1
|
Dos Santos FV, Siqueira RL, de Morais Ramos L, Yoshioka SA, Branciforti MC, Correa DS. Silk fibroin-derived electrospun materials for biomedical applications: A review. Int J Biol Macromol 2024; 254:127641. [PMID: 37913875 DOI: 10.1016/j.ijbiomac.2023.127641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/14/2023] [Accepted: 10/22/2023] [Indexed: 11/03/2023]
Abstract
Electrospinning is a versatile technique for fabricating polymeric fibers with diameters ranging from micro- to nanoscale, exhibiting multiple morphologies and arrangements. By combining silk fibroin (SF) with synthetic and/or natural polymers, electrospun materials with outstanding biological, chemical, electrical, physical, mechanical, and optical properties can be achieved, fulfilling the evolving biomedical demands. This review highlights the remarkable versatility of SF-derived electrospun materials, specifically focusing on their application in tissue regeneration (including cartilage, cornea, nerves, blood vessels, bones, and skin), disease treatment (such as cancer and diabetes), and the development of controlled drug delivery systems. Additionally, we explore the potential future trends in utilizing these nanofibrous materials for creating intelligent biomaterials, incorporating biosensors and wearable sensors for monitoring human health, and also discuss the bottlenecks for its widespread use. This comprehensive overview illuminates the significant impact and exciting prospects of SF-derived electrospun materials in advancing biomedical research and applications.
Collapse
Affiliation(s)
- Francisco Vieira Dos Santos
- Nanotechnology National Laboratory for Agriculture, Embrapa Instrumentação, 13560-970 São Carlos, SP, Brazil; Materials Engineering Department, São Carlos School of Engineering, University of São Paulo, 13563-120 São Carlos, SP, Brazil
| | - Renato Luiz Siqueira
- Materials Engineering Department, Federal University of São Carlos, 13565-905 São Carlos, SP, Brazil
| | - Lucas de Morais Ramos
- São Carlos Institute of Physics, University of São Paulo, 13560-970 São Carlos, SP, Brazil
| | - Sérgio Akinobu Yoshioka
- Laboratory of Biochemistry and Biomaterials, São Carlos Institute of Chemistry, University of São Paulo, 13560-970 São Carlos, SP, Brazil
| | - Márcia Cristina Branciforti
- Materials Engineering Department, São Carlos School of Engineering, University of São Paulo, 13563-120 São Carlos, SP, Brazil
| | - Daniel Souza Correa
- Nanotechnology National Laboratory for Agriculture, Embrapa Instrumentação, 13560-970 São Carlos, SP, Brazil; Materials Engineering Department, São Carlos School of Engineering, University of São Paulo, 13563-120 São Carlos, SP, Brazil.
| |
Collapse
|
2
|
Kim YE, Bae YJ, Jang MJ, Um IC. Effect of Sericin Content on the Structural Characteristics and Properties of New Silk Nonwoven Fabrics. Biomolecules 2023; 13:1186. [PMID: 37627251 PMCID: PMC10452508 DOI: 10.3390/biom13081186] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/25/2023] [Accepted: 07/27/2023] [Indexed: 08/27/2023] Open
Abstract
Recently, natural silk nonwoven fabrics have attracted attention in biomedical and cosmetic applications because of their excellent biocompatibility, mechanical properties, and easy preparation. Herein, silk nonwoven fabrics were prepared by carding silk filaments to improve their productivity, and the effect of sericin content on the structure and properties of silk nonwoven fabrics was investigated. Owing to the binding effect of sericin in silk, a natural silk nonwoven fabric was successfully prepared through carding, wetting, and hot press treatments. Sericin content affected the structural characteristics and properties of the silk nonwoven fabrics. As the sericin content increased, the silk nonwoven fabrics became more compact with reduced porosity and thickness. Further, with increasing sericin content, the crystallinity and elongation of the silk nonwoven fabrics decreased while the moisture regain and the maximum stress increased. The thermal stability of most silk nonwoven fabrics was not affected by the sericin content. However, silk nonwoven fabrics without sericin had a lower thermal decomposition temperature than other nonwoven fabrics. Regardless of the sericin content, all silk nonwoven fabrics exhibited optimal cell viability and are promising candidates for cosmetic and biomedical applications.
Collapse
Affiliation(s)
- Ye Eun Kim
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Republic of Korea (Y.J.B.)
| | - Yu Jeong Bae
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Republic of Korea (Y.J.B.)
| | - Mi Jin Jang
- Preclinical Research Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu 41061, Republic of Korea
| | - In Chul Um
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Republic of Korea (Y.J.B.)
| |
Collapse
|
3
|
Choi YY, Jang MJ, Park BD, Um IC. Fabrication, Structure, and Properties of Nonwoven Silk Fabrics Prepared with Different Cocoon Layers. Int J Mol Sci 2023; 24:11485. [PMID: 37511244 PMCID: PMC10380708 DOI: 10.3390/ijms241411485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/07/2023] [Accepted: 07/12/2023] [Indexed: 07/30/2023] Open
Abstract
In this study, five different nonwoven silk fabrics were fabricated with silk fibers from different cocoon layers, and the effect of the cocoon layer on the structural characteristics and properties of the nonwoven silk fabric was examined. The diameter of the silk fiber and thickness of the nonwoven silk fabric decreased from the outer to the inner cocoon layer. More amino acids with higher hydrophilicity (serine, aspartic acid, and glutamic acid) and lower hydrophilicity (glycine and alanine) were observed in the outer layers. From the outer to the inner layer, the overall crystallinity and contact angle of the nonwoven silk fabric increased, whereas its yellowness index, moisture retention, and mechanical properties decreased. Regardless of the cocoon layer at which the fiber was sourced, the thermal stability of fibroin and sericin and good cell viability remained unchanged. The results of this study indicate that the properties of nonwoven silk fabric can be controlled by choosing silk fibers from the appropriate cocoon layers. Moreover, the findings in this study will increase the applicability of nonwoven silk fabric in the biomedical and cosmetic fields, which require specific properties for industrialization.
Collapse
Affiliation(s)
- Yun Yeong Choi
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Republic of Korea
| | - Mi Jin Jang
- Preclinical Research Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu 41061, Republic of Korea
| | - Byung-Dae Park
- Department of Wood and Paper Science, Kyungpook National University, Daegu 41566, Republic of Korea
| | - In Chul Um
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Republic of Korea
| |
Collapse
|
4
|
Hu P, Armato U, Freddi G, Chiarini A, Dal Prà I. Human Keratinocytes and Fibroblasts Co-Cultured on Silk Fibroin Scaffolds Exosomally Overrelease Angiogenic and Growth Factors. Cells 2023; 12:1827. [PMID: 37508492 PMCID: PMC10378127 DOI: 10.3390/cells12141827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 06/30/2023] [Accepted: 07/10/2023] [Indexed: 07/30/2023] Open
Abstract
Objectives: The optimal healing of skin wounds, deep burns, and chronic ulcers is an important clinical problem. Attempts to solve it have been driving the search for skin equivalents based on synthetic or natural polymers. Methods: Consistent with this endeavor, we used regenerated silk fibroin (SF) from Bombyx mori to produce a novel compound scaffold by welding a 3D carded/hydroentangled SF-microfiber-based nonwoven layer (C/H-3D-SFnw; to support dermis engineering) to an electrospun 2D SF nanofiber layer (ESFN; a basal lamina surrogate). Next, we assessed-via scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, differential scanning calorimetry, mono- and co-cultures of HaCaT keratinocytes and adult human dermal fibroblasts (HDFs), dsDNA assays, exosome isolation, double-antibody arrays, and angiogenesis assays-whether the C/H-3D-SFnws/ESFNs would allow the reconstitution of a functional human skin analog in vitro. Results: Physical analyses proved that the C/H-3D-SFnws/ESFNs met the requirements for human soft-tissue-like implants. dsDNA assays revealed that co-cultures of HaCaTs (on the 2D ESFN surface) and HDFs (inside the 3D C/H-3D-SFnws) grew more intensely than did the respective monocultures. Double-antibody arrays showed that the CD9+/CD81+ exosomes isolated from the 14-day pooled growth media of HDF and/or HaCaT mono- or co-cultures conveyed 35 distinct angiogenic/growth factors (AGFs). However, versus monocultures' exosomes, HaCaT/HDF co-cultures' exosomes (i) transported larger amounts of 15 AGFs, i.e., PIGF, ANGPT-1, bFGF, Tie-2, Angiogenin, VEGF-A, VEGF-D, TIMP-1/-2, GRO-α/-β/-γ, IL-1β, IL-6, IL-8, MMP-9, and MCP-1, and (ii) significantly more strongly stimulated human dermal microvascular endothelial cells to migrate and assemble tubes/nodes in vitro. Conclusions: Our results showed that both cell-cell and cell-SF interactions boosted the exosomal release of AGFs from HaCaTs/HDFs co-cultured on C/H-3D-SFnws/ESFNs. Hence, such exosomes are an asset for prospective clinical applications as they advance cell growth and neoangiogenesis and consequently graft take and skin healing. Moreover, this new integument analog could be instrumental in preclinical and translational studies on human skin pathophysiology and regeneration.
Collapse
Affiliation(s)
- Peng Hu
- Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, 37134 Verona, Italy
| | - Ubaldo Armato
- Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, 37134 Verona, Italy
| | | | - Anna Chiarini
- Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, 37134 Verona, Italy
| | - Ilaria Dal Prà
- Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, 37134 Verona, Italy
| |
Collapse
|
5
|
Yoon T, Shin H, Park W, Kim Y, Na S. Biochemical mechanism involved in the enhancement of the Young's modulus of silk by the SpiCE protein. J Mech Behav Biomed Mater 2023; 143:105878. [PMID: 37207525 DOI: 10.1016/j.jmbbm.2023.105878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/16/2023] [Accepted: 04/29/2023] [Indexed: 05/21/2023]
Abstract
Silk fibers are known for their superior mechanical properties, with the strongest possessing over seven times the toughness of kevlar. Recently, low molecular weight non-spidroin protein, spider-silk constituting element (SpiCE), has been reported to enhance the mechanical properties of silk; however, its specific action mechanism has not yet been elucidated. Here, we explored the mechanism by which SpiCE strengthened the mechanical properties of major ampullate spidroin 2 (MaSp2) silk through hydrogen bonds and salt bridges of the silk structure via all-atom molecular dynamics simulations. Tensile pulling simulation on silk fiber with SpiCE protein revealed that the SpiCE protein enhanced the Young's modulus by up to 40% more than that of the wild type. Bond characteristic analysis revealed that SpiCE and MaSp2 formed more hydrogen bonds and salt bridges than the MaSp2 wild-type model. Sequence analysis of MaSp2 silk fiber and SpiCE protein revealed that SpiCE protein contained more amino acids that could act as hydrogen bond acceptors/donors and salt bridge partners. Our results provide insights into the mechanism by which non-spidroin proteins strengthen the properties of silk fibers and lay the groundwork for the development of material selection criteria for the design of de novo artificial silk fibers.
Collapse
Affiliation(s)
- Taeyoung Yoon
- Department of Mechanical Engineering, Korea University, 02841, Seoul, Republic of Korea
| | - Hongchul Shin
- Department of Mechanical Engineering, Korea University, 02841, Seoul, Republic of Korea
| | - Wooboum Park
- Department of Mechanical Engineering, Korea University, 02841, Seoul, Republic of Korea
| | - Yoonjung Kim
- Department of Mechanical Engineering, Korea University, 02841, Seoul, Republic of Korea
| | - Sungsoo Na
- Department of Mechanical Engineering, Korea University, 02841, Seoul, Republic of Korea.
| |
Collapse
|
6
|
Phutane P, Telange D, Agrawal S, Gunde M, Kotkar K, Pethe A. Biofunctionalization and Applications of Polymeric Nanofibers in Tissue Engineering and Regenerative Medicine. Polymers (Basel) 2023; 15:polym15051202. [PMID: 36904443 PMCID: PMC10007057 DOI: 10.3390/polym15051202] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 02/07/2023] [Accepted: 02/09/2023] [Indexed: 03/06/2023] Open
Abstract
The limited ability of most human tissues to regenerate has necessitated the interventions namely autograft and allograft, both of which carry the limitations of its own. An alternative to such interventions could be the capability to regenerate the tissue in vivo.Regeneration of tissue using the innate capacity of the cells to regenerate is studied under the discipline of tissue engineering and regenerative medicine (TERM). Besides the cells and growth-controlling bioactives, scaffolds play the central role in TERM which is analogous to the role performed by extracellular matrix (ECM) in the vivo. Mimicking the structure of ECM at the nanoscale is one of the critical attributes demonstrated by nanofibers. This unique feature and its customizable structure to befit different types of tissues make nanofibers a competent candidate for tissue engineering. This review discusses broad range of natural and synthetic biodegradable polymers employed to construct nanofibers as well as biofunctionalization of polymers to improve cellular interaction and tissue integration. Amongst the diverse ways to fabricate nanofibers, electrospinning has been discussed in detail along with advances in this technique. Review also presents a discourse on application of nanofibers for a range of tissues, namely neural, vascular, cartilage, bone, dermal and cardiac.
