1
|
Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires. Eur J Orthod 2005; 27:72-81. [PMID: 15743866 DOI: 10.1093/ejo/cjh076] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Orthodontic wires are frequently packaged in individual sealed bags in order to avoid cross-contamination. The instructions on the wrapper generally advise autoclave sterilization of the package and its contents if additional protection is desired. However, sterilization can modify the surface parameters and the mechanical properties of many types of material. The aim of this research was to determine the influence of one of the most widely used sterilization processes, autoclaving (18 minutes at 134 degrees C, as recommended by the French Ministry of Health), on the surface parameters and mechanical properties of six wires currently used in orthodontics (one stainless steel alloy: Tru-Chrome RMO; two nickel-titanium shape memory alloys: Neo Sentalloy and Neo Sentalloy with Ionguard GAC; and three titanium-molybdenum alloys: TMA(R) and Low Friction TMA Ormco and Resolve GAC). The alloys were analysed on receipt and after sterilization, using surface structure observation techniques, including optical, scanning electron and atomic force microscopy and profilometry. The mechanical properties were assessed by three-point bending tests. The results showed that autoclave sterilization had no adverse effects on the surface parameters or on the selected mechanical properties. This supports the possibility for practitioners to systematically sterilize wires before placing them in the oral environment.
Collapse
|
2
|
Mechanical properties of two orthodontic adhesive materials polymerized with halogen and plasma curing. Biomed Mater Eng 2005; 15:269-77. [PMID: 16010035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
OBJECTIVES The aim of this study is to compare the efficiency of two polymerization techniques (halogen curing--Astralis 7 and plasma curing--Flipo), with two orthodontic adhesive materials (Enlight, a composite resin, and Fuji Ortho LC, a glass ionomer cement). METHODS The efficiency of the polymerization techniques was shown by two mechanical tests. The hardness test was carried out on the exposed and non-exposed surfaces using 10 x 4 x 3-mm samples, polymerized either by halogen curing (40 seconds) or by plasma curing (5 seconds). The three-point bending tests were carried out on 2 x 2 x 25-mm samples polymerized as above. The samples were kept 1 hr at room temperature, then for 24 hrs in distilled water at 37 degrees C. RESULTS Whatever the polymerization technique used, the results are similar for hardness and flexion, with the exception of the hardness tests carried out after polymerization with the Flipo light on the surface not directly exposed. CONCLUSION In orthodontic practice, both polymerization techniques can be used. But a multi-bracket session can be long, and the reduction of time spent in the chair obtained by using plasma lamps seems to make this technique preferable.
Collapse
|
3
|
Nitinol surface roughness modulates in vitro cell response: a comparison between fibroblasts and osteoblasts. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2005. [DOI: 10.1016/j.msec.2004.06.001] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
4
|
Effect of type of polymerization on different properties of dental composites. Biomed Mater Eng 2005; 15:483-93. [PMID: 16308463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The aim of this study is to assess the influence of plasma lamps on the properties of the composites compared to the influence of conventional polymerization. Vickers hardness tests, three-point bending tests, and measurement of the shrinkage marginal gap by scanning electron microscopy were carried out on three resin composites (Tetric Ceram, Z-100 and Inten-S) irradiated with to lamps (Flipo) plasma and Astralis 7 halogen lamps). With a 3-second exposure, the results of Vickers hardness and resistance to flexion (excepting values for Z-100) were lower for the composites cured by the Flipo plasma lamp, than after 40-second curing by the conventional halogen lamp (Astralis 7), notably at a depth of 3 mm. With a 5-second exposure the results of Vickers hardness and resistance to flexion obtained using the plasma lamp approached those obtained by using the halogen lamp. Whatever the polymerization protocol used, the measurements of the gap between the tooth and the filling are very similar except for Z-100/Astralis 7, for which shrinkage results are more important. For any one resin composite and lamp used, the shrinkage values obtained at a depth of 4 mm are twice higher than those obtained at the surface. In conclusion, for a 3-second exposure the level of polymerization obtained by plasma curing is lower than the one obtained by halogen curing, particularly in depth. On the other hand, 5-second plasma curing results recommends the use of this kind of lamp.
