1
|
Uguz I, Ohayon D, Yilmaz S, Griggs S, Sheelamanthula R, Fabbri JD, McCulloch I, Inal S, Shepard KL. Complementary integration of organic electrochemical transistors for front-end amplifier circuits of flexible neural implants. Sci Adv 2024; 10:eadi9710. [PMID: 38517957 PMCID: PMC10959418 DOI: 10.1126/sciadv.adi9710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 02/14/2024] [Indexed: 03/24/2024]
Abstract
The ability to amplify, translate, and process small ionic potential fluctuations of neural processes directly at the recording site is essential to improve the performance of neural implants. Organic front-end analog electronics are ideal for this application, allowing for minimally invasive amplifiers owing to their tissue-like mechanical properties. Here, we demonstrate fully organic complementary circuits by pairing depletion- and enhancement-mode p- and n-type organic electrochemical transistors (OECTs). With precise geometry tuning and a vertical device architecture, we achieve overlapping output characteristics and integrate them into amplifiers with single neuronal dimensions (20 micrometers). Amplifiers with combined p- and n-OECTs result in voltage-to-voltage amplification with a gain of >30 decibels. We also leverage depletion and enhancement-mode p-OECTs with matching characteristics to demonstrate a differential recording capability with high common mode rejection rate (>60 decibels). Integrating OECT-based front-end amplifiers into a flexible shank form factor enables single-neuron recording in the mouse cortex with on-site filtering and amplification.
Collapse
Affiliation(s)
- Ilke Uguz
- Columbia University, New York, NY, USA
| | - David Ohayon
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
- Institute of Functional Intelligent Materials (IFIM), National University of Singapore, 117544, Singapore
| | | | - Sophie Griggs
- Department of Chemistry, Chemistry Research Laboratory, University of Oxford, Oxford OX1 3TA, UK
| | - Rajendar Sheelamanthula
- Physical Science and Engineering Division, KAUST Solar Center, KAUST, Thuwal 23955-6900, Saudi Arabia
| | | | - Iain McCulloch
- Department of Chemistry, Chemistry Research Laboratory, University of Oxford, Oxford OX1 3TA, UK
- Physical Science and Engineering Division, KAUST Solar Center, KAUST, Thuwal 23955-6900, Saudi Arabia
| | - Sahika Inal
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
| | | |
Collapse
|
2
|
Salavatian S, Robbins EM, Kuwabara Y, Castagnola E, Cui XT, Mahajan A. Real-time in vivo thoracic spinal glutamate sensing during myocardial ischemia. Am J Physiol Heart Circ Physiol 2023; 325:H1304-H1317. [PMID: 37737733 PMCID: PMC10908408 DOI: 10.1152/ajpheart.00299.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 09/18/2023] [Accepted: 09/18/2023] [Indexed: 09/23/2023]
Abstract
In the spinal cord, glutamate serves as the primary excitatory neurotransmitter. Monitoring spinal glutamate concentrations offers valuable insights into spinal neural processing. Consequently, spinal glutamate concentration has the potential to emerge as a useful biomarker for conditions characterized by increased spinal neural network activity, especially when uptake systems become dysfunctional. In this study, we developed a multichannel custom-made flexible glutamate-sensing probe for the large-animal model that is capable of measuring extracellular glutamate concentrations in real time and in vivo. We assessed the probe's sensitivity and specificity through in vitro and ex vivo experiments. Remarkably, this developed probe demonstrates nearly instantaneous glutamate detection and allows continuous monitoring of glutamate concentrations. Furthermore, we evaluated the mechanical and sensing performance of the probe in vivo, within the pig spinal cord. Moreover, we applied the glutamate-sensing method using the flexible probe in the context of myocardial ischemia-reperfusion (I/R) injury. During I/R injury, cardiac sensory neurons in the dorsal root ganglion transmit excitatory signals to the spinal cord, resulting in sympathetic activation that potentially leads to fatal arrhythmias. We have successfully shown that our developed glutamate-sensing method can detect this spinal network excitation during myocardial ischemia. This study illustrates a novel technique for measuring spinal glutamate at different spinal cord levels as a surrogate for the spinal neural network activity during cardiac interventions that engage the cardio-spinal neural pathway.NEW & NOTEWORTHY In this study, we have developed a new flexible sensing probe to perform an in vivo measurement of spinal glutamate signaling in a large animal model. Our initial investigations involved precise testing of this probe in both in vitro and ex vivo environments. We accurately assessed the sensitivity and specificity of our glutamate-sensing probe and demonstrated its performance. We also evaluated the performance of our developed flexible probe during the insertion and compared it with the stiff probe during animal movement. Subsequently, we used this innovative technique to monitor the spinal glutamate signaling during myocardial ischemia and reperfusion that can cause fatal ventricular arrhythmias. We showed that glutamate concentration increases during the myocardial ischemia, persists during the reperfusion, and is associated with sympathoexcitation and increases in myocardial substrate excitability.
Collapse
Affiliation(s)
- Siamak Salavatian
- Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
- Division of Cardiology, Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Elaine Marie Robbins
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Yuki Kuwabara
- Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Elisa Castagnola
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
- Center for Neural Basis of Cognition, Pittsburgh, Pennsylvania, United States
- McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania, United States
| | - Aman Mahajan
- Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| |
Collapse
|
3
|
Perna A, Angotzi GN, Berdondini L, Ribeiro JF. Advancing the interfacing performances of chronically implantable neural probes in the era of CMOS neuroelectronics. Front Neurosci 2023; 17:1275908. [PMID: 38027514 PMCID: PMC10644322 DOI: 10.3389/fnins.2023.1275908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 10/10/2023] [Indexed: 12/01/2023] Open
Abstract
Tissue penetrating microelectrode neural probes can record electrophysiological brain signals at resolutions down to single neurons, making them invaluable tools for neuroscience research and Brain-Computer-Interfaces (BCIs). The known gradual decrease of their electrical interfacing performances in chronic settings, however, remains a major challenge. A key factor leading to such decay is Foreign Body Reaction (FBR), which is the cascade of biological responses that occurs in the brain in the presence of a tissue damaging artificial device. Interestingly, the recent adoption of Complementary Metal Oxide Semiconductor (CMOS) technology to realize implantable neural probes capable of monitoring hundreds to thousands of neurons simultaneously, may open new opportunities to face the FBR challenge. Indeed, this shift from passive Micro Electro-Mechanical Systems (MEMS) to active CMOS neural probe technologies creates important, yet unexplored, opportunities to tune probe features such as the mechanical properties of the probe, its layout, size, and surface physicochemical properties, to minimize tissue damage and consequently FBR. Here, we will first review relevant literature on FBR to provide a better understanding of the processes and sources underlying this tissue response. Methods to assess FBR will be described, including conventional approaches based on the imaging of biomarkers, and more recent transcriptomics technologies. Then, we will consider emerging opportunities offered by the features of CMOS probes. Finally, we will describe a prototypical neural probe that may meet the needs for advancing clinical BCIs, and we propose axial insertion force as a potential metric to assess the influence of probe features on acute tissue damage and to control the implantation procedure to minimize iatrogenic injury and subsequent FBR.
Collapse
Affiliation(s)
- Alberto Perna
- Microtechnology for Neuroelectronics Lab, Fondazione Istituto Italiano di Tecnologia, Neuroscience and Brain Technologies, Genova, Italy
- The Open University Affiliated Research Centre at Istituto Italiano di Tecnologia (ARC@IIT), Istituto Italiano di Tecnologia, Genova, Italy
| | - Gian Nicola Angotzi
- Microtechnology for Neuroelectronics Lab, Fondazione Istituto Italiano di Tecnologia, Neuroscience and Brain Technologies, Genova, Italy
| | - Luca Berdondini
- Microtechnology for Neuroelectronics Lab, Fondazione Istituto Italiano di Tecnologia, Neuroscience and Brain Technologies, Genova, Italy
| | - João Filipe Ribeiro
- Microtechnology for Neuroelectronics Lab, Fondazione Istituto Italiano di Tecnologia, Neuroscience and Brain Technologies, Genova, Italy
| |
Collapse
|
4
|
Qian S, Lin HA, Pan Q, Zhang S, Zhang Y, Geng Z, Wu Q, He Y, Zhu B. Chemically revised conducting polymers with inflammation resistance for intimate bioelectronic electrocoupling. Bioact Mater 2023; 26:24-51. [PMID: 36875055 PMCID: PMC9975642 DOI: 10.1016/j.bioactmat.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 01/26/2023] [Accepted: 02/10/2023] [Indexed: 02/23/2023] Open
Abstract
Conducting polymers offer attractive mixed ionic-electronic conductivity, tunable interfacial barrier with metal, tissue matchable softness, and versatile chemical functionalization, making them robust to bridge the gap between brain tissue and electronic circuits. This review focuses on chemically revised conducting polymers, combined with their superior and controllable electrochemical performance, to fabricate long-term bioelectronic implants, addressing chronic immune responses, weak neuron attraction, and long-term electrocommunication instability challenges. Moreover, the promising progress of zwitterionic conducting polymers in bioelectronic implants (≥4 weeks stable implantation) is highlighted, followed by a comment on their current evolution toward selective neural coupling and reimplantable function. Finally, a critical forward look at the future of zwitterionic conducting polymers for in vivo bioelectronic devices is provided.
