1
|
Madhvapathy SR, Cho S, Gessaroli E, Forte E, Xiong Y, Gallon L, Rogers JA. Implantable bioelectronics and wearable sensors for kidney health and disease. Nat Rev Nephrol 2025:10.1038/s41581-025-00961-2. [PMID: 40301646 DOI: 10.1038/s41581-025-00961-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/27/2025] [Indexed: 05/01/2025]
Abstract
Established clinical practices for monitoring kidney health and disease - including biopsy and serum biomarker analysis - suffer from practical limitations in monitoring frequency and lack adequate sensitivity for early disease detection. Engineering advances in biosensors have led to the development of wearable and implantable systems for monitoring of kidney health. Non-invasive microfluidic systems have demonstrated utility in the detection of kidney-relevant biomarkers, such as creatinine, urea and electrolytes in peripheral body fluids such as sweat, interstitial fluid, tears and saliva. Implantable systems may aid the identification of early transplant rejection through analysis of organ temperature and perfusion, and enable real-time assessment of inflammation through the use of thermal sensors. These technologies enable continuous, real-time monitoring of kidney health, offering complementary information to standard clinical procedures to alert physicians of changes in kidney health for early intervention. In this Review, we explore devices for monitoring renal biomarkers in peripheral biofluids and discuss developments in implantable sensors for the direct measurement of the local, biophysical properties of kidney tissue. We also describe potential clinical applications, including monitoring of chronic kidney disease, acute kidney injury and allograft health.
Collapse
Affiliation(s)
- Surabhi R Madhvapathy
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL, USA
| | - Soongwon Cho
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
| | - Elisa Gessaroli
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum - University of Bologna, Bologna, Italy
- Department of Medicine, Division of Nephrology, University of Illinois College of Medicine, Chicago, IL, USA
| | - Eleonora Forte
- Department of Medicine, Division of Nephrology, University of Illinois College of Medicine, Chicago, IL, USA
| | - Yirui Xiong
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL, USA
| | - Lorenzo Gallon
- Department of Medicine, Division of Nephrology, University of Illinois College of Medicine, Chicago, IL, USA.
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA.
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL, USA.
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
- Department of Neurological Surgery, Northwestern University, Chicago, IL, USA.
| |
Collapse
|
2
|
Sung D, Han S, Kim S, Kang H, Jekal B, Kim G, Kim J, Hong M, Moon G, Kim S, Lee Y, Hwang SW, Jeong H, Ryu YS, Kim S, Koo J. Electrophoretic digital colorimetry integrated with electrochemical sweat sensor. SCIENCE ADVANCES 2025; 11:eadu2142. [PMID: 40153516 PMCID: PMC11952109 DOI: 10.1126/sciadv.adu2142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Accepted: 02/24/2025] [Indexed: 03/30/2025]
Abstract
Recent advancements in wearable sweat sensors, which use standardized electrochemical and colorimetric mechanisms, offer holistic representation of health status for users. However, the constraints of standardized sweat sensors present ongoing challenges to realization of personalized health management. This study presents an electrocolorimetric (EC) platform that enables the reversible and multiple-time use of colorimetric data visualization using electrophoretic display (EPD). This platform represents the application of low-power EPD in epidermal sweat sensor, evaluated through CIELAB-based methodology which is the first systematic evaluation tool of wearable display performance. Moreover, our platform has been demonstrated in human exercise trials for its ability to detect the lactate threshold (LT). This digital colorimetric system has the potential to play a pivotal role by integrating various health monitoring biomarkers. While providing real-time, continuous, and adjustable range information with high sensitivity, this platform validates its extensive probability as a next-generation wearable epidermal sensor.
Collapse
Affiliation(s)
- Daeun Sung
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Seunghun Han
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Sumin Kim
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Heeseok Kang
- KU-KIST Graduate School of Converging Science and Technology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Bon Jekal
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Giheon Kim
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Jaewon Kim
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Minki Hong
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Gyounghwan Moon
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Sungeun Kim
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Yerim Lee
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| | - Suk-Won Hwang
- KU-KIST Graduate School of Converging Science and Technology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
- Department of Integrative Energy Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Hyoyoung Jeong
- Department of Electrical and Computer Engineering, University of California, Davis, CA 95616, USA
| | - Yong-Sang Ryu
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Department of Micro/Nano Systems, Korea University, Seoul 02841, Republic of Korea
- BK21 Four Institute of Precision Public Health, Korea University, Seoul, Republic of Korea
| | - Sungbong Kim
- Department of Chemistry, Korea Military Academy, Seoul 01805, Republic of Korea
| | - Jahyun Koo
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
| |
Collapse
|
3
|
Ursem RFR, Steijlen A, Parrilla M, Bastemeijer J, Bossche A, De Wael K. Worth your sweat: wearable microfluidic flow rate sensors for meaningful sweat analytics. LAB ON A CHIP 2025; 25:1296-1315. [PMID: 39878525 PMCID: PMC11776456 DOI: 10.1039/d4lc00927d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Accepted: 01/16/2025] [Indexed: 01/31/2025]
Abstract
Wearable microfluidic sweat sensors could play a major role in the future of monitoring health and wellbeing. Sweat contains biomarkers to monitor health and hydration status, and it can provide information on drug intake, making it an interesting non-invasive alternative to blood. However, sweat is not created in excess, and this requires smart sweat collection strategies to handle small volumes. Microfluidic solutions are commonly employed which use capillary action or evaporation to drive flow. In current literature about sweat analytics, the emphasis lies predominantly on developing the sensors for measuring the composition of sweat. Yet, solely measuring sweat composition does not suffice, because the composition varies due to inter- and intra-individual differences in sweat rate. The measurement of sweat rate is thus crucial for enabling a reliable interpretation and standardisation of this data. Recently, more wearable sweat sensors, also integrating a means of measuring flow, have been developed. This manuscript reviews state-of-the-art sweat collection strategies and flow rate measuring techniques. Generally, flow rate measurements are performed by impedimetric or capacitive methods. However, these techniques can be impaired due to limited lifetime and signal interference from changing ionic contents in sweat. Discrete measurement techniques, such as impedance measurements of an advancing fluid front with interdigitated electrodes, calorimetric and colorimetric techniques can be very reliable, because they selectively measure flow. However, one should take the available size, intended application and compatibility with other sensors into account. Overall, accurate flow rate sensors integrated in reliable microfluidic sweat sensor platforms will enable the standardisation of sweat measurements to unlock the potential of sweat analytics in advancing physiological research, personalized diagnostics and treatment of diseases.
Collapse
Affiliation(s)
- R F R Ursem
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
| | - A Steijlen
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - M Parrilla
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - J Bastemeijer
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
| | - A Bossche
- Electronic Instrumentation, Department of Microelectronics, Delft University of Technology, Mekelweg 4, 2628 CD Delft, The Netherlands.
| | - K De Wael
- Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| |
Collapse
|
4
|
Zargartalebi H, Mirzaie S, GhavamiNejad A, Ahmed SU, Esmaeili F, Geraili A, Flynn CD, Chang D, Das J, Abdrabou A, Sargent EH, Kelley SO. Active-reset protein sensors enable continuous in vivo monitoring of inflammation. Science 2024; 386:1146-1153. [PMID: 39636994 DOI: 10.1126/science.adn2600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 06/11/2024] [Accepted: 10/08/2024] [Indexed: 12/07/2024]
Abstract
Continuous measurement of proteins in vivo is important for real-time disease management and prevention. Implantable sensors for monitoring small molecules such as glucose have been available for more than a decade. However, analysis of proteins remains an unmet need because the lower physiological levels require that sensors have high affinities, which are linked to long complexation half-lives (t1/2 ~20 hours) and slow equilibration when concentrations decrease. We report active-reset sensors by use of high-frequency oscillations to accelerate dissociation, which enables regeneration of the unbound form of the sensor within 1 minute. When implemented within implanted devices, these sensors allow for real-time, in vivo monitoring of proteins within interstitial fluid. Active-reset protein sensors track biomarker levels on a physiological timescale for inflammation monitoring in living animals.
Collapse
Affiliation(s)
- H Zargartalebi
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
- Department of Chemistry, Weinberg College of Arts and Sciences, Northwestern University, Evanston, IL, USA
- Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
| | - S Mirzaie
- Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
| | - A GhavamiNejad
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
| | - S U Ahmed
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
- Robert H. Laurie Comprehensive Cancer Center, Northwestern University, Chicago, IL, USA
| | - F Esmaeili
- Department of Chemistry, Weinberg College of Arts and Sciences, Northwestern University, Evanston, IL, USA
- Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
| | - A Geraili
- Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
| | - C D Flynn
- Department of Chemistry, Weinberg College of Arts and Sciences, Northwestern University, Evanston, IL, USA
| | - D Chang
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
| | - J Das
- Department of Chemistry, Weinberg College of Arts and Sciences, Northwestern University, Evanston, IL, USA
| | - A Abdrabou
- Robert H. Laurie Comprehensive Cancer Center, Northwestern University, Chicago, IL, USA
- Chan Zuckerberg Biohub Chicago, Chicago, IL, USA
| | - E H Sargent
- Department of Chemistry, Weinberg College of Arts and Sciences, Northwestern University, Evanston, IL, USA
- Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL, USA
| | - S O Kelley
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
- Department of Chemistry, Weinberg College of Arts and Sciences, Northwestern University, Evanston, IL, USA
- Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
- Robert H. Laurie Comprehensive Cancer Center, Northwestern University, Chicago, IL, USA
- Chan Zuckerberg Biohub Chicago, Chicago, IL, USA
| |
Collapse
|
5
|
Zhang Y, Zheng XT, Zhang X, Pan J, Thean AVY. Hybrid Integration of Wearable Devices for Physiological Monitoring. Chem Rev 2024; 124:10386-10434. [PMID: 39189683 DOI: 10.1021/acs.chemrev.3c00471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
Wearable devices can provide timely, user-friendly, non- or minimally invasive, and continuous monitoring of human health. Recently, multidisciplinary scientific communities have made significant progress regarding fully integrated wearable devices such as sweat wearable sensors, saliva sensors, and wound sensors. However, the translation of these wearables into markets has been slow due to several reasons associated with the poor system-level performance of integrated wearables. The wearability consideration for wearable devices compromises many properties of the wearables. Besides, the limited power capacity of wearables hinders continuous monitoring for extended duration. Furthermore, peak-power operations for intensive computations can quickly create thermal issues in the compact form factor that interfere with wearability and sensor operations. Moreover, wearable devices are constantly subjected to environmental, mechanical, chemical, and electrical interferences and variables that can invalidate the collected data. This generates the need for sophisticated data analytics to contextually identify, include, and exclude data points per multisensor fusion to enable accurate data interpretation. This review synthesizes the challenges surrounding the wearable device integration from three aspects in terms of hardware, energy, and data, focuses on a discussion about hybrid integration of wearable devices, and seeks to provide comprehensive guidance for designing fully functional and stable wearable devices.
