1
|
Macías-Naranjo M, Sánchez-Domínguez M, Rubio-Valle JF, Rodríguez CA, Martín-Alfonso JE, García-López E, Vazquez-Lepe E. A Study of PLA Thin Film on SS 316L Coronary Stents Using a Dip Coating Technique. Polymers (Basel) 2024; 16:284. [PMID: 38276692 PMCID: PMC10818791 DOI: 10.3390/polym16020284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/04/2024] [Accepted: 01/05/2024] [Indexed: 01/27/2024] Open
Abstract
The dip coating process is one of the recognized techniques used to generate polymeric coatings on stents in an easy and low-cost way. However, there is a lack of information about the influence of the process parameters of this technique on complex geometries such as stents. This paper studies the dip coating process parameters used to provide a uniform coating of PLA with a 4-10 µm thickness. A stainless-steel tube (AISI 316L) was laser-cut, electropolished, and dip-coated in a polylactic acid (PLA) solution whilst changing the process parameters. The samples were characterized to examine the coating's uniformity, thickness, surface roughness, weight, and chemical composition. FTIR and Raman investigations indicated the presence of PLA on the stent's surface, the chemical stability of PLA during the coating process, and the absence of residual chloroform in the coatings. Additionally, the water contact angle was measured to determine the hydrophilicity of the coating. Our results indicate that, when using entry and withdrawal speeds of 500 mm min-1 and a 15 s immersion time, a uniform coating thickness was achieved throughout the tube and in the stent with an average thickness of 7.8 µm.
Collapse
Affiliation(s)
- Mariana Macías-Naranjo
- Tecnologico de Monterrey, School of Engineering and Sciences, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Nuevo León, Mexico; (M.M.-N.); (C.A.R.)
| | - Margarita Sánchez-Domínguez
- Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Unidad Monterrey, Alianza Norte 202, Apodaca 66628, Nuevo León, Mexico;
| | - J. F. Rubio-Valle
- Pro2TecS—Chemical Product and Process Technology Research Center, Department of Chemical Engineering and Materials Science, ETSI, Universidad de Huelva, Campus de “El Carmen”, 21071 Huelva, Spain; (J.F.R.-V.); (J.E.M.-A.)
| | - Ciro A. Rodríguez
- Tecnologico de Monterrey, School of Engineering and Sciences, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Nuevo León, Mexico; (M.M.-N.); (C.A.R.)
| | - J. E. Martín-Alfonso
- Pro2TecS—Chemical Product and Process Technology Research Center, Department of Chemical Engineering and Materials Science, ETSI, Universidad de Huelva, Campus de “El Carmen”, 21071 Huelva, Spain; (J.F.R.-V.); (J.E.M.-A.)
| | - Erika García-López
- Tecnologico de Monterrey, School of Engineering and Sciences, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Nuevo León, Mexico; (M.M.-N.); (C.A.R.)
| | - Elisa Vazquez-Lepe
- Tecnologico de Monterrey, School of Engineering and Sciences, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Nuevo León, Mexico; (M.M.-N.); (C.A.R.)
| |
Collapse
|
2
|
Bi S, Lin H, Zhu K, Zhu Z, Zhang W, Yang X, Chen S, Zhao J, Liu M, Pan P, Liang G. Chitosan-salvianolic acid B coating on the surface of nickel-titanium alloy inhibits proliferation of smooth muscle cells and promote endothelialization. Front Bioeng Biotechnol 2023; 11:1300336. [PMID: 38026871 PMCID: PMC10679528 DOI: 10.3389/fbioe.2023.1300336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 11/01/2023] [Indexed: 12/01/2023] Open
Abstract
Introduction: Intracranial stents are of paramount importance in managing cerebrovascular disorders. Nevertheless, the currently employed drug-eluting stents, although effective in decreasing in-stent restenosis, might impede the re-endothelialization process within blood vessels, potentially leading to prolonged thrombosis development and restenosis over time. Methods: This study aims to construct a multifunctional bioactive coating to enhance the biocompatibility of the stents. Salvianolic acid B (SALB), a bioactive compound extracted from Salvia miltiorrhiza, exhibits potential for improving cardiovascular health. We utilized dopamine as the base and adhered chitosan-coated SALB microspheres onto nickel-titanium alloy flat plates, resulting in a multifunctional drug coating. Results: By encapsulating SALB within chitosan, the release period of SALB was effectively prolonged, as evidenced by the in vitro drug release curve showing sustained release over 28 days. The interaction between the drug coating and blood was examined through experiments on water contact angle, clotting time, and protein adsorption. Cellular experiments showed that the drug coating stimulates the proliferation, adhesion, and migration of human umbilical vein endothelial cells. Discussion: These findings indicate its potential to promote re-endothelialization. In addition, the bioactive coating effectively suppressed smooth muscle cells proliferation, adhesion, and migration, potentially reducing the occurrence of neointimal hyperplasia and restenosis. These findings emphasize the exceptional biocompatibility of the newly developed bioactive coating and demonstrate its potential clinical application as an innovative strategy to improve stent therapy efficacy. Thus, this coating holds great promise for the treatment of cerebrovascular disease.
