negative in conventional culture. The PCRs were significantly (P < 0.05) more sensitive. The results show good agreement between the two real-time PCR methods, with the molecular tests being more sensitive than cell culture.
Collapse
Affiliation(s)
- C Mengelle
- Department of Virology, Hôpital Purpan, CHU Toulouse, Toulouse, France.
| | | | | | | | | | | |
Collapse
|
34
|
Ramaswamy M, McDonald C, Smith M, Thomas D, Maxwell S, Tenant-Flowers M, Geretti AM. Diagnosis of genital herpes by real time PCR in routine clinical practice. Sex Transm Infect 2004; 80:406-10. [PMID: 15459412 PMCID: PMC1744886 DOI: 10.1136/sti.2003.008201] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Virus isolation in cell culture is the recognised diagnostic gold standard for genital herpes. Although increasing evidence indicates that polymerase chain reaction (PCR) provides a more rapid and sensitive diagnostic method, its implementation in routine diagnostic settings has been limited by concerns over contamination and cost. OBJECTIVE To evaluate the feasibility of replacing virus culture with PCR for the diagnosis of genital herpes in settings serving large populations of genitourinary medicine (GUM) attendees. METHODS Genital swabs collected from 233 consecutive GUM attendees with suspected genital herpes were tested in parallel by virus culture and automated real time PCR. Three specimen preparation methods were evaluated and the assay reliability was assessed by repeat testing, comparison with a commercially available assay, and herpes simplex virus (HSV) sequence analysis. Probe melting temperatures (Tm) were used to differentiate between HSV types without additional post-PCR steps. RESULTS HSV was detected in 79/233 (34%) samples by virus culture and 132/233 (57%) samples by PCR. PCR significantly increased HSV detection in both early (< 5 days) and late (> or = 5 days) presentations and in both first and recurrent episodes. HSV detection and typing by PCR was achieved within less than 4 hours leading to a significant reduction in labour compared to virus culture. Most specimens (120/132, 91%) were typed as HSV-2. Results were highly reproducible. CONCLUSIONS Real time PCR is a highly reproducible, rapid, and labour efficient method for HSV detection in genital swabs. Its implementation is feasible in routine diagnostic settings.
Collapse
Affiliation(s)
- M Ramaswamy
- Royal Free and University College Medical School, Department of Virology, Hampstead Site, Rowland Hill Street, London NW3 2PF, UK
| | | | | | | | | | | | | |
Collapse
|
35
|
Muller Z, Stelzl E, Bozic M, Haas J, Marth E, Kessler HH. Evaluation of automated sample preparation and quantitative PCR LCx assay for determination of human immunodeficiency virus type 1 RNA. J Clin Microbiol 2004; 42:1439-43. [PMID: 15070986 PMCID: PMC387536 DOI: 10.1128/jcm.42.4.1439-1443.2004] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Efforts have been made to achieve full automation of molecular assays for quantitative detection of human immunodeficiency virus type 1 (HIV-1). In the present study, the Abbott LCx HIV RNA Quantitative assay was evaluated in conjunction with automated HIV-1 RNA extraction on the MagNA Pure LC instrument and compared to the conventional LCx HIV RNA Quantitative assay, which uses a manual nucleic acid extraction protocol. Accuracy, linearity, and interassay and intra-assay variations were determined. The performance of the assay in a routine clinical laboratory was tested with a total of 105 clinical specimens. When the accuracy of the LCx HIV RNA Quantitative assay with the automated sample preparation protocol was tested, all results were found to be within +/- 0.5 log unit of the expected results. Determination of linearity resulted in a quasilinear curve over 3.5 log units. For determination of interassay variation, coefficients of variation were found to be between 21 and 66% for the LCx HIV RNA Quantitative assay with the automated sample preparation protocol and between 10 and 69% for the LCx HIV RNA Quantitative assay with manual sample preparation. For determination of intra-assay variation, coefficients of variation were found to be between 7 and 25% for the LCx HIV RNA Quantitative assay with the automated sample preparation protocol and between 7 and 19% for the LCx HIV RNA Quantitative assay with manual sample preparation. When clinical samples were tested by the LCx HIV RNA Quantitative assay with the automated sample preparation protocol and the results were compared with those of the LCx HIV RNA Quantitative assay with manual sample preparation, 95% of all positive results were found to be within +/- 0.5 log unit. In conclusion, the assay with automated sample preparation proved to be suitable for use in the routine diagnostic laboratory and required significantly less hands-on time.
