1
|
Wieting W, Bengel FM, Diekmann J. Comparison of global and regional myocardial blood flow quantification using dynamic solid-state detector SPECT and Tc-99 m-sestamibi or Tc-99 m-tetrofosmin in a routine clinical setting. Int J Cardiovasc Imaging 2025; 41:537-548. [PMID: 39885112 PMCID: PMC11880047 DOI: 10.1007/s10554-025-03339-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Accepted: 01/17/2025] [Indexed: 02/01/2025]
Abstract
Solid-state detector single photon emission computed tomography (SPECT) enables the acquisition of dynamic data for calculation of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Here, we report about our experiences on routine clinical use and robustness using Tc-99 m-sestamibi and Tc-99 m-tetrofosmin. 307 patients underwent dynamic list-mode myocardial perfusion imaging (MPI) and standard static MPI for clinical workup of coronary artery disease on a dedicated cardiac SPECT camera. After exclusion of 33 scans, 274 scans were eligible for MBF and MFR calculation using a 1-tissue-compartment model. Attenuation correction was performed for all patients using an external computed tomogram. Patients underwent stress-only scans, both stress and rest scans or rest-only scans using Tc-99 m-tetrofosmin or Tc-99 m-sestamibi. 30 patients without known cardiovascular comorbidities and without perfusion defect on static scans were compared in a sub analysis. Global stress myocardial blood flow (MBF) was significantly higher than rest MBF (2.3 vs. 1.1 ml/min/g; p < 0.001), and showed a high variability among individuals. Global myocardial flow reserve (MFR) was 2.1 (range 0.5-7.8). An analysis of 30 patients without known cardiovascular comorbidities yielded similar stress MBF measures for Tc-99 m-sestamibi and Tc-99 m-tetrofosmin (3.1 ± 1.2 vs. 2.8 ± 0.9 ml/min/g; p = 0.429). The use of attenuation correction lead to systematically lower MBF measures. Patients who underwent a one-day protocol had notably higher rest MBF (1.2 ± 0.5 vs. 1.0 ± 0.46 ml/min/g; p = 0.009) and consequently a lower MFR. Summed defect scores from standard static scans and presence of cardiovascular comorbidities negatively impacted MBF and MFR. Quantitative SPECT MBF and MFR in a clinical routine setting yields flow measures in range of expectation at an albeit wide range and is comprehensibly linked with results from standard static scan and patients history of cardiovascular diseases. Use of one-day protocols and attenuation correction systematically alters quantitative results. However, SPECT-derived MBF and MFR lack clinical reliability due to less validated reference ranges and high inter-individual variability.
Collapse
Affiliation(s)
- Wiebke Wieting
- Department of Nuclear Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Frank M Bengel
- Department of Nuclear Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Johanna Diekmann
- Department of Nuclear Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
| |
Collapse
|
2
|
Nakahara T, Fujimoto S, Jinzaki M. Molecular imaging of cardiovascular disease: Current status and future perspective. J Cardiol 2025:S0914-5087(25)00017-6. [PMID: 39922562 DOI: 10.1016/j.jjcc.2025.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2024] [Revised: 01/15/2025] [Accepted: 01/28/2025] [Indexed: 02/10/2025]
Abstract
Advancements in knowledge of cardiovascular disease, pharmacology, and chemistry have led to the development of newer radiopharmaceuticals and targets for new and more suitable molecules. Molecular imaging encompasses multiple imaging techniques for identifying the characteristics of key components involved in disease. Despite its limitations in spatial resolution, the affinity for key molecules compensates for disadvantages in diagnosing diseases and elucidating their pathophysiology. This review introduce established molecular tracers involved in clinical practice and emerging tracers already applied in clinical studies, classifying the key component in A: artery, specifically those vulnerable plaque (A-I) inflammatory cells [18F-FDG]; A-II) lipid/fatty acid; A-III) hypoxia; A-IV) angiogenesis; A-V) protease [18F/68Ga-FAPI]; A-VI) thrombus/hemorrhage; A-VII) apoptosis and A-VIII) microcalcification [18F-NaF]) and B: myocardium, including myocardial ischemia, infarction and myocardiopathy (B-I) myocardial ischemia; B-II) myocardial infarction (myocardial damage and fibrosis); B-III) myocarditis and endocarditis; B-IV) sarcoidosis; B-V) amyloidosis; B-VI) metabolism; B-VII) innervation imaging). In addition to cardiovascular-specific tracers tested in animal models, many radiotracers may have been developed in other areas, such as oncology imaging or neuroimaging. While this review does not cover all available tracers, some of them hold potential for future use assessing cardiovascular disease. Advances in molecular biology, pharmaceuticals, and imaging sciences will facilitate the identification of precise disease mechanisms, enabling precise diagnoses, better assessment of disease status, and enhanced therapeutic evaluation in this multi-modality era.
Collapse
Affiliation(s)
- Takehiro Nakahara
- Department of Radiology, Keio University School of Medicine, Tokyo, Japan.
| | - Shinichiro Fujimoto
- Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
3
|
Krajewski S, Steczek L, Gotowicz K, Karczmarczyk U, Towpik J, Witkowska-Patena E, Łyczko K, Mazur M, Kozanecki P, Włostowska J, Knuuti J, Dziuk M, Garnuszek P, Kozanecki C. Preclinical evaluation of [ 18F]SYN1 and [ 18F]SYN2, novel radiotracers for PET myocardial perfusion imaging. EJNMMI Res 2024; 14:63. [PMID: 38976101 PMCID: PMC11231114 DOI: 10.1186/s13550-024-01122-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Accepted: 06/20/2024] [Indexed: 07/09/2024] Open
Abstract
BACKGROUND Positron emission tomography (PET) is now an established diagnostic method for myocardial perfusion imaging (MPI) in coronary artery disease, which is the main cause of death globally. The available tracers show several limitations, therefore, the 18F-labelled tracer is in high demand nowadays. The preclinical studies on normal Wistar rats aimed to characterise two potential, novel radiotracers, [18F]SYN1 and [18F]SYN2, to evaluate which is a better candidate for PET MPI cardiotracer. RESULTS The dynamic microPET images showed rapid myocardial uptake for both tracers. However, the uptake was higher and also stable for [18F]SYN2, with an average standardized uptake value of 3.8. The biodistribution studies confirmed that [18F]SYN2 uptake in the cardiac muscle was high and stable (3.02%ID/g at 15 min and 2.79%ID/g at 6 h) compared to [18F]SYN1 (1.84%ID/g at 15 min and 0.32%ID/g at 6 h). The critical organs determined in dosimetry studies were the small intestine and the kidneys. The estimated effective dose for humans was 0.00714 mSv/MBq for [18F]SYN1 and 0.0109 mSv/MBq for [18F]SYN2. The tested dose level of 2 mg/kg was considered to be the No Observed Adverse Effect Level (NOAEL) for both candidates. The better results were achieved for [18F]SYN2, therefore, further preclinical studies were conducted only for this tracer. Radioligand binding assays showed significant responses in 3 from 68 assays: muscarinic acetylcholine M1 and M2 receptors and potassium channel hERG. The compound was mostly metabolised via an oxidative N-dealkylation, while the fluor substituent was not separated from the molecule. CONCLUSION [18F]SYN2 showed a favourable pharmacodynamic and pharmacokinetic profile, which enabled a clear visualization of the heart in microPET. The compound was well-tolerated in studies in normal rats with moderate radiation exposure. The results encourage further exploration of [18F]SYN2 in clinical studies.
Collapse
Affiliation(s)
| | - Lukasz Steczek
- Research & Development Centre, Synektik SA, Warsaw, Poland
| | - Karina Gotowicz
- Research & Development Centre, Synektik SA, Warsaw, Poland
- Department of Chemistry, University of Warsaw, Warsaw, Poland
| | - Urszula Karczmarczyk
- Radioisotope Centre POLATOM, National Centre for Nuclear Research, Otwock, Poland
| | - Joanna Towpik
- Research & Development Centre, Synektik SA, Warsaw, Poland
| | - Ewa Witkowska-Patena
- Nuclear Medicine Department, Military Institute of Medicine - National Research Institute, Warsaw, Poland
- Affidea Poland, Warsaw, Poland
| | | | - Maciej Mazur
- Department of Chemistry, University of Warsaw, Warsaw, Poland
| | | | | | - Juhani Knuuti
- Turku PET Centre, Turku University Hospital and University of Turku, Turku, Finland
- Department of Clinical Physiology, Nuclear Medicine, and PET, Turku University Hospital, Turku, Finland
| | - Mirosław Dziuk
- Nuclear Medicine Department, Military Institute of Medicine - National Research Institute, Warsaw, Poland
- Affidea Poland, Warsaw, Poland
| | - Piotr Garnuszek
- Radioisotope Centre POLATOM, National Centre for Nuclear Research, Otwock, Poland
| | | |
Collapse
|
4
|
Akbari B, Huber BR, Sherman JH. Unlocking the Hidden Depths: Multi-Modal Integration of Imaging Mass Spectrometry-Based and Molecular Imaging Techniques. Crit Rev Anal Chem 2023; 55:109-138. [PMID: 37847593 DOI: 10.1080/10408347.2023.2266838] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2023]
Abstract
Multimodal imaging (MMI) has emerged as a powerful tool in clinical research, combining different imaging modes to acquire comprehensive information and enabling scientists and surgeons to study tissue identification, localization, metabolic activity, and molecular discovery, thus aiding in disease progression analysis. While multimodal instruments are gaining popularity, challenges such as non-standardized characteristics, custom software, inadequate commercial support, and integration issues with other instruments need to be addressed. The field of multimodal imaging or multiplexed imaging allows for simultaneous signal reproduction from multiple imaging strategies. Intraoperatively, MMI can be integrated into frameless stereotactic surgery. Recent developments in medical imaging modalities such as magnetic resonance imaging (MRI), and Positron Emission Topography (PET) have brought new perspectives to multimodal imaging, enabling early cancer detection, molecular tracking, and real-time progression monitoring. Despite the evidence supporting the role of MMI in surgical decision-making, there is a need for comprehensive studies to validate and perform integration at the intersection of multiple imaging technologies. They were integrating mass spectrometry-based technologies (e.g., imaging mass spectrometry (IMS), imaging mass cytometry (IMC), and Ion mobility mass spectrometry ((IM-IM) with medical imaging modalities, offering promising avenues for molecular discovery and clinical applications. This review emphasizes the potential of multi-omics approaches in tissue mapping using MMI integrated into desorption electrospray ionization (DESI) and matrix-assisted laser desorption ionization (MALDI), allowing for sequential analyses of the same section. By addressing existing knowledge gaps, this review encourages future research endeavors toward multi-omics approaches, providing a roadmap for future research and enhancing the value of MMI in molecular pathology for diagnosis.
