1
|
Improvement in the Chromium(VI)-Diphenylcarbazide Determination Using Cloud Point Microextraction; Speciation of Chromium at Low Levels in Water Samples. Molecules 2023; 29:153. [PMID: 38202735 PMCID: PMC10779736 DOI: 10.3390/molecules29010153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/22/2023] [Accepted: 12/24/2023] [Indexed: 01/12/2024] Open
Abstract
A reliable, rapid, and low-cost procedure for determining very low concentrations of hexavalent chromium (Cr) in water is discussed. The procedure is based in the classical reaction of Cr6+ with diphenylcarbazide. Once this reaction has taken place, sodium dodecylsulfate is added to obtain an ion-pair, and Triton X-114 is incorporated. Next, the heating of the mixture allows two phases that can be separated by centrifugation to be obtained in a cloud point microextraction (CPE) process. The coacervate contains all the Cr6+ originally present in the water sample, so that the measurement by molecular absorption spectrophotometry allows the concentration of the metal to be calculated. No harmful organic solvents are required. The discrimination of hexavalent and trivalent forms is achieved by including an oxidation stage with Ce4+. To take full advantage of the pre-concentration effect inherent to the coacervation process, as well as to minimize reagent consumption and waste generation, a portable mini-spectrophotometer which is compatible with microvolumes of liquid samples is used. The preconcentration factor is 415 and a chromium concentration as low as 0.02 µg L-1 can be detected. The procedure shows a good reproducibility (relative standard deviation close to 3%).
Collapse
|
2
|
Copper Nanoparticles Confined in a Silica Nanochannel Film for the Electrochemical Detection of Nitrate Ions in Water Samples. Molecules 2023; 28:7515. [PMID: 38005239 PMCID: PMC10673492 DOI: 10.3390/molecules28227515] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/05/2023] [Accepted: 11/07/2023] [Indexed: 11/26/2023] Open
Abstract
The nitrate ion (NO3-) is a typical pollutant in environmental samples, posing a threat to the aquatic ecosystem and human health. Therefore, rapid and accurate detection of NO3- is crucial for both the aquatic sciences and government regulations. Here we report the fabrication of an amino-functionalized, vertically ordered mesoporous silica film (NH2-VMSF) confining localized copper nanoparticles (CuNPs) for the electrochemical detection of NO3-. NH2-VMSF-carrying amino groups possess an ordered perpendicular nanochannel structure and ultrasmall nanopores, enabling the confined growth of CuNPs through the electrodeposition method. The resulting CuNPs/NH2-VMSF-modified indium tin oxide (ITO) electrode (CuNPs/NH2-VMSF/ITO) combines the electrocatalytic reduction ability of CuNPs and the electrostatic attraction capacity of NH2-VMSF towards NO3-. Thus, it is a rapid and sensitive electrochemical method for the determination of NO3- with a wide linear detection range of 5.0-1000 μM and a low detection limit of 2.3 μM. Direct electrochemical detection of NO3- in water samples (tap water, lake water, seawater, and rainwater) with acceptable recoveries ranging from 97.8% to 109% was performed, demonstrating that the proposed CuNPs/NH2-VMSF/ITO sensor has excellent reproducibility, regeneration, and anti-interference abilities.
Collapse
|
3
|
Electrochemical Rapid Detection of Methamphetamine from Confiscated Samples Using a Graphene-Based Printed Platform. SENSORS (BASEL, SWITZERLAND) 2023; 23:6193. [PMID: 37448052 DOI: 10.3390/s23136193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 06/29/2023] [Accepted: 07/04/2023] [Indexed: 07/15/2023]
Abstract
Methamphetamine (MAP) is a highly addictive and illegal stimulant drug that has a significant impact on the central nervous system. Its detection in biological and street samples is crucial for various organizations involved in forensic medicine, anti-drug efforts, and clinical diagnosis. In recent years, nanotechnology and nanomaterials have played a significant role in the development of analytical sensors for MAP detection. In this study, a fast, simple, and cost-effective electrochemical sensor is presented that is used for the sensitive detection of MAP in confiscated street samples with a complex matrix. The optimized screen-printed sensor based on a carbon working electrode modified with graphene demonstrated an excellent limit of detection, good sensitivity, and a wide dynamic range (1-500 μM) for the target illicit drug both for standard solutions and real samples (seized samples, tap water, and wastewater samples). It can detect MAP at concentrations as low as 300 nM in real samples. This limit of detection is suitable for the rapid preliminary screening of suspicious samples in customs, ports, airports, and on the street. Furthermore, the sensor exhibits a good recovery rate, indicating its reliability and repeatability. This quality is crucial for ensuring consistent and accurate results during screening processes.
Collapse
|
4
|
Confirmation of presumptive Legionella colonies on culture media according to ISO 11731:2017: Principles, problems and practice. J Appl Microbiol 2023:7163219. [PMID: 37188646 DOI: 10.1093/jambio/lxad100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
AIMS The ISO 11731 norm, published in 2017, describes a method to identify and enumerate Legionella based exclusively on the confirmation of presumptive colonies by subculturing them on BCYE and BCYE-cys agar (BCYE agar without L-cysteine). METHODS AND RESULTS Despite this recommendation, our laboratory has kept confirming all presumptive Legionella colonies by combining the subculture method with the latex agglutination and polymerase chain reaction (PCR) assays. Here, we show that the ISO 11731:2017 method adequately performs in our laboratory according ISO 13843:2017. We compared the performance of the ISO method in detecting Legionella in typical and atypical colonies (n = 7156) from health care facilities (HCFs) water samples to that of our combined protocol and we found a 2.1% false positive rate (FPR), underscoring the importance of combining agglutination test and PCR with subculture to achieve optimal confirmation. Lastly, we estimated the water system disinfection cost for HCFs (n = 7), that due to false positive results, would displayed Legionella values exceeding the threshold of risk acceptance established by the Italian guidelines. CONCLUSIONS Overall, this large-scale study indicates that the ISO 11731:2017 confirmation method is error-prone, leading to significant FPRs and higher costs for HCFs due to remedial actions on their water systems.
Collapse
|
5
|
Molecular Identification of Protozoan Sarcocystis in Different Types of Water Bodies in Lithuania. LIFE (BASEL, SWITZERLAND) 2022; 13:life13010051. [PMID: 36676000 PMCID: PMC9864107 DOI: 10.3390/life13010051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022]
Abstract
Representatives of the genus Sarcocystis are unicellular parasites having a two-host life cycle and infecting mammals, birds, and reptiles. Until now, Sarcocystis spp. have been mainly investigated in definitive and intermediate hosts. Only a few studies have been conducted on the detection of Sarcocystis parasites in water samples. The aim of this research was to examine whether the prevalence of Sarcocystis spp. parasitizing farm animals varies in different types of water bodies. Water samples (n = 150) were collected from the entire territory of Lithuania, dividing water bodies into five groups (lakes, rivers, ponds/canals, swamps, and the inshore zone of the territorial Baltic Sea area). One-liter samples were filtered and subsequently analyzed using nested PCR. At least one of the analyzed Sarcocystis spp. (S. arieticanis, S. bertrami, S. bovifelis, S. capracanis, S. cruzi, S. hirsuta, S. miescheriana, and S. tenella) was determined in all examined samples from water bodies. No significant difference in Sarcocystis spp. prevalence between different types of water sources was detected. Our research proved that selecting appropriate primers is important for the accurate identification of parasites in samples collected from water bodies.
Collapse
|
6
|
Simultaneous Dispersive Liquid-Liquid Microextraction and Determination of Different Polycyclic Aromatic Hydrocarbons in Surface Water. Molecules 2022; 27:molecules27238586. [PMID: 36500677 PMCID: PMC9736002 DOI: 10.3390/molecules27238586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 12/12/2022] Open
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are a class of persistent organic pollutants of water, and their determination at trace levels in the aquatic ecosystems is essential. In this work, an ultrasound-assisted dispersive liquid-liquid microextraction (DLLME) procedure was suggested utilizing a binary dispersive agent for recovery of different molecular weight polycyclic aromatic hydrocarbons (PAHs) from waters. The detection was carried out by gas chromatography-mass spectrometry (GC-MS) as well as high-performance liquid chromatography with fluorescence and diode-array detection (HPLC-FD/PDA). The method was optimized for the extraction of analytes with respect to the mixture composition, ratios of components, ultrasonication time and centrifugation parameters. The analytical schemes for PAHs extraction from water samples using different ratios of extraction and dispersive solvents are reported. The mixture consisting of chloroform and methanol was applied for the extraction of PAHs containing two or three fused aromatic rings; the mixture of chloroform and acetonitrile is suitable for PAHs containing more than four aromatic rings. The mixture of chloroform:acetone + acetonitrile was applied in the universal scheme and allowed for the simultaneous extraction of 20 PAHs with different structures. The developed sample preparation schemes were combined with GC-MS and HPLC-FD/PDA, which allowed us to determine the analytes at low concentrations (from 0.0002 µg/L) with the recoveries exceeding 80% and relative standard deviations of about 8%. The developed methods for the determination of 20 PAHs were applied to the analysis of water samples from the Karasun Lake (Krasnodar), Azov Sea (Temryuk) and Black Sea (Sochi).