Collapse
Affiliation(s)
- Zsofia Muller
- Microbiological Laboratory, Regional Public Health Center, H-8000 Szekesfehervar, Hungary
| | | | | | | | | | | |
Collapse
|
36
|
Piiparinen H, Höckerstedt K, Grönhagen-Riska C, Lautenschlager I. Comparison of two quantitative CMV PCR tests, Cobas Amplicor CMV Monitor and TaqMan assay, and pp65-antigenemia assay in the determination of viral loads from peripheral blood of organ transplant patients. J Clin Virol 2004; 30:258-66. [PMID: 15135746 DOI: 10.1016/j.jcv.2003.12.010] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Revised: 12/11/2003] [Accepted: 12/22/2003] [Indexed: 12/17/2022]
Abstract
BACKGROUND Quantitative PCR assays have become the most common methods in the determination of viral load during cytomegalovirus (CMV) infection of transplant patients. However, usually these tests are still quite time-consuming and labor-intensive which diminishes their utility of these tests in routine diagnostic laboratories. OBJECTIVES The objective of this study was to develop a quantitative CMV PCR test which is time-saving and easy to perform for the detection and monitoring of CMV infection of transplant patients. STUDY DESIGN The quantitative real time CMV PCR assay using TaqMan chemistry and an automated sample preparation system, MagNA Pure LC, was developed. The designed quantitative CMV test was compared to commercial quantitative PCR test, Cobas Amplicor Monitor, in the determination of CMV DNA loads in plasma samples of liver and kidney transplant patients. The results were also correlated with the CMV pp65-antigenemia test. The clinical material of 270 blood specimens of transplant patients were tested using these two PCR methods and pp65-antigenemia test in parallel. Plasma samples were used for PCR assays and leucocytes for the antigenemia test. RESULTS The TaqMan assay described was easy to perform, it was rapid (3-4 h) and hands-on time needed for performing the test was short. The detection limit of the assay was 250 copies/ml (cps/ml) plasma and the linear range up to 25,000,000 cps/ml. TaqMan assay was the most sensitive test detecting 92% of the CMV positive findings. Cobas Monitor detected 80% and pp65 test 88% of the positive findings. The correlations between TaqMan and antigenemia assays, and between Cobas Amplicor and antigenemia were statistically significant and high, R = 0.84 (P < 0.0001) and R = 0.80 (P < 0.0001), respectively. Also correlation between two PCR tests was statistically significant (R = 0.64, P < 0.0001). Of the 27 patient studied, 19 demonstrated CMV antigenemia and DNAemia in their blood during the post transplant monitoring. Thirteen of these patients developed a symptomatic CMV infection and were treated with ganciclovir. The peak viral loads of symptomatic patients were statistically higher by all three methods than those of asymptomatic patients. CONCLUSIONS The developed real time TaqMan assay was rapid and easily performed and could be the best alternative for the diagnosis of CMV infection and monitoring of liver and kidney transplant patients.
Collapse
Affiliation(s)
- H Piiparinen
- Department of Virology, Helsinki University Central Hospital and University of Helsinki, Haartmaninkatu 3, FIN-00290 Helsinki, Finland
| | | | | | | |
Collapse
|
37
|
Leb V, Stöcher M, Valentine-Thon E, Hölzl G, Kessler H, Stekel H, Berg J. Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments. J Clin Microbiol 2004; 42:585-90. [PMID: 14766820 PMCID: PMC344446 DOI: 10.1128/jcm.42.2.585-590.2004] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
We report on the development of a fully automated real-time PCR assay for the quantitative detection of hepatitis B virus (HBV) DNA in plasma with EDTA (EDTA plasma). The MagNA Pure LC instrument was used for automated DNA purification and automated preparation of PCR mixtures. Real-time PCR was performed on the LightCycler instrument. An internal amplification control was devised as a PCR competitor and was introduced into the assay at the stage of DNA purification to permit monitoring for sample adequacy. The detection limit of the assay was found to be 200 HBV DNA copies/ml, with a linear dynamic range of 8 orders of magnitude. When samples from the European Union Quality Control Concerted Action HBV Proficiency Panel 1999 were examined, the results were found to be in acceptable agreement with the HBV DNA concentrations of the panel members. In a clinical laboratory evaluation of 123 EDTA plasma samples, a significant correlation was found with the results obtained by the Roche HBV Monitor test on the Cobas Amplicor analyzer within the dynamic range of that system. In conclusion, the newly developed assay has a markedly reduced hands-on time, permits monitoring for sample adequacy, and is suitable for the quantitative detection of HBV DNA in plasma in a routine clinical laboratory.