Collapse
Affiliation(s)
- Behnaz Akbari
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Bertrand Russell Huber
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
- Boston University Alzheimer's Disease and CTE Center, Boston University School of Medicine, Boston, Massachusetts, USA
- Department of Neurology, Boston University School of Medicine, Boston, Massachusetts, USA
- US Department of Veteran Affairs, VA Boston Healthcare System, Boston, Massachusetts USA
- US Department of Veterans Affairs, National Center for PTSD, Boston, Massachusetts USA
| | - Janet Hope Sherman
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| |
Collapse
|
5
|
Perrone MA, Cimini A, Ricci M, Pizzoferro M, Garganese MC, Raponi M, Schillaci O. Myocardial Functional Imaging in Pediatric Nuclear Cardiology. J Cardiovasc Dev Dis 2023; 10:361. [PMID: 37754790 PMCID: PMC10531976 DOI: 10.3390/jcdd10090361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 08/03/2023] [Accepted: 08/22/2023] [Indexed: 09/28/2023] Open
Abstract
The role of nuclear medicine in pediatric cardiology has grown rapidly over the years, providing useful functional and prognostic information and playing a complementary role to morphological imaging in the evaluation of myocardial perfusion, cardiovascular inflammation and infections, and cardiac sympathetic innervation. The aim of this narrative review is to summarize and highlight the most important evidence on pediatric nuclear cardiology, describing clinical applications and the possibilities, advantages, and limitations of nuclear medicine techniques. Moreover, a special focus will be given to the minimization of radiation exposure in pediatric nuclear cardiology imaging, a critical topic in children.
Collapse
Affiliation(s)
- Marco Alfonso Perrone
- Department of Pediatric Cardiology and Cardiac Surgery, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
- Division of Cardiology and CardioLab, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy
| | - Andrea Cimini
- Nuclear Medicine Unit, St. Salvatore Hospital, 67100 L’Aquila, Italy
| | - Maria Ricci
- Nuclear Medicine Unit, Cardarelli Hospital, 86100 Campobasso, Italy
| | - Milena Pizzoferro
- Division of Nuclear Medicine, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
| | | | - Massimiliano Raponi
- Health Directorate, Bambino Gesù Children’s Hospital IRCCS, 00165 Rome, Italy
| | - Orazio Schillaci
- Department of Biomedicine and Prevention, University of Rome Tor Vergata, 00133 Rome, Italy
| |
Collapse
|
6
|
Wang X, Chen C, Yan J, Xu Y, Pan D, Wang L, Yang M. Druggability of Targets for Diagnostic Radiopharmaceuticals. ACS Pharmacol Transl Sci 2023; 6:1107-1119. [PMID: 37588760 PMCID: PMC10425999 DOI: 10.1021/acsptsci.3c00081] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Indexed: 08/18/2023]
Abstract
Targets play an indispensable and pivotal role in the development of radiopharmaceuticals. However, the initial stages of drug discovery projects are often plagued by frequent failures due to inadequate information on druggability and suboptimal target selection. In this context, we aim to present a comprehensive review of the factors that influence target druggability for diagnostic radiopharmaceuticals. Specifically, we explore the crucial determinants of target specificity, abundance, localization, and positivity rate and their respective implications. Through a detailed analysis of existing protein targets, we elucidate the significance of each factor. By carefully considering and balancing these factors during the selection of targets, more efficacious and targeted radiopharmaceuticals are expected to be designed for the diagnosis of a wide range of diseases in the future.
Collapse
Affiliation(s)
- Xinyu Wang
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
- School
of Pharmacy, Nanjing Medical University, Nanjing 211166, PR China
| | - Chongyang Chen
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
| | - Junjie Yan
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
- School
of Pharmacy, Nanjing Medical University, Nanjing 211166, PR China
| | - Yuping Xu
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
- School
of Pharmacy, Nanjing Medical University, Nanjing 211166, PR China
| | - Donghui Pan
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
| | - Lizhen Wang
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
| | - Min Yang
- NHC
Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular
Nuclear Medicine, Jiangsu Institute of Nuclear
Medicine, Wuxi 214063, PR China
- School
of Pharmacy, Nanjing Medical University, Nanjing 211166, PR China
| |
Collapse
|
7
|
Chen L, Gao Y, Ge J, Zhou Y, Yang Z, Li C, Huang B, Lu K, Kou D, Zhou D, Chen C, Wang S, Wu S, Zeng J, Huang G, Gao M. A clinically translatable kit for MRI/NMI dual-modality nanoprobes based on anchoring group-mediated radiolabeling. NANOSCALE 2023; 15:3991-3999. [PMID: 36723217 DOI: 10.1039/d2nr05988f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Magnetic resonance imaging (MRI)/nuclear medicine imaging (NMI) dual-modality imaging based on radiolabeled nanoparticles has been increasingly exploited for accurate diagnosis of tumor and cardiovascular diseases by virtue of high spatial resolution and high sensitivity. However, significant challenges exist in pursuing truly clinical applications, including massive preparation and rapid radiolabeling of nanoparticles. Herein, we report a clinically translatable kit for the convenient construction of MRI/NMI nanoprobes relying on the flow-synthesis and anchoring group-mediated radiolabeling (LAGMERAL) of iron oxide nanoparticles. First, homogeneous iron oxide nanoparticles with excellent performance were successfully obtained on a large scale by flow synthesis, followed by the surface anchoring of diphosphonate-polyethylene glycol (DP-PEG) to simultaneously render the underlying nanoparticles biocompatible and competent in robust labeling of radioactive metal ions. Moreover, to enable convenient and safe usage in clinics, the DP-PEG modified nanoparticle solution was freeze-dried and sterilized to make a radiolabeling kit followed by careful evaluations of its in vitro and in vivo performance and applicability. The results showed that 99mTc labeled nanoprobes are effectively obtained with a labeling yield of over 95% in 30 minutes after simply injecting Na[99mTcO4] solution into the kit. In addition, the Fe3O4 nanoparticles sealed in the kit can well stand long-term storage even for 300 days without deteriorating the colloidal stability and radiolabeling yield. Upon intravenous injection of the as-prepared radiolabeled nanoprobes, high-resolution vascular images of mice were obtained by vascular SPECT imaging and magnetic resonance angiography, demonstrating the promising clinical translational value of our radiolabeling kit.
Collapse
Affiliation(s)
- Lei Chen
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Yun Gao
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Jianxian Ge
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Yi Zhou
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Zhe Yang
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Cang Li
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Baoxing Huang
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Kuan Lu
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Dandan Kou
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Dandan Zhou
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Can Chen
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Sixia Wang
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Shuwang Wu
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Jianfeng Zeng
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
| | - Gang Huang
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Mingyuan Gao
- Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
- The Second Affiliated Hospital of Soochow University, Suzhou 215004, China
| |
Collapse
|
8
|
Crișan G, Moldovean-Cioroianu NS, Timaru DG, Andrieș G, Căinap C, Chiș V. Radiopharmaceuticals for PET and SPECT Imaging: A Literature Review over the Last Decade. Int J Mol Sci 2022; 23:5023. [PMID: 35563414 PMCID: PMC9103893 DOI: 10.3390/ijms23095023] [Citation(s) in RCA: 118] [Impact Index Per Article: 39.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 04/23/2022] [Accepted: 04/28/2022] [Indexed: 02/04/2023] Open
Abstract
Positron emission tomography (PET) uses radioactive tracers and enables the functional imaging of several metabolic processes, blood flow measurements, regional chemical composition, and/or chemical absorption. Depending on the targeted processes within the living organism, different tracers are used for various medical conditions, such as cancer, particular brain pathologies, cardiac events, and bone lesions, where the most commonly used tracers are radiolabeled with 18F (e.g., [18F]-FDG and NA [18F]). Oxygen-15 isotope is mostly involved in blood flow measurements, whereas a wide array of 11C-based compounds have also been developed for neuronal disorders according to the affected neuroreceptors, prostate cancer, and lung carcinomas. In contrast, the single-photon emission computed tomography (SPECT) technique uses gamma-emitting radioisotopes and can be used to diagnose strokes, seizures, bone illnesses, and infections by gauging the blood flow and radio distribution within tissues and organs. The radioisotopes typically used in SPECT imaging are iodine-123, technetium-99m, xenon-133, thallium-201, and indium-111. This systematic review article aims to clarify and disseminate the available scientific literature focused on PET/SPECT radiotracers and to provide an overview of the conducted research within the past decade, with an additional focus on the novel radiopharmaceuticals developed for medical imaging.
Collapse
Affiliation(s)
- George Crișan
- Faculty of Physics, Babeş-Bolyai University, Str. M. Kogălniceanu 1, 400084 Cluj-Napoca, Romania; (G.C.); (N.S.M.-C.); (D.-G.T.)
- Department of Nuclear Medicine, County Clinical Hospital, Clinicilor 3-5, 400006 Cluj-Napoca, Romania;
| | | | - Diana-Gabriela Timaru
- Faculty of Physics, Babeş-Bolyai University, Str. M. Kogălniceanu 1, 400084 Cluj-Napoca, Romania; (G.C.); (N.S.M.-C.); (D.-G.T.)
| | - Gabriel Andrieș
- Department of Nuclear Medicine, County Clinical Hospital, Clinicilor 3-5, 400006 Cluj-Napoca, Romania;
| | - Călin Căinap
- The Oncology Institute “Prof. Dr. Ion Chiricuţă”, Republicii 34-36, 400015 Cluj-Napoca, Romania;
| | - Vasile Chiș
- Faculty of Physics, Babeş-Bolyai University, Str. M. Kogălniceanu 1, 400084 Cluj-Napoca, Romania; (G.C.); (N.S.M.-C.); (D.-G.T.)