Collapse
Affiliation(s)
- Prasanna Phutane
- Department of Pharmaceutics, Datta Meghe Institute of Higher Education and Research, Datta Meghe College of Pharmacy, Wardha 442004, MH, India
- Correspondence:
| | - Darshan Telange
- Department of Pharmaceutics, Datta Meghe Institute of Higher Education and Research, Datta Meghe College of Pharmacy, Wardha 442004, MH, India
| | - Surendra Agrawal
- Department of Pharmaceutical Chemistry, Datta Meghe Institute of Higher Education and Research, Datta Meghe College of Pharmacy, Wardha 442004, MH, India
| | - Mahendra Gunde
- Department of Pharmacognosy, Datta Meghe Institute of Higher Education and Research, Datta Meghe College of Pharmacy, Wardha 442004, MH, India
| | - Kunal Kotkar
- Department of Pharmaceutical Quality Assurance, R.C. Patel Institute of Pharmaceutical Education and Research, Shirpur 425405, MH, India
| | - Anil Pethe
- Department of Pharmaceutics, Datta Meghe Institute of Higher Education and Research, Datta Meghe College of Pharmacy, Wardha 442004, MH, India
| |
Collapse
|
7
|
Hu MH, Yang KC, Chen CW, Chu PH, Chang YL, Sun YH, Lin FH, Yang SH. Multilayer Electrospun-Aligned Fibroin/Gelatin Implant for Annulus Fibrosus Repair: An In Vitro and In Vivo Evaluation. Biomedicines 2022; 10:biomedicines10092107. [PMID: 36140208 PMCID: PMC9495938 DOI: 10.3390/biomedicines10092107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 08/19/2022] [Accepted: 08/23/2022] [Indexed: 11/16/2022] Open
Abstract
Annulus fibrosus (AF) damage is proven to prompt intervertebral disc (IVD) degeneration, and unrepaired AF lesions after surgical discectomy may boost herniation of the nucleus pulposus (NP) which may lead to further compression of neural structures. Moreover, vascular and neural ingrowth may occur within the defect which is known as a possible reason for discogenic pain. Due to a limited healing capacity, an effective strategy to repair and close the AF defect is necessary. In this study, using electrospinning technology, two nature polymers, silk fibroin and gelatin, were linked to imitate the unique lamellae structure of native AF. Our findings revealed that a multilayer electrospun-aligned fibroin/gelatin scaffold with mechanical and morphological properties mimicking those of native AF lamellae have been developed. The average diameter of the nanofiber is 162.9 ± 38.8 nm. The young’s modulus is around 6.70 MPa with an ultimate tensile strength of around 1.81 MP along preferred orientation. The in vitro test confirmed its biocompatibility and ability to maintain cell viability and colonization. Using a porcine model, we demonstrated that the multilayer-aligned scaffold offered a crucial microenvironment to induce collagen fibrous tissue production within native AF defect. In the implant-repaired AF, H&E staining showed homogeneous fibroblast-like cell infiltration at the repaired defect with very little vascular ingrowth, which was confirmed by magnetic resonance imaging findings. Picrosirius red staining and immunohistochemical staining against type I collagen revealed positively stained fibrous tissue in an aligned pattern within the implant-integrated site. Relative to the intact control group, the disc height index of the serial X-ray decreased significantly in both the injury control and implant group at 4 weeks and 8 weeks (p < 0.05) which indicated this scaffold may not reverse the degenerative process. However, the results of the discography showed that the effectiveness of annulus repair of the implant group is much superior to that of the untreated group. The scaffold, composed with nature fibroin/gelatin polymers, could potentially enhance AF healing that could prevent IVD recurrent herniation, as well as neural and neovascular ingrowth after discectomy surgeries.
Collapse
Affiliation(s)
- Ming-Hsiao Hu
- Department of Orthopedics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100225, Taiwan
| | - Kai-Chiang Yang
- Department of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Chih-Wei Chen
- Department of Orthopedics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100225, Taiwan
- Department of Biomedical Engineering, National Taiwan University, Taipei 106216, Taiwan
| | - Po-Han Chu
- Department of Biomedical Engineering, National Taiwan University, Taipei 106216, Taiwan
| | - Yun-Liang Chang
- Department of Orthopedics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100225, Taiwan
| | - Yuan-Hui Sun
- Department of Orthopedics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100225, Taiwan
| | - Feng-Huei Lin
- Department of Biomedical Engineering, National Taiwan University, Taipei 106216, Taiwan
| | - Shu-Hua Yang
- Department of Orthopedics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100225, Taiwan
- Correspondence: ; Tel.: +886-2-2312-3456 (ext. 63981)
| |
Collapse
|
8
|
Silk Vascular Grafts with Optimized Mechanical Properties for the Repair and Regeneration of Small Caliber Blood Vessels. MATERIALS 2022; 15:ma15103735. [PMID: 35629761 PMCID: PMC9147556 DOI: 10.3390/ma15103735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 05/13/2022] [Accepted: 05/18/2022] [Indexed: 01/27/2023]
Abstract
As the incidence of cardiovascular diseases has been growing in recent years, the need for small-diameter vascular grafts is increasing. Considering the limited success of synthetic grafts, vascular tissue engineering/repair/regeneration aim to find novel solutions. Silk fibroin (SF) has been widely investigated for the development of vascular grafts, due to its good biocompatibility, tailorable biodegradability, excellent mechanical properties, and minimal inflammatory reactions. In this study, a new generation of three-layered SF vascular scaffolds has been produced and optimized. Four designs of the SILKGraft vascular prosthesis have been developed with the aim of improving kink resistance and mechanical strength, without compromising the compliance with native vessels and the proven biocompatibility. A more compact arrangement of the textile layer allowed for the increase in the mechanical properties along the longitudinal and circumferential directions and the improvement of the compliance value, which approached that reported for the saphenous and umbilical veins. The higher braid density slightly affected the grafts’ morphology, increasing surface roughness, but the novel design mimicked the corrugation approach used for synthetic grafts, causing significant improvements in kink resistance.
Collapse
|
9
|
Biagiotti M, Bassani GA, Chiarini A, Vincoli VT, Dal Prà I, Cosentino C, Alessandrino A, Taddei P, Freddi G. Electrospun Silk Fibroin Scaffolds for Tissue Regeneration: Chemical, Structural, and Toxicological Implications of the Formic Acid-Silk Fibroin Interaction. Front Bioeng Biotechnol 2022; 10:833157. [PMID: 35155396 PMCID: PMC8829063 DOI: 10.3389/fbioe.2022.833157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 01/10/2022] [Indexed: 01/11/2023] Open
Abstract
The dissolution of Bombyx mori silk fibroin (SF) films in formic acid (FA) for the preparation of electrospinning dopes is widely exploited to produce electrospun SF scaffolds. The SILKBridge® nerve conduit is an example of medical device having in its wall structure an electrospun component produced from an FA spinning dope. Though highly volatile, residual FA remains trapped into the bulk of the SF nanofibers. The purpose of this work is to investigate the type and strength of the interaction between FA and SF in electrospun mats, to quantify its amount and to evaluate its possible toxicological impact on human health. The presence of residual FA in SF mats was detected by FTIR and Raman spectroscopy (new carbonyl peak at about 1,725 cm−1) and by solid state NMR, which revealed a new carbonyl signal at about 164.3 ppm, attributed to FA by isotopic 13C substitution. Changes occurred also in the spectral ranges of hydroxylated amino acids (Ser and Thr), demonstrating that FA interacted with SF by forming formyl esters. The total amount of FA was determined by HS-GC/MS analysis and accounted for 247 ± 20 μmol/g. The greatest part was present as formyl ester, a small part (about 3%) as free FA. Approximately 17% of the 1,500 μmol/g of hydroxy amino acids (Ser and Thr) theoretically available were involved in the formation of formyl esters. Treatment with alkali (Na2CO3) succeeded to remove the greatest part of FA, but not all. Alkali-treated electrospun SF mats underwent morphological, physical, and mechanical changes. The average diameter of the fibers increased from about 440 nm to about 480 nm, the mat shrunk, became stiffer (the modulus increased from about 5.5 MPa to about 7 MPa), and lost elasticity (the strain decreased from about 1 mm/mm to about 0.8 mm/mm). Biocompatibility studies with human adult dermal fibroblasts did not show significant difference in cell proliferation (313 ± 18 and 309 ± 23 cells/mm2 for untreated and alkali-treated SF mat, respectively) and metabolic activity. An in-depth evaluation of the possible toxicological impact of residual FA was made using the SILKBridge® nerve conduit as case study, following the provisions of the ISO 10993-1 standard. The Potential Patient Daily Intake, calculated from the total amount of FA determined by HS-GC/MS, was 2.4 mg/day and the Tolerable Exposure level was set to 35.4 mg/day. This allowed to obtain a value of the Margin of Safety of 15, indicating that the amount of FA left on SF mats after electrospinning does not raise concerns for human health.
Collapse
Affiliation(s)
| | | | - Anna Chiarini
- Department of Surgery, Dentistry, Pediatrics and Gynecology, Human Histology and Embryology Unit, Medical School, University of Verona, Verona, Italy
| | | | - Ilaria Dal Prà
- Department of Surgery, Dentistry, Pediatrics and Gynecology, Human Histology and Embryology Unit, Medical School, University of Verona, Verona, Italy
| | | | | | - Paola Taddei
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Giuliano Freddi
- Silk Biomaterials S.r.l, Lomazzo, Italy
- *Correspondence: Giuliano Freddi,
| |
Collapse
|
10
|
Gupta P, Mandal BB. Silk biomaterials for vascular tissue engineering applications. Acta Biomater 2021; 134:79-106. [PMID: 34384912 DOI: 10.1016/j.actbio.2021.08.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 08/04/2021] [Accepted: 08/05/2021] [Indexed: 02/07/2023]
Abstract
Vascular tissue engineering is a rapidly growing field of regenerative medicine, which strives to find innovative solutions for vascular reconstruction. Considering the limited success of synthetic grafts, research impetus in the field is now shifted towards finding biologically active vascular substitutes bestowing in situ growth potential. In this regard, silk biomaterials have shown remarkable potential owing to their favorable inherent biological and mechanical properties. This review provides a comprehensive overview of the progressive development of silk-based small diameter (<6 mm) tissue-engineered vascular grafts (TEVGs), emphasizing their pre-clinical implications. Herein, we first discuss the molecular structure of various mulberry and non-mulberry silkworm silk and identify their favorable properties at the onset of vascular regeneration. The emergence of various state-of-the-art fabrication methodologies for the advancement of silk TEVGs is rationally appraised in terms of their in vivo performance considering the following parameters: ease of handling, long-term patency, resistance to acute thrombosis, stenosis and aneurysm formation, immune reaction, neo-tissue formation, and overall remodeling. Finally, we provide an update on the pre-clinical status of silk-based TEVGs, followed by current challenges and future prospects. STATEMENT OF SIGNIFICANCE: Limited availability of healthy autologous blood vessels to replace their diseased counterpart is concerning and demands other artificial substitutes. Currently available synthetic grafts are not suitable for small diameter blood vessels owing to frequent blockage. Tissue-engineered biological grafts tend to integrate well with the native tissue via remodeling and have lately witnessed remarkable success. Silk fibroin is a natural biomaterial, which has long been used as medical sutures. This review aims to identify several favorable properties of silk enabling vascular regeneration. Furthermore, various methodologies to fabricate tubular grafts are discussed and highlight their performance in animal models. An overview of our understanding to rationally improve the biological activity fostering the clinical success of silk-based grafts is finally discussed.
Collapse
|
11
|
Rickel AP, Deng X, Engebretson D, Hong Z. Electrospun nanofiber scaffold for vascular tissue engineering. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112373. [PMID: 34579892 DOI: 10.1016/j.msec.2021.112373] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 07/28/2021] [Accepted: 08/10/2021] [Indexed: 12/16/2022]
Abstract
Due to the prevalence of cardiovascular diseases, there is a large need for small diameter vascular grafts that cannot be fulfilled using autologous vessels. Although medium to large diameter synthetic vessels are in use, no suitable small diameter vascular graft has been developed due to the unique dynamic environment that exists in small vessels. To achieve long term patency, a successful tissue engineered vascular graft would need to closely match the mechanical properties of native tissue, be non-thrombotic and non-immunogenic, and elicit the proper healing response and undergo remodeling to incorporate into the native vasculature. Electrospinning presents a promising approach to the development of a suitable tissue engineered vascular graft. This review provides a comprehensive overview of the different polymers, techniques, and functionalization approaches that have been used to develop an electrospun tissue engineered vascular graft.