Collapse
Affiliation(s)
- Shijun Bi
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
- Graduate School, Dalian Medical University, Dalian, China
| | - Hao Lin
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Kunyuan Zhu
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
- Graduate School, China Medical University, Shenyang, China
| | - Zechao Zhu
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
| | - Wenxu Zhang
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
| | - Xinyu Yang
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
| | - Shanshan Chen
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Jing Zhao
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Meixia Liu
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Pengyu Pan
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
| | - Guobiao Liang
- Department of Neurosurgery, General Hospital of Northern Theater Command, Shenyang, China
| |
Collapse
|
3
|
Patel S, Patel KB, Patel Z, Konat A, Patel A, Doshi JS, Chokshi P, Patel D, Sharma K, Amdani MM, Shah DB, Dholu U, Patel M. Evolving Coronary Stent Technologies - A Glimpse Into the Future. Cureus 2023; 15:e35651. [PMID: 37009355 PMCID: PMC10065169 DOI: 10.7759/cureus.35651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/27/2023] [Indexed: 03/06/2023] Open
Abstract
One of the most widely accepted forms of treatment for coronary artery disease (CAD) is the implementation of stents into the vessel. This area of research is constantly evolving, ranging from bare-metal stents through drug-eluting stents and, more recently, approaching bioresorbable stents and polymer-free stents. This article reviews the evolution of all these devices and emphasizes how they might be further evolved to provide an optimal coronary stent and overcome unsolved challenges in stent development. We thoroughly evaluated a number of published studies in order to advance coronary stent technologies. Additionally, we looked for various literature that highlighted the inadequacies of the coronary stents that are currently available and how they might be modified to create the optimum coronary stent. Coronary stents have significantly improved clinical outcomes in interventional cardiology, but there are still a number of drawbacks, including an persisted risk of thrombosis due to endothelial injury and in-stent restenosis. Gene eluting stents (GES) and customized coronary stents with self-reporting stent sensors are appealing alternatives to existing stent approaches. Considering the adequacy of these gene eluting stents (GES), customized coronary stents produced by novel 4D printing technologies and integrated self-reporting stent sensors should be assumed for anticipating future advancements to optimal coronary stent devices; however, more interventional evidence is required to determine the future prospects of these stent innovations.
Collapse
|
4
|
Yi Y, Wang B, Li C. Sensors-based monitoring and treatment approaches for in-stent restenosis. J Biomed Mater Res B Appl Biomater 2023; 111:490-498. [PMID: 36161478 DOI: 10.1002/jbm.b.35164] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 08/11/2022] [Accepted: 09/11/2022] [Indexed: 12/15/2022]
Abstract
Cardiovascular disease (CVD) can progressively narrow arteries due to plaque accumulation on the inner walls of the blood vessels, which results in an obstructed blood flow, leading to heart attack, stroke, and even death if the obstruction is severe. A popular treatment for the disease is to use an intravascular mechanical device called the stent to achieve an immediate restoration of blood flow. However, the physical stimulation induced by the stent expansion can cause inflammation of the vessel tissue. As one of the most common post-stenting complications, re-narrowing of the vessel is the main pathology that leads to in-stent restenosis (ISR), induced by the excess growth of the tissue over the deployed stent. The ISR is widely recognized as a significant cause of death globally if early symptoms are not detected. Hence, monitoring and early diagnosis indeed matter when it comes to treatment. The latest technologies for monitoring and treatments of ISR were reviewed in this work, and the potential issues and suggestions related to the reported technologies were presented. The target of this review aims to positively prompt researchers to develop an advanced stent system in terms of its electromechanical performance, size, functional feature, feasibility, and reliability.
Collapse
Affiliation(s)
- Ying Yi
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan, China
| | - Bo Wang
- College of Science and Engineering, Hamad Bin Khalifa University, Doha, Qatar
| | - Changping Li
- College of Communication and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China
| |
Collapse
|
5
|
Additive Manufacturing of Polymer/Mg-Based Composites for Porous Tissue Scaffolds. Polymers (Basel) 2022; 14:polym14245460. [PMID: 36559829 PMCID: PMC9783552 DOI: 10.3390/polym14245460] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 11/29/2022] [Accepted: 12/07/2022] [Indexed: 12/23/2022] Open
Abstract
Due to their commercial availability, superior processability, and biocompatibility, polymers are frequently used to build three-dimensional (3D) porous scaffolds. The main issues limiting the widespread clinical use of monophasic polymer scaffolds in the bone healing process are their inadequate mechanical strength and inappropriate biodegradation. Due to their mechanical strength and biocompatibility, metal-based scaffolds have been used for various bone regenerative applications. However, due to the mismatch in mechanical properties and nondegradability, they lack integration with the host tissues, resulting in the production of fiber tissue and the release of toxic ions, posing a risk to the durability of scaffolds. Due to their natural degradability in the body, Mg and its alloys increasingly attract attention for orthopedic and cardiovascular applications. Incorporating Mg micro-nano-scale particles into biodegradable polymers dramatically improves scaffolds and implants' strength, biocompatibility, and biodegradability. Polymer biodegradable implants also improve the quality of life, particularly for an aging society, by eliminating the secondary surgery often needed to remove permanent implants and significantly reducing healthcare costs. This paper reviews the suitability of various biodegradable polymer/Mg composites for bone tissue scaffolds and then summarizes the current status and challenges of polymer/magnesium composite scaffolds. In addition, this paper reviews the potential use of 3D printing, which has a unique design capability for developing complex structures with fewer material waste at a faster rate, and with a personalized and on-site fabrication possibility.