- Institute for Research, Development and Innovation in Applied Natural Sciences, Babeș-Bolyai University, Str. Fântânele 30, 400327 Cluj-Napoca, Romania
| |
Collapse
|
9
|
Yamamoto A, Nagao M, Ando K, Nakao R, Matsuo Y, Sakai A, Momose M, Kaneko K, Hagiwara N, Sakai S. First Validation of Myocardial Flow Reserve Derived from Dynamic 99mTc-Sestamibi CZT-SPECT Camera Compared with 13N-Ammonia PET. Int Heart J 2022; 63:202-209. [PMID: 35354742 DOI: 10.1536/ihj.21-487] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
13N-ammonia positron emission tomography (NH3-PET) can evaluate myocardial blood flow (MBF) at rest, stress, and myocardial flow reserve (MFR) as well as the ratio of MBF at stress to that at rest. MFR is useful in predicting the prognoses of patients with various heart diseases. Cadmium-zinc-telluride single photon emission computed tomography (CZT-SPECT) enables us to acquire dynamic images of radiotracer kinetics and measure original MBF and MFR using 99mTc-sestamibi. This study aimed to investigate the utility of CZT-SPECT for quantitative assessment of MBF compared to NH3-PET. We validated the correlation of MBF and MFR between CZT-SPECT and NH3-PET. Fourteen patients using one-day rest/stress CZT-SPECT, D-SPECT followed by NH3-PET within 1 month were enrolled and analyzed prospectively. The reproducibility of the MBF and MFR obtained with these two methods was examined using Spearman's correlation coefficient and Bland-Altman plot analysis. The diagnostic value of D-SPECT for abnormal MFR defined using NH3-PET results as MFR < 2.0 was assessed using receiver-operating characteristic (ROC) analysis. The median duration between D-SPECT and NH3-PET was 20 days. Although MBF was overestimated by D-SPECT compared to NH3-PET at high value (mean difference, 0.43 [0.34-0.53]), MBF and MFR were correlated with the two modalities (MBF: r = 0.71, P < 0.0001, MFR: r = 0.60, P < 0.0001). The ROC curve analysis demonstrated a cutoff of 1.6 for detecting abnormal MFR with D-SPECT (sensitivity, 68%; specificity, 91%; AUC, 0.75). MBF and MFR obtained using D-SPECT and NH3-PET had a good correlation, suggesting that the quantitative MFR evaluation by CZT-SPECT may help understand the trend of NH3-PET MFR.
Collapse
Affiliation(s)
- Atsushi Yamamoto
- Department of Cardiology, Tokyo Women's Medical University.,Department of Imaging Diagnosis and Nuclear Medicine, Tokyo Women's Medical University
| | - Michinobu Nagao
- Department of Imaging Diagnosis and Nuclear Medicine, Tokyo Women's Medical University
| | - Kiyoe Ando
- Department of Cardiology, Tokyo Women's Medical University
| | - Risako Nakao
- Department of Cardiology, Tokyo Women's Medical University
| | - Yuka Matsuo
- Department of Imaging Diagnosis and Nuclear Medicine, Tokyo Women's Medical University
| | - Akiko Sakai
- Department of Cardiology, Tokyo Women's Medical University
| | - Mitsuru Momose
- Department of Imaging Diagnosis and Nuclear Medicine, Tokyo Women's Medical University
| | - Koichiro Kaneko
- Department of Imaging Diagnosis and Nuclear Medicine, Tokyo Women's Medical University
| | | | - Shuji Sakai
- Department of Imaging Diagnosis and Nuclear Medicine, Tokyo Women's Medical University
| |
Collapse
|
10
|
Comeau ZJ, Lessard BH, Shuhendler AJ. The Need to Pair Molecular Monitoring Devices with Molecular Imaging to Personalize Health. Mol Imaging Biol 2022; 24:675-691. [PMID: 35257276 PMCID: PMC8901094 DOI: 10.1007/s11307-022-01714-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 02/16/2022] [Accepted: 02/18/2022] [Indexed: 12/11/2022]
Abstract
By enabling the non-invasive monitoring and quantification of biomolecular processes, molecular imaging has dramatically improved our understanding of disease. In recent years, non-invasive access to the molecular drivers of health versus disease has emboldened the goal of precision health, which draws on concepts borrowed from process monitoring in engineering, wherein hundreds of sensors can be employed to develop a model which can be used to preventatively detect and diagnose problems. In translating this monitoring regime from inanimate machines to human beings, precision health posits that continual and on-the-spot monitoring are the next frontiers in molecular medicine. Early biomarker detection and clinical intervention improves individual outcomes and reduces the societal cost of treating chronic and late-stage diseases. However, in current clinical settings, methods of disease diagnoses and monitoring are typically intermittent, based on imprecise risk factors, or self-administered, making optimization of individual patient outcomes an ongoing challenge. Low-cost molecular monitoring devices capable of on-the-spot biomarker analysis at high frequencies, and even continuously, could alter this paradigm of therapy and disease prevention. When these devices are coupled with molecular imaging, they could work together to enable a complete picture of pathogenesis. To meet this need, an active area of research is the development of sensors capable of point-of-care diagnostic monitoring with an emphasis on clinical utility. However, a myriad of challenges must be met, foremost, an integration of the highly specialized molecular tools developed to understand and monitor the molecular causes of disease with clinically accessible techniques. Functioning on the principle of probe-analyte interactions yielding a transducible signal, probes enabling sensing and imaging significantly overlap in design considerations and targeting moieties, however differing in signal interpretation and readout. Integrating molecular sensors with molecular imaging can provide improved data on the personal biomarkers governing disease progression, furthering our understanding of pathogenesis, and providing a positive feedback loop toward identifying additional biomarkers and therapeutics. Coupling molecular imaging with molecular monitoring devices into the clinical paradigm is a key step toward achieving precision health.
Collapse
Affiliation(s)
- Zachary J Comeau
- Department of Chemical and Biological Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
- Department of Chemistry and Biomolecular Sciences, University of Ottawa, 150 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
| | - Benoît H Lessard
- Department of Chemical and Biological Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
- School of Electrical Engineering and Computer Science, University of Ottawa, 800 King Edward Ave., Ottawa, ON, K1N 6N5, Canada
| | - Adam J Shuhendler
- Department of Chemistry and Biomolecular Sciences, University of Ottawa, 150 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada.
- Department of Biology, University of Ottawa, 30 Marie Curie, Ottawa, ON, K1N 6N5, Canada.
- University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, ON, K1Y 4W7, Canada.
| |
Collapse
|
11
|
Polomski EAS, Antoni ML, Jukema JW, Kroep JR, Dibbets-Schneider P, Sattler MGA, de Geus-Oei LF. Nuclear medicine imaging methods of radiation-induced cardiotoxicity. Semin Nucl Med 2022; 52:597-610. [PMID: 35246310 DOI: 10.1053/j.semnuclmed.2022.02.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 02/06/2022] [Indexed: 12/21/2022]
Abstract
Breast cancer survival is significantly improved over the past decades due to major improvements in anti-tumor therapies and the implementation of regular screening, which leads to early detection of breast cancer. Therefore, it is of utmost importance to prevent patients from long-term side effects, including radiotherapy-induced cardiotoxicity. Radiotherapy may contribute to damage of myocardial structures on the cellular level, which eventually could result in various types of cardiovascular problems, including coronary artery disease and (non-)ischemic cardiomyopathy, leading to heart failure. These cardiac complications of radiotherapy are preceded by alterations in myocardial perfusion and blood flow. Therefore, early detection of these alterations is important to prevent the progression of these pathophysiological processes. Several radionuclide imaging techniques may contribute to the early detection of these changes. Single-Photon Emission Computed Tomography (SPECT) cameras can be used to create Multigated Acquisition scans in order to assess the left ventricular systolic and diastolic function. Furthermore, SPECT cameras are used for myocardial perfusion imaging with radiopharmaceuticals such as 99mTc-sestamibi and 99mTc-tetrofosmin. Accurate quantitative measurement of myocardial blood flow (MBF), can be performed by Positron Emission Tomography (PET), as the uptake of some of the tracers used for PET-based MBF measurement almost creates a linear relationship with MBF, resulting in very accurate blood flow quantification. Furthermore, there are PET and SPECT tracers that can assess inflammation and denervation of the cardiac sympathetic nervous system. Research over the past decades has mainly focused on the long-term development of left ventricular impairment and perfusion defects. Considering laterality of the breast cancer, some early studies have shown that women irradiated for left-sided breast cancer are more prone to cardiotoxic side effects than women irradiated for right-sided breast cancer. The left-sided radiation field in these trials, which predominantly used older radiotherapy techniques without heart-sparing techniques, included a larger volume of the heart and left ventricle, leading to increased unavoidable radiation exposure to the heart due to the close proximity of the radiation treatment volume. Although radiotherapy for breast cancer exposes the heart to incidental radiation, several improvements and technical developments over the last decades resulted in continuous reduction of radiation dose and volume exposure to the heart. In addition, radiotherapy reduces loco-regional tumor recurrences and death from breast cancer and improves survival. Therefore, in the majority of patients, the benefits of radiotherapy outweigh the potential very low risk of cardiovascular adverse events after radiotherapy. This review addresses existing nuclear imaging techniques, which can be used to evaluate (long-term) effects of radiotherapy-induced mechanical cardiac dysfunction and discusses the potential use of more novel nuclear imaging techniques, which are promising in the assessment of early signs of cardiac dysfunction in selected irradiated breast cancer patients.