Collapse
|
7
|
Sodium-Alginate-Functionalized Silver Nanoparticles for Colorimetric Detection of Dimethoate. BIOSENSORS 2022; 12:1086. [PMID: 36551053 PMCID: PMC9775393 DOI: 10.3390/bios12121086] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/20/2022] [Accepted: 11/23/2022] [Indexed: 06/17/2023]
Abstract
Sodium alginate (SA) was used to functionalize the surfaces of silver nanoparticles (AgNPs) to form SA-AgNPs for sensing dimethoate with a rapid and sensitive visual readout. UV-Vis spectrophotometry, Fourier transform infrared spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and zeta potential measurements were used to characterize SA-AgNPs that were synthesized under the ideal conditions. SA-AgNPs were spherical with an average size of 14.6 nm. The stability of SA-AgNPs was investigated with changes in pH, salinity, and storage time. This colorimetric assay of dimethoate relied on the change in the absorption ratio (A475/A400) of SA-AgNPs, resulting in their aggregation caused by dimethoate, leading to a visual change for SA-AgNPs from yellow to pale yellow. As a result, the absorption ratio (A475/A400) of SA-AgNPs showed good linearity in the range of 0.05 to 2.0 ppm (R2 = 0.9986) with a limit of detection (LOD) of 30 ppb. Adding other pesticides did not significantly change the absorption ratio of SA-AgNPs, indicating its high selectivity as a colorimetric assay. The sensor was successfully used to detect dimethoate in actual water samples.
Collapse
|
8
|
The Ultratrace Determination of Fluoroquinolones in River Water Samples by an Online Solid-Phase Extraction Method Using a Molecularly Imprinted Polymer as a Selective Sorbent. Molecules 2022; 27:molecules27238120. [PMID: 36500214 PMCID: PMC9737498 DOI: 10.3390/molecules27238120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
Fluoroquinolones (FQs) are broad-spectrum antibiotics widely used to treat animal and human infections. The use of FQs in these activities has increased the presence of antibiotics in wastewater and food, triggering antimicrobial resistance, which has severe consequences for human health. The detection of antibiotics residues in water and food samples has attracted much attention. Herein, we report the development of a highly sensitive online solid-phase extraction methodology based on a selective molecularly imprinted polymer (MIP) and fluorescent detection (HPLC-FLD) for the determination of FQs in water at low ng L−1 level concentration. Under the optimal conditions, good linearity was obtained ranging from 0.7 to 666 ng L−1 for 7 FQs, achieving limits of detection (LOD) in the low ng L−1 level and excellent precision. Recoveries ranged between 54 and 118% (RSD < 17%) for all the FQs tested. The method was applied to determining FQs in river water. These results demonstrated that the developed method is highly sensitive and selective.
Collapse
|
9
|
Microwave-Assisted Synthesis of Red Emitting Copper Nanoclusters Using Trypsin as a Ligand for Sensing of Pb 2+ And Hg 2+ Ions in Water and Tobacco Samples. APPLIED SPECTROSCOPY 2022; 76:1234-1245. [PMID: 35477299 DOI: 10.1177/00037028221100544] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In this work, a microwave assisted method was developed for synthesis of red fluorescent copper nanoclusters (NCs) using trypsin as a template (trypsin-Cu). The as-synthesized trypsin-Cu NCs are stable and water soluble, exhibiting fluorescence emission at 657 nm when excited at 490 nm. The as-prepared red-emitting trypsin-Cu NCs were characterized by using several analytical techniques such as ultraviolet-visible (UV-Vis) and fluorescence, fluorescence lifetime, Fourier transform infrared, and X-ray photoelectron spectroscopic techniques. Red-emitting trypsin-Cu NCs acted as a nanosensor for sensing both Pb2+ and Hg2+ ions through fluorescence quenching. Using this approach, good linearities are observed in the range of 0.1-25 and of 0.001-1 μM with the lower limit of detection of 14.63 and 56.81 nM for Pb2+ and Hg2+ ions, respectively. Trypsin-Cu NCs-based fluorescence assay was successfully applied to detect both Hg2+ and Pb2+ ions in water and tobacco samples.
Collapse
|
10
|
SERS-Based Methodology for the Quantification of Ultratrace Graphene Oxide in Water Samples. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:9527-9535. [PMID: 35700386 PMCID: PMC9261266 DOI: 10.1021/acs.est.2c00937] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The extensive use of graphene materials in real-world applications has increased their potential release into the environment. To evaluate their possible health and ecological risks, there is a need for analytical methods that can quantify these materials at very low concentrations in environmental media such as water. In this work, a simple, reproducible, and sensitive method to detect graphene oxide (GO) in water samples using the surface-enhanced Raman spectroscopy (SERS) technique is presented. The Raman signal of graphene is enhanced when deposited on a substrate of gold nanoparticles (AuNPs), thus enabling its determination at low concentrations with no need for any preconcentration step. The practical limit of quantification achieved with the proposed method was 0.1 ng mL-1, which is lower than the predicted concentrations for graphene in effluent water reported to date. The optimized procedure has been successively applied to the determination of ultratraces of GO in water samples.
Collapse
|
11
|
Abstract
This work introduces the concept of a counting-based measurement on paper analytical devices (cPADs) to improve the utilization of numerous reactions. The design of cPADs consists of two layers of paper substrates; the first layer contains a central sample zone combined with a radial surrounded by 12 detection zones that are predeposited with the various reagents, and the second layer acts as a connection channel between the sample zone and each detection zone. The solution can vertically flow from the first to the second layer and then move through the area to each subsequent detection zone. The analyte level can be evaluated by counting the number of detection zones that change color from a blank signal. Furthermore, our cPADs exhibit a capability of implementation for a broad series of reactions. Compared to the dPAD technique, some reactions that are possibly difficult to apply in such devices can be wholly enabled in our devices. The final color reaction on cPADs can apparently occur due to its identity. We applied this technique to the monitoring of carbaryl (CBR) and copper ions (Cu2+) using different reactions, including azo-coupling and complexation, respectively. Accordingly, this indicates an excellent result validated using the more traditional methods. Our cPADs can be applied for rapid screening of both CBR and Cu2+ in water samples with outstanding accuracy and precision using a naked-eye measurement by a relatively unskilled person. We offer a simple platform on PADs for rapid screening, combining high cost-effectiveness within a miniaturized platform designed for use with onsite applications, which is thus suitable for several different reactions.
Collapse
|
12
|
Detection of Cryptosporidium spp. and Giardia spp. in Environmental Water Samples: A Journey into the Past and New Perspectives. Microorganisms 2022; 10:microorganisms10061175. [PMID: 35744692 PMCID: PMC9228427 DOI: 10.3390/microorganisms10061175] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 06/03/2022] [Accepted: 06/04/2022] [Indexed: 01/27/2023] Open
Abstract
Among the major issues linked with producing safe water for consumption is the presence of the parasitic protozoa Cryptosporidium spp. and Giardia spp. Since they are both responsible for gastrointestinal illnesses that can be waterborne, their monitoring is crucial, especially in water sources feeding treatment plants. Although their discovery was made in the early 1900s and even before, it was only in 1999 that the U.S. Environmental Protection Agency (EPA) published a standardized protocol for the detection of these parasites, modified and named today the U.S. EPA 1623.1 Method. It involves the flow-through filtration of a large volume of the water of interest, the elution of the biological material retained on the filter, the purification of the (oo)cysts, and the detection by immunofluorescence of the target parasites. Since the 1990s, several molecular-biology-based techniques were also developed to detect Cryptosporidium and Giardia cells from environmental or clinical samples. The application of U.S. EPA 1623.1 as well as numerous biomolecular methods are reviewed in this article, and their advantages and disadvantages are discussed guiding the readers, such as graduate students, researchers, drinking water managers, epidemiologists, and public health specialists, through the ever-expanding number of techniques available in the literature for the detection of Cryptosporidium spp. and Giardia spp. in water.
Collapse
|
13
|
Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples. SENSORS 2022; 22:s22031151. [PMID: 35161895 PMCID: PMC8838205 DOI: 10.3390/s22031151] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 01/26/2022] [Accepted: 01/30/2022] [Indexed: 02/04/2023]
Abstract
A very simple, as well as sensitive and selective, sensing protocol was developed on a pre-anodized graphite pencil electrode surface coated using poly(thionine) (APGE/PTH). The poly(thionine) coated graphite pencil was then used for simultaneous sensing of 3-nitrophenol (3-NP) and 4-nitrophenol (4-NP). The poly(thionine) coated electrode exhibited an enhanced electrocatalytic property towards nitrophenol (3-NP and 4-NP) reduction. Redox peak potential and current of both nitrophenols were found well resolved and their simultaneous analysis was studied. Under optimized experimental conditions, APGE/PTH showed a long linear concentration range from 20 to 230 nM and 15 nM to 280 nM with a calculated limit of detection (LOD) of 4.5 and 4 nM and a sensitivity of 22.45 µA/nM and 27.12 µA/nM for 3-NP and 4-NP, respectively. Real sample analysis using the prepared sensor was tested with different environmental water samples and the sensors exhibited excellent recovery results in the range from 98.16 to 103.43%. Finally, the sensor exposed an promising selectivity, stability, and reproducibility towards sensing of 3-NP and 4-NP.
