1
|
Coronary Microvascular Dysfunction in Acute Cholestasis-Induced Liver Injury. Biomedicines 2024; 12:876. [PMID: 38672230 PMCID: PMC11048529 DOI: 10.3390/biomedicines12040876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/08/2024] [Accepted: 04/14/2024] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Previous studies have shown cardiac abnormalities in acute liver injury, suggesting a potential role in the associated high mortality. METHODS We designed an experimental study exploring the short-term effects of acute cholestasis-induced liver injury on cardiac function and structure in a rodent bile duct ligation (BDL) model to elucidate the potential interplay. Thirty-seven male Sprague-Dawley rats were subjected to BDL surgery (n = 28) or served as sham-operated (n = 9) controls. Transthoracic echocardiography, Doppler evaluation of the left anterior descending coronary artery, and myocardial contrast echocardiography were performed at rest and during adenosine and dobutamine stress 5 days after BDL. Immunohistochemical staining of myocardial tissue samples for hypoxia and inflammation as well as serum analysis were performed. RESULTS BDL animals exhibited acute liver injury with elevated transaminases, bilirubin, and total circulating bile acids (TBA) 5 days after BDL (TBA control: 0.81 ± 2.54 µmol/L vs. BDL: 127.52 ± 57.03 µmol/L; p < 0.001). Concurrently, cardiac function was significantly impaired, characterized by reduced cardiac output (CO) and global longitudinal strain (GLS) in the echocardiography at rest and under pharmacological stress (CO rest control: 120.6 ± 24.3 mL/min vs. BDL 102.5 ± 16.6 mL/min, p = 0.041; GLS rest control: -24.05 ± 3.8% vs. BDL: -18.5 ± 5.1%, p = 0.01). Myocardial perfusion analysis revealed a reduced myocardial blood flow at rest and a decreased coronary flow velocity reserve (CFVR) under dobutamine stress in the BDL animals (CFVR control: 2.1 ± 0.6 vs. BDL: 1.7 ± 0.5 p = 0.047). Immunofluorescence staining indicated myocardial hypoxia and increased neutrophil infiltration. CONCLUSIONS In summary, acute cholestasis-induced liver injury can lead to impaired cardiac function mediated by coronary microvascular dysfunction, suggesting that major adverse cardiac events may contribute to the mortality of acute liver failure. This may be due to endothelial dysfunction and direct bile acid signaling.
Collapse
|
2
|
Choice of Polymer, but Not Mesh Structure Variation, Reduces the Risk of Bacterial Infection with Staphylococcus aureus In Vivo. Biomedicines 2023; 11:2083. [PMID: 37509722 PMCID: PMC10377515 DOI: 10.3390/biomedicines11072083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 07/17/2023] [Accepted: 07/21/2023] [Indexed: 07/30/2023] Open
Abstract
BACKGROUND Synthetic mesh material is of great importance for surgical incisional hernia repair. The physical and biochemical characteristics of the mesh influence mechanical stability and the foreign body tissue reaction. The influence on bacterial infections, however, remains ill-defined. The aim of the present study was to evaluate the influence of a modified mesh structure with variation in filament linking on the occurrence of bacterial infection that is indicated by the occurrence of CD68+, CD4+, and CD8+ cells in two different materials. METHODS A total of 56 male Sprague Dawley rats received a surgical mesh implant in a subcutaneous abdominal position. The mesh of two different polymers (polypropylene (PP) and polyvinylidenfluoride (PVDF)) and two different structures (standard structure and bold structure with higher filament linking) were compared. During the implantation, the meshes were infected with Staphylococcus (S.) aureus. After 7 and 21 days, meshes were explanted, and the early and late tissue responses to infection were histologically evaluated. RESULTS Overall, the inflammatory tissue response was higher at 7 days when compared to 21 days. At 7 days, PP meshes of the standard structure (PP-S) showed the strongest inflammatory tissue response in comparison to all the other groups. At 21 days, no statistically significant difference between different meshes was detected. CD8+ cytotoxic T cells showed a significant difference at 21 days but not at 7 days. PP meshes of both structures showed a higher infiltration of CD8+ T cells than PVDF meshes. CD4+ T helper cells differed at 7 days but not at 21 days, and PVDF meshes in a bold structure showed the highest CD4+ T cell count. The number of CD68+ macrophages was also significantly higher in PP meshes in a standard structure when compared to PVDF meshes at 21 days. CONCLUSION The inflammatory tissue response to S. aureus infection appears to be highest during the early period after mesh implantation. PP meshes showed a higher inflammatory response than PVDF meshes. The mesh material appears to be more important for the risk of infection than the variation in filament linking.
Collapse
|
3
|
Experimental Liver Cirrhosis Inhibits Restenosis after Balloon Angioplasty. Int J Mol Sci 2023; 24:11351. [PMID: 37511114 PMCID: PMC10379020 DOI: 10.3390/ijms241411351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/09/2023] [Accepted: 07/10/2023] [Indexed: 07/30/2023] Open
Abstract
The effect of liver cirrhosis on vascular remodeling in vivo remains unknown. Therefore, this study investigates the influence of cholestatic liver cirrhosis on carotid arterial remodeling. A total of 79 male Sprague Dawley rats underwent bile duct ligation (cirrhotic group) or sham surgery (control group) and 28 days later left carotid artery balloon dilatation; 3, 7, 14 and 28 days after balloon dilatation, the rats were euthanized and carotid arteries were harvested. Histological sections were planimetrized, cell counts determined, and systemic inflammatory parameters measured. Up to day 14 after balloon dilatation, both groups showed a comparable increase in neointima area and degree of stenosis. By day 28, however, both values were significantly lower in the cirrhotic group (% stenosis: 20 ± 8 vs. 42 ± 10, p = 0.010; neointimal area [mm2]: 0.064 ± 0.025 vs. 0.138 ± 0.025, p = 0.024). Simultaneously, cell density in the neointima (p = 0.034) and inflammatory parameters were significantly higher in cirrhotic rats. This study demonstrates that cholestatic liver cirrhosis in rats substantially increases neointimal cell consolidation between days 14 and 28. Thereby, consolidation proved important for the degree of stenosis. This may suggest that patients with cholestatic cirrhosis are at lower risk for restenosis after coronary intervention.
Collapse
|
4
|
Cirrhotic Cardiomyopathy Following Bile Duct Ligation in Rats-A Matter of Time? Int J Mol Sci 2023; 24:ijms24098147. [PMID: 37175858 DOI: 10.3390/ijms24098147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 04/28/2023] [Accepted: 04/30/2023] [Indexed: 05/15/2023] Open
Abstract
Cirrhotic patients often suffer from cirrhotic cardiomyopathy (CCM). Previous animal models of CCM were inconsistent concerning the time and mechanism of injury; thus, the temporal dynamics and cardiac vulnerability were studied in more detail. Rats underwent bile duct ligation (BDL) and a second surgery 28 days later. Cardiac function was assessed by conductance catheter and echocardiography. Histology, gene expression, and serum parameters were analyzed. A chronotropic incompetence (Pd31 < 0.001) and impaired contractility at rest and a reduced contractile reserve (Pd31 = 0.03, Pdob-d31 < 0.001) were seen 31 days after BDL with increased creatine (Pd35, Pd42, and Pd56 < 0.05) and transaminases (Pd31 < 0.001). A total of 56 days after BDL, myocardial fibrosis was seen (Pd56 < 0.001) accompanied by macrophage infiltration (CD68: Pgroup < 0.001) and systemic inflammation (TNFα: Pgroup < 0.001, white blood cell count: Pgroup < 0.001). Myocardial expression of peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC1α) was increased after 31 (Pd31 < 0.001) and decreased after 42 (Pd42 < 0.001) and 56 days (Pd56 < 0.001). Caspase-3 expression was increased 31 and 56 days after BDL (Pd31 = 0.005; Pd56 = 0.005). Structural changes in the myocardium were seen after 8 weeks. After the second surgery (second hit), transient myocardial insufficiency with secondary organ dysfunction was seen, characterized by reduced contractility and contractile reserve.
