1
|
International review of blood donation nucleic acid amplification testing. Vox Sang 2024; 119:315-325. [PMID: 38390819 DOI: 10.1111/vox.13592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 01/01/2024] [Accepted: 01/02/2024] [Indexed: 02/24/2024]
Abstract
BACKGROUND AND OBJECTIVES Nucleic acid amplification testing (NAT), in blood services context, is used for the detection of viral and parasite nucleic acids to reduce transfusion-transmitted infections. This project reviewed NAT for screening blood donations globally. MATERIALS AND METHODS A survey on NAT usage, developed by the International Society of Blood Transfusion Working Party on Transfusion-transmitted Infectious Diseases (ISBT WP-TTID), was distributed through ISBT WP-TTID members. Data were analysed using descriptive statistics. RESULTS Forty-three responses were received from 32 countries. Increased adoption of blood donation viral screening by NAT was observed over the past decade. NAT-positive donations were detected for all viruses tested in 2019 (proportion of donations positive by NAT were 0.0099% for human immunodeficiency virus [HIV], 0.0063% for hepatitis C virus [HCV], 0.0247% for hepatitis B virus [HBV], 0.0323% for hepatitis E virus [HEV], 0.0014% for West Nile virus [WNV] and 0.00005% for Zika virus [ZIKV]). Globally, over 3100 NAT-positive donations were identified as NAT yield or solely by NAT in 2019 and over 22,000 since the introduction of NAT, with HBV accounting for over half. NAT-positivity rate was higher in first-time donors for all viruses tested except WNV. During 2019, a small number of participants performed NAT for parasites (Trypanosoma cruzi, Babesia spp., Plasmodium spp.). CONCLUSION This survey captures current use of blood donation NAT globally. There has been increased NAT usage over the last decade. It is clear that NAT contributes to improving blood transfusion safety globally; however, there is a need to overcome economic barriers for regions/countries not performing NAT.
Collapse
|
2
|
An international review of the characteristics of viral nucleic acid-amplification testing (NAT) reveals a trend towards the use of smaller pool sizes and individual donation NAT. Vox Sang 2024. [PMID: 38516962 DOI: 10.1111/vox.13617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/19/2024] [Accepted: 03/03/2024] [Indexed: 03/23/2024]
Abstract
BACKGROUND AND OBJECTIVES Nucleic acid-amplification testing (NAT) is used for screening blood donations/donors for blood-borne viruses. We reviewed global viral NAT characteristics and NAT-yield confirmatory testing used by blood operators. MATERIALS AND METHODS NAT characteristics and NAT-yield confirmatory testing used during 2019 was surveyed internationally by the International Society of Blood Transfusion Working Party Transfusion-Transmitted Infectious Diseases. Reported characteristics are presented herein. RESULTS NAT was mainly performed under government mandate. Human immunodeficiency virus (HIV), hepatitis C virus (HCV) and hepatitis B virus (HBV) NAT was performed on all donors and donation types, while selective testing was reported for West Nile virus, hepatitis E virus (HEV), and Zika virus. Individual donation NAT was used for HIV, HCV and HBV by ~50% of responders, while HEV was screened in mini-pools by 83% of responders performing HEV NAT. Confirmatory testing for NAT-yield samples was generally performed by NAT on a sample from the same donation or by NAT and serology on samples from the same donation and a follow-up sample. CONCLUSION In the last decade, there has been a trend towards use of smaller pool sizes or individual donation NAT. We captured characteristics of NAT internationally in 2019 and provide insights into confirmatory testing approaches used for NAT-yields, potentially benefitting blood operators seeking to implement NAT.
Collapse
|
3
|
RHD-negative red cells may be avoided for patients with ambiguous serologic typing for the RHD antigen. Transfusion 2024; 64:281-288. [PMID: 38142051 DOI: 10.1111/trf.17691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/05/2023] [Accepted: 12/06/2023] [Indexed: 12/25/2023]
Abstract
BACKGROUND AND OBJECTIVES Serologic typing with monoclonal anti-D is mandatory for RHD antigen determination before transfusion, but due to aberrant (weak or partial) variants of RHD, results may be ambiguous and molecular RHD-typing is required. Before that, RHD-negative (RHD -) red blood cells concentrates (RBCs) shall be transfused to avoid anti-D formation, which probably leads to wastage of RHD - RBCs. STUDY DESIGN AND METHODS: All patients with ambiguous results in serologic RHD-typing and molecular RHD-typing were assessed retrospectively. The proportions of patients at risk for anti-D formation and the proportion of RHD - RBCs transfused unnecessarily were evaluated for the following transfusion strategies: (1) RHD-positive (RHD + )RBCs for all patients, (2) RHD + RBCs for patients with at least 2+ reaction with anti-D, (3) RHD + RBCs for patients with C and/or E in their RHCE-phenotype, (4) RHD + RBCs for patients with C and/or E and at least 2+ reaction, and (5) RHD - RBCs for all patients. RESULTS A total of 112 patients were included. Most had weak D type 1-3 and a minority had other, rare RHD variants. The risk of anti-D formation was 4.5%, 2.9%, 1.8%, 1.0%, and 0% for strategies 1-5, respectively. The proportion of RHD - RBCs transfused unnecessarily was 0%, 49.5%, 0.9%, 50.5%, and 95.5%. CONCLUSION Transfusing patients with a C and/or E in their RHCE-phenotype with RHD + RBCs resulted in a very low risk of immunization while avoiding wastage of RHD - RBCs. Therefore, this strategy should be used for some patients with ambiguous results in serologic RHD-typing and pending results of molecular RHD-typing.
Collapse
|
4
|
Serum reactivity in dermatitis herpetiformis: an international multicentre study. Clin Exp Dermatol 2023; 49:53-57. [PMID: 37793183 DOI: 10.1093/ced/llad319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 10/06/2023]
Abstract
BACKGROUND Dermatitis herpetiformis (DH) is a rare gluten-induced skin disorder characterized predominantly by IgA autoantibodies against endomysium, tissue transglutaminase (TG2/tTG), epidermal transglutaminase (TG3/eTG) and deamidated gliadin. To date, circulating autoantibody reactivity has not been systematically described. OBJECTIVES Characterization of serum reactivities in DH. METHODS This multicentre international study analysed sera from 242 patients with DH taken at the time of initial diagnosis. DH-specific IgA and IgG serum autoantibodies were analysed by indirect immunofluorescence (IF) on monkey oesophagus, and by enzyme-linked immunosorbent assay (ELISA) based on recombinant TG2/tTG, TG3/eTG and deamidated gliadin (GAF3X). RESULTS IgA indirect IF microscopy on monkey oesophagus revealed the highest reactivity (84.3%; specificity 100%) followed by IgA TG2/tTG ELISA (78.5%, specificity 99.0%), IgA TG3/eTG ELISA (72.7%, specificity 95.0%) and IgA GAF3X ELISA (69.0%, specificity 98.5%). CONCLUSIONS Serum IgA and IgG autoantibodies against endomysium, TG2/tTG, TG3/eTG and deamidated gliadin are highly prevalent in DH. Indirect IF microscopy on monkey oesophagus (IgA) provides the highest diagnostic accuracy that can be further enhanced by 4.5% when combined with IgA TG2/tTG ELISA.
