Bruna J, Prochazkova J, Podzimek S, Himmlova L, Janatova T, Vinsu A. Metal Hypersensitivity in Patients With Failure of Joint Prosthesis Treatment. J Immunol Res 2025; 2025:4319686. [PMID: 40225948 PMCID: PMC11991841 DOI: 10.1155/jimr/4319686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 01/20/2025] [Accepted: 01/29/2025] [Indexed: 04/15/2025] Open
Abstract
The objective of this study is to measure lymphocyte responses to metal antigens using MELISA (memory lymphocyte immunostimulation assay) test-modified lymphocyte transformation test (mLTT) and to evaluate metal sensitization in patients with and without the need of prosthetic surgery. This study is a case-control retrospective survey. We retrospectively analyzed all patients from 2013 to 2018 who were referred to the Institute of Dental Medicine, General University Hospital in Prague, and First Faculty of Medicine, Charles University, Prague, either following joint prosthesis-related complications or as a preoperative evaluation concerning metal hypersensitivity. For the control group, we selected healthy adults from our database. A group of 127 patients aged 25-81 years was chosen, 92 of which were female and 35 were male. The patients completed a special questionnaire aimed at information regarding their health status and history of metal exposure. After clinical examination, their peripheral blood samples were taken to perform mLTT. mLTT provided quantitative lymphocyte proliferation measurement, where a stimulation index of >2 indicated metal sensitivity. For statistical analysis, the Fisher's exact test, χ2 test, McNemar's exact test Student's paired t-test were used. By comparison of the study group and control group mLTT results, it can be stated that patients of the study group showed a higher level of lymphocyte reactivity to most of the tested metal antigens (Ag [silver], Cu [copper], Fe [iron], Mo [molybdenum], Pd [palladium], Pt [platinum], Ti [titanium], and Zn [zinc]) and an elevated incidence of metal hypersensitivity to Hg (mercury), Al (aluminum), Au (gold), Co (cobalt), Cr (chromium), Ni (nickel), and Sn (tin). The evaluation of the data obtained from patients in this study confirmed a significant clinical benefit of mLTT in diagnostics of metal hypersensitivity. Our study has revealed that the patients with the need of prosthetic surgery exhibited an elevated lymphocyte response to metal antigens. This result supports a metal-specific adaptive immune response and suggests involvement of metal exposure as a trigger for their health problems. This knowledge could be helpful in effectively enhancing the treatment of patients with need of orthopedic joint prosthesis.
Collapse
Affiliation(s)
- Jana Bruna
- Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic
| | - Jarmila Prochazkova
- Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic
- Jessenius Faculty of Medicine, Comenius University, Martin, Slovakia
| | - Stepan Podzimek
- Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic
| | - Lucie Himmlova
- Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic
| | - Tatjana Janatova
- Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic
| | - Alex Vinsu
- Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic
| |
Collapse
|
2
|
Gołasz P, Płoska A, Korniienko V, Diedkova K, Varava Y, Zieliński R, Pogorielov M, Simka W. Modification of Ti13Nb13Zr Alloy Surface via Plasma Electrolytic Oxidation and Silver Nanoparticles Decorating. MATERIALS (BASEL, SWITZERLAND) 2025; 18:349. [PMID: 39859817 PMCID: PMC11767042 DOI: 10.3390/ma18020349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2024] [Revised: 01/09/2025] [Accepted: 01/10/2025] [Indexed: 01/27/2025]
Abstract
The dynamically developing field of implantology requires researchers to search for new materials and solutions. In this study, TiNbZr samples were investigated as an alternative for popular, but potentially hazardous TiAl6V4. Samples were etched, sandblasted, subjected to PEO, and covered in AgNP suspension. Simultaneously, SEM images were taken, and the wettability and roughness of the surface were measured. Samples covered in AgNPs were subjected to biological trials. A six-day measurement of human fibroblast proliferation was conducted to assess biocompatibility, and the population of E. coli and S. aureus was measured over eight hours. Results showed that the TiNbZr PEO surface is biocompatible with human fibroblast cells and promotes growth. However, deposited AgNPs exhibited only slight effectiveness in decreasing bacterial growth over the first two hours. The results suggest that the method of surface preparation is sufficient and might promote osseointegration. On the other hand, more efficient and reliable methods of application of AgNPs should be researched.
Collapse
Affiliation(s)
- Przemysław Gołasz
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (P.G.); (A.P.); (M.P.)
- Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| | - Agnieszka Płoska
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (P.G.); (A.P.); (M.P.)
| | - Viktoriia Korniienko
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas iela 3, LV-1004 Riga, Latvia; (V.K.); (K.D.)
- Biomedical Research Centre, Sumy State University, R-Korsakova Street, 40007 Sumy, Ukraine;
| | - Kateryna Diedkova
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas iela 3, LV-1004 Riga, Latvia; (V.K.); (K.D.)
- Biomedical Research Centre, Sumy State University, R-Korsakova Street, 40007 Sumy, Ukraine;
| | - Yuliia Varava
- Biomedical Research Centre, Sumy State University, R-Korsakova Street, 40007 Sumy, Ukraine;
| | | | - Maksym Pogorielov
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (P.G.); (A.P.); (M.P.)
| | - Wojciech Simka
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (P.G.); (A.P.); (M.P.)
| |
Collapse
|
3
|
Kołkowska A, Michalska J, Zieliński R, Simka W. Electrochemical Polishing of Ti and Ti 6Al 4V Alloy in Non-Aqueous Solution of Sulfuric Acid. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2832. [PMID: 38930203 PMCID: PMC11205115 DOI: 10.3390/ma17122832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024]
Abstract
This paper reports the results of our study on electrochemical polishing of titanium and a Ti-based alloy using non-aqueous electrolyte. It was shown that electropolishing ensured the removal of surface defects, thereby providing surface smoothing and decreasing surface roughness. The research was conducted using samples made of titanium and Ti6Al4V alloy, as well as implant system elements: implant analog, multiunit, and healing screw. Electropolishing was carried out under a constant voltage (10-15 V) with a specified current density. The electrolyte used contained methanol and sulfuric acid. The modified surface was subjected to a thorough analysis regarding its surface morphology, chemical composition, and physicochemical properties. Scanning electron microscope images and profilometer tests of roughness confirmed significantly smoother surfaces after electropolishing. The surface profile analysis of processed samples also yielded satisfactory results, showing less imperfections than before modification. The EDX spectra showed that electropolishing does not have significant influence on the chemical composition of the samples.
Collapse
Affiliation(s)
- Agata Kołkowska
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (A.K.); (J.M.)
- Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| | - Joanna Michalska
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (A.K.); (J.M.)
| | - Rafał Zieliński
- Stomatologia na Ksiezym Mlynie, 16D Tymienieckiego, 90-365 Lodz, Poland;
| | - Wojciech Simka
- Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland; (A.K.); (J.M.)
| |
Collapse
|
4
|
Chen A, Kurmis AP. Understanding immune-mediated cobalt/chromium allergy to orthopaedic implants: a meta-synthetic review. ARTHROPLASTY 2024; 6:1. [PMID: 38303027 PMCID: PMC10835847 DOI: 10.1186/s42836-023-00227-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 12/12/2023] [Indexed: 02/03/2024] Open
Abstract
BACKGROUND The frequency of primary joint replacement surgery continues to increase worldwide. While largely considered biologically inert entities, an increasing body of evidence continues to validate a not insignificant incidence of allergic reactions to such implants. Little previous work has explored genuinely immune-mediated reactivity in this context. In the absence of a contemporary published summary on the topic, this paper explored the current state of understanding of cobalt/chromium allergy and proposes a patient management algorithm whereby such immune reactions are clinically suggested. METHODS A structured, systematic literature review was performed by following PRISMA search principles to provide an updated review of this area. RESULTS Thirty-six topic-related articles were identified, the majority reflecting lower tiers of scientific evidence with a lack of homogeneous quantitative data to facilitate valid cohort comparisons. Largely, the available literature represented small case series' or expert opinions. CONCLUSIONS Despite increasing clinical awareness and acknowledgement of true allergy to joint replacement components, this review highlighted that the evidence base underpinning the diagnosis and management of such patients is limited. Both patient-reported metal allergy or skin patch testing are grossly unreliable methods and show almost no correlation with true immune reactivity. Recent studies suggested a potential role for patient-specific in vitro cellular activation testing and/or targeted genetic testing when cobalt/chromium allergy is clinically suspected. However, while likely representing the contemporary "best available" approaches both can be costly undertakings, are not yet universally available, and still require broader validation in non-research settings before wider uptake can be championed.
Collapse
Affiliation(s)
- Arnold Chen
- School of Medicine, University of Adelaide, Adelaide, SA, 5000, Australia
| | - Andrew P Kurmis
- Discipline of Medical Specialties, University of Adelaide, Adelaide, SA, 5000, Australia.
- Department of Orthopaedic Surgery, Lyell McEwin Hospital, Elizabeth Vale, SA, 5112, Australia.
