1
|
Ibrahim HA, Jasim HH, El Ghoul WA, Vervack V, Słoniewski J. Comparative evaluation of bilayered and monolithic endocrowns: Fracture resistance, failure mode, and stress distribution. J Mech Behav Biomed Mater 2025; 168:107033. [PMID: 40319615 DOI: 10.1016/j.jmbbm.2025.107033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2025] [Revised: 04/08/2025] [Accepted: 04/23/2025] [Indexed: 05/07/2025]
Abstract
PURPOSE To evaluate the load-to-fracture after mechanical cycling, failure mode, and stress distribution of mandibular first molars restored with monolithic lithium disilicate (LDS) endocrowns and bilayered endocrowns featuring resin-matrix ceramic endocores veneered with cemented LDS. METHODS Thirty-six mandibular first molars were divided into three groups (n = 12): Group ME (monolithic LDS), Group VE (bilayered VITA Enamic endocore with LDS veneer), and Group CE (bilayered Cerasmart endocore with LDS veneer). After endodontic treatment, standardized preparation, and CAD/CAM fabrication, restorations underwent 250,000 mechanical loading cycles under a 150 N load. Surviving specimens were tested for fracture resistance, and fracture modes were classified. Finite element analysis (FEA) assessed stress distribution. RESULTS All samples survived the load of mechanical cycling. Group VE exhibited the highest mean fracture resistance (2774.2 N), significantly higher than Groups ME (2120.8 N) and CE (1949.6 N) (p ≤ 0.05), with no significant difference between ME and CE (p > 0.05). Failure mode analysis revealed reparable fracture rates of 0 %, 33 %, and 50 % for Groups ME, VE, and CE, respectively. Fisher's Exact Test showed significantly more reparable failures in CE compared to ME (p ≤ 0.05) and no significant difference between VE and ME (p > 0.05). FEA revealed lower stress concentration in the tested bilayered models compared to the monolithic LDS model, with VE exhibiting the lowest stress concentration across the restoration complex and tooth structure. CONCLUSIONS The biomechanical performance and failure reparability of bilayered endocrowns depend on the endocore material. Endocrowns with VITA Enamic endocores exhibited the highest fracture resistance and favorable stress distribution, while Cerasmart endocores had fewer irreparable failures.
Collapse
Affiliation(s)
- Haider Ali Ibrahim
- Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, 6 St, Al Karkh, Baghdad Governorate, Iraq.
| | - Haider Hasan Jasim
- Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, 6 St, Al Karkh, Baghdad Governorate, Iraq.
| | - Wiam Ali El Ghoul
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon.
| | - Valentin Vervack
- Department of Oral Health Sciences, Reconstructive Dentistry, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
| | - Jakub Słoniewski
- CTO of HEXdent Sp. z o.o., ul. Bojkowska 35A, 44-100, Gliwice, Poland.
| |
Collapse
|
2
|
Kamel N, Habre P. Fracture Resistance of Provisional Crowns: A Finite Element Analysis of a Semi-Permanent Resin-A Pilot Study. Dent J (Basel) 2025; 13:137. [PMID: 40277467 PMCID: PMC12026018 DOI: 10.3390/dj13040137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2025] [Revised: 03/16/2025] [Accepted: 03/19/2025] [Indexed: 04/26/2025] Open
Abstract
Background/Objectives: Fracture resistance is crucial for provisional crowns, especially under high-stress conditions like bruxism. While semi-permanent materials such as Luxacrown are designed for durability, their performance under extreme occlusal forces remains uncertain. This study uses finite element analysis (FEA) to evaluate the fracture resistance of five common provisional crown materials. Methods: A standardized digital model of a maxillary first molar was developed with uniform crown thickness. Twenty models were created to assess Unifast Trad (self-curing PMMA), Luxatemp Star (bis-acryl composite), Luxacrown (semi-permanent bis-acryl), Protemp 4 (nanofilled bis-acryl), and Telio CAD (CAD/CAM PMMA). FEA simulations evaluated vertical (250 N), lateral (225 N), diagonal (400 N), and bruxism-level (800 N) forces. Stress-to-strength ratios (SSR) and Von Mises stress distributions were analyzed to evaluate material performance and failure risk. Results: Telio CAD exhibited the highest fracture resistance, maintaining SSR values below 100% across scenarios. Luxacrown and Protemp 4 performed adequately under moderate loads but showed increased stress concentrations under bruxism-level forces. Luxatemp Star followed a similar trend, whereas Unifast Trad demonstrated the lowest resistance, accumulating significant stress in all conditions. Conclusions: Material selection is key to provisional crown fracture resistance. Telio CAD showed the highest durability, while Luxacrown and Protemp 4 performed well under moderate loads but struggled under extreme forces, raising concerns about semi-permanent materials. Luxatemp Star showed similar trends, and Unifast Trad, the weakest, is best for short-term use.
Collapse
Affiliation(s)
- Nadine Kamel
- Department of Prosthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut 1107 2180, Lebanon
| | | |
Collapse
|
3
|
Robaian A, Alshehri AM, Alqhtani NR, Almudahi A, Alanazi KK, Abuelqomsan MAS, Raffat EM, Elkaffas A, Hashem Q, Soliman TA. Effect of Surface Treatments and Thermal Aging on Bond Strength Between Veneering Resin and CAD/CAM Provisional Materials. Polymers (Basel) 2025; 17:563. [PMID: 40076056 PMCID: PMC11902269 DOI: 10.3390/polym17050563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2025] [Revised: 02/15/2025] [Accepted: 02/19/2025] [Indexed: 03/14/2025] Open
Abstract
The oral environment significantly influences the esthetic appearance of CAD/CAM provisional restorative materials. Therefore, a veneering layer is required. Bonding veneering resin composites to these materials presents challenges, particularly under conditions of thermal aging. This study evaluated the impact of various surface treatments and thermal aging on the bond strength between veneering resin and CAD/CAM provisional materials. Fifty disk-shaped specimens of each CAD/CAM material (CAD-Temp, Everest C-Temp, and PEEK), measuring 10 mm in diameter and 3 mm in height, were fabricated. After being ultrasonically cleaned, specimens were embedded in acrylic resin blocks, leaving one surface exposed for surface treatments. Specimens were assigned to five groups at random. Group C: no surface treatments applied; DB: mechanically roughened with a diamond bur; DB + TC: DB group subjected to 5000 cycles of thermocycling; SB: treated with aluminum oxide airborne abrasion; SB + TC: SB group subjected to 5000 cycles of thermocycling. After the surface treatments, the primer and resin veneering composite were applied to the specimens. The shear bond strength (SBS) was calculated using a universal testing machine and the mode of failure was evaluated with an optical stereomicroscope with 40× magnification. Scanning electron microscopy evaluation was conducted to examine the surface topography of the materials' surfaces after surface treatments. C-Temp in the SB group exhibited the highest SBS values (20.38 ± 1.04 MPa), while CAD-Temp in the C group showed the lowest values (4.60 ± 0.54 MPa). PEEK recorded significantly higher SBS values in DB + TC and SB + TC groups (9.26 ± 1.07 and 12.92 ± 0.97 MPa, respectively) compared to CAD-Temp in DB + TC and SB + TC groups (6.04 ± 0.76 and 8.82 ± 0.86 MPa, respectively). C-Temp exhibited higher SBS without surface treatment (13.11± 0.55 MPa), whereas PEEK showed higher SBS after diamond bur roughening and air particle abrasion (10.87 ± 1.02 MPa, and 14.37 ± 0.98 MPa, respectively). The thermocycling significantly reduced SBS values for C-Temp in the DB + TC and SB + TC groups (11.18 ± 0.92, 15.56 ± 0.87 MPa, respectively) and CAD-Temp in the DB + TC and SB + TC (6.04 ± 0.76 MPa and 8.82 ± 0.86 MPa, respectively). Conversely, the thermocycling had no significant effect on SBS values for PEEK material in the air particle abrasion group (12.92 ± 0.97 MPa).
Collapse
Affiliation(s)
- Ali Robaian
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
| | - Abdullah Mohammed Alshehri
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
| | - Nasser Raqe Alqhtani
- Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia;
| | - Abdulellah Almudahi
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
| | - Khalid K. Alanazi
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
| | - Mohammed A. S. Abuelqomsan
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
| | - Eman Mohamed Raffat
- Prosthetic Dentistry Department, Faculty of Dentistry, Benha National University, Benha 13511, Egypt;
- Prosthetic Dentistry Department, General Zagazig Hospital, El Sharkeya 44516, Egypt
| | - Ali Elkaffas
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt
| | - Qamar Hashem
- Endodontic division-Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia;
| | - Tarek Ahmed Soliman
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.R.); (A.M.A.); (A.A.); (K.K.A.); (M.A.S.A.); (A.E.)
| |
Collapse
|
4
|
Melc T, Attin T, Eyüboğlu TF, Özcan M. Flexural Strength of Modern CAD/CAM Restoratives After Artificial Aging. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5178. [PMID: 39517453 PMCID: PMC11547040 DOI: 10.3390/ma17215178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 09/29/2024] [Accepted: 09/30/2024] [Indexed: 11/16/2024]
Abstract
Before clinical trials are initiated, studying the mechanical performance of modern CAD/CAM restorative materials exposed to aging conditions would provide insights on their performance in service. This study evaluated the impact of thermomechanical aging on various resin composite, ceramic, hybrid, and nano-filled resin composite materials after two polymerization modes. Specimens (3 × 4 × 14 mm3) were fabricated using (n = 12 per group) a universal composite (Filtek Supreme XTE photo-polymerized for either 40 s or 120 s per layer), hybrid ceramics (BRILLIANT Crios, GC Cerasmart, Lava Ultimate, VITA ENAMIC), glass ceramics (IPS e.max CAD, VITA Suprinity PC, Straumann n!ce), or feldspar ceramics (VITABLOCS Mark II, GC Initial LRF). In each group, half of the specimens underwent thermomechanical aging. A three-point bending test was applied to all specimens and the results were statistically analyzed (α = 0.05). Glass ceramics and hybrid ceramics presented higher flexural strength values than feldspar ceramics and the universal composite before and after aging (p < 0.05). Thermomechanical cycling affected the flexural strength of all materials (p < 0.05) except Lava Ultimate, Straumann n!ce, and GC Initial (p > 0.05). The highest decrease in flexural strength after aging was found in the universal composite (40 s polymerization) (p < 0.001) and Vita Enamic (p < 0.001), while the lowest decrease was in the hybrid ceramics, Cerasmart and Lava Ultimate (p < 0.05). Extending polymerization duration reduced the aging effect on the universal composite tested. Thermomechanical aging affected the flexural strength of most materials tested. Universal composites and feldspar ceramics presented similar flexural strength values.
