1
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
2
|
Abstract
INTRODUCTION This review critically examines the efficacy of dual-modular stems in primary total hip arthroplasty. Given the variability and non-comparability of certain femoral stem designs and stem-neck couplings, with some even being withdrawn from the market, this review offers an in-depth analysis of predominant implant performances. AREAS COVERED The paper explores a brief historical summary related to dual-modular stems, including the complications associated with their use, diagnostic tools for evaluation, analysis of both recalled and currently available models, as well as alternative therapeutic options. This information is pertinent for both clinical and research domains. EXPERT OPINION While dual-modular systems were initially touted to offer several advantages, the evidence substantiating these benefits has been ambiguous. Further, these systems introduce the risk of alternative complications. In specific cases involving patients with developmental hip dysplasia and certain proximal femoral deformities requiring complex reconstructions, dual-modular systems might be relevant. Nonetheless, the use of long interchangeable necks in patients with a body mass index above 30 kg/m2 is discouraged, and pairing a long varus-oriented neck with an extra-long femoral head should be avoided in all patients.
Collapse
Affiliation(s)
- Jan Zajc
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Samo K Fokter
- Clinical Department of Orthopedic Surgery, University Medical Center Maribor, Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Maribor, Slovenia
| |
Collapse
|
3
|
Wu Q, Chen B, Yu X, Wang Z, Sun Z, Duan J, Ding H, Wu W, Bao N, Zhao J. Bone and Soft Tissue Reaction to Co(II)/Cr(III) Ions Stimulation in a Murine Calvaria Model: A Pioneering in vivo Study. Acta Biomater 2023; 164:659-670. [PMID: 37003495 DOI: 10.1016/j.actbio.2023.03.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 03/16/2023] [Accepted: 03/24/2023] [Indexed: 04/03/2023]
Abstract
Metal ions released during wear and corrosion of the artificial knee/hip joints are considered to contribute to aseptic implant failure. However, there are few convincing in vivo studies that demonstrate the effects of metal ions on bone and soft tissue. This study examined the in vivo effects of Co(II)/Cr(III) ions on mouse calvaria and the supra-calvaria soft tissue in an original mouse model. With the implantation of a helmet-like structure, we set up a subcutaneous cavity on the calvaria in which Co(II) Chloride or Cr(III) Chloride solutions were administered respectively. A layer of interface membrane formed on the calvaria along with the implantation of the helmet. The administered Cr(III) ions accumulated in the interface membranes while Co(II) disseminated into the circulation. Accumulated Cr(III) and related products induced local massive macrophage infiltration and skewed the bone metabolic balance. At last, we revealed that lymphocyte aggregates, which are the pathologic hallmark of human periprosthetic tissue, could be caused by either Co(II) or Cr(III) stimulation. These in vivo results may shed light on the effects and pathogenic mechanism of the Co(II)/Cr(III) ions released from the joint prosthesis. STATEMENT OF SIGNIFICANCE: Macrophage infiltration and lymphocyte aggregates are hallmarks of human joint periprosthetic tissue. We chronically administered Co(II)/Cr(III) ions on mouse calvaria and reproduced these two histopathologic hallmarks on mouse tissue based on an implanted helmet-like structure. Our results reveal that Cr(III) ions are locally accumulated and are effective in inducing macrophage infiltration and they can be phagocytosed and stored. However, the lymphocytes aggregates could be induced by both Co(II), Cr(III) and other unspecific inflammatory stimuli.
Collapse
Affiliation(s)
- Qi Wu
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China
| | - Bin Chen
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China
| | - Xin Yu
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China
| | - Zhen Wang
- Nanjing Medical University, 101 Longmian Avenue, Nanjing 211166, China
| | - Zhongyang Sun
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China
| | - Jiahua Duan
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China
| | - Hao Ding
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China
| | - Weiwei Wu
- Department of Vascular Surgery, Beijing Tsinghua Changgung Hospital, Tsinghua University Medical Center, Beijing 102218, China
| | - Nirong Bao
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China.
| | - Jianning Zhao
- Department of Orthopaedics, Affiliated Jinling Hospital, Medical School of Nanjing University, 305 Zhongshandonglu Road, Nanjing 210002, China.
| |
Collapse
|
4
|
Eltit F, Mohammad N, Medina I, Haegert A, Duncan CP, Garbuz DS, Greidanus NV, Masri BA, Ng TL, Wang R, Cox ME. Perivascular lymphocytic aggregates in hip prosthesis-associated adverse local tissue reactions demonstrate Th1 and Th2 activity and exhausted CD8 + cell responses. J Orthop Res 2021; 39:2581-2594. [PMID: 33506972 DOI: 10.1002/jor.24998] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 01/19/2021] [Accepted: 01/24/2021] [Indexed: 02/04/2023]
Abstract
Hip implants are a successful solution for osteoarthritis; however, some individuals with metal-on-metal (MoM) and metal-on-polyethylene (MoP) prosthetics develop adverse local tissue reactions (ALTRs). While MoM and MoP ALTRs are presumed to be delayed hypersensitivity reactions to corrosion products, MoM- and MoP-associated ALTRs present with different histological characteristics. We compared MoM- and MoP-associated ALTRs histopathology with cobalt and chromium levels in serum and synovial fluid. We analyzed the gene expression levels of leukocyte aggregates and synovial fluid chemokines/cytokines to resolve potential pathophysiologic differences. In addition, we classified ALTRs from 79 patients according to their leukocyte infiltrates as macrophage-dominant, mixed, and lymphocyte-dominant. Immune-related transcript profiles from lymphocyte-dominant MoM- and MoP-associated ALTR patients with perivascular lymphocytic aggregates were similar. Cell signatures indicated predominantly macrophage, Th1 and Th2 lymphocytic infiltrate, with strong exhausted CD8+ signature, and low Th17 and B cell, relative to healthy lymph nodes. Lymphocyte-dominant ALTR-associated synovial fluid contained higher levels of induced protein 10 (IP-10), interleukin-1 receptor antagonist (IL-1RN), IL-8, IL-6, IL-16, macrophage inflammatory protein 1 (MIP-1α), IL-18, MCP-2, and lower cell-attracting chemokine levels, when compared with prosthetic revisions lacking ALTRs. In addition, the higher levels of IP-10, IL-8, IL-6, MIP-1α, and MCP-2 were observed within the synovial fluid of the lymphocyte-dominant ALTRs relative to the macrophage-dominant ALTRs. Not all cytokines/chemokines were detected in the perivascular aggregate transcripts, suggesting the existence of other sources in the affected synovia. Our results support the hypothesis of common hypersensitivity pathogenesis in lymphocyte-dominant MoM and MoP ALTRs. The exhausted lymphocyte signature indicates chronic processes and an impaired immune response, although the cause of the persistent T-cell activation remains unclear. The cytokine/chemokine signature of lymphocyte-dominant-associated ATLRs may be of utility for diagnosing this more aggressive pathogenesis.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,Vancouver Prostate Centre, Vancouver, British Columbia, Canada
| | - Nissreen Mohammad
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | | | - Anne Haegert
- Vancouver Prostate Centre, Vancouver, British Columbia, Canada
| | - Clive P Duncan
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada.,Centre for Hip Health and Mobility, Vancouver, British Columbia, Canada
| | - Nelson V Greidanus
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Bassam A Masri
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada.,Centre for Hip Health and Mobility, Vancouver, British Columbia, Canada
| | - Tony L Ng
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,Centre for Hip Health and Mobility, Vancouver, British Columbia, Canada
| | - Michael E Cox
- Vancouver Prostate Centre, Vancouver, British Columbia, Canada.,Department of Urologic Sciences, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
5
|
Eltit F, Noble J, Sharma M, Benam N, Haegert A, Bell RH, Simon F, Duncan CP, Garbuz DS, Greidanus NV, Masri BA, Ng TL, Wang R, Cox ME. Cobalt ions induce metabolic stress in synovial fibroblasts and secretion of cytokines/chemokines that may be diagnostic markers for adverse local tissue reactions to hip implants. Acta Biomater 2021; 131:581-594. [PMID: 34192572 DOI: 10.1016/j.actbio.2021.06.039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/17/2021] [Accepted: 06/22/2021] [Indexed: 12/18/2022]
Abstract
Adverse local tissue reactions (ALTRs) are a prominent cause of hip implant failure. ALTRs are characterized by aseptic necrosis and leukocyte infiltration of synovial tissue. The prevalence of ALTRs in hips with failing metal implants, with highest rates occurring in patients with metal-on-metal articulations, suggests a role for CoCrMo corrosion in ALTR formation. Although hypersensitivity reactions are the most accepted etiology, the precise cellular mechanism driving ALTR pathogenesis remains enigmatic. Here we show that cobalt ions released by failing hip implants induce mitochondrial stress and cytokine secretion by synovial fibroblasts: the presumptive initiators of ALTR pathogenesis. We found that in-vitro treatment of synovial fibroblasts with cobalt, but not chromium, generated gene expression changes indicative of hypoxia and mitophagy responses also observed in ALTRs biopsies. Inflammatory factors secreted by cobalt-exposed synovial fibroblasts were among those most concentrated in ALTR synovial fluid. Furthermore, both conditioned media from cobalt-exposed synovial fibroblasts, and synovial fluid from ALTRs patients, elicit endothelial activation and monocyte migration. Finally, we identify the IL16/CTACK ratio in synovial fluid as a possible diagnostic marker of ALTRs. Our results provide evidence suggesting that metal ions induce cell stress in synovial fibroblasts that promote an inflammatory response consistent with initiating ALTR formation. STATEMENT OF SIGNIFICANCE: We demonstrate that the cytotoxic effects of cobalt ions on the synovial cells (fibroblast) is sufficient to trigger inflammation on hip joints with metal implants. Cobalt ions affect mitochondrial function, leading to the auto phagocytosis of mitochondria and trigger a hypoxic response. The cell's hypoxic response includes secretion of cytokines that are capable of trigger inflammation by activating blood vessels and enhancing leukocyte migration. Among the secreted cytokines is IL-16, which is highly concentrated in the synovial fluid of the patients with adverse local tissue reactions and could be use as diagnostic marker. In conclusion we define the cells of the hip joint as key players in triggering the adverse reactions to hip implants and providing biomarkers for early diagnosis of adverse reactions to hip implants.