Collapse
Affiliation(s)
- Alex P Rickel
- The Department of Biomedical Engineering, The University of South Dakota, Sioux Falls, SD 57107, United States of America
| | - Xiajun Deng
- The Department of Biomedical Engineering, The University of South Dakota, Sioux Falls, SD 57107, United States of America
| | - Daniel Engebretson
- The Department of Biomedical Engineering, The University of South Dakota, Sioux Falls, SD 57107, United States of America
| | - Zhongkui Hong
- The Department of Biomedical Engineering, The University of South Dakota, Sioux Falls, SD 57107, United States of America.
| |
Collapse
|
12
|
Tanaka T, Ibe Y, Jono T, Tanaka R, Naito A, Asakura T. Characterization of a Water-Dispersed Biodegradable Polyurethane-Silk Composite Sponge Using 13C Solid-State Nuclear Magnetic Resonance as Coating Material for Silk Vascular Grafts with Small Diameters. Molecules 2021; 26:4649. [PMID: 34361802 PMCID: PMC8347230 DOI: 10.3390/molecules26154649] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/12/2021] [Accepted: 07/27/2021] [Indexed: 11/30/2022] Open
Abstract
Recently, Bombyx mori silk fibroin (SF) has been shown to be a suitable material for vascular prostheses for small arteries. In this study, we developed a softer SF graft by coating water-dispersed biodegradable polyurethane (PU) based on polycaprolactone and an SF composite sponge on the knitted SF vascular graft. Three kinds of 13C solid-state nuclear magnetic resonance (NMR), namely carbon-13 (13C) cross-polarization/magic angle spinning (MAS), 13C dipolar decoupled MAS, and 13C refocused insensitive nuclei enhanced by polarization transfer (r-INEPT) NMR, were used to characterize the PU-SF coating sponge. Especially the 13C r-INEPT NMR spectrum of water-dispersed biodegradable PU showed that both main components of the non-crystalline domain of PU and amorphous domain of SF were highly mobile in the hydrated state. Then, the small-diameter SF artificial vascular grafts coated with this sponge were evaluated through implantation experiments with rats. The implanted PU-SF-coated SF grafts showed a high patency rate. It was confirmed that the inside of the SF grafts was covered with vascular endothelial cells 4 weeks after implantation. These results showed that the water-dispersed biodegradable PU-SF-coated SF graft created in this study could be a strong candidate for small-diameter artificial vascular graft.
Collapse
Affiliation(s)
- Takashi Tanaka
- Department of Veterinary Science, Tokyo University of Agriculture and Technology, Tokyo 183-8509, Japan; (T.T.); (R.T.)
| | - Yusuke Ibe
- Polyurethane Research Laboratory, Tosoh Corporation, Mie 510-8540, Japan; (Y.I.); (T.J.)
| | - Takaki Jono
- Polyurethane Research Laboratory, Tosoh Corporation, Mie 510-8540, Japan; (Y.I.); (T.J.)
| | - Ryo Tanaka
- Department of Veterinary Science, Tokyo University of Agriculture and Technology, Tokyo 183-8509, Japan; (T.T.); (R.T.)
| | - Akira Naito
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan;
| | - Tetsuo Asakura
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan;
| |
Collapse
|
13
|
Atehortua C, Montoya Y, García A, Bustamante J. Hemolytic, Biocompatible, and Functional Effect of Cellularized Polycaprolactone-Hydrolyzed Collagen Electrospun Membranes for Possible Application as Vascular Implants. J Biomed Nanotechnol 2021; 17:1184-1198. [PMID: 34167631 DOI: 10.1166/jbn.2021.3087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In search of bioactive vascular prostheses that exhibit greater biocompatibility through the combination of natural and synthetic polymers, tissue engineering from a biomimetic perspective has proposed the development of three-dimensional structures as therapeutic strategies in the field of cardiovascular medicine. Techniques such as electrospinning allow obtaining of scaffolds that emulate the microarchitecture of the extracellular matrix of native vessels; thus, this study aimed to evaluate the biological influence of microarchitecture on polycaprolactone (PCL) and hydrolyzed collagen (H-Col) electrospun scaffolds, which have a homogeneous (microscale) or heterogeneous (micro-nanoscale) fibrillar structure. The hemolytic, biocompatible, and functional effect of the scaffolds in interaction with an in vitro fibroblast model was determined, in view of its potential use for vascular implants. Scaffolds were characterized by scanning electron microscopy and atomic force microscopy, Fourier transform infrared spectroscopy, wettability, static permeability, tensile test, and degradation. In addition, direct and indirect 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assays were used to identify the cell viability of fibroblasts, fluorescence assays were performed to establish morphological changes of the cell nuclei, and the hemolytic effect of the scaffolds was calculated. Results showed that ethanol-treated biocompositescaffolds exhibited mass losses lower than 6.65% and slow wettability and absorption, resulting from an increase in secondary structures that contribute to the crystalline phase of H-Col. The scaffolds demonstrated stable degradation in saline during the incubation period because of the availability of soluble structures in aqueous media, and the inclusion of H-Col increased the elastic properties of the scaffold. As regards hemocompatibility, the scaffolds had hemolysis levels lower than 1%; moreover, in terms of biocompatible characteristics, scaffolds exhibited good adhesion, proliferation, and cell viability and insignificant changes in the circularity of the cell nuclei. However, scaffolds with homogeneous fibers showed cell agglomerates after 48 h of interaction. By contrast, permeability decreased as the incubation period progressed, because of the cellularization of the three-dimensional structure. In conclusion, multiscale scaffolds could exhibit a suitable behavior as a bioactive small-diameter vascular implant.
Collapse
Affiliation(s)
- Camilo Atehortua
- Grupo de Dinámica Cardiovascular, Centro de Bioingeniería, Universidad Pontificia Bolivariana, Medellín 050031, Colombia
| | - Yuliet Montoya
- Grupo de Dinámica Cardiovascular, Centro de Bioingeniería, Universidad Pontificia Bolivariana, Medellín 050031, Colombia
| | - Alejandra García
- Laboratorio de Síntesis y Modificación de Nanoestructuras y Materiales Bidimensionales, Centro de Investigación en Materiales Avanzados S.C. Parque PIIT Alianza Norte 202, Apodaca 66600, México
| | - John Bustamante
- Grupo de Dinámica Cardiovascular, Centro de Bioingeniería, Universidad Pontificia Bolivariana, Medellín 050031, Colombia
| |
Collapse
|
14
|
Frazão LP, Fernandes AM, Oliveira C, Martins A, Silva TH, Vieira de Castro J, Nogueira-Silva C, Neves NM. New Vascular Graft Using the Decellularized Human Chorion Membrane. ACS Biomater Sci Eng 2021; 7:3423-3433. [PMID: 34097827 DOI: 10.1021/acsbiomaterials.1c00293] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The increase of both arterial occlusive diseases and coronary heart diseases leads to a higher demand for small-diameter vascular grafts (<6 mm). The gold standard for small-diameter vessel replacement is the use of autologous veins. Nevertheless, up to 30% of these patients need to use vascular grafts. Although synthetic polymers have been successfully used for the replacement of large-diameter vascular grafts (>6 mm), they are associated with thrombosis, intimal hyperplasia, calcification, and chronic inflammation when used as small-diameter vascular grafts. Therefore, natural materials have been studied for this application. In this study, a decellularized human chorion membrane (dHCM) vascular graft with a 3-4 mm diameter was created. Herein, the biocompatibility of dHCM with endothelial cells was demonstrated in vitro and ex ovo. Blood biocompatibility of dHCM was also shown by studying plasma protein adsorption, platelet adhesion and activation, and its hemolytic potential. Furthermore, dHCM antibacterial properties against Staphylococcus aureus were also studied. In summary, the dHCM reticular layer side presented all the needed characteristics to be used in the inner side of a vascular graft. Additionally, the mechanical properties of the dHCM tubular construct were studied, being similar to the ones of the saphenous vein, the gold standard for autologous small-diameter vessel replacement.
Collapse
Affiliation(s)
- Laura P Frazão
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Ana M Fernandes
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Catarina Oliveira
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Albino Martins
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Tiago H Silva
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Joana Vieira de Castro
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Cristina Nogueira-Silva
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal.,Life and Health Sciences Research Institute, School of Medicine, University of Minho, 4710-057 Braga, Portugal.,Department of Obstetrics and Gynecology, Hospital de Braga, 4710-243 Braga, Portugal
| | - Nuno M Neves
- I3B's-Research Institute on Biomaterials, Biodegradables and Biomimetics of University of Minho: 3Bs Research Group, 4805-017 Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| |
Collapse
|
15
|
Lepedda AJ, Nieddu G, Formato M, Baker MB, Fernández-Pérez J, Moroni L. Glycosaminoglycans: From Vascular Physiology to Tissue Engineering Applications. Front Chem 2021; 9:680836. [PMID: 34084767 PMCID: PMC8167061 DOI: 10.3389/fchem.2021.680836] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 05/03/2021] [Indexed: 12/27/2022] Open
Abstract
Cardiovascular diseases represent the number one cause of death globally, with atherosclerosis a major contributor. Despite the clinical need for functional arterial substitutes, success has been limited to arterial replacements of large-caliber vessels (diameter > 6 mm), leaving the bulk of demand unmet. In this respect, one of the most challenging goals in tissue engineering is to design a "bioactive" resorbable scaffold, analogous to the natural extracellular matrix (ECM), able to guide the process of vascular tissue regeneration. Besides adequate mechanical properties to sustain the hemodynamic flow forces, scaffold's properties should include biocompatibility, controlled biodegradability with non-toxic products, low inflammatory/thrombotic potential, porosity, and a specific combination of molecular signals allowing vascular cells to attach, proliferate and synthesize their own ECM. Different fabrication methods, such as phase separation, self-assembly and electrospinning are currently used to obtain nanofibrous scaffolds with a well-organized architecture and mechanical properties suitable for vascular tissue regeneration. However, several studies have shown that naked scaffolds, although fabricated with biocompatible polymers, represent a poor substrate to be populated by vascular cells. In this respect, surface functionalization with bioactive natural molecules, such as collagen, elastin, fibrinogen, silk fibroin, alginate, chitosan, dextran, glycosaminoglycans (GAGs), and growth factors has proven to be effective. GAGs are complex anionic unbranched heteropolysaccharides that represent major structural and functional ECM components of connective tissues. GAGs are very heterogeneous in terms of type of repeating disaccharide unit, relative molecular mass, charge density, degree and pattern of sulfation, degree of epimerization and physicochemical properties. These molecules participate in a number of vascular events such as the regulation of vascular permeability, lipid metabolism, hemostasis, and thrombosis, but also interact with vascular cells, growth factors, and cytokines to modulate cell adhesion, migration, and proliferation. The primary goal of this review is to perform a critical analysis of the last twenty-years of literature in which GAGs have been used as molecular cues, able to guide the processes leading to correct endothelialization and neo-artery formation, as well as to provide readers with an overall picture of their potential as functional molecules for small-diameter vascular regeneration.
Collapse
Affiliation(s)
| | - Gabriele Nieddu
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| | - Marilena Formato
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy
| | - Matthew Brandon Baker
- Complex Tissue Regeneration Department, MERLN Institute for Technology Inspired Regenerative Medicine, Maastricht, Netherlands
| | - Julia Fernández-Pérez
- Complex Tissue Regeneration Department, MERLN Institute for Technology Inspired Regenerative Medicine, Maastricht, Netherlands
| | - Lorenzo Moroni
- Complex Tissue Regeneration Department, MERLN Institute for Technology Inspired Regenerative Medicine, Maastricht, Netherlands
| |
Collapse
|
16
|
Bae YS, Um IC. Effects of Fabrication Conditions on Structure and Properties of Mechanically Prepared Natural Silk Web and Non-Woven Fabrics. Polymers (Basel) 2021; 13:polym13101578. [PMID: 34069044 PMCID: PMC8156477 DOI: 10.3390/polym13101578] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/10/2021] [Accepted: 05/12/2021] [Indexed: 12/25/2022] Open
Abstract
In this study, natural silk web and natural silk non-woven fabric were prepared mechanically using the binding character of the sericin in silk. The effect of process variables on the preparation, structure, and properties of the silk web and the non-woven fabric was examined. The reeling velocity affected the morphology and mechanical properties of the web but had almost no influence on the crystalline structure of the silk. From the viewpoint of reel-ability and the mechanical properties (work of rupture) of silk web, a reeling velocity of 39.2 m/min represented the optimal processing velocity. The porosity and swelling ratio of the silk web decreased slightly with increasing reeling velocity. Furthermore, the reeling bath temperature had a significant effect on the reel-ability of silk filaments from a silkworm cocoon. Bath temperatures ≥50 °C yielded good reel-ability (>900 m reeling length). The porosity, swelling ratio in water, and mechanical properties of the silk web and silk non-woven fabric changed only slightly with the reeling bath temperature but changed significantly with the hot press treatment. The hot-pressed silk web (i.e., silk non-woven fabric) exhibited higher tensile strength as well as lower elongation at break, porosity, and swelling ratio than the silk web.