Collapse
|
6
|
Baek SW, Kim DS, Song DH, Lee S, Lee JK, Park SY, Kim JH, Kim TH, Park CG, Han DK. PLLA Composites Combined with Delivery System of Bioactive Agents for Anti-Inflammation and Re-Endothelialization. Pharmaceutics 2022; 14:pharmaceutics14122661. [PMID: 36559156 PMCID: PMC9782680 DOI: 10.3390/pharmaceutics14122661] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/24/2022] [Accepted: 11/25/2022] [Indexed: 12/02/2022] Open
Abstract
The development of a biodegradable vascular scaffold (BVS) for the treatment of cardiovascular diseases (CVDs) still requires some improvement. Among them, re-endothelialization and anti-inflammation are clinically important to restore vascular function. In this study, we proposed a coating system to deliver hydrophilic bioactive agents to BVS using nanoemulsion and drop-casting methods. The poly(L-lactide) (PLLA) scaffold containing magnesium hydroxide (MH) was coated on the surface with bioactive molecules such as polydeoxyribonucleotide (PDRN), L-arginine (Arg, R), and mesenchymal stem cell-derived extracellular vesicles (EVs). PDRN upregulates the expression of VEGF as one of the A2A receptor agonists; and Arg, synthesized into nitric oxide by intracellular eNOS, induces endothelialization. In particular, EVs, which are composed of a lipid bilayer and transfer bioactive materials such as protein and nucleic acid, regulate homeostasis in blood vessels. Such a bioactive agent coating system and its PLLA composite suggest a new platform for the treatment of cardiovascular dysfunction.
Collapse
Affiliation(s)
- Seung-Woon Baek
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
- Department of Biomedical Engineering, SKKU Institute for Convergence, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon-si 16419, Republic of Korea
- Department of Intelligent Precision Healthcare Convergence, SKKU Institute for Convergence, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon-si 16419, Republic of Korea
| | - Da-Seul Kim
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
- School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Republic of Korea
| | - Duck Hyun Song
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
| | - Semi Lee
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
| | - Jun-Kyu Lee
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
| | - So-Yeon Park
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
- Division of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Seoul 02841, Republic of Korea
| | - Jun Hyuk Kim
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
| | - Tae-Hyung Kim
- School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Republic of Korea
| | - Chun Gwon Park
- Department of Biomedical Engineering, SKKU Institute for Convergence, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon-si 16419, Republic of Korea
- Department of Intelligent Precision Healthcare Convergence, SKKU Institute for Convergence, Sungkyunkwan University (SKKU), 2066 Seobu-ro, Jangan-gu, Suwon-si 16419, Republic of Korea
| | - Dong Keun Han
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si 13488, Republic of Korea
- Correspondence:
| |
Collapse
|
7
|
Hassan S, Najabat Ali M, Ghafoor B. An appraisal of polymers of DES technology and their impact on drug release kinetics. INT J POLYM MATER PO 2022. [DOI: 10.1080/00914037.2022.2090941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Sadia Hassan
- Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Murtaza Najabat Ali
- Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Bakhtawar Ghafoor
- Department of Biomedical Engineering and Sciences, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| |
Collapse
|
8
|
Magnesium-Based Alloys Used in Orthopedic Surgery. MATERIALS 2022; 15:ma15031148. [PMID: 35161092 PMCID: PMC8840615 DOI: 10.3390/ma15031148] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 01/27/2022] [Accepted: 01/29/2022] [Indexed: 02/04/2023]
Abstract
Magnesium (Mg)-based alloys have become an important category of materials that is attracting more and more attention due to their high potential use as orthopedic temporary implants. These alloys are a viable alternative to nondegradable metals implants in orthopedics. In this paper, a detailed overview covering alloy development and manufacturing techniques is described. Further, important attributes for Mg-based alloys involved in orthopedic implants fabrication, physiological and toxicological effects of each alloying element, mechanical properties, osteogenesis, and angiogenesis of Mg are presented. A section detailing the main biocompatible Mg-based alloys, with examples of mechanical properties, degradation behavior, and cytotoxicity tests related to in vitro experiments, is also provided. Special attention is given to animal testing, and the clinical translation is also reviewed, focusing on the main clinical cases that were conducted under human use approval.