Collapse
Affiliation(s)
| | - Maria Louisa Antoni
- Department of Cardiology, Heart and Lung Centre, Leiden University Medical Center, Leiden, The Netherlands
| | - Johan Wouter Jukema
- Department of Cardiology, Heart and Lung Centre, Leiden University Medical Center, Leiden, The Netherlands
| | - Judith Rian Kroep
- Department of Medical Oncology, Leiden University Medical Center, Leiden, The Netherlands
| | - Petra Dibbets-Schneider
- Department of Radiology, section Nuclear Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Margriet G A Sattler
- Department of Radiotherapy, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Lioe-Fee de Geus-Oei
- Department of Radiology, section Nuclear Medicine, Leiden University Medical Center, Leiden, The Netherlands; Biomedical Photonic Imaging Group, University of Twente, Enschede, The Netherlands
| |
Collapse
|
12
|
Laipply K, Gerson M. Is faster always better? What is the implication of a shorter time to imaging with tetrofosmin compared to sestamibi? J Nucl Cardiol 2021; 28:2629-2632. [PMID: 32405990 DOI: 10.1007/s12350-020-02143-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 04/09/2020] [Indexed: 11/26/2022]
Affiliation(s)
- Kelly Laipply
- Division of Cardiovascular Health and Disease, University of Cincinnati Medical Center, 234 Goodman Ave., Cincinnati, OH, 45219, USA.
| | - Myron Gerson
- Division of Cardiovascular Health and Disease, University of Cincinnati Medical Center, 234 Goodman Ave., Cincinnati, OH, 45219, USA
| |
Collapse
|
13
|
Cardiac hybrid imaging: novel tracers for novel targets. JOURNAL OF GERIATRIC CARDIOLOGY : JGC 2021; 18:748-758. [PMID: 34659381 PMCID: PMC8501382 DOI: 10.11909/j.issn.1671-5411.2021.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Non-invasive cardiac imaging has explored enormous advances in the last few decades. In particular, hybrid imaging represents the fusion of information from multiple imaging modalities, allowing to provide a more comprehensive dataset compared to traditional imaging techniques in patients with cardiovascular diseases. The complementary anatomical, functional and molecular information provided by hybrid systems are able to simplify the evaluation procedure of various pathologies in a routine clinical setting. The diagnostic capability of hybrid imaging modalities can be further enhanced by introducing novel and specific imaging biomarkers. The aim of this review is to cover the most recent advancements in radiotracers development for SPECT/CT, PET/CT, and PET/MRI for cardiovascular diseases.
Collapse
|
14
|
Wu S, Helal-Neto E, Matos APDS, Jafari A, Kozempel J, Silva YJDA, Serrano-Larrea C, Alves Junior S, Ricci-Junior E, Alexis F, Santos-Oliveira R. Radioactive polymeric nanoparticles for biomedical application. Drug Deliv 2021; 27:1544-1561. [PMID: 33118416 PMCID: PMC7599028 DOI: 10.1080/10717544.2020.1837296] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Nowadays, emerging radiolabeled nanosystems are revolutionizing medicine in terms of diagnostics, treatment, and theranostics. These radionuclides include polymeric nanoparticles (NPs), liposomal carriers, dendrimers, magnetic iron oxide NPs, silica NPs, carbon nanotubes, and inorganic metal-based nanoformulations. Between these nano-platforms, polymeric NPs have gained attention in the biomedical field due to their excellent properties, such as their surface to mass ratio, quantum properties, biodegradability, low toxicity, and ability to absorb and carry other molecules. In addition, NPs are capable of carrying high payloads of radionuclides which can be used for diagnostic, treatment, and theranostics depending on the radioactive material linked. The radiolabeling process of nanoparticles can be performed by direct or indirect labeling process. In both cases, the most appropriate must be selected in order to keep the targeting properties as preserved as possible. In addition, radionuclide therapy has the advantage of delivering a highly concentrated absorbed dose to the targeted tissue while sparing the surrounding healthy tissues. Said another way, radioactive polymeric NPs represent a promising prospect in the treatment and diagnostics of cardiovascular diseases such as cardiac ischemia, infectious diseases such as tuberculosis, and other type of cancer cells or tumors.
Collapse
Affiliation(s)
- Shentian Wu
- Department of Radiotherapy Center, Maoming People's Hospital, Maoming City, China
| | - Edward Helal-Neto
- Nuclear Engineering Institute, Brazilian Nuclear Energy Commission, Rio de Janeiro, Brazil
| | | | - Amir Jafari
- Nuclear Engineering Institute, Brazilian Nuclear Energy Commission, Rio de Janeiro, Brazil.,Department of Medical Nanotechnology in the Faculty of Advanced Technology in Medicine, Iran University of Medical Science, Tehran, Iran
| | - Ján Kozempel
- Faculty of Nuclear Sciences and Physical Engineering (FJFI), Czech Technical University in Prague (ČVUT), Prague, Czech Republic
| | | | | | - Severino Alves Junior
- Department of Fundamental Chemistry, Federal University of Pernambuco, Recife, Brazil
| | - Eduardo Ricci-Junior
- Faculty of Pharmacy, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Frank Alexis
- School of Biological Sciences and Engineering, Yachay Tech University, Urcuquí, Ecuador
| | - Ralph Santos-Oliveira
- Nuclear Engineering Institute, Brazilian Nuclear Energy Commission, Rio de Janeiro, Brazil.,Laboratory of Radiopharmacy and Nanoradiopharmaceuticals, Zona Oeste State University, Rio de Janeiro, Brazil
| |
Collapse
|
15
|
Kawano M, Tsuchiya J, Bae H, Kimura K, Yokoyama K, Takahashi M, Honda M, Tominaga M, Tateishi U. Phase I clinical study of NMB58, a novel positron emission tomography (PET)-myocardial perfusion imaging tracer, conducted to evaluate its safety and pharmacokinetics in Japanese healthy adult males. Ann Nucl Med 2021; 35:580-588. [PMID: 33649886 DOI: 10.1007/s12149-021-01601-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 02/15/2021] [Indexed: 10/22/2022]
Abstract
OBJECTIVES NMB58 is a novel positron emission tomography (PET) tracer containing flurpiridaz as an active ingredient and available as a myocardial perfusion imaging tracer that targets mitochondrial complex 1. A phase I clinical study of NMB58 was conducted to evaluate its safety and pharmacokinetics in healthy volunteers. METHODS Ten healthy Japanese volunteers received bolus injection of NMB58 (111-167 MBq) intravenously and underwent imaging studies at rest on day 1. Of these subjects, 5 (day 2 cohort 1; exercise stress) and 5 (day 2 cohort 2; pharmacological stress) similarly underwent stress imaging studies on day 2. The safety of NMB58 was evaluated through monitoring of signs/symptoms, electrocardiography, vital signs, and laboratory examinations at baseline and several time points during 3 days. Sequential whole-body positron emission tomography-computed tomography (PET/CT) scan data were acquired for up to 5-h post-injection, with venous blood and urine samples collected for up to 8-h post-injection. Based on the results of the biodistribution study, the absorbed radiation dose (Rad) was estimated by the Medical Internal Radiation Dose method. RESULTS On day 1, the kidneys were shown to have the highest Rad, followed by the myocardium. On day 2, the myocardium was shown to have the highest Rad, followed by the kidneys. The mean effective doses (EDs) per unit activity administered were 0.021, 0.017 and 0.021 mSv/MBq for overall subjects (day 1), day 2 cohort 1 and day 2 cohort 2, respectively. The estimated exposure dose of NMB58 was similar to or lower than those of radiotracers currently approved for clinical use, including 18F-Fludeoxyglucose. Biodistribution results indicated that NMB58 distributed to the myocardium exhibited high and sustained retention after administration. The cumulative urinary radioactivity excretion rate was shown to be 6.9, 2.3%, and 8.0% of the injected dose in overall subjects (day 1), day 2 cohort 1 and day 2 cohort 2. There were no drug-related adverse events, and the tracer was well tolerated in all subjects. CONCLUSIONS Based on radiation dosimetry, biodistribution, and safety evaluations, NMB58 was found to be a suitable tracer for clinical use in PET myocardial perfusion imaging during exercise or pharmacological stress.
Collapse
Affiliation(s)
- Mirai Kawano
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| | - Junichi Tsuchiya
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan.
| | - Hyeyeol Bae
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| | - Koichiro Kimura
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| | - Kota Yokoyama
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| | - Marie Takahashi
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| | - Makiko Honda
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| | - Masato Tominaga
- Clinical Development Center, Nihon Medi-Physics Co., Ltd, Tokyo, Japan
| | - Ukihide Tateishi
- Department of Diagnostic Radiology and Nuclear Medicine, Tokyo Medical and Dental University, -5-45 Yushima, Bunkyo-ku, Tokyo, 113 - 8510, Japan
| |
Collapse
|
16
|
MacAskill MG, Stadulyte A, Williams L, Morgan TEF, Sloan NL, Alcaide-Corral CJ, Walton T, Wimberley C, McKenzie CA, Spath N, Mungall W, BouHaidar R, Dweck MR, Gray GA, Newby DE, Lucatelli C, Sutherland A, Pimlott SL, Tavares AAS. Quantification of Macrophage-Driven Inflammation During Myocardial Infarction with 18F-LW223, a Novel TSPO Radiotracer with Binding Independent of the rs6971 Human Polymorphism. J Nucl Med 2021; 62:536-544. [PMID: 32859708 PMCID: PMC8049364 DOI: 10.2967/jnumed.120.243600] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 07/28/2020] [Indexed: 01/09/2023] Open
Abstract
Myocardial infarction (MI) is one of the leading causes of death worldwide, and inflammation is central to tissue response and patient outcomes. The 18-kDa translocator protein (TSPO) has been used in PET as an inflammatory biomarker. The aims of this study were to screen novel, fluorinated, TSPO radiotracers for susceptibility to the rs6971 genetic polymorphism using in vitro competition binding assays in human brain and heart; assess whether the in vivo characteristics of our lead radiotracer, 18F-LW223, are suitable for clinical translation; and validate whether 18F-LW223 can detect macrophage-driven inflammation in a rat MI model. Methods: Fifty-one human brain and 29 human heart tissue samples were screened for the rs6971 polymorphism. Competition binding assays were conducted with 3H-PK11195 and the following ligands: PK11195, PBR28, and our novel compounds (AB5186 and LW223). Naïve rats and mice were used for in vivo PET kinetic studies, radiometabolite studies, and dosimetry experiments. Rats underwent permanent coronary artery ligation and were scanned using PET/CT with an invasive input function at 7 d after MI. For quantification of PET signal in the hypoperfused myocardium, K1 (rate constant for transfer from arterial plasma to tissues) was used as a surrogate marker of perfusion to correct the binding potential for impaired radiotracer transfer from plasma to tissue (BPTC). Results: LW223 binding to TSPO was not susceptible to the rs6971 genetic polymorphism in human brain and heart samples. In rodents, 18F-LW223 displayed a specific uptake consistent with TSPO expression, a slow metabolism in blood (69% of parent at 120 min), a high plasma free fraction of 38.5%, and a suitable dosimetry profile (effective dose of 20.5-24.5 μSv/MBq). 18F-LW223 BPTC was significantly higher in the MI cohort within the infarct territory of the anterior wall relative to the anterior wall of naïve animals (32.7 ± 5.0 vs. 10.0 ± 2.4 cm3/mL/min, P ≤ 0.001). Ex vivo immunofluorescent staining for TSPO and CD68 (macrophage marker) resulted in the same pattern seen with in vivo BPTC analysis. Conclusion:18F-LW223 is not susceptible to the rs6971 genetic polymorphism in in vitro assays, has favorable in vivo characteristics, and is able to accurately map macrophage-driven inflammation after MI.