Collapse
Affiliation(s)
- Yeon-Su Bae
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Korea;
| | - In-Chul Um
- Department of Biofibers and Biomaterials Science, Kyungpook National University, Daegu 41566, Korea;
- Institute of Agricultural Science and Technology, Kyungpook National University, Daegu 41566, Korea
- Correspondence: ; Tel.: +82-53-950-7757; Fax: +82-53-950-6744
| |
Collapse
|
17
|
Maintaining Inducibility of Dermal Follicle Cells on Silk Fibroin/Sodium Alginate Scaffold for Enhanced Hair Follicle Regeneration. BIOLOGY 2021; 10:biology10040269. [PMID: 33810528 PMCID: PMC8066588 DOI: 10.3390/biology10040269] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 03/23/2021] [Accepted: 03/23/2021] [Indexed: 12/17/2022]
Abstract
The extracellular matrix (ECM) is important for maintaining cell phenotype and promoting cell proliferation and differentiation. In order to better solve the problem of skin appendage regeneration, a combination of mechanical/enzymatic digestion methods was used to self-extract dermal papilla cells (DPCs), which were seeded on silk fibroin/sodium alginate scaffolds as seed cells to evaluate the possibility of skin regeneration/regeneration of accessory organs. Scanning electron microscopy (SEM) graphs showed that the interconnected pores inside the scaffold had a pore diameter in the range of 153-311 μm and a porosity of 41-82%. Immunofluorescence (IF) staining and cell morphological staining proved that the extracted cells were DPCs. The results of a Cell Counting Kit-8 (CCK-8) and Calcein-AM/PI live-dead cell staining showed that the DPCs grew well in the composite scaffold extract. Normal cell morphology and characteristics of aggregation growth were maintained during the 3-day culture, which showed that the silk fibroin/sodium alginate (SF/SA) composite scaffold had good cell-compatibility. Hematoxylin-eosin (H&E) staining of tissue sections further proved that the cells adhered closely and aggregated to the pore wall of the scaffold, and retained the ability to induce differentiation of hair follicles. All these results indicate that, compared with a pure scaffold, the composite scaffold promotes the adhesion and growth of DPCs. We transplanted the SF/SA scaffolds into the back wounds of SD rats, and evaluated the damage model constructed in vivo. The results showed that the scaffold inoculated with DPCs could accelerate the repair of the skin and promote the regeneration of the hair follicle structure.
Collapse
|
18
|
Khademolqorani S, Tavanai H, Chronakis IS, Boisen A, Ajalloueian F. The determinant role of fabrication technique in final characteristics of scaffolds for tissue engineering applications: A focus on silk fibroin-based scaffolds. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 122:111867. [PMID: 33641889 DOI: 10.1016/j.msec.2021.111867] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 01/04/2021] [Accepted: 01/06/2021] [Indexed: 02/05/2023]
Abstract
3D scaffolds are in the center of attention for tissue engineering applications. Whilst many studies have focused on the biological properties of scaffolds, less attention has been paid to meeting the biomechanics of the target tissues. In this work, we show how using the same original biomaterial, but different fabrication techniques can lead to a broad range of structural, mechanical, and biological characteristics. Starting with silk fibroin filament as our base biomaterial, we employed electrospinning, film casting, and weft knitting as different scaffold fabrication techniques. Among these three, the weft knit scaffold showed outstanding cell-scaffold interaction including full 3D cell attachment, complete cell coverage around individual filaments, and in-depth cell infiltration. Post-fabrication degumming of silk filament yarns resulted in more bulky and less open pores for the silk fibroin knit scaffold. The decreased pore size after degumming of knit scaffold alleviated the need to in-advance pore filling (a requisite for increasing cell adhesion in a typical knit scaffold having big pores). From a mechanical viewpoint, the weft knit scaffold shows the highest mechanical strength alongside with far better extensibility. Interestingly, the silk filament weft knit scaffold (in the course direction) was 100 and 1000 times more compliant than silk fibroin film and electrospun web, respectively. The observed effect of material type and fabrication technique highlights the suitability of silk fibroin weft-knit scaffolds for the regeneration of load-bearing soft tissues such as urine bladder.
Collapse
Affiliation(s)
- Sanaz Khademolqorani
- Department of Textile Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
| | - Hossein Tavanai
- Department of Textile Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran; Research Institute for Nanotechnology and Advanced Materials, Isfahan University of Technology, Isfahan 84156-83111, Iran
| | - Ioannis S Chronakis
- Nano-Bioscience Research Group, DTU-Food, Technical University of Denmark, Kemitorvet, B202, 2800 Kgs. Lyngby, Denmark
| | - Anja Boisen
- Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark; The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark
| | - Fatemeh Ajalloueian
- Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark; The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Ørsted Plads, 2800 Kgs. Lyngby, Denmark.
| |
Collapse
|
19
|
Sta. Agueda JRH, Chen Q, Maalihan RD, Ren J, da Silva ÍGM, Dugos NP, Caldona EB, Advincula RC. 3D printing of biomedically relevant polymer materials and biocompatibility. MRS COMMUNICATIONS 2021; 11:197-212. [PMID: 33936866 PMCID: PMC8075026 DOI: 10.1557/s43579-021-00038-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 04/08/2021] [Indexed: 05/06/2023]
Abstract
ABSTRACT Research on polymer materials for additive manufacturing technology in biomedical applications is as promising as it is numerous, but biocompatibility of printable materials still remains a big challenge. Changes occurring during the 3D-printing processes itself may have adverse effects on the compatibility of the completed print. This prospective will put emphasis on the different additives and processes that can have a direct impact on biocompatibility during and after 3D printing of polymer materials.
Collapse
Affiliation(s)
- Joseph Rey H. Sta. Agueda
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
- Department of Manufacturing Engineering and Management, De La Salle University, 1004 Manila, Philippines
- Department of Chemical Engineering, De La Salle University, 1004 Manila, Philippines
| | - Qiyi Chen
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
- Center for Nanophase Materials and Sciences, Oak Ridge National Laboratory, Oak Ridge, TN 37830 USA
| | - Reymark D. Maalihan
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
- Department of Chemical and Food Engineering and Material Testing and Calibration Center, Batangas State University, 4200 Batangas City, Philippines
| | - Jingbo Ren
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Ítalo G. M. da Silva
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
- Escola de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ 21941-909 Brazil
| | - Nathaniel P. Dugos
- Department of Chemical Engineering, De La Salle University, 1004 Manila, Philippines
| | - Eugene B. Caldona
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
- Department of Chemical and Biomolecular Engineering and Joint Institute for Advanced Materials, University of Tennessee, Knoxville, TN 37996 USA
| | - Rigoberto C. Advincula
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
- Department of Chemical and Biomolecular Engineering and Joint Institute for Advanced Materials, University of Tennessee, Knoxville, TN 37996 USA
- Center for Nanophase Materials and Sciences, Oak Ridge National Laboratory, Oak Ridge, TN 37830 USA
| |
Collapse
|
20
|
Farasatkia A, Kharaziha M, Ashrafizadeh F, Salehi S. Transparent silk/gelatin methacrylate (GelMA) fibrillar film for corneal regeneration. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 120:111744. [DOI: 10.1016/j.msec.2020.111744] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/20/2020] [Accepted: 11/18/2020] [Indexed: 12/13/2022]
|
21
|
Zheng-Yang He, -Chen Q, Wu YT, Pan ZJ. Biopolymer Composite Nanofibers Electrospun from Regenerated Silk Fibroin and PHBV: Fabrication Method, Morphology and Thermal Stability. POLYMER SCIENCE SERIES A 2020. [DOI: 10.1134/s0965545x2006005x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
22
|
Obiweluozor FO, Emechebe GA, Kim DW, Cho HJ, Park CH, Kim CS, Jeong IS. Considerations in the Development of Small-Diameter Vascular Graft as an Alternative for Bypass and Reconstructive Surgeries: A Review. Cardiovasc Eng Technol 2020; 11:495-521. [PMID: 32812139 DOI: 10.1007/s13239-020-00482-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Accepted: 08/11/2020] [Indexed: 02/06/2023]
Abstract
BACKGROUND Current design strategies for small diameter vascular grafts (< 6 mm internal diameter; ID) are focused on mimicking native vascular tissue because the commercially available grafts still fail at small diameters, notably due to development of intimal hyperplasia and thrombosis. To overcome these challenges, various design approaches, material selection, and surface modification strategies have been employed to improve the patency of small-diameter grafts. REVIEW The purpose of this review is to outline various considerations in the development of small-diameter vascular grafts, including material choice, surface modifications to enhance biocompatibility/endothelialization, and mechanical properties of the graft, that are currently being implanted. Additionally, we have taken into account the general vascular physiology, tissue engineering approaches, and collective achievements of the authors in this area. We reviewed both commercially available synthetic grafts (e-PTFE and PET), elastic polymers such as polyurethane and biodegradable and bioresorbable materials. We included naturally occurring materials by focusing on their potential application in the development of future vascular alternatives. CONCLUSION Until now, there are few comprehensive reviews regarding considerations in the design of small-diameter vascular grafts in the literature. Here-in, we have discussed in-depth the various strategies employed to generate engineered vascular graft due to their high demand for vascular surgeries. While some TEVG design strategies have shown greater potential in contrast to autologous or synthetic ePTFE conduits, many are still hindered by high production cost which prevents their widespread adoption. Nonetheless, as tissue engineers continue to develop on their strategies and procedures for improved TEVGs, soon, a reliable engineered graft will be available in the market. Hence, we anticipate a viable TEVG with resorbable property, fabricated via electrospinning approach to hold a greater potential that can overcome the challenges observed in both autologous and allogenic grafts. This is because they can be mechanically tuned, incorporated/surface-functionalized with bioactive molecules and mass-manufactured in a reproducible manner. It is also found that most of the success in engineered vascular graft approaching commercialization is for large vessels rather than small-diameter grafts used as cardiovascular bypass grafts. Consequently, the field of vascular engineering is still available for future innovators that can take up the challenge to create a functional arterial substitute.
Collapse
Affiliation(s)
- Francis O Obiweluozor
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea.
| | - Gladys A Emechebe
- Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
| | - Do-Wan Kim
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea
| | - Hwa-Jin Cho
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea
| | - Chan Hee Park
- Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
- Department of Mechanical Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
| | - Cheol Sang Kim
- Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
- Department of Mechanical Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea
| | - In Seok Jeong
- Department of Cardiac and Thoracic Surgery, Chonnam National University Hospital and Medical School, 42 Jebong-Ro Dong-gu, Gwangju, 501-757, Republic of Korea.
| |
Collapse
|
23
|
Zhao J, Feng Y. Surface Engineering of Cardiovascular Devices for Improved Hemocompatibility and Rapid Endothelialization. Adv Healthc Mater 2020; 9:e2000920. [PMID: 32833323 DOI: 10.1002/adhm.202000920] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 07/18/2020] [Indexed: 12/13/2022]
Abstract
Cardiovascular devices have been widely applied in the clinical treatment of cardiovascular diseases. However, poor hemocompatibility and slow endothelialization on their surface still exist. Numerous surface engineering strategies have mainly sought to modify the device surface through physical, chemical, and biological approaches to improve surface hemocompatibility and endothelialization. The alteration of physical characteristics and pattern topographies brings some hopeful outcomes and plays a notable role in this respect. The chemical and biological approaches can provide potential signs of success in the endothelialization of vascular device surfaces. They usually involve therapeutic drugs, specific peptides, adhesive proteins, antibodies, growth factors and nitric oxide (NO) donors. The gene engineering can enhance the proliferation, growth, and migration of vascular cells, thus boosting the endothelialization. In this review, the surface engineering strategies are highlighted and summarized to improve hemocompatibility and rapid endothelialization on the cardiovascular devices. The potential outlook is also briefly discussed to help guide endothelialization strategies and inspire further innovations. It is hoped that this review can assist with the surface engineering of cardiovascular devices and promote future advancements in this emerging research field.