Collapse
|
5
|
Trabecular alveolar bone microarchitecture in the human mandible using high resolution magnetic resonance imaging. Dentomaxillofac Radiol 2004; 33:177-82. [PMID: 15371318 DOI: 10.1259/dmfr/42933309] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES Cancellous bone microarchitecture in the mandible can influence the success of dental implant osseointegration. The aims of this study were to explore the feasibility of two-dimensional (2D) high resolution magnetic resonance imaging (MRI) for the evaluation of trabecular bone architecture and to compare architecture parameters derived from MR images between different areas in the mandible, and between sex and dental status. METHODS 45 mandibular bone specimens (8 mm thickness) were cut from 15 fresh cadavers. MR images were obtained at 2 T using a multislice 2D spin-echo sequence. After MR image binarization, histomorphometry parameters, i.e. bone area fraction (BAF), specific perimeter (La), trabecular bone width (Tb.Wi), trabecular bone separation (Tb.Sp) and trabecular network anisotropy (R), were computed from the mean intercept length. The angle between trabeculae and tooth axis and the Euler-Poincaré characteristics (EPCs) were also computed. RESULTS BAF, Tb.Wi and R were significantly higher in male specimens compared with female specimens, whereas Tb.Sp was significantly lower. The apparent Tb.Wi was found to be significantly higher in dentate specimens compared with edentulous ones. The highest anisotropy, corresponding to the smallest R value, was seen in the incisal specimens. The preferential orientation of the trabeculae was close to perpendicular to the tooth axis, especially in the molar specimens. CONCLUSION BAF, La, Tb.Wi, Tb.Sp and R, the most variable parameters, may potentially have a relationship with the biomechanical competence of trabecular bone and play a role both in primary stabilization of dental implant and the time needed before loading.
Collapse
|
6
|
Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy. Biomed Mater Eng 2004; 14:323-31. [PMID: 15299244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
OBJECTIVES The aim of this study was to compare the electrochemical behaviour of two materials used in oral implantology. METHODS The resistance to corrosion of Ti grade 2 and the alloy Ti-6Al-4V was studied in an artificial saliva solution. It has been observed that the passivation of titanium by an oxidised layer can be shown both by cyclic voltametry and by electrochemical impedance spectroscopy. Moreover, this latter technique, rarely used in odontology, opens up interesting perspectives, enabling a more quantitative approach to the resistance of the passive layer to be adopted. RESULTS Also, the impedance data recorded for Ti grade 2 and the alloy Ti-6Al-4V, in the artificial saliva solution were shown that Ti grade 2 has a higher resistance to corrosion and a thicker oxide layer than the alloy Ti-6Al-4V. SIGNIFICANCE The fact that the electrochemical properties of Ti-6Al-4V are lower than that titanium's ones indicate than a release of ions aluminum and or vanadium ions in the body can occur. This is why we recommend to the dental practitioners to preferably use titanium in implantology.
Collapse
|
7
|
Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2003. [DOI: 10.1016/s0928-4931(03)00033-x] [Citation(s) in RCA: 339] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
8
|
Effect of surface topography and chemistry on adhesion, orientation and growth of fibroblasts on nickel–titanium substrates. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2002. [DOI: 10.1016/s0928-4931(02)00097-8] [Citation(s) in RCA: 114] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Influence of gamma-irradiation sterilization on the structural defects of sapphire single crystals (alpha-Al(2)O(3)). Biomed Mater Eng 2002; 11:265-73. [PMID: 11564909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
The influence of sterilization by gamma rays on the structure and the electrical behaviour of sapphire single crystal (alpha-Al(2)O(3)) was studied successively by thermoluminescence, by cathodoluminescence and by observation of the scanning electron microscope mirror effect. The mirror method allowed us to measure the capacity of an insulating material to trap electrons. The structural analysis of the alpha-Al(2)O(3) showed that there were oxygen vacancies, as well as chromium and titanium impurities. It was possible to demonstrate that these defects, especially the oxygen vacancies, are in a different state after a 30 kilogray irradiation. The valency state changes of these defects and the presence of trapped charges are accompanied by a deformation of the crystalline lattice which results in a modification of its electrical properties. At room temperature, the irradiated alpha-Al(2)O(3), unlike non irradiated alpha-Al(2)O(3), is capable of trapping electrons. It can be concluded that gamma-ray sterilization modifies the cohesive energy of alpha-Al(2)O(3), which could lead to mechanical changes (surface charge, friction, wear, fracture strength, em leader) in this material.
