1
|
Lawlor K, Clausen J, Johnston A, Edge A, Wolff K, Castrignanò E, Couchman L. A review of analytical parameters in 'rapid' liquid chromatographic methods for bioanalysis: Can we do better? J Chromatogr A 2024; 1721:464803. [PMID: 38547680 DOI: 10.1016/j.chroma.2024.464803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 02/22/2024] [Accepted: 03/06/2024] [Indexed: 04/13/2024]
Abstract
Rapid bioanalysis is beneficial to many applications. However, how 'rapid' a method is, or could be, is often an unanswered question. In this statistical review, the authors have assessed multiple pre-analytical (i.e. sample preparation), and analytical method parameters specifically for liquid chromatography to assist researchers in developing and validating 'rapid' bioanalytical methods. We restricted the search to urine and plasma matrices only. Data were extracted from over 2,000 recent studies and evaluated to assess how these parameters affected the 'on-instrument' analysis time. In addition to methods using ultra-violet (UV) detection, there were a large number of mass spectrometric (MS) methods, allowing additional review of the differences between high- and low-resolution MS on analysis time. We observed that most (N = 922, 70 %) methods used 5 or 10 cm columns, and that whilst uptake of ultra-high performance (U)HPLC columns was good, the use of sub-5 cm columns and/or flow rates in excess of 1 mL/min was incredibly rare (N = 25, 3 %). The detector of choice for quantitative (U)HPLC-MS remains the triple quadrupole, although a number of groups report the use of high-resolution MS for such methods.
Collapse
Affiliation(s)
- K Lawlor
- Department of Analytical, Environmental and Forensic Sciences, King's College London, London, SE1 9NH, UK; Analytical Services International, St. George's University of London, Cranmer Terrace, London, SW17 0RE, UK.
| | - J Clausen
- Analytical Services International, St. George's University of London, Cranmer Terrace, London, SW17 0RE, UK
| | - A Johnston
- Analytical Services International, St. George's University of London, Cranmer Terrace, London, SW17 0RE, UK
| | - A Edge
- Avantor Sciences, The Markham Centre, Station Road, Theale, Reading, RG7 4PE
| | - K Wolff
- Department of Analytical, Environmental and Forensic Sciences, King's College London, London, SE1 9NH, UK; Drug Control Centre, King's College London, London, SE1 9NH, UK
| | - E Castrignanò
- Department of Analytical, Environmental and Forensic Sciences, King's College London, London, SE1 9NH, UK; Drug Control Centre, King's College London, London, SE1 9NH, UK
| | - L Couchman
- Department of Analytical, Environmental and Forensic Sciences, King's College London, London, SE1 9NH, UK; Analytical Services International, St. George's University of London, Cranmer Terrace, London, SW17 0RE, UK
| |
Collapse
|
2
|
Enhanced chromatographic efficiency obtained with vacuum jacketed columns facilitates the rapid UHPLC/MS/MS-based analysis of fasiglifam in rat plasma. Talanta 2023; 254:124089. [PMID: 36459869 DOI: 10.1016/j.talanta.2022.124089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 11/03/2022] [Accepted: 11/05/2022] [Indexed: 11/15/2022]
Abstract
The use of vacuum jacketed LC columns (VJC) to minimize on- and post-column band broadening to maximize chromatographic performance has been evaluated as a potential route to improved high throughput (HT) analysis. Here the use of the "VJC" approach has been applied to the HT bioanalysis of the antidiabetic GPR40 agonist drug fasiglifam in rat plasma samples obtained following a 5 mg/kg IV dose. The data obtained from a 1 minute VJC/MS-based analysis showed significant improvements compared to that from a conventional 2 minute UHPLC method for the drug. Notably, using VJC/MS with the rapid 1 min analysis provided a ca. 50% reduction in peak width coupled with a 2-5 fold higher peak response whilst doubling analytical throughput when compared to a conventional UHPLC/MS method. In addition, the increased resolution provided by the VJC system also improved the separation of fasiglifam from common matrix interferences such as co-extracted phospholipids thereby reducing the potential for matrix effects. The concatenation of these improvements suggests that the VJC approach may indeed provide a pathway to more sensitive, robust and high throughput drug bioanalysis, with particular advantages for drug discovery applications.
Collapse
|
3
|
Freitas C, Machado LS, Pereira I, da Silva RR, dos Santos GF, Chaves AR, Simas RC, Lima GS, Vaz BG. Assessing organophosphorus and carbamate pesticides in maize samples using MIP extraction and PSI-MS analyzes. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY 2022; 59:2510-2515. [PMID: 35602426 PMCID: PMC9114180 DOI: 10.1007/s13197-022-05464-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 02/07/2022] [Accepted: 04/03/2022] [Indexed: 06/03/2023]
Abstract
The indiscriminate utilization of agrochemicals causes environmental and animal life impacts. In this regard, methodologies have been developed to offer efficiency and quickness for agrochemicals detection. Due to their selectivity and molecular recognition sites, Molecular Imprinted Polymer (MIPs) have been widely employed in some areas, including biotechnology, waste analyses, foodstuff, biological fluids, and others. This work proposed developing a method to determine aminocarb, pirimicarb, dimethoate, omethoate, pyridaphenthion, and fenitrothion pesticides using molecularly imprinted polymer combined with solid-phase extraction (MIP-SPE) for clean-up and paper spray ionization mass spectrometry for their analysis. Extractions analysis for Aminocarb, Pirimicarb, and Omethoate using MIP-SPE showed better performance when compared with MIP and NIP. The R 2 values were found with R 2 > 0.98 for all pesticides, and LODs and LOQs values were 50 and 100 µg kg-1, respectively. The precision and accuracy were assessed at three concentration levels-low, medium, and high. The precision values (interday and intraday) were below 10%, and the variation of recovery was between 80 and 120% for all pesticides. Therefore, it was possible to verify the presence of two carbamates and five organophosphorus without the necessity of preconcentration samples with precision and good recovery. Supplementary Information The online version contains supplementary material available at 10.1007/s13197-022-05464-7.
Collapse
Affiliation(s)
- Carla Freitas
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | - Lucas S. Machado
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | - Igor Pereira
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | - Rodolfo R. da Silva
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | | | - Andrea R. Chaves
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | - Rosineide C. Simas
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | - Gesiane S. Lima
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| | - Boniek G. Vaz
- Chemistry Institute, Federal University of Goiás, Goiânia, GO 74690-900 Brazil
| |
Collapse
|
4
|
Foest D, Knodel A, Brandt S, Franzke J. Coupling paper spray ionization with the flexible microtube plasma for the determination of low polar biomarkers in mass spectrometry. Anal Chim Acta 2022; 1201:339619. [DOI: 10.1016/j.aca.2022.339619] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 01/21/2022] [Accepted: 02/14/2022] [Indexed: 11/15/2022]
|
5
|
Ramalho RR, Pereira I, da S. Lima G, dos Santos GF, Maciel LI, Simas RC, Vaz BG. Fumonisin B1 analysis in maize by Molecularly Imprinted Polymer Paper Spray Ionization Mass Spectrometry (MIP-PSI-MS). J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2021.104362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
6
|
Seró R, Ayala-Cabrera J, Santos F, Moyano E. Paper spray-atmospheric pressure photoionization-high resolution mass spectrometry for the direct analysis of neutral fluorinated compounds in waterproof impregnation sprays. Anal Chim Acta 2022; 1204:339720. [DOI: 10.1016/j.aca.2022.339720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 03/07/2022] [Accepted: 03/09/2022] [Indexed: 11/30/2022]
|
7
|
Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening. Molecules 2022; 27:molecules27030945. [PMID: 35164211 PMCID: PMC8840626 DOI: 10.3390/molecules27030945] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/26/2022] [Accepted: 01/28/2022] [Indexed: 02/06/2023] Open
Abstract
Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ionization without additional pretreatment are vital in these fields. Many efforts have been devoted to modifying various ambient ionization techniques to simplify the procedures and improve the robustness and sensitivity of the methods. Here, we demonstrate the implementation of rigid spherical sampler probes to improve the robustness of touch spray ionization mass spectrometry. The sphericity of the probes increases the stability of the cone-jet mode of electrospray, reduces the requirements for fine positioning of a sampler in the ion source, and decreases the possibility of corona discharge occurrence. The utilization of spherical sampler probes allows fast, non-invasive sampling, followed by rapid analysis for various drugs of different chemical classes in complex biological matrices, such as the whole blood or sebum collected from the skin surface. The linearity of the analytical signal response from drug concentration confirms the possibility of creating a simple semiquantitative method for small molecules monitoring using spherical sampler probes.