Collapse
Affiliation(s)
- Jing Zhao
- School of Chemical Engineering and Technology Tianjin University Yaguan Road 135 Tianjin 300350 P. R. China
| | - Yakai Feng
- School of Chemical Engineering and Technology Tianjin University Yaguan Road 135 Tianjin 300350 P. R. China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) Yaguan Road 135 Tianjin 300350 P. R. China
- Key Laboratory of Systems Bioengineering (Ministry of Education) Tianjin University Tianjin 300072 P. R. China
| |
Collapse
|
24
|
Li H, Song G, Tian W, Ding M, Sun X, Xu J, Dong F, Wang A, Ning P, Yin Y, Wang J. Motility and function of smooth muscle cells in a silk small-caliber tubular scaffold after replacement of rabbit common carotid artery. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 114:110977. [DOI: 10.1016/j.msec.2020.110977] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 04/06/2020] [Accepted: 04/15/2020] [Indexed: 12/17/2022]
|
25
|
Awad NK, Wong CS, Zhou H, Niu H, Wang H, Morsi YS, Lin T. Effect of elasticity on electrospun styrene-butadiene-styrene fibrous membrane cell culture behaviors. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2020; 31:2114-2127. [PMID: 32664796 DOI: 10.1080/09205063.2020.1795054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
In this study, elastic styrene-butadiene-styrene (SBS), non-elastic SBS and their blends at different ratios were electrospun into fibrous membranes and their cell biocompatibility was evaluated. The as-spun fibers showed an average fiber diameter of 2 µm, and the fibrous membranes had pore size of 8 ± 0.01 µm. The blending ratios of the elastic with non-elastic SBSs showed little effect on fibrous structure, but affected the mechanical properties. All SBS membrane showed no cytotoxicity on endothelial cells (ECs). ECs attached and proliferated on all the SBS fibrous membrane scaffolds regardless of their elasticity. ECs maintained their polygonal shape on the scaffolds and they tended to orient along the fiber length. The SBS fibrous samples with elastic:non-elastic SBS weight ratios of 1:1 and 2:3 showed better cell viability than that of elastic and non-elastic SBS.
Collapse
Affiliation(s)
- Nasser K Awad
- Biomechanical and Tissue Engineering Labs, Swinburne University of Technology, Hawthorn, Australia.,Institute for Frontier Materials, Deakin University, Geelong, Australia.,Electrochemistry and Corrosion Laboratory, National Research Centre, Cairo, Egypt
| | - Cynthia S Wong
- Institute for Frontier Materials, Deakin University, Geelong, Australia
| | - Hua Zhou
- Institute for Frontier Materials, Deakin University, Geelong, Australia
| | - Haitao Niu
- Institute for Frontier Materials, Deakin University, Geelong, Australia
| | - Hongxia Wang
- Institute for Frontier Materials, Deakin University, Geelong, Australia
| | - Yosry S Morsi
- Biomechanical and Tissue Engineering Labs, Swinburne University of Technology, Hawthorn, Australia
| | - Tong Lin
- Institute for Frontier Materials, Deakin University, Geelong, Australia
| |
Collapse
|
26
|
Akbari S, Mohebbi-Kalhori D, Samimi A. Effect of corrugated structure on the collapsing of the small-diameter vascular scaffolds. J Biomater Appl 2020; 34:1355-1367. [DOI: 10.1177/0885328220910021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Saeed Akbari
- Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Islamic Republic of Iran
| | - Davod Mohebbi-Kalhori
- Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Islamic Republic of Iran
| | - Abdolreza Samimi
- Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Islamic Republic of Iran
| |
Collapse
|
27
|
Wang D, Xu Y, Li Q, Turng LS. Artificial small-diameter blood vessels: materials, fabrication, surface modification, mechanical properties, and bioactive functionalities. J Mater Chem B 2020; 8:1801-1822. [PMID: 32048689 PMCID: PMC7155776 DOI: 10.1039/c9tb01849b] [Citation(s) in RCA: 63] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Cardiovascular diseases, especially ones involving narrowed or blocked blood vessels with diameters smaller than 6 millimeters, are the leading cause of death globally. Vascular grafts have been used in bypass surgery to replace damaged native blood vessels for treating severe cardio- and peripheral vascular diseases. However, autologous replacement grafts are not often available due to prior harvesting or the patient's health. Furthermore, autologous harvesting causes secondary injury to the patient at the harvest site. Therefore, artificial blood vessels have been widely investigated in the last several decades. In this review, the progress and potential outlook of small-diameter blood vessels (SDBVs) engineered in vitro are highlighted and summarized, including material selection and development, fabrication techniques, surface modification, mechanical properties, and bioactive functionalities. Several kinds of natural and synthetic polymers for artificial SDBVs are presented here. Commonly used fabrication techniques, such as extrusion and expansion, electrospinning, thermally induced phase separation (TIPS), braiding, 3D printing, hydrogel tubing, gas foaming, and a combination of these methods, are analyzed and compared. Different surface modification methods, such as physical immobilization, surface adsorption, plasma treatment, and chemical immobilization, are investigated and are compared here as well. Mechanical requirements of SDBVs are also reviewed for long-term service. In vitro biological functions of artificial blood vessels, including oxygen consumption, nitric oxide (NO) production, shear stress response, leukocyte adhesion, and anticoagulation, are also discussed. Finally, we draw conclusions regarding current challenges and attempts to identify future directions for the optimal combination of materials, fabrication methods, surface modifications, and biofunctionalities. We hope that this review can assist with the design, fabrication, and application of SDBVs engineered in vitro and promote future advancements in this emerging research field.
Collapse
Affiliation(s)
- Dongfang Wang
- Department of Mechanical Engineering, University of Wisconsin, Madison, WI, USA. and Wisconsin Institute for Discovery, University of Wisconsin, Madison, WI, USA and School of Mechanics and Engineering Science, Zhengzhou University, Zhengzhou 450001, P. R. China and National Center for International Research of Micro-Nano Molding Technology, Zhengzhou University, Zhengzhou 450001, P. R. China
| | - Yiyang Xu
- Department of Mechanical Engineering, University of Wisconsin, Madison, WI, USA. and Wisconsin Institute for Discovery, University of Wisconsin, Madison, WI, USA
| | - Qian Li
- School of Mechanics and Engineering Science, Zhengzhou University, Zhengzhou 450001, P. R. China and National Center for International Research of Micro-Nano Molding Technology, Zhengzhou University, Zhengzhou 450001, P. R. China
| | - Lih-Sheng Turng
- Department of Mechanical Engineering, University of Wisconsin, Madison, WI, USA. and Wisconsin Institute for Discovery, University of Wisconsin, Madison, WI, USA
| |
Collapse
|
28
|
Behr J, Irvine SA, Thwin C, Shah AH, Bae MK, Zussman E, Venkatraman S. Matching Static and Dynamic Compliance of Small‐Diameter Arteries, with Poly(lactide‐
co
‐caprolactone) Copolymers: In Vitro and In Vivo Studies. Macromol Biosci 2020; 20:e1900234. [DOI: 10.1002/mabi.201900234] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 11/06/2019] [Indexed: 12/19/2022]
Affiliation(s)
- Jean‐Marc Behr
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Scott Alexander Irvine
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Chaw‐Su Thwin
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Ankur Harish Shah
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Min‐Chul Kraun Bae
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| | - Eyal Zussman
- Nano Engineering groupFaculty of Mechanical EngineeringTechnion–Israel Institute of Technology Haifa 32000 Israel
| | - Subbu Venkatraman
- School of Materials Science and EngineeringNanyang Technological University 50 Nanyang Avenue Singapore 639798 Singapore
| |
Collapse
|
29
|
Jo SB, Erdenebileg U, Dashnyam K, Jin GZ, Cha JR, El-Fiqi A, Knowles JC, Patel KD, Lee HH, Lee JH, Kim HW. Nano-graphene oxide/polyurethane nanofibers: mechanically flexible and myogenic stimulating matrix for skeletal tissue engineering. J Tissue Eng 2020; 11:2041731419900424. [PMID: 32076499 PMCID: PMC7001895 DOI: 10.1177/2041731419900424] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Accepted: 12/18/2019] [Indexed: 12/16/2022] Open
Abstract
For skeletal muscle engineering, scaffolds that can stimulate myogenic differentiation of cells while possessing suitable mechanical properties (e.g. flexibility) are required. In particular, the elastic property of scaffolds is of importance which helps to resist and support the dynamic conditions of muscle tissue environment. Here, we developed highly flexible nanocomposite nanofibrous scaffolds made of polycarbonate diol and isosorbide-based polyurethane and hydrophilic nano-graphene oxide added at concentrations up to 8%. The nano-graphene oxide incorporation increased the hydrophilicity, elasticity, and stress relaxation capacity of the polyurethane-derived nanofibrous scaffolds. When cultured with C2C12 cells, the polyurethane-nano-graphene oxide nanofibers enhanced the initial adhesion and spreading of cells and further the proliferation. Furthermore, the polyurethane-nano-graphene oxide scaffolds significantly up-regulated the myogenic mRNA levels and myosin heavy chain expression. Of note, the cells on the flexible polyurethane-nano-graphene oxide nanofibrous scaffolds could be mechanically stretched to experience dynamic tensional force. Under the dynamic force condition, the cells expressed significantly higher myogenic differentiation markers at both gene and protein levels and exhibited more aligned myotubular formation. The currently developed polyurethane-nano-graphene oxide nanofibrous scaffolds, due to their nanofibrous morphology and high mechanical flexibility, along with the stimulating capacity for myogenic differentiation, are considered to be a potential matrix for future skeletal muscle engineering.
Collapse
Affiliation(s)
- Seung Bin Jo
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
| | - Uyanga Erdenebileg
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
| | - Khandmaa Dashnyam
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
| | - Guang-Zhen Jin
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
| | - Jae-Ryung Cha
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
| | - Ahmed El-Fiqi
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
| | - Jonathan C. Knowles
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
- Division of Biomaterials and Tissue
Engineering, Eastman Dental Institute, University College London, London, UK
- The Discoveries Centre for Regenerative
and Precision Medicine, Eastman Dental Institute, University College London, London,
UK
| | - Kapil Dev Patel
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
| | - Hae-Hyoung Lee
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
- Department of Biomaterials Science,
College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Jung-Hwan Lee
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
- Department of Biomaterials Science,
College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Hae-Won Kim
- Institute of Tissue Regeneration
Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and
BK21 PLUS NBM Global Research Center for Regenerative Medicine, Dankook University,
Cheonan, Republic of Korea
- UCL Eastman-Korea Dental Medicine
Innovation Centre, Dankook University, Cheonan, Republic of Korea
- Department of Biomaterials Science,
College of Dentistry, Dankook University, Cheonan, Republic of Korea
| |
Collapse
|
30
|
Alessandrino A, Chiarini A, Biagiotti M, Dal Prà I, Bassani GA, Vincoli V, Settembrini P, Pierimarchi P, Freddi G, Armato U. Three-Layered Silk Fibroin Tubular Scaffold for the Repair and Regeneration of Small Caliber Blood Vessels: From Design to in vivo Pilot Tests. Front Bioeng Biotechnol 2019; 7:356. [PMID: 31850325 PMCID: PMC6895545 DOI: 10.3389/fbioe.2019.00356] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Accepted: 11/08/2019] [Indexed: 01/12/2023] Open
Abstract
Silk fibroin (SF) is an eligible biomaterial for the development of small caliber vascular grafts for substitution, repair, and regeneration of blood vessels. This study presents the properties of a newly designed multi-layered SF tubular scaffold for vascular grafting (SilkGraf). The wall architecture consists of two electrospun layers (inner and outer) and an intermediate textile layer. The latter was designed to confer high mechanical performance and resistance on the device, while electrospun layers allow enhancing its biomimicry properties and host's tissues integration. In vitro cell interaction studies performed with adult Human Coronary Artery Endothelial Cells (HCAECs), Human Aortic Smooth Muscle Cells (HASMCs), and Human Aortic Adventitial Fibroblasts (HAAFs) demonstrated that the electrospun layers favor cell adhesion, survival, and growth. Once cultured in vitro on the SF scaffold the three cell types showed an active metabolism (consumption of glucose and glutamine, release of lactate), and proliferation for up to 20 days. HAAF cells grown on SF showed a significantly lower synthesis of type I procollagen than on polystyrene, meaning a lower fibrotic effect of the SF substrate. The cytokine and chemokine expression patterns were investigated to evaluate the cells' proliferative and pro-inflammatory attitude. Interestingly, no significant amounts of truly pro-inflammatory cytokines were secreted by any of the three cell types which exhibited a clearly proliferative profile. Good hemocompatibility was observed by complement activation, hemolysis, and hematology assays. Finally, the results of an in vivo preliminary pilot trial on minipig and sheep to assess the functional behavior of implanted SF-based vascular graft identified the sheep as the more apt animal model for next medium-to-long term preclinical trials.