Collapse
|
5
|
Correction to: Role of prothrombin 19,911 A > G polymorphism, blood group and male gender in patients with venous thromboembolism: results of a german cohort study. J Thromb Thrombolysis 2023:10.1007/s11239-023-02809-7. [PMID: 37060522 DOI: 10.1007/s11239-023-02809-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/10/2023] [Indexed: 04/16/2023]
|
6
|
Monitoring the SARS-CoV-2 Pandemic: Prevalence of Antibodies in a Large, Repetitive Cross-Sectional Study of Blood Donors in Germany—Results from the SeBluCo Study 2020–2022. Pathogens 2023; 12:pathogens12040551. [PMID: 37111436 PMCID: PMC10144823 DOI: 10.3390/pathogens12040551] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/17/2023] [Accepted: 03/27/2023] [Indexed: 04/05/2023] Open
Abstract
SARS-CoV-2 serosurveillance is important to adapt infection control measures and estimate the degree of underreporting. Blood donor samples can be used as a proxy for the healthy adult population. In a repeated cross-sectional study from April 2020 to April 2021, September 2021, and April/May 2022, 13 blood establishments collected 134,510 anonymised specimens from blood donors in 28 study regions across Germany. These were tested for antibodies against the SARS-CoV-2 spike protein and nucleocapsid, including neutralising capacity. Seroprevalence was adjusted for test performance and sampling and weighted for demographic differences between the sample and the general population. Seroprevalence estimates were compared to notified COVID-19 cases. The overall adjusted SARS-CoV-2 seroprevalence remained below 2% until December 2020 and increased to 18.1% in April 2021, 89.4% in September 2021, and to 100% in April/May 2022. Neutralising capacity was found in 74% of all positive specimens until April 2021 and in 98% in April/May 2022. Our serosurveillance allowed for repeated estimations of underreporting from the early stage of the pandemic onwards. Underreporting ranged between factors 5.1 and 1.1 in the first two waves of the pandemic and remained well below 2 afterwards, indicating an adequate test strategy and notification system in Germany.
Collapse
|
7
|
Can advanced edge enhancement software improve image quality to visualise tubes, catheters and wires in digital chest radiographs? Radiography (Lond) 2023; 29:165-170. [PMID: 36395686 DOI: 10.1016/j.radi.2022.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 10/16/2022] [Accepted: 10/18/2022] [Indexed: 11/15/2022]
Abstract
INTRODUCTION This study aimed to test whether Advanced Edge Enhancement (AEE) software could improve the localisation of tubes, catheters or wires, while also affecting the overall image quality in chest x-rays (CXR). METHODS In total, 50 retrospective CXRs were included. All images were obtained utilising the Canon X-ray system (CANON/Arcoma Precision T3 DR System, Canon Europe, Amsterdam, NL) with a CXDI-810C wireless detector. A clinical image, plus three additional AEE algorithms were applied using post processing (two intensity variations 1 and 4) on all CXRs totalling 350 different images. Three radiologists evaluated the images using a subjective Absolute Visual Grading Analysis (VGA). The clinical images used in post processing were not applied as reference in the analysis. Each radiologist graded the images separately in a randomized order, with a score of three indicating suitability for diagnostic assessment. RESULTS The three AEE algorithms contributed to an overall improvement (average 16-49%) in visualisation of tube, catheter or wire on CXR images. The Mann-Whitney U tests showed a statistically significant (p < 0.05) improvement in contrast resolution and sharpness, indicating an increased ability to differentiate tubes, wires or catheters tips from surrounding tissues. For the noise criterion, not applying any AEE algorithm showed a significantly higher homogeneity in soft tissue (p < 0.001), reducing the ability to visualise soft tissue. The high-intensity catheter algorithm was the only algorithm to achieve a statistically significant (p = 0.017) increase in the ability to differentiate pulmonary tissues of similar density. CONCLUSION An overall improvement in the visualisation of tube, catheter and wire placement was obtained using the three AEE-algorithms. The bone and catheter algorithms showed the highest consistency, with the small structure algorithm underperforming in resolution and low contrast resolution. In general, image noise increased regardless of algorithm type or applied intensity. The AEE-algorithms should therefore be seen as a supplementary tool to the clinical image protocol, while having the potential to improve image quality to specific clinical situations. IMPLICATIONS FOR PRACTICE AEE filtered images appear to be a supplement to the current practice of using CXRs in the diagnosis in placement of catheters, tubes and wires in the chest region. The use of AEE-algorithms has the potential to improve the daily work in clinical practice, which serves the basis for further investigation of its effect on radiographic practices.
Collapse
|
8
|
Completing the Donor History Questionnaire before the Donation Visit Can Improve Blood Safety. Transfus Med Hemother 2022; 49:306-314. [PMID: 37969867 PMCID: PMC10642529 DOI: 10.1159/000522101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 01/20/2022] [Indexed: 11/17/2023] Open
Abstract
Background and Objectives In Germany, the donor history questionnaire (DHQ) is traditionally filled in at the donation center to avoid any influence of others. Since March 2020, it has been suggested to donors to answer the DHQ already at home and to call if they have any concerns to reduce the number of ineligible donors on-site during the COVID-19 pandemic. Materials and Methods We evaluated the rate of ineligible donors before and after March 2020. Additionally, an anonymous online survey asking for the donors' attitude towards the DHQ was performed. It included questions on whether and for what reason the DHQ had been answered incorrectly in the past. Results The rate of ineligible donors decreased by 27% (from 7.1% to 5.2%). In total, 5,556 of 10,252 invited donors completed the survey (54.2%). 88.6% reported either going through the DHQ at home or knowing all questions from their previous donations. 444 donors (8.0%) had at least once postponed a donation after reading the DHQ at home. 68 donors (1.2%) admitted having intentionally provided false answers in the past (9 at home, 43 on-site, 14 both, 2 unknown). Not wanting to be rejected once arriving at the donation center was an important motivation for 42% of donors answering incorrectly on-site. Details on 46 incorrect answers were provided: only 17 had no influence on donor eligibility or product quality. In 5 cases, some blood products might have had impaired quality. Truthful answers to 17 questions would have led to deferral, mostly due to increased risk for unrecognized viral infections transmitted by sexual contacts. For a further 7 questions, there was insufficient information available to determine possible consequences. Asked about their general opinion, 753 (13.6%) of all donors estimated the risk of incorrect answers being greater on-site, while 239 (4.3%) presumed an increased risk at home. Conclusion Answering the DHQ prior to a donation visit prevented ineligible donors from visiting the donation center. Furthermore, it might improve honesty, as the discomfort of being deferred after arriving at the donation center was an important reason to answer incorrectly. Overall, there was no increased risk of donor or product safety, and potentially even a benefit.
