101
|
Abstract
The use of glucagon, in conjunction with insulin, in a dual chamber pump (artificial pancreas, AP) is a working goal for multiple companies and researchers. However, capital investment to create, operate, and maintain facilities with sufficient scale to produce enough glucagon to treat millions of patients, at a level of profit that makes it feasible, will be substantial. It can be assumed that the marketplace will expect the daily cost of glucagon (to the consumer) to be similar to the daily cost of insulin. After one subtracts wholesaler and pharmacy markup, there may be very few dollars remaining for the drug company to cover profit, capital expenditures, marketing, burden, and other costs. Without the potential for adequate margins, manufacturers may not be willing to take the risk. Assuming that the projections discussed in this article are in the right ballpark, advance planning for the supply for glucagon needs to start today and not wait for the AP to come to market.
Collapse
|
102
|
|
103
|
Bakhtiani PA, El Youssef J, Duell AK, Branigan DL, Jacobs PG, Lasarev MR, Castle JR, Ward WK. Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes. J Diabetes Complications 2015; 29:93-8. [PMID: 25264232 PMCID: PMC4281277 DOI: 10.1016/j.jdiacomp.2014.09.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 08/31/2014] [Accepted: 09/03/2014] [Indexed: 12/31/2022]
Abstract
BACKGROUND In bi-hormonal closed-loop systems for treatment of diabetes, glucagon sometimes fails to prevent hypoglycemia. We evaluated glucagon responses during several closed-loop studies to determine factors, such as gain factors, responsible for glucagon success and failure. METHODS We extracted data from four closed-loop studies, examining blood glucose excursions over the 50min after each glucagon dose and defining hypoglycemic failure as glucose values<60 mg/dl. Secondly, we evaluated hyperglycemic excursions within the same period, where glucose was>180 mg/dl. We evaluated several factors for association with rates of hypoglycemic failure or hyperglycemic excursion. These factors included age, weight, HbA1c, duration of diabetes, gender, automation of glucagon delivery, glucagon dose, proportional and derivative errors (PE and DE), insulin on board (IOB), night vs. day delivery, and point sensor accuracy. RESULTS We analyzed a total of 251 glucagon deliveries during 59 closed-loop experiments performed on 48 subjects. Glucagon successfully maintained glucose within target (60-180 mg/dl) in 195 (78%) of instances with 40 (16%) hypoglycemic failures and 16 (6%) hyperglycemic excursions. A multivariate logistic regression model identified PE (p<0.001), DE (p<0.001), and IOB (p<0.001) as significant determinants of success in terms of avoiding hypoglycemia. Using a model of glucagon absorption and action, simulations suggested that the success rate for glucagon would be improved by giving an additional 0.8μg/kg. CONCLUSION We conclude that glucagon fails to prevent hypoglycemia when it is given at a low glucose threshold and when glucose is falling steeply. We also confirm that high IOB significantly increases the risk for glucagon failures. Tuning of glucagon subsystem parameters may help reduce this risk.
Collapse
|
104
|
Pohl R, Li M, Krasner A, De Souza E. Development of stable liquid glucagon formulations for use in artificial pancreas. J Diabetes Sci Technol 2015; 9:8-16. [PMID: 25352634 PMCID: PMC4495524 DOI: 10.1177/1932296814555541] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A promising approach to treat diabetes is the development of fully automated artificial/bionic pancreas systems that use both insulin and glucagon to maintain euglycemia. A physically and chemically stable liquid formulation of glucagon does not currently exist. Our goal is to develop a glucagon formulation that is stable as a clear and gel-free solution, free of fibrils and that has the requisite long-term shelf life for storage in the supply chain, short-term stability for at least 7 days at 37°C, and pump compatibility for use in a bihormonal pump. We report the development of two distinct families of stable liquid glucagon formulations which utilize surfactant or surfactant-like excipients (LMPC and DDM) to "immobilize" the glucagon in solution potentially through the formation of micelles and prevention of interaction between glucagon molecules. Data are presented that demonstrate long-term physical and chemical stability (~2 years) at 5°C, short-term stability (up to 1 month) under accelerated 37°C testing conditions, pump compatibility for up to 9 days, and adequate glucose responses in dogs and diabetic swine. These stable glucagon formulations show utility and promise for further development in artificial pancreas systems.
Collapse
|
105
|
Newswanger B, Ammons S, Phadnis N, Ward WK, Castle J, Campbell RW, Prestrelski SJ. Development of a highly stable, nonaqueous glucagon formulation for delivery via infusion pump systems. J Diabetes Sci Technol 2015; 9:24-33. [PMID: 25550410 PMCID: PMC4495537 DOI: 10.1177/1932296814565131] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as "in use" stability and compatibility in an Insulet's OmniPod(®) infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. This nonaqueous glucagon formulation is suitable for further clinical development in pump systems.