Collapse
Affiliation(s)
- Thomas Melc
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (T.M.); (T.A.)
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (T.M.); (T.A.)
| | - Tan Fırat Eyüboğlu
- Department of Endodontics, Faculty of Dentistry, Istanbul Medipol University, 34083 Istanbul, Türkiye;
| | - Mutlu Özcan
- Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland
| |
Collapse
|
5
|
Ellakany P, Madi M, Elwan AH, Alshehri T, Aljubran H, Aly NM. Influence of CAD-CAM manufacturing methods on the accuracy and mechanical properties of implant-supported prostheses: A systematic review. J Prosthodont 2024. [PMID: 39233444 DOI: 10.1111/jopr.13933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Accepted: 08/06/2024] [Indexed: 09/06/2024] Open
Abstract
PURPOSE This systematic review aimed to provide comprehensive insights on the accuracy, fit, and mechanical characteristics of implant-supported computer-aided design and computer-aided manufacturing (CAD-CAM) prostheses, with a focus on milled and 3D-printed approaches. METHODS The research question focused on implant-supported dental prostheses, comparing different manufacturing techniques (conventional, milled, and 3D-printed) to determine the different factors affecting the mechanical properties and fit of the CAD-CAM implant-supported prosthesis. The eligibility criteria encompassed studies involving implant-supported restorations, clear reporting of manufacturing techniques, and English-language publications from the last decade. The search was conducted across three main databases, MEDLINE, Scopus, and Web of Science in September 2023. Publication details, study characteristics, and methodological details of each included study were described. RESULTS Of the initial 1964 articles, 581 met the inclusion criteria, and 104 studies were included in the final qualitative analysis. The majority of studies were conducted in the United States, Turkey, and Brazil. Fourteen studies evaluated accuracy parameters, while four studies focused on mechanical characteristics. The studies revealed variability in mechanical properties and marginal and internal fit, with fabrication methods impacting the structural integrity and stress distribution of the prostheses. CONCLUSIONS The findings suggest that digital manufacturing workflows, both milling and 3D printing, yield acceptable properties for implant-supported restorations with minimal variations in fit and accuracy. Notably, 3D printing and hybrid techniques demonstrate advantages in specific aspects like marginal fit and stress distribution. However, the milled prosthesis provided superior results in flexural strength and fracture resistance compared to conventional methods. Further research is needed to confirm these findings in clinical settings.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Amira H Elwan
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hussain Aljubran
- Department of Periodontics, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Nourhan M Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
6
|
Niem T, Hübner A, Wöstmann B. Water absorption in artificial composites: Curse or blessing? Dent Mater 2024; 40:1097-1112. [PMID: 38811272 DOI: 10.1016/j.dental.2024.05.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/22/2024] [Accepted: 05/13/2024] [Indexed: 05/31/2024]
Abstract
OBJECTIVES This study evaluated the impact of mutable water uptake on the durability of mechanical properties and the long-term reliability of artificial composites. METHODS Three resin-based CAD/CAM restorative materials (CRMs) were investigated in three-point bending tests to calculate flexural strength (FS), modulus of elasticity (ME), modulus of resilience (MR), modulus of toughness (MT), and elastic recovery (ER). All specimens (n = 180) were stored under the same conditions and tested in four subsets (n = 15 per material) that were respectively withdrawn after repeated thermocycling (5000 cycles; 5-55 °C, H2O) and repetitive drying (7 d; 37 °C, air). For every specimen, weight differences were determined per storage condition. Likewise, loss tangent data were separately recorded via dynamic mechanical analysis to reliably assess damping characteristics. RESULTS Repeated thermocycling always induced weight increase and a concurrent significant loss in all mechanical properties except for MT and ER of a polymethylmethacrylate-based CRM. Drying consistently provoked weight loss and raised mechanical properties to initial values. Weight increase, however, enhanced loss tangent values and accordingly distinct damping characteristics, whereas weight decrease markedly lowered damping properties. SIGNIFICANCE Water uptake repeatedly induced a decrease in common mechanical properties but concurrently increased damping behavior. Invertible equilibrium processes were found with no evidence for permanent material degradation.
Collapse
Affiliation(s)
- Thomas Niem
- Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, 35392 Giessen, Germany.
| | - Antje Hübner
- Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| | - Bernd Wöstmann
- Department of Prosthodontics, Justus-Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
| |
Collapse
|
7
|
Mudhaffer S, Althagafi R, Haider J, Satterthwaite J, Silikas N. Effects of printing orientation and artificial ageing on martens hardness and indentation modulus of 3D printed restorative resin materials. Dent Mater 2024; 40:1003-1014. [PMID: 38735775 DOI: 10.1016/j.dental.2024.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/29/2024] [Accepted: 05/03/2024] [Indexed: 05/14/2024]
Abstract
BACKGROUND Three-dimensional (3D) printing is increasingly used to fabricate dental restorations due to its enhanced precision, consistency and time and cost-saving advantages. The properties of 3D-printed resin materials can be influenced by the chosen printing orientation which can impact the mechanical characteristics of the final products. PURPOSE The objective of this study was to evaluate the influence of printing orientation and artificial ageing on the Martens hardness (HM) and indentation modulus (EIT) of 3D-printed definitive and temporary dental restorative resins. METHODS Disk specimens (20 mm diameter × 2 mm height) were additively manufactured in three printing orientations (0°, 45°, 90°) using five 3D-printable resins: VarseoSmile Crownplus (VCP), Crowntec (CT), Nextdent C&B MFH (ND), Dima C&B temp (DT), and GC temp print (GC). The specimens were printed using a DLP 3D-printer (ASIGA MAX UV), while LavaTM Ultimate (LU) and Telio CAD (TC) served as milled control materials. Martens hardness (HM) and indentation modulus (EIT) were tested both before and after storage in distilled water and artificial saliva for 1, 30, and 90 days at 37 °C. RESULTS 90° printed specimens exhibited higher HM than the other orientations at certain time points, but no significant differences were observed in HM and EIT between orientations for all 3D-printed materials after 90 days of ageing in both aging media. LU milled control material exhibited the highest HM and EIT among the tested materials, while TC, the other milled control, showed similar values to the 3D printed resins. CT and VCP (definitive resins) and ND displayed higher Martens parameters compared to DT and GC (temporary resins). The hardness of the 3D-printed materials was significantly impacted by artificial ageing compared to the controls, with ND having the least hardness reduction percentage amongst all 3D-printed materials. The hardness reduction percentage in distilled water and artificial saliva was similar for all materials except for TC, where higher reduction was noted in artificial saliva. SIGNIFICANCE The used 3D printed resins cannot yet be considered viable alternatives to milled materials intended for definitive restorations but are preferable for use as temporary restorations.
Collapse
Affiliation(s)
- Shaymaa Mudhaffer
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Substitutive Dental Sciences, Faculty of Dentistry, Taibah University, Madinah, Saudi Arabia.
| | - Rana Althagafi
- Substitutive Dental Sciences, Faculty of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Engineering, Manchester Metropolitan University, Manchester, UK
| | - Julian Satterthwaite
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK.
| |
Collapse
|
8
|
Gil-Pozo A, Astudillo-Rubio D, Ferrando Cascales Á, Inchingolo F, Hirata R, Sauro S, Delgado-Gaete A. Effect of gastric acids on the mechanical properties of conventional and CAD/CAM resin composites - An in-vitro study. J Mech Behav Biomed Mater 2024; 155:106565. [PMID: 38718723 DOI: 10.1016/j.jmbbm.2024.106565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/28/2024]
Abstract
OBJECTIVES Dental erosion in patients with gastroesophageal reflux disease (GERD) is a current and frequent condition that may compromise the mechanical properties and clinical durability of resin-based composites (RBCs). This study assessed the mechanical properties of conventional and computer-aided design/computer-aided manufacturing (CAD/CAM) RBCs subsequent to simulated gastric acid aging. MATERIALS AND METHOD Three conventional and three CAD/CAM composites were assessed. They were divided into an experimental group (exposed to simulated gastric acid aging) and a control group (no aging). Both groups were analyzed for Vickers microhardness (VHN), wear and flexural strength over a period of six months. The failure rate probability for each RBC was calculated through the Weibull cumulative distribution function (m). Statistical analysis was conducted using repeated measures ANOVA, 3-way ANOVA, a non-parametric Kruskal-Wallis and U Mann-Whitney tests (α = 0.05). RESULTS The mechanical properties of all the RBCs dropped significantly after aging (p < 0.05). Lower VHN and flexural strength values, along with greater wear values were evident in the experimental groups, though the effects of the treatment varied between RBCs. The Weibull m of all the RBCs decreased over time. CONCLUSION Conventional RBCs might show greater reduction in mechanical properties compared to CAD/CAM RBCs when exposed to gastric acid attack. Thus, CAD/CAM composites may represent a suitable choice for the treatment of patients presenting erosive issues.