Collapse
|
14
|
A Novel Hydrogen Fluoride Assisted-Glass Surface Etching Based Liquid Phase Microextraction for the Determination of 4-n-Nonylphenol in Water by Gas Chromatography-Mass Spectrometry with Matrix Matching Strategy. ANAL SCI 2021; 37:1433-1438. [PMID: 33867401 DOI: 10.2116/analsci.21p013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A novel extraction method named hydrogen fluoride assisted-glass surface etching based liquid phase microextraction (HF-GSE-LPME) was proposed to determine 4-n-nonylphenol at trace levels by gas chromatography-mass spectrometry (GC-MS). After the evaluation of system analytical performance for the HF-GSE-LPME-GC-MS system, limit of detection (LOD) and limit of quantification (LOQ) values were calculated as 7.1 and 23.8 ng/g, respectively. Enhancement in detection power of the method was determined to be 22 fold when LOD values of the GC-MS and HF-GSE-LPME-GC-MS systems were compared with each other. Applicability and accuracy of the established method were checked by performing spiking experiments. A matrix matching calibration strategy was applied to boost the accuracy of quantification in both matrices, and the percent recovery results obtained for bottled drinking water and dam lake water samples were in the range of 98 - 107 and 90 - 117%, respectively.
Collapse
|
15
|
Determination of polyhalogenated carbazoles in waters at low nanogram-per-liter concentrations with solid-phase disk extraction. J Sep Sci 2021; 44:3840-3848. [PMID: 34375032 DOI: 10.1002/jssc.202100493] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 07/21/2021] [Accepted: 08/04/2021] [Indexed: 11/10/2022]
Abstract
Polyhalogenated carbazoles, a class of emerging contaminants with persistence and dioxin-like toxicity, have received increasing attention in recent years. In this study, a simple, rapid, sensitive, and high throughput method based on solid-phase disk extraction and gas chromatography-mass spectrometry was described for the determination of polyhalogenated carbazoles in low nanogram-per-liter range in water samples. The proposed solid-phase disk extraction method was initially optimized, and the optimum experimental conditions found were 1 L water sample (pH 6-9) extracted and enriched by Empore 3-stn octadecyl disk at flow rate of 5 to 50 mL/min and eluted by 5 mL of acetone and 3 × 10 mL methylene dichloride. The linearity of the method ranged from 0.2 to 50 ng/L for carbazole and 11 polyhalogenated carbazoles, with correlation coefficients ranging from 0.9951 to 0.9996. The limits of detection were in the low nanogram per liter level, ranging from 0.018 to 0.12 ng/L. Finally, the optimized method was applied for determining trace levels of carbazole and 11 polyhalogenated carbazoles in tap water and seawater samples with good recovery of 86.6-112.8%. Carbazole and 3-7 polyhalogenated carbazoles were detected, and 3,6-dichlorocarbazole was the predominant congener both in tap water and seawater.
Collapse
|
16
|
One-Pot Hydrothermal Synthesis of Carbon Dots as Fluorescent Probes for the Determination of Mercuric and Hypochlorite Ions. NANOMATERIALS 2021; 11:nano11071831. [PMID: 34361216 PMCID: PMC8308378 DOI: 10.3390/nano11071831] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 07/06/2021] [Accepted: 07/13/2021] [Indexed: 01/09/2023]
Abstract
Nitrogen and sulfur codoped carbon dots (NSCDs) were synthesized via a one-pot hydrothermal method, and citric acid, ethylenediamine, and methyl blue were used as precursors. The obtained NSCDs were spherical with an average size of 1.86 nm. The fluorescence emission spectra of the NSCDs were excitation independent and emitted blue fluorescence at 440 nm with an excitation wavelength at 350 nm. The quantum yield of the NSCDs was calculated to be 68.0%. The NSCDs could be constructed as fluorescent probes for highly selective and sensitive sensing mercuric (Hg2+) and hypochlorite (ClO−) ions. As the addition of Hg2+ or ClO− ions to the NSCDs, the fluorescence intensity was effectively quenched due to dynamic quenching. Under the optimal conditions, the linear response of the fluorescence intensity ranged from 0.7 μM to 15 μM with a detection limit of 0.54 μM and from 0.3 μM to 5.0 μM with a limit of detection of 0.29 μM for Hg2+ and ClO− ions, respectively. Finally, the proposed method was successfully used for quantifying Hg2+ and ClO− ions in spiked tap water samples.
Collapse
|
17
|
Investigation of the presence of Legionella pneumophila in water samples from Erzurum and surrounding provinces in Turkey. ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE : AAEM 2021; 28:255-259. [PMID: 34184507 DOI: 10.26444/aaem/135052] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
INTRODUCTION AND OBJECTIVE Legionnaires' disease, which is a waterborne disease leading to pneumonia that can result in death, is one of the major health issues today. The study aims to carry out a three-year retrospective review of routine Legionella follow-up analyses in various samples taken mostly from hospitals in the province of Erzurum and nearby provinces, and to discover a the frequency of isolation of the agent and serogroups from each kind of media. MATERIAL AND METHODS The study included a total of 2,025 water samples taken from hospitals, hotels, Turkish baths and shopping malls in Erzurum,and 13 nearby cities between 2016 and 2018. Samples were filtered by 0.45 μm-diameter membrane filter paper in the Public Health Laboratory of Erzurum and examined for L. pneumophila using culture method, according to the criteria set out in ISO 11731-2. RESULTS The presence of L. pneumophila was found in 65 of the 2,025 water samples taken in hospitals, and in none of 40 samples taken in hotels, Turkish baths and shopping malls. L. pneumophila serogroup 2-14 was detected in 46 (70.8%) of 65 samples found positive, whereas L. pneumophila serogroup 1 was detected in 18 (27.7%). Furthermore, both the L. pneumophila serogroup 2-14 and L. pneumophila serogroup 1 were detected simultaneously in one example (1.5%). The first three samples indicate that the highest positivity rates were in hot water taps (11.6%), hot water tanks (6.1%) and shower heads (4.8%). CONCLUSIONS The Prevalence rat of L. pneumophila was found to be quite low compared to other studies conducted in the western regions of Turkey. Legionella positivity was found to be higher in the hot water systems of hospitals and related points, compared to the other sample points.
Collapse
|
18
|
New Detection Platform for Screening Bacteria in Liquid Samples. BIOSENSORS 2021; 11:142. [PMID: 34062907 PMCID: PMC8147366 DOI: 10.3390/bios11050142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/21/2021] [Accepted: 04/28/2021] [Indexed: 11/26/2022]
Abstract
The development of sensitive methods for the determination of potential bacterial contamination is of upmost importance for environmental monitoring and food safety. In this study, we present a new method combining a fast pre-enrichment step using a microporous cryogel and a detection and identification step using antimicrobial peptides (AMPs) and labelled antibodies, respectively. The experimental method consists of: (i) the capture of large amounts of bacteria from liquid samples by using a highly porous and functionalized cryogel; (ii) the detection and categorisation of Gram-positive and Gram-negative bacteria by determining their affinities toward a small set of AMPs; and (iii) the identification of the bacterial strain by using labelled detection antibodies. As proof of concept, the assessment of the three steps of the analysis was performed by using Escherichia coli and Bacillus sp. as models for Gram-negative and Gram-positive bacteria, respectively. The use of AMPs with broad specificity combined with labelled antibodies enabled the detection and potential categorization of a large spectrum of unknown or unexpected bacteria.
Collapse
|
19
|
A Novel Fluorescent Probe for Selective Detection of Hydrazine and Its Application in Imaging. BIOSENSORS-BASEL 2021; 11:bios11050130. [PMID: 33922028 PMCID: PMC8143562 DOI: 10.3390/bios11050130] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/15/2021] [Accepted: 04/18/2021] [Indexed: 11/17/2022]
Abstract
In this work, a novel fluorescent probe with first-time-selected thiazepine backbone, TZPzine-1, was developed for selective detection of hydrazine in water samples and living cells. Chosen from our recent anti-cancer agents, TZPzine-1 inferred structurally based advantages of the optical adjustability and the hydrazine-trapping approach. It also showed applicable properties including high sensitivity (LOD = 50 nM), wide linear range (0–15 equiv.), high selectivity (especially from competing species), rapid response (within 20 min), and practical steadiness in various pH (6.0–11.0) and temperature (15–50 °C) conditions. To satisfy the interdisciplinary requirements in environmental toxicology, TZPzine-1 was successfully applied in water samples and living cells. We hope that the information in this work, as well as the concept of monitoring the nitrogen cycle, may be referable for future research on systematic management.
Collapse
|
20
|
Clonal CTX-M-15-Producing Escherichia coli ST-949 Are Present in German Surface Water. Front Microbiol 2021; 12:617349. [PMID: 33912141 PMCID: PMC8072356 DOI: 10.3389/fmicb.2021.617349] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 03/24/2021] [Indexed: 11/13/2022] Open
Abstract
Extended-spectrum beta-lactamase (ESBL)-producing bacterial isolates are emerging within the last years. To understand this emergence, a thorough genome-based analysis of ESBL isolates from different sources (One Health approach) is needed. Among these, analysis of surface water is underrepresented. Therefore, we performed a genome-based analysis of ESBL-producing Escherichia coli isolates from surface water samples. Water samples were collected from eleven different surface water sites (lakes, river). ESBL-producing E. coli were recovered from these samples using filters and chromogenic media. Whole-genome sequencing of ESBL-producing E. coli was performed followed by determination of the multilocus sequence type (ST), ESBL-type, and virulence genes. Phylogenetic analysis was done using single nucleotide analysis. From all water samples taken, nineteen ESBL-producing E. coli were recovered. All of them harbored an ESBL gene. Nine different multilocus STs were determined, among which ST-949 was the ST detected most frequently. Phylogenetic analysis of ST-949 isolates revealed that all those isolates were closely related. In addition, they harbored an identical chromosomal insertion of bla CTX-M-15 , indicating a clonal relationship among these isolates. Genetic comparison with isolates from all over the world revealed that these isolates were closely related to human clinical isolates derived from New Zealand and Sweden. An ESBL-producing E. coli ST-949 clone was detected in German surface waters. Its close relationship to human clinical isolates suggests its ability to colonize or even infect humans. Our findings reveal that water sources indeed may play a hitherto underreported role in spread of ESBL-producing isolates.
