1
|
Alghauli MA, Almuzaini S, Aljohani R, Alqutaibi AY. Influence of 3D printing orientations on physico-mechanical properties and accuracy of additively manufactured dental ceramics. J Prosthodont Res 2025; 69:181-202. [PMID: 39756936 DOI: 10.2186/jpr.jpr_d_24_00092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
Abstract
PURPOSE This systematic review aims to assess the impact of different 3D printing orientations on the physico-mechanical properties, volumetric change, and accuracy of additively manufactured ceramic specimens, as well as their restorations. STUDY SELECTION The web database containing records for building orientation of 3D-printed ceramics until January 2024 was searched, with no language limitations. PRISMA 2020 guidelines were followed, and the risk of bias was evaluated using the modified CONSORT checklist for laboratory studies on dental materials. The RevMan 5.4 of Cochrane collaboration was used for the meta-analysis with α<0.05. RESULTS In this systematic review, 35 out of 2967 records were considered. The printing orientations had a significant influence on the mechanical properties of the additively manufactured specimens (P < 0.05), specifically, the horizontally printed specimens exhibited the best mechanical behavior, while the physical properties exhibited controversial results. Additionally, the printing orientations had a significant impact on the volumetric shrinkage and accuracy of molar teeth (P < 0.05). CONCLUSIONS The ideal mechanical outcome was observed when ceramic specimens were 3D-printed in a horizontal direction relative to the platform, while vertically printed specimens showed the worst properties. The printing orientations affect the volumetric change of the specimens; however, volumetric change highly depends on the sintering parameters. It is recommended to 3D print ceramic molar crowns at 180° with the occlusal surface facing the printing platform. CLINICAL SIGNIFICANCE Several factors affect the additively manufactured restorations throughout the printing procedure. Therefore, printing orientation should be carefully considered before the additive production process of ceramic restorations.
Collapse
Affiliation(s)
| | - Sarah Almuzaini
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Rola Aljohani
- College of Dentistry, Taibah University, Al-Madinah, Saudia Arabia
| | - Ahmed Yaseen Alqutaibi
- Substitutive Dental Science Department, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
- Prosthodontics Department, College of Dentistry, Ibb University, Ibb, Yemen
| |
Collapse
|
2
|
Juntavee N, Juntavee A, Jaralpong C. Color Characteristics of High Yttrium Oxide-Doped Monochrome and Multilayer Partially Stabilized Zirconia upon Different Sintering Parameters. Eur J Dent 2025; 19:227-239. [PMID: 38942053 PMCID: PMC11750310 DOI: 10.1055/s-0044-1787700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/30/2024] Open
Abstract
OBJECTIVES Sintering influences the optical properties of zirconia. This study examined the effect of altering sintering temperature and time of monochrome (Mo) and multilayer (Mu) 5 mol% yttria-partially stabilized zirconia (5Y-PSZ) on color characteristics. MATERIALS AND METHODS Three hundred specimens (width × length × thickness = 10 × 20 × 2 mm) were prepared from Mo and Mu (with cervical [C], middle [M], and incisal [I] region) 5Y-PSZ and randomly sintered at decreasing (Td: 1,450°C), regular (Tr: 1,500°C), and increasing (TI: 1,550°C) sintering temperature, with extremely short (He: 10 minutes), ultrashort (Hu: 15 minutes), short (Hs: 30 minutes), and regular (Hr: 135 minutes) sintering time (n = 15/group). Color appearance (EW ), translucency parameter (TP), contrast ratio (CR), opalescence parameter (OP), and color appearance difference (∆E diff) were evaluated in the CIE L*a*b* system. Microstructures were evaluated by scanning electron microscope (SEM) and X-ray diffractometer (XRD). STATISTICAL ANALYSIS Analysis of variance (ANOVA) and Bonferroni comparisons were determined for significant differences (p < 0.05). RESULTS Significant differences in color parameters upon zirconia type, sintering temperature, and sintering time, and their interactions were indicated (p < 0.05). Increasing sintering temperature and extended sintered time resulted in larger grain, reduced tetragonal-to-monoclinic phase transformation, and significantly increased the TP and OP, but decreased the CR and ∆E diff (p < 0.05). Decreasing sintering temperature and time led to clinically unacceptable color appearance. CONCLUSION Mo was found to be more translucent than Mu. To achieve the most favorable optical properties, increasing sintering temperature and extending sintering time are recommended. Decreasing sintering temperature is not suggested. However, shortened sintering time is feasible, but it needs sintering with increasing sintering temperature to achieve a promising color appearance.
Collapse
Affiliation(s)
- Niwut Juntavee
- Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Apa Juntavee
- Department of Preventive Dentistry, Division of Pediatric Dentistry, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Chutikarn Jaralpong
- Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
3
|
Mayinger F, Ender A, Strickstrock M, Elsayed A, Nassary Zadeh P, Zimmermann M, Stawarczyk B. Impact of the sintering parameters on the grain size, crystal phases, translucency, biaxial flexural strength, and fracture load of zirconia materials. J Mech Behav Biomed Mater 2024; 155:106580. [PMID: 38759588 DOI: 10.1016/j.jmbbm.2024.106580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 05/06/2024] [Accepted: 05/10/2024] [Indexed: 05/19/2024]
Abstract
OBJECTIVES To investigate the influence of the zirconia and sintering parameters on the optical and mechanical properties. METHODS Three zirconia materials (3/4Y-TZP, 4Y-TZP, 3Y-TZP) were high-speed (HSS), speed (SS) or conventionally (CS) sintered. Disc-shaped specimens nested in 4 vertical layers of the blank were examined for grain size (GS), crystal phases (c/t'/t/m-phase), translucency (T), and biaxial flexural strength. Fracture load (FL) of three-unit fixed dental prostheses was determined initially and after thermomechanical aging. Fracture types were classified, and data statistically analyzed. RESULTS 4Y-TZP showed a higher amount of c + t'-phase and lower amount of t-phase, and higher optical and lower mechanical properties than 3Y-TZP. In all materials, T declined from Layer 1 to 4. 3/4Y-TZP showed the highest FL, followed by 3Y-TZP, while 4Y-TZP showed the lowest. In 4Y-TZP, the sintering parameters exercised a direct impact on GS and T, while mechanical properties were largely unaffected. The sintering parameters showed a varying influence on 3Y-TZP. Thermomechanical aging resulted in comparable or higher FL. CONCLUSION 3/4Y-TZP presenting the highest FL underscores the principle of using strength-gradient multi-layer blanks to profit from high optical properties in the incisal area, while ensuring high mechanical properties in the lower areas subject to tensile forces. With all groups exceeding maximum bite forces, the examined three-unit FDPs showed promising long-term mechanical properties.