Collapse
Affiliation(s)
- Alexandra Gil-Pozo
- Division of Prosthodontics, School of Dentistry, Universidad Católica de Cuenca, 010107, Cuenca, Ecuador.
| | - Daniela Astudillo-Rubio
- Division of Prosthodontics, School of Dentistry, Universidad Católica de Cuenca, 010107, Cuenca, Ecuador.
| | - Álvaro Ferrando Cascales
- Department of Biomaterials Engineering, Faculty of Medicine, UCAM, Universidad Católica de Murcia, Campus de los Jerónimos, 135 Guadalupe, 30107, Murcia, Spain.
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124, Bari, Italy.
| | - Ronaldo Hirata
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, 10010, USA.
| | - Salvatore Sauro
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo ss/n, Alfara del Patriarca, 46115, Valencia, Spain.
| | - Andrés Delgado-Gaete
- Division of Prosthodontics, School of Dentistry, Universidad Católica de Cuenca, 010107, Cuenca, Ecuador.
| |
Collapse
|
9
|
Chen Y, Bai X, Xu M, Zhou T, Loh YM, Wang C, Pow EHN, Tsoi JKH. The mechanical, wear, antibacterial properties and biocompatibility of injectable restorative materials under wet challenge. J Dent 2024; 146:105025. [PMID: 38697507 DOI: 10.1016/j.jdent.2024.105025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/08/2024] [Accepted: 04/24/2024] [Indexed: 05/05/2024] Open
Abstract
OBJECTIVES To evaluate the mechanical, wear, antibacterial properties, and biocompatibility of injectable composite materials. METHODS Two injectable composite resins (GU and BI), one flowable composite resin (FS), and one flowable compomer (DF), in A2 shade, were tested. Mechanical properties were tested via three-point bending test immediately after preparation and after 1-day, 7-day, 14-day, and 30-day water storage. Under water-PMMA slurry immersion, specimens were subjected to a 3-body wear test (10,000 cycles) against stainless steel balls, while the roughness, wear depth, and volume loss were recorded. After 1-day and 3-day MC3T3-E1 cell culture, cell viability was evaluated with CCK-8 test kits, while the cell morphology was observed under CLSM and SEM. Antibacterial properties on S. mutans were assessed via CFU counting, CLSM, and SEM observation. SPSS 26.0 was used for statistical analysis (α = 0.05). RESULTS The mechanical properties were material-dependent and sensitive to water storage. Flexural strength ranked GU > FS > BI > DF at all testing levels. Three nanocomposites had better wear properties than DF. No significant difference on 1-day cell viability was found, but DF showed significantly lower cell proliferation than nanocomposites on 3-day assessment. GU and FS had more favourable cell adhesion and morphology. CFU counting revealed no significant difference, while FS presented a slightly thicker biofilm and BI showed relatively lower bacteria density. CONCLUSIONS Injectable nanocomposites outperformed the compomer regarding mechanical properties, wear resistance, and biocompatibility. The tested materials presented comparable antibacterial behaviours. Flowable resin-based composites' performances are affected by multiple factors, and their compositions can be attributed. CLINICAL SIGNIFICANCE A profound understanding of the mechanical, wear, and biological properties of the restorative material is imperative for the clinical success of dental restorations. The current study demonstrated superior properties of highly filled injectable composite resins, which imply their wider indications and better long-term clinical performances.
Collapse
Affiliation(s)
- Yanning Chen
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Xuedong Bai
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Mengxiao Xu
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Tianyu Zhou
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Yee Man Loh
- State Key Laboratory of Ultra-precision Machining Technology, Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Chunjin Wang
- State Key Laboratory of Ultra-precision Machining Technology, Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - James Kit Hon Tsoi
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China.
| |
Collapse
|
10
|
Suksawat N, Angwaravong O, Angwarawong T. Fracture resistance and fracture modes in endodontically treated maxillary premolars restored using different CAD-CAM onlays. J Prosthodont Res 2024; 68:290-298. [PMID: 37225522 DOI: 10.2186/jpr.jpr_d_22_00311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
PURPOSE To examine the fracture resistance and fracture modes of endodontically treated teeth (ETT) restored using onlays of different materials fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM). METHODS Sixty maxillary first premolars were randomly assigned to six groups (n=10). The first group comprised intact teeth (INT). The remaining premolars were prepared for mesio-occluso-distal cavity and root canal treatments. Group 2 was treated using polymer-reinforced zinc oxide-eugenol intermediate restorative material (IRM). Groups 3-6 were core build-up, prepared for onlay, and restored using resin nanoceramic (Cerasmart [CER]), polymer-infiltrated ceramic networks (Vita Enamic [VE]), lithium disilicate-based ceramic (IPS e.max CAD [EM]), or translucent zirconia (Katana Zirconia UTML [KZ]). All specimens were immersed in 37 °C distilled water for 24 h. Each specimen was loaded at 45° to the long axis until failure (crosshead speed, 0.5 mm/min). Fracture loads were analyzed using one-way analysis of variance and Tukey's post-hoc test (α=0.05). RESULTS There were no significant differences in fracture load among the INT, CER, VE, and EM groups. The fracture load in the KZ group was significantly higher than those in the other groups (P < 0.05). Fracture load was the lowest in the IRM group (P < 0.05). The unrestorable failure rate was 70% in the KZ group and 10-30% in the other experimental groups. CONCLUSIONS ETT restored using Cerasmart, Vita Enamic, or IPS e.max CAD onlays had fracture resistance and patterns comparable to those of intact teeth. Katana Zirconia UTML-restored ETT had the highest fracture load but also a higher unrestorable failure rate.
Collapse
Affiliation(s)
- Nuntana Suksawat
- Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Onauma Angwaravong
- Division of Pediatric Dentistry, Department of Preventive Dentistry, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Thidarat Angwarawong
- Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
11
|
Temizci T, Bozoğulları HN. Effect of thermocycling on the mechanical properties of permanent composite-based CAD-CAM restorative materials produced by additive and subtractive manufacturing techniques. BMC Oral Health 2024; 24:334. [PMID: 38486195 PMCID: PMC10938812 DOI: 10.1186/s12903-024-04016-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 02/12/2024] [Indexed: 03/18/2024] Open
Abstract
BACKGROUND The aim of the study was to determine and compare the biaxial flexural strength (BFS) and Vickers hardness (VHN) of additive and subtractive manufactured permanent composite-based restorative materials, before and after thermal aging. METHODS A total of 200 specimens were prepared; 100 disc-shaped specimens (diameter 13 × 1.2 mm) for the BFS test and 100 square specimens (14 × 14 × 2 mm) for the VHN test. The specimens were made from various materials: two subtractive composite-based blocks (Cerasmart 270 [CS], Vita Enamic [VE]), two additive composite-based resins used for two different vat polymerization methods (digital light processing [DLP]; Saremco Print Crowntec [SC] and stereolithography [SLA]; Formlabs Permanent Crown Resin [FP]), and one feldspathic glass-matrix ceramic block (Vita Mark II [VM]) as the control group. Specimens of each material were divided into two subgroups: thermal cycled or non-thermal cycled (n = 10). BFS and VHN tests were performed on all groups. Data were analyzed with two-way ANOVA and post hoc Tukey test (α = 0.05). RESULTS The type of restorative material used for the specimen had a statistically significant influence on both BFS and VHN values. However, thermal cycling did not affect the BFS and VHN values. After thermal cycling, the results of the BFS test were ranked from best to worst as follows: CS, FP, SC, VE, then VM. For the VHN values, the order from best to worst was as follows: VM, VE, CS, FP, then SC. CONCLUSIONS 3D printed and milled composite groups showed higher BFS than feldspathic ceramics. When the VHN results were examined, it was seen that the 3D resin groups had the lowest VHN values. Furthermore, it was observed that the thermal cycle had no effect on BFS or VHN.
Collapse
Affiliation(s)
- Tuğba Temizci
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey.
| | - Hatice Nalan Bozoğulları
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey
| |
Collapse
|
12
|
Lukomska-Szymanska M, Radwanski M, Kharouf N, Mancino D, Tassery H, Caporossi C, Inchingolo F, de Almeida Neves A, Chou YF, Sauro S. Evaluation of Physical-Chemical Properties of Contemporary CAD/CAM Materials with Chromatic Transition "Multicolor". MATERIALS (BASEL, SWITZERLAND) 2023; 16:4189. [PMID: 37297323 PMCID: PMC10254467 DOI: 10.3390/ma16114189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/31/2023] [Accepted: 06/03/2023] [Indexed: 06/12/2023]
Abstract
The use of materials for computer-aided design/computer-aided manufacturing (CAD/CAM) has been rapidly increasing in daily practice. However, one of the main issues regarding modern CAD/CAM materials is their aging in the oral environment, which may lead to significant changes in their overall properties. The aim of this study was to compare the flexural strength, water sorption, cross-link density (softening ratio%), surface roughness, and SEM analysis of three modern CAD/CAM "multicolor" composites. Grandio (Grandio disc multicolor-VOCO GmbH, Cuxhaven, Germany), Shofu (Shofu Block HC-Shofu Inc., Kyoto, Japan), and Vita (Vita Enamic multiColor-Vita Zahnfabrik, Bad Sackingen, Germany) were tested in this study. They were prepared in stick-shaped specimens and submitted to different tests after several aging protocols, such as thermocycling and mechanical cycle loading challenge. Further disc-shaped specimens were also created and tested for water sorption, cross-link density, surface roughness, and SEM ultramorphology, before and after storage in an ethanol-based solution. For flexural strength and ultimate tensile strength, Grandio showed the greatest values both at baseline and after aging (p < 0.05). Grandio and Vita Enamic presented the highest modulus of elasticity and the lowest water sorption (p < 0.05). A significant reduction (p < 0.05) in microhardness after ethanol storage (softening ratio%) was observed especially in Shofu. Grandio had the lowest roughness parameters compared to the other tested CAD/CAM materials, while ethanol storage significantly increased the Ra and RSm values in Shofu (p < 0.05). Despite the comparable modulus of elasticity of Vita and Grandio, this latter showed greater flexural strength and ultimate tensile strength both at baseline and after aging. Hence, Grandio and Vita Enamic may be employed for the anterior teeth and for those restorations requiring load-bearing capacity. Conversely, aging seems to affect several properties of Shofu, so its use for permanent restorations should be well-pondered based on the clinical situation.