Collapse
|
8
|
Maciel LÍL, Rodrigues Feitosa Ramalho R, Izidoro Ribeiro R, Cunha Xavier Pinto M, Pereira I, Vaz BG. Combining the Katritzky Reaction and Paper Spray Ionization Mass Spectrometry for Enhanced Detection of Amino Acid Neurotransmitters in Mouse Brain Sections. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2513-2518. [PMID: 34464122 DOI: 10.1021/jasms.1c00153] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
This work describes the development of a system that combines a derivatization protocol based on the Katritzky reaction with paper spray ionization mass spectrometry (PSI-MS) for the analysis of amino acid neurotransmitters in mouse brain tissues. The system is relatively simple, consisting of spraying the derivatization solution onto a mouse brain section mounted on a glass slide, applying a small volume of solvent to moisten the sample, pressing a triangular paper onto the sample surface to transfer the sample constituents to the paper surface, and using the paper as a substrate for PSI-MS analysis. The Katritzky reaction facilitated the ionization of the amino acids by reacting a pyrylium salt with the amino group of the analytes, forming very stable pyridinium cations, which greatly increased the sensitivity of the PSI-MS analysis. Most of the intensities of the amino acids modified by the Katritzky reaction were more than 10 times greater than the nonderivatized ones. The system was applied for the analysis of brain sections obtained from mice with Parkinson's disease, and the amino acids gamma-aminobutyric acid (GABA) and glycine (Gly), two compounds very well-known in studies of Parkinson's disease, were readily detected. The results suggest that the Katritzky reaction combined with PSI-MS might offer a significant advance in the knowledge on protocols that improve the sensitivity of detection of crucial biological compounds.
Collapse
Affiliation(s)
| | | | - Raul Izidoro Ribeiro
- Institute of Biological Sciences, Federal University of Goiás, 74690-900, Goiânia, Brazil
| | | | - Igor Pereira
- Chemistry Institute, Federal University of Goiás, 74690-900, Goiânia, Brazil
| | - Boniek Gontijo Vaz
- Chemistry Institute, Federal University of Goiás, 74690-900, Goiânia, Brazil
| |
Collapse
|
9
|
Azizov S, Sharipov M, Lim JM, Tawfik SM, Kattaev N, Lee YI. Solvent-resistant microfluidic paper-based analytical device/spray mass spectrometry for quantitative analysis of C 18 -ceramide biomarker. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4611. [PMID: 32789982 DOI: 10.1002/jms.4611] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 06/28/2020] [Accepted: 06/30/2020] [Indexed: 06/11/2023]
Abstract
We developed a highly efficient and low-cost organic solvents-resistant microfluidic paper-based analytical device (μPAD) coupled with paper spray mass spectrometry (PS-MS) for quantitative determination of C18 -ceramide as a prognostic biomarker for several diseases. Several models of μPAD patterns have been examined to select the most resistant and efficient microchannel barriers, which can provide continuous spray at ionization zone and prevent "coffee ring" effect. Moreover, the developed μPAD has enabled the analysis of low concentration of C18 -ceramide because of the maximum supply of deposited analyte through microchannel. The MS results confirmed the formation of doubly and singly charged metal ion complexes between ceramide and different metal ions. Notably, the complexation that occurs between lithium ions and C18 -ceramide showed a high relative abundance compared with other formed complexes. Taking into account the relative abundance of complex [Cer + Li]+ at 572.8 m/z, it can be considered as a stable ion and therefore be used for the analysis of C18 -ceramide at low concentrations. Complexation of C18 -ceramide and lithium confirmed with quantum chemical calculations. The proposed method represents good linearity with a regression coefficient of 0.9956 for the analysis of C18 -ceramide and reaches a limit of detection to 0.84 nM. It has been adapted successfully for practical application in human serum samples with high recovery values in range of 92%-105%. The developed μPAD-MS technique provides clear advantages by reducing the experimental steps and simplifying the operation process and enables to identify subnanomolar concentration of C18 -ceramide in human serum samples.
Collapse
Affiliation(s)
- Shavkatjon Azizov
- Department of Chemistry, Changwon National University, Changwon, 51140, Republic of Korea
| | - Mirkomil Sharipov
- Department of Chemistry, Changwon National University, Changwon, 51140, Republic of Korea
| | - Jae-Min Lim
- Department of Chemistry, Changwon National University, Changwon, 51140, Republic of Korea
| | - Salah M Tawfik
- Department of Chemistry, Changwon National University, Changwon, 51140, Republic of Korea
| | - Nuritdin Kattaev
- Department of Chemistry, National University of Uzbekistan, Tashkent, 100174, Uzbekistan
| | - Yong-Ill Lee
- Department of Chemistry, Changwon National University, Changwon, 51140, Republic of Korea
| |
Collapse
|
10
|
Min K, Yang Q, Zhong X, Yan D, Luo W, Fang Z, Xiao J, Ma M, Chen B. Rapid analysis of anionic and cationic surfactants in water by paper spray mass spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:986-995. [PMID: 33533766 DOI: 10.1039/d0ay02215b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The discharge of wastewater containing surfactants and other industrial pollutants is contaminating the world's water resources which should be taken seriously. This paper describes a paper spray mass spectrometric (PS-MS) method for rapid and quantitative analysis of anionic and cationic surfactants in water samples. Eight cationic surfactants and four anionic surfactants can be simultaneously determined in positive or negative mode without sample pretreatment and chromatographic separation. The PS-MS analysis time was only 10 s. Under optimized conditions, the method presented a suitable linear range (1-80 μg mL-1, linear regression coefficients (R2) higher than 0.995 for cationic surfactants, R2 higher than 0.990 for anionic surfactants), a low limit of detection (0.05-0.35 μg mL-1 for cationic surfactants and 0.20-0.35 μg mL-1 for anionic surfactants), and satisfactory recovery values (97.3-106.1%). The method validation indicated that the method precision and accuracy were satisfactory. The results demonstrated that PS-MS is especially suitable for the high-throughput analysis of surfactants in water samples.
Collapse
Affiliation(s)
- Ke Min
- Key Laboratory of Phytochemical R&D of Hunan Province, Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research of Ministry of Education, Hunan Normal University, Changsha 410081, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Li X, Attanayake K, Valentine, Li P. Vibrating Sharp-edge Spray Ionization (VSSI) for voltage-free direct analysis of samples using mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35 Suppl 1:e8232. [PMID: 29993155 PMCID: PMC6529299 DOI: 10.1002/rcm.8232] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 06/28/2018] [Accepted: 07/03/2018] [Indexed: 10/14/2023]
Abstract
RATIONALE The development of miniaturized and field portable mass spectrometers could not succeed without a simple, compact, and robust ionization source. Here we present a voltage-free ionization method, Vibrating Sharp-edge Spray Ionization (VSSI), which can generate a spray of liquid samples using only one standard microscope glass slide to which a piezoelectric transducer is attached. Compared with existing ambient ionization methods, VSSI eliminates the need for a high electric field (~5000 V·cm-1 ) for spray generation, while sharing a similar level of simplicity and flexibility with the simplest direct ionization techniques currently available such as paper spray ionization (PSI) and other solid substrate-based electrospray ionization methods. METHODS The VSSI device was fabricated by attaching a piezoelectric transducer onto a standard glass microscope slide using epoxy glue. Liquid sample was aerosolized by either placing a droplet onto the vibrating edge of the glass slide or touching a wet surface with the glass edge. Mass spectrometric detection was achieved by placing the VSSI device 0.5-1 cm from the inlet of the mass spectrometer (Q-Exactive, ThermoScientific). RESULTS VSSI is demonstrated to ionize a diverse array of chemical species, including small organic molecules, carbohydrates, peptides, proteins, and nucleic acids. Preliminary sensitivity experiments show that high-quality mass spectra of acetaminophen can be obtained by consuming 100 femtomoles of the target. The dual spray of VSSI was also demonstrated by performing in-droplet denaturation of ubiquitin. Finally, due to the voltage-free nature and the direct-contact working mode of VSSI, it has been successfully applied for the detection of chemicals directly from human fingertips. CONCLUSIONS Overall, we report a compact ionization method based on vibrating sharp-edges. The simplicity and voltage-free nature of VSSI make it an attractive option for field portable applications or analyzing biological samples that are sensitive to high voltage or difficult to access by conventional ionization methods.