Collapse
Affiliation(s)
- Sihao Qian
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China.,School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Hsing-An Lin
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Qichao Pan
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Shuhua Zhang
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Yunhua Zhang
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Zhi Geng
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Qing Wu
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| | - Yong He
- Innovation Center for Textile Science and Technology, Donghua University, Shanghai, 201620, China
| | - Bo Zhu
- School of Materials Science and Engineering & Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, 200444, China
| |
Collapse
|
5
|
Rouzitalab A, Boulay CB, Park J, Sachs AJ. Intracortical brain-computer interfaces in primates: a review and outlook. Biomed Eng Lett 2023; 13:375-390. [PMID: 37519868 PMCID: PMC10382423 DOI: 10.1007/s13534-023-00286-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 05/04/2023] [Accepted: 05/14/2023] [Indexed: 08/01/2023] Open
Abstract
Brain-computer interfaces (BCI) translate brain signals into artificial output to restore or replace natural central nervous system (CNS) functions. Multiple processes, including sensorimotor integration, decision-making, motor planning, execution, and updating, are involved in any movement. For example, a BCI may be better able to restore naturalistic motor behaviors if it uses signals from multiple brain areas and decodes natural behaviors' cognitive and motor aspects. This review provides an overview of the preliminary information necessary to plan a BCI project focusing on intracortical implants in primates. Since the brain structure and areas of non-human primates (NHP) are similar to humans, exploring the result of NHP studies will eventually benefit human BCI studies. The different types of BCI systems based on the target cortical area, types of signals, and decoding methods will be discussed. In addition, various successful state-of-the-art cases will be reviewed in more detail, focusing on the general algorithm followed in the real-time system. Finally, an outlook for improving the current BCI research studies will be debated.
Collapse
Affiliation(s)
- Alireza Rouzitalab
- School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON K1N 6N5 Canada
- The Ottawa Hospital Research Institute, Ottawa, ON Canada
| | | | - Jeongwon Park
- School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON K1N 6N5 Canada
- Department of Electrical and Biomedical Engineering, University of Nevada, Reno, NV 89557 USA
| | - Adam J. Sachs
- The Ottawa Hospital Research Institute, Ottawa, ON Canada
- The University of Ottawa Brain and Mind Research Institute, Ottawa, ON Canada
- Division of Neurosurgery, Department of Surgery, The Ottawa Hospital, Ottawa, ON Canada
| |
Collapse
|
6
|
Salavatian S, Robbins EM, Kuwabara Y, Castagnola E, Cui XT, Mahajan A. Real-time in vivo thoracic spinal glutamate sensing reveals spinal hyperactivity during myocardial ischemia. bioRxiv 2023:2023.03.11.531911. [PMID: 36993301 PMCID: PMC10054946 DOI: 10.1101/2023.03.11.531911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Myocardial ischemia-reperfusion (IR) can cause ventricular arrhythmias and sudden cardiac death via sympathoexcitation. The spinal cord neural network is crucial in triggering these arrhythmias and evaluating its neurotransmitter activity during IR is critical for understanding ventricular excitability control. To assess the real-time in vivo spinal neural activity in a large animal model, we developed a flexible glutamate-sensing multielectrode array. To record the glutamate signaling during IR injury, we inserted the probe into the dorsal horn of the thoracic spinal cord at the T2-T3 where neural signals generated by the cardiac sensory neurons are processed and provide sympathoexcitatory feedback to the heart. Using the glutamate sensing probe, we found that the spinal neural network was excited during IR, especially after 15 mins, and remained elevated during reperfusion. Higher glutamate signaling was correlated with the reduction in the cardiac myocyte activation recovery interval, showing higher sympathoexcitation, as well as dispersion of the repolarization which is a marker for increased risk of arrhythmias. This study illustrates a new technique for measuring the spinal glutamate at different spinal cord levels as a surrogate for the spinal neural network activity during cardiac interventions that engage the cardio-spinal neural pathway. Graphical abstract
Collapse
|
7
|
Salahuddin U, Gao PX. Signal Generation, Acquisition, and Processing in Brain Machine Interfaces: A Unified Review. Front Neurosci 2021; 15:728178. [PMID: 34588951 PMCID: PMC8475516 DOI: 10.3389/fnins.2021.728178] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 08/18/2021] [Indexed: 11/13/2022] Open
Abstract
Brain machine interfaces (BMIs), or brain computer interfaces (BCIs), are devices that act as a medium for communications between the brain and the computer. It is an emerging field with numerous applications in domains of prosthetic devices, robotics, communication technology, gaming, education, and security. It is noted in such a multidisciplinary field, many reviews have surveyed on various focused subfields of interest, such as neural signaling, microelectrode fabrication, and signal classification algorithms. A unified review is lacking to cover and link all the relevant areas in this field. Herein, this review intends to connect on the relevant areas that circumscribe BMIs to present a unified script that may help enhance our understanding of BMIs. Specifically, this article discusses signal generation within the cortex, signal acquisition using invasive, non-invasive, or hybrid techniques, and the signal processing domain. The latest development is surveyed in this field, particularly in the last decade, with discussions regarding the challenges and possible solutions to allow swift disruption of BMI products in the commercial market.
Collapse
Affiliation(s)
- Usman Salahuddin
- Institute of Materials Science, University of Connecticut, Storrs, CT, United States
| | - Pu-Xian Gao
- Institute of Materials Science, University of Connecticut, Storrs, CT, United States
- Department of Materials Science and Engineering, University of Connecticut, Storrs, CT, United States
| |
Collapse
|
8
|
Liu X, Bibineyshvili Y, Robles DA, Boreland AJ, Margolis DJ, Shreiber DI, Zahn JD. Fabrication of a Multilayer Implantable Cortical Microelectrode Probe to Improve Recording Potential. J Microelectromech Syst 2021; 30:569-581. [PMID: 34539168 PMCID: PMC8445332 DOI: 10.1109/jmems.2021.3092230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Intracortical neural probes are a key enabling technology for acquiring high fidelity neural signals within the cortex. They are viewed as a crucial component of brain-computer interfaces (BCIs) in order to record electrical activities from neurons within the brain. Smaller, more flexible, polymer-based probes have been investigated for their potential to limit the acute and chronic neural tissue response. Conventional methods of patterning electrodes and connecting traces on a single supporting layer can limit the number of recording sites which can be defined, particularly when designing narrower probes. We present a novel strategy of increasing the number of recording sites without proportionally increasing the size of the probe by using a multilayer fabrication process to vertically layer recording traces on multiple Parylene support layers, allowing more recording traces to be defined on a smaller probe width. Using this approach, we are able to define 16 electrodes on 4 supporting layers (4 electrodes per layer), each with a 30 μm diameter recording window and 5 μm wide connecting trace defined by conventional LWUV lithography, on an 80 μm wide by 9 μm thick microprobe. Prior to in vitro and in vivo validation, the multilayer probes are electrically characterized via impedance spectroscopy and evaluating crosstalk between adjacent layers. Demonstration of acute in vitro recordings in a cerebral organoid model and in vivo recordings in a murine model indicate the probe's capability for single unit recordings. This work demonstrates the ability to fabricate smaller, more compliant neural probes without sacrificing electrode density.
Collapse
Affiliation(s)
- Xin Liu
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ 08854 USA
| | - Yelena Bibineyshvili
- Department of Cell Biology and Neuroscience, Rutgers University, Piscataway, NJ 08854 USA
| | - Denise A Robles
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ 08854 USA
| | - Andrew J Boreland
- Department of Cell Biology and Neuroscience, Rutgers University, Piscataway, NJ 08854 USA
| | - David J Margolis
- Department of Cell Biology and Neuroscience, Rutgers University, Piscataway, NJ 08854 USA
| | - David I Shreiber
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ 08854 USA
| | - Jeffrey D Zahn
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ 08854 USA
| |
Collapse
|
9
|
Pimenta S, Rodrigues JA, Machado F, Ribeiro JF, Maciel MJ, Bondarchuk O, Monteiro P, Gaspar J, Correia JH, Jacinto L. Double-Layer Flexible Neural Probe With Closely Spaced Electrodes for High-Density in vivo Brain Recordings. Front Neurosci 2021; 15:663174. [PMID: 34211364 PMCID: PMC8239195 DOI: 10.3389/fnins.2021.663174] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 05/19/2021] [Indexed: 11/13/2022] Open
Abstract
Flexible polymer neural probes are an attractive emerging approach for invasive brain recordings, given that they can minimize the risks of brain damage or glial scaring. However, densely packed electrode sites, which can facilitate neuronal data analysis, are not widely available in flexible probes. Here, we present a new flexible polyimide neural probe, based on standard and low-cost lithography processes, which has 32 closely spaced 10 μm diameter gold electrode sites at two different depths from the probe surface arranged in a matrix, with inter-site distances of only 5 μm. The double-layer design and fabrication approach implemented also provides additional stiffening just sufficient to prevent probe buckling during brain insertion. This approach avoids typical laborious augmentation strategies used to increase flexible probes’ mechanical rigidity while allowing a small brain insertion footprint. Chemical composition analysis and metrology of structural, mechanical, and electrical properties demonstrated the viability of this fabrication approach. Finally, in vivo functional assessment tests in the mouse cortex were performed as well as histological assessment of the insertion footprint, validating the biological applicability of this flexible neural probe for acquiring high quality neuronal recordings with high signal to noise ratio (SNR) and reduced acute trauma.
Collapse
Affiliation(s)
- Sara Pimenta
- CMEMS-UMinho, Department of Industrial Electronics, University of Minho, Guimarães, Portugal
| | - José A Rodrigues
- CMEMS-UMinho, Department of Industrial Electronics, University of Minho, Guimarães, Portugal
| | - Francisca Machado
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - João F Ribeiro
- CMEMS-UMinho, Department of Industrial Electronics, University of Minho, Guimarães, Portugal
| | - Marino J Maciel
- CMEMS-UMinho, Department of Industrial Electronics, University of Minho, Guimarães, Portugal
| | | | - Patricia Monteiro
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - João Gaspar
- International Iberian Nanotechnology Laboratory (INL), Braga, Portugal
| | - José H Correia
- CMEMS-UMinho, Department of Industrial Electronics, University of Minho, Guimarães, Portugal
| | - Luis Jacinto
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| |
Collapse
|
10
|
McGlynn E, Nabaei V, Ren E, Galeote‐Checa G, Das R, Curia G, Heidari H. The Future of Neuroscience: Flexible and Wireless Implantable Neural Electronics. Adv Sci (Weinh) 2021; 8:2002693. [PMID: 34026431 PMCID: PMC8132070 DOI: 10.1002/advs.202002693] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 01/15/2021] [Indexed: 05/04/2023]
Abstract
Neurological diseases are a prevalent cause of global mortality and are of growing concern when considering an ageing global population. Traditional treatments are accompanied by serious side effects including repeated treatment sessions, invasive surgeries, or infections. For example, in the case of deep brain stimulation, large, stiff, and battery powered neural probes recruit thousands of neurons with each pulse, and can invoke a vigorous immune response. This paper presents challenges in engineering and neuroscience in developing miniaturized and biointegrated alternatives, in the form of microelectrode probes. Progress in design and topology of neural implants has shifted the goal post toward highly specific recording and stimulation, targeting small groups of neurons and reducing the foreign body response with biomimetic design principles. Implantable device design recommendations, fabrication techniques, and clinical evaluation of the impact flexible, integrated probes will have on the treatment of neurological disorders are provided in this report. The choice of biocompatible material dictates fabrication techniques as novel methods reduce the complexity of manufacture. Wireless power, the final hurdle to truly implantable neural interfaces, is discussed. These aspects are the driving force behind continued research: significant breakthroughs in any one of these areas will revolutionize the treatment of neurological disorders.