Collapse
|
9
|
Validation of a predictive model for identifying an increased risk for recurrence in adolescents and young adults with a first provoked thromboembolism. Blood Cells Mol Dis 2022; 94:102651. [PMID: 35051688 DOI: 10.1016/j.bcmd.2022.102651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 01/08/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND To develop and validate a predictive model to determinate patients at increased risk to suffer from recurrence following a first provoked deep vein thrombosis (VTE). METHODS Predictive variables, i.e. male sex [1 point], inherited thrombophilia (IT) status (none [0 points], single [1 point], combined variants [2 points]), blood group non-0, and age at first VTE onset were included into a risk assessment model, which was derived in 511 patients and then validated in 509 independent subjects. RESULTS VTE recurrence risk score (maximum 4 points, range 0-3) was below two for patients scored as low-risk (LRS) and ≥2 for patients at high-risk (HRS). Within a median time of 3 years after withdrawal of anticoagulation (AC) recurrence rate in LRG (derivation) was 11.8% versus 26.0% in HRS (p < 0.001). In the validation cohort within 2.2 years the recurrence rate was 9.8% in LRS versus 30.1% in HRS (p < 0.001). In multivariable analysis adjusted for age at first VTE and blood group the recurrent risk in HRS was significantly increased compared with the LRS (derivation: hazard/95% confidence interval: 3.7/1.75-7.91; validation: 4.7/2.24-9.81; combined 5.2/1.92-13.9). Model specificity (sensitivity) was 79.0% (52.0%) in the derivation cohort compared with 78.0% (43.0%) in the validation group. In conclusion, in the prediction model presented here the risk of VTE recurrence was associated with male gender and combined ITs. Based on the negative predictive value calculated the model may identify patients with a first provoked VTE not being at risk for recurrence.
Collapse
|
10
|
Differences in Immunogenicity of Three Different Homo- and Heterologous Vaccination Regimens against SARS-CoV-2. Vaccines (Basel) 2022; 10:vaccines10050649. [PMID: 35632405 PMCID: PMC9145236 DOI: 10.3390/vaccines10050649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/15/2022] [Accepted: 04/18/2022] [Indexed: 12/10/2022] Open
Abstract
Background: Due to findings on adverse reactions and clinical efficacy of different vaccinations against SARS-CoV-2, the administration of vaccination regimens containing both adenoviral vector vaccines and mRNA-based vaccines has become common. Data are still needed on the direct comparison of immunogenicity for these different regimens. Methods: We compared markers for immunogenicity (anti-S1 IgG/IgA, neutralizing antibodies, and T-cell response) with three different vaccination regimens (homologous ChAdOx1 nCoV-19 (n = 103), or mixture of ChAdOx1 nCoV-19 with mRNA-1273 (n = 116) or BNT162b2 (n = 105)) at two time points: the day of the second vaccination as a baseline and 14 days later. Results: All examined vaccination regimens elicited measurable immune responses that were significantly enhanced after the second dose. Homologous ChAdOx1 nCoV-19 was markedly inferior in immunogenicity to all other examined regimens after administration of the second dose. Between the heterologous regimens, mRNA-1273 as second dose induced greater antibody responses than BNT162b2, with no difference found for neutralizing antibodies and T-cell response. Discussion: While these findings allow no prediction about clinical protection, from an immunological point of view, vaccination against SARS-CoV-2 with an mRNA-based vaccine at one or both time points appears preferable to homologous vaccination with ChAdOx1 nCoV-19. Whether or not the demonstrated differences between the heterologous regimens are of clinical significance will be subject to further research.
Collapse
|
11
|
Kinetics of the Antibody Response to Boostering With Three Different Vaccines Against SARS-CoV-2. Front Immunol 2022; 13:811020. [PMID: 35126395 PMCID: PMC8807650 DOI: 10.3389/fimmu.2022.811020] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 01/03/2022] [Indexed: 12/14/2022] Open
Abstract
BackgroundHeterologous vaccinations against SARS-CoV-2 with ChAdOx1 nCoV-19 and a second dose of an mRNA-based vaccine have been shown to be more immunogenic than homologous ChAdOx1 nCoV-19. In the current study, we examined the kinetics of the antibody response to the second dose of three different vaccination regimens (homologous ChAdOx1 nCoV-19 vs. ChAdOx1 nCoV-19 + BNT162b2 or mRNA-1273) against SARS-CoV-2 in a longitudinal manner; whether there are differences in latency or amplitude of the early response and which markers are most suitable to detect these responses.MethodsWe performed assays for anti-S1 IgG and IgA, anti-NCP IgG and a surrogate neutralization assay on serum samples collected from 57 participants on the day of the second vaccination as well as the following seven days.ResultsAll examined vaccination regimens induced detectable antibody responses within the examined time frame. Both heterologous regimens induced responses earlier and with a higher amplitude than homologous ChAdOx1 nCoV-19. Between the heterologous regimens, amplitudes were somewhat higher for ChAdOx1 nCoV-19 + mRNA-1273. There was no difference in latency between the IgG and IgA responses. Increases in the surrogate neutralization assay were the first changes to be detectable for all regimens and the only significant change seen for homologous ChAdOx1 nCoV-19.DiscussionBoth examined heterologous vaccination regimens are superior in immunogenicity, including the latency of the response, to homologous ChAdOx1 nCoV-19. While the IgA response has a shorter latency than the IgG response after the first dose, no such difference was found after the second dose, implying that both responses are driven by separate plasma cell populations. Early and steep increases in surrogate neutralization levels suggest that this might be a more sensitive marker for antibody responses after vaccination against SARS-CoV-2 than absolute levels of anti-S1 IgG.
Collapse
|
12
|
Emerging Pathogens: Novel and Well-Known Infectious Threats in Transfusion Medicine. Transfus Med Hemother 2022; 49:189-191. [PMID: 36159961 PMCID: PMC9421685 DOI: 10.1159/000525327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 05/30/2022] [Indexed: 11/29/2022] Open
|
13
|
Donors for SARS-CoV-2 Convalescent Plasma for a Controlled Clinical Trial: Donor Characteristics, Content and Time Course of SARS-CoV-2 Neutralizing Antibodies. Transfus Med Hemother 2021; 48:137-147. [PMID: 34177417 PMCID: PMC8216018 DOI: 10.1159/000515610] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/28/2021] [Indexed: 12/15/2022] Open
Abstract
Background Convalescent plasma is one of the treatment options for COVID-19 which is currently being investigated in many clinical trials. Understanding of donor and product characteristics is important for optimization of convalescent plasma. Methods Patients who had recovered from COVID-19 were recruited as donors for COVID-19 convalescent plasma (CCP) for a randomized clinical trial of CCP for treatment of severe COVID-19 (CAPSID Trial). Titers of neutralizing antibodies were measured by a plaque-reduction neutralization test (PRNT). Correlation of antibody titers with host factors and evolution of neutralizing antibody titers over time in repeat donors were analysed. Results A series of 144 donors (41% females, 59% males; median age 40 years) underwent 319 plasmapheresis procedures providing a median collection volume of 850 mL and a mean number of 2.7 therapeutic units per plasmapheresis. The majority of donors had a mild or moderate course of COVID-19. The titers of neutralizing antibodies varied greatly between CCP donors (from <1:20 to >1:640). Donor factors (gender, age, ABO type, body weight) did not correlate significantly with the titer of neutralizing antibodies. We observed a significant positive correlation of neutralization titers with the number of reported COVID-19 symptoms and with the time from SARS-CoV-2 diagnosis to plasmapheresis. Neutralizing antibody levels were stable or increased over time in 58% of repeat CCP donors. Mean titers of neutralizing antibodies of first donation and last donation of repeat CCP donors did not differ significantly (1:86 at first compared to 1:87 at the last donation). There was a significant correlation of neutralizing antibodies measured by PRNT and anti-SARS-CoV-2 IgG and IgA antibodies which were measured by ELISA. CCP donations with an anti-SARS-CoV-2 IgG antibody content above the 25th percentile were substantially enriched for CCP donations with higher neutralizing antibody levels. Conclusion We demonstrate the feasibility of collection of a large number of CCP products under a harmonized protocol for a randomized clinical trial. Titers of neutralizing antibodies were stable or increased over time in a subgroup of repeat donors. A history of higher number of COVID-19 symptoms and higher levels of anti-SARS-CoV-2 IgG and IgA antibodies in immunoassays can preselect donations with higher neutralizing capacity.