Collapse
|
106
|
Bakhtiani PA, Caputo N, Castle JR, El Youssef J, Carroll JM, David LL, Roberts CT, Ward WK. A novel, stable, aqueous glucagon formulation using ferulic acid as an excipient. J Diabetes Sci Technol 2015; 9:17-23. [PMID: 25253164 PMCID: PMC4495527 DOI: 10.1177/1932296814552476] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Commercial glucagon is unstable due to aggregation and degradation. In closed-loop studies, it must be reconstituted frequently. For use in a portable pump for 3 days, a more stable preparation is required. At alkaline pH, curcumin inhibited glucagon aggregation. However, curcumin is not sufficiently stable for long-term use. Here, we evaluated ferulic acid, a stable breakdown product of curcumin, for its ability to stabilize glucagon. Ferulic acid-formulated glucagon (FAFG), composed of ferulic acid, glucagon, L-methionine, polysorbate-80, and human serum albumin in glycine buffer at pH 9, was aged for 7 days at 37°C. Glucagon aggregation was assessed by transmission electron microscopy (TEM) and degradation by high-performance liquid chromatography (HPLC). A cell-based protein kinase A (PKA) assay was used to assess in vitro bioactivity. Pharmacodynamics (PD) of unaged FAFG, 7-day aged FAFG, and unaged synthetic glucagon was determined in octreotide-treated swine. No fibrils were observed in TEM images of fresh or aged FAFG. Aged FAFG was 94% intact based on HPLC analysis and there was no loss of bioactivity. In the PD swine analysis, the rise over baseline of glucose with unaged FAFG, aged FAFG, and synthetic native glucagon (unmodified human sequence) was similar. After 7 days of aging at 37°C, an alkaline ferulic acid formulation of glucagon exhibited significantly less aggregation and degradation than that seen with native glucagon and was bioactive in vitro and in vivo. Thus, this formulation may be stable for 3-7 days in a portable pump for bihormonal closed-loop treatment of T1D.
Collapse
|
107
|
Abstract
Prevention of diabetic complications is mainly obtained through optimal control of blood glucose levels. With hypoglycemic drugs like beta-cell stimulating drugs and especially insulin, the limit to treatment is represented by hypoglycemia, a life-threatening occurrence that is dangerous itself and can induce fear of other episodes. Glucagon, injected subcutaneously (SC) or intramuscularly (IM), is the treatment of choice for severe hypoglycemia outside of the hospital setting. However, due to practical aspects such as preparation of solutions for administration and injection by untrained persons, there are obstacles to its routine use. This review focuses on the current status of alternative routes of administration of peptide hormones, and in particular the intranasal (IN) route of glucagon, as a promising approach for the treatment of severe hypoglycemia.
Collapse
|
108
|
O'Harte FPM, Franklin ZJ, Irwin N. Two novel glucagon receptor antagonists prove effective therapeutic agents in high-fat-fed and obese diabetic mice. Diabetes Obes Metab 2014; 16:1214-22. [PMID: 25060150 DOI: 10.1111/dom.12360] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2014] [Revised: 07/03/2014] [Accepted: 07/19/2014] [Indexed: 11/30/2022]
Abstract
AIMS To examine the effect of two novel, enzymatically stable, glucagon receptor peptide antagonists, on metabolic control in two mouse models of obesity/diabetes. METHOD The effects of twice daily i.p. administration of desHis(1)Pro(4)Glu(9)-glucagon or desHis(1)Pro(4)Glu(9)Lys(12)FA-glucagon for 10 days on metabolic control in high-fat-fed (HFF; 45% fat) and obese diabetic (ob/ob) mice were compared with saline-treated controls. RESULTS Neither analogue altered body weight or food intake in either model over 10 days; however, treatment with each peptide restored non-fasting blood glucose towards normal control values in HFF mice. Basal glucose was also reduced (p < 0.01) in desHis(1)Pro(4)Glu(9)Lys(12)FA-glucagon treated ob/ob mice by day 10, coinciding with increases (p < 0.001) in circulating insulin. At the end of the treatment period, both analogues significantly (p < 0.05-0.01) improved oral and i.p. glucose tolerance (p < 0.05) and peripheral insulin sensitivity, increased pancreatic insulin and glucagon content (p < 0.05-0.01) and decreased (p < 0.05) cholesterol levels in HFF mice. Similarly beneficial metabolic effects on oral glucose tolerance (p < 0.01) and pancreatic insulin content (p < 0.05) were observed in ob/ob mice, especially after desHis(1)Pro(4)Glu(9)Lys(12)FA-glucagon treatment. No significant differences in circulating triglycerides or aspects of indirect calorimetry were noted between peptide treatment groups and respective control HFF and ob/ob mice. Finally, glucagon-mediated elevations of glucose and insulin were significantly (p < 0.05-0.01) annulled after 10 days of desHis(1)Pro(4)Glu(9)-glucagon or desHis(1)Pro(4)Glu(9)Lys(12)FA-glucagon treatment in both animal models. CONCLUSION These data indicate that peptide-based glucagon receptor antagonists can reverse aspects of genetically and dietary-induced obesity-related diabetes.