Collapse
Affiliation(s)
- Xiaojun Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Kushani Attanayake
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
12
|
Abstract
Direct ambient ionization techniques have been developed with the aim to reduce the complexity of mass spectrometry analysis by minimizing sample preparation and chromatographic separation. In this context, paper spray-MS (PS-MS) is an innovative approach that provides faster and cheaper analysis of biofluids by the addition of the sample directly to a paper. In forensic toxicology, the analytical workflow for the detection and quantification of drugs of abuse is onerous, including sample treatment, extraction and clean up, especially regarding complex biological matrices. PS-MS allows the detection of analytes of toxicological interest in blood, plasma and urine using low sample volume. This review aims to discuss the potential use, advances and challenges of PS-MS in forensic toxicology.
Collapse
|
13
|
Mendes TPP, Pereira I, de Lima LAS, Morais CLM, Neves ACON, Martin FL, Lima KMG, Vaz BG. Paper Spray Ionization Mass Spectrometry as a Potential Tool for Early Diagnosis of Cervical Cancer. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1665-1672. [PMID: 32614181 DOI: 10.1021/jasms.0c00111] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Squamous intraepithelial lesion is an abnormal growth of epithelial cells on the surface of the cervix that may lead to cervical cancer. Analytical protocols for the determination of squamous intraepithelial lesions are in high demand, since cervical cancer is the fourth most diagnosed cancer among women in the world. Here, paper spray ionization mass spectrometry (PSI-MS) is used to distinguish between healthy (negative for intraepithelial lesion or malignancy) and diseased (high-grade squamous intraepithelial lesion) blood plasmas. A total of 86 blood samples of different women (49 healthy samples, 37 diseased samples) were collected, and the plasmas were prepared. Then, 10 μL of each plasma sample was deposited onto triangular papers for PSI-MS analysis. No additional step of sample preparation was necessary. The interval-successive projection algorithm linear discriminant analysis (iSPA-LDA) was applied to the PSI mass spectra, showing six ions (mostly phospholipids) that were predictive of healthy and diseased plasmas. Values of 77% accuracy, 86% sensitivity, 80% positive predictive value (PPV), and 75% negative predictive value (NPV) were achieved. This study provides evidence that PSI-MS may potentially be used as a fast and simple analytical technique for the early diagnosis of cervical cancer.
Collapse
Affiliation(s)
- Thais P P Mendes
- Chemistry Institute, Federal University of Goiás, Goiánia, Brazil
| | - Igor Pereira
- Chemistry Institute, Federal University of Goiás, Goiánia, Brazil
| | | | - Camilo L M Morais
- School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, United Kingdom
| | - Ana C O N Neves
- Chemistry Institute, Federal University of Rio Grande do Norte, Natal, Brazil
| | | | - Kássio M G Lima
- Chemistry Institute, Federal University of Rio Grande do Norte, Natal, Brazil
| | | |
Collapse
|
14
|
Díaz-Liñán MC, García-Valverde MT, Lucena R, Cárdenas S, López-Lorente AI. Paper-based sorptive phases for microextraction and sensing. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3074-3091. [PMID: 32930167 DOI: 10.1039/d0ay00702a] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The simplification of the analytical procedures, including cost-effective materials and detectors, is a current research trend. In this context, paper has been identified as a useful material thanks to its low price and high availability in different compositions (office, filter, chromatographic). Its porosity, flexibility, and planar geometry permit the design of flow-through devices compatible with most instrumental techniques. This article provides a general overview of the potential of paper, as substrate, on the simplification of analytical chemistry methodologies. The design of paper-based sorptive phases is considered in-depth, and the different functionalization strategies are described. Considering our experience in sample preparation, special attention has been paid to the use of these phases under the classical microextraction-analysis workflow, which usually includes a chromatographic separation of the analytes before their determination. However, the interest of these materials extends beyond this field as they can be easily implemented into spectroscopic and electrochemical sensors. Finally, the direct analysis of paper substrates in mass spectrometry, in the so-called paper-spray technique is also discussed. This review is more focused on presenting ideas rather than the description of specific applications to draw a general picture of the potential of these materials.
Collapse
Affiliation(s)
- M C Díaz-Liñán
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - M T García-Valverde
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - R Lucena
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - S Cárdenas
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - A I López-Lorente
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| |
Collapse
|
15
|
Yao YN, Di D, Yuan ZC, Wu L, Hu B. Schirmer Paper Noninvasive Microsampling for Direct Mass Spectrometry Analysis of Human Tears. Anal Chem 2020; 92:6207-6212. [PMID: 32250596 DOI: 10.1021/acs.analchem.9b05078] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Rapid and sensitive detection of metabolites and chemical residues in human tears is highly beneficial for understanding eye health. In this study, Schirmer paper was used for noninvasive microsampling of human tears, and then paper spray mass spectrometry (PSMS) was performed for direct analysis of human tears. Schirmer PSMS was successfully used for rapid diagnosis of dry-eye syndrome by detecting the volume and metabolites of human tears. Drugs of abuse, therapeutic drugs, and pharmacodynamics in human tears were also investigated by Schirmer PSMS. Furthermore, specific markers of environmental exposures in the air to human eyes, including volatile organic compounds, aerosol, and smoke, were unambiguously sampled and detected in human tears using Schirmer PSMS. Excellent analytical performances were achieved, including single-use, low-sample consumption (1.0 μL), rapid analysis (the whole analytical procedure completed within 3 min), high sensitivity (absolute limit of detection less than or equal to 0.5 pg, signal-to-noise ratio greater than or equal to 3), good reproducibility (relative standard deviation less than 10%, n = 3), and accurate quantitation (average deviation less than 3%, n = 3). Overall, our results showed that Schirmer PSMS is a highly effective method for direct tear analysis and is expected to be a convenient tool for human tear analysis in significant clinical applications.
Collapse
Affiliation(s)
- Ya-Nan Yao
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Dandan Di
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Zi-Cheng Yuan
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Lin Wu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| |
Collapse
|
16
|
Narayanan R, Song X, Chen H, Zare RN. Teflon Spray Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:234-239. [PMID: 31939677 DOI: 10.1021/jasms.9b00069] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Polytetrafluoroethene, commonly known as Teflon, is a plastic famous for its inertness, strength, and nonstick properties, allowing its repeated use in many applications. We report the use of a triangularly cut Teflon substrate to take the place of paper in a form of spray mass spectrometry. A conducting wire (gold) at high potential (positive or negative) makes contact with a drop of the liquid sample at the apex of the triangle, causing a spray of droplets to be directed toward the heated inlet of a mass spectrometer. Saccharides, drugs, illegal additives, peptides, proteins, bilirubin, and vancomycin give mass spectra with high signal-to-noise (S/N) ratios, allowing detection at the nanogram per milliliter (ng/mL) level. Examination of each of these analytes demonstrates that Teflon spray is several orders of magnitude more sensitive than paper spray under the same conditions. Teflon spray ionization mass spectrometry is applied to the metabolomic and lipidomic profiling of biological fluid samples. Detection of polycyclic aromatic hydrocarbons is achieved with Teflon spray at 10 μg/mL concentrations. These experiments show the advantage of using Teflon over a normal paper substrate in detecting many environmentally and biologically relevant systems with high sensitivity and S/N ratio.
Collapse
Affiliation(s)
- Rahul Narayanan
- Department of Chemistry , Fudan University , Shanghai 200438 , China
| | - Xiaowei Song
- Department of Chemistry , Fudan University , Shanghai 200438 , China
| | - Hao Chen
- Department of Chemistry & Environmental Science , New Jersey Institute of Technology , Newark , New Jersey 07102 , United States
| | - Richard N Zare
- Department of Chemistry , Fudan University , Shanghai 200438 , China
| |
Collapse
|
17
|
Huang YC, Chung HH, Dutkiewicz EP, Chen CL, Hsieh HY, Chen BR, Wang MY, Hsu CC. Predicting Breast Cancer by Paper Spray Ion Mobility Spectrometry Mass Spectrometry and Machine Learning. Anal Chem 2019; 92:1653-1657. [DOI: 10.1021/acs.analchem.9b03966] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Ying-Chen Huang
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Hsin-Hsiang Chung
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | | | - Chih-Lin Chen
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Hua-Yi Hsieh
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Bo-Rong Chen
- Department of Surgery, National Taiwan University Hospital, Taipei 10002, Taiwan
| | - Ming-Yang Wang
- Department of Surgery, National Taiwan University Hospital, Taipei 10002, Taiwan
| | - Cheng-Chih Hsu
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| |
Collapse
|
18
|
Wichert WRA, Dhummakupt ES, Zhang C, Mach PM, Bernhards RC, Glaros T, Manicke NE. Detection of Protein Toxin Simulants from Contaminated Surfaces by Paper Spray Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1406-1415. [PMID: 30859394 DOI: 10.1007/s13361-019-02141-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 01/17/2019] [Accepted: 01/18/2019] [Indexed: 06/09/2023]
Abstract
Proteinaceous toxins are harmful proteins derived from plants, bacteria, and other natural sources. They pose a risk to human health due to infection and also as possible biological warfare agents. Paper spray mass spectrometry (PS-MS) with wipe sampling was used to detect proteins from surfaces as a potential tool for identifying the presence of these toxins. Proteins ranging in mass between 12.4 and 66.5 kDa were tested, including a biological toxin simulant/vaccine for Staphylococcal enterotoxin B (SEBv). Various substrates were tested for these representative proteins, including a laboratory bench, a notebook cover, steel, glass, plant leaf and vinyl flooring. Carbon sputtered porous polyethylene (CSPP) was found to outperform typical chromatography paper used for paper spray, as well as carbon nanotube (CNT)-coated paper and polyethylene (PE), which have been previously shown to be well-suited for protein analysis. Low microgram quantities of the protein toxin simulant and other test proteins were successfully detected with good signal-to-noise from surfaces using a porous wipe. These applications demonstrate that PS-MS can potentially be used for rapid, sample preparation-free detection of proteins and biological warfare agents, which would be beneficial to first responders and warfighters.