Collapse
|
21
|
Dual Detection of the Chytrid Fungi Batrachochytrium spp. with an Enhanced Environmental DNA Approach. J Fungi (Basel) 2021; 7:jof7040258. [PMID: 33808405 PMCID: PMC8065926 DOI: 10.3390/jof7040258] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 03/23/2021] [Accepted: 03/26/2021] [Indexed: 01/24/2023] Open
Abstract
Environmental DNA (eDNA) is becoming an indispensable tool in biodiversity monitoring, including the monitoring of invasive species and pathogens. Aquatic chytrid fungi Batrachochytrium dendrobatidis (Bd) and B. salamandrivorans (Bsal) are major threats to amphibians. However, the use of eDNA for detecting these pathogens has not yet become widespread, due to technological and economic obstacles. Using the enhanced eDNA approach (a simple and cheap sampling protocol) and the universally accepted qPCR assay, we confirmed the presence of Bsal and Bd in previously identified sites in Spain, including four sites that were new for Bsal. The new approach was successfully tested in laboratory conditions using manufactured gene fragments (gBlocks) of the targeted DNA sequence. A comparison of storage methods showed that samples kept in ethanol had the best DNA yield. Our results showed that the number of DNA copies in the Internal Transcribed Spacer region was 120 copies per Bsal cell. Eradication of emerging diseases requires quick and cost-effective solutions. We therefore performed cost-efficiency analyses of standard animal swabbing, a previous eDNA approach, and our own approach. The procedure presented here was evaluated as the most cost-efficient. Our findings will help to disseminate information about efforts to prevent the spread of chytrid fungi.
Collapse
|
22
|
Removal of bisphenol A from aqueous media using a highly selective adsorbent of hybridization cyclodextrin with magnetic molecularly imprinted polymer. ROYAL SOCIETY OPEN SCIENCE 2021; 8:201604. [PMID: 33959329 PMCID: PMC8074973 DOI: 10.1098/rsos.201604] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 01/27/2021] [Indexed: 05/03/2023]
Abstract
In this study, a unique magnetic molecularly imprinted polymer (MMIP) adsorbent towards bisphenol A (BPA) as a template molecule was developed by bulk polymerization using β-cyclodextrin (β-CD) as a co-monomer with methacrylic acid (MAA) to form MMIP MAA-βCD as a new adsorbent. β-CD was hybridized with MAA to obtain water-compactible imprinting sites for the effective removal of BPA from aqueous samples. Benzoyl peroxide and trimethylolpropane trimethacrylate were used as the initiator and cross-linker, respectively. The adsorbents were characterized by Fourier transform infrared spectroscopy, scanning electronic microscopy, transmission electron microscopy, vibrating sample magnetometer, Brunauer-Emmett-Teller and X-ray diffraction. 1H nuclear magnetic resonance spectroscopy was used to characterize the MAA-βCD and BPA-MAA-βCD complex. Several parameters influencing the adsorption efficiency of BPA such as adsorbent dosage, pH of sample solution, contact time, initial concentrations and temperature as well as selectivity and reusability study have been evaluated. MMIP MAA-βCD showed significantly higher removal efficiency and selective binding capacity towards BPA compared to MMIP MAA owing to its unique morphology with the presence of β-CD. The kinetics data can be well described by the pseudo second-order kinetic and Freundlich isotherm and Halsey models best fitted the isotherm data. The thermodynamic studies indicated that the adsorption reaction was a spontaneous and exothermic process. Therefore, MMIP based on the hybrid monomer of MAA-βCD shows good potential of a new monomer in molecularly imprinted polymer preparation and can be used as an effective adsorbent for the removal of BPA from aqueous solutions.
Collapse
|
23
|
Occurrence and Antimicrobial Resistance of Arcobacter spp. Recovered from Aquatic Environments. Antibiotics (Basel) 2021; 10:antibiotics10030288. [PMID: 33802125 PMCID: PMC7998538 DOI: 10.3390/antibiotics10030288] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/26/2021] [Accepted: 03/07/2021] [Indexed: 12/03/2022] Open
Abstract
Arcobacter spp. are emerging waterborne and foodborne zoonotic pathogens responsible for gastroenteritis in humans. In this work, we evaluated the occurrence and the antimicrobial resistance profile of Arcobacter isolates recovered from different aquatic sources. Besides, we searched for Arcobacter spp. in seaweeds and the corresponding seawater samples. Bacteriological and molecular methods applied to 100 samples led to the isolation of 28 Arcobacter isolates from 27 samples. The highest prevalence was detected in rivers followed by artificial ponds, streams, well waters, and spring waters. Seaweeds contained a higher percentage of Arcobacter than the corresponding seawater samples. The isolates were identified as Arcobacter butzleri (96.4%) and Arcobacter cryaerophilus (3.6%). All the isolates showed a multi-drug resistance profile, being resistant to at least three different classes of antibiotics. Molecular analysis of genetic determinants responsible for tetracycline resistance in nine randomly chosen isolates revealed the presence of tetO and/or tetW. This work confirms the occurrence and the continuous emergence of antibiotic-resistant Arcobacter strains in environmental samples; also, the presence of quinolone-resistant Arcobacter spp. in aquatic sources used for water supply and irrigation represents a potential risk for human health.
Collapse
|
24
|
Determination of Polybrominated Diphenyl Ethers in Water Samples Using Effervescent-Assisted Dispersive Liquid-Liquid Icroextraction with Solidification of the Aqueous Phase. Molecules 2021; 26:molecules26051376. [PMID: 33806482 PMCID: PMC7961388 DOI: 10.3390/molecules26051376] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/22/2021] [Accepted: 02/26/2021] [Indexed: 01/20/2023] Open
Abstract
An effective and sensitive method is necessary for the determination of polybrominated diphenyl ethers (PBDEs) pollutants in water. In this study, effervescent-assisted dispersive liquid-liquid microextraction with solidification of the aqueous phase (EA-DLLME-SAP), followed by Gas Chromatography-Tandem Mass Spectrometry (GC-MS-MS) quantitative analysis, was established for the preconcentration and determination of PBDEs in real environmental water samples. 1,1,2,2-Tetrachloroethane was used as the extractant and directly dispersed into the water phase of the aqueous samples with the aid of a large number of carbon dioxide bubbles generated via the acid-base reaction of acetic acid and sodium bicarbonate, which did not require the use of a dispersant during the extraction process. The key factors affecting the extraction recovery were optimized, and an internal standard was used for quantitative analysis, which gave good linearity ranges of 1-100 ng·L-1 (BDEs 28, 47, 99, and 100), 2-200 ng·L-1 (BDEs 153, 154, and 183) and 5-500 ng·L-1 (BDE 209) with limits of quantification in the range of 1.0-5.0 ng·L-1. The accuracy was verified with relative standard deviations < 8.5% observed in tap, lake, river and reservoir water samples with relative recoveries ranging from 67.2 to 102.6%. The presented method contributes to the determination of PBDEs in environmental water samples.
Collapse
|
25
|
Water Sampling Module for Collecting and Concentrating Legionella pneumophila from Low-to-Medium Contaminated Environment. BIOSENSORS 2021; 11:34. [PMID: 33513950 PMCID: PMC7910891 DOI: 10.3390/bios11020034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 01/18/2021] [Accepted: 01/22/2021] [Indexed: 11/17/2022]
Abstract
The detection of water contamination with Legionella pneumophila is of critical importance to manufacturers of water processing equipment and public health entities dealing with water networks and distribution systems. Detection methods based on polymerase chain reaction or biosensor technologies require preconcentration steps to achieve attractive sensitivity levels. Preconcentration must also be included in protocols of automated collection of water samples by systems designed for quasi-continuous monitoring of remotely located water reservoirs for the presence of L. pneumophila. We designed and characterized a water sampling module for filtration and backwashing intended for analysis of low-to-medium contaminated water, typically with L. pneumophila bacteria not exceeding 50 colony-forming units per milliliter. The concentration factors of 10× and 21× were achieved with 0.22 and 0.45 µm filters, respectively, for samples of bacteria prepared in clean saline solutions. However, a 5× concentration factor was achieved with 0.45 µm filters for a heavily contaminated or turbid water typical of some industrial water samples.