Collapse
|
10
|
Abstract
The aim of this study was to compare the resistance of the corrosion of dental alloys in a solution containing oral bacteria named Actinomyces viscosus (ATCC19246). In this paper, we explain the choice of this precise species of bacteria, then specify its culture in artificial saliva and the experimental precautions needed to avoid the pollution by other bacteria. The electrochemical behaviour of two dental alloys (Ni-Cr alloy and gold-based alloy) was investigated by electrochemical means in sterile Fusayama artificial saliva (AS), AS enriched with sterile yeast extract (YE) and YE modified by introducing bacteria (AV). Open-circuit potentials, potentiodynamic curves, polarization resistance and impedance spectroscopy are the electrochemical procedures selected for this work. It has thus been shown that the open-circuit potential of the non-precious alloy is always lower than that of the gold precious alloy, and the colonization of metal surface by bacteria caused a drop in open circuit potential. The electrochemical impedance spectroscopy results have shown that the electrolyte resistance decreased between the AS, YE and AV milieu, in the presence of bacteria a slight decrease in polarization resistance was observed with the precious alloy and an increase with the non-precious alloy. The drop in the electrolyte resistance cannot explain the change in polarization resistance. The influence of Actinomyces viscosus might be essentially due to the consumption of oxygen at the metal/electrolyte interface of the specimen. For the non-precious alloy, the absence of oxygen (instigator of corrosion) led to an increase in polarization resistance whereas the slight decrease for the precious alloys might be justified by the organic and inorganic metabolites released by bacteria in to the electrolyte. The scanning electron micrography after electrochemical analysis, confirmed the absence of contaminants. These preliminary results demonstrate the unquestionable influence of this bacteria on the corrosion behaviour of the alloys studied, however, further studies are necessary.
Collapse
|
11
|
Abstract
The behavior of cultured rat bone cells growing on modified polyethylene terephthalate (mPET), glass, and machinable ceramic substrates containing enstatite (MgO, SiO2) and glass (CaO-P2O5-Al2O3) was studied. Cell attachment was measured directly on the substrates using an image analysis system. Electron microscopy observations and the MTT test revealed that cells are able to spread and proliferate on the material surface, keeping a healthy ultrastructure on all materials tested in the present study. After having colonized the surface of the materials, as shown by immunocytochemistry, the cells synthesize an osteoid-like matrix composed of osteocalcin, type I collagen, and fibronectin fibrils. The titration of alkaline phosphatase activity showed that the cells grown on the ceramic exhibit a greater osteogenic activity than those grown on controls (glass and mPET). This osteogenic activity results in a mineralization of the extracellular matrix in cultures on ceramic or plastic whereas only few calcium phosphate crystallite traces were revealed by Von Kossa staining on glass. Enstatite constitutes, therefore, an environment compatible with in vitro bone cell life.
Collapse
|
12
|
Abstract
This fluorescence image analysis method for the quantitative determination of cell adhesion on biomaterials allows bone cells labelled with propidium iodide to be counted automatically, directly on their support. The reliability of the estimation by fluorescence image analysis was validated by comparison with visual counting and with results obtained by an electronic particle counter. In this way it was possible to demonstrate that the adhesive properties of bone cells are dependent on the type of substrate--enstatite (MgO, SiO2, CaO-P2O5-Al2O3), Thermanox (modified polyethyleneterephthalate), or glass. In contrast, the spread of the cell cytoplasm, labelled with fluorescein isothiocyanate and measured by image analysis, does not vary significantly according to the substrate. The characterisation by SKIZ tessellation of the spatial cell arrangement shows that the bone cells have a random organisation on Thermanox and glass, whereas they form aggregates on enstatite.
Collapse
|
13
|
Measurement and evaluation of galvanic corrosion between titanium/Ti6A14V implants and dental alloys by electrochemical techniques and auger spectrometry. Biomaterials 1999; 20:933-41. [PMID: 10353647 DOI: 10.1016/s0142-9612(98)00248-8] [Citation(s) in RCA: 100] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The purpose of this study was to investigate, in different experimental conditions, the galvanic corrosion phenomena which can exist between a dental suprastructure and a dental implant. The electrochemical behavior of 7 alloy superstructures with titanium and titanium alloy (Ti6A14V) implants was investigated by electrochemical means in Fusayama-Meyer de-aerated saliva and Carter-Brugirard (AFNOR) non de-aerated saliva. Different techniques were used to obtain the value of the galvanic coupling current and potential for each couple. All showed very low corrosion rates, ranging from 10(-6) to 10(-8) A. Surface analysis confirmed these results.