Collapse
Affiliation(s)
- Eve McGlynn
- Microelectronics LabJames Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUnited Kingdom
| | - Vahid Nabaei
- Microelectronics LabJames Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUnited Kingdom
| | - Elisa Ren
- Laboratory of Experimental Electroencephalography and NeurophysiologyDepartment of BiomedicalMetabolic and Neural SciencesUniversity of Modena and Reggio EmiliaModena41125Italy
| | - Gabriel Galeote‐Checa
- Microelectronics LabJames Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUnited Kingdom
| | - Rupam Das
- Microelectronics LabJames Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUnited Kingdom
| | - Giulia Curia
- Laboratory of Experimental Electroencephalography and NeurophysiologyDepartment of BiomedicalMetabolic and Neural SciencesUniversity of Modena and Reggio EmiliaModena41125Italy
| | - Hadi Heidari
- Microelectronics LabJames Watt School of EngineeringUniversity of GlasgowGlasgowG12 8QQUnited Kingdom
| |
Collapse
|
11
|
Thielen B, Meng E. A comparison of insertion methods for surgical placement of penetrating neural interfaces. J Neural Eng 2021; 18:10.1088/1741-2552/abf6f2. [PMID: 33845469 PMCID: PMC8600966 DOI: 10.1088/1741-2552/abf6f2] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 04/12/2021] [Indexed: 02/07/2023]
Abstract
Many implantable electrode arrays exist for the purpose of stimulating or recording electrical activity in brain, spinal, or peripheral nerve tissue, however most of these devices are constructed from materials that are mechanically rigid. A growing body of evidence suggests that the chronic presence of these rigid probes in the neural tissue causes a significant immune response and glial encapsulation of the probes, which in turn leads to gradual increase in distance between the electrodes and surrounding neurons. In recording electrodes, the consequence is the loss of signal quality and, therefore, the inability to collect electrophysiological recordings long term. In stimulation electrodes, higher current injection is required to achieve a comparable response which can lead to tissue and electrode damage. To minimize the impact of the immune response, flexible neural probes constructed with softer materials have been developed. These flexible probes, however, are often not strong enough to be inserted on their own into the tissue, and instead fail via mechanical buckling of the shank under the force of insertion. Several strategies have been developed to allow the insertion of flexible probes while minimizing tissue damage. It is critical to keep these strategies in mind during probe design in order to ensure successful surgical placement. In this review, existing insertion strategies will be presented and evaluated with respect to surgical difficulty, immune response, ability to reach the target tissue, and overall limitations of the technique. Overall, the majority of these insertion techniques have only been evaluated for the insertion of a single probe and do not quantify the accuracy of probe placement. More work needs to be performed to evaluate and optimize insertion methods for accurate placement of devices and for devices with multiple probes.
Collapse
Affiliation(s)
- Brianna Thielen
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| | - Ellis Meng
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| |
Collapse
|
12
|
Apollo NV, Murphy B, Prezelski K, Driscoll N, Richardson AG, Lucas TH, Vitale F. Gels, jets, mosquitoes, and magnets: a review of implantation strategies for soft neural probes. J Neural Eng 2020; 17:041002. [PMID: 32759476 PMCID: PMC8152109 DOI: 10.1088/1741-2552/abacd7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Implantable neuroelectronic interfaces have enabled breakthrough advances in the clinical diagnosis and treatment of neurological disorders, as well as in fundamental studies of brain function, behavior, and disease. Intracranial electroencephalography (EEG) mapping with stereo-EEG (sEEG) depth electrodes is routinely adopted for precise epilepsy diagnostics and surgical treatment, while deep brain stimulation has become the standard of care for managing movement disorders. Intracortical microelectrode arrays for high-fidelity recordings of neural spiking activity have led to impressive demonstrations of the power of brain-machine interfaces for motor and sensory functional recovery. Yet, despite the rapid pace of technology development, the issue of establishing a safe, long-term, stable, and functional interface between neuroelectronic devices and the host brain tissue still remains largely unresolved. A body of work spanning at least the last 15 years suggests that safe, chronic integration between invasive electrodes and the brain requires a close match between the mechanical properties of man-made components and the neural tissue. In other words, the next generation of invasive electrodes should be soft and compliant, without sacrificing biological and chemical stability. Soft neuroelectronic interfaces, however, pose a new and significant surgical challenge: bending and buckling during implantation that can preclude accurate and safe device placement. In this topical review, we describe the next generation of soft electrodes and the surgical implantation methods for safe and precise insertion into brain structures. We provide an overview of the most recent innovations in the field of insertion strategies for flexible neural electrodes such as dissolvable or biodegradable carriers, microactuators, biologically-inspired support structures, and electromagnetic drives. In our analysis, we also highlight approaches developed in different fields, such as robotic surgery, which could be potentially adapted and translated to the insertion of flexible neural probes.
Collapse
Affiliation(s)
- Nicholas V Apollo
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania, 19104, United States of America
| | - Brendan Murphy
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania, 19104, United States of America
- These authors contributed equally
| | - Kayla Prezelski
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania, 19104, United States of America
- These authors contributed equally
| | - Nicolette Driscoll
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania, 19104, United States of America
| | - Andrew G Richardson
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
| | - Timothy H Lucas
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
| | - Flavia Vitale
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania, 19104, United States of America
- These authors contributed equally
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States of America
- Department of Physical Medicine & Rehabilitation, University of Pennsylvania, Philadelphia, Pennsylvania, 19104, United States of America
| |
Collapse
|
13
|
Wang X, Weltman Hirschberg A, Xu H, Slingsby-Smith Z, Lecomte A, Scholten K, Song D, Meng E. A Parylene Neural Probe Array for Multi-Region Deep Brain Recordings. J Microelectromech Syst 2020; 29:499-513. [PMID: 35663261 PMCID: PMC9164222 DOI: 10.1109/jmems.2020.3000235] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
A Parylene C polymer neural probe array with 64 electrodes purposefully positioned across 8 individual shanks to anatomically match specific regions of the hippocampus was designed, fabricated, characterized, and implemented in vivo for enabling recording in deep brain regions in freely moving rats. Thin film polymer arrays were fabricated using surface micromachining techniques and mechanically braced to prevent buckling during surgical implantation. Importantly, the mechanical bracing technique developed in this work involves a novel biodegradable polymer brace that temporarily reduces shank length and consequently, increases its stiffness during implantation, therefore enabling access to deeper brain regions while preserving a low original cross-sectional area of the shanks. The resulting mechanical properties of braced shanks were evaluated at the benchtop. Arrays were then implemented in vivo in freely moving rats, achieving both acute and chronic recordings from the pyramidal cells in the cornu ammonis (CA) 1 and CA3 regions of the hippocampus which are responsible for memory encoding. This work demonstrated the potential for minimally invasive polymer-based neural probe arrays for multi-region recording in deep brain structures.
Collapse
Affiliation(s)
- Xuechun Wang
- Biomedical Engineering Department, University of Southern California, Los Angeles, CA 90089 USA
| | | | - Huijing Xu
- Biomedical Engineering Department, University of Southern California, Los Angeles, CA 90089 USA
| | | | - Aziliz Lecomte
- Fondazione Istituto Italiano di Technologia, 16163 Genova, Italy
| | - Kee Scholten
- Biomedical Engineering Department, University of Southern California, Los Angeles, CA 90089 USA
| | - Dong Song
- Biomedical Engineering Department, University of Southern California, Los Angeles, CA 90089 USA
| | - Ellis Meng
- Biomedical Engineering and Electrical and Computer Engineering Department, University of Southern California, Los Angeles, CA 90089 USA
| |
Collapse
|
14
|
Arafat MA, Rubin LN, Jefferys JGR, Irazoqui PP. A Method of Flexible Micro-Wire Electrode Insertion in Rodent for Chronic Neural Recording and a Device for Electrode Insertion. IEEE Trans Neural Syst Rehabil Eng 2019; 27:1724-1731. [DOI: 10.1109/tnsre.2019.2932032] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
15
|
Rezaei S, Xu Y, Pang SW. Control of neural probe shank flexibility by fluidic pressure in embedded microchannel using PDMS/PI hybrid substrate. PLoS One 2019; 14:e0220258. [PMID: 31339963 DOI: 10.1371/journal.pone.0220258] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 07/11/2019] [Indexed: 11/19/2022] Open
Abstract
Implantable neural probes are widely used to record and stimulate neural activities. These probes should be stiff enough for insertion. However, it should also be flexible to minimize tissue damage after insertion. Therefore, having dynamic control of the neural probe shank flexibility will be useful. For the first time, we have successfully fabricated flexible neural probes with embedded microfluidic channels for dynamic control of neural probe stiffness by controlling fluidic pressure in the channels. The present hybrid neural probes consisted of polydimethylsiloxane (PDMS) and polyimide (PI) layers could provide the required stiffness for insertion and flexibility during operation. The PDMS channels were fabricated by reversal imprint using a silicon mold and bonded to a PI layer to form the embedded channels in the neural probe. The probe shape was patterned using an oxygen plasma generated by an inductively coupled plasma etching system. The critical buckling force of PDMS/PI neural probes could be tuned from 0.25-1.25 mN depending on the applied fluidic pressure in the microchannels and these probes were successfully inserted into a 0.6% agarose gel that mimicked the stiffness of the brain tissue. Polymer-based neural probes are typically more flexible than conventional metal wire-based probes, and they could potentially provide less tissue damage after implantation.