Collapse
Affiliation(s)
- Victoria Leb
- Institute of Laboratory Medicine, General Hospital Linz, A-4020 Linz, Graz, Austria
| | | | | | | | | | | | | |
Collapse
|
38
|
Hong KM, Najjar H, Hawley M, Press RD. Quantitative real-time PCR with automated sample preparation for diagnosis and monitoring of cytomegalovirus infection in bone marrow transplant patients. Clin Chem 2004; 50:846-56. [PMID: 15010424 DOI: 10.1373/clinchem.2003.026484] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND In bone marrow and stem cell transplant patients, the widespread use of preemptive cytomegalovirus (CMV) antiviral therapy necessitates faster, more precise, and more sensitive quantitative laboratory methods for serial viral load monitoring. METHODS We developed a novel CMV viral load assay using real-time PCR of plasma DNA prepared by an automated robotic workstation. Fluorescent hybridization probes directed at the glycoprotein B (gB) gene (or EcoRI D region) of CMV were used to detect and quantify PCR products. The beta-globin gene was amplified in parallel to control for the efficiency of the extraction and PCR steps. RESULTS The assay was linear (R = 0.999) from a lower detection limit of 125 copies/mL to 5 x 10(9) copies/mL with a PCR efficiency of 1.975 (gB) or 2.02 (EcoRI D). The viral loads determined by PCRs directed at these two different viral targets were no different (n = 53; R = 0.928). The interassay CV was 3.5%, and the intraassay CV was 1-4%. Compared with a commercially available quantitative competitive PCR assay (Roche MONITOR; R = 0.59), the mean CMV viral load by real-time PCR was 3.1 times higher (mean ratio; P = 0.002). The diagnostic sensitivity and specificity of the real-time assay were 96% and 100%, respectively (n = 147), compared with 74% and 98% for a qualitative PCR assay (Roche AMPLICOR). On a subset of samples, the diagnostic sensitivity of viral culture was no greater than 50% (n = 44). Of 1115 clinical referral samples from 252 patients, 10% of the samples and 18% of the patients had low-level CMV viremia (median, 500 copies/mL). In this predominantly (85%) bone marrow transplant testing cohort, serial CMV viral load results were the predominant clinical trigger for the initiation, monitoring, and cessation of preemptive antiviral therapy. CONCLUSIONS The combination of automated DNA preparation and semiautomated real-time fluorescent PCR detection allows for a sensitive, precise, and accurate high-throughput assay of CMV viral load that can be used as the laboratory trigger for preemptive antiviral therapy.
Collapse
Affiliation(s)
- Kyeong Man Hong
- Department of Pathology, Oregon Health & Science University, Portland, OR 97201, USA
| | | | | | | |
Collapse
|
39
|
Germer JJ, Lins MM, Jensen ME, Harmsen WS, Ilstrup DM, Mitchell PS, Cockerill FR, Patel R. Evaluation of the MagNA pure LC instrument for extraction of hepatitis C virus RNA for the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0. J Clin Microbiol 2003; 41:3503-8. [PMID: 12904346 PMCID: PMC179864 DOI: 10.1128/jcm.41.8.3503-3508.2003] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The COBAS AMPLICOR system has played a major role in the transition of molecular diagnostics from research to routine clinical laboratory use by automating the nucleic acid amplification and detection processes. However, sample preparation remains a labor-intensive portion of the procedure. In this study, we evaluated the performance of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 (Roche Molecular Systems, Branchburg, N.J.) following manual hepatitis C virus (HCV) RNA extraction versus automated extraction with the MagNA Pure LC instrument (Roche Applied Science, Indianapolis, Ind.). Parallel replicate testing was performed with standard dilutions of 100, 75, 60, and 0 HCV IU/ml and 153 clinical specimens. An analytical sensitivity of 75 IU/ml was achieved with either the manual or the standard-volume (200 microl) automated extraction methodologies (25 of 26 [96.2%]; 95% confidence interval [95% CI], 80.4 to 99.9), whereas the clinical sensitivity and specificity were both 100% with either extraction method. A large-volume (1 ml) automated extraction method was also evaluated with standard dilutions of 40, 25, 10, and 0 IU/ml and the same 153 clinical specimens. The analytical sensitivity of the COBAS AMPLICOR assay with the large-volume extraction method was 25 HCV IU/ml (26 of 26 [100%]; 95% CI, 86.8 to 100), whereas the clinical sensitivity and specificity were both 100%. The MagNA Pure LC instrument is a versatile, labor-saving platform capable of integration with minimal modification of the existing assay procedure. The increased sensitivity of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 performed in conjunction with large-volume HCV RNA extraction may be important in HCV diagnostic testing as new therapeutic strategies evolve.