Collapse
|
14
|
The influence of a novel edge enhancement software on image quality of DR hand images of patients with rheumatoid arthritis. Radiography (Lond) 2021; 27:877-882. [PMID: 33676836 DOI: 10.1016/j.radi.2021.02.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 02/01/2021] [Accepted: 02/10/2021] [Indexed: 11/16/2022]
Abstract
INTRODUCTION This study aimed to evaluate the effects of a newly developed Advanced Edge Enhancement software (AEE) (Canon Europe, Amsterdam, NL) on image quality (IQ) of Digital Radiography (DR) hand images focusing on rheumatoid arthritis (RA). METHODS AND MATERIALS Fifty posterior-anterior hand images with or suspected for RA were collected. For each of the 50 images, six copies were made with each their AEE algorithm settings. A total of 330 images (30 images iterated) were evaluated using relative Visual Grading Analysis (VGA) by three observers and combined into a VGA Score (VGAS). Second, 50 images of a technical Contrast Detail Radiography Phantom (CDRAD) was produced with three different AEE software settings, each at level 1,5 and without the AEE software yielding 350 CDRAD images. All images was analysed by the CDRAD Analyser and included for an objective analysis of the AEE software. RESULTS The VGA study showed a significant difference in image quality between a standard image and images with AEE software applied. The average VGA score of the AEE software was better than the standard images (interval between 0.2 and 0.9). The AEE algorithms at level 5 scored significantly lower for noise but significantly higher for spatial resolution, sharpness and contrast in the VGA. The CDRAD images showed that all AEE algorithms had a statistically significant improvement for level 1 and deterioration for level 5 compared to the standard image. CONCLUSION Overall the AEE algorithm: small structure level 1 showed an improvement of all IQ criteria in the VGA and a better technical IQ. IMPLICATIONS FOR PRACTICE The AEE software ought to be considered as a useful addition to the current software, possibly enabling visualisation of structures currently visible.
Collapse
|
15
|
Two Novel Variants in the Protein S Gene PROS1 Are Associated with Protein S Deficiency and Thrombophilia. Acta Haematol 2020; 144:222-226. [PMID: 32653888 DOI: 10.1159/000508525] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 05/07/2020] [Indexed: 11/19/2022]
Abstract
Protein S (PS) is an important anticoagulant. Its main function is to act as a non-enzymatical cofactor of activated protein C. PS deficiency is defined as low plasma levels of PS and/or loss of function associated with variable risk of venous thromboembolism (VTE). We report 2 novel variants in the PS gene (PROS1) which are associated with PS deficiency and severe thrombophilic diathesis in 2 patients. Patient 1 suffered from 3 VTE events, including a spontaneous VTE at the age of 19. Patient 2 suffered from 2 provoked VTE events. In both patients decreased plasma levels of PS antigen as well as decreased PS activity were found. Gene sequencing results showed a heterozygous deletion of 8 base pairs (c.938_945delTAAAATTT, p.Leu313Serfs13*) in exon 9 of the PROS1 gene in patient 1 and a missense variant (c.1613C>T, p.Ser538Phe) in patient 2. Due to the clinically proven history of recurrent VTE events in both patients, genetic testing of first-degree relatives is discussed.
Collapse
|
16
|
Prevalence of antibodies against Hepatitis D virus (HDV) in blood donors in Northern Germany. Transfus Apher Sci 2020; 59:102721. [DOI: 10.1016/j.transci.2020.102721] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/05/2019] [Accepted: 12/23/2019] [Indexed: 12/31/2022]
|
17
|
Impacts of platelet-rich fibrin and platelet-rich plasma on primary osteoblast adhesion onto titanium implants in a bisphosphonate in vitro model. J Oral Pathol Med 2019; 48:943-950. [PMID: 31400171 DOI: 10.1111/jop.12944] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 05/15/2019] [Accepted: 08/04/2019] [Indexed: 11/30/2022]
Abstract
BACKGROUND Osteoblast adhesion is a crucial step in osseointegration of dental implants and can be influenced by modification of implant surface or the addition of bioactive agents. Bisphosphonates affect bone turnover, attenuating bone healing in implants patients. PRP and PRF are sources of growth factors involved in osteoblast adhesion, improving subsequent bone healing. The aim of the study was to investigate the impacts of PRP and PRF on adhesion of bisphosphonate-pretreated osteoblasts on titanium implant surfaces using the cell-count wash assay, the MTT-assay as well as real-time-cell analyser assay and scanning electronic microscopy. METHODS Titanium implants were colonised for 24 hours with osteoblasts and zolendronic acid, PRP or PRF in different combinations. Afterwards, primary osteoblast adhesion was evaluated by counting the number of attached cells using a wash-assay cell analysis. Scanning electronic microscopy was performed and evaluated semi-quantitatively to assess the influence of the different groups on the ultrastructural cell morphology, such as cell size and shape as well as length and number of filopodia. RESULTS Zoledronic acid led to a decrease of osteoblast adherence onto implant surface. This effect was reversed by adding PRP or PRF. Scanning electronic microscopy showed that both PRP and PRF increased number and length of filopodia in adherent osteoblasts. CONCLUSIONS Zoledronic acid decreased osteoblast adhesion on implant surfaces, and PRF as well as PRP increased primary adhesion of zoledronic acid-treated osteoblasts on implant surfaces in vitro. Therefore, PRP and PRF may improve initial bone apposition and primary healing of dental implants in patients with bisphosphonate treatment.