Collapse
|
16
|
Vafaiee M, Vossoughi M, Mohammadpour R, Sasanpour P. Gold-Plated Electrode with High Scratch Strength for Electrophysiological Recordings. Sci Rep 2019; 9:2985. [PMID: 30814648 DOI: 10.1038/s41598-019-39138-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 01/18/2019] [Indexed: 11/08/2022] Open
Abstract
Multi electrode arrays (MEA) have been exploited in different electrophysiological applications. In neurological applications, MEAs are the vital interfaces between neurons and the electronic circuits with dual role; transmitting electric signal to the neurons and converting neural activity to the electric signal. Since the performance of the electrodes has a direct effect on the quality of the recorded neuronal signal, as well as the stimulation, the true choice of electrode material for MEA is crucial. Gold is one of the best candidates for fabrication of MEAs due to its high electrical conductivity, biocompatibility and good chemical stability. However, noble metals such as gold do not adhere well to the glass substrate. Consequently while exposing to the water, gold films are damaged, which impose limitations in the exploiting of gold thin films as the electrode. In this paper, a simple and cost effective method for the fabrication of gold electrode arrays is proposed. Using various mechanical (adhesion test and scratch strength), morphological (AFM and SEM) and electrochemical methods, the fabricated electrodes are characterized. The results show that the fabricated electrode arrays have significantly high scratch strength and stability within the aqueous medium. In addition, the electrical properties of the electrodes have been improved. The proposed electrodes have the potential to be exploited in other applications including electronics, electrochemistry, and biosensors.
Collapse
|
17
|
Seo KJ, Artoni P, Qiang Y, Zhong Y, Han X, Shi Z, Yao W, Fagiolini M, Fang H. Transparent, Flexible, Penetrating Microelectrode Arrays with Capabilities of Single-Unit Electrophysiology. ACTA ACUST UNITED AC 2019; 3:e1800276. [PMID: 32627399 DOI: 10.1002/adbi.201800276] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 12/08/2018] [Indexed: 01/08/2023]
Abstract
Accurately mapping neuronal activity across brain networks is critical to understand behaviors, yet it is very challenging due to the need of tools with both high spatial and temporal resolutions. Here, penetrating arrays of flexible microelectrodes made of low-impedance nanomeshes are presented, which are capable of recording single-unit electrophysiological neuronal activity and at the same time, transparent, allowing to bridge electrical and optical brain mapping modalities. These 32 transparent penetrating electrodes with site area, 225 µm2 , have a low impedance of ≈149 kΩ at 1 kHz, an adequate charge injection limit of ≈0.76 mC cm-2 , and up to 100% yield. Mechanical bending tests reveal that the array is robust up to 1000 bending cycles, and its high transmittance of 67% at 550 nm makes it suitable for combining with various optical methods. A temporary stiffening using polyethylene glycol allows the penetrating nanomesh arrays to be inserted into the brain minimally invasively, with in vivo validation of recordings of spontaneous and evoked single-unit activity of neurons across layers of the mouse visual cortex. Together, these results establish a novel neurotechnology-transparent, flexible, penetrating microelectrode arrays-which possesses great potential for brain research.
Collapse
Affiliation(s)
- Kyung Jin Seo
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA
| | - Pietro Artoni
- Center for Life Science, Boston Children's Hospital, Boston, MA, 02115, USA
| | - Yi Qiang
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA
| | - Yiding Zhong
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA
| | - Xun Han
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA
| | - Zhan Shi
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA
| | - Wenhao Yao
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA
| | - Michela Fagiolini
- Center for Life Science, Boston Children's Hospital, Boston, MA, 02115, USA
| | - Hui Fang
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, 02115, USA.,Department of Bioengineering, Northeastern University, Boston, MA, 02115, USA.,Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA, 02115, USA
| |
Collapse
|
18
|
Kim JH, Lee GH, Kim S, Chung HW, Lee JH, Lee SM, Kang CY, Lee S. Flexible deep brain neural probe for localized stimulation and detection with metal guide. Biosens Bioelectron 2018; 117:436-43. [DOI: 10.1016/j.bios.2018.06.035] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 06/07/2018] [Accepted: 06/19/2018] [Indexed: 01/31/2023]
|
19
|
Deku F, Frewin CL, Stiller A, Cohen Y, Aqeel S, Joshi-Imre A, Black B, Gardner TJ, Pancrazio JJ, Cogan SF. Amorphous Silicon Carbide Platform for Next Generation Penetrating Neural Interface Designs. Micromachines (Basel) 2018; 9:E480. [PMID: 30424413 PMCID: PMC6215182 DOI: 10.3390/mi9100480] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 09/09/2018] [Accepted: 09/17/2018] [Indexed: 11/16/2022]
Abstract
Microelectrode arrays that consistently and reliably record and stimulate neural activity under conditions of chronic implantation have so far eluded the neural interface community due to failures attributed to both biotic and abiotic mechanisms. Arrays with transverse dimensions of 10 µm or below are thought to minimize the inflammatory response; however, the reduction of implant thickness also decreases buckling thresholds for materials with low Young's modulus. While these issues have been overcome using stiffer, thicker materials as transport shuttles during implantation, the acute damage from the use of shuttles may generate many other biotic complications. Amorphous silicon carbide (a-SiC) provides excellent electrical insulation and a large Young's modulus, allowing the fabrication of ultrasmall arrays with increased resistance to buckling. Prototype a-SiC intracortical implants were fabricated containing 8 - 16 single shanks which had critical thicknesses of either 4 µm or 6 µm. The 6 µm thick a-SiC shanks could penetrate rat cortex without an insertion aid. Single unit recordings from SIROF-coated arrays implanted without any structural support are presented. This work demonstrates that a-SiC can provide an excellent mechanical platform for devices that penetrate cortical tissue while maintaining a critical thickness less than 10 µm.
Collapse
Affiliation(s)
- Felix Deku
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Christopher L Frewin
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Allison Stiller
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Yarden Cohen
- Department of Biology and Biomedical Engineering, Boston University, Boston, MA 02215, USA.
| | - Saher Aqeel
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Alexandra Joshi-Imre
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Bryan Black
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Timothy J Gardner
- Department of Biology and Biomedical Engineering, Boston University, Boston, MA 02215, USA.
| | - Joseph J Pancrazio
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| | - Stuart F Cogan
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
| |
Collapse
|
20
|
Pas J, Rutz AL, Quilichini PP, Slézia A, Ghestem A, Kaszas A, Donahue MJ, Curto VF, O’Connor RP, Bernard C, Williamson A, Malliaras GG. A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes. J Neural Eng 2018; 15:065001. [DOI: 10.1088/1741-2552/aadc1d] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
21
|
|
22
|
Xu H, Hirschberg AW, Scholten K, Berger TW, Song D, Meng E. Acute in vivo testing of a conformal polymer microelectrode array for multi-region hippocampal recordings. J Neural Eng 2018; 15:016017. [PMID: 29044049 PMCID: PMC5792195 DOI: 10.1088/1741-2552/aa9451] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The success of a cortical prosthetic device relies upon its ability to attain resolvable spikes from many neurons in particular neural networks over long periods of time. Traditionally, lifetimes of neural recordings are greatly limited by the body's immune response against the foreign implant which causes neuronal death and glial scarring. This immune reaction is posited to be exacerbated by micromotion between the implant, which is often rigid, and the surrounding, soft brain tissue, and attenuates the quality of recordings over time. APPROACH In an attempt to minimize the foreign body response to a penetrating neural array that records from multiple brain regions, Parylene C, a flexible, biocompatible polymer was used as the substrate material for a functional, proof-of-concept neural array with a reduced elastic modulus. This probe array was designed and fabricated to have 64 electrodes positioned to match the anatomy of the rat hippocampus and allow for simultaneous recordings between two cell-body layers of interest. A dissolvable brace was used for deep-brain penetration of the flexible array. MAIN RESULTS Arrays were electrochemically characterized at the benchtop, and a novel insertion technique that restricts acute insertion injury enabled accurate target placement of four, bare, flexible arrays to greater than 4 mm deep into the rat brain. Arrays were tested acutely and in vivo recordings taken intra-operatively reveal spikes in both targeted regions of the hippocampus with spike amplitudes and noise levels similar to those recorded with microwires. Histological staining of a sham array implanted for one month reveals limited astrocytic scarring and neuronal death around the implant. SIGNIFICANCE This work represents one of the first examples of a penetrating polymer probe array that records from individual neurons in structures that lie deep within the brain.