Collapse
Affiliation(s)
- Yu Zhang
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117576, Singapore
| | - Xin Ting Zheng
- Institute of Materials Research and Engineering (IMRE), Agency for Science Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Singapore
| | - Xiangyu Zhang
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117576, Singapore
| | - Jieming Pan
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117576, Singapore
| | - Aaron Voon-Yew Thean
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117576, Singapore
| |
Collapse
|
6
|
Ma J, Li H, Anwer S, Umer W, Antwi-Afari MF, Xiao EB. Evaluation of sweat-based biomarkers using wearable biosensors for monitoring stress and fatigue: a systematic review. INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS 2024; 30:677-703. [PMID: 38581242 DOI: 10.1080/10803548.2024.2330242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2024]
Abstract
Objectives. This systematic review aims to report the evaluation of wearable biosensors for the real-time measurement of stress and fatigue using sweat biomarkers. Methods. A thorough search of the literature was carried out in databases such as PubMed, Web of Science and IEEE. A three-step approach for selecting research articles was developed and implemented. Results. Based on a systematic search, a total of 17 articles were included in this review. Lactate, cortisol, glucose and electrolytes were identified as sweat biomarkers. Sweat-based biomarkers are frequently monitored in real time using potentiometric and amperometric biosensors. Wearable biosensors such as an epidermal patch or a sweatband have been widely validated in scientific literature. Conclusions. Sweat is an important biofluid for monitoring general health, including stress and fatigue. It is becoming increasingly common to use biosensors that can measure a wide range of sweat biomarkers to detect fatigue during high-intensity work. Even though wearable biosensors have been validated for monitoring various sweat biomarkers, such biomarkers can only be used to assess stress and fatigue indirectly. In general, this study may serve as a driving force for academics and practitioners to broaden the use of wearable biosensors for the real-time assessment of stress and fatigue.
Collapse
Affiliation(s)
- Jie Ma
- Department of Building and Real Estate, Hong Kong Polytechnic University, People's Republic of China
| | - Heng Li
- Department of Building and Real Estate, Hong Kong Polytechnic University, People's Republic of China
| | - Shahnawaz Anwer
- Department of Building and Real Estate, Hong Kong Polytechnic University, People's Republic of China
| | - Waleed Umer
- Department of Mechanical and Construction Engineering, Northumbria University, UK
| | | | - Eric Bo Xiao
- Department of Building and Real Estate, Hong Kong Polytechnic University, People's Republic of China
| |
Collapse
|
7
|
Jiang Z, Lee YS, Wang Y, John H, Fang L, Tang Y. Advancements in Flexible Sensors for Monitoring Body Movements during Sleep: A Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:5091. [PMID: 39204787 PMCID: PMC11359190 DOI: 10.3390/s24165091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Revised: 08/01/2024] [Accepted: 08/02/2024] [Indexed: 09/04/2024]
Abstract
Sleep plays a role in maintaining our physical well-being. However, sleep-related issues impact millions of people globally. Accurate monitoring of sleep is vital for identifying and addressing these problems. While traditional methods like polysomnography (PSG) are commonly used in settings, they may not fully capture natural sleep patterns at home. Moreover, PSG equipment can disrupt sleep quality. In recent years, there has been growing interest in the use of sensors for sleep monitoring. These lightweight sensors can be easily integrated into textiles or wearable devices using technology. The flexible sensors can be designed for skin contact to offer continuous monitoring without being obtrusive in a home environment. This review presents an overview of the advancements made in flexible sensors for tracking body movements during sleep, which focus on their principles, mechanisms, and strategies for improved flexibility, practical applications, and future trends.
Collapse
Affiliation(s)
- Zongyi Jiang
- Institute for NanoScale Science and Technology, Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| | - Yee Sum Lee
- Institute for NanoScale Science and Technology, Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| | - Yunzhong Wang
- Institute for NanoScale Science and Technology, Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| | - Honey John
- Institute for NanoScale Science and Technology, Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
- Inter University Centre for Nanomaterials and Devices, Cochin University of Science and Technology, Kochi 682022, India
| | - Liming Fang
- Institute for NanoScale Science and Technology, Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
- National Engineering Research Centre for Tissue Restoration and Reconstruction, South China University of Technology, Guangzhou Higher Education Mega Centre, Panyu District, Guangzhou 510006, China
| | - Youhong Tang
- Institute for NanoScale Science and Technology, Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| |
Collapse
|
8
|
Wang Y, Zhao J, Zeng X, Huang J, Wen Y, Brugger J, Zhang X. All-Printed Finger-Inspired Tactile Sensor Array for Microscale Texture Detection and 3D Reconstruction. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2400479. [PMID: 38696643 PMCID: PMC11234443 DOI: 10.1002/advs.202400479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/18/2024] [Indexed: 05/04/2024]
Abstract
Electronic skins are expected to replicate a human-like tactile sense, which significantly detects surface information, including geometry, material, and temperature. Although most texture features can be sensed in the horizontal direction, the lack of effective approaches for detecting vertical properties limits the development of artificial skin based on tactile sensors. In this study, an all-printed finger-inspired tactile sensor array is developed to realize the 3D detection and reconstruction of microscale structures. A beam structure with a suspended multilayer membrane is proposed, and a tactile sensor array of 12 units arranged in a dual-column layout is developed. This architecture enables the tactile sensor array to obtain comprehensive geometric information of micro-textures, including 3D morphology and clearance characteristics, and optimizes the 3D reconstruction patterns by self-calibration. Moreover, an innovative screen-printing technology incorporating multilayer printing and sacrificial-layer techniques is adopted to print the entire device. In additon, a Braille recognition system utilizing this tactile sensor array is developed to interpret Shakespeare's quotes printed in Grade 2 Braille. The abovementioned demonstrations reveal an attractive future vision for endowing bioinspired robots with the unique capability of touching and feeling the microscale real world and reconstructing it in the cyber world.
Collapse
Affiliation(s)
- Yilin Wang
- School of Integrated Circuit Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Jiafeng Zhao
- School of Integrated Circuit Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Xu Zeng
- School of Integrated Circuit Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Jingwen Huang
- School of Integrated Circuit Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Yading Wen
- School of Integrated Circuit Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Juergen Brugger
- Microsystems Laboratory, Ecole Polytechnique Fédérale de Lausanne, Lausanne, 1015, Switzerland
| | - Xiaosheng Zhang
- School of Integrated Circuit Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China
| |
Collapse
|
9
|
Saha T, Del Caño R, De la Paz E, Sandhu SS, Wang J. Access and Management of Sweat for Non-Invasive Biomarker Monitoring: A Comprehensive Review. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2206064. [PMID: 36433842 DOI: 10.1002/smll.202206064] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/07/2022] [Indexed: 06/16/2023]
Abstract
Sweat is an important biofluid presents in the body since it regulates the internal body temperature, and it is relatively easy to access on the skin unlike other biofluids and contains several biomarkers that are also present in the blood. Although sweat sensing devices have recently displayed tremendous progress, most of the emerging devices primarily focus on the sensor development, integration with electronics, wearability, and data from in vitro studies and short-term on-body trials during exercise. To further the advances in sweat sensing technology, this review aims to present a comprehensive report on the approaches to access and manage sweat from the skin toward improved sweat collection and sensing. It is begun by delineating the sweat secretion mechanism through the skin, and the historical perspective of sweat, followed by a detailed discussion on the mechanisms governing sweat generation and management on the skin. It is concluded by presenting the advanced applications of sweat sensing, supported by a discussion of robust, extended-operation epidermal wearable devices aiming to strengthen personalized healthcare monitoring systems.
Collapse
Affiliation(s)
- Tamoghna Saha
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| | - Rafael Del Caño
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
- Department of Physical Chemistry and Applied Thermodynamics, University of Cordoba, Cordoba, E-14014, Spain
| | - Ernesto De la Paz
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| | - Samar S Sandhu
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| |
Collapse
|
10
|
Liu M, Wang S, Xiong Z, Zheng Z, Ma N, Li L, Gao Q, Ge C, Wang Y, Zhang T. Perspiration permeable, textile embeddable microfluidic sweat sensor. Biosens Bioelectron 2023; 237:115504. [PMID: 37406481 DOI: 10.1016/j.bios.2023.115504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/26/2023] [Accepted: 06/28/2023] [Indexed: 07/07/2023]
Abstract
Epidermal microfluidic devices are continuously being developed for efficient sweat collection and sweat rate detection. However, most microfluidic designs ignore the use of airtight/adhesive substrate will block the natural perspiration of the covered sweat pores, which will seriously affect normal sweat production and long-term wearable comfort. Herein, we present a Janus textile-embedded microfluidic sensor platform with high breathability and directional sweat permeability for synchronous sweat rate and total electrolyte concentration detection. The device consists of a hollowed-out serpentine microchannel with interdigital electrodes and Janus textile. The dual-mode signal of the sweat rate (0.2-4.0 μL min-1) and total ionic charge concentration (10-200 mmol L-1) can be obtained synchronously by decoupling conductance step signals generated when sweat flows through alternating interdigitated spokes at equal intervals in the microchannel. Meanwhile, the hollowed-out microchannel structure significantly reduces the coverage area of the sensor on the skin, and the Janus textile-embedded device ensures a comfortable skin/device interface (fewer sweat pores are blocked) and improves breathability (503.15 g m-2 d-1) and sweat permeability (directional liquid transportation) during long-term monitoring. This device is washable and reusable, which shows the potential to integrate with clothing and smart textile, and thus facilitate the practicality of wearable sweat sensors for personalized healthcare.
Collapse
Affiliation(s)
- Mengyuan Liu
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China; i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Shuqi Wang
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China; i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China.
| | - Zuoping Xiong
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China; i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Zhuo Zheng
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Nan Ma
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; School of Environmental and Biological Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei Road, Nanjing, Jiangsu, 210094, PR China
| | - Lianhui Li
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Qiang Gao
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Changlei Ge
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China; i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Yongfeng Wang
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Ting Zhang
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China; i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; Nano-X Vacuum Interconnected Workstation, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China.
| |
Collapse
|
11
|
Ma X, Guo G, Wu X, Wu Q, Liu F, Zhang H, Shi N, Guan Y. Advances in Integration, Wearable Applications, and Artificial Intelligence of Biomedical Microfluidics Systems. MICROMACHINES 2023; 14:mi14050972. [PMID: 37241596 DOI: 10.3390/mi14050972] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 04/20/2023] [Accepted: 04/25/2023] [Indexed: 05/28/2023]
Abstract
Microfluidics attracts much attention due to its multiple advantages such as high throughput, rapid analysis, low sample volume, and high sensitivity. Microfluidics has profoundly influenced many fields including chemistry, biology, medicine, information technology, and other disciplines. However, some stumbling stones (miniaturization, integration, and intelligence) strain the development of industrialization and commercialization of microchips. The miniaturization of microfluidics means fewer samples and reagents, shorter times to results, and less footprint space consumption, enabling a high throughput and parallelism of sample analysis. Additionally, micro-size channels tend to produce laminar flow, which probably permits some creative applications that are not accessible to traditional fluid-processing platforms. The reasonable integration of biomedical/physical biosensors, semiconductor microelectronics, communications, and other cutting-edge technologies should greatly expand the applications of current microfluidic devices and help develop the next generation of lab-on-a-chip (LOC). At the same time, the evolution of artificial intelligence also gives another strong impetus to the rapid development of microfluidics. Biomedical applications based on microfluidics normally bring a large amount of complex data, so it is a big challenge for researchers and technicians to analyze those huge and complicated data accurately and quickly. To address this problem, machine learning is viewed as an indispensable and powerful tool in processing the data collected from micro-devices. In this review, we mainly focus on discussing the integration, miniaturization, portability, and intelligence of microfluidics technology.