Collapse
|
6
|
McCarthy SM, Hall DJ, Mathew MT, Jacobs JJ, Lundberg HJ, Pourzal R. Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res 2021; 479:2083-2096. [PMID: 34019490 PMCID: PMC8373544 DOI: 10.1097/corr.0000000000001819] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 04/19/2021] [Indexed: 01/31/2023]
Abstract
BACKGROUND Fretting and corrosion in metal-on-polyethylene total hip arthoplasty (THA) modular junctions can cause adverse tissue reactions that are responsible for 2% to 5% of revision surgeries. Damage within cobalt-chromium-molybdenum (CoCrMo) alloy femoral heads can progress chemically and mechanically, leading to damage modes such as column damage, imprinting, and uniform fretting damage. At present, it is unclear which of these damage modes are most detrimental and how they may be linked to implant alloy metallurgy. The alloy microstructure exhibits microstructural features such as grain boundaries, hard phases, and segregation bands, which may enable different damage modes, higher material loss, and the potential risk of adverse local tissue reactions. QUESTIONS/PURPOSES In this study, we asked: (1) How prevalent is chemically dominated column damage compared with mechanically dominated damage modes in severely damaged metal-on-polyethylene THA femoral heads made from wrought CoCrMo alloy? (2) Is material loss greater in femoral heads that underwent column damage? (3) Do material loss and the presence of column damage depend on alloy microstructure as characterized by grain size, hard phase content, and/or banding? METHODS Surgically retrieved wrought CoCrMo modular femoral heads removed between June 2004 and June 2019 were scored using a modified version of the Goldberg visually based scoring system. Of the total 1002 heads retrieved over this period, 19% (190 of 1002) were identified as severely damaged, exhibiting large areas of fretting scars, black debris, pits, and/or etch marks. Of these, 43% (81 of 190) were excluded for metal-on-metal articulations, alternate designs (such as bipolar, dual-mobility, hemiarthroplasty, metal adaptor sleeves), or previous sectioning of the implant for past studies. One sample was excluded retroactively as metallurgical analysis revealed that it was made of cast alloy, yielding a total of 108 for further analysis. Information on patient age (57 ± 11 years) and sex (56% [61 of 108] were males), reason for removal, implant time in situ (99 ± 78 months), implant manufacturer, head size, and the CoCrMo or titanium-based stem alloy pairing were collected. Damage modes and volumetric material loss within the head tapers were identified using an optical coordinate measuring machine. Samples were categorized by damage mode groups by column damage, imprinting, a combination of column damage and imprinting, or uniform fretting. Metallurgical samples were processed to identify microstructural characteristics of grain size, hard phase content, and banding. Nonparametric Mann-Whitney U and Kruskal-Wallis statistical tests were used to examine volumetric material loss compared with damage mode and microstructural features, and linear regression was performed to correlate patient- and manufacturer-specific factors with volumetric material loss. RESULTS Chemically driven column damage was seen in 48% (52 of 108) of femoral heads, with 34% (37 of 108) exhibiting a combination of column damage and imprinting, 12% (13 of 108) of heads displaying column damage and uniform fretting, and 2% (2 of 108) exhibiting such widespread column damage that potentially underlying mechanical damage modes could not be verified. Implants with column damage showed greater material loss than those with mechanically driven damage alone, with median (range) values of 1.2 mm3 (0.2 to 11.7) versus 0.6 mm3 (0 to 20.7; p = 0.03). Median (range) volume loss across all femoral heads was 0.9 mm3 (0 to 20.7). Time in situ, contact area, patient age, sex, head size, manufacturer, and stem alloy type were not associated with volumetric material loss. Banding of the alloy microstructure, with a median (range) material loss of 1.1 mm3 (0 to 20.7), was associated with five times higher material loss compared with those with a homogeneous microstructure, which had a volume loss of 0.2 mm3 (0 to 4.1; p = 0.02). Hard phase content and grain size showed no correlation with material loss. CONCLUSION Chemically dominated column damage was a clear indicator of greater volume loss in this study sample of 108 severely damaged heads. Volumetric material loss strongly depended on banding (microstructural segregations) within the alloy. Banding of the wrought CoCrMo microstructure should be avoided during the manufacturing process to reduce volumetric material loss and the release of corrosion products to the periprosthetic tissue. CLINICAL RELEVANCE Approximately 30% of THAs rely on wrought CoCrMo femoral heads. Most femoral heads in this study exhibited a banded microstructure that was associated with larger material loss and the occurrence of chemically dominated column damage. This study suggests that elimination of banding from the alloy could substantially reduce the release of implant debris in vivo, which could potentially also reduce the risk of adverse local tissue reactions to implant debris.
Collapse
Affiliation(s)
| | - Deborah J. Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | | | - Joshua J. Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
7
|
Perino G, De Martino I, Zhang L, Xia Z, Gallo J, Natu S, Langton D, Huber M, Rakow A, Schoon J, Gomez-Barrena E, Krenn V. The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty. EFORT Open Rev 2021; 6:399-419. [PMID: 34267931 PMCID: PMC8246109 DOI: 10.1302/2058-5241.6.210013] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The histopathological examination of the periprosthetic soft tissue and bone has contributed to the identification and description of the morphological features of adverse local tissue reactions (ALTR)/adverse reactions to metallic debris (ARMD). The need of a uniform vocabulary for all disciplines involved in the diagnosis and management of ALTR/ARMD and of clarification of the parameters used in the semi-quantitative scoring systems for their classification has been considered a pre-requisite for a meaningful interdisciplinary evaluation. This review of key terms used for ALTR/ARMD has resulted in the following outcomes: (a) pseudotumor is a descriptive term for ALTR/ARMD, classifiable in two main types according to its cellular composition defining its clinical course; (b) the substitution of the term metallosis with presence of metallic wear debris, since it cannot be used as a category of implant failure or histological diagnosis; (c) the term aseptic lymphocytic-dominated vasculitis- associated lesion (ALVAL) should be replaced due to the absence of a vasculitis with ALLTR/ALRMD for lymphocytic-predominant and AMLTR/AMRMD for macrophage-predominant reaction. This review of the histopathological classifications of ALTR/ARMD has resulted in the following outcomes: (a) distinction between cell death and tissue necrosis; (b) the association of corrosion metallic debris with adverse local lymphocytic reaction and tissue necrosis; (c) the importance of cell and particle debris for the viscosity and density of the lubricating synovial fluid; (d) a consensus classification of lymphocytic infiltrate in soft tissue and bone marrow; (e) evaluation of the macrophage infiltrate in soft tissues and bone marrow; (f) classification of macrophage induced osteolysis/aseptic loosening as a delayed type of ALTR/ARMD; (g) macrophage motility and migration as possible driving factor for osteolysis; (h) usefulness of the histopathological examination for the natural history of the adverse reactions, radiological correlation, post-marketing surveillance, and implant registries. The review of key terms used for the description and histopathological classification of ALTR/ARMD has resulted in a comprehensive, new standard for all disciplines involved in their diagnosis, clinical management, and long-term clinical follow-up.
Cite this article: EFORT Open Rev 2021;6:399-419. DOI: 10.1302/2058-5241.6.210013
Collapse
Affiliation(s)
- Giorgio Perino
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Lingxin Zhang
- Department of Pathology and Laboratory Medicine, Sinai Health System, Toronto, Canada
| | - Zhidao Xia
- Centre for Nanohealth, Swansea University Medical School, Singleton Park, Swansea, UK
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, University Hospital, Palacky University Olomouc, Czech Republic
| | - Shonali Natu
- Department of Pathology, University Hospital of North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| | - David Langton
- Orthopaedic Department, Freeman Hospital, Newcastle upon Tyne, UK
| | - Monika Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Austria
| | - Anastasia Rakow
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Janosch Schoon
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Enrique Gomez-Barrena
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario La Paz-IdiPAZ, Universidad Autónoma de Madrid, Madrid, Spain
| | - Veit Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik-GmbH, Trier, Germany
| |
Collapse
|
8
|
Zajc J, Moličnik A, Fokter SK. Dual Modular Titanium Alloy Femoral Stem Failure Mechanisms and Suggested Clinical Approaches. Materials (Basel) 2021; 14:3078. [PMID: 34199983 DOI: 10.3390/ma14113078] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/27/2021] [Accepted: 06/02/2021] [Indexed: 12/13/2022]
Abstract
Titanium (Ti) alloys have been proven to be one of the most suitable materials for orthopaedic implants. Dual modular stems have been introduced to primary total hip arthroplasty (THA) to enable better control of the femoral offset, leg length, and hip stability. This systematic review highlights information acquired for dual modular Ti stem complications published in the last 12 years and offers a conclusive discussion of the gathered knowledge. Articles referring to dual modular stem usage, survivorship, and complications in English were searched from 2009 to the present day. A qualitative synthesis of literature was carried out, excluding articles referring solely to other types of junctions or problems with cobalt-chromium alloys in detail. In total, 515 records were identified through database searching and 78 journal articles or conference proceedings were found. The reasons for a modular neck fracture of a Ti alloy are multifactorial. Even though dual modular stems have not shown any clinical benefits for patients and have been associated with worse results regarding durability than monolithic stems, some designs are still marketed worldwide. Orthopaedic surgeons should use Ti6Al4V dual modular stem designs for primary THA in special cases only.
Collapse
|
9
|
Salloum Z, Lehoux EA, Harper ME, Catelas I. Effects of cobalt and chromium ions on glycolytic flux and the stabilization of hypoxia-inducible factor-1α in macrophages in vitro. J Orthop Res 2021; 39:112-120. [PMID: 32462687 DOI: 10.1002/jor.24758] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 05/15/2020] [Accepted: 05/25/2020] [Indexed: 02/04/2023]
Abstract
Implant wear and corrosion have been associated with adverse tissue reactions that can lead to implant failure. Wear and corrosion products are therefore of great clinical concern. For example, Co2+ and Cr3+ originating from CoCrMo-based implants have been shown to induce a proinflammatory response in macrophages in vitro. Previous studies have also shown that the polarization of macrophages by some proinflammatory stimuli is associated with a hypoxia-inducible factor-1α (HIF-1α)-dependent metabolic shift from oxidative phosphorylation (OXPHOS) towards glycolysis. However, the potential of Co2+ and Cr3+ to induce this metabolic shift, which plays a determining role in the proinflammatory response of macrophages, remains largely unexplored. We recently demonstrated that Co2+ , but not Cr3+ , increased oxidative stress and decreased OXPHOS in RAW 264.7 murine macrophages. In the present study, we analyzed the effects of Co2+ and Cr3+ on glycolytic flux and HIF-1α stabilization in the same experimental model. Cells were exposed to 6 to 24 ppm Co2+ or 50 to 250 ppm Cr3+ . Glycolytic flux was determined by analyzing extracellular flux and lactate production, while HIF-1α stabilization was analyzed by immunoblotting. Results showed that Co2+ , and to a lesser extent Cr3+ , increased glycolytic flux; however, only Co2+ acted through HIF-1α stabilization. Overall, these results, together with our previous results showing that Co2+ increases oxidative stress and decreases OXPHOS, suggest that Co2+ (but not Cr3+ ) can induce a HIF-1α-dependent metabolic shift from OXPHOS towards glycolysis in macrophages. This metabolic shift may play an early and pivotal role in the inflammatory response induced by Co2+ in the periprosthetic environment.