Collapse
Affiliation(s)
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 251 Pomorska Str., 92-213 Lodz, Poland;
| | - Naji Kharouf
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Davide Mancino
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Herve Tassery
- Ecole de Médecine Dentaire de Marseille, Université d’Aix-Marseille, 13385 Marseille, France
- Laboratoire Bioinginierie et Nanoscience, LBN, Université de Montpellier, 545 Pr JL Viala, 34090 Montpellier, France
| | | | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Aline de Almeida Neves
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-853, Brazil
| | - Yu Fu Chou
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| | - Salvatore Sauro
- Independent Researcher, Roma, 65B, 00030 Labico, Italy
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| |
Collapse
|
13
|
Soliman TA, Robaian A, Al-Gerny Y, Hussein EMR. Influence of surface treatment on repair bond strength of CAD/CAM long-term provisional restorative materials: an in vitro study. BMC Oral Health 2023; 23:342. [PMID: 37254207 DOI: 10.1186/s12903-023-03021-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 05/05/2023] [Indexed: 06/01/2023] Open
Abstract
BACKGROUND The surface treatment to improve the repair bond strength may vary because CAD/CAM provisional restoration polymers exhibit a variety of microstructures. This study was conducted to evaluate the effect of surface treatments on the repairability of three different CAD/CAM polymers for long-term provisional restorations. METHODS Thirty specimens from each provisional restorative materials (CAD-Temp, Everest C-Temp, and PEEK) were divided into three groups: C: surfaces received no treatment; SB: surfaces were airborne particle abraded with 50 μm aluminum oxide; SB-T: surfaces received the same conditions as group SB in addition to thermocycling before and after treatment. Primer and nanohybrid repair resin composite were applied to the prepared CAD /CAM surfaces. The shear bond strength and the mode of failure were assessed. ANOVA and Tukey's significant difference tests were used to evaluate the data. RESULTS The SB group had significantly higher repair SBS values (p < .001) compared to the other groups (C and SB-T). Everest C-Temp significantly recorded the highest repair SBS (17.84 ± 0.19 MPa) in group SB, while the lowest repair SBS values (5.51 ± 1.14 MPa) for CAD-Temp were recorded in group C. PEEK significantly recorded the second highest repair SBS (15.96 ± 0.18) in the SB group. CONCLUSIONS Everest C-Temp had the highest repair SBS after an airborne abrasion particle. Thermocycling had no significant effect on the repair SBS for PEEK. Everest C-Temp and PEEK are recommended as long-term durable provisional materials for clinical use.
Collapse
Affiliation(s)
- Tarek Ahmed Soliman
- Dental Biomaterials Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
- Prosthetic Dentistry Department, Faculty of Dentistry, New Mansoura University, Mansoura, Egypt.
| | - Ali Robaian
- Conservative Dental Science Department, Faculty of Dentistry, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia
| | - Youssef Al-Gerny
- Restorative Dental Science Department, Faculty of Dentistry, King Khalid University, Abha, KSA, Saudi Arabia
| | - Eman Mohamed Raffat Hussein
- Prosthetic Dentistry Department, General Zagazig Hospital, El Sharkeya, Egypt
- Prosthetic Dentistry Department, Faculty of Dentistry, Misr International University, Obour, Greater Cairo, Egypt
| |
Collapse
|
14
|
Emam M, Arafa AM. Stress distribution and fracture resistance of green reprocessed polyetheretherketone (PEEK) single implant crown restorations compared to unreprocessed PEEK and Zirconia: an in-vitro study. BMC Oral Health 2023; 23:275. [PMID: 37170111 PMCID: PMC10173503 DOI: 10.1186/s12903-023-02943-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 04/05/2023] [Indexed: 05/13/2023] Open
Abstract
BACKGROUND It is unclear which crown materials are optimum to disperse the generated stresses around dental implants. The objective of this study is to assess stress distribution and fracture resistance of green reprocessed Polyetheretherketone (PEEK) in comparison to un-reprocessed PEEK and zirconia single implant crown restorations. METHODS Twenty crowns (n = 20) were obtained, five from zirconia and fifteen from pressed PEEK that were subdivided into 3 groups of five specimens each (n = 5) according to weight% of reprocessed material used. A 100% new PEEK was used for the first group, 50% new and 50% reprocessed PEEK were used for the second group, and a 100% reprocessed PEEK was used for the third group. Epoxy resin model with dental implant in the second mandibular premolar was constructed with strain gauges located mesially and distally to the implant to record strain while a load of 100 N was applied with 0.5 mm/min then specimens of all groups were vertically loaded till failure in a universal testing machine at cross head speed 1 mm/min. Data was statistically analyzed by using One-way Analysis of Variance (ANOVA) followed by Post-hoc test when ANOVA test is significant. RESULTS No significant difference between strain values of tested groups (p = 0.174) was noticed. However, a significant difference between fracture resistance values was noticed where the zirconia group recorded a significantly higher value (p < 0.001). CONCLUSIONS Implant restorative materials with different moduli of elasticity have similar effects regarding stresses distributed through dental implant and their surrounding bone. Reprocessed PEEK implant restorations transmit similar stresses to dental implant and surrounding bone as non-reprocessed PEEK and zirconia restorations. Zirconia failed at higher load values than all tested PEEK restorations but all can be safely used in the posterior area as crown restorations for single implants. CLINICAL RELEVANCE Applying "green dentistry" principles may extend to include reprocessing of pressed PEEK restorative materials without affecting the material's shock absorption properties.
Collapse
Affiliation(s)
- Marwa Emam
- Fixed Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity St, El-Qobba Bridge, Al Waili, 11566, Cairo, Egypt.
| | - Ahmed Mohamed Arafa
- Fixed Prosthodontics Department, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
| |
Collapse
|
15
|
Dapieve KS, Pilecco RO, Temp RW, Villetti MA, Pereira GKR, Valandro LF. Adhesion to lithium disilicate glass-ceramics after aging: Resin viscosity and ceramic surface treatment effects. J Mech Behav Biomed Mater 2023; 142:105819. [PMID: 37062098 DOI: 10.1016/j.jmbbm.2023.105819] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 03/26/2023] [Accepted: 03/30/2023] [Indexed: 04/08/2023]
Abstract
OBJECTIVE To evaluate the influence of intaglio ceramic surface treatments, resin cement viscosities, and storage regimens on the microshear bond strength of lithium disilicate ceramic. In addition, to investigate the dynamic viscosity of the resin-based luting agents. MATERIALS AND METHODS Ceramic slices were randomly allocated into eight groups (n = 19) considering three factors: ceramic surface treatment (hydrofluoric acid followed by silane, HF; or self-etching ceramic primer, E&P), resin cement viscosity (high, HIGH; or low, LOW) and storage regimen (baseline or aging). Surface treatments were performed, resin cement cylinders were built and microshear bond strength tests (μSBS, wire-loop method, speed: 1.0 mm/min) were run according to the storage factor. Failure mode, topographic and dynamic viscosity (37 °C; shear rate of 1.0-100 s-1) of resin cement components (base, high and low catalyst) were also performed. RESULTS Resin cement viscosity and the association among ceramic surface treatment, resin cement viscosity, and storage regimen were statistically significant factors (p < 0.05). Worse behavior was identified for the E&P_HIGH group compared to the E&P_LOW and HF_LOW in the baseline condition. After aging, the HF_HIGH group (16.78 MPa) presented the worst result among the aged groups (21.44-25.25 MPa). Most of the failures were adhesive. Surface micrographs revealed a distinct pattern after etching, more aggressive by HF and milder by E&P. High viscosity catalyst is 5.3 and 8.5-fold more viscous than the base and low viscosity catalyst, respectively (high > base > low). CONCLUSION Differences in filler content can impact the resin viscosity of the material (more fillers increase the viscosity), which in turn can influence the bond strength of a lithium disilicate ceramic, depending on the surface treatment and storage regimen.