Collapse
|
14
|
Abstract
In this paper, the anatomical structures of rat jaws are studied using magnetic resonance imaging (MRI) with high spatial resolution. In vivo microimages of teeth from 3- and 12-week-old (young and adult) rats have been performed. A 2 T nuclear magnetic resonance microscope was used to collect, with multiple orientations, non-invasive 2D data images using the spin-echo technique. MRI appears well suited to give images of the oral area and may represent a useful tool for diagnosis of dental diseases and more particularly of pulp pathologies.
Collapse
|
15
|
Cytokeratin expression in human oral gingival epithelial cells: in vitro regulation by titanium-based implant materials. Biomaterials 1998; 19:1109-15. [PMID: 9692810 DOI: 10.1016/s0142-9612(98)00041-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
To evaluate whether cytokeratin expression in human oral epithelial cells could be influenced by implant materials used in dental surgery, passaged human oral gingival epithelial cells were seeded on commercially pure titanium (CP-Ti) or on Ti6Al4V titanium alloy. Confluence was achieved after about 15 days on both substrates. Cells formed at that time, an organized layer of densely packed polygonal cells, and harbored a filamentous cytokeratin network typical of epithelial cells. Immunochemistry and immunoblot analysis were used to detect modifications of the amount of individual CK polypeptides (CK7, 8, 13, 18 and 19) in function of the culture substrate. Results showed that the level of CK8, CK18 and CK19 expression was not altered whatever the culture substrate used. The expression of CK13 was reduced in epithelial cells cultured on the titanium alloy, as compared with commercially pure titanium. Conversely, the level of CK7 was higher on the Ti6Al4V alloy than on commercially pure titanium. This study suggests that titanium-based implant materials could influence differently the phenotype of oral gingival epithelial cells.
Collapse
|
16
|
A metabolism study of human masseter muscle by 31P magnetic resonance spectroscopy during long periods of exercise and recovery. Eur J Oral Sci 1998; 106:552-8. [PMID: 9527354 DOI: 10.1046/j.0909-8836.1998.eos106103.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The metabolism of the human masseter muscle was investigated using phosphorus (31p) magnetic resonance spectroscopy (MRS) during long periods of exercise and recovery. Eleven subjects aged 19 to 28 yr were examined by 31p MRS during four consecutive periods of 13 min each: rest, exercise, recovery 1 and 2. For each subject, a biting force equal to 20% of maximum voluntary biting force was applied and controlled during the exercise period to produce maximum fatigue. 31p MR spectra were localized from a 24 cm3 volume of interest using an image selected in vivo spectroscopy (ISIS) sequence and a 6 cm diameter surface coil placed on the left masseter. Compared to the resting level, the phosphocreatine (PCr) content decreased by 26% during exercise, while the inorganic phosphate (Pi) concentration increased by 65%. During the two recovery periods, the Pi content remained decreased compared with the resting level by 36% and 30%, respectively. The Pi/PCr ratio was increased from 0.30+/-0.04 at rest to 0.63+/-0.13 during exercise while the adenosine triphosphate (ATP)/Pi ratio was decreased. The pH decreased from 7.02+/-0.03 to 6.93+/-0.04 during exercise and returned to control level (7.09+/-0.08) only during the second recovery period. These results suggest that the masseter muscle is characterized by high ATP turnover and, therefore, high oxidative phosphorylative activity in agreement with its constitution of predominantly fatigue resistant type I fibers.
Collapse
|
17
|
Abstract
This study compared the efficacy of three different polishing methods on a resin composite, a glass ionomer cement (GIC) and a compomer. Thirty samples of each material were prepared. Ten of them were randomly assigned to one of the three polishing methods. The surface roughness (Ra) of the samples were measured before and after the polishing procedure with a profilometer. There was no statistical difference between the composite and the compomer prior to polishing but statistical difference was found between the GIC and the two other materials. After polishing, the smoothest surfaces were obtained using Sof-Lex discs for the three materials, and the roughest surface, with tungsten carbide burs for the composite and the compomer, and with Enhance kit for the GIC. The composite gave the smoothest surface with the three methods.