Collapse
|
5
|
A Deep-Learning-Computed Cancer Score for the Identification of Human Hepatocellular Carcinoma Area Based on a Six-Colour Multiplex Immunofluorescence Panel. Cells 2023; 12:cells12071074. [PMID: 37048147 PMCID: PMC10093209 DOI: 10.3390/cells12071074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/25/2023] [Accepted: 04/01/2023] [Indexed: 04/05/2023] Open
Abstract
Liver cancer is one of the most frequently diagnosed and fatal cancers worldwide, with hepatocellular carcinoma (HCC) being the most common primary liver cancer. Hundreds of studies involving thousands of patients have now been analysed across different cancer types, including HCC, regarding the effects of immune infiltrates on the prognosis of cancer patients. However, for these analyses, an unambiguous delineation of the cancer area is paramount, which is difficult due to the strong heterogeneity and considerable inter-operator variability induced by qualitative visual assessment and manual assignment. Nowadays, however, multiplex analyses allow the simultaneous evaluation of multiple protein markers, which, in conjunction with recent machine learning approaches, may offer great potential for the objective, enhanced identification of cancer areas with further in situ analysis of prognostic immune parameters. In this study, we, therefore, used an exemplary five-marker multiplex immunofluorescence panel of commonly studied markers for prognosis (CD3 T, CD4 T helper, CD8 cytotoxic T, FoxP3 regulatory T, and PD-L1) and DAPI to assess which analytical approach is best suited to combine morphological and immunohistochemical data into a cancer score to identify the cancer area that best matches an independent pathologist’s assignment. For each cell, a total of 68 individual cell features were determined, which were used as input for 4 different approaches for computing a cancer score: a correlation-based selection of individual cell features, a MANOVA-based selection of features, a multilayer perceptron, and a convolutional neural network (a U-net). Accuracy was used to evaluate performance. With a mean accuracy of 75%, the U-net was best capable of identifying the cancer area. Although individual cell features showed a strong heterogeneity between patients, the spatial representations obtained with the computed cancer scores delineate HCC well from non-cancer liver tissues. Future analyses with larger sample sizes will help to improve the model and enable direct, in-depth investigations of prognostic parameters, ultimately enabling precision medicine.
Collapse
|
6
|
Influence of polypropylene mesh degradation on tissue inflammatory reaction. J Biomed Mater Res A 2022. [PMID: 36583666 DOI: 10.1002/jbm.a.37494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 12/14/2022] [Accepted: 12/20/2022] [Indexed: 12/31/2022]
Abstract
Polypropylene degradation in vivo appears as mesh surface cracking and peeling. This aging process of the mesh, resulting in the lack of bio-stability, contradicts the requirement of biocompatibility. However, to date, it is still not clearly established how much this mesh degradation influences the local tissue response with subsequent clinical consequences. This study aims to find out whether mesh degradation is correlated with elevated inflammatory tissue reaction through analyzing 100 human PP meshes explanted from the pelvic floor. A degradation classification method, based on standard pathological H&E stained slides of the explanted mesh via light microscope, was developed to classify the mesh degradation into four classes (no, mild, moderate and severe degradation). The peri-filamentary tissue inflammatory reaction was analyzed by scoring the expression of the most common cell markers for the innate immune reaction: CD68 as marker for macrophage, CD86 for M1 subtype, CD163 for M2 subtype, CD3 for T-lymphocyte and CD15 for neutrophil granulocytes. The correlation between immune cell expression, degradation classification and time of implantation of the meshes are evaluated with Spearman-Rho-Test. Mesh degradation worsens significantly (p < .001) with longer time of implantation. The increasing tendency of CD68 expression by mesh with higher degradation class indicates that the number of macrophages increases with worsening mesh degradation. The significantly increased expression of CD163 and CD3 cell by severely degraded mesh demonstrate the increased number of M2 and T-Lymphocyte when mesh degradation becomes severe. None of the inflammatory cells show the usual declining expression with longer time of implantation. The result of this study suggests that the degradation of PP mesh results in an elevated local inflammatory reaction in female pelvic floor. A material with better bio-stability for mesh implant in pelvic floor is required.
Collapse
|
7
|
PD-1+ T-Cells Correlate with Nerve Fiber Density as a Prognostic Biomarker in Patients with Resected Perihilar Cholangiocarcinoma. Cancers (Basel) 2022; 14:cancers14092190. [PMID: 35565318 PMCID: PMC9103905 DOI: 10.3390/cancers14092190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/15/2022] [Accepted: 04/19/2022] [Indexed: 12/10/2022] Open
Abstract
Simple Summary Recent studies have identified Nerve Fiber Density (NFD) as a prognostic biomarker for Cholangiocarcinoma (CCA). In the field of CCA treatment with checkpoint inhibitors (ICI) is increasing but not all patients respond. Good biomarkers to predict response to ICI are lacking. The present study investigates the immune cell composition and expression of checkpoint molecules in relation to NFD in perihilar cholangiocarcinoma (pCCA) patients. Our study identified NFD to correlate with PD-1+ T cells as a biomarker indicative for a good prognosis. Abstract Background and Aims: Perihilar cholangiocarcinoma (pCCA) is a hepatobiliary malignancy, with a dismal prognosis. Nerve fiber density (NFD)—a novel prognostic biomarker—describes the density of small nerve fibers without cancer invasion and is categorized into high numbers and low numbers of small nerve fibers (high vs low NFD). NFD is different than perineural invasion (PNI), defined as nerve fiber trunks invaded by cancer cells. Here, we aim to explore differences in immune cell populations and survival between high and low NFD patients. Approach and Results: We applied multiplex immunofluorescence (mIF) on 47 pCCA patients and investigated immune cell composition in the tumor microenvironment (TME) of high and low NFD. Group comparison and oncological outcome analysis was performed. CD8+PD-1 expression was higher in the high NFD than in the low NFD group (12.24 × 10−6 vs. 1.38 × 10−6 positive cells by overall cell count, p = 0.017). High CD8+PD-1 expression was further identified as an independent predictor of overall (OS; Hazard ratio (HR) = 0.41; p = 0.031) and recurrence-free survival (RFS; HR = 0.40; p = 0.039). Correspondingly, the median OS was 83 months (95% confidence interval (CI): 18–48) in patients with high CD8+PD-1+ expression compared to 19 months (95% CI: 5–93) in patients with low CD8+PD-1+ expression (p = 0.018 log rank). Furthermore, RFS was significantly lower in patients with low CD8+PD-1+ expression (14 months (95% CI: 6–22)) compared to patients with high CD8+PD-1+ expression (83 months (95% CI: 17–149), p = 0.018 log rank). Conclusions: PD-1+ T-cells correlate with high NFD as a prognostic biomarker and predict good survival; the biological pathway needs to be investigated.
Collapse
|
8
|
Quantitative Characterization of Macrophage, Lymphocyte, and Neutrophil Subtypes Within the Foreign Body Granuloma of Human Mesh Explants by 5-Marker Multiplex Fluorescence Microscopy. Front Med (Lausanne) 2022; 9:777439. [PMID: 35242772 PMCID: PMC8887619 DOI: 10.3389/fmed.2022.777439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 01/11/2022] [Indexed: 11/13/2022] Open
Abstract
Foreign bodies such as fibers of a surgical mesh induce a typical reaction with an inflammatory infiltrate that forms a surrounding granuloma. This infiltrate is dominated by macrophages, lymphocytes, and neutrophils, whereas its extent of collaboration is widely unknown. In this study, we analyzed 12 samples of surgical meshes explanted from humans by multiplex analyses with three different 5-marker panels – 1. macrophage panel: CD68, CD86, CD105, CD163, and CD206; 2. lymphocyte panel: CD3, CD4, CD8, CD20, and CD68; and 3. neutrophil panel: CD15, histone, MPO, NE, and CD68. Measurement of fluorescence intensity within nuclear masks resulting from DAPI nuclear staining allows exact quantification of cells considered “positive” at a user-defined mean intensity threshold of > 100. Obviously, however, there is no natural threshold as a biological criterion for an intensity that separates “positive” stained cells from unstained cells (“negative”). Multiplex staining of 5 markers always reveals a high rate of coexpression for almost all of the 25 possible marker combinations (= 32 combinations, when using 5 markers simultaneously). The present staining results demonstrate that various morphological and functional subtypes of macrophages, lymphocytes, and neutrophils are abundant in the foreign body granuloma (FBG), which were investigated by regions of interest (ROI) with an area of 1 mm2. The widespread coexpression of two or more markers underscores the complex collaboration network of the inflammatory infiltrate. The ability to combine spatial distribution with exact numerical analysis may offer new perspectives for our understanding of the complex interactions in this multidimensional process.
Collapse
|
9
|
P042 CHARACTERIZATION OF INNATE AND ADAPTIVE IMMUNE CELLS INVOLVED IN THE FOREIGN BODY REACTION TO POLYPROPYLENE MESHES IN THE HUMAN ABDOMEN. Br J Surg 2021. [DOI: 10.1093/bjs/znab395.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Abstract
Aim
Polypropylene (PP) mesh is widely used to reinforce tissues. The foreign body reaction (FBR) to the implant is dominated by innate immune cells, especially macrophages. However, considerable numbers of adaptive immune cells have also been regularly observed, which appear to play a crucial role in the long-term host response. This study investigated the FBR to seven human PP meshes, which were removed from the abdomen for recurrence after a median of one year.
Material and Methods
Using immunofluorescence microscopy and distance maps, the FBR was spatially analyzed for various innate (e.g., CD68+ macrophages, CD56+ NK) and adaptive immune cells (CD3+ T, CD4+ T-helper, CD8+ cytotoxic, FoxP3+ T-regulatory, CD20+ B) as well as “conventional” immune cells (defined as cells expressing their specific immune cell marker without co-expressing CD68).
Results
T-helper cells (19%) and regulatory T-cells (25%) were present at comparable rates to macrophages, and clustered significantly toward the mesh fibers. For all cell types the lowest proportions of “conventional” cells (< 60%) were observed at the mesh–tissue interface, but increased considerably at about 50–100 µm, indicating reduced stimulation with rising distance to the mesh fibers.