Collapse
|
16
|
Muhammed HA, Mahmoud EM, Fahmy AE, Nasr DM. The effect of sandblasting versus acid etching on the surface roughness and biaxial flexural strength of CAD/CAM resin-matrix ceramics (In vitro study). BMC Oral Health 2023; 23:169. [PMID: 36964539 PMCID: PMC10039528 DOI: 10.1186/s12903-023-02883-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 03/14/2023] [Indexed: 03/26/2023] Open
Abstract
BACKGROUND CAD/CAM resin matrix ceramics are one of the materials used in dental offices. The long-term success of the restoration depends on the bond strength of the restoration to the tooth and other materials; thus, surface treatment of the restoration is necessary to achieve this. But such treatment may affect the restoration strength. The purpose of this study is to assess the impact of various surface treatments on the surface roughness (Ra) and the biaxial flexural strength of two CAD-CAM resin-matrix ceramics. METHODS Thirty-six-disc-shaped specimens, each measuring 1.2 mm in thickness and 12 mm in diameter, were machined from two resin-matrix ceramic blocks (Lava Ultimate and Cerasmart) (n = 18). Based on the surface treatments, each material was divided into 3 groups: control (no treatment), 50-μm Al2O3 sandblasting, or 9% hydrofluoric acid etching (n = 6). The surface roughness (Ra) was evaluated by the 3D laser scanning microscope. Then, specimens were aged by thermal cycling (5000 cycles) and tested for biaxial flexural strength using a universal testing machine at a crosshead speed of 1.0 mm/min. RESULTS No significant differences in flexural strength or Ra were found for Lava Ultimate among the surface treatment groups. For Cerasmart, only the sandblasting group showed significantly higher Ra values than the control group. Also, the Ra values for the sandblasting group were significantly higher than those for the acid etching group. The flexural strengths of the sandblasting and acid etching groups for Cerasmart were statistically similar, and both were significantly lower than the control group. CONCLUSIONS Although all of the applied surface conditioning techniques improved Ra, they had a negative impact on the flexural strength of resin-matrix ceramics. Thus, clinicians should utilize the appropriate surface treatment techniques, taking into account their effects on the surface roughness and mechanical properties of resin-matrix ceramics.
Collapse
Affiliation(s)
- Heba A Muhammed
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Elsayed M Mahmoud
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Amal E Fahmy
- Dental Biomaterials Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Dina M Nasr
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
17
|
Dapieve KS, Velho HC, da Rosa LS, Pivetta JP, Maidana FC, Venturini AB, Kleverlaan CJ, Pereira GKR, Valandro LF. Ceramic surface conditioning, resin cement viscosity, and aging relationships affect the load-bearing capacity under fatigue of bonded glass-ceramics. J Mech Behav Biomed Mater 2023; 139:105667. [PMID: 36657192 DOI: 10.1016/j.jmbbm.2023.105667] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/09/2023]
Abstract
This study aimed to evaluate the influence of ceramic surface treatments, resin cement viscosities, and storage regimens on the fatigue performance of bonded glass-ceramics (lithium disilicate, LD; feldspathic, FEL). Ceramic discs (Ø = 10 mm; thickness = 1.5 mm) were allocated into eight groups per ceramic (n = 15), considering three factors: "ceramic surface treatment" in two levels - 5% hydrofluoric acid etching and silane-based coupling agent application (HF), or self-etching ceramic primer (E&P); "resin cement viscosity" in two levels - in high or low viscosity; and "storage regimen" in two levels - baseline, 24 h to 5 days; or aging, 180 days + 25,000 thermal cycles. Adhesive luting was performed onto glass fiber-reinforced epoxy resin discs (Ø = 10 mm; thickness = 2 mm) and the bonded assemblies were subjected to cyclic fatigue tests: initial load = 200 N; step-size = 25 N (FEL) and 50 N (LD); 10,000 cycles/step; 20 Hz. Scanning electron microscopy (SEM) inspections were performed. Regarding the LD ceramic, the fatigue behavior was reduced after aging for HF_HIGH and E&P_LOW conditions, while stable performance was observed for HF_LOW and E&P_HIGH. Regarding the FEL results, aging negatively affected HF_HIGH, E&P_HIGH, and E&P_LOW, being that only the HF_LOW condition presented a stable behavior. The failure initiated from defects on the etched surface of the ceramics, where the cross-sectional analysis commonly revealed unfilled areas. Long-term aging might induce a decrease in mechanical behavior. The 'ceramic microstructure/surface conditioning/resin cement viscosity relationships' modulate the fatigue performance of lithium disilicate and feldspathic glass-ceramics.
Collapse
Affiliation(s)
- Kiara Serafini Dapieve
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Helder Callegaro Velho
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Jordana Pavanelo Pivetta
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Cocco Maidana
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andressa Borin Venturini
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North-Holland, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
18
|
Effect of aging on color, gloss and surface roughness of CAD/CAM composite materials. J Dent 2023; 130:104423. [PMID: 36642325 DOI: 10.1016/j.jdent.2023.104423] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/17/2022] [Accepted: 01/11/2023] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVES To assess the effect of aging procedures on color, gloss and surface roughness of CAD/CAM composite materials. METHODS 6 CAD/CAM composite materials (Brilliant CRIOS, Cerasmart, Lava Ultimate, Tetric CAD, Shofu Block HC, Grandio Blocs) were tested. 10 CAD/CAM fabricated specimens of each material polished according to manufacturers' recommendations, were subjected to one of the following aging procedures; immersion in coffee (30 days, 37οC), water thermocycling (5000 cycles, 5-55 °C) and photoaging (150,000 kJ/m2). Color, gloss and surface roughness measurements were performed before and after aging and the respective changes were calculated. Kruskal-Wallis tests, paired t-tests, one-way ANOVA and Bonferroni post-hoc tests were used for statistical analysis (a = 0.05). RESULTS Color changes ranged from 3.03 to 4.13 after coffee immersion, from 1.33 to 2.55 after thermocycling and from 1.02 to 2.75 after photoaging. No statistically significant differences for ΔE*ab were found among materials after coffee immersion and thermocycling (p>0.05). Gloss changes ranged from -5.7 to -1.6 GU after coffee immersion, from -2.3 to 0.1 GU after thermocycling and from -4.4 to 0.5 GU after photoaging. No significant differences in gloss changes were found among materials after aging (p>0.05). Tetric CAD demonstrated the significantly lower gloss and the higher surface roughness after polishing. Except for gloss after thermocycling, aging procedures caused significant alteration of gloss and surface roughness parameters from baseline levels. CONCLUSIONS Aging procedures caused perceptible but acceptable color changes and small but visible gloss changes, while surface roughness parameters of the tested CAD/CAM composite materials were significantly affected by aging. CLINICAL SIGNIFICANCE Aging procedures affected CAD/CAM composite materials indicating that these materials may be prone to color and surface alterations in the oral environment that could compromise the esthetics and the performance of the restorations. Clinical studies are needed to investigate the long-term behavior of the newly introduced CAD/CAM materials.
Collapse
|
19
|
Gad MM, Alghamdi R, Al-Ghamdi R, Al-Jefri A, Akhtar S, Khan SQ, Alalawi H, Al-Qarni FD. Wear and Fracture Resistance of 3D-Printed Denture Teeth: An In Vitro Comparative Study. J Prosthodont 2023; 32:170-177. [PMID: 35411606 DOI: 10.1111/jopr.13521] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 03/31/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE The longevity of removable prostheses is mostly influenced by the properties of the used materials. The ability of the material to withstand high occlusal loads without deformation can enhance patient satisfaction and quality of life. This in vitro study aimed to investigate the wear and fracture resistance of three-dimensional (3D)-printed teeth compared with commercially available acrylic resin teeth. MATERIALS AND METHODS A total of 40 prefabricated acrylic teeth and 40 3D-printed teeth were prepared in two forms: anatomical for fracture resistance or flat for wear resistance (n = 10). For wear evaluation, specimens were scanned at baseline and then subjected to thermal cycling (10,000 cycles). This was followed by a chewing simulator (60,000 cycles) against either metal or natural tooth. Then, the specimens were scanned again. Wear analysis was performed by superimposing the standard tessellation language (STL) files from baseline and the final scans with the aid of GOM Inspect 2020 software. Fracture resistance was assessed with a universal testing machine at a crosshead speed of 0.5 mm/min before and after thermal cycling. Data were analyzed with two-independent t-test and two-way ANOVA (α = 0.05). RESULTS The 3D-printed teeth showed significantly lower wear resistance than the prefabricated ones with both antagonists (metal, p = 0.049; natural tooth, p = 0.021). The fracture resistance of the 3D-printed teeth was significantly higher than that of the prefabricated teeth before thermocycling (p = 0.042). After thermal cycling, the fracture resistance of both groups was decreased with no significant differences between them (p = 0.266). CONCLUSIONS The 3D-printed teeth showed lower wear resistance and higher fracture resistance than the prefabricated ones. Thermal cycling negatively affected the fracture resistance of 3D-printed teeth.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Rahaf Alghamdi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Raghad Al-Ghamdi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Alaa Al-Jefri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Qadir Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Haidar Alalawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
20
|
Cyclic fatigue vs static loading for shear bond strength test of lithium disilicate and dentin substrates: A comparison of resin cement viscosities. Dent Mater 2022; 38:1910-1920. [DOI: 10.1016/j.dental.2022.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2022] [Revised: 09/22/2022] [Accepted: 09/22/2022] [Indexed: 11/16/2022]
|
21
|
Ellakany P, Fouda SM, Mahrous AA, AlGhamdi MA, Aly NM. Influence of CAD/CAM Milling and 3D-Printing Fabrication Methods on the Mechanical Properties of 3-Unit Interim Fixed Dental Prosthesis after Thermo-Mechanical Aging Process. Polymers (Basel) 2022; 14:4103. [PMID: 36236050 PMCID: PMC9572976 DOI: 10.3390/polym14194103] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/16/2022] [Accepted: 09/18/2022] [Indexed: 11/20/2022] Open
Abstract
This study assessed the influence of CAD/CAM milling and 3D-printing fabrication methods on mechanical properties of 3-unit interim fixed dental prosthesis (IFDPs) after thermo-mechanical aging. Forty 3-unit IFDPs were fabricated on a mandibular right second premolar and second molar of a typodont cast. Samples were fabricated from the following materials; auto-polymerized polymethyl methacrylate (conventional resin), CAD/CAM PMMA (milled resin) and two different CAD/CAM 3D-printed composite resins; digital light processing Asiga (DLP AS) and stereolithography NextDent (SLA ND). Mechanical properties were compared between the studied materials using Kruskal−Wallis test, followed by multiple pairwise comparisons using Bonferroni adjusted significance. There was a significant difference in flexural strength and microhardness between the studied materials (p < 0.001), with the highest mean ± SD reported in the milled IFDPs (174.42 ± 3.39, 27.13 ± 0.52), and the lowest in the conventional IFDPs (98.02 ± 6.1, 15.77 ± 0.32). Flexural strengths differed significantly between the conventional IFDPs and all materials except DLP AS. The highest elastic modulus was recorded in the milled group, and the lowest in the SLA ND group (p = 0.02). In conclusion, superior flexural strength, elastic modulus, and hardness were reported for milled IFDPs. SLA ND printed IFDPs showed comparable mechanical properties to milled ones except for the elastic modulus.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shaimaa M. Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Amr A. Mahrous
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Maram A. AlGhamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| |
Collapse
|
22
|
Influence of Artificial Aging on Mechanical Properties of Six Resin Composite Blocks for CAD/CAM Application. COATINGS 2022. [DOI: 10.3390/coatings12060837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
(1) The interactions in the oral cavity between resin composite blocks for CAD/CAM application and saliva, biofilm, and chemicals and their influence on mechanical properties are still mostly unknown. The purpose of this study is to examine the impact of artificial aging on the flexural strength, flexural modulus, hardness, Weibull modulus, and probability of failure of six resin composite CAD/CAM materials. (2) The aging was conducted by storing the specimens in water at 37 °C for 3 months, then a 3-point bending test was applied and measured. The microhardness was measured with a Vickers microhardness tester. Weibull analysis (according to ISO) was also performed. The shape and scale parameters were calculated. (3) After aging, the flexural strength values ranged from 95.51 (SD 9.07) MPa for the aged Shofu Block HC (HC) to 160.28 (SD 10.37) MPa for non-aged Gandio blocks (GR), and the flexural modulus values ranged from 7.75 (SD 0.19) GPa for HC to 16.77 (SD 0.60) GPa for GR. The microhardness (HV01) ranged from 72.71 (SD 1.43) for the Katana Avencia Block (AV) to 140.50 (SD 5.51) for GR. After aging, the Weibull characteristic strength ranged from 99.47 MPa for HC to 169.25 MPA for Brilliant Crios (CR). (4) Water storage led to a decrease in flexural strength and characteristic strength and slightly affected the flexural modulus. Gandio Blocks, Tetric CAD, and Brilliant Crios presented higher flexural strength than others.