Collapse
Affiliation(s)
- Zeina Salloum
- Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Eric A Lehoux
- Department of Mechanical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario, Canada
| | - Mary-Ellen Harper
- Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.,Ottawa Institute of Systems Biology, University of Ottawa, Ottawa, Ontario, Canada
| | - Isabelle Catelas
- Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.,Department of Mechanical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario, Canada.,Department of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
10
|
Abstract
Adverse local tissue reactions (ALTRs) were first associated with patients with failed metal-on-metal surface replacements and total hip arthroplasty (THA). However, an increasing number of cases of ALTR in metal-on-polyethylene (MOP) THA patients is being reported. Clinically, ALTR appears as benign, aseptic masses or bursae in the periprosthetic tissues. Histopathologically, ALTRs are distinguished by an intense lymphocyte infiltrate, destruction of the synovial surfaces, widespread necrosis, and fibrin exudate. Tribocorrosion of modular junctions appears to be the cause of ALTR in MOP patients. The various tribocorrosion damage modes occurring at modular junctions produce metal ions and a diversity of particulates in relation to size, chemical composition, and structure. The mechanisms by which these various products of tribocorrosion lead to ALTR are still a matter of considerable research. This review clarifies what constitutes ALTR, its relationship to implant factors, and highlights current methods for diagnosis and management of patients with ALTR in the setting of MOP THA.
Collapse
Affiliation(s)
- Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
11
|
Hobza M, Milde D, Slobodova Z, Gallo J. The number of lymphocytes increases in the periprosthetic tissues with increasing time of implant service in non-metal-on-metal total joint arthroplasties: A role of metallic byproducts? Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2020; 165:416-427. [PMID: 32435063 DOI: 10.5507/bp.2020.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Accepted: 04/27/2020] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND The objective of the study was to determine the association between periprosthetic concentrations of selected metals and changes induced in periprosthetic tissues (PT). METHODS PT from 24 patients with metal-on-polyethylene or ceramic-on-polyethylene total joint replacements (TJRs) were examined. Samples underwent histological examination including quantification of cellular populations. Determination of metals was performed according to the published methodology. Results were processed using correlation analysis and Principal Component Analysis (PCA), respectively. RESULTS Growing concentration of metals in the PT was found as a function of length of exposure (LoE). Differences in Ti, Co, Cr and V concentrations (per α = 0.05) depended on the type of alloy the implants were made from. On the contrary, the implant composition did not reflect in the different numbers of immune cells per 1 high power field, not even in distribution of the membrane type according to the Krenn classification. PCA revealed several clusters in dependence on the LoE, type of the membrane and presence of immune cells. High representation of lymphocytes in the PT was typical for clusters with the longest LoE while a higher representation of neutrophils was typical for a shorter time to reoperation. CONCLUSIONS Correlation between the LoE and concentrations of metals in its surroundings was demonstrated. However, the tissue image analysis cannot differentiate finer, potentially metal-induced tissue changes. Importantly, the tissues become more similar with an increasing LoE. We draw a conclusion about predominantly non-specific stimulation of the PT jointly by metal and polyethylene particles in non-metal-on-metal TJRs.
Collapse
Affiliation(s)
- Martin Hobza
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00, Olomouc, Czech Republic
| | - David Milde
- Department of Analytical Chemistry, Faculty of Science, Palacky University Olomouc, 17. listopadu 12, 771 46 Olomouc, Czech Republic
| | - Zuzana Slobodova
- Department of Clinical and Molecular Pathology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc, Czech Republic
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00, Olomouc, Czech Republic
| |
Collapse
|
12
|
Wang Q, Eltit F, Garbuz D, Duncan C, Masri B, Greidanus N, Wang R. CoCrMo metal release in metal‐on‐highly crosslinked polyethylene hip implants. J Biomed Mater Res B Appl Biomater 2020; 108:1213-1228. [DOI: 10.1002/jbm.b.34470] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/18/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023]
Affiliation(s)
- Qiong Wang
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| | - Felipe Eltit
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| | - Donald Garbuz
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Clive Duncan
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Bassam Masri
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Nelson Greidanus
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Rizhi Wang
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| |
Collapse
|
13
|
Grupp TM, Baxmann M, Jansson V, Windhagen H, Heller KD, Morlock MM, Knaebel HP. How to proceed with asymptomatic modular dual taper hip stems in the case of acetabular revision. Materials (Basel) 2020; 13:ma13051098. [PMID: 32121627 PMCID: PMC7084958 DOI: 10.3390/ma13051098] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 02/13/2020] [Accepted: 02/18/2020] [Indexed: 12/15/2022]
Abstract
How to proceed with a clinically asymptomatic modular Metha® Ti alloy stem with dual taper CoCr neck adapter in case of acetabular revision? To systematically answer this question the status of research and appropriate diagnostic methods in context to clinically symptomatic and asymptomatic dual taper stem-neck couplings has been evaluated based on a systematic literature review. A retrieval analysis of thirteen Metha® modular dual taper CoCr/Ti alloy hip stems has been performed and a rational decision making model as basis for a clinical recommendation was developed. From our observations we propose that in cases of acetabular revision, that for patients with a serum cobalt level of > 4 µg/L and a Co/Cr ratio > 3.6, the revision of the modular dual taper stem may be considered. Prior to acetabular revision surgery a systematic diagnostic evaluation should be executed, using specific tests such as serum metal (Co, Cr) ion analysis, plain antero-posterior and lateral radiographs and cross-sectional imaging modalities (Metal Artefact Reduction Sequence Magnetic Resonance Imaging). For an asymptomatic Metha® dual taper Ti alloy/CoCr stem-neck coupling at the stage of acetabular revision careful clinical decision making according to the proposed model should be followed and overreliance on any single examination should be avoided, considering the complete individual differential diagnosis and patient situation.
Collapse
Affiliation(s)
- Thomas M. Grupp
- Aesculap AG Research & Development, 78532 Tuttlingen, Germany;
- Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern Ludwig Maximilians University Munich, 81377 Munich, Germany;
- Correspondence: ; Tel.: +49-7461-95-2667; Fax: +49-7461-95-382667
| | - Marc Baxmann
- Aesculap AG Research & Development, 78532 Tuttlingen, Germany;
| | - Volkmar Jansson
- Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern Ludwig Maximilians University Munich, 81377 Munich, Germany;
| | - Henning Windhagen
- Department of Orthopaedic Surgery, Hannover Medical School, 30625 Hannover, Germany;
| | - Karl-Dieter Heller
- Department of Orthopaedic Surgery, Herzogin-Elisabeth-Hospital, 38124 Braunschweig, Germany;
| | - Michael M. Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany;
| | | |
Collapse
|
14
|
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
15
|
Salloum Z, Lehoux EA, Harper ME, Catelas I. Effects of cobalt and chromium ions on oxidative stress and energy metabolism in macrophages in vitro. J Orthop Res 2018; 36:3178-3187. [PMID: 30144138 DOI: 10.1002/jor.24130] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Accepted: 07/21/2018] [Indexed: 02/04/2023]
Abstract
Cobalt and chromium ions released from cobalt-chromium-molybdenum (CoCrMo)-based implants are a potential health concern, especially since both ions have been shown to induce oxidative stress in macrophages, the predominant immune cells in periprosthetic tissues. Ions of other transition metals (Cd, Ni) have been reported to inhibit the activity of mitochondrial enzymes in the electron transport chain. However, the effects of Co and Cr ions on the energy metabolism of macrophages remain largely unknown. The objective of the present study was to analyze the effects of Co2+ and Cr3+ on oxidative stress and energy metabolism in macrophages in vitro. RAW 264.7 murine macrophages were exposed to 6-18 ppm Co2+ or 50-150 ppm Cr3+ . Results showed a significant increase in two markers of oxidative stress, reactive oxygen species level and protein carbonyl content, with increasing concentrations of Co2+ , but not with Cr3+ . In addition, oxygen consumption rates (OCR; measured using an extracellular flux analyzer) showed significant decreases in both mitochondrial respiration and non-mitochondrial oxygen consumption with increasing concentrations of Co2+ , but not with Cr3+ . OCR results further showed that Co2+ , but not Cr3+ , induced mitochondrial dysfunction, including a decrease in oxidative phosphorylation capacity. Overall, this study suggests that mitochondrial dysfunction may contribute to Co2+ -induced oxidative stress in macrophages, and thereby to the inflammatory response observed in periprosthetic tissues. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3178-3187, 2018.