Collapse
Affiliation(s)
| | - Anna Chiarini
- Human Histology & Embryology Section, Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, Verona, Italy
| | | | - Ilaria Dal Prà
- Human Histology & Embryology Section, Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, Verona, Italy
| | | | | | | | | | | | - Ubaldo Armato
- Human Histology & Embryology Section, Department of Surgery, Dentistry, Pediatrics & Gynecology, University of Verona Medical School, Verona, Italy
| |
Collapse
|
31
|
Chen L, Al-Shawk A, Rea C, Mazeh H, Wu X, Chen W, Li Y, Song W, Markel DC, Ren W. Preparation of electrospun nanofibers with desired microstructures using a programmed three-dimensional (3D) nanofiber collector. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 106:110188. [PMID: 31753331 DOI: 10.1016/j.msec.2019.110188] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 08/28/2019] [Accepted: 09/09/2019] [Indexed: 02/06/2023]
Abstract
The traditional electrospinning process produces dense two-dimensional (2D) nanofiber (NF) sheets that limit cell infiltration and proliferation. Our previous study demonstrated that 3D NF sheets could be formed on an NF collector surface mounted with multiple movable needles through the corona discharge. In this study, we developed a programmed electrospun 3D NF collector. It can precisely control the moving speed of NF collector during electrospinning; thereby fabricating 3D NFs with desired microstructures (pore size, pore volume, and interconnectivity). Four types of polycaprolactone (PCL) 3D NF matrices with different microstructures can be obtained concurrently on the NF collector surface, which are set by different forward moving speed of the NF collector device: NF-zero (no move, as control), NF-low (0.085 mm/min), NF-mid (0.158 mm/min) and NF-high (0.232 mm/min). A linear increase of the NF sheet thickness (from 0.21 mm to 0.91 mm) was recorded with accelerating collector movement. Quantitative analysis using scanning electron microscopy (SEM), micro-computed tomography (μ-CT), and confocal laser scanning microscopy (CLSM) showed a monotonic increase of pore size and porosity with the increase of collector moving speeds. The collector movement also impacted the crystallinity and mechanical properties of the NFs. When prepared at high collector speed, the NFs showed improved proliferation and differentiation (p < .05) of pre-osteoblastic MC3T3 cells compared to the NFs from the static collector. A programmed NF collector device allows for the reproducible, precise and continuous fabrication of 3D NFs with tailorable geometry and microstructures. This simple, controllable, one-step process could promote the clinical translation of electrospun NFs in tissue engineering and regenerative medicine.
Collapse
Affiliation(s)
- Liang Chen
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA
| | - Ameer Al-Shawk
- Department of Mechanic Engineering, Wayne State University, Detroit, MI 48201, USA
| | - Christopher Rea
- Department of Engineering Technology, Wayne State University, Detroit, MI 48201, USA
| | - Hanan Mazeh
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA
| | - Xin Wu
- Department of Mechanic Engineering, Wayne State University, Detroit, MI 48201, USA
| | - Wen Chen
- Department of Engineering Technology, Wayne State University, Detroit, MI 48201, USA
| | - Yawen Li
- Department of Biomedical Engineering, Lawrence Technological University, Southfield, MI 48075, USA
| | - Wei Song
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA
| | - David C Markel
- Department of Orthopedics, Providence Hospital and Medical Center, Southfield, MI 48075, USA
| | - Weiping Ren
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; Department of Orthopedics, Providence Hospital and Medical Center, Southfield, MI 48075, USA; John D. Dingle VA Medical Center, Detroit, MI 48202, USA.
| |
Collapse
|
32
|
Alessandrino A, Fregnan F, Biagiotti M, Muratori L, Bassani GA, Ronchi G, Vincoli V, Pierimarchi P, Geuna S, Freddi G. SilkBridge™: a novel biomimetic and biocompatible silk-based nerve conduit. Biomater Sci 2019; 7:4112-4130. [PMID: 31359013 DOI: 10.1039/c9bm00783k] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Silk fibroin (Bombyx mori) was used to manufacture a nerve conduit (SilkBridge™) characterized by a novel 3D architecture. The wall of the conduit consists of two electrospun layers (inner and outer) and one textile layer (middle), perfectly integrated at the structural and functional level. The manufacturing technology conferred high compression strength on the device, thus meeting clinical requirements for physiological and pathological compressive stresses. In vitro cell interaction studies were performed through direct contact assays with SilkBridge™ using the glial RT4-D6P2T cells, a schwannoma cell line, and a mouse motor neuron NSC-34 cell line. The results revealed that the material is capable of sustaining cell proliferation, that the glial RT4-D6P2T cells increased their density and organized themselves in a glial-like morphology, and that NSC-34 motor neurons exhibited a greater neuritic length with respect to the control substrate. In vivo pilot assays were performed on adult female Wistar rats. A 10 mm long gap in the median nerve was repaired with 12 mm SilkBridge™. At two weeks post-operation several cell types colonized the lumen. Cells and blood vessels were also visible between the different layers of the conduit wall. Moreover, the presence of regenerated myelinated fibers with a thin myelin sheath at the proximal level was observed. Taken together, all these results demonstrated that SilkBridge™ has an optimized balance of biomechanical and biological properties, being able to sustain a perfect cellular colonization of the conduit and the progressive growth of the regenerating nerve fibers.
Collapse
Affiliation(s)
| | - F Fregnan
- Department of Clinical and Biological Sciences, University of Torino, 10124 Torino, Italy and Neuroscience Institute Cavalieri Ottolenghi, University of Torino, 10124 Torino, Italy
| | - M Biagiotti
- Silk Biomaterials Srl, 22074 Lomazzo (Co), Italy.
| | - L Muratori
- Department of Clinical and Biological Sciences, University of Torino, 10124 Torino, Italy and Neuroscience Institute Cavalieri Ottolenghi, University of Torino, 10124 Torino, Italy
| | - G A Bassani
- Silk Biomaterials Srl, 22074 Lomazzo (Co), Italy.
| | - G Ronchi
- Department of Clinical and Biological Sciences, University of Torino, 10124 Torino, Italy and Neuroscience Institute Cavalieri Ottolenghi, University of Torino, 10124 Torino, Italy
| | - V Vincoli
- Silk Biomaterials Srl, 22074 Lomazzo (Co), Italy.
| | - P Pierimarchi
- Institute of Translational Pharmacology, National Research Council, 00083 Rome, Italy
| | - S Geuna
- Department of Clinical and Biological Sciences, University of Torino, 10124 Torino, Italy and Neuroscience Institute Cavalieri Ottolenghi, University of Torino, 10124 Torino, Italy
| | - G Freddi
- Silk Biomaterials Srl, 22074 Lomazzo (Co), Italy.
| |
Collapse
|
33
|
Asakura T, Tanaka T, Tanaka R. Advanced Silk Fibroin Biomaterials and Application to Small-Diameter Silk Vascular Grafts. ACS Biomater Sci Eng 2019; 5:5561-5577. [PMID: 33405687 DOI: 10.1021/acsbiomaterials.8b01482] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
As the incidences of cardiovascular diseases have been on the rise in recent years, the need for small-diameter artificial vascular grafts is increasing globally. Although synthetic polymers such as expanded polytetrafluoroethylene or poly(ethylene terephthalate) have been successfully used for artificial vascular grafts ≥6 mm in diameter, they fail at smaller diameters (<6 mm) due to thrombus formation and intimal hyperplasia. Thus, development of vascular grafts for small diameter vessel replacement that are <6 mm in diameter remains a major clinical challenge. Silk fibroin (SF) from Bombyx mori silkworm is well-known as an excellent textile and also has been used as suture material in surgery for more than 2000 years. Many attempts to develop small-diameter SF vascular grafts with <6 mm in diameter have been reported. Here, research and development in small-diameter vascular grafts with SF are reviewed as follows: (1) the heterogeneous structure of SF fiber (Silk II), including the packing arrangements and type II β-turn structure of SF (Silk I*) before spinning; (2) SF modified by transgenic silkworm, which is more suitable for vascular grafts; (3) preparation of small-diameter SF vascular grafts; (4) characterization of SF in the hydrated state, including dynamics of water molecules by nuclear magnetic resonance; and (5) evaluation of the SF grafts by in vivo implantation experiment. According to the findings, SF is a promising material for small-diameter vascular graft development.
Collapse
Affiliation(s)
- Tetsuo Asakura
- Department of Biotechnology, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| | - Takashi Tanaka
- Department of Biotechnology, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| | - Ryo Tanaka
- Department of Biotechnology, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| |
Collapse
|
34
|
Li X, Zhao H. Mechanical and degradation properties of small-diameter vascular grafts in an in vitro biomimetic environment. J Biomater Appl 2019; 33:1017-1034. [DOI: 10.1177/0885328218820751] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Small-diameter vascular grafts may fail after implantation due to various reasons from mechanical and biological aspects. In order to evaluate the mechanical durability of small-diameter vascular grafts after implantation, an artificial vascular biomimetic environment that can simulate body temperature, the liquid environment outside the vessel, and continuous blood flow and pulsatile pressure was constructed. This device can be used as a “pre-test” prior to animal experiments to explore the changes of mechanical and degradation properties in the long-term in vivo environment. At the same time, braided tube-reinforced silk fibroin/poly (l-lactic acid-co-ε-caprolactone) small-diameter vascular grafts were fabricated and tested under the biomimetic environment. Mechanical changes, including tensile properties, suture retention strength, compliance, and degradation behavior of the braided tube-reinforced poly (l-lactic acid-co-ε-caprolactone)/silk fibroin small-diameter vascular grafts were explored over various periods of time in the biomimetic environment. The results shown that under a period of testing in the in vitro biomimetic environment, the comprehensive mechanical properties (including tensile properties, suture retention strength, estimated-bursting pressure, and compliance) of small-diameter vascular grafts exhibited varying degrees of changes but that there was no obvious degradation behavior in the short term.
Collapse
Affiliation(s)
- Xiangshun Li
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, China
| | - Huijing Zhao
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, China
| |
Collapse
|
35
|
Holland C, Numata K, Rnjak‐Kovacina J, Seib FP. The Biomedical Use of Silk: Past, Present, Future. Adv Healthc Mater 2019; 8:e1800465. [PMID: 30238637 DOI: 10.1002/adhm.201800465] [Citation(s) in RCA: 367] [Impact Index Per Article: 73.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 08/04/2018] [Indexed: 11/07/2022]
Abstract
Humans have long appreciated silk for its lustrous appeal and remarkable physical properties, yet as the mysteries of silk are unraveled, it becomes clear that this outstanding biopolymer is more than a high-tech fiber. This progress report provides a critical but detailed insight into the biomedical use of silk. This journey begins with a historical perspective of silk and its uses, including the long-standing desire to reverse engineer silk. Selected silk structure-function relationships are then examined to appreciate past and current silk challenges. From this, biocompatibility and biodegradation are reviewed with a specific focus of silk performance in humans. The current clinical uses of silk (e.g., sutures, surgical meshes, and fabrics) are discussed, as well as clinical trials (e.g., wound healing, tissue engineering) and emerging biomedical applications of silk across selected formats, such as silk solution, films, scaffolds, electrospun materials, hydrogels, and particles. The journey finishes with a look at the roadmap of next-generation recombinant silks, especially the development pipeline of this new industry for clinical use.
Collapse
Affiliation(s)
- Chris Holland
- Department of Materials Science and Engineering The University of Sheffield Sir Robert Hadfield Building, Mappin Street Sheffield South Yorkshire S1 3JD UK
| | - Keiji Numata
- Biomacromolecules Research Team RIKEN Center for Sustainable Resource Science 2‐1 Hirosawa Wako Saitama 351‐0198 Japan
| | - Jelena Rnjak‐Kovacina
- Graduate School of Biomedical Engineering The University of New South Wales Sydney NSW 2052 Australia
| | - F. Philipp Seib
- Leibniz Institute of Polymer Research Dresden Max Bergmann Center of Biomaterials Dresden Dresden 01069 Germany
- Strathclyde Institute of Pharmacy and Biomedical Sciences University of Strathclyde Glasgow G4 0RE UK
| |
Collapse
|
36
|
Xie X, Zheng X, Han Z, Chen Y, Zheng Z, Zheng B, He X, Wang Y, Kaplan DL, Li Y, Li G, Wang X, Lan P. A Biodegradable Stent with Surface Functionalization of Combined-Therapy Drugs for Colorectal Cancer. Adv Healthc Mater 2018; 7:e1801213. [PMID: 30468567 DOI: 10.1002/adhm.201801213] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 11/02/2018] [Indexed: 12/11/2022]
Abstract
In-stent restenosis caused by tumor ingrowth is a major problem for patients undergoing stent placement because conventional stents often lack sustainable antitumor capabilities. The aim of this work is to develop a silk fibroin (SF)-based nanofibrous membrane that is loaded with combined-therapy drugs by using electrospinning technologies, which is further coated on a polydioxanone (PDO) stent and used for the treatment of colorectal cancer (CRC). In order to improve treatment effectiveness, a combination of therapeutic drugs, i.e., curcumin (CUR) and 5-fluorouracil (5-FU), is dissolved into SF solution and then eletrospun onto the surface of the PDO stent. The morphology, secondary structure, and in vitro drug release profiles of the membranes are characterized. The antitumor efficacy is assessed in vitro and in vivo using a human CRC cell line and normal cells, and tumor-bearing nude mice. In vitro and in vivo studies on the nanofibrous memembrane-coating demonstrate improved antitumor effects for the CUR/5-FU dual drug system which can be attributed to cell cycle arrest in the S phase in association with induced apoptosis in tumor cells by blocking signal transducer and activator of transcription3 (Stat3) and nuclear factor kappa beta (NF-kB) signaling pathways, suggesting potential in the treatment of CRC in the future.