Collapse
Affiliation(s)
- Felicitas Mayinger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Andreas Ender
- Division of Computerized Restorative Dentistry, Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Monika Strickstrock
- Faculty of Engineering and Computer Science, Material Science and Analysis, University of Applied Sciences Osnabrück, Albrechtstraße 30, 49076, Osnabrück, Germany
| | - Adham Elsayed
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Parissa Nassary Zadeh
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Marcus Zimmermann
- Division of Computerized Restorative Dentistry, Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
4
|
Juntavee N, Juntavee A, Jaralpong C. Flexural Strength of Two Multilayered and Monochromatic High Yttria Containing Zirconia Materials Following Different Sintering Parameters. Eur J Dent 2024; 18:551-562. [PMID: 37729931 PMCID: PMC11132776 DOI: 10.1055/s-0043-1772569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023] Open
Abstract
OBJECTIVES Sintering parameters influence the properties of zirconia. This study examined the effect of altering sintering temperature and time of monochrome and multilayer 5 mol% yttria-partially stabilized zirconia (5Y-PSZ) on flexural strength. MATERIALS AND METHODS Three hundred specimens (width × length × thickness = 10 × 20 × 2 mm) were prepared from monolayer (ZX) and multilayer (ZM) 5Y-PSZ and randomly sintered at decreasing (TD: 1,450°C), regular (TR: 1,500°C), and increasing (TI: 1,550°C) sintering temperature, with extremely short (HE: 10 minutes), ultrashort (HU: 15 minutes), short (HS: 30 minutes), and regular (HR: 135 minutes) sintering time (n = 15/group). The precrack was induced on the tension side before testing for flexural strength (σ). STATISTICAL ANALYSIS Analysis of variance and Tukey's test were used for significant differences of σ at p < 0.05. The microstructure and crystalline (monoclinic; m, tetragonal; t, cubic; c) phase were evaluated by scanning electron microscope (SEM) and X-ray diffractometer (XRD). RESULTS ZXTIHS indicated the highest σ for ZX (315.81 ± 18.91 MPa), whereas ZMTIHS indicated the highest σ for ZM (335.21 ± 36.18 MPa). There was no significant difference for σ between ZX and ZM (p > 0.05). Sintering zirconia at TI or HR indicated significantly higher σ than sintering at TD or TR or with HS, HE, or HU for both ZX and ZM (p < 0.05). There was no significant difference for σ between TRHR and TIHS, TIHU, and TIHE (p > 0.05). SEM indicated intergranular and transgranular fractures. XRD revealed predominately c- and t-phases and minor amounts of m-phase. CONCLUSION Increasing sintered temperature with decreasing time offers acceptable strength to regular sintering. Raising sintering temperature with decreasing time is suggested to facilitate chairside restorative reconstruction.
Collapse
Affiliation(s)
- Niwut Juntavee
- Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Apa Juntavee
- Division of Pediatric Dentistry, Department of Preventive Dentistry, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Chutikarn Jaralpong
- Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
5
|
Alshahrani AM, Lim CH, Wolff MS, Janal MN, Zhang Y. Current speed sintering and high-speed sintering protocols compromise the translucency but not strength of yttria-stabilized zirconia. Dent Mater 2024; 40:664-673. [PMID: 38378371 PMCID: PMC11015968 DOI: 10.1016/j.dental.2024.02.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 01/05/2024] [Accepted: 02/12/2024] [Indexed: 02/22/2024]
Abstract
OBJECTIVES To investigate the impacts of speed and high-speed sintering on the densification, microstructure, phase composition, translucency, and flexural strength of yttria-stabilized zirconia (YSZ). METHODS A total of 162 disc-shaped specimens (n = 18) were cold-isostatically pressed from 3YSZ (Zpex), 4YSZ (Zpex 4), and 5YSZ (Zpex Smile) powders (Tosoh Corporation) and sintered according to the following protocols: conventional (control, ∼12 h), speed (∼28 min for 3YSZ; ∼60 min for 4YSZ and 5YSZ), and high-speed (∼18 min) sintering. Dimensions of zirconia specimens after sintering and polishing (1-μm diamond grit finish) were Ø13.75 × 1 mm. Density, microstructure, phase content, translucency parameter, and biaxial flexural strength were evaluated using Archimedes', SEM, XRD, spectrophotometric, and piston-on-3-ball methods, respectively. Data were analyzed with either one-way ANOVA and Tukey's test or Kruskal-Wallis with Dunn's test (α = 0.05). RESULTS For all YSZ compositions, conventional sintering yielded the highest density followed by speed then high-speed sintering. All sintering protocols resulted in similar strength values; however, speed and high-speed sintering protocols afforded significantly lower translucency relative to conventional sintering. XRD analysis revealed similar spectra for YSZs sintered by various protocols. The speed sintered specimens had the smallest grain size whereas the high-speed sintered 5YSZ possessed the largest grain size among all groups. SEM examination of all YSZ compositions revealed that the average pore size was an order of magnitude smaller than the average grain size. SIGNIFICANCE Speed and high-speed sintering of YSZs yield similar strength but diminished density and translucency relative to their conventionally sintered counterparts.