Collapse
Affiliation(s)
- Jeffrey J Germer
- Division of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota 55906, USA
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Knepp JH, Geahr MA, Forman MS, Valsamakis A. Comparison of automated and manual nucleic acid extraction methods for detection of enterovirus RNA. J Clin Microbiol 2003; 41:3532-6. [PMID: 12904351 PMCID: PMC179781 DOI: 10.1128/jcm.41.8.3532-3536.2003] [Citation(s) in RCA: 110] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Automated nucleic acid extraction is an attractive alternative to labor-intensive manual methods. We compared two automated methods, the BioRobot M48 instrument (Qiagen, Inc.) and MagNA Pure (Roche Applied Sciences) methods, to two manual methods, the QIAamp Viral RNA Mini kit (Qiagen) and TRIzol (Invitrogen), for the extraction of enterovirus RNA. Analytical sensitivity was assessed by dilution analysis of poliovirus type 2 Sabin in cerebrospinal fluid. The sensitivity of PCR was equivalent after RNA extraction with QIAamp, BioRobot M48, and MagNA Pure. All 18 replicates of 100 PFU/ml were detected after extraction by the four methods. Fewer replicates of each successive dilution were detected after extraction by each method. At 10(-1) PFU/ml, 17 of 18 replicates were positive by QIAamp, 15 of 18 replicates were positive by BioRobot M48, and 12 of 18 replicates were positive by MagNA Pure; at 10(-2) PFU/ml, 4 of 17 replicates were positive by QIAamp, 2 of 18 replicates were positive by BioRobot M48, and 0 of 18 replicates were positive by MagNA Pure. At 10(-3) PFU/ml, no replicates were detected. Evaluation of TRIzol was discontinued after nine replicates due to a trend of lower sensitivity (at 10(-3) PFU/ml eight of nine replicates were positive at 100 PFU/ml, four of nine replicates were positive at 10(-1) PFU/ml, and zero of nine replicates were positive at 10(-2) PFU/ml). Concordant results were obtained in 24 of 28 clinical specimens after extraction by all methods. No evidence of contamination was observed after extraction by automated instruments. The data indicate that the sensitivity of enterovirus PCR is largely similar after extraction by QIAamp, BioRobot M48, and MagNA Pure; a trend of decreased sensitivity was observed after TRIzol extraction. However, the results of enterovirus PCR were largely concordant in patient samples, indicating that the four extraction methods are suitable for detection of enteroviruses in clinical specimens.
Collapse
Affiliation(s)
- Julia H Knepp
- Department of Pathology, The Johns Hopkins Medical Institutions, Baltimore, Maryland 21287-7093, USA
| | | | | | | |
Collapse
|
41
|
Lee BG, Fiebelkorn KR, Caliendo AM, Nolte FS. Development and verification of an automated sample processing protocol for quantitation of human immunodeficiency virus type 1 RNA in plasma. J Clin Microbiol 2003; 41:2062-7. [PMID: 12734249 PMCID: PMC154724 DOI: 10.1128/jcm.41.5.2062-2067.2003] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We developed and verified an automated sample processing protocol for use with the AMPLICOR HIV-1 MONITOR test, version 1.5 (Roche Diagnostics, Indianapolis, Ind.). The automated method uses the MagNA Pure LC instrument and total nucleic acid reagents (Roche Applied Science, Indianapolis, Ind.) to extract human immunodeficiency virus type 1 (HIV-1) RNA from plasma specimens. We compared the HIV-1 load results for a dilution series (1 to 5 nominal log(10) copies/ml) and 175 clinical specimens processed by the automated method to those for the same samples processed by the manual methods specified by the manufacturer. The sensitivity, dynamic range, and precision of the viral load assay obtained by automated processing of specimens were similar to those obtained by an ultrasensitive manual processing method. The results were highly correlated (R(2), 0.95), and were in close agreement, with a mean difference of 0.09 log(10) (standard deviation, 0.292). The limits of agreement were +/-0.58 log(10) for results for samples processed by both the manual and the automated methods. These performance characteristics were achieved with a smaller sample volume (200 versus 500 microl) and without a high-speed centrifugation step and required only 15 min of labor for a batch of 32 samples. In conclusion, the automated sample preparation protocol can replace both the standard and the ultrasensitive manual methods used with the AMPLICOR HIV-1 MONITOR test and can substantially reduce the labor associated with this test.