Collapse
Affiliation(s)
- William R A Wichert
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, 402 N. Blackford St., Indianapolis, IN, 46202, USA
| | - Elizabeth S Dhummakupt
- Combat Capabilities Development Command (CCDC) Chemical Biological Center, U.S. Army, 5183 Blackhawk Rd., Aberdeen Proving Ground, MD, 21010-5424, USA
| | - Chengsen Zhang
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, 402 N. Blackford St., Indianapolis, IN, 46202, USA
| | - Phillip M Mach
- Combat Capabilities Development Command (CCDC) Chemical Biological Center, U.S. Army, 5183 Blackhawk Rd., Aberdeen Proving Ground, MD, 21010-5424, USA
| | - Robert C Bernhards
- Combat Capabilities Development Command (CCDC) Chemical Biological Center, U.S. Army, 5183 Blackhawk Rd., Aberdeen Proving Ground, MD, 21010-5424, USA
- Defense Threat Reduction Agency, Fort Belvoir, VA, 22060, USA
| | - Trevor Glaros
- Combat Capabilities Development Command (CCDC) Chemical Biological Center, U.S. Army, 5183 Blackhawk Rd., Aberdeen Proving Ground, MD, 21010-5424, USA.
| | - Nicholas E Manicke
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, 402 N. Blackford St., Indianapolis, IN, 46202, USA.
| |
Collapse
|
19
|
Riboni N, Quaranta A, Motwani HV, Österlund N, Gräslund A, Bianchi F, Ilag LL. Solvent-Assisted Paper Spray Ionization Mass Spectrometry (SAPSI-MS) for the Analysis of Biomolecules and Biofluids. Sci Rep 2019; 9:10296. [PMID: 31311939 PMCID: PMC6635430 DOI: 10.1038/s41598-019-45358-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Accepted: 05/24/2019] [Indexed: 12/23/2022] Open
Abstract
Paper Spray Ionization (PSI) is commonly applied for the analysis of small molecules, including drugs, metabolites, and pesticides in biological fluids, due to its high versatility, simplicity, and low costs. In this study, a new setup called Solvent Assisted Paper Spray Ionization (SAPSI), able to increase data acquisition time, signal stability, and repeatability, is proposed to overcome common PSI drawbacks. The setup relies on an integrated solution to provide ionization potential and constant solvent flow to the paper tip. Specifically, the ion source was connected to the instrument fluidics along with the voltage supply systems, ensuring a close control over the ionization conditions. SAPSI was successfully applied for the analysis of different classes of biomolecules: amyloidogenic peptides, proteins, and N-glycans. The prolonged analysis time allowed real-time monitoring of processes taking places on the paper tip, such as amyloid peptides aggregation and disaggregation phenomena. The enhanced signal stability allowed to discriminate protein species characterized by different post translational modifications and adducts with electrophilic compounds, both in aqueous solutions and in biofluids, such as serum and cerebrospinal fluid, without any sample pretreatment. In the next future, application to clinical relevant modifications, could lead to the development of quick and cost-effective diagnostic tools.
Collapse
Affiliation(s)
- Nicoló Riboni
- Department of Environmental Science and Analytical Chemistry, Stockholm University, Stockholm, SE, Sweden.,Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parma, IT, Italy
| | - Alessandro Quaranta
- Department of Environmental Science and Analytical Chemistry, Stockholm University, Stockholm, SE, Sweden
| | - Hitesh V Motwani
- Department of Environmental Science and Analytical Chemistry, Stockholm University, Stockholm, SE, Sweden
| | - Nicklas Österlund
- Department of Biochemistry and Biophysics, Stockholm University, Stockholm, SE, Sweden
| | - Astrid Gräslund
- Department of Biochemistry and Biophysics, Stockholm University, Stockholm, SE, Sweden
| | - Federica Bianchi
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parma, IT, Italy
| | - Leopold L Ilag
- Department of Environmental Science and Analytical Chemistry, Stockholm University, Stockholm, SE, Sweden.
| |
Collapse
|
20
|
New Mass Spectrometric Approaches for the Quantitative Evaluation of Anticancer Drug Levels in Treated Patients. Ther Drug Monit 2019; 41:1-10. [PMID: 30422961 DOI: 10.1097/ftd.0000000000000573] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Alternatively to the well-consolidated liquid chromatography coupled to tandem mass spectrometry approach used for the evaluation of anticancer drug concentrations in treated patients, new mass spectrometric methods have been proposed and tested recently. They exhibited faster analysis time and, at first sight, simpler instrumental approaches. However, results obtained by these methods require an in-depth evaluation, because of their strong dependence on the experimental set-up. In this short review, the quantification of irinotecan, sunitinib, and 6-α-hydroxy paclitaxel (the main metabolite of paclitaxel) by laser desorption ionization techniques (matrix-assisted laser desorption/ionization, nanostructure-assisted laser desorption/ionization, and surface-assisted laser desorption/ionization) is reported and discussed, showing the advantages but also the drawbacks of the methods. The matrix-assisted laser desorption/ionization approach led to the most reliable results, and the cross-validation for the quantitative analysis of irinotecan indicates that this method can be fruitfully used for therapeutic drug monitoring and pharmacokinetic studies. Another recently proposed technique, paper spray mass spectrometry, has been tested for the quantitative measurement of imatinib in plasma samples. Even if the approach is, at first sight, really simple, the parameterization of the analytical and instrumental aspects has required many efforts to reach satisfactory results. What it should be expected in the future is the evaluation of these methods, not only in scientific environments dedicated to instrument development, but also in clinical chemistry laboratories, to evaluate their effectiveness and to give new and valid tools for TDM and for other qualitative or quantitative measurements of biomedical interest.
Collapse
|
21
|
Looby NT, Tascon M, Acquaro VR, Reyes-Garcés N, Vasiljevic T, Gomez-Rios GA, Wąsowicz M, Pawliszyn J. Solid phase microextraction coupled to mass spectrometry via a microfluidic open interface for rapid therapeutic drug monitoring. Analyst 2019; 144:3721-3728. [PMID: 30968079 DOI: 10.1039/c9an00041k] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Tranexamic acid (TXA) is an antifibrinolytic used during cardiac surgery that presents high inter-patient variability.
Collapse
Affiliation(s)
- Nikita T. Looby
- Department of Chemistry
- University of Waterloo
- 200 University Avenue west
- Waterloo
- Canada
| | - Marcos Tascon
- Department of Chemistry
- University of Waterloo
- 200 University Avenue west
- Waterloo
- Canada
| | - Vinicius R. Acquaro
- Department of Chemistry
- University of Waterloo
- 200 University Avenue west
- Waterloo
- Canada
| | - Nathaly Reyes-Garcés
- Department of Chemistry
- University of Waterloo
- 200 University Avenue west
- Waterloo
- Canada
| | - Tijana Vasiljevic
- Department of Chemistry
- University of Waterloo
- 200 University Avenue west
- Waterloo
- Canada
| | | | - Marcin Wąsowicz
- Department of Anaesthesia and Pain Management
- Toronto General Hospital
- Toronto
- Canada M5G 2C4
| | - Janusz Pawliszyn
- Department of Chemistry
- University of Waterloo
- 200 University Avenue west
- Waterloo
- Canada
| |
Collapse
|
22
|
Development of paper substrate for paper spray MS in high-sensitivity analysis of biological samples. Bioanalysis 2018; 10:2047-2067. [DOI: 10.4155/bio-2018-0199] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Paper spray (PS) has demonstrated a promising future for direct mass spectrometric analysis. In the process of PS, paper substrate has been demonstrated as a crucial factor in determining the final performance of PS-MS, and therefore much attention is paid to modification of paper substrate. In this review, we systematically introduce the development of paper substrate for PS. Various commercial and modified papers are comprehensively reviewed, and much effort is focused on some physical and chemical approaches for modification of paper substrate. The application of modified paper substrates to biological sample analyses is discussed. The future promising directions of paper substrate for PS are highlighted.