Collapse
Affiliation(s)
- Huijing Xu
- Department of Biomedical Engineering, Center for Neural Engineering, University of Southern California, Los Angeles, CA 90089-1111, United States of America
| | | | | | | | | | | |
Collapse
|
23
|
Shoffstall A, Capadona JR. Prospects for a Robust Cortical Recording Interface. Neuromodulation 2018. [DOI: 10.1016/b978-0-12-805353-9.00028-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
24
|
Qureshi NK, Naseer N, Noori FM, Nazeer H, Khan RA, Saleem S. Enhancing Classification Performance of Functional Near-Infrared Spectroscopy- Brain-Computer Interface Using Adaptive Estimation of General Linear Model Coefficients. Front Neurorobot 2017; 11:33. [PMID: 28769781 PMCID: PMC5512010 DOI: 10.3389/fnbot.2017.00033] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 06/22/2017] [Indexed: 11/20/2022] Open
Abstract
In this paper, a novel methodology for enhanced classification of functional near-infrared spectroscopy (fNIRS) signals utilizable in a two-class [motor imagery (MI) and rest; mental rotation (MR) and rest] brain–computer interface (BCI) is presented. First, fNIRS signals corresponding to MI and MR are acquired from the motor and prefrontal cortex, respectively, afterward, filtered to remove physiological noises. Then, the signals are modeled using the general linear model, the coefficients of which are adaptively estimated using the least squares technique. Subsequently, multiple feature combinations of estimated coefficients were used for classification. The best classification accuracies achieved for five subjects, for MI versus rest are 79.5, 83.7, 82.6, 81.4, and 84.1% whereas those for MR versus rest are 85.5, 85.2, 87.8, 83.7, and 84.8%, respectively, using support vector machine. These results are compared with the best classification accuracies obtained using the conventional hemodynamic response. By means of the proposed methodology, the average classification accuracy obtained was significantly higher (p < 0.05). These results serve to demonstrate the feasibility of developing a high-classification-performance fNIRS-BCI.
Collapse
Affiliation(s)
| | - Noman Naseer
- Department of Mechatronics Engineering, Air University, Islamabad, Pakistan
| | - Farzan Majeed Noori
- Department of Mechatronics Engineering, Air University, Islamabad, Pakistan.,Department of Electrical and Computer Engineering, Institute of Systems and Robotics, University of Coimbra, Coimbra, Portugal
| | - Hammad Nazeer
- Department of Mechatronics Engineering, Air University, Islamabad, Pakistan
| | - Rayyan Azam Khan
- Department of Mechatronics Engineering, Air University, Islamabad, Pakistan
| | - Sajid Saleem
- Faculty of Engineering and Computer Sciences, National University of Modern Languages, Islamabad, Pakistan
| |
Collapse
|
25
|
Lee HC, Ejserholm F, Gaire J, Currlin S, Schouenborg J, Wallman L, Bengtsson M, Park K, Otto KJ. Histological evaluation of flexible neural implants; flexibility limit for reducing the tissue response? J Neural Eng 2017; 14:036026. [PMID: 28470152 DOI: 10.1088/1741-2552/aa68f0] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE Flexible neural probes are hypothesized to reduce the chronic foreign body response (FBR) mainly by reducing the strain-stress caused by an interplay between the tethered probe and the brain's micromotion. However, a large discrepancy of Young's modulus still exists (3-6 orders of magnitude) between the flexible probes and the brain tissue. This raises the question of whether we need to bridge this gap; would increasing the probe flexibility proportionally reduce the FBR? APPROACH Using novel off-stoichiometry thiol-enes-epoxy (OSTE+) polymer probes developed in our previous work, we quantitatively evaluated the FBR to four types of probes with different softness: silicon (~150 GPa), polyimide (1.5 GPa), OSTE+Hard (300 MPa), and OSTE+Soft (6 MPa). MAIN RESULTS We observed a significant reduction in the fluorescence intensity of biomarkers for activated microglia/macrophages and blood-brain barrier (BBB) leakiness around the three soft polymer probes compared to the silicon probe, both at 4 weeks and 8 weeks post-implantation. However, we did not observe any consistent differences in the biomarkers among the polymer probes. SIGNIFICANCE The results suggest that the mechanical compliance of neural probes can mediate the degree of FBR, but its impact diminishes after a hypothetical threshold level. This infers that resolving the mechanical mismatch alone has a limited effect on improving the lifetime of neural implants.
Collapse
Affiliation(s)
- Heui Chang Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States of America. J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Noori FM, Naseer N, Qureshi NK, Nazeer H, Khan RA. Optimal feature selection from fNIRS signals using genetic algorithms for BCI. Neurosci Lett 2017; 647:61-6. [DOI: 10.1016/j.neulet.2017.03.013] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 03/09/2017] [Accepted: 03/10/2017] [Indexed: 11/18/2022]
|
27
|
Simon DM, Charkhkar H, St. John C, Rajendran S, Kang T, Reit R, Arreaga-Salas D, McHail DG, Knaack GL, Sloan A, Grasse D, Dumas TC, Rennaker RL, Pancrazio JJ, Voit WE. Design and demonstration of an intracortical probe technology with tunable modulus. J Biomed Mater Res A 2017; 105:159-168. [PMID: 27615364 PMCID: PMC9934867 DOI: 10.1002/jbm.a.35896] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2016] [Revised: 07/22/2016] [Accepted: 09/07/2016] [Indexed: 01/06/2023]
Abstract
Intracortical probe technology, consisting of arrays of microelectrodes, offers a means of recording the bioelectrical activity from neural tissue. A major limitation of existing intracortical probe technology pertains to limited lifetime of 6 months to a year of recording after implantation. A major contributor to device failure is widely believed to be the interfacial mechanical mismatch of conventional stiff intracortical devices and the surrounding brain tissue. We describe the design, development, and demonstration of a novel functional intracortical probe technology that has a tunable Young's modulus from ∼2 GPa to ∼50 MPa. This technology leverages advances in dynamically softening materials, specifically thiol-ene/acrylate thermoset polymers, which exhibit minimal swelling of < 3% weight upon softening in vitro. We demonstrate that a shape memory polymer-based multichannel intracortical probe can be fabricated, that the mechanical properties are stable for at least 2 months and that the device is capable of single unit recordings for durations up to 77 days in vivo. This novel technology, which is amenable to processes suitable for manufacturing via standard semiconductor fabrication techniques, offers the capability of softening in vivo to reduce the tissue-device modulus mismatch to ultimately improve long term viability of neural recordings. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 159-168, 2017.
Collapse
Affiliation(s)
- Dustin M. Simon
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Hamid Charkhkar
- Department of Electrical and Computer Engineering, George Mason University, Fairfax, Virginia 22030
| | - Conan St. John
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Sakthi Rajendran
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Tong Kang
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Radu Reit
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - David Arreaga-Salas
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Daniel G. McHail
- Department of Molecular Neuroscience, The Krasnow Institute for Advanced Study, George Mason University, Fairfax, Virginia 22030
| | - Gretchen L. Knaack
- Department of Molecular Neuroscience, The Krasnow Institute for Advanced Study, George Mason University, Fairfax, Virginia 22030
| | - Andrew Sloan
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Dane Grasse
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Theodore C. Dumas
- Department of Molecular Neuroscience, The Krasnow Institute for Advanced Study, George Mason University, Fairfax, Virginia 22030
| | - Robert L. Rennaker
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| | - Joseph J. Pancrazio
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030,Department of Bioengineering, George Mason University, Fairfax, Virginia 22030
| | - Walter E. Voit
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, Texas 75030,Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75030
| |
Collapse
|
28
|
Khilwani R, Gilgunn PJ, Kozai TDY, Ong XC, Korkmaz E, Gunalan PK, Cui XT, Fedder GK, Ozdoganlar OB. Ultra-miniature ultra-compliant neural probes with dissolvable delivery needles: design, fabrication and characterization. Biomed Microdevices 2016; 18:97. [DOI: 10.1007/s10544-016-0125-4] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
29
|
Weltman A, Yoo J, Meng E. Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication. Micromachines (Basel) 2016; 7:E180. [PMID: 30404353 DOI: 10.3390/mi7100180] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Accepted: 09/19/2016] [Indexed: 12/13/2022]
Abstract
The acquisition of high-fidelity, long-term neural recordings in vivo is critically important to advance neuroscience and brain⁻machine interfaces. For decades, rigid materials such as metal microwires and micromachined silicon shanks were used as invasive electrophysiological interfaces to neurons, providing either single or multiple electrode recording sites. Extensive research has revealed that such rigid interfaces suffer from gradual recording quality degradation, in part stemming from tissue damage and the ensuing immune response arising from mechanical mismatch between the probe and brain. The development of "soft" neural probes constructed from polymer shanks has been enabled by advancements in microfabrication; this alternative has the potential to mitigate mismatch-related side effects and thus improve the quality of recordings. This review examines soft neural probe materials and their associated microfabrication techniques, the resulting soft neural probes, and their implementation including custom implantation and electrical packaging strategies. The use of soft materials necessitates careful consideration of surgical placement, often requiring the use of additional surgical shuttles or biodegradable coatings that impart temporary stiffness. Investigation of surgical implantation mechanics and histological evidence to support the use of soft probes will be presented. The review concludes with a critical discussion of the remaining technical challenges and future outlook.
Collapse
|
30
|
Naseer N, Qureshi NK, Noori FM, Hong KS. Analysis of Different Classification Techniques for Two-Class Functional Near-Infrared Spectroscopy-Based Brain-Computer Interface. Comput Intell Neurosci 2016; 2016:5480760. [PMID: 27725827 DOI: 10.1155/2016/5480760] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 05/27/2016] [Accepted: 06/16/2016] [Indexed: 12/14/2022]
Abstract
We analyse and compare the classification accuracies of six different classifiers for a two-class mental task (mental arithmetic and rest) using functional near-infrared spectroscopy (fNIRS) signals. The signals of the mental arithmetic and rest tasks from the prefrontal cortex region of the brain for seven healthy subjects were acquired using a multichannel continuous-wave imaging system. After removal of the physiological noises, six features were extracted from the oxygenated hemoglobin (HbO) signals. Two- and three-dimensional combinations of those features were used for classification of mental tasks. In the classification, six different modalities, linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), k-nearest neighbour (kNN), the Naïve Bayes approach, support vector machine (SVM), and artificial neural networks (ANN), were utilized. With these classifiers, the average classification accuracies among the seven subjects for the 2- and 3-dimensional combinations of features were 71.6, 90.0, 69.7, 89.8, 89.5, and 91.4% and 79.6, 95.2, 64.5, 94.8, 95.2, and 96.3%, respectively. ANN showed the maximum classification accuracies: 91.4 and 96.3%. In order to validate the results, a statistical significance test was performed, which confirmed that the p values were statistically significant relative to all of the other classifiers (p < 0.005) using HbO signals.