Collapse
|
9
|
Molloy A, Beaumont K, Alyami A, Kirimi M, Hoare D, Mirzai N, Heidari H, Mitra S, Neale SL, Mercer JR. Challenges to the development of the next generation of self-reporting cardiovascular implantable medical devices. IEEE Rev Biomed Eng 2021; 15:260-272. [PMID: 34520361 DOI: 10.1109/rbme.2021.3110084] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Cardiovascular disease (CVD) is a group of heart and vasculature conditions which are the leading form of mortality worldwide. Blood vessels can become narrowed, restricting blood flow, and drive the majority of hearts attacks and strokes. Surgical interventions are frequently required; including percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG). Despite successful opening of vessels and restoration of blood flow, often in-stent restenosis (ISR) and graft failure can still occur, resulting in subsequent patient morbidity and mortality. A new generation of cardiovascular implants that have sensors and real-time monitoring capabilities are being developed to combat ISR and graft failure. Self-reporting stent/graft technology could enable precision medicine-based healthcare by detecting the earliest features of disease, even before symptoms occur. Bringing an implantable medical device with wireless electronic sensing capabilities to market is complex and often obstructive undertaking. This critical review analyses the obstacles that need to be overcome for self-reporting stents/grafts to be developed and provide a precision-medicine based healthcare for cardiovascular patients. Here we assess the latest research and technological advancement in the field, the current devices and the market potential for their end-user implementation.
Collapse
|
10
|
Chioncel V, Andrei CL, Brezeanu R, Sinescu C, Avram A, Tatu AL. Some Perspectives on Hypersensitivity to Coronary Stents. Int J Gen Med 2021; 14:4327-4336. [PMID: 34408475 PMCID: PMC8364397 DOI: 10.2147/ijgm.s326679] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Accepted: 07/22/2021] [Indexed: 11/23/2022] Open
Abstract
The development of coronary stents has represented a revolution in the treatment of coronary heart disease. Beyond their many advantages, stents also have their limitations and complications. Allergic reactions to coronary stents are more common than acknowledged. These stented patients are exposed to foreign substances inserted in direct contact with the coronary intima. Hypersensitivity to stent components and drugs prescribed after stent insertion together with any environmental exposure seem to contribute to these adverse reactions. Patients can present to the hospital with a wide range of symptoms and multiple complications, the most important ones being instent restenosis and stent thrombosis. Although not very common (and not always easy to identify), allergic reactions after coronary or peripheral stents should be taken into account. Careful selection of patients (for elective stent implantation) depending on the propensity to allergies, although hard to achieve, represents a key factor in reducing the number of these complications.
Collapse
Affiliation(s)
- Valentin Chioncel
- Department of Cardio-Thoracic Pathology, Faculty of Medicine, "Carol Davila" University of Medicine and Pharmacy, Bucharest, 050474, Romania
| | - Catalina Liliana Andrei
- Department of Cardio-Thoracic Pathology, Faculty of Medicine, "Carol Davila" University of Medicine and Pharmacy, Bucharest, 050474, Romania
| | - Radu Brezeanu
- Department of Cardio-Thoracic Pathology, Faculty of Medicine, "Carol Davila" University of Medicine and Pharmacy, Bucharest, 050474, Romania
| | - Crina Sinescu
- Department of Cardio-Thoracic Pathology, Faculty of Medicine, "Carol Davila" University of Medicine and Pharmacy, Bucharest, 050474, Romania
| | - Anamaria Avram
- Department of Cardio-Thoracic Pathology, Faculty of Medicine, "Carol Davila" University of Medicine and Pharmacy, Bucharest, 050474, Romania
| | - Alin Laurentiu Tatu
- Medical and Pharmaceutical Research Unit/Competitive, Interdisciplinary Research Integrated Platform "Dunărea de Jos", ReForm-UDJG, Research Centre in the Field of Medical and Pharmaceutical Sciences, Faculty of Medicine and Pharmacy, Clinical Medical Department, "Dunărea de Jos" University of Galati, Galati, 800010, Romania
| |
Collapse
|
11
|
Antonini L, Berti F, Isella B, Hossain D, Mandelli L, Pennati G, Petrini L. From the real device to the digital twin: A coupled experimental-numerical strategy to investigate a novel bioresorbable vascular scaffold. PLoS One 2021; 16:e0252788. [PMID: 34086820 PMCID: PMC8177663 DOI: 10.1371/journal.pone.0252788] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 05/21/2021] [Indexed: 11/26/2022] Open
Abstract
The purpose of this work is to propose a workflow that couples experimental and computational activities aimed at developing a credible digital twin of a commercial coronary bioresorbable vascular scaffold when direct access to data about material mechanical properties is not possible. Such a situation is be faced when the manufacturer is not involved in the study, thus directly investigating the actual device is the only source of information available. The object of the work is the Fantom® Encore polymeric stent (REVA Medical) made of Tyrocore™. Four devices were purchased and used in mechanical tests that are easily reproducible in any mechanical laboratory, i.e. free expansion and uniaxial tension testing, the latter performed with protocols that emphasized the rate-dependent properties of the polymer. Given the complexity of the mechanical behaviour observed experimentally, it was chosen to use the Parallel Rehological Framework material model, already used in the literature to describe the behaviour of other polymers, such as PLLA. Calibration of the material model was based on simulations that replicate the tensile test performed on the device. Given the high number of material parameters, a plan of simulations was done to find the most suitable set, varying each parameter value in a feasible range and considering a single repetitive unit of the stent, neglecting residual stresses generated by crimping and expansion. This strategy resulted in a significant reduction of computational cost. The performance of the set of parameters thus identified was finally evaluated considering the whole delivery system, by comparing the experimental results with the data collected simulating free expansion and uniaxial tension testing. Moreover, radial force testing was numerically performed and compared with literature data. The obtained results demonstrated the effectiveness of the digital twin development pipeline, a path applicable to any commercial device whose geometric structure is based on repetitive units.