Collapse
|
18
|
Impact of incubation method on the release of growth factors in non-Ca 2+-activated PRP, Ca 2+-activated PRP, PRF and A-PRF. J Craniomaxillofac Surg 2018; 47:365-372. [PMID: 30578012 DOI: 10.1016/j.jcms.2018.10.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 10/17/2018] [Accepted: 10/21/2018] [Indexed: 12/29/2022] Open
Abstract
The aim of this study was to investigate the influence of different incubation methods on the growth factor content of lysates of platelet-rich fibrin (PRF), advanced-platelet-rich fibrin (A-PRF) and platelet-rich plasma (PRP) products. A comparison of related studies suggests that the method of sample preparation has a significant influence on growth factor content. There are few reports on the comparison of non-Ca2+-activated PRP, Ca2+-activated PRP, A-PRF, and PRF, along with a lack of information on the release of PDGF-BB, TGF-β1, and VEGF among the different incubation methods. The lysate preparation was made of non-Ca2+-activated PRP, Ca2+-activated PRP, PRF, and A-PRF, using a room-temperature, 37 °C, or freeze-thaw-freeze incubation method. Afterwards the VEGF, PDGF-BB, and TGF-β1 content was investigated by running ELISA tests. Growth factor levels were significantly increased in the non-Ca2+-activated PRP with freeze-thaw-freeze incubation, and in the PRF preparation there was a significant disadvantage to using room temperature incubation for releasing growth factors. In conclusion, the freeze-thaw-freeze method is sufficient for releasing growth factors, and calcium activation is not necessary. Finally, the study demonstrates the possibility of preparing PRP products from platelet concentrates, so that preoperative blood sampling might not be required.
Collapse
|
19
|
Parvovirus B19: What Is the Relevance in Transfusion Medicine? Front Med (Lausanne) 2018; 5:4. [PMID: 29450198 PMCID: PMC5799219 DOI: 10.3389/fmed.2018.00004] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Accepted: 01/09/2018] [Indexed: 01/17/2023] Open
Abstract
Parvovirus B19 (B19V) has been discovered in 1975. The association with a disease was unclear in the first time after the discovery of B19V, but meanwhile, the usually droplet transmitted B19V is known as the infectious agent of the “fifth disease,” a rather harmless children’s illness. But B19V infects erythrocyte progenitor cells and thus, acute B19V infection in patients with a high erythrocyte turnover may lead to a life-threatening aplastic crisis, and acutely infected pregnant women can transmit B19V to their unborn child, resulting in a hydrops fetalis and fetal death. However, in many adults, B19V infection goes unnoticed and thus many blood donors donate blood despite the infection. The B19V infection does not impair the blood cell counts in healthy blood donors, but after the acute infection with extremely high DNA concentrations exceeding 1010 IU B19V DNA/ml plasma is resolved, B19V DNA persists in the plasma of blood donors at low levels for several years. That way, many consecutive donations that contain B19V DNA can be taken from a single donor, but the majority of blood products from donors with detectable B19V DNA seem not to be infectious for the recipients from several reasons: first, many recipients had undergone a B19V infection in the past and have formed protective antibodies. Second, B19V DNA concentration in the blood product is often too low to infect the recipient. Third, after the acute infection, the presence of B19V DNA in the donor is accompanied by presumably neutralizing antibodies which are protective also for the recipient of his blood products. Thus, transfusion-transmitted (TT-) B19V infections are very rarely reported. Moreover, in most blood donors, B19V DNA concentration is below 1,000 IU/ml plasma, and no TT-B19V infections have been found by such low-viremic donations. Cutoff for an assay for B19V DNA blood donor screening should, therefore, be approximately 1,000 IU/ml plasma, if a general screening of blood donors for single donation blood components is considered at all: for the overwhelming majority of transfusion recipients, B19V infection is not relevant as well as for the blood donors. B19V DNA screening of vulnerable patients after transfusion seems to be a more reasonable approach than general blood donor screening.
Collapse
|
20
|
Lack of evidence for the transmission of hepatitis E virus by coagulation factor concentrates based on seroprevalence data. Transfus Med 2017; 28:427-432. [DOI: 10.1111/tme.12498] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 12/01/2017] [Accepted: 12/04/2017] [Indexed: 01/18/2023]
|
21
|
Cytomegalovirus Serostatus as Predictor for Adverse Events After Cardiac Surgery: A Prospective Observational Study. J Cardiothorac Vasc Anesth 2017; 31:2042-2048. [DOI: 10.1053/j.jvca.2016.10.024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Indexed: 11/11/2022]
|
22
|
Health-related quality of life in children, adolescents and adults with hereditary and acquired bleeding disorders. Blood Cells Mol Dis 2017; 67:96-101. [DOI: 10.1016/j.bcmd.2016.11.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 11/11/2016] [Indexed: 11/16/2022]
|
23
|
Infectivity of blood products containing cytomegalovirus DNA: results of a lookback study in nonimmunocompromised patients. Transfusion 2017; 57:1691-1698. [DOI: 10.1111/trf.14105] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 02/08/2017] [Accepted: 02/16/2017] [Indexed: 12/16/2022]
|
24
|
Assignment of C1q-binding HLA antibodies as unacceptable HLA antigens avoids positive CDC-crossmatches prior to transplantation of deceased donor organs. Transpl Immunol 2017; 41:17-21. [DOI: 10.1016/j.trim.2017.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 12/30/2016] [Accepted: 01/06/2017] [Indexed: 10/20/2022]
|
25
|
Impact of gender on safety and efficacy of Rivaroxaban in adolescents & young adults with venous thromboembolism. Thromb Res 2016; 148:145-151. [DOI: 10.1016/j.thromres.2016.09.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Revised: 07/28/2016] [Accepted: 09/11/2016] [Indexed: 12/23/2022]
|
26
|
Comparison of Two Test Strategies for Clarification of Reactive Results for Anti-HBc in Blood Donors. Transfus Med Hemother 2015; 43:37-43. [PMID: 27022321 DOI: 10.1159/000441676] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2015] [Accepted: 07/13/2015] [Indexed: 12/20/2022] Open
Abstract
OBJECTIVE Testing for antibodies against hepatitis B core antigen (anti-HBc) was introduced to detect blood donors suffering from occult hepatitis B infection. Confirmation of specification of reactive results in the anti-HBc screening assay is still a challenge for blood donation services. METHODS Two different test strategies for confirmation of specification of reactive anti-HBc tests, one performed in our institute and one suggested by the German authority (Paul-Ehrlich-Institut (PEI)), were compared. The first strategy is based on one supplemental anti-HBc test, the other requires two supplemental anti-HBc tests. RESULTS 389 samples from 242 donors were considered. Both test strategies yielded concordant results in 117 reactive samples termed 'true-positive' or 'specificity confirmed', in 156 reactive samples termed 'false-positive' or 'specificity not confirmed', and in 99 negative samples. In 17 samples obtained from 11 donors, both test strategies gave discrepant results ('false-positive' but 'specificity confirmed'). In 10 of 11 donors, a real HBV infection was very unlikely, one remained unclear. 30 donors considered 'false-positive' became negative in all anti-HBc tests after follow-up testing and thus eligible for donor re-entry. CONCLUSIONS The test strategy suggested by the PEI yielded no additional information but induced an overestimation of HBV infections and unnecessary look-back procedures. Many anti-HBc-reactive donors can be regained after follow-up testing.