Collapse
Affiliation(s)
- Xingfeng Ma
- School of Communication and Information Engineering, Shanghai University, Shanghai 200000, China
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
| | - Gang Guo
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
| | - Xuanye Wu
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
| | - Qiang Wu
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| | - Fangfang Liu
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
| | - Hua Zhang
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| | - Nan Shi
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
- Institute of Translational Medicine, Shanghai University, Shanghai 200000, China
| | - Yimin Guan
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| |
Collapse
|
12
|
Ye Z, Yuan Y, Zhan S, Liu W, Fang L, Li T. Paper-based microfluidics in sweat detection: from design to application. Analyst 2023; 148:1175-1188. [PMID: 36861489 DOI: 10.1039/d2an01818g] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
Sweat, as a sample that includes a lot of biochemical information, is good for non-invasive monitoring. In recent years, there have been an increasing number of studies on in situ monitoring of sweat. However, there are still some challenges for the continuous analysis of samples. As a hydrophilic, easy-to-process, environmentally friendly, inexpensive and easily accessible material, paper is an ideal substrate material for making in situ sweat analysis microfluidics. This review introduces the development of paper as a sweat analysis microfluidic substrate material, focusing on the advantages of the structural characteristics of paper, trench design and equipment integration applications to expand the design and research ideas for the development of in situ sweat detection technology.
Collapse
Affiliation(s)
- Zhichao Ye
- Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310028, China.,School of Medicine, Zhejiang University, Hangzhou 310028, China
| | - Yuyang Yuan
- Department of Translational Medicine & Clinical Research, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310028, China. .,Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310028, China.,School of Medicine, Zhejiang University, Hangzhou 310028, China
| | - Shaowei Zhan
- School of Medicine, Zhejiang University, Hangzhou 310028, China.,Department of Dermatology and Venereology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou 310028, China
| | - Wei Liu
- College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310028, China
| | - Lu Fang
- Department of Automation, Hangzhou Dianzi University, Hangzhou 310028, China.
| | - Tianyu Li
- Department of Translational Medicine & Clinical Research, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310028, China. .,National Engineering Research Center of Innovation and Application of Minimally Invasive Instruments, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310028, China
| |
Collapse
|
13
|
Wei L, He Y, Lv Z, Guo D, Cheng L, Wu H, Liu A. Full-Cut Manufacture of Skin-Interfaced Microfluidic Patch with Copper Electrode for In Situ Admittance Sensing of Sweat Rate. BIOSENSORS 2022; 13:67. [PMID: 36671902 PMCID: PMC9855928 DOI: 10.3390/bios13010067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/28/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Sweat-rate measurement has received more and more attention, especially for specific groups, such as athletes, soldiers and manual workers, due to their excessive sweat loss under prolonged intense heat stress, which increases the risk of dehydration and electrolyte imbalance. The highly effective manufacture of a sweat-sensing device is essential to its wide range of applications in perspiration-related physiological information detection. In this work, we propose a simple and cost-effective strategy for the manufacture of a microfluidic sweat-rate-sensing patch via laser cutting and transfer printing technology. A copper foil tape is used as the electrode for in situ admittance based sweat-rate-sensing. The detection circuits and measurement conditions are optimized to prevent the negative effect of an electrochemical reaction between a copper electrode and sweat for precise admittance measurement. In vitro and on-body experiments demonstrate that the copper electrode is applicable for admittance-based sweat sensing and is capable of achieving equivalent sensing accuracy as a gold electrode and that the proposed sensor structure can perform consecutive and accurate sweat-rate-sensing and facilitates a significant increase in manufacturing efficiency.
Collapse
Affiliation(s)
- Lei Wei
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China
- School of Physics and Electronics Engineering, Fuyang Normal University, Fuyang 236037, China
| | - Yuxin He
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Zihan Lv
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Daoyou Guo
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Lin Cheng
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Huaping Wu
- Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
| | - Aiping Liu
- Key Laboratory of Optical Field Manipulation of Zhejiang Province, Zhejiang Sci-Tech University, Hangzhou 310018, China
| |
Collapse
|
14
|
Tian Y, Xu G, Cai K, Zhao X, Zhang B, Wang L, Wang T. Emerging biotransduction strategies on soft interfaces for biosensing. NANOSCALE 2022; 15:80-91. [PMID: 36512329 DOI: 10.1039/d2nr05444b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
As a lab-on-soft biochip providing accurate and timely biomarker information, wearable biosensors can satisfy the increasing demand for intelligent e-health services, active disease diagnosis/therapy, and huge bioinformation data. As biomolecules generally could not directly produce detectable signals, biotransducers that specifically convert biomolecules to electrical or optical signals are involved, which determines the pivotal sensing performance including 3S (sensitivity, selectivity, and stability), reversibility, etc. The soft interface poses new requirements for biotransducers, especially equipment-free, facile operation, mechanical tolerance, and high sensing performance. In this review, we discussed the emerging electrochemical and optical biotransduction strategies on wearables from the aspects of the transduction mechanism, amplification strategies, biomaterial selection, and device fabrication procedures. Challenges and perspectives regarding future biotransducers for monitoring trace amounts of biomolecules with high fidelity, sensitivity, and multifunctionality are also discussed. It is expected that through fusion with functional electronics, wearable biosensors can provide possibilities to further decentralize the healthcare system and even build biomolecule-based intelligent cyber-physical systems and new modalities of cyborgs.
Collapse
Affiliation(s)
- Yuanyuan Tian
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
- School of Science, Nanjing University of Posts and Telecommunications, Nanjing, 210023, China
| | - Guoliang Xu
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
| | - Kaiyu Cai
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
| | - Xiao Zhao
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
| | - Bo Zhang
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
- School of Science, Nanjing University of Posts and Telecommunications, Nanjing, 210023, China
| | - Lianhui Wang
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
| | - Ting Wang
- Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), National Jiangsu Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
| |
Collapse
|
15
|
Lin H, Yu W, Suarez JEDD, Athavan H, Wang Y, Yeung C, Lin S, Sankararaman S, Milla C, Emaminejad S. Autonomous wearable sweat rate monitoring based on digitized microbubble detection. LAB ON A CHIP 2022; 22:4267-4275. [PMID: 36268642 PMCID: PMC9757655 DOI: 10.1039/d2lc00670g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Advancements in wearable bioanalytical microsystems have enabled diurnal and (semi)continuous monitoring of physiologically-relevant indices that are accessible through probing sweat. To deliver an undistorted and physiologically-meaningful interpretation of these readings, tracking the sweat secretion rate is essential, because it allows for calibrating the biomarker readings against variations in sweat secretion and inferring the body's hydration/electrolyte homeostasis status. To realize an autonomous wearable solution with intrinsically high signal-to-noise ratio sweat rate sensing capabilities, here, we devise a digitized microbubble detection mechanism-delivered by a hybrid microfluidic/electronic system with a compact footprint. This mechanism is based on the intermittent generation of microliter-scale bubbles via electrolysis and the instantaneous measurement of their time-of-flight (and thus, velocity) via impedimetric sensing. In this way, we overcome the limitations of previously proposed sweat rate sensing modalities that are inherently susceptible to non-targeted secretion characteristics (pH, conductivity, and temperature), constrained by volume, or lack system integration for autonomous on-body operation. By deploying our solution in human subject trials, we validate the utility of our solution for seamless monitoring of exercise- and iontophoretically-induced sweat secretion profiles.
Collapse
Affiliation(s)
- Haisong Lin
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
- Department of Mechanical Engineering, University of Hong Kong, Hong Kong.
| | - Wenzhuo Yu
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
| | - Jorge Emiliano De Dios Suarez
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
| | - Harish Athavan
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
| | - Yibo Wang
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
| | | | - Shuyu Lin
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
| | | | - Carlos Milla
- Stanford School of Medicine, Stanford University, USA
| | - Sam Emaminejad
- Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, UCLA, USA.
| |
Collapse
|
16
|
Singh A, Ahmed A, Sharma A, Arya S. Graphene and Its Derivatives: Synthesis and Application in the Electrochemical Detection of Analytes in Sweat. BIOSENSORS 2022; 12:910. [PMID: 36291046 PMCID: PMC9599499 DOI: 10.3390/bios12100910] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/07/2022] [Accepted: 10/15/2022] [Indexed: 05/25/2023]
Abstract
Wearable sensors and invasive devices have been studied extensively in recent years as the demand for real-time human healthcare applications and seamless human-machine interaction has risen exponentially. An explosion in sensor research throughout the globe has been ignited by the unique features such as thermal, electrical, and mechanical properties of graphene. This includes wearable sensors and implants, which can detect a wide range of data, including body temperature, pulse oxygenation, blood pressure, glucose, and the other analytes present in sweat. Graphene-based sensors for real-time human health monitoring are also being developed. This review is a comprehensive discussion about the properties of graphene, routes to its synthesis, derivatives of graphene, etc. Moreover, the basic features of a biosensor along with the chemistry of sweat are also discussed in detail. The review mainly focusses on the graphene and its derivative-based wearable sensors for the detection of analytes in sweat. Graphene-based sensors for health monitoring will be examined and explained in this study as an overview of the most current innovations in sensor designs, sensing processes, technological advancements, sensor system components, and potential hurdles. The future holds great opportunities for the development of efficient and advanced graphene-based sensors for the detection of analytes in sweat.
Collapse
Affiliation(s)
| | | | | | - Sandeep Arya
- Department of Physics, University of Jammu, Jammu 180006, India
| |
Collapse
|
17
|
Wang S, Liu M, Yang X, Lu Q, Xiong Z, Li L, Zheng H, Feng S, Zhang T. An unconventional vertical fluidic-controlled wearable platform for synchronously detecting sweat rate and electrolyte concentration. Biosens Bioelectron 2022; 210:114351. [PMID: 35569269 DOI: 10.1016/j.bios.2022.114351] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 04/25/2022] [Accepted: 05/05/2022] [Indexed: 11/29/2022]
Abstract
Epidermal microfluidic devices with long microchannels have been developed for continuous sweat analysis, which are crucial to assess personal hydration status and underlying health conditions. However, the flow resistance in long channels and the ionic concentration variation significantly affect the accuracy of both the sweat rate and electrolyte concentration measurements. Herein, we present a novel fluidic-controlled wearable platform for synchronously dropwise-detecting the sweat rate and total electrolyte concentration. The unconventional platform consisting of a vertically shortened channel, a pair of embedded electrodes and an absorption layer, is designed to minimize the flow resistance and transform sweat fluidics into uniform micro-droplets for chronological and dropwise detection. Real-time sweat conductance is decoupled from a square-wave-like curve, where the sweat rate and electrolyte concentration can be derived from the interval time and peak value, respectively. Flexible and wearable band devices are demonstrated to show their potential application for hydration status assessment during exercises.
Collapse
Affiliation(s)
- Shuqi Wang
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Mengyuan Liu
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China
| | - Xianqing Yang
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China
| | - Qifeng Lu
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; School of Chips, XJTLU Entrepreneur College (Taicang), Xi'an Jiaotong-Liverpool University, 111 Ren'ai Road, Suzhou, Jiangsu, 215123, PR China
| | - Zuoping Xiong
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Lianhui Li
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Hui Zheng
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Simin Feng
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China
| | - Ting Zhang
- i-Lab, Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 398 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui, 230026, PR China; Vacuum Interconnected Nanotech Workstation (Nano-X), Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), 385 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; Gusu Laboratory of Materials, 388 Ruoshui Road, Suzhou, Jiangsu, 215123, PR China; Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, 320 Yueyang Road, Shanghai, 200031, PR China.
| |
Collapse
|
18
|
Stuart T, Hanna J, Gutruf P. Wearable devices for continuous monitoring of biosignals: Challenges and opportunities. APL Bioeng 2022; 6:021502. [PMID: 35464617 PMCID: PMC9010050 DOI: 10.1063/5.0086935] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 03/29/2022] [Indexed: 12/17/2022] Open
Abstract
The ability for wearable devices to collect high-fidelity biosignals continuously over weeks and months at a time has become an increasingly sought-after characteristic to provide advanced diagnostic and therapeutic capabilities. Wearable devices for this purpose face a multitude of challenges such as formfactors with long-term user acceptance and power supplies that enable continuous operation without requiring extensive user interaction. This review summarizes design considerations associated with these attributes and summarizes recent advances toward continuous operation with high-fidelity biosignal recording abilities. The review also provides insight into systematic barriers for these device archetypes and outlines most promising technological approaches to expand capabilities. We conclude with a summary of current developments of hardware and approaches for embedded artificial intelligence in this wearable device class, which is pivotal for next generation autonomous diagnostic, therapeutic, and assistive health tools.