Collapse
|
31
|
Marshall SP, Patel PR, Shih AJ, Chestek CA. Effects of geometry and material on the insertion of very small neural electrode. Annu Int Conf IEEE Eng Med Biol Soc 2016; 2016:2784-2788. [PMID: 28268896 DOI: 10.1109/embc.2016.7591308] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
For neural probes to be used chronically for years in the human body, they must provoke minimal scarring. Recently, a number of groups have reported substantially reduced scar tissue using cellular scale electrodes below 15 μm in size. This size scale is accessible to manufacturing techniques, but can be very difficult to insert in the brain for most common electrode materials. In this study, we explore the design space available to cellular scale electrodes that will self-insert into the brain. First a mathematical model is developed using beam buckling equations for different materials and geometries. Buckling mode was found to be one fixed and one hinged end resulting in a mode conditional constant of, n, 2.045. Model predicts insertion success between 90-100% for a 6.8 μm diameter electrode and was used to approximate applied force as 750 μN which is close to reference data of 780 μN [1]. Second, we developed a PVC phantom that mimics the brain's elastic modulus. This phantom was matched to insertion success data obtained from carbon fiber arrays [1]. Overall, these results enable studies to be conducted on other proposed cellular scale electrodes prior to animal testing or large scale fabrication.
Collapse
|
32
|
Naseer N, Noori FM, Qureshi NK, Hong KS. Determining Optimal Feature-Combination for LDA Classification of Functional Near-Infrared Spectroscopy Signals in Brain-Computer Interface Application. Front Hum Neurosci 2016; 10:237. [PMID: 27252637 PMCID: PMC4879140 DOI: 10.3389/fnhum.2016.00237] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 05/05/2016] [Indexed: 11/13/2022] Open
Abstract
In this study, we determine the optimal feature-combination for classification of functional near-infrared spectroscopy (fNIRS) signals with the best accuracies for development of a two-class brain-computer interface (BCI). Using a multi-channel continuous-wave imaging system, mental arithmetic signals are acquired from the prefrontal cortex of seven healthy subjects. After removing physiological noises, six oxygenated and deoxygenated hemoglobin (HbO and HbR) features-mean, slope, variance, peak, skewness and kurtosis-are calculated. All possible 2- and 3-feature combinations of the calculated features are then used to classify mental arithmetic vs. rest using linear discriminant analysis (LDA). It is found that the combinations containing mean and peak values yielded significantly higher (p < 0.05) classification accuracies for both HbO and HbR than did all of the other combinations, across all of the subjects. These results demonstrate the feasibility of achieving high classification accuracies using mean and peak values of HbO and HbR as features for classification of mental arithmetic vs. rest for a two-class BCI.
Collapse
Affiliation(s)
- Noman Naseer
- Department of Mechatronics Engineering, Air University Islamabad, Pakistan
| | - Farzan M Noori
- Department of Mechatronics Engineering, Air University Islamabad, Pakistan
| | - Nauman K Qureshi
- Department of Mechatronics Engineering, Air University Islamabad, Pakistan
| | - Keum-Shik Hong
- Department of Cogno-Mechatronics, School of Mechanical Engineering, Pusan National University Busan, Korea
| |
Collapse
|
33
|
Knothe Tate ML, Detamore M, Capadona JR, Woolley A, Knothe U. Engineering and commercialization of human-device interfaces, from bone to brain. Biomaterials 2016; 95:35-46. [PMID: 27108404 DOI: 10.1016/j.biomaterials.2016.03.038] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 03/16/2016] [Accepted: 03/28/2016] [Indexed: 12/16/2022]
Abstract
Cutting edge developments in engineering of tissues, implants and devices allow for guidance and control of specific physiological structure-function relationships. Yet the engineering of functionally appropriate human-device interfaces represents an intractable challenge in the field. This leading opinion review outlines a set of current approaches as well as hurdles to design of interfaces that modulate transfer of information, i.a. forces, electrical potentials, chemical gradients and haptotactic paths, between endogenous and engineered body parts or tissues. The compendium is designed to bridge across currently separated disciplines by highlighting specific commonalities between seemingly disparate systems, e.g. musculoskeletal and nervous systems. We focus on specific examples from our own laboratories, demonstrating that the seemingly disparate musculoskeletal and nervous systems share common paradigms which can be harnessed to inspire innovative interface design solutions. Functional barrier interfaces that control molecular and biophysical traffic between tissue compartments of joints are addressed in an example of the knee. Furthermore, we describe the engineering of gradients for interfaces between endogenous and engineered tissues as well as between electrodes that physically and electrochemically couple the nervous and musculoskeletal systems. Finally, to promote translation of newly developed technologies into products, protocols, and treatments that benefit the patients who need them most, regulatory and technical challenges and opportunities are addressed on hand from an example of an implant cum delivery device that can be used to heal soft and hard tissues, from brain to bone.
Collapse
|
34
|
Ejserholm F, Stegmayr J, Bauer P, Johansson F, Wallman L, Bengtsson M, Oredsson S. Biocompatibility of a polymer based on Off-Stoichiometry Thiol-Enes + Epoxy (OSTE+) for neural implants. Biomater Res 2015; 19:19. [PMID: 26396744 PMCID: PMC4578262 DOI: 10.1186/s40824-015-0041-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 09/04/2015] [Indexed: 11/10/2022] Open
Abstract
Background The flexibility of implantable neural probes has increased during the last 10 years, starting with stiff materials such as silicone to more flexible materials like polyimide. We have developed a novel polymer based on Off-Stoichiometry Thiol-Enes + Epoxy (OSTE+, consisting of a thiol, two allyls, an epoxy resin and two initiators), which is up to 100 times more flexible than polyimide. Since a flexible neural probe should be more biocompatible than a stiff probe, an OSTE+ probe should be more biocompatible than one composed of a more rigid material. We have investigated the toxicity of OSTE+ as well as of OSTE+ that had been incubated in water for a week (OSTE+H2O) using MTT assays with mouse L929 fibroblasts. We found that OSTE+ showed cytotoxicity, but OSTE+H2O did not. Extracts were analyzed using LC-MS and GC-MS in order to identify leaked chemicals. Results Most constituents were found in extracts of OSTE+, whereas only initiators were found in OSTE+H2O extracts. The detected levels of each chemical found in the LC-MS and the GC-MS analysis were below the toxicity level when compared to MTT assays of all the individual chemicals, except for one of the initiators that had an IC50 value close to the detected levels. Conclusion Our notion is that the toxicity of OSTE+ was caused by one of the initiators, by impurities in the constituents or by synergistic effects of low doses of leaked chemicals. However, our conclusion is that if OSTE+ is incubated for one week in water, OSTE+ is not cytotoxic and suitable for further in vivo studies.
Collapse
Affiliation(s)
- Fredrik Ejserholm
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00 Sweden ; NeuroNano Research Centre, Lund University, Medicon Village, Scheelevägen 8, Lund, 223 81 Sweden
| | - John Stegmayr
- Department of Laboratory Medicine, Lund University, Box 118, Lund, 221 00 Sweden ; Department of Biology, Lund University, Box 118, Lund, 221 00 Sweden
| | - Patrik Bauer
- Department of Biology, Lund University, Box 118, Lund, 221 00 Sweden
| | - Fredrik Johansson
- NeuroNano Research Centre, Lund University, Medicon Village, Scheelevägen 8, Lund, 223 81 Sweden ; Department of Biology, Lund University, Box 118, Lund, 221 00 Sweden
| | - Lars Wallman
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00 Sweden ; NeuroNano Research Centre, Lund University, Medicon Village, Scheelevägen 8, Lund, 223 81 Sweden
| | - Martin Bengtsson
- Department of Biomedical Engineering, Lund University, Box 118, Lund, 221 00 Sweden ; NeuroNano Research Centre, Lund University, Medicon Village, Scheelevägen 8, Lund, 223 81 Sweden
| | - Stina Oredsson
- Department of Biology, Lund University, Box 118, Lund, 221 00 Sweden
| |
Collapse
|
35
|
Kolarcik CL, Luebben SD, Sapp SA, Hanner J, Snyder N, Kozai TDY, Chang E, Nabity JA, Nabity ST, Lagenaur CF, Cui XT. Elastomeric and soft conducting microwires for implantable neural interfaces. Soft Matter 2015; 11:4847-61. [PMID: 25993261 PMCID: PMC4466039 DOI: 10.1039/c5sm00174a] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young's modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young's modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications.
Collapse
Affiliation(s)
- Christi L Kolarcik
- Department of Bioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Abstract
OBJECTIVE The objective of this research is to characterize the mechanical interactions of (1) soft, compliant and (2) non-compliant implants with the surrounding brain tissue in a rodent brain. Understanding such interactions will enable the engineering of novel materials that will improve stability and reliability of brain implants. APPROACH Acute force measurements were made using a load cell in n = 3 live rats, each with 4 craniotomies. Using an indentation method, brain tissue was tested for changes in force using established protocols. A total of 4 non-compliant, bare silicon microshanks, 3 non-compliant polyvinyl acetate (PVAc)-coated silicon microshanks, and 6 compliant, nanocomposite microshanks were tested. Stress values were calculated by dividing the force by surface area and strain was estimated using a linear stress-strain relationship. Micromotion effects from breathing and vascular pulsatility on tissue stress were estimated from a 5 s interval of steady-state measurements. Viscoelastic properties were estimated using a second-order Prony series expansion of stress-displacement curves for each shank. MAIN RESULTS The distribution of strain values imposed on brain tissue for both compliant nanocomposite microshanks and PVAc-coated, non-compliant silicon microshanks were significantly lower compared to non-compliant bare silicon shanks. Interestingly, step-indentation experiments also showed that compliant, nanocomposite materials significantly decreased stress relaxation rates in the brain tissue at the interface (p < 0.05) compared to non-compliant silicon and PVAc-coated silicon materials. Furthermore, both PVAc-coated non-compliant silicon and compliant nanocomposite shanks showed significantly reduced (by 4-5 fold) stresses due to tissue micromotion at the interface. SIGNIFICANCE The results of this study showed that soft, adaptive materials reduce strains and strain rates and micromotion induced stresses in the surrounding brain tissue. Understanding the material behavior at the site of tissue contact will help to improve neural implant design.