Collapse
Affiliation(s)
- Mark G MacAskill
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
- Edinburgh Imaging, University of Edinburgh, Edinburgh, United Kingdom
| | - Agne Stadulyte
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
- Edinburgh Imaging, University of Edinburgh, Edinburgh, United Kingdom
| | - Lewis Williams
- School of Chemistry, WestCHEM, University of Glasgow, Glasgow, United Kingdom
| | - Timaeus E F Morgan
- School of Chemistry, WestCHEM, University of Glasgow, Glasgow, United Kingdom
| | - Nikki L Sloan
- School of Chemistry, WestCHEM, University of Glasgow, Glasgow, United Kingdom
| | - Carlos J Alcaide-Corral
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
- Edinburgh Imaging, University of Edinburgh, Edinburgh, United Kingdom
| | - Tashfeen Walton
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
- Edinburgh Imaging, University of Edinburgh, Edinburgh, United Kingdom
| | - Catriona Wimberley
- Edinburgh Imaging, University of Edinburgh, Edinburgh, United Kingdom
- Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, United Kingdom
| | - Chris-Anne McKenzie
- MRC Edinburgh Brain Tissue Bank, University of Edinburgh, Edinburgh, United Kingdom
| | - Nick Spath
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - William Mungall
- Bioresearch and Veterinary Services, University of Edinburgh, Edinburgh, United Kingdom
| | - Ralph BouHaidar
- Forensic Pathology, University of Edinburgh, Edinburgh, United Kingdom
| | - Marc R Dweck
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Gillian A Gray
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - David E Newby
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | | | - Andrew Sutherland
- School of Chemistry, WestCHEM, University of Glasgow, Glasgow, United Kingdom
| | - Sally L Pimlott
- School of Medicine, University of Glasgow, Glasgow, United Kingdom; and
- NHS Greater Glasgow and Clyde, Glasgow, United Kingdom
| | - Adriana A S Tavares
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
- Edinburgh Imaging, University of Edinburgh, Edinburgh, United Kingdom
| |
Collapse
|
17
|
Yamada Y, Nakano S, Gatate Y, Okano N, Muramatsu T, Nishimura S, Kuji I, Fukushima K, Matsunari I. Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. J Nucl Cardiol 2021; 28:187-195. [PMID: 30603890 DOI: 10.1007/s12350-018-01585-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 12/17/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. METHODS Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(99mTc-tetrofosmin (TF) or 123I-BMIPP first) followed by simultaneous 99mTc-TF /123I-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. RESULTS The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for 99mTc-TF: 0.97/ for 123I-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). CONCLUSION The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous 99mTc-TF /123I-BMIPP dual-tracer acquisitions in clinical settings.
Collapse
Affiliation(s)
- Yoshihiro Yamada
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shintaro Nakano
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan.
| | - Youdou Gatate
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Nanami Okano
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| | - Toshihiro Muramatsu
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shigeyuki Nishimura
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Ichiei Kuji
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Kenji Fukushima
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| |
Collapse
|
18
|
Duatti A. Review on 99mTc radiopharmaceuticals with emphasis on new advancements. Nucl Med Biol 2021; 92:202-216. [PMID: 32475681 DOI: 10.1016/j.nucmedbio.2020.05.005] [Citation(s) in RCA: 83] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 05/07/2020] [Accepted: 05/18/2020] [Indexed: 02/06/2023]
Abstract
Rapid imaging acquisition, high spatial resolution and sensitivity, powered by advancements in solid-state detector technology, are significantly changing the perspective of single photon emission tomography (SPECT). In particular, this evolutionary step is fueling a rediscovery of technetium-99m, a still unique radionuclide within the nuclear medicine scenario because of its ideal nuclear properties and easy preparation of its radiopharmaceuticals that does not require a costly infrastructure and complex procedures. Scope of this review is to show that the arsenal of technetium-99m radiopharmaceuticals is already equipped with imaging agents that may complement and integrate the role played by analogous tracers developed for positron emission tomography (PET). These include, in particular, somatostatin (SST) and prostate-specific membrane antigen (PSMA) receptor targeting agents, and a number of peptide-derived radiopharmaceuticals. Additionally, these recent technological developments, combined with new myocardial perfusion tracers having more favorable biodistribution and pharmacokinetic properties as compared to current commercial agents, may also reinvigorate the prevailing position still hold by technetium-99m radiopharmaceuticals in nuclear cardiology.
Collapse
Affiliation(s)
- Adriano Duatti
- Department of Chemical and Pharmaceutical Sciences, University of Ferrara, Ferrara, Italy.
| |
Collapse
|
19
|
D'Amico A, Ugga L, Cocozza S, Giorgio SMDA, Cicala D, Santoro C, Melis D, Cinalli G, Brunetti A, Pappatà S. Multimodal evaluation of the cerebrovascular reserve in Neurofibromatosis type 1 patients with Moyamoya syndrome. Neurol Sci 2020; 42:655-663. [PMID: 32651859 PMCID: PMC7843564 DOI: 10.1007/s10072-020-04574-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 07/02/2020] [Indexed: 11/25/2022]
Abstract
Purpose Moyamoya syndrome (MMS) is a rare intracranial arterial vasculopathy which can occur in neurofibromatosis type 1 (NF1) disease, representing a cause of cerebrovascular reserve (CVR) impairment, possibly leading to ischemic stroke. Here, we evaluated noninvasive imaging techniques used to assess CVR in MMS patients, describing clinical and imaging findings in patients affected by MMS-NF1. Methods Following strict inclusion and exclusion criteria, in this retrospective observational study, we evaluated imaging data of nine consecutive MMS-NF1 patients (M/F = 5/4, mean age: 12.6 ± 4.0). Subjects underwent a multimodal evaluation of cerebral vascular status, including intracranial arterial MR Angiography (MRA), MRI perfusion with dynamic susceptibility contrast (DSC) technique, and 99mTc-hexamethylpropyleneamine oxime (HMPAO) SPECT. Results In 8 out 9 patients (88.8%, 6/8 symptomatic), time-to-peak maps were correlated with the involved cerebral hemisphere, while in 6 out 9 patients (66.6%, 5/6 symptomatic), mean transit time (MTT) maps showed correspondence with the affected cerebrovascular territories. Cerebral blood flow (CBF) calculated using DSC perfusion failed to detect the hypoperfused regions instead identified by SPECT-CBF in all patients, while MTT maps overlapped with SPECT-CBF data in all cases and time-to-peak maps in 60.0%. Conclusions Although SPECT imaging still represents the gold standard for CBF assessment, our results suggest that data obtained using DSC perfusion technique, and in particular MTT maps, might be a very useful and noninvasive tool for evaluating hemodynamic status in MMS-NF1 patients. Electronic supplementary material The online version of this article (10.1007/s10072-020-04574-4) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Alessandra D'Amico
- Department of Advanced Biomedical Sciences, University of Naples "Federico II", Via Pansini, 5, 80131, Naples, Italy
| | - Lorenzo Ugga
- Department of Advanced Biomedical Sciences, University of Naples "Federico II", Via Pansini, 5, 80131, Naples, Italy
| | - Sirio Cocozza
- Department of Advanced Biomedical Sciences, University of Naples "Federico II", Via Pansini, 5, 80131, Naples, Italy.
| | | | - Domenico Cicala
- Department of Pediatric Neurosurgery, Santobono-Pausilipon Children's Hospital, Naples, Italy
| | - Claudia Santoro
- Referral Centre of Neurofibromatosis, Department of Woman and Child, Specialistic and General Surgery, University "Luigi Vanvitelli", Naples, Italy
| | - Daniela Melis
- Department of Translational Medical Sciences, Section of Pediatrics, University of Naples "Federico II", Naples, Italy
| | - Giuseppe Cinalli
- Department of Pediatric Neurosurgery, Santobono-Pausilipon Children's Hospital, Naples, Italy
| | - Arturo Brunetti
- Department of Advanced Biomedical Sciences, University of Naples "Federico II", Via Pansini, 5, 80131, Naples, Italy
| | - Sabina Pappatà
- Institute of Biostructure and Bioimaging, National Research Council, Naples, Italy
| |
Collapse
|
20
|
Ferreira MJV, Cerqueira MD. Clinical Applications of Nuclear Cardiology. Clin Nucl Med 2020. [DOI: 10.1007/978-3-030-39457-8_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
21
|
Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging. Curr Opin Cardiol 2019; 34:473-483. [PMID: 31219878 DOI: 10.1097/hco.0000000000000646] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW The assessment of myocardial viability continues to be a pressing and sometimes challenging clinical question. Among other imaging modalities proven to be useful in the assessment of myocardial viability, single-photon emission computed tomography (SPECT) instrumentation and expertise continue to be the most widely available to the practicing physicians. Understanding the utility of SPECT myocardial perfusion imaging in this domain is an enduring need. RECENT FINDINGS A wealth of basic science and clinical data established the value of a variety of Tl-201 and Tc-99m SPECT protocols in the assessment of myocardial viability. The diagnostic performance for Tl-201 and Tc-99m imaging protocols for identifying viable myocardium is very good and is comparable for both agents. Quantitative assessment of radiotracer uptake can predict, in an objective manner, the probability of recovery of myocardial function following revascularization. SUMMARY SPECT myocardial perfusion imaging with Tl-201 and Tc-99m tracers can provide an objective and quantifiable assessment of myocardial viability, which can help predict the likelihood of myocardial function recovery following coronary revascularization. Effective application of this imaging technique can guide clinical decision-making for coronary revascularization.