Collapse
Affiliation(s)
- Luca Antonini
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Francesca Berti
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Benedetta Isella
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Dipok Hossain
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Lorenzo Mandelli
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Giancarlo Pennati
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Lorenza Petrini
- Department of Civil and Environmental Engineering, Politecnico di Milano, Milano, Italy
- * E-mail:
| |
Collapse
|
12
|
Azova M, Timizheva K, Ait Aissa A, Blagonravov M, Gigani O, Aghajanyan A, Tskhovrebova L. Gene Polymorphisms of the Renin-Angiotensin-Aldosterone System as Risk Factors for the Development of In-Stent Restenosis in Patients with Stable Coronary Artery Disease. Biomolecules 2021; 11:biom11050763. [PMID: 34065198 PMCID: PMC8161197 DOI: 10.3390/biom11050763] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/03/2021] [Accepted: 05/17/2021] [Indexed: 11/16/2022] Open
Abstract
This study investigated the renin-angiotensin-aldosterone system (RAAS) gene polymorphisms as possible genetic risk factors for the restenosis development in patients with drug-eluting stents. 113 participants had coronary artery disease and underwent stenting. The control group consisted of 62 individuals with intact coronary arteries. Patients were divided into two groups: with in-stent restenosis (ISR) and without it. The patients with ISR were classified into subgroups by the terms of the restenosis development and age. Real-time PCR and Restriction Fragment Length Polymorphism-PCR were used to genotype the study participants for RAAS gene polymorphisms. We found that the development of restenosis is generally associated with the minor A allele for renin (REN) rs2368564 and the major TT genotype for angiotensinogen (AGT) rs699. The heterozygous genotype for AGT rs4762 acts as a protective marker. A minor A allele for angiotensin II type 2 receptor (AGTR2) rs1403543 is associated with a risk of restenosis in people under 65 years old. Among patients with the early ISR, heterozygotes for angiotensin II type 1 receptor (AGTR1) rs5186 are more frequent, as well as A allele carriers for AGTR2 rs1403543. A minor homozygous genotype for REN rs41317140 and heterozygous genotype for aldosterone synthase (CYP11B2) rs1799998 are predisposed to the late restenosis. Thus, to choose the effective treatment tactics for patients with coronary artery disease, it is necessary to genotype patients for the RAAS polymorphisms, which, along with age and clinical characteristics, will allow a comprehensive assessment of the risk of the restenosis development after stenting.
Collapse
Affiliation(s)
- Madina Azova
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
- Correspondence: ; Tel.: +7-(495)-4345288
| | - Kalima Timizheva
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
- National Medical Research Center of Cardiology of the Ministry of Healthcare of the Russian Federation, 15a 3rd Cherepkovskaya St, 121552 Moscow, Russia
| | - Amira Ait Aissa
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
| | - Mikhail Blagonravov
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
| | - Olga Gigani
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
| | - Anna Aghajanyan
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
| | - Leyla Tskhovrebova
- Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, 117198 Moscow, Russia; (K.T.); (A.A.A.); (M.B.); (O.G.); (A.A.); (L.T.)
- Federal Research and Clinical Center of Physical-Chemical Medicine of Federal Medical Biological Agency, 1a Malaya Pirogovskaya St, 119435 Moscow, Russia
| |
Collapse
|
13
|
Osama S, Wirth F, Zahra G, Barbara C, Xuereb RG, Camilleri L, Azzopardi LM. CYP2C19*2 genetic polymorphism and incidence of in-stent restenosis in patients on clopidogrel: a matched case-control study. Drug Metab Pers Ther 2021; 37:155-161. [PMID: 34851561 DOI: 10.1515/dmpt-2021-0160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 10/01/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The cytochrome P450 2C19*2 (CYP2C19*2) genetic polymorphism is associated with reduced clopidogrel bioactivation, increasing the risk of atherothrombotic complications after percutaneous coronary intervention (PCI). In-stent restenosis (ISR) is a complication that limits the long-term prognosis of PCI. The aim was to investigate the association between presence of the CYP2C19*2 allele and ISR within one-year after PCI in patients prescribed dual antiplatelet therapy with aspirin and clopidogrel. METHODS Sixty patients with angiographically-confirmed drug eluting stent (DES)-ISR within 12 months post-PCI when on DAPT with aspirin and clopidogrel were retrospectively identified (Cases). Another 60 patients with no documented ISR post-PCI in the study period (Controls) were case-matched for age, gender, ethnicity, diabetes mellitus and estimated glomerular filtration rate value, and were invited for CYP2C19*2 genotyping. The association between presence of the CYP2C19*2 allele and ISR was analysed using the Fisher's Exact test and binary logistic regression. RESULTS Twenty-six (43.3%) cases and 5 (8.3%) controls were carriers of one or two CYP2C19*2 alleles. As to non-carrier status of the CYP2C19*2 allele, 34 (56.7%) cases and 55 (91.7%) controls were identified. The association between CYP2C19*2 carrier status and DES-ISR within one-year post-PCI was statistically significant (p<0.001) in both the univariate and multivariate analysis. CONCLUSIONS The proportion of patients who were carriers of one or two CYP2C19*2 alleles who presented with DES-ISR within one-year post-PCI while on clopidogrel was significantly higher compared to patients with no documented ISR.