- College of Medicine & Public Health, Flinders University, Bedford Park, SA, 5042, Australia.
| |
Collapse
|
5
|
Luenam S, Kosiyatrakul A, Charoenlap C, Puncreobutr C, Lohwongwatana B. Radial head replacement with the 3D-printed patient-specific titanium prosthesis: Preliminary results of a multi-centric prospective study. J Orthop Surg (Hong Kong) 2024; 32:10225536241236806. [PMID: 38430070 DOI: 10.1177/10225536241236806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/03/2024] Open
Abstract
PURPOSE To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures. MATERIAL AND METHODS This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated. RESULTS The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation. CONCLUSION The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.
Collapse
Affiliation(s)
- Suriya Luenam
- Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand
| | - Arkaphat Kosiyatrakul
- Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand
| | - Chris Charoenlap
- Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Chedtha Puncreobutr
- Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| | - Boonrat Lohwongwatana
- Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
6
|
Tille E, Beyer F, Lützner C, Postler A, Thomas P, Summer B, Lützner J. No difference in patient reported outcome and inflammatory response after coated and uncoated total knee arthroplasty - a randomized controlled study. BMC Musculoskelet Disord 2023; 24:968. [PMID: 38098024 PMCID: PMC10720193 DOI: 10.1186/s12891-023-07061-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 11/24/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Allergies against implant materials are still not fully understood. Despite controversies about its relevance, some patients need treatment with hypoallergenic implants. This study compared coated and standard total knee arthroplasty (TKA) regarding inflammatory response and patient-reported outcome measures (PROMs). METHODS 76 patients without self-reported allergies against implant materials were included in a RCT and received a coated or standard TKA of the same cemented posterior-stabilized knee system. 73 patients completed the 3-year follow-up. Two patients died and there was one revision surgery. Serum levels of cytokines with a possible role in implant allergy were measured in patient`s serum (IL-1beta, IL-5, IL-6, IL-8, IL-10, IFN γ, TNF α) prior to, one and three years after surgery. Furthermore, PROMs including knee function (Oxford Knee Score, Knee Society Score) and health-related quality of life (QoL, EuroQuol questionnaire) were assessed. Additionally, 8 patients with patch-test proven skin allergy against implant materials who received the coated implant were assessed similarly and compared to a matched-pair group receiving the same implant. RESULTS There were no differences in function and QoL between the assessed groups at any follow-up. The majority of patients demonstrated no elevation of the measured blood cytokines. Cytokine patterns showed no differences between study groups at any follow-up. The allergy patients demonstrated slower functional improvement and minor differences in cytokine pattern. Yet these results were not significant. There were no differences in the matched-pair analysis. CONCLUSION We observed no relevant increase in serum cytokine levels in any group. The inflammatory response measured seems limited, even in allergy patients. Furthermore, there were no differences between coated and standard TKA in non-allergy patients in the 3-year Follow-Up period. TRIAL REGISTRATION The study protocol was registered in the US National Institutes of Health's database ( http://www. CLINICALTRIALS gov ) registry under NCT03424174 on 03/17/2016.
Collapse
Affiliation(s)
- Eric Tille
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany.
| | - Franziska Beyer
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| | - Cornelia Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| | - Anne Postler
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| | - Peter Thomas
- Department of Dermatology und Allergology, Ludwig-Maximilians-University, Munich, Germany
| | - Burkhard Summer
- Department of Dermatology und Allergology, Ludwig-Maximilians-University, Munich, Germany
| | - Jörg Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| |
Collapse
|
7
|
Arevalo S, Arthurs C, Molina MIE, Pruitt L, Roy A. An overview of the tribological and mechanical properties of PEEK and CFR-PEEK for use in total joint replacements. J Mech Behav Biomed Mater 2023; 145:105974. [PMID: 37429179 DOI: 10.1016/j.jmbbm.2023.105974] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 06/08/2023] [Accepted: 06/09/2023] [Indexed: 07/12/2023]
Abstract
Poly-ether-ether-ketone (PEEK) and PEEK composites are outstanding candidates for biomedical applications, such as orthopedic devices, where biocompatibility and modulus match with surrounding tissue are requisite for long-term success. The mechanical properties can be optimized by incorporating fillers such as continuous and chopped carbon fibers. While much is known about the mechanical and tribological behavior of PEEK composites, there are few articles that summarize the viability of using PEEK reinforced with carbon fibers in orthopedic implants. This paper reviews biocompatibility, tribological, and mechanical studies on PEEK and their composites with carbon fibers, notably PEEK reinforced with polyacrylonitrile (PAN)-based carbon fibers and PEEK reinforced with pitch-based carbon fibers, for application in orthopedics and total joint replacements (TJRs). The main objectives of this review are two-fold. Firstly, this paper aims to assist designers in making informed decisions on the suitability of using PEEK and PEEK composites in orthopedic applications; as it is not well understood how these materials perform on the whole in orthopedics and TJRs. Secondly, this paper aims to serve as a centralized paper in which researchers can gain information on the tribological and mechanical advancements of PEEK and PEEK composites.
Collapse
Affiliation(s)
- Sofia Arevalo
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Claire Arthurs
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | | | - Lisa Pruitt
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Anurag Roy
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA.
| |
Collapse
|
8
|
Migliorini F, Pilone M, Bell A, Merfort R, Giorgino R, Maffulli N. Serum cobalt and chromium concentration following total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2023; 13:6918. [PMID: 37106086 PMCID: PMC10140036 DOI: 10.1038/s41598-023-34177-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/25/2023] [Indexed: 04/29/2023] Open
Abstract
The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany.
| | - Marco Pilone
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany
| | - Ricarda Merfort
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Riccardo Giorgino
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- School of Pharmacy and Bioengineering, Faculty of Medicine, Keele University, ST4 7QB, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Queen Mary University of London, Mile End Hospital, E1 4DG, London, England
| |
Collapse
|
9
|
Pautasso A, Zorzolo I, Bellato E, Pellegrino P, Ferrario A, Pira E, Castoldi F. Allergic reaction and metal hypersensitivity after shoulder joint replacement. Musculoskelet Surg 2023; 107:55-68. [PMID: 34719773 PMCID: PMC10020248 DOI: 10.1007/s12306-021-00729-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 09/17/2021] [Indexed: 06/13/2023]
Abstract
PURPOSE Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. METHODS Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. RESULTS At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. CONCLUSIONS Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. LEVELS OF EVIDENCE Level II.
Collapse
Affiliation(s)
- A. Pautasso
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - I. Zorzolo
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - E. Bellato
- Orthopaedic and Traumatology Department, San Luigi Gonzaga Hospital, University of Turin, Regione Gonzole 10, 10043 Orbassano, Italy
| | - P. Pellegrino
- Oncologic Orthopaedic Department, Orthopaedic and Trauma Center – Città della Salute e della Scienza, University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - A. Ferrario
- Occupational Medicine Division, Department of Public Health and Pediatric Sciences, Orthopaedic and Trauma Center – Città della Salute e della Scienza, University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - E. Pira
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
- Occupational Medicine Division, Department of Public Health and Pediatric Sciences, Orthopaedic and Trauma Center – Città della Salute e della Scienza, University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - F. Castoldi
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
- Orthopaedic and Traumatology Department, San Luigi Gonzaga Hospital, University of Turin, Regione Gonzole 10, 10043 Orbassano, Italy
| |
Collapse
|
10
|
Schwartz BL, Pithadia DJ, Chen JK. Hypersensitivity to Implanted Metal Devices. CURRENT DERMATOLOGY REPORTS 2023. [DOI: 10.1007/s13671-023-00381-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
11
|
Boutefnouchet T, Vallières F, Delisle J, Benderdour M, Fernandes JC. Lymphocyte transformation test reveals low prevalence of true metal hypersensitivity among pre-operative total knee arthroplasty patients. Knee Surg Sports Traumatol Arthrosc 2022; 30:4123-4133. [PMID: 35380240 DOI: 10.1007/s00167-022-06951-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 03/15/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE The aims of this study were to determine the prevalence of metal hypersensitivity, and identify pre-operative factors which could predict susceptibility to hypersensitivity reactions among patients scheduled for primary total knee arthroplasty (TKA). The present study used a testing method consistent with the recognised biological response to metals. METHODS A prospective cross-sectional analysis of 220 patients was conducted. All patients received a testing protocol using lymphocyte transformation test to evaluate reactivity to possible contents of orthopaedic implants. Test response is interpreted as stimulation index (SI) values. A comprehensive questionnaire was used to evaluate prior exposure. Patients were categorised according to SI values and the odds ratios (OR) were calculated as comparative effect measure for each predetermined prior exposure factor. RESULTS The prevalence of metal sensitivity response was 28% (n = 61) among patients with susceptibility to at least one agent (SI = 2 to 4.9), and 3.2% (n = 7) among patients with true hypersensitivity (SI ≥ 5). The population-weighted prevalence, adjusted for sampling weights of symptomatic knee osteoarthritis, was SI ≥ 5 = 4.7% (95% CI 0.4-11.8%) and SI ≥ 2 = 35.2% (95% CI 24.8-48.6%). Stimulation index levels of response to materials were markedly varied with the highest being aluminium. Female sex, smoking history, cutaneous reaction to jewellery, occupational exposure, and dental procedures were among factors shown to increase the odds of having higher reactivity response to tested metals. Nevertheless, patients with well-functioning prior contralateral TKA did not appear at greater risk of having either sensitivity or susceptibility with odds ratio (OR) = 0.2 (95% CI 0.01-3.2), p: NS and OR = 0.6 (95% CI 0.3-1.2), p: NS, respectively. Prior positive patch test was neither predictor of susceptibility to hypersensitivity OR = 1.2 (95% CI 0.6-2.6) p: NS nor predictor of true hypersensitivity OR = 0.7 (95% CI 0.08-6.1), p: NS. CONCLUSION Among patients scheduled for primary TKA with no prior clinical features of metal allergy the prevalence of true hypersensitivity to at least one metal is just over 3%. Patients are likely to encounter a material to which they have pre-existing susceptibility to hypersensitivity. With certain prior exposure factors, there was increased susceptibility to metal hypersensitivity reaction evoking an acquired condition. LEVEL OF EVIDENCE Level II, prospective cross-sectional study.