Collapse
|
22
|
Robinson AA, Bourque JM. Emerging Techniques for Cardiovascular PET. CARDIOVASCULAR INNOVATIONS AND APPLICATIONS 2019; 4:13-24. [PMID: 34552704 PMCID: PMC8455121 DOI: 10.15212/cvia.2019.0004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The application of positron emission tomography (PET) to cardiac disease has yielded tremendous developments in the evaluation of coronary artery, myocardial, and valvular heart disease over the past several decades. These advances have included development of new radiotracers, incremental technological improvements, and coupling of PET with other non-invasive cardiac imaging modalities. The current era has seen rapid, successive and wide-ranging advances in PET myocardial perfusion and metabolic imaging. This review will address emerging techniques in cardiovascular PET imaging, including the measurement of absolute myocardial blood flow (MBF), use of novel tracers, and other advances in heart failure, infection imaging, and valvular disease.
Collapse
Affiliation(s)
- Austin A. Robinson
- Cardiovascular Division and the Cardiovascular Imaging Center, Department of Medicine, University of Virginia Health System, Charlottesville, VA
| | - Jamieson M. Bourque
- Cardiovascular Division and the Cardiovascular Imaging Center, Department of Medicine, University of Virginia Health System, Charlottesville, VA
- Department of Radiology, University of Virginia Health System, Charlottesville, VA
| |
Collapse
|
23
|
He Y, Zhang X, Liu J, Zhang J, Wang X. Radiosynthesis of β-phenylethylamine derivatives for cardiac sympathetic nervous PET imaging. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-018-06405-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
24
|
Jiang J, Li K, Komarov S, O'Sullivan JA, Tai YC. Feasibility study of a point-of-care positron emission tomography system with interactive imaging capability. Med Phys 2019; 46:1798-1813. [PMID: 30667069 DOI: 10.1002/mp.13397] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Revised: 12/26/2018] [Accepted: 01/14/2019] [Indexed: 12/21/2022] Open
Abstract
PURPOSE We investigated the feasibility of a novel positron emission tomography (PET) system that provides near real-time feedback to an operator who can interactively scan a patient to optimize image quality. The system should be compact and mobile to support point-of-care (POC) molecular imaging applications. In this study, we present the key technologies required and discuss the potential benefits of such new capability. METHODS The core of this novel PET technology includes trackable PET detectors and a fully three-dimensional, fast image reconstruction engine implemented on multiple graphics processing units (GPUs) to support dynamically changing geometry by calculating the system matrix on-the-fly using a tube-of-response approach. With near real-time image reconstruction capability, a POC-PET system may comprise a maneuverable front PET detector and a second detector panel which can be stationary or moved synchronously with the front detector such that both panels face the region-of-interest (ROI) with the detector trajectory contoured around a patient's body. We built a proof-of-concept prototype using two planar detectors each consisting of a photomultiplier tube (PMT) optically coupled to an array of 48 × 48 lutetium-yttrium oxyorthosilicate (LYSO) crystals (1.0 × 1.0 × 10.0 mm3 each). Only 38 × 38 crystals in each arrays can be clearly re-solved and used for coincidence detection. One detector was mounted to a robotic arm which can position it at arbitrary locations, and the other detector was mounted on a rotational stage. A cylindrical phantom (102 mm in diameter, 150 mm long) with nine spherical lesions (8:1 tumor-to-background activity concentration ratio) was imaged from 27 sampling angles. List-mode events were reconstructed to form images without or with time-of-flight (TOF) information. We conducted two Monte Carlo simulations using two POC-PET systems. The first one uses the same phantom and detector setup as our experiment, with the detector coincidence re-solving time (CRT) ranging from 100 to 700 ps full-width-at-half-maximum (FWHM). The second study simulates a body-size phantom (316 × 228 × 160 mm3 ) imaged by a larger POC-PET system that has 4 × 6 modules (32 × 32 LYSO crystals/module, four in axial and six in transaxial directions) in the front panel and 3 × 8 modules (16 × 16 LYSO crystals/module, three in axial and eight in transaxial directions) in the back panel. We also evaluated an interactive scanning strategy by progressively increasing the number of data sets used for image reconstruction. The updated images were analyzed based on the number of data sets and the detector CRT. RESULTS The proof-of-concept prototype re-solves most of the spherical lesions despite a limited number of coincidence events and incomplete sampling. TOF information reduces artifacts in the reconstructed images. Systems with better timing resolution exhibit improved image quality and reduced artifacts. We observed a reconstruction speed of 0.96 × 106 events/s/iteration for 600 × 600 × 224 voxel rectilinear space using four GPUs. A POC-PET system with significantly higher sensitivity can interactively image a body-size object from four angles in less than 7 min. CONCLUSIONS We have developed GPU-based fast image reconstruction capability to support a PET system with arbitrary and dynamically changing geometry. Using TOF PET detectors, we demonstrated the feasibility of a PET system that can provide timely visual feedback to an operator who can scan a patient interactively to support POC imaging applications.
Collapse
Affiliation(s)
- Jianyong Jiang
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MI, 63110, USA
| | - Ke Li
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MI, 63130, USA
| | - Sergey Komarov
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MI, 63110, USA
| | - Joseph A O'Sullivan
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MI, 63130, USA
| | - Yuan-Chuan Tai
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MI, 63110, USA
| |
Collapse
|
25
|
Salvarese N, Carta D, Marzano C, Gerardi G, Melendez-Alafort L, Bolzati C. [99mTc][Tc(N)(DASD)(PNPn)]+ (DASD = 1,4-Dioxa-8-azaspiro[4,5]decandithiocarbamate, PNPn = Bisphosphinoamine) for Myocardial Imaging: Synthesis, Pharmacological and Pharmacokinetic Studies. J Med Chem 2018; 61:11114-11126. [DOI: 10.1021/acs.jmedchem.8b01191] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Nicola Salvarese
- Institute of Condensed Matter Chemistry and Technologies for Energy (ICMATE)-CNR, Corso Stati Uniti, 4, 35127 Padova, Italy
| | - Davide Carta
- Department of Pharmaceutical and Pharmacological Sciences, University of Padua, Via Marzolo, 5, 35131 Padova, Italy
| | - Cristina Marzano
- Department of Pharmaceutical and Pharmacological Sciences, University of Padua, Via Marzolo, 5, 35131 Padova, Italy
| | - Gabriele Gerardi
- Department of Veterinary Clinical Science, University of Padua, Viale dell’Università 16, 35020 Legnaro, Padua, Italy
| | | | - Cristina Bolzati
- Institute of Condensed Matter Chemistry and Technologies for Energy (ICMATE)-CNR, Corso Stati Uniti, 4, 35127 Padova, Italy
| |
Collapse
|
26
|
Mohammadinia S, Abedi SM, Noaparast Z. St. John’s Wort accelerates the liver clearance of technetium-99-sestamibi in rats. Nucl Med Commun 2018; 39:839-844. [DOI: 10.1097/mnm.0000000000000880] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
27
|
Sanad MH, Farag AB, Motaleb MA. Radioiodination and biological evaluation of landiolol as a tracer for myocardial perfusion imaging: preclinical evaluation and diagnostic nuclear imaging. RADIOCHIM ACTA 2018. [DOI: 10.1515/ract-2018-2980] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Abstract
The present work has assessed the ability and competency of radioiodinated landiolol that is considered a potential cardio selective imaging agent. Landiolol was radiosynthesized with [131I] using chloramine-T (Ch-T) as an oxidizing agent. To give high radiochemical yield of the [131I]landiolol reaching values of 98% with high stability up to 48 h. The labeled compound was separated and purified using thin layer chromatography (TLC), paper electrophoresis and high performance liquid chromatography (HPLC). Biodistribution studies indicated that [131I]landiolol gave high heart uptake ratio of [45.0±0.19% ID/g at 2 min post injection (p.i.)]. Therefore, [131I]landiolol could be considered as a novel tracer to image heart with high heart/blood ratio within 60 min.
Collapse
Affiliation(s)
- M. H. Sanad
- Labeled Compounds Department , Hot Labs Center, Atomic Energy Authority , P.O. Box 13759 , Cairo , Egypt , Tel.: 00201006131628, Fax: 0020225180527, E-mail:
| | - A. B. Farag
- Pharmaceutical Chemistry Department, Faculty of Pharmacy , Ahram Canadian University , Giza , Egypt
| | - M. A. Motaleb
- Labeled Compounds Department , Hot Labs Center, Atomic Energy Authority , P.O. Box 13759 , Cairo , Egypt
| |
Collapse
|
28
|
Sakr TM, Ibrahim AB, Fasih TW, Rashed HM. Preparation and biological profile of 99mTc-lidocaine as a cardioselective imaging agent using 99mTc eluted from 99Mo/99mTc generator based on Al–Mo gel. J Radioanal Nucl Chem 2017. [DOI: 10.1007/s10967-017-5560-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
29
|
Li Z, Gupte AA, Zhang A, Hamilton DJ. Pet Imaging and its Application in Cardiovascular Diseases. Methodist Debakey Cardiovasc J 2017; 13:29-33. [PMID: 28413580 DOI: 10.14797/mdcj-13-1-29] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Cardiovascular diseases (CVDs) are the leading cause of death worldwide and represent a great challenge for modern research and medicine. Despite advances in preventing and treating CVD over the decades, there remains an urgent need to develop sensitive and safe methods for early detection and personalized treatment. With refinements of molecular imaging technologies such as positron emission tomography (PET), noninvasive imaging of CVDs is experiencing impressive progress in both preclinical and clinical settings. In this review, we summarize advances in cardiovascular PET imaging, highlight the latest development of CVD imaging probes, and illustrate the potential for individualized therapy based on metabolic phenotype.