Collapse
Affiliation(s)
- Tucker Stuart
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA
| | - Jessica Hanna
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, Arizona 85721, USA
- Bio5 Institute, University of Arizona, Tucson, Arizona 85721, USA
- Neuroscience GIDP, University of Arizona, Tucson, Arizona 85721, USA
| |
Collapse
|
19
|
Paul Kunnel B, Demuru S. An epidermal wearable microfluidic patch for simultaneous sampling, storage, and analysis of biofluids with counterion monitoring. LAB ON A CHIP 2022; 22:1793-1804. [PMID: 35316321 DOI: 10.1039/d2lc00183g] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Simultaneous access to different biofluids enables an accurate analysis of multiple analytes, leading to a precision diagnosis and appropriate medication. Additionally, establishing a relationship between various markers in different biofluids and their correlation to biomarkers in blood allows the development of an algorithmic approach, which aids non-invasive diagnosis through single parameter monitoring. However, the main bottleneck that exists in multiple biofluid analyses for its clinical implementation is the requirement of an advanced microfluidic coupled device design, which empowers simultaneous collection and monitoring. To tackle this challenge, an epidermal wearable bio-fluidic patch that facilitates simultaneous on-demand extraction, sampling, and storage of sweat and interstitial fluid (ISF) together with monitoring of their corresponding counterions is presented. The clean room free development of a biofluidic patch is realized through 3D integration of laser patterned optimized microfluidic structures, a low-cost screen-printed stimulation module, and a potentiometric chloride (Cl-) and calcium (Ca2+) ion sensing module for adequate dual biofluid sampling and analysis. The developed Cl- and Ca2+ ion-selective sensors exhibit good repeatability, selectivity, acceptable stability, and sensitivity. The proof-of-concept demonstration of the fabricated patch for simultaneous dual-sampling, storage, and monitoring of the sweat Cl- and ISF Ca2+ on a healthy volunteer during different periods of the day leverages its potential in real-time personalized healthcare clinical usages. Furthermore, the patch's electronic interface and use of wireless transmission facilitates a point-of-care non-invasive lab-on-skin application for monitoring the health status of individuals.
Collapse
Affiliation(s)
- Brince Paul Kunnel
- Soft Transducers Laboratory, École Polytechnique Fédérale de Lausanne (EPFL), 2000 Neuchatel, Switzerland
- Micro & Nano systems Centre, Tyndall National Institute, T12 R5CP Cork, Ireland.
| | - Silvia Demuru
- Soft Transducers Laboratory, École Polytechnique Fédérale de Lausanne (EPFL), 2000 Neuchatel, Switzerland
| |
Collapse
|
20
|
Sim D, Brothers MC, Slocik JM, Islam AE, Maruyama B, Grigsby CC, Naik RR, Kim SS. Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2104426. [PMID: 35023321 PMCID: PMC8895156 DOI: 10.1002/advs.202104426] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 11/19/2021] [Indexed: 05/04/2023]
Abstract
Human health and performance monitoring (HHPM) is imperative to provide information necessary for protecting, sustaining, evaluating, and improving personnel in various occupational sectors, such as industry, academy, sports, recreation, and military. While various commercially wearable sensors are on the market with their capability of "quantitative assessments" on human health, physical, and psychological states, their sensing is mostly based on physical traits, and thus lacks precision in HHPM. Minimally or noninvasive biomarkers detectable from the human body, such as body fluid (e.g., sweat, tear, urine, and interstitial fluid), exhaled breath, and skin surface, can provide abundant additional information to the HHPM. Detecting these biomarkers with novel or existing sensor technologies is emerging as critical human monitoring research. This review provides a broad perspective on the state of the art biosensor technologies for HHPM, including the list of biomarkers and their physiochemical/physical characteristics, fundamental sensing principles, and high-performance sensing transducers. Further, this paper expands to the additional scope on the key technical challenges in applying the current HHPM system to the real field.
Collapse
Affiliation(s)
- Daniel Sim
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
- Research Associateship Program (RAP)the National Academies of Sciences, Engineering and MedicineWashingtonDC20001USA
- Integrative Health & Performance Sciences DivisionUES Inc.DaytonOH45432USA
| | - Michael C. Brothers
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
- Integrative Health & Performance Sciences DivisionUES Inc.DaytonOH45432USA
| | - Joseph M. Slocik
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson Air Force BaseOH 45433USA
| | - Ahmad E. Islam
- Air Force Research LaboratorySensors DirectorateWright‐Patterson Air Force BaseOH 45433USA
| | - Benji Maruyama
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson Air Force BaseOH 45433USA
| | - Claude C. Grigsby
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
| | - Rajesh R. Naik
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
| | - Steve S. Kim
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
| |
Collapse
|
21
|
ZHOU J, MEN D, ZHANG XE. Progress in wearable sweat sensors and their applications. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1016/j.cjac.2021.11.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
22
|
Jeerapan I, Moonla C, Thavarungkul P, Kanatharana P. Lab on a body for biomedical electrochemical sensing applications: The next generation of microfluidic devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:249-279. [PMID: 35094777 DOI: 10.1016/bs.pmbts.2021.07.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This chapter highlights applications of microfluidic devices toward on-body biosensors. The emerging application of microfluidics to on-body bioanalysis is a new strategy to establish systems for the continuous, real-time, and on-site determination of informative markers present in biofluids, such as sweat, interstitial fluid, blood, saliva, and tear. Electrochemical sensors are attractive to integrate with such microfluidics due to the possibility to be miniaturized. Moreover, on-body microfluidics coupled with bioelectronics enable smart integration with modern information and communication technology. This chapter discusses requirements and several challenges when developing on-body microfluidics such as difficulties in manipulating small sample volumes while maintaining mechanical flexibility, power-consumption efficiency, and simplicity of total automated systems. We describe key components, e.g., microchannels, microvalves, and electrochemical detectors, used in microfluidics. We also introduce representatives of advanced lab-on-a-body microfluidics combined with electrochemical sensors for biomedical applications. The chapter ends with a discussion of the potential trends of research in this field and opportunities. On-body microfluidics as modern total analysis devices will continue to bring several fascinating opportunities to the field of biomedical and translational research applications.
Collapse
Affiliation(s)
- Itthipon Jeerapan
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
| | - Chochanon Moonla
- School of Chemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand
| | - Panote Thavarungkul
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Proespichaya Kanatharana
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| |
Collapse
|
23
|
Bolat G, De la Paz E, Azeredo NF, Kartolo M, Kim J, de Loyola E Silva AN, Rueda R, Brown C, Angnes L, Wang J, Sempionatto JR. Wearable soft electrochemical microfluidic device integrated with iontophoresis for sweat biosensing. Anal Bioanal Chem 2022; 414:5411-5421. [PMID: 35015101 DOI: 10.1007/s00216-021-03865-9] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 12/20/2021] [Accepted: 12/22/2021] [Indexed: 12/18/2022]
Abstract
A soft and flexible wearable sweat epidermal microfluidic device capable of simultaneously stimulating, collecting, and electrochemically analyzing sweat is demonstrated. The device represents the first system integrating an iontophoretic pilocarpine delivery system around the inlet channels of epidermal polydimethylsiloxane (PDMS) microfluidic device for sweat collection and analysis. The freshly generated sweat is naturally pumped into the fluidic inlet without the need of exercising. Soft skin-mounted systems, incorporating non-invasive, on-demand sweat sampling/analysis interfaces for tracking target biomarkers, are in urgent need. Existing skin conformal microfluidic-based sensors for continuous monitoring of target sweat biomarkers rely on assays during intense physical exercising. This work demonstrates the first example of combining sweat stimulation, through transdermal pilocarpine delivery, with sample collection through a microfluidic channel for real-time electrochemical monitoring of sweat glucose, in a fully integrated soft and flexible multiplexed device which eliminates the need of exercising. The on-body operational performance and layout of the device were optimized considering the fluid dynamics and evaluated for detecting sweat glucose in several volunteers. Furthermore, the microfluidic monitoring device was integrated with a real-time wireless data transmission system using a flexible electronic board PCB conformal with the body. The new microfluidic platform paves the way to real-time non-invasive monitoring of biomarkers in stimulated sweat samples for diverse healthcare and wellness applications.
Collapse
Affiliation(s)
- Gulcin Bolat
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Ernesto De la Paz
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Nathalia F Azeredo
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
- Department of Fundamental Chemistry, Institute of Chemistry, University of Sao Paulo, Sao Paulo, Brazil
| | - Michael Kartolo
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Jayoung Kim
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | | | - Ricardo Rueda
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Christopher Brown
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Lúcio Angnes
- Department of Fundamental Chemistry, Institute of Chemistry, University of Sao Paulo, Sao Paulo, Brazil
| | - Joseph Wang
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA.
| | - Juliane R Sempionatto
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, USA.
| |
Collapse
|
24
|
Zhong B, Jiang K, Wang L, Shen G. Wearable Sweat Loss Measuring Devices: From the Role of Sweat Loss to Advanced Mechanisms and Designs. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2103257. [PMID: 34713981 PMCID: PMC8728835 DOI: 10.1002/advs.202103257] [Citation(s) in RCA: 57] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/15/2021] [Indexed: 05/22/2023]
Abstract
Wearable sweat sensors have received significant research interest and have become popular as sweat contains considerable health information about physiological and psychological states. However, measured biomarker concentrations vary with sweat rates, which has a significant effect on the accuracy and reliability of sweat biosensors. Wearable sweat loss measuring devices (SLMDs) have recently been proposed to overcome the limitations of biomarker tracking and reduce inter- and intraindividual variability. In addition, they offer substantial potential for monitoring human body homeostasis, because sweat loss plays an indispensable role in thermoregulation and skin hydration. Previous studies have not carried out a comprehensive and systematic review of the principles, importance, and development of wearable SLMDs. This paper reviews wearable SLMDs with a new health perspective from the role of sweat loss to advanced mechanisms and designs. Two types of sweat and their measurement significance for practical applications are highlighted. Then, a comprehensive review of advances in different wearable SLMDs based on hygrometers, absorbent materials, and microfluidics is presented by describing their respective device architectures, present situations, and future directions. Finally, concluding remarks on opportunities for future application fields and challenges for future sweat sensing are presented.