Collapse
Affiliation(s)
- Tarek Boutefnouchet
- CIUSSS Nord de L'Ile de Montréal, Hôpital du Sacré-Coeur de Montréal, Jean Talon and Fleury Hospitals, Montreal, QC, Canada.
- University Hospitals Birmingham NHS Trust, Mindelsohn Way, Edgbaston, Birmingham, B15 2GW, UK.
| | - Francis Vallières
- CIUSSS Nord de L'Ile de Montréal, Hôpital du Sacré-Coeur de Montréal, Jean Talon and Fleury Hospitals, Montreal, QC, Canada
| | - Josee Delisle
- CIUSSS Nord de L'Ile de Montréal, Hôpital du Sacré-Coeur de Montréal, Jean Talon and Fleury Hospitals, Montreal, QC, Canada
| | - Mohamed Benderdour
- CIUSSS Nord de L'Ile de Montréal, Hôpital du Sacré-Coeur de Montréal, Jean Talon and Fleury Hospitals, Montreal, QC, Canada
| | - Julio C Fernandes
- CIUSSS Nord de L'Ile de Montréal, Hôpital du Sacré-Coeur de Montréal, Jean Talon and Fleury Hospitals, Montreal, QC, Canada
| |
Collapse
|
12
|
Impact of Preoperative Metal Patch Testing on Surgery Using Metal Implants. Arthroplast Today 2022; 14:170-174. [PMID: 35330665 PMCID: PMC8938599 DOI: 10.1016/j.artd.2022.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 01/18/2022] [Accepted: 02/12/2022] [Indexed: 11/26/2022] Open
Abstract
Background Patients scheduled for metal implant surgery in some facilities in Japan undergo preoperative metal patch testing (MPT). However, few studies have reported the impact of MPT results on scheduled surgery; therefore, the value of preoperative MPT remains unknown. Material and methods In analysis 1,the preoperative MPT results requested by orthopedic surgeons from 4 institutions from 2014 to 2018 were retrospectively analyzed. In analysis 2, the medical records of all patients who underwent total hip arthroplasty, total knee arthroplasty, or total shoulder arthroplasty/reverse shoulder arthroplasty between 2014 and 2018 were collected. The number of patients who underwent MPT and their surgical results were analyzed. Results In analysis 1, MPT was performed on 72 patients during the study period. The overall MPT positivity rate was 26.4% for the entire cohort in analysis 1. In 4 out of 19 MPT-positive cases, the results of MPT changed the treatment plan to use alternative materials or cancel the surgery. In analysis 2, 1087 patients underwent total hip arthroplasty, total knee arthroplasty, and TSA/RSA; only 16 patients underwent MPT. Aseptic loosening occurred postoperatively in 3 patients (0.3%), none of whom had a history of allergy, and none underwent preoperative MPT. Conclusion Metal allergy did not appear to be directly involved in aseptic loosening to any large or meaningful degree in our patient cohort. Only 1.5% of the patients underwent preoperative MPT; therefore, our results suggest this testing had limited benefit or utility. Further studies are needed to determine whether MPT is necessary in preparation for joint replacement.
Collapse
|
13
|
Battaglia AG, Ali-Zade C, Monti L, Al Khawashki H, Winkler H, Del Sel H, Mavrogenis AF, Benzakour T, Drago L, Romanò CL. Metal Hypersensitivity or Missed Periprosthetic Joint Infection? A Critical Review. Orthopedics 2022; 45:e73-e78. [PMID: 34978510 DOI: 10.3928/01477447-20211227-04] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The World Association Against Infection in Orthopedics And Trauma (W.A.I.O.T.) Study Group on Bone And Joint Infection Definitions Metal hypersensitivity (MHS) has been investigated by several authors as a possible reason for painful total joint arthroplasty, with controversial results. Periprosthetic joint infection (PJI) is another possible source of unexplained pain and implant failure that may be difficult to diagnose if not properly investigated. We performed this critical review to assess whether the current literature on MHS includes an adequate diagnostic workup to discern metal allergy from PJI. The results of this review highlight the importance of assessing patients for PJI before making a diagnosis of MHS and emphasize that the methods currently used to exclude PJI are substantially inadequate. Therefore, well-designed clinical trials with adequate diagnostic protocols and definitions of PJI that can differentiate MHS from low-grade PJI are needed. [Orthopedics. 2022;45(2):e73-e78.].
Collapse
|
14
|
Bogdanova-Bennett A, Sagi A, Asopa V, Field RE, Sochart DH. Nickel hypersensitivity and skin patch testing in total hip replacement surgery: a systematic review. EFORT Open Rev 2021; 6:825-838. [PMID: 34760283 PMCID: PMC8559563 DOI: 10.1302/2058-5241.6.210051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Approximately 60,000 cemented femoral stems are implanted in the UK each year with the majority being manufactured from stainless steel containing 10–15% nickel. Nickel hypersensitivity has been reported in up to 13% of the general population and there is a concern that nickel hypersensitivity might adversely affect the outcome of total hip replacement (THR). We reviewed the current literature on the potential link between nickel hypersensitivity and THR complications, and the usefulness of patch testing. We conducted a literature search in PubMed, MEDLINE and EMBASE databases. The level of evidence and the quality of the selected studies were assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the Methodological Index for Non-Randomised Studies tool, respectively. Twenty-six studies met the inclusion criteria, reporting on 1852 patients who underwent primary or revision THR. All studies detailed skin patch testing and recorded prevalence of nickel hypersensitivity from 1.5% to 33.3%. Five studies reported a rise in Nickel hypersensitivity following THR, while four reported a decreased prevalence post-operatively. Eight studies concluded that metal hypersensitivity could have developed following THR, while seven studies did not support a link between metal hypersensitivity and THR complications. Four of the studies recommended routine patch testing pre-operatively, but three others concluded that routine patch testing was not indicated. We have not identified a link between nickel hypersensitivity and THR complications, and the role of patch testing remains unclear. Further large-scale studies would be required to investigate this relationship and to clarify the role of patch testing in facilitating implant selection.
Cite this article: EFORT Open Rev 2021;6:825-838. DOI: 10.1302/2058-5241.6.210051
Collapse
Affiliation(s)
| | - Amit Sagi
- Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK
| | - Vipin Asopa
- Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK
| | - Richard E Field
- Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK
| | - David H Sochart
- Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom, UK
| |
Collapse
|
15
|
Abstract
This review aims to discuss the advantages and disadvantages of zirconia implants compared with titanium implants. Moreover, it intends to review the relevant available long-term literature of these two materials regarding osteointegration, soft-tissue, microbiota, and peri-implantitis, focusing on clinical results. Briefly, titanium implants are a reliable alternative for missing teeth; however, they are not incapable of failure. In an attempt to provide an alternative implant material, implants made from ceramic-derivate products were developed. Owing to its optimal osseointegration competence, biocompatibility, and esthetic proprieties, zirconium dioxide (ZrO2), also known as zirconia, has gained popularity among researchers and clinicians, being a metal-free alternative for titanium implants with its main use in the anterior esthetic zones. This type of implant may present similar osseointegration as those noted on titanium implants with a greater soft-tissue response. Furthermore, this material does not show corrosion as its titanium analog, and it is less susceptible to bacterial adhesion. Lastly, even presenting a similar inflammatory response to titanium, zirconia implants offer less biofilm formation, suggesting less susceptibility to peri-implantitis. However, it is a relatively new material that has been commercially available for a decade; consequently, the literature still lacks studies with long follow-up periods.