Conclusions
Both innate and adaptive immune cells participate in the chronic FBR to PP meshes with T cells and macrophages being the predominant cell types, respectively. Furthermore, many cells present a “hybrid” pattern near the mesh fibers. The complexity of the local immune reaction may explain why approaches focusing on specific cell types have not been very successful in reducing the chronic FBR.
Collapse
|
10
|
Acute myocardial injury secondary to severe acute liver failure: A retrospective analysis supported by animal data. PLoS One 2021; 16:e0256790. [PMID: 34460845 PMCID: PMC8405020 DOI: 10.1371/journal.pone.0256790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 08/17/2021] [Indexed: 11/29/2022] Open
Abstract
To investigate whether acute liver failure (ALF) leads to secondary acute myocardial injury, 100 ALF patients that were retrospectively identified in a single center based on ICD 10 codes and 8 rats from an experimental study that died early after bile duct ligation (BDL) were examined. Creatine kinase (CK), creatine kinase-MB isoenzyme (CKMB) and cardiac troponin-I (cTnI) were analyzed as markers of myocardial injury. For histological analysis, hematoxylin-eosin (HE), elastic Van Gieson (EVG), CD41 and myeloperoxidase were used to stain rat hearts. Major adverse cardiac events (MACEs) were a critical factor for mortality (p = 0.037) in human ALF. Deceased patients exhibited higher levels of CKMB than survivors (p = 0.023). CKMB was a predictor of mortality in ALF (p = 0.013). Animals that died early after BDL exhibited increased cTnI, CKMB, tumor necrosis factor α (TNFα) and interleukin-6 (IL-6) levels compared to controls (cTnI: p = 0.011, CKMB: p = 0.008, TNFα: p = 0.003, IL-6: p = 0.006). These animals showed perivascular lesions and wavy fibers, microthrombi and neutrophilic infiltration in the heart. MACEs are decisive for mortality in human ALF, and elevated CKMB values indicate that this might be due to structural myocardial damage. Accordingly, CKMB was found to have predictive value for mortality in ALF. The results are substantiated by data from a rat BDL model demonstrating diffuse myocardial injury.
Collapse
|
11
|
META Score: An International Consensus Scoring System on Mesh-Tissue Adhesions. World J Surg 2021; 44:2935-2943. [PMID: 32621037 DOI: 10.1007/s00268-020-05568-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Currently, the lack of consensus on postoperative mesh-tissue adhesion scoring leads to incomparable scientific results. The aim of this study was to develop an adhesion score recognized by experts in the field of hernia surgery. METHODS Authors of three or more previously published articles on both mesh-tissue adhesion scores and postoperative adhesions were marked as experts. They were queried on seven items using a modified Delphi method. The items concerned the utility of adhesion scoring models, the appropriateness of macroscopic and microscopic variables, the range and use of composite scores or subscores, adhesion-related complications and follow-up length. This study comprised two questionnaire-based rounds and one consensus meeting. RESULTS The first round was completed by 23 experts (82%), the second round by 18 experts (64%). Of those 18 experts, ten were able to participate in the final consensus meeting and all approved the final proposal. From a total of 158 items, consensus was reached on 90 items. The amount of mesh surface covered with adhesions, tenacity and thickness of adhesions and organ involvement was concluded to be a minimal set of variables to be communicated separately in each future study on mesh adhesions. CONCLUSION The MEsh Tissue Adhesion scoring system is the first consensus-based scoring system with a wide backing of renowned experts and can be used to assess mesh-related adhesions. By including this minimal set of variables in future research interstudy comparability and objectivity can be increased and eventually linked to clinically relevant outcomes.
Collapse
|
12
|
Abstract
BACKGROUND The current standard for open and laparoscopic repair of incisional hernia consist of an abdominal wall augmentation by mesh implantation. However, the ideal fixation method of the prothesis material remains under discussion, due to potential complications of conventional fixation methods such as chronic abdominal pain or intestinal obstruction. As the use of adhesive based mesh fixation is an option of growing interest, the aim of this experimental study was to investigate the strength and biocompatibility of two newly developed polyurethane-based adhesives in comparison to a cyanoacrylatic adhesive, which is currently in clinical use. METHODS Two experimental polyurethane/urea-based adhesives (Adhesive-A and Adhesive-B) were compared to a conventional cyanoacrylatic adhesive and an untreated control group. Biomechanical testing was carried out using a pull-out test in uniaxial tensile mode, while biocompatibility assessment was performed in a rat model with 40 Sprague-Dawley rats receiving a subcutaneous implanted PVDF mesh fixed by the corresponding adhesive. Histological and immunohistochemical analysis by a Tissue FAXS system examined the tissue integration of the mesh/adhesive combination and characterized the foreign body reaction. RESULTS Biomechanical testing of the mesh/adhesive combinations showed a minimal strength of 15.08 N without a significant difference between the groups. Cellular penetration into the mesh/adhesive interface was significantly improved after application of polyurethane adhesives and Adhesive-A showed a significantly lower migration of CD68 positive cells to the adhesive sites compared to cyanoacrylate after 7 days. CONCLUSION The developed polyurethane-based adhesives are a promising alternative with sufficient adhesive strength and superior short-term biocompatibility to cyanoacrylate.
Collapse
|
13
|
A peritoneal defect covered by intraperitoneal mesh prosthesis effects an increased and distinctive foreign body reaction in a minipig model. J Biomater Appl 2020; 35:732-739. [PMID: 33331198 DOI: 10.1177/0885328220963918] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The incidence of incisional hernia is with up to 30% one of the frequent long-term complication after laparotomy. After establishing minimal invasive operations, the laparoscopic intraperitoneal onlay mesh technique (lap. IPOM) was first described in 1993. Little is known about the foreign body reaction of IPOM-meshes, which covered a defect of the parietal peritoneum. This is becoming more important, since IPOM procedure with peritoneal-sac resection and hernia port closing (IPOM plus) is more frequently used. METHODS In 18 female minipigs, two out of three Polyvinylidene-fluoride (PVDF) -meshes (I: standard IPOM; II: IPOM with modified structure [bigger pores]; III: IPOM with the same structure as IPOM II + degradable hydrogel-coating) were placed in a laparoscopic IPOM procedure. Before mesh placement, a 2x2cm peritoneal defect was created. After 30 days, animals were euthanized, adhesions were evaluated by re-laparoscopy and mesh samples were explanted for histological and immunohistochemichal investigations. RESULTS All animals recovered after implantation and had no complications during the follow-up period. Analysing foreign body reaction, the IPOM II mesh had a significant smaller inner granuloma, compared to the other meshes (IPOM II: 8.4 µm ± 1.3 vs. IPOM I 9.1 µm ± 1.3, p < 0.001). The degradable hydrogel coating does not prevent adhesions measured by Diamond score (p = 0.46). A peritoneal defect covered by a standard or modified IPOM mesh was a significant factor for increasing foreign body granuloma, the amount of CD3+ lymphocytes, CD68+ macrophages and decrease of pore size. CONCLUSION A peritoneal defect covered by IPOM prostheses leads to an increased foreign body reaction compared to intact peritoneum. Whenever feasible, a peritoneal defect should be closed accurately before placing an IPOM-mesh to avoid an excessive foreign body reaction and therefore inferior biomaterial properties of the prosthesis.
Collapse
|
14
|
CD68+ macrophages as crucial components of the foreign body reaction demonstrate an unconventional pattern of functional markers quantified by analysis with double fluorescence staining. J Biomed Mater Res B Appl Biomater 2020; 108:3134-3146. [PMID: 32475069 DOI: 10.1002/jbm.b.34639] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 04/20/2020] [Accepted: 05/09/2020] [Indexed: 02/06/2023]
Abstract
Implants like meshes for the reinforcement of tissues implement the formation of a persistent inflammation with an ambient fibrotic reaction. In the inflammatory infiltrate several distinct cell types have been identified, but CD68+ macrophages are supposed to be most important. To investigate the collaboration among the various cell types within the infiltrate we performed at explanted meshes from humans double fluorescence staining with CD68 as a constant marker and a variety of other antibodies as the second marker. The list of second markers includes lymphocytes (CD3, CD4, CD8, CD16, CD56, FoxP3, and CD11b) stem cells (CD34), leucocytes (CD45, CD15), macrophages (CD86, CD105, CD163, and CD206); deposition of EC matrix (collagen-I, collagen-III, MMP2, and MMP8); Ki67 as a marker for proliferation; and the tyrosine-protein kinase receptor AXL. The present study demonstrates within the inflammatory infiltrate the abundant capability of CD68+ cells to co-express a huge variety of other markers, including those of lymphocytes, varying between 5 and 83% of investigated cells. The observation of co-staining was not restricted to a specific polymer but was seen with polypropylene fibers as well as with fibers made of polyvinylidene fluoride, although with differences in co-expression rates. The persisting variability of these cells without the functional reduction toward differentiated mature cell types may favor the lack of healing at the interface of meshes.