Collapse
Affiliation(s)
- Sara Osama
- Department of Pharmacy, Faculty of Medicine and Surgery, University of Malta, Msida, Malta
| | - Francesca Wirth
- Department of Pharmacy, Faculty of Medicine and Surgery, University of Malta, Msida, Malta
| | - Graziella Zahra
- Department of Pathology, Molecular Diagnostics Unit, Mater Dei Hospital, Msida, Malta
| | - Christopher Barbara
- Department of Pathology, Molecular Diagnostics Unit, Mater Dei Hospital, Msida, Malta
| | | | - Liberato Camilleri
- Department of Statistics and Operations Research, Faculty of Science, University of Malta, Msida, Malta
| | - Lilian M Azzopardi
- Department of Pharmacy, Faculty of Medicine and Surgery, University of Malta, Msida, Malta
| |
Collapse
|
14
|
The birth, decline, and contemporary re-emergence of endovascular brachytherapy for prevention of in-stent restenosis. Brachytherapy 2020; 20:485-493. [PMID: 33132069 DOI: 10.1016/j.brachy.2020.09.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 09/13/2020] [Accepted: 09/18/2020] [Indexed: 01/08/2023]
Abstract
Despite the advent of drug-eluting stents and dual antiplatelet therapy in the interventional management of cardiovascular disease, restenosis rates remain high with significant sequelae. Endovascular brachytherapy-popular in the 1990s and early 2000s-has recently resurfaced as a cost-effective treatment option. In this work, we outline the history of endovascular brachytherapy starting with its earliest promise in the 1990s. We discuss the development of drug-eluting stents and dual antiplatelet strategies and their impact on the perceived benefit of endovascular brachytherapy. For the contemporary era, we propose novel roles for endovascular brachytherapy in complex coronary artery disease and in high-risk patients managed with drug-eluting stents. We discuss the impetus for reducing the requirement and duration of dual antiplatelet therapy using endovascular brachytherapy. We also review innovative opportunities for endovascular brachytherapy after bare-metal stent placement in both coronary and noncoronary territories and offer economic arguments in favor of endovascular brachytherapy. Trials of endovascular brachytherapy in these regimes are merited.
Collapse
|
15
|
The Impact of Coexistence of Smoking and Diabetes on the Coronary Artery Severity and Outcomes following Percutaneous Coronary Intervention: Results from the 1 ST Jordanian PCI Registry. Int J Vasc Med 2020; 2020:7624158. [PMID: 32695516 PMCID: PMC7352136 DOI: 10.1155/2020/7624158] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/09/2020] [Accepted: 06/17/2020] [Indexed: 12/18/2022] Open
Abstract
Introduction Diabetes mellitus (DM) and smoking are highly prevalent among Middle Eastern patients admitted with acute coronary syndrome (ACS) or who undergo percutaneous coronary intervention (PCI). Methods This study used the analysis of the data from the first Jordanian PCI registry (JoPCR1) to determine the impact of coexistence of smoking and diabetes mellitus on the coronary artery severity and outcome following percutaneous coronary intervention in Middle Eastern patients. Results Of 2426 patients enrolled, 1300 (53.6%) and 1055 (43.5%) were diabetics and smokers, respectively. The patients' age was 59.0 ± 10.1 and ranged between 24 and 95 years. Males comprised 79.4% of all patients. The patients were divided into four groups: nondiabetic-nonsmokers (22.2%), diabetic-nonsmokers (34.3%), nondiabetic-smokers (24.2%), and diabetic-smokers (19.2%). Compared with the other three groups, patients in the diabetic-nonsmoker group were older, more likely to be females, and having a higher prevalence of hypertension, dyslipidemia, chronic renal disease, and history of CVD and revascularization. Consequently, the diabetic-nonsmoker patients (but not the diabetic-smokers) had a higher prevalence of multivessel CAD and PCI than the other three groups, highlighting the importance of other risk factors (age, gender, metabolic syndrome, and comorbidities) and not only smoking in predisposing for CAD. Furthermore, those patients had a higher incidence of ACS as an indication for PCI than the stable coronary disease (73% vs 27%) and the highest CRUSADE bleeding risk score (63.9%) among other groups. The in-hospital events including in-stent thrombosis and emergency CABG events did not significantly differ among groups (p = 0.5 and 0.22). Heart failure and major bleeding events occurred significantly higher among diabetic-nonsmokers compared to other groups. In-hospital deaths occurred significantly more among diabetic-nonsmokers. Moreover, the one-month and one-year follow-up outcome events (the mortality rate, in-stent thrombosis, readmission for ACS, coronary revascularization, and major bleedings) occurred more frequently in the diabetic-nonsmoker group. However, the difference was statistically significant only for major bleeding incidences. Conclusions In this analysis of a completed prospective Middle Eastern PCI registry, the majority of the diabetic-nonsmoker (and not the diabetic-smokers) patients (73%) presented with ACS. This group was the highest at risk for in-hospital PCI complications as well as the worst in outcomes after one year of follow-up. Those patients were more likely to be older, female, and have the worst cardiovascular baseline features, highlighting the importance of other risk factors (age, gender, metabolic syndrome, and comorbidities) and not only smoking in predisposing for CAD. Thus, more sufficient education about controlling CVD risk factors should be implemented in the Middle Eastern region.