Collapse
|
27
|
Look-back study on recipients of Parvovirus B19 (B19V) DNA-positive blood components. Vox Sang 2015; 109:305-11. [PMID: 26053938 DOI: 10.1111/vox.12295] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Revised: 04/01/2015] [Accepted: 04/08/2015] [Indexed: 12/20/2022]
Abstract
BACKGROUND AND OBJECTIVES To assess the relevance of Parvovirus B19 (B19V) DNA at low to intermediate concentrations in blood donors for the recipients of their blood components. MATERIAL AND METHODS We studied recipients of B19V DNA-positive blood components [red blood cell concentrates (RBCs), pooled platelet concentrates and fresh frozen plasma]. This included archived pretransfusion samples as well as follow-up samples investigated by ELISA or NAT and genome sequence analysis. RESULTS In 132 out of 424 recipients, we could detect no anti-B19V IgG before transfusion. In 67 out of 132 sero-negative recipients, a follow-up sample was available. Sixty-five of these received blood components from donors with <10(4) IU B19V DNA/ml plasma and had no evidence of transfusion-transmitted (TT)-B19V infection. Homology in genome sequences in donor and recipient provided evidence for a TT-B19V infection in two recipients. Both patients received RBC containing 3.4 × 10(6) and 1.8 × 10(4) IU B19V DNA/ml plasma, respectively. The anti-B19V IgG titres in the donors were 2 and 76 IU/ml plasma, respectively. The antibodies in the second donor were directed against capsid proteins and are thus considered as potential neutralizing antibodies. CONCLUSIONS TT-B19V infections through blood components with low (<10(4) IU/ml plasma) B19V DNA concentrations did not occur in our study. One of the TT-B19V infections occurred from RBC with intermediate B19V DNA concentration despite the presence of potential neutralizing antibodies in the donor, but its clinical significance was low.
Collapse
|
28
|
Prevalence of pemphigus and pemphigoid autoantibodies in the general population. Orphanet J Rare Dis 2015; 10:63. [PMID: 25971981 PMCID: PMC4436865 DOI: 10.1186/s13023-015-0278-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Accepted: 04/29/2015] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND Mucocutaneous blistering is characteristic of autoimmune bullous dermatoses (AIBD). Blisters are caused by autoantibodies directed against structural components of the skin. Hence, detection of specific autoantibodies has become a hallmark for AIBD diagnosis. Studies on prevalence of AIBD autoantibodies in healthy individuals yielded contradictory results. METHODS To clarify this, samples from 7063 blood donors were tested for presence of anti-BP180-NC16A, anti-BP230 and anti-Dsg1/3 IgG by indirect immunofluorescence (IF) microscopy using a biochip. RESULTS Cumulative prevalence of these autoantibodies was 0.9 % (CI: 0.7-1.1 %), with anti-BP180-NC16A IgG being most prevalent. Validation of IF findings using ELISA confirmed presence of autoantibodies in 7/15 (anti-Dsg1), 6/7 (anti-Dsg3), 35/37 (anti-BP180-NC16A) and 2/3 (anti-BP230) cases. Moreover, in 16 samples, anti-BP180-NC16A autoantibody concentrations exceeded the cut-off for the diagnosis of bullous pemphigoid. Interestingly, these anti-BP180-NC16A autoantibodies from healthy individuals formed immune complexes with recombinant antigen and dose-dependently activated neutrophils in vitro. However, fine-epitope mapping within NC16A showed a different binding pattern of anti-BP180-NC16A autoantibodies from healthy individuals compared to bullous pemphigoid patients, while IgG subclasses were identical. CONCLUSIONS Collectively, we here report a low prevalence of AIBD autoantibodies in a large cohort of healthy individuals. Furthermore, functional analysis shows differences between autoantibodies from healthy donors and AIBD patients.
Collapse
|
29
|
Co-occurrence of autoantibodies in healthy blood donors. Exp Dermatol 2014; 23:519-21. [DOI: 10.1111/exd.12445] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/09/2014] [Indexed: 11/26/2022]
|
30
|
Persistence of Parvovirus B19 (B19V) DNA and humoral immune response in B19V-infected blood donors. Vox Sang 2014; 107:226-32. [PMID: 24916600 DOI: 10.1111/vox.12162] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2014] [Revised: 04/30/2014] [Accepted: 05/07/2014] [Indexed: 11/30/2022]
Abstract
BACKGROUND AND OBJECTIVES Parvovirus B19 (B19V) DNA seems to persist in the plasma of B19V-infected blood donors. The relevance of this for recipients of single-donor blood components is yet unclear. MATERIAL AND METHODS We studied serial archive and follow-up samples from 75 B19V-infected blood donors to obtain more data about the duration and degree of viraemia and the presence of IgG and IgM anti-B19V. IgG antibodies were further characterized by Western blot analysis in 29 donors. RESULTS In 411 B19V DNA-positive samples collected, we found high concentrations (>10(6) IU B19V DNA/ml plasma) in five. B19V DNA persisted for a mean of 21·5 months (range: 2·3-52·4; 95% confidence interval, 19·1-23·9 months) in all donors. Only 15 such samples had either no or low-titre IgG anti-B19V. IgG antibodies were predominantly directed against epitopes on the minor capsid protein VP1, thus probably of neutralizing type with high avidity. IgM anti-B19V was detectable in 9/13 samples with high DNA concentrations. CONCLUSIONS The vast majority of single-donor blood components with detectable B19V DNA are probably not infectious for their recipients because DNA is at only low levels and the donors also have potentially neutralizing antibodies with high avidity. Anti-B19V IgM testing does not identify every donation with high B19V DNA concentrations, but, in addition to B19V NAT testing, donors with persistent IgG anti-B19V might be considered 'B19V-safe' for single-donor blood components.
Collapse
|
31
|
Parvovirus b19 infections and blood counts in blood donors. ACTA ACUST UNITED AC 2013; 41:52-9. [PMID: 24659948 DOI: 10.1159/000357650] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 11/22/2013] [Indexed: 11/19/2022]
Abstract
OBJECTIVES Parvovirus B19 (B19V) is a transfusion-transmissible virus. To obtain data about the prevalence, incidence, the course of B19V infection in blood donors and whether B19V might impair their blood counts, samples from blood donors with B19V infection were investigated. METHODS Blood donations were screened for B19V DNA using the Cobas TaqScreen DPX Test® in mini-pools. B19V DNA concentration, anti-B19V IgG antibody titer and blood counts were determined in positive donors. RESULTS 157/23,889 (0.66%) donors provided 347 B19V DNA-positive samples. Prevalence of B19V infection was 0.45%, incidence 0.20%. B19V DNA concentrations were predominantly low; only in 8 samples were viral loads of ≥10(5) IU B19V DNA/ml plasma detectable. Besides a slight decrease in hemoglobin, hematocrit, mean corpuscular volume, mean cellular hemoglobin and mean hemoglobin concentration, no major differences in blood counts occurred in B19V DNA-positive samples. In samples with a low B19V DNA concentration, anti-B19V IgG titers were rather high. 98 donors provided at least 1 B19V DNA-positive follow-up sample, indicating a prolonged viremia. CONCLUSIONS B19V infection induced no major impairment in the blood counts. In donors with low-level viremia, infectivity through their donations is probably reduced by high antibody titers. Low-level viremia is prolonged, probably exceeding 1 year in many cases.