Collapse
Affiliation(s)
- Abdulaziz M Alshahrani
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Chek Hai Lim
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Mark S Wolff
- Morton Amsterdam Dean, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Malvin N Janal
- Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, NY 10010, USA
| | - Yu Zhang
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
6
|
Molinero-Mourelle P, Abou-Ayash S, Brägger U, Schimmel M, Özcan M, Yilmaz B, Buser R, Al-Haj Husain N. Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study. J Mech Behav Biomed Mater 2024; 151:106395. [PMID: 38244420 DOI: 10.1016/j.jmbbm.2024.106395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 01/08/2024] [Accepted: 01/08/2024] [Indexed: 01/22/2024]
Abstract
OBJECTIVES To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Urs Brägger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Switzerland
| | - Mutlu Özcan
- Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, OH, USA
| | - Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Nadin Al-Haj Husain
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland; Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
7
|
Liu H, Inokoshi M, Xu K, Tonprasong W, Minakuchi S, Van Meerbeek B, Vleugels J, Zhang F. Does speed-sintering affect the optical and mechanical properties of yttria-stabilized zirconia? A systematic review and meta-analysis of in-vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2023; 59:312-328. [PMID: 37705876 PMCID: PMC10495607 DOI: 10.1016/j.jdsr.2023.08.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/02/2023] [Accepted: 08/22/2023] [Indexed: 09/15/2023] Open
Abstract
Zirconia restorations are increasingly popular in dental treatment. Yttria-stabilized zirconia (YSZ) needs to be sintered for clinical applications and novel speed-sintering protocols are being developed for chairside treatments. Whether the properties of speed-sintered YSZ meet clinical requirements, however, remains unclear. Therefore, we conducted a systematic review and meta-analysis on the influence of speed-sintering on the optical and mechanical properties of dental YSZ according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. A literature search was conducted using PubMed, Embase, and Web of Science databases for relevant articles published between January 1, 2010 and February 28, 2022 in English, Chinese, or Japanese. After full-text evaluation and quality assessment, 26 articles were selected. Meta-analysis revealed that speed-sintering does not significantly affect the CIEDE2000-based translucency parameter, contrast ratio, three-point flexural strength, biaxial flexural strength, or fracture toughness of YSZ (p < 0.01) compared to conventional sintering. However, the CIELab-based translucency parameter of conventionally sintered YSZ is higher than that of speed-sintered YSZ. The descriptive analysis indicated that speed-sintering does not affect the hardness of YSZ compared to that of conventionally sintered YSZ. The results indicate that speed-sintering is suitable for preparing YSZ for dental restorations.
Collapse
Affiliation(s)
- Hengyi Liu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Kaiqi Xu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Watcharapong Tonprasong
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 blok a, B-3000 Leuven, Belgium
| | - Jef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Kasteelpark Arenberg 44, BE-3001 Leuven, Belgium
| | - Fei Zhang
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 blok a, B-3000 Leuven, Belgium
- KU Leuven (University of Leuven), Department of Materials Engineering, Kasteelpark Arenberg 44, BE-3001 Leuven, Belgium
| |
Collapse
|
8
|
Attia MA, Radwan M, Blunt L, Bills P, Tawfik A, Arafa AM. Effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia fixed partial dentures: An in vitro study. J Prosthet Dent 2023; 130:908.e1-908.e8. [PMID: 37802734 DOI: 10.1016/j.prosdent.2023.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/12/2023] [Accepted: 09/13/2023] [Indexed: 10/08/2023]
Abstract
STATEMENT OF PROBLEM Strength-gradient zirconia combining 3 zirconia formulations with different flexural strengths has been reported to have outstanding mechanical properties. However, data concerning the effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia fixed partial dentures (FPDs) are sparse. PURPOSE The purpose of this in vitro study was to test the effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia FPDs. MATERIAL AND METHODS Two custom-made stainless-steel master dies were designed to replicate a mandibular right second premolar and second molar prepared to receive a 3-unit monolithic zirconia FPD. Thirty monolithic zirconia FPDs were milled from gradient zirconia blanks and allocated to 3 groups (n=10) according to the sintering protocols: high-speed sintering, speed sintering, and conventional sintering. The FPDs were cemented onto the corresponding dies with traditional glass ionomer cement. All FPDs were cyclic loaded (600 000 cycles/49 N/1.7 Hz) in a mastication simulator. Fracture load measurements for each FPD were determined by using a universal testing machine. Scanning electron microscopy (SEM) at ×80 magnification was used to examine a fractured FPD from each group. A representative specimen from each group was examined with SEM at ×30 000 magnification to determine the grain size. One-way ANOVA, pair-wise Tukey honestly significant difference (HSD), and Pearson correlation tests were used for statistical analysis of the data (α=.05). RESULTS The high-speed sintered FPDs recorded the highest statistically significant fracture load mean ±standard deviation value (2526 ±300 N), followed by the speed sintered FPDs (2136 ±127 N), while the lowest statistically significant fracture load mean value was recorded with the conventionally sintered FPDs (1361 ±181 N) (P<.001). In addition, the mean ±standard deviation grain size values were 488 ±272 nm for the high-speed sintered specimen, 578 ±409 nm for the speed sintered specimen, and 832 ±551 nm for the conventionally sintered specimen (P<.001). A significant negative correlation was found between fracture strength and grain size among the 3 groups. CONCLUSIONS The fracture strength of 3-unit monolithic gradient zirconia FPDs sintered by using a high-speed protocol was significantly higher than that of speed and conventionally sintered FPDs (P<.001). The high-speed sintering protocol reduced the mean grain size of gradient zirconia FPDs compared with that of both speed and conventional sintering protocols.
Collapse
Affiliation(s)
- Mazen A Attia
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt.
| | - Mohamed Radwan
- Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
| | - Liam Blunt
- Professor, Engineering and Physical Sciences Research Council (EPSRC) Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, England, United Kingdom
| | - Paul Bills
- Professor, Engineering and Physical Sciences Research Council (EPSRC) Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, England, United Kingdom
| | - Ahmed Tawfik
- PhD Researcher, Engineering and Physical Sciences Research Council (EPSRC) Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, England, United Kingdom
| | - Ahmed M Arafa
- Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
| |
Collapse
|
9
|
Kui A, Manziuc M, Petruțiu A, Buduru S, Labuneț A, Negucioiu M, Chisnoiu A. Translucent Zirconia in Fixed Prosthodontics-An Integrative Overview. Biomedicines 2023; 11:3116. [PMID: 38137337 PMCID: PMC10740999 DOI: 10.3390/biomedicines11123116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/12/2023] [Accepted: 11/15/2023] [Indexed: 12/24/2023] Open
Abstract
Over the past two decades, dental ceramics have experienced rapid advances in science and technology, becoming the fastest-growing field of dental materials. This review emphasizes the significant impact of translucent zirconia in fixed prosthodontics, merging aesthetics with strength, and highlights its versatility from single crowns to complex bridgework facilitated by digital manufacturing advancements. The unique light-conducting properties of translucent zirconia offer a natural dental appearance, though with considerations regarding strength trade-offs compared to its traditional, opaque counterpart. The analysis extends to the mechanical attributes of the material, noting its commendable fracture resistance and durability, even under simulated physiological conditions. Various zirconia types (3Y-TZP, 4Y-TZP, 5Y-TZP) display a range of strengths influenced by factors like yttria content and manufacturing processes. The study also explores adhesive strategies, underlining the importance of surface treatments and modern adhesives in achieving long-lasting bonds. In the realm of implant-supported restorations, translucent zirconia stands out for its precision, reliability, and aesthetic adaptability, proving suitable for comprehensive dental restorations. Despite its established benefits, the review calls for ongoing research to further refine the material's properties and adhesive protocols and to solidify its applicability through long-term clinical evaluations, ensuring its sustainable future in dental restorative applications.