Collapse
|
109
|
Cegla J, Troke RC, Jones B, Tharakan G, Kenkre J, McCullough KA, Lim CT, Parvizi N, Hussein M, Chambers ES, Minnion J, Cuenco J, Ghatei MA, Meeran K, Tan TM, Bloom SR. Coinfusion of low-dose GLP-1 and glucagon in man results in a reduction in food intake. Diabetes 2014; 63:3711-20. [PMID: 24939425 DOI: 10.2337/db14-0242] [Citation(s) in RCA: 111] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Obesity is a growing epidemic, and current medical therapies have proven inadequate. Endogenous satiety hormones provide an attractive target for the development of drugs that aim to cause effective weight loss with minimal side effects. Both glucagon and GLP-1 reduce appetite and cause weight loss. Additionally, glucagon increases energy expenditure. We hypothesized that the combination of both peptides, administered at doses that are individually subanorectic, would reduce appetite, while GLP-1 would protect against the hyperglycemic effect of glucagon. In this double-blind crossover study, subanorectic doses of each peptide alone, both peptides in combination, or placebo was infused into 13 human volunteers for 120 min. An ad libitum meal was provided after 90 min, and calorie intake determined. Resting energy expenditure was measured by indirect calorimetry at baseline and during infusion. Glucagon or GLP-1, given individually at subanorectic doses, did not significantly reduce food intake. Coinfusion at the same doses led to a significant reduction in food intake of 13%. Furthermore, the addition of GLP-1 protected against glucagon-induced hyperglycemia, and an increase in energy expenditure of 53 kcal/day was seen on coinfusion. These observations support the concept of GLP-1 and glucagon dual agonism as a possible treatment for obesity and diabetes.
Collapse
|
110
|
Robertson RP, Raymond RH, Lee DS, Calle RA, Ghosh A, Savage PJ, Shankar SS, Vassileva MT, Weir GC, Fryburg DA. Arginine is preferred to glucagon for stimulation testing of β-cell function. Am J Physiol Endocrinol Metab 2014; 307:E720-7. [PMID: 25159323 PMCID: PMC4200308 DOI: 10.1152/ajpendo.00149.2014] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A key aspect of research into the prevention and treatment of type 2 diabetes is the availability of reproducible clinical research methodology to assess β-cell function. One commonly used method employs nonglycemic secretagogues like arginine (arg) or glucagon (glgn). This study was designed to quantify the insulin response to arg and glgn and determine test repeatability and tolerability. Obese overnight-fasted subjects with normal glucose tolerance were studied on 4 separate days: twice using arg (5 g iv) and twice with glgn (1 mg iv). Pre- and postinfusion samples for plasma glucose, insulin, and C-peptide were acquired. Arg and glgn challenges were repeated in the last 10 min of a 60-min glucose (900 mg/min) infusion. Insulin and C-peptide secretory responses were estimated under baseline fasting glucose conditions (AIRarg and AIRglgn) and hyperglycemic (AIRargMAX AIRglgnMAX) states. Relative repeatability was estimated by intraclass correlation coefficient (ICC). Twenty-three (12 men and 11 women) subjects were studied (age: 42.4 ± 8.3 yr; BMI: 31.4 ± 2.8 kg/m²). Geometric means (95% CI) for baseline-adjusted values AIRarg and AIRglgn were 84 (75-95) and 102 (90-115) μU/ml, respectively. After the glucose infusion, AIRargMAX and AIRglgnMAX were 395 (335-466) and 483 (355-658) μU/ml, respectively. ICC values were >0.90 for AIRarg andAIRargMAX. Glucagon ICCs were 0.83, 0.34, and 0.36, respectively, although the exclusion of one outlier increased the latter two values (to 0.84 and 0.86). Both glgn and arg induced mild adverse events that were transient. Glucagon, but not arginine, induced moderate adverse events due to nausea. Taken together, arginine is preferred to glucagon for assessment of β-cell function.