Collapse
|
16
|
Rufaqua R, Vrbka M, Hemzal D, Choudhury D, Rebenda D, Křupka I, Hartl M. Analysis of Chemisorbed Tribo-Film for Ceramic-on-Ceramic Hip Joint Prostheses by Raman Spectroscopy. J Funct Biomater 2021; 12:jfb12020029. [PMID: 34062752 PMCID: PMC8167604 DOI: 10.3390/jfb12020029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 04/24/2021] [Accepted: 04/27/2021] [Indexed: 01/03/2023] Open
Abstract
To understand the possible lubricant mechanism in ceramic-on-ceramic hip joint prostheses, biochemical reactions of the synovial fluid and the corresponding frictional coefficients were studied. The experiments were performed in a hip joint simulator using the ball-on-cup configuration with balls and cups made from two types of ceramics, BIOLOX®forte and BIOLOX®delta. Different lubricants, namely albumin, γ-globulin, hyaluronic acid and three model synovial fluids, were studied in the experiments and Raman spectroscopy was used to analyze the biochemical responses of these lubricants at the interface. BIOLOX®delta surface was found less reactive to proteins and model fluid lubricants. In contrast, BIOLOX®forte ball surface has shown chemisorption with both proteins, hyaluronic acid and model fluids imitating total joint replacement and osteoarthritic joint. There was no direct correlation between the measured frictional coefficient and the observed chemical reactions. In summary, the study reveals chemistry of lubricant film formation on ceramic hip implant surfaces with various model synovial fluids and their components.
Collapse
Affiliation(s)
- Risha Rufaqua
- Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; (M.V.); (D.R.); (I.K.); (M.H.)
- Correspondence:
| | - Martin Vrbka
- Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; (M.V.); (D.R.); (I.K.); (M.H.)
| | - Dušan Hemzal
- Department of Condensed Matter Physics, Faculty of Science, Masaryk University, Kotlářská 267/2, 611 37 Brno, Czech Republic;
| | - Dipankar Choudhury
- Nano Mechanics and Tribology Laboratory, Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA;
| | - David Rebenda
- Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; (M.V.); (D.R.); (I.K.); (M.H.)
| | - Ivan Křupka
- Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; (M.V.); (D.R.); (I.K.); (M.H.)
| | - Martin Hartl
- Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; (M.V.); (D.R.); (I.K.); (M.H.)
| |
Collapse
|
17
|
Chua CYX, Liu HC, Di Trani N, Susnjar A, Ho J, Scorrano G, Rhudy J, Sizovs A, Lolli G, Hernandez N, Nucci MC, Cicalo R, Ferrari M, Grattoni A. Carbon fiber reinforced polymers for implantable medical devices. Biomaterials 2021; 271:120719. [PMID: 33652266 DOI: 10.1016/j.biomaterials.2021.120719] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 02/04/2021] [Accepted: 02/10/2021] [Indexed: 12/24/2022]
Abstract
Carbon fibers reinforced polymers (CFRPs) are prolifically finding applications in the medical field, moving beyond the aerospace and automotive industries. Owing to its high strength-to-weight ratio, lightness and radiolucency, CFRP-based materials are emerging to replace traditional metal-based medical implants. Numerous types of polymers matrices can be incorporated with carbon fiber using various manufacturing methods, creating composites with distinct properties. Thus, prior to biomedical application, comprehensive evaluation of material properties, biocompatibility and safety are of paramount importance. In this study, we systematically evaluated a series of novel CFRPs, aiming at analyzing biocompatibility for future development into medical implants or implantable drug delivery systems. These CFRPs were produced either via Carbon Fiber-Sheet Molding Compound or Fused Deposition Modelling-based additive manufacturing. Unlike conventional methods, both fabrication processes afford high production rates in a time-and cost-effective manner. Importantly, they offer rapid prototyping and customization in view of personalized medical devices. Here, we investigate the physicochemical and surface properties, material mutagenicity or cytotoxicity of 20 CFRPs, inclusive of 2 surface finishes, as well as acute and sub-chronic toxicity in mice and rabbits, respectively. We demonstrate that despite moderate in vitro physicochemical and surface changes over time, most of the CFRPs were non-mutagenic and non-cytotoxic, as well as biocompatible in small animal models. Future work will entail extensive material assessment in the context of orthopedic applications such as evaluating potential for osseointegration, and a chronic toxicity study in a larger animal model, pigs.
Collapse
Affiliation(s)
- Corrine Ying Xuan Chua
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA
| | - Hsuan-Chen Liu
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA
| | - Nicola Di Trani
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA; University of Chinese Academy of Science (UCAS), Shijingshan, 19 Yuquan Road, Beijing, 100049, China
| | - Antonia Susnjar
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA
| | - Jeremy Ho
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA; Weill Cornell Medical College, New York, NY, 10065, USA
| | - Giovanni Scorrano
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA; Department of Material Science and Nanoengineering, Rice University, Houston, TX, 77005, USA
| | - Jessica Rhudy
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA
| | - Antons Sizovs
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA
| | - Graziano Lolli
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA; Department of Mechanical and Aerospace Engineering, Polytechnic of Turin, Turin, 10129, Italy
| | - Nathanael Hernandez
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA
| | - Maria Concetta Nucci
- Division of Occupational Medicine, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Via Albertoni 15, Bologna, 40138, Italy
| | - Roberto Cicalo
- D-Verge Srl, Sant'Agata Bolognese, Emilia-Romagna, 40019, Italy
| | - Mauro Ferrari
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA; School of Pharmacy, University of Washington, Seattle, WA, 98195, USA
| | - Alessandro Grattoni
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, 77030, USA; Department of Surgery, Houston Methodist Hospital, Houston, TX, 77030, USA; Department of Radiation Oncology, Houston Methodist Hospital, Houston, TX, 77030, USA.
| |
Collapse
|
18
|
Thomas P, Summer B, Thyssen JP. Hypersensitivity Reactions to Orthopedic Implants. Contact Dermatitis 2021. [DOI: 10.1007/978-3-030-36335-2_80] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
19
|
Dawson-Amoah KG, Waddell BS, Prakash R, Alexiades MM. Adverse Reaction to Zirconia in a Modern Total Hip Arthroplasty with Ceramic Head. Arthroplast Today 2020; 6:612-616.e1. [PMID: 32995410 PMCID: PMC7502561 DOI: 10.1016/j.artd.2020.03.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 02/27/2020] [Accepted: 03/08/2020] [Indexed: 12/28/2022] Open
Abstract
Hypersensitivity reactions to zirconia (ZrO2) or similar ceramics is highly unusual. Owing to the stable oxide formed between the base metal and oxygen, ceramics are considered relatively biologically inert. We report the case of an otherwise healthy 50-year-old woman with a 5-year history of progressively worsening right hip pain who underwent a ceramic-on-polyethylene total hip replacement and subsequently developed hypersensitivity reaction. After metal allergy testing showed her to be highly reactive to zirconium, the femoral head was revised to a custom titanium implant and her symptoms resolved.
Collapse
Affiliation(s)
| | - Bradford S. Waddell
- Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
- Corresponding author. Hospital for Special Surgery LLC, 1 Blachley Road, Stamford, CT 06902, USA. Tel.: +1 404 352 1015.
| | | | | |
Collapse
|
20
|
Abstract
The topic of titanium alloys for dental implants has been reviewed. The basis of the review was a search using PubMed, with the large number of references identified being reduced to a manageable number by concentrating on more recent articles and reports of biocompatibility and of implant durability. Implants made mainly from titanium have been used for the fabrication of dental implants since around 1981. The main alloys are so-called commercially pure titanium (cpTi) and Ti-6Al-4V, both of which give clinical success rates of up to 99% at 10 years. Both alloys are biocompatible in contact with bone and the gingival tissues, and are capable of undergoing osseointegration. Investigations of novel titanium alloys developed for orthopaedics show that they offer few advantages as dental implants. The main findings of this review are that the alloys cpTi and Ti-6Al-4V are highly satisfactory materials, and that there is little scope for improvement as far as dentistry is concerned. The conclusion is that these materials will continue to be used for dental implants well into the foreseeable future.
Collapse
|
21
|
Hassan S, Mercuri LG, Miloro M. Does Metal Hypersensitivity Have Relevance in Patients Undergoing TMJ Prosthetic Replacement? J Oral Maxillofac Surg 2020; 78:908-915. [DOI: 10.1016/j.joms.2020.01.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 01/14/2020] [Indexed: 02/07/2023]
|
22
|
Shanmugham HA, Handa S, De D, Dhillon MS, Aggarwal S. An observational study to determine the sensitizing potential of orthopedic implants. Indian J Dermatol Venereol Leprol 2020; 87:826-830. [PMID: 32134002 DOI: 10.4103/ijdvl.ijdvl_789_18] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2018] [Accepted: 07/01/2019] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Patients who receive orthopedic implants have been shown to develop sensitivity to its components and there are concerns that this sensitivity might lead to contact dermatitis or implant-related problems like loosening and/or failure. The objective of the study was to determine the sensitizing potential of orthopedic implants. METHODS Fifty-four patients undergoing knee, hip, or shoulder replacement surgeries between July 2014 and July 2015 were recruited. Patch tests were performed before the implant surgery with 10 allergens likely to be implicated in metal hypersensitivity. Postimplant patch test was performed 6 months after surgery. A majority of the patch tests were applied on the arms. RESULTS Four positive reactions were recorded in the preimplant patch tests - three positive reactions to nickel and one to chromium. Thirty patients made themselves available for the follow-up patch test. The incidence of new contact sensitivity to components of implants was 13.8% (4/29) at 6 months. One patient who had undergone knee replacement developed eczematous lesions around the knee joint after surgery. This patient tested negative to patch test at both the times. LIMITATIONS Short follow-up duration and performing patch tests on the arms, a site known to elicit less positive patch test response compared to the back in sensitized individuals, are limitations of the study. CONCLUSION There is an increase in the sensitivity to implanted components after 6 months of joint replacement surgery. The incidence of new sensitivity to a component of the implant was 13.8% (4/29). In this context, nickel is a good sensitizer and could sensitize 50% of patients who received a nickel-containing implant.