Collapse
|
18
|
In vitro magnetic resonance imaging of rodent teeth. ORAL SURGERY, ORAL MEDICINE, ORAL PATHOLOGY, ORAL RADIOLOGY, AND ENDODONTICS 1997; 84:582-5. [PMID: 9394393 DOI: 10.1016/s1079-2104(97)90277-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE The anatomic structure of rat teeth was studied and observed using magnetic resonance imaging with high spatial resolution. STUDY DESIGN The right part of the low mandible of two rats of 3 and 12 weeks old were analyzed. Images with different orientations were performed in a 2 Tesla magnetic field using the spin-echo imaging technique. RESULTS Highly spatially resolved images revealed details of teeth, and anatomic differences between a young and an adult rat were demonstrated. CONCLUSION Magnetic resonance imaging is well suited to image the buccal area and may be a useful tool for the diagnosis of dental diseases.
Collapse
|
19
|
[Anatomical study with MRI of a small muscle: the masseter]. JOURNAL DE RADIOLOGIE 1997; 78:359-66. [PMID: 9239338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Magnetic resonance imaging (MRI) provides functional information in an anatomic presentation allowing to distinguish soft tissues with high sensitivity. The goal of this study was to investigate the normal anatomy of the major masticatory muscle, the masseter, both at rest or during contraction by using three dimensional (3D) MRI. Eighteen subjects aged from 19 to 28 years, all in good health, were studied. Several experiments were first realized on phantoms to test the 3D-MRI technique. After reconstruction and segmentation processing, 3D acquisition, enabled obtaining data on the masseter anatomy. The normal anatomical position of the masseter was reported to the skin plan as the mean internal distance (7.9 +/- 0.42 mm) and external distance (15.2 +/- 0.41 mm). While there was no difference between internal distance, for sex or side, the external distance was significantly (p = 0.02) shorter in male (7.7 +/- 0.5 mm) than in female (8.8 +/- 0.4 mm) for both sides. The mean volume for all subjects and both sides (20.3 +/- 1.1 cm3) did not change significantly between rest and exercise. The masseter volume was significantly (p < 0.00001) greater in male (24.2 +/- 2.0 cm3) than in female (16.4 +/- 3.6 cm3) groups. These physiological references may be useful for further MRI investigations of masticatory system pathologies.
Collapse
|
20
|
Magnetic resonance imaging for the determination of magnetic susceptibility of materials. JOURNAL OF MAGNETIC RESONANCE. SERIES B 1996; 112:111-8. [PMID: 8812894 DOI: 10.1006/jmrb.1996.0120] [Citation(s) in RCA: 54] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
A magnetic resonance imaging method for volume magnetic susceptibility estimate of materials immersed in a liquid containing resonant nuclei is proposed. The method uses either the standard spin-echo Fourier imaging technique or the projection-reconstruction technique. Image distortions of cylindrical macroscopic susceptibility inhomomogeneities are analyzed and a correlation is established between the susceptibility value and the size of image deformation along the read gradient. For measurements, the susceptibility of the liquid surrounding the sample (here deionized water) serves as a reference, and characteristic distances between particular points, usually highlights in the distorted image, are related to the susceptibility difference between the two media. Different samples, mainly prosthetic materials with a large susceptibility range from 5 to 200 ppm in absolute value, have been investigated, and the accuracy of susceptibility determination is discussed.
Collapse
|
21
|
[The demonstration of a relation between premolar force and molar force within the limits of a simplified approach to masticatory system functioning]. BULLETIN DU GROUPEMENT INTERNATIONAL POUR LA RECHERCHE SCIENTIFIQUE EN STOMATOLOGIE & ODONTOLOGIE 1996; 39:95-101. [PMID: 9273044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The purpose of this study is to show the existence of a correlation between the premolar and molar clenching forces obtained during a voluntary clenching exercise. The study concerned 32 volunteers aged 21 to 28 with no manducatory problems. The forces were obtained using a device with four Kiowa traducers arranged in a complete Wheatstone bridge. The analysis of the results obtained showed that there was a positive correlation between maximum molar and premolar. The analysis also shows that three results are a direct application of the theory of momentum. This enables us to propose a simple biophysical model to explain the functioning of the masticatory system.