Collapse
Affiliation(s)
- Zheng Li
- Houston Methodist Research Institute, Houston Methodist Hospital, Houston, Texas
| | - Anisha A Gupte
- Houston Methodist Research Institute, Houston Methodist Hospital, Houston, Texas
| | - Anjun Zhang
- Houston Methodist Research Institute, Houston Methodist Hospital, Houston, Texas
| | - Dale J Hamilton
- Houston Methodist Research Institute, Houston Methodist Hospital, Houston, Texas
| |
Collapse
|
30
|
Quantification of Myocardial Blood Flow with CZT SPECT Imaging: Is It Ready for Clinical Use? CURRENT CARDIOVASCULAR IMAGING REPORTS 2017. [DOI: 10.1007/s12410-017-9432-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
31
|
Li J, Houle CR, Spalding JR, Yang H, Xiang CQ, Kitt TM, Kristy RM, Wu EQ. Attributes of nuclear imaging centers impacting physician referrals for single-photon emission computed tomography myocardial perfusion imaging tests. J Med Econ 2017; 20:777-785. [PMID: 28406042 DOI: 10.1080/13696998.2017.1314969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
AIM To evaluate nuclear imaging center attributes that cardiologists and primary care physicians (PCPs) consider when referring patients for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) tests, and how these attributes impact physician referral decisions in the United States. METHODS A targeted literature review and seven one-to-one interviews with physicians and imaging center directors were conducted to identify attributes that could impact physicians' referral decisions. The impact of the identified attributes was assessed via an online discrete choice survey among eligible PCPs and cardiologists randomly selected from a nationally representative panel, and quantified with an odds ratio (OR) scale estimated with a multivariable logistic regression. RESULTS Nine two-level attributes were identified: ease of the referral process, waiting time for tests, insurance preauthorization assistance, time to receive results, conclusive test reports, patient satisfaction, a protocol for rapid conversion from an exercise to a pharmacological stress test, patient communication, and assistance with parking/wheelchair access. A total of 410 physicians, including 208 (50.7%) cardiologists and 202 (49.3%) PCPs completed the survey. Among all physicians, a protocol that allows for a rapid conversion from an exercise to a pharmacological stress test (OR = 2.9) and preauthorization assistance (OR = 2.6) were the most impactful attributes. Additionally, cardiologists preferred imaging centers that provide an easy referral process (OR = 2.7), while PCPs favored centers offering a conclusive test report (OR = 2.4). LIMITATIONS Some center features that might impact physician referral decision were not evaluated in this study, if they were not easily changeable from an imaging center's perspective. CONCLUSIONS The availability of a protocol for rapid conversion from an exercise to a pharmacological stress test and preauthorization assistance had the most significant impact on physician referral decisions for SPECT-MPI. Additionally, cardiologists preferred centers providing an easy referral process, while PCPs favored those offering a concluding statement and actionable steps in test reports.
Collapse
Affiliation(s)
- Junlong Li
- a Analysis Group Inc. , Boston , MA , USA
| | - Christy R Houle
- b Astellas Pharma Global Development Inc. , Northbrook , IL , USA
| | - James R Spalding
- b Astellas Pharma Global Development Inc. , Northbrook , IL , USA
| | | | | | - Therese M Kitt
- b Astellas Pharma Global Development Inc. , Northbrook , IL , USA
| | - Rita M Kristy
- b Astellas Pharma Global Development Inc. , Northbrook , IL , USA
| | - Eric Q Wu
- a Analysis Group Inc. , Boston , MA , USA
| |
Collapse
|
32
|
Abstract
The present study aimed to discuss the role of mitochondrion in cardiac function and disease. The mitochondrion plays a fundamental role in cellular processes ranging from metabolism to apoptosis. The mitochondrial-targeted molecular imaging could potentially illustrate changes in global and regional cardiac dysfunction. The collective changes that occur in mitochondrial-targeted molecular imaging probes have been widely explored and developed. As probes currently used in the preclinical setting still have a lot of shortcomings, the development of myocardial metabolic activity, viability, perfusion, and blood flow molecular imaging probes holds great potential for accurately evaluating the myocardial viability and functional reserve. The advantages of molecular imaging provide a perspective on investigating the mitochondrial function of the myocardium in vivo noninvasively and quantitatively. The molecular imaging tracers of single-photon emission computed tomography and positron emission tomography could give more detailed information on myocardial metabolism and restoration. In this study, series mitochondrial-targeted 99mTc-, 123I-, and 18F-labeled tracers displayed broad applications because they could provide a direct link between mitochondrial dysfunction and cardiac disease.
Collapse
|
33
|
Jáni L, Bordi L, Morariu M, Nyulas T, Kovács I, Benedek A, Benedek I. Imaging Techniques for the Assessment of Myocardial Perfusion. JOURNAL OF INTERDISCIPLINARY MEDICINE 2016. [DOI: 10.1515/jim-2016-0069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
One of the most significant causes of heart failure is coronary heart disease and subsequent left ventricular dysfunction. The prognosis and perioperative mortality are influenced by left ventricular function, which is also an important predictor marker following revascularization. The evaluation of myocardial perfusion is of utmost importance in patients who present several symptoms before choosing cardiac catheterization as treatment. The evaluation of myocardial perfusion and myocardial viability leads to superior diagnostic and treatment algorithms, thus resulting in an important improvement in the outcomes of patients with coronary artery disease. Color Doppler myocardial imaging, single-photon emission computed tomography (SPECT), contrast perfusion echocardiography, positron emission computed tomography (PET) and magnetic resonance imaging (MRI) are currently used methods for assessing myocardial perfusion. This review aims to summarize the benefits and disadvantages of each of these techniques.
Collapse
Affiliation(s)
- Laura Jáni
- Center of Advanced Research in Multimodality Cardiac Imaging, Cardio Med Medical Center, Tîrgu Mureș, Romania
| | - Lehel Bordi
- Center of Advanced Research in Multimodality Cardiac Imaging, Cardio Med Medical Center, Tîrgu Mureș, Romania
| | - Mirabela Morariu
- Center of Advanced Research in Multimodality Cardiac Imaging, Cardio Med Medical Center, Tîrgu Mureș, Romania
| | - Tiberiu Nyulas
- University of Medicine and Pharmacy, Tîrgu Mureș, Romania
| | - István Kovács
- University of Medicine and Pharmacy, Tîrgu Mureș, Romania
| | - Annabell Benedek
- Center of Advanced Research in Multimodality Cardiac Imaging, Cardio Med Medical Center, Tîrgu Mureș, Romania
| | - Imre Benedek
- Center of Advanced Research in Multimodality Cardiac Imaging, Cardio Med Medical Center, Tîrgu Mureș, Romania
- University of Medicine and Pharmacy, Tîrgu Mureș, Romania
| |
Collapse
|
34
|
Motaleb MA, Ibrahim IT, Abo Rizq RS, Elzanfaly ES. Preparation, chromatographic evaluation and biodistribution of 99mTc-procainamide as a radiopharmaceutical for heart imaging. RADIOCHIM ACTA 2016. [DOI: 10.1515/ract-2015-2558] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
Procainamide (4-amino-N-[2-(diethylamino) ethyl] benzamide) is a sodium channel blocker, which acts as an effective antiarrhythmic agent used in the treatment of a variety of atrial and ventricular arrhythmias. The aim of this study was to prepare 99mTc-procainamide complex, apply different chromatographic techniques for the assay of radiolabeling yield and study its biodistribution as a novel radiopharmaceutical for heart imaging. 99mTc-procainamide was obtained with a maximum labeling yield of 95.76±0.20% via direct labeling method under optimum conditions of 200 μg of procainamide, 300 μL of buffer (carbonate) at pH 11, 30 μg SnCl2·2H2O at room temperature (25°C) for 15 min. In terms of in vitro stability, the complex was stable for 3 h. Chromatographic evaluation using paper chromatography, thin layer chromatography, gel chromatography, and high performance liquid chromatography showed reliable results for measuring the radiochemical yield. Biodistribution study of 99mTc-procainamide showed ratios of heart/lung and heart/liver (6.38±1.50, 2.06±0.31, respectively at 30 min post injection) which was comparable to that of 99mTc-sestamibi (7.4±2.00, 0.97±0.10, respectively at 60 min, P<0.05).
Collapse
Affiliation(s)
- M. A. Motaleb
- Labeled Compound Department, Hot Laboratory Center, Atomic Energy Authority, P.O. 13759, Cairo, Egypt
| | - I. T. Ibrahim
- Labeled Compound Department, Hot Laboratory Center, Atomic Energy Authority, P.O. 13759, Cairo, Egypt
| | - R. S. Abo Rizq
- Labeled Compound Department, Hot Laboratory Center, Atomic Energy Authority, P.O. 13759, Cairo, Egypt
| | - E. S. Elzanfaly
- Analytical Department, Faculty of Pharmacy, Cairo University, Egypt
| |
Collapse
|
35
|
Olivas Arroyo C. Radiopharmaceuticals in positron emission tomography: present situation and future perspectives. RADIOLOGIA 2016; 58:468-480. [PMID: 27592111 DOI: 10.1016/j.rx.2016.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 05/08/2016] [Accepted: 07/05/2016] [Indexed: 11/29/2022]
Abstract
Positron emission tomography (PET) is an imaging technique that has grown greatly in recent years. PET is considered a fundamental tool in oncology, and it also has indications in other fields such as neurology and cardiology. Although 18F-fluorodeoxyglucose (18F-FDG) is the radiopharmaceutical most widely used in PET, the availability of new radiotracers has been a key element in the expansion of the use of PET. These new radiopharmaceuticals have made it possible to study different biological targets that are essential for obtaining greater knowledge and better characterization of different diseases and have thus contributed to the research and development of different therapeutic agents. This article provides a description of different PET radiopharmaceutical, structured according to their areas of application. Some of these radiotracers are already commercially available, whereas others are still under research or pending approval by regulatory bodies.