Collapse
|
26
|
Multi-Walled Carbon Nanotubes for Magnetic Solid-Phase Extraction of Six Heterocyclic Pesticides in Environmental Water Samples Followed by HPLC-DAD Determination. MATERIALS 2020; 13:ma13245729. [PMID: 33334066 PMCID: PMC7765549 DOI: 10.3390/ma13245729] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/07/2020] [Accepted: 12/13/2020] [Indexed: 12/23/2022]
Abstract
Magnetic multi-walled carbon nanotubes were prepared as magnetic solid-phase extraction (MSPE) adsorbent for the enrichment of six heterocyclic pesticides in environmental water samples, including imidacloprid, triadimefon, fipronil, flusilazole, chlorfenapyr and fenpyroximate. Then six heterocyclic pesticides were separated and determined by high-performance liquid chromatography-diode-array detector (HPLC-DAD). Major factors influencing MSPE efficiency, including the dose of mag-multi-walled carbon nanotubes (mag-MWCNTs), extraction time, solution pH, salt concentration, type and volume of eluent and desorption time were investigated. Under the optimized conditions, the enrichment factor of the method reached to 250. The linearity was achieved within 0.05–10.0 μg/L for imidacloprid and chlorfenapyr, 0.10–10.0 μg/L for fipronil, flusilazole, triadimefon and fenpyroximate. Limits of detection were in the range of 0.01–0.03 μg/L. Good precision at three spiked levels were 1.1–11.2% (intra-day) and 1.7–11.0% (inter-day) with relative standard deviation of peak area, respectively. The developed method was utilized to analyze tap water, river water and reservoir water samples and recoveries at three spiked concentration levels ranged from 72.2% to 107.5%. The method was proved to be a convenient, rapid and practical method for sensitive determination of heterocyclic pesticides.
Collapse
|
27
|
Sample Preparation to Determine Pharmaceutical and Personal Care Products in an All-Water Matrix: Solid Phase Extraction. Molecules 2020; 25:E5204. [PMID: 33182304 PMCID: PMC7664861 DOI: 10.3390/molecules25215204] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/04/2020] [Accepted: 11/05/2020] [Indexed: 12/20/2022] Open
Abstract
Pharmaceuticals and personal care products (PPCPs) are abundantly used by people, and some of them are excreted unaltered or as metabolites through urine, with the sewage being the most important source to their release to the environment. These compounds are in almost all types of water (wastewater, surface water, groundwater, etc.) at concentrations ranging from ng/L to µg/L. The isolation and concentration of the PPCPs from water achieves the appropriate sensitivity. This step is mostly based on solid-phase extraction (SPE) but also includes other approaches (dispersive liquid-liquid microextraction (DLLME), buckypaper, SPE using multicartridges, etc.). In this review article, we aim to discuss the procedures employed to extract PPCPs from any type of water sample prior to their determination via an instrumental analytical technique. Furthermore, we put forward not only the merits of the different methods available but also a number of inconsistencies, divergences, weaknesses and disadvantages of the procedures found in literature, as well as the systems proposed to overcome them and to improve the methodology. Environmental applications of the developed techniques are also discussed. The pressing need for new analytical innovations, emerging trends and future prospects was also considered.
Collapse
|
28
|
Rapid Determination of Parabens in Water Samples by Ultra-high Performance Liquid Chromatography Coupled to Time of Flight Mass Spectrometry. ANAL SCI 2020; 36:675-679. [PMID: 31902828 DOI: 10.2116/analsci.19p409] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Accepted: 11/16/2019] [Indexed: 08/09/2023]
Abstract
An analytical methodology has been developed and validated for the purpose of identifying and quantifying four parabens (methylparaben, ethylparaben, propylparaben and n-butylparaben) in water samples. The combination of rotating disk sorptive extraction (RDSE) technology with ultra-high performance liquid chromatography (UHPLC), along with electrospray ionization source (ESI) and time of flight mass spectrometry (TOF/MS) in trap mode, allowed for eliminating derivatization processes and a reduction of the chromatographic time required, achieving a greener analytical method. In this method, detection limits and precision (%RSD) were lower than 0.018 μg L-1 and lower than 9.7% for all the parabens, respectively, being better than similar works. Matrix effect and absolute recoveries were studied in tap and sewage water samples to observe suppressions of the signals for all analytes, and absolute recoveries were around 60%. This methodology was applied to the analysis of two sewage samples (punctual and composite) obtained from locations in Santiago, Chile.
Collapse
|
29
|
Chlortetracycline-Functionalized Silver Nanoparticles as a Colorimetric Probe for Aminoglycosides: Ultrasensitive Determination of Kanamycin and Streptomycin. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E997. [PMID: 32455981 PMCID: PMC7279544 DOI: 10.3390/nano10050997] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 05/20/2020] [Indexed: 12/23/2022]
Abstract
Aminoglycosides (AMGs) have been extensively used to treat infectious diseases caused by Gram-negative bacteria in livestock and humans. A selective and sensitive colorimetric probe for the determination of streptomycin and kanamycin was proposed based on chlortetracycline-coated silver nanoparticles (AgNPs-CTC) as the sensing element. Almost all of the tested aminoglycoside antibiotics can rapidly induce the aggregation of AgNPs, along with a color change from yellow to orange/red. The selective detection of aminoglycoside antibiotics, including tobramycin, streptomycin, amikacin, gentamicin, neomycin, and kanamycin, with other types of antibiotics, can be achieved by ultraviolet (UV) spectroscopy. This developed colorimetric assay has ability to detect various AMGs using in-depth surface plasmon resonance (SPR) studies. With this determination of streptomycin and kanamycin was achieved at the picomolar level (pM) by using a UV-visible spectrophotometer. Under aqueous conditions, the linear range of the colorimetric sensor for streptomycin and kanamycin was 1000-1,1000 and 120-480 pM, respectively. The corresponding limit of detection was 2000 pM and 120 pM, respectively. Thus, the validated dual colorimetric and ratiometric method can find various analytical applications for the ultrasensitive and rapid detection of AMG antibiotics in water samples.
Collapse
|
30
|
Magnetic nanoparticles assisted dispersive liquid-liquid microextraction of chloramphenicol in water samples. ROYAL SOCIETY OPEN SCIENCE 2020; 7:200143. [PMID: 32431904 PMCID: PMC7211875 DOI: 10.1098/rsos.200143] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 03/13/2020] [Indexed: 06/11/2023]
Abstract
This work describes the development of a new methodology based on magnetic nanoparticles assisted dispersive liquid-liquid microextraction (DLLME-MNPs) for preconcentration and extraction of chloramphenicol (CAP) antibiotic residues in water. The approach is based on the use of decanoic acid as the extraction solvent followed by the application of MNPs to magnetically retrieve the extraction solvent containing the extracted CAP. The coated MNPs were then desorbed with methanol, and the clean extract was analysed using ultraviolet-visible spectrophotometry. Several important parameters, such as the amount of decanoic acid, extraction time, stirring rate, amount of MNPs, type of desorption solvent, salt addition and sample pH, were evaluated and optimized. Optimum parameters were as follows: amount of decanoic acid: 200 mg; extraction time: 10 min; stirring rate: 800 rpm; amount of MNPs: 60 mg; desorption solvent: methanol; salt: 10%; and sample pH, 8. Under the optimum conditions, the method demonstrated acceptable linearity (R 2 = 0.9933) over a concentration range of 50-1000 µg l-1. Limit of detection and limit of quantification were 16.5 and 50.0 µg l-1, respectively. Good analyte recovery (91-92.7%) and acceptable precision with good relative standard deviations (0.45-6.29%, n = 3) were obtained. The method was successfully applied to tap water and lake water samples. The proposed method is rapid, simple, reliable and environmentally friendly for the detection of CAP.
Collapse
|
31
|
Ratiometric Strategy for Electrochemical Sensing of Carbaryl Residue in Water and Vegetable Samples. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1524. [PMID: 32164236 PMCID: PMC7085720 DOI: 10.3390/s20051524] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 03/01/2020] [Accepted: 03/06/2020] [Indexed: 11/16/2022]
Abstract
Accurate analysis of pesticide residue in real samples is essential for food safety and environmental protection. However, a traditional electrochemical sensor based on single-signal output is easily affected by background noise, environmental conditions, electrode diversity, and a complex matrix of samples, leading to extremely low accuracy. Hence, in this paper, a ratiometric strategy based on dual-signal output was adopted to build inner correction for sensing of widely-used carbaryl (CBL) for the first time. By comparison, Nile blue A (NB) was selected as reference probe, due to its well-defined peak, few effects on the target peak of CBL, and excellent stability. The effects of a derivatization method, technique mode, and pH were also investigated. Then the performance of the proposed ratiometric sensor was assessed in terms of three aspects including the elimination of system noise, electrode deviation and matrix effect. Compared with traditional single-signal sensor, the ratiometric sensor showed a much better linear correlation coefficient (r > 0.99), reproducibility (RSD < 10%), and limit of detection (LOD = 1.0 μM). The results indicated the introduction of proper reference probe could ensure the interdependence of target and reference signal on the same sensing environment, thus inner correction was fulfilled, which provided a promising tool for accurate analysis.