Collapse
|
22
|
[The determination of the intensity of premolar and molar maximal forces during the isometric contraction of the masticatory muscles due to forced mandibular closure]. BULLETIN DU GROUPEMENT INTERNATIONAL POUR LA RECHERCHE SCIENTIFIQUE EN STOMATOLOGIE & ODONTOLOGIE 1996; 39:87-94. [PMID: 9273043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The purpose of this study to quantify the activity of the masticatory muscles. For this we recorded the maximum bite force of opposing teeth during voluntary clenching. The study was carried out on 31 students aged 21 to 28 with a satisfactory dental arch. The measurements were obtained on one side only. Nine thickness of the traducers were used for the premolar zone and two for the molar zone. We determined an optimal thickness enabling the highest measurement: 6.5 mm for the premolars and 5.2 for the molars. The highest measurements were averaged and the following results were obtained: premolars-35 kgf for females and 50 kgf for males; molars 100 kgf for females and 130 kgf for males.
Collapse
|
23
|
Correlation between magnetic resonance imaging disturbances and the magnetic susceptibility of dental materials. Dent Mater 1994; 10:265-8. [PMID: 7664995 DOI: 10.1016/0109-5641(94)90072-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
OBJECTIVES The purpose of this study was to correlate the size and the orientation of image disturbances observed on specific samples of dental materials with their magnetic susceptibility. The measurement of the magnetic susceptibility was performed in the 10(-5) or 10(-6) range using MRI to establish a classification of dental materials. METHODS Cylindrical dental alloy samples incorporating gold, silver, and palladium were placed in a Pyrex beaker filled with distilled water. Images were performed at 0.13 Tesla using two-dimensional Fourier transformation and projection reconstruction at 360 degrees imaging methods. The magnetic susceptibilities were obtained by measuring distances between spots having the highest intensity on the image. RESULTS A very discriminating classification may be established on MRI criteria. This method permits one to determine the dia- or para-magnetic character of the dental materials tested. Only palladium-based alloys have been detected to be paramagnetic with kappa > 0. One of the silver-based alloys did not induce detectable distortion because its susceptibility was very close to that of distilled water. Based on this MRI data, the use of this material may be recommended for applications that may be subjected to MRI evaluation. SIGNIFICANCE With the increasing use of MRI as a diagnostic tool, it is useful to establish a classification of prosthetic biomaterials compatible with MRI.
Collapse
|
24
|
[The value of the CO2 laser for bonding composite resins to dentin]. BULLETIN DU GROUPEMENT INTERNATIONAL POUR LA RECHERCHE SCIENTIFIQUE EN STOMATOLOGIE & ODONTOLOGIE 1994; 37:5-12. [PMID: 7994161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
CO2 laser irradiation brings about structural modifications at the dentin surface. The aim of this study was to compare the tensile strength of composite resin bonded to unlased dentin and lased dentin. Dentin specimens were prepared by vestibular surface sectioning, exposing a plane dentinal surface. 40 specimens received 20 individual laser impacts with a power of 4 W and a duration of 0.1 s. 20 specimens received no laser irradiation. Half of the 60 specimens was treated with Scotchbond 2 and the other one with Scotchbond Multipurpose. Composite cylinders were polymerised for 40 seconds to these specimens. Tensile bond strengths were determined at a crosshead speed of 5 mm/min and fractured surfaces were examined at SEM after the test. Unlased dentin had significantly higher bond strength that the lased dentin.
Collapse
|
25
|
Abstract
The aim of this in vitro study was to compare the adhesive properties of a manufacturer's third and fourth generation dentin adhesive. Vestibular sections of recently extracted third molars were embedded in chemical-cured acrylic resin and ground with 600-grit silicon carbide sandpaper. Fifteen samples were prepared with the adhesive products and the dentin surfaces were analysed by SEM. Twenty-four samples were divided into two groups and prepared with third and fourth generation systems, respectively. Composite filled tubes were then positioned on the prepared dentin surfaces and photopolymerized. The treated samples were kept in distilled water at 37 degrees C for 24 h. Four samples were used to analyze the resin-dentin surface. A tension test was performed on the remaining twenty samples at a crosshead speed of 0.5 mm/min. The results were analyzed using the Fisher and Student t-tests. The fractured surfaces were examined by SEM. The resistance to tensile forces of specimens prepared with the fourth generation system was significantly higher than that obtained after using the third generation system. Thus, as expected from the in vitro tests, the fourth generation system provided better adhesion to dentin than the third generation material.