Collapse
|
15
|
Improved tissue integration of a new elastic intraperitoneal stoma mesh prosthesis. J Biomed Mater Res B Appl Biomater 2020; 108:2250-2257. [PMID: 31967402 DOI: 10.1002/jbm.b.34562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Revised: 12/03/2019] [Accepted: 01/08/2020] [Indexed: 11/06/2022]
Abstract
Parastomal herniation is a frequent complication in colorectal surgery, occurring with a prevalence of 30-80%. The aim of the study was to create a new intraperitoneal colostoma mesh prosthesis (IPST) with enhanced elastic properties made with thermoplastic polyurethane (TPU) monofilaments. We performed open terminal sigmoid colostomies reinforced with either a 10 cm by 10 cm polyvinylidene fluoride (PVDF) or a new TPU/PVDF composite mesh in a total of 10 minipigs. Colostoma was placed paramedian in the left lower abdomen and IPST meshes were fixed intraperitoneal. After 8 weeks, the animals were euthanized after laparoscopic exploration and specimen were explanted for histological investigations. Implantation of a new IPST-mesh with enhanced elastic properties was feasible in a minipig model within an observation period of 8 weeks. Immunohistochemically, Collagen I/III ratio as a marker of tissue integration was significantly higher in TPU-group versus PVDF group (9.4 ± 0.5 vs. 8.1 ± 0.5, p = 0.002) with a significantly lower inflammatory reaction measured by a smaller inner granuloma at mesh-colon interface (17.6 ± 3.3 μm vs. 23 ± 5 μm, p < 0.001). A new TPU/PVDF composite mesh with enhanced elastic properties as IPST was created. Stoma surgery and especially the evaluation of the new stoma mesh prosthesis are feasible with reproducible results in an animal model. Tissue integration expressed by Collagen I/III ratio seems to be improved in comparison to standard-elastic PVDF-IPST meshes.
Collapse
|
16
|
Follow Up Data of MRI-Visible Synthetic Meshes for Reinforcement in Large Hiatal Hernia in Comparison to None-Mesh Repair-A Prospective Cohort Study. Front Surg 2019; 6:17. [PMID: 31058163 PMCID: PMC6477929 DOI: 10.3389/fsurg.2019.00017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Accepted: 03/18/2019] [Indexed: 11/13/2022] Open
Abstract
Background: Mesh augmentation for large hiatal hernia is still controversial because of high alleged risk of chronic reaction or shrinkage of mesh orifice surrounding the esophagus. The aim of this cohort study was to develop and establish an image analysis scheme, including 3D reconstruction, for MRI-visible meshes (DynaMesh®) to measure postoperative mesh shrinkage in order to observe potential complications. Methods: Between 12/2012 and 10/2016, n = 33 patients underwent surgery to correct symptomatic hiatal hernia (implantation indicated: n = 18). Intraoperative measurement of the hiatal surface area (HSA) > 5 cm2 was indication for mesh implantation. Early postoperatively, and during long-term follow-up, MRI was performed and patients filled out the gastrointestinal quality of life index (GIQLI score). Results: Follow-up rate was 76% (n = 25/33). Overall recurrence rate was 4% (1/25). No other patient showed reflux or dysphagia symptoms. Mesh related complications were not observed during follow-up period. Median GIQLI score of patients with mesh was 123 (range: 67-144), and 93 (52-141) for patients without mesh. Comparison of early and mid-term postoperative MRI for patients with mesh showed changes in mesh orifice size of 3% (corresponding to a slight increase in size of about 6 mm2) without any significant correlations with BMI, HSA, or patient age. Conclusion: We established an image analysis and 3D reconstruction scheme for MRI visible meshes in hiatal hernia repair. MRI images of normal clinical quality are sufficient for this analysis. Mesh orifice size in MRI-visible meshes does not seem to change at a clinically relevant level in the small cohort observed here. Further studies of large cohorts are necessary to establish if HSA >5 cm2 could be a suitable measure for indication of mesh implantation.
Collapse
|
17
|
The Impact of a Nitric Oxide Synthase Inhibitor (L-NAME) on Ischemia⁻Reperfusion Injury of Cholestatic Livers by Pringle Maneuver and Liver Resection after Bile Duct Ligation in Rats. Int J Mol Sci 2019; 20:ijms20092114. [PMID: 31035686 PMCID: PMC6539833 DOI: 10.3390/ijms20092114] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 04/19/2019] [Accepted: 04/24/2019] [Indexed: 02/07/2023] Open
Abstract
The Pringle maneuver (PM) has been widely used to control blood loss during liver resection. However, hepatic inflow occlusion can also result in hepatic ischemia–reperfusion injury (IRI), especially in patients with a cholestatic, fibrotic, or cirrhotic liver. Here we investigate a nitric oxide synthase (NOS) inhibitor N-Nitroarginine methyl ester (L-NAME) on IRI after the PM and partial hepatectomy of cholestatic livers induced by bile duct ligation (BDL) in rats. Control group (non-BDL/no treatment), BDL + T group (BDL/L-NAME treatment) and BDL group (BDL/no treatment) were analyzed. Cholestasis was induced by BDL in the L-NAME and BDL group and a 50% partial hepatectomy with PM was performed. L-NAME was injected before PM in the BDL + T group. Hepatocellular damage, portal venous flow, microcirculation, endothelial lining, and eNOS, iNOS, interleukin (IL)-6, and transforming growth factor-β (TGF-β) were evaluated. Microcirculation of the liver in the BDL + T group tended to be higher. Liver damage and apoptotic index were significantly lower and Ki-67 labeling index was higher in the BDL + T group while iNOS and TGF-β expression was decreased. This was corroborated by a better preserved endothelial lining. L-NAME attenuated IRI following PM and improved proliferation/regeneration of cholestatic livers. These positive effects were considered as the result of improved hepatic microcirculation, prevention of iNOS formation, and TGF-β mRNA upregulation.
Collapse
|
18
|
Abstract
INTRODUCTION Today the use of textile meshes has become a standard for the treatment of abdominal wall hernias and for the reinforcement of any tissue repair as the strength of the implant decreases the recurrence rates. With increasing use, side effects of the textile implants became apparent, as well. AREAS COVERED Based on publications in Medline over the past decade, general and specific benefits, as well as risks, are discussed with the challenge to define individual risk-benefit ratios. For meshes, certain high-risk or low-risk conditions can be defined. In an attempt to eliminate mesh-related risks, quality control for medical devices has meanwhile been revised. In both the USA and the EU post-market surveillance studies are required to keep medical devices approved. EXPERT COMMENTARY The impact of material on the complication rate will vary depending on the patient's co-morbidity or the risks of the procedure. Even the best material can end up with disappointing results in case of poor healing or poor surgery. On the other hand, when using high-risk devices, most of the complications after excellent surgery with excellent indication can be supposed to be mesh-related. Thus, the use of low-risk devices is recommended even though its advantage may not be demonstrable in clinical studies.
Collapse
|
19
|
Abstract
Background: The open abdomen with mesh implantation, followed by early reoperation with fascial closure, is a modern surgical approach in difficult clinical situations such as severe abdominal sepsis. As early fascial closure is not possible in many cases, mesh-mediated fascial traction is helpful for conditioning of a minimized ventral hernia after open abdomen. The aim of this study was to evaluate the clinical utilization of an innovative elastic thermoplastic polyurethane mesh (TPU) as an abdominal wall inlay in a minipig model. Methods: Ten minipigs were divided in two groups, either receiving an elastic TPU mesh or a nonelastic polyvinylidene fluoride (PVDF) mesh in inlay position of the abdominal wall. After 8 weeks, mesh expansion and abdominal wall defect size were measured. Finally, pigs were euthanized and abdominal walls were explanted for histological and immunohistochemical assessment. Results: Eight weeks after abdominal wall replacement, transversal diameter of the fascial defect in the TPU group was significantly smaller than in the PVDF group (4.5 cm vs. 7.4 cm; p = 0.047). Immunhistochemical analysis showed increased Ki67 positive cells (p = 0.003) and a higher number of apoptotic cells (p = 0.047) after abdominal wall replacement with a TPU mesh. Collagen type I/III ratio was increased in the PVDF group (p = 0.011). Conclusion: Implantation of an elastic TPU mesh as abdominal wall inlay is a promising approach to reduce the size of the ventral hernia after open abdomen by mesh-mediated traction. However, this effect was associated with a slightly increased foreign body reaction in comparison to the nonelastic PVDF.