Collapse
Affiliation(s)
- Bowen Zhong
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Kai Jiang
- Faculty of Hepato-Pancreato-Biliary Surgery, Chinese PLA General Hospital, Institute of Hepatobiliary Surgery of Chinese PLA, Key Laboratory of Digital Hepatobiliary Surgery, Chinese PLA, Beijing, 100853, China
| | - Lili Wang
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Guozhen Shen
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| |
Collapse
|
25
|
|
26
|
Alginate Bead Biosystem for the Determination of Lactate in Sweat Using Image Analysis. BIOSENSORS-BASEL 2021; 11:bios11100379. [PMID: 34677335 PMCID: PMC8534122 DOI: 10.3390/bios11100379] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 09/30/2021] [Accepted: 10/04/2021] [Indexed: 11/18/2022]
Abstract
Lactate is present in sweat at high concentrations, being a metabolite of high interest in sport science and medicine. Therefore, the potential to determine lactate concentrations in physiological fluids, at the point of need with minimal invasiveness, is very valuable. In this work, the synthesis and performance of an alginate bead biosystem was investigated. Artificial sweat with different lactate concentrations was used as a proof of concept. The lactate detection was based on a colorimetric assay and an image analysis method using lactate oxidase, horseradish peroxidase and tetramethyl benzidine as the reaction mix. Lactate in artificial sweat was detected with a R² = 0.9907 in a linear range from 10 mM to 100 mM, with a limit of detection of 6.4 mM and a limit of quantification of 21.2 mM. Real sweat samples were used as a proof of concept to test the performance of the biosystem, obtaining a lactate concentration of 48 ± 3 mM. This novel sensing configuration, using alginate beads, gives a fast and reliable method for lactate sensing, which could be integrated into more complex analytical systems.
Collapse
|
27
|
Stuart T, Kasper KA, Iwerunmor IC, McGuire DT, Peralta R, Hanna J, Johnson M, Farley M, LaMantia T, Udorvich P, Gutruf P. Biosymbiotic, personalized, and digitally manufactured wireless devices for indefinite collection of high-fidelity biosignals. SCIENCE ADVANCES 2021; 7:eabj3269. [PMID: 34623919 PMCID: PMC8500520 DOI: 10.1126/sciadv.abj3269] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 08/16/2021] [Indexed: 05/12/2023]
Abstract
Digital medicine, the ability to stream continuous information from the body to gain insight into health status, manage disease, and predict onset health problems, is only gradually developing. Key technological hurdles that slow the proliferation of this approach are means by which clinical grade biosignals are continuously obtained without frequent user interaction. To overcome these hurdles, solutions in power supply and interface strategies that maintain high-fidelity readouts chronically are critical. This work introduces a previously unexplored class of devices that overcomes the limitations using digital manufacturing to tailor geometry, mechanics, electromagnetics, electronics, and fluidics to create unique personalized devices optimized to the wearer. These elastomeric, three-dimensional printed, and laser-structured constructs, called biosymbiotic devices, enable adhesive-free interfaces and the inclusion of high-performance, far-field energy harvesting to facilitate continuous wireless and battery-free operation of multimodal and multidevice, high-fidelity biosensing in an at-home setting without user interaction.
Collapse
Affiliation(s)
- Tucker Stuart
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | | | - Dylan Thomas McGuire
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Roberto Peralta
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Jessica Hanna
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Megan Johnson
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Max Farley
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Thomas LaMantia
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Paul Udorvich
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ 85721, USA
- Bio5 Institute, University of Arizona, Tucson, AZ 85721, USA
- Neroscience GIDP, University of Arizona, Tucson, AZ 85721, USA
| |
Collapse
|
28
|
Lee EK, Baruah RK, Bhamra H, Kim YJ, Yoo H. Recent advances in electrode development for biomedical applications. Biomed Eng Lett 2021; 11:107-115. [PMID: 34150347 DOI: 10.1007/s13534-021-00189-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 03/27/2021] [Accepted: 04/10/2021] [Indexed: 11/24/2022] Open
Abstract
Elaborate electrodes that enable adhesion to the skin surface and effectively collect vital signs are necessitated. In recent years, various electrode materials and novel structures have been developed, and they have garnered scientific attention due to their higher sensing performances compared with those of conventional electrode-based sensors. This paper provides an overview of recent advances in biomedical sensors, focusing on the development of novel electrodes. We comprehensively review the different types of electrode materials in the context of efficient biosignal detection, with respect to material composition for flexible and wearable electrodes and novel electrode structures. Finally, we discuss recent packaging technologies in biomedical applications using flexible and wearable electrodes.
Collapse
Affiliation(s)
- Eun Kwang Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907 USA.,MLCC Development, 1 team, Samsung Electro-Mechanics, 150, Maeyeong-ro, Yeongtong-gu, Suwon, Gyeonggi-do Republic of Korea
| | - Ratul Kumar Baruah
- Department of Electronics and Communication Engineering, Tezpur University, Assam, 784028 India
| | - Hansraj Bhamra
- Department of Electrical and Computer Engineering, Center for implantable devices, Purdue University, West Lafayette, IN 47907 USA
| | - Young-Joon Kim
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Seongnam, 13120 Republic of Korea
| | - Hocheon Yoo
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Seongnam, 13120 Republic of Korea
| |
Collapse
|
29
|
Jo S, Sung D, Kim S, Koo J. A review of wearable biosensors for sweat analysis. Biomed Eng Lett 2021; 11:117-129. [PMID: 34150348 DOI: 10.1007/s13534-021-00191-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 04/26/2021] [Accepted: 04/30/2021] [Indexed: 11/26/2022] Open
Abstract
Recent advances in the skin-interfaced wearable sweat sensors allow a personalized daily diagnosis and prognosis of the diseases in a form of a non-invasive, portable, and continuous monitoring system. Especially, the soft microfluidic system provides robust quantitative analysis platforms that integrate sweat sampling, storing, and various sensing capabilities. This review systematically introduces the sweat collecting mechanism using soft microfluidic valves, including calculation of sweat storage and loss. In terms of sweat analysis, colorimetric (e.g. enzymatic, chemical, or their mixed reactions), electrochemical (e.g. voltammetric, potentiometric, amperometric, or conductometric), and multiplex measurements of sweat contents facilitate diagnosis of diseases via analysis of combined multiple data, such as vital signals (e.g. ECG, EMG, EEG, etc.) and information from the skin (e.g. temperature, GSR, etc.). The integration of wireless communication with the microfluidic systems enables point-of-care health monitoring for disease and specific physiological status.
Collapse
Affiliation(s)
- Seongbin Jo
- School of Biomedical Engineering, Korea University, Seoul, 02841 Republic of Korea
| | - Daeun Sung
- School of Biomedical Engineering, Korea University, Seoul, 02841 Republic of Korea
| | - Sungbong Kim
- Department of Materials Science and Engineering and Materials Research Laboratory, University of Illinois At Urbana-Champaign, Urbana, IL 61801 USA
| | - Jahyun Koo
- School of Biomedical Engineering, Korea University, Seoul, 02841 Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841 Republic of Korea
| |
Collapse
|
30
|
Yokus BMA, Daniele MA. Integrated non-invasive biochemical and biophysical sensing systems for health and performance monitoring: A systems perspective. Biosens Bioelectron 2021; 184:113249. [PMID: 33895689 DOI: 10.1016/j.bios.2021.113249] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 04/09/2021] [Accepted: 04/12/2021] [Indexed: 12/21/2022]
Abstract
Advances in materials, bio-recognition elements, transducers, and microfabrication techniques, as well as progress in electronics, signal processing, and wireless communication have generated a new class of skin-interfaced wearable health monitoring systems for applications in personalized medicine and digital health. In comparison to conventional medical devices, these wearable systems are at the cusp of initiating a new era of longitudinal and noninvasive sensing for the prevention, detection, diagnosis, and treatment of diseases at the molecular level. Herein, we provide a review of recent developments in wearable biochemical and biophysical systems. We survey the sweat sampling and collection methods for biochemical systems, followed by an assessment of biochemical and biophysical sensors deployed in current wearable systems with an emphasis on their hardware specifications. Specifically, we address how sweat collection and sample handling platforms may be a rate limiting technology to realizing the clinical translation of wearable health monitoring systems; moreover, we highlight the importance of achieving both longitudinal sensing and assessment of intrapersonal variation in sweat-blood correlations to have the greatest clinical impact. Lastly, we assess a snapshot of integrated wireless wearable systems with multimodal sensing capabilities, and we conclude with our perspective on the state-of-the-art and the required developments to achieve the next-generation of integrated wearable health and performance monitoring systems.
Collapse
Affiliation(s)
- By Murat A Yokus
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC, 27695, USA
| | - Michael A Daniele
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC, 27695, USA; Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, 911 Oval Dr., Raleigh, NC, 27695, USA.
| |
Collapse
|
31
|
Review of 3D-printing technologies for wearable and implantable bio-integrated sensors. Essays Biochem 2021; 65:491-502. [PMID: 33860794 DOI: 10.1042/ebc20200131] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 03/10/2021] [Accepted: 03/22/2021] [Indexed: 01/16/2023]
Abstract
Thin-film microfabrication-based bio-integrated sensors are widely used for a broad range of applications that require continuous measurements of biophysical and biochemical signals from the human body. Typically, they are fabricated using standard photolithography and etching techniques. This traditional method is capable of producing a precise, thin, and flexible bio-integrated sensor system. However, it has several drawbacks, such as the fact that it can only be used to fabricate sensors on a planar surface, it is highly complex requiring specialized high-end facilities and equipment, and it mostly allows only 2D features to be fabricated. Therefore, developing bio-integrated sensors via 3D-printing technology has attracted particular interest. 3D-printing technology offers the possibility to develop sensors on nonplanar substrates, which is beneficial for noninvasive bio-signal sensing, and to directly print on complex 3D nonplanar organ structures. Moreover, this technology introduces a highly flexible and precisely controlled printing process to realize patient-specific sensor systems for ultimate personalized medicine, with the potential of rapid prototyping and mass customization. This review summarizes the latest advancements in 3D-printed bio-integrated systems, including 3D-printing methods and employed printing materials. Furthermore, two widely used 3D-printing techniques are discussed, namely, ex-situ and in-situ fabrication techniques, which can be utilized in different types of applications, including wearable and smart-implantable biosensor systems.
Collapse
|
32
|
Stuart T, Cai L, Burton A, Gutruf P. Wireless and battery-free platforms for collection of biosignals. Biosens Bioelectron 2021; 178:113007. [PMID: 33556807 PMCID: PMC8112193 DOI: 10.1016/j.bios.2021.113007] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/02/2021] [Accepted: 01/14/2021] [Indexed: 02/06/2023]
Abstract
Recent progress in biosensors have quantitively expanded current capabilities in exploratory research tools, diagnostics and therapeutics. This rapid pace in sensor development has been accentuated by vast improvements in data analysis methods in the form of machine learning and artificial intelligence that, together, promise fantastic opportunities in chronic sensing of biosignals to enable preventative screening, automated diagnosis, and tools for personalized treatment strategies. At the same time, the importance of widely accessible personal monitoring has become evident by recent events such as the COVID-19 pandemic. Progress in fully integrated and chronic sensing solutions is therefore increasingly important. Chronic operation, however, is not truly possible with tethered approaches or bulky, battery-powered systems that require frequent user interaction. A solution for this integration challenge is offered by wireless and battery-free platforms that enable continuous collection of biosignals. This review summarizes current approaches to realize such device architectures and discusses their building blocks. Specifically, power supplies, wireless communication methods and compatible sensing modalities in the context of most prevalent implementations in target organ systems. Additionally, we highlight examples of current embodiments that quantitively expand sensing capabilities because of their use of wireless and battery-free architectures.