Collapse
Affiliation(s)
- Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Manuela Manziuc
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Adrian Petruțiu
- Oral Rehabilitation Department, Iuliu Hatieganu University of Medicine and Pharmacy, 13 Victor Babes Street, 400008 Cluj-Napoca, Romania
| | - Smaranda Buduru
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Anca Labuneț
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Marius Negucioiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Andrea Chisnoiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| |
Collapse
|
10
|
Lubauer J, Schuenemann FH, Belli R, Lohbauer U. Speed-sintering and the mechanical properties of 3-5 mol% Y 2O 3-stabilized zirconias. Odontology 2023; 111:883-890. [PMID: 36859729 PMCID: PMC10492746 DOI: 10.1007/s10266-023-00796-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 02/15/2023] [Indexed: 03/03/2023]
Abstract
Ever faster workflows for the fabrication of all-ceramic restorations are of high economic interest. For that purpose, sintering protocols have been optimized for use in modern sintering furnaces, the so-called speed-sintering. However, conventional furnaces are still the most widely used equipment to sinter zirconia restorations. In this in-vitro study, we evaluated the feasibility of a speed-sintering protocol using a conventional sintering furnace to sinter different dental zirconias (stabilized with 3 mol% up to 5.4 mol% Y2O3) in comparison to a conventional sintering program. The properties evaluated were Young's modulus, Poisson's ratio, density, biaxial flexural strength, and fracture toughness. We show here that despite differences being dependent on material, the physical and mechanical properties of speed-sintered zirconia are comparable to those obtained by the conventional sintering.
Collapse
Affiliation(s)
- Julia Lubauer
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany
| | - Fernanda Haverroth Schuenemann
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany
| | - Renan Belli
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany.
| | - Ulrich Lohbauer
- Zahnklinik 1-Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Glueckstraße 11, 91054, Erlangen, Germany
| |
Collapse
|
11
|
Antón X, Liebermann A, Hampe R, Joda T, Stawarczyk B. Impact of high-speed sintering and choice of preshaded monochrome or multilayered blanks on fatigue behavior of 4 mol% yttria-stabilized tetragonal zirconia polycrystal. J Prosthet Dent 2023; 130:639-645. [PMID: 34930599 DOI: 10.1016/j.prosdent.2021.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 10/31/2021] [Accepted: 11/01/2021] [Indexed: 11/25/2022]
Abstract
STATEMENT OF PROBLEM High-speed sintering allows the rapid fabrication of esthetic restorations with adequate flexural strength. However, data on the fatigue behavior of high-speed sintered 4 mol% yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP) are lacking. PURPOSE The purpose of this in vitro study was to examine the effect of high-speed sintering and the preshading of blanks (monochrome versus multilayer) on the fatigue behavior of 4Y-TZP ceramics. MATERIAL AND METHODS Four-point flexural strength specimens (N=405) were fabricated from high-speed sintered multilayer 4Y-TZP (Zolid DRS) processed at 1580 °C for about 20 minutes and conventionally sintered at 1450 °C for about 10 hours, multilayer 4Y-TZP (Zolid Gen-x), and monochrome 4Y-TZP (Ceramill Zolid HT+PS), the control group. The specimens were loaded under 5 different dynamic test conditions for fatigue testing (P1-P5). Three were step-stress protocols (P1: 50 N for 5000 cycles; P2: 10 N for 1000 cycles, P3: 5% for 5000 cycles), 1 was tested with a constant force of 720 N (P4), and 1 was tested for different constant load levels (P5). For analysis of P1-P3, the Kaplan-Meier test and Mantel Cox test were performed (α=.05). P4 was analyzed with the Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U tests, and P5 by creating a load-cycle diagram. A fracture analysis was performed. RESULTS ZMLC showed better fatigue behavior than ZMLH (P≤.006) and ZMOC (P≤.002) in all 3 step-stress protocols (P1-P3). ZMLH showed results comparable with those for ZMOC (P≥.285). In P4 and P5, all materials showed comparable values (P=.163 for P4). CONCLUSIONS The multilayer technique showed a positive effect on the fatigue behavior of 4Y-TZP. In contrast, high-speed sintering negatively influenced the fatigue behavior of multilayer 4Y-TZP. The high-speed sintered material showed no deterioration compared with the conventional sintered monochrome material.
Collapse
Affiliation(s)
- Xenia Antón
- Doctoral student, Dental Materials Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany.