Collapse
|
20
|
AK03, a new recombinant fibrinogenase prevents abdominal adhesions in a rat model without systemic side effects. J Surg Res 2017; 222:85-92. [PMID: 29273379 DOI: 10.1016/j.jss.2017.09.047] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 09/20/2017] [Accepted: 09/29/2017] [Indexed: 11/17/2022]
Abstract
BACKGROUND Abdominal adhesions are one of the most common complications after abdominal surgery, and fibrin is suspected to be a crucial component. The aim of the current study was an in vivo evaluation of a new recombinant fibrinogenase (AK03) in two animal models. METHODS Sixty-four rats were randomly divided into four groups (sodium chloride [NaCl], icodextrin, AK03 low dose, and AK03 high dose) and evaluated at two time endpoints. Adhesion model comprised both a visceral defect (terminal ileum) and parietal defect. Test (AK03) and control substances (NaCl and icodextrin) were administered intraperitoneally after setting the intraabdominal defects. A second dose was administered 24 h after surgery. Plasma fibrinogen values were taken at baseline and after 7 and 21 d, respectively. Rats were sacrificed after 7 or 21 d for macroscopic (Diamond score) and immunohistochemical investigations. RESULTS After 7 and 21 d, the Diamond score of postsurgical adhesions were significantly lower in both AK03-treated groups compared with NaCl control group (P = 0.02). There were no unspecific systemic side effects in both treatment groups and no decrease in plasma fibrinogen concentration. In none of the four groups was there any evidence for impaired wound repair. Microscopically in the area of the parietal defect, we saw less cluster of differentiation 3+ T-lymphocytes and cluster of differentiation 68+ macrophages in both groups receiving AK03 compared with the NaCl and icodextrin control groups. CONCLUSIONS The results of this study indicate that the new recombinant fibrinogenase AK03 effectively prevents peritoneal adhesions without causing side effects, notably systemic fibrinogen depletion, bleeding, or impaired wound repair. Due to these results, future clinical studies may be promising.
Collapse
|
21
|
MRI Evaluation of an Elastic TPU Mesh under Pneumoperitoneum in IPOM Position in a Porcine Model. J INVEST SURG 2017; 31:185-191. [PMID: 28594257 DOI: 10.1080/08941939.2017.1301599] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
BACKGROUND The frequency of laparoscopic approaches increased in hernia surgery over the past years. After mesh placement in IPOM position, the real extent of the meshes configurational changes after termination of pneumoperitoneum is still largely unknown. To prevent a later mesh folding it might be useful to place the mesh while it is kept under tension. Conventionally used meshes may lose their Effective Porosity under these conditions due to poor elastic properties. The aim of this study was to evaluate a newly developed elastic thermoplastic polyurethane (TPU) containing mesh that retains its Effective Porosity under mechanical strain in IPOM position in a porcine model. It was visualized under pneumoperitoneum using MRI in comparison to polyvinylidenefluoride (PVDF) meshes with similar structure. METHODS In each of ten minipigs, a mesh (TPU containing or native PVDF, 10 × 20 cm) was randomly placed in IPOM position at the center of the abdominal wall. After 8 weeks, six pigs underwent MRI evaluation with and without pneumoperitoneum to assess the visibility and elasticity of the mesh. Finally, pigs were euthanized and abdominal walls were explanted for histological and immunohistochemical assessment. The degree of adhesion formation was documented. RESULTS Laparoscopic implantation of elastic TPU meshes in IPOM position was feasible and safe in a minipig model. Mesh position could be precisely visualized and assessed with and without pneumoperitoneum using MRI after 8 weeks. Elastic TPU meshes showed a significantly higher surface increase under pneumoperitoneum in comparison to PVDF. Immunohistochemically, the amount of CD45-positive cells was significantly lower and the Collagen I/III ratio was significantly higher in TPU meshes after 8 weeks. There were no differences regarding adhesion formation between study groups. CONCLUSIONS The TPU mesh preserves its elastic properties in IPOM position in a porcine model after 8 weeks. Immunohistochemistry indicates superior biocompatibility regarding CD45-positive cells and Collagen I/III ratio in comparison to PVDF meshes with a similar structure.
Collapse
|
22
|
Registry of implants for the reconstruction of pelvic floor in males and females: A feasibility case series. Int J Surg 2017; 42:27-33. [DOI: 10.1016/j.ijsu.2017.04.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 04/10/2017] [Accepted: 04/13/2017] [Indexed: 11/25/2022]
|
23
|
Development of an online platform for registration and outcome measurement of urogynecological implants according to IDEAL-system. Int J Surg 2016. [DOI: 10.1016/j.ijsu.2016.11.048] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
24
|
In vivo imaging of antioxidant response element activity during liver regeneration after partial hepatectomy. J Surg Res 2016; 206:525-535. [DOI: 10.1016/j.jss.2016.08.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 07/03/2016] [Accepted: 08/02/2016] [Indexed: 02/07/2023]
|
25
|
Mesh implants: An overview of crucial mesh parameters. World J Gastrointest Surg 2015; 7:226-236. [PMID: 26523210 PMCID: PMC4621472 DOI: 10.4240/wjgs.v7.i10.226] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2015] [Revised: 07/17/2015] [Accepted: 09/28/2015] [Indexed: 02/06/2023] Open
Abstract
Hernia repair is one of the most frequently performed surgical interventions that use mesh implants. This article evaluates crucial mesh parameters to facilitate selection of the most appropriate mesh implant, considering raw materials, mesh composition, structure parameters and mechanical parameters. A literature review was performed using the PubMed database. The most important mesh parameters in the selection of a mesh implant are the raw material, structural parameters and mechanical parameters, which should match the physiological conditions. The structural parameters, especially the porosity, are the most important predictors of the biocompatibility performance of synthetic meshes. Meshes with large pores exhibit less inflammatory infiltrate, connective tissue and scar bridging, which allows increased soft tissue ingrowth. The raw material and combination of raw materials of the used mesh, including potential coatings and textile design, strongly impact the inflammatory reaction to the mesh. Synthetic meshes made from innovative polymers combined with surface coating have been demonstrated to exhibit advantageous behavior in specialized fields. Monofilament, large-pore synthetic meshes exhibit advantages. The value of mesh classification based on mesh weight seems to be overestimated. Mechanical properties of meshes, such as anisotropy/isotropy, elasticity and tensile strength, are crucial parameters for predicting mesh performance after implantation.
Collapse
|
26
|
Biocompatibility and biomechanical analysis of elastic
TPU
threads as new suture material. J Biomed Mater Res B Appl Biomater 2015; 105:99-106. [DOI: 10.1002/jbm.b.33531] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2015] [Revised: 08/17/2015] [Accepted: 09/12/2015] [Indexed: 11/12/2022]
|
27
|
Analysis of adhesion formation of a new elastic thermoplastic polyurethane (TPU) mesh in comparison to polypropylene (PP) meshes in IPOM position. J Mech Behav Biomed Mater 2015; 53:366-372. [PMID: 26406584 DOI: 10.1016/j.jmbbm.2015.08.036] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 08/28/2015] [Accepted: 08/30/2015] [Indexed: 11/26/2022]
Abstract
BACKGROUND Postsurgical adhesions severely affect the patients' quality of life causing various complications like bowel obstruction or chronic pain. Especially the implantation of alloplastic prostheses in IPOM position for hernia repair carries a high risk of adhesion formation due to the close contact between mesh and viscera. The extent of adhesions mainly depends on the type and textile characteristics of the implanted mesh. The aim of this study was to examine the degree of adhesion formation of a newly developed, elastic thermoplastic polyurethane (TPU) mesh in comparison to polypropylene (PP) meshes in IPOM position in a rabbit model. METHODS Sixteen female chinchilla rabbits were laparoscopically operated. Two different meshes were placed to the left and the right lower abdominal wall in IPOM position in each rabbit. After 7 or 21 days, midline laparotomy was performed, the degree of adhesion formation was examined by the Diamond score and mesh elongation was measured under a force of 3N. Finally, the abdominal walls were explanted for immunohistochemical and histopathological investigations. RESULTS TPU meshes showed significantly lower Diamond scores than PP meshes. After explantation, mesh elongation of the TPU mesh was significantly larger than expansion of PP under a force of 3N. Thus, the TPU mesh preserved its elastic properties after 7 and 21 days. The amount of CD68 positive, Ki67 positive and apoptotic cells within the granuloma around the fibers did not show significant differences between the study groups. CONCLUSIONS The newly developed TPU mesh seems to reduce peritoneal adhesion formation in IPOM position in a rabbit model compared to PP meshes after 7 and 21 days. Immunohistochemistry did not reveal differences in biocompatibility of the two meshes used.
Collapse
|
28
|
Abstract
Pelvic organ prolapse is a common gynaecological problem. Surgical techniques to repair prolapse have been constantly evolving to reduce the recurrence of prolapse and need for reoperation. Grafts made of synthetic and biological materials became popular in the last decade as they were intended to provide extra support to native tissue repairs. However, serious complications related to use of synthetic meshes have been reported and there is increasing medico-legal concern about mesh use in prolapse surgery. Some mesh products already have been withdrawn from the market and the FDA has introduced stricter surveillance of new and existing products. Large randomized studies comparing mesh with non-mesh procedures are lacking which creates uncertainty for the surgeon and their patients.The small cohorts of the RCTs available with short follow-up periods just allow the conclusion that the mesh repair can be helpful in the short to medium term but unfortunately are not able to prove safety for all patients. In particular, current clinical reports cannot define for which indication what material may be superior compared to non-mesh repair.Quality control through long-term individual and national mesh registries is needed to keep a record of all surgeons using mesh and all devices being used, monitoring their effectiveness and safety data. Meshes with better biocompatibility designed specifically for use in vaginal surgery may provide superior clinical results, where the reduction of complications may allow a wider range of indications.