Collapse
Affiliation(s)
- Xusheng Xie
- National Engineering Laboratory for Modern Silk; College of Textile and Clothing Engineering; Soochow University; Suzhou 215123 P. R. China
| | - Xiaobin Zheng
- Department of Colorectal Surgery; The Sixth Affiliated Hospital of Sun Yat-Sen University; Guangzhou 510655 China
| | - Zhifen Han
- Department of Medical Oncology; Shuguang Hospital; Shanghai University of Traditional Chinese Medicine; Shanghai 201203 China
| | - Yufeng Chen
- Department of Colorectal Surgery; The Sixth Affiliated Hospital of Sun Yat-Sen University; Guangzhou 510655 China
| | - Zhaozhu Zheng
- National Engineering Laboratory for Modern Silk; College of Textile and Clothing Engineering; Soochow University; Suzhou 215123 P. R. China
| | - Bin Zheng
- Department of Colorectal Surgery; The Sixth Affiliated Hospital of Sun Yat-Sen University; Guangzhou 510655 China
| | - Xiaowen He
- Department of Colorectal Surgery; The Sixth Affiliated Hospital of Sun Yat-Sen University; Guangzhou 510655 China
| | - Yongfeng Wang
- National Engineering Laboratory for Modern Silk; College of Textile and Clothing Engineering; Soochow University; Suzhou 215123 P. R. China
| | - David L. Kaplan
- Department of Biomedical Engineering; Tufts University; 4 Colby St Medford MA 02155 USA
| | - Yi Li
- School of Materials; The University of Manchester; Manchester M13 9PL UK
| | - Gang Li
- National Engineering Laboratory for Modern Silk; College of Textile and Clothing Engineering; Soochow University; Suzhou 215123 P. R. China
| | - Xiaoqin Wang
- National Engineering Laboratory for Modern Silk; College of Textile and Clothing Engineering; Soochow University; Suzhou 215123 P. R. China
| | - Ping Lan
- Department of Colorectal Surgery; The Sixth Affiliated Hospital of Sun Yat-Sen University; Guangzhou 510655 China
| |
Collapse
|
37
|
Zhou J, Ying H, Wang M, Su D, Lu G, Chen J. Dual layer collagen-GAG conduit that mimic vascular scaffold and promote blood vessel cells adhesion, proliferation and elongation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 92:447-452. [DOI: 10.1016/j.msec.2018.06.072] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 05/23/2018] [Accepted: 06/30/2018] [Indexed: 01/08/2023]
|
38
|
Carvalho CR, Costa JB, da Silva Morais A, López-Cebral R, Silva-Correia J, Reis RL, Oliveira JM. Tunable Enzymatically Cross-Linked Silk Fibroin Tubular Conduits for Guided Tissue Regeneration. Adv Healthc Mater 2018; 7:e1800186. [PMID: 29999601 DOI: 10.1002/adhm.201800186] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 05/03/2018] [Indexed: 01/11/2023]
Abstract
Hollow tubular conduits (TCs) with tunable architecture and biological properties are in great need for modulating cell functions and drug delivery in guided tissue regeneration. Here, a new methodology to produce enzymatically cross-linked silk fibroin TCs is described, which takes advantage of the tyrosine groups present in silk structure that are known to allow the formation of a covalently cross-linked hydrogel. Three different processing methods are used as a final step to modulate the properties of the silk-based TCs. This approach allows to virtually adjust any characteristic of the final TCs. The final microstructure ranges from a nonporous to a highly porous network, allowing the TCs to be selectively porous to 4 kDa molecules, but not to human skin fibroblasts. Mechanical properties are dependent both on the processing method and thickness of the TCs. Bioactivity is observed after 30 days of immersion in simulated body fluid only for the TCs submitted to a drying processing method (50 °C). The in vivo study performed in mice demonstrates the good biocompatibility of the TCs. The enzymatically cross-linked silk fibroin TCs are versatile and have adjustable characteristics that can be exploited in a variety of biomedical applications, particularly in guidance of peripheral nerve regeneration.
Collapse
Affiliation(s)
- Cristiana R. Carvalho
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
- The Discoveries Centre for Regenerative and Precision Medicine; Headquarters at University of Minho, Avepark; 4805-017 Barco Guimarães Portugal
| | - João B. Costa
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
- The Discoveries Centre for Regenerative and Precision Medicine; Headquarters at University of Minho, Avepark; 4805-017 Barco Guimarães Portugal
| | - Alain da Silva Morais
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
| | - Rita López-Cebral
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
- The Discoveries Centre for Regenerative and Precision Medicine; Headquarters at University of Minho, Avepark; 4805-017 Barco Guimarães Portugal
| | - Joana Silva-Correia
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
| | - Rui L. Reis
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
- The Discoveries Centre for Regenerative and Precision Medicine; Headquarters at University of Minho, Avepark; 4805-017 Barco Guimarães Portugal
| | - J. Miguel Oliveira
- 3B's Research Group; I3Bs-Research Institute on Biomaterials; Biodegradables and Biomimetics; University of Minho; Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine; AvePark, Parque de Ciência e Tecnologia; Zona Industrial da Gandra; 4805-017 Barco Guimarães Portugal
- ICVS/3B's-PT Government Associate Laboratory; Braga Guimarães Portugal
- The Discoveries Centre for Regenerative and Precision Medicine; Headquarters at University of Minho, Avepark; 4805-017 Barco Guimarães Portugal
| |
Collapse
|
39
|
Jirofti N, Mohebbi-Kalhori D, Samimi A, Hadjizadeh A, Kazemzadeh GH. Small-diameter vascular graft using co-electrospun composite PCL/PU nanofibers. Biomed Mater 2018; 13:055014. [DOI: 10.1088/1748-605x/aad4b5] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
40
|
Hielscher D, Kaebisch C, Braun BJV, Gray K, Tobiasch E. Stem Cell Sources and Graft Material for Vascular Tissue Engineering. Stem Cell Rev Rep 2018; 14:642-667. [DOI: 10.1007/s12015-018-9825-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
41
|
Brennan DA, Conte AA, Kanski G, Turkula S, Hu X, Kleiner MT, Beachley V. Mechanical Considerations for Electrospun Nanofibers in Tendon and Ligament Repair. Adv Healthc Mater 2018; 7:e1701277. [PMID: 29603679 DOI: 10.1002/adhm.201701277] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 01/15/2018] [Indexed: 12/22/2022]
Abstract
Electrospun nanofibers possess unique qualities such as nanodiameter, high surface area to volume ratio, biomimetic architecture, and tunable chemical and electrical properties. Numerous studies have demonstrated the potential of nanofibrous architecture to direct cell morphology, migration, and more complex biological processes such as differentiation and extracellular matrix (ECM) deposition through topographical guidance cues. These advantages have created great interest in electrospun fibers for biomedical applications, including tendon and ligament repair. Electrospun nanofibers, despite their nanoscale size, generally exhibit poor mechanical properties compared to larger conventionally manufactured polymer fiber materials. This invites the question of what role electrospun polymer nanofibers can play in tendon and ligament repair applications that have both biological and mechanical requirements. At first glance, the strength and stiffness of electrospun nanofiber grafts appear to be too low to fill the rigorous loading conditions of these tissues. However, there are a number of strategies to enhance and tune the mechanical properties of electrospun nanofiber grafts. As researchers design the next-generation electrospun tendon and ligament grafts, it is critical to consider numerous physiologically relevant mechanical criteria and to evaluate graft mechanical performance in conditions and loading environments that reflect in vivo conditions and surgical fixation methods.
Collapse
Affiliation(s)
- David A. Brennan
- Department of Biomedical Engineering Rowan University 201 Mullica Hill Road, Rowan Hall Glassboro NJ 08028 USA
| | - Adriano A. Conte
- Department of Biomedical Engineering Rowan University 201 Mullica Hill Road, Rowan Hall Glassboro NJ 08028 USA
| | - Gregory Kanski
- Cooper Bone and Joint Institute and Cooper Medical School, Rowan University 3 Cooper Plaza Camden NJ 08103 USA
| | - Stefan Turkula
- Cooper Bone and Joint Institute and Cooper Medical School, Rowan University 3 Cooper Plaza Camden NJ 08103 USA
| | - Xiao Hu
- Department of Biomedical Engineering Rowan University 201 Mullica Hill Road, Rowan Hall Glassboro NJ 08028 USA
- Department of Physics and Astronomy Rowan University 201 Mullica Hill Road, Rowan Hall Glassboro NJ 08028 USA
| | - Matthew T. Kleiner
- Cooper Bone and Joint Institute and Cooper Medical School, Rowan University 3 Cooper Plaza Camden NJ 08103 USA
| | - Vince Beachley
- Department of Biomedical Engineering Rowan University 201 Mullica Hill Road, Rowan Hall Glassboro NJ 08028 USA
| |
Collapse
|
42
|
Wu J, Zhao Y, Wang J, You T, Huang N. Preparation of sulfonated silk fibroin for anti-coagulation material. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2018; 29:1701-1715. [PMID: 29847213 DOI: 10.1080/09205063.2018.1480993] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
Abstracts Here we report the anticoagulant property of Sulfonated Silk Fibroin (SSF) which was improved by sulfonation method. Chlorosulfonic acid was applied to modify the Silk Fibroin (SF) anticoagulant property by the preparation of the SSF. The SSF was prepared in the new technology that 50 °C, 0.2 g SF/ml chlorosulfonic acid and 15 h were optimized with the reaction temperature, special concentration ratio of the SF to the chlorosulfonic acid and the certain reaction time, respectively. Then the SF reaction solution was dialyzed, and freeze-dried to form the SSF. The different properties of the SF and the SSF have been revealed by Fourier Transform Infrared spectroscopy (FTIR), Nuclear Magnetic Resonance (NMR), X-ray Photoelectron Spectrometer (XPS), Gel Permeation Chromatography (GPC), X-ray Diffraction (XRD), Activated Partial Thromboplastin Time (APTT) etc. That the sulfonic acid groups were successfully induced into the SF molecular chains has also been verified. The SSF possessed the excellent performance on the APTT value, and it can be slowly released from the Poly(epsilon-caprolactone) (PCL) composite film. In conclusion, the SSF is the novel product modified by the chlorosulfonic acid directly, and it possesses the good anti-coagulation, resulting in that it can become one of candidates of anti-coagulation materials.
Collapse
Affiliation(s)
- Jianrong Wu
- a Key Laboratory of Advanced Technologies of Materials, Ministry of Education , School of Materials Science and Engineering, Southwest Jiaotong University , Chengdu 610031 , P. R. China
| | - Yuancong Zhao
- a Key Laboratory of Advanced Technologies of Materials, Ministry of Education , School of Materials Science and Engineering, Southwest Jiaotong University , Chengdu 610031 , P. R. China
| | - Jin Wang
- a Key Laboratory of Advanced Technologies of Materials, Ministry of Education , School of Materials Science and Engineering, Southwest Jiaotong University , Chengdu 610031 , P. R. China
| | - Tianxue You
- a Key Laboratory of Advanced Technologies of Materials, Ministry of Education , School of Materials Science and Engineering, Southwest Jiaotong University , Chengdu 610031 , P. R. China
| | - Nan Huang
- a Key Laboratory of Advanced Technologies of Materials, Ministry of Education , School of Materials Science and Engineering, Southwest Jiaotong University , Chengdu 610031 , P. R. China
| |
Collapse
|
43
|
Carrabba M, Madeddu P. Current Strategies for the Manufacture of Small Size Tissue Engineering Vascular Grafts. Front Bioeng Biotechnol 2018; 6:41. [PMID: 29721495 PMCID: PMC5916236 DOI: 10.3389/fbioe.2018.00041] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 03/23/2018] [Indexed: 01/12/2023] Open
Abstract
Occlusive arterial disease, including coronary heart disease (CHD) and peripheral arterial disease (PAD), is the main cause of death, with an annual mortality incidence predicted to rise to 23.3 million worldwide by 2030. Current revascularization techniques consist of angioplasty, placement of a stent, or surgical bypass grafting. Autologous vessels, such as the saphenous vein and internal thoracic artery, represent the gold standard grafts for small-diameter vessels. However, they require invasive harvesting and are often unavailable. Synthetic vascular grafts represent an alternative to autologous vessels. These grafts have shown satisfactory long-term results for replacement of large- and medium-diameter arteries, such as the carotid or common femoral artery, but have poor patency rates when applied to small-diameter vessels, such as coronary arteries and arteries below the knee. Considering the limitations of current vascular bypass conduits, a tissue-engineered vascular graft (TEVG) with the ability to grow, remodel, and repair in vivo presents a potential solution for the future of vascular surgery. Here, we review the different methods that research groups have been investigating to create TEVGs in the last decades. We focus on the techniques employed in the manufacturing process of the grafts and categorize the approaches as scaffold-based (synthetic, natural, or hybrid) or self-assembled (cell-sheet, microtissue aggregation and bioprinting). Moreover, we highlight the attempts made so far to translate this new strategy from the bench to the bedside.