Collapse
Affiliation(s)
- Brenda G Lee
- Clinical Laboratories, Emory University Hospital, Atlanta, Georgia 30322, USA
| | | | | | | |
Collapse
|
42
|
Ellis JS, Alvarez-Aguero A, Gregory V, Lin YP, Hay A, Zambon MC. Influenza AH1N2 viruses, United Kingdom, 2001-02 influenza season. Emerg Infect Dis 2003; 9:304-10. [PMID: 12643824 PMCID: PMC2958547 DOI: 10.3201/eid0903.020404] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
During the winter of 2001-02, influenza AH1N2 viruses were detected for the first time in humans in the U.K. The H1N2 viruses co-circulated with H3N2 viruses and a very small number of H1N1 viruses and were isolated in the community and hospitalized patients, predominantly from children <15 years of age. Characterization of H1N2 viruses indicated that they were antigenically and genetically homogeneous, deriving the hemagglutinin (HA) gene from recently circulating A/New Caledonia/20/99-like H1N1 viruses, whereas the other seven genes originated from recently circulating H3N2 viruses. Retrospective reverse transcription-polymerase chain reaction analysis of influenza A H1 viruses isolated in the U.K. during the previous winter identified a single H1N2 virus, isolated in March 2001, indicating that H1N2 viruses did not widely circulate in the U.K. before September 2001. The reassortment event is estimated to have occurred between 1999 and early 2001, and the emergence of H1N2 viruses in humans reinforces the need for frequent surveillance of circulating viruses.
Collapse
Affiliation(s)
- Joanna S Ellis
- Central Public Health Laboratory, Colindale, London, United Kingdom.
| | | | | | | | | | | |
Collapse
|
43
|
Hölzl G, Stöcher M, Leb V, Stekel H, Berg J. Entirely automated quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma by using the ultrasensitive COBAS AMPLICOR HIV-1 monitor test and RNA purification on the MagNA pure LC instrument. J Clin Microbiol 2003; 41:1248-51. [PMID: 12624059 PMCID: PMC150272 DOI: 10.1128/jcm.41.3.1248-1251.2003] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The ultrasensitive COBAS AMPLICOR HIV-1 Monitor test was complemented with automated RNA purification on the MagNA Pure LC instrument. This enabled entirely automated ultrasensitive assessment of viral loads in human immunodeficiency virus type 1 (HIV-1)-infected individuals. The detection limit of the fully automated assay and the viral load measurements in 80 clinical samples were found to be in good agreement with those of the conventional ultrasensitive COBAS AMPLICOR HIV-1 Monitor test. The fully automated assay showed markedly reduced hands-on time and was found to be suitable for the routine assessment of HIV-1 viral loads in a clinical diagnostic laboratory.