Collapse
Affiliation(s)
- Zeina Salloum
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| | - Eric A Lehoux
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Mary-Ellen Harper
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| | - Isabelle Catelas
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5.,Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5.,Department of Surgery, University of Ottawa, The Ottawa Hospital-General Campus, 501 Smyth Road, Ottawa, Ontario, Canada, K1H 8L6
| |
Collapse
|
16
|
Perino G, Sunitsch S, Huber M, Ramirez D, Gallo J, Vaculova J, Natu S, Kretzer JP, Müller S, Thomas P, Thomsen M, Krukemeyer MG, Resch H, Hügle T, Waldstein W, Böettner F, Gehrke T, Sesselmann S, Rüther W, Xia Z, Purdue E, Krenn V. Diagnostic guidelines for the histological particle algorithm in the periprosthetic neo-synovial tissue. BMC Clin Pathol 2018; 18:7. [PMID: 30158837 PMCID: PMC6109269 DOI: 10.1186/s12907-018-0074-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 08/16/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND The identification of implant wear particles and non-implant related particles and the characterization of the inflammatory responses in the periprosthetic neo-synovial membrane, bone, and the synovial-like interface membrane (SLIM) play an important role for the evaluation of clinical outcome, correlation with radiological and implant retrieval studies, and understanding of the biological pathways contributing to implant failures in joint arthroplasty. The purpose of this study is to present a comprehensive histological particle algorithm (HPA) as a practical guide to particle identification at routine light microscopy examination. METHODS The cases used for particle analysis were selected retrospectively from the archives of two institutions and were representative of the implant wear and non-implant related particle spectrum. All particle categories were described according to their size, shape, colour and properties observed at light microscopy, under polarized light, and after histochemical stains when necessary. A unified range of particle size, defined as a measure of length only, is proposed for the wear particles with five classes for polyethylene (PE) particles and four classes for conventional and corrosion metallic particles and ceramic particles. RESULTS All implant wear and non-implant related particles were described and illustrated in detail by category. A particle scoring system for the periprosthetic tissue/SLIM is proposed as follows: 1) Wear particle identification at light microscopy with a two-step analysis at low (× 25, × 40, and × 100) and high magnification (× 200 and × 400); 2) Identification of the predominant wear particle type with size determination; 3) The presence of non-implant related endogenous and/or foreign particles. A guide for a comprehensive pathology report is also provided with sections for macroscopic and microscopic description, and diagnosis. CONCLUSIONS The HPA should be considered a standard for the histological analysis of periprosthetic neo-synovial membrane, bone, and SLIM. It provides a basic, standardized tool for the identification of implant wear and non-implant related particles at routine light microscopy examination and aims at reducing intra-observer and inter-observer variability to provide a common platform for multicentric implant retrieval/radiological/histological studies and valuable data for the risk assessment of implant performance for regional and national implant registries and government agencies.
Collapse
Affiliation(s)
- G. Perino
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 E 70th Street, New York, NY 10023 USA
| | - S. Sunitsch
- Medizinische Universität Graz, Institut für Pathologie, Graz, Austria
| | - M. Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Austria
| | - D. Ramirez
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 E 70th Street, New York, NY 10023 USA
| | - J. Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, University Hospital, Palacky University Olomouc, Olomouc, Czech Republic
| | - J. Vaculova
- Department of Pathology, Fakultni Nemocnice Ostrava, Ostrava, Czech Republic
| | - S. Natu
- Department of Pathology, University hospital of North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| | - J. P. Kretzer
- Labor für Biomechanik und Implantat-Forschung, Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Heidelberg, Heidelberg, Germany
| | - S. Müller
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Trier, Germany
| | - P. Thomas
- LMU Klinik, Klinik und Poliklinik für Dermatologie und Allergologie, Munich, Germany
| | - M. Thomsen
- Baden-Baden Klinik, Baden-Baden, Germany
| | | | - H. Resch
- Universitätsklinik für Unfallchirurgie und Sporttraumatologie, Salzburg, Austria
| | - T. Hügle
- Hôpital Orthopédique, Lausanne, Switzerland
| | - W. Waldstein
- Medizinische Universität Wien, AKH-Wien, Universitätsklinik für Orthopädie, Wien, Austria
| | - F. Böettner
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY USA
| | - T. Gehrke
- Helios Endo-Klinik, Hamburg, Germany
| | - S. Sesselmann
- Orthopädische Universitätsklinik Erlangen, Erlangen, Germany
| | - W. Rüther
- Klinik und Poliklinik für Orthopädie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Z. Xia
- Centre for Nanohealth, Swansea University Medical School, Singleton Park, Swansea, UK
| | - E. Purdue
- Hospital for Special Surgery, Research Institute, New York, NY USA
| | - V. Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Trier, Germany
| |
Collapse
|
17
|
Catelas I, Lehoux EA, Ning Z, Figeys D, Baskey SJ, Beaulé PE. Differential proteomic analysis of synovial fluid from hip arthroplasty patients with a pseudotumor vs. Periprosthetic osteolysis . J Orthop Res 2018; 36:1849-1859. [PMID: 29352728 DOI: 10.1002/jor.23858] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 01/08/2018] [Indexed: 02/04/2023]
Abstract
Adverse tissue reactions to metal implants, including pseudotumors, can compromise implant functionality and survivorship. The identification of specific proteins in the synovial fluid (SF) of hip arthroplasty patients with a pseudotumor may lead to a better understanding of the underlying pathomechanisms. The objective of the present study was to compare the protein content of SF from patients with a short-term metal-on-metal hip implant associated with a pseudotumor and patients with a long-term metal-on-polyethylene hip implant associated with periprosthetic osteolysis. Discovery proteomics was used to identify differentially abundant proteins in albumin-depleted SF. In toto, 452 distinct proteins (present in at least half of the patients in one or both groups) were identified. Thirty of these 452 proteins were differentially abundant between the two groups, including two potential biomarkers: 6-phosphogluconate dehydrogenase (which plays a major protective role against oxidative stress) for the pseudotumor group, and scavenger receptor cysteine-rich type 1 protein M130 (which is involved in low-grade inflammation) for the periprosthetic osteolysis group. Other differentially abundant proteins identified suggest the presence of an adaptive immune response (particularly a type-IV hypersensitivity reaction), necrosis, and greater oxidative stress in patients with a pseudotumor. They also suggest the presence of an innate immune response, oxidative stress, tissue remodeling, and apoptosis in both patient groups, although differences in the specific proteins identified in each group point to differences in the pathomechanisms. Overall, results provide insights into the molecular mechanisms underlying metal-related pseudotumors and periprosthetic osteolysis, and may ultimately help elucidate pseudotumor etiology and assess the risk that asymptomatic pseudotumors will develop into an aggressive lesion. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1849-1859, 2018.
Collapse
Affiliation(s)
- Isabelle Catelas
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5.,Department of Surgery, Division of Orthopaedic Surgery, University of Ottawa, The Ottawa Hospital-General Campus, 501 Smyth Road, Ottawa, Ontario, Canada, K1H 8L6.,Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| | - Eric A Lehoux
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Zhibin Ning
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5.,Ottawa Institute of Systems Biology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| | - Daniel Figeys
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5.,Ottawa Institute of Systems Biology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| | - Stephen J Baskey
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Paul E Beaulé
- Department of Surgery, Division of Orthopaedic Surgery, University of Ottawa, The Ottawa Hospital-General Campus, 501 Smyth Road, Ottawa, Ontario, Canada, K1H 8L6
| |
Collapse
|
18
|
Kleeman LT, Bala A, Penrose CT, Seyler TM, Wellman SS, Bolognesi MP. Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population. J Arthroplasty 2018; 33:1826-32. [PMID: 29510952 DOI: 10.1016/j.arth.2018.01.066] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/18/2018] [Accepted: 01/25/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The use of metal-on-metal (MoM) hip bearings has declined in the recent years due to strong evidence of their high complication rates and early failure. Hip implants with highly cross-linked polyethylene liners and ceramic bearings have become the modern implants of choice. We sought to determine if MoM implants are associated with higher complication and revision rates when compared to other hip bearings in the Medicare population. METHODS We retrospectively reviewed a Medicare database (2005-2011) for patients who underwent a primary total hip arthroplasty with a MoM, metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), or ceramic-on-ceramic (CoC) implant (minimum 2 years of follow-up). Patient comorbidities and medical/surgical complication rates were analyzed at various time points postoperatively. RESULTS We identified 288,118 patients, including 81,520 patients with a MoM implant, 162,881 with MoP, 33,819 with CoP, and 9898 with CoC implant. Surgical complication rates were higher for MoM implants including infection, osteolysis/polywear, mechanical complications, and need for hip irrigation and debridement. Overall revision rates were significantly higher for MoM implants (5.28%) compared to MoP (4.28%, odds ratio [OR] 1.26, P < .001) and CoP (3.52%, OR 1.55, P < .001) but only by one to two percent. MoM revision rates were similar to CoC implants (4.94%, OR 1.00, P = .096). CONCLUSIONS MoM implants were associated with higher revision rates (5.28%) compared to MoP (4.28%) and CoP (3.52%) implants in the Medicare population. Both complication and revision rates were comparable to CoC implants.
Collapse
|
19
|
Xu J, Yang J, Nyga A, Ehteramyan M, Moraga A, Wu Y, Zeng L, Knight MM, Shelton JC. Cobalt (II) ions and nanoparticles induce macrophage retention by ROS-mediated down-regulation of RhoA expression. Acta Biomater 2018; 72:434-446. [PMID: 29649639 PMCID: PMC5953279 DOI: 10.1016/j.actbio.2018.03.054] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2017] [Revised: 03/15/2018] [Accepted: 03/30/2018] [Indexed: 02/06/2023]
Abstract
Histological assessments of synovial tissues from patients with failed CoCr alloy hip prostheses demonstrate extensive infiltration and accumulation of macrophages, often loaded with large quantities of particulate debris. The resulting adverse reaction to metal debris (ARMD) frequently leads to early joint revision. Inflammatory response starts with the recruitment of immune cells and requires the egress of macrophages from the inflamed site for resolution of the reaction. Metal ions (Co2+ and Cr3+) have been shown to stimulate the migration of T lymphocytes but their effects on macrophages motility are still poorly understood. To elucidate this, we studied in vitro and in vivo macrophage migration during exposure to cobalt and chromium ions and nanoparticles. We found that cobalt but not chromium significantly reduces macrophage motility. This involves increase in cell spreading, formation of intracellular podosome-type adhesion structures and enhanced cell adhesion to the extracellular matrix (ECM). The formation of podosomes was also associated with the production and activation of matrix metalloproteinase-9 (MMP9) and enhanced ECM degradation. We showed that these were driven by the down-regulation of RhoA signalling through the generation of reactive oxygen species (ROS). These novel findings reveal the key mechanisms driving the wear/corrosion metallic byproducts-induced inflammatory response at non-toxic concentrations. Statement of significance Adverse tissue responses to metal wear and corrosion products from CoCr alloy implants remain a great challenge to surgeons and patients. Macrophages are the key regulators of these adverse responses to the ions and debris generated. We demonstrated that cobalt, rather than chromium, causes macrophage retention by restructuring the cytoskeleton and inhibiting cell migration via ROS production that affects Rho Family GTPase. This distinctive effect of cobalt on macrophage behaviour can help us understand the pathogenesis of ARMD and the cellular response to cobalt based alloys, which provide useful information for future implant design and biocompatibility testing.