Collapse
|
26
|
Abstract
Stress modifies numerous physiological variables, such as salivary secretion. The relation between salivary constituents, biophysical variables and personality traits defined by the Cattell's anxiety scale was studied. The main result was, that in the absence of stress, no statistically significant differences are to be found between the three groups defined on the Cattell scale.
Collapse
|
27
|
Distribution of zinc ions from orthophosphate cements at the cement-tooth interface in fixed dental prosthesis. Biomaterials 1993; 14:770-4. [PMID: 8218727 DOI: 10.1016/0142-9612(93)90042-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Cast metal prostheses are considered to be one of the best ways to restore the morphology and function of missing teeth. However, the success of fixed prosthesis therapy is mainly to be judged on its durability. It is therefore important to know how cemented prostheses behave in the mouth. A protocol for an in vivo study was set up to analyse the influence of time on the release of zinc ions from zinc orthophosphate cements used at the tooth-prosthesis interface.
Collapse
|
28
|
Disturbances caused by dental materials in magnetic resonance imaging. Int Dent J 1992; 42:229-33. [PMID: 1399040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Nuclear Magnetic Resonance (NMR) is the latest addition to medical imaging technology. This technique plays an important role in head and neck diagnosis. Radiologists may encounter patients with fixed dental prostheses that may produce image distortion on MRI scans of the face. The MRI appearances of dental prosthetic materials was studied in vitro, including precious alloys, non-precious alloys, ceramic prostheses, dental amalgam and composite materials. It was found that non-precious alloys produce large image deformations, whereas precious alloys had no effect on MRI images. An in vivo study showed the anatomical zones that were most affected on MRI scans.
Collapse
|
29
|
Abstract
Radiologists may encounter patients with fixed dental prostheses that may produce image distortion on MRI scans of the face and jaw. In this work, we assessed the MRI appearances of dental prosthetic materials in vitro, including precious alloys, nonprecious alloys, ceramic prostheses, dental amalgam, and composite materials. For in vivo studies, these materials were placed in the patient's mouth. Nonprecious alloys produce large image deformations, whereas precious alloys had no effect on MRI images. The in vivo study showed the anatomical zones that were most affected on MRI scans. The size of these zones produced by the presence of nonprecious alloys is influenced by the volume of the prosthesis and is related to the scanning sequence used.
Collapse
|
30
|
Radioisotopic and biochemical determination of salivary secretion after long term psychotropic therapy. INTERNATIONAL JOURNAL OF RADIATION APPLICATIONS AND INSTRUMENTATION. PART B, NUCLEAR MEDICINE AND BIOLOGY 1990; 17:255-8. [PMID: 2160445 DOI: 10.1016/0883-2897(90)90155-t] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The aim of this work was to investigate the effect of prolonged psychotropic therapy (neuroleptics and antidepressants over 5 yr on salivary secretion. The flow rate in the parotid and submandibular glands were measured separately by scintigraphy. Flow rates, total protein concentration and total IgA level were determined in the unstimulated saliva in 30 control subjects and 73 patients treated with psychotropic drugs. As evidenced by measurement of flow rates and scintigraphy, psychotropic therapy reduced the unstimulated salivary secretion from parotid glands and to a lesser extent from submandibular gland. The scintigraphic study showed a lower response to stimulation in patients than controls.
Collapse
|
31
|
Abstract
Relaxation times T1 and T2 of water protons for stimulated and unstimulated parotid and submandibular saliva from healthy patients were measured in the conventional way using the Bruker PC 20 Minispec. Some measurements of dispersion were also carried out. An interpretation of the average values for T1 and T2 observed in the 20 MHz range is proposed for these types of saliva in relation to biochemical composition (total proteins, amylase activity, sialic acids and hexosamins) and viscosity. For parotid saliva T2(-1)-T1(-1) correlates significantly with amylase activity. In the submandibular saliva T2(-1)-T1(-1) correlates significantly with both mucins and alpha-amylase activity.
Collapse
|
32
|
Abstract
This device has collecting cups which follow the movements of the floor of the mouth but which is kept stationary by a fixed platform on the occlusal surfaces of the teeth. The appliance can be adapted to different dental morphologies.
Collapse
|