Collapse
|
23
|
Micovic Soldatovic D, Liebermann A, Huth KC, Stawarczyk B. Fracture load of different veneered and implant-supported 4-UNIT cantilever PEEK fixed dental prostheses. J Mech Behav Biomed Mater 2022; 129:105173. [DOI: 10.1016/j.jmbbm.2022.105173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/04/2022] [Accepted: 03/07/2022] [Indexed: 11/16/2022]
|
24
|
Optical Behavior and Surface Analysis of Dental Resin Matrix Ceramics Related to Thermocycling and Finishing. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094346] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Color preservation of esthetic dental restorative materials in the oral environment represents, besides longevity, a concern, and there is still limited knowledge related to the effect of aging on the optical behavior of resin matrix ceramics. The study analyzed the finishing and thermocycling of resin matrix ceramic material surfaces, in order to assess their consequences on optical properties. Five resin matrix CAD/CAM ceramics, namely a polymer-infiltrated ceramic and four types of nanoparticle-filled resins, were selected for the study, and finished by polishing and glazing. Thermocycling was chosen as the in vitro aging method. Surface microroughness, optical and hardness evaluations were achieved before and after artificial aging. Statistical analyses were performed with IBM SPSS Statistics software at a significance value of p < 0.05. Micro-roughness values increased after thermocycling, but were kept under the clinically accepted values. The optical characteristics of resin matrix ceramics were not significantly modified by thermocycling. Values of the glazed samples became closer to those of the polished ones, after hydrothermal aging, even if the differences were insignificant. Thermocycling significantly decreased the microhardness, mainly for glazed samples. This could be the consequence of glaze removal during thermocycling, which means that glazes provide a surface protection for a limited time.
Collapse
|
25
|
Li H, Sakai T, Tanaka A, Ogura M, Lee C, Yamaguchi S, Imazato S. Interpretable AI Explores Effective Components of CAD/CAM Resin Composites. J Dent Res 2022; 101:1363-1371. [DOI: 10.1177/00220345221089251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
High flexural strength of computer-aided manufacturing resin composite blocks (CAD/CAM RCBs) are required in clinical scenarios. However, the conventional in vitro approach of modifying materials’ composition by trial and error was not efficient to explore the effective components that contribute to the flexural strength. Machine learning (ML) is a powerful tool to achieve the above goals. Therefore, the aim of this study was to develop ML models to predict the flexural strength of CAD/CAM RCBs and explore the components that affect flexural strength as the first step. The composition of 12 commercially available products and flexural strength were collected from the manufacturers and literature. The initial data consisted of 16 attributes and 12 samples. Considering that the input data for each sample were recognized as a multidimensional vector, a fluctuation range of 0.1 was proposed for each vector and the number of samples was augmented to 120. Regression algorithms—that is, random forest (RF), extra trees, gradient boosting decision tree, light gradient boosting machine, and extreme gradient boosting—were used to develop 5 ML models to predict flexural strength. An exhaustive search and feature importance analysis were conducted to analyze the effective components that affected flexural strength. The R2 values for each model were 0.947, 0.997, 0.998, 0.983, and 0.927, respectively. The relative errors of all the algorithms were within 15%. Among the high predicted flexural strength group in the exhaustive search, urethane dimethacrylate was contained in all compositions. Filler content and triethylene glycol dimethacrylate were the top 2 features predicted by all models in the feature importance analysis. ZrSiO4 was the third important feature for all models, except the RF model. The ML models established in this study successfully predicted the flexural strength of CAD/CAM RCBs and identified the effective components that affected flexural strength based on the available data set.
Collapse
Affiliation(s)
- H. Li
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - T. Sakai
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - A. Tanaka
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - M. Ogura
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - C. Lee
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - S. Yamaguchi
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - S. Imazato
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| |
Collapse
|
26
|
Schmeiser F, Arbogast F, Ruppel H, Mayinger F, Reymus M, Stawarczyk B. Methodology investigation: Impact of crown geometry, crown, abutment and antagonist material and thermal loading on the two-body wear of dental materials. Dent Mater 2021; 38:266-280. [PMID: 34953628 DOI: 10.1016/j.dental.2021.12.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 11/19/2021] [Accepted: 12/08/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVES To investigate the impact of crown geometry, crown/abutment/antagonist material and thermal loading on the two-body wear of dental materials caused by chewing simulation. MATERIALS AND METHODS For the crown geometry, crowns (polymethylmethacrylate (PMMA), polyetheretherketone (PEEK) and silicate ceramic (SiO2)) were milled with a flat, steep, or medium cusp inclination (CINC). For the crown/abutment material, crowns (PMMA, PEEK and SiO2) were combined with PMMA, polymer-infiltrated-ceramic-network (PICN), cobalt-chrome alloy (CoCr) and natural teeth (ENAM) abutments. For the antagonist material, antagonists were fabricated from PICN, CAD/CAM resin composite (RECO), steatite (STEA), steel (STL) and ENAM and tested against flat specimens (substrates) made of veneering ceramic (VC). For thermal loading, the duration (30 s, 60 s, 120 s) and presence of temperature changes (37 °C versus 5 °C/55 °C) was varied. Material losses were determined by matching scanned specimens before and after aging (400,000 chewing cycles, 50 N, 1.3 Hz). Martens parameters were determined for the antagonists/substrates. Data were analyzed using Kolmogorov-Smirnov-test, Kruskal-Wallis H, Scheffé-Post-Hoc-tests, pairwise comparisons, Bonferroni correction, one-way ANOVA, Mann-Whitney-U and Spearman rho. RESULTS PMMA crowns presented the highest and PEEK the lowest material losses. Flat CINC showed the lowest material losses for PEEK and SiO2 crowns. CoCr and ENAM abutments presented material losses in the same range. Antagonist and cumulative material losses for RECO and ENAM were similar. Thermal loading did not influence material losses. SIGNIFICANCE Crown geometry influences the crown and antagonists wear, with an increased cusp inclination entailing increased wear. For in vitro set-ups, CoCr abutments and RECO antagonists present valid alternatives to natural teeth. For polymers, in vitro chewing simulations may be performed at a constant temperature (37 °C).
Collapse
Affiliation(s)
- Felix Schmeiser
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany.
| | - Fee Arbogast
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Hendrik Ruppel
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Felicitas Mayinger
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Marcel Reymus
- Department of Conservative Dentistry and Periodontology, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital Ludwig-Maximilians-University, Goethestrasse 70, 80336 Munich, Germany
| |
Collapse
|
27
|
Thermoanalytical Investigations on the Influence of Storage Time in Water of Resin-Based CAD/CAM Materials. Biomedicines 2021; 9:biomedicines9121779. [PMID: 34944594 PMCID: PMC8698771 DOI: 10.3390/biomedicines9121779] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 11/23/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022] Open
Abstract
New resin-based composites and resin-infiltrated ceramics are used to fabricate computer-aided design (CAD) and computer-aided manufacturing (CAM)-based restorations, although little information is available on the long-term performance of these materials. The aim of this investigation was to determine the effects of storage time (24 h, 90 days, 180 days) on the thermophysical properties of resin-based CAD/CAM materials. Thermogravimetric Analysis (TGA), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were used in the study. TGA provided insight into the composition of the resin-based materials and the influence of internal plasticization and water sorption. Resin-based composites showed different decomposition, heat energy and mechanical behavior, which was influenced by storage time in water. Individual materials such as Grandio bloc showed lower influence of water storage while maintaining good mechanical properties.