Collapse
Affiliation(s)
- Haridaran Anand Shanmugham
- Department of Dermatology, Venereology and Leprology Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Sanjeev Handa
- Department of Dermatology, Venereology and Leprology Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Dipankar De
- Department of Dermatology, Venereology and Leprology Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Mandeep Singh Dhillon
- Department of Orthopedic Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Sameer Aggarwal
- Department of Orthopedic Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
23
|
Abstract
Prosthetic loosening has been debated for decades, both in terms of the timing and nature of the triggering events. Multiple radiostereometric studies of hip prostheses have now shown that early migration poses a risk of future clinical failure, but is this enough to explain late clinical loosening?To answer this question, the progression of loosening from initiation to radiographic detection is described; and the need for explanations other than early prosthetic loosening is analysed, such as stress-shielding, particle disease, and metal sensitivity.Much evidence indicates that prosthetic loosening has already been initiated during or shortly after the surgery, and that the subsequent progression of loosening is affected by biomechanical factors, fluid pressure fluctuations and inflammatory responses to necrotic cells and cell fragments, i.e. the concept of late loosening appears to be a misinterpretation of late-detected loosening.Clinical implications: atraumatic surgery and initial prosthetic stability are crucial in ensuring low risk of prosthetic loosening. Cite this article: EFORT Open Rev 2020;5:113-117. DOI: 10.1302/2058-5241.5.190014.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopaedics, Lund University, Lund, Sweden
- Bengt Mjöberg, Västra Vallgatan 29, SE-27135 Ystad, Sweden.
| |
Collapse
|
24
|
Kennon JC, Lee J, Songy C, Shukla D, Cofield RH, Sanchez-Sotelo J, Sperling JW. The effect of patient-reported metal allergies on the outcomes of shoulder arthroplasty. J Shoulder Elbow Surg 2020; 29:296-301. [PMID: 31427231 DOI: 10.1016/j.jse.2019.06.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 05/29/2019] [Accepted: 06/07/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although literature exists regarding hip and knee arthroplasty outcomes in patients with skin allergy to metals, there is minimal information about skin allergy implications on shoulder arthroplasty outcomes. The purpose of this study was to determine the results, complications, and failure rate among patients with a self-reported metal allergy undergoing shoulder arthroplasty. METHODS Fifty-two shoulder arthroplasties were performed at our Institution in 43 patients with self-reported metal allergies. Forty primary and 12 revision shoulder arthroplasties were performed using anatomic (30) and reverse (22) components. Retrospective chart review was performed to determine metal allergy history, implant composition, pain, motion, and complications. Radiographs were reviewed to determine mechanical failure rates. Average follow-up time was 65 months. RESULTS Allergies reported included nickel (37), cobalt chrome (4), copper (2), zinc (1), titanium (1), gold (1), and nonspecific metal allergy (8); 8 patients reported multiple metal allergies. All components implanted in patients with nickel allergies contained nickel. At most recent follow-up, pain was rated as none or mild in 88% of shoulders. Active elevation improved from 80° to 141° and external rotation from 24° to 52°. Two revisions were performed for glenoid loosening (3.8%); both were revision cases with substantial glenoid bone loss. One patient with mild pain had a radiographically loose glenoid component 12 years after anatomic shoulder arthroplasty. CONCLUSION Results from this study suggest that shoulder arthroplasty in patients with self-reported metal allergy provides satisfactory pain relief and improved range of motion with low revision rates.
Collapse
Affiliation(s)
- Justin C Kennon
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Julia Lee
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Chad Songy
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Dave Shukla
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Robert H Cofield
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | | | - John W Sperling
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
25
|
An N, Pourzal S, Luccioli S, Vukmanović S. Effects of diet on skin sensitization by nickel, poison ivy, and sesquiterpene lactones. Food Chem Toxicol 2020; 137:111137. [PMID: 31982450 DOI: 10.1016/j.fct.2020.111137] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 12/20/2019] [Accepted: 01/17/2020] [Indexed: 12/12/2022]
Abstract
Skin contact or exposure to sensitizers often occurs as a consequence of occupational exposures (e.g. poison ivy in forestry), wearing jewelry (e.g. nickel), or use of cosmetics (e.g. fragrances). However, many of the known skin sensitizers or their chemical variants are also consumed orally through foods or other sources. Since oral exposure to antigenic substances can lead to tolerance, consumption of sensitizers may impact the development and potency of skin sensitization, especially if the sensitizer is consumed early in life, prior to the first skin contact. To address this issue, we have reviewed human clinical and epidemiological literature relevant to this subject and evaluated whether early oral exposures to relevant sensitizers, or their chemical variants, are associated with reduced prevalence of skin sensitization to three main allergic sensitizers - nickel, urushiols of poison ivy, and sesquiterpene lactones of chrysanthemum and other plants.
Collapse
Affiliation(s)
- Nan An
- Cosmetics Division, Office of Cosmetics and Colors (OCAC), Center for Food Safety and Applied Nutrition (CFSAN), Food and Drug Administration (FDA), USA
| | - Selma Pourzal
- Cosmetics Division, Office of Cosmetics and Colors (OCAC), Center for Food Safety and Applied Nutrition (CFSAN), Food and Drug Administration (FDA), USA
| | - Stefano Luccioli
- Office of Compliance (OC), Center for Food Safety and Applied Nutrition (CFSAN), Food and Drug Administration (FDA), USA
| | - Stanislav Vukmanović
- Cosmetics Division, Office of Cosmetics and Colors (OCAC), Center for Food Safety and Applied Nutrition (CFSAN), Food and Drug Administration (FDA), USA.
| |
Collapse
|
26
|
Thomas P, Summer B, Thyssen JP. Orthopedic Implants. Contact Dermatitis 2020. [DOI: 10.1007/978-3-319-72451-5_80-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
27
|
Thomas P, Summer B, Thyssen JP. Hypersensitivity Reactions to Orthopedic Implants. Contact Dermatitis 2020. [DOI: 10.1007/978-3-319-72451-5_80-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
28
|
Armonies S, Zajonz D, Treudler R, Roth A, Ghanem M. Long-term outcome after implantation of a nickel-containing cemented hip stem on the right in a patient with type IV sensitization to nickel sulphate. GMS INTERDISCIPLINARY PLASTIC AND RECONSTRUCTIVE SURGERY DGPW 2019; 8:Doc18. [PMID: 32047716 PMCID: PMC6997891 DOI: 10.3205/iprs000144] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Type IV allergies to nickel sulfate, potassium dichromate and/or cobalt chloride are supposed to be associated with aseptic loosening, pain or infections in patients with hip arthroplasty. However, there is debate on any causal relation between type IV sensitization to metals and any of these complications. We report on a patient with suspicion of pre-existing type IV sensitization to nickel sulfate and potassium dichromate who did not show any complications after hip arthroplasty.
Collapse
Affiliation(s)
- Sarah Armonies
- Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany
| | - Dirk Zajonz
- Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany
| | - Regina Treudler
- Department of Dermatology, Venerology and Allergology, University Hospital Leipzig, Germany
| | - Andreas Roth
- Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany
| | - Mohamed Ghanem
- Department of Orthopedics, Traumatology and Plastic Surgery, University Hospital Leipzig, Germany
| |
Collapse
|
29
|
Abstract
There are very few reports of eczema and other prosthetic-related allergic skin complications following arthroplasty. We aimed to assess the risk of eczema after joint replacement.We performed a retrospective population-based cohort study in 2024 joint replacement patients using the Longitudinal Health Insurance Database. For comparison, 8096 controls were selected, with 4 control subjects for each joint replacement patient matched for age, sex, and index year, to assess eczema risk. We examined 14-year cumulative eczema incidence associated with age, sex, immunity, disease history, and joint replacement location.Eczema rates in the joint replacement patients were 38% higher than in the control group (57.90 vs 41.84 per 1000 person-years, respectively). Compared with the control group, joint replacement patients showed a 1.35-fold increased risk of eczema according to the multivariable Cox model (95% Confidence interval [CI] = 1.23-1.49). Knee replacement patients had higher eczema risk compared with the control group (Hazard ratio [HR] = 1.45, 95% CI = 1.33-1.70). Stratified by study period, the joint replacement cohort had a higher eczema risk after the 3-month follow-up.Our study revealed that joint arthroplasty increased risk of eczema in this 14-year follow-up study, and this was not related to personal atopic history or gender.