Collapse
Affiliation(s)
- Jing Xu
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | - Junyao Yang
- Department of Laboratory Medicine, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200092, China
| | - Agata Nyga
- Division of Surgery and Interventional Sciences, University College London, London NW3 2QG, United Kingdom; Institute for Bioengineering of Catalonia, 08028 Barcelona, Spain
| | - Mazdak Ehteramyan
- Cardiovascular Division, Faculty of Life Science and Medicine, King's College London, London SE5 9NU, United Kingdom
| | - Ana Moraga
- Cardiovascular Division, Faculty of Life Science and Medicine, King's College London, London SE5 9NU, United Kingdom
| | - Yuanhao Wu
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | - Lingfang Zeng
- Cardiovascular Division, Faculty of Life Science and Medicine, King's College London, London SE5 9NU, United Kingdom.
| | - Martin M Knight
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK.
| | - Julia C Shelton
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK.
| |
Collapse
|
20
|
Lehtovirta L, Reito A, Parkkinen J, Hothi H, Henckel J, Hart A, Eskelinen A. Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings. BMC Musculoskelet Disord 2017; 18:523. [PMID: 29228956 PMCID: PMC5725985 DOI: 10.1186/s12891-017-1894-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 12/04/2017] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Adverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations. METHODS Seventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components. RESULTS Volumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis. CONCLUSIONS Bearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response.
Collapse
Affiliation(s)
- Lari Lehtovirta
- Faculty of Medicine, University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | | | |
Collapse
|
21
|
Bauer TW. CORR Insights ®: Current Pathologic Scoring Systems for Metal-on-metal THA Revisions are not Reproducible. Clin Orthop Relat Res 2017; 475:3012-3014. [PMID: 28956270 PMCID: PMC5670081 DOI: 10.1007/s11999-017-5512-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 09/22/2017] [Indexed: 01/31/2023]
Affiliation(s)
- Thomas W. Bauer
- 0000 0001 2285 8823grid.239915.5Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 East 70th St., New York, NY 10021 USA
| |
Collapse
|
22
|
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
23
|
Abstract
INTRODUCTION Endoprostheses of the ankle joint show higher revision rates of 3.29 revisions per 100 component years. The aims of this study were the application and modification of the consensus classification of the synovia-like interface membrane (SLIM) for periprosthetic failure of the ankle joint, the etiological clarification of periprosthetic pseudocysts and a detailed measurement of proliferative activity (Ki67) in the region of osteolysis. MATERIAL AND METHOD Tissue samples from 159 patients were examined according to the criteria of the standardized consensus classification. Of these, 117 cases were derived from periprosthetic membranes of the ankle. The control group included 42 tissue specimens from the hip and knee joints. Particle identification and characterization were carried out using the particle algorithm. An immunohistochemical examination with Ki67 proliferation was performed in all cases of ankle pseudocysts and 19 control cases. RESULTS The consensus classification of SLIM is transferrable to endoprosthetic failure of the ankle joint. Periprosthetic pseudocysts with the histopathological characteristics of the appropriate SLIM subtype were detectable in 39 cases of ankle joint endoprostheses (33.3%). The mean value of the Ki67 index was 14% and showed an increased proliferation rate in periprosthetic pseudocysts of the ankle (p-value 0.02037). CONCLUSION In periprosthetic pseudocysts an above average higher detection rate of type 1 SLIM induced by abrasion (51.3%) with an increased Ki67 proliferation fraction (p-value 0.02037) was found, which can be interpreted as local destructive intraosseus synovialitis. This can be the reason for formation of pseudocystic osteolysis caused by high mechanical stress in ankle endoprostheses. A simplified diagnostic classification scoring system of dysfunctional endoprostheses of the ankle is proposed for collation of periprosthetic pseudocysts, ossifications and the Ki67 proliferation fraction.
Collapse
Affiliation(s)
- S Müller
- Zentrum für Histologie, Zytologie und molekulare Diagnostik, Max-Planck-Straße 5, 54296, Trier, Deutschland.
| | - M Walther
- Schön-Klinik München-Harlaching, München, Deutschland
| | - A Röser
- Schön-Klinik München-Harlaching, München, Deutschland
| | - V Krenn
- Zentrum für Histologie, Zytologie und molekulare Diagnostik, Max-Planck-Straße 5, 54296, Trier, Deutschland
| |
Collapse
|
24
|
Hopf F, Thomas P, Sesselmann S, Thomsen MN, Hopf M, Hopf J, Krukemeyer MG, Resch H, Krenn V. CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing. Acta Orthop 2017; 88:642-648. [PMID: 28787254 PMCID: PMC5694809 DOI: 10.1080/17453674.2017.1362774] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The most frequent cause of arthroplasty failure is aseptic loosening-often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone-implant interface. We analyzed CD3 quantities in SLIM depending on articulating materials and possible influences of proven material allergies on CD3 quantities. Patients and methods - 222 SLIM probes were obtained from revision surgeries of loosened hip and knee arthroplasties. SLIM cases were categorized according to the SLIM-consensus classification and to the particle algorithm. The CD3 quantities were analyzed immunohistochemically, quantified, and correlated to the particle types. Results - Metal-metal pairings showed the highest CD3 quantities (mean 1,367 counted cells). CD3 quantities of metal-polyethylene (mean 243), ceramic-polyethylene (mean 182), and ceramic-ceramic pairings (mean 124) were significantly smaller. Patients with contact allergy to implant materials had high but not statistically significantly higher CD3 quantities than patients without allergies. For objective assessment of the CD3 response as result of a pronounced inflammatory reaction with high lymphocytosis (adverse reaction), a defined CD3 quantity per high power field was established, the "CD3 focus score" (447 cells/0.3 mm2, sensitivity 0.92; specificity 0.90; positive predictive value 0.71; negative predictive value 0.98). Interpretation - The high CD3 quantities for metal-metal pairings may be interpreted as substrate for previously described adverse reactions that cause severe peri-implant tissue destruction and SLIM formation. It remains unclear whether the low CD3 quantities with only slight differences in the various non-metal-metal pairings and documented contact allergies to implant materials have a direct pathogenetic relevance.
Collapse
Affiliation(s)
- Felix Hopf
- Center for Histopathology and Molecular Pathology, Trier, Germany
| | - Peter Thomas
- Department of Dermatology and Allergologie, Ludwig-Maximilians-University (LMU), Munich, Germany
| | - Stefan Sesselmann
- Department of Orthopaedic Surgery, Friedrich-Alexander-University of Erlangen-Nuremberg, Germany,Correspondence:
| | - Marc N Thomsen
- Clinic of Orthopaedic Medicine and Emergency Surgery, Klinikum Mittelbaden Baden-Baden Balg, Baden-Baden, Germany
| | - Maximilian Hopf
- Center for Histopathology and Molecular Pathology, Trier, Germany
| | - Johannes Hopf
- Department of Orthopaedics and Traumatology, Johannes Gutenberg University, Mainz, Germany
| | | | - Herbert Resch
- University Hospital for Trauma Surgery and Sports Traumatology, Salzburg, Austria
| | - Veit Krenn
- Center for Histopathology and Molecular Pathology, Trier, Germany
| |
Collapse
|
25
|
Vaculova J, Gallo J, Hurnik P, Motyka O, Goodman SB, Dvorackova J. Low intrapatient variability of histomorphological findings in periprosthetic tissues from revised metal/ceramic on polyethylene joint arthroplasties. J Biomed Mater Res B Appl Biomater 2017; 106:2008-2018. [PMID: 29044940 DOI: 10.1002/jbm.b.33990] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2016] [Revised: 07/25/2017] [Accepted: 08/30/2017] [Indexed: 11/05/2022]
Abstract
The type of tissue response to implant by-products can be determined by examination of periprosthetic tissues. However, little is known about the most suitable location for tissue sampling. The main goal of this study was to evaluate the extent of variability in tissue response in relation to location of tissue sampling, implant fixation, age and sex in total joint arthroplasties with metal-on-polyethylene or ceramic-on-polyethylene bearing pairs. We processed 236 histology slides from 21 patients and focused on the association between the location of tissue samples and histological features. The presence of the synovial hyperplasia showed a significant association with the particular sampling site. A higher density of high endothelial cell venules was seen in the samples from around the joint, and polyethylene particles were more abundant in noncemented TJA but both findings did not show statistically significant association with the sampling site. The results showed a relatively small variance in the tissue response to prosthetic by-products among tissues sampled from the same patient. Our findings indicate that tissue samples retrieved from similar distance from around the TJA during the revision operation show comparable results of histological analysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2008-2018, 2018.
Collapse
Affiliation(s)
- Jana Vaculova
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic.,Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic
| | - Pavel Hurnik
- Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.,CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic
| | - Oldrich Motyka
- Nanotechnology Centre, VŠB - Technical University of Ostrava, Ostrava-Poruba, 708 33, Czech Republic
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford Medical Center Outpatient Clinic, Redwood City, CA, 94063
| | - Jana Dvorackova
- Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.,CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic
| |
Collapse
|
26
|
Di Laura A, Quinn PD, Panagiotopoulou VC, Hothi HS, Henckel J, Powell JJ, Berisha F, Amary F, Mosselmans JFW, Skinner JA, Hart AJ. The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue. Sci Rep 2017; 7:10952. [PMID: 28887488 PMCID: PMC5591307 DOI: 10.1038/s41598-017-11225-w] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 08/21/2017] [Indexed: 02/08/2023] Open
Abstract
The mechanisms of metal release from the articulation at the head cup bearing and the tapered junctions of orthopaedic hip implants are known to differ and the debris generated varies in size, shape and volume. Significantly less metal is lost from the taper junction between Cobalt-Chromium-Molybdenum (CoCrMo) and Titanium (Ti) components (fretting-corrosion dominant mechanism), when compared to the CoCrMo bearing surfaces (wear-corrosion dominant mechanism). Corrosion particles from the taper junction can lead to Adverse Reactions to Metal Debris (ARMD) similar to those seen with CoCrMo bearings. We used synchrotron methods to understand the modes underlying clinically significant tissue reactions to Co, Cr and Ti by analysing viable peri-prosthetic tissue. Cr was present as Cr2O3 in the corroded group in addition to CrPO4 found in the metal-on-metal (MoM) group. Interestingly, Ti was present as TiO2 in an amorphous rather than rutile or anatase physical form. The metal species were co-localized in the same micron-scale particles as result of corrosion processes and in one cell type, the phagocytes. This work gives new insights into the degradation products from metal devices as well as guidance for toxicological studies in humans.