Collapse
|
28
|
Taşın S, Ismatullaev A. Comparative evaluation of the effect of thermocycling on the mechanical properties of conventionally polymerized, CAD-CAM milled, and 3D-printed interim materials. J Prosthet Dent 2021; 127:173.e1-173.e8. [PMID: 34756771 DOI: 10.1016/j.prosdent.2021.09.020] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 10/19/2022]
Abstract
STATEMENT OF PROBLEM Studies on the energy absorption characteristics by means of elastic and plastic material deformation of interim materials are lacking. PURPOSE The purpose of this in vitro study was to compare the effect of different thermocycling periods on the flexural strength (σfs), resilience (Ur), and toughness (UT) of conventionally polymerized, computer-aided design and computer-aided manufacturing (CAD-CAM) milled, and 3-dimensionally (3D) printed interim materials. MATERIAL AND METHODS Rectangular specimens (n=30 for each material) were fabricated from autopolymerized polymethyl methacrylate (PMMA), bis-acryl resin (Bis-acryl), CAD-CAM polymethyl methacrylate-based polymer (CAD-CAM/Milled), and 3D-printed composite resin (3D-Printed). Each material was divided into 3 groups (n=10) according to the applied thermocycling (5 °C to 55 °C) procedure: control (0 cycles), 2500, and 10 000 cycles. Parameters of the materials such as σfs, Ur, and UT were tested in a 3-point bend test according to International Organization for Standardization (ISO) 10477. Data were statistically analyzed with the Shapiro-Wilk test followed by Kruskal-Wallis test, the Mann-Whitney U test, the Friedman test, and Wilcoxon signed-rank test (α=.05). RESULTS The tested material and thermocycling had a statistically significant influence on the σfs, Ur, and UT values (P<.05). PMMA showed the lowest mean σfs, Ur, and UT values (P<.05), and CAD-CAM/Milled showed σfs values similar to those of 3D-Printed at all thermocycling periods. CAD-CAM/Milled showed the highest Ur values at 10 000 cycles and the highest UT values at all thermocycles. No significant differences were found in the mean change of σfs and Ur of CAD-CAM/Milled among different thermocycling periods. CONCLUSIONS The results suggested that digitally fabricated interim materials had better mechanical properties than conventionally polymerized materials and that milled materials had the highest stability in maintaining their initial capacity to absorb energy.
Collapse
Affiliation(s)
- Simge Taşın
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Cyprus Health and Social Sciences University, Mersin, Turkey.
| | - Artur Ismatullaev
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, University of Kyrenia, Mersin, Turkey
| |
Collapse
|
29
|
Hensel F, Koenig A, Doerfler HM, Fuchs F, Rosentritt M, Hahnel S. CAD/CAM Resin-Based Composites for Use in Long-Term Temporary Fixed Dental Prostheses. Polymers (Basel) 2021; 13:3469. [PMID: 34685228 PMCID: PMC8539791 DOI: 10.3390/polym13203469] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 09/29/2021] [Accepted: 10/04/2021] [Indexed: 12/03/2022] Open
Abstract
The aim of this in vitro study was to analyse the performance of CAD/CAM resin-based composites for the fabrication of long-term temporary fixed dental prostheses (FDP) and to compare it to other commercially available alternative materials regarding its long-term stability. Four CAD/CAM materials [Structur CAD (SC), VITA CAD-Temp (CT), Grandio disc (GD), and Lava Esthetic (LE)] and two direct RBCs [(Structur 3 (S3) and LuxaCrown (LC)] were used to fabricate three-unit FDPs. 10/20 FDPs were subjected to thermal cycling and mechanical loading by chewing simulation and 10/20 FDPs were stored in distilled water. Two FDPs of each material were forwarded to additional image diagnostics prior and after chewing simulation. Fracture loads were measured and data were statistically analysed. SC is suitable for use as a long-term temporary (two years) three-unit FDP. In comparison to CT, SC featured significantly higher breaking forces (SC > 800 N; CT < 600 N) and the surface wear of the antagonists was (significantly) lower and the abrasion of the FDP was similar. The high breaking forces (1100-1327 N) of GD and the small difference compared to LE regarding flexural strength showed that the material might be used for the fabrication of three-unit FDPs. With the exception of S3, all analysed direct or indirect materials are suitable for the fabrication of temporary FDPs.
Collapse
Affiliation(s)
- Franziska Hensel
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany; (F.H.); (H.-M.D.); (F.F.); (S.H.)
| | - Andreas Koenig
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany; (F.H.); (H.-M.D.); (F.F.); (S.H.)
| | - Hans-Martin Doerfler
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany; (F.H.); (H.-M.D.); (F.F.); (S.H.)
- Department of Mechanical and Energy Engineering, University of Applied Sciences, 04277 Leipzig, Germany
| | - Florian Fuchs
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany; (F.H.); (H.-M.D.); (F.F.); (S.H.)
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, Regensburg University Medical Centre, 93053 Regensburg, Germany;
| | - Sebastian Hahnel
- Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany; (F.H.); (H.-M.D.); (F.F.); (S.H.)
| |
Collapse
|
30
|
Oja J, Lassila L, Vallittu PK, Garoushi S. Effect of Accelerated Aging on Some Mechanical Properties and Wear of Different Commercial Dental Resin Composites. MATERIALS 2021; 14:ma14112769. [PMID: 34071137 PMCID: PMC8197073 DOI: 10.3390/ma14112769] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/21/2021] [Accepted: 05/23/2021] [Indexed: 12/28/2022]
Abstract
The aim of current in vitro research was to determine the effect of hydrothermal accelerated aging on the mechanical properties and wear of different commercial dental resin composites (RCs). In addition, the effect of expiration date of the composite prior its use was also evaluated. Five commercially available RCs were studied: Conventional RCs (Filtek Supreme XTE, G-aenial Posterior, Denfil, and >3y expired Supreme XTE), bulk-fill RC (Filtek Bulk Fill), and short fiber-reinforced RC (everX Posterior). Three-point flexural test was used for determination of ultimate flexural strength (n = 8). A vickers indenter was used for testing surface microhardness. A wear test was conducted with 15,000 chewing cycles using a dual-axis chewing simulator. Wear pattern was analyzed by a three-dimensional (3D) noncontact optical profilometer. Degree of C=C bond conversion of monomers was determined by FTIR-spectrometry. The specimens were either dry stored for 48 h (37 °C) or boiled (100 °C) for 16 h before testing. Scanning electron microscopy (SEM) was used to evaluate the microstructure of each material. Data were analyzed using ANOVA (p = 0.05). Hydrothermal aging had no significant effects on the surface wear and microhardness of tested RCs (p > 0.05). While flexural strength significantly decreased after aging (p < 0.05), except for G-aenial Posterior, which showed no differences. The lowest average wear depth was found for Filtek Bulk Fill (29 µm) (p < 0.05), while everX Posterior and Denfil showed the highest wear depth values (40, 39 µm) in both conditions. Passing the expiration date for 40 months did not affect the flexural strength and wear of tested RC. SEM demonstrated a significant number of small pits on Denfil’s surface after aging. It was concluded that the effect of accelerated aging may have caused certain weakening of the RC of some brands, whereas no effect was found with one brand of RC. Thus, the accelerated aging appeared to be more dependent on material and tested material property.
Collapse
Affiliation(s)
- Jonne Oja
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20500 Turku, Finland; (J.O.); (L.L.); (P.K.V.)
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20500 Turku, Finland; (J.O.); (L.L.); (P.K.V.)
| | - Pekka K. Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20500 Turku, Finland; (J.O.); (L.L.); (P.K.V.)
- City of Turku Welfare Division, Oral Health Care, 20101 Turku, Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center—TCBC, Institute of Dentistry, University of Turku, 20500 Turku, Finland; (J.O.); (L.L.); (P.K.V.)
- Correspondence:
| |
Collapse
|
31
|
Dapieve KS, Machry RV, Pereira GKR, Venturini AB, Valcanaia A, Bottino MC, Valandro LF. Alumina particle air-abrasion and aging effects: Fatigue behavior of CAD/CAM resin composite crowns and flexural strength evaluations. J Mech Behav Biomed Mater 2021; 121:104592. [PMID: 34144359 DOI: 10.1016/j.jmbbm.2021.104592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/07/2021] [Accepted: 05/09/2021] [Indexed: 10/21/2022]
Abstract
The aim of this study was to characterize the flexural strength and elastic modulus of CAD/CAM resin composite material and to evaluate the influence of different surface treatments and storage conditions on the fatigue behavior of bonded composite crowns. Bars (flexural strength, n= 30; elastic modulus, n= 5) (1.2 × 4 × 12 mm) were produced for three-point bending test and CAD/CAM milled crowns (n= 5) (thickness= 1 mm) adhesively cemented to an epoxy resin substrate for fatigue tests. Bars and crowns were randomly allocated into two "surface treatments": no surface treatment (CTRL) and air-abrasion with 110 μm Al2O3 particles (AlOx); while the crowns were also subdivided into "aging condition" (baseline - storage for 24 h to 7 days, and aging - storage for 150 days + 25,000 thermal cycles). The three-point bending test was performed according to ISO 6872 and the luted crowns were subjected to step-stress fatigue test (initial load of 200 N; step-size of 50 N; 10,000 cycles per step; 20 Hz). Complementary analysis by Stereomicroscopy and Field Emission Scanning Electron Microscopy (FE-SEM) were performed. The flexural strength and fatigue data were submitted to statistical tests (α= 0.05). The results showed that air-abrasion reduces the flexural strength and the characteristic strength of the resin composite, without modifying its elastic modulus or its structural reliability (Weibull Modulus). Air-abrasion did not influence the fatigue behavior of the cemented crowns. Notwithstanding, a decrease in the survival rate was observed after 445,000 cycles (2,400 N) when subjected to aging at both the CTRL or AlOx conditions. FE-SEM micrographs of the crowns showed that alumina particle air-abrasion treatment can modify the topography of its treated inner surface. Therefore, air-abrasion with alumina powder introduces defects onto the surface of the CAD/CAM resin composite material, decreasing the flexural strength, but without changing its elastic modulus and reliability. Adhesive cementation onto an epoxy resin substrate prevented an influence of the introduced defects on the fatigue performance of the resin composite restoration. Nevertheless, the fatigue behavior may be damaged by aging regimen.