Collapse
Affiliation(s)
- Tucker Stuart
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Le Cai
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA; Department of Electrical Engineering, University of Arizona, Tucson, AZ, 85721, USA; Bio5 Institute, University of Arizona, Tucson, AZ, 85721, USA; Neuroscience GIDP, University of Arizona, Tucson, AZ, 85721, USA.
| |
Collapse
|
33
|
Ghaffari R, Rogers JA, Ray TR. Recent progress, challenges, and opportunities for wearable biochemical sensors for sweat analysis. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 332:129447. [PMID: 33542590 PMCID: PMC7853653 DOI: 10.1016/j.snb.2021.129447] [Citation(s) in RCA: 87] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Sweat is a promising, yet relatively unexplored biofluid containing biochemical information that offers broad insights into the underlying dynamic metabolic activity of the human body. The rich composition of electrolytes, metabolites, hormones, proteins, nucleic acids, micronutrients, and exogenous agents found in sweat dynamically vary in response to the state of health, stress, and diet. Emerging classes of skin-interfaced wearable sensors offer powerful capabilities for the real-time, continuous analysis of sweat produced by the eccrine glands in a manner suitable for use in athletics, consumer wellness, military, and healthcare industries. This perspective examines the rapid and continuous progress of wearable sweat sensors through the most advanced embodiments that address the fundamental challenges currently restricting widespread deployment. It concludes with a discussion of efforts to expand the overall utility of wearable sweat sensors and opportunities for commercialization, in which advances in biochemical sensor technologies will be critically important.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- -Querrey Simpson Institute for Bioelectronics and Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- -Epicore Biosystems, Inc., Cambridge, MA, USA
| | - John A. Rogers
- -Querrey Simpson Institute for Bioelectronics and Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- -Epicore Biosystems, Inc., Cambridge, MA, USA
- -Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, Chemistry, Northwestern University, Evanston, IL, USA
- -Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Tyler R. Ray
- -Department of Mechanical Engineering, University of Hawai‘i at Mānoa, Honolulu, HI
| |
Collapse
|
34
|
Ray TR, Ivanovic M, Curtis PM, Franklin D, Guventurk K, Jeang WJ, Chafetz J, Gaertner H, Young G, Rebollo S, Model JB, Lee SP, Ciraldo J, Reeder JT, Hourlier-Fargette A, Bandodkar AJ, Choi J, Aranyosi AJ, Ghaffari R, McColley SA, Haymond S, Rogers JA. Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management. Sci Transl Med 2021; 13:eabd8109. [PMID: 33790027 PMCID: PMC8351625 DOI: 10.1126/scitranslmed.abd8109] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 03/02/2021] [Indexed: 12/14/2022]
Abstract
The concentration of chloride in sweat remains the most robust biomarker for confirmatory diagnosis of cystic fibrosis (CF), a common life-shortening genetic disorder. Early diagnosis via quantitative assessment of sweat chloride allows prompt initiation of care and is critically important to extend life expectancy and improve quality of life. The collection and analysis of sweat using conventional wrist-strapped devices and iontophoresis can be cumbersome, particularly for infants with fragile skin, who often have insufficient sweat production. Here, we introduce a soft, epidermal microfluidic device ("sweat sticker") designed for the simple and rapid collection and analysis of sweat. Intimate, conformal coupling with the skin supports nearly perfect efficiency in sweat collection without leakage. Real-time image analysis of chloride reagents allows for quantitative assessment of chloride concentrations using a smartphone camera, without requiring extraction of sweat or external analysis. Clinical validation studies involving patients with CF and healthy subjects, across a spectrum of age groups, support clinical equivalence compared to existing device platforms in terms of accuracy and demonstrate meaningful reductions in rates of leakage. The wearable microfluidic technologies and smartphone-based analytics reported here establish the foundation for diagnosis of CF outside of clinical settings.
Collapse
Affiliation(s)
- Tyler R Ray
- Department of Mechanical Engineering, University of Hawaii at Manoa, Honolulu, HI 96822, USA
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Maja Ivanovic
- Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Paul M Curtis
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Daniel Franklin
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Kerem Guventurk
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60202, USA
| | - William J Jeang
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Joseph Chafetz
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Hannah Gaertner
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Grace Young
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
| | - Steve Rebollo
- Pritzker School of Molecular Engineering and Department of Physics, University of Chicago, Chicago, IL 60637, USA
| | - Jeffrey B Model
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Epicore Biosystems Inc., Cambridge, MA 02139, USA
| | - Stephen P Lee
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Epicore Biosystems Inc., Cambridge, MA 02139, USA
| | - John Ciraldo
- Micro/Nano Fabrication Facility (NUFAB) Northwestern University, Evanston, IL 60202, USA
| | - Jonathan T Reeder
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
| | - Aurélie Hourlier-Fargette
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Université de Strasbourg, CNRS, Institut Charles Sadron UPR22, F-67000, Strasbourg 67034, France
| | - Amay J Bandodkar
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
| | - Jungil Choi
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- School of Mechanical Engineering, Kookmin University, Seoul 02707, Republic of Korea
| | - Alexander J Aranyosi
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Epicore Biosystems Inc., Cambridge, MA 02139, USA
| | - Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60202, USA
- Epicore Biosystems Inc., Cambridge, MA 02139, USA
| | - Susanna A McColley
- Department of Pediatrics, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
- Division of Pulmonary and Sleep Medicine, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL 60611, USA
| | - Shannon Haymond
- Department of Pathology, Northwestern Feinberg School of Medicine, Chicago, IL 60611, USA
- Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL 60611, USA
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60202, USA.
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60202, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60202, USA
- Epicore Biosystems Inc., Cambridge, MA 02139, USA
- Department of Mechanical Engineering, Department of Electrical and Computer Engineering, Department of Chemistry, Northwestern University, Evanston, IL 60202, USA
- Department of Neurological Surgery Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| |
Collapse
|
35
|
Vinoth R, Nakagawa T, Mathiyarasu J, Mohan AMV. Fully Printed Wearable Microfluidic Devices for High-Throughput Sweat Sampling and Multiplexed Electrochemical Analysis. ACS Sens 2021; 6:1174-1186. [PMID: 33517662 DOI: 10.1021/acssensors.0c02446] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Although the recent advancement in wearable biosensors provides continuous, noninvasive assessment of physiologically relevant chemical markers from human sweat, several bottlenecks still exist for its practical use. There were challenges in developing a multiplexed biosensing system with rapid microfluidic sampling and transport properties, as well as its integration with a portable potentiostat for improved interference-free data collection. Here, we introduce a clean-room free fabrication of wearable microfluidic sensors, using a screen-printed carbon master, for the electrochemical monitoring of sweat biomarkers during exercise activities. The sweat sampling is enhanced by introducing low-dimensional sensing compartments and lowering the hydrophilicity of channel layers via facile silane functionalization. The fluidic channel captures sweat at the inlet and directs the real-time sweat through the active sensing electrodes (within 40 s) for subsequent decoding and selective analyses. For proof of concept, simultaneous amperometric lactate and potentiometric ion sensing (Na+, K+, and pH) are carried out by a miniature circuit board capable of cross-talk-free signal collection and wireless signal transduction characteristics. All of the sensors demonstrated appreciable sensitivity, selectivity, stability, carryover efficiency, and repeatability. The floating potentiometric circuits eliminate the signal interference from the adjacent amperometric transducers. The fully integrated pumpless microfluidic device is mounted on the epidermis and employed for multiplexed real-time decoding of sweat during stationary biking. The regional variations in sweat composition are analyzed by human trials at the underarm and upperback locations. The presented method offers a large-scale fabrication of inexpensive high-throughput wearable sensors for personalized point-of-care and athletic applications.
Collapse
Affiliation(s)
- Rajendran Vinoth
- Electrodics and Electrocatalysis Division, CSIR—Central Electrochemical Research Institute (CECRI), Karaikudi 630003, Tamil Nadu, India
- Academy of Scientific and Innovative Research (AcSIR)—CSIR, Ghaziabad 201002, Uttar Pradesh, India
| | - Tatsuo Nakagawa
- Research & Development Group, Hitachi, Ltd., 1-280 Higashi-koigakubo, Kokubunji-shi, Tokyo1858601, Japan
| | - Jayaraman Mathiyarasu
- Electrodics and Electrocatalysis Division, CSIR—Central Electrochemical Research Institute (CECRI), Karaikudi 630003, Tamil Nadu, India
- Academy of Scientific and Innovative Research (AcSIR)—CSIR, Ghaziabad 201002, Uttar Pradesh, India
| | - A. M. Vinu Mohan
- Electrodics and Electrocatalysis Division, CSIR—Central Electrochemical Research Institute (CECRI), Karaikudi 630003, Tamil Nadu, India
- Academy of Scientific and Innovative Research (AcSIR)—CSIR, Ghaziabad 201002, Uttar Pradesh, India
| |
Collapse
|
36
|
Zhang S, Zahed MA, Sharifuzzaman M, Yoon S, Hui X, Chandra Barman S, Sharma S, Yoon HS, Park C, Park JY. A wearable battery-free wireless and skin-interfaced microfluidics integrated electrochemical sensing patch for on-site biomarkers monitoring in human perspiration. Biosens Bioelectron 2021; 175:112844. [PMID: 33248878 DOI: 10.1016/j.bios.2020.112844] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/06/2020] [Accepted: 11/20/2020] [Indexed: 01/19/2023]
Abstract
In this study, an ultra-high sensitive, flexible, wireless, battery-free, and fully integrated (no external analysis equipment) electrochemical sensing patch system, including a microfluidic-sweat collecting unit, was newly developed for the on-site monitoring of the [K+] concentration in human sweat. Multiwalled carbon nanotube (MWCNT) and MXene-Ti3C2TX based hybrid multi-dimensional networks were applied to obtain a high surface activation area and faster charge transfer rate, strongly adsorbing the valinomycin membrane to protect the ionophore for effective transshipment and immobilization of the [K+]. Furthermore, the controllable porosity of carbon-based materials can accelerate the kinetic process of ion diffusion. This hybrid nanonetwork structure effectively enhanced electrochemical stability and sensitivity, addressing the noise and signal drifting problems experienced with low concentration detection. The fabricated sensor exhibited a high ion concentration sensitivity of 63 mV/dec with excellent selectivity, amplified to 173 mV/dec with the integrated amplification system. The Near Field Communication (NFC) is used to transmit measurements to a smartphone wirelessly. A microfluidic channel was integrated with the electrochemical sensor patch to efficiently collect sweat on the human skin surface and mitigate the sensor surface contamination problem. Furthermore, the developed sensing patch can also be applied to other biomarkers on-site detection after modifying the working electrode with the corresponding selective membranes.