Collapse
|
111
|
McShane LM, Franklin ZJ, O'Harte FPM, Irwin N. Ablation of glucagon receptor signaling by peptide-based glucagon antagonists improves glucose tolerance in high fat fed mice. Peptides 2014; 60:95-101. [PMID: 25148830 DOI: 10.1016/j.peptides.2014.08.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 08/06/2014] [Accepted: 08/06/2014] [Indexed: 01/21/2023]
Abstract
Modification to the structure of glucagon has provided a number of glucagon receptor antagonists with possible therapeutic application for diabetes. These novel peptide analogs include desHis(1)Pro(4)Glu(9)-glucagon and desHis(1)Pro(4)Glu(9)(Lys(30)PAL)-glucagon. This study has evaluated the metabolic benefits of once daily administration of desHis(1)Pro(4)Glu(9)-glucagon and desHis(1)Pro(4)Glu(9)(Lys(30)PAL)-glucagon in high fat (45%) fed mice for 15 days. Administration of desHis(1)Pro(4)Glu(9)-glucagon and desHis(1)Pro(4)Glu(9)(Lys(30)PAL)-glucagon had no significant effect on body weight, food intake or circulating glucose concentrations during the treatment period. However, both peptides significantly (P<0.05 to P<0.01) reduced circulating plasma insulin concentrations from day 6 onwards. Oral glucose tolerance and insulin sensitivity, as assessed by exogenous insulin administration, were significantly (P<0.01 to P<0.001) improved by both desHis(1)Pro(4)Glu(9)-glucagon and desHis(1)Pro(4)Glu(9)(Lys(30)PAL)-glucagon. These metabolic benefits were accompanied by significantly (P<0.01) increased pancreatic insulin stores. No significant differences in blood triacylglycerol or cholesterol levels were noted with desHis(1)Pro(4)Glu(9)-glucagon, however desHis(1)Pro(4)Glu(9)(Lys(30)PAL)-glucagon treatment significantly (P<0.01) increased HDL-cholesterol levels. Glucagon-mediated elevations of glucose and insulin were effectively (P<0.01 to P<0.001) annulled in both treatment groups on day 15. Interestingly, glucose levels during an intraperitoneal glucose tolerance test were not altered by either desHis(1)Pro(4)Glu(9)-glucagon or desHis(1)Pro(4)Glu(9)(Lys(30)PAL)-glucagon treatment. These data provide further evidence that glucagon antagonism could provide an effective means of treating T2DM.
Collapse
|
112
|
Shenoy S, Lankala S, Adigopula S. Management of calcium channel blocker overdoses. J Hosp Med 2014; 9:663-8. [PMID: 25066023 DOI: 10.1002/jhm.2241] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 07/01/2014] [Accepted: 07/08/2014] [Indexed: 11/09/2022]
Abstract
Calcium channel blockers (CCBs) are some of the most commonly used medications in clinical practice to treat hypertension, angina, cardiac arrhythmias, and some cases of heart failure. Recent data show that CCBs are the most common of the cardiovascular medications noted in intentional or unintentional overdoses.(1) Novel treatment approaches in the form of glucagon, high-dose insulin therapy, and intravenous lipid emulsion therapies have been tried and have been successful. However, the evidence for these are limited to case reports and case series. We take this opportunity to review the various treatment options in the management of CCB overdoses with a special focus on high-dose insulin therapy as the emerging choice for initial therapy in severe overdoses.
Collapse
|
113
|
Jacobs PG, El Youssef J, Castle J, Bakhtiani P, Branigan D, Breen M, Bauer D, Preiser N, Leonard G, Stonex T, Ward WK. Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies. IEEE Trans Biomed Eng 2014; 61:2569-81. [PMID: 24835122 DOI: 10.1109/tbme.2014.2323248] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Automated control of blood glucose in patients with type-1 diabetes has not yet been fully implemented. The aim of this study was to design and clinically evaluate a system that integrates a control algorithm with off-the-shelf subcutaneous sensors and pumps to automate the delivery of the hormones glucagon and insulin in response to continuous glucose sensor measurements. The automated component of the system runs an adaptive proportional derivative control algorithm which determines hormone delivery rates based on the sensed glucose measurements and the meal announcements by the patient. We provide details about the system design and the control algorithm, which incorporates both a fading memory proportional derivative controller (FMPD) and an adaptive system for estimating changing sensitivity to insulin based on a glucoregulatory model of insulin action. For an inpatient study carried out in eight subjects using Dexcom SEVEN PLUS sensors, prestudy HbA1c averaged 7.6, which translates to an estimated average glucose of 171 mg/dL. In contrast, during use of the automated system, after initial stabilization, glucose averaged 145 mg/dL and subjects were kept within the euglycemic range (between 70 and 180 mg/dL) for 73.1% of the time, indicating improved glycemic control. A further study on five additional subjects in which we used a newer and more reliable glucose sensor (Dexcom G4 PLATINUM) and made improvements to the insulin and glucagon pump communication system resulted in elimination of hypoglycemic events. For this G4 study, the system was able to maintain subjects' glucose levels within the near-euglycemic range for 71.6% of the study duration and the mean venous glucose level was 151 mg/dL.