Collapse
|
29
|
Polyvinylidene Fluoride as a Suture Material: Evaluation of Comet Tail-Like Infiltrate and Foreign Body Granuloma. Eur Surg Res 2015; 55:1-11. [DOI: 10.1159/000371797] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Accepted: 12/22/2014] [Indexed: 11/19/2022]
Abstract
Background: Biocompatibility and tissue integration of a surgical suture are decisive factors for wound healing and therefore for the success of sutures. The optimal suture material is still under discussion. Polyvinylidene fluoride (PVDF) is described to have superior properties of biocompatibility and is therefore frequently used as a mesh component. Only little information is available about its use as a suture material. The aim of this study was to evaluate the biocompatibility of PVDF as a suture material in comparison to 5 different established sutures in a rat model. Methods: In 30 male rats, a monofilamental PVDF suture (Resopren®) and 5 established control suture materials [polyester (Miralene®), polytetrafluoroethylene (Gore®), poliglecaprone (Monocryl®), polydioxanone (Monoplus®), polyglactin 910 (Vicryl®), USP size 3-0] were placed in the subcutaneous layer of the abdominal wall without knot or tension. After 3, 7 or 21 days, the abdominal walls were explanted for histopathological and immunohistochemical investigation with special regard to the size and quality of foreign body granuloma and the length of the comet tail-like infiltrate (CTI). Results: The PVDF sutures showed the smallest size of foreign body granuloma (60 ± 14 µm) and the smallest CTI length (343 ± 60 µm) of all polymers after 21 days. Only PVDF (Resopren) and polydioxanone (Monoplus) showed a significant collagen I/III ratio increase between days 3 and 21 (p = 0.009 and p = 0.016). The quality of foreign body reaction regarding inflammation, proliferation and fibrotic remodeling was similar between all suture materials. Conclusions: Our data indicate that monofilamental PVDF sutures show a favorable foreign body reaction with small granuloma sizes and CTI length in comparison to established sutures. Its use as a suture material in general surgery could therefore be extended in the future. To reinforce these findings, further clinical studies need to be conducted.
Collapse
|
30
|
Elastic mesh with thermoplastic polyurethane filaments preserves effective porosity of textile implants. J Biomed Mater Res A 2015; 103:2654-60. [DOI: 10.1002/jbm.a.35411] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 12/10/2014] [Accepted: 01/13/2015] [Indexed: 11/06/2022]
|
31
|
Update of guidelines on laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia (International Endohernia Society). Surg Endosc 2014; 29:289-321. [PMID: 25398194 PMCID: PMC4293469 DOI: 10.1007/s00464-014-3917-8] [Citation(s) in RCA: 179] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Accepted: 09/19/2014] [Indexed: 12/13/2022]
|
32
|
Gut-liver axis improves with meloxicam treatment after cirrhotic liver resection. World J Gastroenterol 2014; 20:14841-14854. [PMID: 25356044 PMCID: PMC4209547 DOI: 10.3748/wjg.v20.i40.14841] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2014] [Revised: 06/07/2014] [Accepted: 06/26/2014] [Indexed: 02/07/2023] Open
Abstract
AIM: To investigate the effect of meloxicam on the gut-liver axis after cirrhotic liver resection.
METHODS: Forty-four male Wistar rats were assigned to three groups: (1) control group (CG); (2) bile duct ligation with meloxicam treatment (BDL + M); and (3) bile duct ligation without meloxicam treatment (BDL). Secondary biliary liver cirrhosis was induced via ligature of the bile duct in the BDL + M and BDL groups. After 2 wk, the animals underwent a 50% hepatectomy. In the BDL + M group 15 min prior to the hepatectomy, one single dose of meloxicam was administered. Parameters measured included: microcirculation of the liver and small bowel; portal venous flow (PVF); gastrointestinal (GI) transit; alanine aminotransferase (ALT); malondialdehyde; interleukin 6 (IL-6), transforming growth factor beta 1 (TGF-β1) and hypoxia-inducible factor 1 alpha (HIF-1α) levels; mRNA expression of cyclooxigenase-2 (COX-2), IL-6 and TGF-β1; liver and small bowel histology; immunohistochemical evaluation of hepatocyte and enterocyte proliferation with Ki-67 and COX-2 liver expression.
RESULTS: Proliferative activity of hepatocytes after liver resection, liver flow and PVF were significantly higher in CG vs BDL + M and CG vs BDL group (P < 0.05), whereas one single dose of meloxicam ameliorated liver flow and proliferative activity of hepatocytes in BDL + M vs BDL group. COX-2 liver expression at 24 h observation time (OT), IL-6 concentration and mRNA IL-6 expression in the liver especially at 3 h OT, were significantly higher in BDL group when compared with the BDL + M and CG groups (P < 0.01, P < 0.001, P < 0.01, respectively). Liver and small bowel histology, according to a semi quantitative scoring system, showed better integrity in BDL + M and CG as compared to BDL group. ALT release and HIF-1α levels at 1 h OT were significantly higher in BDL + M compared to CG and BDL group (P < 0.001 and P < 0.01, respectively). Moreover, ALT release levels at 3 and 24 h OT were significantly higher in BDL group compared to CG, P < 0.01. GI transit, enterocyte proliferative activity and number of goblet cells were in favor of meloxicam treatment vs BDL group (P < 0.05, P < 0.001, P < 0.01, respectively). Additionally, villus length were higher in BDL + M as compared to BDL group.
CONCLUSION: One single dose of meloxicam administered after cirrhotic liver resection was able to cause better function and integrity of the remaining liver and small bowel.
Collapse
|
33
|
Gentamicin for prevention of intraoperative mesh contamination: demonstration of high bactericide effect (in vitro) and low systemic bioavailability (in vivo). Hernia 2014; 18:691-700. [PMID: 25112382 DOI: 10.1007/s10029-014-1293-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Accepted: 07/28/2014] [Indexed: 12/28/2022]
Abstract
INTRODUCTION Mesh infection is a severe complication after incisional hernia repair and occurs in 1-3 % of all open mesh implantations. For this reason, topical antimicrobial agent applied directly to the mesh is often used procedure. So far, however, this procedure lacks a scientific basis. MATERIALS AND METHODS Two different meshes (Parietex™, Covidien; Ultrapro™, Ethicon Johnson & Johnson) were incubated with increasing amounts of three different Staphylococcus aureus strains (ATCC 25923; Mu50; ST239) with or without gentamicin and growth ability were determined in vitro. To further address the question of the systemic impact of topic gentamicin, serum levels were analyzed 6 and 24 h after implantation of gentamicin-impregnated multifilament meshes in 19 patients. RESULTS None of the gentamicin-impregnated meshes showed any bacterial growth in vitro. This effect was independent of the mesh type for all the tested S. aureus strains. In the clinical setting, serum gentamicin levels 6 h after implantation of the gentamicin-impregnated meshes were below the through-level (range 0.4-2.9 mg/l, mean 1.2 ± 0.7 mg/l). After 24 h the gentamicin serum levels in all patients had declined 90-65 % of the 6 h values. CONCLUSION Local application of gentamicin to meshes can completely prevent the growth of even gentamicin-resistant S. aureus strains in vitro. The systemic relevance of gentamicin in the clinical controls showed to be very low, without reaching therapeutic concentrations.
Collapse
|
34
|
Parastomal hernia repair with a 3-D mesh device and additional flat mesh repair of the abdominal wall. Hernia 2014; 18:653-61. [PMID: 25112385 DOI: 10.1007/s10029-014-1302-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2013] [Accepted: 07/28/2014] [Indexed: 01/09/2023]
Abstract
PURPOSE Parastomal hernias (PSHs) have been a major clinical problem. The aim of this study was to evaluate a new method of PSH repair in combination with an additional flat mesh reinforcement of the abdominal wall. METHODS In a pilot case series, seven patients suffering from complex PSHs (≥5 cm diameter and/or recurrence) underwent surgery and were treated by intraperitoneal onlay technique (IPOM) with a synthetic 3-D funnel-shaped mesh implant. The demographics, perioperative, and follow-up data are presented in this report. RESULTS The surgical strategy varied between purely laparoscopic (n = 1), laparoscopically assisted (hybrid n = 3), or open techniques (n = 3) using original or suture-reconstructed mesh devices. The funnel mesh implantations in IPOM technique were combined with attached flat meshes in the appropriate position of the abdominal wall. No procedure-related complications occurred. The mean length of hospital stay was 12 days and the mean operating time was 171 min. No recurrence of PSH or incisional hernias was observed during a mean follow-up period of 12.3 months (range from 7 to 22). CONCLUSION The use of a 3-D mesh implant has so far shown to be a promising option in the treatment of primary and recurrent PSHs. Its use proved to be reasonable in both laparoscopic and open IPOM technique. PSHs were preferably repaired using the original, unmodified implant, but when we also found it safe to incise, place and then suture the mesh around the pre-existing ostomy.