Collapse
Affiliation(s)
- Gabriele Hölzl
- Institute of Laboratory Medicine, General Hospital Linz, A-4020 Linz, Austria
| | | | | | | | | |
Collapse
|
44
|
van Doornum GJJ, Guldemeester J, Osterhaus ADME, Niesters HGM. Diagnosing herpesvirus infections by real-time amplification and rapid culture. J Clin Microbiol 2003; 41:576-80. [PMID: 12574249 PMCID: PMC149665 DOI: 10.1128/jcm.41.2.576-580.2003] [Citation(s) in RCA: 208] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Procedures using real-time technique were developed to demonstrate the presence of herpes simplex virus type 1 (HSV-1) and HSV-2, varicella zoster virus (VZV), and cytomegalovirus (CMV) in miscellaneous clinical specimens. The assays were compared to rapid culture using centrifugation followed by detection with monoclonal antibodies. A total of 711 consecutive samples were collected from different patient groups. Throat swabs were obtained from transplant patients; dermal or oral specimens were collected from patients suspected for VZV or HSV infection. Genital specimens were taken from patients who attended the Clinic for Sexually Transmitted Diseases at the Dijkzigt Hospital Rotterdam presenting with symptoms of a primary genital ulcer. Nucleic acid extraction was carried out using a MagnaPure LC instrument. The amplification steps were performed on the ABI Prism 7700 sequence detection system. To monitor the process of extraction and amplification, a universal control consisting of seal herpesvirus type 1 (PhHV-1) was added to the clinical specimens. By culture 127 of 668 (19%) samples were positive for HSV-1, 72 of 668 (10.8%) specimens were positive for HSV-2, and 17 of 366 (4.6%) were positive for VZV. Using real-time amplification the numbers of positive specimens were 143 of 668 (21.4%), 97 of 668 (14.5%), and 27 of 366 (7.4%), respectively. Eighty-six specimens were tested for CMV, 12 (14.0%) were positive by culture, and 17 (19.8%) were positive by real-time PCR. The clinical data of the patients with discrepant results were reviewed thoroughly. In all cases the patients with only real-time PCR-positive results could be considered as truly infected. We concluded that the real-time amplification technique is suitable for the detection of human herpesvirus infection. It offers a semiquantitative and reliable assay with a quick result that is more sensitive than rapid culture, especially for the diagnosis of HSV-2 and VZV infections.
Collapse
|
45
|
Versalovic J, Lupski JR. Molecular detection and genotyping of pathogens: more accurate and rapid answers. Trends Microbiol 2002; 10:S15-21. [PMID: 12377563 DOI: 10.1016/s0966-842x(02)02438-1] [Citation(s) in RCA: 93] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Rapid molecular methods have enhanced the capabilities of laboratories to identify and characterize microbial pathogens in greater detail. Nucleic acid amplification strategies and advances in amplicon detection have been key aspects in the progress of molecular microbiology. Sophisticated new amplification-detection combinations are resulting in many applications in laboratory testing for infectious diseases. These applications include qualitative detection, sub-species-level DNA fingerprinting, molecular resistance testing and genotyping, and quantitative (viral load) testing. When applied selectively in the laboratory, these applications can enhance diagnostic approaches and clinical management and will probably evolve into standard laboratory and point-of-care testing protocols.
Collapse
Affiliation(s)
- James Versalovic
- Dept of Pathology, Baylor College of Medicine, Houston, TX 77030, USA.
| | | |
Collapse
|
46
|
Abstract
The past decade has seen tremendous developments in molecular diagnostic techniques. In particular, the development of PCR technology has enabled rapid and sensitive viral diagnostic tests to influence patient management. Molecular methods used directly on clinical material have an important role to play in the diagnosis and surveillance of influenza viruses. Molecular diagnostic tests that allow timely and accurate detection of influenza are already implemented in many laboratories. The combination of automated purification of nucleic acids with real-time PCR should enable even more rapid identification of viral pathogens such as influenza viruses in clinical material. The recent development of DNA microarrays to identify either multiple gene targets from a single pathogen, or multiple pathogens in a single sample has the capacity to transform influenza diagnosis. While molecular methods will not replace cell culture for the provision of virus isolates for antigenic characterisation, they remain invaluable in assisting our understanding of the epidemiology of influenza viruses.
Collapse
Affiliation(s)
- Joanna S Ellis
- Respiratory Virus Unit, Enteric, Respiratory and Neurological Virus Laboratory, Public Health Laboratory Service, Central Public Health Laboratory, 61 Colindale Avenue, Colindale, London NW9 5HT, UK.