Collapse
|
114
|
Ozawa S, Katsuta H, Suzuki K, Takahashi K, Tanaka T, Sumitani Y, Nishida S, Yoshimoto K, Ishida H. Estimated proinsulin processing activity of prohormone convertase (PC) 1/3 rather than PC2 is decreased in pancreatic β-cells of type 2 diabetic patients. Endocr J 2014; 61:607-14. [PMID: 24705588 DOI: 10.1507/endocrj.ej13-0506] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Type 2 diabetic (T2D) patients exhibit fasting relative hyperproinsulinemia owing to pancreatic β-cell dysfunction. To clarify the mechanism underlying this hyperproinsulinemic state, we evaluated the activities of the endopeptidases prohormone convertase (PC) 1/3 and PC2 in T2D patients. Fasting blood levels of intact proinsulin (IPI), total proinsulin (t-PI) and C-peptide were measured simultaneously, and intravenous glucagon loading was performed to investigate the dynamics of circulating proinsulin-related molecules released from pancreatic β-cells in 12 healthy volunteers and 18 T2D patients. Taking advantage of the 95% cross-reactivity between proinsulin and des-31,32-proinsulin (des-31,32-PI) with the human proinsulin radioimmunoassay kit used in this study, we estimated PC1/3 and PC2 activities using the following formulas: des-31,32-PI = (t-PI-IPI)/0.95; PC1/3 activity = des-31,32-PI/IPI; and PC2 activity = C-peptide/des-31,32-PI. C-peptide responses to glucagon were slightly lower among T2D patients. IPI and the IPI/C-peptide ratio were significantly higher in T2D patients (p<0.05 and p<0.01, respectively). There was no difference in des-31,32-PI levels or PC2 activity between the two groups. However, PC1/3 activity was significantly lower in T2D patients than in the control group (p<0.01). We propose that decreased activity of PC1/3 rather than PC2 in pancreatic β-cells is involved in the impaired proinsulin processing, resulting in elevated IPI levels in T2D patients.
Collapse
|
115
|
Grand-Guillaume-Perrenoud L, Registe-Rameau M, Castellsague-Perolini M. [The elderly diabetic patient. Hypoglycemia under control]. KRANKENPFLEGE. SOINS INFIRMIERS 2014; 107:52-77. [PMID: 25327128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
116
|
Bakhtiani PA, Zhao LM, El Youssef J, Castle JR, Ward WK. A review of artificial pancreas technologies with an emphasis on bi-hormonal therapy. Diabetes Obes Metab 2013; 15:1065-70. [PMID: 23602044 PMCID: PMC3766424 DOI: 10.1111/dom.12107] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2012] [Revised: 01/07/2013] [Accepted: 03/27/2013] [Indexed: 01/30/2023]
Abstract
Since the discovery of insulin, great progress has been made to improve the accuracy and safety of automated insulin delivery systems to help patients with type 1 diabetes achieve their treatment goals without causing hypoglycaemia. In recent years, bioengineering technology has greatly advanced diabetes management, with the development of blood glucose meters, continuous glucose monitors, insulin pumps and control systems for automatic delivery of one or more hormones. New insulin analogues have improved subcutaneous absorption characteristics, but do not completely eliminate the risk of hypoglycaemia. Insulin effect is counteracted by glucagon in non-diabetic individuals, while glucagon secretion in those with type 1 diabetes is impaired. The use of glucagon in the artificial pancreas is therefore a logical and feasible option for preventing and treating hypoglycaemia. However, commercially available glucagon is not stable in aqueous solution for long periods, forming potentially cytotoxic fibrils that aggregate quickly. Therefore, a more stable formulation of glucagon is needed for long-term use and storage in a bi-hormonal pump. In addition, a model of glucagon action in type 1 diabetes is lacking, further limiting the inclusion of glucagon into systems employing model-assisted control. As a result, although several investigators have been working to help develop bi-hormonal systems for patients with type 1 diabetes, most continue to utilize single hormone systems employing only insulin. This article seeks to focus on the attributes of glucagon and its use in bi-hormonal systems.
Collapse
|
117
|
Lv D, Breton MD, Farhy LS. Pharmacokinetics modeling of exogenous glucagon in type 1 diabetes mellitus patients. Diabetes Technol Ther 2013; 15:935-41. [PMID: 23978267 PMCID: PMC3818836 DOI: 10.1089/dia.2013.0150] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Insulin-induced hypoglycemia is as a critical barrier in the treatment of type 1 diabetes mellitus patients and may lead to unconsciousness, brain damage, or even death. Clinically, glucagon is used as a rescue drug to treat severe hypoglycemic episodes. More recently, in a bihormonal closed-loop glucose control, glucagon has been used subcutaneously along with insulin for protection against hypoglycemia. In this context, small doses of glucagon are frequently administered. The efficacy and safety of such systems, however, require precise information on the pharmacokinetics of the glucagon transport from the administrative site to the circulation, which is currently lacking. The goal of this work is to address this need by developing and validating a mathematical model of exogenous glucagon transport to the plasma. MATERIALS AND METHODS Eight pharmacokinetic models with various levels of complexity were fitted to nine clinical datasets. An optimal model was chosen in two consecutive steps. At Step 1, all models were screened for parameter identifiability (discarding the unidentifiable candidates). At Step 2, the remaining models are compared based on Bayesian information criterion. RESULTS At Step 1, two models were removed for higher parameter fractional SDs. Another three were discarded for location of their optimal parameters on the parameter search boundaries. At Step 2, an optimal model was selected based on the Bayesian information criterion. It has a simple linear structure, assuming that glucagon is injected into one compartment, from where it enters a pool for a slower release into a third, plasma compartment. In the first and third compartments, glucagon is cleared at a rate proportional to its concentration. CONCLUSIONS A linear kinetic model of glucagon intervention has been developed and validated. It is expected to provide guidance for glucagon delivery and the construction of preclinical simulation testing platforms.