| | - Anja Liebermann
- Assistant Professor, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Rüdiger Hampe
- Guest Researcher, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Tim Joda
- Professor, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Bogna Stawarczyk
- Scientific Head, Dental Materials Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
12
|
Packaeser MG, Aragonez GC, Machado PS, Borges ALS, Pereira GKR, Valandro LF, Rippe MP. High-versus low-viscosity resin cements: Its effect on the load-bearing capacity under fatigue of a translucent zirconia. J Mech Behav Biomed Mater 2023; 142:105829. [PMID: 37068429 DOI: 10.1016/j.jmbbm.2023.105829] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/28/2023] [Accepted: 04/02/2023] [Indexed: 04/05/2023]
Abstract
The purpose of the present study was to characterize the elastic modulus and Poisson's ratio of a resin cement with distinct viscosities, and to evaluate their impact on the static and fatigue strength of a translucent zirconia (4Y-PSZ) after air-abrasion surface treatment. Bar-shaped specimens of two different viscosities of resin cement (high and low) were obtained (25 × 10 × 3 mm). Sonelastic and Maxwell principles tests were performed to determine the elastic modulus and Poisson's ratio of each resin cement. Disc-shaped specimens of 4Y-PSZ were made (Ø = 15 mm, 1.2 mm in thickness) for the mechanical tests and allocated into groups according to two factors: surface treatment (presence or absence of air-abrasion with alumina particles; 45 μm grain-size); cement (absence, low or high viscosity). The static (n = 10) and cyclical (n = 15) biaxial flexural strength tests were performed by piston-on-three-balls geometry. A fatigue strength test was executed (20 Hz, initial stress of 60 MPa [12% of the mean static biaxial flexural strength], followed by increments of 25 MPa [5% of the mean static biaxial flexural strength] at each step of 10,000 cycles until the failure). The obtained data were analyzed by Weibull analysis. Survival rates were tabulated by the Kaplan-Meier test. Complementary analyses of surface roughness, topography, cross-sectional interfacial zone, fractography, and zirconia crystalline content (X-ray diffraction) were also performed. The evaluated resin cements with high and low viscosity presented similar elastic modulus (13.63 GPa; 12.74 GPa) and Poisson's ratio (0.32; 0.30), respectively. The air-abraded groups depicted higher mechanical strength of the zirconia ceramics than non-abraded groups (p˂ 0.05), regardless of the resin cement. 4Y-PSZ adhesively bonded to a high or low viscosity resin cement have statistically similar behavior (p˃ 0.05). The mechanical structural reliability of the 4Y-PSZ was not affected by the factors. Therefore, resin cement with high and low viscosity presented similar properties and potential to fill the zirconia surface, and did not affect the mechanical behavior of 4Y-PSZ. However, the air-abrasion surface treatment increased the static and fatigue flexural strength of the translucent zirconia.
Collapse
|
13
|
Mechanical Properties of Translucent Zirconia: An In Vitro Study. PROSTHESIS 2023. [DOI: 10.3390/prosthesis5010004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Background: The introduction of translucent zirconia has improved mimetics: nevertheless, a reduction in the mechanical performance was registered. The study aim was to investigate the mechanical characteristics of a high-translucent zirconia used for monolithic restorations before and after the aging process compared to a low-translucent zirconia. Methods: A total of 23 specimens were used in the present study. Group A (n = 10) was made of a high-translucent Y-TZP; group B (n = 7) was made of a low-translucent Y-TZP and finally group C (n = 6) was an aged high-translucent Y-TZP. Flexural strength, fracture toughness, brittleness, microcrack’s propagation and grain size were analyzed. Results: The Vickers hardness was: 1483 ± 187 MPa (group C); 1102 ± 392 MPa (group A); 1284 ± 32 MPa (group B). The flexural strength was: 440 (±96.2) MPa (group C); 427 (±59.5) MPa (group A); 805 (±198.4) MPa (group B). The fracture toughness was: 5.1 (±0.7) MPa.m1/2 (group C); 4.9 (±0.9) MPa.m1/2 (group A); 8.9 (±1.1) MPa.m1/2 (group B). The brittleness was: 295 (±42.8) (group C), 230.9 (±46.4) (group A) and 144.9 (±20.3) (group B). The grain size was: 2.75 (±1.2) µm2 (group A); 0.16 (±0.05) µm2 (group B); 3.04 (±1.1) µm2 (group C). Conclusions: The significant reduction in the mechanical properties of high-translucent zirconia, compared to the traditional one, suggests their use in the anterior/lateral area (up to premolars).
Collapse
|
14
|
Kongkiatkamon S, Peampring C. Comparison of Regular and Speed Sintering on Low-Temperature Degradation and Fatigue Resistance of Translucent Zirconia Crowns for Implants: An In Vitro Study. J Funct Biomater 2022; 13:jfb13040281. [PMID: 36547541 PMCID: PMC9785840 DOI: 10.3390/jfb13040281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/22/2022] [Accepted: 12/04/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Although there are a few studies which compare fast and slow sintering in normal zirconia crowns, it is essential to compare the cracks and load-bearing capacity in zirconia screw-retained implant crowns between regular and speed sintering protocols. This research aimed to compare the surface structure, cracks, and load-bearing capacity in zirconia screw-retained implant crowns between regular sintering (RS) and speed sintering (SS) protocol with and without cyclic loading (fatigue). METHODS A total of 60 screw-retained crowns were fabricated from zirconia (Katana STML Block) by the CAD/CAM system. Then, 30 crowns were subjected to the RS protocol and 30 crowns were subjected to the SS protocol. Cyclic loading was done in half zirconia crowns (15 crowns in each group) using a chewing simulator CS-4.8/CS-4.4 at room temperature. The loading force was applied on the middle of the crowns by a metal stylus underwater at room temperature with a chewing simulator at an axial 50 N load for 240,000 cycles and lateral movement at 2 mm. Scanning electron microscopy was done to study the surface of the crowns and the cracks in the crowns of the regular and speed sintering protocols, with and without fatigue. RESULTS For the speed sintering group, the surface looks more uniform, and the crack lines are present at a short distance compared to regular sintering. The sintering protocol with a larger Weibull module and durability increases the reliability. It showed that the Speed group showed the maximum fracture load, followed by the regular, speed fatigue, and regular fatigue groups. The fracture load in various groups showed significant differences. CONCLUSIONS It was found that the speed group showed the maximum fracture load followed by the regular, speed fatigue, and regular fatigue. The crack lines ran from occlusal to bottoms (gingiva) and the arrest lines were perpendicular to the crack propagations.
Collapse
|
15
|
Miura S, Shinya A, Koizumi H, Fujisawa M. Effect of speed sintering of monolithic zirconia with different yttria contents on color and crystal phase. Eur J Oral Sci 2022; 130:e12898. [PMID: 36335285 DOI: 10.1111/eos.12898] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Accepted: 09/28/2022] [Indexed: 11/09/2022]
Abstract
This study evaluated the color and microstructure of monolithic zirconia crowns with different yttrium oxide (Y2 O3 ) contents treated by conventional or speed sintering. Four types of zirconia ceramics were assessed: two monolayer zirconia, and two multilayer zirconia. The monolithic zirconia crowns were fabricated using a dental computer-aided design/computer-aided manufacturing (CAD/CAM) system and in two shades (A2 and BL). After milling, the zirconia crowns were sintered using either speed sintering or conventional sintering. For each combination of zirconia (4), shade (2), and sintering condition (2), the color parameters were determined at three positions of each of nine crowns using a non-contact dental spectrophotometer. In addition, the zirconia phases in the specimens were quantified using X-ray diffractometry. Significant differences in the ΔE00 values at different measurement positions were observed for the Multi2 crown of the BL shade group. The color difference resulting from conventional and speed sintering programs was not affected by the difference in yttria content of Mono1, Mono2, and Multi1. However, in Multi2, containing 3Y-TZP and 5Y-PSZ, a color change was caused by the use of speed sintering. Therefore, when performing speed sintering with Multi2, it is necessary to select the color in consideration of these results or take measures for staining.