| | | |
Collapse
|
47
|
Fiebelkorn KR, Lee BG, Hill CE, Caliendo AM, Nolte FS. Clinical Evaluation of an Automated Nucleic Acid Isolation System. Clin Chem 2002. [DOI: 10.1093/clinchem/48.9.1613] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Kristin R Fiebelkorn
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, GA 30322
| | - Brenda G Lee
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, GA 30322
| | - Charles E Hill
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, GA 30322
| | - Angela M Caliendo
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, GA 30322
| | - Frederick S Nolte
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, GA 30322
| |
Collapse
|
48
|
Affiliation(s)
- Sheri M Williams
- ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT 84108
| | - Cindy A Meadows
- ARUP Laboratories, 500 Chipeta Way, Salt Lake City, UT 84108
| | - Elaine Lyon
- ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT 84108
- Department of Pathology, University of Utah School of Medicine, 50 North Medical Dr., Salt Lake City, UT 84132
| |
Collapse
|
49
|
Espy MJ, Uhl JR, Sloan LM, Rosenblatt JE, Cockerill FR, Smith TF. Detection of vaccinia virus, herpes simplex virus, varicella-zoster virus, and Bacillus anthracis DNA by LightCycler polymerase chain reaction after autoclaving: implications for biosafety of bioterrorism agents. Mayo Clin Proc 2002; 77:624-8. [PMID: 12108599 DOI: 10.4065/77.7.624] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To determine whether autoclaving suspensions of vaccinia virus, herpes simplex virus (HSV), varicella-zoster virus (VZV), and Bacillus anthracis inactivate infectivity of these agents but allow detection of target DNA by LightCycler polymerase chain reaction (PCR). MATERIAL AND METHODS Swabs were inserted into tubes containing serial 10-fold dilutions (10(-1) to 10(-5); 500 microL; 6 samples per dilution) of vaccinia virus, HSV, VZV, or a single suspension of 10(8) colony-forming units of B anthracis (2 samples). One half of the samples were autoclaved, and the remainder were not. An aliquot of each not autoclaved sample served as a control for infectivity. RESULTS Autoclaving swabs saturated with suspensions of vaccinia virus, HSV, or VZV eliminated the infectivity of these agents; however, DNA was detectable in most autoclaved samples in dilutions of 10(-1) to 10(-4) by LightCycler PCR. All not autoclaved specimens were detected by culture (infectivity) except for VZV and, in most dilutions of 10(-1) to 10(-3), by assay of target DNA by LightCycler PCR. Similarly positive results were obtained for PCR assessment of sporulated B anthracis. CONCLUSIONS Standard autoclaving procedures eliminated the infectivity of viruses (and B anthracis), but target DNA was often retained for detection by LightCycler PCR. Current recommendations indicate that the laboratory diagnosis of smallpox virus infection be performed only within Biosafety Level 4 facilities. We suggest that, in addition to the requirement for immediate coordination with public health officials, the federal government consider expanding the existing guidelines for processing these specimens to encourage immediate collection, autoclaving, and testing by LightCycler PCR to differentiate smallpox virus from other dermal pathogens such as HSV and VZV by specific qualified laboratories.
Collapse
Affiliation(s)
- Mark J Espy
- Division of Clinical Microbiology, Mayo Clinic, Rochester, MN 55905, USA
| | | | | | | | | | | |
Collapse
|
50
|
Espy MJ, Cockerill III FR, Meyer RF, Bowen MD, Poland GA, Hadfield TL, Smith TF. Detection of smallpox virus DNA by LightCycler PCR. J Clin Microbiol 2002; 40:1985-8. [PMID: 12037052 PMCID: PMC130682 DOI: 10.1128/jcm.40.6.1985-1988.2002] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A 300-bp plasmid fragment of the hemagglutinin gene was used as target DNA to develop a rapid real-time LightCycler (Roche Applied Science, Indianapolis, Ind.) PCR assay for laboratory detection of smallpox virus. PCR primers and probes were designed specifically for detection of smallpox virus DNA, but all viruses of the genus Orthopoxvirus tested could be detected by use of the hemagglutinin gene target sequence. Base pair mismatches in the 204-bp amplicon allowed discrimination of cowpox virus (melting temperature [T(m)], 56.40 degrees C), monkeypox virus (T(m), 56.24 degrees C), and vaccinia virus (T(m), 56.72 degrees C), including the Dryvax vaccine strain, from smallpox virus (T(m), 62.45 degrees C) by melting curve analysis. The analytical sensitivity was 5 to 10 copies of target DNA per sample. The assay was specific for members of the genus Orthopoxvirus; the DNAs of herpes simplex virus and varicella-zoster virus were not detected by the smallpox virus LightCycler PCR.
Collapse
Affiliation(s)
- Mark J Espy
- Division of Clinical Microbiology, Mayo Clinic and Foundation, Rochester, MN 55905, USA
| | | | | | | | | | | | | |
Collapse
|