Collapse
|
23
|
Liu Y, Zhou Y, Dai Y, Zhao Z, He L, Zhang Q. Quantitative analysis of finasteride tablets dissolution content with non-isotopically labeled internal standard by paper spray ionization mass spectrometry. J Sep Sci 2018; 41:4083-4089. [PMID: 30182471 DOI: 10.1002/jssc.201800606] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 08/06/2018] [Accepted: 08/28/2018] [Indexed: 12/29/2022]
Abstract
Paper spray ionization, one of the ambient mass spectrometry technologies, has been developed to characterize the content of drugs in various complex matrixes including urine, whole blood, dissolution solutions, and so on. An isotopically labeled compound as internal standard is often used in quantitative paper spray ionization experiments. But high cost and difficult to access impede the application of this type of internal standards. Application of non-isotopically labeled compounds as internal standards will make this technology more prevalent. In this paper, we explored the application of finasteride impurity as the internal standard in paper spray ionization-mass spectrometry to measure the dissolution content of finasteride tablets. The new method was optimized and the results were compared to those from high-performance liquid chromatography. The whole analysis time was several minutes and limit of detection for finasteride was around 4.8 ng/mL. The results from paper spray ionization-mass spectrometry were similar to those from high-performance liquid chromatography. Combination of paper spray ionization-mass spectrometry and non-isotopically labeled internal standard renders a new method to analyze drug dissolution content with high specificity, low limit of detection, and simple sample preparation within short time period.
Collapse
Affiliation(s)
- Yang Liu
- National Institutes for Food and Drug Control, Beijing, P. R. China
| | - Yanan Zhou
- National Institutes for Food and Drug Control, Beijing, P. R. China
| | - Yandong Dai
- National Institutes for Food and Drug Control, Beijing, P. R. China
| | - Zhuang Zhao
- Guangxi Institute for Food and Drug Control, Nanning, P. R. China
| | - Lan He
- National Institutes for Food and Drug Control, Beijing, P. R. China
| | - Qingsheng Zhang
- National Institutes for Food and Drug Control, Beijing, P. R. China
| |
Collapse
|
24
|
Chiang S, Zhang W, Ouyang Z. Paper spray ionization mass spectrometry: recent advances and clinical applications. Expert Rev Proteomics 2018; 15:781-789. [PMID: 30223684 PMCID: PMC6320440 DOI: 10.1080/14789450.2018.1525295] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Paper spray mass spectrometry has provided a rapid, quantitative ambient ionization method for xenobiotic and biomolecule analysis. As an alternative to traditional sample preparation and chromatography, paper spray demonstrates the sampling ionization of a wide range of molecules and significant sensitivity from complex biofluids. The amenability of paper spray with dried blood spots and other sampling types shows strong potential for rapid, point-of-care (POC) analysis without time-consuming separation procedures. Areas covered: This special report summarizes the current state and advances in paper spray mass spectrometry that relate to its applicability for clinical analysis. It also provides our perspectives on the future development of paper spray mass spectrometry and its potential roles in clinical settings. Expert commentary: Paper spray has provided the fundamental aspects of ambient ionization needed for implementation at the POC. With further clinical management and standardization, paper spray has the potential to replace traditional complex analysis procedure for rapid quantitative detection of illicit drugs, therapeutic drugs and metabolites. Surface and substrate modifications also offer significant improvement in desorption and ionization efficiencies, resulting in enhanced sensitivity. Comprehensive analysis of metabolites and lipids will further extend the implementation of paper spray ionization mass spectrometry into clinical applications.
Collapse
Affiliation(s)
- Spencer Chiang
- State Key Laboratory of Precision Measurement Technology
and Instruments, Department of Precision Instrument, Tsinghua University, Beijing,
China
- Weldon School of Biomedical Engineering, Purdue University,
West Lafayette, Indiana, USA
| | - Wenpeng Zhang
- State Key Laboratory of Precision Measurement Technology
and Instruments, Department of Precision Instrument, Tsinghua University, Beijing,
China
- Weldon School of Biomedical Engineering, Purdue University,
West Lafayette, Indiana, USA
| | - Zheng Ouyang
- State Key Laboratory of Precision Measurement Technology
and Instruments, Department of Precision Instrument, Tsinghua University, Beijing,
China
- Weldon School of Biomedical Engineering, Purdue University,
West Lafayette, Indiana, USA
| |
Collapse
|
25
|
Bianchi F, Riboni N, Termopoli V, Mendez L, Medina I, Ilag L, Cappiello A, Careri M. MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2018; 2018:1308167. [PMID: 29850370 PMCID: PMC5937452 DOI: 10.1155/2018/1308167] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 02/26/2018] [Indexed: 05/15/2023]
Abstract
Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.
Collapse
Affiliation(s)
- Federica Bianchi
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| | - Nicolò Riboni
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
- Department of Environmental Science and Analytical Chemistry, Stockholm University, 10691 Stockholm, Sweden
| | - Veronica Termopoli
- Department of Pure and Applied Sciences, LC-MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Lucia Mendez
- Instituto de Investigaciones Marinas, Spanish National Research Council (IIM-CSIC), Eduardo Cabello 6, 36208 Vigo, Spain
| | - Isabel Medina
- Instituto de Investigaciones Marinas, Spanish National Research Council (IIM-CSIC), Eduardo Cabello 6, 36208 Vigo, Spain
| | - Leopold Ilag
- Department of Environmental Science and Analytical Chemistry, Stockholm University, 10691 Stockholm, Sweden
| | - Achille Cappiello
- Department of Pure and Applied Sciences, LC-MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Maria Careri
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| |
Collapse
|
26
|
Yang BC, Wan XD, Yang X, Li YJ, Zhang ZY, Wan XJ, Luo Y, Deng W, Wang F, Huang OP. Rapid determination of carbendazim in complex matrices by electrospray ionization mass spectrometry with syringe filter needle. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:234-239. [PMID: 29314422 DOI: 10.1002/jms.4057] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Revised: 11/23/2017] [Accepted: 12/18/2017] [Indexed: 06/07/2023]
Abstract
The determination of pesticide residues is an indispensable task in controlling food safety and environment protection. Carbendazim is one of the extensive uses of pesticides in the agricultural industry. In this study, a simple method utilizing syringe filter has been applied as electrospray ionization emitter for mass spectrometric identification and quantification of carbendazim in complex matrices including soil, natural water, and fruit juice samples, which contain many insoluble materials. With online syringe filter of the complex samples, most of insoluble materials such as soil were excluded in spray ionization process due to the filter effect, and analytes were subsequently sprayed out from syringe needle for mass spectrometric detection. The pore sizes of filters and diameters of syringe needles also were investigated. The analytical performances, including the linear range (1-200 ng·mL-1 ), limit of detection (0.2-0.6 ng·mL-1 , S/N > 3), limit of quantitation (3.5-8.6 ng·mL-1 , S/N > 10), reproducibility (6.4%-12.5%, n = 6), and recoveries (72.1%-91.0%, n = 6) were well acceptable for direct analysis of raw samples. Matrix effect for detection of carbendazim in soil samples also was experimentally investigated. This study demonstrated that syringe filter needle coupled with electrospray ionization mass spectrometry is a simple, efficient, and sensitive method for detection of pesticide residues in water, soil, and fruit juice for risk assessment.
Collapse
Affiliation(s)
- Bi-Cheng Yang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Xi-di Wan
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Xiao Yang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Yun-Jun Li
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Zi-Yu Zhang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Xiao-Ju Wan
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Yong Luo
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Wei Deng
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Feng Wang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Ou-Ping Huang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| |
Collapse
|
27
|
Cody RB, Tamura J, Downard KM. Quantitation of anthocyanins in elderberry fruit extracts and nutraceutical formulations with paper spray ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:58-64. [PMID: 28960779 DOI: 10.1002/jms.4033] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 09/17/2017] [Accepted: 09/19/2017] [Indexed: 06/07/2023]
Abstract
The ability to rapidly identify and quantitate, over a wide range of concentrations, anthocyanins in food and therapeutic products is important to ensuring their presence at medicinally significant levels. Sensitive, yet mild, analysis conditions are required given their susceptibility to degradation and transformation. Paper spray ionization has been used to detect and quantify the levels of anthocyanin levels in extracts of fresh and dried elderberries, and elderberry stems, as well as 3 commercially available nutraceutical formulations. The component cyanidin glucosides, including cyanidin-3-sambubioside, cyanidin-3-glucoside, cyanidin-3,5-diglucoside, cyanidin-3-sambubioside-5-glucoside, and the aglycone cyanidin, were readily detected in a range of sources. Quantitation was achieved by establishing a calibration plot from dilutions of a stock solution of cyanidin-3,5-diglucoside containing malvidin-3,5-diglucoside as an internal standard at a fixed concentration. The same standard was used to quantify the anthocyanin content in the fruit and nutraceutical formulations. Wide 5-fold variations in anthocyanin concentration were detected in the nutraceutical formulations from different suppliers ranging from 1050 to 5430 mg/100 g. These concentrations compared with 500 to 2370 mg/100 g measured in the dried stems and fruit, respectively.