Collapse
|
35
|
Laparotomy closure using an elastic suture: A promising approach. J Biomed Mater Res B Appl Biomater 2014; 103:417-23. [DOI: 10.1002/jbm.b.33222] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Revised: 04/25/2014] [Accepted: 05/17/2014] [Indexed: 11/11/2022]
|
36
|
Collaborative network of predictive markers complicates formation of prognostic groups in patients with advanced lung cancer. Anticancer Res 2014; 34:2745-2754. [PMID: 24922635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
BACKGROUND Evaluation of cancer therapies is mainly based on prolonging remission status and effect of survival. Various serological, clinical or histological markers are used to estimate the patient's prognosis, and to tailor specific therapies for patients with poor prognosis. However, it is still a challenge to combine all this information into a comprehensive risk prediction. PATIENTS AND METHODS In 58 patients with advanced non small cell lung cancer we recorded 38 parameters (15 from clinic, 10 from histology, 13 from serology) to analyze their impact on survival. We both used univariate as well as multivariate approaches and decision tree analysis. RESULTS Univariate analysis showed that ECOG status, stage, and the presence of cerebral or bone metastasis had a significant impact on survival, as well as the serum markers CA15-3, TPA, Cyfra. In a multivariate approach only ECOG and stage had a significant impact on survival. Considering correlation coefficients of >0.3 as an indicator of a functional relationship, we found several relations among the clinical (9), histological (8) or the serological parameters (13). Survival was related to 9 parameters by significant direct and cross-relation coefficients. The use of already few variables with its different possible options led to many different patterns in the cohort, almost all being specific for individual patients, and thereby underlining their heterogeneity. Decision tree analysis revealed that by including either stage and kind of therapy or stage and expression of YB-1 allows to identify sub-groups with distinct prognosis. CONCLUSION Clinical, serological and histological markers, all provide prognostic information. Because they are all linked in a collaborative network, the formation of homogenous prognostic groups by use of single markers is limited. Alternative statistical approaches with focus on decision trees may allow use of various information to assess individual patients into distinct risk groups.
Collapse
MESH Headings
- Biomarkers, Tumor/metabolism
- Bone Neoplasms/metabolism
- Bone Neoplasms/mortality
- Bone Neoplasms/secondary
- Brain Neoplasms/metabolism
- Brain Neoplasms/mortality
- Brain Neoplasms/secondary
- Carcinoma, Non-Small-Cell Lung/metabolism
- Carcinoma, Non-Small-Cell Lung/mortality
- Carcinoma, Non-Small-Cell Lung/secondary
- Carcinoma, Squamous Cell/metabolism
- Carcinoma, Squamous Cell/mortality
- Carcinoma, Squamous Cell/secondary
- Cohort Studies
- Female
- Follow-Up Studies
- Humans
- Lung Neoplasms/metabolism
- Lung Neoplasms/mortality
- Lung Neoplasms/pathology
- Male
- Middle Aged
- Models, Statistical
- Neoplasm Recurrence, Local/metabolism
- Neoplasm Recurrence, Local/mortality
- Neoplasm Recurrence, Local/pathology
- Neoplasm Staging
- Predictive Value of Tests
- Survival Rate
Collapse
|
37
|
Role of preferential cyclooxygenase-2 inhibition by meloxicam in ischemia/reperfusion injury of the rat liver. Eur Surg Res 2014; 53:11-24. [PMID: 24854565 DOI: 10.1159/000362411] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Ischemia/reperfusion injury (IRI) is one of the major clinical problems in liver and transplant surgery. Livers subjected to warm ischemia in vivo often show a severe dysfunction and the release of numerous inflammatory cytokines and arachidonic acid metabolites. Cyclooxygenase (COX)-2 is the inducible isoform of an intracellular enzyme that converts arachidonic acid into prostaglandins. The aim of the study was to evaluate the effect of COX-2 inhibition and the role of Kupffer cells in IRI of the liver. METHODS Male Wistar rats [250- 280 g body weight (BW)] were anesthetized and subjected to 30-min warm ischemia of the liver (Pringle's maneuver) and 60-min reperfusion after median laparotomy. The I/R group received no additional treatment. In the COX-2 inhibitor (COX-2I) group, the animals received 1 mg/kg BW meloxicam prior to operation. Gadolinium chloride (GdCl3) (10 mg/kg BW) was given 24 h prior to operation in the GdCl3 and GdCl3 + COX-2I groups for the selective depletion of Kupffer cells. The GdCl3 + COX-2I group received both GdCl3 and meloxicam treatment prior to operation. Blood and liver samples were obtained at the end of the experiments for further investigations. RESULTS After 30 min of warm ischemia in vivo, severe hepatocellular damage was observed in the I/R group. These impairments could be significantly prevented by the selective COX-2 inhibition and the depletion of Kupffer cells. Alanine aminotransferase was significantly reduced upon meloxicam and GdCl3 treatment compared to the I/R group: I/R, 3,240 ± 1,262 U/l versus COX-2I, 973 ± 649 U/l, p < 0.001; I/R versus GdCl3, 1,611 ± 600 U/l, p < 0.05, and I/R versus GdCl3 + COX-2I, 1,511 ± 575 U/l, p < 0.01. Plasma levels of tumor necrosis factor alpha (TNF-α) were significantly reduced in the COX-2I treatment group compared to I/R (3.5 ± 1.5 vs. 16.3 ± 11.7 pg/ml, respectively; p < 0.05). Similarly, the amount of TxB2, a marker for COX-2 metabolism, was significantly reduced in the meloxicam treatment groups compared to the I/R group: I/R, 22,500 ± 5,210 pg/ml versus COX-2I, 1,822 ± 938 pg/ml, p < 0.001, and I/R versus GdCl3 + COX-2I, 1,530 ± 907 pg/ml, p < 0.001. All values are given as mean ± SD (n = 6). CONCLUSION These results suggest that the inhibition of COX-2 suppressed the initiation of an inflammatory cascade by attenuating the release of TNF-α, which is an initiator of the inflammatory reaction in hepatic IRI. Therefore, we conclude that preferential inhibition of COX-2 is a possible therapeutic approach against warm IRI of the liver.
Collapse
|
38
|
MRT-Evaluation des Therapieerfolgs von Leistenhernien in Patienten mit eisenhaltigen Netzimplantaten. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1372827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
39
|
In vivo characterisation of the inflammatory reaction following mesh implantation in transgenic mice models. Langenbecks Arch Surg 2014; 399:579-88. [DOI: 10.1007/s00423-014-1192-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2013] [Accepted: 03/30/2014] [Indexed: 10/25/2022]
|
40
|
Biomechanical analyses of prosthetic mesh repair in a hiatal hernia model. J Biomed Mater Res B Appl Biomater 2014; 102:1485-95. [PMID: 24599834 DOI: 10.1002/jbm.b.33128] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2013] [Revised: 01/16/2014] [Accepted: 02/18/2014] [Indexed: 01/05/2023]
Abstract
Recurrence rate of hiatal hernia can be reduced with prosthetic mesh repair; however, type and shape of the mesh are still a matter of controversy. The purpose of this study was to investigate the biomechanical properties of four conventional meshes: pure polypropylene mesh (PP-P), polypropylene/poliglecaprone mesh (PP-U), polyvinylidenefluoride/polypropylene mesh (PVDF-I), and pure polyvinylidenefluoride mesh (PVDF-S). Meshes were tested either in warp direction (parallel to production direction) or perpendicular to the warp direction. A Zwick testing machine was used to measure elasticity and effective porosity of the textile probes. Stretching of the meshes in warp direction required forces that were up to 85-fold higher than the same elongation in perpendicular direction. Stretch stress led to loss of effective porosity in most meshes, except for PVDF-S. Biomechanical impact of the mesh was additionally evaluated in a hiatal hernia model. The different meshes were used either as rectangular patches or as circular meshes. Circular meshes led to a significant reinforcement of the hiatus, largely unaffected by the orientation of the warp fibers. In contrast, rectangular meshes provided a significant reinforcement only when warp fibers ran perpendicular to the crura. Anisotropic elasticity of prosthetic meshes should therefore be considered in hiatal closure with rectangular patches.
Collapse
|
41
|
Abstract
Parastomal herniation is a frequent complication when an artificial anus is constructed. As a tunnel through the abdominal wall is nonphysiological, there is an inherent trend to enlargement of the aperture with any artificial stoma. However, none of the technical modifications tried has proved reliable in reducing the incidence of parastomal herniation. The only clear-cut indications for repair are ileus and incarceration or serious problems with the colostomy bags. There are three basic methods of repair: fascial closure, stoma relocation and augmentation of the abdominal wall by nonabsorbable meshes, and any of the three can be combined in many ways. The first two techniques each have a recurrence rate of 40%-80%, and neither can therefore any longer be recommended for use in isolation. Only with the last technique of abdominal wall reinforcement it is possible to achieve a recurrence rate of under 20%. The best type of mesh and the optimal implantation technique are still under discussion.