Collapse
|
32
|
Autochthonous hepatitis e virus infections: a new transfusion-associated risk? ACTA ACUST UNITED AC 2013; 41:29-39. [PMID: 24659945 DOI: 10.1159/000357098] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 07/05/2013] [Indexed: 12/16/2022]
Abstract
Hepatitis E virus (HEV) has been recognized since 2004 as a transfusion-transmissible infectious agent, and recent epidemiological data suggest that it may pose a safety threat to the blood supply. It has recently become obvious that hepatitis E is endemic in industrialized countries, and that more infections are autochthonous than travel-associated. Epidemiological and phylogenetic analysis suggests that HEV infection has to be considered as a zoonosis and that viral transmission from animals (pigs, wild animals) occurs through food or direct contact. The seroprevalence and incidence of HEV in the general population and blood donors in European countries indicate an underestimated risk for transfusion transmissions. Recently reported cases of transfusion transmission of HEV infection, and detection of viremic, asymptomatic blood donors in nucleic acid amplification technique screening programs give an indication of the importance of this virus. Diagnostic assays for detection of anti-HEV antibodies, HEV antigens and RNA are discussed. Recent studies support the idea that active immunization can prevent hepatitis E, highlighting the need for vaccination programs. Here we review current knowledge of HEV and its epidemiology, blood transmission and prevention of this disease with emphasis on blood supply.
Collapse
|
33
|
AB0734 Prevalence and co-occurrence of autoantibodies in blood donors. Ann Rheum Dis 2013. [DOI: 10.1136/annrheumdis-2012-eular.734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
34
|
The impact of donor cytomegalovirus DNA on transfusion strategies for at-risk patients. Transfusion 2013; 53:2183-9. [PMID: 23581526 DOI: 10.1111/trf.12199] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2012] [Revised: 02/11/2013] [Accepted: 02/28/2013] [Indexed: 11/29/2022]
Abstract
BACKGROUND Cytomegalovirus (CMV) DNA is frequently detected in plasma of newly seropositive donors. Selection of leukoreduced blood products from donors with remote CMV infection could avoid transfusion-transmitted CMV infections (TT-CMV) due to primarily infected donors. However, there are no data about the prevalence of reactivations in long-term seropositive donors compared to the incidence of window period donations in seronegative donors. Therefore, the optimal transfusion strategy for at-risk patients is unclear. STUDY DESIGN AND METHODS Whole blood samples from 22,904 donations were tested for CMV DNA, and CMV DNA-positive donations were categorized as donations from 1) seronegative donors, 2) newly seropositive donors, and 3) long-term seropositive donors. RESULTS Twenty-one donors were reproducibly CMV DNA-positive (0.09%). Frequency of detection and concentration of CMV DNA in whole blood were comparable for seronegative and long-term seropositive donors. Nonreproducibly positive results for CMV DNA in whole blood were more frequent in long-term seropositive donors (0.16% vs. 0.01%, p<0.01). Only low concentrations of CMV DNA in plasma were detectable in two seronegative donors and one long-term seropositive donor. Highest concentrations of CMV DNA in both whole blood and plasma, however, were found in newly seropositive donors. CONCLUSION Prevalences of window period donations among seronegative donors and reactivations among long-term seropositive donors, as well as the CMV DNA concentration in whole blood and plasma samples from these donors, are comparable. Therefore, blood products from both groups could be used for patients at risk for TT-CMV, while those of newly seropositive donors seem to bear an increased risk.
Collapse
|
35
|
Comparison of the two fully automated anti-HCMV IgG assays: Abbott Architect CMV IgG assay and Biotest anti-HCMV recombinant IgG ELISA. Transfus Med 2013; 23:187-94. [DOI: 10.1111/tme.12036] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2012] [Revised: 03/08/2013] [Accepted: 03/12/2013] [Indexed: 11/27/2022]
|
36
|
Seroprevalence and incidence of hepatitis E virus infection in German blood donors. Transfusion 2013; 54:49-56. [PMID: 23441647 DOI: 10.1111/trf.12121] [Citation(s) in RCA: 91] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2012] [Revised: 11/29/2012] [Accepted: 12/15/2012] [Indexed: 01/10/2023]
Abstract
BACKGROUND Hepatitis E virus (HEV) is transmissible by transfusion. More data are needed about seroprevalence, incidence, and viremia in blood donors for the assessment of risk of transfusion-transmitted (TT)-HEV infections. STUDY DESIGN AND METHODS Samples from 1019 whole blood donors were tested for anti-HEV immunoglobulin (Ig)G by enzyme-linked immunosorbent assay and Western blot. The incidence of HEV and presence of HEV RNA in donors who seroconverted were determined by testing archive samples and recipients of viremic donations were traced. Anti-HEV IgM and alanine transaminase (ALT) testing were also performed to assess the value of such measures in the prevention of TT-HEV infections. RESULTS A total of 69 of 1019 donors tested positive for anti-HEV IgG (6.8% seroprevalence), and seroconversion for anti-HEV IgG occurred in seven of 69 donors within 2 years (incidence, 0.35%/year). Three of seven (42.8%) seroconverting donors provided an archive sample in which HEV RNA was detectable. One recipient of these donations was traceable; anti-HEV IgG, IgM, and HEV RNA testing were negative 41 days after transfusion. Neither ALT levels nor anti-HEV IgM detection correlated with the presence of HEV RNA. CONCLUSIONS The seroprevalence of HEV was 6.8%, and the annual incidence 0.35%. HEV RNA was detectable in several seroconverting donors, without evidence for HEV transmission in the only traceable recipient. Since neither ALT nor anti-HEV IgM testing correlate with the presence of HEV RNA, HEV nucleic acid testing currently provides the only method for the prevention of TT-HEV infection. However, before implementation, more data about clinical relevance of TT-HEV infections and infectious dose of HEV are required.
Collapse
|
37
|
Evaluation of algorithms for the diagnostic assessment and the reentry of blood donors who tested reactive for antibodies against hepatitis B core antigen. Transfusion 2011; 51:1477-85. [DOI: 10.1111/j.1537-2995.2010.03031.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
38
|
Detection of herpes simplex virus DNA in plasma of patients with primary but not with recurrent infection: implications for transfusion medicine? Transfus Med 2010; 20:38-47. [DOI: 10.1111/j.1365-3148.2009.00951.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
39
|
Abstract
BACKGROUND AND OBJECTIVES As cytomegalovirus (CMV) DNA is frequently detectable in the plasma of recently infected sero-positive blood donors, information concerning primary CMV infection is important for the identification of possibly infectious donors. MATERIALS AND METHODS Monitoring of 17 982 donors for CMV antibodies and DNA in plasma identified 14 subjects with ongoing primary CMV infection. Thirteen donors were interrogated for possible sources of infection and CMV-related symptoms, and monitored for CMV antigens, CMV DNA in plasma, leucocytes and urine, course of IgG and IgM antibodies as well as markers of systemic infection and parameters of organ function. RESULTS CMV antigens and DNA were detectable in peripheral blood for up to 54 and 269 days respectively. Clearance of CMV DNA from blood correlated with clearance of IgM antibodies, development of IgG antibodies against the membrane glycoprotein gB and development of high avidity IgG antibodies. Eighty-five percent of subjects with primary CMV infection, but even 69% of matched controls reported possibly CMV-related symptoms. Sixty-two and 23%, respectively, had contact with possible sources of infection. One donor developed a febrile illness accompanied by increased levels of CMV DNA in peripheral blood 2 to 3 weeks after seroconversion. In other donors, neither markers of systemic infection nor parameters of organ function correlated with the course of CMV DNA and antigens. CONCLUSION Potentially infectious donors can be identified by measuring CMV DNA, IgM antibodies or avidity of IgG antibodies. Alternatively, blood products donated during the first year after seroconversion should not be used for immunocompromised patients.