Collapse
Affiliation(s)
- Shipeng Zhang
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Md Abu Zahed
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Md Sharifuzzaman
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Sanghyuk Yoon
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Xue Hui
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Sharat Chandra Barman
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Sudeep Sharma
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Hyo Sang Yoon
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Chani Park
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea
| | - Jae Yeong Park
- Department of Electronic Engineering, Kwangwoon University, 447-1 Wolgye-dong, Nowongu, Seoul, 01897, Republic of Korea.
| |
Collapse
|
37
|
Choi J, Chen S, Deng Y, Xue Y, Reeder JT, Franklin D, Oh YS, Model JB, Aranyosi AJ, Lee SP, Ghaffari R, Huang Y, Rogers JA. Skin-Interfaced Microfluidic Systems that Combine Hard and Soft Materials for Demanding Applications in Sweat Capture and Analysis. Adv Healthc Mater 2021; 10:e2000722. [PMID: 32989913 DOI: 10.1002/adhm.202000722] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 06/17/2020] [Indexed: 01/05/2023]
Abstract
Eccrine sweat contains a rich blend of electrolytes, metabolites, proteins, metal ions, and other biomarkers. Changes in the concentrations of these chemical species can indicate alterations in hydration status and they can also reflect health conditions such as cystic fibrosis, schizophrenia, and depression. Recent advances in soft, skin-interfaced microfluidic systems enable real-time measurement of local sweat loss and sweat biomarker concentrations, with a wide range of applications in healthcare. Uses in certain contexts involve, however, physical impacts on the body that can dynamically deform these platforms, with adverse effects on measurement reliability. The work presented here overcomes this limitation through the use of microfluidic structures constructed in relatively high modulus polymers, and designed in geometries that offer soft, system level mechanics when embedded low modulus elastomers. Analytical models and finite element analysis quantitatively define the relevant mechanics of these systems, and serve as the basis for layouts optimized to allow robust operation in demanding, rugged scenarios such as those encountered in football, while preserving mechanical stretchability for comfortable, water-tight bonding to the skin. Benchtop testing and on-body field studies of measurements of sweat loss and chloride concentration under imposed mechanical stresses and impacts demonstrate the key features of these platforms.
Collapse
Affiliation(s)
- Jungil Choi
- School of Mechanical Engineering Kookmin University Seoul 02707 Republic of Korea
| | - Shulin Chen
- Department of Biomedical Engineering Northwestern University Evanston IL 60208 USA
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
| | - Yujun Deng
- State Key Laboratory of Mechanical System and Vibration Shanghai Jiao Tong University Shanghai 200240 China
- Department of Civil and Environmental Engineering Mechanical Engineering and Materials Science and Engineering Northwestern University Evanston IL 60208 USA
| | - Yeguang Xue
- Department of Civil and Environmental Engineering Mechanical Engineering and Materials Science and Engineering Northwestern University Evanston IL 60208 USA
| | - Jonathan T. Reeder
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA
| | - Daniel Franklin
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA
| | - Yong Suk Oh
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA
| | - Jeffrey B. Model
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Epicore Biosystems, Inc. Cambridge MA 02139 USA
| | - Alexander J. Aranyosi
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Epicore Biosystems, Inc. Cambridge MA 02139 USA
| | - Stephen P. Lee
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Epicore Biosystems, Inc. Cambridge MA 02139 USA
| | - Roozbeh Ghaffari
- Department of Biomedical Engineering Northwestern University Evanston IL 60208 USA
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Epicore Biosystems, Inc. Cambridge MA 02139 USA
| | - Yonggang Huang
- Department of Civil and Environmental Engineering Mechanical Engineering and Materials Science and Engineering Northwestern University Evanston IL 60208 USA
| | - John A. Rogers
- Department of Biomedical Engineering Northwestern University Evanston IL 60208 USA
- Querrey‐Simpson Institute for Bioelectronics Northwestern University Evanston IL 60208 USA
- Department of Materials Science and Engineering Northwestern University Evanston IL 60208 USA
- Departments of Chemistry Biomedical Engineering and Electrical Engineering and Computer Science Northwestern University Evanston IL 60208 USA
- Department of Neurological Surgery Northwestern University Evanston IL 60208 USA
| |
Collapse
|
38
|
Zhou W, Lin R, Li H, Liu R. Nano Foldaway Skin-like E-interface for Detecting Human Bioelectrical Signals. ACS APPLIED MATERIALS & INTERFACES 2021; 13:148-154. [PMID: 33372765 DOI: 10.1021/acsami.0c16981] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Flexible electrodes applied to different positions of the human body to detect bioelectrical signals need to be conductive with respect to both the skin and the external circuit. However, electrodes fabricated with micromachining can only be made conductive on one side, which requires inserting connection wires, thus affecting skin adhesion and leading to a more fragile circuit on the soft substrate. This paper proposes an e-interface designed with an innovative folding transfer process, which can fold nanometer thick electrodes in a macroscopic way. Avoiding the difficulties of fabricating double layer as well as an insulation layer, the e-interface is not only skin-conformable for long-term wear but also provides a stable connecting pad for the subsequent circuit by its double-sided conductivity. The e-interface can be stretched to more than 25% of its original length and achieve electrical stability in the long-term signal acquisition. A responsive ECG signal is obtained by the e-interface, and the signal remains stable during exercise.
Collapse
Affiliation(s)
- Wanting Zhou
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Rongzan Lin
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Haojie Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Ran Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| |
Collapse
|
39
|
Wearable strain sensor for real-time sweat volume monitoring. iScience 2020; 24:102028. [PMID: 33490926 PMCID: PMC7809499 DOI: 10.1016/j.isci.2020.102028] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 12/13/2020] [Accepted: 12/29/2020] [Indexed: 01/05/2023] Open
Abstract
Reliably monitoring sweat volume has attracted much attention due to its important role in the assessment of physiological health conditions and the prevention of dehydration. Here, we present the first example of wearable strain sensor for real-time sweat volume monitoring. Such sweat volume monitoring sensor is simply fabricated via embedding strain sensing fabric in super-absorbent hydrogels, the hydrogels can wick sweat up off the skin surface to swell and then trigger the strain sensing fabrics response. This sensor can realize real-time detection of sweat volume (0.15-700 μL), shows excellent repeatability and stability against movement or light interference, reliability in the non-pathological range (pH: 4-9 and salinity: 0-100 mM NaCl) in addition. Such sensor combing swellable hydrogels with strain sensing fabrics provides a novel measurement method of wearable devices for sweat volume monitoring.
Collapse
|
40
|
Ye S, Feng S, Huang L, Bian S. Recent Progress in Wearable Biosensors: From Healthcare Monitoring to Sports Analytics. BIOSENSORS 2020; 10:E205. [PMID: 33333888 PMCID: PMC7765261 DOI: 10.3390/bios10120205] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 12/11/2020] [Accepted: 12/13/2020] [Indexed: 02/07/2023]
Abstract
Recent advances in lab-on-a-chip technology establish solid foundations for wearable biosensors. These newly emerging wearable biosensors are capable of non-invasive, continuous monitoring by miniaturization of electronics and integration with microfluidics. The advent of flexible electronics, biochemical sensors, soft microfluidics, and pain-free microneedles have created new generations of wearable biosensors that explore brand-new avenues to interface with the human epidermis for monitoring physiological status. However, these devices are relatively underexplored for sports monitoring and analytics, which may be largely facilitated by the recent emergence of wearable biosensors characterized by real-time, non-invasive, and non-irritating sensing capacities. Here, we present a systematic review of wearable biosensing technologies with a focus on materials and fabrication strategies, sampling modalities, sensing modalities, as well as key analytes and wearable biosensing platforms for healthcare and sports monitoring with an emphasis on sweat and interstitial fluid biosensing. This review concludes with a summary of unresolved challenges and opportunities for future researchers interested in these technologies. With an in-depth understanding of the state-of-the-art wearable biosensing technologies, wearable biosensors for sports analytics would have a significant impact on the rapidly growing field-microfluidics for biosensing.
Collapse
Affiliation(s)
- Shun Ye
- Microfluidics Research & Innovation Laboratory, School of Sport Science, Beijing Sport University, Beijing 100084, China;
- Biomedical Engineering Department, College of Engineering, Pennsylvania State University, University Park, PA 16802, USA
- State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, China
| | - Shilun Feng
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China;
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Liang Huang
- School of Instrument Science and Opto–Electronics Engineering, Hefei University of Technology, Hefei 230009, China;
| | - Shengtai Bian
- Microfluidics Research & Innovation Laboratory, School of Sport Science, Beijing Sport University, Beijing 100084, China;
| |
Collapse
|
41
|
Hourlier-Fargette A, Schon S, Xue Y, Avila R, Li W, Gao Y, Liu C, Kim SB, Raj MS, Fields KB, Parsons BV, Lee K, Lee JY, Chung HU, Lee SP, Johnson M, Bandodkar AJ, Gutruf P, Model JB, Aranyosi AJ, Choi J, Ray TR, Ghaffari R, Huang Y, Rogers JA. Skin-interfaced soft microfluidic systems with modular and reusable electronics for in situ capacitive sensing of sweat loss, rate and conductivity. LAB ON A CHIP 2020; 20:4391-4403. [PMID: 33089837 PMCID: PMC10556535 DOI: 10.1039/d0lc00705f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Important insights into human health can be obtained through the non-invasive collection and detailed analysis of sweat, a biofluid that contains a wide range of essential biomarkers. Skin-interfaced microfluidic platforms, characterized by soft materials and thin geometries, offer a collection of capabilities for in situ capture, storage, and analysis of sweat and its constituents. In ambulatory uses cases, the ability to provide real-time feedback on sweat loss, rate and content, without visual inspection of the device, can be important. This paper introduces a low-profile skin-interfaced system that couples disposable microfluidic sampling devices with reusable 'stick-on' electrodes and wireless readout electronics that remain isolated from the sweat. An ultra-thin capping layer on the microfluidic platform permits high-sensitivity, contactless capacitive measurements of both sweat loss and sweat conductivity. This architecture avoids the potential for corrosion of the sensing components and eliminates the need for cleaning/sterilizing the electronics, thereby resulting in a cost-effective platform that is simple to use. Optimized electrode designs follow from a combination of extensive benchtop testing, analytical calculations and FEA simulations for two sensing configurations: (1) sweat rate and loss, and (2) sweat conductivity, which contains information about electrolyte content. Both configurations couple to a flexible, wireless electronics platform that digitizes and transmits information to Bluetooth-enabled devices. On-body field testing during physical exercise validates the performance of the system in scenarios of practical relevance to human health and performance.
Collapse
|
42
|
Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities. Proc Natl Acad Sci U S A 2020; 117:27906-27915. [PMID: 33106394 PMCID: PMC7668081 DOI: 10.1073/pnas.2012700117] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Soft microfluidic systems that capture, store, and perform biomarker analysis of microliter volumes of sweat, in situ, as it emerges from the surface of the skin, represent an emerging class of wearable technology with powerful capabilities that complement those of traditional biophysical sensing devices. Recent work establishes applications in the real-time characterization of sweat dynamics and sweat chemistry in the context of sports performance and healthcare diagnostics. This paper presents a collection of advances in biochemical sensors and microfluidic designs that support multimodal operation in the monitoring of physiological signatures directly correlated to physical and mental stresses. These wireless, battery-free, skin-interfaced devices combine lateral flow immunoassays for cortisol, fluorometric assays for glucose and ascorbic acid (vitamin C), and digital tracking of skin galvanic responses. Systematic benchtop evaluations and field studies on human subjects highlight the key features of this platform for the continuous, noninvasive monitoring of biochemical and biophysical correlates of the stress state.