Collapse
|
42
|
First in vivo visualization of MRI-visible IPOM in a rabbit model. J Biomed Mater Res B Appl Biomater 2014; 102:1165-9. [DOI: 10.1002/jbm.b.33098] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2013] [Revised: 11/10/2013] [Accepted: 12/17/2013] [Indexed: 11/07/2022]
|
43
|
Demands and properties of alloplastic implants for the treatment of stress urinary incontinence. Expert Rev Med Devices 2014; 4:349-59. [PMID: 17488229 DOI: 10.1586/17434440.4.3.349] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Surgical treatment of stress urinary incontinence changed dramatically with the introduction of the tension-free vaginal tape. Owing to its high efficacy and minimal patient discomfort this new minimally invasive procedure quickly obtained widespread acceptance and superseded the abdominal colposuspension as the gold standard. In the course of success of the original method a number of tension-free vaginal tapes flooded the market, varying in approach and material. These variations may strongly influence the safety, efficacy and long-term results of tension-free vaginal tape and its major modification, the transobturator technique. Therefore, it is the aim of this review to closely illuminate available materials and complications associated with this procedure. An extensive Medline search of the published literature up until 2006 on the subject of stress urinary incontinence was carried out. All sources identified were reviewed with particular attention to the method applied, the properties of the mesh materials and clinical complications. Apart from several technical variations, there are marked differences between the different vaginal sling materials, ranging from absorbable collagens over polypropylene to allografts. Although performed globally in substantial and increasing numbers, minimally invasive techniques for the surgical treatment of stress urinary incontinence are lacking sufficient safety data.
Collapse
|
44
|
Bias-Variation Dilemma Challenges Clinical Trials: Inherent Limitations of Randomized Controlled Trials and Meta-Analyses Comparing Hernia Therapies. ACTA ACUST UNITED AC 2014. [DOI: 10.4236/ijcm.2014.513105] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
45
|
Influence of 4% icodextrin solution on peritoneal tissue response and adhesion formation. BMC Surg 2013; 13:34. [PMID: 24020840 PMCID: PMC3846168 DOI: 10.1186/1471-2482-13-34] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Accepted: 09/06/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Postoperative peritoneal adhesion formation following abdominal surgery remains a relevant surgical problem. The application of soluble physico-chemical barriers like 4% icodextrin is one approach to protect the peritoneal surface from getting linked to adhesive scar. The aim of this study was to investigate the influence of 4% icodextrin on peritoneal tissue response both of visceral and parietal peritoneum, adhesion formation and wound healing. METHODS 40 rats were divided into two groups. After creation of an intraabdominal defect, either 4% icodextrin (Adept®) or sodium chloride was applied. Animals were sacrificed after 7 and 21 days. Adhesions were scored by an adhesion score. Furthermore, immunohistochemical investigations were conducted to determine the discrete influence of icodextrin on the parietal and visceral peritoneal tissue responses (CD68+ macrophages, CD3+ T-lymphocytes, vimentin for mesenchymal cells, HBME-1 for mesothelial cells, and as components of wound healing COX-2, C-myc, catenin). RESULTS Postoperative peritoneal adhesions were predominantly present in the sodium chloride group as compared to the icodextrin group (14/19 (74%) vs. 9/19 (47%); p = 0.048). The adhesion score however did not reveal any significant differences, (p = 0.614). Furthermore, the expression of vimentin in both the parietal and visceral peritoneum after 21 days was significantly lower in the icodextrin group than in the sodium chloride group (p = 0.038 and p = 0.028, respectively). No significant differences were observed for macrophages, lymphocytes, reperitonealisation or the expression of COX-2, C-myc or Catenin. CONCLUSIONS The intraperitoneal application of 4% icodextrin reduces adhesion formation in comparison to sodium chloride. 4% icodextrin solution reduces the inflammatory and mesenchymal infiltrate in the wounded area, thus improving the ratio of mesothel cells to mesenchymal infiltrate. As demonstrated, icodextrin is able to ameliorate the local tissue response. Further experimental studies would be done to elaborate the impact on the early response of the adaptive immune system, which may then trigger the subsequent wound healing and tissue repair.
Collapse
|
46
|
Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates. J Biomed Mater Res A 2013; 102:1079-84. [PMID: 23625516 DOI: 10.1002/jbm.a.34767] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Accepted: 04/17/2013] [Indexed: 11/06/2022]
Abstract
Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift(®) and Prolift + M(®), developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4(®), which was designed for pelvic floor repair to withstand mechanical strain. Prolift(®) at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M(®) revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4(®) preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift(®) and Prolift + M(®) can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.
Collapse
|
47
|
Retrieval study at 623 human mesh explants made of polypropylene - impact of mesh class and indication for mesh removal on tissue reaction. J Biomed Mater Res B Appl Biomater 2013:n/a-n/a. [PMID: 23686765 DOI: 10.1002/jbmb.32958] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Revised: 03/04/2013] [Accepted: 03/27/2013] [Indexed: 12/12/2022]
Abstract
Textile meshes frequently are implanted in the abdominal wall to reinforce a hernia repair. However, revisions for mesh associated complications confirm that these devices are not completely free of risk. Explanted devices offer an opportunity to define the impact of mesh structure on tissue response. This retrieval study analyses the tissue reaction to 623 polypropylene mesh samples (170 class 1 with large pores, and 453 class 2 with small pores) explanted for pain, infection, or recurrence. Histopathological assessment included morphometry of inflammatory infiltrate (IF) and connective tissue (CT), and of collagen 1/3 ratio. Half of the meshes were removed after more than 23 month. Despite large inter-individual differences removal for infection showed more IF than for pain or recurrence with significant correlation of IF with CT. Class 1 meshes with large pores showed less IF, CT, fistula formation, calcification, and bridging than class 2 meshes with small pores. Meshes removed for recurrence showed a lowered collagen 1/3 ratio in 70%. Large pore class 1 meshes showed an improved tissue response and may be considered as favorable to prevent inflammatory side effects. The presence of lowered collagen 1/3 ratio in most of the samples with recurrences stresses the relevance of an intact healing process. Late manifestation of complications demands long-lasting follow-up. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
Collapse
|
48
|
Abstract
Currently, more than 200 different textile constructions, so-called 'meshes', are available for use world-wide in the more than 20 million operations performed annually for the reinforcement of tissues. As any reintervention at the mesh-tissue compound is a surgical challenge, sometimes resulting in almost untreatable defects, huge efforts are being made to improve the biological and functional performance of the meshes. Based on numerous experimental and clinical studies in the past 20 years, our understanding of them has improved markedly. This includes the biomechanical aspects and the histopathological evaluation of the recipient tissue. Sufficiently large pores as well as structural stability in case of mechanical strain have been identified to be crucial to reduce excessive inflammation and fibrosis. Furthermore, large pores prevent bridging of the foreign body reaction through the pore and thereby help to reduce clinical adverse events as erosion, shrinkage or pain. However, with regard to the many different indications for meshes, there will never be one single ideal mesh for all purposes. To achieve an optimal performance, every construction should be designed according to the specific functional requirements, charging the surgeon to identify the best mesh for his purpose.
Collapse
|
49
|
Aldosterone Modulates Endothelial Permeability and Endothelial Nitric Oxide Synthase Activity by Rearrangement of the Actin Cytoskeleton. Hypertension 2013; 61:501-8. [DOI: 10.1161/hypertensionaha.111.196832] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
50
|
Abstract 515: Aldosterone Modulates Endothelial Paracellular Permeability by Opening Intercellular Junctions. Hypertension 2012. [DOI: 10.1161/hyp.60.suppl_1.a515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Aldosterone (Ald) is involved in vascular remodeling and inflammation; however, the mechanisms are imperfectly defined. We hypothesized that Ald alters endothelial integrity and modifies paracellular permeability. Human umbilical vein endothelial cells (HUVEC) were exposed to Ald (10
-9
mol/L) and alterations in paracellular permeability, assembly of tight and adherens junctions, and activation of intracellular signaling pathways were determined. Ald increased endothelial paracellular permeability for molecules up to 70 kDa within 60 min. A transient loss of cortical actin with formation of actin stress fibers, and disruption of continuous adherens and tight junction strands, accompanied the changes. Mineralocorticoid receptor (MR) blockade, inhibition of RhoA or disruption of extracellular regulated protein kinase (ERK) 1/2 signaling pathways attenuated the Ald-related effects. Moreover, the observed changes of the actin cytoskeleton and intercellular junction architecture were accompanied by a rapid dephosphorylation of protein kinase B (AKT) as well as deactivation of endothelial NO synthase (eNOS). Ex vivo tracer flux experiments with Evans Blue (EB)-conjugated albumin demonstrated concordant response to Ald in freshly isolated umbilical arteries. In summary, Ald leads to increased permeability of endothelial monolayer or isolated arteries. These alterations are associated with a temporal opening of Intercellular junctions and diminished eNOS activity, and depend on activation of the RhoA/ERK pathway. We conclude that these mechanisms could contribute to Ald-induced vasculopathy.
Collapse
|