Collapse
Affiliation(s)
- Shoko Miura
- Division of Fixed Prosthodontics, Department of Restorative & Biomaterials Sciences, Meikai University School of Dentistry, Sakado, Saitama, Japan
| | - Akikazu Shinya
- Department of Dental Materials Sciences, School of Life Dentistry at Tokyo, The Nippon Dental University, Tokyo, Japan.,Department of Prosthetic Dentistry and Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland
| | - Hiroyasu Koizumi
- Department of Dental Materials, Nihon University School of Dentistry, Tokyo, Japan
| | - Masanori Fujisawa
- Division of Fixed Prosthodontics, Department of Restorative & Biomaterials Sciences, Meikai University School of Dentistry, Sakado, Saitama, Japan
| |
Collapse
|
16
|
Conventional, Speed Sintering and High-Speed Sintering of Zirconia: A Systematic Review of the Current Status of Applications in Dentistry with a Focus on Precision, Mechanical and Optical Parameters. J Clin Med 2022; 11:jcm11164892. [PMID: 36013131 PMCID: PMC9409711 DOI: 10.3390/jcm11164892] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 08/04/2022] [Accepted: 08/17/2022] [Indexed: 01/17/2023] Open
Abstract
The aim of this systematic review was to provide an overview of the technical and clinical outcomes of conventional, speed sintering and high-speed sintering protocols of zirconia in the dental field. Data on precision, mechanical and optical parameters were evaluated and related to the clinical performance of zirconia ceramic. The PICOS search strategy was applied using MEDLINE to search for in vitro and in vivo studies using MeSH Terms by two reviewers. Of 66 potentially relevant studies, 5 full text articles were selected and 10 were further retrieved through a manual search. All 15 studies included in the systematic review were in vitro studies. Mechanical, precision and optical properties (marginal and internal fit, fracture strength and modulus, wear, translucency and opalescence, aging resistance/hydrothermal aging) were evaluated regarding 3-, 4- and 5-YTZP zirconia material and conventional, high- and high-speed sintering protocols. Mechanical and precision results were similar or better when speed or high-speed sintering methods were used for 3-, 4- and 5-YTZP zirconia. Translucency is usually reduced when 3 Y-TZP is used with speed sintering methods. All types of zirconia using the sintering procedures performed mechanically better compared to lithium disilicate glass ceramics but glass ceramics showed better results regarding translucency.
Collapse
|
17
|
Mayinger F, Buser R, Laier M, Schönhoff LM, Kelch M, Hampe R, Stawarczyk B. Impact of the material and sintering protocol, layer thickness, and thermomechanical aging on the two-body wear and fracture load of 4Y-TZP crowns. Clin Oral Investig 2022; 26:6617-6628. [PMID: 35840737 DOI: 10.1007/s00784-022-04616-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 07/04/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES The aim of this study is to investigate the influence of the material and corresponding sintering protocol, layer thickness, and aging on the two-body wear (2BW) and fracture load (FL) of 4Y-TZP crowns. MATERIALS AND METHODS Multi-layer 4Y-TZP crowns in three thicknesses (0.5 mm/1.0 mm/1.5 mm) were sintered by high-speed (Zolid RS) or conventional (Zolid Gen-X) sintering. 2BW of ceramic and enamel antagonist after aging (1,200,000 mechanical-, 6000 thermal-cycles) was determined by 3D-scanning before and after aging and subsequent matching to determine volume and height loss (6 subgroups, n = 16/subgroup). FL was examined initially and after aging (12 subgroups, n = 16/subgroup). Fractographic analyses were performed using light-microscope imaging. Global univariate analysis of variance, one-way ANOVA, linear regression, Spearman's correlation, Kolgomorov-Smirnov, Mann-Whitney U, and t test were computed (alpha = 0.05). Weibull moduli were determined. Fracture types were analyzed using Ciba Geigy table. RESULTS Material/sintering protocol did not influence 2BW (crowns: p = 0.908, antagonists: p = 0.059). High-speed sintered Zolid RS presented similar (p = 0.325-0.633) or reduced (p < 0.001-0.047) FL as Zolid Gen-X. Both 4Y-TZPs showed an increased FL with an increasing thickness (0.5(797.3-1429 N) < 1.0(2087-2634 N) < 1.5(2683-3715 N)mm; p < 0.001). For most groups, aging negatively impacted FL (p < 0.001-0.002). Five 0.5 mm specimens fractured, four showed cracks during and after aging. CONCLUSIONS High-speed sintered crowns with a minimum thickness of 1.0 mm showed sufficient mechanical properties to withstand masticatory forces, even after a simulated aging period of 5 years. CLINICAL RELEVANCE Despite the manufacturer indicating a thickness of 0.5 mm to be suitable for single crowns, a minimum thickness of 1.0 mm should be used to ensure long-term satisfactory results.
Collapse
Affiliation(s)
- Felicitas Mayinger
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Ramona Buser
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.,Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007, Bern, Switzerland
| | - Maximilian Laier
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Lisa Marie Schönhoff
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Matthias Kelch
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Rüdiger Hampe
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
18
|
Multilayer Super-Translucent Zirconia for Chairside Fabrication of a Monolithic Posterior Crown. Case Rep Dent 2022; 2022:4474227. [PMID: 35371572 PMCID: PMC8967591 DOI: 10.1155/2022/4474227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 03/07/2022] [Indexed: 11/17/2022] Open
Abstract
This case report describes the chairside fabrication of a monolithic posterior crown using a multilayer super-translucent zirconia material. According to the manufacturer’s information, the newly introduced multilayer zirconia (4-YTZP) offers a unique combination of fracture strength (>850 MPa with speed-sintering) and improved optical properties, thus allowing a reduced minimum material thickness and optional temporary luting. By using up-to-date components of the CEREC system, including superfast dry-milling and a speed-sintering process, the fabrication of a monolithic zirconia crown is possible within an acceptable timeframe for the chairside workflow (60-75 min). The usage of a multilayer super-translucent material allows for the individualization of the restoration, typically in a single combined stain and glaze firing. However, it should be noted that clinical data for this type of restoration are still sparse. Therefore, manufacturer recommendations regarding indication, preparation, and cementation must be followed very strictly.