Collapse
|
28
|
Jacobs MI, Davies JF, Lee L, Davis RD, Houle F, Wilson KR. Exploring Chemistry in Microcompartments Using Guided Droplet Collisions in a Branched Quadrupole Trap Coupled to a Single Droplet, Paper Spray Mass Spectrometer. Anal Chem 2017; 89:12511-12519. [PMID: 29048875 DOI: 10.1021/acs.analchem.7b03704] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Recent studies suggest that reactions in aqueous microcompartments can occur at significantly different rates than those in the bulk. Most studies have used electrospray to generate a polydisperse source of highly charged microdroplets, leading to multiple confounding factors potentially influencing reaction rates (e.g., evaporation, charge, and size). Thus, the underlying mechanism for the observed enhancement remains unclear. We present a new type of electrodynamic balance-the branched quadrupole trap (BQT)-which can be used to study reactions in microdroplets in a controlled environment. The BQT allows for condensed phase chemical reactions to be initiated by colliding droplets with different reactants and levitating the merged droplet indefinitely. The performance of the BQT is characterized in several ways. Sub-millisecond mixing times as fast as ∼400 μs are measured for low velocity (∼0.1 m/s) collisions of droplets with <40 μm diameters. The reaction of o-phthalaldehyde (OPA) with alanine in the presence of dithiolthreitol is measured using both fluorescence spectroscopy and single droplet paper spray mass spectrometry. The bimolecular rate constant for reaction of alanine with OPA is found to be 84 ± 10 and 67 ± 6 M-1 s-1 in a 30 μm radius droplet and bulk solution, respectively, which demonstrates that bimolecular reaction rate coefficients can be quantified using merged microdroplets and that merged droplets can be used to study rate enhancements due to compartmentalization. Products of the reaction of OPA with alanine are detected in single droplets using paper spray mass spectrometry. We demonstrate that single droplets with <100 pg of analyte can easily be studied using single droplet mass spectrometry.
Collapse
Affiliation(s)
- Michael I Jacobs
- Department of Chemistry, University of California , Berkeley, California 94720, United States.,Chemical Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - James F Davies
- Chemical Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - Lance Lee
- Chemical Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - Ryan D Davis
- Chemical Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - Frances Houle
- Chemical Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - Kevin R Wilson
- Chemical Sciences Division, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| |
Collapse
|
29
|
Michely JA, Meyer MR, Maurer HH. Paper Spray Ionization Coupled to High Resolution Tandem Mass Spectrometry for Comprehensive Urine Drug Testing in Comparison to Liquid Chromatography-Coupled Techniques after Urine Precipitation or Dried Urine Spot Workup. Anal Chem 2017; 89:11779-11786. [DOI: 10.1021/acs.analchem.7b03398] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Affiliation(s)
- Julian A. Michely
- Department of Experimental and Clinical
Toxicology, Institute of Experimental and Clinical Pharmacology and
Toxicology, Saarland University, Homburg, Saar D-66421, Germany
| | - Markus R. Meyer
- Department of Experimental and Clinical
Toxicology, Institute of Experimental and Clinical Pharmacology and
Toxicology, Saarland University, Homburg, Saar D-66421, Germany
| | - Hans H. Maurer
- Department of Experimental and Clinical
Toxicology, Institute of Experimental and Clinical Pharmacology and
Toxicology, Saarland University, Homburg, Saar D-66421, Germany
| |
Collapse
|
30
|
Liu J, Deng W, Yu M, Wen R, Yao S, Chen B. Rapid analysis of benzalkonium chloride using paper spray mass spectrometry. J Pharm Biomed Anal 2017; 145:151-157. [DOI: 10.1016/j.jpba.2017.06.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 06/15/2017] [Accepted: 06/15/2017] [Indexed: 10/19/2022]
|
31
|
Abstract
Since the introduction of desorption electrospray ionization (DESI) mass spectrometry (MS), ambient MS methods have seen increased use in a variety of fields from health to food science. Increasing its popularity in metabolomics, ambient MS offers limited sample preparation, rapid and direct analysis of liquids, solids, and gases, in situ and in vivo analysis, and imaging. The metabolome consists of a constantly changing collection of small (<1.5 kDa) molecules. These include endogenous molecules that are part of primary metabolism pathways, secondary metabolites with specific functions such as signaling, chemicals incorporated in the diet or resulting from environmental exposures, and metabolites associated with the microbiome. Characterization of the responsive changes of this molecule cohort is the principal goal of any metabolomics study. With adjustments to experimental parameters, metabolites with a range of chemical and physical properties can be selectively desorbed and ionized and subsequently analyzed with increased speed and sensitivity. This review covers the broad applications of a variety of ambient MS techniques in four primary fields in which metabolomics is commonly employed.
Collapse
Affiliation(s)
- Chaevien S. Clendinen
- School of Chemistry and Biochemistry & Petit Institute for Bioengineering & Bioscience (IBB), Georgia Institute of Technology, 901 Atlantic Drive NW. Atlanta, GA
| | - María Eugenia Monge
- Centro de Investigaciones en Bionanociencias (CIBION), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2390, C1425FQD, Ciudad de Buenos Aires, Argentina
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry & Petit Institute for Bioengineering & Bioscience (IBB), Georgia Institute of Technology, 901 Atlantic Drive NW. Atlanta, GA
| |
Collapse
|
32
|
Guo Y, Gu Z, Liu X, Liu J, Ma M, Chen B, Wang L. Rapid Analysis of Corni fructus Using Paper Spray-Mass Spectrometry. PHYTOCHEMICAL ANALYSIS : PCA 2017; 28:344-350. [PMID: 28239915 DOI: 10.1002/pca.2681] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Revised: 01/18/2017] [Accepted: 01/27/2017] [Indexed: 06/06/2023]
Abstract
INTRODUCTION Paper spray-mass spectrometry (PS-MS) is a kind of ambient MS technique for the rapid analysis of samples. Corni fructus has been widely used in traditional Chinese compound preparations and healthy food. However, a number of counterfeits of Corni fructus, such as Crataegi fructus, Lycii fructus, and grape skin are illegally sold in crude herb markets. Therefore, the development of a rapid and high-throughput quality evaluation method is important for ensuring the effectiveness and safety of the crude materials of Corni fructus. OBJECTIVE To develop PS-MS chemical profiles and a semi-quantitative method of Corni fructus for quality assessment and control, and species distinction of Corni fructus. METHODOLOGY Both positive and negative ion PS-MS chemical profiles were constructed for species distinction. The statistical analysis of the chemical profiles was accomplished by principal component analysis (PCA). Rapid semi-quantitative analysis of loganin and morroniside in the extracts of Corni fructus were accomplished by PS-MS. RESULTS The profiles of the Corni fructus and Crataegi fructus samples were clearly clustered into two categories. The limit of quantification (LOQ) in the semi-quantitative analysis was 6 μg/mL and 5.6 μg/mL for loganin and morroniside, respectively. CONCLUSION PS-MS is a simple, rapid, and high-throughput method for the quality control and species distinction of Corni fructus. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Yuan Guo
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha, 410081, P. R. China
| | - Zhixin Gu
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha, 410081, P. R. China
| | - Xuemei Liu
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha, 410081, P. R. China
| | - Jingjing Liu
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha, 410081, P. R. China
| | - Ming Ma
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha, 410081, P. R. China
| | - Bo Chen
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha, 410081, P. R. China
| | - Liping Wang
- Hunan Analysis and Testing Centre, Changsha, 410004, P. R. China
| |
Collapse
|
33
|
Chen S, Chang Q, Yin K, He Q, Deng Y, Chen B, Liu C, Wang Y, Wang L. Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2017; 65:4859-4865. [PMID: 28535678 DOI: 10.1021/acs.jafc.7b02061] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this study, a paper spray ionization mass spectrometric (PS-MS) method was developed for the rapid in situ screening and simultaneous quantitative analysis of bisphenol A and its analogues, i.e., bisphenol S, bisphenol F, and bisphenol AF, in food packaging products. At the optimal PS-MS conditions, the calibration curves of bisphenols in the range of 1-100 μg/mL were linear. The correlation coefficients were higher than 0.998, and the LODs of the target compounds were 0.1-0.3 μg/mL. After a simple treatment by dichloromethane on the surface, the samples were analyzed by PS-MS in situ for rapid screening without a traditional sample pretreatment procedure, such as powdering, extraction, and enrichment steps. The analytical time of the PS-MS method was less than 1 min. In comparison with conventional HPLC-MS/MS, it was demonstrated that PS-MS was a more effective high-throughput screening and quantitative analysis method.