Collapse
|
40
|
Heparin-induced thrombocytopenia: a prospective study on the incidence, platelet-activating capacity and clinical significance of antiplatelet factor 4/heparin antibodies of the IgG, IgM, and IgA classes. J Thromb Haemost 2007; 5:1666-73. [PMID: 17488345 DOI: 10.1111/j.1538-7836.2007.02617.x] [Citation(s) in RCA: 168] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Platelet-activating antiplatelet factor 4/heparin (anti-PF4/heparin) antibodies are the major cause of heparin-induced thrombocytopenia (HIT). However, the relative utility of functional (platelet activation) vs. antigen [enzyme-immunoassay (EIA)] assays, and the significance of assay discrepancies remain unresolved. METHODS Consecutive patient sera (n = 1650) referred for diagnostic HIT testing were screened prospectively by both the heparin-induced platelet activation (HIPA) test and anti-PF4/heparin EIA - including individual classes (IgG, IgA, IgM) - with clinical correlations studied. Platelet microparticle and annexin-V-binding properties of the sera were also investigated. RESULTS Only 205 (12.4%) sera tested positive in either the HIPA and/or EIA: 95 (46.3%) were positive in both, 109 (53.1%) were only EIA-positive, and, notably, only one serum was HIPA-positive/EIA-negative. Of 185 EIA-positive sera, only 17.6% had detectable IgM and/or IgA without detectable IgG. Among sera positive for EIA IgG, optical density values were higher when the sera were HIPA-positive (1.117 vs. 0.768; P < 0.0001), with widely overlapping values. Two HIPA-positive but EIA-IgG-negative sera became HIPA-negative following IgG depletion, suggesting platelet-activating antibodies against non-PF4-dependent antigens. Clinical correlations showed that HIPA-negative/EIA-positive patients did not develop thrombosis and had reasons other than HIT to explain thrombocytopenia. IgM/A antibodies did not increase microparticle penetration, but increased annexin-V binding. CONCLUSIONS The anti-PF4/heparin EIA has high ( approximately 99%) sensitivity for HIT. However, only about half of EIA-positive patients are likely to have HIT. Anti-PF4/heparin antibodies of IgM/A class and non-PF4-dependent antigens have only a minor role in HIT.
Collapse
|
41
|
Incidence and clinical significance of anti-PF4/heparin antibodies of the IgG, IgM, and IgA class in 755 consecutive patient samples referred for diagnostic testing for heparin-induced thrombocytopenia. Eur J Haematol 2006; 76:420-6. [PMID: 16466367 DOI: 10.1111/j.1600-0609.2005.00621.x] [Citation(s) in RCA: 131] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Heparin-induced thrombocytopenia (HIT) is usually caused by anti-platelet factor 4 (PF4)/heparin antibodies, leading to intravascular platelet activation. These antibodies can be detected by PF4/polyanion antigen assays or platelet activation assays. While antigen assays are very sensitive and recognize immunoglobulin (Ig)G, IgA, and IgM antibodies, the role of IgM and IgA HIT-antibodies is debated. Platelet activation assays recognize IgG and are more specific for clinical HIT. METHODS We analyzed sera from 755 consecutive patients referred for diagnostic testing for HIT using a PF4/heparin enzyme-linked immunosorbent assay (ELISA) for IgG, IgA, and IgM and by the heparin-induced platelet activation (HIPA) test. Clinical information was provided by the treating physicians. RESULTS A total of 108 of 755 (14.3%) patients tested positive, 105 (13.9%) in the PF4/heparin IgG/A/M ELISA [28 (26.7%) only for IgM/A]; 53 (7.0%) sera were positive in the HIPA, of those 50 tested also positive in the ELISA. In 77 patients sufficient clinical information was provided. Available clinical information for 17 of the 28 patients who had only IgM and/or IgA detected showed plausible alternative (non-HIT) explanations in four of seven who had thromboembolic complications and in nine of 10 who had isolated HIT. CONCLUSION Detection of IgG, IgM and IgA class antibodies by PF4/heparin ELISA yields a positive test result about twice as often as does a platelet activation assay, with only a minority of the additional patients detected likely having HIT. Thus, there is a potential for considerable over-diagnosis of HIT by laboratories that utilize only an ELISA for diagnostic testing.
Collapse
|
42
|
Evaluation of pretest clinical score (4 T's) for the diagnosis of heparin-induced thrombocytopenia in two clinical settings. J Thromb Haemost 2006; 4:759-65. [PMID: 16634744 DOI: 10.1111/j.1538-7836.2006.01787.x] [Citation(s) in RCA: 645] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Heparin-induced thrombocytopenia (HIT) is a prothrombotic adverse drug reaction caused by heparin. As thrombocytopenia is common in hospitalized patients receiving heparin, it would be useful to have a clinical scoring system that could differentiate patients with HIT from those with other reasons for thrombocytopenia. AIM To compare prospectively the diagnostic utility of a clinical score for HIT in two different clinical settings. METHODS The pretest clinical scoring system, the '4 T's', was used to classify 100 consecutive patients referred for possible HIT in one hospital (Hamilton General Hospital, HGH) into high, intermediate, and low probability groups. This system was also used to classify likewise 236 patients by clinicians in Germany referring blood for diagnostic testing for HIT in Greifswald (GW). The clinical scores were correlated with the results of laboratory testing for HIT antibodies using the serologic criteria for HIT with high diagnostic specificity. RESULTS In both centers, patients with low scores were unlikely to test positive for HIT antibodies [HGH: 1/64 (1.6%), GW: 0/55 (0%)]. Patients with intermediate [HGH: 8/28 (28.6%), GW: 11/139 (7.9%)] or high scores [HGH: 8/8 (100%), GW: 9/42 (21.4%)] were more likely to test positive for clinically significant HIT antibodies. The positive predictive value of an intermediate or high clinical score for clinically significant HIT antibodies was higher at one center (HGH). CONCLUSIONS A low pretest clinical score for HIT seems to be suitable for ruling out HIT in most situations (high-negative predictive value). The implications of an intermediate or high score vary in different clinical settings.
Collapse
|