Collapse
|
32
|
[Hydrochemical and Isotopic Characteristics of the Lake Balkhash Catchment, Kazakhstan]. HUAN JING KE XUE= HUANJING KEXUE 2020; 41:173-182. [PMID: 31854918 DOI: 10.13227/j.hjkx.201905220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Lake Balkhash is one of the largest lakes in the world. It is located in arid Central Asia and receives major water from the Ili River, which is an international river flowing across China and Kazakhstan. Hydrochemical and isotopic measurements of waters can provide an improved understanding of hydrogeochemical processes and environmental characteristics, which is useful for water resource management in arid regions. In this study, δD, δ18 O, and major ions in water samples from the Lake Balkhash catchment were analyzed using an integration of mathematical statistics, Piper diagrams, Gibbs model, and principal component analysis (PCA). Water types and main mechanisms controlling the hydrochemistry presented a clear spatial heterogeneity. The chemical composition of lake waters was dominated by SO4-Na and Cl-Na type, whereas river waters were classified as a HCO3-Ca type. The chemical composition downstream of the Ili River evolved from HCO3-Ca to SO4-Na-Cl type. Gibbs model suggested that the main mechanisms controlling the lake water chemistry were evaporation-crystallization processes, and that major ions in the river water were affected by rock-weathering and evaporation processes. The main controlling factors of the water chemistry changed from the upstream to the downstream, and may have related to spatial differences whereby the upstream area experienced higher rainfall and snow melt, and the downstream area experienced relatively higher evaporation. PCA analysis showed that human activities also played an important role in the chemical composition of water sampled from the lake, middle and lower reaches of the Ili River, and other rivers. The isotopic compositions of the lake and river waters varied spatially. In the lake waters, positive isotopic ratios and negative deuterium-excess values indicated that evaporitic enrichment dominated the changes in the isotopic signature of the lake water. In river waters, isotope values located near the global meteoric water line (GMWL) and lower slopes of the regression lines (r=0.91, P<0.001 for Ili River, and r=0.63, P<0.001 for other rivers), were associated with a stronger influence of rainfall and weaker evaporation. Correlation analysis showed that there were significant relationships between isotope values and chemical parameters in the lake water, especially in the eastern area, thus suggesting that extensive evaporation led to simultaneous enrichment of isotopes and ions in the lake water.
Collapse
|
33
|
Quantification of Trace Mercury in Water: Solving the Problem of Adsorption, Sample Preservation, and Cross-Contamination. GLOBAL CHALLENGES (HOBOKEN, NJ) 2020; 4:1900061. [PMID: 31956428 PMCID: PMC6957015 DOI: 10.1002/gch2.201900061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 10/10/2019] [Indexed: 06/10/2023]
Abstract
Adsorption, sample preservation, and cross-contamination are the major impediments to the accurate and sensitive analysis of low-level mercury samples. Common measures to deal with this issue are to use Teflon, quartz, or borosilicate glass bottles for sampling, standard solution and sample preservation with oxidative chemicals, to prepare standard solutions daily and to use dedicated glassware. This paper demonstrates that these measures are neither efficient nor effective. Two common laboratory sample containers (borosilicate volumetric glass flasks and polypropylene tubes) are investigated for the preparation and preservation of water samples and standard solutions of 0.2-1 µg L-1 with 2% HNO3. Mercury adsorption rates of 6-22% are observed within 30 min and after 48 days, the adsorption is greater than 98%. In stark contrast, no adsorption is found during a testing period of 560 days when the solutions are subject to potassium permanganate-persulfate digestion. New glass flasks and polypropylene bottles are free of mercury contamination but reused flasks are a major source of mercury cross-contamination. To minimize adsorption and cross-contamination, standard solutions are treated by potassium permanganate-persulfate or BrCl digestion, and each individual sample and standard solution should be stored and prepared in single-use polypropylene bottle, without transference.
Collapse
|
34
|
Micelles Mediated Zone Fluidics Method for Hydrazine Determination in Environmental Samples. Molecules 2019; 25:E174. [PMID: 31906217 PMCID: PMC6983152 DOI: 10.3390/molecules25010174] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 12/22/2019] [Accepted: 12/27/2019] [Indexed: 01/30/2023] Open
Abstract
An automated flow method for the determination of hydrazine based on the concept of zone-fluidics has been developed. The analyte reacts under flow conditions with p-dimethylamino benzaldehyde (25 mmol L-1) in micellar medium (100 mmol L-1 SDS) to form a stable derivative (460 nm). Micelles mediated catalysis excludes the use of highly acidic environment typical for this kind of reaction. Following careful examination of chemical and instrumental variables, the method allows the determination of hydrazine at the low micromolar level (0.3-10 μmol L-1) in water samples. Real sample analyses (drinking and boiler feed water) resulted in satisfactory results in terms of accuracy with the percent recoveries being in the range of 82-114%.
Collapse
|
35
|
Investigation of Blastocystis Subspecies in Water Samples Collected from Ordu Province. TURKISH JOURNAL OF PARASITOLOGY 2019; 43:111-117. [PMID: 31502772 DOI: 10.4274/tpd.galenos.2019.5976] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Objective The aim of the study was to determine the prevalence of Blastocystis subspecies in water samples collected from Ordu province. Methods Seventy-five surface water samples and 25 drinking water samples were collected from Ordu and its boroughs. The samples were flocculated by aluminum sulphate and concentrated by sucrose gradient method. Small subunit ribosomal RNA (SSU rRNA) gene was amplified by polymerase chain reaction (PCR). Sequence analysis was performed on the positive PCR products and the base sequences were aligned using Bioedit. Phylogeny trees were drawn and Blastocystis subspecies were identified. Results Four out of the 100 water samples were positive for Blastocystis spp. No positivity was found in the drinking water. Blastocystis ST-1 subspecies was detected in Bülbül River, Kacalı River and Bolaman Stream. Blastocystis ST-3 subspecies were found in Karabalçık River. The lowest genetic distance was found between ST-1 subspecies and the samples from Bülbül River, Kacalı River and Bolaman Stream. The nucleotide similarities between them were 98.8%, 76.6 and 98.8%, respectively. The lowest genetic distance was found between Karabalçık River and ST-3 subspecies and the nucleotide similarity between them was 99.1%. Conclusion This is the first study on the presence of Blastocystis spp. in the surface water and drinking water samples in Ordu province of the Black Sea area in Turkey.
Collapse
|
36
|
A Redox-Switchable Colorimetric Probe for "Naked-Eye" Detection of Hypochlorous Acid and Glutathione. Molecules 2019; 24:molecules24132455. [PMID: 31277409 PMCID: PMC6651190 DOI: 10.3390/molecules24132455] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 06/27/2019] [Accepted: 07/03/2019] [Indexed: 12/05/2022] Open
Abstract
We report the development of a new colorimetric probe (L-ol) for investigations of the redox process regulated by hypochlorous acid (HOCl) and glutathione (GSH). The HOCl/GSH redox-switching cycle process was investigated in detail by UV-vis absorption spectroscopy, colorimetric analysis assay and high-resolution mass spectrometry (HRMS). The switchable absorbance responses were attributed to the HOCl-induced oxidation of the p-methoxyphenol unit to the benzoquinone derivative (L-one) and sequential reduction of L-one to hydroquinone (L-ol’) by GSH. In phosphate-buffered saline (PBS) buffer, the absorbance of L-ol at 619 nm underwent a remarkable bathochromic-shift, accompanied by a color change from pale yellow to blue in the presence of HOCl. With further addition of GSH, the absorbance of L-one exclusively recovered to the original level. Meanwhile, the blue-colored solution returned to the naive pale yellow color in the presence of GSH. The detection limits for HOCl and GSH were calculated to be 6.3 and 96 nM according to the IUPAC criteria. Furthermore, L-ol-loaded chromatography plates have been prepared and successfully applied to visualize and quantitatively analyze HOCl in several natural waters.
Collapse
|
37
|
Dispersive liquid-liquid microextraction coupled with pressure-assisted electrokinetic injection for simultaneous enrichment of seven phenolic compounds in water samples followed by determination using capillary electrophoresis. J Sep Sci 2019; 42:2263-2271. [PMID: 30997953 DOI: 10.1002/jssc.201900106] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 04/15/2019] [Accepted: 04/15/2019] [Indexed: 11/09/2022]
Abstract
Offline dispersive liquid-liquid microextraction combined with online pressure-assisted electrokinetic injection was developed to simultaneously enrich seven phenolic compounds in water samples, followed by determination using capillary electrophoresis, namely phenol, 4-chlorophenol, pentachlorophenol, 2,4,6-trichlorophenol, 2,4-dichlorophenol, 2-chlorophenol, and 2,6-dichlorophenol. Several parameters affecting separation performance of capillary electrophoresis and the enrichment efficiency of pressure-assisted electrokinetic injection and dispersive liquid-liquid microextraction were systematically investigated. Under the optimal conditions, seven phenolic compounds were completely separated within 14 min and good enrichment factors were obtained of 61, 236, 3705, 3288, 920, 86, and 1807 for phenol, 4-chlorophenol, pentachlorophenol, 2,4,6-trichlorophenol, 2,4-dichlorophenol, 2-chlorophenol, and 2,6-dichlorophenol, respectively. Good linearity was attained in the range of 0.1-200 μg/L for 2,4-dichlorophenol, 0.5-200 μg/L for 4-chlorophenol, pentachlorophenol, 2,4,6-trichlorophenol, 2-chlorophenol, and 2,6-dichlorophenol, as well as 1-200 μg/L for phenol, with correlation coefficients (r) over 0.9905. The limits of detection and quantification ranging from 0.03-0.28 and 0.07-0.94 μg/L were attained. This two step enrichment method was potentially applicable for the rapid and simultaneous determination of phenolic compounds in water samples.