Collapse
Affiliation(s)
- Shuo Chen
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University , Changsha 410082, China
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University , Changsha 410081, China
| | - Quanying Chang
- College of Finance and Statistics, Hunan University , Changsha 410082, China
| | - Kai Yin
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University , Changsha 410082, China
| | - Qunying He
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University , Changsha 410082, China
| | - Yongxiu Deng
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University , Changsha 410082, China
| | - Bo Chen
- Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University , Changsha 410081, China
| | - Chengbin Liu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University , Changsha 410082, China
| | - Ying Wang
- College of Finance and Statistics, Hunan University , Changsha 410082, China
| | - Liping Wang
- Hunan Analysis and Testing Center , Changsha 410004, China
| |
Collapse
|
34
|
New urea-modified paper substrate for enhanced analytical performance of negative ion mode paper spray mass spectrometry. Talanta 2017; 166:306-314. [DOI: 10.1016/j.talanta.2017.01.076] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 01/19/2017] [Accepted: 01/26/2017] [Indexed: 12/20/2022]
|
35
|
Rapid analysis of Aurantii Fructus Immaturus (Zhishi) using paper spray ionization mass spectrometry. J Pharm Biomed Anal 2017; 137:204-212. [DOI: 10.1016/j.jpba.2017.01.034] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 01/14/2017] [Accepted: 01/16/2017] [Indexed: 12/16/2022]
|
36
|
Meher AK, Chen YC. Electrospray Modifications for Advancing Mass Spectrometric Analysis. ACTA ACUST UNITED AC 2017; 6:S0057. [PMID: 28573082 DOI: 10.5702/massspectrometry.s0057] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 12/30/2016] [Indexed: 11/23/2022]
Abstract
Generation of analyte ions in gas phase is a primary requirement for mass spectrometric analysis. One of the ionization techniques that can be used to generate gas phase ions is electrospray ionization (ESI). ESI is a soft ionization method that can be used to analyze analytes ranging from small organics to large biomolecules. Numerous ionization techniques derived from ESI have been reported in the past two decades. These ion sources are aimed to achieve simplicity and ease of operation. Many of these ionization methods allow the flexibility for elimination or minimization of sample preparation steps prior to mass spectrometric analysis. Such ion sources have opened up new possibilities for taking scientific challenges, which might be limited by the conventional ESI technique. Thus, the number of ESI variants continues to increase. This review provides an overview of ionization techniques based on the use of electrospray reported in recent years. Also, a brief discussion on the instrumentation, underlying processes, and selected applications is also presented.
Collapse
Affiliation(s)
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University
| |
Collapse
|
37
|
Liu Y, Liu N, Zhou YN, Lin L, He L. Rapid analysis of drug dissolution by paper spray ionization mass spectrometry. J Pharm Biomed Anal 2017; 136:106-110. [DOI: 10.1016/j.jpba.2016.12.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Revised: 12/19/2016] [Accepted: 12/20/2016] [Indexed: 01/14/2023]
|
38
|
Liu JY, Chen PC, Liou YW, Chang KY, Lin CH. Development and Application of a Brush-Spray Derived from a Calligraphy-Brush-Style Synthetic Hair Pen for Use in ESI/MS. Mass Spectrom (Tokyo) 2017; 6:S0058. [PMID: 28337397 PMCID: PMC5358408 DOI: 10.5702/massspectrometry.s0058] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 12/30/2016] [Indexed: 11/23/2022] Open
Abstract
The development of a novel type of a sampling/ionization kit for use in electrospray ionization/mass spectrometry is reported. Using a small calligraphy-brush-style synthetic hair pen (nylon-brush), and analogous to paper-spray mass spectrometry, the analytes can be collected, elution/desorption and then ionized from the surface of the nylon-brush. The body of the kit was produced by means of a commercial 3D-printer, in which ABS (acrylonitrile butadiene styrene) was used as the starting material. Meanwhile, a small nylon-brush was embedded inside a 3D-printed plastic cell, in which a solvent was supplied to rinse the brush by means of capillary action. The size and weight of the kit were 1 g and 4 cm, respectively. The kit is disposable and it has various functions, including non-invasive sampling, sample-evaporation and ionization. As a result, when a type of pesticide was selected as the test sample (dimethoate; C5H12NO3PS2), the limit of detection was determined to be 0.1 μg/mL. Collecting the pesticide from a leaf-surface (lettuce) was also successful. The process for fabricating the nylon-brush kit and the optimized experimental conditions are reported herein.
Collapse
Affiliation(s)
- Jen-Ying Liu
- Department of Chemistry, National Taiwan Normal University
| | - Pei-Chun Chen
- Department of Chemistry, National Taiwan Normal University
| | - Yea-Wenn Liou
- Department of Chemistry, National Taiwan Normal University
| | - Kai-Yin Chang
- Department of Chemistry, National Taiwan Normal University
| | | |
Collapse
|
39
|
Meher AK, Chen YC. Combination of Raman Spectroscopy and Mass Spectrometry for Online Chemical Analysis. Anal Chem 2016; 88:9151-7. [PMID: 27571682 DOI: 10.1021/acs.analchem.6b02152] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Mass spectrometry (MS) and Raman spectroscopy are complementary analytical techniques used to provide information related to chemical structures and functional groups of target analytes. Each instrument provides specific chemical information. If these two analytical tools are coupled online, comprehensive structural information can be simultaneously collected from the analytes of interest without losing any important chemical information. Nevertheless, exploring a suitable interface for coupling of these analytical tools, which are governed with different operation principles, remains challenging. In this study, we used a small piece of tissue paper as an interface for hyphenating a Raman spectroscope and a mass spectrometer online. The paper played multiroles as sample loading substrate and an emitter to generate electrospray. Furthermore, it can facilitate surface-enhanced Raman spectroscopic analysis to improve analyte signals in Raman spectra. A sample droplet was placed on the tissue paper located close to the laser of the Raman spectroscope and the inlet of mass spectrometer. Raman spectra were first collected by the Raman spectroscope through laser irradiation followed by generation of electrospray on the edge of the paper for MS analysis. Positional isomers were used as model samples to demonstrate the effectiveness of the hyphenated analytical tool in distinguishing isomers. The feasibility of using this Raman-MS hyphenated technique for monitoring chemical reactions online in real time was also investigated.