Collapse
Affiliation(s)
- C Olivas Arroyo
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Universitari i Politècnic La Fe, Valencia, España.
| |
Collapse
|
36
|
Martinelli J, Denkova AG, Arranja A, Terpstra BE, Zhang W, Djanashvili K. Fate of Organic Functionalities Conjugated to Theranostic Nanoparticles upon Their Activation. Bioconjug Chem 2016; 27:446-56. [PMID: 26619135 DOI: 10.1021/acs.bioconjchem.5b00552] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Neutron activation is widely applied for the preparation of radioactive isotopes to be used in imaging and/or therapy. The type of diagnostic/therapeutic agents varies from small chelates coordinating radioactive metal ions to complex nanoparticulate systems. Design of these agents often relies on conjugation of certain organic functionalities that determine their pharmacokinetics, biodistribution, targeting, and cell-penetrating abilities, or simply on tagging them with an optical label. The conjugation chemistry at the surface of nanoparticles and their final purification often require laborious procedures that become even more troublesome when radioactive materials are involved. This study represents a thorough investigation on the effects of neutron activation on the organic moieties of functionalized nanoparticles, with special focus on (166)Ho2O3 particles conjugated with PEG-fluorescein and PEG-polyarginine motives. Spectroscopic and thermogravimetric analyses demonstrate only a limited degradation of PEG-fluorescein upon irradiation of the particles up to 10 h using a thermal neutron flux of 5 × 10(16) m(-2) s(-1). Cell experiments show that the polyarginine-based mechanisms of membrane penetration remain unaltered after exposure of the functionalized particles to the mixed field of neutrons and gammas present during activation. This confirms that radiation damage on the PEG-polyarginines is minimal. Intrinsic radiations from (166)Ho do not seem to affect the integrity of conjugated organic material. These findings open up a new perspective to simplify the procedures for the preparation of functionalized metal-based nanosystems that need to be activated by neutron irradiation in order to be applied for diagnostic and/or therapeutic purposes.
Collapse
Affiliation(s)
- Jonathan Martinelli
- Department of Biotechnology, Delft University of Technology , Julianalaan 136, 2628 BL Delft, The Netherlands
| | - Antonia G Denkova
- Radiation Science and Technology, Delft University of Technology , Mekelweg 15, 2629 JB Delft, The Netherlands
| | - Alexandra Arranja
- Radiation Science and Technology, Delft University of Technology , Mekelweg 15, 2629 JB Delft, The Netherlands.,Institut Charles Sadron (CNRS) , 23 Rue du Loess, 67034 Strasbourg, France
| | - Baukje E Terpstra
- Radiation Science and Technology, Delft University of Technology , Mekelweg 15, 2629 JB Delft, The Netherlands
| | - Wuyuan Zhang
- Department of Biotechnology, Delft University of Technology , Julianalaan 136, 2628 BL Delft, The Netherlands
| | - Kristina Djanashvili
- Department of Biotechnology, Delft University of Technology , Julianalaan 136, 2628 BL Delft, The Netherlands
| |
Collapse
|
37
|
Tweet MS, Arruda-Olson AM, Anavekar NS, Pellikka PA. Stress echocardiography: what is new and how does it compare with myocardial perfusion imaging and other modalities? Curr Cardiol Rep 2016; 17:43. [PMID: 25911442 DOI: 10.1007/s11886-015-0600-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Cardiovascular disease is a leading cause of morbidity and mortality, and noninvasive strategies to diagnose and risk stratify patients remain paramount in the evaluative process. Stress echocardiography is a well-established, versatile, real-time imaging modality with advantages including lack of radiation exposure, portability, and affordability. Innovative techniques in stress echocardiography include myocardial contrast echocardiography, deformation imaging, three-dimensional (3D) echocardiography, and assessment of coronary flow reserve. Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) or positron emission tomography (PET) are imaging alternatives, and stress cardiac magnetic resonance imaging and coronary computed tomography (CT) angiography, including CT perfusion imaging, are emerging as newer approaches. This review will discuss recent and upcoming developments in the field of stress testing, with an emphasis on stress echocardiography while highlighting comparisons with other modalities.
Collapse
Affiliation(s)
- Marysia S Tweet
- Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, 200 1st Street SW, Rochester, MN, 55905, USA,
| | | | | | | |
Collapse
|
38
|
|
39
|
|
40
|
Xie T, Lee C, Bolch WE, Zaidi H. Assessment of radiation dose in nuclear cardiovascular imaging using realistic computational models. Med Phys 2015; 42:2955-66. [PMID: 26127049 PMCID: PMC5148206 DOI: 10.1118/1.4921364] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Revised: 04/24/2015] [Accepted: 05/08/2015] [Indexed: 12/26/2022] Open
Abstract
PURPOSE Nuclear cardiology plays an important role in clinical assessment and has enormous impact on the management of a variety of cardiovascular diseases. Pediatric patients at different age groups are exposed to a spectrum of radiation dose levels and associated cancer risks different from those of adults in diagnostic nuclear medicine procedures. Therefore, comprehensive radiation dosimetry evaluations for commonly used myocardial perfusion imaging (MPI) and viability radiotracers in target population (children and adults) at different age groups are highly desired. METHODS Using Monte Carlo calculations and biological effects of ionizing radiation VII model, we calculate the S-values for a number of radionuclides (Tl-201, Tc-99m, I-123, C-11, N-13, O-15, F-18, and Rb-82) and estimate the absorbed dose and effective dose for 12 MPI radiotracers in computational models including the newborn, 1-, 5-, 10-, 15-yr-old, and adult male and female computational phantoms. RESULTS For most organs, (201)Tl produces the highest absorbed dose whereas (82)Rb and (15)O-water produce the lowest absorbed dose. For the newborn baby and adult patient, the effective dose of (82)Rb is 48% and 77% lower than that of (99m)Tc-tetrofosmin (rest), respectively. CONCLUSIONS (82)Rb results in lower effective dose in adults compared to (99m)Tc-labeled tracers. However, this advantage is less apparent in children. The produced dosimetric databases for various radiotracers used in cardiovascular imaging, using new generation of computational models, can be used for risk-benefit assessment of a spectrum of patient population in clinical nuclear cardiology practice.
Collapse
Affiliation(s)
- Tianwu Xie
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211, Switzerland
| | - Choonsik Lee
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health, Bethesda, Maryland 20852
| | - Wesley E Bolch
- Departments of Nuclear & Radiological and Biomedical Engineering, University of Florida, Gainesville, Florida 32611
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211, Switzerland; Geneva Neuroscience Center, Geneva University, Geneva CH-1205, Switzerland; and Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB, Netherlands
| |
Collapse
|
41
|
Alexanderson-Rosas E, Guinto-Nishimura GY, Cruz-Mendoza JR, Oropeza-Aguilar M, De La Fuente-Mancera JC, Barrero-Mier AF, Monroy-Gonzalez A, Juarez-Orozco LE, Cano-Zarate R, Meave-Gonzalez A. Current and future trends in multimodality imaging of coronary artery disease. Expert Rev Cardiovasc Ther 2015; 13:715-31. [PMID: 25912725 DOI: 10.1586/14779072.2015.1039991] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Nowadays, there is a wide array of imaging studies available for the evaluation of coronary artery disease, each with its particular indications and strengths. Cardiac single photon emission tomography is mostly used to evaluate myocardial perfusion, having experienced recent marked improvements in image acquisition. Cardiac PET has its main utility in perfusion imaging, atherosclerosis and endothelial function evaluation, and viability assessment. Cardiovascular computed tomography has long been used as a reference test for non-invasive evaluation of coronary lesions and anatomic characterization. Cardiovascular magnetic resonance is currently the reference standard for non-invasive ventricular function evaluation and myocardial scarring delineation. These specific strengths have been enhanced with the advent of hybrid equipment, offering a true integration of different imaging modalities into a single, simultaneous and comprehensive study.
Collapse
Affiliation(s)
- Erick Alexanderson-Rosas
- Department of Nuclear Cardiology, Instituto Nacional de Cardiología 'Ignacio Chávez', Mexico City, Mexico
| | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Li Y, Zhang W, Wu H, Liu G. Advanced tracers in PET imaging of cardiovascular disease. BIOMED RESEARCH INTERNATIONAL 2014; 2014:504532. [PMID: 25389529 PMCID: PMC4214169 DOI: 10.1155/2014/504532] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Revised: 07/07/2014] [Accepted: 08/08/2014] [Indexed: 02/04/2023]
Abstract
Cardiovascular disease is the leading cause of death worldwide. Molecular imaging with targeted tracers by positron emission tomography (PET) allows for the noninvasive detection and characterization of biological changes at the molecular level, leading to earlier disease detection, objective monitoring of therapies, and better prognostication of cardiovascular diseases progression. Here we review, the current role of PET in cardiovascular disease, with emphasize on tracers developed for PET imaging of cardiovascular diseases.
Collapse
Affiliation(s)
- Yesen Li
- Department of Nuclear Medicine, The First Affiliated Hospital of Xiamen University, Xiamen 361003, China
- Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
| | - Wei Zhang
- Department of Orthopedics, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu 610072, China
- Sichuan Key Laboratory of Medical Imaging, North Sichuan Medical College, Nanchong 637007, China
| | - Hua Wu
- Department of Nuclear Medicine, The First Affiliated Hospital of Xiamen University, Xiamen 361003, China
| | - Gang Liu
- Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, China
| |
Collapse
|
43
|
Molecular imaging of plaques in coronary arteries with PET and SPECT. JOURNAL OF GERIATRIC CARDIOLOGY : JGC 2014; 11:259-73. [PMID: 25278976 PMCID: PMC4178519 DOI: 10.11909/j.issn.1671-5411.2014.03.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 08/15/2014] [Accepted: 08/19/2014] [Indexed: 01/26/2023]
Abstract
Coronary artery disease remains a major cause of mortality. Presence of atherosclerotic plaques in the coronary artery is responsible for lumen stenosis which is often used as an indicator for determining the severity of coronary artery disease. However, the degree of coronary lumen stenosis is not often related to compromising myocardial blood flow, as most of the cardiac events that are caused by atherosclerotic plaques are the result of vulnerable plaques which are prone to rupture. Thus, identification of vulnerable plaques in coronary arteries has become increasingly important to assist identify patients with high cardiovascular risks. Molecular imaging with use of positron emission tomography (PET) and single photon emission computed tomography (SPECT) has fulfilled this goal by providing functional information about plaque activity which enables accurate assessment of plaque stability. This review article provides an overview of diagnostic applications of molecular imaging techniques in the detection of plaques in coronary arteries with PET and SPECT. New radiopharmaceuticals used in the molecular imaging of coronary plaques and diagnostic applications of integrated PET/CT and PET/MRI in coronary plaques are also discussed.
Collapse
|