Collapse
|
16
|
Lukman SK, Saidin S. Effects of different polyaniline emeraldine compositions in electrodepositing ginsenoside encapsulated poly(lactic-co-glycolic acid) microcapsules coating: Physicochemical characterization and in vitro evaluation. J Biomed Mater Res A 2020; 108:1171-1185. [PMID: 31994824 DOI: 10.1002/jbm.a.36891] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 01/19/2020] [Accepted: 01/21/2020] [Indexed: 01/01/2023]
Abstract
Even though drug-eluting stent (DES) has prominently reduced restenosis, however, its complication of delayed endothelialization has caused chronic side effect. A coating of ginseng-based biodegradable polymer could address this issue due to its specific therapeutic values. However, deposition of this type of stable coating on metallic implant often scarce. Therefore, in this study, different polyaniline (PANI) emeraldine compositions were adopted to electrodeposit ginsenoside encapsulated poly(lactic-co-glycolic acid) microcapsules coating. The coating surfaces were analyzed using attenuated total reflectance-Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, contact angle, and atomic force microscopy instruments. A month coating stability was then investigated with an evaluation of in vitro human umbilical vein endothelial cell analyses consisted of cytotoxicity and cells attachment assessments. The 1.5 mg PANI emeraldine has assisted the formation of stable, uniform, and rounded microcapsules coating with appropriate wettability and roughness. Less than 1.5 mg PANI emeraldine was not enough to drive the formation of microcapsules coating while greater than 1.5 mg caused the deposition of melted microcapsules. The similar coating also has promoted greater cells proliferation and attachment compared to other coating variation. Therefore, the utilization of electrodeposition to deposit a drug-based polymer coating could be implemented to develop DES, in accordance to stent implantation which ultimately aims for enrich endothelialization.
Collapse
Affiliation(s)
- Siti Khadijah Lukman
- School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia
| | - Syafiqah Saidin
- School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia.,IJN-UTM Cardiovascular Engineering Centre, Institute of Human Centered Engineering, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia
| |
Collapse
|
17
|
Tang L, Cui QW, Liu DP, Fu YY. The number of stents was an independent risk of stent restenosis in patients undergoing percutaneous coronary intervention. Medicine (Baltimore) 2019; 98:e18312. [PMID: 31852115 PMCID: PMC6922542 DOI: 10.1097/md.0000000000018312] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Percutaneous coronary intervention (PCI) is one of the most effective therapies for coronary artery disease, but stent restenosis remains an important clinical challenge. The studies about the independent effect of the number of stents on stent restenosis were limited.The purpose was to identify the independent effect of the number of stents on stent restenosis.A retrospective cohort study of data reuse.From July 2009 to August 2011, a total of 2338 cases met the inclusion and exclusion criteria.The univariate analysis showed that the number of stents was a risk of stent restenosis, the OR value was 1.30 (95% CI:1.15 to 1.47, P < .001). The multi-factor regression analysis also showed that the number of stents was an independent risk of stent restenosis, the adjusted OR value was 1.38 (95% CI: 1.15 to 1.66, P < .001).Compared with 1-2 stents, the adjusted OR values of 3-5 stents and more than 6 stents were respectively 2.20 (95% CI: 1.24 to 3.90, P = .007) and 5.33 (95% CI: 1.89 to 15.08, P = .002), and the trend adjusted OR values was 2.26 (95% CI: 1.43 to 3.59, P < .001).The subgroup analysis of multi-factor regression analysis showed that when patients with the following conditions: 50 < Age, female, non-DES or SES, the risk of stent restenosis increased obviously.The number of stents was an independent risk of stent restenosis in patients undergoing PCI, especially for patients with the following conditions: 2<the number of stents, 50 < age, female, Non-DES (Drug-eluting stents) or SES (sirolimus-eluting stent).