Collapse
|
38
|
[Determination of sulfonylurea herbicides in water samples by high performance liquid chromatography coupled with on-line magnetic solid phase extraction using trimethylstearylammonium-bromide-modified magnetic particles]. Se Pu 2019; 37:259-264. [PMID: 30900853 DOI: 10.3724/sp.j.1123.2018.10028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
A magnetic particle with a trimethylstearylammonium-bromide-modified surface was prepared as an adsorbent by a sol-gel method. An on-line magnetic solid phase extraction (MSPE) device was established and used for extraction and preconcentration of two sulfonylurea herbicides (SUHs) (chlorsulfuron and bensulfuron-methyl) in water samples prior to high-performance liquid chromatography. On-line MSPE parameters were optimized, including desorption conditions, adsorbent dose, pH of the sample solution, and injection flow rate. Under the optimum conditions, satisfactory linearity was obtained (correlation coefficients ≥ 0.9997). The limits of detection (LODs) of chlorsulfuron and bensulfuron-methyl were 0.32 and 1.12 μg/L, respectively. The method was successfully applied to determine two sulfonylurea herbicides in three types of environmental water samples. The recoveries of sulfonylurea herbicides were in the range of 70.0%-113.4%. The results confirmed that this method is efficient and simple and has a wide application potential in separation and enrichment of sulfonylurea herbicides in environmental water samples.
Collapse
|
39
|
Design and Synthesis of a Fluorescent Probe with a Large Stokes Shift for Detecting Thiophenols and Its Application in Water Samples and Living Cells. Molecules 2019; 24:molecules24020375. [PMID: 30669672 PMCID: PMC6359167 DOI: 10.3390/molecules24020375] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 01/18/2019] [Accepted: 01/21/2019] [Indexed: 12/13/2022] Open
Abstract
A turn-on florescent probe (probe-KCP) was developed for highly selective detection of thiophenols based on a donor-excited photo-induced electron transfer mechanism. Herein, the synthesis of the probe, a chalcone derivative, through a simple straightforward combination of a carbazole-chalcone fluorophore with a 2,4-dinitrophenyl functional group. In a kinetic study of the probe-KCP for thiophenols, the probe displayed a short response time (~30 min) and significant fluorescence enhancement. In selection and competition experiments, the probe-KCP exhibited excellent selectivity for thiophenols over glutathione (GSH), cysteine (Cys), sodium hydrosulfide (NaSH), and ethanethiol (C2H5SH) in addition to common anions and metal ions. Using the designed probe, we successfully monitored and quantified thiophenols, which are highly toxic. This turn-on fluorescence probe features a remarkably large Stokes shift (130 nm) and a short response time (30 min), and it is highly selective and sensitive (~160-fold) in the detection of thiophenols, with marked fluorescence in the presence of thiophenols. probe-KCP responds to thiophenols with a good range of linearity (0–15 μM) and a detection limit of 28 nM (R2 = 0.9946) over other tested species mentioned including aliphatic thiols, thiophenol analogues, common anions, and metal ions. The potential applications of this carbazole-chalcone fluorescent probe was successfully used to determine of thiophenols in real water samples and living cells with good performance and low cytotoxicity. Therefore, this probe has great potential application in environment and biological samples.
Collapse
|
40
|
A Sensitive Near-Infrared Fluorescent Probe for Detecting Heavy Metal Ag⁺ in Water Samples. SENSORS (BASEL, SWITZERLAND) 2019; 19:E247. [PMID: 30634622 PMCID: PMC6358871 DOI: 10.3390/s19020247] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 01/07/2019] [Accepted: 01/07/2019] [Indexed: 11/17/2022]
Abstract
Silver is a common catalyst in industrial production, and the frequent use of Ag⁺ can cause water pollution. Thus, the detection of Ag⁺ in the environment is necessary to determine the level of pollution from silver. In this work, we designed a new, highly selective near-infrared (NIR) fluorescent probe QCy to detect Ag⁺. The probe exhibits "turn-off" fluorescence quenching responses at 760 nm towards Ag⁺ over other relevant cations, with outstanding sensitivity and a low detection limit (0.03 µM), which is considerably lower than the standard of the World Health Organization (WHO) for drinking water (0.9 µM). Meanwhile, QCy showed a very good linearity at a low concentration of Ag⁺ with a 'naked eye' visible color change of solution from blue to red. The probe has been applied successfully for the detection of Ag⁺ in real water samples.
Collapse
|
41
|
Determination of 23 perfluorinated alkylated substances in water and suspended particles by ultra-performance liquid chromatography/tandem mass spectrometry. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2019; 53:1277-1283. [PMID: 30623697 DOI: 10.1080/10934529.2018.1528042] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 09/20/2018] [Accepted: 06/16/2018] [Indexed: 06/09/2023]
Abstract
A practical multi-residue method based on ultra-performance liquid chromatography/tandem mass spectrometry was developed for the simultaneous determination of 23 perfluorinated alkylated substances (PFASs) in water and suspended particles. Suspended particle samples were extracted with 1% formic acid-acetonitrile and cleaned by matrix solid phase dispersion extraction using a C18 sorbent and graphitized carbon black. Water samples were filtered through 0.7-μm glass fiber membranes and enriched utilizing weak anion exchange cartridges. The eluent was dried under a gentle stream of N2 at 45°C and suspended in 1 mL acetonitrile-5 mM ammonium acetate (1:1, vol:vol). Gradient elution for chromatographic separation utilized acetonitrile and 5 mM ammonium acetate as mobile phases on a reverse phase C18 column. The compounds were quantified using an internal standard method in multiple reaction-monitoring mode. Limits of detection and quantitation of the 23 PFAS test compounds in water samples were 0.5-10 ng L-1 and 2-20 ng L-1, respectively. Recoveries at three fortified levels of 20, 50, and 200 ng L-1 ranged from 68.5% to 118% with relative standard deviations below 9.6%. We used this method to determine PFAS levels in real water and suspended particle samples and found high sensitivity and good reproducibility.
Collapse
|
42
|
Molecularly imprinted polymers for the detection of benomyl residues in water and soil samples. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART. B, PESTICIDES, FOOD CONTAMINANTS, AND AGRICULTURAL WASTES 2019; 54:702-708. [PMID: 31112093 DOI: 10.1080/03601234.2018.1473970] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Benomyl is a benzimidazol fungicide used against various crop pathogens. Although banned in many countries, it is still widely used worldwide and is listed in different monitoring programs among the substances to be monitored to assess human exposure to pesticide residues. The assessment of benomyl is mainly based on the analysis of the residues of its most important metabolite, carbendazim. Existing methods often lack of selectivity and display a limited performance because of the presence of co-extracted compounds. Molecularly imprinted polymers (MIPs) offer an alternative methodology, adsorbing preferentially those target molecules for which the polymers are specifically prepared. In this study, we optimized the synthesis of a polymer imprinted with benomyl. Tests of specificity recognition showed a good performance for carbendazim compared with other similar pesticides. The mean recovery of benomyl (measured as carbendazim) from water samples was estimated to be 90% for MIPs while with real soil samples collected in Morocco the recovery efficiency was 62%. Preliminary tests also suggest that this MIP can implement traditional SPE techniques for assessing benomyl residual concentrations in environmental samples.
Collapse
|
43
|
Ultrafast and Energy-saving Synthesis of Nitrogen and Chlorine Co-doped Carbon Nanodots via Neutralization Heat for Selective Detection of Cr(VI) in Aqueous Phase. SENSORS (BASEL, SWITZERLAND) 2018; 18:E3416. [PMID: 30314392 PMCID: PMC6210692 DOI: 10.3390/s18103416] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2018] [Revised: 10/09/2018] [Accepted: 10/09/2018] [Indexed: 01/29/2023]
Abstract
In this work, it is presented for the first time that nitrogen and chlorine co-doped carbon nanodots (N,Cl-CDs) were synthesized by simply mixing glucose, concentrated hydrochloric acid (HCl), and 1,2-ethylenediamine (EDA). No external heat was employed; the neutralization reaction served as the heat source. The glucose served as the carbon source while EDA and HCl were the N and Cl dopants, respectively. The fluorescence of N,Cl-CDs was adequately quenched by hexavalent chromium Cr(VI) based on a combination of dynamic quenching and inner filter effect (IFE). Accordingly, an efficient N,Cl-CDs-based fluorescence probe was established for sensitive and selective detection of Cr(VI). The proposed fluorescence sensor provides a linear recognition range for Cr(VI) determination from 3 to 40 µM with a limit of detection (LOD) of 0.28 µM (14.6 µg/L). The proposed fluorescence method was successfully utilized to detect Cr(VI) in different water samples with satisfactory results. The spike recoveries vary from 97.01% to 103.89% with relative standard deviations (RSDs) of less than 0.82%. This work highlights the development of a simple, ultrafast, and energy-saving one-step synthetic route to fabricate N,Cl-CDs for highly selective and sensitive detection of Cr(VI) in real water samples. It is anticipated that the proposed fluorescence method could be further explored and widely used for Cr(VI) detection in the environmental industry.