Collapse
Affiliation(s)
- Po-Yuan Wu
- Department of Dermatology, China Medical University Hospital
- School of Medicine, China Medical University
| | | | - Chun-Hao Tsai
- School of Medicine, China Medical University
- Department of Orthopedics, China Medical University Hospital
- Department of Sports Medicine/School of Medicine, China Medical University, Taichung, Taiwan
| |
Collapse
|
30
|
Richards LJ, Streifel A, Rodrigues JM. Utility of Patch Testing and Lymphocyte Transformation Testing in the Evaluation of Metal Allergy in Patients with Orthopedic Implants. Cureus 2019; 11:e5761. [PMID: 31723520 PMCID: PMC6825456 DOI: 10.7759/cureus.5761] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Total joint arthroplasties are increasingly common orthopedic procedures performed throughout the United States. Implant failure after these procedures occurs due to a number of causes such as infection or mechanical problems, with metal hypersensitivity being an area of growing interest. The nature and mechanism of a causative relationship between metal hypersensitivity and implant failure have been unclear as it is not known whether implant failure occurs due to a previous metal allergy or metal allergy results from secondary sensitization via metal exposure in existing failing implants. Overall, there appears to be growing support and evidence for metal-hypersensitive patients having worse outcomes with regard to total hip and knee arthroplasties. However, there are conflicting recommendations (outside of Nuss procedures) for pre-implant testing for metal hypersensitivity as testing has not consistently been shown to change patient outcomes.
Collapse
Affiliation(s)
- Logan J Richards
- Miscellaneous, University of North Dakota School of Medicine and Health Sciences, Bismarck, USA
| | - Alexandra Streifel
- Internal Medicine, University of North Dakota School of Medicine and Health Sciences, Bismarck, USA
| | - Jonathan M Rodrigues
- Internal Medicine, University of North Dakota School of Medicine and Health Sciences, Bismarck, USA
| |
Collapse
|
31
|
Christiansen RJ, Münch HJ, Bonefeld CM, Thyssen JP, Sloth JJ, Geisler C, Søballe K, Jellesen MS, Jakobsen SS. Cytokine Profile in Patients with Aseptic Loosening of Total Hip Replacements and Its Relation to Metal Release and Metal Allergy. J Clin Med 2019; 8:jcm8081259. [PMID: 31434199 PMCID: PMC6723430 DOI: 10.3390/jcm8081259] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 08/06/2019] [Accepted: 08/09/2019] [Indexed: 12/13/2022] Open
Abstract
Metal release from total hip replacements (THRs) is associated with aseptic loosening (AL). It has been proposed that the underlying immunological response is caused by a delayed type IV hypersensitivity-like reaction to metals, i.e., metal allergy. The purpose of this study was to investigate the immunological response in patients with AL in relation to metal release and the prevalence of metal allergy. THR patients undergoing revision surgery due to AL or mechanical implant failures were included in the study along with a control group consisting of primary THR patients. Comprehensive cytokine analyses were performed on serum and periimplant tissue samples along with metal analysis using inductive coupled plasma mass spectrometry (ICP-MS). Patient patch testing was done with a series of metals related to orthopedic implant. A distinct cytokine profile was found in the periimplant tissue of patients with AL. Significantly increased levels of the proinflammatory cytokines IL-1β, IL-2, IL-8, IFN-γ and TNF-α, but also the anti-inflammatory IL-10 were detected. A general increase of metal concentrations in the periimplant tissue was observed in both revision groups, while Cr was significantly increased in patient serum with AL. No difference in the prevalence of metal sensitivity was established by patch testing. Increased levels of IL-1β, IL-8, and TNF-α point to an innate immune response. However, the presence of IL-2 and IFN-γ indicates additional involvement of T cell-mediated response in patients with AL, although this could not be detected by patch testing.
Collapse
Affiliation(s)
- Rune J Christiansen
- Department of Mechanical Engineering, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
- Department of Immunology and Microbiology, University of Copenhagen, DK-2200 Copenhagen, Denmark.
| | - Henrik J Münch
- Institute of Clinical Medicine-Orthopedic Surgery, Aarhus University, DK-8000 Aarhus C, Denmark
| | - Charlotte M Bonefeld
- Department of Immunology and Microbiology, University of Copenhagen, DK-2200 Copenhagen, Denmark
| | - Jacob P Thyssen
- Institute of Clinical Medicine, Copenhagen University, Gentofte Hospital, DK-2900 Hellerup, Denmark
| | - Jens J Sloth
- National Food Institute, Research Group on Nanobio Science, Technical University of Denmark, DK-2860 Søborg, Denmark
| | - Carsten Geisler
- Department of Immunology and Microbiology, University of Copenhagen, DK-2200 Copenhagen, Denmark
| | - Kjeld Søballe
- Institute of Clinical Medicine-Orthopedic Surgery, Aarhus University, DK-8000 Aarhus C, Denmark
| | - Morten S Jellesen
- Department of Mechanical Engineering, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark
| | - Stig S Jakobsen
- Institute of Clinical Medicine-Orthopedic Surgery, Aarhus University, DK-8000 Aarhus C, Denmark.
| |
Collapse
|
32
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
33
|
Islam LN, Rahman F, Hossain A. Serum Immunoglobulin Levels and Complement Function of Tannery Workers in Bangladesh. J Health Pollut 2019; 9:190308. [PMID: 30931168 PMCID: PMC6421957 DOI: 10.5696/2156-9614-9.21.190308] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 02/03/2019] [Indexed: 06/09/2023]
Abstract
BACKGROUND Occupational exposures to chromium (Cr), which can have adverse effects on immune function, have not yet been extensively investigated. Hexavalent chromium (Cr (VI)), used in mineral tanning processes, poses a threat to the health of workers in the leather tanning industry. OBJECTIVES The aim of the present study was to evaluate the effects of long-term Cr exposure on the physical health and immunological parameters of male tannery workers in Bangladesh compared with a control group. METHODS A health examination was performed with tannery workers (N=195) and control subjects (N=125) by physicians, demographic data were recorded in questionnaires and peripheral blood samples were collected. Serum Cr levels were analyzed by an atomic absorption spectrophotometer (AAS), immunoglobulin (Ig)G, IgA, and complement components C3 and C4 were determined by nephelometry, IgE was measured by sandwich enzyme-linked immunosorbent assay and complement function was assayed by bactericidal activity. RESULTS The mean duration of work exposure for the tanners was 9.4±7.1 years. Their body mass index (21.8±3.0 kg/m2), was not significantly different from the controls (22.7±3.2 kg/m2). The mean serum level of Cr in 30 long-term exposed tannery workers (26.97±21.11 μg/dL) was significantly higher than that of 30 randomly selected control subjects (7.38±6.81 μg/dL). The tannery workers had rough skin, rashes, itchy and decolorized skin, allergic diseases and respiratory illness, and had significantly lower levels of serum IgG, IgA, C3 and C4, but significantly higher levels of IgE than the controls. IgG, IgA and C3 levels were all inversely associated with Cr, while IgG, IgE and bactericidal activity showed an inverse correlation with duration of exposure. CONCLUSIONS The results of the present study suggest that chronic exposure to Cr is associated with impaired immune function in male tannery workers. PARTICIPANT CONSENT Obtained. ETHICS APPROVAL The present study was approved by the Ethical Review Committee of the faculty of Biological Sciences, University of Dhaka, Bangladesh. COMPETING INTERESTS The authors declare no competing financial interests.
Collapse
Affiliation(s)
- Laila N. Islam
- Department of Biochemistry and Molecular Biology, University of Dhaka, Dhaka, Bangladesh
| | - Fahimur Rahman
- Department of Biochemistry and Molecular Biology, University of Dhaka, Dhaka, Bangladesh
| | - Aktar Hossain
- Department of Biochemistry and Molecular Biology, University of Dhaka, Dhaka, Bangladesh
| |
Collapse
|
34
|
Abstract
RATIONALE Due to the low incidence and lack of effective diagnostic measures for the diagnosis of metal allergy in patients undergoing total joint arthroplasty (TJA), diagnosis relies mainly on the exclusion of other causes, in particular infection. It remains a relatively unpredictable and poorly understood cause of implant failure. At present, skin patch testing, leukocyte migration inhibition test (LMIT) and lymphocyte transformation tests (LTT) are being commonly used to assess metal hypersensitivity.This report presents both a case and literature review. PATIENT CONCERNS A 61-year-old female patient experienced continuous swelling and pain in the right knee joint for 9 months after a right-side total knee arthroplasty (TKA). DIAGNOSES We believe this is the case report of metal allergy in TKA. The following were the reasons for this. First, no definite symptoms of infection during revision arthroplasty were observed, but with obvious hyperplasia of synovium. Furthermore, a frozen biopsy revealed an extremely low neutrophil count, which was considered to be caused by chronic inflammation. Second, the results of repeated post-operation reexaminations indicate a clear increase in the number of eosinophils, while no bacteria were found in the tissue bacterial smear performed during the operation. Third, improvements were clearly observed in the patient following synovectomy, revision of the polyethylene insert and anti-anaphylactic treatment. INTERVENTIONS The patient underwent synovectomy, revision of the polyethylene insert and anti-anaphylactic treatment. OUTCOMES The patient's right knee remained mildly swollen; however, the pain has been relieved significantly. The range of motion could achieve 0 degrees of extension and 90 degrees of flexion. LESSONS No consensus has been reached about the best diagnostic criteria for this disease, and most physicians would consider it to be a possibility when other diseases including periprosthetic joint infection (PJI) have been excluded. Although this case followed the same course, the outcome following synovectomy and anti-anaphylactic treatment further confirmed our hypothesis.