Collapse
Affiliation(s)
- Anna Di Laura
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.
| | - Paul D Quinn
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom
| | - Vasiliki C Panagiotopoulou
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Johann Henckel
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Jonathan J Powell
- Biomineral Research Group, Dept Veterinary Medicine, University of Cambridge, Cambridge, United Kingdom
| | - Fitim Berisha
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Fernanda Amary
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - J Fred W Mosselmans
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom
| | - John A Skinner
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| |
Collapse
|
27
|
Abstract
A T cell-mediated hypersensitivity reaction has been reported in some patients with CoCrMo-based implants. However, the role of cobalt and chromium ions in this reaction remains unclear. The objective of the present study was to analyze the effects of Co2+ and Cr3+ in culture medium, as well as the effects of culture supernatants of macrophages exposed to Co2+ or Cr3+ , on the migration of lymphocytes. The release of cytokines/chemokines by macrophages exposed to Co2+ and Cr3+ was also analyzed. The migration of murine lymphocytes was quantified using the Boyden chamber assay and flow cytometry, while cytokine/chemokine release by J774A.1 macrophages was measured by ELISA. Results showed an ion concentration-dependent increase in TNF-α and MIP-1α release and a decrease in MCP-1 and RANTES release. Migration analysis showed that the presence of Co2+ (8 ppm) and Cr3+ (100 ppm) in culture medium increased the migration of T lymphocytes, while it had little or no effect on the migration of B lymphocytes, suggesting that Co2+ and Cr3+ can stimulate the migration of T but not B lymphocytes. Levels of T lymphocyte migration in culture medium containing Co2+ or Cr3+ were not statistically different from those in culture supernatants of macrophages exposed to Co2+ or Cr3+ , suggesting that the effects of the ions and chemokines were not additive, possibly because of ion interference with the chemokines and/or their cognate receptors. Overall, results suggest that Co2+ and Cr3+ are capable of stimulating the migration of T (but not B) lymphocytes in the absence of cytokines/chemokines, and could thereby contribute to the accumulation of more T than B lymphocytes in periprosthetic tissues of some patients with CoCrMo-based implants. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:916-924, 2017.
Collapse
Affiliation(s)
- Stephen J Baskey
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Eric A Lehoux
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5
| | - Isabelle Catelas
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada, K1N 6N5.,Department of Surgery, University of Ottawa, The Ottawa Hospital-General Campus, 501 Smyth Road, Ottawa, Ontario, Canada, K1H 8L6.,Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario, Canada, K1H 8M5
| |
Collapse
|
28
|
Xia Z, Ricciardi BF, Liu Z, von Ruhland C, Ward M, Lord A, Hughes L, Goldring SR, Purdue E, Murray D, Perino G. Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty. Nanomedicine: Nanotechnology, Biology and Medicine 2017; 13:1205-1217. [DOI: 10.1016/j.nano.2016.11.003] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Revised: 10/30/2016] [Accepted: 11/17/2016] [Indexed: 01/13/2023]
|
29
|
Abstract
Large-head metal-on-metal (MoM) bearings were re-popularised in the late 1990s with the introduction of modern hip resurfacing (HR), followed closely by large metal head total hip arthroplasty (THA). A worldwide increase in the use of MoM hip arthroplasty subsequently saw a sharp decline, due to serious complications. MoM was rapidly adopted in the early 2000s until medical device alerts were issued by government regulatory agencies and national and international organisations, leading to post-marketing surveillance and discontinuation of these implants. Guidelines for MoM hip implant follow-up differ considerably between regulatory authorities worldwide; this can in part be attributed to missing or conflicting evidence. The authors consider that the use of large-head MoM THA should be discontinued. MoM HR should be approached with caution and, when considered, should be used only in patients who meet all of the recommended selection criteria, which limits its indications considerably. The phased introduction of new prostheses should be mandatory in future. Close monitoring of outcomes and long-term follow-up is also necessary for the introduction of new prostheses.
Cite this article: van Lingen CP, Zagra LM, Ettema HB, Verheyen CC. Sequelae of large-head metal-on-metal hip arthroplasties: current status and future prospects. EFORT Open Rev 2016;1:345-353. DOI: 10.1302/2058-5241.1.160014.
Collapse
Affiliation(s)
| | | | - Harmen B Ettema
- Isala Clinics, Department of Orthopaedic Surgery and Traumatology, Zwolle, The Netherlands
| | - Cees C Verheyen
- Isala Clinics, Department of Orthopaedic Surgery and Traumatology, Zwolle, The Netherlands
| |
Collapse
|
30
|
Kwon YM, Tsai TY, Leone WA, Liow MHL. Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty. J Arthroplasty 2017; 32:996-1000. [PMID: 27776907 DOI: 10.1016/j.arth.2016.08.040] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 08/28/2016] [Accepted: 08/29/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Currently, no serum metal ion threshold exists to identify adverse tissue reactions in total hip arthroplasty (THA) patients with taper corrosion. Our study aims to investigate the sensitivity and specificity of serum metal ions in detecting taper corrosion related pseudotumors in patients with dual taper modular THA. METHODS A total of 148 patients with dual taper modular THA were investigated: (1) 90 patients with pseudotumors detected with metal artifact reduction sequence-magnetic resonance imaging (MARS-MRI) and (2) 58 patients without pseudotumors on MARS-MRI. Receiver operating characteristic curves were constructed to determine the sensitivity and specificity using different metal ion thresholds. The severity of intraoperative tissue damage was correlated with preoperative metal ion levels. RESULTS Pseudotumor was associated with higher cobalt (5.0 μg/L vs 3.7 μg/L, P < .01) and Co/Cr ratio (6.0 vs 3.7, P < .01). The sensitivity and specificity for cobalt level of 2.8 μg/L and Co/Cr ratio of 3.8 in detecting taper corrosion-related pseudotumors on MARS-MRI was 88% and 32% and 70% and 50%, respectively. Higher intraoperative tissue damage grades demonstrated significantly higher Co/Cr ratios (8.6 vs 3.4, P = .03). CONCLUSION Although metal ion levels alone should not be relied on as the sole parameter to determine revision surgery, cobalt level >2.8 μg/L and the Co/Cr ratio >3.8 are useful clinical diagnostic adjuncts in the systematic clinical evaluation for taper corrosion-related adverse tissue reactions in patients with dual modular taper THA.
Collapse
|
31
|
Lawrence H, Mawdesley AE, Holland JP, Kirby JA, Deehan DJ, Tyson-Capper AJ. Targeting Toll-like receptor 4 prevents cobalt-mediated inflammation. Oncotarget 2016; 7:7578-85. [PMID: 26840091 PMCID: PMC4884939 DOI: 10.18632/oncotarget.7105] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Accepted: 01/23/2016] [Indexed: 12/19/2022] Open
Abstract
Cobalt-chrome alloy is a widely used biomaterial in joint replacements, dental implants and spinal rods. Although it is an effective and biocompatible material, adverse reactions to metal debris (ARMD) have arisen in a minority of patients, particularly in those with metal-on-metal bearing hip replacements. There is currently no treatment for ARMD and once progressive, early revision surgery of the implant is necessary. Therapeutic agents to prevent, halt or reverse ARMD would therefore be advantageous. Cobalt ions activate Toll-like receptor 4 (TLR4), an innate immune receptor responsible for inflammatory responses to bacterial lipopolysaccharide (LPS) resulting in the production of pro-inflammatory cytokines and chemokines. We hypothesised that anti-TLR4 neutralising antibodies, reported to inhibit TLR4-mediated inflammation, could prevent the inflammatory response to cobalt ions in an in vitro macrophagecell culture model. This study shows that a monoclonal anti-TLR4 antibody inhibited cobalt-mediated increases in pro-inflammatory IL8, CCL20 and IL1A expression, as well as IL-8 secretion. In contrast, a polyclonal antibody did not prevent the effect of cobalt ions on either IL-8 or IL1A expression, although it did have a small effect on the CCL20 response. Interestingly, both antibodies inhibited cobalt-mediated neutrophil migration although the greater effect was observed with the monoclonal antibody. In summary our data shows that a monoclonal anti-TLR4 antibody can inhibit cobalt-mediated inflammatory responses while a polyclonal antibody only inhibits the effect of specific cytokines. Anti-TLR4 antibodies have therapeutic potential in ARMD although careful antibody design is required to ensure that the LPS response is preserved.
Collapse
Affiliation(s)
- Helen Lawrence
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
| | | | | | - John Andrew Kirby
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK
| | - David John Deehan
- Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, UK.,Musculoskeletal Services, Freeman Hospital, Newcastle upon Tyne, UK
| | | |
Collapse
|
32
|
Elmallah RK, Cherian JJ, Meneghini RM, Hozack WJ, Westrich GH, Mont MA. How to Approach a Recalled Dual Modular Hip Implant: An Update. J Arthroplasty 2016; 31:2646-2652. [PMID: 27542855 DOI: 10.1016/j.arth.2016.06.059] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Revised: 05/08/2016] [Accepted: 06/27/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of this study was to provide an update on the "Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant" (Pivec et al JOA 2014) publication. METHODS We performed a comprehensive review of the literature in English, with search terms referencing to the diagnosis, management, and outcomes of patients who underwent total hip arthroplasty with a recalled dual modular hip implant. RESULTS Based on this review and the new guidelines by the American Academy of Orthopedic Surgeons and the Hip Society, we propose an updated algorithm for the diagnosis and management of patients with these recalled implants. CONCLUSION When encountering patients with these prostheses, it is imperative to take a step-by-step approach to evaluate whether patients are having potential complications. We hope that this has further clarified the appropriate steps that need to be carried out when confronted with these recalled devices.