Collapse
Affiliation(s)
- Kiara Serafini Dapieve
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renan Vaz Machry
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andressa Borin Venturini
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - André Valcanaia
- Department of Cariology, Restorative Sciences and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.
| | - Marco Cícero Bottino
- Department of Cariology, Restorative Sciences and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
32
|
Mechanical degradation of contemporary CAD/CAM resin composite materials after water ageing. Dent Mater 2021; 37:1156-1167. [PMID: 33933272 DOI: 10.1016/j.dental.2021.04.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/29/2021] [Accepted: 04/08/2021] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The aim of the present study was to assess the effect of water storage on the quasi-static properties and cyclic fatigue behavior of four contemporary CAD/CAM resin composite materials. METHODS The CAD/CAM resin composites Grandio Blocs, LavaTM Ultimate, CerasmartTM and Brilliant Crios, as well as the direct resin composite Grandio SO, were evaluated. Rectangular plates were cut from the blocks or fabricated using a silicon mold to obtain specimens for fracture toughness (KIc, n = 10), biaxial strength (σ0, n = 30) and cyclic fatigue testing (n = 30). Half of the specimens was stored for 24 h in dry conditions and the other half was aged for 60 days in distilled water at 37 °C. KIc was determined using the Compact-Tension (C(T)) method and σ0 and cyclic fatigue were tested using the Ball-on-Three-Balls assembly. Additional disc-shaped specimens (n = 5) were produced to obtain water sorption curves of the materials. Weibull statistics and two-way ANOVA with Tukey's post-hoc test were used for data assessment. RESULTS The highest water sorption was observed for LavaTM Ultimate (42.6 μg/mm3), whereas Grandio SO displayed the lowest uptake (14 μg/mm3). A statistically significant drop in KIc and σ0 was measured for all materials after water storage, except for the σ0 of CerasmartTM. Water ageing had a dissimilar effect on the cyclic fatigue behavior, increasing the slow crack growth susceptibility of LavaTM Ultimate, but decreasing it for CerasmartTM and Brilliant Crios. SIGNIFICANCE Contemporary CAD/CAM resin composites are susceptible to water driven degradative processes, although differences in filler content and resin matrix constitution play an important role in how it impacts their mechanical properties.
Collapse
|
33
|
Influence of Polymeric Restorative Materials on the Stress Distribution in Posterior Fixed Partial Dentures: 3D Finite Element Analysis. Polymers (Basel) 2021; 13:polym13050758. [PMID: 33670991 PMCID: PMC7957672 DOI: 10.3390/polym13050758] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 01/06/2023] Open
Abstract
Background: This study evaluated the effect of interim restorative materials (acrylic resin (AR), resin composite (RC) or polyetheretherketone (PEEK) for dental computer-aided design/computer-aided manufacturing (CAD/CAM)) on the stress distribution of a posterior three-unit fixed partial denture. Methods: The abutment teeth (first molar and first premolar) were modeled using the BioCAD protocol containing 1.5 mm of axial reduction and converging axial walls. A static structural analysis was performed in the computer-aided engineering software, and the Maximum Principal Stress criterion was used to analyze the prosthesis and the cement layers of both abutment teeth. The materials were considered isotropic, linearly elastic, homogeneous and with bonded contacts. An axial load (600 N) was applied to the occlusal surface of the second premolar. Results: Regardless of the restorative material, the region of the prosthetic connectors showed the highest tensile stress magnitude. The highest stress peak was observed with the use of RC (129 MPa) compared to PEEK and AR. For the cement layers, RC showed the lowest values in the occlusal region (7 MPa) and the highest values for the cervical margin (14 MPa) compared to PEEK (21 and 12 MPa) and AR (21 and 13 MPa). Conclusions: Different interim restorative materials for posterior fixed partial dentures present different biomechanical behavior. The use of resin composite can attenuate the stress magnitude on the cement layer, and the use of acrylic resin can attenuate the stress magnitude on the connector region.
Collapse
|
34
|
Fracture Load of Metal, Zirconia and Polyetheretherketone Posterior CAD-CAM Milled Fixed Partial Denture Frameworks. MATERIALS 2021; 14:ma14040959. [PMID: 33670544 PMCID: PMC7922591 DOI: 10.3390/ma14040959] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 02/10/2021] [Accepted: 02/15/2021] [Indexed: 01/02/2023]
Abstract
The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.
Collapse
|
35
|
Niem T, Heun U, Hübner A, Wöstmann B. Effect of Cartridge Storage Time and Ambient Laboratory Conditions on the Stability of Mechanical Properties of Bis-Acryl Interim Resin Materials. J Prosthodont 2021; 30:795-803. [PMID: 33533059 DOI: 10.1111/jopr.13338] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/19/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To investigate the stability of mechanical properties during the entire shelf life of chemically-activated bis-acryl interim resin materials stored at ambient laboratory conditions. MATERIALS AND METHODS Four bis-acryl interim resin materials with no explicit recommendation for refrigerator storage were selected (Luxatemp Plus, Visalys Temp, Structur 3, Structur Premium). Following cartridge storage at ambient laboratory conditions in 6-month intervals, 30 specimens (2.0 × 2.0 × 25.0 mm3 ) were prepared in each case and stored in distilled water (37.0 ± 1.0 °C) with 3 different water storage times (2 hours, 24 hours, 7 days). Flexural strength, modulus of elasticity, modulus of toughness, and elastic recovery were determined (3-point bend test). Data were subjected to a three-way multivariate analysis of variance (MANOVA) to determine overall significance, followed by a series of separate one-way ANOVAs after data were split, using Tukey and Games-Howell post hoc tests to identify significant differences between groups (α = 0.05). RESULTS While Luxatemp Plus showed no significant decrease for all mechanical properties during the investigated shelf life of 21 months (p > 0.05), Visalys Temp exhibited a continuous decline of the corresponding values (p < 0.05), irrespective of the water storage time. Structur 3 and Structur Premium properties remained almost unchanged during the first 6 months of the examination period. Subsequently, a progressive decrease was observed for flexural strength and modulus of elasticity, while most modulus of toughness and elastic recovery results revealed little alteration. CONCLUSION Depending on the bis-acryl interim resin material, mechanical properties appeared to be susceptible to continuous degradation processes during cartridge storage at ambient conditions, especially towards the end of the material shelf life. For some materials, the chemical stabilization and recommended storage conditions should be revised by the manufacturers to prevent premature aging during shelf life.
Collapse
Affiliation(s)
- Thomas Niem
- Department of Prosthodontics, Justus-Liebig University, Giessen, Germany
| | - Ulrich Heun
- Department of Prosthodontics, Justus-Liebig University, Giessen, Germany
| | - Antje Hübner
- Department of Prosthodontics, Justus-Liebig University, Giessen, Germany
| | - Bernd Wöstmann
- Department of Prosthodontics, Justus-Liebig University, Giessen, Germany
| |
Collapse
|
36
|
Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health 2020; 20:217. [PMID: 32741366 PMCID: PMC7398079 DOI: 10.1186/s12903-020-01202-7] [Citation(s) in RCA: 111] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/20/2020] [Indexed: 02/06/2023] Open
Abstract
Background Advanced computer-aided design and computer-aided manufacturing (CAD-CAM) technology led to the introduction of an increasing number of machinable materials suitable for dental prostheses. One of these materials is polyetheretherketone (PEEK), a high performance polymer recently used in dentistry with favorable physical, mechanical and chemical properties. The purpose of this study was to review the current published literature on the use of PEEK for the fabrication of dental prostheses with CAD-CAM techniques. Methods Electronic database searches were performed using the terms “PEEK”, “CAD-CAM”, “dental”, “dentistry” to identify studies related to the use of PEEK for the fabrication of CAD-CAM prostheses. The search period spanned from January 1990 through February 2020. Both in vivo and in vitro studies in English were eligible. Review articles and the references of the included publications were searched to identify relevant articles. Results A great number of in vitro studies are available in the current literature pointing out the noticeable properties of PEEK. The use of PEEK has been recommended for a wide range of CAD-CAM fabricated fixed and removable dental prostheses. PEEK was additionally recommended for occlusal splints, intra-radicular posts, implant abutments, customized healing abutments and provisional restorations. However, only a few clinical studies were identified. Conclusions PEEK could be considered as a viable alternative for CAD-CAM fixed and removable dental prostheses to well-established dental materials. Due to the scarcity of clinical data, clinical trials are needed to assess the long-term performance of PEEK prostheses.
Collapse
Affiliation(s)
- Ioannis Papathanasiou
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| | - Phophi Kamposiora
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece.
| | - George Papavasiliou
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| | - Marco Ferrari
- Department of Prosthodontics and Dental Materials, School of Dental Medicine, University of Siena, Siena, Italy
| |
Collapse
|