Collapse
|
44
|
Determination of Trace Nickel in Water Samples by Graphite Furnace Atomic Absorption Spectrometry after Mixed Micelle-Mediated Cloud Point Extraction. Molecules 2018; 23:molecules23102597. [PMID: 30309038 PMCID: PMC6222332 DOI: 10.3390/molecules23102597] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Revised: 09/26/2018] [Accepted: 09/27/2018] [Indexed: 11/16/2022] Open
Abstract
A simple and sensitive cloud point extraction method for the preconcentration of ultra-trace amounts of nickel as a prior step to its determination by graphite furnace atomic absorption spectrometry was proposed. It is based on the reaction of nickel with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in HAc–NaAc buffer media and mixed micelle-mediated extraction of the complex using the anionic surfactant sodium dodecyl sulfate sodium (SDS) and non-ionic surfactant (1,1,3,3-Tetramethylbutyl)phenyl-polyethylene (Triton X-114). The optimal reaction and extraction conditions such as pH, concentration of 5-Br-PADMA, SDS and Triton X-114, equilibrium temperature, incubation, and centrifuge time were evaluated and optimized. Under the optimal conditions, the calibration graph was linear over the range 0.1–5.5 ng/mL of nickel with a correlation coefficient of 0.9942. The detection limit obtained was 0.031 ng/mL, and the relative standard deviation was 2.1% for nickel (c = 2 ng/mL, n = 6). The proposed method was successfully applied to the determination of nickel in water samples.
Collapse
|
45
|
[Determination of four phenolic estrogens in water samples by pressure-assisted electrokinetic injection coupled with capillary electrophoresis]. Se Pu 2018; 36:573-577. [PMID: 30136480 DOI: 10.3724/sp.j.1123.2018.01011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
A capillary electrophoresis (CE) method was developed for the simultaneous separation and determination of four phenolic estrogens (PEs), in which pressure-assisted electrokinetic injection (PAEKI) was adopted as the on-line concentration method to enrich the PEs. Several parameters affecting PAEKI conditions such as injection voltage and injection time, were systematically investigated and compared with the usual parameters. Under the optimized PAEKI conditions (-9 kV, 0.3 psi (ca. 2.1 kPa), 0.4 min), the four PEs separated completely within 7 min. Good linearities were attained in the range of 0.05-5 mg/L for hexestrol and dienestrol, and 0.1-10 mg/L for bisphenol A and diethylstilbestrol, with correlation coefficients (r) over 0.9936. The limits of detection (S/N=3) were 0.0071-0.017 mg/L, and enrichment factors ranged from 11 to 15 compared to normal hydrodynamic injection. The combined micellar electrokinetic chromatographic-PAEKI method developed was used to determine the PEs in tap water and lake water samples; limits of quantification (S/N=10) of 0.029-0.064 mg/L and 0.033-0.079 mg/L were attained, respectively, by the two sample types. Furthermore, recoveries ranged from 75.6% to 110.1% with relative standard deviations (n=5) within 4.6%-11.8%. To use this PAEKI method, researchers would only need to adjust the parameters of the CE apparatus to perform on-line enrichment of analytes, without using other reagents; this demonstrates the simplicity, rapidity, and highly automated nature of this method.
Collapse
|
46
|
Ultrasonically Modified Amended-Cloud Point Extraction for Simultaneous Pre-Concentration of Neonicotinoid Insecticide Residues. Molecules 2018; 23:E1165. [PMID: 29757232 PMCID: PMC6100087 DOI: 10.3390/molecules23051165] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 05/08/2018] [Accepted: 05/10/2018] [Indexed: 11/20/2022] Open
Abstract
An effective pre-concentration method, namely amended-cloud point extraction (CPE), has been developed for the extraction and pre-concentration of neonicotinoid insecticide residues. The studied analytes including clothianidin, imidacloprid, acetamiprid, thiamethoxam and thiacloprid were chosen as a model compound. The amended-CPE procedure included two cloud point processes. Triton™ X-114 was used to extract neonicotinoid residues into the surfactant-rich phase and then the analytes were transferred into an alkaline solution with the help of ultrasound energy. The extracts were then analyzed by high-performance liquid chromatography (HPLC) coupled with a monolithic column. Several factors influencing the extraction efficiency were studied such as kind and concentration of surfactant, type and content of salts, kind and concentration of back extraction agent, and incubation temperature and time. Enrichment factors (EFs) were found in the range of 20⁻333 folds. The limits of detection of the studied neonicotinoids were in the range of 0.0003⁻0.002 µg mL−1 which are below the maximum residue limits (MRLs) established by the European Union (EU). Good repeatability was obtained with relative standard deviations lower than 1.92% and 4.54% for retention time (tR) and peak area, respectively. The developed extraction method was successfully applied for the analysis of water samples. No detectable residues of neonicotinoids in the studied samples were found.
Collapse
|
47
|
[Determination of phthalates in water by dispersive liquid-liquid microextraction based on solidification of floating organic drop followed by high performance liquid chromatography]. Se Pu 2018; 36:452-457. [PMID: 30136486 DOI: 10.3724/sp.j.1123.2017.11060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
A rapid method for the determination of six phthalates (PAEs) in water samples was established by dispersive liquid-liquid microextraction (DLLME) based on solidification of floating organic drop (SFO) coupled with high performance liquid chromatography (HPLC). The influences of the SFO-DLLME parameters on extraction efficiencies were studied. Dodecanol (extraction solvent, 20 μL) was added to the water samples (containing 20 g/L NaCl) at 60℃, and the solution was shaken for 1 min. The results showed that the six PAEs were linear in the range of 2-2000 μg/L with correlation coefficients (r) between 0.9995 and 0.9999. The limits of detection (S/N=3) of the six PAEs ranged from 0.3 to 0.6 μg/L. The proposed method was applied to the analysis of the seven water samples obtained from different sources (tap water, lake water, river water, waste water, sea water, plastic bottled pure water and mineral water), and some PAEs were detected. The recoveries of the six PAEs in the spiked water samples were 84.9%-94.5%, and relative standard deviations were 4.1%-6.8% at three levels of 10, 100 and 1000 μg/L. The method is an environmentally friendly and convenient method for the routine analysis of the PAEs in water samples.
Collapse
|
48
|
[Determination of organophosphorus and carbamate insecticide residues in food and water samples by solid phase extraction coupled with capillary liquid chromatography]. Se Pu 2018; 36:30-36. [PMID: 29582610 DOI: 10.3724/sp.j.1123.2017.09023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
A method was established for the simultaneous separation and determination of one organophosphorus and three carbamate insecticide residues in food and water samples by solid phase extraction (SPE) followed by analysis using a home-made capillary liquid chromatogram. Various parameters possibly affecting the efficiencies of capillary liquid chromatography (CLC) and SPE were investigated in detail, such as type of SPE column, pH value of samples, type and volume of elution solvent, flow rate of loading sample, salt effect, loading volume, detection wavelength, and type and ratio of mobile phases. Under the optimized experimental conditions, the four insecticides were separated completely within 6 min. The limits of detection and limits of quantification were 0.35-1.20 μg/kg and 1.17-4.00 μg/kg, respectively. Satisfactory recoveries of the SPE-CLC method were achieved for spiked food samples of tomato, cucumber and apple ranging from 72.41% to 107.15% with the relative standard deviations (RSDs) no more than 8.12%, and for spiked tap/lake water samples ranging from 71.45% to 109.25% with the RSDs no more than 9.28%. The method can meet the requirements for multi-residue analysis of insecticides.
Collapse
|
49
|
CE method for analyzing Salmonella typhimurium in water samples. J Sep Sci 2017; 41:534-539. [PMID: 29087615 DOI: 10.1002/jssc.201700705] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Revised: 10/19/2017] [Accepted: 10/22/2017] [Indexed: 01/10/2023]
Abstract
Salmonella typhimurium is commonly described as a food-borne pathogen. However, natural and drinking water are known to be important sources for the transmission of this pathogen in developing and developed countries. The standard method to determine Salmonella is laborious and many false positives are detected. To solve this, the present work was focused on the development of a capillary zone electrophoresis method coupled to ultraviolet detection for determination of Salmonella typhimurium in water (mineral and tap water). Separations were performed in less than 11 minutes using 4.5 mM Tris (hydroxymethyl)-aminomethane, 4.5 mM boric acid and 0.1 mM ethylene diamine tetraacetate (pH 8.4) with 0.1% v/v poly ethylene oxide as separation buffer. The precision of the method was evaluated in terms of repeatability obtaining a relative standard deviation of 10.5%. Using the proposed method Salmonella typhimurium could be separated from other bacteria that could be present in water such as Escherichia coli. Finally, the proposed methodology was applied to determine Salmonella typhimurium in tap and mineral water.
Collapse
|
50
|
Solid-phase nanoextraction of polychlorinated biphenyls in water and their determination by gas chromatography with electron capture detector. J Sep Sci 2016; 40:449-457. [PMID: 27958677 DOI: 10.1002/jssc.201600720] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 09/19/2016] [Accepted: 10/24/2016] [Indexed: 12/21/2022]
Abstract
A solid-phase nanoextraction method has been developed for the extraction and preconcentration of polychlorinated biphenyls using carboxyl multiwalled carbon nanotubes as a solid nano-sorbent. Parameters affecting extraction efficiency such as sorbent amount, desorption solvent type and volume, extraction time, pH, and salt content have been studied. Under optimized conditions, the correlation coefficient was up to 0.9989, the limits of detection was in the range of 1.4-3.5 ng/L, and limits of quantification was between 4.8 and 11.6 ng/L. The recoveries were in the range of 99-106% for different spiked analytes. The relative standard deviation for water samples spiked with two different spiking levels has been between 4 and 10%. The proposed sustainable method is rapid, easy to use, and small consumption of organic solvent for the detection and determination of trace levels of polychlorinated biphenyls in environmental waters.
Collapse
|