Collapse
|
118
|
Haidar A, Duval C, Legault L, Rabasa-Lhoret R. Pharmacokinetics of insulin aspart and glucagon in type 1 diabetes during closed-loop operation. J Diabetes Sci Technol 2013; 7:1507-12. [PMID: 24351176 PMCID: PMC3876328 DOI: 10.1177/193229681300700610] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND We assessed the pharmacokinetics of subcutaneous insulin aspart and glucagon during closed-loop operation and their relationship with body composition variables. METHODS We retrospectively analyzed data collected from closed-loop experiments in 15 type 1 diabetes patients (age 47.1 ± 12.3 years, body mass index 25.9 ± 4.6 kg/m², glycated hemoglobin 7.9% ± 0.7%). Patients received an evening meal accompanied with prandial insulin bolus and stayed in the clinical facility until the next morning. Glucose levels were regulated by dual-hormone closed-loop delivery. Insulin and glucagon were delivered using two subcutaneous infusion pumps installed on the abdominal wall. Plasma insulin and glucagon were measured every 10-30 min. Percentage of body fat, percentage of fat in the abdominal area, and mass of abdominal fat were measured by dual X-ray absorptiometry. RESULTS A pharmacokinetic model estimated time-to-peak plasma concentrations [t(max) insulin 51 (19) min, t(max) glucagon 19 (4) min, mean (standard deviation)], metabolic clearance rate [MCR insulin 0.019 (0.015-0.026) liter/kg/min, MCR glucagon 0.012 (0.010-0.014) liter/kg/min, median (interquartile range)], and the background plasma concentrations [I(b) insulin 10.2 (6.3-15.2) mU/liter, I(b) glucagon 50 (45-56) pg/ml, median (interquartile range)]. t(max) correlated positively between insulin and glucagon (r = 0.7; p = .007) while MCR correlated negatively (r = -0.7; p = .015). In this small sample size, t(max), MCR, and I(b) of insulin and glucagon did not correlate with percentage of body fat, percentage of fat in the abdominal area, or total mass of abdominal fat. CONCLUSIONS Insulin and glucagon pharmacokinetics might be related during closed-loop operation. Our data suggest that slower absorption of insulin is associated with slower absorption of glucagon. Body composition does not seem to influence insulin and glucagon pharmacokinetics.
Collapse
|
119
|
McCall AL, Farhy LS. Treating type 1 diabetes: from strategies for insulin delivery to dual hormonal control. MINERVA ENDOCRINOL 2013; 38:145-63. [PMID: 23732369 PMCID: PMC4220674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Type 1 diabetes is a disorder where slow destruction of pancreatic β-cells occurs through autoimmune mechanisms. The result is a progressive and ultimately complete lack of endogenous insulin. Due to β-cell lack, secondary abnormalities in glucagon and likely in incretins occur. These multiple hormonal abnormalities cause metabolic instability and extreme glycemic variability, which is the primary phenotype. As the disease progresses patients often develop hypoglycemia unawareness and defects in their counterregulatory defenses. Intensive insulin therapy may thus lead to 3-fold excess of severe hypoglycemia and severely hinder the effective and safe control of hyperglycemia. The main goal of the therapy for type 1 diabetes has long been physiological mimicry of normal insulin secretion based on monitoring which requires considerable effort and understanding of the underlying physiology. Attainment of this goal is challenged by the nature of the disease and our current lack of means to fully repair the abnormal endocrine pancreas interactive functions. As a result, various insulin preparations have been developed to partially compensate for the inability to deliver timely exogenous insulin directly to the portal/intrapancreatic circulation. It remains an ongoing task to identify the ideal routes and regimens of their delivery and potentially that of other hormones to restore the deficient and disordered hormonal environment of the pancreas to achieve a near normal metabolic state. Several recent technological advances help addressing these goals, including the rapid progress in insulin pumps, continuous glucose sensors, and ultimately the artificial pancreas closed-loop technology and the recent start of dual-hormone therapies.