Collapse
|
35
|
Vierra BM, Blumenthal SR, Amanatullah DF. Modularity in Total Hip Arthroplasty: Benefits, Risks, Mechanisms, Diagnosis, and Management. Orthopedics 2017; 40:355-366. [PMID: 28598491 DOI: 10.3928/01477447-20170606-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Accepted: 11/07/2016] [Indexed: 02/03/2023]
Abstract
Modular implants are currently widely used in total hip arthroplasty because they give surgeons versatility during the operation, allow for easier revision surgery, and can be adjusted to better fit the anatomy of the specific patient. However, modular implants, specifically those that have metal-on-metal junctions, are susceptible to crevice and fretting corrosion. This can ultimately cause implant failure, inflammation, and adverse local tissue reaction, among other possible side effects. Surgeons should be aware of the possibility of implant corrosion and should follow a set of recommended guidelines to systematically diagnose and treat patients with corroded implants. Ultimately, surgeons will continue to use modular implants because of their widespread benefits. However, more research is needed to determine how to minimize corrosion and the negative side effects that have been associated with modular junctions in total hip arthroplasty. [Orthopedics. 2017; 40(6):355-366.].
Collapse
|
36
|
Christensen TJ, Samant SA, Shin AY. Making Sense of Metal Allergy and Hypersensitivity to Metallic Implants in Relation to Hand Surgery. J Hand Surg Am 2017; 42:737-746. [PMID: 28709788 DOI: 10.1016/j.jhsa.2017.06.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Accepted: 06/12/2017] [Indexed: 02/02/2023]
Abstract
All metals implanted into a biological system undergo some degree of corrosion depending upon its composition. The electrochemical process of corrosion produces free metal ions, which may activate the host's immune system through a variety of mechanisms. Whereas dermal metal hypersensitivity is common, affecting 10% to 15% of the population, the immune reaction from implanted metals is much less common (< 0.1%), but has been associated with metal allergy and hypersensitivity producing a multitude of patient symptoms. Superficial symptoms may be mild to severe forms of dermatitis, urticaria, pruritus, and vasculitis, whereas deep sequelae include metallosis-related pseudotumor, implant loosening, and joint stiffness. Currently, there are clinical tests to evaluate patients for metal hypersensitivity, but there is little agreement regarding the ideal timing and clinical situation prompting the work-up of a patient for a metal allergy or hypersensitivity. An understanding of the epidemiology, etiology, basic science, diagnostic testing, and treatment of patients with suspected metal allergy, as it pertains to the current literature, will aid orthopedic and plastic surgeons of all subspecialties in the management of patients requiring metallic implants.
Collapse
Affiliation(s)
| | | | - Alexander Y Shin
- Department of Orthopedic Surgery, Division of Hand Surgery, Mayo Clinic, Rochester, MN.
| |
Collapse
|
37
|
Abstract
Osteosynthesis materials or artificial joint replacement make part of clinical routine. In case of complaints mostly mechanical causes or infections are found. Metals like nickel, chromium and cobalt or bone cement components like acrylates and gentamicine may however potentially cause intolerance reactions to implants. Correspondingly, eczema, delayed wound/bone healing, recurrent effusion, pain or implant loosening have been described as manifestation of implant allergy. In contrast to the high incidence of cutaneous metal allergy, allergies associated with implants are rare. Diagnosis of metal implant allergy is based on excluding differential diagnoses – in particular infection – and on a combined approach of allergological diagnostics by patch test and histopathology of periimplant tissue. Risk factors for allergic sensitization to implants or triggering periimplant allergic reactions in the case of preexisting cutaneous metal allergy are unknown. Despite the risk of developing complications being unclear, titanium-based osteosynthesis materials are recommended for metal-allergic patients and the use of metal-metal couplings in arthroplasty is rather not recommended for such patients. If a regular, potentially applicable CoCr-polyethylene articulation is preferred, the patient has to be well informed and has to give his written consent.
Collapse
|
38
|
Teo WZW, Schalock PC. Metal Hypersensitivity Reactions to Orthopedic Implants. Dermatol Ther (Heidelb) 2017; 7:53-64. [PMID: 27995484 PMCID: PMC5336431 DOI: 10.1007/s13555-016-0162-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Indexed: 01/08/2023] Open
Abstract
Total hip and knee replacement surgery using metal alloy devices is common. Type IV allergic reactions to these implants occur, though infrequently. While uncommon, peri-implant metal allergic reactions may cause significant morbidity for the affected individual-including aseptic loosening, pseudotumor formation and frank device failure. It is challenging to predict who will have these reactions, even in those with established pre-implant metal allergy. At this time, the scientific literature clearly supports few conclusions. Despite this, we believe several conclusions can be made: routine pre-implant testing in asymptomatic individuals is not indicated; listen to patient's concerns about metal allergy if the concern arises; patch testing is probably the best pre- and post-implant screening test; post-implantation testing is controversial and even positive LTT or patch test does not definitively diagnose morbidity from a metal allergy; and complete recovery following revision placement of an immunologically inert device is diagnostic. More research is needed to scientifically approach this issue.
Collapse
Affiliation(s)
- Wendy Z W Teo
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA
| | - Peter C Schalock
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
| |
Collapse
|
39
|
Atkinson HDE. The negatives of knee replacement surgery: complications and the dissatisfied patient. ORTHOPAEDICS AND TRAUMA 2017; 31:25-33. [DOI: 10.1016/j.mporth.2016.09.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
40
|
Ajwani SH, Charalambous CP. Availability of Total Knee Arthroplasty Implants for Metal Hypersensitivity Patients. Knee Surg Relat Res 2016; 28:312-318. [PMID: 27894179 PMCID: PMC5134788 DOI: 10.5792/ksrr.16.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 04/19/2016] [Accepted: 05/19/2016] [Indexed: 12/18/2022] Open
Abstract
Purpose To provide information on the type of "hypersensitivity-friendly" components available for primary total knee arthroplasty (TKA) in the current market. Materials and Methods Implant manufactures were identified using the 2013 National Joint Registries of the United Kingdom and Sweden and contacted to obtain information about the products they offer for patients with metal hypersensitivity. Results Information on 23 TKA systems was provided by 13 implant manufacturers. Of these, 15 systems had options suitable for metal hypersensitivity patients. Two types of "hypersensitivity-friendly" components were identified: 10 implants were cobalt chrome prostheses with a "hypersensitivity-friendly" outer coating and 5 implants were made entirely from non-cobalt chrome alloys. Conclusions The results of this study suggest that several hypersensitivity TKA options exist, some of which provide the same designs and surgical techniques as the conventional implants. The information in this study can guide TKA surgeons in making informed choices about implants and identifying implants that could be examined in future controlled studies comparing outcomes between "hypersensitivity-friendly" and conventional implants.
Collapse
Affiliation(s)
- Sanil Harji Ajwani
- Department of Orthopaedics, Blackpool Teaching Hospitals NHS Foundation Trust, Blackpool, UK
| | - Charalambos P Charalambous
- Department of Orthopaedics, Blackpool Teaching Hospitals NHS Foundation Trust, Blackpool, UK.,School of Medicine and Dentistry, University of Central Lancashire, Preston, UK.,Institute of Inflammation and Repair, School of Medical and Human Sciences, University of Manchester, Manchester, UK
| |
Collapse
|
41
|
Abstract
INTRODUCTION The use of zirconia in medicine and dentistry has rapidly expanded over the past decade, driven by its advantageous physical, biological, esthetic, and corrosion properties. Zirconia orthopedic hip replacements have shown superior wear-resistance over other systems; however, risk of catastrophic fracture remains a concern. In dentistry, zirconia has been widely adopted for endosseous implants, implant abutments, and all-ceramic crowns. Because of an increasing demand for esthetically pleasing dental restorations, zirconia-based ceramic restorations have become one of the dominant restorative choices. Areas covered: This review provides an updated overview of the applications of zirconia in medicine and dentistry with a focus on dental applications. The MEDLINE electronic database (via PubMed) was searched, and relevant original and review articles from 2010 to 2016 were included. Expert commentary: Recent data suggest that zirconia performs favorably in both orthopedic and dental applications, but quality long-term clinical data remain scarce. Concerns about the effects of wear, crystalline degradation, crack propagation, and catastrophic fracture are still debated. The future of zirconia in biomedical applications will depend on the generation of these data to resolve concerns.