Collapse
Affiliation(s)
| | - Qian-Wei Cui
- Department of Cardiovascular, Shaanxi Provincial People's Hospital, Xi’an, Shaanxi, China
| | | | | |
Collapse
|
18
|
Hoare D, Bussooa A, Neale S, Mirzai N, Mercer J. The Future of Cardiovascular Stents: Bioresorbable and Integrated Biosensor Technology. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2019; 6:1900856. [PMID: 31637160 PMCID: PMC6794628 DOI: 10.1002/advs.201900856] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 07/26/2019] [Indexed: 05/15/2023]
Abstract
Cardiovascular disease is the greatest cause of death worldwide. Atherosclerosis is the underlying pathology responsible for two thirds of these deaths. It is the age-dependent process of "furring of the arteries." In many scenarios the disease is caused by poor diet, high blood pressure, and genetic risk factors, and is exacerbated by obesity, diabetes, and sedentary lifestyle. Current pharmacological anti-atherosclerotic modalities still fail to control the disease and improvements in clinical interventions are urgently required. Blocked atherosclerotic arteries are routinely treated in hospitals with an expandable metal stent. However, stented vessels are often silently re-blocked by developing "in-stent restenosis," a wound response, in which the vessel's lumen renarrows by excess proliferation of vascular smooth muscle cells, termed hyperplasia. Herein, the current stent technology and the future of biosensing devices to overcome in-stent restenosis are reviewed. Second, with advances in nanofabrication, new sensing methods and how researchers are investigating ways to integrate biosensors within stents are highlighted. The future of implantable medical devices in the context of the emerging "Internet of Things" and how this will significantly influence future biosensor technology for future generations are also discussed.
Collapse
Affiliation(s)
- Daniel Hoare
- BHF Cardiovascular Research CentreUniversity of GlasgowG12 8TAGlasgowScotland
| | - Anubhav Bussooa
- BHF Cardiovascular Research CentreUniversity of GlasgowG12 8TAGlasgowScotland
| | - Steven Neale
- James Watt South BuildingSchool of EngineeringUniversity of GlasgowG12 8QQGlasgowScotland
| | - Nosrat Mirzai
- Bioelectronics UnitCollege of Medical, Veterinary & Life Sciences (MVLS)University of GlasgowG12 8QQGlasgowScotland
| | - John Mercer
- BHF Cardiovascular Research CentreUniversity of GlasgowG12 8TAGlasgowScotland
| |
Collapse
|
19
|
Binns C, Yun Low W. How Should We Approach Cardiovascular Disease in Asia: Public Health Perspectives? Asia Pac J Public Health 2019; 31:481-484. [DOI: 10.1177/1010539519872565] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Colin Binns
- School of Public Health, Curtin University, Perth, Western Australia, Australia
| | - Wah Yun Low
- Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
20
|
Motovska Z. Trombosis del stent tras la ICP por SCA: ¿la adherencia al tratamiento antiagregante implica más que su intensidad? Rev Esp Cardiol 2019. [DOI: 10.1016/j.recesp.2018.10.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
21
|
Motovska Z. Stent Thrombosis After ACS-PCI: Does Adherence to Antiplatelet Therapy Involve More Than Its Intensity? ACTA ACUST UNITED AC 2018; 72:282-284. [PMID: 30497947 DOI: 10.1016/j.rec.2018.10.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 10/17/2018] [Indexed: 10/27/2022]
Affiliation(s)
- Zuzana Motovska
- Cardiocentre, Third Faculty of Medicine, Charles University, Prague, Czech Republic.
| |
Collapse
|
22
|
Lee SJ, Khang G, Lee YM, Lee HB. The effect of surface wettability on induction and growth of neurites from the PC-12 cell on a polymer surface. J Colloid Interface Sci 2003; 259:228-35. [PMID: 16256501 DOI: 10.1016/s0021-9797(02)00163-7] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2002] [Accepted: 11/20/2002] [Indexed: 10/27/2022]
Abstract
Surface properties of polymeric devices that are used to regenerate nervous damage are a point to be considered for axon regeneration in nerve system. In our previous studies, we prepared a wettability gradient on polyethylene (PE) surfaces using a corona discharge treatment from a knife-type electrode whose power increases gradually along the sample length. The PE surfaces were oxidized gradually with increasing power. The effect of surface wettability on the different types of cells has an important role for cell adhesion and proliferation. The purpose of this study is to investigate neurite formation on polymer surfaces with different wettability. Induction and growth of neurites from the rat pheochromocytoma (PC-12) cells attached on the polymer surfaces with different hydrophilicity were investigated using the wettability gradient PE surfaces prepared by a corona discharge treatment. Neurites were investigated for number and length of neurites in terms of surface wettability. It was observed that neurite formation of PC-12 cells was increased more onto the positions with moderate hydrophilicity of the wettability gradient surface than onto the more hydrophobic or hydrophilic positions. From those results, it could be assumed that initial adhesion of PC-12 cells was caused by more calf serum (CS) protein than nerve growth factor (NGF), whereas the neurite formation of PC-12 cells was caused by more NGF than CS protein. It follows from what has been said thus far that PC-12 cells are a differentiated neuronal phenotype with a long neurite at around the position 2.5 cm (water contact angle of about 55 deg). In conclusion, surface wettability plays an important role for neurite formation on the polymer surfaces for axon regeneration.
Collapse
Affiliation(s)
- Sang Jin Lee
- School of Chemical Engineering, Hanyang University, 17 Haengdang Dong, Seongdong Ku, Seoul 133-791, South Korea
| | | | | | | |
Collapse
|