Collapse
Affiliation(s)
- Anil Kumar Meher
- Department of Applied Chemistry, National Chiao Tung University , Hsinchu 300, Taiwan
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University , Hsinchu 300, Taiwan
| |
Collapse
|
40
|
Liu J, Gu Z, Yao S, Zhang Z, Chen B. Rapid analysis of Callicarpa L. using direct spray ionization mass spectrometry. J Pharm Biomed Anal 2016; 124:93-103. [DOI: 10.1016/j.jpba.2016.02.030] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2015] [Revised: 02/22/2016] [Accepted: 02/22/2016] [Indexed: 11/25/2022]
|
41
|
Correa DN, Santos JM, Eberlin LS, Eberlin MN, Teunissen SF. Forensic Chemistry and Ambient Mass Spectrometry: A Perfect Couple Destined for a Happy Marriage? Anal Chem 2016; 88:2515-26. [DOI: 10.1021/acs.analchem.5b02397] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Deleon N. Correa
- ThoMSon
Mass Spectrometry Laboratory, University of Campinas—UNICAMP, Campinas, São Paulo 13083-970, Brazil
- Technical-Scientific Police Superintendence—IC-SPTC-SP, São Paulo, São Paulo 05507-06, Brazil
| | - Jandyson M. Santos
- ThoMSon
Mass Spectrometry Laboratory, University of Campinas—UNICAMP, Campinas, São Paulo 13083-970, Brazil
| | - Livia S. Eberlin
- Department
of Chemistry, The University of Texas at Austin, Austin, Texas 78712 United States
| | - Marcos N. Eberlin
- ThoMSon
Mass Spectrometry Laboratory, University of Campinas—UNICAMP, Campinas, São Paulo 13083-970, Brazil
| | - Sebastiaan F. Teunissen
- ThoMSon
Mass Spectrometry Laboratory, University of Campinas—UNICAMP, Campinas, São Paulo 13083-970, Brazil
| |
Collapse
|
42
|
D'Aronco S, Calandra E, Crotti S, Toffoli G, Marangon E, Posocco B, Traldi P, Agostini M. Field-assisted paper spray mass spectrometry for the quantitative evaluation of imatinib levels in plasma. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2016; 22:217-228. [PMID: 27882887 DOI: 10.1255/ejms.1437] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Drug levels in patients' bloodstreams vary among individuals and consequently therapeutic drug monitoring (TDM) is fundamental to controlling the effective therapeutic range. For TDM purposes, different analytical approaches have been used, mainly based on immunoassay, liquid chromatography- ultraviolet, liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. More recently a matrix-assisted laser desorption/ionisation method has been proposed for the determination of irinotecan levels in the plasma of subjects under therapy and this method has been cross- validated by comparison with data achieved by LC-MS/MS. However, to reach an effective point-of-care monitoring of plasma drug concentrations, a TDM platform technology for fast, accurate, low-cost assays is required. In this frame, recently the use of paper spray mass spectrometry, which is becoming a popular and widely employed MS method, has been proposed. In this paper we report the results obtained by the development of a paper spray-based method for quantitative analysis in plasma samples of imatinib, a new generation of anticancer drug. Preliminary experiments showed that poor sensitivity, reproducibility and linear response were obtained by the "classical" paper spray set-up. In order to achieve better results, it was thought of interest to operate in presence of a higher and more homogeneous electrical field. For this aim, a stainless steel needle connected with the high voltage power supply was mounted below the paper triangle. Furthermore, in order to obtain valid quantitative data, we analysed the role of the different equilibria participating to the phenomena occurring in paper spray experiments, depending either on instrumental parameters or on the chemical nature of analyte and solvents. A calibration curve was obtained by spiking plasma samples containing different amounts of imatinib (1) with known amounts of deuterated imatinib (1d3) as internal standard, with molar ratios [1]/[1d3] in the range 0.00-2.00. A quite good linearity was obtained (R2 = 0.975) and some experiments performed on spiked plasma samples with known amounts of 1 confirmed the validity of this method.
Collapse
Affiliation(s)
- Sara D'Aronco
- Nano-inspired Biomedicine Lab., Institute of Paediatric Research - Città della Speranza, Corso Stati Uniti 4, 35127 Padova, Italy
| | - Eleonora Calandra
- Nano-inspired Biomedicine Lab., Institute of Paediatric Research - Città della Speranza, Corso Stati Uniti 4, 35127 Padova, Italy
| | - Sara Crotti
- Nano-inspired Biomedicine Lab., Institute of Paediatric Research - Città della Speranza, Corso Stati Uniti 4, 35127 Padova, Italy
| | - Giuseppe Toffoli
- Experimental and Clinical Pharmacology Unit, Centro di Riferimento Oncologico, IRCCS National Cancer Institute, Via Franco Gallini 2, Aviano, 33081, PN, Italy
| | - Elena Marangon
- Experimental and Clinical Pharmacology Unit, Centro di Riferimento Oncologico, IRCCS National Cancer Institute, Via Franco Gallini 2, Aviano, 33081, PN, Italy
| | - Bianca Posocco
- Experimental and Clinical Pharmacology Unit, Centro di Riferimento Oncologico, IRCCS National Cancer Institute, Via Franco Gallini 2, Aviano, 33081, PN, Italy
| | - Pietro Traldi
- Nano-inspired Biomedicine Lab., Institute of Paediatric Research - Città della Speranza, Corso Stati Uniti 4, 35127 Padova, Italy.
| | - Marco Agostini
- Nano-inspired Biomedicine Lab., Institute of Paediatric Research - Città della Speranza, Corso Stati Uniti 4, 35127 Padova, Italy and Surgical Clinic, Department of Surgical, Oncological and Gastroenterological Sciences, University of Padova, Via Nicolò Giustiniani 2, Padova, 35128, Italy and Department of Nanomedicine, The Methodist Hospital Research Institute, 6670 Bertner Avenue, Houston, 77030, TX, USA
| |
Collapse
|
43
|
Klampfl CW, Himmelsbach M. Direct ionization methods in mass spectrometry: An overview. Anal Chim Acta 2015; 890:44-59. [DOI: 10.1016/j.aca.2015.07.012] [Citation(s) in RCA: 94] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Revised: 07/15/2015] [Accepted: 07/31/2015] [Indexed: 12/15/2022]
|
44
|
Abstract
Ambient ionization MS has become very popular in analytical science and has now evolved as an effective analytical tool in metabolomics, biological tissue imaging, protein and small molecule drug analysis, where biological samples are probed in a rapid and direct fashion with minimal sample preparation at ambient conditions. However, certain inherent challenges continue to hinder the vibrant prospects of these methods for in situ analyses or to replace conventional methods in bioanalysis. This review provides an introduction to the field and its application in bioanalysis, with an emphasis on the most recent developments and applications. Furthermore, ongoing challenges or limitations related to quantitation, sensitivity, selectivity, instrumentation and mass range of these ambient methods will also be discussed.
Collapse
|
45
|
Zhang M, Lin F, Xu J, Xu W. Membrane electrospray ionization for direct ultrasensitive biomarker quantitation in biofluids using mass spectrometry. Anal Chem 2015; 87:3123-8. [PMID: 25728048 DOI: 10.1021/acs.analchem.5b00467] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The ability of rapid biomarker quantitation in raw biological samples would expand the application of mass spectrometry in clinical diagnosis. Up until now, the conventional chromatography-mass spectrometry method is time-consuming in both sample preparation and chromatography separation processes, while ambient ionization methods normally suffer from sensitivity. The membrane electrospray ionization (MESI) introduced in this study could not only achieve sensitive biomolecule quantitation, but also minimize the sample handling process. As a unique feature of MESI, both vertical and horizontal chemical separations could be achieved in real-time. With the capability of mass-selectively minimizing matrix effects from salts, small molecules, and macromolecules, ultrasensitive detection of cytochrome C (>500-fold sensitivity improvement) in raw urine samples was demonstrated in less than 20 min.
Collapse
Affiliation(s)
- Mei Zhang
- †National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China, 102206.,‡State Key Laboratory for Infectious Disease Prevention and Control, Beijing, China, 102206.,§Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China, 310003
| | - Fankai Lin
- ⊥School of Life Science, Beijing Institute of Technology, Beijing, China, 100081
| | - Jianguo Xu
- †National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China, 102206.,‡State Key Laboratory for Infectious Disease Prevention and Control, Beijing, China, 102206.,§Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China, 310003
| | - Wei Xu
- ⊥School of Life Science, Beijing Institute of Technology, Beijing, China, 100081
| |
Collapse
|
46
|
Jarmusch AK, Kerian KS, Pirro V, Peat T, Thompson CA, Ramos-Vara JA, Childress MO, Cooks RG. Characteristic lipid profiles of canine non-Hodgkin's lymphoma from surgical biopsy tissue sections and fine needle aspirate smears by desorption electrospray ionization – mass spectrometry. Analyst 2015; 140:6321-9. [DOI: 10.1039/c5an00825e] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Exploring lipid information characteristic of non-Hodgkin's lymphoma using DESI – mass spectrometry.
Collapse
Affiliation(s)
- Alan K. Jarmusch
- Department of Chemistry and Center for Analytical Instrumentation Development
- Purdue University
- 560 Oval Drive
- USA
| | - Kevin S. Kerian
- Department of Chemistry and Center for Analytical Instrumentation Development
- Purdue University
- 560 Oval Drive
- USA
| | - Valentina Pirro
- Department of Chemistry and Center for Analytical Instrumentation Development
- Purdue University
- 560 Oval Drive
- USA
| | - Tyler Peat
- Department of Comparative Pathobiology
- College of Veterinary Medicine
- Purdue University
- West Lafayette
- USA
| | - Craig A. Thompson
- Department of Comparative Pathobiology
- College of Veterinary Medicine
- Purdue University
- West Lafayette
- USA
| | - José A. Ramos-Vara
- Department of Comparative Pathobiology
- College of Veterinary Medicine
- Purdue University
- West Lafayette
- USA
| | - Michael O. Childress
- Department of Veterinary Clinical Sciences
- College of Veterinary Medicine
- Purdue University
- West Lafayette
- USA
| | - R. Graham Cooks
- Department of Chemistry and Center for Analytical Instrumentation Development
- Purdue University
- 560 Oval Drive
- USA
| |
Collapse
|