Collapse
Affiliation(s)
- Yen-Wei Chen
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Joelle Moussi
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Jeanie L Drury
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - John C Wataha
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| |
Collapse
|
42
|
Middleton S, Toms A. Allergy in total knee arthroplasty: a review of the facts. Bone Joint J 2016; 98-B:437-41. [PMID: 27037424 DOI: 10.1302/0301-620x.98b4.36767] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Accepted: 10/21/2015] [Indexed: 12/18/2022]
Abstract
We explored the literature surrounding whether allergy and hypersensitivity has a clinical basis for implant selection in total knee arthroplasty (TKA). In error, the terms hypersensitivity and allergy are often used synonymously. Although a relationship is present, we could not find any evidence of implant failure due to allergy. There is however increasing basic science that suggests a link between loosening and metal ion production. This is not an allergic response but is a potential problem. With a lack of evidence logically there can be no justification to use 'hypoallergenic' implants in patients who have pre-existing skin sensitivity to the metals used in TKA.
Collapse
Affiliation(s)
- S Middleton
- Royal Devon and Exeter Hospitals Foundation Trust, Barrack Rd, Exeter, EX2 5DW, UK
| | - A Toms
- Royal Devon and Exeter Hospitals Foundation Trust, Barrack Rd, Exeter, EX2 5DW, UK
| |
Collapse
|
43
|
Razak A, Ebinesan AD, Charalambous CP. Metal Hypersensitivity in Patients with Conventional Orthopaedic Implants. JBJS Rev 2016; 2:01874474-201402000-00001. [PMID: 27490934 DOI: 10.2106/jbjs.rvw.m.00082] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Arif Razak
- Department of Orthopaedic Surgery, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, FY3 8NR, United Kingdom
| | | | | |
Collapse
|
44
|
Allergy to Surgical Implants. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE 2016; 3:683-95. [PMID: 26362550 DOI: 10.1016/j.jaip.2015.07.011] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 07/06/2015] [Accepted: 07/07/2015] [Indexed: 01/26/2023]
Abstract
Surgical implants have a wide array of therapeutic uses, most commonly in joint replacements, but also in repair of pes excavatum and spinal disorders, in cardiac devices (stents, patches, pacers, valves), in gynecological implants, and in dentistry. Many of the metals used are immunologically active, as are the methacrylates and epoxies used in conjunction with several of these devices. Allergic responses to surgical components can present atypically as failure of the device, with nonspecific symptoms of localized pain, swelling, warmth, loosening, instability, itching, or burning; localized rash is infrequent. Identification of the specific metal and cement components used in a particular implant can be difficult, but is crucial to guide testing and interpretation of results. Nickel, cobalt, and chromium remain the most common metals implicated in implant failure due to metal sensitization; methacrylate-based cements are also important contributors. This review will provide a guide on how to assess and interpret the clinical history, identify the components used in surgery, test for sensitization, and provide advice on possible solutions. Data on the pathways of metal-induced immune stimulation are included. In this setting, the allergist, the dermatologist, or both have the potential to significantly improve surgical outcomes and patient care.
Collapse
|
45
|
Gibon E, Amanatullah DF, Loi F, Pajarinen J, Nabeshima A, Yao Z, Hamadouche M, Goodman SB. The biological response to orthopaedic implants for joint replacement: Part I: Metals. J Biomed Mater Res B Appl Biomater 2016; 105:2162-2173. [PMID: 27328111 DOI: 10.1002/jbm.b.33734] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 04/19/2016] [Accepted: 06/01/2016] [Indexed: 12/12/2022]
Abstract
Joint replacement is a commonly performed, highly successful orthopaedic procedure, for which surgeons have a large choice of different materials and implant designs. The materials used for joint replacement must be both biologically acceptable to minimize adverse local tissue reactions, and robust enough to support weight bearing during common activities of daily living. Modern joint replacements are made from metals and their alloys, polymers, ceramics, and composites. This review focuses on the biological response to the different biomaterials used for joint replacement. In general, modern materials for joint replacement are well tolerated by the body as long as they are in bulk (rather than in particulate or ionic) form, are mechanically stable and noninfected. If the latter conditions are not met, the prosthesis will be associated with an acute/chronic inflammatory reaction, peri-prosthetic osteolysis, loosening and failure. This article (Part 1 of 2) is dedicated to the use of metallic devices in orthopaedic surgery including the associated biological response to metallic byproducts is a review of the basic science literature regarding this topic. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2162-2173, 2017.
Collapse
Affiliation(s)
- Emmanuel Gibon
- Department of Orthopaedic Surgery, Stanford University, Stanford, California.,Laboratoire de Biomécanique et Biomatériaux Ostéo-Articulaires - UMR CNRS 7052, Faculté de Médecine - Université Paris7, Paris, France.,Department of Orthopaedic Surgery, Hopital Cochin, APHP, Université Paris5, Paris, France
| | - Derek F Amanatullah
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Florence Loi
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Jukka Pajarinen
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Akira Nabeshima
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Zhenyu Yao
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Moussa Hamadouche
- Department of Orthopaedic Surgery, Hopital Cochin, APHP, Université Paris5, Paris, France
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| |
Collapse
|
46
|
Vasconcelos DM, Santos SG, Lamghari M, Barbosa MA. The two faces of metal ions: From implants rejection to tissue repair/regeneration. Biomaterials 2016; 84:262-275. [DOI: 10.1016/j.biomaterials.2016.01.046] [Citation(s) in RCA: 64] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 01/20/2016] [Accepted: 01/21/2016] [Indexed: 12/20/2022]
|
47
|
Weiser MC, Chen DD. Revision for taper corrosion at the neck-body junction following total hip arthroplasty: pearls and pitfalls. Curr Rev Musculoskelet Med 2016; 9:75-83. [PMID: 26810063 DOI: 10.1007/s12178-016-9322-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The management of the patient with a recalled, modular neck-body total hip arthroplasty can be complex, as it involves a combination of clinical, technical, and medicolegal challenges. Management begins with a thorough history and physical exam, radiographic evaluation, infection workup, and serum metal ion levels. Three-dimensional imaging is obtained based on patient symptomatology and metal ion levels and is used to evaluate for the presence of an adverse local tissue response as well as the integrity of the existing soft tissue envelope. The decision to perform revision surgery is based on a combination of patient symptomatology, laboratory values, and imaging findings. Revision surgery involves the entire armamentarium of femoral revision techniques, and the acetabulum may need to be revised at the surgeon's discretion. The femoral implant can often be removed without disrupting the femoral bone envelope; however, the surgeon should have a low threshold to perform an extended trochanteric osteotomy.
Collapse
Affiliation(s)
- Mitchell C Weiser
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, 9th Floor, Box 1188, New York, NY, 10029, USA.
| | - Darwin D Chen
- Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, 9th Floor, Box 1188, New York, NY, 10029, USA.
| |
Collapse
|
48
|
Allergic reactions in arthroplasty: myth or serious problem? INTERNATIONAL ORTHOPAEDICS 2015; 40:239-44. [PMID: 26526701 DOI: 10.1007/s00264-015-3001-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 09/14/2015] [Indexed: 12/20/2022]
Abstract
PURPOSE The purpose of this study was to determine the prevalence of sensitisation to chromium, cobalt, nickel, or a cement component in patients who received endoprosthetic surgery at our institution. Also, we aimed to assess the portion related to allergic reactions in endoprosthetic revisions and to follow-up those patients after allergic reaction related revisions. METHODS We selected patients with a pre-operative known sensitisation to chromium, cobalt, nickel, or a cement component for a post-operative allergic reaction. All patients who received revision surgery because of a potential allergic reaction were followed up post revision surgery. RESULTS Eight hundred fifty-five patients were pre-operative known to have a sensitisation to chromium, cobalt, nickel, or a cement component. Six hundred eighty-two patients (79.8 %) received a primary arthroplasty, and 173 patients (20.2 %) received a revision surgery. Seventeen patients (2.0 %) were revised because of allergic reactions. Allergic reactions were the cause for approximately 0.2 % of all endoprosthetic revisions and for 9.8 % of revisions in patients with sensitisation to one of the reviewed components. Potential allergens were strictly avoided in the replaced prosthesis. Outcome scores improved post-operatively. CONCLUSIONS The allergic patient should be thoroughly informed about potential reactions resulting from implant choice. Our study can serve as risk assessments by quantifying the incidence of allergic reactions due to endoprosthetic treatment.
Collapse
|
49
|
Material Science in Cervical Total Disc Replacement. BIOMED RESEARCH INTERNATIONAL 2015; 2015:719123. [PMID: 26523281 PMCID: PMC4615218 DOI: 10.1155/2015/719123] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Accepted: 09/17/2015] [Indexed: 12/12/2022]
Abstract
Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.
Collapse
|
50
|
A case of unilateral linear lichen planus: related to orthopedic prosthesis or not? Postepy Dermatol Alergol 2015; 32:310-1. [PMID: 26366158 PMCID: PMC4565834 DOI: 10.5114/pdia.2015.48046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2014] [Revised: 08/25/2014] [Accepted: 09/10/2014] [Indexed: 11/24/2022] Open
|