Collapse
|
120
|
Longuet C, Robledo AM, Dean ED, Dai C, Ali S, McGuinness I, de Chavez V, Vuguin PM, Charron MJ, Powers AC, Drucker DJ. Liver-specific disruption of the murine glucagon receptor produces α-cell hyperplasia: evidence for a circulating α-cell growth factor. Diabetes 2013; 62:1196-205. [PMID: 23160527 PMCID: PMC3609565 DOI: 10.2337/db11-1605] [Citation(s) in RCA: 138] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Glucagon is a critical regulator of glucose homeostasis; however, mechanisms regulating glucagon action and α-cell function and number are incompletely understood. To elucidate the role of the hepatic glucagon receptor (Gcgr) in glucagon action, we generated mice with hepatocyte-specific deletion of the glucagon receptor. Gcgr(Hep)(-/-) mice exhibited reductions in fasting blood glucose and improvements in insulin sensitivity and glucose tolerance compared with wild-type controls, similar in magnitude to changes observed in Gcgr(-/-) mice. Despite preservation of islet Gcgr signaling, Gcgr(Hep)(-/-) mice developed hyperglucagonemia and α-cell hyperplasia. To investigate mechanisms by which signaling through the Gcgr regulates α-cell mass, wild-type islets were transplanted into Gcgr(-/-) or Gcgr(Hep)(-/-) mice. Wild-type islets beneath the renal capsule of Gcgr(-/-) or Gcgr(Hep)(-/-) mice exhibited an increased rate of α-cell proliferation and expansion of α-cell area, consistent with changes exhibited by endogenous α-cells in Gcgr(-/-) and Gcgr(Hep)(-/-) pancreata. These results suggest that a circulating factor generated after disruption of hepatic Gcgr signaling can increase α-cell proliferation independent of direct pancreatic input. Identification of novel factors regulating α-cell proliferation and mass may facilitate the generation and expansion of α-cells for transdifferentiation into β-cells and the treatment of diabetes.
Collapse
|
121
|
Tan TM, Field BC, McCullough KA, Troke RC, Chambers ES, Salem V, Gonzalez Maffe J, Baynes KC, De Silva A, Viardot A, Alsafi A, Frost GS, Ghatei MA, Bloom SR. Coadministration of glucagon-like peptide-1 during glucagon infusion in humans results in increased energy expenditure and amelioration of hyperglycemia. Diabetes 2013; 62:1131-8. [PMID: 23248172 PMCID: PMC3609580 DOI: 10.2337/db12-0797] [Citation(s) in RCA: 171] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Glucagon and glucagon-like peptide (GLP)-1 are the primary products of proglucagon processing from the pancreas and gut, respectively. Giving dual agonists with glucagon and GLP-1 activity to diabetic, obese mice causes enhanced weight loss and improves glucose tolerance by reduction of food intake and by increase in energy expenditure (EE). We aimed to observe the effect of a combination of glucagon and GLP-1 on resting EE and glycemia in healthy human volunteers. In a randomized, double-blinded crossover study, 10 overweight or obese volunteers without diabetes received placebo infusion, GLP-1 alone, glucagon alone, and GLP-1 plus glucagon simultaneously. Resting EE--measured using indirect calorimetry--was not affected by GLP-1 infusion but rose significantly with glucagon alone and to a similar degree with glucagon and GLP-1 together. Glucagon infusion was accompanied by a rise in plasma glucose levels, but addition of GLP-1 to glucagon rapidly reduced this excursion, due to a synergistic insulinotropic effect. The data indicate that drugs with glucagon and GLP-1 agonist activity may represent a useful treatment for type 2 diabetes and obesity. Long-term studies are required to demonstrate that this combination will reduce weight and improve glycemia in patients.
Collapse
|
122
|
Kuznetsova LA, Plesneva SA, Sharova TS, Pertseva MN, Shpakov AO. [Regulation of adenylyl cyclase signaling system by insulin, biogenic amines, and glucagon at their separate and combined action in the muscle membranes of the mollusc Anodonta cygnea]. ZHURNAL EVOLIUTSIONNOI BIOKHIMII I FIZIOLOGII 2013; 49:111-117. [PMID: 23789396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In smooth muscles of mollusc Anodonta cygnea, hormones produce regulatory effects on the adenylyl cyclase (AC) signaling system via receptors of the serpentine (biogenic amine, isoproterenol, glucagon) and of tyrosine kinase (insulin) types. Intracellular mechanisms of their action are interconnected. Use of hormones, their antagonists, and pertussis toxin at the combined action of insulin and biogenic amines or of glucagon on the AC activity allows revealing possible intersection points in mechanisms of their action. The combined effect of insulin and serotonin or of glucagon leads to a decrease of stimulation of AC by these hormones, whereas at action of insulin and isoproterenol the AC-stimulatory effect of insulin is blocked, while the AC-inhibitory effect of isoproterenol is preserved both in the presence and in the absence of the non-hydrolyzed GTP analog - guanylylimidodiphosphate (GppNHp). Specific blocking of the AC-stimulatory serotonin effect by cyproheptadine - an antagonist of serotonin receptors - did not affect stimulation of AC by insulin. Beta-adrenoblockers (propranolol and alprenolol) interfered with inhibition of the AC activity by isoproterenol, but did not change the AC stimulation by insulin. Pertussis toxin blocked the AC-inhibitory effect of isoproterenol and attenuated the AC-stimulatory effect of insulin. Thus, in muscles of the mollusc Anodonta cygnea there have been revealed negative interrelations between the AC system, which are realized at the combined effect of insulin and serotonin or of glucagon, probably at the level of receptor of the serpentine type (serotonin, glucagon), while at action of insulin and isoproterenol - at the level of interaction of G1 protein and AC.