Collapse
Affiliation(s)
- Randa K Elmallah
- Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Jeffrey J Cherian
- Department of Orthopaedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania
| | - Robert M Meneghini
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - William J Hozack
- Department of Orthopedic surgery, Rothman Institute, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Geoffrey H Westrich
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Michael A Mont
- Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland
| |
Collapse
|
33
|
Liow MHL, Kwon YM. Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. Int Orthop 2016; 41:885-892. [PMID: 27761629 DOI: 10.1007/s00264-016-3305-1] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 09/25/2016] [Indexed: 12/12/2022]
Abstract
The potential advantages of contemporary MoM THA implants include less volumetric wear with subsequent reduction of polyethylene wear-induced osteolysis and greater component stability with use of large-diameter femoral heads. However, there have been concerns regarding significantly elevated revision rates in MoM THA due to MoM-related complications such as adverse local tissue reaction (pseudotumour) formation. The increased failure rate in MoM hip arthroplasty is associated with the generation of biologically active, nanometer sized metal particles from the MoM bearing surfaces and taper junctions, which result in the development of a localized, adverse periprosthetic soft tissue response. The focus of this article is to provide an update on (1) implant, surgical and patient factors associated with adverse local tissue reactions (pseudotumours) and (2) the clinical systematic evaluation and management of patients with MoM hip arthroplasty based on the currently available evidence. There should be a low threshold to conduct a systematic clinical evaluation of patients with MoM hip arthroplasty as early recognition and diagnosis will allow the initiation of prompt and appropriate treatment. As a symptomatic MoM total hip arthroplasty may have intrinsic and extrinsic causes, patients should be evaluated systematically, utilizing risk stratification algorithms. Although specialized laboratory tests such as metal ion levels and cross sectional imaging modalities such as MARS MRI can be used to facilitate clinical decision making, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. Further research is required to obtain a better understanding of implant and patient risk factors associated with tribocorrosion in MoM total hip arthroplasty.
Collapse
Affiliation(s)
- Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
34
|
Munir S, Oliver RA, Zicat B, Walter WL, Walter WK, Walsh WR. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016; 5:370-8. [PMID: 27608650 PMCID: PMC5017139 DOI: 10.1302/2046-3758.59.2000507] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 05/24/2016] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVES This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. RESULTS The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. CONCLUSION This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage.Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370-378. DOI: 10.1302/2046-3758.59.2000507.
Collapse
Affiliation(s)
- S Munir
- Prince of Wales Clinical School Level 1, Clinical Science Bldg, Prince of Wales Hospital Gate 6 Avoca Street Sydney, 2031 Australia
| | - R A Oliver
- Prince of Wales Clinical School Level 1, Clinical Science Bldg, Prince of Wales Hospital Gate 6 Avoca Street Sydney, 2031 Australia
| | - B Zicat
- Specialist Orthopaedic Group, Suite 1.08, Level One, 3 - 9 Gillies Street Wollstonecraft NSW 2065, Australia
| | - W L Walter
- Specialist Orthopaedic Group, Suite 1.08, Level One, 3 - 9 Gillies Street Wollstonecraft NSW 2065, Australia
| | - W K Walter
- Specialist Orthopaedic Group, Suite 1.08, Level One, 3 - 9 Gillies Street Wollstonecraft NSW 2065, Australia
| | - W R Walsh
- Prince of Wales Clinical School Level 1, Clinical Science Bldg, Prince of Wales Hospital Gate 6 Avoca Street Sydney, 2031 Australia
| |
Collapse
|
35
|
Koziara CR, Lombardo DJ, Petersen-Fitts GR, Jildeh TR, Morawa L. Effects of Cobalt and Chromium Levels Following Modular Hip Stem Total Hip Arthroplasty. Orthopedics 2016; 39:288-92. [PMID: 27337670 DOI: 10.3928/01477447-20160616-04] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Accepted: 05/09/2016] [Indexed: 02/03/2023]
Abstract
Due to the increased number of revision total hip arthroplasties (THAs) to correct pain secondary to fretting from modular hip stems, this study was conducted in an effort to correlate objective findings of serum cobalt (Co) levels, serum chromium (Cr) levels, and/or reactive tissue seen on metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) with a patient's need for revision THA. The study group comprised 66 patients, 18 of whom received MARS MRI. Serum Co levels, serum Cr levels, and standard numeric rating scale for pain were documented for all patients. Statistical analysis was then performed to determine whether there was a correlation between the aforementioned variables and the need for revision THA. Serum Cr levels were higher in patients with positive reactive tissue findings on MARS MRI, although this only approached significance (P=.083). Serum Co levels were higher in those undergoing revision THA, but this also only approached significance (P=.076). Pain scores were significantly different between those undergoing revision and those not (P<.001). It is the opinion of the authors that there is no objective finding in this study that can be used to identify patients who require revision THA secondary to fretting of a modular hip stem prosthesis. Only a patient's stated pain level can assist a surgeon in the decision-making process regarding the need for revision THA secondary to fretting. [Orthopedics.2016; 39(5):288-292.].
Collapse
|
36
|
Liow MHL, Urish KL, Preffer FI, Nielson GP, Kwon YM. Metal Ion Levels Are Not Correlated With Histopathology of Adverse Local Tissue Reactions in Taper Corrosion of Total Hip Arthroplasty. J Arthroplasty 2016; 31:1797-802. [PMID: 26923497 DOI: 10.1016/j.arth.2016.01.041] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 01/21/2016] [Accepted: 01/26/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The underlying biological mechanism in the formation of adverse local tissue reaction in taper corrosion of total hip arthroplasty (THA) remains unknown. This study evaluated whether there was a dose-dependent relationship between metal ion levels, intraoperative tissue damage and ALVAL (aseptic lymphocyte-dominated vasculitis-associated lesion) scores in dual taper THA patients who underwent revisions for taper corrosion. METHODS We performed a retrospective review of 31 dual taper THA patients who underwent revision surgery from May 2013 to October 2013. Preoperative serum metal ion levels, intraoperative tissue damage grading, and ALVAL scores were reviewed. Multivariate analysis was performed to determine if an association existed between metal ion levels, intraoperative tissue damage, and ALVAL scores. RESULTS Findings consistent with adverse local tissue reaction were found in all cases. We noted 10 patients with low, 8 with moderate, and 13 with high ALVAL scores, respectively. For intraoperative tissue damage, we recorded 2 (grade 1), 22 (grade 2) and 7 (grade 3) cases. Preoperatively, there was preferential elevation of serum cobalt (3.8 ng/mL, 2.3-17.0) compared to serum chromium (1.0 ng/mL, 0.2-5.8). There was no correlation between preoperative metal ion levels and intraoperative tissue damage (R = -0.06, P = .74) or ALVAL scores (R = -0.04, P = .481). There was also no correlation between intraoperative tissue damage and ALVAL score (R = -0.06, P = .73). CONCLUSION There was no significant correlation between ALVAL scores and prerevision surgery metal ion levels or intraoperative tissue damage, suggesting that the biological mechanism of histologic morphology cannot be solely attributed to elevated metal ion levels and is likely multifactorial, reflecting a complex interplay between implant and patient factors.
Collapse
Affiliation(s)
- Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Kenneth L Urish
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Frederic I Preffer
- Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Gunnlaugur P Nielson
- Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
37
|
Kwon YM. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision? J Arthroplasty 2016; 31:1385-9. [PMID: 27118353 DOI: 10.1016/j.arth.2016.01.074] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 01/27/2016] [Indexed: 02/01/2023] Open
Abstract
Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided.
Collapse
|
38
|
Gibon E, Amanatullah DF, Loi F, Pajarinen J, Nabeshima A, Yao Z, Hamadouche M, Goodman SB. The biological response to orthopaedic implants for joint replacement: Part I: Metals. J Biomed Mater Res B Appl Biomater 2016; 105:2162-2173. [PMID: 27328111 DOI: 10.1002/jbm.b.33734] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 04/19/2016] [Accepted: 06/01/2016] [Indexed: 12/12/2022]
Abstract
Joint replacement is a commonly performed, highly successful orthopaedic procedure, for which surgeons have a large choice of different materials and implant designs. The materials used for joint replacement must be both biologically acceptable to minimize adverse local tissue reactions, and robust enough to support weight bearing during common activities of daily living. Modern joint replacements are made from metals and their alloys, polymers, ceramics, and composites. This review focuses on the biological response to the different biomaterials used for joint replacement. In general, modern materials for joint replacement are well tolerated by the body as long as they are in bulk (rather than in particulate or ionic) form, are mechanically stable and noninfected. If the latter conditions are not met, the prosthesis will be associated with an acute/chronic inflammatory reaction, peri-prosthetic osteolysis, loosening and failure. This article (Part 1 of 2) is dedicated to the use of metallic devices in orthopaedic surgery including the associated biological response to metallic byproducts is a review of the basic science literature regarding this topic. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2162-2173, 2017.
Collapse
Affiliation(s)
- Emmanuel Gibon
- Department of Orthopaedic Surgery, Stanford University, Stanford, California.,Laboratoire de Biomécanique et Biomatériaux Ostéo-Articulaires - UMR CNRS 7052, Faculté de Médecine - Université Paris7, Paris, France.,Department of Orthopaedic Surgery, Hopital Cochin, APHP, Université Paris5, Paris, France
| | - Derek F Amanatullah
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Florence Loi
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Jukka Pajarinen
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Akira Nabeshima
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Zhenyu Yao
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| | - Moussa Hamadouche
- Department of Orthopaedic Surgery, Hopital Cochin, APHP, Université Paris5, Paris, France
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford University, Stanford, California
| |
Collapse
|
39
|
Mogensen SL, Jakobsen T, Christoffersen H, Krarup N. High Re-Operation Rates Using Conserve Metal-On-Metal Total Hip Articulations. Open Orthop J 2016; 10:41-8. [PMID: 27099640 PMCID: PMC4814723 DOI: 10.2174/1874325001610010041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 12/16/2015] [Accepted: 02/08/2016] [Indexed: 12/12/2022] Open
Abstract
Introduction: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two-center study. Materials and Methods: 108 CONSERVE® MOM THA were implanted in 92 patients between November 2005 and December 2010. Patients had at time of retrospective evaluation their journals reviewed for re-operations and adverse reactions. Results: 20 hips were re-operated (18.4%) at a mean follow up of 53 months. 4 pseudotumors were diagnosed at time of follow up but no substantiated link was made between adverse reactions and re-operations. Conclusion: The high re-operation rates found in this study raised concern about the usage of the MOM THA and subsequently lead to the termination of implantation of this MOM THA at the two orthopaedic departments.