Collapse
|
43
|
Yokus MA, Agcayazi T, Traenkle M, Bozkurt A, Daniele MA. Wearable Sweat Rate Sensors. 2020 IEEE SENSORS 2020. [DOI: 10.1109/sensors47125.2020.9278818] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
44
|
Zhang Y, Chen Y, Huang J, Liu Y, Peng J, Chen S, Song K, Ouyang X, Cheng H, Wang X. Skin-interfaced microfluidic devices with one-opening chambers and hydrophobic valves for sweat collection and analysis. LAB ON A CHIP 2020; 20:2635-2645. [PMID: 32555915 DOI: 10.1039/d0lc00400f] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Soft, skin-interfaced microfluidic platforms are capable of capturing, storing, and assessing sweat chemistry and total sweat loss, which provides essential insight into human physiological health. However, sweat loss from the outlet of the microfluidic devices often leads to deviation of the measured concentration of the biomarker or electrolyte from the actual value. Here, we introduce hydrophobic valves at the junction of the chamber and the microfluidic channel as a new chamber design to reduce sweat evaporation. Because the advancing front of the liquid in the hydrophilic microchannel is blocked by the hydrophobic valve, the fluid flows into the chambers, forms the initial meniscus, and completely fills the chambers along the initial meniscus. Fluid dynamic modeling and numerical simulations provide critical insights into the sweat sampling mechanism into the chambers. With significantly reduced evaporation and contamination, the sweat sample can be easily stored for a long time for later analysis when in situ analysis is limited. Additionally, the design with multiple chambers can allow sequential generation of sweat collection at different times for long-term analysis. The in situ real-time measurements of the sweat loss and pH value analysis from the human subject demonstrate the practical utility of the devices in collecting, storing, and analyzing the sweat generated from sweat glands on the skin.
Collapse
Affiliation(s)
- Yingxue Zhang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, Hunan 411105, China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Wen F, Sun Z, He T, Shi Q, Zhu M, Zhang Z, Li L, Zhang T, Lee C. Machine Learning Glove Using Self-Powered Conductive Superhydrophobic Triboelectric Textile for Gesture Recognition in VR/AR Applications. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2000261. [PMID: 32714750 PMCID: PMC7375248 DOI: 10.1002/advs.202000261] [Citation(s) in RCA: 119] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 02/22/2020] [Indexed: 05/18/2023]
Abstract
The rapid progress of Internet of things (IoT) technology raises an imperative demand on human machine interfaces (HMIs) which provide a critical linkage between human and machines. Using a glove as an intuitive and low-cost HMI can expediently track the motions of human fingers, resulting in a straightforward communication media of human-machine interactions. When combining several triboelectric textile sensors and proper machine learning technique, it has great potential to realize complex gesture recognition with the minimalist-designed glove for the comprehensive control in both real and virtual space. However, humidity or sweat may negatively affect the triboelectric output as well as the textile itself. Hence, in this work, a facile carbon nanotubes/thermoplastic elastomer (CNTs/TPE) coating approach is investigated in detail to achieve superhydrophobicity of the triboelectric textile for performance improvement. With great energy harvesting and human motion sensing capabilities, the glove using the superhydrophobic textile realizes a low-cost and self-powered interface for gesture recognition. By leveraging machine learning technology, various gesture recognition tasks are done in real time by using gestures to achieve highly accurate virtual reality/augmented reality (VR/AR) controls including gun shooting, baseball pitching, and flower arrangement, with minimized effect from sweat during operation.
Collapse
Affiliation(s)
- Feng Wen
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| | - Zhongda Sun
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| | - Tianyiyi He
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| | - Qiongfeng Shi
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| | - Minglu Zhu
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| | - Zixuan Zhang
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| | - Lianhui Li
- i‐Lab Suzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of Sciences (CAS)Suzhou215123China
| | - Ting Zhang
- i‐Lab Suzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of Sciences (CAS)Suzhou215123China
| | - Chengkuo Lee
- Department of Electrical & Computer EngineeringNational University of Singapore4 Engineering Drive 3Singapore117576Singapore
- National University of Singapore Suzhou Research Institute (NUSRI)Suzhou Industrial ParkSuzhou215123China
- Center for Intelligent Sensors and MEMSNational University of Singapore5 Engineering Drive 1Singapore117608Singapore
- Hybrid Integrated Flexible Electronic Systems (HIFES)5 Engineering Drive 1Singapore117608Singapore
| |
Collapse
|
46
|
Shay T, Saha T, Dickey MD, Velev OD. Principles of long-term fluids handling in paper-based wearables with capillary-evaporative transport. BIOMICROFLUIDICS 2020; 14:034112. [PMID: 32566070 PMCID: PMC7286699 DOI: 10.1063/5.0010417] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Accepted: 05/11/2020] [Indexed: 05/24/2023]
Abstract
We construct and investigate paper-based microfluidic devices, which model long-term fluid harvesting, transport, sensing, and analysis in new wearables for sweat analysis. Such devices can continuously wick fluid mimicking sweat and dispose of it on evaporation pads. We characterize and analyze how the action of capillarity and evaporation can cooperatively be used to transport and process sweat mimics containing dissolved salts and model analytes. The results point out that non-invasive osmotic extraction combined with paper microfluidics and evaporative disposal can enable sweat collection and monitoring for durations longer than 10 days. We model the fluid flow in the new capillary-evaporative devices and identify the parameters enabling their long-term operation. We show that the transport rates are sufficiently large to handle natural sweat rates, while we envision that such handling can be interfaced with osmotic harvesting of sweat, a concept that we demonstrated recently. Finally, we illustrate that the salt film deposited at the evaporation pad would eventually lead to cessation of the process but at the same time will preserve a record of analytes that may be used for long-term biomarker monitoring in sweat. These principles can be implemented in future platforms for wearable skin-interfacing assays or electronic biomarker monitors.
Collapse
Affiliation(s)
- Timothy Shay
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695-7905, USA
| | - Tamoghna Saha
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695-7905, USA
| | - Michael D. Dickey
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695-7905, USA
| | - Orlin D. Velev
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695-7905, USA
| |
Collapse
|
47
|
Xie Z, Avila R, Huang Y, Rogers JA. Flexible and Stretchable Antennas for Biointegrated Electronics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e1902767. [PMID: 31490582 DOI: 10.1002/adma.201902767] [Citation(s) in RCA: 81] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 06/16/2019] [Indexed: 05/24/2023]
Abstract
Combined advances in material science, mechanical engineering, and electrical engineering form the foundations of thin, soft electronic/optoelectronic platforms that have unique capabilities in wireless monitoring and control of various biological processes in cells, tissues, and organs. Miniaturized, stretchable antennas represent an essential link between such devices and external systems for control, power delivery, data processing, and/or communication. Applications typically involve a demanding set of considerations in performance, size, and stretchability. Some of the most effective strategies rely on unusual materials such as liquid metals, nanowires, and woven textiles or on optimally configured 2D/3D structures such as serpentines and helical coils of conventional materials. In the best cases, the performance metrics of small, stretchable, radio frequency (RF) antennas realized using these strategies compare favorably to those of traditional devices. Examples range from dipole, monopole, and patch antennas for far-field RF operation, to magnetic loop antennas for near-field communication (NFC), where the key parameters include operating frequency, Q factor, radiation pattern, and reflection coefficient S11 across a range of mechanical deformations and cyclic loads. Despite significant progress over the last several years, many challenges and associated research opportunities remain in the development of high-efficiency antennas for biointegrated electronic/optoelectronic systems.
Collapse
Affiliation(s)
- Zhaoqian Xie
- Departments of Civil and Environmental Engineering, Mechanical Engineering, and Materials Science and Engineering, Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
| | - Raudel Avila
- Departments of Civil and Environmental Engineering, Mechanical Engineering, and Materials Science and Engineering, Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
| | - Yonggang Huang
- Departments of Civil and Environmental Engineering, Mechanical Engineering, and Materials Science and Engineering, Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
| | - John A Rogers
- Department of Materials Science and Engineering, Biomedical Engineering, Neurological Surgery, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, Simpson Querrey Institute and Feinberg Medical School, Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
| |
Collapse
|
48
|
Li S, Ma Z, Cao Z, Pan L, Shi Y. Advanced Wearable Microfluidic Sensors for Healthcare Monitoring. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1903822. [PMID: 31617311 DOI: 10.1002/smll.201903822] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/12/2019] [Indexed: 05/24/2023]
Abstract
Wearable flexible sensors based on integrated microfluidic networks with multiplex analysis capability are emerging as a new paradigm to assess human health status and show great potential in application fields such as clinical medicine and athletic monitoring. Well-designed microfluidic sensors can be attached to the skin surface to acquire various pieces of physiological information with high precision, such as sweat loss, information regarding metabolites, and electrolyte balance. Herein, the recent progress of wearable microfluidic sensors for applications in healthcare monitoring is summarized, including analysis principles and microfabrication methods. Finally, the challenges and opportunities for wearable microfluidic sensors in practical applications are discussed.
Collapse
Affiliation(s)
- Sheng Li
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Zhong Ma
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Zhonglin Cao
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Lijia Pan
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Yi Shi
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| |
Collapse
|
49
|
Wireless battery-free body sensor networks using near-field-enabled clothing. Nat Commun 2020; 11:444. [PMID: 31974376 PMCID: PMC6978350 DOI: 10.1038/s41467-020-14311-2] [Citation(s) in RCA: 100] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Accepted: 12/20/2019] [Indexed: 11/29/2022] Open
Abstract
Networks of sensors placed on the skin can provide continuous measurement of human physiological signals for applications in clinical diagnostics, athletics and human-machine interfaces. Wireless and battery-free sensors are particularly desirable for reliable long-term monitoring, but current approaches for achieving this mode of operation rely on near-field technologies that require close proximity (at most a few centimetres) between each sensor and a wireless readout device. Here, we report near-field-enabled clothing capable of establishing wireless power and data connectivity between multiple distant points around the body to create a network of battery-free sensors interconnected by proximity to functional textile patterns. Using computer-controlled embroidery of conductive threads, we integrate clothing with near-field-responsive patterns that are completely fabric-based and free of fragile silicon components. We demonstrate the utility of the networked system for real-time, multi-node measurement of spinal posture as well as continuous sensing of temperature and gait during exercise. Though wireless near-field communication (NFC) technologies that connect wearable sensors for health monitoring have been reported, the short range of NFC readers limits sensor functionality. Here, the authors report a wireless and battery-free body sensor network with near-field-enabled clothing.
Collapse
|
50
|
Fallahi H, Zhang J, Phan HP, Nguyen NT. Flexible Microfluidics: Fundamentals, Recent Developments, and Applications. MICROMACHINES 2019; 10:E830. [PMID: 31795397 PMCID: PMC6953028 DOI: 10.3390/mi10120830] [Citation(s) in RCA: 90] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 11/26/2019] [Accepted: 11/26/2019] [Indexed: 12/20/2022]
Abstract
Miniaturization has been the driving force of scientific and technological advances over recent decades. Recently, flexibility has gained significant interest, particularly in miniaturization approaches for biomedical devices, wearable sensing technologies, and drug delivery. Flexible microfluidics is an emerging area that impacts upon a range of research areas including chemistry, electronics, biology, and medicine. Various materials with flexibility and stretchability have been used in flexible microfluidics. Flexible microchannels allow for strong fluid-structure interactions. Thus, they behave in a different way from rigid microchannels with fluid passing through them. This unique behaviour introduces new characteristics that can be deployed in microfluidic applications and functions such as valving, pumping, mixing, and separation. To date, a specialised review of flexible microfluidics that considers both the fundamentals and applications is missing in the literature. This review aims to provide a comprehensive summary including: (i) Materials used for fabrication of flexible microfluidics, (ii) basics and roles of flexibility on microfluidic functions, (iii) applications of flexible microfluidics in wearable electronics and biology, and (iv) future perspectives of flexible microfluidics. The review provides researchers and engineers with an extensive and updated understanding of the principles and applications of flexible microfluidics.
Collapse
Affiliation(s)
| | | | | | - Nam-Trung Nguyen
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia; (H.F.); (J.Z.); (H.-P.P.)
| |
Collapse
|