Collapse
|
123
|
Fukui T, Oono K, Hara N, Yamamoto T, Nagashima M, Naito H, Hirano T. Increment of C-peptide after glucagon injection determines the progressive nature of Japanese type 2 diabetes: a long-term follow-up study. Endocr J 2013; 60:715-24. [PMID: 23386398 DOI: 10.1507/endocrj.ej12-0357] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Type 2 diabetes (T2D) is characterized by a steady worsening of β-cell dysfunction as the disease progresses. The objective of this study was to estimate the decline of insulin secretion in Japanese type 2 diabetic patients (T2D-patients) by glucagon injection over an observation period of more than 10 years. Thirty-three T2D-patients were followed for 10.4 ± 1.4 years. Fasting C-peptide immunoreactivity (FCPR), the 6 min value of CPR after glucagon injection (6MCPR), and the increment of CPR (ΔCPR) were measured at baseline and follow-up. FCPR, 6MCPR, ΔCPR were significantly lower at follow-up than at baseline (p<0.05, p<0.005, and p<0.0005, respectively). The annual change of ΔCPR was significantly (p<0.05) greater than the annual change of FCPR (-0.062 ± 0.076 ng/mL/year and -0.025 ± 0.067 ng/mL/year, respectively). In contrast, CPR-index (an index of β-cell function) and SUIT-index (secretory units of islets in transplantation) calculated based on fasting blood samples were unaltered. The annual changes of FCPR, 6MCPR, and ΔCPR were negatively correlated with the FCPR, 6MCPR, and ΔCPR values at baseline, respectively. Duration of diabetes, BMI, diabetic retinopathy, and secondary sulfonylurea failure at baseline were not correlated with the annual changes of FCPR, 6MCPR, and ΔCPR. In conclusion, our longitudinal observations suggest that β-cell function progressively declines in Japanese T2D-patients. The annual declines of ΔCPR were more prominent than the annual declines of FCPR. ΔCPR after glucagon injection may be more useful for estimating individual longitudinal insulin secretion than fasting blood samples.
Collapse
|
124
|
Neylon OM, Moran MM, Pellicano A, Nightingale M, O'Connell MA. Successful subcutaneous glucagon use for persistent hypoglycaemia in congenital hyperinsulinism. J Pediatr Endocrinol Metab 2013; 26:1157-61. [PMID: 23813352 DOI: 10.1515/jpem-2013-0115] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2013] [Accepted: 06/03/2013] [Indexed: 11/15/2022]
Abstract
Abstract Congenital hyperinsulinism (CHI) results from inappropriate excessive insulin secretion by the beta cells in the pancreas. A wide clinical spectrum of disease exists and a genetic diagnosis is now possible for approximately 50% of affected children. We describe a patient with atypical diffuse CHI caused by mosaic ABCC8 mutation inheritance, unmasked by paternal uniparental disomy. Hypoglycaemia persisted despite two subtotal pancreatectomies and trials of diazoxide and nifedipine were unsuccessful. Octreotide resulted in anaphylaxis, precluding its use. Continuous subcutaneous glucagon infusion was successful in restoring normoglycaemia and attenuating weight gain, with concomitant improvement of developmental milestones. No adverse effects have been encountered after >12 months of therapy. Administration problems (e.g., line crystallisation) may complicate continuous glucagon therapy; hence a practical description of infusion constitution is included. We recommend consideration of continuous subcutaneous glucagon infusion as a therapeutic option for persistent refractory hypoglycaemia in CHI.
Collapse
|
125
|
Jackson MA, Caputo N, Castle JR, David LL, Roberts CT, Ward WK. Stable liquid glucagon formulations for rescue treatment and bi-hormonal closed-loop pancreas. Curr Diab Rep 2012; 12:705-10. [PMID: 22972416 PMCID: PMC3970213 DOI: 10.1007/s11892-012-0320-5] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Small doses of glucagon given subcutaneously in the research setting by an automated system prevent most cases of hypoglycemia in persons with diabetes. However, glucagon is very unstable and cannot be kept in a portable pump. Glucagon rapidly forms amyloid fibrils, even within the first day after reconstitution. Aggregation eventually leads to insoluble gels, which occlude pump catheters. Fibrillation occurs rapidly at acid pH, but is absent or minimal at alkaline pH values of ~10. Glucagon also degrades over time; this problem is greater at alkaline pH. Several studies suggest that its primary degradative pathway is deamidation, which results in a conversion of asparagine to aspartic acid. A cell-based assay for glucagon bioactivity that assesses glucagon receptor (GluR) activation can screen promising glucagon formulations. However, mammalian hepatocytes are usually problematic as they can lose GluR expression during culture. Assays for cyclic AMP (cAMP) or its downstream effector, protein kinase A (PKA), in engineered cell systems, are more reliable and suitable for inexpensive, high-throughput assessment of bioactivity.
Collapse
|