Collapse
Affiliation(s)
- S L Mogensen
- Department of Orthopaedic Surgery, The Regional Hospital Viborg, Denmark
| | - T Jakobsen
- Department of Orthopaedic Surgery, The Regional Hospital Viborg, Denmark
| | - H Christoffersen
- Department of Orthopaedic Surgery, The Regional Hospital Thy, Denmark
| | - N Krarup
- Department of Orthopaedic Surgery, The Regional Hospital Viborg, Denmark
| |
Collapse
|
40
|
Krenn V, Perino G, Krenn VT, Wienert S, Saberi D, Hügle T, Hopf F, Huber M. [Histopathological diagnostic work-up of joint endoprosthesis-associated pathologies]. Hautarzt 2016; 67:365-72. [PMID: 26987961 DOI: 10.1007/s00105-016-3778-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Increasing classes of joint implants and the combination of materials results in increased and wear-associated pathologies. According to the revised consensus classification, the following types can be recognized at conventional histological examination: Type I, particle-induced type; Type II, infection type; Type III, combination type; Type IV, indifferent type; Type V arthrofibrotic type; Type VI, allergic/immunological/toxic adverse reactions and Type VII, bone pathologies. Wear particles are histopathologically characterized according to the Krenn particle algorithm which focuses on a descriptive identification of wear particles and the differentiation of other nonwear-related particles. Type VII is considered histologically when there is evidence of a perivascular/interstitial lymphocytic CD20- and CD3-positive infiltrate, presence of mast cells and eosinophils, and tissue necrosis/infarction associated with implant wear material. Since wear particle-induced toxicity cannot be differentiated with certainty from hypersensitivity/allergic reaction on histological examination, immunological-allergological and clinical data should be used as supplementary criteria for the differential diagnosis. Tissue sampling should be performed from periprosthetic soft tissue with location mapping and when feasible also from bone tissue. Additional information regarding the type of implant and clinical, radiological, immunological, and microbiology data should be available to the pathologist. Further immunohistochemical studies are recommended in the following settings: infection (CD15, CD20, CD68); prosthesis-associated arthrofibrosis (β‑catenin); allergic/immunologic/toxic adverse reactions (CD20, CD3, CD4, CD8, CD117 and for T‑cell characterization T‑bet, GATA-3, and FOXP3).
Collapse
Affiliation(s)
- V Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Max-Planck-Str. 5, 54296, Trier, Deutschland.
| | - G Perino
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, New York, USA
| | - V T Krenn
- Sigmund Freud PrivatUniversität Berlin, Berlin, Deutschland
| | - S Wienert
- VMscope GmbH Berlin, Berlin, Deutschland
| | - D Saberi
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Max-Planck-Str. 5, 54296, Trier, Deutschland
| | - T Hügle
- Universitätsspital Basel, Basel, Schweiz
| | - F Hopf
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Max-Planck-Str. 5, 54296, Trier, Deutschland
| | - M Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Österreich
| |
Collapse
|
41
|
Ricciardi BF, Nocon AA, Jerabek SA, Wilner G, Kaplowitz E, Goldring SR, Purdue PE, Perino G. Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases. BMC Clin Pathol 2016; 16:3. [PMID: 26924942 PMCID: PMC4769839 DOI: 10.1186/s12907-016-0025-9] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Accepted: 02/22/2016] [Indexed: 12/12/2022] Open
Abstract
Background Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. Methods Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. Results Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. Conclusions ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation.
Collapse
Affiliation(s)
- Benjamin F Ricciardi
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY USA
| | - Allina A Nocon
- Healthcare Research Institute, Hospital for Special Surgery, New York, NY USA
| | - Seth A Jerabek
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY USA
| | - Gabrielle Wilner
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - Elianna Kaplowitz
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - Steven R Goldring
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - P Edward Purdue
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - Giorgio Perino
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| |
Collapse
|
42
|
Krenn V, Hopf F, Thomas P, Thomsen M, Usbeck S, Boettner F, Müller S, Saberi D, Hügle T, Huber M, Scheuber L, Hopf J, Kretzer J. Supramakropartikuläres Polyethylen bei Entzündungen periprothetischer Membranen: Charakterisierung und Nomenklaturvorschlag. Orthopäde 2016; 45:256-65. [DOI: 10.1007/s00132-015-3194-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
43
|
Abstract
Clodronate is the father of bisphosphonates. For over three decades it has been subject of study in biological and clinical areas, proving to be an extremely interesting molecule from different points of view. It has been the first drug for osteoporosis that can be administered pulsatorily (once every 15 days or once a week). This, along with good tolerability, has been the first cause of its success, when there were no solid data in literature about its antifracture efficacy. There are three published studies that prove its antifracture effect: two by McCloskey published in 2004 and 2007 on BMR, and our study about fracture prevention in corticosteroids OP. In these studies a dose of 800 mg/day orally administered or 100 mg/week I.M. was used, and they are basically the same if you consider that clodronate absorption, orally administered, is on average 1.9%. However, a series of works where higher doses were used (1600 mg orally administered) with greater effectiveness on bone mass, especially in higher risk populations, lead us to consider the use of 200 mg i.m. formulation. First of all, we proved densitometric equivalence of 200 mg i.m./14 days and 100 mg i.m./week in a first study; then, in a second study, we proved a greater densitometric efficacy of 200 mg/week compared to 100 mg/week, clearer at femoral level, where the drug had not proven to prevent femoral fracture because of inadequate bone mass increase at that level. Moreover, as for ibandronate case, monthly dose was doubled compared to pivotal trial, in order to maximize the effects on femoral bone mass and therefore prevent femoral fractures. Consequently, on the basis of the risk envelope, whether it is identified according to BMD and the presence of one risk factor at least or more correctly identified through risk chart (FRAX or DeFRA), you can put forward a differential use of 100 mg i.m. and 200 mg i.m., weekly, "off-label" or every 14 days, adjusting doses in relation to fracture risk and painful symptoms gravity, as well as improving its ease of use and therefore assist compliance. Common experience and clinical and biological works have proved that clodronate has an analgesic effect that can be increased by doubling the doses. The analgesic effect is present not only with patients with fractures, but also with patients suffering from osteoarthritis or arthritis. Therefore, the drug would fit well in the therapeutic program of rheumatic patient, also because of its symptomatic effects. Clodronate at small doses (2 mg) could also have protective effects on cartilage (introduction of intra-articular formulation is expected) and at 10-100 fold higher doses it has certainly anti-inflammatory effects and more specifically antimacrophage and anticytokine effects (IL-1, IL-6, TNFalpha, PGE). These effects are amplified by putting clodronate in monolayer liposomes. This drug, therefore, has to be considered as adjuvant in arthritis therapy, whose origin can be linked to a strong osteoclastic activation caused by an increase of cytokines and the RANKL/OPG relationship. It is clear that clodronate can work on cytokine at first and on osteoclastic effector in the end. The drug has been used "off-label" for decades intravenously in complex regional pain syndrome (CRPS type 1) in relation to schemes that change according to different Authors and according to cumulative doses ranging from 3 to 5 g. The introduction on the market of the 200 mg i.m. formulation could allow to get more practical but equally effective schemes. For example, we used this scheme: 200 mg/day for 10 days and then 200 mg every other day for 20 days (cumulative dose of 4 g in a month). Said scheme can be repeated in the following months in particular cases. Results, as for efficacy and lack of relapses, show that clodronate is the leader drug for this syndrome. In recent years, relationship between costs and benefits has started to matter, especially after the creation of some algorithms, such as FRAX, that let us choose patients with a higher fracture risk in 10 years, and after pharmaceutic-economic models that let us calculate FRAX intervention threshold, on the basis of drug price and monitoring, antifracture efficacy, quality of life and how much a community can or wants to spend. In this respect, a sub-analysis of McCloskey's study on people over the age of 75, conducted on 3974 subjects, shows that clodronate is more efficient with patients with a higher fracture risk, calculated according to FRAX. Furthermore, another study by McCloskey revealed that, for a 100-pound/year drug (very similar to clodronate), 'cost effective' intervention threshold is about 7-10%. In conclusion, clodronate prevents fractures, decrease osteo-articular pain, is easy to handle, tolerable and had a great cost/benefit relationship.
Collapse
Affiliation(s)
- Bruno Frediani
- Medical and Surgical Science and Neuroscience Department, Rheumatology Section, University of Siena, O.U. of Osteo-Articular Diagnostic Procedures, Siena, Italy
| | - Ilaria Bertoldi
- Medical and Surgical Science and Neuroscience Department, Rheumatology Section, University of Siena, O.U. of Osteo-Articular Diagnostic Procedures, Siena, Italy
| |
Collapse
|
44
|
Kolatat K, Perino G, Wilner G, Kaplowitz E, Ricciardi BF, Boettner F, Westrich GH, Jerabek SA, Goldring SR, Purdue PE. Adverse local tissue reaction (ALTR) associated with corrosion products in metal-on-metal and dual modular neck total hip replacements is associated with upregulation of interferon gamma-mediated chemokine signaling. J Orthop Res 2015; 33:1487-97. [PMID: 25940887 DOI: 10.1002/jor.22916] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Accepted: 03/27/2015] [Indexed: 02/04/2023]
Abstract
Adverse local tissue reactions (ALTR) associated with tribocorrosion following total hip arthroplasty (THA) have become a significant clinical concern in recent years. In particular, implants featuring metal-on-metal bearing surfaces and modular femoral stems have been reported to result in elevated rates of ALTR. These tribocorrosion-related tissue reactions are characterized by marked necrosis and lymphocytic infiltration, which contrasts sharply with the macrophagic and foreign body giant cell inflammation associated with polyethylene wear particle induced peri-implant osteolysis. In this study, we characterize tribocorrosion-associated ALTR at a molecular level. Gene expression profiling of peri-implant tissue around failing implants identifies upregulation of numerous inflammatory mediators in ALTR, including several interferon gamma inducible factors, most notably the chemokines MIG/CXCL9 and IP-10/CXCL10. This expression profile is distinct from that associated with polyethylene wear induced osteolysis, which is characterized by induction of markers of alternative macrophage activation, such as chitotriosidase (CHIT-1). Importantly, MIG/CXCL9 and IP-10/CXCL10 are also elevated at the protein level in the synovial fluid and, albeit more moderately, the serum, of ALTR patients, raising the possibility that these factors may serve as circulating biomarkers for the early detection of ALTR in at-risk patients.
Collapse
|