Collapse
Affiliation(s)
- Michele Carrabba
- School of Clinical Sciences, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Paolo Madeddu
- School of Clinical Sciences, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| |
Collapse
|
44
|
Yu E, Mi HY, Zhang J, Thomson JA, Turng LS. Development of biomimetic thermoplastic polyurethane/fibroin small-diameter vascular grafts via a novel electrospinning approach. J Biomed Mater Res A 2018; 106:985-996. [PMID: 29143442 PMCID: PMC5826852 DOI: 10.1002/jbm.a.36297] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Revised: 10/28/2017] [Accepted: 11/10/2017] [Indexed: 12/18/2022]
Abstract
A new electrospinning approach for fabricating vascular grafts with a layered, circumferentially aligned, and micro-wavy fibrous structure similar to natural elastic tissues has been developed. The customized electrospinning collector was able to generate wavy fibers using the dynamic "jump rope" collecting process, which also solved the sample removal problem for mandrel-type collectors. In this study, natural silk fibroin and synthetic thermoplastic polyurethane (TPU) were combined at different weight ratios to produce hybrid small-diameter vascular grafts. The purpose of combining these two materials was to leverage the bioactivity and tunable mechanical properties of these natural and synthetic materials. Results showed that the electrospun fiber morphology was highly influenced by the material compositions and solvents employed. All of the TPU/fibroin hybrid grafts had mechanical properties comparable to natural blood vessels. The circumferentially aligned and wavy biomimetic configuration provided the grafts with a sufficient toe region and the capacity for long-term usage under repeated dilatation and contraction. Cell culture tests with human endothelial cells (EC) also revealed high cell viability and good biocompatibility for these grafts. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 985-996, 2018.
Collapse
Affiliation(s)
- Emily Yu
- Department of Mechanical Engineering, University of Wisconsin–Madison, WI, USA, 53706
- Wisconsin Institute for Discovery, University of Wisconsin–Madison, WI, USA, 53715
| | - Hao-Yang Mi
- Department of Mechanical Engineering, University of Wisconsin–Madison, WI, USA, 53706
- Wisconsin Institute for Discovery, University of Wisconsin–Madison, WI, USA, 53715
- Department of Industrial Equipment and Control Engineering, South China University of Technology, Guangzhou, China
| | - Jue Zhang
- Morgridge Institute for Research, WI, USA, 53715
| | | | - Lih-Sheng Turng
- Department of Mechanical Engineering, University of Wisconsin–Madison, WI, USA, 53706
- Wisconsin Institute for Discovery, University of Wisconsin–Madison, WI, USA, 53715
| |
Collapse
|
45
|
Awad NK, Niu H, Ali U, Morsi YS, Lin T. Electrospun Fibrous Scaffolds for Small-Diameter Blood Vessels: A Review. MEMBRANES 2018; 8:E15. [PMID: 29509698 PMCID: PMC5872197 DOI: 10.3390/membranes8010015] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Revised: 01/31/2018] [Accepted: 02/28/2018] [Indexed: 11/24/2022]
Abstract
Small-diameter blood vessels (SDBVs) are still a challenging task to prepare due to the occurrence of thrombosis formation, intimal hyperplasia, and aneurysmal dilation. Electrospinning technique, as a promising tissue engineering approach, can fabricate polymer fibrous scaffolds that satisfy requirements on the construction of extracellular matrix (ECM) of native blood vessel and promote the adhesion, proliferation, and growth of cells. In this review, we summarize the polymers that are deployed for the fabrication of SDBVs and classify them into three categories, synthetic polymers, natural polymers, and hybrid polymers. Furthermore, the biomechanical properties and the biological activities of the electrospun SBVs including anti-thrombogenic ability and cell response are discussed. Polymer blends seem to be a strategic way to fabricate SDBVs because it combines both suitable biomechanical properties coming from synthetic polymers and favorable sites to cell attachment coming from natural polymers.
Collapse
Affiliation(s)
- Nasser K Awad
- Biomechanics and Tissue Engineering Group, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
- Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
- Electrochemistry and Corrosion Laboratory, National Research Centre, Dokki, Cairo 12422, Egypt.
| | - Haitao Niu
- Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
| | - Usman Ali
- Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
- College of Textile Engineering, Bahauddin Zakariya University, Multan 60800, Pakistan.
| | - Yosry S Morsi
- Biomechanics and Tissue Engineering Group, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
| | - Tong Lin
- Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
| |
Collapse
|
46
|
Filipe EC, Santos M, Hung J, Lee BS, Yang N, Chan AH, Ng MK, Rnjak-Kovacina J, Wise SG. Rapid Endothelialization of Off-the-Shelf Small Diameter Silk Vascular Grafts. JACC Basic Transl Sci 2018; 3:38-53. [PMID: 30062193 PMCID: PMC6058932 DOI: 10.1016/j.jacbts.2017.12.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 12/13/2017] [Accepted: 12/15/2017] [Indexed: 12/12/2022]
Abstract
Synthetic vascular grafts for small diameter revascularization are lacking. Clinically available conduits expanded polytetrafluorethylene and Dacron fail acutely due to thrombosis and in the longer term from neointimal hyperplasia. We report the bioengineering of a cell-free, silk-based vascular graft. In vitro we demonstrate strong, elastic silk conduits that support rapid endothelial cell attachment and spreading while simultaneously resisting blood clot and fibrin network formation. In vivo rat studies show complete graft patency at all time points, rapid endothelialization, and stabilization and contraction of neointimal hyperplasia. These studies show the potential of silk as an off-the-shelf small diameter vascular graft.
Collapse
Affiliation(s)
- Elysse C. Filipe
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Miguel Santos
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Juichien Hung
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
| | - Bob S.L. Lee
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Nianji Yang
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Alex H.P. Chan
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Martin K.C. Ng
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Department of Cardiology, Royal Prince Alfred Hospital, Camperdown, New South Wales, Australia
| | - Jelena Rnjak-Kovacina
- Graduate School of Biomedical Engineering, University of New South Wales–Sydney, Sydney, New South Wales, Australia
| | - Steven G. Wise
- Applied Materials Group, The Heart Research Institute, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
47
|
|
48
|
Khodadoust M, Mohebbi-Kalhori D, Jirofti N. Fabrication and Characterization of Electrospun Bi-Hybrid PU/PET Scaffolds for Small-Diameter Vascular Grafts Applications. Cardiovasc Eng Technol 2017; 9:73-83. [PMID: 29196952 DOI: 10.1007/s13239-017-0338-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2017] [Accepted: 11/18/2017] [Indexed: 11/27/2022]
Abstract
In spite of advances have been made during the past decades, the problems associated with small-diameter vascular grafts, including low patency and compliance mismatch and in consequence of that thrombosis, aneurysm and intimal hyperplasia are still challenges. To address these problems, net polyurethane (PU) and poly (ethylene terephthalate) (PET) polymers and hybrid PU/PET were electrospun to create three different types of small-diameter vascular scaffolds due to their unique physicochemical characteristics: PU, PET, and novel hybrid PU/PET scaffolds. The results show that the PU and PET composite can improve the mechanical properties of the tissue-engineered vascular scaffolds in the range of the native vessels where the non-cytotoxicity characteristic of these well-known polymers is still immutable. The compliance and stiffness factor of the fabricated hybrid scaffolds were 4.468 ± 0.177 and 22.718 ± 0.896%/0.01 mmHg, respectively, which were significantly different with that of the net PU and PET electrospun scaffolds. Other properties such as ultimate tensile stress (UTS) (3.56 ± 1.21 MPa) were also in good accordance with the native vessels. Furthermore, FT-IR analysis testified the presence of both PU and PET in the hybrid scaffolds. Overall, we were able to fabricate a hybrid scaffold as a small-diameter vascular graft that mechanically matched the gold standard of blood vessel substitution.
Collapse
Affiliation(s)
- Marziyeh Khodadoust
- Chemical Engineering Department, University of Sistan and Baluchestan, Zahedan, Iran
| | - Davod Mohebbi-Kalhori
- Chemical Engineering Department, University of Sistan and Baluchestan, Zahedan, Iran. .,Institute of Nanotechnology, University of Sistan and Baluchestan, Zahedan, Iran. .,University of Sistan and Baluchestan Central Laboratory, Zahedan, Iran.
| | - Nafiseh Jirofti
- Chemical Engineering Department, University of Sistan and Baluchestan, Zahedan, Iran
| |
Collapse
|
49
|
Chiarini A, Freddi G, Liu D, Armato U, Dal Prà I. Biocompatible Silk Noil-Based Three-Dimensional Carded-Needled Nonwoven Scaffolds Guide the Engineering of Novel Skin Connective Tissue. Tissue Eng Part A 2017; 22:1047-60. [PMID: 27411949 DOI: 10.1089/ten.tea.2016.0124] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Retracting hypertrophic scars resulting from healed burn wounds heavily impact on the patients' life quality. Biomaterial scaffolds guiding burned-out skin regeneration could suppress or lessen scar retraction. Here we report a novel silk noil-based three-dimensional (3D) nonwoven scaffold produced by carding and needling with no formic acid exposure, which might improve burn healing. Once wetted, it displays human skin-like physical features and a high biocompatibility. Human keratinocyte-like cervical carcinoma C4-I cells seeded onto the carded-needled nonwovens in vitro quickly adhered to them, grew, and actively metabolized glutamine releasing lactate. As on plastic, they released no proinflammatory IL-1β, although secreting tumor necrosis factor-alpha, an inducer of the autocrine mitogen amphiregulin in such cells. Once grafted into interscapular subcutaneous tissue of mice, carded-needled nonwovens guided the afresh assembly of a connective tissue enveloping the fibroin microfibers and filling the interposed voids within 3 months. Fibroblasts and a few poly- or mononucleated macrophages populated the engineered tissue. Besides, its extracellular matrix contained thin sparse collagen fibrils and a newly formed vascular network whose endothelin-1-expressing endothelial cells grew first on the fibroin microfibrils and later expanded into the intervening matrix. Remarkably, no infiltrates of inflammatory leukocytes and no packed collagen fibers bundles among fibroin microfibers, no fibrous capsules at the grafts periphery, and hence no foreign body response was obtained at the end of 3 months of observation. Therefore, we posit that silk noil-based 3D carded-needled nonwoven scaffolds are tools for translational medicine studies as they could guide connective tissue regeneration at deep burn wounds averting scar retraction with good functional results.
Collapse
Affiliation(s)
- Anna Chiarini
- 1 Human Histology and Embryology Unit, University of Verona Medical School , Verona, Italy
| | | | - Daisong Liu
- 3 Burns Institute, Third Military Medical University , Chongqing, China
| | - Ubaldo Armato
- 1 Human Histology and Embryology Unit, University of Verona Medical School , Verona, Italy
| | - Ilaria Dal Prà
- 1 Human Histology and Embryology Unit, University of Verona Medical School , Verona, Italy
| |
Collapse
|
50
|
Effect of molecular weight on electro-spinning performance of regenerated silk. Int J Biol Macromol 2017; 106:1166-1172. [PMID: 28847607 DOI: 10.1016/j.ijbiomac.2017.08.115] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 08/19/2017] [Accepted: 08/21/2017] [Indexed: 11/22/2022]
Abstract
Owing to the excellent biocompatibility of silk fibroins (SFs) and ease of fabrication of nano-fibrous webs by the electro-spinning technique, electro-spun SF webs have attracted the attention of researchers for various biomedical applications, including their use as tissue engineering scaffolds and membranes for guided bone regeneration. In this work, the effect of the molecular weight (MW) and concentration of SFs on the structure and properties of the electro-spun SF webs was examined. The fiber morphology and porosity of these SF webs were strongly affected by the viscosity of the SF dope solution. It was found that the electro-spinning rate of the SF solution could be increased significantly (7.5 fold) by controlling the MW and concentration of the SF. Interestingly, as the SF MW and concentration (i.e., solution viscosity) increased, the extent of β-sheet crystallization of the SF decreased, leading to a decrease in the overall crystallinity. The strength and elongation of the electro-spun SF web decreased with an increase in the web porosity (i.e., increasing SF concentration) and a decrease in the MW of the SF.
Collapse
|