Collapse
|
19
|
New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies. BIOMED RESEARCH INTERNATIONAL 2022; 2022:3074182. [PMID: 35281596 PMCID: PMC8906986 DOI: 10.1155/2022/3074182] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 01/05/2022] [Accepted: 02/02/2022] [Indexed: 12/31/2022]
Abstract
Innovations in digital manufacturing enabled the fabrication of implant-supported fixed dental prostheses (ISFDPs) in a wide variety of recently introduced materials. Computer-aided design and computer-aided manufacturing (CAD-CAM) milling allows the fabrication of ISFDPs with high accuracy by reducing the fabrication steps of large-span frameworks. The longevity of ISFDPs depends on the overall mechanical properties of the framework material including its fit, and the physical properties of the veneering material and its bond with the framework. This comprehensive review summarizes the recent information on millable CAD-CAM framework materials such as pre-sintered soft alloys, fiber-reinforced composite resins, PEEK, and PEKK in high-performance polymer family, and 4Y-TZP. Even though promising results have been obtained with the use of new generation millable CAD-CAM materials for ISFDPs, clinical studies are lacking and future research should focus on the overall performance of these millable materials in both static and dynamic conditions.
Collapse
|
20
|
Influence of high-speed sintering protocols on translucency, mechanical properties, microstructure, crystallography, and low-temperature degradation of highly translucent zirconia. Dent Mater 2021; 38:451-468. [PMID: 34961644 DOI: 10.1016/j.dental.2021.12.028] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 12/15/2021] [Accepted: 12/15/2021] [Indexed: 01/24/2023]
Abstract
OBJECTIVES Impacts of high-speed sintering on the optical and mechanical properties, microstructure, crystallography, and low-temperature degradation of commercial yttria-partially stabilized zirconia (Y-PSZ) were investigated. METHODS Five commercial Y-PSZ products (KATANA HT, KATANA STML, KATANA UTML, Zpex 4, and Zpex Smile) were investigated. Specimens were sintered following speed-sintering (~90 min) and conventional-sintering protocols (~7 h), and a group of KATANA STML was super-speed-sintered (18 min). Dimensions of the zirconia specimens after sintering were 14.5 mm (diameter) and 1.2 mm (thickness). Translucency was assessed using a colorimeter. Biaxial flexural strength was measured using a universal testing machine, followed by Weibull analysis. Scanning electron microscopy was used for microstructure assessments. X-ray diffraction was used to analyze the crystallography before and after hydrothermal aging. Low-temperature degradation (LTD) tests were performed at 134 °C under 2-3 bar water vapor in an autoclave. RESULTS The translucency and flexural strength were not affected significantly by the sintering programs (p > 0.05). The conventionally sintered KATANA STML and speed-sintered Zpex 4 presented the highest and lowest Weibull modulus, respectively. The conventionally-sintered Y-PSZ had a larger average grain size and smaller fraction of fine grains than those of the speed-sintered specimens. The fractographic analysis of the speed- and conventionally sintered Y-PSZ yielded comparable results. The speed-sintered Y-PSZ exhibited a lower c-ZrO2 content than that of conventionally-sintered Y-PSZ, except for KATANA HT and KATANA STML. LTD tests indicated that some of the speed and conventionally-sintered Y-PSZ exhibited similar monoclinic volume fractions. SIGNIFICANCE Speed-sintering programs are acceptable for Y-PSZ zirconia.
Collapse
|
21
|
Mühlemann S, Hjerppe J, Hämmerle CHF, Thoma DS. Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review. Clin Oral Implants Res 2021; 32 Suppl 21:289-302. [PMID: 34642980 PMCID: PMC9293467 DOI: 10.1111/clr.13801] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 04/16/2021] [Accepted: 06/10/2021] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To systematically review the dental literature for clinical studies reporting on production time, effectiveness and/or costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses. MATERIALS AND METHODS A systematic electronic search for clinical studies from 1990 until June 2020 was performed using the online databases Medline, Embase and Cochrane. Time required for the computer-aided design (CAD) process, the CAM process, and the delivery of the CAD-CAM prostheses were extracted. In addition, articles reporting on the effectiveness and the costs of both manufacturing technologies were included. RESULTS Nine clinical studies were included reporting on subtractive CAM (s-CAM; 8 studies) and additive CAM (a-CAM; 1 study). Eight studies reported on the s-CAM of prosthetic and auxiliary components for single implant crowns. One study applied a-CAM for the fabrication of an implant bar prototype. Time was provided for the CAD process of implant models (range 4.9-11.8 min), abutments (range 19.7-32.7 min) and crowns (range 11.1-37.6 min). The time for s-CAM of single implant crown components (abutment/crown) ranged between 8.2 and 25 min. Post-processing (e.g. sintering) was a time-consuming process (up to 530 min). At delivery, monolithic/veneered CAD-CAM implant crowns resulted in additional adjustments chairside (51%/93%) or labside (11%/19%). CONCLUSIONS No scientific evidence exists on production time, effectiveness and costs of digital workflows comparing s-CAM and a-CAM. For both technologies, post-processing may substantially contribute to the production time. Considering effectiveness, monolithic CAD-CAM implant crowns may be preferred compared to veneered CAD-CAM crowns.