Collapse
Affiliation(s)
- Arati Sridharan
- School of Biological & Health Systems Engineering, Ira A. Fulton School of Engineering, Arizona State University, Tempe, AZ 85287, USA
| | | | | | | |
Collapse
|
37
|
Hussain AM, Lizardo EB, Torres Sevilla GA, Nassar JM, Hussain MM. Ultrastretchable and flexible copper interconnect-based smart patch for adaptive thermotherapy. Adv Healthc Mater 2015; 4:665-73. [PMID: 25471473 DOI: 10.1002/adhm.201400647] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 11/12/2014] [Indexed: 12/23/2022]
Abstract
Unprecedented 800% stretchable, non-polymeric, widely used, low-cost, naturally rigid, metallic thin-film copper (Cu)-based flexible and non-invasive, spatially tunable, mobile thermal patch with wireless controllability, adaptability (tunes the amount of heat based on the temperature of the swollen portion), reusability, and affordability due to low-cost complementary metal oxide semiconductor (CMOS) compatible integration.
Collapse
Affiliation(s)
- Aftab M. Hussain
- Integrated Nanotechnology Laboratory; Computer Electrical Mathematical Science and Engineering Division; King Abdullah University of Science and Technology (KAUST); Thuwal Saudi Arabia
| | - Ernesto Byas Lizardo
- Integrated Nanotechnology Laboratory; Computer Electrical Mathematical Science and Engineering Division; King Abdullah University of Science and Technology (KAUST); Thuwal Saudi Arabia
| | - Galo A. Torres Sevilla
- Integrated Nanotechnology Laboratory; Computer Electrical Mathematical Science and Engineering Division; King Abdullah University of Science and Technology (KAUST); Thuwal Saudi Arabia
| | - Joanna M. Nassar
- Integrated Nanotechnology Laboratory; Computer Electrical Mathematical Science and Engineering Division; King Abdullah University of Science and Technology (KAUST); Thuwal Saudi Arabia
| | - Muhammad M. Hussain
- Integrated Nanotechnology Laboratory; Computer Electrical Mathematical Science and Engineering Division; King Abdullah University of Science and Technology (KAUST); Thuwal Saudi Arabia
| |
Collapse
|
38
|
Gunasekera B, Saxena T, Bellamkonda R, Karumbaiah L. Intracortical recording interfaces: current challenges to chronic recording function. ACS Chem Neurosci 2015; 6:68-83. [PMID: 25587704 DOI: 10.1021/cn5002864] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Brain Computer Interfaces (BCIs) offer significant hope to tetraplegic and paraplegic individuals. This technology relies on extracting and translating motor intent to facilitate control of a computer cursor or to enable fine control of an external assistive device such as a prosthetic limb. Intracortical recording interfaces (IRIs) are critical components of BCIs and consist of arrays of penetrating electrodes that are implanted into the motor cortex of the brain. These multielectrode arrays (MEAs) are responsible for recording and conducting neural signals from local ensembles of neurons in the motor cortex with the high speed and spatiotemporal resolution that is required for exercising control of external assistive prostheses. Recent design and technological innovations in the field have led to significant improvements in BCI function. However, long-term (chronic) BCI function is severely compromised by short-term (acute) IRI recording failure. In this review, we will discuss the design and function of current IRIs. We will also review a host of recent advances that contribute significantly to our overall understanding of the cellular and molecular events that lead to acute recording failure of these invasive implants. We will also present recent improvements to IRI design and provide insights into the futuristic design of more chronically functional IRIs.
Collapse
Affiliation(s)
- Bhagya Gunasekera
- Regenerative
Bioscience Center, ADS Complex, The University of Georgia, Athens, Georgia 30602-2771, United States
| | - Tarun Saxena
- Wallace
H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0535, United States
| | - Ravi Bellamkonda
- Wallace
H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0535, United States
| | - Lohitash Karumbaiah
- Regenerative
Bioscience Center, ADS Complex, The University of Georgia, Athens, Georgia 30602-2771, United States
| |
Collapse
|
39
|
Abstract
To ensure long-term consistent neural recordings, next-generation intracortical microelectrodes are being developed with an increased emphasis on reducing the neuro-inflammatory response. The increased emphasis stems from the improved understanding of the multifaceted role that inflammation may play in disrupting both biologic and abiologic components of the overall neural interface circuit. To combat neuro-inflammation and improve recording quality, the field is actively progressing from traditional inorganic materials towards approaches that either minimizes the microelectrode footprint or that incorporate compliant materials, bioactive molecules, conducting polymers or nanomaterials. However, the immune-privileged cortical tissue introduces an added complexity compared to other biomedical applications that remains to be fully understood. This review provides a comprehensive reflection on the current understanding of the key failure modes that may impact intracortical microelectrode performance. In addition, a detailed overview of the current status of various materials-based approaches that have gained interest for neural interfacing applications is presented, and key challenges that remain to be overcome are discussed. Finally, we present our vision on the future directions of materials-based treatments to improve intracortical microelectrodes for neural interfacing.
Collapse
Affiliation(s)
- Mehdi Jorfi
- Adolphe Merkle Institute, University of Fribourg, Rte de l'Ancienne Papeterie, CH-1723 Marly, Switzerland
| | | | | | | |
Collapse
|
40
|
David-Pur M, Bareket-Keren L, Beit-Yaakov G, Raz-Prag D, Hanein Y. All-carbon-nanotube flexible multi-electrode array for neuronal recording and stimulation. Biomed Microdevices 2014; 16:43-53. [PMID: 23974529 PMCID: PMC3921458 DOI: 10.1007/s10544-013-9804-6] [Citation(s) in RCA: 96] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Neuro-prosthetic devices aim to restore impaired function through artificial stimulation of the nervous system. A lingering technological bottleneck in this field is the realization of soft, micron sized electrodes capable of injecting enough charge to evoke localized neuronal activity without causing neither electrode nor tissue damage. Direct stimulation with micro electrodes will offer the high efficacy needed in applications such as cochlear and retinal implants. Here we present a new flexible neuronal micro electrode device, based entirely on carbon nanotube technology, where both the conducting traces and the stimulating electrodes consist of conducting carbon nanotube films embedded in a polymeric support. The use of carbon nanotubes bestows the electrodes flexibility and excellent electrochemical properties. As opposed to contemporary flexible neuronal electrodes, the technology presented here is both robust and the resulting stimulating electrodes are nearly purely capacitive. Recording and stimulation tests with chick retinas were used to validate the advantageous properties of the electrodes and demonstrate their suitability for high-efficacy neuronal stimulation applications.
Collapse
Affiliation(s)
- Moshe David-Pur
- School of Electrical Engineering, Tel-Aviv University, Tel-Aviv, 6997801, Israel
| | | | | | | | | |
Collapse
|
41
|
Aregueta-Robles UA, Woolley AJ, Poole-Warren LA, Lovell NH, Green RA. Organic electrode coatings for next-generation neural interfaces. Front Neuroeng 2014; 7:15. [PMID: 24904405 PMCID: PMC4034607 DOI: 10.3389/fneng.2014.00015] [Citation(s) in RCA: 136] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Accepted: 05/06/2014] [Indexed: 01/05/2023]
Abstract
Traditional neuronal interfaces utilize metallic electrodes which in recent years have reached a plateau in terms of the ability to provide safe stimulation at high resolution or rather with high densities of microelectrodes with improved spatial selectivity. To achieve higher resolution it has become clear that reducing the size of electrodes is required to enable higher electrode counts from the implant device. The limitations of interfacing electrodes including low charge injection limits, mechanical mismatch and foreign body response can be addressed through the use of organic electrode coatings which typically provide a softer, more roughened surface to enable both improved charge transfer and lower mechanical mismatch with neural tissue. Coating electrodes with conductive polymers or carbon nanotubes offers a substantial increase in charge transfer area compared to conventional platinum electrodes. These organic conductors provide safe electrical stimulation of tissue while avoiding undesirable chemical reactions and cell damage. However, the mechanical properties of conductive polymers are not ideal, as they are quite brittle. Hydrogel polymers present a versatile coating option for electrodes as they can be chemically modified to provide a soft and conductive scaffold. However, the in vivo chronic inflammatory response of these conductive hydrogels remains unknown. A more recent approach proposes tissue engineering the electrode interface through the use of encapsulated neurons within hydrogel coatings. This approach may provide a method for activating tissue at the cellular scale, however, several technological challenges must be addressed to demonstrate feasibility of this innovative idea. The review focuses on the various organic coatings which have been investigated to improve neural interface electrodes.
Collapse
Affiliation(s)
| | - Andrew J. Woolley
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
- School of Medicine, University of Western SydneySydney, NSW, Australia
| | - Laura A. Poole-Warren
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
| | - Nigel H. Lovell
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
| | - Rylie A. Green
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
| |
Collapse
|
42
|
Abstract
Light activation of neurons is a growing field with applications ranging from basic investigation of neuronal systems to the development of new therapeutic methods such as artificial retina. Many recent studies currently explore novel methods for optical stimulation with temporal and spatial precision. Novel materials in particular provide an opportunity to enhance contemporary approaches. Here we review recent advances towards light directed interfaces for neuronal stimulation, focusing on state-of-the-art nanoengineered devices. In particular, we highlight challenges and prospects towards improved retinal prostheses.