Collapse
Affiliation(s)
- Sven Mühlemann
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Jenni Hjerppe
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Christoph H F Hämmerle
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Daniel S Thoma
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
22
|
Wertz M, Hoelzig H, Kloess G, Hahnel S, Koenig A. Influence of Manufacturing Regimes on the Phase Transformation of Dental Zirconia. MATERIALS 2021; 14:ma14174980. [PMID: 34501071 PMCID: PMC8434073 DOI: 10.3390/ma14174980] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/26/2021] [Accepted: 08/29/2021] [Indexed: 11/23/2022]
Abstract
Background: The influence of typical manufacturing regimes for producing fixed dental prostheses (FDPs) from yttria partly-stabilized zirconia polycrystals (3Y/4Y/5Y-TZP) on the phase composition is quantified. Methods: Fixed dental prostheses (FDPs) were designed using a CAD process and machined from different Y-TZP blanks from two manufacturers differing in yttria contents. Subsequent to sintering, the FDPs were glaze fired and air-blasted using alumina particles. Phase composition was determined with X-ray diffraction and quantified with Rietveld refinement. Results: The blanks from VITA Zahnfabrik (VITA YZ HT, VITA YZ ST, VITA YZ XT) and Dental Direct (DD Bio ZX2, DD cube ONE, DD cube X2) featured a rhombohedral portion with rather small crystallites and a small monoclinic portion for 3Y/4Y-TZPs, which increased after machining and disappeared after sintering. Glaze firing and air-blasting with alumina particles had no significant influence on the phase composition. Conclusion: The phase history of dental zirconia is revealed, which may have implications on further processing and aging of the FDP (e.g. low temperature degradation) in mouth.
Collapse
Affiliation(s)
- Markus Wertz
- Department of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany; (M.W.); (S.H.)
| | - Hieronymus Hoelzig
- Institute of Mineralogy, Crystallography and Materials Science, Leipzig University, 04103 Leipzig, Germany; (H.H.); (G.K.)
| | - Gert Kloess
- Institute of Mineralogy, Crystallography and Materials Science, Leipzig University, 04103 Leipzig, Germany; (H.H.); (G.K.)
| | - Sebastian Hahnel
- Department of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany; (M.W.); (S.H.)
| | - Andreas Koenig
- Department of Prosthodontics and Material Sciences, Leipzig University, 04103 Leipzig, Germany; (M.W.); (S.H.)
- Correspondence:
| |
Collapse
|
23
|
Jeong KW, Yoon HI, Lee JH, Yeo ISL, Kim DJ, Han JS. Clinical Feasibility of Fully Sintered (Y, Nb)-TZP for CAD-CAM Single-Unit Restoration: A Pilot Study. MATERIALS 2021; 14:ma14112762. [PMID: 34071077 PMCID: PMC8197114 DOI: 10.3390/ma14112762] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 04/24/2021] [Accepted: 05/21/2021] [Indexed: 11/16/2022]
Abstract
Fifteen participants (9 male, 6 female) received a total of 15 monolithic single restorations made from fully sintered (Y, Nb)-TZP (tetragonal zirconia polycrystal) block. The restorations were clinically evaluated for survival, success rate, and periodontal probing depths 6 months after the insertion of the restorations. Esthetic, functional, and biological evaluations were also performed over a 6-month follow-up period. The survival and success rates of the single-unit restorations were 100%. The periodontal probing depth values ranged from 1 to 3 mm. No complications with regard to functional and biological properties were observed after 6 months. The postoperative sensitivity was only a transient phenomenon. The fully sintered (Y, Nb)-TZP single-unit restoration showed highly acceptable quality with successful clinical performance over 6 months.
Collapse
Affiliation(s)
- Ki-Won Jeong
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; (K.-W.J.); (J.-H.L.); (I.-S.L.Y.); (J.-S.H.)
| | - Hyung-In Yoon
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; (K.-W.J.); (J.-H.L.); (I.-S.L.Y.); (J.-S.H.)
- Correspondence: ; Tel.: +82-2-2072-4472
| | - Jae-Hyun Lee
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; (K.-W.J.); (J.-H.L.); (I.-S.L.Y.); (J.-S.H.)
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; (K.-W.J.); (J.-H.L.); (I.-S.L.Y.); (J.-S.H.)
| | - Dae-Joon Kim
- Department of Dentistry, VASIC Research Center, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea;
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul 03080, Korea; (K.-W.J.); (J.-H.L.); (I.-S.L.Y.); (J.-S.H.)
| |
Collapse
|
24
|
Cotič J, Kocjan A, Panchevska S, Kosmač T, Jevnikar P. In vivo ageing of zirconia dental ceramics - Part II: Highly-translucent and rapid-sintered 3Y-TZP. Dent Mater 2020; 37:454-463. [PMID: 33376028 DOI: 10.1016/j.dental.2020.11.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 11/27/2020] [Accepted: 11/27/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE 3Y-TZP ceramics with reduced alumina content have improved translucency and are used in monolithic dental restorations without porcelain-based veneers. The workflow can be further streamlined with rapid sintering. This study was designed to assess how these approaches affect ageing when the materials are exposed to the oral environment in vivo. METHODS 43 discs were fabricated from 3Y-TZP powder with 0.05% Al2O3 and sintered with conventional or rapid regimens (1450 °C 2 h, 1530 °C 2 h, or 1530 °C 25 min). Their surfaces were polished or airborne-particle abraded with 50 μm Al2O3. The discs were incorporated in complete dentures of 16 volunteers and worn continuously for up to 48 months. Ageing changes on disc surfaces were monitored every 6 months by X-ray diffraction, scanning electron microscopy and atomic force microscopy. Data was statistically analysed with linear models. RESULTS The amount of monoclinic phase on polished surfaces increased linearly, reaching up to 40% after 48 months in vivo. The ageing process observed for rapid sintering was 1.6 times faster compared to conventional sintering. A nano-scale increase in roughness with microcracking was also detected on polished surfaces. Airborne-particle abraded surfaces did not exhibit clear signs of ageing during the course of the study. SIGNIFICANCE Highly-translucent 3Y-TZP ceramics are more susceptible to ageing than classic 3Y-TZP. After 4 years in vivo, the extent of degradation did not yet constitute grounds for clinical concern, but was more pronounced in materials prepared with rapid sintering.
Collapse
Affiliation(s)
- Jasna Cotič
- Department of Prosthodontics, Faculty of Medicine, University of Ljubljana, Hrvatski Trg 6, SI-1000 Ljubljana, Slovenia
| | - Andraž Kocjan
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Sanja Panchevska
- Faculty of Dentistry, Ss. Cyril and Methodius University, Majka Tereza 43, MK-1000 Skopje, Republic of North Macedonia
| | - Tomaž Kosmač
- Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Peter Jevnikar
- Department of Prosthodontics, Faculty of Medicine, University of Ljubljana, Hrvatski Trg 6, SI-1000 Ljubljana, Slovenia.
| |
Collapse
|