Collapse
Affiliation(s)
- Lilach Bareket-Keren
- School of Electrical Engineering, Tel-Aviv University, Tel-Aviv University, Tel-Aviv, Israel ; Tel-Aviv University Center for Nanoscience and Nanotechnology, Tel-Aviv University, Tel-Aviv, Israel
| | - Yael Hanein
- School of Electrical Engineering, Tel-Aviv University, Tel-Aviv University, Tel-Aviv, Israel ; Tel-Aviv University Center for Nanoscience and Nanotechnology, Tel-Aviv University, Tel-Aviv, Israel
| |
Collapse
|
43
|
Fattahi P, Yang G, Kim G, Abidian MR. A review of organic and inorganic biomaterials for neural interfaces. Adv Mater 2014; 26:1846-85. [PMID: 24677434 PMCID: PMC4373558 DOI: 10.1002/adma.201304496] [Citation(s) in RCA: 292] [Impact Index Per Article: 29.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 10/08/2013] [Indexed: 05/18/2023]
Abstract
Recent advances in nanotechnology have generated wide interest in applying nanomaterials for neural prostheses. An ideal neural interface should create seamless integration into the nervous system and performs reliably for long periods of time. As a result, many nanoscale materials not originally developed for neural interfaces become attractive candidates to detect neural signals and stimulate neurons. In this comprehensive review, an overview of state-of-the-art microelectrode technologies provided fi rst, with focus on the material properties of these microdevices. The advancements in electro active nanomaterials are then reviewed, including conducting polymers, carbon nanotubes, graphene, silicon nanowires, and hybrid organic-inorganic nanomaterials, for neural recording, stimulation, and growth. Finally, technical and scientific challenges are discussed regarding biocompatibility, mechanical mismatch, and electrical properties faced by these nanomaterials for the development of long-lasting functional neural interfaces.
Collapse
Affiliation(s)
- Pouria Fattahi
- Biomedical Engineering Department and Chemical Engineering Departments, Pennsylvania State University, University Park, PA, 16802, USA
| | - Guang Yang
- Biomedical Engineering Department, Pennsylvania State University, University Park, PA, 16802, USA
| | - Gloria Kim
- Biomedical Engineering Department, Pennsylvania State University, University Park, PA, 16802, USA
| | - Mohammad Reza Abidian
- Biomedical Engineering Department, Materials Science & Engineering Department, Chemical Engineering Department, Materials Research Institute, Huck Institutes of the Life Sciences, Pennsylvania State University, University Park, PA, 16802, USA
| |
Collapse
|
44
|
Hwang HJ, Lim JH, Kim DW, Im CH. Evaluation of various mental task combinations for near-infrared spectroscopy-based brain-computer interfaces. J Biomed Opt 2014; 19:77005. [PMID: 25036216 DOI: 10.1117/1.jbo.19.7.077005] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2014] [Accepted: 06/20/2014] [Indexed: 05/15/2023]
Abstract
A number of recent studies have demonstrated that near-infrared spectroscopy (NIRS) is a promisingneuroimaging modality for brain-computer interfaces (BCIs). So far, most NIRS-based BCI studies have focusedon enhancing the accuracy of the classification of different mental tasks. In the present study, we evaluated theperformances of a variety of mental task combinations in order to determine the mental task pairs that are bestsuited for customized NIRS-based BCIs. To this end, we recorded event-related hemodynamic responses whileseven participants performed eight different mental tasks. Classification accuracies were then estimated for allpossible pairs of the eight mental tasks (8C2 = 28). Based on this analysis, mental task combinations with relatively high classification accuracies frequently included the following three mental tasks: “mental multiplication,” “mental rotation,” and “right-hand motor imagery.” Specifically, mental task combinations consisting of two of these three mental tasks showed the highest mean classification accuracies. It is expected that our results will be a useful reference to reduce the time needed for preliminary tests when discovering individual-specific mental task combinations.
Collapse
Affiliation(s)
- Han-Jeong Hwang
- Hanyang University, Department of Biomedical Engineering, Seoul 133-791, Republic of KoreabBerlin Institute of Technology, Machine Learning Group, Marchstrasse 23, Berlin 10587, Germany
| | - Jeong-Hwan Lim
- Hanyang University, Department of Biomedical Engineering, Seoul 133-791, Republic of Korea
| | - Do-Won Kim
- Hanyang University, Department of Biomedical Engineering, Seoul 133-791, Republic of Korea
| | - Chang-Hwan Im
- Hanyang University, Department of Biomedical Engineering, Seoul 133-791, Republic of Korea
| |
Collapse
|
45
|
Abstract
We proposed a method of making a flexible depth-type neural probe using liquid crystal polymer. Conventional depth neural probes made of metal or silicon have the limitations of a single recording site per shank or the brittleness of the silicon substrate. To avoid these drawbacks, polymer-based depth neural probes have been developed with biocompatible polymers such as polyimides or parylenes. However, those have suffered from the difficulty of inserting the probes into brain tissues due to their high flexibility, requiring mechanical reinforcements. Herein, we report the first attempt to use a flexible material, liquid crystal polymer (LCP), as a substrate for a depth-type neural probe. The LCP-based probe offers a controllable stiffness vs. flexibility and compatibility with thin-film processes in addition to its inherent characteristics such as high reliability and biocompatibility. In the present study, an LCP neural probe was fabricated to have enough stiffness to penetrate the dura mater of rodent brains without a guide tool or additional reinforcement structures. A simultaneous multichannel neural recording was successfully achieved from the somatosensory motor cortex of the rodents. Immunohistochemistry showed that the electrodes could be inserted into the desired regions in the brain.
Collapse
Affiliation(s)
- Sung Eun Lee
- Department of Electrical Engineering and Computer Science, Inter-University Semiconductor Research Center, Seoul National University, Seoul, 151-744, Korea.
| | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Li C, Wu P, Hartings JA, Wu Z, Cheyuo C, Wang P, Ledoux D, Shutter LA, Ramaswamy BR, Ahn CH, Narayan RK. Micromachined lab-on-a-tube sensors for simultaneous brain temperature and cerebral blood flow measurements. Biomed Microdevices 2012; 14:759-68. [DOI: 10.1007/s10544-012-9646-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
47
|
Harris JP, Capadona JR, Miller RH, Healy BC, Shanmuganathan K, Rowan SJ, Weder C, Tyler DJ. Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies. J Neural Eng 2011; 8:066011. [PMID: 22049097 DOI: 10.1088/1741-2560/8/6/066011] [Citation(s) in RCA: 148] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The hypothesis is that the mechanical mismatch between brain tissue and microelectrodes influences the inflammatory response. Our unique, mechanically adaptive polymer nanocomposite enabled this study within the cerebral cortex of rats. The initial tensile storage modulus of 5 GPa decreases to 12 MPa within 15 min under physiological conditions. The response to the nanocomposite was compared to surface-matched, stiffer implants of traditional wires (411 GPa) coated with the identical polymer substrate and implanted on the contralateral side. Both implants were tethered. Fluorescent immunohistochemistry labeling examined neurons, intermediate filaments, macrophages, microglia and proteoglycans. We demonstrate, for the first time, a system that decouples the mechanical and surface chemistry components of the neural response. The neuronal nuclei density within 100 µm of the device at four weeks post-implantation was greater for the compliant nanocomposite compared to the stiff wire. At eight weeks post-implantation, the neuronal nuclei density around the nanocomposite was maintained, but the density around the wire recovered to match that of the nanocomposite. The glial scar response to the compliant nanocomposite was less vigorous than it was to the stiffer wire. The results suggest that mechanically associated factors such as proteoglycans and intermediate filaments are important modulators of the response of the compliant nanocomposite.
Collapse
Affiliation(s)
- J P Harris
- Department of Biomedical Engineering, CWRU, Cleveland, OH 44106, USA
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Harris JP, Hess AE, Rowan SJ, Weder C, Zorman CA, Tyler DJ, Capadona JR. In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes. J Neural Eng 2011; 8:046010. [PMID: 21654037 DOI: 10.1088/1741-2560/8/4/046010] [Citation(s) in RCA: 113] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We recently introduced a series of stimuli-responsive, mechanically adaptive polymer nanocomposites. Here, we report the first application of these bio-inspired materials as substrates for intracortical microelectrodes. Our hypothesis is that the ideal electrode should be initially stiff to facilitate minimal trauma during insertion into the cortex, yet become mechanically compliant to match the stiffness of the brain tissue and minimize forces exerted on the tissue, attenuating inflammation. Microprobes created from mechanically reinforced nanocomposites demonstrated a significant advantage compared to model microprobes composed of neat polymer only. The nanocomposite microprobes exhibit a higher storage modulus (E' = ~5 GPa) than the neat polymer microprobes (E' = ~2 GPa) and can sustain higher loads (~12 mN), facilitating penetration through the pia mater and insertion into the cerebral cortex of a rat. In contrast, the neat polymer microprobes mechanically failed under lower loads (~7 mN) before they were capable of insertion into cortical tissue. Further, we demonstrated the material's ability to morph while in the rat cortex to more closely match the mechanical properties of the cortical tissue. Nanocomposite microprobes that were implanted into the rat cortex for up to eight weeks demonstrated increased cell density at the microelectrode-tissue interface and a lack of tissue necrosis or excessive gliosis. This body of work introduces our nanocomposite-based microprobes as adaptive substrates for intracortical microelectrodes and potentially for other biomedical applications.
Collapse
Affiliation(s)
- J P Harris
- Department of Biomedical Engineering, CWRU, 2071 Martin Luther King Jr Drive, Wickenden Bldg, Cleveland, OH 44106, USA.
| | | | | | | | | | | | | |
Collapse
|
49
|
Abstract
Bioelectrodes for neural recording and neurostimulation are an integral component of a number of neuroprosthetic devices, including the commercially available cochlear implant, and developmental devices, such as the bionic eye and brain-machine interfaces. Current electrode designs limit the application of such devices owing to suboptimal material properties that lead to minimal interaction with the target neural tissue and the formation of fibrotic capsules. In designing an ideal bioelectrode, a number of design criteria must be considered with respect to physical, mechanical, electrical and biological properties. Conducting polymers have the potential to address the synergistic interaction of these properties and show promise as superior coatings for next-generation electrodes in implant devices.
Collapse
Affiliation(s)
- Laura Poole-Warren
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| | | | | | | |
Collapse
|